| 61 |
Hi Physix Laboratory India Private Limited, Pune
| 7126926
| IS 13252 : Part 1 (2010) |
Information technology equipment - Safety: Part 1 general requirements (Second Revision) |
- |
138952 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 1.5(Components) |
- |
5000 |
|
- |
| 1.6(Power interface .) |
- |
5000 |
|
- |
| 1.7(Markings and instructions) |
- |
3000 |
|
- |
| 2.1(Protection from electric shock and energy hazards) |
- |
5000 |
|
- |
| 2.2(SELV circuits) |
- |
5000 |
|
- |
| 2.3(TNV circuits) |
- |
5000 |
|
- |
| 2.4(Limited current circuits) |
- |
3000 |
|
- |
| 2.5(Limited power sources .) |
- |
5000 |
|
- |
| 2.6(Provisions for earthing and bonding) |
- |
5000 |
|
- |
| 2.7(Overcurrent and earth fault protection in primary circuits) |
- |
3000 |
|
- |
| 2.8(Safety interlocks) |
- |
0 |
|
- |
| 2.9(Electrical insulation) |
- |
35000 |
|
Testing charges for Cl. 2.9 will be variable as per size of products .Minimum charges will be 10000. |
| 2.10(Clearances, creepage distances and distances through insulation) |
- |
10000 |
|
- |
| 3.1(General) |
- |
2000 |
|
- |
| 3.2(Connection to a mains supply) |
- |
3000 |
|
- |
| 3.3(Wiring terminals for connection of external conductors) |
- |
5000 |
|
- |
| 3.4(Disconnection from the mains supply) |
- |
3000 |
|
- |
| 3.5(Interconnection of equipment) |
- |
3000 |
|
- |
| 4.1(Stability) |
- |
5000 |
|
- |
| 4.2(Mechanical strength) |
- |
5000 |
|
- |
| 4.3(Design and construction) |
- |
8000 |
|
- |
| 4.4(Protection against hazardous moving parts) |
- |
5000 |
|
- |
| 4.5(Thermal requirements) |
- |
5000 |
|
- |
| 4.6(Openings in enclosures) |
- |
4000 |
|
- |
| 4.7(Resistance to fire) |
- |
5000 |
|
- |
| 5.1(Touch current and protective conductor curren) |
- |
3000 |
|
- |
| 5.2(Electric strength) |
- |
3000 |
|
- |
| 5.3(Abnormal operating and fault conditions) |
- |
5000 |
|
- |
| 6.1(Protection of telecommunication network service persons, and users of other equipment connected to the network, from hazards in the equipment) |
- |
2000 |
|
- |
| 6.2(Protection of equipment users from overvoltages on networks telecommunication) |
- |
2000 |
|
- |
| 6.3(Protection of the telecommunication wiring system from overheating) |
- |
3000 |
|
- |
| 7.1(General) |
- |
2000 |
|
- |
| 7.2(Protection of cable distribution system service persons, and users of other equipment connected to the system, from hazardous voltages in the equipment) |
- |
5000 |
|
- |
| 7.3(Protection of equipment users from overvoltages on the cable distribution system) |
- |
5000 |
|
- |
| 7.4(Insulation between primary circuits and cable distribution systems) |
- |
3000 |
|
- |
|
20 Jun, 2028 |
- Excluding following tests: Thermal Controls Test (Cl. 1.5.3), Capacitors Bridging Insulation (Cl. 1.5.6), Surge Suppressors (General) (Cl. 1.5.9.1 & Annex Q), Safety Interlocks (Cl. 2.8.5, Cl. 2.8.7), Semiconductor Devices (Only Opto-coupler Tests as per IEC 60747-5-5) (Cl. 2.10.5.4 ), Cl.2.10.6Construction of Printed Boards (Except Dimensional Measurements),Cl.2.10.7Components External Terminations (Except Dimensional Measurements), Cl.2.10.8Tests on Coated Printed Boards &Coated Components (Except Dimensional Measurements), AC Power Supply Cords (Except Cross sectional area of Cable/ Cords) (Cl. 3.2.5.1), Cathode Ray Tubes (Cl. 4.2.8), Flammable Liquids (Cl. 4.3.12), Ionizing Radiation (Cl. 4.3.13.2), Effect of Ultraviolet (UV) Radiation on materials (Cl. 4.3.13.3), Human Exposure to Ultraviolet (UV) Radiation (Cl. 4.3.13.4), Lasers (including Laser Diodes) and LEDs (Cl. 4.3.13.5) |
| 62 |
UL India Private limited, Gurgaon
| 8127226
| IS 13252 : Part 1 (2010) |
Information technology equipment - Safety: Part 1 general requirements (Second Revision) |
- |
195000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 1.6(Power interface .) |
- |
5000 |
|
Test |
| 1.7(Markings and instructions) |
- |
1000 |
|
Test |
| 2.1(Protection from electric shock and energy hazards) |
- |
8000 |
|
Test |
| 2.2(SELV circuits) |
- |
3000 |
|
Test |
| 2.3(TNV circuits) |
- |
5000 |
|
Test |
| 2.4(Limited current circuits) |
- |
3000 |
|
Test |
| 2.5(Limited power sources .) |
- |
5000 |
|
Test |
| 2.6(Provisions for earthing and bonding) |
- |
3000 |
|
Test |
| 2.7(Overcurrent and earth fault protection in primary circuits) |
- |
2000 |
|
Test |
| 2.8(Safety interlocks) |
- |
2500 |
|
Visual |
| 2.9(Electrical insulation) |
- |
37000 |
|
Test |
| 2.10(Clearances, creepage distances and distances through insulation) |
- |
22000 |
|
Measurement |
| 3.1(General) |
- |
1000 |
|
Visual |
| 3.2(Connection to a mains supply) |
- |
2500 |
|
Visual |
| 3.3(Wiring terminals for connection of external conductors) |
- |
1000 |
|
Visual |
| 3.4(Disconnection from the mains supply) |
- |
1000 |
|
Visual |
| 3.5(Interconnection of equipment) |
- |
1000 |
|
Visual |
| 4.1(Stability) |
- |
1000 |
|
Test |
| 4.2(Mechanical strength) |
- |
15000 |
|
Test |
| 4.3(Design and construction) |
- |
10000 |
|
Test |
| 4.4(Protection against hazardous moving parts) |
- |
500 |
|
Visual |
| 4.5(Thermal requirements) |
- |
16000 |
|
Test |
| 4.6(Openings in enclosures) |
- |
16000 |
|
Test |
| 4.7(Resistance to fire) |
- |
5000 |
|
Test |
| 5.1(Touch current and protective conductor curren) |
- |
3000 |
|
Test |
| 5.2(Electric strength) |
- |
3000 |
|
Test |
| 5.3(Abnormal operating and fault conditions) |
- |
5000 |
|
Test |
| 6.1(Protection of telecommunication network service persons, and users of other equipment connected to the network, from hazards in the equipment) |
- |
2000 |
|
Test |
| 6.2(Protection of equipment users from overvoltages on networks telecommunication) |
- |
2000 |
|
Test |
| 6.3(Protection of the telecommunication wiring system from overheating) |
- |
2000 |
|
Test |
| 7.1(General) |
- |
500 |
|
Visual |
| 7.2(Protection of cable distribution system service persons, and users of other equipment connected to the system, from hazardous voltages in the equipment) |
- |
2000 |
|
Test |
| 7.3(Protection of equipment users from overvoltages on the cable distribution system) |
- |
1000 |
|
Test |
| 7.4(Insulation between primary circuits and cable distribution systems) |
- |
500 |
|
Test |
| 1.5(Components) |
- |
1000 |
|
Visual verification of components and associated certificates |
| 2.8.2/2.8.5(Interlock switches) |
- |
1000 |
|
Visual verification of components and associated certificates |
| 2.8.7(Switches and Relay) |
- |
500 |
|
Visual verification of components and associated certificates |
| 2.10.5.4(Opto-coupler) |
- |
500 |
|
Visual verification of components and associated certificates |
| 2.10.5.12(Wires in wound components) |
- |
500 |
|
Visual verification of components and associated certificates |
| 2.10.6(PCB material) |
- |
500 |
|
Visual verification of components and associated certificates |
| 3.2.5(Non re-wirable plug with PVC sheathed cable) |
- |
500.0 |
|
Visual verification of components and associated certificates |
| 4.2.8(Cathode Ray Tubes) |
- |
0 |
|
Not applicable as no products with such construction |
| 4.3.12(Flammable liquids) |
- |
0 |
|
Not applicable as no products with such construction |
| 4.3.13.2(Ionizing radiation) |
- |
0 |
|
Not applicable as no products with such construction |
| 4.3.13.3/ Annex Y(Effect of UV radiation on material/Ultraviolet conditioning test) |
- |
0 |
|
Not applicable as no products with such construction |
| 4.3.13.4(Human exposure to ultraviolet (UV) radiation) |
- |
500 |
|
Visual verification of components and associated certificates |
| 4.3.13.5(LED, laser class) |
- |
500 |
|
Visual verification of components and associated certificates |
| Annex A3(Hot flaming oil test) |
- |
0 |
|
Not applicable as no products with such construction not applicable |
| Annex U(Insulating winding wires for use without interleaved insulation) |
- |
500 |
|
Visual verification of components and associated certificates |
| Annex CC(Evaluation of integrated circuit (IC) current limiters) |
- |
500 |
|
Visual verification of components and associated certificates |
| Annex K(Thermal Control) |
- |
500 |
|
Visual verification of components and associated certificates |
| Annex Q(Voltage Dependent Resistors) |
- |
500 |
|
Visual verification of components and associated certificates |
| 4.3.10(Dust, powders, liquids and gases) |
- |
0 |
|
Not applicable as no products with such construction |
| 4.3.11(Containers for liquids or gases) |
- |
0 |
|
Not applicable as no products with such construction |
|
- |
- Excluding:
Cl. 1.5 (Components), Cl. 2.8.2/2.8.5 (Interlock switches), Cl. 2.8.7 (Switches and Relay), Cl. 2.10.5.4 (Opto-coupler), Cl. 2.10.5.12 (Wires in wound components), Cl. 2.10.6 (PCB material), Cl. 3.2.5 (Non re-wirable plug with PVC sheathed cable), Cl. 4.3.13.2 (Ionizing radiation), Cl. 4.3.13.3/ Annex Y (Effect of UV radiation on material/Ultraviolet conditioning test), Cl. 4.3.13.4 (Human exposure to ultraviolet (UV) radiation), Cl. 4.3.13.5 (LED, laser class), Cl. Annex U (Insulating winding wires for use without interleaved insulation), Cl. Annex CC (Evaluation of integrated circuit (IC) current limiters), Annex K (Thermal Control), Annex Q (Voltage Dependent Resistors) |
| 63 |
Yadav Measurements Pvt Ltd, Udaipur
| 8116426
| IS 13252 : Part 1 (2010) |
Information technology equipment - Safety: Part 1 general requirements (Second Revision) |
- |
80000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 1.7(Markings and instructions) |
- |
2330 |
|
Complete testing charges for different product is between Rs 56500 and Rs 80000.
