1 |
Conformity Testing Labs Pvt. Ltd. Unit 2
| IS 302 : Part 1 (2024) |
Household and Similar Electrical Appliances â Safety Part 1 General Requirements (Seventh Revision) |
- |
275000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
12(Charging of metal-ion batteries) |
- |
20000 |
|
Reduced Charges may apply for non complex Product depending upon parameters not applicable |
19.11.4.6(Class 3 Voltage dips and interruptions) |
- |
15000 |
|
Reduced Charges may apply for non complex Product depending upon parameters not applicable |
19.11.4.4(Surge immunity test) |
- |
15000 |
|
Reduced Charges may apply for non complex Product depending upon parameters not applicable |
19.11.4.3(Fast transient bursts) |
- |
15000 |
|
Reduced Charges may apply for non complex Product depending upon parameters not applicable |
19.11.4.1(Electrostatic discharges) |
- |
15000 |
|
Reduced Charges may apply for non complex Product depending upon parameters not applicable |
11.8(Temperature rise) |
- |
5000 |
|
Reduced Charges may apply for non complex Product depending upon parameters not applicable |
11.7(Duration corresponding) |
- |
5000 |
|
Reduced Charges may apply for non complex Product depending upon parameters not applicable |
11.6(Combined appliances) |
- |
5000 |
|
Reduced Charges may apply for non complex Product depending upon parameters not applicable |
11.5(Motor-operated appliances) |
- |
5000 |
|
Reduced Charges may apply for non complex Product depending upon parameters not applicable |
11.4(Heating appliances) |
- |
5000 |
|
Reduced Charges may apply for non complex Product depending upon parameters not applicable |
8.1.5(Live parts of built-in appliances) |
- |
5000 |
|
Reduced Charges may apply for non complex Product depending upon parameters not applicable |
17(Overload protection of transformers and associated circuits) |
- |
5000 |
|
Reduced Charges may apply for non complex Product depending upon parameters not applicable |
16(Leakage current and electric strength) |
- |
5000 |
|
Reduced Charges may apply for non complex Product depending upon parameters not applicable |
31(Resistance to Rusting) |
- |
5000 |
|
Reduced Charges may apply for non complex Product depending upon parameters not applicable |
30.2(Needle Flame Test) |
- |
5000 |
|
Reduced Charges may apply for non complex Product depending upon parameters not applicable |
30.2(Glow Wire Test) |
- |
5000 |
|
Reduced Charges may apply for non complex Product depending upon parameters not applicable |
30.1(Ball pressure test) |
- |
5000 |
|
Reduced Charges may apply for non complex Product depending upon parameters not applicable |
29(clearance, creepage distances and solid insulation) |
- |
5000 |
|
Reduced Charges may apply for non complex Product depending upon parameters not applicable |
28(Screw test and connections) |
- |
5000 |
|
Reduced Charges may apply for non complex Product depending upon parameters not applicable |
27(Provision for earthing) |
- |
5000 |
|
Reduced Charges may apply for non complex Product depending upon parameters not applicable |
26(Terminals for external conductors) |
- |
5000 |
|
Reduced Charges may apply for non complex Product depending upon parameters not applicable |
25(Supply connection and external flexible cords) |
- |
5000 |
|
Reduced Charges may apply for non complex Product depending upon parameters not applicable |
24(Components) |
- |
5000 |
|
Reduced Charges may apply for non complex Product depending upon parameters not applicable |
23(Internal wiring) |
- |
5000 |
|
Reduced Charges may apply for non complex Product depending upon parameters not applicable |
22(Construction) |
- |
85000 |
|
Reduced Charges may apply for non complex Product depending upon parameters not applicable |
20(Stability and mechanical hazards) |
- |
5000 |
|
Reduced Charges may apply for non complex Product depending upon parameters not applicable |
19(Abnormal Operation) |
- |
10000 |
|
Reduced Charges may apply for non complex Product depending upon parameters not applicable |
17(Over Load Protection of Transformers and associated circuits) |
- |
5000 |
|
Reduced Charges may apply for non complex Product depending upon parameters not applicable |
16.3(Electric Strength (after clause 15 and 16.2)) |
- |
5000 |
|
Reduced Charges may apply for non complex Product depending upon parameters not applicable |
16.2(Leakage Current (after Clause 15)) |
- |
5000 |
|
Reduced Charges may apply for non complex Product depending upon parameters not applicable |
16.1(General) |
- |
5000 |
|
Reduced Charges may apply for non complex Product depending upon parameters not applicable |
15.3(Humidity Test) |
- |
5000 |
|
Reduced Charges may apply for non complex Product depending upon parameters not applicable |
15.2(Spillage Test) |
- |
5000 |
|
Reduced Charges may apply for non complex Product depending upon parameters not applicable |
15.1(Ingress Protection test other than IPX0 (IP test)) |
- |
5000 |
|
Reduced Charges may apply for non complex Product depending upon parameters not applicable |
15.0(Moisture resistance) |
- |
7000 |
|
Reduced Charges may apply for non complex Product depending upon parameters not applicable |
14(Transient Over Voltages) |
- |
7000 |
|
Reduced Charges may apply for non complex Product depending upon parameters not applicable |
13.3(Electric Strength at operating temperature) |
- |
5000 |
|
Reduced Charges may apply for non complex Product depending upon parameters not applicable |
13.2(Leakage current at operating temperature) |
- |
5000 |
|
Reduced Charges may apply for non complex Product depending upon parameters not applicable |
13(Leakage current and electric strength at operating temperature) |
- |
10000 |
|
Reduced Charges may apply for non complex Product depending upon parameters not applicable |
11.3(Heating) |
- |
5000 |
|
Reduced Charges may apply for non complex Product depending upon parameters not applicable |
11.2(General) |
- |
5000 |
|
Reduced Charges may apply for non complex Product depending upon parameters not applicable |
11.1(General) |
- |
5000 |
|
Reduced Charges may apply for non complex Product depending upon parameters not applicable |
10.2(Current input) |
- |
5000 |
|
Reduced Charges may apply for non complex Product depending upon parameters not applicable |
10.1(Power input) |
- |
5000 |
|
Reduced Charges may apply for non complex Product depending upon parameters not applicable |
8.1.4(Protection against live parts against protective impedance) |
- |
5000 |
|
Reduced Charges may apply for non complex Product depending upon parameters not applicable |
8.1.3(Protection against live parts in visible glowing heating elements) |
- |
5000 |
|
Reduced Charges may apply for non complex Product depending upon parameters not applicable |
8.1.2(Protection against live parts in openings) |
- |
5000 |
|
Reduced Charges may apply for non complex Product depending upon parameters not applicable |
8.1.1(Protection against live parts in all positions) |
- |
5000 |
|
Reduced Charges may apply for non complex Product depending upon parameters not applicable |
7(Marking and instructions) |
- |
3000 |
|
Reduced Charges may apply for non complex Product depending upon parameters not applicable |
Annex C(Ageing test on motors) |
- |
5000 |
|
Reduced Charges may apply for non complex Product depending upon parameters not applicable |
15.2(Moisture resistance) |
- |
10000 |
|
Reduced Charges may apply for non complex Product depending upon parameters not applicable |
19.17(Abnormal operation) |
- |
10000 |
|
Reduced Charges may apply for non complex Product depending upon parameters not applicable |
20.1(Stability and mechanical hazards) |
- |
5000 |
|
Reduced Charges may apply for non complex Product depending upon parameters not applicable |
21.2(Mechanical strength) |
- |
5000 |
|
Reduced Charges may apply for non complex Product depending upon parameters not applicable |
21.3(Mechanical strength) |
- |
5000 |
|
Reduced Charges may apply for non complex Product depending upon parameters not applicable |
21(Mechanical Strength) |
- |
5000 |
|
Reduced Charges may apply for non complex Product depending upon parameters not applicable |
22.5(Construction) |
- |
5000 |
|
Reduced Charges may apply for non complex Product depending upon parameters not applicable |
22.6(Construction) |
- |
5000 |
|
Reduced Charges may apply for non complex Product depending upon parameters not applicable |
22.11(Construction) |
- |
5000 |
|
Reduced Charges may apply for non complex Product depending upon parameters not applicable |
22.16(Construction) |
- |
5000 |
|
Reduced Charges may apply for non complex Product depending upon parameters not applicable |
22.32(Construction) |
- |
5000 |
|
Reduced Charges may apply for non complex Product depending upon parameters not applicable |
22.42(Construction) |
- |
5000 |
|
Reduced Charges may apply for non complex Product depending upon parameters not applicable |
23.3(Internal wiring) |
- |
5000 |
|
Reduced Charges may apply for non complex Product depending upon parameters not applicable |
25(Supply connection and external flexible cords) |
- |
5000 |
|
Reduced Charges may apply for non complex Product depending upon parameters not applicable |
25.7(Supply connection and external flexible cords) |
- |
5000 |
|
Reduced Charges may apply for non complex Product depending upon parameters not applicable |
25.14(Supply connection and external flexible cords) |
- |
5000 |
|
Reduced Charges may apply for non complex Product depending upon parameters not applicable |
25.15(Supply connection and external flexible cords) |
- |
5000 |
|
Reduced Charges may apply for non complex Product depending upon parameters not applicable |
26.5(Terminals for external conductors) |
- |
5000 |
|
Reduced Charges may apply for non complex Product depending upon parameters not applicable |
27.5(Provision for earthing) |
- |
5000 |
|
Reduced Charges may apply for non complex Product depending upon parameters not applicable |
28.1(Screws and connections) |
- |
5000 |
|
Reduced Charges may apply for non complex Product depending upon parameters not applicable |
B.22.1(Construction) |
- |
5000 |
|
Reduced Charges may apply for non complex Product depending upon parameters not applicable |
B.22.3(Construction) |
- |
5000 |
|
Reduced Charges may apply for non complex Product depending upon parameters not applicable |
B.22.4(Construction) |
- |
5000 |
|
Reduced Charges may apply for non complex Product depending upon parameters not applicable |
B.22.5(Construction) |
- |
5000 |
|
Reduced Charges may apply for non complex Product depending upon parameters not applicable |
18(Endurance) |
- |
50000 |
|
Reduced Charges may apply for non complex Product depending upon parameters not applicable |
6(Classification) |
- |
5000 |
|
Reduced Charges may apply for non complex Product depending upon parameters not applicable |
5(General conditions for the tests) |
- |
5000 |
|
Reduced Charges may apply for non complex Product depending upon parameters not applicable |
4(General requirement) |
- |
5000 |
|
Reduced Charges may apply for non complex Product depending upon parameters not applicable |
9(Starting of motor operation test requirements and tests) |
- |
10000 |
|
Reduced Charges may apply for non complex Product depending upon parameters not applicable |
Annex D(Thermal motor protectors) |
- |
5000 |
|
Reduced Charges may apply for non complex Product depending upon parameters not applicable |
32(Radiation Toxicity and Similar Hazards) |
- |
5000 |
|
Reduced Charges may apply for non complex Product depending upon parameters not applicable |
A.2(Earth continuity test) |
- |
15000 |
|
Reduced Charges may apply for non complex Product depending upon parameters not applicable |
18(Endurance) |
- |
50000 |
|
Reduced Charges may apply for non complex Product depending upon parameters not applicable |
16.0(General) |
- |
5000 |
|
Reduced Charges may apply for non complex Product depending upon parameters not applicable |
|
05 Apr, 2027 |
- - |
2 |
Conformity Testing Labs Pvt. Ltd. Unit 2
| IS 302 : Part 2 : Sec 203 (1994) |
Safety of household and similar electrical appliances: Part 2 particular requirements: Sec 203 electric call bells and buzzers for indoor use |
- |
21500 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
5(Rating) |
- |
0 |
|
- |
6(Classification) |
- |
0 |
|
- |
7(Marking) |
- |
0 |
|
- |
8(Protection against Access to Live Parts) |
- |
0 |
|
- |
9(Starting Of Motor Operated Appliances) |
- |
0 |
|
- |
10("Power Input
& Current") |
- |
0 |
|
- |
11(Temperature Rise/ Heating) |
- |
0 |
|
- |
12(Operation Under Overload Conditions of Appliances with heating Element) |
- |
0 |
|
- |
13(Leakage Current and Electric Strength at Operating Temperature) |
- |
0 |
|
- |
14("Radio and Television Interference Suppression / Transient Over Voltage
") |
- |
0 |
|
- |
15(Moisture Resistance) |
- |
0 |
|
- |
16(Leakage Current and Electric Strength/ Insulation Resistance and Electric Strength (After Humidity treatment)) |
- |
0 |
|
- |
17(Overload Protection/ Overload Protection of Transformers & Associated Circuits) |
- |
0 |
|
- |
18(Endurance) |
- |
0 |
|
- |
19(Abnormal Operation) |
- |
0 |
|
- |
20(Stability & Mechanical Hazards) |
- |
0 |
|
- |
21(Mechanical strength) |
- |
0 |
|
- |
22(Construction) |
- |
0 |
|
- |
23(Internal Wiring) |
- |
0 |
|
- |
25(Supply Connection & External Flexible Cords) |
- |
0 |
|
- |
26(Terminals For External Conductors) |
- |
0 |
|
- |
27(Provision For Earthing) |
- |
0 |
|
- |
28(Screws & Connections) |
- |
0 |
|
- |
29(Clearances, Creepage Distances & Solid Insulation) |
- |
0 |
|
- |
30(Resistance to Heat & Fire) |
- |
0 |
|
- |
31(Resistance to Rusting) |
- |
0 |
|
- |
32(Radiation hazards) |
- |
0 |
|
- |
Cl 19.11.4.1(Electrostatic discharges) |
- |
0 |
|
- |
Cl 19.11.4.3(Fast transient bursts) |
- |
0 |
|
- |
Cl 19.11.4.4(Surge immunity test) |
- |
0 |
|
- |
Cl 19.11.4.6(Class 3 Voltage dips and interruptions) |
- |
0 |
|
- |
|
05 Apr, 2027 |
- Included w.e.f 20.06.2025 |
3 |
Samridhi Test House Pvt. Ltd.
