National Test House, Alipore, Kolkata-700027
| IS 1180 : Part 1 (2014) |
Outdoor Type Oil Immersed Distribution Transformers Upto and Including 2 500 kVA, 33kV - Specification Part 1 Mineral Oil Immersed (Fourth Revision) |
- |
-
|
45000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
13.1(Marking (Rating Plates)) |
- |
1000 |
|
- |
13.2(Terminal Marking Plate) |
- |
0 |
|
- |
13.3(Marking ) |
- |
1000 |
|
- |
13.4(Marking) |
- |
1000 |
|
- |
13.4.1(Marking) |
- |
1000 |
|
- |
21.2 a)(Measurement of winding resistance ) |
- |
1000 |
|
- |
21.2 b)( Measurement of voltage ratio and check of
phase displacemen) |
- |
1500 |
|
- |
21.2 c)( Measurement of short-circuit impedance
(principal tapping, when applicable) and load
loss at 50 percent and 100 percent load) |
- |
6000 |
|
- |
21.2 d)(Measurement of no-load loss and current) |
- |
5500 |
|
- |
21.2 e)(Measurement of insulation resistance) |
- |
1000 |
|
- |
21.2 f)(Induced over-voltage withstand test) |
- |
2500 |
|
- |
21.2 g)( Separate-source voltage withstand test) |
- |
2500 |
|
- |
21.5.3.3(Oil leakage test) |
- |
7000 |
|
- |
21.3(b)(Temperature-rise test) |
- |
30000 |
|
- |
21.4 a)( Determination of sound levels) |
- |
6000 |
|
- |
21.5.1.1(Pressure test-Type test (For Transformers up to 200 kVA
)) |
- |
10000 |
|
- |
21.5.1.2(Pressure test-routine test (For Transformers up to 200 kVA
)) |
- |
5000 |
|
- |
21.5.2.1(Type test : For Transformers Above 200 kVA and Up to Including 2 500 kVA) |
- |
10000 |
|
- |
21.5.2.2(routine test :For Transformers Above 200 kVA and Up to Including 2 500 kVA) |
- |
5000 |
|
- |
21.5.2.3( Oil leakage test (routine test)) |
- |
7000 |
|
- |
21.5.3.1(For Single Phase Distribution Transformers Up to Including 25 kVA : pressure test (type test)) |
- |
5000 |
|
- |
21.5.3.2(For Single Phase Distribution Transformers Up to Including 25 kVA : pressure test (routine test)) |
- |
5000 |
|
- |
21.4 c(No load current at 112.5 percent voltage.) |
- |
2000 |
|
- |
21.4 d(Paint adhesion tests) |
- |
5000 |
|
- |
6.9, 7.9, 8.9(Permissible Flux Density and Over Fluxing) |
- |
10000 |
|
- |
11(Minimum clearance in Air) |
- |
1000 |
|
- |
21.5.1.3(Oil leakage test upto 200 KVA) |
- |
7000 |
|
- |
6.8 (50%)(Total losses at 50 % load (Watts)) |
- |
0 |
|
- |
7.8 (50%)(Total losses at 50 % load (Watts)) |
- |
0 |
|
- |
8.8 (50%)(Total losses at 50 % load (Watts)) |
- |
0 |
|
- |
6.8 (100%)(Total losses at 100 % load (Watts)) |
- |
0 |
|
- |
7.8 (100%)(Total losses at 100 % load (Watts)) |
- |
0 |
|
- |
8.8 (100%)(Total losses at 100 % load (Watts)) |
- |
0 |
|
- |
21.5.3.3(Oil leakage test (routine test)) |
- |
7000 |
|
- |
6.9(Permissible Flux Density and Over Fluxing ) |
- |
10000 |
|
- |
6.1(Limits of Temperature-rise) |
- |
30000 |
|
- |
11(Minimum Clearnaces air ) |
- |
1000 |
|
- |
13.1(Marking (Rating Plates)) |
- |
1000 |
|
- |
13.2(Terminal Marking Plate) |
- |
0 |
|
- |
13.3(Marking ) |
- |
1000 |
|
- |
13.4(Marking) |
- |
1000 |
|
- |
13.4.1(Marking) |
- |
1000 |
|
- |
21.2 a)(Measurement of winding resistance ) |
- |
1000 |
|
- |
21.2 b)( Measurement of voltage ratio and check of
phase displacemen) |
- |
1500 |
|
- |
21.2 c)( Measurement of short-circuit impedance
(principal tapping, when applicable) and load
loss at 50 percent and 100 percent load) |
- |
6000 |
|
- |
21.2 d)(Measurement of no-load loss and current) |
- |
5500 |
|
- |
21.2 e)(Measurement of insulation resistance) |
- |
1000 |
|
- |
21.2 f)(Induced over-voltage withstand test) |
- |
2500 |
|
- |
21.2 g)( Separate-source voltage withstand test) |
- |
2500 |
|
- |
21.5.3.3(Oil leakage test) |
- |
7000 |
|
- |
21.3(b)(Temperature-rise test) |
- |
30000 |
|
- |
21.4 a)( Determination of sound levels) |
- |
6000 |
|
- |
21.5.1.1(Pressure test-Type test (For Transformers up to 200 kVA
)) |
- |
10000 |
|
- |
21.5.1.2(Pressure test-routine test (For Transformers up to 200 kVA
)) |
- |
5000 |
|
- |
21.5.2.1(Type test : For Transformers Above 200 kVA and Up to Including 2 500 kVA) |
- |
10000 |
|
- |
21.5.2.2(routine test :For Transformers Above 200 kVA and Up to Including 2 500 kVA) |
- |
5000 |
|
- |
21.5.2.3( Oil leakage test (routine test)) |
- |
7000 |
|
- |
21.5.3.1(For Single Phase Distribution Transformers Up to Including 25 kVA : pressure test (type test)) |
- |
5000 |
|
- |
21.5.3.2(For Single Phase Distribution Transformers Up to Including 25 kVA : pressure test (routine test)) |
- |
5000 |
|
- |
21.4 c(No load current at 112.5 percent voltage.) |
- |
2000 |
|
- |
21.4 d(Paint adhesion tests) |
- |
5000 |
|
- |
6.9, 7.9, 8.9(Permissible Flux Density and Over Fluxing) |
- |
10000 |
|
- |
11(Minimum clearance in Air) |
- |
1000 |
|
- |
21.5.1.3(Oil leakage test upto 200 KVA) |
- |
7000 |
|
- |
6.8 (50%)(Total losses at 50 % load (Watts)) |
- |
0 |
|
- |
7.8 (50%)(Total losses at 50 % load (Watts)) |
- |
0 |
|
- |
8.8 (50%)(Total losses at 50 % load (Watts)) |
- |
0 |
|
- |
6.8 (100%)(Total losses at 100 % load (Watts)) |
- |
0 |
|
- |
7.8 (100%)(Total losses at 100 % load (Watts)) |
- |
0 |
|
- |
8.8 (100%)(Total losses at 100 % load (Watts)) |
- |
0 |
|
- |
21.5.3.3(Oil leakage test (routine test)) |
- |
7000 |
|
- |
6.9(Permissible Flux Density and Over Fluxing ) |
- |
10000 |
|
- |
6.1(Limits of Temperature-rise) |
- |
30000 |
|
- |
11(Minimum Clearnaces air ) |
- |
1000 |
|
- |
13.1(Marking (Rating Plates)) |
- |
1000 |
|
- |
13.2(Terminal Marking Plate) |
- |
1000 |
|
- |
13.3(Marking ) |
- |
1000 |
|
- |
13.4(Marking) |
- |
1000 |
|
- |
13.4.1(Marking) |
- |
1000 |
|
- |
21.2 a)(Measurement of winding resistance ) |
- |
1000 |
|
- |
21.2 b)( Measurement of voltage ratio and check of
phase displacemen) |
- |
1500 |
|
- |
21.2 c)( Measurement of short-circuit impedance
(principal tapping, when applicable) and load
loss at 50 percent and 100 percent load) |
- |
6000 |
|
- |
21.2 d)(Measurement of no-load loss and current) |
- |
5500 |
|
- |
21.2 e)(Measurement of insulation resistance) |
- |
1000 |
|
- |
21.2 f)(Induced over-voltage withstand test) |
- |
2500 |
|
- |
21.2 g)( Separate-source voltage withstand test) |
- |
2500 |
|
- |
21.5.3.3(Oil leakage test) |
- |
7000 |
|
- |
21.3(b)(Temperature-rise test) |
- |
30000 |
|
- |
21.4 a)( Determination of sound levels) |
- |
6000 |
|
- |
21.5.1.1(Pressure test-Type test (For Transformers up to 200 kVA
)) |
- |
10000 |
|
- |
21.5.1.2(Pressure test-routine test (For Transformers up to 200 kVA
)) |
- |
5000 |
|
- |
21.5.2.1(Type test : For Transformers Above 200 kVA and Up to Including 2 500 kVA) |
- |
10000 |
|
- |
21.5.2.2(routine test :For Transformers Above 200 kVA and Up to Including 2 500 kVA) |
- |
5000 |
|
- |
21.5.2.3( Oil leakage test (routine test)) |
- |
7000 |
|
- |
21.5.3.1(For Single Phase Distribution Transformers Up to Including 25 kVA : pressure test (type test)) |
- |
5000 |
|
- |
21.5.3.2(For Single Phase Distribution Transformers Up to Including 25 kVA : pressure test (routine test)) |
- |
5000 |
|
- |
21.4 c(No load current at 112.5 percent voltage.) |
- |
2000 |
|
- |
21.4 d(Paint adhesion tests) |
- |
5000 |
|
- |
6.9, 7.9, 8.9(Permissible Flux Density and Over Fluxing) |
- |
10000 |
|
- |
11(Minimum clearance in Air) |
- |
1000 |
|
- |
21.5.1.3(Oil leakage test upto 200 KVA) |
- |
7000 |
|
- |
6.8 (50%)(Total losses at 50 % load (Watts)) |
- |
0 |
|
- |
7.8 (50%)(Total losses at 50 % load (Watts)) |
- |
0 |
|
- |
8.8 (50%)(Total losses at 50 % load (Watts)) |
- |
0 |
|
- |
6.8 (100%)(Total losses at 100 % load (Watts)) |
- |
0 |
|
- |
7.8 (100%)(Total losses at 100 % load (Watts)) |
- |
0 |
|
- |
8.8 (100%)(Total losses at 100 % load (Watts)) |
- |
0 |
|
- |
21.5.3.3(Oil leakage test (routine test)) |
- |
7000 |
|
- |
6.9(Permissible Flux Density and Over Fluxing ) |
- |
10000 |
|
- |
6.1(Limits of Temperature-rise) |
- |
30000 |
|
- |
11(Minimum Clearnaces air ) |
- |
1000 |
|
- |
|
Complete
|
|
08 Apr, 2027 |
- Included.w.e.f.16.01.2025 |
2 |
DELHI TEST HOUSE KUNDLI-2
| IS 1180 : Part 1 (2014) |
Outdoor Type Oil Immersed Distribution Transformers Upto and Including 2 500 kVA, 33kV - Specification Part 1 Mineral Oil Immersed (Fourth Revision) |
2500KVA |
-
|
208000 View breakup
For BIS Samples – 1.5 times the BIS testing charges. For others : Rs.35,000/-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
21.5.3.1(For Single Phase Distribution Transformers Up to Including 25 kVA : pressure test (type test)) |
- |
3500 |
|
Above 500KVA to 2500KVA Total Testing Charges: Rs 2.08L(For Routine test : Rs 37K) Above 100KVA to 500KVA Total Testing Charges: Rs 1.144L(For Routine test: Rs 30K) Single & 3 Phase Up to100KVA Total Testing Charges :Rs 8.944K (For Routine test: Rs 25K) |
21.5.3.2(For Single Phase Distribution Transformers Up to Including 25 kVA : pressure test (routine test)) |
- |
3500 |
|
Above 500KVA to 2500KVA Total Testing Charges: Rs 2.08L(For Routine test : Rs 37K) Above 100KVA to 500KVA Total Testing Charges: Rs 1.144L(For Routine test: Rs 30K) Single & 3 Phase Up to100KVA Total Testing Charges :Rs 8.944K (For Routine test: Rs 25K) |
21.5.3.3(Oil leakage test (routine test)) |
- |
3500.00 |
|
Above 500KVA to 2500KVA Total Testing Charges: Rs 2.08L(For Routine test : Rs 37K) Above 100KVA to 500KVA Total Testing Charges: Rs 1.144L(For Routine test: Rs 30K) Single & 3 Phase Up to100KVA Total Testing Charges :Rs 8.944K (For Routine test: Rs 25K) |
13.1(Marking (Rating Plates)) |
- |
2000.00 |
|
Above 500KVA to 2500KVA Total Testing Charges: Rs 2.08L(For Routine test : Rs 37K) Above 100KVA to 500KVA Total Testing Charges: Rs 1.144L(For Routine test: Rs 30K) Single & 3 Phase Up to100KVA Total Testing Charges :Rs 8.944K (For Routine test: Rs 25K) |
13.2(Terminal Marking Plate) |
- |
2000.00 |
|
Above 500KVA to 2500KVA Total Testing Charges: Rs 2.08L(For Routine test : Rs 37K) Above 100KVA to 500KVA Total Testing Charges: Rs 1.144L(For Routine test: Rs 30K) Single & 3 Phase Up to100KVA Total Testing Charges :Rs 8.944K (For Routine test: Rs 25K) |
13.3(Marking ) |
- |
2000.00 |
|
Above 500KVA to 2500KVA Total Testing Charges: Rs 2.08L(For Routine test : Rs 37K) Above 100KVA to 500KVA Total Testing Charges: Rs 1.144L(For Routine test: Rs 30K) Single & 3 Phase Up to100KVA Total Testing Charges :Rs 8.944K (For Routine test: Rs 25K) |
13.4(Marking) |
- |
2000.00 |
|
Above 500KVA to 2500KVA Total Testing Charges: Rs 2.08L(For Routine test : Rs 37K) Above 100KVA to 500KVA Total Testing Charges: Rs 1.144L(For Routine test: Rs 30K) Single & 3 Phase Up to100KVA Total Testing Charges :Rs 8.944K (For Routine test: Rs 25K) |
13.4.1(Marking) |
- |
2000.00 |
|
Above 500KVA to 2500KVA Total Testing Charges: Rs 2.08L(For Routine test : Rs 37K) Above 100KVA to 500KVA Total Testing Charges: Rs 1.144L(For Routine test: Rs 30K) Single & 3 Phase Up to100KVA Total Testing Charges :Rs 8.944K (For Routine test: Rs 25K) |
14.1(MOUNTING ARRANGEMENT) |
- |
2000.00 |
|
Above 500KVA to 2500KVA Total Testing Charges: Rs 2.08L(For Routine test : Rs 37K) Above 100KVA to 500KVA Total Testing Charges: Rs 1.144L(For Routine test: Rs 30K) Single & 3 Phase Up to100KVA Total Testing Charges :Rs 8.944K (For Routine test: Rs 25K) |
14.2(MOUNTING ARRANGEMENT) |
- |
2000.00 |
|
Above 500KVA to 2500KVA Total Testing Charges: Rs 2.08L(For Routine test : Rs 37K) Above 100KVA to 500KVA Total Testing Charges: Rs 1.144L(For Routine test: Rs 30K) Single & 3 Phase Up to100KVA Total Testing Charges :Rs 8.944K (For Routine test: Rs 25K) |
14.3(MOUNTING ARRANGEMENT) |
- |
2000.00 |
|
Above 500KVA to 2500KVA Total Testing Charges: Rs 2.08L(For Routine test : Rs 37K) Above 100KVA to 500KVA Total Testing Charges: Rs 1.144L(For Routine test: Rs 30K) Single & 3 Phase Up to100KVA Total Testing Charges :Rs 8.944K (For Routine test: Rs 25K) |
14.4(MOUNTING ARRANGEMENT) |
- |
2000.00 |
|
Above 500KVA to 2500KVA Total Testing Charges: Rs 2.08L(For Routine test : Rs 37K) Above 100KVA to 500KVA Total Testing Charges: Rs 1.144L(For Routine test: Rs 30K) Single & 3 Phase Up to100KVA Total Testing Charges :Rs 8.944K (For Routine test: Rs 25K) |
15.1.1(TRANSFORMER TANK : Construction) |
- |
2000.00 |
|
Above 500KVA to 2500KVA Total Testing Charges: Rs 2.08L(For Routine test : Rs 37K) Above 100KVA to 500KVA Total Testing Charges: Rs 1.144L(For Routine test: Rs 30K) Single & 3 Phase Up to100KVA Total Testing Charges :Rs 8.944K (For Routine test: Rs 25K) |
15.1.2(TRANSFORMER TANK : Construction) |
- |
2000.00 |
|
Above 500KVA to 2500KVA Total Testing Charges: Rs 2.08L(For Routine test : Rs 37K) Above 100KVA to 500KVA Total Testing Charges: Rs 1.144L(For Routine test: Rs 30K) Single & 3 Phase Up to100KVA Total Testing Charges :Rs 8.944K (For Routine test: Rs 25K) |
15.1.3(TRANSFORMER TANK : Construction) |
- |
2000.00 |
|
Above 500KVA to 2500KVA Total Testing Charges: Rs 2.08L(For Routine test : Rs 37K) Above 100KVA to 500KVA Total Testing Charges: Rs 1.144L(For Routine test: Rs 30K) Single & 3 Phase Up to100KVA Total Testing Charges :Rs 8.944K (For Routine test: Rs 25K) |
15.1.4(TRANSFORMER TANK : Construction) |
- |
2000.00 |
|
Above 500KVA to 2500KVA Total Testing Charges: Rs 2.08L(For Routine test : Rs 37K) Above 100KVA to 500KVA Total Testing Charges: Rs 1.144L(For Routine test: Rs 30K) Single & 3 Phase Up to100KVA Total Testing Charges :Rs 8.944K (For Routine test: Rs 25K) |
15.1.5(TRANSFORMER TANK : Construction) |
- |
2000.00 |
|
Above 500KVA to 2500KVA Total Testing Charges: Rs 2.08L(For Routine test : Rs 37K) Above 100KVA to 500KVA Total Testing Charges: Rs 1.144L(For Routine test: Rs 30K) Single & 3 Phase Up to100KVA Total Testing Charges :Rs 8.944K (For Routine test: Rs 25K) |
21.2 a)(Measurement of winding resistance ) |
- |
4000.00 |
|
Above 500KVA to 2500KVA Total Testing Charges: Rs 2.08L(For Routine test : Rs 37K) Above 100KVA to 500KVA Total Testing Charges: Rs 1.144L(For Routine test: Rs 30K) Single & 3 Phase Up to100KVA Total Testing Charges :Rs 8.944K (For Routine test: Rs 25K) |
21.2 b)( Measurement of voltage ratio and check of
phase displacemen) |
- |
4000.00 |
|
Above 500KVA to 2500KVA Total Testing Charges: Rs 2.08L(For Routine test : Rs 37K) Above 100KVA to 500KVA Total Testing Charges: Rs 1.144L(For Routine test: Rs 30K) Single & 3 Phase Up to100KVA Total Testing Charges :Rs 8.944K (For Routine test: Rs 25K) |
21.2 c)( Measurement of short-circuit impedance
(principal tapping, when applicable) and load
loss at 50 percent and 100 percent load) |
- |
10000.00 |
|
Above 500KVA to 2500KVA Total Testing Charges: Rs 2.08L(For Routine test : Rs 37K) Above 100KVA to 500KVA Total Testing Charges: Rs 1.144L(For Routine test: Rs 30K) Single & 3 Phase Up to100KVA Total Testing Charges :Rs 8.944K (For Routine test: Rs 25K) |
21.2 d)(Measurement of no-load loss and current) |
- |
6000.00 |
|
Above 500KVA to 2500KVA Total Testing Charges: Rs 2.08L(For Routine test : Rs 37K) Above 100KVA to 500KVA Total Testing Charges: Rs 1.144L(For Routine test: Rs 30K) Single & 3 Phase Up to100KVA Total Testing Charges :Rs 8.944K (For Routine test: Rs 25K) |
21.2 e)(Measurement of insulation resistance) |
- |
4000.00 |
|
Above 500KVA to 2500KVA Total Testing Charges: Rs 2.08L(For Routine test : Rs 37K) Above 100KVA to 500KVA Total Testing Charges: Rs 1.144L(For Routine test: Rs 30K) Single & 3 Phase Up to100KVA Total Testing Charges :Rs 8.944K (For Routine test: Rs 25K) |
21.2 f)(Induced over-voltage withstand test) |
- |
7000.00 |
|
Above 500KVA to 2500KVA Total Testing Charges: Rs 2.08L(For Routine test : Rs 37K) Above 100KVA to 500KVA Total Testing Charges: Rs 1.144L(For Routine test: Rs 30K) Single & 3 Phase Up to100KVA Total Testing Charges :Rs 8.944K (For Routine test: Rs 25K) |
21.2 g)( Separate-source voltage withstand test) |
- |
5000.00 |
|
Above 500KVA to 2500KVA Total Testing Charges: Rs 2.08L(For Routine test : Rs 37K) Above 100KVA to 500KVA Total Testing Charges: Rs 1.144L(For Routine test: Rs 30K) Single & 3 Phase Up to100KVA Total Testing Charges :Rs 8.944K (For Routine test: Rs 25K) |
21.5.3.3(Oil leakage test) |
- |
3500.00 |
|
Above 500KVA to 2500KVA Total Testing Charges: Rs 2.08L(For Routine test : Rs 37K) Above 100KVA to 500KVA Total Testing Charges: Rs 1.144L(For Routine test: Rs 30K) Single & 3 Phase Up to100KVA Total Testing Charges :Rs 8.944K (For Routine test: Rs 25K) |
21.3(a )(Lightning impulse test) |
- |
45000.00 |
|
Above 500KVA to 2500KVA Total Testing Charges: Rs 2.08L(For Routine test : Rs 37K) Above 100KVA to 500KVA Total Testing Charges: Rs 1.144L(For Routine test: Rs 30K) Single & 3 Phase Up to100KVA Total Testing Charges :Rs 8.944K (For Routine test: Rs 25K) |
21.3(b)(Temperature-rise test) |
- |
45000.00 |
|
Above 500KVA to 2500KVA Total Testing Charges: Rs 2.08L(For Routine test : Rs 37K) Above 100KVA to 500KVA Total Testing Charges: Rs 1.144L(For Routine test: Rs 30K) Single & 3 Phase Up to100KVA Total Testing Charges :Rs 8.944K (For Routine test: Rs 25K) |
21.4 a)( Determination of sound levels) |
- |
10000.00 |
|
Above 500KVA to 2500KVA Total Testing Charges: Rs 2.08L(For Routine test : Rs 37K) Above 100KVA to 500KVA Total Testing Charges: Rs 1.144L(For Routine test: Rs 30K) Single & 3 Phase Up to100KVA Total Testing Charges :Rs 8.944K (For Routine test: Rs 25K) |
21.5.1.1(Pressure test-Type test (For Transformers up to 200 kVA
)) |
- |
6000.00 |
|
Above 500KVA to 2500KVA Total Testing Charges: Rs 2.08L(For Routine test : Rs 37K) Above 100KVA to 500KVA Total Testing Charges: Rs 1.144L(For Routine test: Rs 30K) Single & 3 Phase Up to100KVA Total Testing Charges :Rs 8.944K (For Routine test: Rs 25K) |
21.5.1.2(Pressure test-routine test (For Transformers up to 200 kVA
)) |
- |
5000.00 |
|
Above 500KVA to 2500KVA Total Testing Charges: Rs 2.08L(For Routine test : Rs 37K) Above 100KVA to 500KVA Total Testing Charges: Rs 1.144L(For Routine test: Rs 30K) Single & 3 Phase Up to100KVA Total Testing Charges :Rs 8.944K (For Routine test: Rs 25K) |
21.5.2.3( Oil leakage test (routine test)) |
- |
5000.00 |
|
Above 500KVA to 2500KVA Total Testing Charges: Rs 2.08L(For Routine test : Rs 37K) Above 100KVA to 500KVA Total Testing Charges: Rs 1.144L(For Routine test: Rs 30K) Single & 3 Phase Up to100KVA Total Testing Charges :Rs 8.944K (For Routine test: Rs 25K) |
21.5.2.1(Type test : For Transformers Above 200 kVA and Up to Including 2 500 kVA) |
- |
5000.00 |
|
Above 500KVA to 2500KVA Total Testing Charges: Rs 2.08L(For Routine test : Rs 37K) Above 100KVA to 500KVA Total Testing Charges: Rs 1.144L(For Routine test: Rs 30K) Single & 3 Phase Up to100KVA Total Testing Charges :Rs 8.944K (For Routine test: Rs 25K) |
21.5.2.2(routine test :For Transformers Above 200 kVA and Up to Including 2 500 kVA) |
- |
5000.00 |
|
Above 500KVA to 2500KVA Total Testing Charges: Rs 2.08L(For Routine test : Rs 37K) Above 100KVA to 500KVA Total Testing Charges: Rs 1.144L(For Routine test: Rs 30K) Single & 3 Phase Up to100KVA Total Testing Charges :Rs 8.944K (For Routine test: Rs 25K) |
|
Complete
|
|
31 Dec, 2026 |
- Included w.e.f. 10.05.2019
Excluding:
Cl. 22.3 k) Short –circuit test |
3 |
CENTRAL POWER RESEARCH INSTITUTE
| IS 1180 : Part 3 (2021) |
Outdoor/Indoor Type Liquid Immersed Distribution Transformers Up to and Including 2 500 kVA, 33 kV — Specification Part 3 Natural/Synthetic Organic Ester Liquid Immersed |
- |
-
|
1151180 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
21.2 a(Measurement of winding resistance
[IS 2026 (Part 1)].) |
- |
23600 |
|
Estimated tests charges do not include GST. Final charges will include GST at the prevailing rates.
Without tap -11800
With tap- 23600 |
6.1 Table 1(Standard Ratings) |
- |
0 |
|
Estimated tests charges do not include GST. Final charges will include GST at the prevailing rates. |
6.2, 7.2, 8.2(Rated Frequency) |
- |
0 |
|
Estimated tests charges do not include GST. Final charges will include GST at the prevailing rates. |
6.3, 7.3(Nominal System Voltage) |
- |
0 |
|
Estimated tests charges do not include GST. Final charges will include GST at the prevailing rates. |
6.4(Table 2 Minimum Basic Insulation Level) |
- |
0 |
|
Estimated tests charges do not include GST. Final charges will include GST at the prevailing rates. |
6.5, 7.5(No-Load Voltage Ratios) |
- |
0 |
|
Estimated tests charges do not include GST. Final charges will include GST at the prevailing rates. |
6.6, 7.6(Winding Connections and Phase Displacement) |
- |
0 |
|
Estimated tests charges do not include GST. Final charges will include GST at the prevailing rates. |
6.7(Tapping Range and Tapping Methods) |
- |
0 |
|
Estimated tests charges do not include GST. Final charges will include GST at the prevailing rates. |
6.8(Table 3 Losses and Impedance Values) |
- |
0 |
|
Estimated tests charges do not include GST. Final charges will include GST at the prevailing rates. |
6.9(Permissible Flux Density and Over Fluxing) |
- |
0 |
|
Estimated tests charges do not include GST. Final charges will include GST at the prevailing rates. |
6.10(Limits of Temperature-rise) |
- |
0 |
|
Estimated tests charges do not include GST. Final charges will include GST at the prevailing rates. |
7.1(Table 4 Standard Ratings) |
- |
0 |
|
Estimated tests charges do not include GST. Final charges will include GST at the prevailing rates. |
7.4(Table 5 Minimum Basic Insulation Level) |
- |
0 |
|
Estimated tests charges do not include GST. Final charges will include GST at the prevailing rates. |
7.7(Tapping Ranges and Tapping Methods) |
- |
0 |
|
Estimated tests charges do not include GST. Final charges will include GST at the prevailing rates. |
7.8(Losses and Impedance Values) |
- |
0 |
|
Estimated tests charges do not include GST. Final charges will include GST at the prevailing rates. |
7.9(Permissible Flux Density and Overfluxing) |
- |
0 |
|
Estimated tests charges do not include GST. Final charges will include GST at the prevailing rates. |
7.10(Limits of Temperature Rise) |
- |
0 |
|
Estimated tests charges do not include GST. Final charges will include GST at the prevailing rates. |
8.1 Table 7(Standard Ratings) |
- |
0 |
|
Estimated tests charges do not include GST. Final charges will include GST at the prevailing rates. |
8.3(Nominal System Voltage) |
- |
0 |
|
Estimated tests charges do not include GST. Final charges will include GST at the prevailing rates. |
8.5(No Load Voltage Ratio) |
- |
0 |
|
Estimated tests charges do not include GST. Final charges will include GST at the prevailing rates. |
8.6(Number of Phases and Polarity) |
- |
0 |
|
Estimated tests charges do not include GST. Final charges will include GST at the prevailing rates. |
8.4(Table 8 Minimum Basic Insulation Level) |
- |
0 |
|
Estimated tests charges do not include GST. Final charges will include GST at the prevailing rates. |
8.8(Losses and Impedance Values) |
- |
0 |
|
Estimated tests charges do not include GST. Final charges will include GST at the prevailing rates. |
8.9(Permissible Flux Density and Overfluxing) |
- |
0 |
|
Estimated tests charges do not include GST. Final charges will include GST at the prevailing rates. |
8.10(Limits of Temperature Rise) |
- |
0 |
|
Estimated tests charges do not include GST. Final charges will include GST at the prevailing rates. |
9(Standard Materials) |
- |
0 |
|
Estimated tests charges do not include GST. Final charges will include GST at the prevailing rates. |
10(Terminal Arrangement) |
- |
0 |
|
Estimated tests charges do not include GST. Final charges will include GST at the prevailing rates. |
11(Minimum clearances in air) |
- |
0 |
|
Estimated tests charges do not include GST. Final charges will include GST at the prevailing rates. |
12(Connectors (Applicable for bare bushing terminations only)) |
- |
0 |
|
Estimated tests charges do not include GST. Final charges will include GST at the prevailing rates. |
13(Marking) |
- |
0 |
|
Estimated tests charges do not include GST. Final charges will include GST at the prevailing rates. |
14(Mounting Arrangement) |
- |
0 |
|
Estimated tests charges do not include GST. Final charges will include GST at the prevailing rates. |
15(Transformer Tank) |
- |
0 |
|
Estimated tests charges do not include GST. Final charges will include GST at the prevailing rates. |
16(Conservator for non-sealed typetransformers) |
- |
0 |
|
Estimated tests charges do not include GST. Final charges will include GST at the prevailing rates. |
17(Ability of Transformers to withstand external short circuit) |
- |
0 |
|
Estimated tests charges do not include GST. Final charges will include GST at the prevailing rates. |
18(Efficiency and regulation) |
- |
0 |
|
Estimated tests charges do not include GST. Final charges will include GST at the prevailing rates. |
19(Tolerances) |
- |
0 |
|
Estimated tests charges do not include GST. Final charges will include GST at the prevailing rates. |
20(Fittings) |
- |
0 |
|
Estimated tests charges do not include GST. Final charges will include GST at the prevailing rates. |
21.2 b(Measurement of voltage ratio and check of phase
displacement [IS 2026 (Part 1)].) |
- |
41000 |
|
Estimated tests charges do not include GST. Final charges will include GST at the prevailing rates.
Without tap -5900
4 tap- 23500
5 tap-29400
7 Tap-41000 |
21.2 c(Measurement of short-circuit impedance
(principal tapping, when applicable) and load
loss at 50 percent and 100 percent load
[IS 2026 (Part 1)].) |
- |
6900 |
|
Estimated tests charges do not include GST. Final charges will include GST at the prevailing rates.
Without tap -4900
With tap-6900 |
21.2 d(Measurement of no-load loss and current
[IS 2026 (Part 1)].) |
- |
4000 |
|
Estimated tests charges do not include GST. Final charges will include GST at the prevailing rates. |
21.2 e(Measurement of insulation resistance
[IS 2026 (Part 1)].) |
- |
5900 |
|
Estimated tests charges do not include GST. Final charges will include GST at the prevailing rates. |
21.2 f(Induced over-voltage withstand test
[IS 2026 (Part 3)].) |
- |
7400 |
|
Estimated tests charges do not include GST. Final charges will include GST at the prevailing rates. |
21.2 g(Separate-source voltage withstand test
[IS 2026 (Part 3)]) |
- |
3910 |
|
Estimated tests charges do not include GST. Final charges will include GST at the prevailing rates. |
21.3 a(Lightning impulse test [IS 2026 (Part 3)].) |
- |
112040 |
|
Estimated tests charges do not include GST. Final charges will include GST at the prevailing rates.
UPTO 500 KVA-₹64130/-
above 500 KVA TO 2 MVA-₹74090/-
above2 MVA TO 2.5 MVA- ₹112040/- |
21.3 b(Temperature-rise test [IS 2026 (Part 2)].) |
- |
154000 |
|
Estimated tests charges do not include GST. Final charges will include GST at the prevailing rates.
63 KVA-₹23540
63 KVA TO 500KVA-₹35530
500 KVA TO 1000KVA-₹44000
500 KVA TO 1 MVA-₹74090
1 MVA TO 2.5 MVA ₹1,54,000 |
21.3 c(Short-circuit withstand test [IS 2026 (Part 5)]
(up to 200 kVA) and) |
- |
179200 |
|
Estimated tests charges do not include GST. Final charges will include GST at the prevailing rates.
Charges 250 kVA (<=11kV),Without Tap-105400, 5 Tap-151400, 7 Tap-163400
Charges 250 kVA (>11kV),Without Tap-121200, 5 Tap-167200, 7 Tap-179200 |
21.3 d(Pressure test) |
- |
25300 |
|
Estimated tests charges do not include GST. Final charges will include GST at the prevailing rates. |
21.4 a(Determination of sound levels [IS 2026 (Part 10)];) |
- |
61780 |
|
Estimated tests charges do not include GST. Final charges will include GST at the prevailing rates.
5 kVA to 630 kVA- 33350
631 kVA to 1600 kVA- 42320
1600 kVA to 2500 kVA- 61780 |
21.4 b(Short-circuit withstand test [IS 2026 (Part 5)]
(above 200 kVA);) |
- |
588750 |
|
Estimated tests charges do not include GST.
251 kVA to 500 kVA (<=11kV) 5 tap-184200, 7 Tap-196200
251 kVA to 500 kVA (>11kV) 5 tap-226700, 7 Tap-238700
501 kVA to 1600 kVA, 5 tap-465300, 9 Tap- 489300
1600 kVA to 2500 kVA, 5 tap-564800,9 Tap- 588750 |
21.4 c(No load current at 112.5 percent voltage
(see 6.9.2, 7.9.2, 8.9.2);) |
- |
2680 |
|
Estimated tests charges do not include GST. Final charges will include GST at the prevailing rates. |
21.4 d(Paint adhesion test — The test is performed as
per ASTM D3359 (Standard Test Methods for
measuring adhesion by tape test).) |
- |
2520 |
|
Estimated tests charges do not include GST. Final charges will include GST at the prevailing rates. |
21.5(Pressure and Ester Liquid Leakage Test) |
- |
25300 |
|
Estimated tests charges do not include GST. Final charges will include GST at the prevailing rates. |
4(SERVICE CONDITIONS) |
- |
0 |
|
Estimated tests charges do not include GST. Final charges will include GST at the prevailing rates. |
5(General) |
- |
0 |
|
Estimated tests charges do not include GST. Final charges will include GST at the prevailing rates. |
21.4 e(BDV and Moisture content of liquid in the
transformer (IS 16081, IS 16099, IS 16899 or
IS 16659, whichever is applicable).) |
- |
3600 |
|
Estimated tests charges do not include GST. Final charges will include GST at the prevailing rates. |
|
Complete
|
|
30 Jun, 2027 |
- - |
4 |
CENTRAL POWER RESEARCH INSTITUTE
| IS 1180 : Part 1 (2014) |
Outdoor Type Oil Immersed Distribution Transformers Upto and Including 2 500 kVA, 33kV - Specification Part 1 Mineral Oil Immersed (Fourth Revision) |
- |
-
|
1147580 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
17( ABILITY OF TRANSFORMERS TO
WITHSTAND EXTERNAL SHORT CIRCUIT
) |
- |
163400 |
|
Estimated tests charges do not include GST.
Final charges will include GST
Charges up to 250 kVA and 11kV
Without tap -105400
4 tap- 145600
5 tap-151400
7 Tap-163400 |
21.3(c)(Short-circuit withstand test) |
- |
179200 |
|
Estimated tests charges do not include GST. Final charges will include GST
Charges up to 250 kVA (<=11kV),Without Tap-105400, 5 Tap-151400, 7 Tap-163400
Charges up to 250 kVA (>11kV),Without Tap-121200, 5 Tap-167200, 7 Tap-179200 |
21.4 b(Short-circuit withstand test IS 2026 (Part 5) (above 200 kVA)) |
- |
588750 |
|
Estimated tests charges do not include GST.
251 kVA to 500 kVA (<=11kV) 5 tap-184200, 7 Tap-196200
251 kVA to 500 kVA (>11kV) 5 tap-226700, 7 Tap-238700
501 kVA to 1600 kVA, 5 tap-465300, 9 Tap- 489300
1600 kVA to 2500 kVA, 5 tap-564800,9 Tap- 588750 |
21.2 a)(Measurement of winding resistance ) |
- |
23600 |
|
Estimated tests charges do not include GST. Final charges will include GST at the prevailing rates.
Without tap -11800
With tap- 23600 |
21.2 b)( Measurement of voltage ratio and check of
phase displacemen) |
- |
41000 |
|
Estimated tests charges do not include GST. Final charges will include GST
Without tap -5900
4 tap- 23500
5 tap-29400
7 Tap-41000 |
21.2 c)( Measurement of short-circuit impedance
(principal tapping, when applicable) and load
loss at 50 percent and 100 percent load) |
- |
6900 |
|
Estimated tests charges do not include GST. Final charges will include GST at the prevailing rates.