For this test charges for different product is between Rs 1646 and Rs 2330 |
| 1.6(Power interface .) |
- |
777 |
|
For this test charges for different product is between Rs 549 and Rs 777 |
| 2.1(Protection from electric shock and energy hazards) |
- |
777 |
|
For this test charges for different product is between Rs 549 and Rs 777 |
| 2.3(TNV circuits) |
- |
1553 |
|
For this test charges for different product is between Rs 1097 and Rs 1553 |
| 2.4(Limited current circuits) |
- |
777 |
|
For this test charges for different product is between Rs 549 and Rs 777 |
| 2.6(Provisions for earthing and bonding) |
- |
777 |
|
For this test charges for different product is between Rs 549 and Rs 777 |
| 2.7(Overcurrent and earth fault protection in primary circuits) |
- |
777 |
|
For this test charges for different product is between Rs 549 and Rs 777 |
| 2.2(SELV circuits) |
- |
1553 |
|
For this test charges for different product is between Rs 1097 and Rs 1553 |
| 2.8(Safety interlocks) |
- |
194 |
|
For this test charges for different product is between Rs 137 and Rs 194 |
| 2.9(Electrical insulation) |
- |
777 |
|
For this test charges for different product is between Rs 549 and Rs 777 |
| 2.10(Clearances, creepage distances and distances through insulation) |
- |
4660 |
|
For this test charges for different product is between Rs 3291 and Rs 4660 |
| 3.1(General) |
- |
777 |
|
For this test charges for different product is between Rs 549 and Rs 777 |
| 3.2(Connection to a mains supply) |
- |
777 |
|
For this test charges for different product is between Rs 549 and Rs 777 |
| 3.3(Wiring terminals for connection of external conductors) |
- |
777 |
|
For this test charges for different product is between Rs 549 and Rs 777 |
| 4.1(Stability) |
- |
777 |
|
For this test charges for different product is between Rs 549 and Rs 777 |
| 4.2(Mechanical strength) |
- |
777 |
|
For this test charges for different product is between Rs 549 and Rs 777 |
| 4.3(Design and construction) |
- |
777 |
|
For this test charges for different product is between Rs 549 and Rs 777 |
| 4.4(Protection against hazardous moving parts) |
- |
777 |
|
For this test charges for different product is between Rs 549 and Rs 777 |
| 4.5(Thermal requirements) |
- |
9320 |
|
For this test charges for different product is between Rs 6583 and Rs 9320 |
| 4.6(Openings in enclosures) |
- |
777 |
|
For this test charges for different product is between Rs 549 and Rs 777 |
| 4.7(Resistance to fire) |
- |
6214 |
|
For this test charges for different product is between Rs 4388 and Rs 6214 |
| 5.1(Touch current and protective conductor curren) |
- |
777 |
|
For this test charges for different product is between Rs 549 and Rs 777 |
| 5.2(Electric strength) |
- |
19417 |
|
For this test charges for different product is between Rs 13714 and Rs 19417 |
| 5.3(Abnormal operating and fault conditions) |
- |
4660 |
|
For this test charges for different product is between Rs 3291 and Rs 4660 |
| 6.1(Protection of telecommunication network service persons, and users of other equipment connected to the network, from hazards in the equipment) |
- |
777 |
|
For this test charges for different product is between Rs 549 and Rs 777 |
| 6.2(Protection of equipment users from overvoltages on networks telecommunication) |
- |
777 |
|
For this test charges for different product is between Rs 549 and Rs 777 |
| 7.2(Protection of cable distribution system service persons, and users of other equipment connected to the system, from hazardous voltages in the equipment) |
- |
777 |
|
For this test charges for different product is between Rs 549 and Rs 777 |
| 7.3(Protection of equipment users from overvoltages on the cable distribution system) |
- |
5437 |
|
For this test charges for different product is between Rs 3840 and Rs 5437 |
| 7.4(Insulation between primary circuits and cable distribution systems) |
- |
7767 |
|
For this test charges for different product is between Rs 5485 and Rs 7767 |
| Annex A3(Hot flaming oil test) |
- |
1 |
|
For this test charges for different product |
| Annex B(Motor tests under abnormal conditions) |
- |
1 |
|
For this test charges for different product is |
| Annex C(Transformers) |
- |
1 |
|
For this test charges for different product is between |
| Annex DD(Requirements for the mounting means of a rack mounted equipment) |
- |
1 |
|
For this test charges for different product is between |
| Annex U(Insulating winding wires for use without interleaved insulation) |
- |
1 |
|
For this test charges for different product is between |
| Annex K(Thermal Control) |
- |
1 |
|
For this test charges for different product is between |
| Annex EE(Household and home/ office document/ media shredders) |
- |
1 |
|
For this test charges for different product is between Rs |
|
- |
- Excluding:
Cl. 1.5 (Components), Cl. 2.10.5.4 (Opto-coupler), 2.10.6 (PCB material), Cl. 2.10.8.4 (Abrasion resistance test)`, 3.2.4 (Appliance inlet /connector), Cl. 4.2.8 (Cathode Ray Tubes), Cl. 4.3.8 (Batteries), Cl. 4.3.12 (Flammable liquids), Cl. 4.3.13.2 (Ionizing radiation), Cl. 4.3.13.3/ Annex Y (Effect of UV radiation on material/Ultraviolet conditioning test), Cl. 4.3.13.4 (Human exposure to ultraviolet (UV) radiation), Cl. 4.3.13.5 (LED, laser class) |
| 64 |
SKC COMPLIANCE LAB PRIVATE LIMITED, MAHADEVPURA
| 6170406
| IS 13252 : Part 1 (2010) |
Information technology equipment - Safety: Part 1 general requirements (Second Revision) |
- |
120000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 1.7(Markings and instructions) |
- |
3500 |
|
10% discount for BIS |
| 1.6(Power interface .) |
- |
5000 |
|
10% discount for BIS |
| 2.1(Protection from electric shock and energy hazards) |
- |
7000 |
|
10% discount for BIS |
| 2.2(SELV circuits) |
- |
3000 |
|
10% discount for BIS |
| 2.3(TNV circuits) |
- |
3000 |
|
10% discount for BIS |
| 2.4(Limited current circuits) |
- |
1000 |
|
10% discount for BIS |
| 2.5(Limited power sources .) |
- |
1500 |
|
10% discount for BIS |
| 2.6(Provisions for earthing and bonding) |
- |
4500 |
|
10% discount for BIS |
| 2.7(Overcurrent and earth fault protection in primary circuits) |
- |
1000 |
|
10% discount for BIS |
| 2.8(Safety interlocks) |
- |
1000 |
|
10% discount for BIS |
| 2.9(Electrical insulation) |
- |
10000 |
|
10% discount for BIS |
| 2.10(Clearances, creepage distances and distances through insulation) |
- |
8000 |
|
10% discount for BIS |
| 3.1(General) |
- |
1000 |
|
10% discount for BIS |
| 3.2(Connection to a mains supply) |
- |
2000 |
|
10% discount for BIS |
| 3.3(Wiring terminals for connection of external conductors) |
- |
3000 |
|
10% discount for BIS |
| 3.5(Interconnection of equipment) |
- |
500 |
|
10% discount for BIS |
| 4.1(Stability) |
- |
2500 |
|
10% discount for BIS |
| 4.2(Mechanical strength) |
- |
8000 |
|
10% discount for BIS |
| 4.3(Design and construction) |
- |
5000 |
|
10% discount for BIS |
| 4.4(Protection against hazardous moving parts) |
- |
500 |
|
10% discount for BIS |
| 4.5(Thermal requirements) |
- |
6000 |
|
10% discount for BIS |
| 4.6(Openings in enclosures) |
- |
2000 |
|
10% discount for BIS |
| 4.7(Resistance to fire) |
- |
2500 |
|
10% discount for BIS |
| 5.1(Touch current and protective conductor curren) |
- |
2500 |
|
10% discount for BIS |
| 5.2(Electric strength) |
- |
3500 |
|
10% discount for BIS |
| 5.3(Abnormal operating and fault conditions) |
- |
4500 |
|
10% discount for BIS |
| 6.1(Protection of telecommunication network service persons, and users of other equipment connected to the network, from hazards in the equipment) |
- |
500 |
|
10% discount for BIS |
| 6.2(Protection of equipment users from overvoltages on networks telecommunication) |
- |
500 |
|
10% discount for BIS |
| 6.3(Protection of the telecommunication wiring system from overheating) |
- |
500 |
|
10% discount for BIS |
| 7.2(Protection of cable distribution system service persons, and users of other equipment connected to the system, from hazardous voltages in the equipment) |
- |
500 |
|
10% discount for BIS |
| 7.3(Protection of equipment users from overvoltages on the cable distribution system) |
- |
500 |
|
10% discount for BIS |
| 7.4(Insulation between primary circuits and cable distribution systems) |
- |
500 |
|
10% discount for BIS |
| 3.4(Disconnection from the mains supply) |
- |
1000 |
|
10% discount for BIS |
| 7.1(General) |
- |
500 |
|
10% discount for BIS |
| 1.5(Components) |
- |
5000 |
|
10% discount for BIS |
| 1.5(Components) |
- |
5000 |
|
10% discount for BIS |
| 2.8.2/2.8.5(Interlock switches) |
- |
1000 |
|
10% discount for BIS |
| 2.8.7(Switches and Relay) |
- |
1000 |
|
10% discount for BIS |
| 2.10.4.2(Material Group and Comparative Tracking Index) |
- |
3000 |
|
10% discount for BIS |
| 2.10.5.3(Insulating Compound as Solid Insulation) |
- |