| IS 302 : Part 1 (2024) |
Household and Similar Electrical Appliances â Safety Part 1 General Requirements (Seventh Revision) |
Household and Similar Electrical Appliances |
44500 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
12(Charging of metal-ion batteries) |
- |
0 |
|
Battery Analyzer |
6(Classification) |
- |
500 |
|
- |
5(General conditions for the tests) |
- |
500 |
|
- |
19.11.4.7(Harmonics) |
- |
0 |
|
EMI/EMC test facility not available |
19.11.4.6(Class 3 Voltage dips and interruptions) |
- |
0 |
|
EMI/EMC test facility not available |
19.11.4.5(Immunity to conducted discharges) |
- |
0 |
|
EMI/EMC test facility not available |
19.11.4.4(Surge immunity test) |
- |
0 |
|
EMI/EMC test facility not available |
19.11.4.3(Fast transient bursts) |
- |
0 |
|
EMI/EMC test facility not available |
19.11.4.2(Radiated fields) |
- |
0 |
|
EMI/EMC test facility not available |
19.11.4.1(Electrostatic discharges) |
- |
0 |
|
EMI/EMC test facility not available |
11.8(Temperature rise) |
- |
5000 |
|
- |
11.7(Duration corresponding) |
- |
2500 |
|
- |
11.6(Combined appliances) |
- |
2500 |
|
- |
11.5(Motor-operated appliances) |
- |
2500 |
|
- |
11.4(Heating appliances) |
- |
2500 |
|
- |
8.1.5(Live parts of built-in appliances) |
- |
2500 |
|
- |
18(Endurance) |
- |
1000 |
|
- |
17(Overload protection of transformers and associated circuits) |
- |
2000 |
|
- |
16(Leakage current and electric strength) |
- |
1000 |
|
- |
4(General requirement) |
- |
500 |
|
- |
32(Radiation Toxicity and Similar Hazards) |
- |
1000 |
|
- |
31(Resistance to Rusting) |
- |
1000 |
|
- |
30.2(Needle Flame Test) |
- |
1000 |
|
- |
30.2(Glow Wire Test) |
- |
1000 |
|
- |
30.1(Ball pressure test) |
- |
1000 |
|
- |
29(clearance, creepage distances and solid insulation) |
- |
2000 |
|
- |
28(Screw test and connections) |
- |
1000 |
|
- |
27(Provision for earthing) |
- |
2000 |
|
- |
26(Terminals for external conductors) |
- |
1000 |
|
- |
25(Supply connection and external flexible cords) |
- |
1000 |
|
- |
24(Components) |
- |
3000 |
|
- |
23(Internal wiring) |
- |
1000 |
|
- |
22(Construction) |
- |
5000 |
|
- |
21(Mechanical Strength) |
- |
2000 |
|
- |
20(Stability and mechanical hazards) |
- |
1000 |
|
- |
19(Abnormal Operation) |
- |
2000 |
|
- |
18(Endurance) |
- |
0 |
|
- |
17(Over Load Protection of Transformers and associated circuits) |
- |
0 |
|
- |
16.3(Electric Strength (after clause 15 and 16.2)) |
- |
1000 |
|
- |
16.2(Leakage Current (after Clause 15)) |
- |
1000 |
|
- |
16.1(General) |
- |
1000 |
|
- |
16.0(General) |
- |
3000 |
|
- |
15.3(Humidity Test) |
- |
1000 |
|
- |
15.2(Spillage Test) |
- |
1000 |
|
- |
15.1(Ingress Protection test other than IPX0 (IP test)) |
- |
4900 |
|
- |
15.0(Moisture resistance) |
- |
5000 |
|
- |
14(Transient Over Voltages) |
- |
1000 |
|
- |
13.3(Electric Strength at operating temperature) |
- |
1000 |
|
- |
13.2(Leakage current at operating temperature) |
- |
1000 |
|
- |
13(Leakage current and electric strength at operating temperature) |
- |
1000 |
|
- |
11.3(Heating) |
- |
1000 |
|
- |
11.2(General) |
- |
500 |
|
- |
11.1(General) |
- |
500 |
|
- |
10.2(Current input) |
- |
1000 |
|
- |
10.1(Power input) |
- |
1000 |
|
- |
9(Starting of motor operation test requirements and tests) |
- |
1000 |
|
- |
8.1.4(Protection against live parts against protective impedance) |
- |
1000 |
|
- |
8.1.3(Protection against live parts in visible glowing heating elements) |
- |
1000 |
|
- |
8.1.2(Protection against live parts in openings) |
- |
1000 |
|
- |
8.1.1(Protection against live parts in all positions) |
- |
1000 |
|
- |
7(Marking and instructions) |
- |
500 |
|
- |
A.2(Earth continuity test) |
- |
1000 |
|
- |
Annex C(Ageing test on motors) |
- |
1000 |
|
- |
Annex D(Thermal motor protectors) |
- |
1000 |
|
- |
15.2(Moisture resistance) |
- |
1000 |
|
- |
19.17(Abnormal operation) |
- |
1000 |
|
- |
20.1(Stability and mechanical hazards) |
- |
1000 |
|
- |
21.2(Mechanical strength) |
- |
1000 |
|
- |
21.3(Mechanical strength) |
- |
1000 |
|
- |
22.5(Construction) |
- |
0 |
|
EMI/EMC test facility not available. |
22.6(Construction) |
- |
1000 |
|
- |
22.11(Construction) |
- |
1000 |
|
- |
22.16(Construction) |
- |
1000 |
|
- |
22.32(Construction) |
- |
0 |
|
Oxygen Bomb with Pressure Gauge not available |
22.42(Construction) |
- |
1000 |
|
- |
23.3(Internal wiring) |
- |
1000 |
|
- |
25(Supply connection and external flexible cords) |
- |
5000 |
|
- |
25.7(Supply connection and external flexible cords) |
- |
0 |
|
- |
25.14(Supply connection and external flexible cords) |
- |
0 |
|
- |
25.15(Supply connection and external flexible cords) |
- |
0 |
|
- |
26.5(Terminals for external conductors) |
- |
1000 |
|
- |
27.5(Provision for earthing) |
- |
1000 |
|
- |
28.1(Screws and connections) |
- |
1000 |
|
- |
B.22.1(Construction) |
- |
1000 |
|
- |
B.22.3(Construction) |
- |
1000 |
|
- |
B.22.4(Construction) |
- |
1000 |
|
- |
B.22.5(Construction) |
- |
1000 |
|
EMI/EMC test facility not available |
12(Charging of metal-ion batteries) |
- |
0 |
|
- |
6(Classification) |
- |
0 |
|
- |
5(General conditions for the tests) |
- |
0 |
|
- |
19.11.4.7(Harmonics) |
- |
0 |
|
- |
19.11.4.6(Class 3 Voltage dips and interruptions) |
- |
0 |
|
- |
19.11.4.5(Immunity to conducted discharges) |
- |
0 |
|
- |
19.11.4.4(Surge immunity test) |
- |
0 |
|
- |
19.11.4.3(Fast transient bursts) |
- |
0 |
|
- |
19.11.4.2(Radiated fields) |
- |
0 |
|
- |
19.11.4.1(Electrostatic discharges) |
- |
0 |
|
- |
11.8(Temperature rise) |
- |
0 |
|
- |
11.7(Duration corresponding) |
- |
0 |
|
- |
11.6(Combined appliances) |
- |
0 |
|
- |
11.5(Motor-operated appliances) |
- |
0 |
|
- |
11.4(Heating appliances) |
- |
0 |
|
- |
8.1.5(Live parts of built-in appliances) |
- |
0 |
|
- |
18(Endurance) |
- |
0 |
|
- |
17(Overload protection of transformers and associated circuits) |
- |
0 |
|
- |
16(Leakage current and electric strength) |
- |
0 |
|
- |
4(General requirement) |
- |
0 |
|
- |
32(Radiation Toxicity and Similar Hazards) |
- |
0 |
|
- |
31(Resistance to Rusting) |
- |
0 |
|
- |
30.2(Needle Flame Test) |
- |
0 |
|
- |
30.2(Glow Wire Test) |
- |
0 |
|
- |
30.1(Ball pressure test) |
- |
0 |
|
- |
29(clearance, creepage distances and solid insulation) |
- |
0 |
|
- |
28(Screw test and connections) |
- |
0 |
|
- |
27(Provision for earthing) |
- |
0 |
|
- |
26(Terminals for external conductors) |
- |
0 |
|
- |
25(Supply connection and external flexible cords) |
- |
0 |
|
- |
24(Components) |
- |
0 |
|
- |
23(Internal wiring) |
- |
0 |
|
- |
22(Construction) |
- |
0 |
|
- |
21(Mechanical Strength) |
- |
0 |
|
- |
20(Stability and mechanical hazards) |
- |
0 |
|
- |
19(Abnormal Operation) |
- |
0 |
|
- |
18(Endurance) |
- |
0 |
|
- |
17(Over Load Protection of Transformers and associated circuits) |
- |
0 |
|
- |
16.3(Electric Strength (after clause 15 and 16.2)) |
- |
0 |
|
- |
16.2(Leakage Current (after Clause 15)) |
- |
0 |
|
- |
16.1(General) |
- |
0 |
|
- |
16.0(General) |
- |
0 |
|
- |
15.3(Humidity Test) |
- |
0 |
|
- |
15.2(Spillage Test) |
- |
0 |
|
- |
15.1(Ingress Protection test other than IPX0 (IP test)) |
- |
0 |
|
- |
15.0(Moisture resistance) |
- |
0 |
|
- |
14(Transient Over Voltages) |
- |
0 |
|
- |
13.3(Electric Strength at operating temperature) |
- |
0 |
|
- |
13.2(Leakage current at operating temperature) |
- |
0 |
|
- |
13(Leakage current and electric strength at operating temperature) |
- |
0 |
|
- |
11.3(Heating) |
- |
0 |
|
- |
11.2(General) |
- |
0 |
|
- |
11.1(General) |
- |
0 |
|
- |
10.2(Current input) |
- |
0 |
|
- |
10.1(Power input) |
- |
0 |
|
- |
9(Starting of motor operation test requirements and tests) |
- |
0 |
|
- |
8.1.4(Protection against live parts against protective impedance) |
- |
0 |
|
- |
8.1.3(Protection against live parts in visible glowing heating elements) |
- |
0 |
|
- |
8.1.2(Protection against live parts in openings) |
- |
0 |
|
- |
8.1.1(Protection against live parts in all positions) |
- |
0 |
|
- |
7(Marking and instructions) |
- |
0 |
|
- |
A.2(Earth continuity test) |
- |
0 |
|
- |
Annex C(Ageing test on motors) |
- |
0 |
|
- |
Annex D(Thermal motor protectors) |
- |
0 |
|
- |
15.2(Moisture resistance) |
- |
0 |
|
- |
19.17(Abnormal operation) |
- |
0 |
|
- |
20.1(Stability and mechanical hazards) |
- |
0 |
|
- |
21.2(Mechanical strength) |
- |
0 |
|
- |
21.3(Mechanical strength) |
- |
0 |
|
- |
22.5(Construction) |
- |
0 |
|
- |
22.6(Construction) |
- |
0 |
|
- |
22.11(Construction) |
- |
0 |
|
- |
22.16(Construction) |
- |
0 |
|
- |
22.32(Construction) |
- |
0 |
|
- |
22.42(Construction) |
- |
0 |
|
- |
23.3(Internal wiring) |
- |
0 |
|
- |
25(Supply connection and external flexible cords) |
- |
0 |
|
- |
25.7(Supply connection and external flexible cords) |
- |
0 |
|
- |
25.14(Supply connection and external flexible cords) |
- |
0 |
|
- |
25.15(Supply connection and external flexible cords) |
- |
0 |
|
- |
26.5(Terminals for external conductors) |
- |
0 |
|
- |
27.5(Provision for earthing) |
- |
0 |
|
- |
28.1(Screws and connections) |
- |
0 |
|
- |
B.22.1(Construction) |
- |
0 |
|
- |
B.22.3(Construction) |
- |
0 |
|
- |
B.22.4(Construction) |
- |
0 |
|
- |
B.22.5(Construction) |
- |
0 |
|
- |
|
09 Apr, 2028 |
- - |
4 |
EAMP Laboratories LLP
| IS 302 : Part 2 : Sec 26 (2014) |
Safety of household and similar electrical appliances: Part 2 particular requirements: Sec 26 clocks (First Revision) |
- |
20000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
7(Marking and instructions) |
- |
500 |
|
- |
8(Protection against live parts) |
- |
500 |
|
- |
10(POWER INPUT AND CURRENT) |
- |
2000 |
|
- |
11(HEATING) |
- |
500 |
|
- |
13(LEAKAGE CURRENT AND ELECTRIC STRENGTH AT OPERATING TEMPERATURE) |
- |
500 |
|
- |
14(TRANSIENT OVERVOLTAGES) |
- |
1000 |
|
- |
15(MOISTURE RESISTANCE) |
- |
2000 |
|
- |
16(LEAKAGE CURRENT AND ELECTRIC STRENGTH) |
- |
500 |
|
- |
17(OVERLOAD PROTECTION OF TRANSFORMERS AND ASSOCIATED CIRCUITS) |
- |
1000 |
|
- |
19(ABNORMAL OPERATION) |
- |
2000 |
|
- |
20(STABILITY AND MECHANICAL HAZARDS) |
- |
500 |
|
- |
21(MECHANICAL STRENGTH) |
- |
500 |
|
- |
22(CONSTRUCTION) |
- |
500 |
|
- |
6.0(Classification) |
- |
500 |
|
- |
23(INTERNAL WIRING) |
- |
500 |
|
- |
24(COMPONENTS) |
- |
500 |
|
- |
25(SUPPLY CONNECTION AND EXTERNAL FLEXIBLE CORDS) |
- |
500 |
|
- |
26(TERMINALS FOR EXTERNAL CONDUCTORS) |
- |
500 |
|
- |
27(PROVISION FOR EARTHING) |
- |
500 |
|
- |
28(SCREWS AND CONNECTIONS) |
- |
500 |
|
- |
29(CLEARANCES, CREEPAGE DISTANCES AND SOLID INSULATION) |
- |
500 |
|
- |
30(RESISTANCE TO HEAT AND FIRE) |
- |
1000 |
|
- |
31(RESISTANCE TO RUSTING) |
- |
500 |
|
- |
9(STARTING OF MOTOR-OPERATED APPLIANCES) |
- |
500 |
|
- |
4(General Requirements) |
- |
500 |
|
- |
5(General conditions for the tests) |
- |
500 |
|
- |
19.11.4.4(Surge immunity test) |
- |
1000 |
|
- |
|
13 Sep, 2025 |
- - |
5 |
EAMP Laboratories LLP
| IS 302 : Part 2 : Sec 6 (2009) |
Safety of household and similar electrical appliances: Part 2 particular requirements: Sec 6 cooking ranges, hobs, ovens and similar appliances (First Revision) |
- |
20000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
6.0(Classification) |
- |
500 |
|
- |
7.0(Marking and instructions) |
- |
500 |
|
- |
8.0(Protection against access to live part test) |
- |
500 |
|
- |
9.0(Starting of motor-operated appliances test) |
- |
500 |
|
- |
10.0(Power Input and current test) |
- |
500 |
|
- |
11.0(Heating test) |
- |
1000 |
|
- |
13.0(Leakage current and electric strength test) |
- |
1000 |
|
- |
14.0(Transient voltages) |
- |
2000 |
|
- |
15.0(Moisture Resistance) |
- |
2000 |
|
- |
16.0(Leakage current and electric strength test) |
- |
1000 |
|
- |
17.0(Overload protection of transformers test) |
- |
1000 |
|
- |
19.0(Abnormal Operations) |
- |
1000 |
|
- |
20.0(Stability and Mechanical Hazards) |
- |
500 |
|
- |
21.0(Mechanical Strength) |
- |
500 |
|
- |
22.0(Construction verification related tests) |
- |
500 |
|
- |
23.0(Internal wiring) |
- |
500 |
|
- |
24.0(Components) |
- |
500 |
|
- |
25.0(Supply connections and External Flexible Cords) |
- |
500 |
|
- |
26.0(Terminal for External Conductors) |
- |
500 |
|
- |
27.0(Provision for Earthing) |
- |
500 |
|
- |
28.0(Screws and connections) |
- |
500 |
|
- |
29.0(Clearances and Creepage distances and solid insulation) |
- |
500 |
|
- |
30.0(Resistance to heat and fire) |
- |
1000 |
|
- |
31.0(Resistance to rusting) |
- |
1000 |
|
- |
4(General Requirements) |
- |
250 |
|
- |
5(General condition for the tests) |
- |
250 |
|
- |
19.11.4.4(Surge immunity test) |
- |
1000 |
|
- |
|
13 Sep, 2025 |
- - |
6 |
EAMP Laboratories LLP
| IS 302 : Part 1 (2008) |
Safety of household and similar electrical appliances: Part 1 general requirements (Sixth Revision) |
Adapters for household and similar electrical appliance |
15000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
7(Marking and instructions) |
- |
200 |
|
Household and similar electrical appliances |
8.1.1(Protection against live parts in all positions) |
- |
300 |
|
Household and similar electrical appliances |
8.1.2(Protection against live parts in openings) |
- |
300 |
|
Household and similar electrical appliances |
8.1.3(Protection against live parts in visible glowing heating elements) |
- |
300 |
|
Household and similar electrical appliances |
8.1.4(Protection against live parts against protective impedance) |
- |
300 |
|
Household and similar electrical appliances |
10.1(Power input) |
- |
500 |
|
Household and similar electrical appliances |
10.2(Current input) |
- |
500 |
|
Household and similar electrical appliances |
11.1(General) |
- |
0 |
|
Household and similar electrical appliances |
11.2(General) |
- |
0 |
|
Household and similar electrical appliances |
11.3(Heating) |
- |
300 |
|
Household and similar electrical appliances |
13.1(General) |
- |
0 |
|
Household and similar electrical appliances |
13.2(Leakage current at operating temperature) |
- |
400 |
|
Household and similar electrical appliances |
13.3(Electric Strength at operating temperature) |
- |
400 |
|
Household and similar electrical appliances |
14(Transient Over Voltages) |
- |
400 |
|
Household and similar electrical appliances |
15.0(General) |
- |
0 |
|
Household and similar electrical appliances |
15.1(Ingress Protection test other than IPX0 (IP test)) |
- |
300 |
|
Household and similar electrical appliances |
15.2(Spillage Test) |
- |
500 |
|
Household and similar electrical appliances |
15.3(Humidity Test) |
- |
400 |
|
Household and similar electrical appliances |
16.0(General) |
- |
200 |
|
Household and similar electrical appliances |
16.2(Leakage Current (after Clause 15)) |
- |
200 |
|
Household and similar electrical appliances |
16.3(Electric Strength (after clause 15 and 16.2)) |
- |
200 |
|
Household and similar electrical appliances |
17(Overload protection of transformers and associated circuits) |
- |
400 |
|
Household and similar electrical appliances |
19(Abnormal Operation) |
- |
400 |
|
Household and similar electrical appliances |
20(Stability test) |
- |
300 |
|
Household and similar electrical appliances |
21(Mechanical Strength Test) |
- |
300 |
|
Household and similar electrical appliances |
22(Construction verification related test) |
- |
300 |
|
Household and similar electrical appliances |
23(General) |
- |
300 |
|
Household and similar electrical appliances |
24(Components) |
- |
500 |
|
Household and similar electrical appliances |
25(Supply connection and external flexible cords) |
- |
300 |
|
Household and similar electrical appliances |
26(Terminals for external conductors) |
- |
200 |
|
Household and similar electrical appliances |
27(Provision for earthing) |
- |
300 |
|
Household and similar electrical appliances |
28(Screw test and connections) |
- |
200 |
|
Household and similar electrical appliances |
29(clearance, creepage distances and solid insulation) |
- |
200 |
|
Household and similar electrical appliances |
30.1(Ball pressure test) |
- |
200 |
|
Household and similar electrical appliances |
30.2(Glow Wire Test) |
- |
200 |
|
Household and similar electrical appliances |
30.2(Needle Flame Test) |
- |
200 |
|
Household and similar electrical appliances |
31(Resistance to Rusting) |
- |
300 |
|
Household and similar electrical appliances |
8.1.5(Live parts of built-in appliances) |
- |
500 |
|
Household and similar electrical appliances |
11.4(Heating appliances) |
- |
500 |
|
Household and similar electrical appliances |
11.5(Motor-operated appliances) |
- |
500 |
|
Household and similar electrical appliances |
11.6(Combined appliances) |
- |
500 |
|
Household and similar electrical appliances |
11.7(Duration corresponding) |
- |
500 |
|
Household and similar electrical appliances |
11.8(Temperature rise) |
- |
500 |
|
Household and similar electrical appliances |
9(Starting of motor operation test requirements and tests) |
- |
500 |
|
Household and similar electrical appliances |
16.1(General) |
- |
200 |
|
Household and similar electrical appliances |
4(General Requirement) |
- |
250 |
|
Household and similar electrical appliances |
5(General conditions for tests) |
- |
250 |
|
Household and similar electrical appliances |
6(Classifications) |
- |
200 |
|
Household and similar electrical appliances |
19.11.4.4(Surge immunity test) |
- |
300 |
|
Household and similar electrical appliances |
|
13 Sep, 2025 |
- - |
7 |
Nemko India (Test Lab) Pvt. Ltd.