Without tap -4900
With tap-6900 |
21.2 d)(Measurement of no-load loss and current) |
- |
4000 |
|
Estimated tests charges do not include GST. Final charges will include GST at the prevailing rates. |
21.2 e)(Measurement of insulation resistance) |
- |
5900 |
|
Estimated tests charges do not include GST. Final charges will include GST at the prevailing rates. |
21.2 f)(Induced over-voltage withstand test) |
- |
7400 |
|
Estimated tests charges do not include GST. Final charges will include GST at the prevailing rates. |
21.5.3.3(Oil leakage test) |
- |
6400 |
|
Estimated tests charges do not include GST. Final charges will include GST at the prevailing rates. |
21.5.1.1(Pressure test-Type test (For Transformers up to 200 kVA
)) |
- |
25300 |
|
Estimated tests charges do not include GST. Final charges will include GST at the prevailing rates. |
21.5.1.2(Pressure test-routine test (For Transformers up to 200 kVA
)) |
- |
25300 |
|
Estimated tests charges do not include GST. Final charges will include GST at the prevailing rates. |
21.5.2.1(Type test : For Transformers Above 200 kVA and Up to Including 2 500 kVA) |
- |
25300 |
|
Estimated tests charges do not include GST. Final charges will include GST at the prevailing rates. |
21.5.2.2(routine test :For Transformers Above 200 kVA and Up to Including 2 500 kVA) |
- |
25300 |
|
Estimated tests charges do not include GST. Final charges will include GST at the prevailing rates. |
21.5.2.3( Oil leakage test (routine test)) |
- |
6400 |
|
Estimated tests charges do not include GST. Final charges will include GST at the prevailing rates. |
21.5.3.1(For Single Phase Distribution Transformers Up to Including 25 kVA : pressure test (type test)) |
- |
19000 |
|
Estimated tests charges do not include GST. Final charges will include GST at the prevailing rates. |
21.5.3.2(For Single Phase Distribution Transformers Up to Including 25 kVA : pressure test (routine test)) |
- |
19000 |
|
Estimated tests charges do not include GST. Final charges will include GST at the prevailing rates. |
21.5.3.3(Oil leakage test (routine test)) |
- |
6400 |
|
Estimated tests charges do not include GST. Final charges will include GST at the prevailing rates. |
21.4 c(No load current at 112.5 percent voltage.) |
- |
2680 |
|
Estimated tests charges do not include GST. Final charges will include GST at the prevailing rates. |
21.4 d(Paint adhesion tests) |
- |
2520 |
|
Estimated tests charges do not include GST. Final charges will include GST at the prevailing rates. |
21.4 a)( Determination of sound levels) |
- |
61780 |
|
Estimated tests charges do not include GST. Final charges will include GST at the prevailing rates.
5 kVA to 630 kVA- 33350
631 kVA to 1600 kVA- 42320
1600 kVA to 2500 kVA- 61780 |
21.2 g)( Separate-source voltage withstand test) |
- |
3910 |
|
Estimated tests charges do not include GST. Final charges will include GST at the prevailing rates. |
21.3(a )(Lightning impulse test) |
- |
112040 |
|
Estimated tests charges do not include GST. Final charges will include GST at the prevailing rates.
UPTO 500 KVA-₹64130/-
above 500 KVA TO 2 MVA-₹74090/-
above2 MVA TO 2.5 MVA- ₹112040/- |
21.3(b)(Temperature-rise test) |
- |
154000 |
|
Estimated tests charges do not include GST. Final charges will include GST a
63 KVA-₹23540/-
63 KVA TO 500KVA-₹35530/-
500 KVA TO 1000KVA-₹44000/-
500 KVA TO 1 MVA-₹74090/-
1 MVA TO 2.5 MVA ₹1,54,000/ |
|
Complete
|
|
30 Jun, 2027 |
- - |
5 |
NATIONAL TEST HOUSE(SOUTHERN REGION)
| IS 1180 : Part 1 (2014) |
Outdoor Type Oil Immersed Distribution Transformers Upto and Including 2 500 kVA, 33kV - Specification Part 1 Mineral Oil Immersed (Fourth Revision) |
- |
-
|
105000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
13.1(Marking (Rating Plates)) |
- |
0 |
|
- |
13.2(Terminal Marking Plate) |
- |
0 |
|
- |
13.3(Marking ) |
- |
0 |
|
- |
13.4(Marking) |
- |
0 |
|
- |
13.4.1(Marking) |
- |
0 |
|
- |
14.1(MOUNTING ARRANGEMENT) |
- |
0 |
|
- |
14.2(MOUNTING ARRANGEMENT) |
- |
0 |
|
- |
14.3(MOUNTING ARRANGEMENT) |
- |
0 |
|
- |
14.4(MOUNTING ARRANGEMENT) |
- |
0 |
|
- |
15.1.1(TRANSFORMER TANK : Construction) |
- |
0 |
|
- |
15.1.2(TRANSFORMER TANK : Construction) |
- |
0 |
|
- |
15.1.3(TRANSFORMER TANK : Construction) |
- |
0 |
|
- |
15.1.4(TRANSFORMER TANK : Construction) |
- |
0 |
|
- |
15.1.5(TRANSFORMER TANK : Construction) |
- |
0 |
|
- |
21.2 a)(Measurement of winding resistance ) |
- |
1000 |
|
- |
21.2 b)( Measurement of voltage ratio and check of
phase displacemen) |
- |
1000 |
|
- |
21.2 c)( Measurement of short-circuit impedance
(principal tapping, when applicable) and load
loss at 50 percent and 100 percent load) |
- |
5000 |
|
- |
21.2 d)(Measurement of no-load loss and current) |
- |
5000 |
|
- |
21.2 e)(Measurement of insulation resistance) |
- |
500 |
|
- |
21.2 f)(Induced over-voltage withstand test) |
- |
1000 |
|
- |
21.2 g)( Separate-source voltage withstand test) |
- |
1000 |
|
- |
21.5.3.3(Oil leakage test) |
- |
2000 |
|
- |
21.3(a )(Lightning impulse test) |
- |
35000 |
|
- |
21.3(b)(Temperature-rise test) |
- |
25000 |
|
- |
21.4 a)( Determination of sound levels) |
- |
2000 |
|
- |
21.5.1.1(Pressure test-Type test (For Transformers up to 200 kVA
)) |
- |
6000 |
|
- |
21.5.1.2(Pressure test-routine test (For Transformers up to 200 kVA
)) |
- |
3000 |
|
- |
21.5.2.1(Type test : For Transformers Above 200 kVA and Up to Including 2 500 kVA) |
- |
0 |
|
- |
21.5.2.2(routine test :For Transformers Above 200 kVA and Up to Including 2 500 kVA) |
- |
0 |
|
- |
21.5.2.3( Oil leakage test (routine test)) |
- |
2000 |
|
- |
21.5.3.1(For Single Phase Distribution Transformers Up to Including 25 kVA : pressure test (type test)) |
- |
0 |
|
- |
21.5.3.2(For Single Phase Distribution Transformers Up to Including 25 kVA : pressure test (routine test)) |
- |
0 |
|
- |
21.5.3.3(Oil leakage test (routine test)) |
- |
2000 |
|
- |
21.4 c(No load current at 112.5 percent voltage.) |
- |
2500 |
|
- |
21.4 d(Paint adhesion tests) |
- |
1000 |
|
- |
21.4 e(BDV and moisture content of oil in the transformer) |
- |
4000 |
|
- |
6.9, 7.9, 8.9(Permissible Flux Density and Over Fluxing) |
- |
6000 |
|
- |
11(Minimum clearance in Air) |
- |
0 |
|
- |
16(Conservator for Non-sealed type Transformers) |
- |
0 |
|
- |
20(Fittings) |
- |
0 |
|
- |
6.8 (50%)(Total losses at 50 % load (Watts)) |
- |
0 |
|
- |
7.8 (50%)(Total losses at 50 % load (Watts)) |
- |
0 |
|
- |
8.8 (50%)(Total losses at 50 % load (Watts)) |
- |
0 |
|
- |
6.8 (100%)(Total losses at 100 % load (Watts)) |
- |
0 |
|
- |
7.8 (100%)(Total losses at 100 % load (Watts)) |
- |
0 |
|
- |
8.8 (100%)(Total losses at 100 % load (Watts)) |
- |
0 |
|
- |
21.5.1.3(Oil leakage test upto 200 KVA) |
- |
0 |
|
- |
9.1 f)(Mineral oil) |
- |
0 |
|
- |
10(Terminal Arrangement) |
- |
0 |
|
- |
15.2(Pressure and Vacuum Requirements) |
- |
0 |
|
- |
15.4(Gasket) |
- |
0 |
|
- |
19(Tolerances) |
- |
0 |
|
- |
20(Fittings) |
- |
0 |
|
- |
21(General ) |
- |
0 |
|
- |
22(Information required with enquiry and order ) |
- |
0 |
|
- |
6.1(Rating) |
- |
0 |
|
- |
6.2(Rated frequency) |
- |
0 |
|
- |
6.3(Nominal system voltage) |
- |
0 |
|
- |
6.4(Basic Insulation level ) |
- |
0 |
|
- |
6.5(No-Load Voltage Ratios) |
- |
0 |
|
- |
6.6(Winding connections and phase displacement) |
- |
0 |
|
- |
6.7(Tapping Range and Tapping Method) |
- |
0 |
|
- |
6.8(Losses and impedance values) |
- |
0 |
|
- |
6.9(Permissible Flux Density and Over Fluxing ) |
- |
0 |
|
- |
7(Technical Parameters of three phase distribution trasnformers
higher than 200kva) |
- |
0 |
|
- |
8(Technical Parameters of single phase distribution transformers
UP to and including 25 KVA ) |
- |
0 |
|
- |
9(Standard Materials) |
- |
0 |
|
- |
10(Terminal arrangment ) |
- |
0 |
|
- |
9.1a)(CRGO Electrical Steel) |
- |
0 |
|
- |
9.1 b)(Amorphous core material) |
- |
0 |
|
- |
9.1 c)(Copper/Aluminium conductor) |
- |
0 |
|
- |
9.1 d)(Kraft paper) |
- |
0 |
|
- |
9.1 e)(Press Board) |
- |
0 |
|
- |
18(Efficiency and regulation) |
- |
0 |
|
- |
4(Service Conditions) |
- |
0 |
|
- |
5(General ) |
- |
0 |
|
- |
11(Minimum Clearnaces air ) |
- |
0 |
|
- |
12(Connectors ) |
- |
0 |
|
- |
13(Marking ) |
- |
0 |
|
- |
14(Mounting arrangement) |
- |
0 |
|
- |
15(Trasnformer Tank ) |
- |
0 |
|
- |
16(Conservator for Non-Sealed type Transformers) |
- |
0 |
|
- |
18(Efficiency and Regulation) |
- |
0 |
|
- |
19(Tolerances) |
- |
0 |
|
- |
6.1(Limits of Temperature-rise) |
- |
0 |
|
- |
15.5(Total Dry Film Paint Thickness) |
- |
0 |
|
- |
13.1(Marking (Rating Plates)) |
- |
0 |
|
- |
13.2(Terminal Marking Plate) |
- |
0 |
|
- |
13.3(Marking ) |
- |
0 |
|
- |
13.4(Marking) |
- |
0 |
|
- |
13.4.1(Marking) |
- |
0 |
|
- |
14.1(MOUNTING ARRANGEMENT) |
- |
0 |
|
- |
14.2(MOUNTING ARRANGEMENT) |
- |
0 |
|
- |
14.3(MOUNTING ARRANGEMENT) |
- |
0 |
|
- |
14.4(MOUNTING ARRANGEMENT) |
- |
0 |
|
- |
15.1.1(TRANSFORMER TANK : Construction) |
- |
0 |
|
- |
15.1.2(TRANSFORMER TANK : Construction) |
- |
0 |
|
- |
15.1.3(TRANSFORMER TANK : Construction) |
- |
0 |
|
- |
15.1.4(TRANSFORMER TANK : Construction) |
- |
0 |
|
- |
15.1.5(TRANSFORMER TANK : Construction) |
- |
0 |
|
- |
21.2 a)(Measurement of winding resistance ) |
- |
1000 |
|
- |
21.2 b)( Measurement of voltage ratio and check of
phase displacemen) |
- |
1000 |
|
- |
21.2 c)( Measurement of short-circuit impedance
(principal tapping, when applicable) and load
loss at 50 percent and 100 percent load) |
- |
5000 |
|
- |
21.2 d)(Measurement of no-load loss and current) |
- |
5000 |
|
- |
21.2 e)(Measurement of insulation resistance) |
- |
500 |
|
- |
21.2 f)(Induced over-voltage withstand test) |
- |
1000 |
|
- |
21.2 g)( Separate-source voltage withstand test) |
- |
1000 |
|
- |
21.3(a )(Lightning impulse test) |
- |
35000 |
|
- |
21.3(b)(Temperature-rise test) |
- |
25000 |
|
- |
21.4 a)( Determination of sound levels) |
- |
2000 |
|
- |
21.5.1.1(Pressure test-Type test (For Transformers up to 200 kVA
)) |
- |
6000 |
|
- |
21.5.1.2(Pressure test-routine test (For Transformers up to 200 kVA
)) |
- |
3000 |
|
- |
21.5.2.1(Type test : For Transformers Above 200 kVA and Up to Including 2 500 kVA) |
- |
0 |
|
- |
21.5.2.2(routine test :For Transformers Above 200 kVA and Up to Including 2 500 kVA) |
- |
0 |
|
- |
21.5.2.3( Oil leakage test (routine test)) |
- |
2000 |
|
- |
21.5.3.1(For Single Phase Distribution Transformers Up to Including 25 kVA : pressure test (type test)) |
- |
0 |
|
- |
21.5.3.2(For Single Phase Distribution Transformers Up to Including 25 kVA : pressure test (routine test)) |
- |
0 |
|
- |
21.5.3.3(Oil leakage test (routine test)) |
- |
2000 |
|
- |
21.4 c(No load current at 112.5 percent voltage.) |
- |
2500 |
|
- |
21.4 d(Paint adhesion tests) |
- |
1000 |
|
- |
21.4 e(BDV and moisture content of oil in the transformer) |
- |
4000 |
|
- |
6.9, 7.9, 8.9(Permissible Flux Density and Over Fluxing) |
- |
6000 |
|
- |
11(Minimum clearance in Air) |
- |
0 |
|
- |
16(Conservator for Non-sealed type Transformers) |
- |
0 |
|
- |
20(Fittings) |
- |
0 |
|
- |
6.8 (50%)(Total losses at 50 % load (Watts)) |
- |
0 |
|
- |
7.8 (50%)(Total losses at 50 % load (Watts)) |
- |
0 |
|
- |
8.8 (50%)(Total losses at 50 % load (Watts)) |
- |
0 |
|
- |
6.8 (100%)(Total losses at 100 % load (Watts)) |
- |
0 |
|
- |
7.8 (100%)(Total losses at 100 % load (Watts)) |
- |
0 |
|
- |
8.8 (100%)(Total losses at 100 % load (Watts)) |
- |
0 |
|
- |
21.5.1.3(Oil leakage test upto 200 KVA) |
- |
2000 |
|
- |
9.1 f)(Mineral oil) |
- |
0 |
|
- |
15.2(Pressure and Vacuum Requirements) |
- |
0 |
|
- |
6.1(Rating) |
- |
0 |
|
- |
6.2(Rated frequency) |
- |
0 |
|
- |
6.3(Nominal system voltage) |
- |
0 |
|
- |
6.4(Basic Insulation level ) |
- |
0 |
|
- |
6.5(No-Load Voltage Ratios) |
- |
0 |
|
- |
6.6(Winding connections and phase displacement) |
- |
0 |
|
- |
6.7(Tapping Range and Tapping Method) |
- |
0 |
|
- |
6.9(Permissible Flux Density and Over Fluxing ) |
- |
0 |
|
- |
7(Technical Parameters of three phase distribution trasnformers
higher than 200kva) |
- |
0 |
|
- |
8(Technical Parameters of single phase distribution transformers
UP to and including 25 KVA ) |
- |
0 |
|
- |
10(Terminal arrangment ) |
- |
0 |
|
- |
18(Efficiency and regulation) |
- |
0 |
|
- |
12(Connectors ) |
- |
0 |
|
- |
21.5.3.3(Oil leakage test) |
- |
0 |
|
- |
9.1a)(CRGO Electrical Steel) |
- |
0 |
|
- |
9.1 b)(Amorphous core material) |
- |
0 |
|
- |
9.1 c)(Copper/Aluminium conductor) |
- |
0 |
|
- |
9.1 d)(Kraft paper) |
- |
0 |
|
- |
9.1 e)(Press Board) |
- |
0 |
|
- |
15.5(Total Dry Film Paint Thickness) |
- |
0 |
|
- |
10(Terminal Arrangement) |
- |
0 |
|
- |
15.4(Gasket) |
- |
0 |
|
- |
19(Tolerances) |
- |
0 |
|
- |
4(Service Conditions) |
- |
0 |
|
- |
5(General ) |
- |
0 |
|
- |
9(Standard Materials) |
- |
0 |
|
- |
11(Minimum Clearnaces air ) |
- |
0 |
|
- |
13(Marking ) |
- |
0 |
|
- |
14(Mounting arrangement) |
- |
0 |
|
- |
15(Trasnformer Tank ) |
- |
0 |
|
- |
16(Conservator for Non-Sealed type Transformers) |
- |
0 |
|
- |
18(Efficiency and Regulation) |
- |
0 |
|
- |
19(Tolerances) |
- |
0 |
|
- |
20(Fittings) |
- |
0 |
|
- |
21(General ) |
- |
0 |
|
- |
22(Information required with enquiry and order ) |
- |
0 |
|
- |
6.8(Losses and impedance values) |
- |
0 |
|
- |
6.1(Limits of Temperature-rise) |
- |
0 |
|
- |
13.1(Marking (Rating Plates)) |
- |
0 |
|
- |
13.2(Terminal Marking Plate) |
- |
0 |
|
- |
13.3(Marking ) |
- |
0 |
|
- |
13.4(Marking) |
- |
0 |
|
- |
13.4.1(Marking) |
- |
0 |
|
- |
14.1(MOUNTING ARRANGEMENT) |
- |
0 |
|
- |
14.2(MOUNTING ARRANGEMENT) |
- |
0 |
|
- |
14.3(MOUNTING ARRANGEMENT) |
- |
0 |
|
- |
14.4(MOUNTING ARRANGEMENT) |
- |
0 |
|
- |
15.1.1(TRANSFORMER TANK : Construction) |
- |
0 |
|
- |
15.1.2(TRANSFORMER TANK : Construction) |
- |
0 |
|
- |
15.1.3(TRANSFORMER TANK : Construction) |
- |
0 |
|
- |
15.1.4(TRANSFORMER TANK : Construction) |
- |
0 |
|
- |
15.1.5(TRANSFORMER TANK : Construction) |
- |
0 |
|
- |
21.2 a)(Measurement of winding resistance ) |
- |
0 |
|
- |
21.2 b)( Measurement of voltage ratio and check of
phase displacemen) |
- |
0 |
|
- |
21.2 c)( Measurement of short-circuit impedance
(principal tapping, when applicable) and load
loss at 50 percent and 100 percent load) |
- |
0 |
|
- |
21.2 d)(Measurement of no-load loss and current) |
- |
0 |
|
- |
21.2 e)(Measurement of insulation resistance) |
- |
0 |
|
- |
21.2 f)(Induced over-voltage withstand test) |
- |
0 |
|
- |
21.2 g)( Separate-source voltage withstand test) |
- |
0 |
|
- |
21.3(a )(Lightning impulse test) |
- |
0 |
|
- |
21.3(b)(Temperature-rise test) |
- |
0 |
|
- |
21.4 a)( Determination of sound levels) |
- |
0 |
|
- |
21.5.1.1(Pressure test-Type test (For Transformers up to 200 kVA
)) |
- |
0 |
|
- |
21.5.1.2(Pressure test-routine test (For Transformers up to 200 kVA
)) |
- |
0 |
|
- |
21.5.2.1(Type test : For Transformers Above 200 kVA and Up to Including 2 500 kVA) |
- |
0 |
|
- |
21.5.2.2(routine test :For Transformers Above 200 kVA and Up to Including 2 500 kVA) |
- |
0 |
|
- |
21.5.2.3( Oil leakage test (routine test)) |
- |
0 |
|
- |
21.5.3.1(For Single Phase Distribution Transformers Up to Including 25 kVA : pressure test (type test)) |
- |
0 |
|
- |
21.5.3.2(For Single Phase Distribution Transformers Up to Including 25 kVA : pressure test (routine test)) |
- |
0 |
|
- |
21.5.3.3(Oil leakage test (routine test)) |
- |
0 |
|
- |
21.4 c(No load current at 112.5 percent voltage.) |
- |
0 |
|
- |
21.4 d(Paint adhesion tests) |
- |
0 |
|
- |
21.4 e(BDV and moisture content of oil in the transformer) |
- |
0 |
|
- |
6.9, 7.9, 8.9(Permissible Flux Density and Over Fluxing) |
- |
0 |
|
- |
11(Minimum clearance in Air) |
- |
0 |
|
- |
16(Conservator for Non-sealed type Transformers) |
- |
0 |
|
- |
20(Fittings) |
- |
0 |
|
- |
6.8 (50%)(Total losses at 50 % load (Watts)) |
- |
0 |
|
- |
7.8 (50%)(Total losses at 50 % load (Watts)) |
- |
0 |
|
- |
8.8 (50%)(Total losses at 50 % load (Watts)) |
- |
0 |
|
- |
6.8 (100%)(Total losses at 100 % load (Watts)) |
- |
0 |
|
- |
7.8 (100%)(Total losses at 100 % load (Watts)) |
- |
0 |
|
- |
8.8 (100%)(Total losses at 100 % load (Watts)) |
- |
0 |
|
- |
21.5.1.3(Oil leakage test upto 200 KVA) |
- |
0 |
|
- |
9.1 f)(Mineral oil) |
- |
0 |
|
- |
15.2(Pressure and Vacuum Requirements) |
- |
0 |
|
- |
6.1(Rating) |
- |
0 |
|
- |
6.2(Rated frequency) |
- |
0 |
|
- |
6.3(Nominal system voltage) |
- |
0 |
|
- |
6.4(Basic Insulation level ) |
- |
0 |
|
- |
6.5(No-Load Voltage Ratios) |
- |
0 |
|
- |
6.6(Winding connections and phase displacement) |
- |
0 |
|
- |
6.7(Tapping Range and Tapping Method) |
- |
0 |
|
- |
6.9(Permissible Flux Density and Over Fluxing ) |
- |
0 |
|
- |
7(Technical Parameters of three phase distribution trasnformers
higher than 200kva) |
- |
0 |
|
- |
8(Technical Parameters of single phase distribution transformers
UP to and including 25 KVA ) |
- |
0 |
|
- |
10(Terminal arrangment ) |
- |
0 |
|
- |
18(Efficiency and regulation) |
- |
0 |
|
- |
12(Connectors ) |
- |
0 |
|
- |
21.5.3.3(Oil leakage test) |
- |
0 |
|
- |
9.1a)(CRGO Electrical Steel) |
- |
0 |
|
- |
9.1 b)(Amorphous core material) |
- |
0 |
|
- |
9.1 c)(Copper/Aluminium conductor) |
- |
0 |
|
- |
9.1 d)(Kraft paper) |
- |
0 |
|
- |
9.1 e)(Press Board) |
- |
0 |
|
- |
15.5(Total Dry Film Paint Thickness) |
- |
0 |
|
- |
10(Terminal Arrangement) |
- |
0 |
|
- |
15.4(Gasket) |
- |
0 |
|
- |
19(Tolerances) |
- |
0 |
|
- |
4(Service Conditions) |
- |
0 |
|
- |
5(General ) |
- |
0 |
|
- |
9(Standard Materials) |
- |
0 |
|
- |
11(Minimum Clearnaces air ) |
- |
0 |
|
- |
13(Marking ) |
- |
0 |
|
- |
14(Mounting arrangement) |
- |
0 |
|
- |
15(Trasnformer Tank ) |
- |
0 |
|
- |
16(Conservator for Non-Sealed type Transformers) |
- |
0 |
|
- |
18(Efficiency and Regulation) |
- |
0 |
|
- |
19(Tolerances) |
- |
0 |
|
- |
20(Fittings) |
- |
0 |
|
- |
21(General ) |
- |
0 |
|
- |
22(Information required with enquiry and order ) |
- |
0 |
|
- |
6.8(Losses and impedance values) |
- |
0 |
|
- |
6.1(Limits of Temperature-rise) |
- |
0 |
|
- |
|
Complete
|
|
28 Nov, 2025 |
- Included w.e.f.06.12.2024
Exclusion
CL 21.4 b (Short-circuit withstand test IS 2026 (Part 5) (above 200 kVA))
CL 21.3(c) (Short-circuit withstand test)
CL 17 (Ability of transformers to withstand external Short circuit ) |
6 |
KC INDIA TEST LABORATORIES LLP
| IS 1180 : Part 1 (2014) |
Outdoor Type Oil Immersed Distribution Transformers Upto and Including 2 500 kVA, 33kV - Specification Part 1 Mineral Oil Immersed (Fourth Revision) |
Upto and including 2500 KVA |
-
|
125000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
13.1(Marking (Rating Plates)) |
- |
100 |
|
NIL |
13.2(Terminal Marking Plate) |
- |
100 |
|
NIL |
13.3(Marking ) |
- |
100 |
|
NIL |
13.4(Marking) |
- |
100 |
|
NIL |
13.4.1(Marking) |
- |
100 |
|
NIL |
14.1(MOUNTING ARRANGEMENT) |
- |
100 |
|
NIL |
14.2(MOUNTING ARRANGEMENT) |
- |
100 |
|
NIL |
14.3(MOUNTING ARRANGEMENT) |
- |
100 |
|
NIL |
14.4(MOUNTING ARRANGEMENT) |
- |
100 |
|
NIL |
15.1.1(TRANSFORMER TANK : Construction) |
- |
100 |
|
NIL |
15.1.2(TRANSFORMER TANK : Construction) |
- |
100 |
|
NIL |
15.1.3(TRANSFORMER TANK : Construction) |
- |
100 |
|
NIL |
15.1.4(TRANSFORMER TANK : Construction) |
- |
100 |
|
NIL |
15.1.5(TRANSFORMER TANK : Construction) |
- |
100 |
|
NIL |
21.2 a)(Measurement of winding resistance ) |
- |
100 |
|
NIL |
21.2 b)( Measurement of voltage ratio and check of
phase displacemen) |
- |
4000 |
|
NIL |
21.2 c)( Measurement of short-circuit impedance
(principal tapping, when applicable) and load
loss at 50 percent and 100 percent load) |
- |
4000 |
|
NIL |
21.2 d)(Measurement of no-load loss and current) |
- |
4000 |
|
NIL |
21.2 e)(Measurement of insulation resistance) |
- |
2000 |
|
NIL |
21.2 f)(Induced over-voltage withstand test) |
- |
2000 |
|
NIL |
21.2 g)( Separate-source voltage withstand test) |
- |
2000 |
|
NIL |
21.5.3.3(Oil leakage test) |
- |
1000 |
|
NIL |
21.3(a )(Lightning impulse test) |
- |
5500 |
|
NIL |
21.3(b)(Temperature-rise test) |
- |
8000 |
|
NIL |
21.4 a)( Determination of sound levels) |
- |
2500 |
|
NIL |
21.5.1.1(Pressure test-Type test (For Transformers up to 200 kVA
)) |
- |
2500 |
|
NIL |
21.5.1.2(Pressure test-routine test (For Transformers up to 200 kVA
)) |
- |
2500 |
|
NIL |
21.5.2.1(Type test : For Transformers Above 200 kVA and Up to Including 2 500 kVA) |
- |
2500 |
|
NIL |
21.5.2.2(routine test :For Transformers Above 200 kVA and Up to Including 2 500 kVA) |
- |
2500 |
|
NIL |
21.5.2.3( Oil leakage test (routine test)) |
- |
2000 |
|
NIL |
21.5.3.1(For Single Phase Distribution Transformers Up to Including 25 kVA : pressure test (type test)) |
- |
2500 |
|
NIL |
21.5.3.2(For Single Phase Distribution Transformers Up to Including 25 kVA : pressure test (routine test)) |
- |
2500 |
|
NIL |
21.5.3.3(Oil leakage test (routine test)) |
- |
2500 |
|
NIL |
21.4 c(No load current at 112.5 percent voltage.) |
- |
45000 |
|
NIL |
21.4 d(Paint adhesion tests) |
- |
2500 |
|
NIL |
21.4 e(BDV and moisture content of oil in the transformer) |
- |
4000 |
|
NIL |
15.5(Total Dry Film Paint Thickness) |
- |
4000 |
|
NIL |
6.9, 7.9, 8.9(Permissible Flux Density and Over Fluxing) |
- |
2500 |
|
NIL |
11(Minimum clearance in Air) |
- |
1000 |
|
NIL |
16(Conservator for Non-sealed type Transformers) |
- |
1000 |
|
NIL |
20(Fittings) |
- |
1000 |
|
NIL |
6.8 (50%)(Total losses at 50 % load (Watts)) |
- |
2500 |
|
NIL |
7.8 (50%)(Total losses at 50 % load (Watts)) |
- |
2500 |
|
NIL |
8.8 (50%)(Total losses at 50 % load (Watts)) |
- |
2500 |
|
NIL |
6.8 (100%)(Total losses at 100 % load (Watts)) |
- |
2500 |
|
NIL |
7.8 (100%)(Total losses at 100 % load (Watts)) |
- |
2500 |
|
NIL |
8.8 (100%)(Total losses at 100 % load (Watts)) |
- |
2500 |
|
NIL |
21.5.1.3(Oil leakage test upto 200 KVA) |
- |
4000 |
|
NIL |
9.1a)(CRGO Electrical Steel) |
- |
200 |
|
NIL |
9.1 b)(Amorphous core material) |
- |
200 |
|
NIL |
9.1 c)(Copper/Aluminium conductor) |
- |
200 |
|
NIL |
9.1 d)(Kraft paper) |
- |
200 |
|
NIL |
9.1 e)(Press Board) |
- |
200 |
|
NIL |
9.1 f)(Mineral oil) |
- |
200 |
|
NIL |
10(Terminal Arrangement) |
- |
200 |
|
NIL |
15.2(Pressure and Vacuum Requirements) |
- |
200 |
|
NIL |
15.4(Gasket) |
- |
200 |
|
NIL |
19(Tolerances) |
- |
200 |
|
NIL |
18(Efficiency and regulation) |
- |
1000 |
|
NIL |
4(Service Conditions) |
- |
200 |
|
NIL |
5(General ) |
- |
200 |
|
NIL |
6.1(Rating) |
- |
200 |
|
NIL |
6.2(Rated frequency) |
- |
200 |
|
NIL |
6.3(Nominal system voltage) |
- |
200 |
|
NIL |
6.4(Basic Insulation level ) |
- |
200 |
|
NIL |
6.5(No-Load Voltage Ratios) |
- |
1000 |
|
NIL |
6.6(Winding connections and phase displacement) |
- |
2000 |
|
NIL |
6.7(Tapping Range and Tapping Method) |
- |
2000 |
|
NIL |
6.8(Losses and impedance values) |
- |
1000 |
|
NIL |
6.9(Permissible Flux Density and Over Fluxing ) |
- |
1000 |
|
NIL |
6.1(Limits of Temperature-rise) |
- |
2500 |
|
NIL |
7(Technical Parameters of three phase distribution trasnformers
higher than 200kva) |
- |
1000 |
|
NIL |
8(Technical Parameters of single phase distribution transformers
UP to and including 25 KVA ) |
- |
1000 |
|
NIL |
9(Standard Materials) |
- |
1000 |
|
NIL |
10(Terminal arrangment ) |
- |
1000 |
|
NIL |
11(Minimum Clearnaces air ) |
- |
1000 |
|
NIL |
12(Connectors ) |
- |
100 |
|
NIL |
13(Marking ) |
- |
200 |
|
NIL |
14(Mounting arrangement) |
- |
200 |
|
NIL |
15(Trasnformer Tank ) |
- |
200 |
|
NIL |
16(Conservator for Non-Sealed type Transformers) |
- |
200 |
|
NIL |
18(Efficiency and Regulation) |
- |
1000 |
|
NIL |
19(Tolerances) |
- |
200 |
|
NIL |
20(Fittings) |
- |
200 |
|
NIL |
21(General ) |
- |
200 |
|
NIL |
22(Information required with enquiry and order ) |
- |
200 |
|
NIL |
13.1(Marking (Rating Plates)) |
- |
100 |
|
NIL |
13.2(Terminal Marking Plate) |
- |
100 |
|
NIL |
13.3(Marking ) |
- |
100 |
|
NIL |
13.4(Marking) |
- |
100 |
|
NIL |
13.4.1(Marking) |
- |
100 |
|
NIL |
14.1(MOUNTING ARRANGEMENT) |
- |
100 |
|
NIL |
14.2(MOUNTING ARRANGEMENT) |
- |
100 |
|
NIL |
14.3(MOUNTING ARRANGEMENT) |
- |
100 |
|
NIL |
14.4(MOUNTING ARRANGEMENT) |
- |
100 |
|
NIL |
15.1.1(TRANSFORMER TANK : Construction) |
- |
100 |
|
NIL |
15.1.2(TRANSFORMER TANK : Construction) |
- |
100 |
|
NIL |
15.1.3(TRANSFORMER TANK : Construction) |
- |
100 |
|
NIL |
15.1.4(TRANSFORMER TANK : Construction) |
- |
100 |
|
NIL |
15.1.5(TRANSFORMER TANK : Construction) |
- |
100 |
|
NIL |
21.2 a)(Measurement of winding resistance ) |
- |
100 |
|
NIL |
21.2 b)( Measurement of voltage ratio and check of
phase displacemen) |
- |
4000 |
|
NIL |
21.2 c)( Measurement of short-circuit impedance
(principal tapping, when applicable) and load
loss at 50 percent and 100 percent load) |
- |
4000 |
|
NIL |
21.2 d)(Measurement of no-load loss and current) |
- |
4000 |
|
NIL |
21.2 e)(Measurement of insulation resistance) |
- |
2000 |
|
NIL |
21.2 f)(Induced over-voltage withstand test) |
- |
2000 |
|
NIL |
21.2 g)( Separate-source voltage withstand test) |
- |
2000 |
|
NIL |
21.5.3.3(Oil leakage test) |
- |
1000 |
|
NIL |
21.3(a )(Lightning impulse test) |
- |
5500 |
|
NIL |
21.3(b)(Temperature-rise test) |
- |
8000 |
|
NIL |
21.4 a)( Determination of sound levels) |
- |
2500 |
|
NIL |
21.5.1.1(Pressure test-Type test (For Transformers up to 200 kVA
)) |
- |
2500 |
|
NIL |
21.5.1.2(Pressure test-routine test (For Transformers up to 200 kVA
)) |
- |
2500 |
|
NIL |
21.5.2.1(Type test : For Transformers Above 200 kVA and Up to Including 2 500 kVA) |
- |
2500 |
|
NIL |
21.5.2.2(routine test :For Transformers Above 200 kVA and Up to Including 2 500 kVA) |
- |
2500 |
|
NIL |
21.5.2.3( Oil leakage test (routine test)) |
- |
2000 |
|
NIL |
21.5.3.1(For Single Phase Distribution Transformers Up to Including 25 kVA : pressure test (type test)) |
- |
2500 |
|
NIL |
21.5.3.2(For Single Phase Distribution Transformers Up to Including 25 kVA : pressure test (routine test)) |
- |
2500 |
|
NIL |
21.5.3.3(Oil leakage test (routine test)) |
- |
2500 |
|
NIL |
21.4 c(No load current at 112.5 percent voltage.) |
- |
45000 |
|
NIL |
21.4 d(Paint adhesion tests) |
- |
2500 |
|
NIL |
21.4 e(BDV and moisture content of oil in the transformer) |
- |
4000 |
|
NIL |
15.5(Total Dry Film Paint Thickness) |
- |
4000 |
|
NIL |
6.9, 7.9, 8.9(Permissible Flux Density and Over Fluxing) |
- |
2500 |
|
NIL |
11(Minimum clearance in Air) |
- |
1000 |
|
NIL |
16(Conservator for Non-sealed type Transformers) |
- |
1000 |
|
NIL |
20(Fittings) |
- |
1000 |
|
NIL |
6.8 (50%)(Total losses at 50 % load (Watts)) |
- |
2500 |
|
NIL |
7.8 (50%)(Total losses at 50 % load (Watts)) |
- |
2500 |
|
NIL |
8.8 (50%)(Total losses at 50 % load (Watts)) |
- |
2500 |
|
NIL |
6.8 (100%)(Total losses at 100 % load (Watts)) |
- |
2500 |
|
NIL |
7.8 (100%)(Total losses at 100 % load (Watts)) |
- |
2500 |
|
NIL |
8.8 (100%)(Total losses at 100 % load (Watts)) |
- |
2500 |
|
NIL |
21.5.1.3(Oil leakage test upto 200 KVA) |
- |
4000 |
|
NIL |
9.1a)(CRGO Electrical Steel) |
- |
200 |
|
NIL |
9.1 b)(Amorphous core material) |
- |
200 |
|
NIL |
9.1 c)(Copper/Aluminium conductor) |
- |
200 |
|
NIL |
9.1 d)(Kraft paper) |
- |
200 |
|
NIL |
9.1 e)(Press Board) |
- |
200 |
|
NIL |
9.1 f)(Mineral oil) |
- |
200 |
|
NIL |
10(Terminal Arrangement) |
- |
200 |
|
NIL |
15.2(Pressure and Vacuum Requirements) |
- |
200 |
|
NIL |
15.4(Gasket) |
- |
200 |
|
NIL |
19(Tolerances) |
- |
200 |
|
NIL |
18(Efficiency and regulation) |
- |
1000 |
|
NIL |
4(Service Conditions) |
- |
200 |
|
NIL |
5(General ) |
- |
200 |
|
NIL |
6.1(Rating) |
- |
200 |
|
NIL |
6.2(Rated frequency) |
- |
200 |
|
NIL |
6.3(Nominal system voltage) |
- |
200 |
|
NIL |
6.4(Basic Insulation level ) |
- |
200 |
|
NIL |
6.5(No-Load Voltage Ratios) |
- |
200 |
|
NIL |
6.6(Winding connections and phase displacement) |
- |
200 |
|
NIL |
6.7(Tapping Range and Tapping Method) |
- |
2000 |
|
NIL |
6.8(Losses and impedance values) |
- |
2000 |
|
NIL |
6.9(Permissible Flux Density and Over Fluxing ) |
- |
1000 |
|
NIL |
6.1(Limits of Temperature-rise) |
- |
200 |
|
NIL |
7(Technical Parameters of three phase distribution trasnformers
higher than 200kva) |
- |
200 |
|
NIL |
8(Technical Parameters of single phase distribution transformers
UP to and including 25 KVA ) |
- |
200 |
|
NIL |
9(Standard Materials) |
- |
200 |
|
NIL |
10(Terminal arrangment ) |
- |
200 |
|
NIL |
11(Minimum Clearnaces air ) |
- |
1000 |
|
NIL |
12(Connectors ) |
- |
200 |
|
NIL |
13(Marking ) |
- |
200 |
|
NIL |
14(Mounting arrangement) |
- |
200 |
|
NIL |
15(Trasnformer Tank ) |
- |
200 |
|
NIL |
16(Conservator for Non-Sealed type Transformers) |
- |
200 |
|
NIL |
18(Efficiency and Regulation) |
- |
1000 |
|
NIL |
19(Tolerances) |
- |
200 |
|
NIL |
20(Fittings) |
- |
200 |
|
NIL |
21(General ) |
- |
200 |
|
NIL |
22(Information required with enquiry and order ) |
- |
200 |
|
NIL |
13.1(Marking (Rating Plates)) |
- |
100 |
|
NIL |
13.2(Terminal Marking Plate) |
- |
100 |
|
NIL |
13.3(Marking ) |
- |
100 |
|
NIL |
13.4(Marking) |
- |
100 |
|
NIL |
13.4.1(Marking) |
- |
100 |
|
NIL |
14.1(MOUNTING ARRANGEMENT) |
- |
100 |
|
NIL |
14.2(MOUNTING ARRANGEMENT) |
- |
100 |
|
NIL |
14.3(MOUNTING ARRANGEMENT) |
- |
100 |
|
NIL |
14.4(MOUNTING ARRANGEMENT) |
- |
100 |
|
NIL |
15.1.1(TRANSFORMER TANK : Construction) |
- |
100 |
|
NIL |
15.1.2(TRANSFORMER TANK : Construction) |
- |
100 |
|
NIL |
15.1.3(TRANSFORMER TANK : Construction) |
- |
100 |
|
NIL |
15.1.4(TRANSFORMER TANK : Construction) |
- |
100 |
|
NIL |
15.1.5(TRANSFORMER TANK : Construction) |
- |
100 |
|
NIL |
21.2 a)(Measurement of winding resistance ) |
- |
4000 |
|
NIL |
21.2 b)( Measurement of voltage ratio and check of
phase displacemen) |
- |
4000 |
|
NIL |
21.2 c)( Measurement of short-circuit impedance
(principal tapping, when applicable) and load
loss at 50 percent and 100 percent load) |
- |
4000 |
|
NIL |
21.2 d)(Measurement of no-load loss and current) |
- |
4000 |
|
NIL |
21.2 e)(Measurement of insulation resistance) |
- |
2000 |
|
NIL |
21.2 f)(Induced over-voltage withstand test) |
- |
2000 |
|
NIL |
21.2 g)( Separate-source voltage withstand test) |
- |
2000 |
|
NIL |
21.5.3.3(Oil leakage test) |
- |
1000 |
|
NIL |
21.3(a )(Lightning impulse test) |
- |
5500 |
|
NIL |
21.3(b)(Temperature-rise test) |
- |
8000 |
|
NIL |
21.4 a)( Determination of sound levels) |
- |
2500 |
|
NIL |
21.5.1.1(Pressure test-Type test (For Transformers up to 200 kVA
)) |
- |
2500 |
|
NIL |
21.5.1.2(Pressure test-routine test (For Transformers up to 200 kVA
)) |
- |
2500 |
|
NIL |
21.5.2.1(Type test : For Transformers Above 200 kVA and Up to Including 2 500 kVA) |
- |
2500 |
|
NIL |
21.5.2.2(routine test :For Transformers Above 200 kVA and Up to Including 2 500 kVA) |
- |
2500 |
|
NIL |
21.5.2.3( Oil leakage test (routine test)) |
- |
2000 |
|
NIL |
21.5.3.1(For Single Phase Distribution Transformers Up to Including 25 kVA : pressure test (type test)) |
- |
2500 |
|
NIL |
21.5.3.2(For Single Phase Distribution Transformers Up to Including 25 kVA : pressure test (routine test)) |
- |
2500 |
|
NIL |
21.5.3.3(Oil leakage test (routine test)) |
- |
2500 |
|
NIL |
21.4 c(No load current at 112.5 percent voltage.) |
- |
45000 |
|
NIL |
21.4 d(Paint adhesion tests) |
- |
2500 |
|
NIL |
21.4 e(BDV and moisture content of oil in the transformer) |
- |
4000 |
|
NIL |
15.5(Total Dry Film Paint Thickness) |
- |
4000 |
|
NIL |
6.9, 7.9, 8.9(Permissible Flux Density and Over Fluxing) |
- |
2500 |
|
NIL |
11(Minimum clearance in Air) |
- |
1000 |
|
NIL |
16(Conservator for Non-sealed type Transformers) |
- |
1000 |
|
NIL |
20(Fittings) |
- |
1000 |
|
NIL |
6.8 (50%)(Total losses at 50 % load (Watts)) |
- |
2500 |
|
NIL |
7.8 (50%)(Total losses at 50 % load (Watts)) |
- |
2500 |
|
NIL |
8.8 (50%)(Total losses at 50 % load (Watts)) |
- |
2500 |
|
NIL |
6.8 (100%)(Total losses at 100 % load (Watts)) |