500 |
|
10% discount for BIS |
| 2.10.5.4(Opto-coupler) |
- |
500 |
|
10% discount for BIS |
| 2.10.5.6(Thin sheet materials) |
- |
500 |
|
10% discount for BIS |
| 2.10.5.11(SMPS Transformer and Inductor) |
- |
500 |
|
10% discount for BIS |
| 2.10.5.12(Wires in wound components) |
- |
500 |
|
10% discount for BIS |
| 2.10.5.13(Winding wire) |
- |
500 |
|
10% discount for BIS |
| 2.10.5.14(Additional insulation in wound components) |
- |
500 |
|
10% discount for BIS |
| 2.10.6(PCB material) |
- |
500 |
|
10% discount for BIS |
| 2.10.8.2(Thermal conditioning (thermal ageing)) |
- |
500 |
|
10% discount for BIS |
| 2.10.8.4(Abrasion resistance test) |
- |
500 |
|
10% discount for BIS |
| 2.10.9(Thermal Cycling) |
- |
1000 |
|
10% discount for BIS |
| 2.10.10(Test for Pollution Degree 1 environment and for insulating compound) |
- |
500 |
|
10% discount for BIS |
| 2.10.11(Tests for semiconductor devices and for cemented joints) |
- |
500 |
|
10% discount for BIS |
| 2.10.12(Enclosed and sealed parts) |
- |
500 |
|
10% discount for BIS |
| 3.1.4(Internal wire) |
- |
500 |
|
10% discount for BIS |
| 3.2.4(Appliance inlet /connector) |
- |
500 |
|
10% discount for BIS |
| 3.2.5(Non re-wirable plug with PVC sheathed cable) |
- |
500 |
|
10% discount for BIS |
| 4.3.8(Batteries) |
- |
2500 |
|
10% discount for BIS |
| 4.3.10(Dust, powders, liquids and gases) |
- |
500 |
|
10% discount for BIS |
| 4.3.11(Containers for liquids or gases) |
- |
500 |
|
10% discount for BIS |
| 4.3.12(Flammable liquids) |
- |
500 |
|
10% discount for BIS |
| Annex A3(Hot flaming oil test) |
- |
1000 |
|
10% discount for BIS |
| Annex U(Insulating winding wires for use without interleaved insulation) |
- |
500 |
|
10% discount for BIS |
| Annex CC(Evaluation of integrated circuit (IC) current limiters) |
- |
500 |
|
10% discount for BIS |
| Annex K(Thermal Control) |
- |
500 |
|
10% discount for BIS |
| Annex Q(Voltage Dependent Resistors) |
- |
500 |
|
10% discount for BIS |
|
24 May, 2028 |
- EXCLUSIONS: Visual Display unit, video monitors of screen size restricted up to 60" EXCLUSIONS:
Cl no.: 1.5 Components (Approved component used, verified based on certificates)
Cl no. :2.8.5 Moving parts Cl no.: 2.8.7 Switches and relay Cl no.: 2.10.5.4 Semiconductor devices Cl no.:4.2.9 High Pressure Lamps (Compliance will be checked with approved test report) Cl no.: 4.3.13 Radiation Annex A. 3: Hot flaming oil test
Annex H: lonizing radiation Annex K. Thermal Controls Annex Q: Voltage dependent
Resistors (VDRs) Annex R. Examples of requirements for quality control Programmes Annex U: Insulated winding wires for use without interleaved Insulation Annex Y: Ultraviolet Light conditioning test Annex CC: Evaluation of Integrated circuits current limiters. |
| 65 |
BLUESKY LAB LLP, GHAZIABAD
| 8170306
| IS 13252 : Part 1 (2010) |
Information technology equipment - Safety: Part 1 general requirements (Second Revision) |
- |
40000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 1.5(Components) |
- |
500 |
|
10% discount offered to BIS |
| 1.6(Power interface .) |
- |
1500 |
|
10% discount offered to BIS |
| 1.7(Markings and instructions) |
- |
1000 |
|
10% discount offered to BIS |
| 2.1(Protection from electric shock and energy hazards) |
- |
1000 |
|
10% discount offered to BIS |
| 2.2(SELV circuits) |
- |
1500 |
|
10% discount offered to BIS |
| 2.3(TNV circuits) |
- |
2000 |
|
10% discount offered to BIS |
| 2.4(Limited current circuits) |
- |
2000 |
|
10% discount offered to BIS |
| 2.5(Limited power sources .) |
- |
2500 |
|
10% discount offered to BIS |
| 2.6(Provisions for earthing and bonding) |
- |
1500 |
|
10% discount offered to BIS |
| 2.8(Safety interlocks) |
- |
3000 |
|
10% discount offered to BIS |
| 2.9(Electrical insulation) |
- |
5000 |
|
10% discount offered to BIS |
| 2.10(Clearances, creepage distances and distances through insulation) |
- |
5000 |
|
10% discount offered to BIS |
| 3.1(General) |
- |
500 |
|
10% discount offered to BIS |
| 3.2(Connection to a mains supply) |
- |
2000 |
|
10% discount offered to BIS |
| 3.3(Wiring terminals for connection of external conductors) |
- |
1500 |
|
10% discount offered to BIS |
| 3.4(Disconnection from the mains supply) |
- |
1000 |
|
10% discount offered to BIS |
| 3.5(Interconnection of equipment) |
- |
1000 |
|
10% discount offered to BIS |
| 4.1(Stability) |
- |
3000 |
|
10% discount offered to BIS |
| 4.2(Mechanical strength) |
- |
1500 |
|
10% discount offered to BIS |
| 4.3(Design and construction) |
- |
3000 |
|
10% discount offered to BIS |
| 4.4(Protection against hazardous moving parts) |
- |
5000 |
|
10% discount offered to BIS |
| 4.5(Thermal requirements) |
- |
8000 |
|
10% discount offered to BIS |
| 4.6(Openings in enclosures) |
- |
3000 |
|
10% discount offered to BIS |
| 4.7(Resistance to fire) |
- |
5000 |
|
10% discount offered to BIS |
| 5.1(Touch current and protective conductor curren) |
- |
3500 |
|
10% discount offered to BIS |
| 5.2(Electric strength) |
- |
5000 |
|
10% discount offered to BIS |
| 5.3(Abnormal operating and fault conditions) |
- |
8000 |
|
10% discount offered to BIS |
| 6.1(Protection of telecommunication network service persons, and users of other equipment connected to the network, from hazards in the equipment) |
- |
2000 |
|
10% discount offered to BIS |
| 6.2(Protection of equipment users from overvoltages on networks telecommunication) |
- |
2500 |
|
10% discount offered to BIS |
| 6.3(Protection of the telecommunication wiring system from overheating) |
- |
2000 |
|
10% discount offered to BIS |
| 7.1(General) |
- |
500 |
|
10% discount offered to BIS |
| 7.2(Protection of cable distribution system service persons, and users of other equipment connected to the system, from hazardous voltages in the equipment) |
- |
1000 |
|
10% discount offered to BIS |
| 7.3(Protection of equipment users from overvoltages on the cable distribution system) |
- |
2000 |
|
10% discount offered to BIS |
| 7.4(Insulation between primary circuits and cable distribution systems) |
- |
3000 |
|
10% discount offered to BIS |
| 2.7(Overcurrent and earth fault protection in primary circuits) |
- |
1100 |
|
10% discount offered to BIS |
| Annex A3(Hot flaming oil test) |
- |
2500 |
|
10% discount offered to BIS |
| Annex C(Transformers) |
- |
1200 |
|
- |
| Annex B(Motor tests under abnormal conditions) |
- |
1500 |
|
10% discount offered to BIS |
| Annex K(Thermal Control) |
- |
800 |
|
10% discount offered to BIS |
| Annex Q(Voltage Dependent Resistors) |
- |
500 |
|
10% discount offered to BIS |
| Annex U(Insulating winding wires for use without interleaved insulation) |
- |
500 |
|
10% discount offered to BIS |
| Annex CC(Evaluation of integrated circuit (IC) current limiters) |
- |
500 |
|
10% discount offered to BIS |
| Annex DD(Requirements for the mounting means of a rack mounted equipment) |
- |
1100 |
|
10% discount offered to BIS |
| Annex EE(Household and home/ office document/ media shredders) |
- |
500 |
|
10% discount offered to BIS |
|
22 May, 2028 |
- Excluding: Component (Cl.1.5), Moving parts (Cl.2.8.5),Semiconductor devices (Cl.2.10.5.4), Insulation in wound component (Cl.2.10.5.11), Wire in wound component (Cl.2.10.5.12), Wire with solvent based enamel in wound components (Cl.2.10.5.13), Additional insulation in wound components (Cl.2.10.5.14), Test on coated printed boards and coated components (Cl.2.10.8.1), Test for Pollution Degree 1 environment and insulating compound (Cl.2.10.10), Tests for semiconductor devices and for cemented joints(Cl.2.10.11), Enclosed and sealed parts(Cl.2.10.12), Ac power supply cord(Cl.3.2.5.1), High pressure lamps (Cl.4.2.9), Radiation (Cl.4.3.13), Ionizing radiation (Cl.4.3.13.2), Effect of UV radiation on materials (Cl.4.3.13. & Annex Y), Human exposure to UV radiation (Cl.4.3.13.4), Laser including LED (Cl.4.3.13.5), Light emitting diodes (LED's) (Cl.4.3.13.5.2), Materials for air filter assemblies (4.7.3.5), Materials used in high voltage components (4.7.3.6) Electromechanical components (Cl. 5.3.5), Unattended Equipments (Cl.5.3.8) Insulating winding wires (c.2.10.5.2 & Annex U), Evaluation of IC current limiters (Annex CC) |
| 66 |
Matrix Test Labs
| 8138626
| IS 13252 : Part 1 (2010) |
Information technology equipment - Safety: Part 1 general requirements (Second Revision) |
- |
125000 View breakup
Rs. 1,00,000/- (for Laptop/ notebook/tablet, Visual display unit, video monitors of screen size up to 75", Printer & Plotters, Scanner, Power adaptor for IT equipments, Mobile phones and Mail processing machine/ postage machine/ Franking machine, Point of sale terminal, Copying machine/ duplicators, Passport Readers and Power bank for use in portable applications, Set Top Box, Telephone answering machine, Cash Registers and Smart card readers, Wireless Keyboard).
