| 31 |
REACT COMPLIANCE AND TESTING LABORATORIES LLP, BENGALURU
| 6130526
| IS 16242 : Part 1 (2014) |
Uninterruptible power systems (UPS): Part 1 general and safety requirements for UPS |
- |
65000 View breakup
UPS / Inverters of rating ≤ 5KVA- Rs. 55,000/-, UPS / Inverters of rating > 5KVA and ≤ 10KVA- Rs. 65,000/-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4.5(Components) |
- |
1500 |
|
- |
| 4.6(Power interface) |
- |
1500 |
|
- |
| 4.7(Marking & instructions) |
- |
3000 |
|
- |
| 5.1(Protection against shock and energy hazards) |
- |
3000 |
|
- |
| 5.2(Requirement of auxiliary circuits) |
- |
10000 |
|
- |
| 5.3(Protective earthing and bonding) |
- |
3000 |
|
- |
| 5.4(AC and DC power isolation) |
- |
1500 |
|
- |
| 5.5(Over current and earth fault condition) |
- |
1500 |
|
- |
| 5.6(Safety interlocks) |
- |
1500 |
|
- |
| 5.7(CLEARANCES, CREEPAGE DISTANCES AND SOLID INSULATION) |
- |
4000 |
|
- |
| 6.1(Wiring, connections and supply) |
- |
1500 |
|
- |
| 6.2(Connection to power) |
- |
1500 |
|
- |
| 6.3(Wiring terminals for external power conductors) |
- |
1500 |
|
- |
| 7.1(Enclosure) |
- |
1500 |
|
- |
| 7.2(STABILITY) |
- |
1500 |
|
- |
| 7.3(MECHANICAL STRENGTH) |
- |
5500 |
|
- |
| 7.4(Construction details) |
- |
1500 |
|
- |
| 7.5(Resistance to fire) |
- |
1500 |
|
- |
| 7.6(Battery location) |
- |
1500 |
|
- |
| 7.7(Temperature rise) |
- |
1500 |
|
- |
| 8.1(General procision for earth leakage) |
- |
1500 |
|
- |
| 8.2(Electric Strength) |
- |
1500 |
|
- |
| 8.3(Abnormal operating and fault conditions) |
- |
5000 |
|
- |
| 9.0(Connection to telecommunication networks) |
- |
4000 |
|
- |
|
10 Mar, 2027 |
- IS Included w.e.f. 13/3/2018
Excluding following tests:
Components (cl.4.5/RD 1.5);
Moving parts (cl.5.6/RD 2.8.5);
Overload test (cl.5.6/RD 2.8.7.2);
Endurance test (cl.5.6/RD 2.8.7.3);
Semi-conductor devices (cl.5.7/RD 2.10.5.4);
Insulation in wound components
(cl.5.7/RD 2.10.5.11);
Construction of printed circuit boards (cl.5.7/RD/ 2.10.6);
Test on coated printed boards and coated components (cl.5.7/RD 2.10.8);
Thermal cycling (cl.5.7/ RD 2.10.9);
Test for pollution degree 1 environment and for insulating components (cl.5.7/RD 2.10.10);
Enclosed sealing parts (cl.5.7/RD 2.10.12);
Resistance to fire-Flammability test (cl.7.5, Annex A);
Ventilation (cl. 7.6.7 & Annex M) |
| 32 |
Electrical Research and Development Association (ERDA), Vadodara, Gujarat
| 7101125
| IS 16242 : Part 1 (2014) |
Uninterruptible power systems (UPS): Part 1 general and safety requirements for UPS |
Capacity up to 10 kVA. |
95000 View breakup
Rs. 95,000/- (Upto and including 10kVA)
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4.5(Components) |
- |
3000 |
|
--- |
| 4.6(Power interface) |
- |
5000 |
|
--- |
| 4.7(Marking & instructions) |
- |
3300 |
|
--- |
| 5.1(Protection against shock and energy hazards) |
- |
26700 |
|
Test charge for cl. no. 5 is Rs. 26700/- |
| 5.2(Requirement of auxiliary circuits) |
- |
0 |
|
Test charge for cl. no. 5 is Rs. 26700/- |
| 5.3(Protective earthing and bonding) |
- |
0 |
|
Test charge for cl. no. 5 is Rs. 26700/- |
| 5.4(AC and DC power isolation) |
- |
0 |
|
Test charge for cl. no. 5 is Rs. 26700/- |
| 5.5(Over current and earth fault condition) |
- |
0 |
|
Test charge for cl. no. 5 is Rs. 26700/- |
| 5.6(Safety interlocks) |
- |
0 |
|
Test charge for cl. no. 5 is Rs. 26700/- |
| 5.7(CLEARANCES, CREEPAGE DISTANCES AND SOLID INSULATION) |
- |
0 |
|
Test charge for cl. no. 5 is Rs. 26700/- |
| 6.1(Wiring, connections and supply) |
- |
15000 |
|
Test charge for cl. no. 6 is Rs. 15000/- |
| 6.2(Connection to power) |
- |
0 |
|
Test charge for cl. no. 6 is Rs. 15000/- |
| 6.3(Wiring terminals for external power conductors) |
- |
0 |
|
Test charge for cl. no. 6 is Rs. 15000/- |
| 7.1(Enclosure) |
- |
20000 |
|
Test charge for cl. no. 7 is Rs. 20000/- |
| 7.2(STABILITY) |
- |
0 |
|
Test charge for cl. no. 7 is Rs. 20000/- |
| 7.3(MECHANICAL STRENGTH) |
- |
0 |
|
Test charge for cl. no. 7 is Rs. 20000/- |
| 7.4(Construction details) |
- |
0 |
|
Test charge for cl. no. 7 is Rs. 20000/- |
| 7.5(Resistance to fire) |
- |
0 |
|
Test charge for cl. no. 7 is Rs. 20000/- |
| 7.6(Battery location) |
- |
0 |
|
Test charge for cl. no. 7 is Rs. 20000/- |
| 7.7(Temperature rise) |
- |
0 |
|
Test charge for cl. no. 7 is Rs. 20000/- |
| 8.1(General procision for earth leakage) |
- |
22000 |
|
Test charge for cl. no. 8 is Rs. 22000/- |
| 8.2(Electric Strength) |
- |
0 |
|
Test charge for cl. no. 8 is Rs. 22000/- |
| 8.3(Abnormal operating and fault conditions) |
- |
0 |
|
Test charge for cl. no. 8 is Rs. 22000/- |
| 9.0(Connection to telecommunication networks) |
- |
0 |
|
Test charge for cl. no. 8 is Rs. 22000/- |
| Annex I.5(Solid-state backfeed protection) |
- |
0 |
|
--- |
| I.5(transient overvoltages) |
- |
0 |
|
--- |
| I.5(voltage variations) |
- |
0 |
|
--- |
| I.5(electromagnetic susceptibility) |
- |
0 |
|
--- |
| I.5(electrostatic discharge) |
- |
0 |
|
--- |
|
30 Nov, 2028 |
- Exclusion: Cl. 4.5/RD 1.5 (Components), Cl. 2.10.6 (PCB Material), Cl. 2.10.5.4 (Semiconductor devices), Cl. 2.10.5.6 (Thin sheet material) |
| 33 |
Hi Physix Laboratory India Private Limited, Pune
| 7126926
| IS 16242 : Part 1 (2014) |
Uninterruptible power systems (UPS): Part 1 general and safety requirements for UPS |
- |
190000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4.6(Power interface) |
- |
15000 |
|
- |
| 4.7(Marking & instructions) |
- |
3000 |
|
- |
| 5.1(Protection against shock and energy hazards) |
- |
5000 |
|
- |
| 5.2(Requirement of auxiliary circuits) |
- |
10000 |
|
- |
| 5.3(Protective earthing and bonding) |
- |
5000 |
|
- |
| 5.4(AC and DC power isolation) |
- |
3000 |
|
- |
| 5.5(Over current and earth fault condition) |
- |
5000 |
|
- |
| 5.6(Safety interlocks) |
- |
5000 |
|
- |
| 5.7(CLEARANCES, CREEPAGE DISTANCES AND SOLID INSULATION) |
- |
5000 |
|
- |
| 6.1(Wiring, connections and supply) |
- |
3000 |
|
- |
| 6.2(Connection to power) |
- |
5000 |
|
- |
| 6.3(Wiring terminals for external power conductors) |
- |
5000 |
|
- |
| 7.1(Enclosure) |
- |
5000 |
|
- |
| 7.2(STABILITY) |
- |
5000 |
|
- |
| 7.3(MECHANICAL STRENGTH) |
- |
5000 |
|
- |
| 7.4(Construction details) |
- |
5000 |
|
- |
| 7.5(Resistance to fire) |
- |
5000 |
|
- |
| 7.6(Battery location) |
- |
8000 |
|
- |
| 7.7(Temperature rise) |
- |
5000 |
|
- |
| 8.1(General procision for earth leakage) |
- |
5000 |
|
- |
| 8.2(Electric Strength) |
- |
3000 |
|
- |
| 8.3(Abnormal operating and fault conditions) |
- |
5000 |
|
- |
| 9.0(Connection to telecommunication networks) |
- |
10000 |
|
- |
| 4.5(Components) |
- |
5000 |
|
- |
| Annex I.5(Solid-state backfeed protection) |
- |
55000 |
|
Charges applicable for Cl. I.5 Solid state back feed protection (ESD tests, Radio frequency electromagnetic field test, Fast transient burst test, Surge test, conducted radio frequency commen mode test, Immunity to power frequency magnetic field test) |
|
20 Jun, 2028 |
- Excluding following
tests: Thermal Controls
Test (Cl. 4.5 (Cl. 1.5.3
of RD)), Capacitor
Bridging Insulation (Cl.