- |
2500 |
|
NIL |
7.8 (100%)(Total losses at 100 % load (Watts)) |
- |
2500 |
|
NIL |
8.8 (100%)(Total losses at 100 % load (Watts)) |
- |
2500 |
|
NIL |
21.5.1.3(Oil leakage test upto 200 KVA) |
- |
1000 |
|
NIL |
9.1a)(CRGO Electrical Steel) |
- |
200 |
|
NIL |
9.1 b)(Amorphous core material) |
- |
200 |
|
NIL |
9.1 c)(Copper/Aluminium conductor) |
- |
200 |
|
NIL |
9.1 d)(Kraft paper) |
- |
200 |
|
NIL |
9.1 e)(Press Board) |
- |
200 |
|
NIL |
9.1 f)(Mineral oil) |
- |
200 |
|
NIL |
10(Terminal Arrangement) |
- |
200 |
|
NIL |
15.2(Pressure and Vacuum Requirements) |
- |
200 |
|
NIL |
15.4(Gasket) |
- |
200 |
|
NIL |
19(Tolerances) |
- |
200 |
|
NIL |
18(Efficiency and regulation) |
- |
1000 |
|
NIL |
4(Service Conditions) |
- |
200 |
|
NIL |
5(General ) |
- |
200 |
|
NIL |
6.1(Rating) |
- |
200 |
|
NIL |
6.2(Rated frequency) |
- |
200 |
|
NIL |
6.3(Nominal system voltage) |
- |
200 |
|
NIL |
6.4(Basic Insulation level ) |
- |
200 |
|
NIL |
6.5(No-Load Voltage Ratios) |
- |
1000 |
|
NIL |
6.6(Winding connections and phase displacement) |
- |
2000 |
|
NIL |
6.7(Tapping Range and Tapping Method) |
- |
2000 |
|
NIL |
6.8(Losses and impedance values) |
- |
1000 |
|
NIL |
6.9(Permissible Flux Density and Over Fluxing ) |
- |
1000 |
|
NIL |
6.1(Limits of Temperature-rise) |
- |
2500 |
|
NIL |
7(Technical Parameters of three phase distribution trasnformers
higher than 200kva) |
- |
1000 |
|
NIL |
8(Technical Parameters of single phase distribution transformers
UP to and including 25 KVA ) |
- |
1000 |
|
NIL |
9(Standard Materials) |
- |
1000 |
|
NIL |
10(Terminal arrangment ) |
- |
1000 |
|
NIL |
11(Minimum Clearnaces air ) |
- |
1000 |
|
NIL |
12(Connectors ) |
- |
100 |
|
NIL |
13(Marking ) |
- |
100 |
|
NIL |
14(Mounting arrangement) |
- |
1000 |
|
NIL |
15(Trasnformer Tank ) |
- |
1000 |
|
NIL |
16(Conservator for Non-Sealed type Transformers) |
- |
200 |
|
NIL |
18(Efficiency and Regulation) |
- |
1000 |
|
NIL |
19(Tolerances) |
- |
200 |
|
NIL |
20(Fittings) |
- |
200 |
|
NIL |
21(General ) |
- |
200 |
|
NIL |
22(Information required with enquiry and order ) |
- |
200 |
|
NIL |
|
Complete
|
19 Jul, 2024 |
06 Jun, 2027 |
- included w.e.f.29.10.2024
Exclusion
CL 17 ( ABILITY OF TRANSFORMERS TO WITHSTAND EXTERNAL SHORT CIRCUIT )
CL 21.3(c) (Short-circuit withstand test)
CL 21.4 b (Short-circuit withstand test IS 2026 (Part 5) (above 200 kVA))
CL 17 (Ability of transformers to withstand external Short circuit ) |
7 |
STAR LABS TEST CENTRE LLP
| IS 1180 : Part 1 (2014) |
Outdoor Type Oil Immersed Distribution Transformers Upto and Including 2 500 kVA, 33kV - Specification Part 1 Mineral Oil Immersed (Fourth Revision) |
5 kVA to 2500 kVA ,upto 11kV ,22kV and 33kV/0.433 kV |
-
|
125000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
13.1(Marking (Rating Plates)) |
- |
0 |
|
- |
14.2(MOUNTING ARRANGEMENT) |
- |
0 |
|
- |
14.3(MOUNTING ARRANGEMENT) |
- |
0 |
|
- |
14.4(MOUNTING ARRANGEMENT) |
- |
0 |
|
- |
15.1.1(TRANSFORMER TANK : Construction) |
- |
0 |
|
- |
15.1.2(TRANSFORMER TANK : Construction) |
- |
0 |
|
- |
15.1.3(TRANSFORMER TANK : Construction) |
- |
0 |
|
- |
15.1.4(TRANSFORMER TANK : Construction) |
- |
0 |
|
- |
15.1.5(TRANSFORMER TANK : Construction) |
- |
0 |
|
- |
21.2 a)(Measurement of winding resistance ) |
- |
7000 |
|
- |
21.2 b)( Measurement of voltage ratio and check of
phase displacemen) |
- |
5500 |
|
- |
21.2 c)( Measurement of short-circuit impedance
(principal tapping, when applicable) and load
loss at 50 percent and 100 percent load) |
- |
5500 |
|
- |
21.2 d)(Measurement of no-load loss and current) |
- |
3500 |
|
- |
21.2 e)(Measurement of insulation resistance) |
- |
2500 |
|
- |
21.2 f)(Induced over-voltage withstand test) |
- |
4500 |
|
- |
21.2 g)( Separate-source voltage withstand test) |
- |
4000 |
|
- |
21.5.1.1(Pressure test-Type test (For Transformers up to 200 kVA
)) |
- |
7000 |
|
- |
21.5.1.2(Pressure test-routine test (For Transformers up to 200 kVA
)) |
- |
7000 |
|
- |
21.5.2.1(Type test : For Transformers Above 200 kVA and Up to Including 2 500 kVA) |
- |
7999.99 |
|
- |
21.5.2.2(routine test :For Transformers Above 200 kVA and Up to Including 2 500 kVA) |
- |
8000 |
|
- |
21.5.2.3( Oil leakage test (routine test)) |
- |
8000 |
|
- |
21.5.3.1(For Single Phase Distribution Transformers Up to Including 25 kVA : pressure test (type test)) |
- |
5999.99 |
|
- |
21.5.3.2(For Single Phase Distribution Transformers Up to Including 25 kVA : pressure test (routine test)) |
- |
6000 |
|
- |
21.5.3.3(Oil leakage test (routine test)) |
- |
7000 |
|
- |
15.5(Total Dry Film Paint Thickness) |
- |
0 |
|
- |
6.9, 7.9, 8.9(Permissible Flux Density and Over Fluxing) |
- |
0 |
|
- |
11(Minimum clearance in Air) |
- |
0 |
|
- |
16(Conservator for Non-sealed type Transformers) |
- |
0 |
|
- |
20(Fittings) |
- |
0 |
|
- |
6.8 (50%)(Total losses at 50 % load (Watts)) |
- |
0 |
|
- |
7.8 (50%)(Total losses at 50 % load (Watts)) |
- |
0 |
|
- |
8.8 (50%)(Total losses at 50 % load (Watts)) |
- |
0 |
|
- |
6.8 (100%)(Total losses at 100 % load (Watts)) |
- |
0 |
|
- |
8.8 (100%)(Total losses at 100 % load (Watts)) |
- |
0 |
|
- |
21.5.1.3(Oil leakage test upto 200 KVA) |
- |
7000 |
|
- |
9.1a)(CRGO Electrical Steel) |
- |
0 |
|
- |
9.1 b)(Amorphous core material) |
- |
0 |
|
- |
13.2(Terminal Marking Plate) |
- |
0 |
|
- |
13.3(Marking ) |
- |
0 |
|
- |
13.4(Marking) |
- |
0 |
|
- |
13.4.1(Marking) |
- |
0 |
|
- |
14.1(MOUNTING ARRANGEMENT) |
- |
0 |
|
- |
21(General ) |
- |
0 |
|
- |
21.3(a )(Lightning impulse test) |
- |
40000 |
|
- |
21.3(b)(Temperature-rise test) |
- |
24000 |
|
- |
21.4 c(No load current at 112.5 percent voltage.) |
- |
1000 |
|
- |
10(Terminal Arrangement) |
- |
0 |
|
- |
15.2(Pressure and Vacuum Requirements) |
- |
0 |
|
- |
19(Tolerances) |
- |
0 |
|
- |
18(Efficiency and regulation) |
- |
0 |
|
- |
4(Service Conditions) |
- |
0 |
|
- |
5(General ) |
- |
0 |
|
- |
6.1(Rating) |
- |
0 |
|
- |
6.2(Rated frequency) |
- |
0 |
|
- |
6.3(Nominal system voltage) |
- |
0 |
|
- |
6.4(Basic Insulation level ) |
- |
0 |
|
- |
6.5(No-Load Voltage Ratios) |
- |
0 |
|
- |
6.6(Winding connections and phase displacement) |
- |
0 |
|
- |
6.7(Tapping Range and Tapping Method) |
- |
0 |
|
- |
6.8(Losses and impedance values) |
- |
0 |
|
- |
6.9(Permissible Flux Density and Over Fluxing ) |
- |
0 |
|
- |
6.1(Limits of Temperature-rise) |
- |
0 |
|
- |
7(Technical Parameters of three phase distribution trasnformers
higher than 200kva) |
- |
0 |
|
- |
8(Technical Parameters of single phase distribution transformers
UP to and including 25 KVA ) |
- |
0 |
|
- |
9(Standard Materials) |
- |
0 |
|
- |
11(Minimum Clearnaces air ) |
- |
0 |
|
- |
12(Connectors ) |
- |
0 |
|
- |
13(Marking ) |
- |
0 |
|
- |
14(Mounting arrangement) |
- |
0 |
|
- |
15(Trasnformer Tank ) |
- |
0 |
|
- |
16(Conservator for Non-Sealed type Transformers) |
- |
0 |
|
- |
20(Fittings) |
- |
0 |
|
- |
22(Information required with enquiry and order ) |
- |
0 |
|
- |
19(Tolerances) |
- |
0 |
|
- |
10(Terminal arrangment ) |
- |
0 |
|
- |
18(Efficiency and Regulation) |
- |
0 |
|
- |
7.8 (100%)(Total losses at 100 % load (Watts)) |
- |
0 |
|
- |
17( ABILITY OF TRANSFORMERS TO
WITHSTAND EXTERNAL SHORT CIRCUIT
) |
- |
0 |
|
- |
21.5.3.3(Oil leakage test) |
- |
0 |
|
- |
|
Complete
|
|
07 Oct, 2027 |
- Exclusion: 21.3(c) (Short-circuit withstand test), 21.4 a) ( Determination of sound levels), 21.4 d (Paint adhesion tests), 21.4 e (BDV and moisture content of oil in the transformer), 17 (Ability of transformers to withstand external Short circuit ) |
8 |
Advance Electrical Testing And Calibration Lab LLP
| IS 1180 : Part 3 (2021) |
Outdoor/Indoor Type Liquid Immersed Distribution Transformers Up to and Including 2 500 kVA, 33 kV — Specification Part 3 Natural/Synthetic Organic Ester Liquid Immersed |
upto 2500 kVA, 33 kV |
-
|
72205 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
21.2 a(Measurement of winding resistance
[IS 2026 (Part 1)].) |
- |
785 |
|
10 % Discount for BIS |
21.2 b(Measurement of voltage ratio and check of phase
displacement [IS 2026 (Part 1)].) |
- |
910 |
|
10 % Discount for BIS |
21.2 c(Measurement of short-circuit impedance
(principal tapping, when applicable) and load
loss at 50 percent and 100 percent load
[IS 2026 (Part 1)].) |
- |
7430 |
|
10 % Discount for BIS |
21.2 d(Measurement of no-load loss and current
[IS 2026 (Part 1)].) |
- |
5950 |
|
10 % Discount for BIS |
21.2 e(Measurement of insulation resistance
[IS 2026 (Part 1)].) |
- |
570 |
|
10 % Discount for BIS |
21.2 f(Induced over-voltage withstand test
[IS 2026 (Part 3)].) |
- |
1240 |
|
10 % Discount for BIS |
21.2 g(Separate-source voltage withstand test
[IS 2026 (Part 3)]) |
- |
1240 |
|
10 % Discount for BIS |
21.5(Pressure and Ester Liquid Leakage Test) |
- |
5950 |
|
10 % Discount for BIS |
21.3 b(Temperature-rise test [IS 2026 (Part 2)].) |
- |
28230 |
|
10 % Discount for BIS |
21.4 a(Determination of sound levels [IS 2026 (Part 10)];) |
- |
2600 |
|
10 % Discount for BIS |
21.4 c(No load current at 112.5 percent voltage
(see 6.9.2, 7.9.2, 8.9.2);) |
- |
1590 |
|
10 % Discount for BIS |
21.4 e(BDV and Moisture content of liquid in the
transformer (IS 16081, IS 16099, IS 16899 or
IS 16659, whichever is applicable).) |
- |
800 |
|
10 % Discount for BIS |
21.4 d(Paint adhesion test — The test is performed as
per ASTM D3359 (Standard Test Methods for
measuring adhesion by tape test).) |
- |
5010 |
|
10 % Discount for BIS |
6.1 Table 1(Standard Ratings) |
- |
0 |
|
NA |
6.2, 7.2, 8.2(Rated Frequency) |
- |
0 |
|
NA |
6.3, 7.3(Nominal System Voltage) |
- |
0 |
|
NA |
6.4(Table 2 Minimum Basic Insulation Level) |
- |
0 |
|
NA |
6.5, 7.5(No-Load Voltage Ratios) |
- |
0 |
|
NA, Already mentioned as above |
6.6, 7.6(Winding Connections and Phase Displacement) |
- |
0 |
|
NA, Already mentioned as above |
6.7(Tapping Range and Tapping Methods) |
- |
0 |
|
na |
6.8(Table 3 Losses and Impedance Values) |
- |
0 |
|
NA, Already mentioned as above |
6.9(Permissible Flux Density and Over Fluxing) |
- |
0 |
|
na |
6.10(Limits of Temperature-rise) |
- |
0 |
|
NA, Already mentioned as above |
7.1(Table 4 Standard Ratings) |
- |
0 |
|
na |
7.4(Table 5 Minimum Basic Insulation Level) |
- |
0 |
|
na |
7.7(Tapping Ranges and Tapping Methods) |
- |
0 |
|
na |
7.8(Losses and Impedance Values) |
- |
0 |
|
NA, Already mentioned as above |
7.9(Permissible Flux Density and Overfluxing) |
- |
0 |
|
na |
7.10(Limits of Temperature Rise) |
- |
0 |
|
NA, Already mentioned as above |
8.1 Table 7(Standard Ratings) |
- |
0 |
|
na |
8.3(Nominal System Voltage) |
- |
0 |
|
na |
8.5(No Load Voltage Ratio) |
- |
0 |
|
NA |
8.6(Number of Phases and Polarity) |
- |
0 |
|
NA |
8.4(Table 8 Minimum Basic Insulation Level) |
- |
0 |
|
NA |
8.8(Losses and Impedance Values) |
- |
0 |
|
NA, Already mentioned as above |
8.9(Permissible Flux Density and Overfluxing) |
- |
0 |
|
NA |
8.10(Limits of Temperature Rise) |
- |
0 |
|
NA, Already mentioned as above |
9(Standard Materials) |
- |
0 |
|
NA |
10(Terminal Arrangement) |
- |
0 |
|
NA |
11(Minimum clearances in air) |
- |
0 |
|
NA |
12(Connectors (Applicable for bare bushing terminations only)) |
- |
0 |
|
NA |
13(Marking) |
- |
0 |
|
NA |
14(Mounting Arrangement) |
- |
0 |
|
NA |
15(Transformer Tank) |
- |
0 |
|
NA |
16(Conservator for non-sealed typetransformers) |
- |
0 |
|
NA |
18(Efficiency and regulation) |
- |
0 |
|
NA |
20(Fittings) |
- |
0 |
|
NA |
6.1(Rating) |
- |
0 |
|
NA |
6.2(Rated Frequceny) |
- |
0 |
|
NA |
6.3(Nominal System Voltage) |
- |
0 |
|
NA |
6.4(Basic Insulation Level) |
- |
0 |
|
NA |
6.5(No-Load Voltage Ratios) |
- |
0 |
|
NA, Already mentioned as above |
6.6(Winding connection and phase displacement) |
- |
0 |
|
NA, Already mentioned as above |
6.7(Tapping range and tapping methods) |
- |
0 |
|
NA |
6.8(Losses and Impedance Value) |
- |
0 |
|
NA, Already mentioned as above |
6.9(Permissible flux density and over fluxing) |
- |
0 |
|
NA |
6.10(Limits of temperature-rise) |
- |
0 |
|
NA, Already mentioned as above |
7("Technical parameters of three phase distribution
transformers higher ") |
- |
0 |
|
NA |
8(Technical parameter of single phase distribution transformers) |
- |
0 |
|
NA |
10(Terminal Arrangement) |
- |
0 |
|
NA, Already mentioned as above |
11(Minimum clearances in air) |
- |
0 |
|
NA |
12(Connectors for bare bushing terminations) |
- |
0 |
|
NA |
13(Marking) |
- |
0 |
|
NA |
15(Trasnformer tank) |
- |
0 |
|
NA |
16(Conservator for non-sealed type transformers) |
- |
0 |
|
NA |
18(Efficiency and regulations) |
- |
0 |
|
NA |
20(Fittings) |
- |
0 |
|
NA |
21.2(Routine Tests) |
- |
0 |
|
NA, Already mentioned as above |
21.4(Special Test) |
- |
0 |
|
NA, Already mentioned as above |
22(Information required with enquiry and order) |
- |
0 |
|
NA |
14(Mounting Arrangement) |
- |
0 |
|
NA |
21.3 d(Pressure test) |
- |
0 |
|
NA, Already mentioned as above |
21.1(General) |
- |
0 |
|
NA |
|
Complete
|
18 Nov, 2024 |
17 Nov, 2027 |
- Lightning Impulse test, short circuit withstand tests, short circuit withstand test, moisture contant of in the transformer, Ester liquid leakage test |
9 |
Advance Electrical Testing And Calibration Lab LLP
| IS 1180 : Part 1 (2014) |
Outdoor Type Oil Immersed Distribution Transformers Upto and Including 2 500 kVA, 33kV - Specification Part 1 Mineral Oil Immersed (Fourth Revision) |
2500KVA, 11-0.433KV Three Phase Distribution Transforme |
-
|
78155 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
21.2 a)(Measurement of winding resistance ) |
- |
785 |
|
10 % Discount for BIS |
21.2 b)( Measurement of voltage ratio and check of
phase displacemen) |
- |
909.98 |
|
10 % Discount for BIS |
21.2 c)( Measurement of short-circuit impedance
(principal tapping, when applicable) and load
loss at 50 percent and 100 percent load) |
- |
7430 |
|
10 % Discount for BIS |
21.2 d)(Measurement of no-load loss and current) |
- |
5950 |
|
10 % Discount for BIS |
21.2 e)(Measurement of insulation resistance) |
- |
570 |
|
10 % Discount for BIS |
21.2 f)(Induced over-voltage withstand test) |
- |
1240 |
|
10 % Discount for BIS |
21.2 g)( Separate-source voltage withstand test) |
- |
1240 |
|
10 % Discount for BIS |
21.5.1.2(Pressure test-routine test (For Transformers up to 200 kVA
)) |
- |
5950 |
|
10 % Discount for BIS |
21.3(b)(Temperature-rise test) |
- |
28230 |
|
10 % Discount for BIS |
21.4 a)( Determination of sound levels) |
- |
2600 |
|
10 % Discount for BIS |
21.4 d(Paint adhesion tests) |
- |
5010 |
|
10 % Discount for BIS |
21.4 e(BDV and moisture content of oil in the transformer) |
- |
799.99 |
|
10 % Discount for BIS |
21.5.3.3(Oil leakage test) |
- |
5950 |
|
10 % Discount for BIS |
21.5.1.1(Pressure test-Type test (For Transformers up to 200 kVA
)) |
- |
9899.99 |
|
10 % Discount for BIS |
21.4 c(No load current at 112.5 percent voltage.) |
- |
1590 |
|
10 % Discount for BIS |
13.1(Marking (Rating Plates)) |
- |
0 |
|
NA |
13.2(Terminal Marking Plate) |
- |
0 |
|
NA |
21.5.2.3( Oil leakage test (routine test)) |
- |
0 |
|
NA, Already mentioned above. |
21.5.3.1(For Single Phase Distribution Transformers Up to Including 25 kVA : pressure test (type test)) |
- |
0 |
|
NA, Already mentioned above. |
21.5.3.2(For Single Phase Distribution Transformers Up to Including 25 kVA : pressure test (routine test)) |
- |
0 |
|
NA, Already mentioned above. |
11(Minimum clearance in Air) |
- |
0 |
|
NA, Already mentioned above. |
6.8 (50%)(Total losses at 50 % load (Watts)) |
- |
0 |
|
NA, Already mentioned above. |
7.8 (50%)(Total losses at 50 % load (Watts)) |
- |
0 |
|
NA, Already mentioned above. |
8.8 (50%)(Total losses at 50 % load (Watts)) |
- |
0 |
|
NA, Already mentioned above. |
6.8 (100%)(Total losses at 100 % load (Watts)) |
- |
0 |
|
NA, Already mentioned above. |
7.8 (100%)(Total losses at 100 % load (Watts)) |
- |
0 |
|
NA, Already mentioned above. |
8.8 (100%)(Total losses at 100 % load (Watts)) |
- |
0 |
|
NA, Already mentioned above. |
21.5.1.3(Oil leakage test upto 200 KVA) |
- |
0 |
|
NA, Already mentioned above. |
15.2(Pressure and Vacuum Requirements) |
- |
0 |
|
NA, Already mentioned above. |
6.4(Basic Insulation level ) |
- |
0 |
|
NA |
6.5(No-Load Voltage Ratios) |
- |
0 |
|
NA, Already mentioned above. |
6.6(Winding connections and phase displacement) |
- |
0 |
|
NA, Already mentioned above. |
6.8(Losses and impedance values) |
- |
0 |
|
NA, Already mentioned above. |
6.1(Limits of Temperature-rise) |
- |
0 |
|
NA, Already mentioned above. |
11(Minimum Clearnaces air ) |
- |
0 |
|
NA |
13(Marking ) |
- |
0 |
|
NA |
13.3(Marking ) |
- |
0 |
|
NA |
13.4(Marking) |
- |
0 |
|
NA |
13.4.1(Marking) |
- |
0 |
|
NA |
14.1(MOUNTING ARRANGEMENT) |
- |
0 |
|
NA |
14.2(MOUNTING ARRANGEMENT) |
- |
0 |
|
NA |
14.3(MOUNTING ARRANGEMENT) |
- |
0 |
|
NA |
14.4(MOUNTING ARRANGEMENT) |
- |
0 |
|
NA |
15.1.1(TRANSFORMER TANK : Construction) |
- |
0 |
|
NA |
15.1.2(TRANSFORMER TANK : Construction) |
- |
0 |
|
NA |
15.1.3(TRANSFORMER TANK : Construction) |
- |
0 |
|
NA |
15.1.4(TRANSFORMER TANK : Construction) |
- |
0 |
|
NA |
15.1.5(TRANSFORMER TANK : Construction) |
- |
0 |
|
NA |
15.5(Total Dry Film Paint Thickness) |
- |
0 |
|
NA, Already mentioned above. |
16(Conservator for Non-sealed type Transformers) |
- |
0 |
|
NA |
20(Fittings) |
- |
0 |
|
NA |
10(Terminal Arrangement) |
- |
0 |
|
NA |
6.1(Rating) |
- |
0 |
|
NA |
6.2(Rated frequency) |
- |
0 |
|
NA |
6.3(Nominal system voltage) |
- |
0 |
|
NA |
10(Terminal arrangment ) |
- |
0 |
|
NA |
12(Connectors ) |
- |
0 |
|
NA |
14(Mounting arrangement) |
- |
0 |
|
NA |
15(Trasnformer Tank ) |
- |
0 |
|
NA |
16(Conservator for Non-Sealed type Transformers) |
- |
0 |
|
NA |
18(Efficiency and regulation) |
- |
0 |
|
NA |
20(Fittings) |
- |
0 |
|
NA |
21.5.2.2(routine test :For Transformers Above 200 kVA and Up to Including 2 500 kVA) |
- |
0 |
|
NA, Already mentioned above. |
21.5.3.3(Oil leakage test (routine test)) |
- |
0 |
|
NA, Already mentioned above. |
18(Efficiency and Regulation) |
- |
0 |
|
NA |
6.7(Tapping Range and Tapping Method) |
- |
0 |
|
NA |
|
Complete
|
18 Nov, 2024 |
17 Nov, 2027 |
- Lightning Impulse test, short circuit withstand tests, short circuit withstand test, moisture contant of in the transformer |
10 |
Electrical Research and Development Association, gujarat
| IS 1180 : Part 3 (2021) |
Outdoor/Indoor Type Liquid Immersed Distribution Transformers Up to and Including 2 500 kVA, 33 kV — Specification Part 3 Natural/Synthetic Organic Ester Liquid Immersed |
- |
-
|
1115845 View breakup
Up to 200 kVA (For single phase and Three phase)
10 kVA for routine test - Rs.11,950/-, for type test - Rs.99,200/-(including Short circuit test), for special test - Rs.7,000/-, For complete testing with short circuit – Rs.1,18,150/-;
16 kVA for routine test - Rs.12,350/-, for type test - Rs.1,00,200/-(including Short circuit test), for special test - Rs.7,000/-, For complete testing with short circuit – Rs.1,19,550/-;
25 kVA for routine test - Rs.12,850/-, for type test - Rs.1,01,200/-(including Short circuit test), for special test - Rs.7,000/-, For complete testing with short circuit – Rs.1,21,050/-;
63 kVA for routine test - Rs.13,850/-, for type test - Rs.1,06,700/-(including Short circuit test), for special test - Rs.7,000/-, For complete testing with short circuit – Rs.1,27,550/-;
100 kVA for routine test - Rs.14,850/-, for type test - Rs.1,08,700/-(including Short circuit test), for special test - Rs.7,000/-, For complete testing with short circuit – Rs.1,30,550/-;
160 kVA (without tap) for routine test - Rs.15,850/-, for type test - Rs.1,27,500/-(including Short circuit test), for special test - Rs.7,000/-, For complete testing with short circuit – Rs.1,50,350/-;
160 kVA (Up to 4 tap) for routine test - Rs.18,700/-, for type test - Rs. 1,27,500/-(including Short circuit test), for special test - Rs.7,000/-, For complete testing with short circuit – Rs.1,53,200/-;
160 kVA (Up to 7 tap) for routine test - Rs.21,550/-, for type test - Rs. 1,27,500/-(including Short circuit test), for special test - Rs.7,000/-, For complete testing with short circuit – Rs.1,56,050/-;
160 kVA (Up to 9 tap) for routine test - Rs.23,450/-, for type test - Rs. 1,27,500/-(including Short circuit test), for special test - Rs.7,000/-, For complete testing with short circuit – Rs.1,56,950/-;
200 kVA (without tap) for routine test - Rs.16,350/-, for type test - Rs.1,35,200/-(including Short circuit test), for special test - Rs.7,000/-, For complete testing with short circuit – Rs.1,57,000/-;
200 kVA (Up to 4 tap) for routine test - Rs.19,200/-, for type test - Rs.1,35,200/-(including Short circuit test), for special test - Rs.7,000/-, For complete testing with short circuit – Rs. 1,57,000/-;
200 kVA (Up to 7 tap) for routine test - Rs.22,050/-, for type test - Rs.1,35,200/-(including Short circuit test), for special test - Rs.7,000/-, For complete testing with short circuit – Rs. 1,57,000/-;
200 kVA (Up to 9 tap) for routine test - Rs.23,950/-, for type test - Rs.1,35,200/-(including Short circuit test), for special test - Rs.7,000/-, For complete testing with short circuit – Rs. 1,57,000/-;
Above 200 kVA up to 2500 kVA (Three phase transformer)
250 kVA (Without tap) for routine test - Rs.16,850/-, for type test - Rs.50,000/-, for special test - Rs.7,000/-(Excluding Short circuit test), For complete testing without short circuit – Rs.73,850/-;
250 kVA (Up to 4 Tap) for routine test - Rs.19,700/-, for type test - Rs.50,000/-, for special test - Rs.7,000/-(Excluding Short circuit test), For complete testing without short circuit – Rs.76,700/-;
250 kVA (Up to 7 Tap) for routine test - Rs.22,550/-, for type test - Rs.50,000/-, for special test - Rs.7,000/-(Excluding Short circuit test), For complete testing without short circuit – Rs.79,550/-;
250 kVA (Up to 9 Tap) for routine test - Rs.24,450/-, for type test - Rs.50,000/-, for special test - Rs.7,000/-(Excluding Short circuit test), For complete testing without short circuit – Rs.81,450/-;
250 kVA (Up to 17 Tap) for routine test - Rs.32,050/-, for type test - Rs.50,000/-, for special test - Rs.7,000/-(Excluding Short circuit test), For complete testing without short circuit – Rs.89,050/-;
315 kVA (Without tap) for routine test - Rs.17,600/-, for type test - Rs.54,000/-, for special test - Rs.7,000/-(Excluding Short circuit test), For complete testing without short circuit – Rs.78,600/-;
315 kVA (Up to 4 tap) for routine test - Rs.20,450/-, for type test - Rs.54,000/-, for special test - Rs.7,000/-(Excluding Short circuit test), For complete testing without short circuit – Rs.81,450/-;
315 kVA (UP to 7 tap) for routine test - Rs.23,300/-, for type test - Rs.54,000/-, for special test - Rs.7,000/-(Excluding Short circuit test), For complete testing without short circuit – Rs.84,300/-;
315 kVA (Up to 9 tap) for routine test - Rs.25,200/-, for type test - Rs.54,000/-, for special test - Rs.7,000/-(Excluding Short circuit test), For complete testing without short circuit – Rs.86,200/-;
315 kVA (Up to 17 tap) for routine test - Rs.32,800/-, for type test - Rs.54,000/-, for special test - Rs.7,000/-(Excluding Short circuit test), For complete testing without short circuit – Rs.93,800/-;
400 kVA (Without tap) for routine test - Rs.17,600/-, for type test - Rs.54,000/-, for special test - Rs.7,000/-(Excluding Short circuit test), For complete testing without short circuit – Rs.78,600/-;
400 kVA (Up to 4 tap) for routine test - Rs.20,450/-, for type test - Rs.54,000/-, for special test - Rs.7,000/-(Excluding Short circuit test), For complete testing without short circuit – Rs.81,450/-;
400 kVA (UP to 7 tap) for routine test - Rs.23,300/-, for type test - Rs.54,000/-, for special test - Rs.7,000/-(Excluding Short circuit test), For complete testing without short circuit – Rs.84,300/-;
400 kVA (Up to 9 tap) for routine test - Rs.25,200/-, for type test - Rs.54,000/-, for special test - Rs.7,000/-(Excluding Short circuit test), For complete testing without short circuit – Rs.86,200/-;
400 kVA (Up to 17 tap) for routine test - Rs.32,800/-, for type test - Rs.54,000/-, for special test - Rs.7,000/-(Excluding Short circuit test), For complete testing without short circuit – Rs.93,800/-;
500 kVA (Without tap) for routine test - Rs.18,600/-, for type test - Rs.54,000/-, for special test - Rs.7,000/-(Excluding Short circuit test), For complete testing without short circuit – Rs.79,600/-;
500 kVA (Up to 4 tap) for routine test - Rs.21,450/-, for type test - Rs.54,000/-, for special test - Rs.7,000/-(Excluding Short circuit test), For complete testing without short circuit – Rs.82,450/-;
500 kVA (Up to 7 tap) for routine test - Rs.24,300/-, for type test - Rs.54,000/-, for special test - Rs.7,000/-(Excluding Short circuit test), For complete testing without short circuit – Rs.85,300/-;
500 kVA (Up to 9 tap) for routine test - Rs.26,200/-, for type test - Rs.54,000/-, for special test - Rs.7,000/-(Excluding Short circuit test), For complete testing without short circuit – Rs.87,200/-;
500 kVA (Up to 17 tap) for routine test - Rs.33,800/-, for type test - Rs.54,000/-, for special test - Rs.7,000/-(Excluding Short circuit test), For complete testing without short circuit – Rs.94,800/-;
630 kVA (Without tap) for routine test - Rs.19,400/-, for type test - Rs.67,000/-, for special test - Rs.7,000/-(Excluding Short circuit test), For complete testing without short circuit – Rs.93,400/-;
630 kVA (Up to 4 tap) for routine test - Rs.22,250/-, for type test - Rs.67,000/-, for special test - Rs.7,000/-(Excluding Short circuit test), For complete testing without short circuit – Rs.92,250/-;
630 kVA (Up to 7 tap) for routine test - Rs.25,100/-, for type test - Rs.67,000/-, for special test - Rs.7,000/-(Excluding Short circuit test), For complete testing without short circuit – Rs.99,100/-;
630 kVA (Up to 9 tap) for routine test - Rs.27,000/-, for type test - Rs.67,000/-, for special test - Rs.7,000/-(Excluding Short circuit test), For complete testing without short circuit – Rs.1,01,000/-;
630 kVA (Up to 17 tap) for routine test - Rs.34,600/-, for type test - Rs.67,000/-, for special test - Rs.7,000/-(Excluding Short circuit test), For complete testing without short circuit – Rs.1,08,600/-;
750 kVA (Without tap) for routine test - Rs.20,700/-, for type test - Rs.67,000/-, for special test - Rs.7,000/-(Excluding Short circuit test), For complete testing without short circuit – Rs.94,700/-;
750 kVA (Up to 4 tap) for routine test - Rs.23,550/-, for type test - Rs.67,000/-, for special test - Rs.7,000/-(Excluding Short circuit test), For complete testing without short circuit – Rs.97,550/-;
750 kVA (Up to 7 tap) for routine test - Rs.26,400/-, for type test - Rs.67,000/-, for special test - Rs.7,000/-(Excluding Short circuit test), For complete testing without short circuit – Rs.1,00,400/-;
750 kVA (Up to 9 tap) for routine test - Rs.28,300/-, for type test - Rs.67,000/-, for special test - Rs.7,000/-(Excluding Short circuit test), For complete testing without short circuit – Rs.1,02,300/-;
750 kVA (Up to 17 tap) for routine test - Rs.35,900/-, for type test - Rs.67,000/-, for special test - Rs.7,000/-(Excluding Short circuit test), For complete testing without short circuit – Rs.1,09,900/-;
751 to 1000 kVA (Without tap) for routine test - Rs.21,800/-, for type test - Rs.67,000/-, for special test - Rs.7,000/-(Excluding Short circuit test), For complete testing without short circuit – Rs.95,800/-;
751 to 1000 kVA (Up to 4 tap) for routine test - Rs.24,650/-, for type test - Rs.67,000/-, for special test - Rs.7,000/-(Excluding Short circuit test), For complete testing without short circuit – Rs.98,650/-;
751 to 1000 kVA (Up to 7 tap) for routine test - Rs.27,500/-, for type test - Rs.67,000/-, for special test - Rs.7,000/-(Excluding Short circuit test), For complete testing without short circuit – Rs.1,01,500/-;
751 to 1000 kVA (Up to 9 tap) for routine test - Rs.29,400/-, for type test - Rs.67,000/-, for special test - Rs.7,000/-(Excluding Short circuit test), For complete testing without short circuit – Rs.1,03,400/-;
751 to 1000 kVA (Up to 17 tap) for routine test - Rs.37,000/-, for type test - Rs.67,000/-, for special test - Rs.7,000/-(Excluding Short circuit test), For complete testing without short circuit – Rs.1,11,000/-;
1250 kVA (Without tap) for routine test - Rs.23,200/-, for type test - Rs.79,000/-, for special test - Rs.7,000/-(Excluding Short circuit test), For complete testing without short circuit – Rs.1,09,200/-;
1250 kVA (Up to 4 tap) for routine test - Rs.26,050/-, for type test - Rs.79,000/-, for special test - Rs.7,000/-(Excluding Short circuit test), For complete testing without short circuit – Rs.1,12,050/-;
1250 kVA (Up to 7 tap) for routine test - Rs.28,900/-, for type test - Rs.79,000/-, for special test - Rs.7,000/-(Excluding Short circuit test), For complete testing without short circuit – Rs.1,14,900/-;
1250 kVA (Up to 9 tap) for routine test - Rs.30,800/-, for type test - Rs.79,000/-, for special test - Rs.7,000/-(Excluding Short circuit test), For complete testing without short circuit – Rs.1,16,800/-;
1250 kVA (Up to 17 tap) for routine test - Rs.38,400/-, for type test - Rs.79,000/-, for special test - Rs.7,000/-(Excluding Short circuit test), For complete testing without short circuit – Rs.1,24,400/-;
1600 kVA (Without tap) for routine test - Rs.23,550/-, for type test - Rs.79,000/-, for special test - Rs.7,000/-(Excluding Short circuit test), For complete testing without short circuit – Rs.1,09,550/-;
1600 kVA (Up to 4 tap) for routine test - Rs.26,900/-, for type test - Rs.79,000/-, for special test - Rs.7,000/-(Excluding Short circuit test), For complete testing without short circuit – Rs.1,12,900/-;
1600 kVA (Up to 7 tap) for routine test - Rs.29,750/-, for type test - Rs.79,000/-, for special test - Rs.7,000/-(Excluding Short circuit test), For complete testing without short circuit – Rs.1,15,750/-;
1600 kVA (Up to 9 tap) for routine test - Rs.31,650/-, for type test - Rs.79,000/-, for special test - Rs.7,000/-(Excluding Short circuit test), For complete testing without short circuit – Rs.1,17,650/-;
1600 kVA (Up to 17 tap) for routine test - Rs.39,250/-, for type test - Rs.79,000/-, for special test - Rs.7,000/-(Excluding Short circuit test), For complete testing without short circuit – Rs.1,25,250/-;
2000 kVA (Without tap) for routine test - Rs.24,200/-, for type test - Rs.79,000/-, for special test - Rs.7,000/-(Excluding Short circuit test), For complete testing without short circuit – Rs.1,10,200/-;
2000 kVA (Up to 4 tap) for routine test - Rs.27,550/-, for type test - Rs.79,000/-, for special test - Rs.7,000/-(Excluding Short circuit test), For complete testing without short circuit – Rs.1,13,550/-;
2000 kVA (Up to 7 tap) for routine test - Rs.30,400/-, for type test - Rs.79,000/-, for special test - Rs.7,000/-(Excluding Short circuit test), For complete testing without short circuit – Rs.1,16,400/-;
2000 kVA (Up to 9 tap) for routine test - Rs.32,300/-, for type test - Rs.79,000/-, for special test - Rs.7,000/-(Excluding Short circuit test), For complete testing without short circuit – Rs.1,18,300/-;
2000 kVA (Up to 17 tap) for routine test - Rs.39,900/-, for type test - Rs.79,000/-, for special test - Rs.7,000/-(Excluding Short circuit test), For complete testing without short circuit – Rs.1,25,900/-;
2500 kVA (Without tap) for routine test - Rs.24,550/-, for type test - Rs.79,000/-, for special test - Rs.7,000/-(Excluding Short circuit test), For complete testing without short circuit – Rs.1,10,550/-;
2500 kVA (Up to 4 tap) for routine test - Rs.27,900/-, for type test - Rs.79,000/-, for special test - Rs.7,000/-(Excluding Short circuit test), For complete testing without short circuit – Rs.1,13,900/-;