| IS 302 : Part 1 (2024) |
Household and Similar Electrical Appliances â Safety Part 1 General Requirements (Seventh Revision) |
- |
240000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
12(Charging of metal-ion batteries) |
- |
2000 |
|
10% (Discount offered to BIS) |
6(Classification) |
- |
0 |
|
-- |
5(General conditions for the tests) |
- |
0 |
|
-- |
11.8(Temperature rise) |
- |
5000 |
|
10% (Discount offered to BIS) |
11.7(Duration corresponding) |
- |
0 |
|
Refer cl. no. 11.8 |
11.6(Combined appliances) |
- |
0 |
|
Refer cl. no. 11.8 |
11.5(Motor-operated appliances) |
- |
0 |
|
Refer cl. no. 11.8 |
11.4(Heating appliances) |
- |
0 |
|
Refer cl. no. 11.8 |
8.1.5(Live parts of built-in appliances) |
- |
2000 |
|
10% (Discount offered to BIS) |
17(Overload protection of transformers and associated circuits) |
- |
2000 |
|
10% (Discount offered to BIS) |
16(Leakage current and electric strength) |
- |
3000 |
|
10% (Discount offered to BIS) |
4(General requirement) |
- |
0 |
|
-- |
31(Resistance to Rusting) |
- |
2000 |
|
10% (Discount offered to BIS) |
30.2(Needle Flame Test) |
- |
3000 |
|
10% (Discount offered to BIS) |
30.2(Glow Wire Test) |
- |
3000 |
|
10% (Discount offered to BIS) |
30.1(Ball pressure test) |
- |
2000 |
|
10% (Discount offered to BIS) |
29(clearance, creepage distances and solid insulation) |
- |
3000 |
|
10% (Discount offered to BIS) |
28(Screw test and connections) |
- |
2000 |
|
10% (Discount offered to BIS) |
27(Provision for earthing) |
- |
2000 |
|
10% (Discount offered to BIS) |
26(Terminals for external conductors) |
- |
2000 |
|
10% (Discount offered to BIS) |
25(Supply connection and external flexible cords) |
- |
2000 |
|
10% (Discount offered to BIS) |
23(Internal wiring) |
- |
2000 |
|
10% (Discount offered to BIS) |
22(Construction) |
- |
2000 |
|
10% (Discount offered to BIS) |
21(Mechanical Strength) |
- |
2000 |
|
10% (Discount offered to BIS) |
20(Stability and mechanical hazards) |
- |
2000 |
|
10% (Discount offered to BIS) |
19(Abnormal Operation) |
- |
5000 |
|
10% (Discount offered to BIS) |
16.3(Electric Strength (after clause 15 and 16.2)) |
- |
0 |
|
Refer cl. no. 16 |
16.2(Leakage Current (after Clause 15)) |
- |
0 |
|
Refer cl. no. 16 |
16.1(General) |
- |
0 |
|
Refer cl. no. 16 |
16.0(General) |
- |
0 |
|
Refer cl. no. 16 |
15.3(Humidity Test) |
- |
0 |
|
Refer cl. no. 15.0 |
15.2(Spillage Test) |
- |
0 |
|
Refer cl. no. 15.0 |
15.1(Ingress Protection test other than IPX0 (IP test)) |
- |
0 |
|
Refer cl. no. 15.0 |
15.0(Moisture resistance) |
- |
10000 |
|
10% (Discount offered to BIS) |
14(Transient Over Voltages) |
- |
2000 |
|
10% (Discount offered to BIS) |
13.3(Electric Strength at operating temperature) |
- |
0 |
|
Refer cl. no. 13 |
13.2(Leakage current at operating temperature) |
- |
0 |
|
Refer cl. no. 13 |
13(Leakage current and electric strength at operating temperature) |
- |
2000 |
|
10% (Discount offered to BIS) |
11.3(Heating) |
- |
0 |
|
Refer cl. no. 11.8 |
11.2(General) |
- |
0 |
|
Refer cl. no. 11.8 |
11.1(General) |
- |
0 |
|
Refer cl. no. 11.8 |
10.2(Current input) |
- |
5000 |
|
10% (Discount offered to BIS) |
10.1(Power input) |
- |
0 |
|
Refer cl. no. 10.2 |
8.1.4(Protection against live parts against protective impedance) |
- |
0 |
|
Refer cl. no. 8.1.1. |
8.1.3(Protection against live parts in visible glowing heating elements) |
- |
0 |
|
Refer cl. no. 8.1.1. |
8.1.2(Protection against live parts in openings) |
- |
0 |
|
Refer cl. no. 8.1.1. |
8.1.1(Protection against live parts in all positions) |
- |
2000 |
|
10% (Discount offered to BIS) |
7(Marking and instructions) |
- |
1000 |
|
10% (Discount offered to BIS) |
A.2(Earth continuity test) |
- |
2000 |
|
10% (Discount offered to BIS) |
Annex C(Ageing test on motors) |
- |
2000 |
|
10% (Discount offered to BIS) |
Annex D(Thermal motor protectors) |
- |
2000 |
|
10% (Discount offered to BIS) |
15.2(Moisture resistance) |
- |
0 |
|
Refer cl. no.: 15.0 |
19.17(Abnormal operation) |
- |
0 |
|
Refer cl. no.: 19 |
20.1(Stability and mechanical hazards) |
- |
0 |
|
Refer cl. no.: 20 |
21.2(Mechanical strength) |
- |
0 |
|
Refer cl. no.: 21 |
21.3(Mechanical strength) |
- |
0 |
|
Refer cl. no.: 21 |
22.5(Construction) |
- |
0 |
|
Refer cl. no.: 22 |
22.6(Construction) |
- |
0 |
|
Refer cl. no.: 22 |
22.11(Construction) |
- |
0 |
|
Refer cl. no.: 22 |
22.42(Construction) |
- |
0 |
|
Refer cl. no.: 22 |
23.3(Internal wiring) |
- |
0 |
|
Refer cl. no.: 23 |
25(Supply connection and external flexible cords) |
- |
0 |
|
Repeated clause. |
25.7(Supply connection and external flexible cords) |
- |
0 |
|
Refer cl. no.: 25 |
25.14(Supply connection and external flexible cords) |
- |
0 |
|
Refer cl. no.: 25 |
25.15(Supply connection and external flexible cords) |
- |
0 |
|
Refer cl. no.: 25 |
26.5(Terminals for external conductors) |
- |
0 |
|
Refer cl. no.: 26 |
27.5(Provision for earthing) |
- |
0 |
|
Refer cl. no.: 27 |
28.1(Screws and connections) |
- |
0 |
|
Refer cl. no.: 28 |
B.22.1(Construction) |
- |
2000 |
|
10% (Discount offered to BIS) |
B.22.3(Construction) |
- |
0 |
|
Refer cl. no. B.22.1 |
B.22.4(Construction) |
- |
0 |
|
Refer cl. no. B.22.1 |
B.22.5(Construction) |
- |
0 |
|
Refer cl. no. B.22.1 |
19.11.4.6(Class 3 Voltage dips and interruptions) |
- |
20000 |
|
10% (Discount offered to BIS) |
19.11.4.5(Immunity to conducted discharges) |
- |
20000 |
|
10% (Discount offered to BIS) |
19.11.4.4(Surge immunity test) |
- |
15000 |
|
10% (Discount offered to BIS) |
19.11.4.3(Fast transient bursts) |
- |
15000 |
|
10% (Discount offered to BIS) |
19.11.4.2(Radiated fields) |
- |
40000 |
|
10% (Discount offered to BIS) |
19.11.4.1(Electrostatic discharges) |
- |
20000 |
|
10% (Discount offered to BIS) |
18(Endurance) |
- |
1000 |
|
10% (Discount offered to BIS) |
17(Over Load Protection of Transformers and associated circuits) |
- |
0 |
|
Repeated clause. |
18(Endurance) |
- |
0 |
|
Repeated clause. |
9(Starting of motor operation test requirements and tests) |
- |
1000 |
|
10% (Discount offered to BIS) |
19.11.4.7(Harmonics) |
- |
40000 |
|
10% (Discount offered to BIS) |
|
31 Dec, 2026 |
- Included w.e.f 25.03.2025
Exclusion Cl 24 (Components), Cl 32 (Radiation Toxicity and Similar Hazards), Cl. 22.16, Cord reels test, Cl. 22.32, Oxygen bomb test |
8 |
ALPHA TEST HOUSE PVT LTD
| IS 302 : Part 2 : Sec 6 (2009) |
Safety of household and similar electrical appliances: Part 2 particular requirements: Sec 6 cooking ranges, hobs, ovens and similar appliances (First Revision) |
- |
105000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
6.0(Classification) |
- |
25000 |
|
Extra EMI/EMC charges: 1,80,000 |
7.0(Marking and instructions) |
- |
25000 |
|
Extra EMI/EMC charges: 1,80,000 |
8.0(Protection against access to live part test) |
- |
25000 |
|
Extra EMI/EMC charges: 1,80,000 |
10.0(Power Input and current test) |
- |
25000 |
|
Extra EMI/EMC charges: 1,80,000 |
11.0(Heating test) |
- |
25000 |
|
Extra EMI/EMC charges: 1,80,000 |
13.0(Leakage current and electric strength test) |
- |
25000 |
|
Extra EMI/EMC charges: 1,80,000 |
14.0(Transient voltages) |
- |
25000 |
|
Extra EMI/EMC charges: 1,80,000 |
15.0(Moisture Resistance) |
- |
25000 |
|
Extra EMI/EMC charges: 1,80,000 |
16.0(Leakage current and electric strength test) |
- |
25000 |
|
Extra EMI/EMC charges: 1,80,000 |
17.0(Overload protection of transformers test) |
- |
25000 |
|
Extra EMI/EMC charges: 1,80,000 |
19.0(Abnormal Operations) |
- |
25000 |
|
Extra EMI/EMC charges: 1,80,000 |
20.0(Stability and Mechanical Hazards) |
- |
25000 |
|
Extra EMI/EMC charges: 1,80,000 |
21.0(Mechanical Strength) |
- |
25000 |
|
Extra EMI/EMC charges: 1,80,000 |
22.0(Construction verification related tests) |
- |
25000 |
|
Extra EMI/EMC charges: 1,80,000 |
23.0(Internal wiring) |
- |
25000 |
|
Extra EMI/EMC charges: 1,80,000 |
24.0(Components) |
- |
25000 |
|
Extra EMI/EMC charges: 1,80,000 |
25.0(Supply connections and External Flexible Cords) |
- |
25000 |
|
Extra EMI/EMC charges: 1,80,000 |
26.0(Terminal for External Conductors) |
- |
25000 |
|
Extra EMI/EMC charges: 1,80,000 |
27.0(Provision for Earthing) |
- |
25000 |
|
Extra EMI/EMC charges: 1,80,000 |
28.0(Screws and connections) |
- |
25000 |
|
Extra EMI/EMC charges: 1,80,000 |
29.0(Clearances and Creepage distances and solid insulation) |
- |
25000 |
|
Extra EMI/EMC charges: 1,80,000 |
30.0(Resistance to heat and fire) |
- |
25000 |
|
Extra EMI/EMC charges: 1,80,000 |
31.0(Resistance to rusting) |
- |
25000 |
|
Extra EMI/EMC charges: 1,80,000 |
32.0(Radiation, Toxicity and Similar hazards) |
- |
25000 |
|
Extra EMI/EMC charges: 1,80,000 |
19.11.4.1(Electrostatic discharges) |
- |
180000 |
|
- |
19.11.4.2(Radiated fields) |
- |
180000 |
|
- |
19.11.4.3(Fast transient bursts) |
- |
180000 |
|
- |
19.11.4.4(Surge immunity test) |
- |
180000 |
|
- |
19.11.4.5(Immunity to conducted discharges) |
- |
180000 |
|
- |
19.11.4.6(Class 3 Voltage dips and interruptions) |
- |
180000 |
|
- |
19.11.4.7(Harmonics) |
- |
180000 |
|
- |
4(General Requirements) |
- |
25000 |
|
Extra EMI/EMC charges: 1,80,000 |
5(General condition for the tests) |
- |
25000 |
|
Extra EMI/EMC charges: 1,80,000 |
9.0(Starting of motor-operated appliances test) |
- |
0 |
|
- |
18.0(Endurance test) |
- |
0 |
|
- |
|
08 May, 2028 |
- Included w.e.f 20.06.2025 |
9 |
HT Product Services Private Limited
| IS 302 : Part 2 : Sec 4 (1993) |
Safety of household and similar electrical appliances: Part 2 particular requirements: Sec 4 spin extractors |
- |
50000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
3(GENERAL REQUIREMENTS) |
- |
1000 |
|
- |
4(GENERAL NOTES ON TESTS) |
- |
1000 |
|
- |
5(RATING) |
- |
1000 |
|
- |
6(CLASSIFICATION) |
- |
1000 |
|
- |
7(MARKING) |
- |
2000 |
|
- |
8(PROTECTION AGAINST ELECTRIC SHOCK) |
- |
2000 |
|
- |
9(STARTING OF MOTOR-OPERATED APPLIANCES) |
- |
1000 |
|
- |
10(INPUT AND CURRENT) |
- |
5000 |
|
- |
11(HEATING) |
- |
5000 |
|
- |
13(ELECTRICAL INSULATION AND LEAKAGE CURRENT AT OPERATING TEMPERATURE) |
- |
2000 |
|
- |
14(RADIO AND TELEVISION INTERFERENCE SUPPRESSION) |
- |
1000 |
|
- |
15(MOISTURE RESISTANCE) |
- |
5000 |
|
- |
16(INSULATION RESISTANCE AND ELECTRIC STRENGTH (AFTER HUMIDITY TREATMENT)) |
- |
2000 |
|
- |
17(OVERLOAD PROTECTION) |
- |
2000 |
|
- |
19(ABNORMAL OPERATION) |
- |
1000 |
|
- |
20(STABILITY AND MECHANICAL HAZARDS) |
- |
2000 |
|
- |
21(MECHANICAL STRENGTH) |
- |
2000 |
|
- |
22(CONSTRUCTION) |
- |
1000 |
|
- |
23(INTERNAL WIRING) |
- |
1000 |
|
- |
24(COMPONENTS) |
- |
2000 |
|
- |
25(SUPPLY CONNECTION AND EXTERNAL FLEXIBLE CABLES AND CORDS) |
- |
1000 |
|
- |
26(TERMINALS FOR EXTERNAL CONDUCTORS) |
- |
2000 |
|
- |
27(PROVISION FOR EARTHING) |
- |
2000 |
|
- |
28(SCREWS AND CONNECTIONS) |
- |
2000 |
|
- |
29(CREEPAGE DISTANCES, CLEARANCES AND DISTANCES THROUGH INSULATION) |
- |
1000 |
|
- |
30(RESISTANCE TO HEAT, FIRE AND TRACKING) |
- |
1000 |
|
- |
31(RESISTANCE TO RUSTING) |
- |
1000 |
|
- |
|
03 Dec, 2026 |
- Included w.e.f 09.06.2025 Exclusion: Cl 19.11.4.1-19.11.4.7 (EMI/EMC) |
10 |
ALPHA TEST HOUSE PVT LTD
| IS 302 : Part 2 : Sec 7 (2010) |
Safety of household and similar electrical appliances: Part 2 particular requirements: Sec 7 domestic electric clothes washing machines (First Revision) |
- |
235000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
32(Radiation ,Toxicity and similar hazards) |
- |
55000 |
|
Extra EMI/EMC charges: 1,80,000 |
31(Resistance to Rusting) |
- |
55000 |
|
Extra EMI/EMC charges: 1,80,000 |
30(Resistance to Heat & Fire) |
- |
55000 |
|
Extra EMI/EMC charges: 1,80,000 |
29(Clearances, Creepage Distances & Solid Insulation) |
- |
55000 |
|
Extra EMI/EMC charges: 1,80,000 |
28(Screws & Connections) |
- |
55000 |
|
Extra EMI/EMC charges: 1,80,000 |
27(Provision For Earthing) |
- |
55000 |
|
Extra EMI/EMC charges: 1,80,000 |
26(Terminals For External Conductors) |
- |
55000 |
|
Extra EMI/EMC charges: 1,80,000 |
25(Supply Connection & External Flexible Cords) |
- |
55000 |
|
Extra EMI/EMC charges: 1,80,000 |
24(Components) |
- |
55000 |
|
Extra EMI/EMC charges: 1,80,000 |
23(Internal wiring) |
- |
55000 |
|
Extra EMI/EMC charges: 1,80,000 |
22(Construction) |
- |
55000 |
|
Extra EMI/EMC charges: 1,80,000 |
21(Mechanical strength) |
- |
55000 |
|
Extra EMI/EMC charges: 1,80,000 |
20(Stability & Mechanical Hazards) |
- |
55000 |
|
Extra EMI/EMC charges: 1,80,000 |
19(Abnormal Operation) |
- |
55000 |
|
Extra EMI/EMC charges: 1,80,000 |
17(Overload Protection/ Overload Protection of Transformers & Associated Circuits) |
- |
55000 |
|
Extra EMI/EMC charges: 1,80,000 |
16(Leakage Current and Electric Strength) |
- |
55000 |
|
Extra EMI/EMC charges: 1,80,000 |
15(Moisture Resistance) |
- |
55000 |
|
Extra EMI/EMC charges: 1,80,000 |
14(Transient Over Voltage) |
- |
55000 |
|
Extra EMI/EMC charges: 1,80,000 |
13(Leakage Current and Electric Strength at Operating Temperature) |
- |
55000 |
|
Extra EMI/EMC charges: 1,80,000 |
11(Temperature Rise/ Heating) |
- |
55000 |
|
Extra EMI/EMC charges: 1,80,000 |
10(Power Input
& Current
) |
- |
55000 |
|
Extra EMI/EMC charges: 1,80,000 |
8(Protection against access to live parts) |
- |
55000 |
|
Extra EMI/EMC charges: 1,80,000 |
7(Marking) |
- |
55000 |
|
Extra EMI/EMC charges: 1,80,000 |
6(Classification) |
- |
55000 |
|
Extra EMI/EMC charges: 1,80,000 |
19.11.4.1(Electrostatic discharges) |
- |
180000 |
|
- |
19.11.4.2(Radiated fields) |
- |
180000 |
|
- |
19.11.4.3(Fast transient bursts) |
- |
180000 |
|
- |
19.11.4.4(Surge immunity test) |
- |
180000 |
|
- |
19.11.4.5(Immunity to conducted discharges) |
- |
180000 |
|
- |
19.11.4.6(Voltage dips and interruptions) |
- |
180000 |
|
- |
19.11.4.7(Harmonics) |
- |
180000 |
|
- |
5(GENERAL CONDITIONS FOR THE TESTS) |
- |
55000 |
|
Extra EMI/EMC charges: 1,80,000 |
4(GENERAL REQUIREMENTS) |
- |
55000 |
|
Extra EMI/EMC charges: 1,80,000 |
24.1.4(Endurance of lid or door interlocks) |
- |
55000 |
|
Extra EMI/EMC charges: 1,80,000 |
24.101(Thermal Cut-outs incorporated in compliance with Clause 19.4 shall no be self-resetting.) |
- |
55000 |
|
Extra EMI/EMC charges: 1,80,000 |
9(Starting of Motor operated appliances) |
- |
0 |
|
- |
18(Endurance) |
- |
55000 |
|
Extra EMI/EMC charges: 1,80,000 |
|
08 May, 2028 |
- Included w.e.f.19.06.2025 |
11 |
HT Product Services Private Limited
| IS 302 : Part 2 : Sec 206 (1994) |
Safety of household and similar electrical appliances: Part 2 particular requirements: Sec 206 electric coffee makers |
- |
30000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
32(Radiation hazards) |
- |
1000 |
|
- |
31(Resistance to Rusting) |
- |
1000 |
|
- |
30(Resistance to Heat, Fire and Tracking) |
- |
1000 |
|
- |
29(Clearances, Creepage Distances & Solid Insulation) |
- |
1000 |
|
- |
28(Screws & Connection) |
- |
1000 |
|
- |
27(Provision For Earthing) |
- |
1000 |
|
- |
26(Terminals For External Conductors) |
- |
1000 |
|
- |
25(Supply Connection & External Flexible Cables and Cords) |
- |
1000 |
|
- |
24(Component) |
- |
1000 |
|
- |
23(Internal wiring) |
- |
1000 |
|
- |
22(Construction) |
- |
1000 |
|
- |
21(Mechanical strength) |
- |
1000 |
|
- |
20(Stability & Mechanical Hazards) |
- |
1000 |
|
- |
19(Abnormal Operation) |
- |
1000 |
|
- |
18(Endurance) |
- |
1000 |
|
- |
17(Overload Protection) |
- |
1000 |
|