4.5 (Cl. 1.5.6 of RD)),
Components in
Equipment for IT Power
Distribution Systems
(Cl. 4.5 (Cl. 1.5.8 of
RD)), Safety Interlocks
(Cl. 5.6 (Cl. 2.8.5, Cl.
2.8.7 of RD)),
Semiconductor Devices
(Only Opto-coupler
tests as per IEC 60747-
5-5) (Cl. 5.7 (Cl.
2.10.5.4 of RD)),
Construction of Printed
Boards (Except
Dimensional
Measurement) (Cl. 5.7
(Cl. 2.10.6 of RD)),
Component External
Terminations (Except
Dimensional
Measurement) (Cl. 5.7
(Cl. 2.10.7 of RD)),
Tests on Coated Printed
Boards and Coated
Components (Except
Dimension
Measurement) (Cl.
5.7(Cl. 2.10.8 of RD)),
AC Power Supply Cords
(Except Cross
Sectional area of cable
/cords) (Cl. 6.2.2 (Cl.
3.2.5.1 of RD)),
Cathode Ray Tube (Cl.
7.3 (Cl. 4.2.8 RD)),
Solid state back feed protection (ESD tests, Radio frequency electromagnetic field test, Fast transient burst test, Surge test, conducted radio frequency commen mode test, Immunity to low frequency signal test, Immunity to power frequency magnetic field test), Insulating
Winding Wire for use
without Interleaved
Insulation (Annex U of
RD) and Evaluation of
Integrated Circuit (IC)
Current Limiter (Annex
CC of RD). |
| 34 |
AA Electro Magnetic Laboratory Pvt Ltd, Gurugram
| 8165826
| IS 16242 : Part 1 (2014) |
Uninterruptible power systems (UPS): Part 1 general and safety requirements for UPS |
- |
75000 View breakup
Rs.65,000/- for UPS/Inverters upto 2 kVA
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4.6(Power interface) |
- |
5000 |
|
Charges are excluding BIS samples |
| 4.7(Marking & instructions) |
- |
2000 |
|
Charges are excluding BIS samples |
| 5.1(Protection against shock and energy hazards) |
- |
5000 |
|
Charges are excluding BIS samples |
| 5.2(Requirement of auxiliary circuits) |
- |
5000 |
|
Charges are excluding BIS samples |
| 5.3(Protective earthing and bonding) |
- |
3000 |
|
Charges are excluding BIS samples |
| 5.4(AC and DC power isolation) |
- |
2000 |
|
Charges are excluding BIS samples |
| 5.5(Over current and earth fault condition) |
- |
3000 |
|
Charges are excluding BIS samples |
| 5.6(Safety interlocks) |
- |
5000 |
|
Charges are excluding BIS samples |
| 5.7(CLEARANCES, CREEPAGE DISTANCES AND SOLID INSULATION) |
- |
5000 |
|
Charges are excluding BIS samples |
| 6.1(Wiring, connections and supply) |
- |
3000 |
|
Charges are excluding BIS samples |
| 6.2(Connection to power) |
- |
3000 |
|
Charges are excluding BIS samples |
| 6.3(Wiring terminals for external power conductors) |
- |
3000 |
|
Charges are excluding BIS samples |
| 7.1(Enclosure) |
- |
2000 |
|
Charges are excluding BIS samples |
| 7.2(STABILITY) |
- |
3000 |
|
Charges are excluding BIS samples |
| 7.3(MECHANICAL STRENGTH) |
- |
5000 |
|
Charges are excluding BIS samples |
| 7.4(Construction details) |
- |
5000 |
|
Charges are excluding BIS samples |
| 7.5(Resistance to fire) |
- |
3000 |
|
Charges are excluding BIS samples |
| 7.6(Battery location) |
- |
5000 |
|
Charges are excluding BIS samples |
| 7.7(Temperature rise) |
- |
4000 |
|
Charges are excluding BIS samples |
| 8.1(General procision for earth leakage) |
- |
3000 |
|
Charges are excluding BIS samples |
| 8.2(Electric Strength) |
- |
3000 |
|
Charges are excluding BIS samples |
| 8.3(Abnormal operating and fault conditions) |
- |
5000 |
|
Charges are excluding BIS samples |
| 9.0(Connection to telecommunication networks) |
- |
3000 |
|
Charges are excluding BIS samples |
| Annex I.5(Solid-state backfeed protection) |
- |
0 |
|
NA |
| I.5(transient overvoltages) |
- |
0 |
|
NA |
|
24 Sep, 2026 |
- Single Phase only. Restricted upto and including 5 kVA
Excluding:
Components (Cl.4.5) |
| 35 |
IEC TEST LABS LLP
| 8165726
| IS 16242 : Part 1 (2014) |
Uninterruptible power systems (UPS): Part 1 general and safety requirements for UPS |
- |
50000 View breakup
Rs.50000/-(20% discount to BIS).
