S.No. Lab Name Osl Code Indian Standard No. Product Grade / Type / Size / Designation etc. Testing Charges (Excl. Of Taxes) Validity Date Remark
11581 BIS, Central Laboratory (CL) None IS 1824 (1978) Specification for insecticidal space spray - Rs 4200/- View breakup
-
- -
Excluding Table 1 Cl. 2.2 Content;
11582 BIS, Western Regional Laboratory (WRL) None IS 9968 : Part 1 (1988) Specification for elastomer insulatedcables: Part 1 for working voltages up to and including 1100 volts (First Revision) - Rs.12000/ View breakup
-
- -
The following test facilities for clauses are not available: 1. Tear resistance test. 2. Water absorption (Electrical) Test for IE2 type elastomeric insulation
11583 BIS, Northern Regional Laboratory (NRL) None IS 2721 (2003) Galvanized steel chain link fence fabric - Specification (Second Revision) - - View breakup
Rs.5950/- (for wire below 5 mm Dia), Rs.6910/- (for wires above 5 mm Dia) and Material testing charges as per relevant referred Iss
- -
Test facility is complete
11584 BIS, Western Regional Laboratory (WRL) None IS 9857 (1990) Welding cables - Specification (First Revision) - Rs 11400/- View breakup
-
- -
Complete test facility is available
11585 BIS, Northern Regional Laboratory (NRL) None IS 4223 (1975) Steel Wire For Umbrella Ribs - - View breakup
-
- -
Test facility is complete
11586 BIS, Central Laboratory (CL) None IS 12299 (1998) Dairy whitener - Specification (First Revision) - Rs. 18300/- View breakup
-
- -
500 gm x 3
11587 BIS, Western Regional Laboratory (WRL) None IS 9537 : Part 3 (1983) Specification for conduits for electrical installations: Part 3 rigid plain conduits of insulating meterials - Rs. 3300.00/, Rs. 2850.00/ View breakup
-
- -
Complete test facility is available
11588 BIS, Northern Regional Laboratory (NRL) None IS 2028 (2004) Open jaw wrenches (Spanners) - Specification (Fijih Revision) - Rs.3700/- View breakup
-
- -
Excluding Torque test, Micro alloying elements
11589 BIS, Central Laboratory (CL) None IS 1488 (1989) Pesticides - 2, 4 - D sodium salt, technical - Specification Technical - View breakup
Hence complete testing charges for the product are Rs.4800.00
- -
-
11590 BIS, Northern Regional Laboratory (NRL) None IS 9523 (2000) Ductile iron fittings for pressure pipes for water, gas and sewage - Specification (First Revision) - Rs.7245.00 View breakup
-
- -
1 coated, 1 uncoated and separate sample for tensile and hardness test are required Except HST for DN above 300 mm
11591 BIS, Northern Regional Laboratory (NRL) None IS 7098 : Part 2 (2011) Crosslinked polyethylene insulated thermoplastic sheathed cables - Specification: Part 2 for working voltages from 3.3 kV up to and including 33 kV (Second Revision) - Rs. 33750/- View breakup
-
- -
Test facility is complete for Chemical Except Cl.20.9 Ageing Test on complete cable, Cl.20.2 Partial discharge, impulse , Cl.20.7 HVT(above 10 kV), Cl.20.3 bending test ,Cl.20.4 Dielectric power factor test ,Cl.20.5 Heat Cycle test,Cl.20.6 Impulse withstand test
11592 BIS, Western Regional Laboratory (WRL) None IS 8783 : Part 4 : Sec 3 (1995) Winding wires for submersible motors - Specification: Part 4 specification for individual wires: Sec 3 polyester and polypropylene insulated winding wires (First Revision) - Rs.8700/- View breakup
-
- -
The following test facilities for clauses are not available: Cl 4.1 Thickness of Insulation (Separate measurement of Thickness of Polypropylene and Polyester)
11593 BIS, Northern Regional Laboratory (NRL) None IS 1875 (1992) Carbon steel billets, blooms, slabs and bars for forgings - Specification (Fifth Revision) - Rs.5400/- View breakup
-
- -
Excluding Grain size, Microstructure,Microalloying Elements
11594 BIS, Western Regional Laboratory (WRL) None IS 8783 : Part 4 : Sec 1 (1995) Winding wires for submersible motors - Specification: Part 4 specification for indmdual wires: Sec 1 HR PVC insulated wires (First Revision) - 9300/- View breakup
-
- -
-
11595 BIS, Northern Regional Laboratory (NRL) None IS 1825 (1983) Specification for aluminium alloy milk cans (Second Revision) - Rs 4800.00 View breakup
-
- -
Test facility is complete, Facility for chemical testing is not available
11596 BIS, Eastern Regional Laboratory (ERL) None IS 15911 (2010) Structural steel (Ordinary Quality) - Specification All grades Rs 6750/- For elements other than Table-1: Rs 1004/- pe View breakup
-
- -
Chem- C, S, P, Mn, Si, Cu & N can only be carried out.Grade designation to be declared.