- |
16(Insulation resistance and Electric Strength (After humidity treatment)) |
- |
1000 |
|
- |
15(Moisture Resistance) |
- |
2000 |
|
- |
14(Radio and television interference suppression/ Transient Overvoltages) |
- |
1000 |
|
- |
13(Electrical insulation and Leakage Current at Operating Temperature) |
- |
1000 |
|
- |
12(Operation under overload conditions of appliances with heating elements) |
- |
1000 |
|
- |
11(Temperature Rise/Heating) |
- |
1000 |
|
- |
10(Input) |
- |
2000 |
|
- |
9(Starting Of Motor Operated Appliances) |
- |
1000 |
|
- |
8(Protection against Electric Shock/ Protection against Access to Live Parts) |
- |
1000 |
|
- |
7(Marking/ Marking & Instructions) |
- |
1000 |
|
- |
6(Classification) |
- |
1000 |
|
- |
5(Rating) |
- |
1000 |
|
- |
|
03 Dec, 2026 |
- Included w.e.f 09.06.2025 Exclusion: Cl 19.11.4.1-19.11.4.7 (EMI/EMC), |
12 |
HT Product Services Private Limited
| IS 302 : Part 2 : Sec 203 (1994) |
Safety of household and similar electrical appliances: Part 2 particular requirements: Sec 203 electric call bells and buzzers for indoor use |
- |
25000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
5(Rating) |
- |
1000 |
|
- |
6(Classification) |
- |
1000 |
|
- |
7(Marking) |
- |
1000 |
|
- |
8(Protection against Access to Live Parts) |
- |
1000 |
|
- |
9(Starting Of Motor Operated Appliances) |
- |
1000 |
|
- |
10("Power Input
& Current") |
- |
1000 |
|
- |
11(Temperature Rise/ Heating) |
- |
1000 |
|
- |
12(Operation Under Overload Conditions of Appliances with heating Element) |
- |
1000 |
|
- |
13(Leakage Current and Electric Strength at Operating Temperature) |
- |
1000 |
|
- |
14("Radio and Television Interference Suppression / Transient Over Voltage
") |
- |
1000 |
|
- |
15(Moisture Resistance) |
- |
1000 |
|
- |
16(Leakage Current and Electric Strength/ Insulation Resistance and Electric Strength (After Humidity treatment)) |
- |
1000 |
|
- |
17(Overload Protection/ Overload Protection of Transformers & Associated Circuits) |
- |
1000 |
|
- |
18(Endurance) |
- |
1000 |
|
- |
19(Abnormal Operation) |
- |
1000 |
|
- |
20(Stability & Mechanical Hazards) |
- |
1000 |
|
- |
21(Mechanical strength) |
- |
1000 |
|
- |
22(Construction) |
- |
1000 |
|
- |
23(Internal Wiring) |
- |
1000 |
|
- |
24(Components) |
- |
1000 |
|
- |
25(Supply Connection & External Flexible Cords) |
- |
1000 |
|
- |
26(Terminals For External Conductors) |
- |
1000 |
|
- |
27(Provision For Earthing) |
- |
1000 |
|
- |
28(Screws & Connections) |
- |
1000 |
|
- |
29(Clearances, Creepage Distances & Solid Insulation) |
- |
1000 |
|
- |
30(Resistance to Heat & Fire) |
- |
1000 |
|
- |
31(Resistance to Rusting) |
- |
1000 |
|
- |
32(Radiation hazards) |
- |
1000 |
|
- |
|
03 Dec, 2026 |
- Included w.e.f 09.06.2025 Exclusion: Cl 19.11.4.1-19.11.4.7 (EMI/EMC) |
13 |
ALPHA TEST HOUSE PVT LTD
| IS 302 : Part 2 : Sec 80 (2017) |
Household and similar electrical appliances - Safety: Part 2 - 80 particular requirements for fans (First Revision) |
- |
208300 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
32.0(Radiation, Toxicity and Similar Hazards) |
- |
28300 |
|
Extra EMI/EMC charges: 1,80,000 |
31.0(Resistance To Rusting) |
- |
28300 |
|
Extra EMI/EMC charges: 1,80,000 |
30.0(Resistance To Heat and Fire) |
- |
28300 |
|
Extra EMI/EMC charges: 1,80,000 |
29.0(Creepage Distances and Clearances) |
- |
28300 |
|
Extra EMI/EMC charges: 1,80,000 |
28.0(Screws and Connections) |
- |
28300 |
|
Extra EMI/EMC charges: 1,80,000 |
27.0(Provision For Earthing) |
- |
28300 |
|
Extra EMI/EMC charges: 1,80,000 |
26.0(Terminals for external conductors) |
- |
28300 |
|
Extra EMI/EMC charges: 1,80,000 |
25.0(Supply Connection and External Flexible Cords) |
- |
28300 |
|
Extra EMI/EMC charges: 1,80,000 |
24.0(Components) |
- |
28300 |
|
Extra EMI/EMC charges: 1,80,000 |
23.0(Internal Wiring) |
- |
28300 |
|
Extra EMI/EMC charges: 1,80,000 |
22.0(Construction) |
- |
28300 |
|
Extra EMI/EMC charges: 1,80,000 |
21.0(Mechanical Strength) |
- |
28300 |
|
Extra EMI/EMC charges: 1,80,000 |
20.0(Stability and mechanical hazards) |
- |
28300 |
|
Extra EMI/EMC charges: 1,80,000 |
19.0(Abnormal Operation) |
- |
28300 |
|
Extra EMI/EMC charges: 1,80,000 |
17.0(Overload Protection of transformer and associated circuit) |
- |
28300 |
|
Extra EMI/EMC charges: 1,80,000 |
16.0(Leakage current and Electric strength (After Humidity (Environmental) Treatment)) |
- |
28300 |
|
Extra EMI/EMC charges: 1,80,000 |
15.0(Moisture resistance) |
- |
28300 |
|
Extra EMI/EMC charges: 1,80,000 |
14.0(Transient Overvoltage) |
- |
28300 |
|
Extra EMI/EMC charges: 1,80,000 |
13.0(Leakage Current and electric strength at operating temperature) |
- |
28300 |
|
Extra EMI/EMC charges: 1,80,000 |
11.0(Heating) |
- |
28300 |
|
Extra EMI/EMC charges: 1,80,000 |
10.0(Input and Current) |
- |
28300 |
|
Extra EMI/EMC charges: 1,80,000 |
8.0(Protection against access to live parts) |
- |
28300 |
|
Extra EMI/EMC charges: 1,80,000 |
7.0(Classification) |
- |
28300 |
|
Extra EMI/EMC charges: 1,80,000 |
6.0(Marking and Instructions) |
- |
28300 |
|
Extra EMI/EMC charges: 1,80,000 |
19.11.4.1(Electrostatic discharges) |
- |
208300 |
|
- |
19.11.4.2(Radiated fields) |
- |
208300 |
|
- |
19.11.4.3(Fast transient bursts) |
- |
208300 |
|
- |
19.11.4.4(Surge immunity test) |
- |
208300 |
|
- |
19.11.4.5(Immunity to conducted discharges) |
- |
208300 |
|
- |
19.11.4.6(Class 3 Voltage dips and interruptions) |
- |
208300 |
|
- |
19.11.4.7(Harmonics) |
- |
208300 |
|
- |
4(GENERAL REQUIREMENT) |
- |
28300 |
|
Extra EMI/EMC charges: 1,80,000 |
5(GENERAL CONDITIONS FOR THE TESTS) |
- |
28300 |
|
Extra EMI/EMC charges: 1,80,000 |
|
08 May, 2028 |
- Included w.e.f.19.06.2025 |
14 |
HT Product Services Private Limited
| IS 302 : Part 2 : Sec 202 (1992) |
Safety of household and similar electrical appliances: Part 2 particular requirements: Sec 202 electric stoves |
- |
40000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
6(Classification- IS 302-1 ) |
- |
1000 |
|
- |
6(Classification- IS 302-1) |
- |
1000 |
|
- |
7.1(Marking- IS 302-1) |
- |
1000 |
|
- |
7.1(Marking- IS 302-1) |
- |
1000 |
|
- |
7.1(Marking- IS 302-1) |
- |
1000 |
|
- |
7.1(Marking- IS 302-1) |
- |
1000 |
|
- |
7.1(Marking- IS 302-1) |
- |
1000 |
|
- |
7.1(Marking- IS 302-1) |
- |
1000 |
|
- |
7.1(Marking- IS 302-1) |
- |
1000 |
|
- |
7.1(Marking- IS 302-1) |
- |
1000 |
|
- |
7.1(Marking- IS 302-1) |
- |
1000 |
|
- |
7.3(Marking- IS 302-1) |
- |
1000 |
|
- |
7.4(Marking- IS 302-1) |
- |
1000 |
|
- |
7.6(Marking- IS 302-1) |
- |
1000 |
|
- |
7.11(Marking- IS 302-1) |
- |
1000 |
|
- |
7.12(Marking- IS 302-1) |
- |
1000 |
|
- |
7.13(Marking- IS 302-1) |
- |
1000 |
|
- |
7.14(Marking- IS 302-1) |
- |
1000 |
|
- |
7.15(Marking- IS 302-1) |
- |
1000 |
|
- |
7.101(Marking) |
- |
1000 |
|
- |
8( Protection Against Electric Shock, IS 302-1) |
- |
1000 |
|
- |
10(Power Input and Current, IS 302-1) |
- |
1000 |
|
- |
11(Heating, IS 302-1) |
- |
1000 |
|
- |
11(Heating, IS 302-1) |
- |
1000 |
|
- |
11(Heating, IS 302-1) |
- |
1000 |
|
- |
11(Heating, IS 302-1) |
- |
1000 |
|
- |
11(Heating, IS 302-1) |
- |
1000 |
|
- |
11(Heating, IS 302-1) |
- |
1000 |
|
- |
11(Heating, IS 302-1) |
- |
1000 |
|
- |
12(Operation under overload conditions of appliances with heating elements, IS 302-2-202: 1992) |
- |
1000 |
|
- |
13(Electrical Insulation and Leakage Current at Operating Temperature: Leakage current, IS 302-1) |
- |
1000 |
|
- |
13(Electrical Insulation and Leakage Current at Operating Temperature: High Voltage, IS 302-1) |
- |
1000 |
|
- |
15.1(Moisture Resistance, IS 302-1) |
- |
1000 |
|
- |
15.3(Moisture Resistance, IS 302-1) |
- |
1000 |
|
- |
16(Electrical Insulation and Leakage Current at Operating Temperature: Leakage current, IS 302-1) |
- |
1000 |
|
- |
16(Electrical Insulation and Leakage Current at Operating Temperature: High Voltage, IS 302-1) |
- |
1000 |
|
- |
19.2(Abnormal Operation, IS 302-1) |
- |
1000 |
|
- |
19.2(Abnormal Operation, IS 302-1) |
- |
1000 |
|
- |
19.3(Abnormal Operation, IS 302-1) |
- |
1000 |
|
- |
19.3(Abnormal Operation, IS 302-1) |
- |
1000 |
|
- |
20.1(Stability & Mechanical Hazards, IS 302-1) |
- |
1000 |
|
- |
21.1(Mechanical Strength, IS 302-1 & IS 302-2-202) |
- |
1000 |
|
- |
22(Construction, IS 302-1) |
- |
1000 |
|
- |
22.101(Construction) |
- |
1000 |
|
- |
22.102(Construction) |
- |
1000 |
|
- |
22.103(Construction) |
- |
1000 |
|
- |
22.104(Construction) |
- |
1000 |
|
- |
22.105(Construction) |
- |
1000 |
|
- |
22.105.1(Construction) |
- |
1000 |
|
- |
22.105.2(Construction) |
- |
1000 |
|
- |
22.106(Construction) |
- |
1000 |
|
- |
11.107.1(Construction) |
- |
1000 |
|
- |
23.1(Internal Wiring, IS 302-1) |
- |
1000 |
|
- |
23.2(Internal Wiring, IS 302-1) |
- |
1000 |
|
- |
23.8(Internal Wiring, IS 302-1) |
- |
1000 |
|
- |
23.9(Internal Wiring, IS 302-1) |
- |
1000 |
|
- |
23.10(Internal Wiring, IS 302-1) |
- |
1000 |
|
- |
24.1(Components, IS 302-1) |
- |
1000 |
|
- |
24.2(Components, IS 302-1) |
- |
1000 |
|
- |
24.101(Components) |
- |
1000 |
|
- |
25.1(Supply Connection and External Flexible Cords, IS 302-1) |
- |
1000 |
|
- |
25.4(Supply Connection and External Flexible Cords) |
- |
1000 |
|
- |
25.5(Supply Connection and External Flexible Cords, IS 302-1) |
- |
1000 |
|
- |
25.6(Supply Connection and External Flexible Cords, IS 302-1) |
- |
1000 |
|
- |
25.8(Supply Connection and External Flexible Cords, IS 302-1) |
- |
1000 |
|
- |
26.9(Supply Connection and External Flexible Cords, IS 302-1) |
- |
1000 |
|
- |
25.1(Supply Connection and External Flexible Cords, IS 302-1) |
- |
1000 |
|
- |
25.11(Supply Connection and External Flexible Cords, IS 302-1) |
- |
1000 |
|
- |
25.12(Supply Connection and External Flexible Cords, IS 302-1) |
- |
1000 |
|
- |
25.15(Supply Connection and External Flexible Cords, IS 302-1) |
- |
1000 |
|
- |
25.16(Supply Connection and External Flexible Cords, IS 302-1) |
- |
1000 |
|
- |
25.17(Supply Connection and External Flexible Cords, IS 302-1) |
- |
1000 |
|
- |
25.18(Supply Connection and External Flexible Cords, IS 302-1) |
- |
1000 |
|
- |
25.19(Supply Connection and External Flexible Cords, IS 302-1) |
- |
1000 |
|
- |
25.2(Supply Connection and External Flexible Cords, IS 302-1) |
- |
1000 |
|
- |
25.21(Supply Connection and External Flexible Cords, IS 302-1) |
- |
1000 |
|
- |
25.22(Supply Connection and External Flexible Cords, IS 302-1) |
- |
1000 |
|
- |
26(Terminals for External Conductors, IS 302-1) |
- |
1000 |
|
- |
27.1(Provision for Earthing, IS 302-1) |
- |
1000 |
|
- |
27.2(Provision for Earthing, IS 302-1) |
- |
1000 |
|
- |
27.3(Provision for Earthing, IS 302-1) |
- |
1000 |
|
- |
27.4(Provision for Earthing, IS 302-1) |
- |
1000 |
|
- |
27.5(Provision for Earthing, IS 302-1) |
- |
1000 |
|
- |
28(Screws & Connections, IS 302-1) |
- |
1000 |
|
- |
29.1(Clearances, Creepage distances and Solid Insulation, IS 302-1) |
- |
1000 |
|
- |
29.2(Clearances, Creepage distances and Solid Insulation, IS 302-1) |
- |
1000 |
|
- |
30.1(Resistance to Heat, Fire & Tracking, IS 302-1) |
- |
1000 |
|
- |
30.2(Resistance to Heat, Fire & Tracking, IS 302-1) |
- |
1000 |
|
- |
31(Resistance of Rusting, IS 302-1) |
- |
1000 |
|
- |
22.107(Construction) |
- |
1000 |
|
- |
6(Classification- IS 302-1 ) |
- |
1000 |
|
- |
6(Classification- IS 302-1) |
- |
1000 |
|
- |
7.1(Marking- IS 302-1) |
- |
1000 |
|
- |
7.1(Marking- IS 302-1) |
- |
1000 |
|
- |
7.1(Marking- IS 302-1) |
- |
1000 |
|
- |
7.1(Marking- IS 302-1) |
- |
1000 |
|
- |
7.1(Marking- IS 302-1) |
- |
1000 |
|
- |
7.1(Marking- IS 302-1) |
- |
1000 |
|
- |
7.1(Marking- IS 302-1) |
- |
1000 |
|
- |
7.1(Marking- IS 302-1) |
- |
1000 |
|
- |
7.1(Marking- IS 302-1) |
- |
1000 |
|
- |
7.3(Marking- IS 302-1) |
- |
1000 |
|
- |
7.4(Marking- IS 302-1) |
- |
1000 |
|
- |
7.6(Marking- IS 302-1) |
- |
1000 |
|
- |
7.11(Marking- IS 302-1) |
- |
1000 |
|
- |
7.12(Marking- IS 302-1) |
- |
1000 |
|
- |
7.13(Marking- IS 302-1) |
- |
1000 |
|
- |
7.14(Marking- IS 302-1) |
- |
1000 |
|
- |
7.15(Marking- IS 302-1) |
- |
1000 |
|
- |
7.101(Marking) |
- |
1000 |
|
- |
8( Protection Against Electric Shock, IS 302-1) |
- |
1000 |
|
- |
10(Power Input and Current, IS 302-1) |
- |
1000 |
|
- |
11(Heating, IS 302-1) |
- |
1000 |
|
- |
11(Heating, IS 302-1) |
- |
1000 |
|
- |
11(Heating, IS 302-1) |
- |
1000 |
|
- |
11(Heating, IS 302-1) |
- |
1000 |
|
- |
11(Heating, IS 302-1) |
- |
1000 |
|
- |
11(Heating, IS 302-1) |
- |
1000 |
|
- |
11(Heating, IS 302-1) |
- |
1000 |
|
- |
12(Operation under overload conditions of appliances with heating elements, IS 302-2-202: 1992) |
- |
1000 |
|
- |
13(Electrical Insulation and Leakage Current at Operating Temperature: Leakage current, IS 302-1) |
- |
1000 |
|
- |
13(Electrical Insulation and Leakage Current at Operating Temperature: High Voltage, IS 302-1) |
- |
1000 |
|
- |
15.1(Moisture Resistance, IS 302-1) |
- |
1000 |
|
- |
15.3(Moisture Resistance, IS 302-1) |
- |
1000 |
|
- |
16(Electrical Insulation and Leakage Current at Operating Temperature: Leakage current, IS 302-1) |
- |
1000 |
|
- |
16(Electrical Insulation and Leakage Current at Operating Temperature: High Voltage, IS 302-1) |
- |
1000 |
|
- |
19.2(Abnormal Operation, IS 302-1) |
- |
1000 |
|
- |
19.2(Abnormal Operation, IS 302-1) |
- |
1000 |
|
- |
19.3(Abnormal Operation, IS 302-1) |
- |
1000 |
|
- |
19.3(Abnormal Operation, IS 302-1) |
- |
1000 |
|
- |
20.1(Stability & Mechanical Hazards, IS 302-1) |
- |
1000 |
|
- |
21.1(Mechanical Strength, IS 302-1 & IS 302-2-202) |
- |
1000 |
|
- |
22(Construction, IS 302-1) |
- |
1000 |
|
- |
22.101(Construction) |
- |
1000 |
|
- |
22.102(Construction) |
- |
1000 |
|
- |
22.103(Construction) |
- |
1000 |
|
- |
22.104(Construction) |
- |
1000 |
|
- |
22.105(Construction) |
- |
1000 |
|
- |
22.105.1(Construction) |
- |
1000 |
|
- |
22.105.2(Construction) |
- |
1000 |
|
- |
22.106(Construction) |
- |
1000 |
|
- |
11.107.1(Construction) |
- |
1000 |
|
- |
23.1(Internal Wiring, IS 302-1) |
- |
1000 |
|
- |
23.2(Internal Wiring, IS 302-1) |
- |
1000 |
|
- |
23.8(Internal Wiring, IS 302-1) |
- |
1000 |
|
- |
23.9(Internal Wiring, IS 302-1) |
- |
1000 |
|
- |
23.10(Internal Wiring, IS 302-1) |
- |
1000 |
|
- |
24.1(Components, IS 302-1) |
- |
1000 |
|
- |
24.2(Components, IS 302-1) |
- |
1000 |
|
- |
24.101(Components) |
- |
1000 |
|
- |
25.1(Supply Connection and External Flexible Cords, IS 302-1) |
- |
1000 |
|
- |
25.4(Supply Connection and External Flexible Cords) |
- |
1000 |
|
- |
25.5(Supply Connection and External Flexible Cords, IS 302-1) |
- |
1000 |
|
- |
25.6(Supply Connection and External Flexible Cords, IS 302-1) |
- |
1000 |
|
- |
25.8(Supply Connection and External Flexible Cords, IS 302-1) |
- |
1000 |
|
- |
26.9(Supply Connection and External Flexible Cords, IS 302-1) |
- |
1000 |
|
- |
25.1(Supply Connection and External Flexible Cords, IS 302-1) |
- |
1000 |
|
- |
25.11(Supply Connection and External Flexible Cords, IS 302-1) |
- |
1000 |
|
- |
25.12(Supply Connection and External Flexible Cords, IS 302-1) |
- |
1000 |
|
- |
25.15(Supply Connection and External Flexible Cords, IS 302-1) |
- |
1000 |
|
- |
25.16(Supply Connection and External Flexible Cords, IS 302-1) |
- |
1000 |
|
- |
25.17(Supply Connection and External Flexible Cords, IS 302-1) |
- |