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4.5(Components) |
- |
1500 |
|
- |
| 4.6(Power interface) |
- |
3000 |
|
- |
| 4.7(Marking & instructions) |
- |
1500 |
|
- |
| 5.1(Protection against shock and energy hazards) |
- |
2000 |
|
- |
| 5.2(Requirement of auxiliary circuits) |
- |
2000 |
|
- |
| 5.3(Protective earthing and bonding) |
- |
2000 |
|
- |
| 5.4(AC and DC power isolation) |
- |
2000 |
|
- |
| 5.5(Over current and earth fault condition) |
- |
2000 |
|
- |
| 5.6(Safety interlocks) |
- |
1000 |
|
- |
| 5.7(CLEARANCES, CREEPAGE DISTANCES AND SOLID INSULATION) |
- |
1500 |
|
- |
| 6.1(Wiring, connections and supply) |
- |
1500 |
|
- |
| 6.2(Connection to power) |
- |
1500 |
|
- |
| 6.3(Wiring terminals for external power conductors) |
- |
1000 |
|
- |
| 7.1(Enclosure) |
- |
2000 |
|
- |
| 7.2(STABILITY) |
- |
2500 |
|
- |
| 7.3(MECHANICAL STRENGTH) |
- |
1500 |
|
- |
| 7.4(Construction details) |
- |
1500 |
|
- |
| 7.5(Resistance to fire) |
- |
1000 |
|
- |
| 7.6(Battery location) |
- |
1000 |
|
- |
| 7.7(Temperature rise) |
- |
3000 |
|
- |
| 8.1(General procision for earth leakage) |
- |
2500 |
|
- |
| 8.2(Electric Strength) |
- |
3000 |
|
- |
| 8.3(Abnormal operating and fault conditions) |
- |
3000 |
|
- |
| 9.0(Connection to telecommunication networks) |
- |
1000 |
|
- |
| 4.5/RD 1.5(Components) |
- |
500 |
|
- |
| 2.10.5.11(SMPS/Main transformer) |
- |
500 |
|
- |
| 2.10.6(PCB Material) |
- |
500 |
|
- |
| 3.2.5(Non-rewirable plug with PVC sheathed cable) |
- |
500 |
|
- |
| 3.2.4(Appliances inlets/connectors) |
- |
500 |
|
- |
| 2.10.5.4(Semiconductor devices) |
- |
500 |
|
- |
| 2.10.5.13(Winding wires) |
- |
500 |
|
- |
| 4.3.8(Batteries) |
- |
500 |
|
- |
| 2.10.5.6(Thin sheet material) |
- |
500 |
|
- |
| 5.6.1/ RD 2.8.7(Switches & Relays) |
- |
500 |
|
- |
| 6.1.1/ RD 3.1.4(Insulating Conductors) |
- |
500 |
|
- |
|
07 Sep, 2026 |
- Included w.e.f. 11-01-2022. Exclusions: components (Cl.4.5/ RD, Cl.1.5), Safety interlocks- Moving Parts (Cl. 2.8.5 of RD), Switches & Relays- overload test ( Cl. 2.8.7.2 of RD), Swithces & Relays – Endurance test (Cl.2.8.7.3 of RD), (Annex U) Insulated winding wires , Insulating compound as solid insulation (Cl. 2.10.5.3 of RD), Semiconductor devices ( Cl.2.10.5.4 of RD), SMPS/Mains Transformer (Cl 2.10.5.11 of RD), Construction of printed Boards (Cl. 2.10.6 of RD), Power Supply Cords (Cl. 3.2.5 of RD) & Batteries (Cl.4.3.8) |
| 36 |
MARQUIS TECHNOLOGIES PRIVATE LIMITED, NOIDA
| 8175126
| IS 16242 : Part 1 (2014) |
Uninterruptible power systems (UPS): Part 1 general and safety requirements for UPS |
- |
50000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4.5(Components) |
- |
2000 |
|
- |
| 4.6(Power interface) |
- |
3000 |
|
- |
| 4.7(Marking & instructions) |
- |
2000 |
|
- |
| 5.1(Protection against shock and energy hazards) |
- |
3000 |
|
- |
| 5.2(Requirement of auxiliary circuits) |
- |
2000 |
|
- |
| 5.3(Protective earthing and bonding) |
- |
2000 |
|
- |
| 5.4(AC and DC power isolation) |
- |
4000 |
|
- |
| 5.5(Over current and earth fault condition) |
- |
3000 |
|
- |
| 5.6(Safety interlocks) |
- |
4000 |
|
- |
| 5.7(CLEARANCES, CREEPAGE DISTANCES AND SOLID INSULATION) |
- |
4000 |
|
- |
| 6.1(Wiring, connections and supply) |
- |
3000 |
|
- |
| 6.2(Connection to power) |
- |
3000 |
|
- |
| 6.3(Wiring terminals for external power conductors) |
- |
3000 |
|
- |
| 7.1(Enclosure) |
- |
2000 |
|
- |
| 7.2(STABILITY) |
- |
2000 |
|
- |
| 7.3(MECHANICAL STRENGTH) |
- |
5000 |
|
- |
| 7.4(Construction details) |
- |
5000 |
|
- |
| 7.5(Resistance to fire) |
- |
5000 |
|
- |
| 7.6(Battery location) |
- |
2000 |
|
- |
| 7.7(Temperature rise) |
- |
5000 |
|
- |
| 8.1(General procision for earth leakage) |
- |
5000 |
|
- |
| 8.2(Electric Strength) |
- |
5000 |
|
- |
| 8.3(Abnormal operating and fault conditions) |
- |
5000 |
|
- |
| 9.0(Connection to telecommunication networks) |
- |
10000 |
|
- |
|
13 Dec, 2026 |
- Exclusion: Cl. 4.5/RD 1.5 (Components), Cl. 2.10.5.4 (Semiconductor devices), Cl. 2.10.5.13 (Winding wires), Cl. 2.10.5.11 (SMPS/Main transformer), Cl. 2.10.6 (PCB Material), Annex I.5 (Solid-state backfeed protection), Cl.I.5 (transient overvoltages, voltage variations, electromagnetic susceptibility, electrostatic discharge) |
| 37 |
National Research and Technology Consortium (NRTC), Parwanoo
| 9136024
| IS 16242 : Part 1 (2014) |
Uninterruptible power systems (UPS): Part 1 general and safety requirements for UPS |
- |
47600 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4.6(Power interface) |
- |
0.0 |
|
Test Charges for this clause is included |
| 4.7(Marking & instructions) |
- |
0.0 |
|
Test Charges for this clause is included |
| 5.1(Protection against shock and energy hazards) |
- |
0.0 |
|
Test Charges for this clause is included |
| 5.2(Requirement of auxiliary circuits) |
- |
0.0 |
|
Test Charges for this clause is included |
| 5.3(Protective earthing and bonding) |
- |
0.0 |
|
Test Charges for this clause is included |
| 5.4(AC and DC power isolation) |
- |
0.0 |
|
Test Charges for this clause is included |
| 5.5(Over current and earth fault condition) |
- |
0.0 |
|
Test Charges for this clause is included |
| 5.6(Safety interlocks) |
- |
0 |
|
Test Charges for this clause is included |
| 5.7(CLEARANCES, CREEPAGE DISTANCES AND SOLID INSULATION) |
- |
0.0 |
|
Test Charges for this clause is included |
| 6.1(Wiring, connections and supply) |
- |
0.0 |
|
Test Charges for this clause is included |
| 6.2(Connection to power) |
- |
0.0 |
|
Test Charges for this clause is included |
| 6.3(Wiring terminals for external power conductors) |
- |
0.0 |
|
Test Charges for this clause is included |
| 7.1(Enclosure) |
- |
0.0 |
|
Test Charges for this clause is included |
| 7.2(STABILITY) |
- |
0.0 |
|
Test Charges for this clause is included |
| 7.3(MECHANICAL STRENGTH) |
- |
0.0 |
|
Test Charges for this clause is included |
| 7.4(Construction details) |
- |
0.0 |
|
Test Charges for this clause is included |
| 7.5(Resistance to fire) |
- |
0.0 |
|
Test Charges for this clause is included |
| 7.6(Battery location) |
- |
0.0 |
|
Test Charges for this clause is included |
| 7.7(Temperature rise) |
- |
0.0 |
|
Test Charges for this clause is included |
| 8.1(General procision for earth leakage) |
- |
0.0 |
|
Test Charges for this clause is included |
| 8.2(Electric Strength) |
- |
0.0 |
|
Test Charges for this clause is included |
| 8.3(Abnormal operating and fault conditions) |
- |
0.0 |
|
Test Charges for this clause is included |
| 9.0(Connection to telecommunication networks) |
- |
0.0 |
|
Test Charges for this clause is included |
|
10 Apr, 2026 |
- Up to 50Hz only
For UPS/Inverter up to 10 KVA)
Excluding Cl.3.3.3, Annex-L.5 - Non- linear loads
Cl.4.5- Components
Cl.5.6- Protection of Personnel-Safety Interlocks
Cl.6.2.1 /RD Cl.3.2.6.1-Power supply cords
Cl.7.6.7, Annex M- Gas Concentration, Ventilation of Battery Compartments
Annex I.5-Solid State back feed protection |
| 38 |
Vardhamana Testing Laboratory OPC Pvt. Ltd.