Rs. 75,000/- (For CCTV Recorders & CCTV Cameras).
Rs. 1,25,000/- for (Automatic data processing machine. Additional Products).
Rs.75,000/- (For USB driven Barcode readers, Barcode scanner, Iris scanners, Optical fingerprint scanners and Smart watches).
Rs. 75000/- for Keyboard.
Rs. 1,25,000/- for Automatic teller cash dispensing machines.
Rs. 75000/- for USB type external hard disk drive. Rs. 75000/- for USB type external solid state storage devices (above 256GB capacity).
Rs. 75000/-(for standalone switch mode power supplies (SMPS) with output voltage 48V (mx)).
Rs. 1,25,000/- (for Digital Camera)
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 1.6(Power interface .) |
- |
5000 |
|
10% discount to BIS |
| 1.7(Markings and instructions) |
- |
3000 |
|
10% discount to BIS |
| 2.1(Protection from electric shock and energy hazards) |
- |
3000 |
|
10% discount to BIS |
| 2.2(SELV circuits) |
- |
5000 |
|
10% discount to BIS |
| 2.3(TNV circuits) |
- |
5000 |
|
10% discount to BIS |
| 2.4(Limited current circuits) |
- |
5000 |
|
10% discount to BIS |
| 2.5(Limited power sources .) |
- |
5000 |
|
10% discount to BIS |
| 2.6(Provisions for earthing and bonding) |
- |
5000 |
|
10% discount to BIS |
| 2.7(Overcurrent and earth fault protection in primary circuits) |
- |
3000 |
|
10% discount to BIS |
| 2.8(Safety interlocks) |
- |
3000 |
|
10% discount to BIS |
| 2.9(Electrical insulation) |
- |
15000 |
|
10% discount to BIS |
| 2.10(Clearances, creepage distances and distances through insulation) |
- |
5000 |
|
10% discount to BIS |
| 3.1(General) |
- |
3000 |
|
10% discount to BIS |
| 3.2(Connection to a mains supply) |
- |
3000 |
|
10% discount to BIS |
| 3.3(Wiring terminals for connection of external conductors) |
- |
3000 |
|
10% discount to BIS |
| 3.5(Interconnection of equipment) |
- |
3000 |
|
10% discount to BIS |
| 4.1(Stability) |
- |
3000 |
|
10% discount to BIS |
| 4.2(Mechanical strength) |
- |
5000 |
|
10% discount to BIS |
| 4.3(Design and construction) |
- |
3000 |
|
10% discount to BIS |
| 4.4(Protection against hazardous moving parts) |
- |
10000 |
|
10% discount to BIS |
| 4.5(Thermal requirements) |
- |
5000 |
|
10% discount to BIS |
| 4.6(Openings in enclosures) |
- |
3000 |
|
10% discount to BIS |
| 4.7(Resistance to fire) |
- |
5000 |
|
10% discount to BIS |
| 5.1(Touch current and protective conductor curren) |
- |
5000 |
|
10% discount to BIS |
| 5.2(Electric strength) |
- |
5000 |
|
10% discount to BIS |
| 5.3(Abnormal operating and fault conditions) |
- |
5000 |
|
10% discount to BIS |
| 6.1(Protection of telecommunication network service persons, and users of other equipment connected to the network, from hazards in the equipment) |
- |
3000 |
|
10% discount to BIS |
| 6.2(Protection of equipment users from overvoltages on networks telecommunication) |
- |
15000 |
|
10% discount to BIS |
| 6.3(Protection of the telecommunication wiring system from overheating) |
- |
3000 |
|
10% discount to BIS |
| 7.3(Protection of equipment users from overvoltages on the cable distribution system) |
- |
3000 |
|
10% discount to BIS |
| 7.4(Insulation between primary circuits and cable distribution systems) |
- |
15000 |
|
10% discount to BIS |
| 1.5(Components) |
- |
15000 |
|
10% discount to BIS |
| 3.4(Disconnection from the mains supply) |
- |
0 |
|
- |
| 7.2(Protection of cable distribution system service persons, and users of other equipment connected to the system, from hazardous voltages in the equipment) |
- |
0 |
|
- |
|
31 Dec, 2026 |
- Following Additional
products included w.e.f.
18.09.2018:
USB driven Barcode
readers, Barcode
scanner, Iris scanners,
Optical fingerprint
scanners and Smart
watches.