11597 BIS, Northern Regional Laboratory (NRL) None IS 4224 (1972) Specification for steel wire for staples, pins and clips (First Revision) - 525 View breakup
-
- -
Test facility is complete
11598 BIS, Western Regional Laboratory (WRL) None IS 7098 : Part 1 (1988) Specification for crosslinked polyethylene insulated pvc sheathed cables: Part 1 for working voltages up to and including 1100 volts (First Revision) Except C1 & C2 category. - View breakup
-
- -
Test facility not available for tests as per Clause 15.1.1 of C1 and C2 category
11599 BIS, Western Regional Laboratory (WRL) None IS 4250 (1980) Specification for domestic electric food - Mixers (Liquidizers And Grinders) (First Revision) - - View breakup
-
- -
The following test facilities are not available: 1. Cl.14 Transient Overvoltage test (as per IS 302-1) 2. Cl.19.11 and 19.12 Abnormal Operation test (as perIS 302-1) (for electronic circuit) 3. Cl 24 component test as per IS302-1
11600 BIS, Northern Regional Laboratory (NRL) None IS 7098 : Part 1 (1988) Specification for crosslinked polyethylene insulated pvc sheathed cables: Part 1 for working voltages up to and including 1100 volts (First Revision) - - View breakup
-
- -
Test facility is complete
11601 BIS, Western Regional Laboratory (WRL) None IS 3975 (1999) Low carbon galvanized steel wires, formed wires and tapes for armouring of cables - Specification (Third Revision) - Rs 2700/- View breakup
-
- -
Test facility not available for the following: 1) Dimension radius R of formed wire.
11602 BIS, Central Laboratory (CL) None IS 12176 (1987) Specification for sweetened ultra high temperature (UHT) treated condensed milk - - View breakup
-
- -
-Animal House; Excluding -MEASUREMENT OF SIZE AND COUNT OF LACTOSE CRYSTALS, Cl. 4.1.10.1;
11603 BIS, Western Regional Laboratory (WRL) None IS 2465 (1984) Specification for cables for motor vehicles (Second Revision) Complete test facility for PVC Insulated General Wiring Single core PVC Insulated Unsheathed: Rs. 11030/- View breakup
Single core PVC Insulated Sheathed: 75 % additional for sheath. Multi core with PVC Sheath: 75% additional for each additional core. Round and flat tinned copper braids without further covering for earthing: Rs. 1115/- Above charges are excluding Material tests, Ageing in oxygen bomb, Capacitance test, Ozone resistance test, Effect of heat on flexibility, Effect of oils, Effect of lubricating oil, brake fluid, diesel and petrol, Effect of cooling on flexibility.
- -
The following test facilities for ignition cables are not available: Cl 16 Capacitance, Cl 17 Ozone resistance, Cl 18 Effect of heat on flexibility, Cl 19 Effect of Oil test
11604 BIS, Western Regional Laboratory (WRL) None IS 1293 (2019) Plugs and socket - Outlets of rated Voltage up to and including 250 Volts and rated current up to and including 16 amperes - Specification (Third Revision) UP TO 16A, 250V - View breakup
-
- -
Complete Test facility available
11605 BIS, Central Laboratory (CL) None IS 8183 (1993) Bonded mineral wool - Specification (First Revision) - - View breakup
-
- -
-
11606 BIS, Western Regional Laboratory (WRL) None IS 398 : Part 5 (1992) Aluminium conductor for overhead transmission purposes - Specification: Part 5 aluminium conductors - Galvanized steel - Reinforced for extra high voltage (400 KV And Above) (First Revision) Except Test facility for clause 13.10, 13.11 and 13.12 11400 View breakup
Excluding Breaking load on complete conductor, Surface condition test, Corona test and Radio interference test
- -
Test facility not available: 1. Breaking Load Test on Complete Conductor, 2. Surface conditioning test apparatus 3. Corona Test 4. Radio Interference Voltage Test.
11607 BIS, Western Regional Laboratory (WRL) None IS 398 : Part 4 (1994) Aluminium conductors for overhead transmission purposes: Part 4 aluminium alloy stranded conductors (Aluminium - Magnesium - Silicon Type) - Specification (Third Revision) - Rs 825/- upto 7 wires, Rs 1425/- upto 19 wires View breakup
-
- -
Complete Test facility available
11608 BIS, Western Regional Laboratory (WRL) None IS 398 : Part 1 (1996) Aluminium conductors for overhead transmission purposes - Specification: Part 1 aluminium stranded conductors (Third Revision) - Rs.1600/- for 7 strands, Rs.3750/- for 19 strands View breakup
-
- -
Complete Test Facility
11609 BIS, Northern Regional Laboratory (NRL) None IS 651 (2007) Glazed stoneware pipes and fittings - Specification (Sixth Revision) - Rs. 6850/- View breakup
-
- -
Test facility is complete for Chemical Except HST and compression test For size above 300 mm
11610 BIS, Northern Regional Laboratory (NRL) None IS 458 (2003) Precast concrete pipes(With And Without Reinforcement) - Specification (Fourth Revision) - - View breakup
Rs.4200/- (excl. Split tensile strength test, Hydrostatic test, Three edge bearing test and test for aggregates) and testing charges as per relevant referred Iss
- -
Standard has been revised as IS 458 : 2021 Except three edge load and HST, Split tesnsile and compressive strength upto 1000KN load-