1000 |
|
- |
25.18(Supply Connection and External Flexible Cords, IS 302-1) |
- |
1000 |
|
- |
25.19(Supply Connection and External Flexible Cords, IS 302-1) |
- |
1000 |
|
- |
25.2(Supply Connection and External Flexible Cords, IS 302-1) |
- |
1000 |
|
- |
25.21(Supply Connection and External Flexible Cords, IS 302-1) |
- |
1000 |
|
- |
25.22(Supply Connection and External Flexible Cords, IS 302-1) |
- |
1000 |
|
- |
26(Terminals for External Conductors, IS 302-1) |
- |
1000 |
|
- |
27.1(Provision for Earthing, IS 302-1) |
- |
1000 |
|
- |
27.2(Provision for Earthing, IS 302-1) |
- |
1000 |
|
- |
27.3(Provision for Earthing, IS 302-1) |
- |
1000 |
|
- |
27.4(Provision for Earthing, IS 302-1) |
- |
1000 |
|
- |
27.5(Provision for Earthing, IS 302-1) |
- |
1000 |
|
- |
28(Screws & Connections, IS 302-1) |
- |
1000 |
|
- |
29.1(Clearances, Creepage distances and Solid Insulation, IS 302-1) |
- |
1000 |
|
- |
29.2(Clearances, Creepage distances and Solid Insulation, IS 302-1) |
- |
1000 |
|
- |
30.1(Resistance to Heat, Fire & Tracking, IS 302-1) |
- |
1000 |
|
- |
30.2(Resistance to Heat, Fire & Tracking, IS 302-1) |
- |
1000 |
|
- |
31(Resistance of Rusting, IS 302-1) |
- |
1000 |
|
- |
22.107(Construction) |
- |
1000 |
|
- |
|
03 Dec, 2026 |
- Included w.e.f 09.06.2025 Exclusion: Cl 19.11.4.1-19.11.4.7 (EMI/EMC) |
15 |
ALPHA TEST HOUSE PVT LTD
| IS 302 : Part 2 : Sec 25 (2014) |
Safety of household and similar electrical appliances: Part 2 Particular requirements: Section 25 Microwave ovens |
- |
225000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
6.0(Classification) |
- |
45000 |
|
Extra EMI/EMC charges: 1,80,000 |
7(Marking and instructions) |
- |
45000 |
|
Extra EMI/EMC charges: 1,80,000 |
8(Protection against live parts) |
- |
45000 |
|
Extra EMI/EMC charges: 1,80,000 |
10(POWER INPUT AND CURRENT) |
- |
45000 |
|
Extra EMI/EMC charges: 1,80,000 |
11(HEATING) |
- |
45000 |
|
Extra EMI/EMC charges: 1,80,000 |
13(LEAKAGE CURRENT AND ELECTRIC STRENGTH AT OPERATING TEMPERATURE) |
- |
45000 |
|
Extra EMI/EMC charges: 1,80,000 |
14(IMPULSE VOLTAGE TEST) |
- |
45000 |
|
Extra EMI/EMC charges: 1,80,000 |
15(HUMIDITY TREATMENT TEST) |
- |
45000 |
|
Extra EMI/EMC charges: 1,80,000 |
16(LEAKAGE CURRENT AND ELECTRIC STRENGTH) |
- |
45000 |
|
Extra EMI/EMC charges: 1,80,000 |
17(OVERLOAD PROTECTION OF TRANSFORMERS AND ASSOCIATED CIRCUITS) |
- |
45000 |
|
Extra EMI/EMC charges: 1,80,000 |
19(ABNORMAL OPERATION) |
- |
45000 |
|
Extra EMI/EMC charges: 1,80,000 |
20(STABILITY AND MECHANICAL HAZARDS) |
- |
45000 |
|
Extra EMI/EMC charges: 1,80,000 |
21(MECHANICAL STRENGTH) |
- |
45000 |
|
Extra EMI/EMC charges: 1,80,000 |
22(CONSTRUCTION) |
- |
45000 |
|
Extra EMI/EMC charges: 1,80,000 |
23(INTERNAL WIRING) |
- |
45000 |
|
Extra EMI/EMC charges: 1,80,000 |
24(COMPONENTS) |
- |
45000 |
|
Extra EMI/EMC charges: 1,80,000 |
25(SUPPLY CONNECTION AND EXTERNAL FLEXIBLE CORDS) |
- |
45000 |
|
Extra EMI/EMC charges: 1,80,000 |
26(TERMINALS FOR EXTERNAL CONDUCTORS) |
- |
45000 |
|
Extra EMI/EMC charges: 1,80,000 |
27(PROVISION FOR EARTHING) |
- |
45000 |
|
Extra EMI/EMC charges: 1,80,000 |
28(SCREWS AND CONNECTIONS) |
- |
45000 |
|
Extra EMI/EMC charges: 1,80,000 |
29(CLEARANCES, CREEPAGE DISTANCES AND SOLID INSULATION) |
- |
45000 |
|
Extra EMI/EMC charges: 1,80,000 |
30(RESISTANCE TO HEAT AND FIRE) |
- |
45000 |
|
Extra EMI/EMC charges: 1,80,000 |
31(RESISTANCE TO RUSTING) |
- |
45000 |
|
Extra EMI/EMC charges: 1,80,000 |
32(RADIATION, TOXICITY AND SIMILAR HAZARDS) |
- |
45000 |
|
Extra EMI/EMC charges: 1,80,000 |
Cl-19.11.4.1(Electrostatic discharge) |
- |
180000 |
|
- |
Cl-19.11.4.2(Radiated Fields) |
- |
180000 |
|
- |
Cl-19.11.4.5(Immunity to conducted discharge) |
- |
180000 |
|
- |
Cl-19.11.4.3(Fast transient bursts) |
- |
180000 |
|
- |
Cl-19.11.4.4(Surge Immunity test) |
- |
180000 |
|
- |
Cl-19.11.4.6(Voltage dips and interruptions) |
- |
180000 |
|
- |
Cl-19.11.4.7(Harmonics) |
- |
180000 |
|
- |
18(ENDURANCE) |
- |
45000 |
|
Extra EMI/EMC charges: 1,80,000 |
9(STARTING OF MOTOR-OPERATED APPLIANCES) |
- |
0 |
|
- |
22.32(Oxygen bomb for rubber material) |
- |
45000 |
|
Extra EMI/EMC charges: 1,80,000 |
22.46(Software) |
- |
45000 |
|
Extra EMI/EMC charges: 1,80,000 |
|
08 May, 2028 |
- Included w.e.f.19.06.2025 |
16 |
Electrical Research and Development Association, gujarat
| IS 302 : Part 2 : Sec 80 (2017) |
Household and similar electrical appliances - Safety: Part 2 - 80 particular requirements for fans (First Revision) |
Ceiling fan, Duct fan, Partition fan, pedestal fan, Table fan |
24340 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
6.0(Marking and Instructions) |
- |
500 |
|
- |
7.0(Classification) |
- |
0 |
|
- |
8.0(Protection against access to live parts) |
- |
500 |
|
- |
10.0(Input and Current) |
- |
500 |
|
- |
11.0(Heating) |
- |
850 |
|
- |
13.0(Leakage Current and electric strength at operating temperature) |
- |
500 |
|
- |
14.0(Transient Overvoltage) |
- |
6500 |
|
- |
15.0(Moisture resistance) |
- |
2850 |
|
- |
16.0(Leakage current and Electric strength (After Humidity (Environmental) Treatment)) |
- |
500 |
|
- |
17.0(Overload Protection of transformer and associated circuit) |
- |
500 |
|
- |
19.0(Abnormal Operation) |
- |
650 |
|
- |
20.0(Stability and mechanical hazards) |
- |
500 |
|
- |
21.0(Mechanical Strength) |
- |
1100 |
|
- |
22.0(Construction) |
- |
550 |
|
- |
23.0(Internal Wiring) |
- |
500 |
|
- |
24.0(Components) |
- |
840 |
|
- |
25.0(Supply Connection and External Flexible Cords) |
- |
1150 |
|
- |
26.0(Terminals for external conductors) |
- |
500 |
|
- |
27.0(Provision For Earthing) |
- |
500 |
|
- |
28.0(Screws and Connections) |
- |
500 |
|
- |
29.0(Creepage Distances and Clearances) |
- |
500 |
|
- |
30.0(Resistance To Heat and Fire) |
- |
2850 |
|
- |
31.0(Resistance To Rusting) |
- |
500 |
|
- |
32.0(Radiation, Toxicity and Similar Hazards) |
- |
500 |
|
- |
4(GENERAL REQUIREMENT) |
- |
0 |
|
- |
5(GENERAL CONDITIONS FOR THE TESTS) |
- |
0 |
|
- |
19.11.4.1(Electrostatic discharges) |
- |
8500 |
|
If this test is applicable than additional test charges of Rs. 8500/- is applied over the total test charge of Rs. 24340/- |
19.11.4.2(Radiated fields) |
- |
25000 |
|
If this test is applicable than additional test charges of Rs. 25000/- is applied over the total test charge of Rs. 24340/- |
19.11.4.3(Fast transient bursts) |
- |
8500 |
|
If this test is applicable than additional test charges of Rs. 8500/- is applied over the total test charge of Rs. 24340/- |
19.11.4.4(Surge immunity test) |
- |
16000 |
|
If this test is applicable than additional test charges of Rs. 16000/- is applied over the total test charge of Rs. 24340/- |
19.11.4.5(Immunity to conducted discharges) |
- |
9500 |
|
If this test is applicable than additional test charges of Rs. 9500/- is applied over the total test charge of Rs. 24340/- |
19.11.4.6(Class 3 Voltage dips and interruptions) |
- |
15800 |
|
If this test is applicable than additional test charges of Rs. 15800/- is applied over the total test charge of Rs. 24340/- |
4(GENERAL REQUIREMENT) |
- |
0 |
|
- |
5(GENERAL CONDITIONS FOR THE TESTS) |
- |
0 |
|
- |
19.11.4.1(Electrostatic discharges) |
- |
8500 |
|
If this test is applicable than additional test charges of Rs. 8500/- is applied over the total test charge of Rs. 24340/- |
19.11.4.2(Radiated fields) |
- |
25000 |
|
If this test is applicable than additional test charges of Rs. 25000/- is applied over the total test charge of Rs. 24340/- |
19.11.4.3(Fast transient bursts) |
- |
8500 |
|
If this test is applicable than additional test charges of Rs. 8500/- is applied over the total test charge of Rs. 24340/- |
19.11.4.4(Surge immunity test) |
- |
16000 |
|
If this test is applicable than additional test charges of Rs. 16000/- is applied over the total test charge of Rs. 24340/- |
19.11.4.5(Immunity to conducted discharges) |
- |
9500 |
|
If this test is applicable than additional test charges of Rs. 9500/- is applied over the total test charge of Rs. 24340/- |
19.11.4.6(Class 3 Voltage dips and interruptions) |
- |
15800 |
|
If this test is applicable than additional test charges of Rs. 15800/- is applied over the total test charge of Rs. 24340/- |
4(GENERAL REQUIREMENT) |
- |
0 |
|
- |
5(GENERAL CONDITIONS FOR THE TESTS) |
- |
0 |
|
- |
19.11.4.1(Electrostatic discharges) |
- |
8500 |
|
If this test is applicable than additional test charges of Rs. 8500/- is applied over the total test charge of Rs. 24340/- |
19.11.4.2(Radiated fields) |
- |
25000 |
|
If this test is applicable than additional test charges of Rs. 25000/- is applied over the total test charge of Rs. 24340/- |
19.11.4.3(Fast transient bursts) |
- |
8500 |
|
If this test is applicable than additional test charges of Rs. 8500/- is applied over the total test charge of Rs. 24340/- |
19.11.4.4(Surge immunity test) |
- |
16000 |
|
If this test is applicable than additional test charges of Rs. 16000/- is applied over the total test charge of Rs. 24340/- |
19.11.4.5(Immunity to conducted discharges) |
- |
9500 |
|
If this test is applicable than additional test charges of Rs. 9500/- is applied over the total test charge of Rs. 24340/- |
19.11.4.6(Class 3 Voltage dips and interruptions) |
- |
15800 |
|
If this test is applicable than additional test charges of Rs. 15800/- is applied over the total test charge of Rs. 24340/- |
|
30 Nov, 2025 |
- Included w.e.f 19.06.2025
Exclusion: Cl 19.11.4.7 (Harmonics) |
17 |
HT Product Services Private Limited
| IS 302 : Part 2 : Sec 75 (2018) |
Safety of Household and Similar Electrical Appliances Part 2 Particular Requirements Section 75 Commercial Dispensing Appliances and Vending Machines |
- |
45000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
32(Radiation, toxicity and similar hazards) |
- |
1000 |
|
- |
31(Resistance to rusting) |
- |
1000 |
|
- |
30.2.4(Resistance to heat and fire) |
- |
1000 |
|
- |
30.2(Resistance to heat and fire) |
- |
1000 |
|
- |
30.1(Resistance to heat and fire) |
- |
1000 |
|
- |
29.3(Clearances, creepage distances and solid insulation) |
- |
1000 |
|
- |
29.2(Clearances, creepage distances and solid insulation) |
- |
1000 |
|
- |
29.2(Clearances, creepage distances and solid insulation) |
- |
1000 |
|
- |
29.1, Table No.- 16, Table No.- 17 & Table No.18(Clearances, creepage distances and solid insulation) |
- |
1000 |
|
- |
29.1, Table No.- 16, Table No.- 17 & Table No.18(Clearances, creepage distances and solid insulation) |
- |
1000 |
|
- |
28.2 to 28.4(Screws and connections) |
- |
1000 |
|
- |
28.1, Table No.-14(Screws and connections) |
- |
1000 |
|
- |
27.6(Provision for earthing) |
- |
1000 |
|
- |
27.5(Provision for earthing) |
- |
1000 |
|
- |
27.1 to 27.4(Provision for earthing) |
- |
1000 |
|
- |
26.10 & 26.11(Terminals for external conductors) |
- |
1000 |
|
- |
26.9(Terminals for external conductors) |
- |
1000 |
|
- |
26.1 to 26.8(Terminals for external conductors) |
- |
1000 |
|
- |
25.16 to 25.25(Supply connection and external flexible cords) |
- |
1000 |
|
- |
25.15(Supply connection and external flexible cords) |
- |
1000 |
|
- |
25.14(Supply connection and external flexible cords) |
- |
1000 |
|
- |
25.9 to 25.13(Supply connection and external flexible cords) |
- |
1000 |
|
- |
25.8, Table No.-11(Supply connection and external flexible cords) |
- |
1000 |
|
- |
25.5 to 25.7(Supply connection and external flexible cords) |
- |
1000 |
|
- |
25.4(Supply connection and external flexible cords) |
- |
1000 |
|
- |
25.3(Supply connection and external flexible cords) |
- |
1000 |
|
- |
25.2(Supply connection and external flexible cords) |
- |
1000 |
|
- |
25.1(Supply connection and external flexible cords) |
- |
1000 |
|
- |
24.101 to 24.103(Components) |
- |
1000 |
|
- |
24.2 to 24.6(Components) |
- |
1000 |
|
- |
24.1(Components) |
- |
1000 |
|
- |
23.101 to 23.102(Internal wiring) |
- |
1000 |
|
- |
23.6 to 23.10(Internal wiring) |
- |
1000 |
|
- |
23.5(Internal wiring) |
- |
1000 |
|
- |
23.4(Internal wiring) |
- |
1000 |
|
- |
23.3(Internal wiring) |
- |
1000 |
|
- |
23.1 & 23.2(Internal wiring) |
- |
1000 |
|
- |
22.101 to 22.114(Constructions) |
- |
1000 |
|
- |
22.13 to 22.48(Constructions) |
- |
1000 |
|
- |
22.12(Constructions) |
- |
1000 |
|
- |
22.11(Constructions) |
- |
1000 |
|
- |
22.11(Constructions) |
- |
1000 |
|
- |
22.7 to 22.10(Constructions) |
- |
1000 |
|
- |
22.6(Constructions) |
- |
1000 |
|
- |
22.5(Constructions) |
- |
1000 |
|
- |
22.4(Constructions) |
- |
1000 |
|
- |
22.3(Constructions) |
- |
1000 |
|
- |
22.2(Constructions) |
- |
1000 |
|
- |
22.1(Constructions) |
- |
1000 |
|
- |
21.2(MECHANICAL STRENGTH) |
- |
1000 |
|
- |
21.1(MECHANICAL STRENGTH) |
- |
1000 |
|
- |
20.2(Stability and mechanical hazards) |
- |
1000 |
|
- |
20.1(Stability and mechanical hazards) |
- |
1000 |
|
- |
19.101 and 19.102(ABNORMAL OPERATION) |
- |
1000 |
|
- |
19.1 to 19.13, Table No. - 9(ABNORMAL OPERATION) |
- |
1000 |
|
- |
17(Overload protection of transformers and associated circuits) |
- |
1000 |
|
- |
16.3(Insulation resistance test) |
- |
1000 |
|
- |
16.3(Electric strength test) |
- |
1000 |
|
- |
16.1 & 16.2(Leakage current test) |
- |
1000 |
|
- |
15.102(Moisture resistance) |
- |
1000 |
|
- |
15.102(Moisture resistance) |
- |
1000 |
|
- |
15.101(Moisture resistance) |
- |
1000 |
|
- |
15.3(Moisture resistance) |
- |
1000 |
|
- |
15.2(Moisture resistance) |
- |
1000 |
|
- |
15.1(Moisture resistance) |
- |
1000 |
|
- |
14, Table No.- 6 & Table No.-16(Transient over voltages) |
- |
1000 |
|
- |
13.3 and Table No.- 4(Electric strength test) |
- |
1000 |
|
- |
13.1, 13.2(Leakage current test) |
- |
1000 |
|
- |
11.1 to 11.8, Table No.-3(Heating) |
- |
1000 |
|
- |
10.1 & 10.2 -Table No. 1, Table No. 2(Power Input and Current) |
- |
1000 |
|
- |
8.1.5(Protection against access to live parts) |
- |
1000 |
|
- |
8.1.4(Protection against access to live parts) |
- |
1000 |
|
- |
8.1.3(Protection against access to live parts) |
- |
1000 |
|
- |
8.1.2(Protection against access to live parts) |
- |
1000 |
|
- |
8.1, 8.1.1 & 8.2(Protection against access to live parts) |
- |
1000 |
|
- |
7.14(Legibility & Durability of Markings test) |
- |
1000 |
|
- |
7.1 to 7.13, 7.15, 7.16(Marking) |
- |
1000 |
|
- |
32(Radiation, toxicity and similar hazards) |
- |
1000 |
|
- |
31(Resistance to rusting) |
- |
1000 |
|
- |
30.2.4(Resistance to heat and fire) |
- |
1000 |
|
- |
30.2(Resistance to heat and fire) |
- |
1000 |
|
- |
30.1(Resistance to heat and fire) |
- |
1000 |
|
- |
29.3(Clearances, creepage distances and solid insulation) |
- |
1000 |
|
- |
29.2(Clearances, creepage distances and solid insulation) |
- |
1000 |
|
- |
29.2(Clearances, creepage distances and solid insulation) |
- |
1000 |
|
- |
29.1, Table No.- 16, Table No.- 17 & Table No.18(Clearances, creepage distances and solid insulation) |
- |
1000 |
|
- |
29.1, Table No.- 16, Table No.- 17 & Table No.18(Clearances, creepage distances and solid insulation) |
- |
1000 |
|
- |
28.2 to 28.4(Screws and connections) |
- |
1000 |
|
- |
28.1, Table No.-14(Screws and connections) |
- |
1000 |
|
- |
27.6(Provision for earthing) |
- |
1000 |
|
- |
27.5(Provision for earthing) |
- |
1000 |
|
- |
27.1 to 27.4(Provision for earthing) |
- |
1000 |
|
- |
26.10 & 26.11(Terminals for external conductors) |