Excluding:
Component (Cl.1.5),
Safety Interlocks: Safety
Interlocks: Moving parts
(Cl.2.8.5),
Switches &
Relays(Cl.2.8.7),
Contact gaps
(Cl.2.8.7.1), Endurance
test (Cl.2.8.7.3),
Semiconductor Devices
(Opto-coupler test)
(Cl.2.10.5.4), Insulation
in wound components
(Cl.2.10.5.11), Cathode
Ray Tube (Cl.4.2.8),
Flammable Liquids
(Cl.4.3.12), Ionizing
Radiation (Cl.4.3.13.2),
Effect of UV Radiation
on materials
(Cl.4.3.13.3), Human
exposure to UV radiation
(Cl.4.3.13.4), Lasers
including LED
(Cl.4.3.13.5), Bottom of
the fire enclosure/ Hot
flaming oil test (Cl.4.6.2
& Annex-A3), Insulating
winding wires (Annex U),
Evaluation of IC current
limiters (Annex CC). |
| 67 |
DELHI TEST HOUSE, Azadhpur
| 8131406
| IS 13252 : Part 1 (2010) |
Information technology equipment - Safety: Part 1 general requirements (Second Revision) |
- |
117000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 1.5(Components) |
- |
2000 |
|
- |
| 1.6(Power interface .) |
- |
5000 |
|
- |
| 1.7(Markings and instructions) |
- |
3000 |
|
- |
| 2.1(Protection from electric shock and energy hazards) |
- |
5000 |
|
- |
| 2.2(SELV circuits) |
- |
5000 |
|
- |
| 2.3(TNV circuits) |
- |
3000 |
|
- |
| 2.4(Limited current circuits) |
- |
6000 |
|
- |
| 2.5(Limited power sources .) |
- |
6000 |
|
- |
| 2.6(Provisions for earthing and bonding) |
- |
8000 |
|
- |
| 2.7(Overcurrent and earth fault protection in primary circuits) |
- |
3000 |
|
- |
| 2.8(Safety interlocks) |
- |
2000 |
|
- |
| 2.8.2/2.8.5(Interlock switches) |
- |
2000 |
|
- |
| 2.8.7(Switches and Relay) |
- |
1000 |
|
- |
| 2.9(Electrical insulation) |
- |
8000 |
|
- |
| 2.10(Clearances, creepage distances and distances through insulation) |
- |
1000 |
|
- |
| 2.10.4.2(Material Group and Comparative Tracking Index) |
- |
1000 |
|
- |
| 2.10.5.3(Insulating Compound as Solid Insulation) |
- |
500 |
|
- |
| 2.10.5.4(Opto-coupler) |
- |
100 |
|
- |
| 2.10.5.6(Thin sheet materials) |
- |
100 |
|
- |
| 2.10.5.11(SMPS Transformer and Inductor) |
- |
500 |
|
- |
| 2.10.5.12(Wires in wound components) |
- |
500 |
|
- |
| 2.10.5.13(Winding wire) |
- |
100 |
|
- |
| 2.10.5.14(Additional insulation in wound components) |
- |
200 |
|
- |
| 2.10.6(PCB material) |
- |
300 |
|
- |
| 2.10.8.2(Thermal conditioning (thermal ageing)) |
- |
2000 |
|
- |
| 2.10.8.4(Abrasion resistance test) |
- |
2000 |
|
- |
| 2.10.9(Thermal Cycling) |
- |
2000 |
|
- |
| 2.10.10(Test for Pollution Degree 1 environment and for insulating compound) |
- |
500 |
|
- |
| 2.10.11(Tests for semiconductor devices and for cemented joints) |
- |
200 |
|
- |
| 2.10.12(Enclosed and sealed parts) |
- |
200 |
|
- |
| 3.1(General) |
- |
500 |
|
- |
| 3.1.4(Internal wire) |
- |
500 |
|
- |
| 3.2(Connection to a mains supply) |
- |
1000 |
|
- |
| 3.2.4(Appliance inlet /connector) |
- |
500 |
|
- |
| 3.2.5(Non re-wirable plug with PVC sheathed cable) |
- |
500 |
|
- |
| 3.3(Wiring terminals for connection of external conductors) |
- |
1000 |
|
- |
| 3.4(Disconnection from the mains supply) |
- |
1000 |
|
- |
| 3.5(Interconnection of equipment) |
- |
1000 |
|
- |
| 4.1(Stability) |
- |
3000 |
|
- |
| 4.2(Mechanical strength) |
- |
1000 |
|
- |
| 4.2.8(Cathode Ray Tubes) |
- |
1000 |
|
- |
| 4.3(Design and construction) |
- |
2000 |
|
- |
| 4.3.8(Batteries) |
- |
500 |
|
- |
| 4.3.10(Dust, powders, liquids and gases) |
- |
3000 |
|
- |
| 4.3.11(Containers for liquids or gases) |
- |
500 |
|
- |
| 4.3.12(Flammable liquids) |
- |
1000 |
|
- |
| 4.3.13.2(Ionizing radiation) |
- |
1000 |
|
- |
| 4.3.13.3/ Annex Y(Effect of UV radiation on material/Ultraviolet conditioning test) |
- |
1000 |
|
- |
| 4.3.13.4(Human exposure to ultraviolet (UV) radiation) |
- |
1000 |
|
- |
| 4.3.13.5(LED, laser class) |
- |
1000 |
|
- |
| 4.4(Protection against hazardous moving parts) |
- |
2000 |
|
- |
| 4.5(Thermal requirements) |
- |
2000 |
|
- |
| 4.6(Openings in enclosures) |
- |
1000 |
|
- |
| 4.7(Resistance to fire) |
- |
2000 |
|
- |
| 5.1(Touch current and protective conductor curren) |
- |
2000 |
|
- |
| 5.2(Electric strength) |
- |
3000 |
|
- |
| 5.3(Abnormal operating and fault conditions) |
- |
3000 |
|
- |
| 6.1(Protection of telecommunication network service persons, and users of other equipment connected to the network, from hazards in the equipment) |
- |
1000 |
|
- |
| 6.2(Protection of equipment users from overvoltages on networks telecommunication) |
- |
1000 |
|
- |
| 6.3(Protection of the telecommunication wiring system from overheating) |
- |
1000 |
|
- |
| 7.1(General) |
- |
1000 |
|
- |
| 7.2(Protection of cable distribution system service persons, and users of other equipment connected to the system, from hazardous voltages in the equipment) |
- |
1000 |
|
- |
| 7.3(Protection of equipment users from overvoltages on the cable distribution system) |
- |
1000 |
|
- |
| 7.4(Insulation between primary circuits and cable distribution systems) |
- |
1000 |
|
- |
| Annex B(Motor tests under abnormal conditions) |
- |
2000 |
|
- |
| Annex C(Transformers) |
- |
2000 |
|
- |
| Annex DD(Requirements for the mounting means of a rack mounted equipment) |
- |
1000 |
|
- |
| Annex EE(Household and home/ office document/ media shredders) |
- |
1000 |
|
- |
|
17 Jun, 2027 |
- - |
| 68 |
Conformity Testing Labs Pvt. Ltd. Unit 2 (A33)
| 8139626
| IS 13252 : Part 1 (2010) |
Information technology equipment - Safety: Part 1 general requirements (Second Revision) |
- |
200000 View breakup
Automatic Data Processing MACHINE-RS. 79000/- (ADP), 90,000 (PROJECTOR), 1,15,000 (SERVERS)
LAPTOP/NOTEBOOK/TABLET-Rs. 78000/-/Rs. 78000/-/Rs. 55000/-
PRINTERS, PLOTTERS- Rs. 48000/- (A4 & Legal), Rs. 78000/- (A3), Rs.112000/- (> A3)
SCANNERS- Rs. 48000/- (A4 & Legal), Rs. 78000/- (A3), Rs.112000/- (> A3)
SET TOP BOX- Rs. 48000/-
TELEPHONE ANSWERING MACHINES - Rs. 78000/-
VISUAL DISPLAY UNITS, VIDEOS MONITORS OF SCREEN SIZE 32" AND ABOVE - Rs. 79000/- (up to 42"), Rs.112000/- (above 42")
WIRELESS KEYBOARDS - Rs. 48000/-
CASH REGISTERS - Rs. 78000/-
COPYING MACHINES/DUPLICATORS - Rs. 48000/- (A4 & Legal), Rs. 78000/- (A3), Rs.112000/- (> A3)
PASSPORT READER -Rs. 51000/-
POINT OF SALE TERMINALS -RS. 78000/-
MAIL PROCESSING MACHINES/POSTAGE MACHINES/FRANKING MACHINES - RS. 78000/-
POWER BANKS FOR USE IN PORTABLE APPLICATIONS -RS. 51000/-
SMART CARD READER - RS. 51000/-
MOBILE PHONES - RS. 51000/-
POWER ADAPTORS FOR IT EQUIPMENTS - RS. 48000/-
VISUAL DISPLAY UNITS, VIDEO MONITORS OF SCREEN SIZE UPTO 32- RS. 78000/-
CCTV CAMERAS/CCTV RECORDERS- RS. 48000/-
USB DRIVEN BARCODE READERS, BARCODE SCANNERS, IRIS SCANNERS, OPTICAL FINGERPRINT SCANNERS - RS. 48000/-
SMART WATCHES-RS. 48000/- FOR SMART WATCHES WITH/ WITHOUT SIM, RS. 65,000 FOR SMART WATCH WITH INPUTTING FACELITY (INCLUDING TEST CHARGES FOR MANDATING INDIAN LANGUAGE SUPPORT)
KEYBOARD- RS. 48000/-
AUTOMATIC TELLER CASH DISPENSING MACHINES- RS. 98000/-
USB TYPE EXTERNAL HARD DISK DRIVE- RS. 51000/-
USB TYPE EXTERNAL SOLID-STATE STORAGE DEVICES (ABOVE 256 GB CAPACITY)- RS. 51000/-
STANDALONE SWITCH MODE POWER WITH OUTPUT VOLTAGE 48V (MAX)- R
DIGITAL CAMERA- RS. 48000/-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 1.6(Power interface .) |
- |
5000 |
|
10% Discount offered to BIS |
| 1.5(Components) |
- |
5000 |
|
10% Discount offered to BIS |
| 1.7(Markings and instructions) |
- |
5000 |
|
10% Discount offered to BIS |
| 2.1(Protection from electric shock and energy hazards) |
- |
5000 |
|
10% Discount offered to BIS |
| 2.2(SELV circuits) |
- |
5000 |
|
10% Discount offered to BIS |
| 2.3(TNV circuits) |
- |
5000 |
|
10% Discount offered to BIS |
| 2.4(Limited current circuits) |
- |
5000 |
|
10% Discount offered to BIS |
| 2.5(Limited power sources .) |
- |
5000 |
|
10% Discount offered to BIS |
| 2.6(Provisions for earthing and bonding) |
- |
5000 |
|
10% Discount offered to BIS |
| 2.7(Overcurrent and earth fault protection in primary circuits) |
- |
5000 |
|
10% Discount offered to BIS |
| 2.8(Safety interlocks) |
- |
5000 |
|
10% Discount offered to BIS |
| 2.9(Electrical insulation) |
- |
5000 |
|
10% Discount offered to BIS |
| 2.10(Clearances, creepage distances and distances through insulation) |
- |
5000 |
|
10% Discount offered to BIS |