| 8178226
| IS 16242 : Part 1 (2014) |
Uninterruptible power systems (UPS): Part 1 general and safety requirements for UPS |
- |
40000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4.6(Power interface) |
- |
3000 |
|
- |
| 4.7(Marking & instructions) |
- |
1000 |
|
- |
| 5.1(Protection against shock and energy hazards) |
- |
1000 |
|
- |
| 5.2(Requirement of auxiliary circuits) |
- |
1000 |
|
- |
| 5.3(Protective earthing and bonding) |
- |
1000 |
|
- |
| 5.5(Over current and earth fault condition) |
- |
1000 |
|
- |
| 5.6(Safety interlocks) |
- |
3000 |
|
- |
| 5.7(CLEARANCES, CREEPAGE DISTANCES AND SOLID INSULATION) |
- |
2000 |
|
- |
| 6.2(Connection to power) |
- |
1000 |
|
- |
| 7.2(STABILITY) |
- |
1000 |
|
- |
| 7.4(Construction details) |
- |
1000 |
|
- |
| 7.5(Resistance to fire) |
- |
2000 |
|
- |
| 7.7(Temperature rise) |
- |
3000 |
|
- |
| 8.1(General procision for earth leakage) |
- |
1000 |
|
- |
| 8.2(Electric Strength) |
- |
1000 |
|
- |
| 8.3(Abnormal operating and fault conditions) |
- |
2000 |
|
- |
| 5.4(AC and DC power isolation) |
- |
2000 |
|
- |
| 7.1(Enclosure) |
- |
1000 |
|
- |
| 7.3(MECHANICAL STRENGTH) |
- |
1000 |
|
- |
| 6.1(Wiring, connections and supply) |
- |
1000 |
|
- |
| 6.3(Wiring terminals for external power conductors) |
- |
1000 |
|
- |
| 7.6(Battery location) |
- |
1000 |
|
- |
| 9.0(Connection to telecommunication networks) |
- |
2000 |
|
- |
| 2.10.5.13(Winding wires) |
- |
1000 |
|
- |
| 5.6.1/ RD 2.8.7(Switches & Relays) |
- |
1000 |
|
- |
| 6.1.1/ RD 3.1.4(Insulating Conductors) |
- |
1000 |
|
- |
| Annex I.5(Solid-state backfeed protection) |
- |
1000 |
|
- |
| I.5(transient overvoltages) |
- |
2000 |
|
- |
|
29 Apr, 2027 |
- Exclusion: Cl. 1.5 (Components), Cl. 2.10.6 (PCB Material), Cl. 3.2.5 (Non-rewirable plug with PVC sheathed cable), Cl. 3.2.4 (Appliances inlets/connectors), Cl. 2.10.5.4 (Semiconductor devices), Cl. 2.10.11 of RD (Tests for semiconductor devices and for cemented joints), Cl. 2.10.9 of RD (Thermal cycling), Cl. 2.10.10 of RD (Test for Pollution Degree 1 environment and for insulating compound), Cl. 4.3.8 (Batteries), CL. I.5 (electromagnetic susceptibility), Cl. I.5 (electrostatic discharge), Cl. 2.10.5.11 (SMPS/Main transformer), Cl. 4.5 (Components), Cl. 2.10.8 of RD (Tests on coated printed boards and coated components), Cl. 2.10.5.6 (Thin sheet material), Cl. Annex M (Ventilation of battery compartments), Cl. I.5 (voltage variations), Cl. Annex I.5 (Solid-state backfeed protection), Cl. I.5 (transient overvoltages), Cl. 2.10.5.13 (Winding wires) |
| 39 |
ATCC TEST LABS LLP
| 8172626
| IS 16242 : Part 1 (2014) |
Uninterruptible power systems (UPS): Part 1 general and safety requirements for UPS |
- |
30000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4.5(Components) |
- |
1000 |
|
- |
| 4.6(Power interface) |
- |
2500 |
|
- |
| 4.7(Marking & instructions) |
- |
1000 |
|
- |
| 5.1(Protection against shock and energy hazards) |
- |
2000 |
|
- |
| 5.2(Requirement of auxiliary circuits) |
- |
2000 |
|
- |
| 5.3(Protective earthing and bonding) |
- |
3000 |
|
- |
| 5.4(AC and DC power isolation) |
- |
2500 |
|
- |
| 5.5(Over current and earth fault condition) |
- |
3000 |
|
- |
| 5.6(Safety interlocks) |
- |
2500 |
|
- |
| 5.7(CLEARANCES, CREEPAGE DISTANCES AND SOLID INSULATION) |
- |
3000 |
|
- |
| 6.1(Wiring, connections and supply) |
- |
3000 |
|
- |
| 6.2(Connection to power) |
- |
2000 |
|
- |
| 6.3(Wiring terminals for external power conductors) |
- |
2000 |
|
- |
| 7.1(Enclosure) |
- |
2500 |
|
- |
| 7.2(STABILITY) |
- |
2000 |
|
- |
| 7.3(MECHANICAL STRENGTH) |
- |
1000 |
|
- |
| 7.4(Construction details) |
- |
500 |
|
- |
| 7.5(Resistance to fire) |
- |
1000 |
|
- |
| 7.6(Battery location) |
- |
1000 |
|
- |
| 7.7(Temperature rise) |
- |
2000 |
|
- |
| 8.1(General procision for earth leakage) |
- |
1000 |
|
- |
| 8.2(Electric Strength) |
- |
2500 |
|
- |
| 8.3(Abnormal operating and fault conditions) |
- |
2000 |
|
- |
| 9.0(Connection to telecommunication networks) |
- |
1000 |
|
- |
| 3.2.4(Appliances inlets/connectors) |
- |
1000 |
|
- |
|
15 Jun, 2026 |
- Exclusion: Components (Cl.4.5/RD, Cl.1.5), Semiconductor devices (Cl.2.10.5.4), Tests for semiconductor devices & cemented joints (Cl.2.10.11), Batteries (Cl.4.3.18), AC power cords (Cl.6.2.1/RD Cl.3.2.6.1), Non-rewirable plug with PVC sheathed cable (Cl.3.2.5), Power supply cords (Cl.3.2.5 of RD) & Solid state back –feed protection (EMC tests) (Annex 1.5), Performance test: simulators (ESD/EFT/Voltage dip interruption/PFMF), Scope restricted to all types of UPS up to 10 kVA. |
| 40 |
Classic Instrumentation Pvt. Ltd. (8135126), Noida
| 8135126
| IS 16242 : Part 1 (2014) |
Uninterruptible power systems (UPS): Part 1 general and safety requirements for UPS |
- |
35000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4.5(Components) |
- |
2000 |
|
20% discount to BIS |
| 4.6(Power interface) |
- |
2000 |
|
20% discount to BIS |
| 4.7(Marking & instructions) |
- |
2000 |
|
20% discount to BIS |
| 5.1(Protection against shock and energy hazards) |
- |
2000 |
|
20% discount to BIS |
| 5.2(Requirement of auxiliary circuits) |
- |
2000 |
|
20% discount to BIS |
| 5.3(Protective earthing and bonding) |
- |
2000 |
|
20% discount to BIS |
| 5.4(AC and DC power isolation) |
- |
1500 |
|
20% discount to BIS |
| 5.5(Over current and earth fault condition) |
- |
1500 |
|
20% discount to BIS |
| 5.6(Safety interlocks) |
- |
1250 |
|
20% discount to BIS |
| 5.7(CLEARANCES, CREEPAGE DISTANCES AND SOLID INSULATION) |
- |
1250 |
|
20% discount to BIS |
| 6.1(Wiring, connections and supply) |
- |
1250 |
|
20% discount to BIS |
| 6.2(Connection to power) |
- |
1250 |
|
20% discount to BIS |