- |
1000 |
|
- |
26.9(Terminals for external conductors) |
- |
1000 |
|
- |
26.1 to 26.8(Terminals for external conductors) |
- |
1000 |
|
- |
25.16 to 25.25(Supply connection and external flexible cords) |
- |
1000 |
|
- |
25.14(Supply connection and external flexible cords) |
- |
1000 |
|
- |
25.9 to 25.13(Supply connection and external flexible cords) |
- |
1000 |
|
- |
25.8, Table No.-11(Supply connection and external flexible cords) |
- |
1000 |
|
- |
25.5 to 25.7(Supply connection and external flexible cords) |
- |
1000 |
|
- |
25.4(Supply connection and external flexible cords) |
- |
1000 |
|
- |
25.3(Supply connection and external flexible cords) |
- |
1000 |
|
- |
25.2(Supply connection and external flexible cords) |
- |
1000 |
|
- |
25.1(Supply connection and external flexible cords) |
- |
1000 |
|
- |
24.101 to 24.103(Components) |
- |
1000 |
|
- |
24.2 to 24.6(Components) |
- |
1000 |
|
- |
24.1(Components) |
- |
1000 |
|
- |
23.101 to 23.102(Internal wiring) |
- |
1000 |
|
- |
23.6 to 23.10(Internal wiring) |
- |
1000 |
|
- |
23.5(Internal wiring) |
- |
1000 |
|
- |
23.4(Internal wiring) |
- |
1000 |
|
- |
23.3(Internal wiring) |
- |
1000 |
|
- |
23.1 & 23.2(Internal wiring) |
- |
1000 |
|
- |
22.101 to 22.114(Constructions) |
- |
1000 |
|
- |
22.13 to 22.48(Constructions) |
- |
1000 |
|
- |
22.12(Constructions) |
- |
1000 |
|
- |
22.11(Constructions) |
- |
1000 |
|
- |
22.11(Constructions) |
- |
1000 |
|
- |
22.7 to 22.10(Constructions) |
- |
1000 |
|
- |
22.6(Constructions) |
- |
1000 |
|
- |
22.5(Constructions) |
- |
1000 |
|
- |
22.4(Constructions) |
- |
1000 |
|
- |
22.3(Constructions) |
- |
1000 |
|
- |
22.2(Constructions) |
- |
1000 |
|
- |
22.1(Constructions) |
- |
1000 |
|
- |
21.2(MECHANICAL STRENGTH) |
- |
1000 |
|
- |
21.1(MECHANICAL STRENGTH) |
- |
1000 |
|
- |
20.2(Stability and mechanical hazards) |
- |
1000 |
|
- |
20.1(Stability and mechanical hazards) |
- |
1000 |
|
- |
19.101 and 19.102(ABNORMAL OPERATION) |
- |
1000 |
|
- |
19.1 to 19.13, Table No. - 9(ABNORMAL OPERATION) |
- |
1000 |
|
- |
17(Overload protection of transformers and associated circuits) |
- |
1000 |
|
- |
16.3(Insulation resistance test) |
- |
1000 |
|
- |
16.3(Electric strength test) |
- |
1000 |
|
- |
16.1 & 16.2(Leakage current test) |
- |
1000 |
|
- |
15.102(Moisture resistance) |
- |
1000 |
|
- |
15.102(Moisture resistance) |
- |
1000 |
|
- |
15.101(Moisture resistance) |
- |
1000 |
|
- |
15.3(Moisture resistance) |
- |
1000 |
|
- |
15.2(Moisture resistance) |
- |
1000 |
|
- |
15.1(Moisture resistance) |
- |
1000 |
|
- |
14, Table No.- 6 & Table No.-16(Transient over voltages) |
- |
1000 |
|
- |
13.3 and Table No.- 4(Electric strength test) |
- |
1000 |
|
- |
13.1, 13.2(Leakage current test) |
- |
1000 |
|
- |
11.1 to 11.8, Table No.-3(Heating) |
- |
1000 |
|
- |
10.1 & 10.2 -Table No. 1, Table No. 2(Power Input and Current) |
- |
1000 |
|
- |
8.1.5(Protection against access to live parts) |
- |
1000 |
|
- |
8.1.4(Protection against access to live parts) |
- |
1000 |
|
- |
8.1.3(Protection against access to live parts) |
- |
1000 |
|
- |
8.1.2(Protection against access to live parts) |
- |
1000 |
|
- |
8.1, 8.1.1 & 8.2(Protection against access to live parts) |
- |
1000 |
|
- |
7.14(Legibility & Durability of Markings test) |
- |
1000 |
|
- |
7.1 to 7.13, 7.15, 7.16(Marking) |
- |
1000 |
|
- |
25.15(Supply connection and external flexible cords) |
- |
1000 |
|
- |
|
03 Dec, 2026 |
- Included w.e.f 09.06.2025 Exclusion: Cl 19.11.4.1-19.11.4.7 (EMI/EMC) |
18 |
ALPHA TEST HOUSE PVT LTD
| IS 302 : Part 1 (2008) |
Safety of household and similar electrical appliances: Part 1 general requirements (Sixth Revision) |
- |
230000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
7(Marking and instructions) |
- |
50000 |
|
(Extra EMI/EMC charges: 1,80,000/-) |
8.1.1(Protection against live parts in all positions) |
- |
50000 |
|
- |
8.1.2(Protection against live parts in openings) |
- |
50000 |
|
- |
8.1.3(Protection against live parts in visible glowing heating elements) |
- |
50000 |
|
- |
8.1.4(Protection against live parts against protective impedance) |
- |
50000 |
|
- |
10.1(Power input) |
- |
50000 |
|
- |
10.2(Current input) |
- |
50000 |
|
- |
11.1(General) |
- |
50000 |
|
- |
11.2(General) |
- |
50000 |
|
- |
11.3(Heating) |
- |
50000 |
|
- |
13.1(General) |
- |
50000 |
|
- |
13.2(Leakage current at operating temperature) |
- |
50000 |
|
- |
13.3(Electric Strength at operating temperature) |
- |
50000 |
|
- |
14(Transient Over Voltages) |
- |
50000 |
|
- |
15.0(General) |
- |
50000 |
|
- |
15.1(Ingress Protection test other than IPX0 (IP test)) |
- |
50000 |
|
- |
15.2(Spillage Test) |
- |
50000 |
|
- |
15.3(Humidity Test) |
- |
50000 |
|
- |
16.0(General) |
- |
50000 |
|
- |
16.1(General) |
- |
50000 |
|
- |
16.2(Leakage Current (after Clause 15)) |
- |
50000 |
|
- |
16.3(Electric Strength (after clause 15 and 16.2)) |
- |
50000 |
|
- |
17(Over Load Protection of Transformers and associated circuits) |
- |
50000 |
|
- |
19(Abnormal Operation) |
- |
230000 |
|
(Extra EMI/EMC charges: 1,80,000/-) |
20(Stability test) |
- |
50000 |
|
- |
21(Mechanical Strength Test) |
- |
50000 |
|
- |
22(Construction verification related test) |
- |
50000 |
|
- |
23(General) |
- |
50000 |
|
- |
24(Components) |
- |
50000 |
|
- |
25(Supply connection and external flexible cords) |
- |
50000 |
|
- |
26(Terminals for external conductors) |
- |
50000 |
|
- |
27(Provision for earthing) |
- |
50000 |
|
- |
28(Screw test and connections) |
- |
50000 |
|
- |
29(clearance, creepage distances and solid insulation) |
- |
50000 |
|
- |
30.1(Ball pressure test) |
- |
50000 |
|
- |
30.2(Glow Wire Test) |
- |
50000 |
|
- |
30.2(Needle Flame Test) |
- |
50000 |
|
- |
4(General requirement) |
- |
50000 |
|
- |
16(Leakage current and electric strength) |
- |
50000 |
|
- |
17(Overload protection of transformers and associated circuits) |
- |
50000 |
|
- |
18(Endurance) |
- |
50000 |
|
- |
8.1.5(Live parts of built-in appliances) |
- |
50000 |
|
- |
11.4(Heating appliances) |
- |
50000 |
|
- |
11.5(Motor-operated appliances) |
- |
50000 |
|
- |
11.6(Combined appliances) |
- |
50000 |
|
- |
11.7(Duration corresponding) |
- |
50000 |
|
- |
11.8(Temperature rise) |
- |
50000 |
|
- |
4(General Requirement) |
- |
50000 |
|
- |
5(General conditions for tests) |
- |
50000 |
|
- |
6(Classifications) |
- |
50000 |
|
- |
9(Starting of motor operation test requirements and tests) |
- |
50000 |
|
- |
31(Resistance to Rusting) |
- |
50000 |
|
- |
32(Radiation Toxicity and Similar Hazards) |
- |
50000 |
|
- |
19.11.4.1(Electrostatic discharges) |
- |
50000 |
|
- |
19.11.4.2(Radiated fields) |
- |
50000 |
|
- |
19.11.4.3(Fast transient bursts) |
- |
50000 |
|
- |
19.11.4.4(Surge immunity test) |
- |
50000 |
|
- |
19.11.4.5(Immunity to conducted discharges) |
- |
50000 |
|
- |
19.11.4.6(Class 3 Voltage dips and interruptions) |
- |
50000 |
|
- |
19.11.4.7(Harmonics) |
- |
50000 |
|
- |
18(Endurance Test requirements and tests) |
- |
50000 |
|
(Extra EMI/EMC charges: 1,80,000/-) |
|
08 May, 2028 |
- Included w.e.f.19.06.2025 |
19 |
HT Product Services Private Limited
| IS 302 : Part 2 : SEC 31 (2009) |
Safety of household and similar electrical appliances: Part 2 particular requirements: Sec 31 range hoods |
- |
40000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Clause No - 5(GENERAL CONDITIONS FOR THE TESTS) |
- |
1000 |
|
- |
Clause No - 5.18(linear and angular dimension) |
- |
1000 |
|
- |
Clause No - 6.2(harmfull ingress of water) |
- |
1000 |
|
- |
Clause No - 8.1.1("PROTECTION AGAINST ACCESS TO LIVE
PART- test probe B") |
- |
1000 |
|
- |
Clause No - 8.1.2("PROTECTION AGAINST ACCESS TO LIVE
PART - test probe 13") |
- |
1000 |
|
- |
Clause No - 8.2(Addition) |
- |
1000 |
|
- |
Clause No - 10.1, Table No. -1(power input deviation) |
- |
3000 |
|
- |
Clause No - 13.3("LEAKAGE CURRENT AND ELECTRIC
STRENGTH AT OPERATING TEMPERATURE") |
- |
1000 |
|
- |
Clause No - 13.3,Table No.- 4(voltage for electrical strength) |
- |
1000 |
|
- |
Clause No - 14(Impulse test voltage) |
- |
2000 |
|
- |
Clause No - 15.1.1(MOISTURE RESISTANCE) |
- |
3000 |
|
- |
Clause No -19.7(test is repeated with the capacitor short circuited) |
- |
1000 |
|
- |
Clause No -21.1(Mechanical strength) |
- |
1000 |
|
- |
Clause No -22.1(construction) |
- |
1000 |
|
- |
Clause No -22.11(push force applied) |
- |
500 |
|
- |
Clause No -24.1.2(safety isolating transformer) |
- |
500 |
|
- |
Clause No -24.1.3(for switches) |
- |
1000 |
|
- |
Clause No -24.1.4(for automatic control) |
- |
1000 |
|
- |
Clause No -24.1.5(for innterconnection couplers) |
- |
1000 |
|
- |
Clause No -24.4(plug and socket) |
- |
1000 |
|
- |
Clause No -25.8, Table no -11(conductor resistance) |
- |
1000 |
|
- |
Clause No -25.5(dimension for pins) |
- |
1000 |
|
- |
Clause No -27.6(for circuit board) |
- |
1000 |
|
- |
Clause No -29.2(comparative tracking index) |
- |
1000 |
|
- |
Clause No -29.3.3(dry heat test) |
- |
1000 |
|
- |
Clause No -30.2.1(glow wire test) |
- |
1000 |
|
- |
Clause No -30.101("incorporate combustible
material") |
- |
1000 |
|
- |
15(MOISTURE RESISTANCE) |
- |
1000 |
|
- |
16(LEAKAGE CURRENT AND ELECTRIC STRENGTH) |
- |
1000 |
|
- |
17(OVERLOAD PROTECTION OF TRANSFORMERS AND ASSOCIATED CIRCUITS) |
- |
1000 |
|
- |
18(ENDURANCE) |
- |
500 |
|
- |
28(SCREWS AND CONNECTIONS) |
- |
500 |
|
- |
31(RESISTANCE TO RUSTING) |
- |
500 |
|
- |
32(RADIATION, TOXICITY AND SIMILAR
HAZARDS) |
- |
500 |
|
- |
11(Heating) |
- |
2000 |
|
- |
22(CONSTRUCTION) |
- |
1000 |
|
- |
24(COMPONENTS) |
- |
1000 |
|
- |
|
03 Dec, 2026 |
- Included w.e.f 09.06.2025 Exclusion: Cl 19.11.4.1-19.11.4.7 (EMI/EMC) |
20 |
HT Product Services Private Limited
| IS 302 : Part 2 : Sec 23 (2009) |
Safety of household and similar electrical appliances: Part 2 particular requirements: Sec 23 appliances for skin or hair care (First Revision) |
- |
40000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
6(Classification) |
- |
1000 |
|
- |
7(Marking/ Marking & Instructions) |
- |
1000 |
|
- |
8(Protection against Electric Shock/ Protection against Access to Live Parts) |
- |
1000 |
|
- |
9(Starting Of Motor Operated Appliances) |
- |
1000 |
|
- |
10(Power Input
& Current) |
- |
5000 |
|
- |
11(Temperature Rise/Heating) |
- |
4000 |
|
- |
13(Leakage Current and Electric Strength at Operating Temperature) |
- |
1000 |
|
- |
14(Transient Over Voltage) |
- |
1000 |
|
- |
15(Moisture Resistance) |
- |
5000 |
|
- |
16(Leakage Current and Electric Strength) |
- |
1000 |
|
- |
17(Overload Protection/ Overload Protection of Transformers & Associated Circuits) |
- |
1000 |
|
- |
18(Endurance) |
- |
1000 |
|
- |
19(Abnormal Operation) |
- |
3000 |
|
- |
20(Stability & Mechanical Hazards) |
- |
1000 |
|
- |
21(Mechanical strength) |
- |
1000 |
|
- |
22(Construction) |
- |
1000 |
|
- |
23(Internal wiring) |
- |
1000 |
|
- |
24(Component) |
- |
2000 |
|
- |
25(Supply Connection & External Flexible Cables and Cords) |
- |
1000 |
|
- |
26(Terminals For External Conductors) |
- |
1000 |
|
- |
27(Provision For Earthing) |
- |
1000 |
|
- |
28(Screws & Connection) |
- |
1000 |
|
- |
29(Clearances, Creepage Distances & Solid Insulation) |
- |
1000 |
|
- |
30(Resistance to Heat & Fire) |
- |
1000 |
|
- |
31(Resistance to Rusting) |
- |
500 |
|
- |
32(Radiation ,Toxicity and similar hazards) |
- |
500 |
|
- |
22.32(CONSTRUCTION) |
- |
1000 |
|
- |
|
03 Dec, 2026 |
- Included w.e.f 09.06.2025 Exclusion: Cl 19.11.4.1-19.11.4.7 (EMI/EMC) |
21 |
HT Product Services Private Limited
| IS 302 : Part 1 (2008) |
Safety of household and similar electrical appliances: Part 1 general requirements (Sixth Revision) |
- |
20000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
7(Marking and instructions) |
- |
500 |
|
- |
8.1.1(Protection against live parts in all positions) |
- |
500 |
|
- |
8.1.2(Protection against live parts in openings) |
- |
500 |
|
- |
8.1.3(Protection against live parts in visible glowing heating elements) |
- |
500 |
|
- |
8.1.4(Protection against live parts against protective impedance) |
- |
500 |
|
- |
9(Starting of motor operation test requirements and tests) |
- |
500 |
|
- |
10.1(Power input) |
- |
5000 |
|
- |
10.2(Current input) |
- |
5000 |
|
- |
11.1(General) |
- |
1000 |
|
- |
11.2(General) |
- |
1000 |
|
- |
11.3(Heating) |
- |
1000 |
|
- |
13.1(General) |
- |
1000 |
|
- |
13.2(Leakage current at operating temperature) |
- |
500 |
|
- |
13.3(Electric Strength at operating temperature) |
- |
500 |
|
- |
14(Transient Over Voltages) |
- |
500 |
|
- |
15.0(General) |
- |
500 |
|
- |
15.1(Ingress Protection test other than IPX0 (IP test)) |
- |
500 |
|
- |
15.2(Spillage Test) |
- |
500 |
|
- |
15.3(Humidity Test) |
- |
2000 |
|
- |
16.0(General) |
- |
500 |
|
- |
16.1(General) |
- |
500 |
|
- |
16.2(Leakage Current (after Clause 15)) |
- |
500 |
|
- |
16.3(Electric Strength (after clause 15 and 16.2)) |
- |
500 |
|
- |
17(Over Load Protection of Transformers and associated circuits) |
- |
500 |
|
- |
18(Endurance Test requirements and tests) |
- |
500 |
|
- |
19(Abnormal Operation) |
- |
500 |
|
- |
20(Stability test) |
- |
500 |
|
- |
21(Mechanical Strength Test) |
- |
500 |
|
- |
22(Construction verification related test) |
- |
500 |
|
- |
23(General) |
- |
500 |
|
- |
24(Components) |
- |
500 |
|
- |
25(Supply connection and external flexible cords) |
- |
500 |
|
- |
26(Terminals for external conductors) |
- |
500 |
|
- |
27(Provision for earthing) |
- |
500 |
|
- |
28(Screw test and connections) |
- |
500 |
|
- |
29(clearance, creepage distances and solid insulation) |
- |
500 |
|
- |
30.1(Ball pressure test) |
- |
500 |
|
- |
30.2(Glow Wire Test) |
- |
500 |
|
- |
30.2(Needle Flame Test) |
- |
500 |
|
- |
31(Resistance to Rusting) |
- |
500 |
|
- |
4(General requirement) |
- |
500 |
|
- |
16(Leakage current and electric strength) |
- |
500 |
|
- |
17(Overload protection of transformers and associated circuits) |
- |
500 |
|
- |
18(Endurance) |
- |
500 |
|
- |
8.1.5(Live parts of built-in appliances) |
- |
500 |
|
- |
11.4(Heating appliances) |
- |
500 |
|
- |
11.5(Motor-operated appliances) |
- |
500 |
|
- |
11.6(Combined appliances) |
- |
500 |
|
- |
11.7(Duration corresponding) |
- |
500 |
|
- |
11.8(Temperature rise) |
- |
500 |
|
- |
4(General Requirement) |
- |
500 |
|
- |
5(General conditions for tests) |
- |
500 |
|
- |
6(Classifications) |
- |
500 |
|
- |
|
03 Dec, 2026 |
- Included w.e.f 09.06.2025 Exclusion: Cl 19.11.4.1-19.11.4.7 (EMI/EMC), Cl 32 (Radiation, Toxicity and similar Hazard ) |
22 |
HT Product Services Private Limited
| IS 302 : Part 2 : Sec 14 (2009) |
Safety of household and similar electrical appliances: Part 2 particular requirements: Sec 14 electric kitchen machines (First Revision) |
- |
20000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
6(Classification- IS 302-1) |
- |
1000 |
|
- |
6(Classification- IS 302-1 ) |
- |
1000 |
|
- |
7.1(Marking- IS 302-1) |
- |
1000 |
|
- |
7.1(Marking- IS 302-1) |
- |
1000 |
|
- |
7.1(Marking- IS 302-1) |
- |
1000 |
|
- |
7.1(Marking- IS 302-1) |
- |
1000 |
|
- |
7.1(Marking- IS 302-1) |
- |
1000 |
|
- |
7.1(Marking- IS 302-1) |
- |
1000 |
|
- |
7.1(Marking- IS 302-1) |
- |
1000 |
|
- |
7.1(Marking- IS 302-1) |
- |
1000 |
|
- |
7.3(Marking- IS 302-1) |
- |
