Search by IS Number
Reset
11387 Results
S.No. Lab Name Osl Code Indian Standard No. Product Grade / Type / Size / Designation etc. Testing Charges (Excl. Of Taxes) Validity Date Remark
11371 BIS Patna Branch Laboratory (PBL) None IS 1489 (Part 1) (2015) Portland pozzolana cement - Specification: Part 1 fly Ash Based - - View breakup
-
- -
All test facilities are available as per the IS except Transverse Strength Test (Clause 7 and Table-2) which is an optional test
11372 BIS Patna Branch Laboratory (PBL) None IS 1659 (2004) Block boards - Specification (Fourth Revision) - - View breakup
-
- -
All test facilities are available as per the IS
11373 BIS Patna Branch Laboratory (PBL) None IS 303 (1989) Plywood for General Purposes - - Rs 4000/- /BWR Grade, Rs.4900/- for MR Grade View breakup
-
- -
All test facilities are available as per the IS
11374 BIS Patna Branch Laboratory (PBL) None IS 269 (2015) Ordinary portland cement - Specification (Sixth Revision) - - View breakup
-
- -
All test facilities are available as per the IS except Transverse Strength Test (Clause 7 and Table-3) which is an optional test
11375 BIS Patna Branch Laboratory (PBL) None IS 455 (2015) Portland slag cement - Specification - - View breakup
-
- -
All test facilities are available as per the IS except Transverse Strength Test (Clause 7 and Table 2) which is an optional test
11376 BIS Patna Branch Laboratory (PBL) None IS 12818 (2010) Unplasticized polyvinyl chloride (Pvc - U) screen and casing pipes for bore/tubewells - Specification (Second Revision) - - View breakup
-
- -
All test facilities available except Effect on Water (Clause 9.7)
11377 BIS, Eastern Regional Laboratory (ERL) None IS 455 (2015) Portland slag cement - Specification - - View breakup
-
- -
Mech-Facility not available for transverse strength test( optional); Chem-Declaration for chloride regarding end use of cement required as per Table 1, Confirmation for testing Alkali Content required.
11378 BIS, Eastern Regional Laboratory (ERL) None IS 4984 (2016) Polyethylene pipes for water supply - Specification (Fifth Revision) All varieties - View breakup
-
- -
Mech- Facility not available for- Hydraulic test, Slow Crack Growth Rate and Internal Pressure Creep Rupture test. Fused pipes required to be provided for T/S of butt fusion joints. Chem- Facility available
11379 BIS, Eastern Regional Laboratory (ERL) None IS 1489 (Part 1) (2015) Portland pozzolana cement - Specification: Part 1 fly Ash Based - - View breakup
-
- -
Mech- Facility not available for transverse strength test( optional); Chem-Declaration for chloride regarding end use of cement (as per Table 1) and declaration of fly ash content & Confirmation for testing Alkali Content required.
11380 BIS, Eastern Regional Laboratory (ERL) None IS 694 (2010) Polyvinyl chloride insulated unsheathed and sheathed cables/cords with rigid and flexible conductor for rated voltages up to and including 450/750 v (Fourth Revision) Complete for Category 01- up to & including 400 sq mm - View breakup
-
- -
Chem- Facility available for Cu purity only,Gr to be declared. Elect- Cat -01, 02 (Facility not available for- Loss of mass above 1.2 mm, Tensile & Elongation above 2.0 mm thickness.) Cat- FR, FR-LSH-( Facility not available for- oxygen index, temp. index test, Smoke Density Tests). Chem- Facility available for Cu purity only,Grade/class to be declared
11381 BIS, Central Laboratory (CL) None IS 13334 : Part 1 (2014) Skimmed milk powder - Specification: Part 1 standard grade (Second Revision) - - View breakup
-
- -
500 gm x 3
11382 BIS, Western Regional Laboratory (WRL) None IS 1786 (2008) High strength deformed steel bars and wires for concretere inforcement - Specification (Fourth Revision) - - View breakup
Rs 16740/- Excluding Pull Out Test and micro-alloying elements
- -
Test facilities are not available for the following: (1) Total elongation at maximum force, (2) Pull out test (Type test) (3) Sizes above 25 mm, (4) Micro-alloy/low alloys, Nb, V, B and Ti, Cr, Cu, Ni, Mo, Nirogen and nitrogen binding elements, like Nb, V, Ti, Al
11383 BIS, Bengaluru Branch Laboratory (BNBL) None IS 2347 (2017) Domestic pressure cooker - Specification (Sixth Revision) - - View breakup
-
- -
Except Material Testing
11384 BIS, Bengaluru Branch Laboratory (BNBL) None IS 1489 (Part 1) (2015) Portland pozzolana cement - Specification: Part 1 fly Ash Based - - View breakup
-
- -
Expect Transverse Strength
11385 BIS, Bengaluru Branch Laboratory (BNBL) None IS 269 (2015) Ordinary portland cement - Specification (Sixth Revision) 33 GR 43GR 53 GR - View breakup
-
- -
Expect Transverse Strength
11386 BIS, Central Laboratory (CL) None IS 303 (2024) Plywood for General Purposes — Specification (Fourth Revision) - Rs 4000/- /BWR Grade, Rs.4900/- for MR Grade View breakup
-
- -
Facility not available: Static bending strength above 15 mm thickness. ; Excluding- Steady State Formaldehyde Emission Test (Cl. 11.7)
11387 BIS, Guwahati Branch Laboratory (GBL) None IS 1786 (2008) High strength deformed steel bars and wires for concretere inforcement - Specification (Fourth Revision) Up to nominal dia of 25 mm - View breakup
-
- -
1. T.F. not available for Pull out test. 2. Tensile Strength, Yield Stress, Elongation T.F. available up to nominal dia of 25 mm.

Designed, Developed and Maintained by:

Arohatech IT Services (P) Ltd.

Contact for any query/support: supportlims@bis.gov.in