2500 kVA (Up to 7 tap) for routine test - Rs.30,750/-, for type test - Rs.79,000/-, for special test - Rs.7,000/-(Excluding Short circuit test), For complete testing without short circuit – Rs.1,16,750/-;
2500 kVA (Up to 9 tap) for routine test - Rs.32,650/-, for type test - Rs.79,000/-, for special test - Rs.7,000/-(Excluding Short circuit test), For complete testing without short circuit – Rs.1,18,650/-;
2500 kVA (Up to 17 tap) for routine test - Rs.40,250/-, for type test - Rs.79,000/-, for special test - Rs.7,000/-(Excluding Short circuit test), For complete testing without short circuit – Rs.1,26,250/-;
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
21.2 a(Measurement of winding resistance
[IS 2026 (Part 1)].) |
- |
6839 |
|
For 1 & 3 phase
- up to 2500 KVA Rs. 759
For subsequent taps (per tap charges)
- up to 2500 KVA Rs. 380
Rs. 6839 CONSIDERING 2500 KVA TRANSFORMER 17 TAPS |
21.2 b(Measurement of voltage ratio and check of phase
displacement [IS 2026 (Part 1)].) |
- |
9108 |
|
For 1 & 3 phase
- up to 2500 KVA Rs. 1012
For subsequent taps (per tap charges)
- up to 2500 KVA Rs. 506
Rs. 6839 CONSIDERING 2500 KVA TRANSFORMER 17 TAPS |
21.2 c(Measurement of short-circuit impedance
(principal tapping, when applicable) and load
loss at 50 percent and 100 percent load
[IS 2026 (Part 1)].) |
- |
22138 |
|
For 1 & 3 phase
- UPTO 100 KVA Rs. 3036
- Above 100 KVA - 500 KVA Rs. 4744
- Above 500 KVA - 2500 KVA Rs. 9488
For subsequent taps (per tap charges)
- UPTO 100 KVA Rs. 2024
- Above 100 KVA - 500 KVA Rs. 3163
- Above 500 KVA - 2500 KVA Rs. 6325 |
21.2 d(Measurement of no-load loss and current
[IS 2026 (Part 1)].) |
- |
6325 |
|
For 1 & 3 phase
- UPTO 100 KVA Rs. 2024
- Above 100 KVA - 500 KVA Rs. 3163
- Above 500 KVA - 2500 KVA Rs. 6325
For subsequent taps (per tap charges)
- UPTO 100 KVA Rs. 1012
- Above 100 KVA - 500 KVA Rs. 1581
- Above 500 KVA - 2500 KVA Rs. 3163 |
21.2 e(Measurement of insulation resistance
[IS 2026 (Part 1)].) |
- |
633 |
|
Rs. 633 |
21.2 f(Induced over-voltage withstand test
[IS 2026 (Part 3)].) |
- |
1265 |
|
Rs. 1265 |
21.2 g(Separate-source voltage withstand test
[IS 2026 (Part 3)]) |
- |
1265 |
|
Rs. 1265 |
21.3 b(Temperature-rise test [IS 2026 (Part 2)].) |
- |
31625 |
|
For 1 & 3 phase
- UPTO 100 KVA Rs. 15180
- Above 100 KVA - 500 KVA Rs. 18975
- Above 500 KVA - 2500 KVA Rs. 31625
Rs. 31625 CONSIDERING 2500 KVA TRANSFORMER |
21.3 c(Short-circuit withstand test [IS 2026 (Part 5)]
(up to 200 kVA) and) |
- |
75647 |
|
Upto 200 kVA Test
11/22/33 kV charges for 1ph Dynamic 40480/53130/64515 Thermal 6072/7969.5/9677.3 3ph Dynamic 53130/53130/64515 for Thermal 7969.5/7969.5/9677.3 for other tap Dynamic 65780/65780/64515 for Thermal 9867/9867/9677.3 |
21.3 d(Pressure test) |
- |
11000 |
|
UP to 100 KVA 6600
- ABOVE 100 KVA AND UPTO 2500 KVA 11000 |
21.4 a(Determination of sound levels [IS 2026 (Part 10)];) |
- |
5764 |
|
Rs. 5764 |
21.4 b(Short-circuit withstand test [IS 2026 (Part 5)]
(above 200 kVA);) |
- |
472132.5 |
|
Upto 2500 kVA Test
11/22/33 kV charges for 1ph Dynamic 238050/238050/410550 Thermal 35707.5/35707.5/61582.5 3ph Dynamic 238050/238050/410550 for Thermal 35707.5/35707.5/61582.5 for other tap Dynamic 238050/238050/410550for Thermal 35707.5/35707.5/61582 |
21.4 c(No load current at 112.5 percent voltage
(see 6.9.2, 7.9.2, 8.9.2);) |
- |
2024 |
|
For 1 & 3 phase
- up to 2500 KVA Rs. 2024
For subsequent taps (per tap charges)
- up to 2500 KVA Rs. 1012 |
21.4 d(Paint adhesion test — The test is performed as
per ASTM D3359 (Standard Test Methods for
measuring adhesion by tape test).) |
- |
5560 |
|
Rs. 5560 |
21.5(Pressure and Ester Liquid Leakage Test) |
- |
6600 |
|
UP to 100 KVA 3300
- ABOVE 100 KVA AND UPTO 2500 KVA 6600 |
6.9(Permissible Flux Density and Over Fluxing) |
- |
5775 |
|
UP to 500 KVA 5775 |
11(Minimum clearances in air) |
- |
1265 |
|
Rs. 1265 |
14(Mounting Arrangement) |
- |
1012 |
|
Rs. 1012 |
20(Fittings) |
- |
1012 |
|
Rs. 1012 |
7.9(Permissible Flux Density and Overfluxing) |
- |
8250 |
|
UP to 500 KVA 5775
- ABOVE 500 KVA AND UPTO 2500 KVA 8250 |
8.9(Permissible Flux Density and Overfluxing) |
- |
5775 |
|
UP to 500 KVA 5775 |
7.8(Losses and Impedance Values) |
- |
0 |
|
CHARGES INCLUDED IN Measurement of short-circuit impedance
(principal tapping, when applicable) and load
loss at 50 percent and 100 percent load & Measurement of no-load loss and current TESTS |
6.8(Table 3 Losses and Impedance Values) |
- |
0 |
|
CHARGES INCLUDED IN Measurement of short-circuit impedance
(principal tapping, when applicable) and load
loss at 50 percent and 100 percent load & Measurement of no-load loss and current TESTS |
8.8(Losses and Impedance Values) |
- |
0 |
|
CHARGES INCLUDED IN Measurement of short-circuit impedance
(principal tapping, when applicable) and load
loss at 50 percent and 100 percent load & Measurement of no-load loss and current TESTS |
17(Ability of Transformers to withstand external short circuit) |
- |
472132.5 |
|
Upto 2500 kVA Test
11/22/33 kV charges for 1ph Dynamic 238050/238050/410550 Thermal 35707.5/35707.5/61582.5 3ph Dynamic 238050/238050/410550 for Thermal 35707.5/35707.5/61582.5 for other tap Dynamic 238050/238050/410550for Thermal 35707.5/35707.5/61582 |
21.3 a(Lightning impulse test [IS 2026 (Part 3)].) |
- |
57750 |
|
UPTO 2500 KVA 1 PH Rs. 57750, 3PH Rs. 57750 |
21.4 e(BDV and Moisture content of liquid in the
transformer (IS 16081, IS 16099, IS 16899 or
IS 16659, whichever is applicable).) |
- |
1990 |
|
Rs. 1990 |
21.2(Routine Tests) |
- |
60773 |
|
CHARGES FOR ALL ROUTINE TESTS FOR 2500 KVA TRANSFORMER 17 TAPS |
21.3(Types test) |
- |
572507.5 |
|
CHARGES FOR ALL TYPE TESTS FOR 2500 KVA TRANSFORMER 17 TAPS |
21.4(Special Test) |
- |
482564.5 |
|
CHARGES FOR ALL SPECIAL TESTS FOR 2500 KVA TRANSFORMER 17 TAPS |
6.8(Losses and Impedance Value) |
- |
0 |
|
CHARGES INCLUDED IN Measurement of short-circuit impedance
(principal tapping, when applicable) and load
loss at 50 percent and 100 percent load & Measurement of no-load loss and current TESTS |
6.9(Permissible flux density and over fluxing) |
- |
5775 |
|
UP to 500 KVA 5775 |
17(Ability of transformers to whitstand external short circuit) |
- |
472132.5 |
|
Upto 2500 kVA Test
11/22/33 kV charges for 1ph Dynamic 238050/238050/410550 Thermal 35707.5/35707.5/61582.5 3ph Dynamic 238050/238050/410550 for Thermal 35707.5/35707.5/61582.5 for other tap Dynamic 238050/238050/410550for Thermal 35707.5/35707.5/61582 |
11(Minimum clearances in air) |
- |
1265 |
|
Rs. 1265 |
14(Mounting Arrangement) |
- |
1012 |
|
Rs. 1012 |
21.5(Pressure and Ester Liquid Leakage Test) |
- |
6600 |
|
UP to 100 KVA 3300
- ABOVE 100 KVA AND UPTO 2500 KVA 6600 |
21.2 a(Measurement of winding resistance
[IS 2026 (Part 1)].) |
- |
6839 |
|
For 1 & 3 phase
- up to 2500 KVA Rs. 759
For subsequent taps (per tap charges)
- up to 2500 KVA Rs. 380
Rs. 6839 CONSIDERING 2500 KVA TRANSFORMER 17 TAPS |
21.2 b(Measurement of voltage ratio and check of phase
displacement [IS 2026 (Part 1)].) |
- |
9108 |
|
For 1 & 3 phase
- up to 2500 KVA Rs. 1012
For subsequent taps (per tap charges)
- up to 2500 KVA Rs. 506
Rs. 6839 CONSIDERING 2500 KVA TRANSFORMER 17 TAPS |
21.2 c(Measurement of short-circuit impedance
(principal tapping, when applicable) and load
loss at 50 percent and 100 percent load
[IS 2026 (Part 1)].) |
- |
22138 |
|
For 1 & 3 phase
- UPTO 100 KVA Rs. 3036
- Above 100 KVA - 500 KVA Rs. 4744
- Above 500 KVA - 2500 KVA Rs. 9488
For subsequent taps (per tap charges)
- UPTO 100 KVA Rs. 2024
- Above 100 KVA - 500 KVA Rs. 3163
- Above 500 KVA - 2500 KVA Rs. 6325 |
21.2 d(Measurement of no-load loss and current
[IS 2026 (Part 1)].) |
- |
6325 |
|
For 1 & 3 phase
- UPTO 100 KVA Rs. 2024
- Above 100 KVA - 500 KVA Rs. 3163
- Above 500 KVA - 2500 KVA Rs. 6325
For subsequent taps (per tap charges)
- UPTO 100 KVA Rs. 1012
- Above 100 KVA - 500 KVA Rs. 1581
- Above 500 KVA - 2500 KVA Rs. 3163 |
21.2 e(Measurement of insulation resistance
[IS 2026 (Part 1)].) |
- |
633 |
|
Rs. 633 |
21.2 f(Induced over-voltage withstand test
[IS 2026 (Part 3)].) |
- |
1265 |
|
Rs. 1265 |
21.2 g(Separate-source voltage withstand test
[IS 2026 (Part 3)]) |
- |
1265 |
|
Rs. 1265 |
21.3 b(Temperature-rise test [IS 2026 (Part 2)].) |
- |
31625 |
|
For 1 & 3 phase
- UPTO 100 KVA Rs. 15180
- Above 100 KVA - 500 KVA Rs. 18975
- Above 500 KVA - 2500 KVA Rs. 31625
Rs. 31625 CONSIDERING 2500 KVA TRANSFORMER |
21.3 c(Short-circuit withstand test [IS 2026 (Part 5)]
(up to 200 kVA) and) |
- |
75647 |
|
Upto 250 kVA Test
11/22/33 kV charges for 1ph Dynamic 40480/53130/64515 Thermal 6072/7969.5/9677.3 3ph Dynamic 53130/53130/64515 for Thermal 7969.5/7969.5/9677.3 for other tap Dynamic 65780/65780/64515 for Thermal 9867/9867/9677.3 |
21.3 d(Pressure test) |
- |
11000 |
|
UP to 100 KVA 6600
- ABOVE 100 KVA AND UPTO 2500 KVA 11000 |
21.4 a(Determination of sound levels [IS 2026 (Part 10)];) |
- |
5764 |
|
Rs. 5764 |
21.4 b(Short-circuit withstand test [IS 2026 (Part 5)]
(above 200 kVA);) |
- |
472132.5 |
|
Upto 2500 kVA Test
11/22/33 kV charges for 1ph Dynamic 238050/238050/410550 Thermal 35707.5/35707.5/61582.5 3ph Dynamic 238050/238050/410550 for Thermal 35707.5/35707.5/61582.5 for other tap Dynamic 238050/238050/410550for Thermal 35707.5/35707.5/61582 |
21.4 c(No load current at 112.5 percent voltage
(see 6.9.2, 7.9.2, 8.9.2);) |
- |
2024 |
|
For 1 & 3 phase
- up to 2500 KVA Rs. 2024
For subsequent taps (per tap charges)
- up to 2500 KVA Rs. 1012 |
21.4 d(Paint adhesion test — The test is performed as
per ASTM D3359 (Standard Test Methods for
measuring adhesion by tape test).) |
- |
5560 |
|
Rs. 5560 |
21.5(Pressure and Ester Liquid Leakage Test) |
- |
6600 |
|
UP to 100 KVA 3300
- ABOVE 100 KVA AND UPTO 2500 KVA 6600 |
6.9(Permissible Flux Density and Over Fluxing) |
- |
5775 |
|
UP to 500 KVA 5775 |
11(Minimum clearances in air) |
- |
1265 |
|
Rs. 1265 |
14(Mounting Arrangement) |
- |
1012 |
|
Rs. 1012 |
20(Fittings) |
- |
1012 |
|
Rs. 1012 |
7.9(Permissible Flux Density and Overfluxing) |
- |
8250 |
|
UP to 500 KVA 5750
- ABOVE 500 KVA AND UPTO 2500 KVA 8250 |
8.9(Permissible Flux Density and Overfluxing) |
- |
5775 |
|
UP to 500 KVA 5775 |
7.8(Losses and Impedance Values) |
- |
0 |
|
CHARGES INCLUDED IN Measurement of short-circuit impedance
(principal tapping, when applicable) and load
loss at 50 percent and 100 percent load & Measurement of no-load loss and current TESTS |
6.8(Table 3 Losses and Impedance Values) |
- |
0 |
|
CHARGES INCLUDED IN Measurement of short-circuit impedance
(principal tapping, when applicable) and load
loss at 50 percent and 100 percent load & Measurement of no-load loss and current TESTS |
8.8(Losses and Impedance Values) |
- |
0 |
|
CHARGES INCLUDED IN Measurement of short-circuit impedance
(principal tapping, when applicable) and load
loss at 50 percent and 100 percent load & Measurement of no-load loss and current TESTS |
17(Ability of Transformers to withstand external short circuit) |
- |
472132.5 |
|
Upto 2500 kVA Test
11/22/33 kV charges for 1ph Dynamic 238050/238050/410550 Thermal 35707.5/35707.5/61582.5 3ph Dynamic 238050/238050/410550 for Thermal 35707.5/35707.5/61582.5 for other tap Dynamic 238050/238050/410550for Thermal 35707.5/35707.5/61582 |
21.3 a(Lightning impulse test [IS 2026 (Part 3)].) |
- |
57750 |
|
- ABOVE 500 KVA AND UPTO 2500 KVA 1 ph 57750, 3 ph 57750 |
21.4 e(BDV and Moisture content of liquid in the
transformer (IS 16081, IS 16099, IS 16899 or
IS 16659, whichever is applicable).) |
- |
1990 |
|
Rs. 1990 |
21.2(Routine Tests) |
- |
60773 |
|
CHARGES FOR ALL ROUTINE TESTS FOR 2500 KVA TRANSFORMER 17 TAPS |
21.3(Types test) |
- |
572507.5 |
|
CHARGES FOR ALL TYPE TESTS FOR 2500 KVA TRANSFORMER 17 TAPS |
21.4(Special Test) |
- |
482564.5 |
|
CHARGES FOR ALL SPECIAL TESTS FOR 2500 KVA TRANSFORMER 17 TAPS |
6.8(Losses and Impedance Value) |
- |
0 |
|
CHARGES INCLUDED IN Measurement of short-circuit impedance
(principal tapping, when applicable) and load
loss at 50 percent and 100 percent load & Measurement of no-load loss and current TESTS |
6.9(Permissible flux density and over fluxing) |
- |
5775 |
|
UP to 500 KVA 5775 |
17(Ability of transformers to whitstand external short circuit) |
- |
472132.5 |
|
Upto 2500 kVA Test
11/22/33 kV charges for 1ph Dynamic 238050/238050/410550 Thermal 35707.5/35707.5/61582.5 3ph Dynamic 238050/238050/410550 for Thermal 35707.5/35707.5/61582.5 for other tap Dynamic 238050/238050/410550for Thermal 35707.5/35707.5/61582 |
11(Minimum clearances in air) |
- |
1265 |
|
Rs. 1265 |
14(Mounting Arrangement) |
- |
1012 |
|
Rs. 1012 |
21.5(Pressure and Ester Liquid Leakage Test) |
- |
6600 |
|
UP to 100 KVA 3300
- ABOVE 100 KVA AND UPTO 2500 KVA 6600 |
21.2 a(Measurement of winding resistance
[IS 2026 (Part 1)].) |
- |
6839 |
|
For 1 & 3 phase
- up to 2500 KVA Rs. 759
For subsequent taps (per tap charges)
- up to 2500 KVA Rs. 380
Rs. 6839 CONSIDERING 2500 KVA TRANSFORMER 17 TAPS |
21.2 b(Measurement of voltage ratio and check of phase
displacement [IS 2026 (Part 1)].) |
- |
9108 |
|
For 1 & 3 phase
- up to 2500 KVA Rs. 1012
For subsequent taps (per tap charges)
- up to 2500 KVA Rs. 506
Rs. 6839 CONSIDERING 2500 KVA TRANSFORMER 17 TAPS |
21.2 c(Measurement of short-circuit impedance
(principal tapping, when applicable) and load
loss at 50 percent and 100 percent load
[IS 2026 (Part 1)].) |
- |
22138 |
|
For 1 & 3 phase
- UPTO 100 KVA Rs. 3036
- Above 100 KVA - 500 KVA Rs. 4744
- Above 500 KVA - 2500 KVA Rs. 9488
For subsequent taps (per tap charges)
- UPTO 100 KVA Rs. 2024
- Above 100 KVA - 500 KVA Rs. 3163
- Above 500 KVA - 2500 KVA Rs. 6325 |
21.2 d(Measurement of no-load loss and current
[IS 2026 (Part 1)].) |
- |
6325 |
|
For 1 & 3 phase
- UPTO 100 KVA Rs. 2024
- Above 100 KVA - 500 KVA Rs. 3163
- Above 500 KVA - 2500 KVA Rs. 6325
For subsequent taps (per tap charges)
- UPTO 100 KVA Rs. 1012
- Above 100 KVA - 500 KVA Rs. 1581
- Above 500 KVA - 2500 KVA Rs. 3163 |
21.2 e(Measurement of insulation resistance
[IS 2026 (Part 1)].) |
- |
633 |
|
Rs. 633 |
21.2 f(Induced over-voltage withstand test
[IS 2026 (Part 3)].) |
- |
1265 |
|
Rs. 1265 |
21.2 g(Separate-source voltage withstand test
[IS 2026 (Part 3)]) |
- |
1265 |
|
Rs. 1265 |
21.3 b(Temperature-rise test [IS 2026 (Part 2)].) |
- |
31625 |
|
For 1 & 3 phase
- UPTO 100 KVA Rs. 15180
- Above 100 KVA - 500 KVA Rs. 18975
- Above 500 KVA - 2500 KVA Rs. 31625
Rs. 31625 CONSIDERING 2500 KVA TRANSFORMER |
21.3 c(Short-circuit withstand test [IS 2026 (Part 5)]
(up to 200 kVA) and) |
- |
75647 |
|
Upto 200 kVA Test
11/22/33 kV charges for 1ph Dynamic 40480/53130/64515 Thermal 6072/7969.5/9677.3 3ph Dynamic 53130/53130/64515 for Thermal 7969.5/7969.5/9677.3 for other tap Dynamic 65780/65780/64515 for Thermal 9867/9867/9677.3 |
21.3 d(Pressure test) |
- |
11000 |
|
UP to 100 KVA 6600
- ABOVE 100 KVA AND UPTO 2500 KVA 11000 |
21.4 a(Determination of sound levels [IS 2026 (Part 10)];) |
- |
5764 |
|
Rs. 5764 |
21.4 b(Short-circuit withstand test [IS 2026 (Part 5)]
(above 200 kVA);) |
- |
472132.5 |
|
Upto 2500 kVA Test
11/22/33 kV charges for 1ph Dynamic 238050/238050/410550 Thermal 35707.5/35707.5/61582.5 3ph Dynamic 238050/238050/410550 for Thermal 35707.5/35707.5/61582.5 for other tap Dynamic 238050/238050/410550for Thermal 35707.5/35707.5/61582 |
21.4 c(No load current at 112.5 percent voltage
(see 6.9.2, 7.9.2, 8.9.2);) |
- |
2024 |
|
For 1 & 3 phase
- up to 2500 KVA Rs. 2024
For subsequent taps (per tap charges)
- up to 2500 KVA Rs. 1012 |
21.4 d(Paint adhesion test — The test is performed as
per ASTM D3359 (Standard Test Methods for
measuring adhesion by tape test).) |
- |
5560 |
|
Rs. 5560 |
21.5(Pressure and Ester Liquid Leakage Test) |
- |
6600 |
|
UP to 100 KVA 3300
- ABOVE 100 KVA AND UPTO 2500 KVA 6600 |
6.9(Permissible Flux Density and Over Fluxing) |
- |
5775 |
|
UP to 500 KVA 5775 |
11(Minimum clearances in air) |
- |
1265 |
|
Rs. 1265 |
14(Mounting Arrangement) |
- |
1012 |
|
Rs. 1012 |
20(Fittings) |
- |
1012 |
|
Rs. 1012 |
7.9(Permissible Flux Density and Overfluxing) |
- |
8250 |
|
UP to 500 KVA 5750
- ABOVE 500 KVA AND UPTO 2500 KVA 8250 |
8.9(Permissible Flux Density and Overfluxing) |
- |
5775 |
|
UP to 500 KVA 5775 |
7.8(Losses and Impedance Values) |
- |
0 |
|
CHARGES INCLUDED IN Measurement of short-circuit impedance
(principal tapping, when applicable) and load
loss at 50 percent and 100 percent load & Measurement of no-load loss and current TESTS |
6.8(Table 3 Losses and Impedance Values) |
- |
0 |
|
CHARGES INCLUDED IN Measurement of short-circuit impedance
(principal tapping, when applicable) and load
loss at 50 percent and 100 percent load & Measurement of no-load loss and current TESTS |
8.8(Losses and Impedance Values) |
- |
0 |
|
CHARGES INCLUDED IN Measurement of short-circuit impedance
(principal tapping, when applicable) and load
loss at 50 percent and 100 percent load & Measurement of no-load loss and current TESTS |
17(Ability of Transformers to withstand external short circuit) |
- |
472132.5 |
|
Upto 2500 kVA Test
11/22/33 kV charges for 1ph Dynamic 238050/238050/410550 Thermal 35707.5/35707.5/61582.5 3ph Dynamic 238050/238050/410550 for Thermal 35707.5/35707.5/61582.5 for other tap Dynamic 238050/238050/410550for Thermal 35707.5/35707.5/61582 |
21.3 a(Lightning impulse test [IS 2026 (Part 3)].) |
- |
57750 |
|
FOR 2500 KVA 1PH Rs.57750 , 3PH RS.57750 |
21.4 e(BDV and Moisture content of liquid in the
transformer (IS 16081, IS 16099, IS 16899 or
IS 16659, whichever is applicable).) |
- |
1990 |
|
Rs. 1990 |
21.2(Routine Tests) |
- |
60773 |
|
CHARGES FOR ALL ROUTINE TESTS FOR 2500 KVA TRANSFORMER 17 TAP |
21.3(Types test) |
- |
572507.5 |
|
CHARGES FOR ALL TYPE TESTS FOR 2500 KVA TRANSFORMER 17 TAP |
21.4(Special Test) |
- |
482564.5 |
|
CHARGES FOR ALL SPECIAL TESTS FOR 2500 KVA TRANSFORMER 17 TAP |
6.8(Losses and Impedance Value) |
- |
0 |
|
CHARGES INCLUDED IN Measurement of short-circuit impedance
(principal tapping, when applicable) and load
loss at 50 percent and 100 percent load & Measurement of no-load loss and current TESTS |
6.9(Permissible flux density and over fluxing) |
- |
5775 |
|
UP to 500 KVA 5775 |
17(Ability of transformers to whitstand external short circuit) |
- |
472132.5 |
|
Upto 2500 kVA Test
11/22/33 kV charges for 1ph Dynamic 238050/238050/410550 Thermal 35707.5/35707.5/61582.5 3ph Dynamic 238050/238050/410550 for Thermal 35707.5/35707.5/61582.5 for other tap Dynamic 238050/238050/410550for Thermal 35707.5/35707.5/61582 |
11(Minimum clearances in air) |
- |
1265 |
|
Rs. 1265 |
14(Mounting Arrangement) |
- |
1012 |
|
Rs. 1012 |
21.5(Pressure and Ester Liquid Leakage Test) |
- |
6600 |
|
UP to 100 KVA 3300
- ABOVE 100 KVA AND UPTO 2500 KVA 6600 |
16(Conservator for non-sealed typetransformers) |
- |
1012 |
|
Rs. 1012 |
20(Fittings) |
- |
1012 |
|
Rs. 1012 |
16(Conservator for non-sealed type transformers) |
- |
1012 |
|
Rs. 1012 |
|
Complete
|
|
30 Nov, 2025 |
- Included w.e.f. 04.12.2024 |
11 |
Central Power Research Institute (CPRI), Bangalore
| IS 1180 : Part 3 (2021) |
Outdoor/Indoor Type Liquid Immersed Distribution Transformers Up to and Including 2 500 kVA, 33 kV — Specification Part 3 Natural/Synthetic Organic Ester Liquid Immersed |
- |
-
|
302090 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
21.2 a(Measurement of winding resistance
[IS 2026 (Part 1)].) |
- |
5700 |
|
Test charges will vary depending on the rating of the sample. The applicable test charges will be intimated through a proforma invoice. |
21.2 b(Measurement of voltage ratio and check of phase
displacement [IS 2026 (Part 1)].) |
- |
3800 |
|
Test charges will vary depending on the rating of the sample. The applicable test charges will be intimated through a proforma invoice. |
21.2 c(Measurement of short-circuit impedance
(principal tapping, when applicable) and load
loss at 50 percent and 100 percent load
[IS 2026 (Part 1)].) |
- |
10260 |
|
Test charges will vary depending on the rating of the sample. The applicable test charges will be intimated through a proforma invoice. |
21.2 d(Measurement of no-load loss and current
[IS 2026 (Part 1)].) |
- |
1900 |
|
Test charges will vary depending on the rating of the sample. The applicable test charges will be intimated through a proforma invoice. |
21.2 e(Measurement of insulation resistance
[IS 2026 (Part 1)].) |
- |
2850 |
|
Test charges will vary depending on the rating of the sample. The applicable test charges will be intimated through a proforma invoice. |
21.2 f(Induced over-voltage withstand test
[IS 2026 (Part 3)].) |
- |
3530 |
|
Test charges will vary depending on the rating of the sample. The applicable test charges will be intimated through a proforma invoice. |
21.2 g(Separate-source voltage withstand test
[IS 2026 (Part 3)]) |
- |
1900 |
|
Test charges will vary depending on the rating of the sample. The applicable test charges will be intimated through a proforma invoice. |
21.3 a(Lightning impulse test [IS 2026 (Part 3)].) |
- |
64290 |
|
Test charges will vary depending on the rating of the sample. The applicable test charges will be intimated through a proforma invoice. |
21.3 b(Temperature-rise test [IS 2026 (Part 2)].) |
- |
45870 |
|
Test charges will vary depending on the rating of the sample. The applicable test charges will be intimated through a proforma invoice. |
21.3 c(Short-circuit withstand test [IS 2026 (Part 5)]
(up to 200 kVA) and) |
- |
93120 |
|
Test charges will vary depending on the rating of the sample. The applicable test charges will be intimated through a proforma invoice. |
21.4 a(Determination of sound levels [IS 2026 (Part 10)];) |
- |
31760 |
|
Test charges will vary depending on the rating of the sample. The applicable test charges will be intimated through a proforma invoice. |
21.4 b(Short-circuit withstand test [IS 2026 (Part 5)]
(above 200 kVA);) |
- |
123040 |
|
Test charges will vary depending on the rating of the sample. The applicable test charges will be intimated through a proforma invoice. |
21.4 c(No load current at 112.5 percent voltage
(see 6.9.2, 7.9.2, 8.9.2);) |
- |
1900 |
|
Test charges will vary depending on the rating of the sample. The applicable test charges will be intimated through a proforma invoice. |
21.4 d(Paint adhesion test — The test is performed as
per ASTM D3359 (Standard Test Methods for
measuring adhesion by tape test).) |
- |
2650 |
|
Test charges will vary depending on the rating of the sample. The applicable test charges will be intimated through a proforma invoice. |
21.4 e(BDV and Moisture content of liquid in the
transformer (IS 16081, IS 16099, IS 16899 or
IS 16659, whichever is applicable).) |
- |
3310 |
|
Test charges will vary depending on the rating of the sample. The applicable test charges will be intimated through a proforma invoice. |
21.5(Pressure and Ester Liquid Leakage Test) |
- |
12130 |
|
Test charges will vary depending on the rating of the sample. The applicable test charges will be intimated through a proforma invoice. |
21.3 d(Pressure test) |
- |
12130 |
|
Test charges will vary depending on the rating of the sample. The applicable test charges will be intimated through a proforma invoice. |
6.2, 7.2, 8.2(Rated Frequency) |
- |
0 |
|
Test charges will vary depending on the rating of the sample. The applicable test charges will be intimated through a proforma invoice. |
6.3, 7.3(Nominal System Voltage) |
- |
0 |
|
Test charges will vary depending on the rating of the sample. The applicable test charges will be intimated through a proforma invoice. |
6.4(Table 2 Minimum Basic Insulation Level) |
- |
0 |
|
Test charges will vary depending on the rating of the sample. The applicable test charges will be intimated through a proforma invoice. |
6.5, 7.5(No-Load Voltage Ratios) |
- |
0 |
|
Test charges will vary depending on the rating of the sample. The applicable test charges will be intimated through a proforma invoice. |
6.6, 7.6(Winding Connections and Phase Displacement) |
- |
0 |
|
Test charges will vary depending on the rating of the sample. The applicable test charges will be intimated through a proforma invoice. |
6.7(Tapping Range and Tapping Methods) |
- |
0 |
|
Test charges will vary depending on the rating of the sample. The applicable test charges will be intimated through a proforma invoice. |
6.8(Table 3 Losses and Impedance Values) |
- |
0 |
|
Test charges will vary depending on the rating of the sample. The applicable test charges will be intimated through a proforma invoice. |
6.9(Permissible Flux Density and Over Fluxing) |
- |
0 |
|
Test charges will vary depending on the rating of the sample. The applicable test charges will be intimated through a proforma invoice. |
6.10(Limits of Temperature-rise) |
- |
0 |
|
Test charges will vary depending on the rating of the sample. The applicable test charges will be intimated through a proforma invoice. |
7.1(Table 4 Standard Ratings) |
- |
0 |
|
Test charges will vary depending on the rating of the sample. The applicable test charges will be intimated through a proforma invoice. |
7.4(Table 5 Minimum Basic Insulation Level) |
- |
0 |
|
Test charges will vary depending on the rating of the sample. The applicable test charges will be intimated through a proforma invoice. |
7.7(Tapping Ranges and Tapping Methods) |
- |
0 |
|
Test charges will vary depending on the rating of the sample. The applicable test charges will be intimated through a proforma invoice. |
7.8(Losses and Impedance Values) |
- |
0 |
|
Test charges will vary depending on the rating of the sample. The applicable test charges will be intimated through a proforma invoice. |
7.9(Permissible Flux Density and Overfluxing) |
- |
0 |
|
Test charges will vary depending on the rating of the sample. The applicable test charges will be intimated through a proforma invoice. |
7.10(Limits of Temperature Rise) |
- |
0 |
|
Test charges will vary depending on the rating of the sample. The applicable test charges will be intimated through a proforma invoice. |
8.1 Table 7(Standard Ratings) |
- |
0 |
|
Test charges will vary depending on the rating of the sample. The applicable test charges will be intimated through a proforma invoice. |
8.3(Nominal System Voltage) |
- |
0 |
|
Test charges will vary depending on the rating of the sample. The applicable test charges will be intimated through a proforma invoice. |
8.5(No Load Voltage Ratio) |
- |
0 |
|
Test charges will vary depending on the rating of the sample. The applicable test charges will be intimated through a proforma invoice. |
8.6(Number of Phases and Polarity) |
- |
0 |
|
Test charges will vary depending on the rating of the sample. The applicable test charges will be intimated through a proforma invoice. |
8.4(Table 8 Minimum Basic Insulation Level) |
- |
0 |
|
Test charges will vary depending on the rating of the sample. The applicable test charges will be intimated through a proforma invoice. |
8.8(Losses and Impedance Values) |
- |
0 |
|
Test charges will vary depending on the rating of the sample. The applicable test charges will be intimated through a proforma invoice. |
8.9(Permissible Flux Density and Overfluxing) |
- |
0 |
|
Test charges will vary depending on the rating of the sample. The applicable test charges will be intimated through a proforma invoice. |
8.10(Limits of Temperature Rise) |
- |
0 |
|
Test charges will vary depending on the rating of the sample. The applicable test charges will be intimated through a proforma invoice. |
9(Standard Materials) |
- |
0 |
|
Test charges will vary depending on the rating of the sample. The applicable test charges will be intimated through a proforma invoice. |
10(Terminal Arrangement) |
- |
0 |
|
Test charges will vary depending on the rating of the sample. The applicable test charges will be intimated through a proforma invoice. |
11(Minimum clearances in air) |
- |
0 |
|
Test charges will vary depending on the rating of the sample. The applicable test charges will be intimated through a proforma invoice. |
12(Connectors (Applicable for bare bushing terminations only)) |
- |
0 |
|
Test charges will vary depending on the rating of the sample. The applicable test charges will be intimated through a proforma invoice. |
13(Marking) |
- |
0 |
|
Test charges will vary depending on the rating of the sample. The applicable test charges will be intimated through a proforma invoice. |
14(Mounting Arrangement) |
- |
0 |
|
Test charges will vary depending on the rating of the sample. The applicable test charges will be intimated through a proforma invoice. |
15(Transformer Tank) |
- |
0 |
|
Test charges will vary depending on the rating of the sample. The applicable test charges will be intimated through a proforma invoice. |
16(Conservator for non-sealed typetransformers) |
- |
0 |
|
Test charges will vary depending on the rating of the sample. The applicable test charges will be intimated through a proforma invoice. |
17(Ability of Transformers to withstand external short circuit) |
- |
0 |
|
Test charges will vary depending on the rating of the sample. The applicable test charges will be intimated through a proforma invoice. |
18(Efficiency and regulation) |
- |
0 |
|
Test charges will vary depending on the rating of the sample. The applicable test charges will be intimated through a proforma invoice. |
19(Tolerances) |
- |
0 |
|
Test charges will vary depending on the rating of the sample. The applicable test charges will be intimated through a proforma invoice. |
20(Fittings) |
- |
0 |
|
Test charges will vary depending on the rating of the sample. The applicable test charges will be intimated through a proforma invoice. |
4(SERVICE CONDITIONS) |
- |
0 |
|
Test charges will vary depending on the rating of the sample. The applicable test charges will be intimated through a proforma invoice. |
5(General) |
- |
0 |
|
Test charges will vary depending on the rating of the sample. The applicable test charges will be intimated through a proforma invoice. |
6.1(Rating) |
- |
0 |
|
Test charges will vary depending on the rating of the sample. The applicable test charges will be intimated through a proforma invoice. |
6.2(Rated Frequceny) |
- |
0 |
|
Test charges will vary depending on the rating of the sample. The applicable test charges will be intimated through a proforma invoice. |
6.3(Nominal System Voltage) |
- |
0 |
|
Test charges will vary depending on the rating of the sample. The applicable test charges will be intimated through a proforma invoice. |
6.4(Basic Insulation Level) |
- |
0 |
|
Test charges will vary depending on the rating of the sample. The applicable test charges will be intimated through a proforma invoice. |
6.5(No-Load Voltage Ratios) |
- |
0 |
|
Test charges will vary depending on the rating of the sample. The applicable test charges will be intimated through a proforma invoice. |
6.6(Winding connection and phase displacement) |
- |
0 |
|
Test charges will vary depending on the rating of the sample. The applicable test charges will be intimated through a proforma invoice. |
6.7(Tapping range and tapping methods) |
- |
0 |
|
Test charges will vary depending on the rating of the sample. The applicable test charges will be intimated through a proforma invoice. |
6.8(Losses and Impedance Value) |
- |
0 |
|
Test charges will vary depending on the rating of the sample. The applicable test charges will be intimated through a proforma invoice. |
6.9(Permissible flux density and over fluxing) |
- |
0 |
|
Test charges will vary depending on the rating of the sample. The applicable test charges will be intimated through a proforma invoice. |
6.10(Limits of temperature-rise) |
- |
0 |
|
Test charges will vary depending on the rating of the sample. The applicable test charges will be intimated through a proforma invoice. |
