| 61 |
BIS, Patna Branch Laboratory (PBL)
| None
| IS 1786 (2008) |
High strength deformed steel bars and wires for concretere inforcement - Specification (Fourth Revision) |
- |
25780 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl 5 (Deformations and Surface Characteristics) |
- |
|
|
|
| Clause - 4.2 & 4.2.1 (Fe- 415, Fe- 415D, Fe-500, Fe-500D, Fe-550, Fe-550D, Fe-600 CARBON +EQUIVELENT ) |
- |
|
|
|
| Cl.9.4 & Cl. 9.4.1 (Rebend test) |
- |
|
|
|
| Cl. 9.3, Table 4 (Bend Test ) |
- |
|
|
|
| Cl. 8.1 Table 3 (Elongation, percentage) |
- |
|
|
|
| Cl. 8.1 Table 3 (TS/YS ratio) |
- |
|
|
|
| Cl. 8.1 Table 3 (Tensile Strength (TS)) |
- |
|
|
|
| Cl. 8.1 Table 3 (Yield Stress (YS)) |
- |
|
|
|
| Cl. 7.2 Table -2 (Nominal Mass) |
- |
|
|
|
| Cl. 6.1 (Nominal Size) |
- |
|
|
|
| Cl. 5 (Cl. 5 - Mean projected area of transverse ribs (1/3 of Ar)) |
- |
|
|
|
| Cl. 5 (Cl.5 Mean area of ribs/unit length (Ar), ) |
- |
|
|
|
| Clause - 4.2 & 4.2.1 (Fe- 415, Fe- 415D, Fe-500, Fe-500D, Fe-550, Fe-550D, Fe-600 SULPHUR+PHOSPHUR) |
- |
|
|
|
| Clause - 4.2 & 4.2.1 (Fe- 415, Fe- 415D, Fe-500, Fe-500D, Fe-550, Fe-550D, Fe-600 MANGANESE) |
- |
|
|
|
| Clause - 4.2 & 4.2.1 (Fe- 415, Fe- 415D, Fe-500, Fe-500D, Fe-550, Fe-550D, Fe-600 NITROGEN) |
- |
|
|
|
| Clause - 4.2 & 4.2.1 (Fe- 415, Fe- 415D, Fe-500, Fe-500D, Fe-550, Fe-550D, Fe-600 PHOSPHURS) |
- |
|
|
|
| Clause - 4.2 & 4.2.1 (Fe- 415, Fe- 415D, Fe-500, Fe-500D, Fe-550, Fe-550D, Fe-600 SULPHUR) |
- |
|
|
|
| Clause - 4.2 & 4.2.1 (Fe- 415, Fe- 415D, Fe-500, Fe-500D, Fe-550, Fe-550D, Fe-600 CARBON ) |
- |
|
|
|
| Cl. 5.3 (a) (The ribs contributing the projected area - Longitudinal Ribs) |
- |
|
|
|
| Cl. 5.3 (b) (The ribs contributing the projected area - Transverse Ribs) |
- |
|
|
|
|
- |
- All test facilities are available as per the IS except-
i. Bond/Pull Out Test (Clause 5.7)
ii. Total Elongation at Maximum Force (Clause 8.1 and Table 3)
iii. Tensile Test of Sizes > 16mm (Clause 8.1 and Table 3)
iv. Tests for microalloying elements (Ti, Nb, B, V), Cr, Mo, Cu, Ni and Al (Clause 4.2) |
| 62 |
BIS, Western Regional Laboratory (WRL)
| None
| IS 1786 (2008) |
High strength deformed steel bars and wires for concretere inforcement - Specification (Fourth Revision) |
- |
25780 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl. 6.1 (Nominal Size) |
- |
|
|
|
| Cl 7.2 (Weight) |
- |
|
|
|
| Cl. 8.1 Table 3 (Elongation, percentage) |
- |
|
|
|
| Cl. 8.1 Table 3 (TS/YS ratio) |
- |
|
|
|
| Cl. 8.1 Table 3 (Tensile Strength (TS)) |
- |
|
|
|
| Cl. 5 (Cl.5 Mean area of ribs/unit length (Ar), ) |
- |
|
|
|
| Cl. 5 (Cl. 5 - Mean projected area of transverse ribs (1/3 of Ar)) |
- |
|
|
|
| Cl. 9.3, Table 4 (Bend Test ) |
- |
|
|
|
| Cl.9.4 & Cl. 9.4.1 (Rebend test) |
- |
|
|
|
| 4.1 (Silicon %) |
- |
|
|
|
| 4.1 (Sulphur %) |
- |
|
|
|