1000 |
|
- |
7.4(Marking- IS 302-1) |
- |
1000 |
|
- |
7.6(Marking- IS 302-1) |
- |
1000 |
|
- |
7.7(Marking- IS 302-1) |
- |
1000 |
|
- |
7.8(Marking- IS 302-1) |
- |
1000 |
|
- |
7.11(Marking- IS 302-1) |
- |
1000 |
|
- |
7.12(Marking- IS 302-1) |
- |
1000 |
|
- |
7.13(Marking- IS 302-1) |
- |
1000 |
|
- |
7.14(Marking- IS 302-1) |
- |
1000 |
|
- |
7.15(Marking- IS 302-1) |
- |
1000 |
|
- |
7.101(Marking) |
- |
1000 |
|
- |
8( Protection Against Electric Shock, IS 302-1) |
- |
1000 |
|
- |
10(Power Input and Current, IS 302-1) |
- |
5000 |
|
- |
11(Heating, IS 302-1) |
- |
5000 |
|
- |
11(Heating, IS 302-1) |
- |
5000 |
|
- |
11(Heating, IS 302-1) |
- |
5000 |
|
- |
11(Heating, IS 302-1) |
- |
5000 |
|
- |
11(Heating, IS 302-1) |
- |
5000 |
|
- |
13(Electrical Insulation and Leakage Current at Operating Temperature: Leakage current, IS 302-1) |
- |
1000 |
|
- |
13(Electrical Insulation and Leakage Current at Operating Temperature: High Voltage, IS 302-1) |
- |
1000 |
|
- |
14(Transient Over Voltages, IS 302-1) |
- |
1000 |
|
- |
15.1(Moisture Resistance, IS 302-1) |
- |
5000 |
|
- |
15.2(Moisture Resistance, IS 302-1) |
- |
5000 |
|
- |
15(Moisture Resistance, IS 302-1) |
- |
5000 |
|
- |
16(Electrical Insulation and Leakage Current at Operating Temperature: Leakage current, IS 302-1) |
- |
1000 |
|
- |
16(Electrical Insulation and Leakage Current at Operating Temperature: High Voltage, IS 302-1) |
- |
1000 |
|
- |
17(Overload protection of Transformers and Associated Circuits, IS 302-1) |
- |
2000 |
|
- |
17(Overload protection of Transformers and Associated Circuits, IS 302-1) |
- |
1000 |
|
- |
19.7(Abnormal Operation, IS 302-1) |
- |
1000 |
|
- |
19.8(Abnormal Operation, IS 302-1) |
- |
1000 |
|
- |
19.9(Abnormal Operation, IS 302-1) |
- |
1000 |
|
- |
19.1(Abnormal Operation, IS 302-1) |
- |
1000 |
|
- |
19.101(Abnormal Operation) |
- |
1000 |
|
- |
19.102(Abnormal Operation) |
- |
1000 |
|
- |
20.1(Stability & Mechanical Hazards, IS 302-1) |
- |
1000 |
|
- |
20.2(Stability & Mechanical Hazards, IS 302-1) |
- |
1000 |
|
- |
20.101(Stability & Mechanical Hazards) |
- |
1000 |
|
- |
20.102(Stability & Mechanical Hazards) |
- |
1000 |
|
- |
20.103(Stability & Mechanical Hazards) |
- |
1000 |
|
- |
20.104(Stability & Mechanical Hazards) |
- |
1000 |
|
- |
20.105(Stability & Mechanical Hazards) |
- |
1000 |
|
- |
20.106(Stability & Mechanical Hazards) |
- |
1000 |
|
- |
20.107(Stability & Mechanical Hazards) |
- |
1000 |
|
- |
20.108(Stability & Mechanical Hazards) |
- |
1000 |
|
- |
20.109(Stability & Mechanical Hazards) |
- |
1000 |
|
- |
20.110(Stability & Mechanical Hazards) |
- |
1000 |
|
- |
20.111(Stability & Mechanical Hazards) |
- |
1000 |
|
- |
20.112(Stability & Mechanical Hazards) |
- |
1000 |
|
- |
20.113(Stability & Mechanical Hazards) |
- |
1000 |
|
- |
20.114(Stability & Mechanical Hazards) |
- |
1000 |
|
- |
20.115(Stability & Mechanical Hazards) |
- |
1000 |
|
- |
20.116(Stability & Mechanical Hazards) |
- |
1000 |
|
- |
21.1(Mechanical Strength, IS 302-1) |
- |
1000 |
|
- |
21.2(Mechanical Strength, IS 302-1) |
- |
1000 |
|
- |
22(Construction, IS 302-1) |
- |
1000 |
|
- |
22.101(Construction) |
- |
1000 |
|
- |
22.102(Construction) |
- |
1000 |
|
- |
23.1(Internal Wiring, IS 302-1) |
- |
1000 |
|
- |
23.2(Internal Wiring, IS 302-1) |
- |
1000 |
|
- |
23.3(Internal Wiring, IS 302-1) |
- |
1000 |
|
- |
23.4(Internal Wiring, IS 302-1) |
- |
1000 |
|
- |
23.5(Internal Wiring, IS 302-1) |
- |
1000 |
|
- |
23.6(Internal Wiring, IS 302-1) |
- |
1000 |
|
- |
23.7(Internal Wiring, IS 302-1) |
- |
1000 |
|
- |
23.8(Internal Wiring, IS 302-1) |
- |
1000 |
|
- |
23.9(Internal Wiring, IS 302-1) |
- |
1000 |
|
- |
23.10(Internal Wiring, IS 302-1) |
- |
1000 |
|
- |
24.1(Components, IS 302-1) |
- |
1000 |
|
- |
24.2(Components, IS 302-1) |
- |
1000 |
|
- |
24.5(Components, IS 302-1) |
- |
1000 |
|
- |
24.6(Components, IS 302-1) |
- |
1000 |
|
- |
25.1(Supply Connection and External Flexible Cords, IS 302-1) |
- |
1000 |
|
- |
25.5(Supply Connection and External Flexible Cords, IS 302-1) |
- |
1000 |
|
- |
25.6(Supply Connection and External Flexible Cords, IS 302-1) |
- |
1000 |
|
- |
25.7(Supply Connection and External Flexible Cords, IS 302-1) |
- |
1000 |
|
- |
25.8(Supply Connection and External Flexible Cords, IS 302-1) |
- |
1000 |
|
- |
26.9(Supply Connection and External Flexible Cords, IS 302-1) |
- |
1000 |
|
- |
25.1(Supply Connection and External Flexible Cords, IS 302-1) |
- |
1000 |
|
- |
25.11(Supply Connection and External Flexible Cords, IS 302-1) |
- |
1000 |
|
- |
25.12(Supply Connection and External Flexible Cords, IS 302-1) |
- |
1000 |
|
- |
25.13(Supply Connection and External Flexible Cords, IS 302-1) |
- |
1000 |
|
- |
25.14(Supply Connection and External Flexible Cords, IS 302-1) |
- |
1000 |
|
- |
25.14(Supply Connection and External Flexible Cords, IS 302-1) |
- |
1000 |
|
- |
25.15(Supply Connection and External Flexible Cords, IS 302-1) |
- |
1000 |
|
- |
25.16(Supply Connection and External Flexible Cords, IS 302-1) |
- |
1000 |
|
- |
25.17(Supply Connection and External Flexible Cords, IS 302-1) |
- |
1000 |
|
- |
25.18(Supply Connection and External Flexible Cords, IS 302-1) |
- |
1000 |
|
- |
25.19(Supply Connection and External Flexible Cords, IS 302-1) |
- |
1000 |
|
- |
25.2(Supply Connection and External Flexible Cords, IS 302-1) |
- |
1000 |
|
- |
25.21(Supply Connection and External Flexible Cords, IS 302-1) |
- |
1000 |
|
- |
25.22(Supply Connection and External Flexible Cords, IS 302-1) |
- |
1000 |
|
- |
26(Terminals for External Conductors, IS 302-1) |
- |
1000 |
|
- |
27(Provision for Earthing, IS 302-1) |
- |
1000 |
|
- |
27.2(Provision for Earthing, IS 302-1) |
- |
1000 |
|
- |
27.3(Provision for Earthing, IS 302-1) |
- |
1000 |
|
- |
27.4(Provision for Earthing, IS 302-1) |
- |
1000 |
|
- |
27.5(Provision for Earthing, IS 302-1) |
- |
1000 |
|
- |
28(Screws & Connections, IS 302-1) |
- |
1000 |
|
- |
29.1(Clearances, Creepage distances and Solid Insulation, IS 302-1) |
- |
1000 |
|
- |
29.2(Clearances, Creepage distances and Solid Insulation, IS 302-1) |
- |
1000 |
|
- |
30.1(Resistance to Heat and Fire, IS 302-1) |
- |
1000 |
|
- |
30.2(Resistance to Heat and Fire, IS 302-1) |
- |
1000 |
|
- |
31(Resistance of Rusting, IS 302-1) |
- |
1000 |
|
- |
4(GENERAL REQUIREMENTS) |
- |
1000 |
|
- |
5(GENERAL CONDITIONS FOR THE TESTS) |
- |
1000 |
|
- |
27(Provision for Earthing) |
- |
1000 |
|
- |
29(Clearances, Creepage distances and Solid Insulation) |
- |
1000 |
|
- |
|
03 Dec, 2026 |
- Included w.e.f 06.06.2025
Exclusion: Cl 19.11.4.1-19.11.4.7 (EMI/EMC), Cl 32 (Radiation, Toxicity and similar Hazard IS 302-1) |
23 |
HT Product Services Private Limited
| IS 302 : Part 2 : Sec 2 (1997) |
Safety of household and similar electrical appliances: Part 2 particular requirements: Sec 2 vacuum cleaners and water suction cleaning appliances |
- |
30000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
5(Rating) |
- |
1000 |
|
- |
6(Classification) |
- |
1000 |
|
- |
7(Marking) |
- |
1000 |
|
- |
8(Protection against Access to Live Parts) |
- |
1000 |
|
- |
9(Starting Of Motor Operated Appliances) |
- |
1000 |
|
- |
10("Power Input
& Current") |
- |
3000 |
|
- |
11(Temperature Rise/ Heating) |
- |
2000 |
|
- |
12(OPERATION UNDER OVERLOAD
CONDITIONS OF APPLIANCES WITH
HEATING ELEMENTS) |
- |
1000 |
|
- |
13(LEAKAGE CURRENT AND ELECTRIC
STRENGTH AT OPERATING TEMPERATURE) |
- |
1000 |
|
- |
14(RADIO AND TELEVISION
INTERFERENCE SUPPRESSION) |
- |
500 |
|
- |
15(MOISTURE RESISTANCE) |
- |
2000 |
|
- |
16(INSULATION RESISTANCE AND
ELECTRIC STRENGTH ( AFTER HUMIDITY
TREATMENT )) |
- |
1000 |
|
- |
17(OVERLOAD PROTECTION) |
- |
1000 |
|
- |
19(ABNORMAL OPERATION) |
- |
1000 |
|
- |
20(STABILITY AND MECHANICAL
HAZARDS) |
- |
1000 |
|
- |
21(MECHANICAL STRENGTH) |
- |
1000 |
|
- |
22(Construction) |
- |
1000 |
|
- |
23(INTERNAL WIRING) |
- |
1000 |
|
- |
25(SUPPLY CONNECTION AND EXTERNAL
FLEXIBLE CABLES AND CORDS) |
- |
1000 |
|
- |
26(TERMINALS FOR EXTERNAL CONDUCTORS) |
- |
1000 |
|
- |
27(PROVISION FOR EARTHING) |
- |
1000 |
|
- |
28(SCREWS AND CONNECTIONS) |
- |
1000 |
|
- |
29(CREEPAGE DISTANCES, CLEARANCES
AND DISTANCES THROUGH INSULATION) |
- |
1000 |
|
- |
30(RESISTANCE TO HEAT, FIRE AND
TRACKING) |
- |
1000 |
|
- |
31(RESISTANCE TO RUSTING) |
- |
1000 |
|
- |
32(RADIATION HAZARDS) |
- |
500 |
|
- |
24(COMPONENTS) |
- |
1000 |
|
- |
|
03 Dec, 2026 |
- Included w.e.f 06.06.2025 Exclusion: Cl 19.11.4.1-19.11.4.7 (EMI/EMC) |
24 |
HT Product Services Private Limited
| IS 302 : Part 2 : Sec 32 (1994) |
Safety of household and similar electrical appliances: Part 2 particular requirements: Sec 32 massage appliances |
- |
50000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
(CI. 6 IS 302-2-32 : 1994(Classification ) |
- |
1000 |
|
- |
Cl. 7 302-2-32 : 1994(Marking) |
- |
1000 |
|
- |
Cl. 8 302-2-32 : 1994(Starting of motor operated appliances) |
- |
1000 |
|
- |
Cl. 9 302-2-32 : 1994(Protection Against Electric Shock) |
- |
2000 |
|
- |
Cl. 10 302-2-32 : 1994(Power Input and Current ) |
- |
4000 |
|
- |
Cl. 11 302-2-32 : 1994(Temperature Rise) |
- |
2000 |
|
- |
Cl. 13 302-2-32 : 1994(Leakage Current & Electric Strength at Operating Temperature) |
- |
2000 |
|
- |
Cl. 14 302-2-32 : 1994(Radio and television interference suppression / Transient over voltages) |
- |
1000 |
|
- |
Cl. 15 302-2-32: 1994(Moisture Resistance Test ) |
- |
5000 |
|
- |
Cl. 16 302-2-32 : 1994(Leakage Current & Electric Strength at Operating Temperature (After Humidity Treatment)) |
- |
2000 |
|
- |
Cl. 17 302-2-32 : 1994(Overload Protection of Transformers and Associated Circuit) |
- |
2000 |
|
- |
Cl. 18 302-2-32 : 1994(Endurance) |
- |
2000 |
|
- |
Cl. 19 302-2-32 : 1994(Abnormal Operation ) |
- |
3000 |
|
- |
Cl. 20 302-2-32 : 1994(Stability & Mechanical Hazards) |
- |
2000 |
|
- |
Cl. 21 302-2-32 : 1994(Mechanical strength) |
- |
2000 |
|
- |
Cl. 22 302-2-32 : 1994(Construction ) |
- |
2000 |
|
- |
Cl. 23 302-2-32 : 1994(Internal Wiring) |
- |
2000 |
|
- |
Cl. 24 302-2-32 : 1994(Components) |
- |
2000 |
|
- |
Cl. 25 302-2-32 : 1994(Supply Connection & External Flexible Cords) |
- |
2000 |
|
- |
Cl. 26 302-2-32 : 1994(Terminals for External conductors ) |
- |
2000 |
|
- |
Cl. 27 302-2-32 : 1994(Provision for Earthing ) |
- |
1000 |
|
- |
Cl. 28 302-2-32 : 1994(Screws & Connections) |
- |
1000 |
|
- |
Cl. 29 302-2-32 : 1994(Clearances, Creepage Distances & Solid insulation ) |
- |
1000 |
|
- |
Cl. 30 302-2-32 : 1994(Resistance to Heat Fire & Tracking ) |
- |
2000 |
|
- |
Cl. 31 302-2-32 : 1994(Resistance to Rusting) |
- |
2000 |
|
- |
Cl. 32 302-2-32 : 1994(Radiation Hazards) |
- |
1000 |
|
- |
|
03 Dec, 2026 |
- Included w.e.f 06.06.2025 Exclusion: Cl 19.11.4.1-19.11.4.7 (EMI/EMC) |
25 |
HT Product Services Private Limited
| IS 302 : Part 2 : Sec 8 (2024) |
Household and Similar Electrical Appliances âSafety Part 2 Particular Requirements Section 8 Shavers, Hair Clippers and Similar Appliances (First Revision) |
- |
45000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
7(Marking and instructions) |
- |
1000 |
|
- |
8(Protection against access to live parts) |
- |
2000 |
|
- |
10(Power input and current) |
- |
4000 |
|
- |
11(Heating) |
- |
3000 |
|
- |
12(Charging of metal-ion batteries) |
- |
1000 |
|
- |
13.1 &13.2(Leakage current test) |
- |
1000 |
|
- |
13.1 &13.3(Electric strength test) |
- |
1000 |
|
- |
14(Transient overvoltages) |
- |
1000 |
|
- |
15(Moisture resistance) |
- |
5000 |
|
- |
15.3(Moisture resistance) |
- |
1000 |
|
- |
16.1 &16.2(Leakage current test) |
- |
1000 |
|
- |
16.1 & 16.3(Electric strength test) |
- |
1000 |
|
- |
17(Overload protection of transformers and associated circuits) |
- |
1000 |
|
- |
19.1 to 19.13, Table No. - 9(Abnormal operation) |
- |
3000 |
|
- |
19.101(Abnormal operation) |
- |
1000 |
|
- |
20.1(Stability and mechanical hazards) |
- |
1000 |
|
- |
20.2(Stability and mechanical hazards) |
- |
1000 |
|
- |
21(Mechanical strength) |
- |
1000 |
|
- |
21.101(Mechanical strength) |
- |
1000 |
|
- |
21.102(Mechanical strength) |
- |
1000 |
|
- |
21.103(Mechanical strength) |
- |
1000 |
|
- |
22(Construction) |
- |
1000 |
|
- |
22.101(Construction) |
- |
1000 |
|
- |
22.102(Construction) |
- |
1000 |
|
- |
22.103(Construction) |
- |
1000 |
|
- |
23(Internal wiring) |
- |
1000 |
|
- |
24(Components) |
- |
1000 |
|
- |
25("Supply connection and
external flexible cords") |
- |
1000 |
|
- |
26("Terminals for external
conductors") |
- |
1000 |
|
- |
27(Provision for earthing) |
- |
1000 |
|
- |
28(Screws and connections) |
- |
1000 |
|
- |
29("Clearances, creepage
distances and solid insulation") |
- |
1000 |
|
- |
30(Resistance to heat and fire) |
- |
1000 |
|
- |
31(Resistance to rusting) |
- |
1000 |
|
- |
32("Radiation, toxicity and similar
hazards") |
- |
1000 |
|
- |
|
03 Dec, 2026 |
- Included w.e.f 06.06.2025 Exclusion: Cl 19.11.4.1-19.11.4.7 (EMI/EMC) |
26 |
HT Product Services Private Limited
| IS 302 : Part 2 : Sec 80 (2017) |
Household and similar electrical appliances - Safety: Part 2 - 80 particular requirements for fans (First Revision) |
- |
20000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
4(GENERAL REQUIREMENT) |
- |
500 |
|
- |
5(GENERAL CONDITIONS FOR THE TESTS) |
- |
500 |
|
- |
6.0(Marking and Instructions) |
- |
500 |
|
- |
7.0(Classification) |
- |
500 |
|
- |
8.0(Protection against access to live parts) |
- |
500 |
|
- |
10.0(Input and Current) |
- |
1500 |
|
- |
11.0(Heating) |
- |
2000 |
|
- |
13.0(Leakage Current and electric strength at operating temperature) |
- |
500 |
|
- |
14.0(Transient Overvoltage) |
- |
1000 |
|
- |
15.0(Moisture resistance) |
- |
3000 |
|
- |
16.0(Leakage current and Electric strength (After Humidity (Environmental) Treatment)) |
- |
500 |
|
- |
17.0(Overload Protection of transformer and associated circuit) |
- |
500 |
|
- |
19.0(Abnormal Operation) |
- |
1000 |
|
- |
20.0(Stability and mechanical hazards) |
- |
500 |
|
- |
21.0(Mechanical Strength) |
- |
500 |
|
- |
22.0(Construction) |
- |
500 |
|
- |
23.0(Internal Wiring) |
- |
500 |
|
- |
24.0(Components) |
- |
500 |
|
- |
25.0(Supply Connection and External Flexible Cords) |
- |
500 |
|
- |
26.0(Terminals for external conductors) |
- |
500 |
|
- |
27.0(Provision For Earthing) |
- |
500 |
|
- |
28.0(Screws and Connections) |
- |
500 |
|
- |
29.0(Creepage Distances and Clearances) |
- |
500 |
|
- |
30.0(Resistance To Heat and Fire) |
- |
1000 |
|
- |
31.0(Resistance To Rusting) |
- |
1000 |
|
- |
32.0(Radiation, Toxicity and Similar Hazards) |
- |
500 |
|
- |
|
03 Dec, 2026 |
- Included w.e.f 06.06.2025 Exclusion: Cl 19.11.4.1-19.11.4.7 (EMI/EMC) |
27 |
HT Product Services Private Limited
| IS 302 : Part 1 (2024) |
Household and Similar Electrical Appliances â Safety Part 1 General Requirements (Seventh Revision) |
- |
77000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
5(General conditions for the tests) |
- |
500 |
|
- |
6(Classification) |
- |
500 |
|
- |
7(Marking and instructions) |
- |
500 |
|
- |
8.1.5(Live parts of built-in appliances) |
- |
500 |
|
- |
4(General requirement) |
- |
500 |
|
- |
8.1.1(Protection against live parts in all positions) |
- |
500 |
|
- |
8.1.2(Protection against live parts in openings) |
- |
500 |
|