7("Technical parameters of three phase distribution
transformers higher ") |
- |
0 |
|
Test charges will vary depending on the rating of the sample. The applicable test charges will be intimated through a proforma invoice. |
8(Technical parameter of single phase distribution transformers) |
- |
0 |
|
Test charges will vary depending on the rating of the sample. The applicable test charges will be intimated through a proforma invoice. |
9(Standard Materials) |
- |
0 |
|
Test charges will vary depending on the rating of the sample. The applicable test charges will be intimated through a proforma invoice. |
10(Terminal Arrangement) |
- |
0 |
|
Test charges will vary depending on the rating of the sample. The applicable test charges will be intimated through a proforma invoice. |
12(Connectors for bare bushing terminations) |
- |
0 |
|
Test charges will vary depending on the rating of the sample. The applicable test charges will be intimated through a proforma invoice. |
13(Marking) |
- |
0 |
|
Test charges will vary depending on the rating of the sample. The applicable test charges will be intimated through a proforma invoice. |
14(Mounting Arrangement) |
- |
0 |
|
Test charges will vary depending on the rating of the sample. The applicable test charges will be intimated through a proforma invoice. |
15(Trasnformer tank) |
- |
0 |
|
Test charges will vary depending on the rating of the sample. The applicable test charges will be intimated through a proforma invoice. |
16(Conservator for non-sealed type transformers) |
- |
0 |
|
Test charges will vary depending on the rating of the sample. The applicable test charges will be intimated through a proforma invoice. |
17(Ability of transformers to whitstand external short circuit) |
- |
0 |
|
Test charges will vary depending on the rating of the sample. The applicable test charges will be intimated through a proforma invoice. |
18(Efficiency and regulations) |
- |
0 |
|
Test charges will vary depending on the rating of the sample. The applicable test charges will be intimated through a proforma invoice. |
19(Tolerances) |
- |
0 |
|
Test charges will vary depending on the rating of the sample. The applicable test charges will be intimated through a proforma invoice. |
20(Fittings) |
- |
0 |
|
Test charges will vary depending on the rating of the sample. The applicable test charges will be intimated through a proforma invoice. |
21.1(General) |
- |
0 |
|
Test charges will vary depending on the rating of the sample. The applicable test charges will be intimated through a proforma invoice. |
21.2(Routine Tests) |
- |
0 |
|
Test charges will vary depending on the rating of the sample. The applicable test charges will be intimated through a proforma invoice. |
21.3(Types test) |
- |
0 |
|
Test charges will vary depending on the rating of the sample. The applicable test charges will be intimated through a proforma invoice. |
21.4(Special Test) |
- |
0 |
|
Test charges will vary depending on the rating of the sample. The applicable test charges will be intimated through a proforma invoice. |
21.5(Pressure and Ester Liquid Leakage Test) |
- |
0 |
|
Test charges will vary depending on the rating of the sample. The applicable test charges will be intimated through a proforma invoice. |
22(Information required with enquiry and order) |
- |
0 |
|
Test charges will vary depending on the rating of the sample. The applicable test charges will be intimated through a proforma invoice. |
6.1 Table 1(Standard Ratings) |
- |
0 |
|
Test charges will vary depending on the rating of the sample. The applicable test charges will be intimated through a proforma invoice. |
11(Minimum clearances in air) |
- |
0 |
|
Test charges will vary depending on the rating of the sample. The applicable test charges will be intimated through a proforma invoice. |
|
Complete
|
|
31 Dec, 2026 |
- Included w.e.f. 13.09.2024 |
12 |
RTRC LIMITED
| IS 1180 : Part 3 (2021) |
Outdoor/Indoor Type Liquid Immersed Distribution Transformers Up to and Including 2 500 kVA, 33 kV — Specification Part 3 Natural/Synthetic Organic Ester Liquid Immersed |
Natural/Synthetic Organic Ester Liquid Immersed |
-
|
132000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
6.1 Table 1(Standard Ratings) |
- |
0 |
|
- |
6.2, 7.2, 8.2(Rated Frequency) |
- |
0 |
|
- |
6.3, 7.3(Nominal System Voltage) |
- |
0 |
|
- |
6.4(Table 2 Minimum Basic Insulation Level) |
- |
0 |
|
- |
6.5, 7.5(No-Load Voltage Ratios) |
- |
0 |
|
- |
6.6, 7.6(Winding Connections and Phase Displacement) |
- |
0 |
|
- |
6.7(Tapping Range and Tapping Methods) |
- |
0 |
|
- |
6.8(Table 3 Losses and Impedance Values) |
- |
0 |
|
- |
6.9(Permissible Flux Density and Over Fluxing) |
- |
0 |
|
- |
6.10(Limits of Temperature-rise) |
- |
0 |
|
- |
7.1(Table 4 Standard Ratings) |
- |
0 |
|
- |
7.4(Table 5 Minimum Basic Insulation Level) |
- |
0 |
|
- |
7.7(Tapping Ranges and Tapping Methods) |
- |
0 |
|
- |
7.8(Losses and Impedance Values) |
- |
0 |
|
- |
7.9(Permissible Flux Density and Overfluxing) |
- |
0 |
|
- |
7.10(Limits of Temperature Rise) |
- |
0 |
|
- |
8.1 Table 7(Standard Ratings) |
- |
0 |
|
- |
8.3(Nominal System Voltage) |
- |
0 |
|
- |
8.5(No Load Voltage Ratio) |
- |
0 |
|
- |
8.6(Number of Phases and Polarity) |
- |
0 |
|
- |
8.4(Table 8 Minimum Basic Insulation Level) |
- |
0 |
|
- |
8.8(Losses and Impedance Values) |
- |
0 |
|
- |
8.9(Permissible Flux Density and Overfluxing) |
- |
0 |
|
- |
8.10(Limits of Temperature Rise) |
- |
0 |
|
- |
9(Standard Materials) |
- |
0 |
|
- |
10(Terminal Arrangement) |
- |
0 |
|
- |
11(Minimum clearances in air) |
- |
0 |
|
- |
12(Connectors (Applicable for bare bushing terminations only)) |
- |
0 |
|
- |
13(Marking) |
- |
0 |
|
- |
14(Mounting Arrangement) |
- |
0 |
|
- |
15(Transformer Tank) |
- |
0 |
|
- |
16(Conservator for non-sealed typetransformers) |
- |
0 |
|
- |
18(Efficiency and regulation) |
- |
0 |
|
- |
19(Tolerances) |
- |
0 |
|
- |
20(Fittings) |
- |
0 |
|
- |
21.2 a(Measurement of winding resistance
[IS 2026 (Part 1)].) |
- |
7000 |
|
Complete testing charges Rs. 88000/- for 0 to 100 kVA, Rs. 98100/- for 100kVA to 250kVA, Rs. 104000/- for 250kVA
to 630 kVA, Rs. 105100/- for 630kVA to 1000kVA, Rs. 129900/- for 1000kVA to1600kVA, Rs. 132000/- for 1600kVA to 2500kVA |
21.2 b(Measurement of voltage ratio and check of phase
displacement [IS 2026 (Part 1)].) |
- |
5500 |
|
- |
21.2 c(Measurement of short-circuit impedance
(principal tapping, when applicable) and load
loss at 50 percent and 100 percent load
[IS 2026 (Part 1)].) |
- |
5500 |
|
- |
21.2 d(Measurement of no-load loss and current
[IS 2026 (Part 1)].) |
- |
3500 |
|
- |
21.2 e(Measurement of insulation resistance
[IS 2026 (Part 1)].) |
- |
2500 |
|
- |
21.2 f(Induced over-voltage withstand test
[IS 2026 (Part 3)].) |
- |
4500 |
|
- |
21.2 g(Separate-source voltage withstand test
[IS 2026 (Part 3)]) |
- |
4000 |
|
- |
21.3 a(Lightning impulse test [IS 2026 (Part 3)].) |
- |
41000 |
|
- |
21.3 b(Temperature-rise test [IS 2026 (Part 2)].) |
- |
24000 |
|
- |
21.3 d(Pressure test) |
- |
6000 |
|
- |
21.4 a(Determination of sound levels [IS 2026 (Part 10)];) |
- |
8000 |
|
- |
21.4 c(No load current at 112.5 percent voltage
(see 6.9.2, 7.9.2, 8.9.2);) |
- |
1000 |
|
- |
21.4 d(Paint adhesion test — The test is performed as
per ASTM D3359 (Standard Test Methods for
measuring adhesion by tape test).) |
- |
3000 |
|
- |
21.4 e(BDV and Moisture content of liquid in the
transformer (IS 16081, IS 16099, IS 16899 or
IS 16659, whichever is applicable).) |
- |
2000 |
|
- |
21.5(Pressure and Ester Liquid Leakage Test) |
- |
8000 |
|
- |
4(SERVICE CONDITIONS) |
- |
0 |
|
- |
5(General) |
- |
0 |
|
- |
6.1(Rating) |
- |
0 |
|
- |
6.2(Rated Frequceny) |
- |
0 |
|
- |
6.3(Nominal System Voltage) |
- |
0 |
|
- |
6.4(Basic Insulation Level) |
- |
0 |
|
- |
6.5(No-Load Voltage Ratios) |
- |
0 |
|
- |
6.6(Winding connection and phase displacement) |
- |
0 |
|
- |
6.7(Tapping range and tapping methods) |
- |
0 |
|
- |
6.8(Losses and Impedance Value) |
- |
0 |
|
- |
6.9(Permissible flux density and over fluxing) |
- |
0 |
|
- |
6.10(Limits of temperature-rise) |
- |
0 |
|
- |
7("Technical parameters of three phase distribution
transformers higher ") |
- |
0 |
|
- |
8(Technical parameter of single phase distribution transformers) |
- |
0 |
|
- |
9(Standard Materials) |
- |
0 |
|
- |
10(Terminal Arrangement) |
- |
0 |
|
- |
11(Minimum clearances in air) |
- |
0 |
|
- |
12(Connectors for bare bushing terminations) |
- |
0 |
|
- |
13(Marking) |
- |
0 |
|
- |
14(Mounting Arrangement) |
- |
0 |
|
- |
15(Trasnformer tank) |
- |
0 |
|
- |
16(Conservator for non-sealed type transformers) |
- |
0 |
|
- |
18(Efficiency and regulations) |
- |
0 |
|
- |
19(Tolerances) |
- |
0 |
|
- |
20(Fittings) |
- |
0 |
|
- |
21.1(General) |
- |
0 |
|
- |
21.2(Routine Tests) |
- |
40500 |
|
Routine testing charges Rs. 22600/- for 0 to 100 kVA, Rs. 25700/- for 100kVA to 250kVA, Rs. 28200/- for 250kVA
to 630 kVA, Rs. 29100/- for 630kVA to 1000kVA, Rs. 36600/- for 1000kVA to1600kVA, Rs. 40500/- for 1600kVA to 2500kVA |
21.3(Types test) |
- |
132000 |
|
- |
21.4(Special Test) |
- |
14000 |
|
Additional charges if applicable |
21.5(Pressure and Ester Liquid Leakage Test) |
- |
0 |
|
- |
22(Information required with enquiry and order) |
- |
0 |
|
- |
6.1 Table 1(Standard Ratings) |
- |
0 |
|
- |
6.2, 7.2, 8.2(Rated Frequency) |
- |
0 |
|
- |
6.3, 7.3(Nominal System Voltage) |
- |
0 |
|
- |
6.4(Table 2 Minimum Basic Insulation Level) |
- |
0 |
|
- |
6.5, 7.5(No-Load Voltage Ratios) |
- |
0 |
|
- |
6.6, 7.6(Winding Connections and Phase Displacement) |
- |
0 |
|
- |
6.7(Tapping Range and Tapping Methods) |
- |
0 |
|
- |
6.8(Table 3 Losses and Impedance Values) |
- |
0 |
|
- |
6.9(Permissible Flux Density and Over Fluxing) |
- |
0 |
|
- |
6.10(Limits of Temperature-rise) |
- |
0 |
|
- |
7.1(Table 4 Standard Ratings) |
- |
0 |
|
- |
7.4(Table 5 Minimum Basic Insulation Level) |
- |
0 |
|
- |
7.7(Tapping Ranges and Tapping Methods) |
- |
0 |
|
- |
7.8(Losses and Impedance Values) |
- |
0 |
|
- |
7.9(Permissible Flux Density and Overfluxing) |
- |
0 |
|
- |
7.10(Limits of Temperature Rise) |
- |
0 |
|
- |
8.1 Table 7(Standard Ratings) |
- |
0 |
|
- |
8.3(Nominal System Voltage) |
- |
0 |
|
- |
8.5(No Load Voltage Ratio) |
- |
0 |
|
- |
8.6(Number of Phases and Polarity) |
- |
0 |
|
- |
8.4(Table 8 Minimum Basic Insulation Level) |
- |
0 |
|
- |
8.8(Losses and Impedance Values) |
- |
0 |
|
- |
8.9(Permissible Flux Density and Overfluxing) |
- |
0 |
|
- |
8.10(Limits of Temperature Rise) |
- |
0 |
|
- |
9(Standard Materials) |
- |
0 |
|
- |
10(Terminal Arrangement) |
- |
0 |
|
- |
11(Minimum clearances in air) |
- |
0 |
|
- |
12(Connectors (Applicable for bare bushing terminations only)) |
- |
0 |
|
- |
13(Marking) |
- |
0 |
|
- |
14(Mounting Arrangement) |
- |
0 |
|
- |
15(Transformer Tank) |
- |
0 |
|
- |
16(Conservator for non-sealed typetransformers) |
- |
0 |
|
- |
18(Efficiency and regulation) |
- |
0 |
|
- |
19(Tolerances) |
- |
0 |
|
- |
20(Fittings) |
- |
0 |
|
- |
21.2 a(Measurement of winding resistance
[IS 2026 (Part 1)].) |
- |
7000 |
|
Complete testing charges Rs. 88000/- for 0 to 100 kVA, Rs. 98100/- for 100kVA to 250kVA, Rs. 104000/- for 250kVA
to 630 kVA, Rs. 105100/- for 630kVA to 1000kVA, Rs. 129900/- for 1000kVA to1600kVA, Rs. 132000/- for 1600kVA to 2500kVA |
21.2 b(Measurement of voltage ratio and check of phase
displacement [IS 2026 (Part 1)].) |
- |
5500 |
|
- |
21.2 c(Measurement of short-circuit impedance
(principal tapping, when applicable) and load
loss at 50 percent and 100 percent load
[IS 2026 (Part 1)].) |
- |
5500 |
|
- |
21.2 d(Measurement of no-load loss and current
[IS 2026 (Part 1)].) |
- |
3500 |
|
- |
21.2 e(Measurement of insulation resistance
[IS 2026 (Part 1)].) |
- |
2500 |
|
- |
21.2 f(Induced over-voltage withstand test
[IS 2026 (Part 3)].) |
- |
4500 |
|
- |
21.2 g(Separate-source voltage withstand test
[IS 2026 (Part 3)]) |
- |
4000 |
|
- |
21.3 a(Lightning impulse test [IS 2026 (Part 3)].) |
- |
41000 |
|
- |
21.3 b(Temperature-rise test [IS 2026 (Part 2)].) |
- |
24000 |
|
- |
21.3 d(Pressure test) |
- |
6000 |
|
- |
21.4 a(Determination of sound levels [IS 2026 (Part 10)];) |
- |
8000 |
|
- |
21.4 c(No load current at 112.5 percent voltage
(see 6.9.2, 7.9.2, 8.9.2);) |
- |
1000 |
|
- |
21.4 d(Paint adhesion test — The test is performed as
per ASTM D3359 (Standard Test Methods for
measuring adhesion by tape test).) |
- |
3000 |
|
- |
21.4 e(BDV and Moisture content of liquid in the
transformer (IS 16081, IS 16099, IS 16899 or
IS 16659, whichever is applicable).) |
- |
2000 |
|
- |
21.5(Pressure and Ester Liquid Leakage Test) |
- |
0 |
|
- |
4(SERVICE CONDITIONS) |
- |
0 |
|
- |
5(General) |
- |
0 |
|
- |
6.1(Rating) |
- |
0 |
|
- |
6.2(Rated Frequceny) |
- |
0 |
|
- |
6.3(Nominal System Voltage) |
- |
0 |
|
- |
6.4(Basic Insulation Level) |
- |
0 |
|
- |
6.5(No-Load Voltage Ratios) |
- |
0 |
|
- |
6.6(Winding connection and phase displacement) |
- |
0 |
|
- |
6.7(Tapping range and tapping methods) |
- |
0 |
|
- |
6.8(Losses and Impedance Value) |
- |
0 |
|
- |
6.9(Permissible flux density and over fluxing) |
- |
0 |
|
- |
6.10(Limits of temperature-rise) |
- |
0 |
|
- |
7("Technical parameters of three phase distribution
transformers higher ") |
- |
0 |
|
- |
8(Technical parameter of single phase distribution transformers) |
- |
0 |
|
- |
9(Standard Materials) |
- |
0 |
|
- |
10(Terminal Arrangement) |
- |
0 |
|
- |
11(Minimum clearances in air) |
- |
0 |
|
- |
12(Connectors for bare bushing terminations) |
- |
0 |
|
- |
13(Marking) |
- |
0 |
|
- |
14(Mounting Arrangement) |
- |
0 |
|
- |
15(Trasnformer tank) |
- |
0 |
|
- |
16(Conservator for non-sealed type transformers) |
- |
0 |
|
- |
18(Efficiency and regulations) |
- |
0 |
|
- |
19(Tolerances) |
- |
0 |
|
- |
20(Fittings) |
- |
0 |
|
- |
21.1(General) |
- |
0 |
|
- |
21.2(Routine Tests) |
- |
40500 |
|
Routine testing charges Rs. 22600/- for 0 to 100 kVA, Rs. 25700/- for 100kVA to 250kVA, Rs. 28200/- for 250kVA
to 630 kVA, Rs. 29100/- for 630kVA to 1000kVA, Rs. 36600/- for 1000kVA to1600kVA, Rs. 40500/- for 1600kVA to 2500kVA |
21.3(Types test) |
- |
132000 |
|
- |
21.4(Special Test) |
- |
14000 |
|
Additional charges if applicable |
21.5(Pressure and Ester Liquid Leakage Test) |
- |
0 |
|
- |
22(Information required with enquiry and order) |
- |
0 |
|
- |
|
Complete
|
|
03 Apr, 2027 |
- Included w.e.f 03.05.2024
Exclusion: Cl.17 (Ability of Transformers to withstand external short circuit), Cl. 21.3 c (Short-circuit withstand test [IS 2026 (Part 5)] (up to 200 kVA) and), Cl. 21.4 b (Short-circuit withstand test [IS 2026 (Part 5)] (above 200 kVA);) |
13 |
Electrical Research and Testing Organisation
| IS 1180 : Part 1 (2014) |
Outdoor Type Oil Immersed Distribution Transformers Upto and Including 2 500 kVA, 33kV - Specification Part 1 Mineral Oil Immersed (Fourth Revision) |
1 KVA TO 2500 KVA |
-
|
199450 View breakup
Up to 200 kVA (For single phase and Three phase)
10 kVA for routine test - Rs.11,950/-, for type test - Rs.99,200/-(including Short circuit test), for special test - Rs.7,000/-, For complete testing with short circuit – Rs.1,18,150/-;
16 kVA for routine test - Rs.12,350/-, for type test - Rs.1,00,200/-(including Short circuit test), for special test - Rs.7,000/-, For complete testing with short circuit – Rs.1,19,550/-;
25 kVA for routine test - Rs.12,850/-, for type test - Rs.1,01,200/-(including Short circuit test), for special test - Rs.7,000/-, For complete testing with short circuit – Rs.1,21,050/-;
63 kVA for routine test - Rs.13,850/-, for type test - Rs.1,06,700/-(including Short circuit test), for special test - Rs.7,000/-, For complete testing with short circuit – Rs.1,27,550/-;
100 kVA for routine test - Rs.14,850/-, for type test - Rs.1,08,700/-(including Short circuit test), for special test - Rs.7,000/-, For complete testing with short circuit – Rs.1,30,550/-;
160 kVA (without tap) for routine test - Rs.15,850/-, for type test - Rs.1,27,500/-(including Short circuit test), for special test - Rs.7,000/-, For complete testing with short circuit – Rs.1,50,350/-;
160 kVA (Up to 4 tap) for routine test - Rs.18,700/-, for type test - Rs. 1,27,500/-(including Short circuit test), for special test - Rs.7,000/-, For complete testing with short circuit – Rs.1,53,200/-;
160 kVA (Up to 7 tap) for routine test - Rs.21,550/-, for type test - Rs. 1,27,500/-(including Short circuit test), for special test - Rs.7,000/-, For complete testing with short circuit – Rs.1,56,050/-;
160 kVA (Up to 9 tap) for routine test - Rs.23,450/-, for type test - Rs. 1,27,500/-(including Short circuit test), for special test - Rs.7,000/-, For complete testing with short circuit – Rs.1,56,950/-;
200 kVA (without tap) for routine test - Rs.16,350/-, for type test - Rs.1,35,200/-(including Short circuit test), for special test - Rs.7,000/-, For complete testing with short circuit – Rs.1,57,000/-;
200 kVA (Up to 4 tap) for routine test - Rs.19,200/-, for type test - Rs.1,35,200/-(including Short circuit test), for special test - Rs.7,000/-, For complete testing with short circuit – Rs. 1,57,000/-;
200 kVA (Up to 7 tap) for routine test - Rs.22,050/-, for type test - Rs.1,35,200/-(including Short circuit test), for special test - Rs.7,000/-, For complete testing with short circuit – Rs. 1,57,000/-;
200 kVA (Up to 9 tap) for routine test - Rs.23,950/-, for type test - Rs.1,35,200/-(including Short circuit test), for special test - Rs.7,000/-, For complete testing with short circuit – Rs. 1,57,000/-;
Above 200 kVA up to 2500 kVA (Three phase transformer)
250 kVA (Without tap) for routine test - Rs.16,850/-, for type test - Rs.50,000/-, for special test - Rs.7,000/-(Excluding Short circuit test), For complete testing without short circuit – Rs.73,850/-;
250 kVA (Up to 4 Tap) for routine test - Rs.19,700/-, for type test - Rs.50,000/-, for special test - Rs.7,000/-(Excluding Short circuit test), For complete testing without short circuit – Rs.76,700/-;
250 kVA (Up to 7 Tap) for routine test - Rs.22,550/-, for type test - Rs.50,000/-, for special test - Rs.7,000/-(Excluding Short circuit test), For complete testing without short circuit – Rs.79,550/-;
250 kVA (Up to 9 Tap) for routine test - Rs.24,450/-, for type test - Rs.50,000/-, for special test - Rs.7,000/-(Excluding Short circuit test), For complete testing without short circuit – Rs.81,450/-;
250 kVA (Up to 17 Tap) for routine test - Rs.32,050/-, for type test - Rs.50,000/-, for special test - Rs.7,000/-(Excluding Short circuit test), For complete testing without short circuit – Rs.89,050/-;
315 kVA (Without tap) for routine test - Rs.17,600/-, for type test - Rs.54,000/-, for special test - Rs.7,000/-(Excluding Short circuit test), For complete testing without short circuit – Rs.78,600/-;
315 kVA (Up to 4 tap) for routine test - Rs.20,450/-, for type test - Rs.54,000/-, for special test - Rs.7,000/-(Excluding Short circuit test), For complete testing without short circuit – Rs.81,450/-;
315 kVA (UP to 7 tap) for routine test - Rs.23,300/-, for type test - Rs.54,000/-, for special test - Rs.7,000/-(Excluding Short circuit test), For complete testing without short circuit – Rs.84,300/-;
315 kVA (Up to 9 tap) for routine test - Rs.25,200/-, for type test - Rs.54,000/-, for special test - Rs.7,000/-(Excluding Short circuit test), For complete testing without short circuit – Rs.86,200/-;
315 kVA (Up to 17 tap) for routine test - Rs.32,800/-, for type test - Rs.54,000/-, for special test - Rs.7,000/-(Excluding Short circuit test), For complete testing without short circuit – Rs.93,800/-;
400 kVA (Without tap) for routine test - Rs.17,600/-, for type test - Rs.54,000/-, for special test - Rs.7,000/-(Excluding Short circuit test), For complete testing without short circuit – Rs.78,600/-;
400 kVA (Up to 4 tap) for routine test - Rs.20,450/-, for type test - Rs.54,000/-, for special test - Rs.7,000/-(Excluding Short circuit test), For complete testing without short circuit – Rs.81,450/-;
400 kVA (UP to 7 tap) for routine test - Rs.23,300/-, for type test - Rs.54,000/-, for special test - Rs.7,000/-(Excluding Short circuit test), For complete testing without short circuit – Rs.84,300/-;
400 kVA (Up to 9 tap) for routine test - Rs.25,200/-, for type test - Rs.54,000/-, for special test - Rs.7,000/-(Excluding Short circuit test), For complete testing without short circuit – Rs.86,200/-;
400 kVA (Up to 17 tap) for routine test - Rs.32,800/-, for type test - Rs.54,000/-, for special test - Rs.7,000/-(Excluding Short circuit test), For complete testing without short circuit – Rs.93,800/-;
500 kVA (Without tap) for routine test - Rs.18,600/-, for type test - Rs.54,000/-, for special test - Rs.7,000/-(Excluding Short circuit test), For complete testing without short circuit – Rs.79,600/-;
500 kVA (Up to 4 tap) for routine test - Rs.21,450/-, for type test - Rs.54,000/-, for special test - Rs.7,000/-(Excluding Short circuit test), For complete testing without short circuit – Rs.82,450/-;
500 kVA (Up to 7 tap) for routine test - Rs.24,300/-, for type test - Rs.54,000/-, for special test - Rs.7,000/-(Excluding Short circuit test), For complete testing without short circuit – Rs.85,300/-;
500 kVA (Up to 9 tap) for routine test - Rs.26,200/-, for type test - Rs.54,000/-, for special test - Rs.7,000/-(Excluding Short circuit test), For complete testing without short circuit – Rs.87,200/-;
500 kVA (Up to 17 tap) for routine test - Rs.33,800/-, for type test - Rs.54,000/-, for special test - Rs.7,000/-(Excluding Short circuit test), For complete testing without short circuit – Rs.94,800/-;
630 kVA (Without tap) for routine test - Rs.19,400/-, for type test - Rs.67,000/-, for special test - Rs.7,000/-(Excluding Short circuit test), For complete testing without short circuit – Rs.93,400/-;
630 kVA (Up to 4 tap) for routine test - Rs.22,250/-, for type test - Rs.67,000/-, for special test - Rs.7,000/-(Excluding Short circuit test), For complete testing without short circuit – Rs.92,250/-;
630 kVA (Up to 7 tap) for routine test - Rs.25,100/-, for type test - Rs.67,000/-, for special test - Rs.7,000/-(Excluding Short circuit test), For complete testing without short circuit – Rs.99,100/-;
630 kVA (Up to 9 tap) for routine test - Rs.27,000/-, for type test - Rs.67,000/-, for special test - Rs.7,000/-(Excluding Short circuit test), For complete testing without short circuit – Rs.1,01,000/-;
630 kVA (Up to 17 tap) for routine test - Rs.34,600/-, for type test - Rs.67,000/-, for special test - Rs.7,000/-(Excluding Short circuit test), For complete testing without short circuit – Rs.1,08,600/-;
750 kVA (Without tap) for routine test - Rs.20,700/-, for type test - Rs.67,000/-, for special test - Rs.7,000/-(Excluding Short circuit test), For complete testing without short circuit – Rs.94,700/-;
750 kVA (Up to 4 tap) for routine test - Rs.23,550/-, for type test - Rs.67,000/-, for special test - Rs.7,000/-(Excluding Short circuit test), For complete testing without short circuit – Rs.97,550/-;
750 kVA (Up to 7 tap) for routine test - Rs.26,400/-, for type test - Rs.67,000/-, for special test - Rs.7,000/-(Excluding Short circuit test), For complete testing without short circuit – Rs.1,00,400/-;
750 kVA (Up to 9 tap) for routine test - Rs.28,300/-, for type test - Rs.67,000/-, for special test - Rs.7,000/-(Excluding Short circuit test), For complete testing without short circuit – Rs.1,02,300/-;
750 kVA (Up to 17 tap) for routine test - Rs.35,900/-, for type test - Rs.67,000/-, for special test - Rs.7,000/-(Excluding Short circuit test), For complete testing without short circuit – Rs.1,09,900/-;
751 to 1000 kVA (Without tap) for routine test - Rs.21,800/-, for type test - Rs.67,000/-, for special test - Rs.7,000/-(Excluding Short circuit test), For complete testing without short circuit – Rs.95,800/-;
751 to 1000 kVA (Up to 4 tap) for routine test - Rs.24,650/-, for type test - Rs.67,000/-, for special test - Rs.7,000/-(Excluding Short circuit test), For complete testing without short circuit – Rs.98,650/-;
751 to 1000 kVA (Up to 7 tap) for routine test - Rs.27,500/-, for type test - Rs.67,000/-, for special test - Rs.7,000/-(Excluding Short circuit test), For complete testing without short circuit – Rs.1,01,500/-;
751 to 1000 kVA (Up to 9 tap) for routine test - Rs.29,400/-, for type test - Rs.67,000/-, for special test - Rs.7,000/-(Excluding Short circuit test), For complete testing without short circuit – Rs.1,03,400/-;
751 to 1000 kVA (Up to 17 tap) for routine test - Rs.37,000/-, for type test - Rs.67,000/-, for special test - Rs.7,000/-(Excluding Short circuit test), For complete testing without short circuit – Rs.1,11,000/-;
1250 kVA (Without tap) for routine test - Rs.23,200/-, for type test - Rs.79,000/-, for special test - Rs.7,000/-(Excluding Short circuit test), For complete testing without short circuit – Rs.1,09,200/-;
1250 kVA (Up to 4 tap) for routine test - Rs.26,050/-, for type test - Rs.79,000/-, for special test - Rs.7,000/-(Excluding Short circuit test), For complete testing without short circuit – Rs.1,12,050/-;
1250 kVA (Up to 7 tap) for routine test - Rs.28,900/-, for type test - Rs.79,000/-, for special test - Rs.7,000/-(Excluding Short circuit test), For complete testing without short circuit – Rs.1,14,900/-;
1250 kVA (Up to 9 tap) for routine test - Rs.30,800/-, for type test - Rs.79,000/-, for special test - Rs.7,000/-(Excluding Short circuit test), For complete testing without short circuit – Rs.1,16,800/-;
1250 kVA (Up to 17 tap) for routine test - Rs.38,400/-, for type test - Rs.79,000/-, for special test - Rs.7,000/-(Excluding Short circuit test), For complete testing without short circuit – Rs.1,24,400/-;
1600 kVA (Without tap) for routine test - Rs.23,550/-, for type test - Rs.79,000/-, for special test - Rs.7,000/-(Excluding Short circuit test), For complete testing without short circuit – Rs.1,09,550/-;
1600 kVA (Up to 4 tap) for routine test - Rs.26,900/-, for type test - Rs.79,000/-, for special test - Rs.7,000/-(Excluding Short circuit test), For complete testing without short circuit – Rs.1,12,900/-;
1600 kVA (Up to 7 tap) for routine test - Rs.29,750/-, for type test - Rs.79,000/-, for special test - Rs.7,000/-(Excluding Short circuit test), For complete testing without short circuit – Rs.1,15,750/-;
1600 kVA (Up to 9 tap) for routine test - Rs.31,650/-, for type test - Rs.79,000/-, for special test - Rs.7,000/-(Excluding Short circuit test), For complete testing without short circuit – Rs.1,17,650/-;
1600 kVA (Up to 17 tap) for routine test - Rs.39,250/-, for type test - Rs.79,000/-, for special test - Rs.7,000/-(Excluding Short circuit test), For complete testing without short circuit – Rs.1,25,250/-;
2000 kVA (Without tap) for routine test - Rs.24,200/-, for type test - Rs.79,000/-, for special test - Rs.7,000/-(Excluding Short circuit test), For complete testing without short circuit – Rs.1,10,200/-;
2000 kVA (Up to 4 tap) for routine test - Rs.27,550/-, for type test - Rs.79,000/-, for special test - Rs.7,000/-(Excluding Short circuit test), For complete testing without short circuit – Rs.1,13,550/-;
2000 kVA (Up to 7 tap) for routine test - Rs.30,400/-, for type test - Rs.79,000/-, for special test - Rs.7,000/-(Excluding Short circuit test), For complete testing without short circuit – Rs.1,16,400/-;
2000 kVA (Up to 9 tap) for routine test - Rs.32,300/-, for type test - Rs.79,000/-, for special test - Rs.7,000/-(Excluding Short circuit test), For complete testing without short circuit – Rs.1,18,300/-;
2000 kVA (Up to 17 tap) for routine test - Rs.39,900/-, for type test - Rs.79,000/-, for special test - Rs.7,000/-(Excluding Short circuit test), For complete testing without short circuit – Rs.1,25,900/-;
2500 kVA (Without tap) for routine test - Rs.24,550/-, for type test - Rs.79,000/-, for special test - Rs.7,000/-(Excluding Short circuit test), For complete testing without short circuit – Rs.1,10,550/-;
2500 kVA (Up to 4 tap) for routine test - Rs.27,900/-, for type test - Rs.79,000/-, for special test - Rs.7,000/-(Excluding Short circuit test), For complete testing without short circuit – Rs.1,13,900/-;
2500 kVA (Up to 7 tap) for routine test - Rs.30,750/-, for type test - Rs.79,000/-, for special test - Rs.7,000/-(Excluding Short circuit test), For complete testing without short circuit – Rs.1,16,750/-;
2500 kVA (Up to 9 tap) for routine test - Rs.32,650/-, for type test - Rs.79,000/-, for special test - Rs.7,000/-(Excluding Short circuit test), For complete testing without short circuit – Rs.1,18,650/-;
2500 kVA (Up to 17 tap) for routine test - Rs.40,250/-, for type test - Rs.79,000/-, for special test - Rs.7,000/-(Excluding Short circuit test), For complete testing without short circuit – Rs.1,26,250/-;
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
21.2 a)(Measurement of winding resistance ) |
- |
7050 |
|
Test charges consider for 2500 kVA, 17 tap transformer |
21.2 b)( Measurement of voltage ratio and check of
phase displacemen) |
- |
9650 |
|
Test charges consider for 2500 kVA, 17 tap transformer |
21.2 c)( Measurement of short-circuit impedance
(principal tapping, when applicable) and load
loss at 50 percent and 100 percent load) |
- |
7000 |
|
Test charges consider for 2500 kVA, 17 tap transformer |
21.2 d)(Measurement of no-load loss and current) |
- |
4500 |
|
Test charges consider for 2500 kVA, 17 tap transformer |
21.2 e)(Measurement of insulation resistance) |
- |
550 |
|
Test charges consider for 2500 kVA, 17 tap transformer |
21.2 f)(Induced over-voltage withstand test) |
- |
1000 |
|
Test charges consider for 2500 kVA, 17 tap transformer |
21.2 g)( Separate-source voltage withstand test) |
- |
1000 |
|
Test charges consider for 2500 kVA, 17 tap transformer |
21.5.2.2(routine test :For Transformers Above 200 kVA and Up to Including 2 500 kVA) |
- |
5000 |
|
Test charges consider for 2500 kVA, 17 tap transformer |
21.5.2.3( Oil leakage test (routine test)) |
- |
4500 |
|
Test charges consider for 2500 kVA, 17 tap transformer |
21.3(a )(Lightning impulse test) |
- |
65000 |
|
Test charges consider for 2500 kVA, 17 tap transformer |
21.3(b)(Temperature-rise test) |
- |
20000 |
|
Test charges consider for 2500 kVA, 17 tap transformer |
21.5.2.1(Type test : For Transformers Above 200 kVA and Up to Including 2 500 kVA) |
- |
9000 |
|
Test charges consider for 2500 kVA, 17 tap transformer |
21.4 a)( Determination of sound levels) |
- |
2500 |
|
Test charges consider for 2500 kVA, 17 tap transformer |
21.4 c(No load current at 112.5 percent voltage.) |
- |
1500 |
|
- |
21.4 d(Paint adhesion tests) |
- |
1000 |
|
- |
21.4 e(BDV and moisture content of oil in the transformer) |
- |
7000 |
|
- |
11(Minimum clearance in Air) |
- |
1000 |
|
- |
14.2(MOUNTING ARRANGEMENT) |
- |
1000 |
|
- |
16(Conservator for Non-sealed type Transformers) |
- |
1000 |
|
- |
20(Fittings) |
- |
1000 |
|
- |
21.3(c)(Short-circuit withstand test) |
- |
62700 |
|
Test charges consider for 40 kVA, |
21.5.1.1(Pressure test-Type test (For Transformers up to 200 kVA
)) |
- |
9000 |
|
- |
21.5.1.2(Pressure test-routine test (For Transformers up to 200 kVA
)) |
- |
5000 |
|
- |
21.5.1.3(Oil leakage test upto 200 KVA) |
- |
4000 |
|
- |
21.5.3.1(For Single Phase Distribution Transformers Up to Including 25 kVA : pressure test (type test)) |
- |
9000 |
|
- |
21.5.3.2(For Single Phase Distribution Transformers Up to Including 25 kVA : pressure test (routine test)) |
- |
5000 |
|
- |
21.5.3.3(Oil leakage test (routine test)) |
- |
4500 |
|
- |
|
Complete
|
|
10 Jun, 2027 |
- (i) Complete test facility up to 200 kVA.