| 3.1(General) |
- |
5000 |
|
10% Discount offered to BIS |
| 3.2(Connection to a mains supply) |
- |
5000 |
|
10% Discount offered to BIS |
| 3.3(Wiring terminals for connection of external conductors) |
- |
5000 |
|
10% Discount offered to BIS |
| 3.4(Disconnection from the mains supply) |
- |
5000 |
|
10% Discount offered to BIS |
| 3.5(Interconnection of equipment) |
- |
5000 |
|
10% Discount offered to BIS |
| 4.1(Stability) |
- |
5000 |
|
10% Discount offered to BIS |
| 4.2(Mechanical strength) |
- |
5000 |
|
10% Discount offered to BIS |
| 4.3(Design and construction) |
- |
5000 |
|
10% Discount offered to BIS |
| 4.4(Protection against hazardous moving parts) |
- |
5000 |
|
10% Discount offered to BIS |
| 4.5(Thermal requirements) |
- |
5000 |
|
10% Discount offered to BIS |
| 4.6(Openings in enclosures) |
- |
5000 |
|
10% Discount offered to BIS |
| 4.7(Resistance to fire) |
- |
5000 |
|
10% Discount offered to BIS |
| 5.1(Touch current and protective conductor curren) |
- |
5000 |
|
10% Discount offered to BIS |
| 5.2(Electric strength) |
- |
5000 |
|
10% Discount offered to BIS |
| 5.3(Abnormal operating and fault conditions) |
- |
5000 |
|
10% Discount offered to BIS |
| 6.1(Protection of telecommunication network service persons, and users of other equipment connected to the network, from hazards in the equipment) |
- |
5000 |
|
10% Discount offered to BIS |
| 6.2(Protection of equipment users from overvoltages on networks telecommunication) |
- |
10000 |
|
10% Discount offered to BIS |
| 6.3(Protection of the telecommunication wiring system from overheating) |
- |
5000 |
|
10% Discount offered to BIS |
| 7.1(General) |
- |
5000 |
|
10% Discount offered to BIS |
| 7.2(Protection of cable distribution system service persons, and users of other equipment connected to the system, from hazardous voltages in the equipment) |
- |
10000 |
|
10% Discount offered to BIS |
| 7.3(Protection of equipment users from overvoltages on the cable distribution system) |
- |
5000 |
|
10% Discount offered to BIS |
| 7.4(Insulation between primary circuits and cable distribution systems) |
- |
5000 |
|
10% Discount offered to BIS |
|
05 Apr, 2027 |
- Components (Cl.1.5), Moving Parts (Cl.2.8.5), Overload test (Cl.2.8.7.2), Endurance Test (Cl.2.8.7.3), Coated printed boards (Cl.2.10.6.2), Effect of UV radiation on materials (Cl.4.3.13.3), Mechanical Strength Test on CRT (Cl.4.2.8), Flammable liquids (Cl.4.3.12), Ionizing radiation (Cl.4.3.13.2), Human exposure to UV radiation (Cl.4.3.13.4), Type laser system only (Cl.4.3.13.5), Unattended Equipments (Cl. 5.3.8) |
| 69 |
Nextron International Lab Private Limited
| 9140226
| IS 13252 : Part 1 (2010) |
Information technology equipment - Safety: Part 1 general requirements (Second Revision) |
- |
50000 View breakup
Rs. 50,000/- (For each sample) Automatic data processing machine, Laptop/notebook/tablet, Printers, plotters, Scanners, set top box, Telephone answering machines, Visual display units, videos monitors of screen size 32" and above, Wireless keyboards, Cash registers, Copying machines /duplicators, Passport reader, point of sale terminals, Mail processing machines/postage machines/franking machines, Power banks for use in portable applications, smart card reader, Mobile phones, Power adaptors for it equipments, Visual display units, Video monitors of screen size upto 32’’ inch, CCTV cameras/CCTV recorders, USB driven barcode readers, barcode scanners, iris scanners, optical fingerprint scanners, Smart watches, Keyboard, automatic teller cash dispensing machines, USB type external hard disk drive, USB type external solid-state storage devices (above 256 Gb capacity), Standalone switch mode power supplies
(SMPS) with output voltage 48v (max), Digital camera, Smart speakers (with and without display). (10% discount to BIS)
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 1.5(Components) |
- |
1000 |
|
- |
| 1.6(Power interface .) |
- |
1500 |
|
- |
| 1.7(Markings and instructions) |
- |
400 |
|
- |
| 2.1(Protection from electric shock and energy hazards) |
- |
4000 |
|
- |
| 2.2(SELV circuits) |
- |
900 |
|
- |
| 2.3(TNV circuits) |
- |
1000 |
|
- |
| 2.4(Limited current circuits) |
- |
1400 |
|
- |
| 2.5(Limited power sources .) |
- |
400 |
|
- |
| 2.6(Provisions for earthing and bonding) |
- |
4000 |
|
- |
| 2.7(Overcurrent and earth fault protection in primary circuits) |
- |
4000 |
|
- |
| 2.8(Safety interlocks) |
- |
900 |
|
- |
| 2.9(Electrical insulation) |
- |
4000 |
|
- |
| 2.10(Clearances, creepage distances and distances through insulation) |
- |
2400 |
|
- |
| 3.1(General) |
- |
800 |
|
- |
| 3.2(Connection to a mains supply) |
- |
800 |
|
- |
| 3.3(Wiring terminals for connection of external conductors) |
- |
1500 |
|
- |
| 3.4(Disconnection from the mains supply) |
- |
800 |
|
- |
| 3.5(Interconnection of equipment) |
- |
800 |
|
- |
| 4.1(Stability) |
- |
800 |
|
- |
| 4.2(Mechanical strength) |
- |
800 |
|
- |
| 4.3(Design and construction) |
- |
800 |
|
- |
| 4.4(Protection against hazardous moving parts) |
- |
1000 |
|
- |
| 4.5(Thermal requirements) |
- |
3000 |
|
- |
| 4.6(Openings in enclosures) |
- |
1000 |
|
- |
| 4.7(Resistance to fire) |
- |
2000 |
|
- |
| 5.1(Touch current and protective conductor curren) |
- |
1000 |
|
- |
| 5.2(Electric strength) |
- |
2000 |
|
- |
| 5.3(Abnormal operating and fault conditions) |
- |
1000 |
|
- |
| 6.1(Protection of telecommunication network service persons, and users of other equipment connected to the network, from hazards in the equipment) |
- |
1500 |
|
- |
| 6.2(Protection of equipment users from overvoltages on networks telecommunication) |
- |
1500 |
|
- |
| 6.3(Protection of the telecommunication wiring system from overheating) |
- |
1000 |
|
- |
| 7.1(General) |
- |
1000 |
|
- |
| 7.2(Protection of cable distribution system service persons, and users of other equipment connected to the system, from hazardous voltages in the equipment) |
- |
1000 |
|
- |
| 7.3(Protection of equipment users from overvoltages on the cable distribution system) |
- |
1000 |
|
- |
| 7.4(Insulation between primary circuits and cable distribution systems) |
- |
600 |
|
- |
|
06 Jun, 2027 |
- Restricted Up to & including 300V AC, 50Hz and 150V DC.
Excluding: Component (Cl.1.5), TNV circuits (C1.2.3, annex-M), safety interlocks: moving parts (C1.2.8.5), Switches & relays (Cl.2.8.7), Semiconductor Devices (opto-coupler test) (Cl2.10.5.4), Insulation in wound components (Cl.2.10.5.11),
Wire in wound components (Cl.2.10.5.12), wire with solvent-based enamel In wound components (Cl.2.10.5.13), addi. Insulation in wound components (Cl.2.10.5.14), Construction for PCB (Cl.2.10.6), Components external termination (Cl.2.10.7), Tests on coated printed boards and coated
Components (Cl.2.10.8), thermal cycling (Cl.2.10.9), tests for pollution degree 1 Environment and for insulating compound (Cl.2.10.10), tests for semiconductor devices & for Cemented joints (Cl.2.10.11), enclosed & sealed Parts (Cl.2.10.12), appliance inlets (Cl. 3.2.4), AC Power supply cords (Cl. 3.2.5), cathode ray Tube (C1.4.2.8), high pressure lamps (C1.4.2.9), Batteries (Cl.4.3.8); oil and grease (C1.4.3.9), Dust, Powder, Liquids and gases (Cl.4.3.10), Containers for liquids and gases (Cl.4.3.11), Flammable Liquids (Cl.4.3.12), Radiation (C1.4.3.13), Hot flaming oil test (Cl.4.6.2 & Annex-A3), Test for Adhesive for constructional purpose (C1.4.6.5), Materials for components and other parts
But side fire enclosures (CI 4.7.3.3), Materials for components and other parts inside fire enclosures (CI 4.7.3.4), HV component material (C1.4.7.3.6), Motors (Cl.5.3.2), Transformers (CI.5.3.3). Electromechanical components (Cl.5.3.5), Simulation of faults (Cl. 5.3.7), Unattended equipment (Cl.5.3.8) Insulating winding wires (Annex U), Evaluation of IC current limiters (Annex CC). |
| 70 |
Aforeserve Labs Private Limited, Gurugram
| 9140626
| IS 13252 : Part 1 (2010) |
Information technology equipment - Safety: Part 1 general requirements (Second Revision) |
- |
35000 View breakup