| 6.3(Wiring terminals for external power conductors) |
- |
1250 |
|
20% discount to BIS |
| 7.1(Enclosure) |
- |
1250 |
|
20% discount to BIS |
| 7.2(STABILITY) |
- |
1250 |
|
20% discount to BIS |
| 7.3(MECHANICAL STRENGTH) |
- |
1250 |
|
20% discount to BIS |
| 7.4(Construction details) |
- |
1250 |
|
20% discount to BIS |
| 7.5(Resistance to fire) |
- |
1250 |
|
20% discount to BIS |
| 7.6(Battery location) |
- |
1250 |
|
20% discount to BIS |
| 7.7(Temperature rise) |
- |
1250 |
|
20% discount to BIS |
| 8.1(General procision for earth leakage) |
- |
1250 |
|
20% discount to BIS |
| 8.2(Electric Strength) |
- |
1250 |
|
20% discount to BIS |
| 8.3(Abnormal operating and fault conditions) |
- |
1250 |
|
20% discount to BIS |
| 9.0(Connection to telecommunication networks) |
- |
1250 |
|
20% discount to BIS |
|
23 Oct, 2028 |
- - |
| 41 |
CONFORMITY TESTING LABS PVT LTD (WH52)
| 8134626
| IS 16242 : Part 1 (2014) |
Uninterruptible power systems (UPS): Part 1 general and safety requirements for UPS |
- |
185625 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4.5(Components) |
- |
5000 |
|
10% Discount offered to BIS |
| 4.6(Power interface) |
- |
5000 |
|
10% Discount offered to BIS |
| 4.7(Marking & instructions) |
- |
5000 |
|
10% Discount offered to BIS |
| 5.1(Protection against shock and energy hazards) |
- |
5000 |
|
10% Discount offered to BIS |
| 5.2(Requirement of auxiliary circuits) |
- |
5000 |
|
10% Discount offered to BIS |
| 5.3(Protective earthing and bonding) |
- |
5000 |
|
10% Discount offered to BIS |
| 5.4(AC and DC power isolation) |
- |
5000 |
|
10% Discount offered to BIS |
| 5.5(Over current and earth fault condition) |
- |
5000 |
|
10% Discount offered to BIS |
| 5.6(Safety interlocks) |
- |
5000 |
|
10% Discount offered to BIS |
| 5.7(CLEARANCES, CREEPAGE DISTANCES AND SOLID INSULATION) |
- |
10000 |
|
10% Discount offered to BIS |
| 6.1(Wiring, connections and supply) |
- |
10000 |
|
10% Discount offered to BIS |
| 6.2(Connection to power) |
- |
5000 |
|
10% Discount offered to BIS |
| 6.3(Wiring terminals for external power conductors) |
- |
5000 |
|
10% Discount offered to BIS |
| 7.1(Enclosure) |
- |
5000 |
|
10% Discount offered to BIS |
| 7.2(STABILITY) |
- |
5000 |
|
10% Discount offered to BIS |
| 7.3(MECHANICAL STRENGTH) |
- |
10000 |
|
10% Discount offered to BIS |
| 7.4(Construction details) |
- |
10000 |
|
10% Discount offered to BIS |
| 7.5(Resistance to fire) |
- |
10000 |
|
10% Discount offered to BIS |
| 7.6(Battery location) |
- |
5000 |
|
10% Discount offered to BIS |
| 7.7(Temperature rise) |
- |
10000 |
|
10% Discount offered to BIS |
| 8.1(General procision for earth leakage) |
- |
5000 |
|
10% Discount offered to BIS |
| 8.2(Electric Strength) |
- |
5000 |
|
10% Discount offered to BIS |
| 8.3(Abnormal operating and fault conditions) |
- |
10000 |
|
10% Discount offered to BIS |
| 9.0(Connection to telecommunication networks) |
- |
5000 |
|
10% Discount offered to BIS |
|
19 Sep, 2028 |
- Excluding: Non-linear loads (Cl.3.3), Solid State Back-feed protection (Cl.5.1.4, Cl. I.5 of Annex I), Protection of Personnel Safety Interlocks (Cl. 5.6). |
| 42 |
DELHI TEST HOUSE (50) KUNDLI SONIPAT
| 9127026
| IS 16242 : Part 1 (2014) |
Uninterruptible power systems (UPS): Part 1 general and safety requirements for UPS |
- |
110000.00 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4.6(Power interface) |
- |
10000.00 |
|
Complete tests 55000.00/110000.00 for rating ≤10 KVA |
| 4.7(Marking & instructions) |
- |
4000.00 |
|
Complete tests 55000.00/110000.00 for rating ≤10 KVA |
| 5.1(Protection against shock and energy hazards) |
- |
6000.00 |
|
Complete tests 55000.00/110000.00 for rating ≤10 KVA |
| 5.2(Requirement of auxiliary circuits) |
- |
3000.00 |
|
Complete tests 55000.00/110000.00 for rating ≤10 KVA |
| 5.3(Protective earthing and bonding) |
- |
3000.00 |
|
Complete tests 55000.00/110000.00 for rating ≤10 KVA |
| 5.4(AC and DC power isolation) |
- |
4000.00 |
|
Complete tests 55000.00/110000.00 for rating ≤10 KVA |
| 5.5(Over current and earth fault condition) |
- |
4000.00 |
|
Complete tests 55000.00/110000.00 for rating ≤10 KVA |
| 5.6(Safety interlocks) |
- |
5000.00 |
|
Complete tests 55000.00/110000.00 for rating ≤10 KVA |
| 5.7(CLEARANCES, CREEPAGE DISTANCES AND SOLID INSULATION) |
- |
5000.00 |
|
Complete tests 55000.00/110000.00 for rating ≤10 KVA |
| 6.1(Wiring, connections and supply) |
- |
7000.00 |
|
Complete tests 55000.00/110000.00 for rating ≤10 KVA |
| 6.2(Connection to power) |
- |
7000.00 |
|
Complete tests 55000.00/110000.00 for rating ≤10 KVA |
| 6.3(Wiring terminals for external power conductors) |
- |
6000.00 |
|
Complete tests 55000.00/110000.00 for rating ≤10 KVA |
| 7.1(Enclosure) |
- |
3000.00 |
|
Complete tests 55000.00/110000.00 for rating ≤10 KVA |
| 7.2(STABILITY) |
- |
2000.00 |
|
Complete tests 55000.00/110000.00 for rating ≤10 KVA |
| 7.3(MECHANICAL STRENGTH) |
- |
2000.00 |
|
Complete tests 55000.00/110000.00 for rating ≤10 KVA |
| 7.4(Construction details) |
- |
3000.00 |
|
Complete tests 55000.00/110000.00 for rating ≤10 KVA |
| 7.5(Resistance to fire) |
- |
2000.00 |
|
Complete tests 55000.00/110000.00 for rating ≤10 KVA |
| 7.7(Temperature rise) |
- |
10000.00 |
|
Complete tests 55000.00/110000.00 for rating ≤10 KVA |
| 8.1(General procision for earth leakage) |
- |
6000.00 |
|
Complete tests 55000.00/110000.00 for rating ≤10 KVA |
| 8.2(Electric Strength) |
- |
6000.00 |
|
Complete tests 55000.00/110000.00 for rating ≤10 KVA |
| 8.3(Abnormal operating and fault conditions) |
- |
6000.00 |
|
Complete tests 55000.00/110000.00 for rating ≤10 KVA |
| 9.0(Connection to telecommunication networks) |
- |
4000.00 |
|