(ii) For rating greater than 200 kVA: Complete excluding Short circuit test as per Cl.21.4(b) Short circuit withstand test (above 200 kVA) |
14 |
C and I Calibrations Pvt. Ltd.
| IS 1180 : Part 1 (2014) |
Outdoor Type Oil Immersed Distribution Transformers Upto and Including 2 500 kVA, 33kV - Specification Part 1 Mineral Oil Immersed (Fourth Revision) |
Upto and Including 2 500 kVA |
-
|
218500 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
21.2 a)(Measurement of winding resistance ) |
- |
3000 |
|
Charges are mentioned for 33kV, 2500 kVA, 3 Phase Distribution Transformer. |
21.2 b)( Measurement of voltage ratio and check of
phase displacemen) |
- |
3500 |
|
Charges are mentioned for 33kV, 2500 kVA, 3 Phase Distribution Transformer. |
21.2 c)( Measurement of short-circuit impedance
(principal tapping, when applicable) and load
loss at 50 percent and 100 percent load) |
- |
4500 |
|
Charges are mentioned for 33kV, 2500 kVA, 3 Phase Distribution Transformer. |
21.2 d)(Measurement of no-load loss and current) |
- |
7000 |
|
Charges are mentioned for 33kV, 2500 kVA, 3 Phase Distribution Transformer. |
21.2 e)(Measurement of insulation resistance) |
- |
3000 |
|
Charges are mentioned for 33kV, 2500 kVA, 3 Phase Distribution Transformer. |
21.2 f)(Induced over-voltage withstand test) |
- |
4500 |
|
Charges are mentioned for 33kV, 2500 kVA, 3 Phase Distribution Transformer. |
21.2 g)( Separate-source voltage withstand test) |
- |
4500 |
|
Charges are mentioned for 33kV, 2500 kVA, 3 Phase Distribution Transformer. |
21.5.3.3(Oil leakage test) |
- |
4500 |
|
Charges are mentioned for 33kV, 2500 kVA, 3 Phase Distribution Transformer. |
21.3(a )(Lightning impulse test) |
- |
75000 |
|
Charges are mentioned for 33kV, 2500 kVA, 3 Phase Distribution Transformer. |
21.3(b)(Temperature-rise test) |
- |
40000 |
|
Charges are mentioned for 33kV, 2500 kVA, 3 Phase Distribution Transformer. |
21.4 a)( Determination of sound levels) |
- |
15000 |
|
Charges are mentioned for 33kV, 2500 kVA, 3 Phase Distribution Transformer. |
21.5.1.2(Pressure test-routine test (For Transformers up to 200 kVA
)) |
- |
2500 |
|
Charges are mentioned for 33kV, 200 kVA, 3 Phase Distribution Transformer. |
21.5.1.1(Pressure test-Type test (For Transformers up to 200 kVA
)) |
- |
7500 |
|
Charges are mentioned for 33kV, 200 kVA, 3 Phase Distribution Transformer. |
21.5.2.2(routine test :For Transformers Above 200 kVA and Up to Including 2 500 kVA) |
- |
4000 |
|
Charges are mentioned for 33kV, 2500 kVA, 3 Phase Distribution Transformer. |
21.5.2.1(Type test : For Transformers Above 200 kVA and Up to Including 2 500 kVA) |
- |
10000 |
|
Charges are mentioned for 33kV, 2500 kVA, 3 Phase Distribution Transformer. |
21.4 d(Paint adhesion tests) |
- |
12500 |
|
Charges are mentioned for 33kV, 2500 kVA, 3 Phase Distribution Transformer. |
21.4 e(BDV and moisture content of oil in the transformer) |
- |
12500 |
|
Charges are mentioned for 33kV, 2500 kVA, 3 Phase Distribution Transformer. |
21.4 c(No load current at 112.5 percent voltage.) |
- |
15000 |
|
Charges are mentioned for 33kV, 2500 kVA, 3 Phase Distribution Transformer. |
21.5.2.3( Oil leakage test (routine test)) |
- |
4500 |
|
Charges are mentioned for 33kV, 2500 kVA, 3 Phase Distribution Transformer. |
21.5.3.1(For Single Phase Distribution Transformers Up to Including 25 kVA : pressure test (type test)) |
- |
7500 |
|
Charges are mentioned for upto 25 kVA, 1 Phase Distribution Transformer. |
21.5.3.2(For Single Phase Distribution Transformers Up to Including 25 kVA : pressure test (routine test)) |
- |
2500 |
|
Charges are mentioned for Upto 25 kVA, 1 Phase Distribution Transformer. |
21.5.1.3(Oil leakage test upto 200 KVA) |
- |
4500 |
|
Charges are mentioned for 33kV, 200 kVA, 3 Phase Distribution Transformer. |
6.8 (50%)(Total losses at 50 % load (Watts)) |
- |
2250 |
|
Charges are mentioned upto 33kV, 3 Phase Distribution Transformer. |
7.8 (50%)(Total losses at 50 % load (Watts)) |
- |
2250 |
|
Charges are mentioned upto 33kV, 3 Phase Distribution Transformer. |
8.8 (50%)(Total losses at 50 % load (Watts)) |
- |
2250 |
|
Charges are mentioned upto 33kV, 3 Phase Distribution Transformer. |
6.8 (100%)(Total losses at 100 % load (Watts)) |
- |
2250 |
|
Charges are mentioned upto 33kV, 3 Phase Distribution Transformer. |
7.8 (100%)(Total losses at 100 % load (Watts)) |
- |
2250 |
|
Charges are mentioned upto 33kV, 3 Phase Distribution Transformer. |
8.8 (100%)(Total losses at 100 % load (Watts)) |
- |
2250 |
|
Charges are mentioned upto 33kV, 3 Phase Distribution Transformer. |
6.9, 7.9, 8.9(Permissible Flux Density and Over Fluxing) |
- |
15000 |
|
Charges are mentioned upto 33kV, 3 Phase Distribution Transformer. |
15.2(Pressure and Vacuum Requirements) |
- |
10000 |
|
Charges are mentioned upto 33kV, 3 Phase Distribution Transformer. |
6.5(No-Load Voltage Ratios) |
- |
3500 |
|
Charges are mentioned upto 33kV, 3 Phase Distribution Transformer. |
6.6(Winding connections and phase displacement) |
- |
3500 |
|
Charges are mentioned upto 33kV, 3 Phase Distribution Transformer. |
6.1(Limits of Temperature-rise) |
- |
40000 |
|
Charges are mentioned upto 33kV, 3 Phase Distribution Transformer. |
13.1(Marking (Rating Plates)) |
- |
0 |
|
Visual inspection |
13.2(Terminal Marking Plate) |
- |
0 |
|
Visual inspection |
13.3(Marking ) |
- |
0 |
|
Visual inspection |
13.4(Marking) |
- |
0 |
|
Visual inspection |
13.4.1(Marking) |
- |
0 |
|
Visual inspection |
14.1(MOUNTING ARRANGEMENT) |
- |
0 |
|
Visual inspection |
14.2(MOUNTING ARRANGEMENT) |
- |
0 |
|
Visual inspection |
14.3(MOUNTING ARRANGEMENT) |
- |
0 |
|
Visual inspection |
14.4(MOUNTING ARRANGEMENT) |
- |
0 |
|
Visual inspection |
15.1.1(TRANSFORMER TANK : Construction) |
- |
0 |
|
Visual inspection |
15.1.2(TRANSFORMER TANK : Construction) |
- |
0 |
|
Visual inspection |
15.1.3(TRANSFORMER TANK : Construction) |
- |
0 |
|
Visual inspection |
15.1.4(TRANSFORMER TANK : Construction) |
- |
0 |
|
Visual inspection |
15.1.5(TRANSFORMER TANK : Construction) |
- |
0 |
|
Visual inspection |
15.5(Total Dry Film Paint Thickness) |
- |
0 |
|
Visual inspection |
11(Minimum clearance in Air) |
- |
0 |
|
Visual inspection |
16(Conservator for Non-sealed type Transformers) |
- |
0 |
|
Visual inspection |
20(Fittings) |
- |
0 |
|
Visual inspection |
9.1a)(CRGO Electrical Steel) |
- |
0 |
|
delared parameter |
9.1 b)(Amorphous core material) |
- |
0 |
|
delared parameter |
9.1 c)(Copper/Aluminium conductor) |
- |
0 |
|
delared parameter |
9.1 d)(Kraft paper) |
- |
0 |
|
delared parameter |
9.1 e)(Press Board) |
- |
0 |
|
delared parameter |
9.1 f)(Mineral oil) |
- |
0 |
|
delared parameter |
10(Terminal Arrangement) |
- |
0 |
|
delared parameter |
15.4(Gasket) |
- |
0 |
|
delared parameter |
19(Tolerances) |
- |
0 |
|
delared parameter |
18(Efficiency and regulation) |
- |
0 |
|
delared parameter |
4(Service Conditions) |
- |
0 |
|
delared parameter |
5(General ) |
- |
0 |
|
delared parameter |
6.1(Rating) |
- |
0 |
|
delared parameter |
6.2(Rated frequency) |
- |
0 |
|
delared parameter |
6.3(Nominal system voltage) |
- |
0 |
|
delared parameter |
6.4(Basic Insulation level ) |
- |
0 |
|
delared parameter |
6.7(Tapping Range and Tapping Method) |
- |
0 |
|
delared parameter |
7(Technical Parameters of three phase distribution trasnformers
higher than 200kva) |
- |
0 |
|
delared parameter |
8(Technical Parameters of single phase distribution transformers
UP to and including 25 KVA ) |
- |
0 |
|
delared parameter |
9(Standard Materials) |
- |
0 |
|
delared parameter |
10(Terminal arrangment ) |
- |
0 |
|
delared parameter |
11(Minimum Clearnaces air ) |
- |
0 |
|
delared parameter |
12(Connectors ) |
- |
0 |
|
delared parameter |
13(Marking ) |
- |
0 |
|
Visual inspection |
14(Mounting arrangement) |
- |
0 |
|
delared parameter |
15(Trasnformer Tank ) |
- |
0 |
|
delared parameter |
16(Conservator for Non-Sealed type Transformers) |
- |
0 |
|
Visual inspection |
18(Efficiency and Regulation) |
- |
0 |
|
Visual inspection |
19(Tolerances) |
- |
0 |
|
Visual inspection |
20(Fittings) |
- |
0 |
|
Visual inspection |
21(General ) |
- |
0 |
|
Visual inspection |
22(Information required with enquiry and order ) |
- |
0 |
|
Visual inspection |
17( ABILITY OF TRANSFORMERS TO
WITHSTAND EXTERNAL SHORT CIRCUIT
) |
- |
0 |
|
Declared parameter |
17(Ability of transformers to withstand external Short circuit ) |
- |
0 |
|
Declared parameter |
21.5.3.3(Oil leakage test (routine test)) |
- |
0 |
|
Repeated |
6.8(Losses and impedance values) |
- |
0 |
|
Repeated |
6.9(Permissible Flux Density and Over Fluxing ) |
- |
0 |
|
Repeated |
|
Complete
|
|
17 Jul, 2026 |
- - |
15 |
RTRC LIMITED
| IS 1180 : Part 1 (2014) |
Outdoor Type Oil Immersed Distribution Transformers Upto and Including 2 500 kVA, 33kV - Specification Part 1 Mineral Oil Immersed (Fourth Revision) |
Mineral Oil Immersed Distribution Transformers |
-
|
120000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
21.2 a)(Measurement of winding resistance ) |
- |
6000 |
|
Complete Testing Charges : Rs.76000/- For 0 to 100 kVA, Rs.86100/- For 100 to 250 kVA, Rs.92000- For 250 kVA to 630 kVA, Rs.93100/- For 630 kVA to 1000 kVA, Rs.117900/- For 1000 kVA to 1600 kVA. Rs.120000/- For 1600 kVA to 2500 kVA. |
21.2 b)( Measurement of voltage ratio and check of
phase displacemen) |
- |
5000 |
|
- |
21.2 c)( Measurement of short-circuit impedance
(principal tapping, when applicable) and load
loss at 50 percent and 100 percent load) |
- |
5000 |
|
- |
21.2 d)(Measurement of no-load loss and current) |
- |
3500 |
|
- |
21.2 e)(Measurement of insulation resistance) |
- |
2000 |
|
- |
21.2 f)(Induced over-voltage withstand test) |
- |
4500 |
|
- |
21.2 g)( Separate-source voltage withstand test) |
- |
4000 |
|
- |
21.5.1.2(Pressure test-routine test (For Transformers up to 200 kVA
)) |
- |
4000 |
|
- |
21.5.1.3(Oil leakage test upto 200 KVA) |
- |
3000 |
|
- |
21.3(a )(Lightning impulse test) |
- |
38000 |
|
- |
21.3(b)(Temperature-rise test) |
- |
23000 |
|
- |
21.5.1.1(Pressure test-Type test (For Transformers up to 200 kVA
)) |
- |
6000 |
|
- |
21.4 a)( Determination of sound levels) |
- |
6000 |
|
- |
21.4 c(No load current at 112.5 percent voltage.) |
- |
1000 |
|
- |
21.4 d(Paint adhesion tests) |
- |
1500 |
|
- |
21.4 e(BDV and moisture content of oil in the transformer) |
- |
1500 |
|
- |
6.9(Permissible Flux Density and Over Fluxing ) |
- |
6000 |
|
- |
13.1(Marking (Rating Plates)) |
- |
0 |
|
- |
13.2(Terminal Marking Plate) |
- |
0 |
|
- |
13.3(Marking ) |
- |
0 |
|
- |
13.4(Marking) |
- |
0 |
|
- |
13.4.1(Marking) |
- |
0 |
|
- |
14.1(MOUNTING ARRANGEMENT) |
- |
0 |
|
- |
14.2(MOUNTING ARRANGEMENT) |
- |
0 |
|
- |
14.3(MOUNTING ARRANGEMENT) |
- |
0 |
|
- |
14.4(MOUNTING ARRANGEMENT) |
- |
0 |
|
- |
15.1.1(TRANSFORMER TANK : Construction) |
- |
0 |
|
- |
15.1.2(TRANSFORMER TANK : Construction) |
- |
0 |
|
- |
15.1.3(TRANSFORMER TANK : Construction) |
- |
0 |
|
- |
15.1.4(TRANSFORMER TANK : Construction) |
- |
0 |
|
- |
15.1.5(TRANSFORMER TANK : Construction) |
- |
0 |
|
- |
21.5.3.3(Oil leakage test) |
- |
0 |
|
- |
21.5.2.1(Type test : For Transformers Above 200 kVA and Up to Including 2 500 kVA) |
- |
120000 |
|
- |
21.5.2.2(routine test :For Transformers Above 200 kVA and Up to Including 2 500 kVA) |
- |
37000 |
|
Routine Testing Charges : Rs.19100/- For 0 to 100 kVA, Rs.22200/- For 100 to 250 kVA, Rs.24700/- For 250 kVA to 630 kVA, Rs.25600/- For 630 kVA to 1000 kVA, Rs.33100/- For 1000 kVA to 1600 kVA. Rs.37000/- For 1600 kVA to 2500 kVA. |
21.5.2.3( Oil leakage test (routine test)) |
- |
0 |
|
- |
21.5.3.1(For Single Phase Distribution Transformers Up to Including 25 kVA : pressure test (type test)) |
- |
0 |
|
- |
21.5.3.2(For Single Phase Distribution Transformers Up to Including 25 kVA : pressure test (routine test)) |
- |
0 |
|
- |
21.5.3.3(Oil leakage test (routine test)) |
- |
0 |
|
- |
15.5(Total Dry Film Paint Thickness) |
- |
0 |
|
- |
6.9, 7.9, 8.9(Permissible Flux Density and Over Fluxing) |
- |
0 |
|
- |
11(Minimum clearance in Air) |
- |
0 |
|
- |
16(Conservator for Non-sealed type Transformers) |
- |
0 |
|
- |
20(Fittings) |
- |
0 |
|
- |
6.8 (50%)(Total losses at 50 % load (Watts)) |
- |
0 |
|
- |
7.8 (50%)(Total losses at 50 % load (Watts)) |
- |
0 |
|
- |
8.8 (50%)(Total losses at 50 % load (Watts)) |
- |
0 |
|
- |
6.8 (100%)(Total losses at 100 % load (Watts)) |
- |
0 |
|
- |
7.8 (100%)(Total losses at 100 % load (Watts)) |
- |
0 |
|
- |
8.8 (100%)(Total losses at 100 % load (Watts)) |
- |
0 |
|
- |
9.1a)(CRGO Electrical Steel) |
- |
0 |
|
- |
9.1 b)(Amorphous core material) |
- |
0 |
|
- |
9.1 c)(Copper/Aluminium conductor) |
- |
0 |
|
- |
9.1 d)(Kraft paper) |
- |
0 |
|
- |
9.1 e)(Press Board) |
- |
0 |
|
- |
9.1 f)(Mineral oil) |
- |
0 |
|
- |
10(Terminal Arrangement) |
- |
0 |
|
- |
15.2(Pressure and Vacuum Requirements) |
- |
0 |
|
- |
15.4(Gasket) |
- |
0 |
|
- |
19(Tolerances) |
- |
0 |
|
- |
18(Efficiency and regulation) |
- |
0 |
|
- |
4(Service Conditions) |
- |
0 |
|
- |
5(General ) |
- |
0 |
|
- |
6.1(Rating) |
- |
0 |
|
- |
6.2(Rated frequency) |
- |
0 |
|
- |
6.3(Nominal system voltage) |
- |
0 |
|
- |
6.4(Basic Insulation level ) |
- |
0 |
|
- |
6.5(No-Load Voltage Ratios) |
- |
0 |
|
- |
6.6(Winding connections and phase displacement) |
- |
0 |
|
- |
6.7(Tapping Range and Tapping Method) |
- |
0 |
|
- |
6.8(Losses and impedance values) |
- |
0 |
|
- |
6.1(Limits of Temperature-rise) |
- |
0 |
|
- |
7(Technical Parameters of three phase distribution trasnformers
higher than 200kva) |
- |
0 |
|
- |
8(Technical Parameters of single phase distribution transformers
UP to and including 25 KVA ) |
- |
0 |
|
- |
9(Standard Materials) |
- |
0 |
|
- |
10(Terminal arrangment ) |
- |
0 |
|
- |
11(Minimum Clearnaces air ) |
- |
0 |
|
- |
12(Connectors ) |
- |
0 |
|
- |
13(Marking ) |
- |
0 |
|
- |
14(Mounting arrangement) |
- |
0 |
|
- |
15(Trasnformer Tank ) |
- |
0 |
|
- |
16(Conservator for Non-Sealed type Transformers) |
- |
0 |
|
- |
18(Efficiency and Regulation) |
- |
0 |
|
- |
19(Tolerances) |
- |
0 |
|
- |
21(General ) |
- |
0 |
|
- |
22(Information required with enquiry and order ) |
- |
0 |
|
- |
20(Fittings) |
- |
0 |
|
- |
|
Complete
|
|
03 Apr, 2027 |
- Exclusion: Cl.21.4 b (Short-circuit withstand test IS 2026 (Part 5) (above 200 kVA)), Cl. 17 ( ABILITY OF TRANSFORMERS TO WITHSTAND EXTERNAL SHORT CIRCUIT), Cl. 21.3(c) (Short-circuit withstand test) |
16 |
Electrical Research and Testing Organisation
| IS 1180 : Part 3 (2021) |
Outdoor/Indoor Type Liquid Immersed Distribution Transformers Up to and Including 2 500 kVA, 33 kV — Specification Part 3 Natural/Synthetic Organic Ester Liquid Immersed |
up to and including 2500 kVA |
-
|
214450 View breakup
Up to 200 kVA (For single phase and Three phase)
10 kVA for routine test - Rs.11,950/-, for type test - Rs.99,200/-(including Short circuit test), for special test - Rs.7,000/-, For complete testing with short circuit – Rs.1,18,150/-;
16 kVA for routine test - Rs.12,350/-, for type test - Rs.1,00,200/-(including Short circuit test), for special test - Rs.7,000/-, For complete testing with short circuit – Rs.1,19,550/-;
25 kVA for routine test - Rs.12,850/-, for type test - Rs.1,01,200/-(including Short circuit test), for special test - Rs.7,000/-, For complete testing with short circuit – Rs.1,21,050/-;
63 kVA for routine test - Rs.13,850/-, for type test - Rs.1,06,700/-(including Short circuit test), for special test - Rs.7,000/-, For complete testing with short circuit – Rs.1,27,550/-;
100 kVA for routine test - Rs.14,850/-, for type test - Rs.1,08,700/-(including Short circuit test), for special test - Rs.7,000/-, For complete testing with short circuit – Rs.1,30,550/-;
160 kVA (without tap) for routine test - Rs.15,850/-, for type test - Rs.1,27,500/-(including Short circuit test), for special test - Rs.7,000/-, For complete testing with short circuit – Rs.1,50,350/-;
160 kVA (Up to 4 tap) for routine test - Rs.18,700/-, for type test - Rs. 1,27,500/-(including Short circuit test), for special test - Rs.7,000/-, For complete testing with short circuit – Rs.1,53,200/-;
160 kVA (Up to 7 tap) for routine test - Rs.21,550/-, for type test - Rs. 1,27,500/-(including Short circuit test), for special test - Rs.7,000/-, For complete testing with short circuit – Rs.1,56,050/-;
160 kVA (Up to 9 tap) for routine test - Rs.23,450/-, for type test - Rs. 1,27,500/-(including Short circuit test), for special test - Rs.7,000/-, For complete testing with short circuit – Rs.1,56,950/-;
200 kVA (without tap) for routine test - Rs.16,350/-, for type test - Rs.1,35,200/-(including Short circuit test), for special test - Rs.7,000/-, For complete testing with short circuit – Rs.1,57,000/-;
200 kVA (Up to 4 tap) for routine test - Rs.19,200/-, for type test - Rs.1,35,200/-(including Short circuit test), for special test - Rs.7,000/-, For complete testing with short circuit – Rs. 1,57,000/-;
200 kVA (Up to 7 tap) for routine test - Rs.22,050/-, for type test - Rs.1,35,200/-(including Short circuit test), for special test - Rs.7,000/-, For complete testing with short circuit – Rs. 1,57,000/-;
200 kVA (Up to 9 tap) for routine test - Rs.23,950/-, for type test - Rs.1,35,200/-(including Short circuit test), for special test - Rs.7,000/-, For complete testing with short circuit – Rs. 1,57,000/-;
Above 200 kVA up to 2500 kVA (Three phase transformer)
250 kVA (Without tap) for routine test - Rs.16,850/-, for type test - Rs.50,000/-, for special test - Rs.7,000/-(Excluding Short circuit test), For complete testing without short circuit – Rs.73,850/-;
250 kVA (Up to 4 Tap) for routine test - Rs.19,700/-, for type test - Rs.50,000/-, for special test - Rs.7,000/-(Excluding Short circuit test), For complete testing without short circuit – Rs.76,700/-;
250 kVA (Up to 7 Tap) for routine test - Rs.22,550/-, for type test - Rs.50,000/-, for special test - Rs.7,000/-(Excluding Short circuit test), For complete testing without short circuit – Rs.79,550/-;
250 kVA (Up to 9 Tap) for routine test - Rs.24,450/-, for type test - Rs.50,000/-, for special test - Rs.7,000/-(Excluding Short circuit test), For complete testing without short circuit – Rs.81,450/-;
250 kVA (Up to 17 Tap) for routine test - Rs.32,050/-, for type test - Rs.50,000/-, for special test - Rs.7,000/-(Excluding Short circuit test), For complete testing without short circuit – Rs.89,050/-;
315 kVA (Without tap) for routine test - Rs.17,600/-, for type test - Rs.54,000/-, for special test - Rs.7,000/-(Excluding Short circuit test), For complete testing without short circuit – Rs.78,600/-;
315 kVA (Up to 4 tap) for routine test - Rs.20,450/-, for type test - Rs.54,000/-, for special test - Rs.7,000/-(Excluding Short circuit test), For complete testing without short circuit – Rs.81,450/-;
315 kVA (UP to 7 tap) for routine test - Rs.23,300/-, for type test - Rs.54,000/-, for special test - Rs.7,000/-(Excluding Short circuit test), For complete testing without short circuit – Rs.84,300/-;
315 kVA (Up to 9 tap) for routine test - Rs.25,200/-, for type test - Rs.54,000/-, for special test - Rs.7,000/-(Excluding Short circuit test), For complete testing without short circuit – Rs.86,200/-;
315 kVA (Up to 17 tap) for routine test - Rs.32,800/-, for type test - Rs.54,000/-, for special test - Rs.7,000/-(Excluding Short circuit test), For complete testing without short circuit – Rs.93,800/-;
400 kVA (Without tap) for routine test - Rs.17,600/-, for type test - Rs.54,000/-, for special test - Rs.7,000/-(Excluding Short circuit test), For complete testing without short circuit – Rs.78,600/-;
400 kVA (Up to 4 tap) for routine test - Rs.20,450/-, for type test - Rs.54,000/-, for special test - Rs.7,000/-(Excluding Short circuit test), For complete testing without short circuit – Rs.81,450/-;
400 kVA (UP to 7 tap) for routine test - Rs.23,300/-, for type test - Rs.54,000/-, for special test - Rs.7,000/-(Excluding Short circuit test), For complete testing without short circuit – Rs.84,300/-;
400 kVA (Up to 9 tap) for routine test - Rs.25,200/-, for type test - Rs.54,000/-, for special test - Rs.7,000/-(Excluding Short circuit test), For complete testing without short circuit – Rs.86,200/-;
400 kVA (Up to 17 tap) for routine test - Rs.32,800/-, for type test - Rs.54,000/-, for special test - Rs.7,000/-(Excluding Short circuit test), For complete testing without short circuit – Rs.93,800/-;
500 kVA (Without tap) for routine test - Rs.18,600/-, for type test - Rs.54,000/-, for special test - Rs.7,000/-(Excluding Short circuit test), For complete testing without short circuit – Rs.79,600/-;
500 kVA (Up to 4 tap) for routine test - Rs.21,450/-, for type test - Rs.54,000/-, for special test - Rs.7,000/-(Excluding Short circuit test), For complete testing without short circuit – Rs.82,450/-;
500 kVA (Up to 7 tap) for routine test - Rs.24,300/-, for type test - Rs.54,000/-, for special test - Rs.7,000/-(Excluding Short circuit test), For complete testing without short circuit – Rs.85,300/-;
500 kVA (Up to 9 tap) for routine test - Rs.26,200/-, for type test - Rs.54,000/-, for special test - Rs.7,000/-(Excluding Short circuit test), For complete testing without short circuit – Rs.87,200/-;
500 kVA (Up to 17 tap) for routine test - Rs.33,800/-, for type test - Rs.54,000/-, for special test - Rs.7,000/-(Excluding Short circuit test), For complete testing without short circuit – Rs.94,800/-;
630 kVA (Without tap) for routine test - Rs.19,400/-, for type test - Rs.67,000/-, for special test - Rs.7,000/-(Excluding Short circuit test), For complete testing without short circuit – Rs.93,400/-;
630 kVA (Up to 4 tap) for routine test - Rs.22,250/-, for type test - Rs.67,000/-, for special test - Rs.7,000/-(Excluding Short circuit test), For complete testing without short circuit – Rs.92,250/-;
630 kVA (Up to 7 tap) for routine test - Rs.25,100/-, for type test - Rs.67,000/-, for special test - Rs.7,000/-(Excluding Short circuit test), For complete testing without short circuit – Rs.99,100/-;
630 kVA (Up to 9 tap) for routine test - Rs.27,000/-, for type test - Rs.67,000/-, for special test - Rs.7,000/-(Excluding Short circuit test), For complete testing without short circuit – Rs.1,01,000/-;
630 kVA (Up to 17 tap) for routine test - Rs.34,600/-, for type test - Rs.67,000/-, for special test - Rs.7,000/-(Excluding Short circuit test), For complete testing without short circuit – Rs.1,08,600/-;
750 kVA (Without tap) for routine test - Rs.20,700/-, for type test - Rs.67,000/-, for special test - Rs.7,000/-(Excluding Short circuit test), For complete testing without short circuit – Rs.94,700/-;
750 kVA (Up to 4 tap) for routine test - Rs.23,550/-, for type test - Rs.67,000/-, for special test - Rs.7,000/-(Excluding Short circuit test), For complete testing without short circuit – Rs.97,550/-;
750 kVA (Up to 7 tap) for routine test - Rs.26,400/-, for type test - Rs.67,000/-, for special test - Rs.7,000/-(Excluding Short circuit test), For complete testing without short circuit – Rs.1,00,400/-;
750 kVA (Up to 9 tap) for routine test - Rs.28,300/-, for type test - Rs.67,000/-, for special test - Rs.7,000/-(Excluding Short circuit test), For complete testing without short circuit – Rs.1,02,300/-;
750 kVA (Up to 17 tap) for routine test - Rs.35,900/-, for type test - Rs.67,000/-, for special test - Rs.7,000/-(Excluding Short circuit test), For complete testing without short circuit – Rs.1,09,900/-;
751 to 1000 kVA (Without tap) for routine test - Rs.21,800/-, for type test - Rs.67,000/-, for special test - Rs.7,000/-(Excluding Short circuit test), For complete testing without short circuit – Rs.95,800/-;
751 to 1000 kVA (Up to 4 tap) for routine test - Rs.24,650/-, for type test - Rs.67,000/-, for special test - Rs.7,000/-(Excluding Short circuit test), For complete testing without short circuit – Rs.98,650/-;
751 to 1000 kVA (Up to 7 tap) for routine test - Rs.27,500/-, for type test - Rs.67,000/-, for special test - Rs.7,000/-(Excluding Short circuit test), For complete testing without short circuit – Rs.1,01,500/-;
751 to 1000 kVA (Up to 9 tap) for routine test - Rs.29,400/-, for type test - Rs.67,000/-, for special test - Rs.7,000/-(Excluding Short circuit test), For complete testing without short circuit – Rs.1,03,400/-;
751 to 1000 kVA (Up to 17 tap) for routine test - Rs.37,000/-, for type test - Rs.67,000/-, for special test - Rs.7,000/-(Excluding Short circuit test), For complete testing without short circuit – Rs.1,11,000/-;
1250 kVA (Without tap) for routine test - Rs.23,200/-, for type test - Rs.79,000/-, for special test - Rs.7,000/-(Excluding Short circuit test), For complete testing without short circuit – Rs.1,09,200/-;
1250 kVA (Up to 4 tap) for routine test - Rs.26,050/-, for type test - Rs.79,000/-, for special test - Rs.7,000/-(Excluding Short circuit test), For complete testing without short circuit – Rs.1,12,050/-;
1250 kVA (Up to 7 tap) for routine test - Rs.28,900/-, for type test - Rs.79,000/-, for special test - Rs.7,000/-(Excluding Short circuit test), For complete testing without short circuit – Rs.1,14,900/-;
1250 kVA (Up to 9 tap) for routine test - Rs.30,800/-, for type test - Rs.79,000/-, for special test - Rs.7,000/-(Excluding Short circuit test), For complete testing without short circuit – Rs.1,16,800/-;
1250 kVA (Up to 17 tap) for routine test - Rs.38,400/-, for type test - Rs.79,000/-, for special test - Rs.7,000/-(Excluding Short circuit test), For complete testing without short circuit – Rs.1,24,400/-;
1600 kVA (Without tap) for routine test - Rs.23,550/-, for type test - Rs.79,000/-, for special test - Rs.7,000/-(Excluding Short circuit test), For complete testing without short circuit – Rs.1,09,550/-;
1600 kVA (Up to 4 tap) for routine test - Rs.26,900/-, for type test - Rs.79,000/-, for special test - Rs.7,000/-(Excluding Short circuit test), For complete testing without short circuit – Rs.1,12,900/-;
1600 kVA (Up to 7 tap) for routine test - Rs.29,750/-, for type test - Rs.79,000/-, for special test - Rs.7,000/-(Excluding Short circuit test), For complete testing without short circuit – Rs.1,15,750/-;
1600 kVA (Up to 9 tap) for routine test - Rs.31,650/-, for type test - Rs.79,000/-, for special test - Rs.7,000/-(Excluding Short circuit test), For complete testing without short circuit – Rs.1,17,650/-;
1600 kVA (Up to 17 tap) for routine test - Rs.39,250/-, for type test - Rs.79,000/-, for special test - Rs.7,000/-(Excluding Short circuit test), For complete testing without short circuit – Rs.1,25,250/-;
2000 kVA (Without tap) for routine test - Rs.24,200/-, for type test - Rs.79,000/-, for special test - Rs.7,000/-(Excluding Short circuit test), For complete testing without short circuit – Rs.1,10,200/-;
2000 kVA (Up to 4 tap) for routine test - Rs.27,550/-, for type test - Rs.79,000/-, for special test - Rs.7,000/-(Excluding Short circuit test), For complete testing without short circuit – Rs.1,13,550/-;
2000 kVA (Up to 7 tap) for routine test - Rs.30,400/-, for type test - Rs.79,000/-, for special test - Rs.7,000/-(Excluding Short circuit test), For complete testing without short circuit – Rs.1,16,400/-;
2000 kVA (Up to 9 tap) for routine test - Rs.32,300/-, for type test - Rs.79,000/-, for special test - Rs.7,000/-(Excluding Short circuit test), For complete testing without short circuit – Rs.1,18,300/-;
2000 kVA (Up to 17 tap) for routine test - Rs.39,900/-, for type test - Rs.79,000/-, for special test - Rs.7,000/-(Excluding Short circuit test), For complete testing without short circuit – Rs.1,25,900/-;
2500 kVA (Without tap) for routine test - Rs.24,550/-, for type test - Rs.79,000/-, for special test - Rs.7,000/-(Excluding Short circuit test), For complete testing without short circuit – Rs.1,10,550/-;
2500 kVA (Up to 4 tap) for routine test - Rs.27,900/-, for type test - Rs.79,000/-, for special test - Rs.7,000/-(Excluding Short circuit test), For complete testing without short circuit – Rs.1,13,900/-;
2500 kVA (Up to 7 tap) for routine test - Rs.30,750/-, for type test - Rs.79,000/-, for special test - Rs.7,000/-(Excluding Short circuit test), For complete testing without short circuit – Rs.1,16,750/-;
2500 kVA (Up to 9 tap) for routine test - Rs.32,650/-, for type test - Rs.79,000/-, for special test - Rs.7,000/-(Excluding Short circuit test), For complete testing without short circuit – Rs.1,18,650/-;
2500 kVA (Up to 17 tap) for routine test - Rs.40,250/-, for type test - Rs.79,000/-, for special test - Rs.7,000/-(Excluding Short circuit test), For complete testing without short circuit – Rs.1,26,250/-;
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
21.2 a(Measurement of winding resistance
[IS 2026 (Part 1)].) |
- |
7050 |
|
Test charges consider for 2500 kVA, 17 Tap Transformer |
21.2 b(Measurement of voltage ratio and check of phase
displacement [IS 2026 (Part 1)].) |
- |
9650 |
|
Test charges consider for 2500 kVA, 17 Tap Transformer |
21.2 c(Measurement of short-circuit impedance
(principal tapping, when applicable) and load
loss at 50 percent and 100 percent load
[IS 2026 (Part 1)].) |
- |
7000 |
|
Test charges consider for 2500 kVA, 17 Tap Transformer |
21.2 d(Measurement of no-load loss and current
[IS 2026 (Part 1)].) |
- |
4500 |
|
Test charges consider for 2500 kVA, 17 Tap Transformer |
21.2 e(Measurement of insulation resistance
[IS 2026 (Part 1)].) |
- |
550 |
|
Test charges consider for 2500 kVA, 17 Tap Transformer |
21.2 f(Induced over-voltage withstand test
[IS 2026 (Part 3)].) |
- |
1000 |
|
Test charges consider for 2500 kVA, 17 Tap Transformer |
21.2 g(Separate-source voltage withstand test
[IS 2026 (Part 3)]) |
- |
1000 |
|
Test charges consider for 2500 kVA, 17 Tap Transformer |
21.5(Pressure and Ester Liquid Leakage Test) |
- |
9500 |
|
Test charges consider for 2500 kVA, 17 Tap Transformer |
21.3 a(Lightning impulse test [IS 2026 (Part 3)].) |
- |
65000 |
|
Test charges consider for 2500 kVA, 17 Tap Transformer |
21.3 b(Temperature-rise test [IS 2026 (Part 2)].) |
- |
20000 |
|
Test charges consider for 2500 kVA, 17 Tap Transformer |
21.3 c(Short-circuit withstand test [IS 2026 (Part 5)]
(up to 200 kVA) and) |
- |
62700 |
|
Test charges given for up to 100 kVA. So test charges vary by rating of transformer |