Rs.35000/- for Wireless Key boards, Laptop/ Notebook/Tablets, Set top box, Visual display units (up to and including 32”), Printers, Scanners, Telephone answering machines, Automatic Data processing machines, Cash Registers, Smart Card Reader, Power adapter for IT equipment’s, Power Bank for use in portable applications, Mobile Phones, Copying machines, Mail Processing Machines, Visual Display Unit, Video monitors of screen size 32” and above up to 55”, Passport Reader, Point of Sale Terminal, CCTV Cameras/ CCTV Recorders, USB driven Barcode reader, Barcode Scanners, Iris Scanners, Optical fingerprint Scanner, Smart Watches, Keyboard, Automatic Teller Cash Dispensing Machine, USB type external hard disk drive, USB type external solid-state storage devices (above 256GB capacity), Standalone switch mode power supplies (SMPS) with output voltage 48 V (max), Digital Camera.[10% Discount to BIS ]
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 1.6(Power interface .) |
- |
5000 |
|
10% DISCOUNT TO BIS |
| 1.7(Markings and instructions) |
- |
1323 |
|
10% DISCOUNT TO BIS |
| 2.1(Protection from electric shock and energy hazards) |
- |
1028 |
|
10% DISCOUNT TO BIS |
| 2.2(SELV circuits) |
- |
1029 |
|
10% DISCOUNT TO BIS |
| 2.3(TNV circuits) |
- |
1029 |
|
10% DISCOUNT TO BIS |
| 2.4(Limited current circuits) |
- |
1029 |
|
10% DISCOUNT TO BIS |
| 2.5(Limited power sources .) |
- |
1029 |
|
10% DISCOUNT TO BIS |
| 2.6(Provisions for earthing and bonding) |
- |
1029 |
|
10% DISCOUNT TO BIS |
| 2.7(Overcurrent and earth fault protection in primary circuits) |
- |
1029 |
|
10% DISCOUNT TO BIS |
| 2.8(Safety interlocks) |
- |
1029 |
|
10% DISCOUNT TO BIS |
| 2.9(Electrical insulation) |
- |
1029 |
|
10% DISCOUNT TO BIS |
| 2.10(Clearances, creepage distances and distances through insulation) |
- |
1029 |
|
10% DISCOUNT TO BIS |
| 3.1(General) |
- |
1029 |
|
10% DISCOUNT TO BIS |
| 3.2(Connection to a mains supply) |
- |
1029 |
|
10% DISCOUNT TO BIS |
| 3.3(Wiring terminals for connection of external conductors) |
- |
1029 |
|
10% DISCOUNT TO BIS |
| 3.4(Disconnection from the mains supply) |
- |
1029 |
|
10% DISCOUNT TO BIS |
| 3.5(Interconnection of equipment) |
- |
1029 |
|
10% DISCOUNT TO BIS |
| 4.1(Stability) |
- |
1029 |
|
10% DISCOUNT TO BIS |
| 4.2(Mechanical strength) |
- |
1029 |
|
10% DISCOUNT TO BIS |
| 4.3(Design and construction) |
- |
1029 |
|
10% DISCOUNT TO BIS |
| 4.4(Protection against hazardous moving parts) |
- |
1029 |
|
10% DISCOUNT TO BIS |
| 4.5(Thermal requirements) |
- |
1029 |
|
10% DISCOUNT TO BIS |
| 4.6(Openings in enclosures) |
- |
1029 |
|
10% DISCOUNT TO BIS |
| 4.7(Resistance to fire) |
- |
1029 |
|
10% DISCOUNT TO BIS |
| 5.1(Touch current and protective conductor curren) |
- |
900 |
|
10% DISCOUNT TO BIS |
| 5.2(Electric strength) |
- |
900 |
|
10% DISCOUNT TO BIS |
| 5.3(Abnormal operating and fault conditions) |
- |
900 |
|
10% DISCOUNT TO BIS |
| 6.1(Protection of telecommunication network service persons, and users of other equipment connected to the network, from hazards in the equipment) |
- |
900 |
|
10% DISCOUNT TO BIS |
| 6.2(Protection of equipment users from overvoltages on networks telecommunication) |
- |
900 |
|
10% DISCOUNT TO BIS |
| 6.3(Protection of the telecommunication wiring system from overheating) |
- |
900 |
|
10% DISCOUNT TO BIS |
| 7.1(General) |
- |
900 |
|
10% DISCOUNT TO BIS |
| 7.2(Protection of cable distribution system service persons, and users of other equipment connected to the system, from hazardous voltages in the equipment) |
- |
900 |
|
10% DISCOUNT TO BIS |
| 7.3(Protection of equipment users from overvoltages on the cable distribution system) |
- |
900 |
|
10% DISCOUNT TO BIS |
| 7.4(Insulation between primary circuits and cable distribution systems) |
- |
1029 |
|
10% DISCOUNT TO BIS |
| 1.5(Components) |
- |
0 |
|
for component verification only |
|
06 Jun, 2027 |
- Additional products
included w.e.f.
02.04.2019
Component (Cl.1.5), Oil and grease (Cl.4.3.9), Flammable liquids (Cl. 4.3.12), Ionizing radiation (Cl.4.3.13.2), Effect of UV radiation on materials (Cl. 4.3.13.3), Human exposure to UV radiation (Cl.4.3.13.4), Laser including LED (Cl.4.3.13.5), Transformers (Cl.5.3.3) Electro mechanical components (Cl.5.3.5) |
| 71 |
KC INDIA TEST LABORATORIES LLP, GHAZIABAD
| 9140406
| IS 13252 : Part 1 (2010) |
Information technology equipment - Safety: Part 1 general requirements (Second Revision) |
- |
35000 View breakup
Laptop/ Notebook/ Tablet, Video monitors of screen size 32” & above, Printer, Plotter, Scanner, Visual display unit, Copying machines/ duplicators, Automatic data processing machine, Point of sale terminals & Cash Registers, Video monitors of screen size up to 32”, Smart Card Readers, Passport Reader, Banks for use in portable applications, Mobile phones, Wireless Keyboard/ Wired Keyboard, Set Top Box, Power adaptor for IT equipments, CCTV Cameras/ CCTV Recorders, Digital Camera. ADDITIONAL PRODUCTS INCLUDED W.E.F. 24-01-2022, mail processing machines / postage machines / franking machines / telephone answering machine= 35000/-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 1.6(Power interface .) |
- |
1300 |
|
breakup |
| 1.7(Markings and instructions) |
- |
650 |
|
breakup |
| 2.1(Protection from electric shock and energy hazards) |
- |
4550 |
|
breakup |
| 2.2(SELV circuits) |
- |
1625 |
|
breakup |
| 2.4(Limited current circuits) |
- |
1105 |
|
breakup |
| 2.5(Limited power sources .) |
- |
975 |
|
breakup |
| 2.6(Provisions for earthing and bonding) |
- |
1040 |
|
breakup |
| 2.7(Overcurrent and earth fault protection in primary circuits) |
- |
650 |
|
breakup |
| 2.8(Safety interlocks) |
- |
1625 |
|
breakup |
| 2.9(Electrical insulation) |
- |
3250 |
|
breakup |
| 2.10(Clearances, creepage distances and distances through insulation) |
- |
8255 |
|
breakup |
| 3.1(General) |
- |
3250 |
|
breakup |
| 3.2(Connection to a mains supply) |
- |
1300 |
|
breakup |
| 3.3(Wiring terminals for connection of external conductors) |
- |
1300 |
|
breakup |
| 3.4(Disconnection from the mains supply) |
- |
650 |
|
breakup |
| 3.5(Interconnection of equipment) |
- |
650 |
|
breakup |
| 4.1(Stability) |
- |
325 |
|
breakup |
| 4.2(Mechanical strength) |
- |
2080 |
|
breakup |
| 4.3(Design and construction) |
- |
650 |
|
breakup |
| 4.4(Protection against hazardous moving parts) |
- |
975 |
|
breakup |
| 4.5(Thermal requirements) |
- |
2990 |
|
breakup |
| 4.6(Openings in enclosures) |
- |
2925 |
|
breakup |
| 4.7(Resistance to fire) |
- |
2925 |
|
breakup |
| 5.1(Touch current and protective conductor curren) |
- |
845 |
|
breakup |
| 5.2(Electric strength) |
- |
1300 |
|
breakup |
| 5.3(Abnormal operating and fault conditions) |
- |
2600 |
|
breakup |
| 6.1(Protection of telecommunication network service persons, and users of other equipment connected to the network, from hazards in the equipment) |
- |
1300 |
|
breakup |
| 6.2(Protection of equipment users from overvoltages on networks telecommunication) |
- |
3055 |
|
breakup |
| 6.3(Protection of the telecommunication wiring system from overheating) |
- |
2600 |
|
breakup |
| 7.1(General) |
- |
650 |
|
breakup |
| 7.2(Protection of cable distribution system service persons, and users of other equipment connected to the system, from hazardous voltages in the equipment) |
- |
650 |
|
breakup |
| 7.3(Protection of equipment users from overvoltages on the cable distribution system) |
- |
2275 |
|
breakup |
| 7.4(Insulation between primary circuits and cable distribution systems) |
- |
2600 |
|
breakup |
|
06 Jun, 2027 |
- EXCLUSIONS: Component (Cl.1.5), Safety Interlocks: Moving parts (Cl.2.8.5), Switches & Relays (Cl.2.8.7),Semiconductor Devices (Opto-coupler test) (Cl.2.10.5.4), Insulation in wound components (Cl.2.10.5.11), Wire in wound components (Cl. 2.10.5.12), Tests for semiconductor devices & for cemented joints (Cl. 2.10.11), Cathode Ray Tube (Cl.4.2.8), Batteries (cl.4.3.8); Radiation (Cl.4.3.13), Electromechanical components (Cl. 5.3.5), Insulating winding wires (Annex U), Evaluation of IC current limiters (Annex CC). |
| 72 |
URS PRODUCTS AND TESTING PVT LTD (F3), NOIDA
| 8136826
| IS 13252 : Part 1 (2010) |
Information technology equipment - Safety: Part 1 general requirements (Second Revision) |