Complete tests 55000.00/110000.00 for rating ≤10 KVA |
| 4.5(Components) |
- |
1000 |
|
Complete tests 55000.00/110000.00 for rating ≤10 KVA |
| 7.6(Battery location) |
- |
1000 |
|
Complete tests 55000.00/110000.00 for rating ≤10 KVA |
|
23 Jun, 2028 |
- Excluding testing of Components (Cl.4.5) Cl. 7.6 and Annex-M – Ventilation of Battery Compartments Annex I.5 – Solid state backfeed protection Cl. 2.8.5/RD –Moving Parts Cl. 2.8.7.2/RD – Switches and Relays (Overload Test) Cl. 2.8.7.3/RD - Switches and Relays (Endurance Test) Cl. 2.10.5.4/RD and Annex- U – Semiconductor devices. Cl. 2.10.5.6/RD – Thin sheet Materials Cl. 2.10.5.8/RD –Non- Separable Thin sheet Materials Cl. 2.10.8/RD –Coated PCBs |
| 43 |
Aforeserve Labs Private Limited, Gurugram
| 9140626
| IS 16242 : Part 1 (2014) |
Uninterruptible power systems (UPS): Part 1 general and safety requirements for UPS |
upto 5kVA |
35000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4.6(Power interface) |
- |
1000 |
|
- |
| 4.7(Marking & instructions) |
- |
500 |
|
- |
| 5.1(Protection against shock and energy hazards) |
- |
500 |
|
- |
| 5.2(Requirement of auxiliary circuits) |
- |
900 |
|
- |
| 5.3(Protective earthing and bonding) |
- |
900 |
|
- |
| 5.4(AC and DC power isolation) |
- |
900 |
|
- |
| 5.5(Over current and earth fault condition) |
- |
900 |
|
- |
| 5.6(Safety interlocks) |
- |
900 |
|
- |
| 5.7(CLEARANCES, CREEPAGE DISTANCES AND SOLID INSULATION) |
- |
900 |
|
- |
| 6.1(Wiring, connections and supply) |
- |
900 |
|
- |
| 6.2(Connection to power) |
- |
900 |
|
- |
| 6.3(Wiring terminals for external power conductors) |
- |
900 |
|
- |
| 7.1(Enclosure) |
- |
900 |
|
- |
| 7.2(STABILITY) |
- |
900 |
|
- |
| 7.3(MECHANICAL STRENGTH) |
- |
900 |
|
- |
| 7.4(Construction details) |
- |
900 |
|
- |
| 7.5(Resistance to fire) |
- |
900 |
|
- |
| 7.6(Battery location) |
- |
900 |
|
- |
| 7.7(Temperature rise) |
- |
900 |
|
- |
| 8.1(General procision for earth leakage) |
- |
900 |
|
- |
| 8.2(Electric Strength) |
- |
900 |
|
- |
| 8.3(Abnormal operating and fault conditions) |
- |
900 |
|
- |
| 9.0(Connection to telecommunication networks) |
- |
900 |
|
- |
| 4.5/RD 1.5(Components) |
- |
900 |
|
- |
| 2.10.5.11(SMPS/Main transformer) |
- |
900 |
|
- |
| 2.10.6(PCB Material) |
- |
900 |
|
- |
| 3.2.5(Non-rewirable plug with PVC sheathed cable) |
- |
900 |
|
- |
| 3.2.4(Appliances inlets/connectors) |
- |
900 |
|
- |
| 2.10.5.4(Semiconductor devices) |
- |
900 |
|
- |
| 2.10.5.13(Winding wires) |
- |
900 |
|
- |
| 4.3.8(Batteries) |
- |
900 |
|
- |
| 2.10.5.6(Thin sheet material) |
- |
900 |
|
- |
| 5.6.1/ RD 2.8.7(Switches & Relays) |
- |
900 |
|
- |
| 6.1.1/ RD 3.1.4(Insulating Conductors) |
- |
900 |
|
- |
|
06 Jun, 2027 |
- Switches & Relays (Cl.2.8.2,2.8.5,2.8.7), Winding wires (Cl.2.10.5.3), Semi-conductor Devices (Cl.2.10.5.4), SMPS/Mains transformer (Cl. 2.10.5.11), PCB material (Cl.2.10.6), Wire in wound component (Cl.2.10.5.12), Wire with solvent based enamel in wound component (Cl.2.10.5.13), Additional insulation in wound component (Cl.2.10.5.14), Test for pollution degree 1 environment and insulating compound (Cl.2.10.10), Test for semiconductor devices and for cemented joints (Cl.2.10.11), enclosed and sealed parts (Cl.2.10.12), Internal wire (Cl.3.1.4), Batteries (Cl.4.3.8), Protection of personnel safety interlock (Cl.5.6), Ac power cords (Cl.6.2.1/RD-cl.3.2.6.1), Non rewirable plug with PVC sheathed cable (Cl.3.2.5) |
| 44 |
BLUESKY LAB LLP, GHAZIABAD
| 8170306
| IS 16242 : Part 1 (2014) |
Uninterruptible power systems (UPS): Part 1 general and safety requirements for UPS |
- |
75000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4.5(Components) |
- |
500 |
|
10% discount offered to BIS |
| 4.6(Power interface) |
- |
1500 |
|
10% discount offered to BIS |
| 4.7(Marking & instructions) |
- |
1000 |
|
10% discount offered to BIS |
| 5.1(Protection against shock and energy hazards) |
- |
1000 |
|
10% discount offered to BIS |
| 5.2(Requirement of auxiliary circuits) |
- |
2000 |
|
10% discount offered to BIS |
| 5.3(Protective earthing and bonding) |
- |
1500 |
|
10% discount offered to BIS |
| 5.4(AC and DC power isolation) |
- |
1500 |
|
10% discount offered to BIS |
| 5.5(Over current and earth fault condition) |
- |
2000 |
|
10% discount offered to BIS |
| 5.6(Safety interlocks) |
- |
2500 |
|
10% discount offered to BIS |
| 5.7(CLEARANCES, CREEPAGE DISTANCES AND SOLID INSULATION) |
- |
5000 |
|
10% discount offered to BIS |
| 6.1(Wiring, connections and supply) |
- |
500 |
|
10% discount offered to BIS |
| 6.2(Connection to power) |
- |
2000 |
|
10% discount offered to BIS |
| 6.3(Wiring terminals for external power conductors) |
- |
1500 |
|
10% discount offered to BIS |
| 7.1(Enclosure) |
- |
3000 |
|
10% discount offered to BIS |
| 7.2(STABILITY) |
- |
3000 |
|
10% discount offered to BIS |
| 7.3(MECHANICAL STRENGTH) |
- |
15000 |
|
10% discount offered to BIS |
| 7.4(Construction details) |
- |
3000 |
|
10% discount offered to BIS |
| 7.6(Battery location) |
- |
2000 |
|
10% discount offered to BIS |
| 7.7(Temperature rise) |
- |
8000 |
|
10% discount offered to BIS |
| 8.1(General procision for earth leakage) |
- |
1500 |
|
10% discount offered to BIS |
| 8.2(Electric Strength) |
- |
5000 |
|
10% discount offered to BIS |
| 8.3(Abnormal operating and fault conditions) |
- |
8000 |
|
10% discount offered to BIS |
| 9.0(Connection to telecommunication networks) |
- |
6000 |
|
10% discount offered to BIS |
| 7.5(Resistance to fire) |
- |
5000 |
|
10% discount offered to BIS |
| 4.5/RD 1.5(Components) |
- |
500 |
|
10% discount offered to BIS |
|
22 May, 2028 |
- Exclusions: Restricted upto 10Kva Single Phase only. Excluding: Components (Cl.4.5/ RD, CI.