21.3 d(Pressure test) |
- |
9000 |
|
Test charges consider for 2500 kVA, 17 Tap Transformer |
21.4 a(Determination of sound levels [IS 2026 (Part 10)];) |
- |
2500 |
|
Test charges consider for 2500 kVA, 17 Tap Transformer |
21.4 c(No load current at 112.5 percent voltage
(see 6.9.2, 7.9.2, 8.9.2);) |
- |
1500 |
|
-- |
21.4 d(Paint adhesion test — The test is performed as
per ASTM D3359 (Standard Test Methods for
measuring adhesion by tape test).) |
- |
1000 |
|
- |
21.4 e(BDV and Moisture content of liquid in the
transformer (IS 16081, IS 16099, IS 16899 or
IS 16659, whichever is applicable).) |
- |
7000 |
|
- |
11(Minimum clearances in air) |
- |
1000 |
|
- |
11(Minimum clearances in air) |
- |
1000 |
|
- |
14(Mounting Arrangement) |
- |
1000 |
|
- |
14(Mounting Arrangement) |
- |
1000 |
|
- |
16(Conservator for non-sealed typetransformers) |
- |
1000 |
|
- |
16(Conservator for non-sealed type transformers) |
- |
1000 |
|
- |
20(Fittings) |
- |
1000 |
|
- |
20(Fittings) |
- |
1000 |
|
- |
17(Ability of Transformers to withstand external short circuit) |
- |
62700 |
|
Test charges given for up to 100 kVA. So test charges vary by rating of transformer |
17(Ability of transformers to whitstand external short circuit) |
- |
62700 |
|
Test charges given for up to 100 kVA. So test charges vary by rating of transformer |
6.8(Table 3 Losses and Impedance Values) |
- |
0 |
|
- |
6.8(Losses and Impedance Value) |
- |
0 |
|
- |
7.8(Losses and Impedance Values) |
- |
0 |
|
- |
8.8(Losses and Impedance Values) |
- |
0 |
|
- |
6.4(Table 2 Minimum Basic Insulation Level) |
- |
0 |
|
- |
6.9(Permissible Flux Density and Over Fluxing) |
- |
1500 |
|
Test charges consider for 2500 kVA, 17 Tap Transformer |
7.4(Table 5 Minimum Basic Insulation Level) |
- |
65000 |
|
Test charges consider for 2500 kVA, 17 Tap Transformer |
7.9(Permissible Flux Density and Overfluxing) |
- |
1500 |
|
- |
8.4(Table 8 Minimum Basic Insulation Level) |
- |
65000 |
|
Test charges consider for 2500 kVA, 17 Tap Transformer |
8.9(Permissible Flux Density and Overfluxing) |
- |
1500 |
|
- |
6.4(Basic Insulation Level) |
- |
65000 |
|
Test charges consider for 2500 kVA, 17 Tap Transformer |
6.9(Permissible flux density and over fluxing) |
- |
1500 |
|
- |
21.5(Pressure and Ester Liquid Leakage Test) |
- |
9000 |
|
- |
21.2 a(Measurement of winding resistance
[IS 2026 (Part 1)].) |
- |
7050 |
|
Test charges consider for 2500 kVA, 17 Tap Transformer |
21.2 b(Measurement of voltage ratio and check of phase
displacement [IS 2026 (Part 1)].) |
- |
9650 |
|
Test charges consider for 2500 kVA, 17 Tap Transformer |
21.2 c(Measurement of short-circuit impedance
(principal tapping, when applicable) and load
loss at 50 percent and 100 percent load
[IS 2026 (Part 1)].) |
- |
7000 |
|
Test charges consider for 2500 kVA, 17 Tap Transformer |
21.2 d(Measurement of no-load loss and current
[IS 2026 (Part 1)].) |
- |
4500 |
|
Test charges consider for 2500 kVA, 17 Tap Transformer |
21.2 e(Measurement of insulation resistance
[IS 2026 (Part 1)].) |
- |
550 |
|
Test charges consider for 2500 kVA, 17 Tap Transformer |
21.2 f(Induced over-voltage withstand test
[IS 2026 (Part 3)].) |
- |
1000 |
|
Test charges consider for 2500 kVA, 17 Tap Transformer |
21.2 g(Separate-source voltage withstand test
[IS 2026 (Part 3)]) |
- |
1000 |
|
Test charges consider for 2500 kVA, 17 Tap Transformer |
21.5(Pressure and Ester Liquid Leakage Test) |
- |
9500 |
|
Test charges consider for 2500 kVA, 17 Tap Transformer |
21.3 a(Lightning impulse test [IS 2026 (Part 3)].) |
- |
65000 |
|
Test charges consider for 2500 kVA, 17 Tap Transformer |
21.3 b(Temperature-rise test [IS 2026 (Part 2)].) |
- |
20000 |
|
Test charges consider for 2500 kVA, 17 Tap Transformer |
21.3 c(Short-circuit withstand test [IS 2026 (Part 5)]
(up to 200 kVA) and) |
- |
62700 |
|
- |
21.3 d(Pressure test) |
- |
9000 |
|
Test charges consider for 2500 kVA, 17 Tap Transformer |
21.4 a(Determination of sound levels [IS 2026 (Part 10)];) |
- |
2500 |
|
Test charges consider for 2500 kVA, 17 Tap Transformer |
21.4 c(No load current at 112.5 percent voltage
(see 6.9.2, 7.9.2, 8.9.2);) |
- |
1500 |
|
Test charges consider for 2500 kVA, 17 Tap Transformer |
21.4 d(Paint adhesion test — The test is performed as
per ASTM D3359 (Standard Test Methods for
measuring adhesion by tape test).) |
- |
1000 |
|
Test charges consider for 2500 kVA, 17 Tap Transformer |
21.4 e(BDV and Moisture content of liquid in the
transformer (IS 16081, IS 16099, IS 16899 or
IS 16659, whichever is applicable).) |
- |
7000 |
|
Test charges consider for 2500 kVA, 17 Tap Transformer |
11(Minimum clearances in air) |
- |
1000 |
|
Test charges consider for 2500 kVA, 17 Tap Transformer |
11(Minimum clearances in air) |
- |
1000 |
|
- |
14(Mounting Arrangement) |
- |
1000 |
|
- |
14(Mounting Arrangement) |
- |
1000 |
|
- |
16(Conservator for non-sealed typetransformers) |
- |
1000 |
|
- |
16(Conservator for non-sealed type transformers) |
- |
1000 |
|
- |
20(Fittings) |
- |
1000 |
|
- |
20(Fittings) |
- |
1000 |
|
- |
17(Ability of Transformers to withstand external short circuit) |
- |
62700 |
|
Test charges given for up to 100 kVA. So test charges vary by rating of transformer |
17(Ability of transformers to whitstand external short circuit) |
- |
62700 |
|
Test charges given for up to 100 kVA. So test charges vary by rating of transformer |
6.8(Table 3 Losses and Impedance Values) |
- |
0 |
|
- |
6.8(Losses and Impedance Value) |
- |
0 |
|
- |
7.8(Losses and Impedance Values) |
- |
0 |
|
- |
8.8(Losses and Impedance Values) |
- |
0 |
|
- |
6.4(Table 2 Minimum Basic Insulation Level) |
- |
0 |
|
- |
6.9(Permissible Flux Density and Over Fluxing) |
- |
0 |
|
- |
7.4(Table 5 Minimum Basic Insulation Level) |
- |
0 |
|
- |
7.9(Permissible Flux Density and Overfluxing) |
- |
0 |
|
- |
8.4(Table 8 Minimum Basic Insulation Level) |
- |
0 |
|
- |
8.9(Permissible Flux Density and Overfluxing) |
- |
1500 |
|
- |
6.4(Basic Insulation Level) |
- |
0 |
|
- |
6.9(Permissible flux density and over fluxing) |
- |
1500 |
|
- |
21.5(Pressure and Ester Liquid Leakage Test) |
- |
9000 |
|
- |
6.1 Table 1(Standard Ratings) |
- |
0 |
|
- |
6.2, 7.2, 8.2(Rated Frequency) |
- |
0 |
|
- |
6.3, 7.3(Nominal System Voltage) |
- |
0 |
|
- |
6.5, 7.5(No-Load Voltage Ratios) |
- |
0 |
|
- |
6.6, 7.6(Winding Connections and Phase Displacement) |
- |
0 |
|
- |
6.7(Tapping Range and Tapping Methods) |
- |
0 |
|
- |
6.10(Limits of Temperature-rise) |
- |
0 |
|
- |
7.1(Table 4 Standard Ratings) |
- |
0 |
|
- |
7.7(Tapping Ranges and Tapping Methods) |
- |
0 |
|
- |
7.10(Limits of Temperature Rise) |
- |
0 |
|
- |
8.1 Table 7(Standard Ratings) |
- |
0 |
|
- |
8.3(Nominal System Voltage) |
- |
0 |
|
- |
8.5(No Load Voltage Ratio) |
- |
0 |
|
- |
8.6(Number of Phases and Polarity) |
- |
0 |
|
- |
8.10(Limits of Temperature Rise) |
- |
0 |
|
- |
9(Standard Materials) |
- |
0 |
|
- |
10(Terminal Arrangement) |
- |
0 |
|
- |
12(Connectors (Applicable for bare bushing terminations only)) |
- |
0 |
|
- |
13(Marking) |
- |
0 |
|
- |
15(Transformer Tank) |
- |
0 |
|
- |
18(Efficiency and regulation) |
- |
0 |
|
- |
19(Tolerances) |
- |
0 |
|
- |
4(SERVICE CONDITIONS) |
- |
0 |
|
- |
5(General) |
- |
0 |
|
- |
6.1(Rating) |
- |
0 |
|
- |
6.2(Rated Frequceny) |
- |
0 |
|
- |
6.3(Nominal System Voltage) |
- |
0 |
|
- |
6.5(No-Load Voltage Ratios) |
- |
0 |
|
- |
6.6(Winding connection and phase displacement) |
- |
0 |
|
- |
6.7(Tapping range and tapping methods) |
- |
0 |
|
- |
6.10(Limits of temperature-rise) |
- |
0 |
|
- |
7("Technical parameters of three phase distribution
transformers higher ") |
- |
0 |
|
- |
8(Technical parameter of single phase distribution transformers) |
- |
0 |
|
- |
9(Standard Materials) |
- |
0 |
|
- |
10(Terminal Arrangement) |
- |
0 |
|
- |
12(Connectors for bare bushing terminations) |
- |
0 |
|
- |
13(Marking) |
- |
0 |
|
- |
15(Trasnformer tank) |
- |
0 |
|
- |
18(Efficiency and regulations) |
- |
0 |
|
- |
19(Tolerances) |
- |
0 |
|
- |
21.1(General) |
- |
0 |
|
- |
21.2(Routine Tests) |
- |
0 |
|
- |
21.3(Types test) |
- |
0 |
|
- |
21.4(Special Test) |
- |
0 |
|
- |
22(Information required with enquiry and order) |
- |
0 |
|
- |
|
Complete
|
|
10 Jun, 2027 |
- Included w.e.f. 28.03.2024. Exclusion: Cl.21.46 (Short-Circuit withstand test (above 200kVA)) |
17 |
Electrical Research and Development Association, gujarat
| IS 1180 : Part 1 (2014) |
Outdoor Type Oil Immersed Distribution Transformers Upto and Including 2 500 kVA, 33kV - Specification Part 1 Mineral Oil Immersed (Fourth Revision) |
DISTRIBUTON TRANSFORMER |
-
|
203805 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
21.2 b)( Measurement of voltage ratio and check of
phase displacemen) |
- |
800 |
|
Test charges for subsequent tap Rs. 400 |
14.1(MOUNTING ARRANGEMENT) |
- |
800 |
|
- |
14.2(MOUNTING ARRANGEMENT) |
- |
800 |
|
- |
14.3(MOUNTING ARRANGEMENT) |
- |
800 |
|
- |
14.4(MOUNTING ARRANGEMENT) |
- |
800 |
|
- |
21.2 a)(Measurement of winding resistance ) |
- |
600 |
|
Test charges for subsequent tap Rs. 300 |
21.2 c)( Measurement of short-circuit impedance
(principal tapping, when applicable) and load
loss at 50 percent and 100 percent load) |
- |
3750 |
|
Test charges for subsequent tap Rs. 2500 |
21.2 d)(Measurement of no-load loss and current) |
- |
2500 |
|
Test charges for subsequent tap Rs. 1250 |
21.2 e)(Measurement of insulation resistance) |
- |
500 |
|
Test charges for subsequent tap Rs. 500 |
21.3(b)(Temperature-rise test) |
- |
15000 |
|
- |
21.2 f)(Induced over-voltage withstand test) |
- |
1000 |
|
Test charges for subsequent tap Rs. 1000 |
21.2 g)( Separate-source voltage withstand test) |
- |
1000 |
|
Test charges for subsequent tap Rs. 1000 |
21.3(c)(Short-circuit withstand test) |
- |
59800 |
|
Test charges may vary as per KVA rating. Given charges upto 250 KVA, 11 KV. |
21.5.1.1(Pressure test-Type test (For Transformers up to 200 kVA
)) |
- |
6000 |
|
- |
21.5.1.2(Pressure test-routine test (For Transformers up to 200 kVA
)) |
- |
6000 |
|
- |
21.5.2.1(Type test : For Transformers Above 200 kVA and Up to Including 2 500 kVA) |
- |
6000 |
|
- |
21.5.2.2(routine test :For Transformers Above 200 kVA and Up to Including 2 500 kVA) |
- |
6000 |
|
- |
21.5.2.3( Oil leakage test (routine test)) |
- |
5000 |
|
- |
21.5.3.1(For Single Phase Distribution Transformers Up to Including 25 kVA : pressure test (type test)) |
- |
6000 |
|
- |
21.5.3.2(For Single Phase Distribution Transformers Up to Including 25 kVA : pressure test (routine test)) |
- |
6000 |
|
- |
21.5.3.3(Oil leakage test (routine test)) |
- |
5000 |
|
- |
15.5(Total Dry Film Paint Thickness) |
- |
3000 |
|
- |
21.4 e(BDV and moisture content of oil in the transformer) |
- |
3000 |
|
- |
21.4 d(Paint adhesion tests) |
- |
3000 |
|
- |
6.9, 7.9, 8.9(Permissible Flux Density and Over Fluxing) |
- |
5000 |
|
- |
21.4 c(No load current at 112.5 percent voltage.) |
- |
1600 |
|
Test charges for subsequent tap Rs. 800 |
11(Minimum clearance in Air) |
- |
1000 |
|
- |
16(Conservator for Non-sealed type Transformers) |
- |
800 |
|
- |
20(Fittings) |
- |
800 |
|
- |
21.3(a )(Lightning impulse test) |
- |
33000 |
|
Charges given for above 250 KVA to 500 KVA. so test charges vary by rating of transformer |
21.4 b(Short-circuit withstand test IS 2026 (Part 5) (above 200 kVA)) |
- |
78200 |
|
- |
21.4 a)( Determination of sound levels) |
- |
2275 |
|
Additional tap - 2275 |
6.8 (50%)(Total losses at 50 % load (Watts)) |
- |
0 |
|
- |
7.8 (50%)(Total losses at 50 % load (Watts)) |
- |
0 |
|
- |
8.8 (50%)(Total losses at 50 % load (Watts)) |
- |
0 |
|
- |
6.8 (100%)(Total losses at 100 % load (Watts)) |
- |
0 |
|
- |
7.8 (100%)(Total losses at 100 % load (Watts)) |
- |
0 |
|
- |
8.8 (100%)(Total losses at 100 % load (Watts)) |
- |
0 |
|
- |
21.5.1.3(Oil leakage test upto 200 KVA) |
- |
5000 |
|
- |
|
Complete
|
|
30 Nov, 2025 |
- - |
18 |
Baroda Calibration Services LLP
| IS 1180 : Part 1 (2014) |
Outdoor Type Oil Immersed Distribution Transformers Upto and Including 2 500 kVA, 33kV - Specification Part 1 Mineral Oil Immersed (Fourth Revision) |
Up to 2500 kVA, 33 kV, oil cooled, 1 Phase & 3 Phase |
-
|
125250 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
21.2 a)(Measurement of winding resistance ) |
- |
500 |
|
Test charges are for one Tap. Test charges for subsequent tap Rs. 400 |
21.2 b)( Measurement of voltage ratio and check of
phase displacemen) |
- |
650 |
|
Test charges are for one Tap. Test charges for subsequent tap Rs. 400 |
21.2 c)( Measurement of short-circuit impedance
(principal tapping, when applicable) and load
loss at 50 percent and 100 percent load) |
- |
3000 |
|
Test charges for subsequent tap Rs. 2200 |
21.2 d)(Measurement of no-load loss and current) |
- |
2100 |
|
Test charges for subsequent tap Rs. 1050 |
21.2 e)(Measurement of insulation resistance) |
- |
475 |
|
Test charges are for one Tap. Test charges for subsequent tap Rs. 475 |
21.2 f)(Induced over-voltage withstand test) |
- |
950 |
|
Test charges are for one Tap. Test charges for subsequent tap Rs. 950. |
21.2 g)( Separate-source voltage withstand test) |
- |
950 |
|
Test charges are for one Tap. Test charges for subsequent tap Rs. 950 |
21.5.3.3(Oil leakage test) |
- |
4250 |
|
- |
21.3(a )(Lightning impulse test) |
- |
30000 |
|
Charges given for above 250 KVA to 1000 KVA. so test charges vary by rating of transformer |
21.3(b)(Temperature-rise test) |
- |
15000 |
|
- |
21.4 c(No load current at 112.5 percent voltage.) |
- |
1400 |
|
Test charges are for one Tap. Test charges for subsequent tap Rs. 700 |
21.4 d(Paint adhesion tests) |
- |
1000 |
|
- |
7.8 (50%)(Total losses at 50 % load (Watts)) |
- |
1200 |
|
- |
7.8 (100%)(Total losses at 100 % load (Watts)) |
- |
1200 |
|
- |
21.5.1.1(Pressure test-Type test (For Transformers up to 200 kVA
)) |
- |
5000 |
|
- |
21.5.1.2(Pressure test-routine test (For Transformers up to 200 kVA
)) |
- |
5000 |
|
- |
21.5.2.1(Type test : For Transformers Above 200 kVA and Up to Including 2 500 kVA) |
- |
5000 |
|
- |
21.5.2.2(routine test :For Transformers Above 200 kVA and Up to Including 2 500 kVA) |
- |
5000 |
|
- |
21.5.3.1(For Single Phase Distribution Transformers Up to Including 25 kVA : pressure test (type test)) |
- |
5000 |
|
- |
21.5.3.2(For Single Phase Distribution Transformers Up to Including 25 kVA : pressure test (routine test)) |
- |
5000 |
|
- |
|
Complete
|
26 Dec, 2023 |
21 Dec, 2026 |
- Exclusion: Cl.21.3(c) (Short-circuit withstand test), Cl.21.4 a) ( Determination of sound levels), Cl.21.4 e (BDV and moisture content of oil in the transformer), Cl.21.4 b (Short-circuit withstand test IS 2026 (Part 5) (above 200 kVA)) |
19 |
ELECTRICAL POWER RESEARCH LABORATORY
| IS 1180 : Part 3 (2021) |
Outdoor/Indoor Type Liquid Immersed Distribution Transformers Up to and Including 2 500 kVA, 33 kV — Specification Part 3 Natural/Synthetic Organic Ester Liquid Immersed |
Outdoor/Indoor Type Liquid Immersed Distribution Transf |
-
|
156750 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
21.2 a(Measurement of winding resistance
[IS 2026 (Part 1)].) |
- |
7050 |
|
Sample rating : 2500 kVA, 17 Tap |
21.2 b(Measurement of voltage ratio and check of phase
displacement [IS 2026 (Part 1)].) |
- |
9650 |
|
Sample rating : 2500 kVA, 17 Tap |
21.2 c(Measurement of short-circuit impedance
(principal tapping, when applicable) and load
loss at 50 percent and 100 percent load
[IS 2026 (Part 1)].) |
- |
7000 |
|
Sample rating : 2500 kVA, 17 Tap |
21.2 d(Measurement of no-load loss and current
[IS 2026 (Part 1)].) |
- |
4500 |
|
Sample rating : 2500 kVA, 17 Tap |
21.2 e(Measurement of insulation resistance
[IS 2026 (Part 1)].) |
- |
550 |
|
Sample rating : 2500 kVA, 17 Tap |
21.2 f(Induced over-voltage withstand test
[IS 2026 (Part 3)].) |
- |
1000 |
|
Sample rating : 2500 kVA, 17 Tap |
21.2 g(Separate-source voltage withstand test
[IS 2026 (Part 3)]) |
- |
1000 |
|
Sample rating : 2500 kVA, 17 Tap |
21.3 a(Lightning impulse test [IS 2026 (Part 3)].) |
- |
75000 |
|
Sample rating : 2500 kVA, 17 Tap with chopping |
21.3 b(Temperature-rise test [IS 2026 (Part 2)].) |
- |
20000 |
|
Sample rating : 2500 kVA, 17 Tap |
21.3 d(Pressure test) |
- |
9000 |
|
Sample rating : 2500 kVA, 17 Tap |
21.4 a(Determination of sound levels [IS 2026 (Part 10)];) |
- |
5000 |
|
Sample rating : 2500 kVA, 17 Tap |
21.4 c(No load current at 112.5 percent voltage
(see 6.9.2, 7.9.2, 8.9.2);) |
- |
1500 |
|
Sample rating : 2500 kVA, 17 Tap |
21.4 d(Paint adhesion test — The test is performed as
per ASTM D3359 (Standard Test Methods for
measuring adhesion by tape test).) |
- |
1000 |
|
Sample rating : 2500 kVA, 17 Tap |
21.4 e(BDV and Moisture content of liquid in the
transformer (IS 16081, IS 16099, IS 16899 or
IS 16659, whichever is applicable).) |
- |
5000 |
|
Sample rating : 2500 kVA, 17 Tap |
21.5(Pressure and Ester Liquid Leakage Test) |
- |
9500 |
|
Sample rating : 2500 kVA, 17 Tap
Pressure (Routine): 5000 and Leakage test : 4500 |
|
Complete
|
|
26 Aug, 2027 |
- Exclusion: 21.3 c (Short-circuit withstand test [IS 2026 (Part 5)] (up to 200 kVA) and) , Cl.21.4 b (Short-circuit withstand test [IS 2026 (Part 5)] (above 200 kVA);) |
20 |
ELECTRICAL POWER RESEARCH LABORATORY
| IS 1180 : Part 1 (2014) |
Outdoor Type Oil Immersed Distribution Transformers Upto and Including 2 500 kVA, 33kV - Specification Part 1 Mineral Oil Immersed (Fourth Revision) |
Outdoor Type Oil Immersed Distribution Transformers up |
-
|
156750 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
21.2 a)(Measurement of winding resistance ) |
- |
7050 |
|
Rating of sample 2500 kVA, 17 Tap |
21.2 b)( Measurement of voltage ratio and check of
phase displacemen) |
- |
9650 |
|
Rating of sample 2500 kVA, 17 Tap |
21.2 c)( Measurement of short-circuit impedance
(principal tapping, when applicable) and load
loss at 50 percent and 100 percent load) |
- |
7000 |
|
Rating of sample 2500 kVA, 17 Tap |
21.2 d)(Measurement of no-load loss and current) |
- |
4500 |
|
Rating of sample 2500 kVA, 17 Tap |
21.2 e)(Measurement of insulation resistance) |
- |
550 |
|
Rating of sample 2500 kVA, 17 Tap |
21.2 f)(Induced over-voltage withstand test) |
- |
1000 |
|
Rating of sample 2500 kVA, 17 Tap |
21.2 g)( Separate-source voltage withstand test) |
- |
1000 |
|
Rating of sample 2500 kVA, 17 Tap |
21.3(a )(Lightning impulse test) |
- |
75000 |
|
Rating of sample 2500 kVA, 17 Tap with chopping |
21.3(b)(Temperature-rise test) |
- |
20000 |
|
Rating of sample 2500 kVA, 17 Tap |
21.4 a)( Determination of sound levels) |
- |
5000 |
|
Rating of sample 2500 kVA, 17 Tap |
21.5.2.1(Type test : For Transformers Above 200 kVA and Up to Including 2 500 kVA) |
- |
9000 |
|
Rating of sample 2500 kVA, 17 Tap |
21.5.2.2(routine test :For Transformers Above 200 kVA and Up to Including 2 500 kVA) |
- |
5000 |
|
Rating of sample 2500 kVA, 17 Tap |
21.5.2.3( Oil leakage test (routine test)) |
- |
4500 |
|
Rating of sample 2500 kVA, 17 Tap |
21.4 c(No load current at 112.5 percent voltage.) |
- |
1500 |
|
Rating of sample 2500 kVA, 17 Tap |
21.4 d(Paint adhesion tests) |
- |
1000 |
|
Rating of sample 2500 kVA, 17 Tap |
21.4 e(BDV and moisture content of oil in the transformer) |
- |
5000 |
|
Rating of sample 2500 kVA, 17 Tap |
|
Complete
|
|
26 Aug, 2027 |
- Exclusion: Cl.21.3(c) (Short-circuit withstand test), Cl.21.4 b (Short-circuit withstand test) |
21 |
CENTRAL POWER RESEARCH INSTITUTE NOIDA
| IS 1180 : Part 1 (2014) |
Outdoor Type Oil Immersed Distribution Transformers Upto and Including 2 500 kVA, 33kV - Specification Part 1 Mineral Oil Immersed (Fourth Revision) |
- |
-
|
212050 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
21.2 a)(Measurement of winding resistance ) |
- |
6000 |
|
- |
21.2 b)( Measurement of voltage ratio and check of
phase displacemen) |
- |
3000 |
|
- |
21.2 c)( Measurement of short-circuit impedance
(principal tapping, when applicable) and load
loss at 50 percent and 100 percent load) |
- |
11820 |
|
- |
21.2 d)(Measurement of no-load loss and current) |
- |
1000 |
|
- |
21.2 e)(Measurement of insulation resistance) |
- |
3000 |
|
- |
21.2 f)(Induced over-voltage withstand test) |
- |
3710 |
|
- |
21.2 g)( Separate-source voltage withstand test) |
- |
2000 |
|
- |
21.5.3.3(Oil leakage test) |
- |
6380 |
|
- |
21.3(a )(Lightning impulse test) |
- |
77980 |
|
- |
21.3(b)(Temperature-rise test) |
- |
33810 |
|
- |
21.4 a)( Determination of sound levels) |
- |
33350 |
|
- |
21.5.1.1(Pressure test-Type test (For Transformers up to 200 kVA
)) |
- |
12760 |
|
- |
21.5.1.2(Pressure test-routine test (For Transformers up to 200 kVA
)) |
- |
6380 |
|
- |
21.5.2.3( Oil leakage test (routine test)) |
- |
6380 |
|
- |
21.4 c(No load current at 112.5 percent voltage.) |
- |
1000 |
|
- |
21.4 e(BDV and moisture content of oil in the transformer) |
- |
3480 |
|
- |
13.1(Marking (Rating Plates)) |
- |
0 |
|
- |
13.2(Terminal Marking Plate) |
- |
0 |
|
- |
13.3(Marking ) |
- |
0 |
|
- |
13.4(Marking) |
- |
0 |
|
- |
13.4.1(Marking) |
- |
0 |
|
- |
21.4 d(Paint adhesion tests) |
- |
0 |
|
- |
14.1(MOUNTING ARRANGEMENT) |
- |
0 |
|
- |
14.2(MOUNTING ARRANGEMENT) |
- |
0 |
|
- |
14.3(MOUNTING ARRANGEMENT) |
- |
0 |
|
- |
14.4(MOUNTING ARRANGEMENT) |
- |
0 |
|
- |
15.1.1(TRANSFORMER TANK : Construction) |
- |
0 |
|
- |
15.1.2(TRANSFORMER TANK : Construction) |
- |
0 |
|
- |
15.1.3(TRANSFORMER TANK : Construction) |
- |
0 |
|
- |
15.1.4(TRANSFORMER TANK : Construction) |
- |
0 |
|
- |
15.1.5(TRANSFORMER TANK : Construction) |
- |
0 |
|
- |
21.5.2.1(Type test : For Transformers Above 200 kVA and Up to Including 2 500 kVA) |
- |
0 |
|
INCLUSIVE |
21.5.2.2(routine test :For Transformers Above 200 kVA and Up to Including 2 500 kVA) |
- |
0 |
|
INCLUSIVE |
21.5.3.1(For Single Phase Distribution Transformers Up to Including 25 kVA : pressure test (type test)) |
- |
0 |
|
INCLUSIVE |
21.5.3.2(For Single Phase Distribution Transformers Up to Including 25 kVA : pressure test (routine test)) |
- |
0 |
|
INCLUSIVE |
21.5.3.3(Oil leakage test (routine test)) |
- |
0 |
|
INCLUSIVE |
15.5(Total Dry Film Paint Thickness) |
- |
0 |
|
- |
6.9, 7.9, 8.9(Permissible Flux Density and Over Fluxing) |
- |
0 |
|
- |
11(Minimum clearance in Air) |
- |
0 |
|
- |
16(Conservator for Non-sealed type Transformers) |
- |
0 |
|
- |
20(Fittings) |
- |
0 |
|
- |
6.8 (50%)(Total losses at 50 % load (Watts)) |
- |
17820 |
|
- |
7.8 (50%)(Total losses at 50 % load (Watts)) |
- |
0 |
|
INCLUSIVE |
8.8 (50%)(Total losses at 50 % load (Watts)) |
- |
0 |
|
INCLUSIVE |
6.8 (100%)(Total losses at 100 % load (Watts)) |
- |
17820 |
|
- |
7.8 (100%)(Total losses at 100 % load (Watts)) |
- |
0 |
|
INCLUSIVE |
8.8 (100%)(Total losses at 100 % load (Watts)) |
- |
0 |
|
INCLUSIVE |
21.5.1.3(Oil leakage test upto 200 KVA) |
- |
0 |
|
INCLUSIVE |
9.1a)(CRGO Electrical Steel) |
- |
0 |
|
- |
9.1 b)(Amorphous core material) |
- |
0 |
|
- |
9.1 c)(Copper/Aluminium conductor) |
- |
0 |
|
- |
9.1 d)(Kraft paper) |
- |
0 |
|
- |
9.1 e)(Press Board) |
- |
0 |
|
- |
9.1 f)(Mineral oil) |
- |
0 |
|
- |
10(Terminal Arrangement) |
- |
0 |
|
- |
15.2(Pressure and Vacuum Requirements) |
- |
0 |
|
- |
15.4(Gasket) |
- |
0 |
|
- |
19(Tolerances) |
- |
0 |
|
- |
18(Efficiency and regulation) |
- |
0 |
|
- |
4(Service Conditions) |
- |
0 |
|
- |
5(General ) |
- |
0 |
|
- |
6.1(Rating) |
- |
0 |
|
- |
6.2(Rated frequency) |
- |
0 |
|
- |
6.3(Nominal system voltage) |
- |
0 |
|
- |
6.4(Basic Insulation level ) |
- |
0 |
|
- |
6.5(No-Load Voltage Ratios) |
- |
0 |
|
- |
6.6(Winding connections and phase displacement) |
- |
0 |
|
- |
6.7(Tapping Range and Tapping Method) |
- |
0 |
|
- |
6.8(Losses and impedance values) |
- |
0 |
|
- |
6.9(Permissible Flux Density and Over Fluxing ) |
- |
0 |
|
- |
6.1(Limits of Temperature-rise) |
- |
0 |
|
- |
7(Technical Parameters of three phase distribution trasnformers
higher than 200kva) |
- |
0 |
|
- |
8(Technical Parameters of single phase distribution transformers
UP to and including 25 KVA ) |
- |
0 |
|
- |
9(Standard Materials) |
- |
0 |
|
- |
10(Terminal arrangment ) |
- |
0 |
|
- |
11(Minimum Clearnaces air ) |
- |
0 |
|
- |
12(Connectors ) |
- |
0 |
|
- |
13(Marking ) |
- |
0 |
|
- |
14(Mounting arrangement) |
- |
0 |
|
- |
15(Trasnformer Tank ) |
- |
0 |
|
- |
16(Conservator for Non-Sealed type Transformers) |
- |
0 |
|
- |
18(Efficiency and Regulation) |
- |
0 |
|
- |
19(Tolerances) |
- |
0 |
|
- |
20(Fittings) |
- |
0 |
|
- |
21(General ) |
- |
0 |
|
- |
22(Information required with enquiry and order ) |
- |
0 |
|
- |
|
Complete
|
|
25 Mar, 2027 |
- Exclusion: Cl.21.3(c) (Short-circuit withstand test), Cl. 17 ( ABILITY OF TRANSFORMERS TO WITHSTAND EXTERNAL SHORT CIRCUIT), Cl. 21.4 b (Short-circuit withstand test IS 2026 (Part 5) (above 200 kVA)) |
22 |
Electrical Research and Development Association
| IS 1180 : Part 1 (2014) |
Outdoor Type Oil Immersed Distribution Transformers Upto and Including 2 500 kVA, 33kV - Specification Part 1 Mineral Oil Immersed (Fourth Revision) |
Distribution Transformer |
-
|
115725 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
21.2 a)(Measurement of winding resistance ) |
- |
690 |
|
Testing charges Measurement of winding resistance is Rs.690, Subsequent measurement at different taps is Rs.345 |
21.2 b)( Measurement of voltage ratio and check of
phase displacemen) |
- |
920 |
|
Testing charges for Measurement of winding resistance is Rs.920, Subsequent measurement at different taps is Rs.460 |
21.2 c)( Measurement of short-circuit impedance
(principal tapping, when applicable) and load
loss at 50 percent and 100 percent load) |
- |
4313 |
|
Testing charges for short circuit impedance |
21.2 d)(Measurement of no-load loss and current) |
- |
2875 |
|
Testing charges for no load loss and current |
21.2 e)(Measurement of insulation resistance) |
- |
575 |
|
Testing charges for measurement of insulation resistance |
21.2 f)(Induced over-voltage withstand test) |
- |
1150 |
|
Testing charges for induced over voltage withstand test |
21.2 g)( Separate-source voltage withstand test) |
- |
1150 |
|
Testing charges for separate source voltage withstand test |
21.3(a )(Lightning impulse test) |
- |
31762 |
|
Testing charges for lightening impulse test up to 100kVA is Rs.28875, from 100kVA up to 200kVA is Rs.31762 |
21.3(b)(Temperature-rise test) |
- |
17250 |
|
Testing charges for temperature rise test |
21.4 a)( Determination of sound levels) |
- |
2620 |
|
Testing charges for determination of sound levels |
21.5.1.1(Pressure test-Type test (For Transformers up to 200 kVA
)) |
- |
10000 |
|
Testing charges up to 100kVA is Rs.10000, from 100kVA up to 200kVA is Rs.6000 |
21.5.1.2(Pressure test-routine test (For Transformers up to 200 kVA
)) |
- |
5000 |
|
Testing charges up to 100kVA is Rs.5000, from 100kVA and up to 200kVA is Rs.3000 |
21.5.3.1(For Single Phase Distribution Transformers Up to Including 25 kVA : pressure test (type test)) |
- |
6000 |
|
Testing charges for pressure test( type test) |
21.5.3.2(For Single Phase Distribution Transformers Up to Including 25 kVA : pressure test (routine test)) |
- |
3000 |
|
Testing charges for pressure test ( routine test) |
21.5.3.3(Oil leakage test (routine test)) |
- |
5000 |
|
Testing charges for oil leakage test ( routine test) |
13.1(Marking (Rating Plates)) |
- |
1000 |
|
Testing charges for Marking ( Rating plates) |
13.2(Terminal Marking Plate) |
- |
1000 |
|
Testing charges for Terminal Marking Plate |
13.3(Marking ) |
- |
1000 |
|
Testing charges for Marking |
13.4(Marking) |
- |
1000 |
|
Testing charges for Marking |
13.4.1(Marking) |
- |
1000 |
|
Testing charges for Marking |
14.1(MOUNTING ARRANGEMENT) |
- |
1000 |
|
Testing charges for Mounting arrangement |
14.4(MOUNTING ARRANGEMENT) |
- |
1000 |
|
Testing charges for Mounting arrangement |
15.1.1(TRANSFORMER TANK : Construction) |
- |
800 |
|
Testing charges for Transformer tank : construction |
15.1.2(TRANSFORMER TANK : Construction) |
- |
800 |
|
Testing charges for Transformer tank : construction |
15.1.3(TRANSFORMER TANK : Construction) |
- |
800 |
|
Testing charges for Transformer tank : construction |
15.1.4(TRANSFORMER TANK : Construction) |
- |
800 |
|
Testing charges for Transformer tank : construction |
15.1.5(TRANSFORMER TANK : Construction) |
- |
800 |
|
Testing charges for Transformer tank : construction |
21.4 e(BDV and moisture content of oil in the transformer) |
- |
1990 |
|
Testing charges for BDV and moisture content of oil in the transformer |
21.4 d(Paint adhesion tests) |
- |
4830 |
|
Testing charges for Paint adhesion tests |
21.4 c(No load current at 112.5 percent voltage.) |
- |
1600 |
|
Testing charges for No load current at 112.5 percent voltage |
11(Minimum clearance in Air) |
- |
1000 |
|
Testing charges for Minimum clearance in Air |
16(Conservator for Non-sealed type Transformers) |
- |
1000 |
|
Testing charges for Conservator for Non-sealed type Transformers |
20(Fittings) |
- |
2000 |
|
Testing charges for Fittings (Standard Fitting 1000/- & Optional Fitting 1000/-) |
|
Complete
|
|
22 Dec, 2024 |
- upto 200 KVA with
subcontracting to M/s
ERDA, Vadodara for
Short Circuit Withstand
Test (Cl. 21.3 (c)) till 13
Feb 2019. |
23 |
Central Power Research Institute (CPRI), Bangalore
| IS 1180 : Part 1 (2014) |
Outdoor Type Oil Immersed Distribution Transformers Upto and Including 2 500 kVA, 33kV - Specification Part 1 Mineral Oil Immersed (Fourth Revision) |
- |
-
|
274000 View breakup
Complete testing charges:
Rs. 315100/- per transformer (up to 200 kVA without taps);
Rs. 365010/- per transformer (up to 200 kVA with 7 taps);
Rs. 365010/- per transformer ( above 200 kVA & up to 250 kVA with 7 taps);
Rs. 405260/- per transformer (above 250 kVA & up to 500 kVA with 7 taps);
Rs. 408840/- per transformer (1600 kVA & up to 2000 kVA with 7 taps excluding short circuit test); Rs. 443340/- per transformer (2000 kVA & up to 2500 kVA with 7 taps excluding short circuit test); Rs. 275260/- per transformer (500 kVA & up to 630 kVA with 17 taps excluding short circuit test); Rs. 284230/- per transformer (630 kVA & up to 1000 kVA with 17 taps excluding short circuit test); Rs. 399640/- per transformer (1000 kVA & up to 1600 kVA with 17 taps excluding short circuit test).