| 4.1 (Phosphorus %) |
- |
|
|
|
| 4.1 (Manganese %) |
- |
|
|
|
| 4.1 (Carbon %) |
- |
|
|
|
| Cl. 8.1 Table 3 (Yield Stress (YS)) |
- |
|
|
|
| 4.1 (Sulphur and phosphorous) |
- |
|
|
|
|
- |
- Test facilities are not available for the following:
(1) Total elongation at maximum force,
(2) Pull out test (Type test)
(3) Sizes above 25 mm,
(4) Micro-alloy/low alloys, Nb, V, B and Ti, Cr, Cu, Ni, Mo, Nirogen and nitrogen binding elements, like Nb, V, Ti, Al |
| 63 |
BIS, Guwahati Branch Laboratory (GBL)
| None
| IS 1786 (2008) |
High strength deformed steel bars and wires for concretere inforcement - Specification (Fourth Revision) |
Up to nominal dia of 25 mm |
25780 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl. 8.1 Table 3 (Yield Stress (YS)) |
- |
|
|
|
| Cl. 8.1 Table 3 (Tensile Strength (TS)) |
- |
|
|
|
| Cl. 8.1 Table 3 (TS/YS ratio) |
- |
|
|
|
| Cl. 8.1 Table 3 (Elongation, percentage) |
- |
|
|
|
| Cl. 5 (Cl. 5 - Mean projected area of transverse ribs (1/3 of Ar)) |
- |
|
|
|
| Cl.9.4 & Cl. 9.4.1 (Rebend test) |
- |
|
|
|
| Cl. 7.2 Table -2 (Nominal Mass) |
- |
|
|
|
| Cl. 6.1 (Nominal Size) |
- |
|
|
|
| Cl. 5 (Cl.5 Mean area of ribs/unit length (Ar), ) |
- |
|
|
|
| Cl. 9.3, Table 4 (Bend Test ) |
- |
|
|
|
| Cl. 8.1 Table 3 (Total Elongation at Maximum Force) |
- |
|
|
|
| Clause - 4.2 & 4.2.1 (Fe- 415, Fe- 415D, Fe-500, Fe-500D, Fe-550, Fe-550D, Fe-600 CARBON ) |
- |
|
|
|
| Clause - 4.2 & 4.2.1 (Fe- 415, Fe- 415D, Fe-500, Fe-500D, Fe-550, Fe-550D, Fe-600 SULPHUR) |
- |
|
|
|
| Clause - 4.2 & 4.2.1 (Fe- 415, Fe- 415D, Fe-500, Fe-500D, Fe-550, Fe-550D, Fe-600 PHOSPHURS) |
- |
|
|
|
| Cl.4.2 of IS 1786 (Grade:- Fe 415,Fe 415D,Fe 415S,Fe 500,Fe 500D,Fe 500S,Fe 550,Fe 550D,Fe600,Fe 650,Fe 700) (Sulphur & Phosphorous) |
- |
|
|
|
| Cl.4.2 of IS 1786 (Vanadium- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
|
|
|
| Cl.4.2 of IS 1786 (Molybdenum- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
|
|
|
| Cl.4.2 of IS 1786 (Chromium- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
|
|
|
| Cl.4.2 of IS 1786 (Nickel- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
|
|
|
| Cl.4.2 of IS 1786 (Copper- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
|
|
|
| Cl.4.2 of IS 1786 (Nitrogen- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
|
|
|
| Cl.4.2 of IS 1786 (Manganese- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
|
|
|
| Cl.4.2 of IS 1786 (Grade:- Fe 415D,Fe 415S, Fe 500D,Fe 500S,Fe 550D) (Carbon Equivalent) |
- |
|
|
|
| 4.1 (Carbon %) |
- |
|
|
|
| 4.1 (Sulphur %) |
- |
|
|
|
| 4.1 (Phosphorus %) |
- |
|
|
|
| 4.1 (Sulphur and phosphorous) |
- |
|
|
|
|
- |
- Qty. required Mech -3 Pcs of 1 meter,
Chem- 5 pcs* 50 mm
i) Tensile Strength, Yield Stress, Elongation percentage Test facility available up to diameter 20 mm.
ii) Except Pull-out test." |