1.5), Winding Wires (Cl. 2.10.5.3), Semiconductor Devices (Cl. 2.10.5.4),
SMPS/Main transformer (cl.2.10.5.11); PCB Material (cl.2.10.6); SMPS/ Mains
Transformer (Cl. 2.10.5.11), Wire in wound components (Cl. 2.10.5.12), Wire with
solvent based enamel in wound components (Cl. 2.10.5.13), Additional
insulation in wound components (Cl. 2.10.5.14), Tests for pollution degree 1
environment & for insulating compound (Cl. 2.10.10), Tests for semiconductor
devices & for cemented joints (Cl. 2.10.11), Enclosed & sealed parts (Cl. 2.10.12),
Internal Wire (Cl. 3.1.4), Batteries (Cl.4.3.8), Non-rewirable Plug with PVC
Sheathed Cable (Cl. 3.2.5), Construction of printed circuit boards (Cl.5.7/RD/2.10.6),
Wiring, connection and supply (Cl.6.1.1/RD 3.1.4), Batteries (Cl. 4.3.8), Performance Tests: Simulators (ESD/EFT/Voltage Dip Interruption/PFMF), Gas Concentration, Ventilation of Battery Compartments (Cl.7.4.3, Cl.7.6.7 & Annex- M), Non-rewirable plug with PVC sheathed cable (Cl.3.2.5), Performance tests:simulators immunity to Low frequency signals (Annex L.5.2 (IEC 32040-2,CI.7.3)). Switches & Relays (cl.5.6.1 / RD cl.2.8.7); Insulating Conductors (cl.6.1.1/RD
cl.3.1.4) |
| 45 |
Conformity Testing Labs Pvt. Ltd. Unit 2 (A33)
| 8139626
| IS 16242 : Part 1 (2014) |
Uninterruptible power systems (UPS): Part 1 general and safety requirements for UPS |
- |
200000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4.5(Components) |
- |
5000 |
|
10% discount for BIS |
| 4.6(Power interface) |
- |
5000 |
|
10% discount for BIS |
| 4.7(Marking & instructions) |
- |
5000 |
|
10% discount for BIS |
| 5.1(Protection against shock and energy hazards) |
- |
5000 |
|
10% discount for BIS |
| 5.2(Requirement of auxiliary circuits) |
- |
5000 |
|
10% discount for BIS |
| 5.3(Protective earthing and bonding) |
- |
5000 |
|
10% discount for BIS |
| 5.4(AC and DC power isolation) |
- |
5000 |
|
10% discount for BIS |
| 5.5(Over current and earth fault condition) |
- |
5000 |
|
10% discount for BIS |
| 5.6(Safety interlocks) |
- |
5000 |
|
10% discount for BIS |
| 5.7(CLEARANCES, CREEPAGE DISTANCES AND SOLID INSULATION) |
- |
10000 |
|
10% discount for BIS |
| 6.1(Wiring, connections and supply) |
- |
10000 |
|
10% discount for BIS |
| 6.2(Connection to power) |
- |
5000 |
|
10% discount for BIS |
| 6.3(Wiring terminals for external power conductors) |
- |
5000 |
|
10% discount for BIS |
| 7.1(Enclosure) |
- |
5000 |
|
10% discount for BIS |
| 7.2(STABILITY) |
- |
5000 |
|
10% discount for BIS |
| 7.3(MECHANICAL STRENGTH) |
- |
10000 |
|
10% discount for BIS |
| 7.4(Construction details) |
- |
10000 |
|
10% discount for BIS |
| 7.5(Resistance to fire) |
- |
10000 |
|
10% discount for BIS |
| 7.6(Battery location) |
- |
5000 |
|
10% discount for BIS |
| 7.7(Temperature rise) |
- |
10000 |
|
10% discount for BIS |
| 8.1(General procision for earth leakage) |
- |
5000 |
|
10% discount for BIS |
| 8.2(Electric Strength) |
- |
5000 |
|
10% discount for BIS |
| 8.3(Abnormal operating and fault conditions) |
- |
10000 |
|
10% discount for BIS |
| 9.0(Connection to telecommunication networks) |
- |
5000 |
|
10% discount for BIS |
|
05 Apr, 2027 |
- Solid State Back Feed Protection (I.5 of Annex I), Component (Cl.4.5 (1.5/RD)), Safety Interlocks (Cl.5.6.1(2.8/RD)) |
| 46 |
Bharat Test House Pvt Ltd 1474 Sonipat Haryana
| 9135626
| IS 16242 : Part 1 (2014) |
Uninterruptible power systems (UPS): Part 1 general and safety requirements for UPS |
- |
160000 View breakup
Rs.80000/- for ≤ 5KVA
Rs.115000/- for ≥ 5KVA
(5% discount for BIS). Rs.1,85,000/- for > 10 KVA (for 3 phase)
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4.5(Components) |
- |
0 |
|
- |
| 4.6(Power interface) |
- |
5000 |
|
5% discount for BIS |
| 4.7(Marking & instructions) |
- |
2000 |
|
5% discount for BIS |
| 5.1(Protection against shock and energy hazards) |
- |
4000 |
|
5% discount for BIS |
| 5.2(Requirement of auxiliary circuits) |
- |
4000 |
|
5% discount for BIS |
| 5.3(Protective earthing and bonding) |
- |
7000 |
|
5% discount for BIS |
| 5.4(AC and DC power isolation) |
- |
3000 |
|
5% discount for BIS |
| 5.5(Over current and earth fault condition) |
- |
5000 |
|
5% discount for BIS |
| 5.6(Safety interlocks) |
- |
6000 |
|
5% discount for BIS |
| 5.7(CLEARANCES, CREEPAGE DISTANCES AND SOLID INSULATION) |
- |
6000 |
|
5% discount for BIS |
| 6.1(Wiring, connections and supply) |
- |
12000 |
|
5% discount for BIS |
| 6.2(Connection to power) |
- |
13000 |
|
5% discount for BIS |
| 6.3(Wiring terminals for external power conductors) |
- |
10000 |
|
5% discount for BIS |
| 7.1(Enclosure) |
- |
1000 |
|
5% discount for BIS |
| 7.2(STABILITY) |
- |
2000 |
|
5% discount for BIS |
| 7.3(MECHANICAL STRENGTH) |
- |
2000 |
|
5% discount for BIS |
| 7.4(Construction details) |
- |
5000 |
|
5% discount for BIS |
| 7.5(Resistance to fire) |
- |
7000 |
|
5% discount for BIS |
| 7.6(Battery location) |
- |
3000 |
|
5% discount for BIS |
| 7.7(Temperature rise) |
- |
5000 |
|
5% discount for BIS |
| 8.1(General procision for earth leakage) |
- |
7000 |
|
5% discount for BIS |
| 8.2(Electric Strength) |
- |
8000 |
|
5% discount for BIS |
| 8.3(Abnormal operating and fault conditions) |
- |
15000 |
|
5% discount for BIS |
| 9.0(Connection to telecommunication networks) |
- |
28000 |
|
5% discount for BIS |
|
19 Mar, 2026 |
- Single Phase and 3 phase.
Except :
Cl. 4.5 : Components
Cl. 1.5 radio frequency electromagnetic field, amplitude modulated, immunity to power frequency magnetic field, immunity to low frequency signals, Cl. 5.6.1 Operator protection,
Cl.7.6.7 & Annex M_Ventilation,Cl. 2.10.5.12 Insulated winding wires |
| 47 |
Matrix Test Labs
| 8138626
| IS 16242 : Part 1 (2014) |
Uninterruptible power systems (UPS): Part 1 general and safety requirements for UPS |
- |
125000 View breakup
Rs.1,25,000/- UPS/ Invertors Up to 5
kVA)
[10% discount to BIS]
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4.6(Power interface) |
- |
15000 |
|
10% discount to BIS |
| 4.7(Marking & instructions) |
- |
10000 |
|
10% discount to BIS |
| 5.1(Protection against shock and energy hazards) |
- |
5000 |
|
10% discount to BIS |
| 5.2(Requirement of auxiliary circuits) |
- |
5000 |
|
10% discount to BIS |
| 5.3(Protective earthing and bonding) |
- |
5000 |
|
10% discount to BIS |
| 5.5(Over current and earth fault condition) |
- |
5000 |
|
10% discount to BIS |
| 5.6(Safety interlocks) |
- |
5000 |
|
10% discount to BIS |
| 5.7(CLEARANCES, CREEPAGE DISTANCES AND SOLID INSULATION) |
- |
5000 |
|
10% discount to BIS |
| 6.1(Wiring, connections and supply) |
- |
5000 |
|
10% discount to BIS |
| 6.2(Connection to power) |
- |
5000 |
|
10% discount to BIS |
| 6.3(Wiring terminals for external power conductors) |
- |
5000 |
|
10% discount to BIS |
| 7.2(STABILITY) |
- |
5000 |
|
10% discount to BIS |
| 7.3(MECHANICAL STRENGTH) |
- |
5000 |
|
10% discount to BIS |
| 7.4(Construction details) |
- |
5000 |
|
10% discount to BIS |
| 7.5(Resistance to fire) |
- |
10000 |
|
10% discount to BIS |
| 7.6(Battery location) |
- |
5000 |
|
10% discount to BIS |
| 7.7(Temperature rise) |
- |
15000 |
|
10% discount to BIS |
| 8.1(General procision for earth leakage) |
- |
5000 |
|
10% discount to BIS |
| 8.2(Electric Strength) |
- |
5000 |
|
10% discount to BIS |
| 8.3(Abnormal operating and fault conditions) |
- |
10000 |
|
10% discount to BIS |
| 9.0(Connection to telecommunication networks) |
- |
10000 |
|
10% discount to BIS |
| 4.5(Components) |
- |
15000 |
|
10% discount to BIS |
| 5.4(AC and DC power isolation) |
- |
0 |
|
- |
| 7.1(Enclosure) |
- |
5000 |
|
10% discount to BIS |
|
31 Dec, 2026 |
- Following Additional
Test Facility included
w.e.f. 18.09.2018:
Protection against
ingress of foreign
objects (IPX7 & IPX8
only) (Cl.1.2 & AnnexH).