Test charges will vary depending on the rating of the sample. The applicable test charges will be intimated through a proforma invoice.
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
21.2 a)(Measurement of winding resistance ) |
- |
5100 |
|
Test charges will vary depending on the kVA & Tappings of the Transformer
Test charge applicable will be intimated through a proforma invoice |
21.2 b)( Measurement of voltage ratio and check of
phase displacemen) |
- |
3400 |
|
Test charges will vary depending on the kVA & Tappings of the Transformer
Test charge applicable will be intimated through a proforma invoice |
21.2 c)( Measurement of short-circuit impedance
(principal tapping, when applicable) and load
loss at 50 percent and 100 percent load) |
- |
10150 |
|
Test charges will vary depending on the kVA & Tappings of the Transformer
Test charge applicable will be intimated through a proforma invoice |
21.2 d)(Measurement of no-load loss and current) |
- |
10150 |
|
Test charges will vary depending on the kVA & Tappings of the Transformer
Test charge applicable will be intimated through a proforma invoice |
21.2 e)(Measurement of insulation resistance) |
- |
2550 |
|
Test charges will vary depending on the kVA & Tappings of the Transformer
Test charge applicable will be intimated through a proforma invoice |
21.2 f)(Induced over-voltage withstand test) |
- |
3200 |
|
Test charges will vary depending on the kVA & Tappings of the Transformer
Test charge applicable will be intimated through a proforma invoice |
21.2 g)( Separate-source voltage withstand test) |
- |
5200 |
|
Test charges will vary depending on the kVA & Tappings of the Transformer
Test charge applicable will be intimated through a proforma invoice |
21.3(b)(Temperature-rise test) |
- |
41600 |
|
Test charges will vary depending on the kVA & Tappings of the Transformer
Test charge applicable will be intimated through a proforma invoice |
21.3(c)(Short-circuit withstand test) |
- |
84450 |
|
Test charges will vary depending on the kVA & Tappings of the Transformer
Test charge applicable will be intimated through a proforma invoice |
21.4 c(No load current at 112.5 percent voltage.) |
- |
1700 |
|
Test charges will vary depending on the kVA & Tappings of the Transformer
Test charge applicable will be intimated through a proforma invoice |
21.5.1.1(Pressure test-Type test (For Transformers up to 200 kVA
)) |
- |
11000 |
|
Test charges will vary depending on the kVA & Tappings of the Transformer
Test charge applicable will be intimated through a proforma invoice |
21.5.1.2(Pressure test-routine test (For Transformers up to 200 kVA
)) |
- |
11000 |
|
Test charges will vary depending on the kVA & Tappings of the Transformer
Test charge applicable will be intimated through a proforma invoice |
21.5.2.1(Type test : For Transformers Above 200 kVA and Up to Including 2 500 kVA) |
- |
11000 |
|
Test charges will vary depending on the kVA & Tappings of the Transformer
Test charge applicable will be intimated through a proforma invoice |
21.5.2.2(routine test :For Transformers Above 200 kVA and Up to Including 2 500 kVA) |
- |
11000 |
|
Test charges will vary depending on the kVA & Tappings of the Transformer
Test charge applicable will be intimated through a proforma invoice |
21.5.2.3( Oil leakage test (routine test)) |
- |
5500 |
|
Test charges will vary depending on the kVA & Tappings of the Transformer
Test charge applicable will be intimated through a proforma invoice |
21.5.3.3(Oil leakage test (routine test)) |
- |
5500 |
|
Test charges will vary depending on the kVA & Tappings of the Transformer
Test charge applicable will be intimated through a proforma invoice |
21.5.3.1(For Single Phase Distribution Transformers Up to Including 25 kVA : pressure test (type test)) |
- |
11000 |
|
Test charges will vary depending on the kVA & Tappings of the Transformer
Test charge applicable will be intimated through a proforma invoice |
21.5.3.2(For Single Phase Distribution Transformers Up to Including 25 kVA : pressure test (routine test)) |
- |
11000 |
|
Test charges will vary depending on the kVA & Tappings of the Transformer
Test charge applicable will be intimated through a proforma invoice |
21.4 d(Paint adhesion tests) |
- |
2400 |
|
Test charges will vary depending on the kVA & Tappings of the Transformer
Test charge applicable will be intimated through a proforma invoice |
21.4 a)( Determination of sound levels) |
- |
28800 |
|
Test charges will vary depending on the kVA & Tappings of the Transformer
Test charge applicable will be intimated through a proforma invoice |
21.4 e(BDV and moisture content of oil in the transformer) |
- |
3000 |
|
Test charges will vary depending on the kVA & Tappings of the Transformer
Test charge applicable will be intimated through a proforma invoice |
21.3(a )(Lightning impulse test) |
- |
58300 |
|
Test charges will vary depending on the kVA & Tappings of the Transformer
Test charge applicable will be intimated through a proforma invoice |
21.5.1.3(Oil leakage test upto 200 KVA) |
- |
5500 |
|
Test charges will vary depending on the kVA & Tappings of the Transformer
Test charge applicable will be intimated through a proforma invoice |
|
Complete
|
|
31 Dec, 2026 |
- - |
24 |
Rajasthan Test & Research Centre
| IS 1180 : Part 1 (2014) |
Outdoor Type Oil Immersed Distribution Transformers Upto and Including 2 500 kVA, 33kV - Specification Part 1 Mineral Oil Immersed (Fourth Revision) |
- |
-
|
122000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
13.1(Marking (Rating Plates)) |
- |
300 |
|
Charges for 33kV , 2500 kVA, 3-Phase Distribution Transformers. |
13.2(Terminal Marking Plate) |
- |
300 |
|
Charges for 33kV , 2500 kVA, 3-Phase Distribution Transformers. |
13.3(Marking ) |
- |
300 |
|
Charges for 33kV , 2500 kVA, 3-Phase Distribution Transformers. |
13.4(Marking) |
- |
300 |
|
Charges for 33kV , 2500 kVA, 3-Phase Distribution Transformers. |
13.4.1(Marking) |
- |
300 |
|
Charges for 33kV , 2500 kVA, 3-Phase Distribution Transformers. |
14.1(MOUNTING ARRANGEMENT) |
- |
500 |
|
Charges for 33kV , 2500 kVA, 3-Phase Distribution Transformers. |
14.2(MOUNTING ARRANGEMENT) |
- |
500 |
|
Charges for 33kV , 2500 kVA, 3-Phase Distribution Transformers. |
14.3(MOUNTING ARRANGEMENT) |
- |
500 |
|
Charges for 33kV , 2500 kVA, 3-Phase Distribution Transformers. |
14.4(MOUNTING ARRANGEMENT) |
- |
500 |
|
Charges for 33kV , 2500 kVA, 3-Phase Distribution Transformers. |
15.1.1(TRANSFORMER TANK : Construction) |
- |
1000 |
|
Charges for 33kV , 2500 kVA, 3-Phase Distribution Transformers. |
15.1.2(TRANSFORMER TANK : Construction) |
- |
1000 |
|
Charges for 33kV , 2500 kVA, 3-Phase Distribution Transformers. |
15.1.3(TRANSFORMER TANK : Construction) |
- |
1000 |
|
Charges for 33kV , 2500 kVA, 3-Phase Distribution Transformers. |
15.1.4(TRANSFORMER TANK : Construction) |
- |
1000 |
|
Charges for 33kV , 2500 kVA, 3-Phase Distribution Transformers. |
15.1.5(TRANSFORMER TANK : Construction) |
- |
1000 |
|
Charges for 33kV , 2500 kVA, 3-Phase Distribution Transformers. |
21.2 a)(Measurement of winding resistance ) |
- |
750 |
|
Charges for 33kV , 2500 kVA, 3-Phase Distribution Transformers.
Charges 750 Rs Applicable for each Tap. |
21.2 b)( Measurement of voltage ratio and check of
phase displacemen) |
- |
650 |
|
Charges for 33kV , 2500 kVA, 3-Phase Distribution Transformers.
Charges 650 Rs Applicable for each Tap. |
21.2 c)( Measurement of short-circuit impedance
(principal tapping, when applicable) and load
loss at 50 percent and 100 percent load) |
- |
950 |
|
Charges for 33kV , 2500 kVA, 3-Phase Distribution Transformers.
Charges 950 Rs Applicable for each Tap. |
21.2 d)(Measurement of no-load loss and current) |
- |
2000 |
|
Charges for 33kV , 2500 kVA, 3-Phase Distribution Transformers. |
21.2 e)(Measurement of insulation resistance) |
- |
1500 |
|
Charges for 33kV , 2500 kVA, 3-Phase Distribution Transformers. |
21.2 f)(Induced over-voltage withstand test) |
- |
3500 |
|
Charges for 33kV , 2500 kVA, 3-Phase Distribution Transformers. |
21.2 g)( Separate-source voltage withstand test) |
- |
3500 |
|
Charges for 33kV , 2500 kVA, 3-Phase Distribution Transformers. |
21.5.3.3(Oil leakage test) |
- |
6000 |
|
Charges for 33kV , 2500 kVA, 3-Phase Distribution Transformers. |
21.4 c(No load current at 112.5 percent voltage.) |
- |
1500 |
|
Charges for 33kV , 2500 kVA, 3-Phase Distribution Transformers. |
21.4 d(Paint adhesion tests) |
- |
1200 |
|
Charges for 33kV , 2500 kVA, 3-Phase Distribution Transformers. |
21.4 e(BDV and moisture content of oil in the transformer) |
- |
1500 |
|
Charges for 33kV , 2500 kVA, 3-Phase Distribution Transformers. |
6.9, 7.9, 8.9(Permissible Flux Density and Over Fluxing) |
- |
6300 |
|
Charges for 33kV , 2500 kVA, 3-Phase Distribution Transformers. |
11(Minimum clearance in Air) |
- |
1050 |
|
Charges for 33kV , 2500 kVA, 3-Phase Distribution Transformers. |
16(Conservator for Non-sealed type Transformers) |
- |
500 |
|
Charges for 33kV , 2500 kVA, 3-Phase Distribution Transformers. |
20(Fittings) |
- |
500 |
|
Charges for 33kV , 2500 kVA, 3-Phase Distribution Transformers. |
6.8 (50%)(Total losses at 50 % load (Watts)) |
- |
1250 |
|
Charges for 33kV , 2500 kVA, 3-Phase Distribution Transformers. |
7.8 (50%)(Total losses at 50 % load (Watts)) |
- |
1750 |
|
Charges for 33kV , 2500 kVA, 3-Phase Distribution Transformers. |
8.8 (50%)(Total losses at 50 % load (Watts)) |
- |
1000 |
|
Charges for 33kV , 2500 kVA, 3-Phase Distribution Transformers. |
6.8 (100%)(Total losses at 100 % load (Watts)) |
- |
1500 |
|
Charges for 33kV , 2500 kVA, 3-Phase Distribution Transformers. |
7.8 (100%)(Total losses at 100 % load (Watts)) |
- |
2000 |
|
Charges for 33kV , 2500 kVA, 3-Phase Distribution Transformers. |
8.8 (100%)(Total losses at 100 % load (Watts)) |
- |
1250 |
|
Charges for 33kV , 2500 kVA, 3-Phase Distribution Transformers. |
21.5.1.3(Oil leakage test upto 200 KVA) |
- |
4500 |
|
Charges for 33kV , 200 kVA, 3-Phase Distribution Transformers. |
21.5.3.1(For Single Phase Distribution Transformers Up to Including 25 kVA : pressure test (type test)) |
- |
2700 |
|
- |
21.5.3.2(For Single Phase Distribution Transformers Up to Including 25 kVA : pressure test (routine test)) |
- |
5000 |
|
- |
21.5.1.1(Pressure test-Type test (For Transformers up to 200 kVA
)) |
- |
3000 |
|
- |
21.5.1.2(Pressure test-routine test (For Transformers up to 200 kVA
)) |
- |
5000 |
|
- |
21.3(a )(Lightning impulse test) |
- |
35700 |
|
- |
21.3(b)(Temperature-rise test) |
- |
23500 |
|
- |
21.4 a)( Determination of sound levels) |
- |
6000 |
|
- |
|
Complete
|
|
16 Aug, 2024 |
- - |
25 |
Central Power Research Institute (CPRI), Bangalore
| IS 1180 : Part 1 (2014) |
Outdoor Type Oil Immersed Distribution Transformers Upto and Including 2 500 kVA, 33kV - Specification Part 1 Mineral Oil Immersed (Fourth Revision) |
- |
-
|
274000 View breakup
Complete testing charges:
Rs. 315100/- per transformer (up to 200 kVA without taps);
Rs. 365010/- per transformer (up to 200 kVA with 7 taps);
Rs. 365010/- per transformer ( above 200 kVA & up to 250 kVA with 7 taps);
Rs. 405260/- per transformer (above 250 kVA & up to 500 kVA with 7 taps);
Rs. 408840/- per transformer (1600 kVA & up to 2000 kVA with 7 taps excluding short circuit test); Rs. 443340/- per transformer (2000 kVA & up to 2500 kVA with 7 taps excluding short circuit test); Rs. 275260/- per transformer (500 kVA & up to 630 kVA with 17 taps excluding short circuit test); Rs. 284230/- per transformer (630 kVA & up to 1000 kVA with 17 taps excluding short circuit test); Rs. 399640/- per transformer (1000 kVA & up to 1600 kVA with 17 taps excluding short circuit test).
Test charges will vary depending on the rating of the sample. The applicable test charges will be intimated through a proforma invoice.
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
21.2 a)(Measurement of winding resistance ) |
- |
5100 |
|
Test charges will vary depending on the kVA & Tappings of the Transformer
Test charge applicable will be intimated through a proforma invoice |
21.2 b)( Measurement of voltage ratio and check of
phase displacemen) |
- |
3400 |
|
Test charges will vary depending on the kVA & Tappings of the Transformer
Test charge applicable will be intimated through a proforma invoice |
21.2 c)( Measurement of short-circuit impedance
(principal tapping, when applicable) and load
loss at 50 percent and 100 percent load) |
- |
10150 |
|
Test charges will vary depending on the kVA & Tappings of the Transformer
Test charge applicable will be intimated through a proforma invoice |
21.2 d)(Measurement of no-load loss and current) |
- |
10150 |
|
Test charges will vary depending on the kVA & Tappings of the Transformer
Test charge applicable will be intimated through a proforma invoice |
21.2 e)(Measurement of insulation resistance) |
- |
2550 |
|
Test charges will vary depending on the kVA & Tappings of the Transformer
Test charge applicable will be intimated through a proforma invoice |
21.2 f)(Induced over-voltage withstand test) |
- |
3200 |
|
Test charges will vary depending on the kVA & Tappings of the Transformer
Test charge applicable will be intimated through a proforma invoice |
21.2 g)( Separate-source voltage withstand test) |
- |
5200 |
|
Test charges will vary depending on the kVA & Tappings of the Transformer
Test charge applicable will be intimated through a proforma invoice |
21.3(b)(Temperature-rise test) |
- |
41600 |
|
Test charges will vary depending on the kVA & Tappings of the Transformer
Test charge applicable will be intimated through a proforma invoice |
21.3(c)(Short-circuit withstand test) |
- |
84450 |
|
Test charges will vary depending on the kVA & Tappings of the Transformer
Test charge applicable will be intimated through a proforma invoice |
21.4 c(No load current at 112.5 percent voltage.) |
- |
1700 |
|
Test charges will vary depending on the kVA & Tappings of the Transformer
Test charge applicable will be intimated through a proforma invoice |
21.5.1.1(Pressure test-Type test (For Transformers up to 200 kVA
)) |
- |
11000 |
|
Test charges will vary depending on the kVA & Tappings of the Transformer
Test charge applicable will be intimated through a proforma invoice |
21.5.1.2(Pressure test-routine test (For Transformers up to 200 kVA
)) |
- |
11000 |
|
Test charges will vary depending on the kVA & Tappings of the Transformer
Test charge applicable will be intimated through a proforma invoice |
21.5.2.1(Type test : For Transformers Above 200 kVA and Up to Including 2 500 kVA) |
- |
11000 |
|
Test charges will vary depending on the kVA & Tappings of the Transformer
Test charge applicable will be intimated through a proforma invoice |
21.5.2.2(routine test :For Transformers Above 200 kVA and Up to Including 2 500 kVA) |
- |
11000 |
|
Test charges will vary depending on the kVA & Tappings of the Transformer
Test charge applicable will be intimated through a proforma invoice |
21.5.2.3( Oil leakage test (routine test)) |
- |
5500 |
|
Test charges will vary depending on the kVA & Tappings of the Transformer
Test charge applicable will be intimated through a proforma invoice |
21.5.3.3(Oil leakage test (routine test)) |
- |
5500 |
|
Test charges will vary depending on the kVA & Tappings of the Transformer
Test charge applicable will be intimated through a proforma invoice |
21.5.3.1(For Single Phase Distribution Transformers Up to Including 25 kVA : pressure test (type test)) |
- |
11000 |
|
Test charges will vary depending on the kVA & Tappings of the Transformer
Test charge applicable will be intimated through a proforma invoice |
21.5.3.2(For Single Phase Distribution Transformers Up to Including 25 kVA : pressure test (routine test)) |
- |
11000 |
|
Test charges will vary depending on the kVA & Tappings of the Transformer
Test charge applicable will be intimated through a proforma invoice |
21.4 d(Paint adhesion tests) |
- |
2400 |
|
Test charges will vary depending on the kVA & Tappings of the Transformer
Test charge applicable will be intimated through a proforma invoice |
21.4 a)( Determination of sound levels) |
- |
28800 |
|
Test charges will vary depending on the kVA & Tappings of the Transformer
Test charge applicable will be intimated through a proforma invoice |
21.4 e(BDV and moisture content of oil in the transformer) |
- |
3000 |
|
Test charges will vary depending on the kVA & Tappings of the Transformer
Test charge applicable will be intimated through a proforma invoice |
21.3(a )(Lightning impulse test) |
- |
58300 |
|
Test charges will vary depending on the kVA & Tappings of the Transformer
Test charge applicable will be intimated through a proforma invoice |
|
Complete
|
|
31 Dec, 2026 |
- - |
26 |
Vijai Electricals Ltd., Transformer Testing Laboratory
| IS 1180 : Part 1 (2014) |
Outdoor Type Oil Immersed Distribution Transformers Upto and Including 2 500 kVA, 33kV - Specification Part 1 Mineral Oil Immersed (Fourth Revision) |
Distribution Transformer upto 2500kVA & 33kV Class |
-
|
120000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
21.2 a)(Measurement of winding resistance ) |
- |
600 |
|
For 100kVA |
21.2 b)( Measurement of voltage ratio and check of
phase displacemen) |
- |
800 |
|
For 100kVA |
21.2 c)( Measurement of short-circuit impedance
(principal tapping, when applicable) and load
loss at 50 percent and 100 percent load) |
- |
2500 |
|
For 100kVA |
21.2 d)(Measurement of no-load loss and current) |
- |
1600 |
|
For 100kVA |
21.2 e)(Measurement of insulation resistance) |
- |
500 |
|
For 100kVA |
21.2 f)(Induced over-voltage withstand test) |
- |
1000 |
|
For 100kVA |
21.2 g)( Separate-source voltage withstand test) |
- |
1000 |
|
For 100kVA |
21.5.3.3(Oil leakage test) |
- |
4500 |
|
For 100kVA |
21.3(a )(Lightning impulse test) |
- |
25000 |
|
For 100kVA |
21.3(b)(Temperature-rise test) |
- |
12000 |
|
For 100kVA |
21.3(c)(Short-circuit withstand test) |
- |
43000 |
|
For 100kVA |
21.4 a)( Determination of sound levels) |
- |
4500 |
|
For 100kVA |
21.5.1.1(Pressure test-Type test (For Transformers up to 200 kVA
)) |
- |
5400 |
|
For 100kVA |
21.5.1.2(Pressure test-routine test (For Transformers up to 200 kVA
)) |
- |
2500 |
|
For 100kVA |
21.5.2.1(Type test : For Transformers Above 200 kVA and Up to Including 2 500 kVA) |
- |
9000 |
|
- |
21.5.2.2(routine test :For Transformers Above 200 kVA and Up to Including 2 500 kVA) |
- |
4500 |
|
- |
21.5.2.3( Oil leakage test (routine test)) |
- |
4500 |
|
- |
21.5.3.1(For Single Phase Distribution Transformers Up to Including 25 kVA : pressure test (type test)) |
- |
5000 |
|
- |
21.5.3.2(For Single Phase Distribution Transformers Up to Including 25 kVA : pressure test (routine test)) |
- |
2500 |
|
- |
21.5.3.3(Oil leakage test (routine test)) |
- |
5000 |
|
- |
21.4 c(No load current at 112.5 percent voltage.) |
- |
1400 |
|
For 100kVA |
21.4 d(Paint adhesion tests) |
- |
3000 |
|
For 100kVA |
15.5(Total Dry Film Paint Thickness) |
- |
500 |
|
For 100kVA |
21.4 e(BDV and moisture content of oil in the transformer) |
- |
1200 |
|
For 100kVA |
6.9, 7.9, 8.9(Permissible Flux Density and Over Fluxing) |
- |
6200 |
|
For 100kVA |
11(Minimum clearance in Air) |
- |
200 |
|
For 100kVA |
6.8 (50%)(Total losses at 50 % load (Watts)) |
- |
3000 |
|
- |
7.8 (50%)(Total losses at 50 % load (Watts)) |
- |
5000 |
|
- |
8.8 (50%)(Total losses at 50 % load (Watts)) |
- |
2500 |
|
- |
6.8 (100%)(Total losses at 100 % load (Watts)) |
- |
3000 |
|
- |
8.8 (100%)(Total losses at 100 % load (Watts)) |
- |
2500 |
|
- |
21.5.1.3(Oil leakage test upto 200 KVA) |
- |
4500 |
|
- |
17( ABILITY OF TRANSFORMERS TO
WITHSTAND EXTERNAL SHORT CIRCUIT
) |
- |
52000 |
|
- |
16(Conservator for Non-sealed type Transformers) |
- |
200 |
|
For 100kVA |
13.1(Marking (Rating Plates)) |
- |
200 |
|
For 100kVA |
13.2(Terminal Marking Plate) |
- |
200 |
|
For 100kVA |
13.3(Marking ) |
- |
200 |
|
For 100kVA |
13.4(Marking) |
- |
200 |
|
For 100kVA |
13.4.1(Marking) |
- |
200 |
|
For 100kVA |
14.1(MOUNTING ARRANGEMENT) |
- |
200 |
|
For 100kVA |
14.2(MOUNTING ARRANGEMENT) |
- |
200 |
|
For 100kVA |
14.3(MOUNTING ARRANGEMENT) |
- |
200 |
|
For 100kVA |
14.4(MOUNTING ARRANGEMENT) |
- |
200 |
|
For 100kVA |
15.1.1(TRANSFORMER TANK : Construction) |
- |
200 |
|
For 100kVA |
15.1.2(TRANSFORMER TANK : Construction) |
- |
200 |
|
For 100kVA |
15.1.3(TRANSFORMER TANK : Construction) |
- |
200 |
|
For 100kVA |
15.1.4(TRANSFORMER TANK : Construction) |
- |
200 |
|
For 100kVA |
15.1.5(TRANSFORMER TANK : Construction) |
- |
200 |
|
For 100kVA |
20(Fittings) |
- |
200 |
|
For 100kVA |
|
Complete
|
22 Jul, 2022 |
14 Jul, 2025 |
- Excluding : Break Down Voltage Test of Oil, Paint Adhesion Test and Short Circuit Test (above 200 kVA). |
27 |
Central Power Research Institute (CPRI), Bangalore
| IS 1180 : Part 1 (2014) |
Outdoor Type Oil Immersed Distribution Transformers Upto and Including 2 500 kVA, 33kV - Specification Part 1 Mineral Oil Immersed (Fourth Revision) |
- |
-
|
274000 View breakup
Complete testing charges:
Rs. 315100/- per transformer (up to 200 kVA without taps);
Rs. 365010/- per transformer (up to 200 kVA with 7 taps);
Rs. 365010/- per transformer ( above 200 kVA & up to 250 kVA with 7 taps);
Rs. 405260/- per transformer (above 250 kVA & up to 500 kVA with 7 taps);
Rs. 408840/- per transformer (1600 kVA & up to 2000 kVA with 7 taps excluding short circuit test); Rs. 443340/- per transformer (2000 kVA & up to 2500 kVA with 7 taps excluding short circuit test); Rs. 275260/- per transformer (500 kVA & up to 630 kVA with 17 taps excluding short circuit test); Rs. 284230/- per transformer (630 kVA & up to 1000 kVA with 17 taps excluding short circuit test); Rs. 399640/- per transformer (1000 kVA & up to 1600 kVA with 17 taps excluding short circuit test).
Test charges will vary depending on the rating of the sample. The applicable test charges will be intimated through a proforma invoice.
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
21.2 a)(Measurement of winding resistance ) |
- |
5100 |
|
Test charges will vary depending on the kVA & Tappings of the Transformer
Test charge applicable will be intimated through a proforma invoice |
21.2 b)( Measurement of voltage ratio and check of
phase displacemen) |
- |
3400 |
|
Test charges will vary depending on the kVA & Tappings of the Transformer
Test charge applicable will be intimated through a proforma invoice |
21.2 c)( Measurement of short-circuit impedance
(principal tapping, when applicable) and load
loss at 50 percent and 100 percent load) |
- |
10150 |
|
Test charges will vary depending on the kVA & Tappings of the Transformer
Test charge applicable will be intimated through a proforma invoice |
21.2 d)(Measurement of no-load loss and current) |
- |
10150 |
|
Test charges will vary depending on the kVA & Tappings of the Transformer
Test charge applicable will be intimated through a proforma invoice |
21.2 e)(Measurement of insulation resistance) |
- |
2550 |
|
Test charges will vary depending on the kVA & Tappings of the Transformer
Test charge applicable will be intimated through a proforma invoice |
21.2 f)(Induced over-voltage withstand test) |
- |
3200 |
|
Test charges will vary depending on the kVA & Tappings of the Transformer
Test charge applicable will be intimated through a proforma invoice |
21.2 g)( Separate-source voltage withstand test) |
- |
1700 |
|
Test charges will vary depending on the kVA & Tappings of the Transformer
Test charge applicable will be intimated through a proforma invoice |
21.3(b)(Temperature-rise test) |
- |
41600 |
|
Test charges will vary depending on the kVA & Tappings of the Transformer
Test charge applicable will be intimated through a proforma invoice |
21.3(c)(Short-circuit withstand test) |
- |
84450 |
|
Test charges will vary depending on the kVA & Tappings of the Transformer
Test charge applicable will be intimated through a proforma invoice |
21.4 c(No load current at 112.5 percent voltage.) |
- |
1700 |
|
Test charges will vary depending on the kVA & Tappings of the Transformer
Test charge applicable will be intimated through a proforma invoice |
21.5.1.1(Pressure test-Type test (For Transformers up to 200 kVA
)) |
- |
11000 |
|
Test charges will vary depending on the kVA & Tappings of the Transformer
Test charge applicable will be intimated through a proforma invoice |
21.5.1.2(Pressure test-routine test (For Transformers up to 200 kVA
)) |
- |
11000 |
|
Test charges will vary depending on the kVA & Tappings of the Transformer
Test charge applicable will be intimated through a proforma invoice |
21.5.2.1(Type test : For Transformers Above 200 kVA and Up to Including 2 500 kVA) |
- |
11000 |
|
Test charges will vary depending on the kVA & Tappings of the Transformer
Test charge applicable will be intimated through a proforma invoice |
21.5.2.2(routine test :For Transformers Above 200 kVA and Up to Including 2 500 kVA) |
- |
11000 |
|
Test charges will vary depending on the kVA & Tappings of the Transformer
Test charge applicable will be intimated through a proforma invoice |
21.5.2.3( Oil leakage test (routine test)) |
- |
5500 |
|
Test charges will vary depending on the kVA & Tappings of the Transformer
Test charge applicable will be intimated through a proforma invoice |
21.5.3.3(Oil leakage test (routine test)) |
- |
5500 |
|
Test charges will vary depending on the kVA & Tappings of the Transformer
Test charge applicable will be intimated through a proforma invoice |
21.5.3.1(For Single Phase Distribution Transformers Up to Including 25 kVA : pressure test (type test)) |
- |
11000 |
|
Test charges will vary depending on the kVA & Tappings of the Transformer
Test charge applicable will be intimated through a proforma invoice |
21.5.3.2(For Single Phase Distribution Transformers Up to Including 25 kVA : pressure test (routine test)) |
- |
11000 |
|
Test charges will vary depending on the kVA & Tappings of the Transformer
Test charge applicable will be intimated through a proforma invoice |
21.4 d(Paint adhesion tests) |
- |
2400 |
|
Test charges will vary depending on the kVA & Tappings of the Transformer
Test charge applicable will be intimated through a proforma invoice |
21.4 a)( Determination of sound levels) |
- |
28800 |
|
Test charges will vary depending on the kVA & Tappings of the Transformer
Test charge applicable will be intimated through a proforma invoice |
21.3(a )(Lightning impulse test) |
- |
58300 |
|
Test charges will vary depending on the kVA & Tappings of the Transformer
Test charge applicable will be intimated through a proforma invoice |
21.4 e(BDV and moisture content of oil in the transformer) |
- |
3000 |
|
Test charges will vary depending on the kVA & Tappings of the Transformer
Test charge applicable will be intimated through a proforma invoice |
|
Complete
|
|
31 Dec, 2026 |
- - |
28 |
National Test House (NR)
| IS 1180 : Part 1 (2014) |
Outdoor Type Oil Immersed Distribution Transformers Upto and Including 2 500 kVA, 33kV - Specification Part 1 Mineral Oil Immersed (Fourth Revision) |
Distribution Transformers 11 KV upto 2500 KVA Rating |
-
|
105000 View breakup
Rs.48000/- for rating upt 100 kVA, Rs.75000/- for rating 101 kVA to 200kVA, Rs.85000/- for rating 201 kVA to 500 kVA, Rs.95000/- for rating 501 kVA to 1000 kVA, Rs.1,05,000/- for rating 1001 kVA to 2500 kVA
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
21.2 e)(Measurement of insulation resistance) |
- |
500 |
|
- |
13.1(Marking (Rating Plates)) |
- |
0 |
|
- |
13.2(Terminal Marking Plate) |
- |
0 |
|
- |
13.3(Marking ) |
- |
0 |
|
- |
13.4(Marking) |
- |
0.00 |
|
- |
13.4.1(Marking) |
- |
0.00 |
|
- |
14.1(MOUNTING ARRANGEMENT) |
- |
0 |
|
- |
14.2(MOUNTING ARRANGEMENT) |
- |
0 |
|
- |
14.3(MOUNTING ARRANGEMENT) |
- |
0 |
|
- |
14.4(MOUNTING ARRANGEMENT) |
- |
0 |
|
- |
15.1.1(TRANSFORMER TANK : Construction) |
- |
0 |
|
- |
15.1.2(TRANSFORMER TANK : Construction) |
- |
0 |
|
- |
15.1.3(TRANSFORMER TANK : Construction) |
- |
0 |
|
- |
15.1.4(TRANSFORMER TANK : Construction) |
- |
0 |
|
- |
15.1.5(TRANSFORMER TANK : Construction) |
- |
0 |
|
- |
17( ABILITY OF TRANSFORMERS TO
WITHSTAND EXTERNAL SHORT CIRCUIT
) |
- |
0 |
|
- |
21.2 a)(Measurement of winding resistance ) |
- |
1000 |
|
- |
21.2 b)( Measurement of voltage ratio and check of
phase displacemen) |
- |
1000 |
|
- |
21.2 c)( Measurement of short-circuit impedance
(principal tapping, when applicable) and load
loss at 50 percent and 100 percent load) |
- |
5000 |
|
- |
21.2 d)(Measurement of no-load loss and current) |
- |
5000 |
|
- |
21.2 f)(Induced over-voltage withstand test) |
- |
1000 |
|
- |
21.2 g)( Separate-source voltage withstand test) |
- |
1000 |
|
- |
21.3(a )(Lightning impulse test) |
- |
35000 |
|
- |
21.5.3.3(Oil leakage test) |
- |
2000 |
|
- |
21.3(b)(Temperature-rise test) |
- |
25000 |
|
- |
21.3(c)(Short-circuit withstand test) |
- |
0 |
|
- |
21.4 a)( Determination of sound levels) |
- |
2000 |
|
- |
21.5.1.1(Pressure test-Type test (For Transformers up to 200 kVA
)) |
- |
6000 |
|
- |
21.5.1.2(Pressure test-routine test (For Transformers up to 200 kVA
)) |
- |
3000 |
|
- |
21.5.2.1(Type test : For Transformers Above 200 kVA and Up to Including 2 500 kVA) |
- |
0 |
|
- |
21.5.2.2(routine test :For Transformers Above 200 kVA and Up to Including 2 500 kVA) |
- |
0 |
|
- |
21.5.2.3( Oil leakage test (routine test)) |
- |
2000 |
|
- |
21.5.3.1(For Single Phase Distribution Transformers Up to Including 25 kVA : pressure test (type test)) |
- |
0 |
|
- |
21.5.3.2(For Single Phase Distribution Transformers Up to Including 25 kVA : pressure test (routine test)) |
- |
0 |
|
- |
21.5.3.3(Oil leakage test (routine test)) |
- |
2000 |
|
- |
21.4 b(Short-circuit withstand test IS 2026 (Part 5) (above 200 kVA)) |
- |
0 |
|
- |
21.4 c(No load current at 112.5 percent voltage.) |
- |
2500 |
|
- |
21.4 d(Paint adhesion tests) |
- |
1000 |
|
- |
21.4 e(BDV and moisture content of oil in the transformer) |
- |
4000 |
|
- |
6.9, 7.9, 8.9(Permissible Flux Density and Over Fluxing) |
- |
6000 |
|
- |
11(Minimum clearance in Air) |
- |
0 |
|
- |
16(Conservator for Non-sealed type Transformers) |
- |
0 |
|
- |
20(Fittings) |
- |
0 |
|
- |
15.5(Total Dry Film Paint Thickness) |
- |
0 |
|
- |
|
Complete
|
|
26 Oct, 2025 |
- Excluding: Short Curcuit test as per Cl.21.4(b) |