- |
60000 View breakup
Rs.60,000/- for Laptop/ notebook/ tablet, Printer & Plotters, Scanner, Power adaptor for IT equipments, Automatic data processing machine, Mobile phones and Mail processing machine/ postage machine/ Franking machine. Rs.52,500/- for Point of sale terminal, Copying machine/ duplicators, Passport Readers and Power bank for use in portable applications. Rs.45,000/- for Set Top Box, Telephone answering machine, Cash Registers and Smart card readers. Rs.40,000/- for Wireless Keyboard, Rs.50,000/- For VDU, Video Monitors of screen size up to 55” & Rs.60,000/- For upto 110", CCTV Cameras/ CCTV Recorder, USB driven Barcode Reader, Barcode scanner, Iris scanners, Optical Fingerprint scanner Rs.55,000/- Smart Watches Rs.35,000/- Keyboard, • Rs.45,000/- Automatic Teller Cash Dispensing Machines, Rs.35,000/- USB Type External Hard Disk Drive, Rs.35,000/- USB Type External Solid - State Storage Devices (above 256 GB Capacity), Rs.45,000/- Standalone Switch Mode Power Supplies (SMPS) with output voltage 48 V (max) . ADDITONAL PRODUCTS FOR PHASE V INCLUDED W.E.F. 19-11-2020: Rs.35,000/- for Digital Camera
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 1.5(Components) |
- |
1000 |
|
15 % Discount to BIS |
| 1.6(Power interface .) |
- |
2000 |
|
15 % Discount to BIS |
| 1.7(Markings and instructions) |
- |
500 |
|
15 % Discount to BIS |
| 2.1(Protection from electric shock and energy hazards) |
- |
4500 |
|
15 % Discount to BIS |
| 2.2(SELV circuits) |
- |
2000 |
|
15 % Discount to BIS |
| 2.3(TNV circuits) |
- |
1000 |
|
15 % Discount to BIS |
| 2.4(Limited current circuits) |
- |
2000 |
|
15 % Discount to BIS |
| 2.5(Limited power sources .) |
- |
2000 |
|
15 % Discount to BIS |
| 2.6(Provisions for earthing and bonding) |
- |
2000 |
|
15 % Discount to BIS |
| 2.7(Overcurrent and earth fault protection in primary circuits) |
- |
500 |
|
15 % Discount to BIS |
| 2.8(Safety interlocks) |
- |
1000 |
|
15 % Discount to BIS |
| 2.9(Electrical insulation) |
- |
3000 |
|
15 % Discount to BIS |
| 2.10(Clearances, creepage distances and distances through insulation) |
- |
1000 |
|
15 % Discount to BIS |
| 3.1(General) |
- |
1000 |
|
15 % Discount to BIS |
| 3.2(Connection to a mains supply) |
- |
1000 |
|
15 % Discount to BIS |
| 3.3(Wiring terminals for connection of external conductors) |
- |
1000 |
|
15 % Discount to BIS |
| 3.4(Disconnection from the mains supply) |
- |
500 |
|
15 % Discount to BIS |
| 3.5(Interconnection of equipment) |
- |
500 |
|
15 % Discount to BIS |
| 4.1(Stability) |
- |
500 |
|
15 % Discount to BIS |
| 4.2(Mechanical strength) |
- |
4000 |
|
15 % Discount to BIS |
| 4.3(Design and construction) |
- |
4000 |
|
15 % Discount to BIS |
| 4.4(Protection against hazardous moving parts) |
- |
2000 |
|
15 % Discount to BIS |
| 4.5(Thermal requirements) |
- |
3000 |
|
15 % Discount to BIS |
| 4.6(Openings in enclosures) |
- |
500 |
|
15 % Discount to BIS |
| 4.7(Resistance to fire) |
- |
5000 |
|
15 % Discount to BIS |
| 5.1(Touch current and protective conductor curren) |
- |
2000 |
|
15 % Discount to BIS |
| 5.2(Electric strength) |
- |
2000 |
|
15 % Discount to BIS |
| 5.3(Abnormal operating and fault conditions) |
- |
5000 |
|
15 % Discount to BIS |
| 6.1(Protection of telecommunication network service persons, and users of other equipment connected to the network, from hazards in the equipment) |
- |
1000 |
|
15 % Discount to BIS |
| 6.2(Protection of equipment users from overvoltages on networks telecommunication) |
- |
1000 |
|
15 % Discount to BIS |
| 6.3(Protection of the telecommunication wiring system from overheating) |
- |
500 |
|
15 % Discount to BIS |
| 7.1(General) |
- |
500 |
|
15 % Discount to BIS |
| 7.2(Protection of cable distribution system service persons, and users of other equipment connected to the system, from hazardous voltages in the equipment) |
- |
500 |
|
15 % Discount to BIS |
| 7.3(Protection of equipment users from overvoltages on the cable distribution system) |
- |
1000 |
|
15 % Discount to BIS |
| 7.4(Insulation between primary circuits and cable distribution systems) |
- |
1000 |
|
15 % Discount to BIS |
|
31 Dec, 2026 |
- Excluding: Capacitor
Bridging Insulation
(Cl.1.5.6), Resistor
Bridging Insulation
(Cl.1.5.7), Surge
Suppressor (Cl.1.5.9),
Mechanical strength of
Cathode Ray Tube
(Cl.4.2.8), Flammable
Liquid (Cl.4.3.12), Effect
of UV Radiation on
materials (Cl.4.3.13.3),
Human exposure to UV
radiation (Cl.4.3.13.4) &
Effect of lasers
(including LED)
(Cl.4.3.13.5).
Additional Products/
Test Facility included
w.e.f. 18.07.2018.
For rating up to 300V,
1Φ, AC |
| 73 |
Ace Test Labs & Metrology Pvt. Ltd., Sonipat
| 9162826
| IS 13252 : Part 1 (2010) |
Information technology equipment - Safety: Part 1 general requirements (Second Revision) |
- |
120800 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 1.6(Power interface .) |
- |
3000 |
|
10% discount for BIS |
| 1.7(Markings and instructions) |
- |
1000 |
|
10% discount for BIS |
| 2.1(Protection from electric shock and energy hazards) |
- |
5000 |
|
10% discount for BIS |
| 2.2(SELV circuits) |
- |
5500 |
|
10% discount for BIS |
| 2.3(TNV circuits) |
- |
6000 |
|
10% discount for BIS |
| 2.4(Limited current circuits) |
- |
3000 |
|
10% discount for BIS |
| 2.5(Limited power sources .) |
- |
3000 |
|
10% discount for BIS |
| 2.6(Provisions for earthing and bonding) |
- |
3000 |
|
10% discount for BIS |
| 2.9(Electrical insulation) |
- |
800 |
|
800/hr , 10% discount for BIS |
| 2.10(Clearances, creepage distances and distances through insulation) |
- |
4000 |
|
10% discount for BIS |
| 3.2(Connection to a mains supply) |
- |
4000 |
|
10% discount for BIS |
| 3.3(Wiring terminals for connection of external conductors) |
- |
4000 |
|
10% discount for BIS |
| 3.5(Interconnection of equipment) |
- |
4000 |
|
10% discount for BIS |
| 4.1(Stability) |
- |
3000 |
|
10% discount for BIS |
| 4.2(Mechanical strength) |
- |
4000 |
|
10% discount for BIS |
| 4.3(Design and construction) |
- |
5000 |
|
10% discount for BIS |
| 4.4(Protection against hazardous moving parts) |
- |
6000 |
|
10% discount for BIS |
| 4.5(Thermal requirements) |
- |
6000 |
|
10% discount for BIS |
| 4.6(Openings in enclosures) |
- |
3000 |
|
10% discount for BIS |
| 4.7(Resistance to fire) |
- |
6000 |
|
10% discount for BIS |
| 5.1(Touch current and protective conductor curren) |
- |
3000 |
|
10% discount for BIS |
| 5.2(Electric strength) |
- |
5000 |
|
10% discount for BIS |
| 5.3(Abnormal operating and fault conditions) |
- |
8000 |
|
for 8 hr, 10% discount for BIS |
| 6.1(Protection of telecommunication network service persons, and users of other equipment connected to the network, from hazards in the equipment) |
- |
3000 |
|
10% discount for BIS |
| 6.2(Protection of equipment users from overvoltages on networks telecommunication) |
- |
3000 |
|
10% discount for BIS2000 |
| 6.3(Protection of the telecommunication wiring system from overheating) |
- |
4000 |
|
10% discount for BIS |
| 7.2(Protection of cable distribution system service persons, and users of other equipment connected to the system, from hazardous voltages in the equipment) |
- |
4000 |
|
10% discount for BIS |
| 7.3(Protection of equipment users from overvoltages on the cable distribution system) |
- |
2000 |
|
10% discount for BIS |
| 7.4(Insulation between primary circuits and cable distribution systems) |
- |
2000 |
|
10% discount for BIS |
| 2.7(Overcurrent and earth fault protection in primary circuits) |
- |
1000 |
|
10% discount for BIS |
| 3.1(General) |
- |
1000 |
|
10% discount for BIS |
| 3.4(Disconnection from the mains supply) |
- |
500 |
|
10% discount for BIS |
|
14 Nov, 2027 |
- Exclusions: Components (Cl.1.5), Safety Interlocks (Cl.2.8), Semiconductor devices (Cl.2.10.5.4), AC Power Supply Cord (Cl.3.2.5.1), Cathode ray tubes (Cl.4.2.8 ), High pressure lamps (Cl.4.2.9), Ionizing radiation (Cl.4.3.13.2), Effect of ultraviolet UV radiations on materials (Cl.4.3.13.3), Human exposure to ultraviolet radiations (Cl.4.3.13.4), Lasers (including LEDs) (Cl.4.3.13.5), Insulating winding wires (Annex-U), Evaluation of IC current limiters (Annex CC) |