Excluding: Non-linear
loads (Cl.3.3),
Components (Cl.4.5 /
RD 1.5), Protection of
Personnel-Safety
Interlocks (Cl. 5.6/ RD
Cl.2.8.5, Cl.2.8.7.1 to
Cl.2.8.7.3),
Semiconductor devices
(Cl.2.10.5.4 of RD) and
Insulation in wound
components
(Cl.2.10.5.11 of RD). |
| 48 |
Ace Test Labs & Metrology Pvt. Ltd., Sonipat
| 9162826
| IS 16242 : Part 1 (2014) |
Uninterruptible power systems (UPS): Part 1 general and safety requirements for UPS |
- |
108000 View breakup
Rs.108000/-
(10% discount for BIS)
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4.6(Power interface) |
- |
3000 |
|
10% Discount for BIS |
| 4.7(Marking & instructions) |
- |
2000 |
|
10% Discount for BIS |
| 5.1(Protection against shock and energy hazards) |
- |
3000 |
|
10% Discount for BIS |
| 5.2(Requirement of auxiliary circuits) |
- |
5000 |
|
10% Discount for BIS |
| 5.3(Protective earthing and bonding) |
- |
5000 |
|
10% Discount for BIS |
| 5.5(Over current and earth fault condition) |
- |
10000 |
|
10% Discount for BIS |
| 5.7(CLEARANCES, CREEPAGE DISTANCES AND SOLID INSULATION) |
- |
10000 |
|
10% Discount for BIS |
| 6.1(Wiring, connections and supply) |
- |
5000 |
|
10% Discount for BIS |
| 6.3(Wiring terminals for external power conductors) |
- |
5000 |
|
10% Discount for BIS |
| 7.2(STABILITY) |
- |
5000 |
|
10% Discount for BIS |
| 7.3(MECHANICAL STRENGTH) |
- |
4000 |
|
4000 (each )10% Discount for BIS |
| 7.4(Construction details) |
- |
5000 |
|
10% Discount for BIS |
| 7.5(Resistance to fire) |
- |
8000 |
|
8000 (Each)10% Discount for BIS |
| 7.7(Temperature rise) |
- |
10000 |
|
Rs 10000/- for 10 points, 10% Discount for BIS |
| 8.1(General procision for earth leakage) |
- |
8000 |
|
10% Discount for BIS |
| 8.2(Electric Strength) |
- |
7000 |
|
10% Discount for BIS |
| 8.3(Abnormal operating and fault conditions) |
- |
8000 |
|
10% Discount for BIS |
| 9.0(Connection to telecommunication networks) |
- |
5000 |
|
10% Discount for BIS |
|
14 Nov, 2027 |
- Only for IP(0-4)(5-6)
For UPS/Inverter up to 5KVA), UPS < =10 KVA
Excluding:
Cl. 4.5/1.5 of RD Components -
Cl. 5.6/2.8 of RD Safety Interlocks
Cl. 2.10.5.4 & Annex U of RD Semiconductor Devices
Cl.2.10.6 PCB material,
Cl. 2.10.5.11 Insulation in wound components,
CL.7.6 & Annex-M
Ventilation of battery Compartment,
Annex-L.5 Non linear Loads,
Annex-I.5 Solid state backfeed protection
Annex-H /Table
Protection against Ingress of foreign objects |
| 49 |
URS PRODUCTS AND TESTING PVT LTD (F3), NOIDA
| 8136826
| IS 16242 : Part 1 (2014) |
Uninterruptible power systems (UPS): Part 1 general and safety requirements for UPS |
- |
75000 View breakup
Rs.75,000/- [15% Discount to BIS]
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4.5(Components) |
- |
500 |
|
Rs.45,000/- for UPS/Invertersof rating up to 5 kVA
15% discount to BIS |
| 4.6(Power interface) |
- |
10000 |
|
Rs.45,000/- for UPS/Invertersof rating up to 5 kVA
15% discount to BIS |
| 4.7(Marking & instructions) |
- |
1000 |
|
Rs.45,000/- for UPS/Invertersof rating up to 5 kVA
15% discount to BIS |
| 5.1(Protection against shock and energy hazards) |
- |
7000 |
|
Rs.45,000/- for UPS/Invertersof rating up to 5 kVA
15% discount to BIS |
| 5.2(Requirement of auxiliary circuits) |
- |
1000 |
|
Rs.45,000/- for UPS/Invertersof rating up to 5 kVA
15% discount to BIS |
| 5.3(Protective earthing and bonding) |
- |
8000 |
|
Rs.45,000/- for UPS/Invertersof rating up to 5 kVA
15% discount to BIS |
| 5.4(AC and DC power isolation) |
- |
7500 |
|
Rs.45,000/- for UPS/Invertersof rating up to 5 kVA
15% discount to BIS |
| 5.5(Over current and earth fault condition) |
- |
3000 |
|
Rs.45,000/- for UPS/Invertersof rating up to 5 kVA
15% discount to BIS |
| 5.6(Safety interlocks) |
- |
1000 |
|
Rs.45,000/- for UPS/Invertersof rating up to 5 kVA
15% discount to BIS |
| 5.7(CLEARANCES, CREEPAGE DISTANCES AND SOLID INSULATION) |
- |
4000 |
|
Rs.45,000/- for UPS/Invertersof rating up to 5 kVA
15% discount to BIS |
| 6.1(Wiring, connections and supply) |
- |
2000 |
|
Rs.45,000/- for UPS/Invertersof rating up to 5 kVA
15% discount to BIS |
| 6.2(Connection to power) |
- |
1500 |
|
Rs.45,000/- for UPS/Invertersof rating up to 5 kVA
15% discount to BIS |
| 6.3(Wiring terminals for external power conductors) |
- |
2000 |
|
Rs.45,000/- for UPS/Invertersof rating up to 5 kVA
15% discount to BIS |
| 7.1(Enclosure) |
- |
2000 |
|
Rs.45,000/- for UPS/Inverters of rating up to 5 kVA
15% discount to BIS |
| 7.2(STABILITY) |
- |
2000 |
|
Rs.45,000/- for UPS/Inverters of rating up to 5 kVA
15% discount to BIS |
| 7.3(MECHANICAL STRENGTH) |
- |
4000 |
|
Rs.45,000/- for UPS/Inverters of rating up to 5 kVA
15% discount to BIS |
| 7.4(Construction details) |
- |
500 |
|
Rs.45,000/- for UPS/Inverters of rating up to 5 kVA
15% discount to BIS |
| 7.5(Resistance to fire) |
- |
2000 |
|
Rs.45,000/- for UPS/Inverters of rating up to 5 kVA
15% discount to BIS |
| 7.6(Battery location) |
- |
1000 |
|
Rs.45,000/- for UPS/Inverters of rating up to 5 kVA
15% discount to BIS |
| 7.7(Temperature rise) |
- |
3000 |
|
Rs.45,000/- for UPS/Inverters of rating up to 5 kVA
15% discount to BIS |
| 8.1(General procision for earth leakage) |
- |
3000 |
|
Rs.45,000/- for UPS/Inverters of rating up to 5 kVA
15% discount to BIS |
| 8.2(Electric Strength) |
- |
4000 |
|
Rs.45,000/- for UPS/Inverters of rating up to 5 kVA
15% discount to BIS |
| 8.3(Abnormal operating and fault conditions) |
- |
3000 |
|
Rs.45,000/- for UPS/Inverters of rating up to 5 kVA
15% discount to BIS |
| 9.0(Connection to telecommunication networks) |
- |
2000 |
|
Rs.45,000/- for UPS/Inverters of rating up to 5 kVA
15% discount to BIS |
|
31 Dec, 2026 |
- Excluding: Capacitor Bridging Insulation (Cl.4.5 / RD 1.5.6), Resistor Bridging Insulation (Cl.4.5 / RD 1.5.7), Surge Suppressor (Cl.4.5 / RD 1.5.7), Ventilation of Battery Compartment (Cl. Annex-M). Non-linear loads (Cl.3.3.3, Annex-L.5).
Additional Products/
Test Facility included
w.e.f. 18.07.2018.
For rating up to 300V,
1Φ, AC |