- |
8.1.3(Protection against live parts in visible glowing heating elements) |
- |
500 |
|
- |
8.1.4(Protection against live parts against protective impedance) |
- |
500 |
|
- |
9(Starting of motor operation test requirements and tests) |
- |
500 |
|
- |
10.1(Power input) |
- |
500 |
|
- |
10.2(Current input) |
- |
500 |
|
- |
11.2(General) |
- |
500 |
|
- |
11.4(Heating appliances) |
- |
500 |
|
- |
11.5(Motor-operated appliances) |
- |
500 |
|
- |
11.6(Combined appliances) |
- |
500 |
|
- |
11.7(Duration corresponding) |
- |
500 |
|
- |
11.8(Temperature rise) |
- |
500 |
|
- |
13(Leakage current and electric strength at operating temperature) |
- |
500 |
|
- |
13.2(Leakage current at operating temperature) |
- |
500 |
|
- |
13.3(Electric Strength at operating temperature) |
- |
500 |
|
- |
14(Transient Over Voltages) |
- |
500 |
|
- |
15.0(Moisture resistance) |
- |
500 |
|
- |
15.1(Ingress Protection test other than IPX0 (IP test)) |
- |
500 |
|
- |
15.2(Spillage Test) |
- |
500 |
|
- |
15.3(Humidity Test) |
- |
500 |
|
- |
16.0(General) |
- |
500 |
|
- |
16.1(General) |
- |
500 |
|
- |
16.2(Leakage Current (after Clause 15)) |
- |
500 |
|
- |
16.3(Electric Strength (after clause 15 and 16.2)) |
- |
500 |
|
- |
17(Over Load Protection of Transformers and associated circuits) |
- |
500 |
|
- |
18(Endurance) |
- |
500 |
|
- |
19(Abnormal Operation) |
- |
500 |
|
- |
20(Stability and mechanical hazards) |
- |
500 |
|
- |
20.1(Stability and mechanical hazards) |
- |
500 |
|
- |
19.17(Abnormal operation) |
- |
500 |
|
- |
21.2(Mechanical strength) |
- |
500 |
|
- |
21.3(Mechanical strength) |
- |
500 |
|
- |
22.5(Construction) |
- |
500 |
|
- |
22(Construction) |
- |
500 |
|
- |
22.6(Construction) |
- |
500 |
|
- |
22.11(Construction) |
- |
500 |
|
- |
22.32(Construction) |
- |
500 |
|
- |
22.42(Construction) |
- |
500 |
|
- |
23(Internal wiring) |
- |
500 |
|
- |
23.3(Internal wiring) |
- |
500 |
|
- |
24(Components) |
- |
500 |
|
- |
25(Supply connection and external flexible cords) |
- |
500 |
|
- |
25.7(Supply connection and external flexible cords) |
- |
500 |
|
- |
25.14(Supply connection and external flexible cords) |
- |
500 |
|
- |
25.15(Supply connection and external flexible cords) |
- |
500 |
|
- |
26(Terminals for external conductors) |
- |
500 |
|
- |
26.5(Terminals for external conductors) |
- |
500 |
|
- |
27(Provision for earthing) |
- |
500 |
|
- |
27.5(Provision for earthing) |
- |
500 |
|
- |
28(Screw test and connections) |
- |
500 |
|
- |
28.1(Screws and connections) |
- |
500 |
|
- |
29(clearance, creepage distances and solid insulation) |
- |
500 |
|
- |
30.1(Ball pressure test) |
- |
500 |
|
- |
30.2(Glow Wire Test) |
- |
500 |
|
- |
30.2(Needle Flame Test) |
- |
500 |
|
- |
31(Resistance to Rusting) |
- |
500 |
|
- |
A.2(Earth continuity test) |
- |
500 |
|
- |
B.22.1(Construction) |
- |
500 |
|
- |
B.22.3(Construction) |
- |
500 |
|
- |
B.22.4(Construction) |
- |
500 |
|
- |
B.22.5(Construction) |
- |
500 |
|
- |
Annex C(Ageing test on motors) |
- |
500 |
|
- |
12(Charging of metal-ion batteries) |
- |
500 |
|
- |
18(Endurance) |
- |
500 |
|
- |
16(Leakage current and electric strength) |
- |
500 |
|
- |
25(Supply connection and external flexible cords) |
- |
500 |
|
- |
21(Mechanical Strength) |
- |
500 |
|
- |
11.3(Heating) |
- |
500 |
|
- |
11.1(General) |
- |
500 |
|
- |
17(Overload protection of transformers and associated circuits) |
- |
500 |
|
- |
15.2(Moisture resistance) |
- |
500 |
|
- |
5(General conditions for the tests) |
- |
500 |
|
- |
6(Classification) |
- |
500 |
|
- |
7(Marking and instructions) |
- |
500 |
|
- |
8.1.5(Live parts of built-in appliances) |
- |
500 |
|
- |
4(General requirement) |
- |
500 |
|
- |
8.1.1(Protection against live parts in all positions) |
- |
500 |
|
- |
8.1.2(Protection against live parts in openings) |
- |
500 |
|
- |
8.1.3(Protection against live parts in visible glowing heating elements) |
- |
500 |
|
- |
8.1.4(Protection against live parts against protective impedance) |
- |
500 |
|
- |
9(Starting of motor operation test requirements and tests) |
- |
500 |
|
- |
10.1(Power input) |
- |
500 |
|
- |
10.2(Current input) |
- |
500 |
|
- |
11.2(General) |
- |
500 |
|
- |
11.4(Heating appliances) |
- |
500 |
|
- |
11.5(Motor-operated appliances) |
- |
500 |
|
- |
11.6(Combined appliances) |
- |
500 |
|
- |
11.7(Duration corresponding) |
- |
500 |
|
- |
11.8(Temperature rise) |
- |
500 |
|
- |
13(Leakage current and electric strength at operating temperature) |
- |
500 |
|
- |
13.2(Leakage current at operating temperature) |
- |
500 |
|
- |
13.3(Electric Strength at operating temperature) |
- |
500 |
|
- |
14(Transient Over Voltages) |
- |
500 |
|
- |
15.0(Moisture resistance) |
- |
500 |
|
- |
15.1(Ingress Protection test other than IPX0 (IP test)) |
- |
500 |
|
- |
15.2(Spillage Test) |
- |
500 |
|
- |
15.3(Humidity Test) |
- |
500 |
|
- |
16.0(General) |
- |
500 |
|
- |
16.1(General) |
- |
500 |
|
- |
16.2(Leakage Current (after Clause 15)) |
- |
500 |
|
- |
16.3(Electric Strength (after clause 15 and 16.2)) |
- |
500 |
|
- |
17(Over Load Protection of Transformers and associated circuits) |
- |
500 |
|
- |
18(Endurance) |
- |
500 |
|
- |
19(Abnormal Operation) |
- |
500 |
|
- |
20(Stability and mechanical hazards) |
- |
500 |
|
- |
20.1(Stability and mechanical hazards) |
- |
500 |
|
- |
19.17(Abnormal operation) |
- |
500 |
|
- |
21.2(Mechanical strength) |
- |
500 |
|
- |
21.3(Mechanical strength) |
- |
500 |
|
- |
22.5(Construction) |
- |
500 |
|
- |
22(Construction) |
- |
500 |
|
- |
22.6(Construction) |
- |
500 |
|
- |
22.11(Construction) |
- |
500 |
|
- |
22.32(Construction) |
- |
500 |
|
- |
22.42(Construction) |
- |
500 |
|
- |
23(Internal wiring) |
- |
500 |
|
- |
23.3(Internal wiring) |
- |
500 |
|
- |
24(Components) |
- |
500 |
|
- |
25(Supply connection and external flexible cords) |
- |
500 |
|
- |
25.7(Supply connection and external flexible cords) |
- |
500 |
|
- |
25.14(Supply connection and external flexible cords) |
- |
500 |
|
- |
25.15(Supply connection and external flexible cords) |
- |
500 |
|
- |
26(Terminals for external conductors) |
- |
500 |
|
- |
26.5(Terminals for external conductors) |
- |
500 |
|
- |
27(Provision for earthing) |
- |
500 |
|
- |
27.5(Provision for earthing) |
- |
500 |
|
- |
28(Screw test and connections) |
- |
500 |
|
- |
28.1(Screws and connections) |
- |
500 |
|
- |
29(clearance, creepage distances and solid insulation) |
- |
500 |
|
- |
30.1(Ball pressure test) |
- |
500 |
|
- |
30.2(Glow Wire Test) |
- |
500 |
|
- |
30.2(Needle Flame Test) |
- |
500 |
|
- |
31(Resistance to Rusting) |
- |
500 |
|
- |
A.2(Earth continuity test) |
- |
500 |
|
- |
B.22.1(Construction) |
- |
500 |
|
- |
B.22.3(Construction) |
- |
500 |
|
- |
B.22.4(Construction) |
- |
500 |
|
- |
B.22.5(Construction) |
- |
500 |
|
- |
Annex C(Ageing test on motors) |
- |
500 |
|
- |
12(Charging of metal-ion batteries) |
- |
500 |
|
- |
18(Endurance) |
- |
500 |
|
- |
16(Leakage current and electric strength) |
- |
500 |
|
- |
25(Supply connection and external flexible cords) |
- |
500 |
|
- |
21(Mechanical Strength) |
- |
500 |
|
- |
11.3(Heating) |
- |
500 |
|
- |
11.1(General) |
- |
500 |
|
- |
17(Overload protection of transformers and associated circuits) |
- |
500 |
|
- |
15.2(Moisture resistance) |
- |
500 |
|
- |
5(General conditions for the tests) |
- |
- |
|
- |
6(Classification) |
- |
- |
|
- |
7(Marking and instructions) |
- |
- |
|
- |
8.1.5(Live parts of built-in appliances) |
- |
- |
|
- |
4(General requirement) |
- |
- |
|
- |
8.1.1(Protection against live parts in all positions) |
- |
- |
|
- |
8.1.2(Protection against live parts in openings) |
- |
- |
|
- |
8.1.3(Protection against live parts in visible glowing heating elements) |
- |
- |
|
- |
8.1.4(Protection against live parts against protective impedance) |
- |
- |
|
- |
9(Starting of motor operation test requirements and tests) |
- |
- |
|
- |
10.1(Power input) |
- |
- |
|
- |
10.2(Current input) |
- |
- |
|
- |
11.2(General) |
- |
- |
|
- |
11.4(Heating appliances) |
- |
- |
|
- |
11.5(Motor-operated appliances) |
- |
- |
|
- |
11.6(Combined appliances) |
- |
- |
|
- |
11.7(Duration corresponding) |
- |
- |
|
- |
11.8(Temperature rise) |
- |
- |
|
- |
13(Leakage current and electric strength at operating temperature) |
- |
- |
|
- |
13.2(Leakage current at operating temperature) |
- |
- |
|
- |
13.3(Electric Strength at operating temperature) |
- |
- |
|
- |
14(Transient Over Voltages) |
- |
- |
|
- |
15.0(Moisture resistance) |
- |
- |
|
- |
15.1(Ingress Protection test other than IPX0 (IP test)) |
- |
- |
|
- |
15.2(Spillage Test) |
- |
- |
|
- |
15.3(Humidity Test) |
- |
- |
|
- |
16.0(General) |
- |
- |
|
- |
16.1(General) |
- |
- |
|
- |
16.2(Leakage Current (after Clause 15)) |
- |
- |
|
- |
16.3(Electric Strength (after clause 15 and 16.2)) |
- |
- |
|
- |
17(Over Load Protection of Transformers and associated circuits) |
- |
- |
|
- |
18(Endurance) |
- |
- |
|
- |
19(Abnormal Operation) |
- |
- |
|
- |
20(Stability and mechanical hazards) |
- |
- |
|
- |
20.1(Stability and mechanical hazards) |
- |
- |
|
- |
19.17(Abnormal operation) |
- |
- |
|
- |
21.2(Mechanical strength) |
- |
- |
|
- |
21.3(Mechanical strength) |
- |
- |
|
- |
22.5(Construction) |
- |
- |
|
- |
22(Construction) |
- |
- |
|
- |
22.6(Construction) |
- |
- |
|
- |
22.11(Construction) |
- |
- |
|
- |
22.32(Construction) |
- |
- |
|
- |
22.42(Construction) |
- |
- |
|
- |
23(Internal wiring) |
- |
- |
|
- |
23.3(Internal wiring) |
- |
- |
|
- |
24(Components) |
- |
- |
|
- |
25(Supply connection and external flexible cords) |
- |
- |
|
- |
25.7(Supply connection and external flexible cords) |
- |
- |
|
- |
25.14(Supply connection and external flexible cords) |
- |
- |
|
- |
25.15(Supply connection and external flexible cords) |
- |
- |
|
- |
26(Terminals for external conductors) |
- |
- |
|
- |
26.5(Terminals for external conductors) |
- |
- |
|
- |
27(Provision for earthing) |
- |
- |
|
- |
27.5(Provision for earthing) |
- |
- |
|
- |
28(Screw test and connections) |
- |
- |
|
- |
28.1(Screws and connections) |
- |
- |
|
- |
29(clearance, creepage distances and solid insulation) |
- |
- |
|
- |
30.1(Ball pressure test) |
- |
- |
|
- |
30.2(Glow Wire Test) |
- |
- |
|
- |
30.2(Needle Flame Test) |
- |
- |
|
- |
31(Resistance to Rusting) |
- |
- |
|
- |
A.2(Earth continuity test) |
- |
- |
|
- |
B.22.1(Construction) |
- |
- |
|
- |
B.22.3(Construction) |
- |
- |
|
- |
B.22.4(Construction) |
- |
- |
|
- |
B.22.5(Construction) |
- |
- |
|
- |
Annex C(Ageing test on motors) |
- |
- |
|
- |
12(Charging of metal-ion batteries) |
- |
- |
|
- |
18(Endurance) |
- |
- |
|
- |
16(Leakage current and electric strength) |
- |
- |
|
- |
25(Supply connection and external flexible cords) |
- |
- |
|
- |
21(Mechanical Strength) |
- |
- |
|
- |
11.3(Heating) |
- |
- |
|
- |
11.1(General) |
- |
- |
|
- |
17(Overload protection of transformers and associated circuits) |
- |
- |
|
- |
15.2(Moisture resistance) |
- |
- |
|
- |
|
03 Dec, 2026 |
- Included w.e.f 09.06.2025 Exclusion: Cl 19.11.4.1-19.11.4.7 (EMI/EMC), Cl 22.16 (Construction) |
28 |
Conformity Testing Labs Pvt. Ltd. Unit 2
| IS 302 : Part 2 : Sec 11 (1994) |
Safety of household and similar electrical appliances: Part 2 particular requirements: Sec 11 tumbler dryers |
- |
180000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
3(GENERAL REQUIREMENT) |
- |
0 |
|
- |
4(GENERAL NOTES ON TESTS) |
- |
0 |
|
- |
5(RATING) |
- |
0 |
|
- |
6(CLASSIFICATION) |
- |
0 |
|
- |
7(MARKING) |
- |
0 |
|
- |
8(PROTECTION AGAINST ELECTRIC SHOCK) |
- |
0 |
|
- |
9(STARTING OF MOTOR-OPERATED APPLIANCES) |
- |
0 |
|
- |
10(INPUT AND CURRENT) |
- |
0 |
|
- |
11(HEATING) |
- |
0 |
|
- |
13(ELECTRICAL INSULATION AND LEAKAGE CURRENT AT
OPERATING TEMPERATURE) |
- |
0 |
|
- |
15(MOISTURE RESISTANCE) |
- |
0 |
|
- |
17(OVERLOAD PROTECTION) |
- |
0 |
|
- |
18(ENDURANCE ) |
- |
0 |
|
- |
19(ABNORMAL OPERATION) |
- |
0 |
|
- |
20(STABILITY AND MECHANICAL HAZARDS) |
- |
0 |
|
- |
21(MECHANICAL STRENGTH) |
- |
0 |
|
- |
22(CONSTRUCTION) |
- |
0 |
|
- |
23(INTERNAL WIRING) |
- |
0 |
|
- |
24(COMPONENTS) |
- |
0 |
|
- |
25(SUPPLY CONNECTION AND EXTERNAL FLEXIBLE CABLES AND CORDS) |
- |
0 |
|
- |
26(TERMINALS FOR EXTERNAL CONDUCTORS) |
- |
0 |
|
- |
27(PROVISION FOR EARTHING) |
- |
0 |
|
- |
28(SCREWS AND CONNECTIONS) |
- |
0 |
|
- |
29(CREEPAGE DISTANCES, CLEARANCES AND DISTANCES THROUGH INSULATION) |
- |
0 |
|
- |
31(RESISTANCE TO RUSTING) |
- |
0 |
|
- |
32(RADIATION, TOXICITY AND SIMILAR HAZARDS) |
- |
0 |
|
- |
12(OPERATION TJNDER OVERLOAD CONDITIONS
OF APPLIANCES WITH HEATING ELEMENTS) |
- |
0 |
|
- |
14(RADIO AND TELEVISION INTERFERENCE SUPPRESSION) |
- |
0 |
|
- |
16(INSULATION RESISTANCE AND ELECTRIC STRENGTH) |
- |
0 |
|
- |
30(RESISTANCE TO HEAT, FIRE AND TACKING) |
- |
0 |
|
- |
101.1(Type Tests) |
- |
0 |
|
- |
101.2(Acceptance Tests) |
- |
0 |
|
- |
101.3(Routine Tests) |
- |
0 |
|
- |
|
05 Apr, 2027 |
- Included w.e.f.21.05.2025
Exclusion
19 (ABNORMAL OPERATION)
Radiated emission, Conducted & Radiated susceptibility |
29 |
Aaditech Test and Calibration Lab LLP
| IS 302 : Part 1 (2024) |
Household and Similar Electrical Appliances â Safety Part 1 General Requirements (Seventh Revision) |
- |
22000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
12(Charging of metal-ion batteries) |
- |
1000 |
|
- |
6(Classification) |
- |
500 |
|
- |
5(General conditions for the tests) |
- |
500 |
|
- |
11.8(Temperature rise) |
- |
1000 |
|
- |
11.7(Duration corresponding) |
- |
1000 |
|
- |
11.6(Combined appliances) |
- |
1000 |
|
- |
11.5(Motor-operated appliances) |
- |
1000 |
|
- |
11.4(Heating appliances) |
- |
1000 |
|
- |
8.1.5(Live parts of built-in appliances) |
- |
1000 |
|
- |
18(Endurance) |
- |
2000 |
|
- |
17(Overload protection of transformers and associated circuits) |
- |
1000 |
|
- |
16(Leakage current and electric strength) |
- |
1000 |
|
- |
4(General requirement) |
- |
500 |
|
- |
32(Radiation Toxicity and Similar Hazards) |
- |
1000 |
|
- |
31(Resistance to Rusting) |
- |
1000 |
|
- |
30.2(Needle Flame Test) |
- |
1000 |
|
- |
30.2(Glow Wire Test) |
- |
1000 |
|
- |
30.1(Ball pressure test) |
- |
1000 |
|
- |
29(clearance, creepage distances and solid insulation) |
- |
1000 |
|
- |
28(Screw test and connections) |
- |
1000 |
|
- |
27(Provision for earthing) |
- |
1000 |
|
- |
26(Terminals for external conductors) |
- |
1000 |
|
- |
25(Supply connection and external flexible cords) |
- |
1000 |
|
- |
24(Components) |
- |
1000 |
|
- |
23(Internal wiring) |
- |
1000 |
|
- |
22(Construction) |
- |
2000 |
|
- |
21(Mechanical Strength) |
- |
1000 |
|
- |
20(Stability and mechanical hazards) |
- |
1000 |
|
- |
19(Abnormal Operation) |
- |
2000 |
|
- |
18(Endurance) |
- |
2000 |
|
- |
16.3(Electric Strength (after clause 15 and 16.2)) |
- |
1000 |
|
- |
16.2(Leakage Current (after Clause 15)) |
- |
1000 |
|
- |
16.1(General) |
- |
1000 |
|
- |
16.0(General) |
- |
1000 |
|
- |
15.3(Humidity Test) |
- |
2000 |
|
- |
15.2(Spillage Test) |
- |
1000 |
|
- |
15.1(Ingress Protection test other than IPX0 (IP test)) |
- |
1000 |
|
- |
15.0(Moisture resistance) |
- |
1000 |
|
- |
14(Transient Over Voltages) |
- |
1000 |
|
- |
13.3(Electric Strength at operating temperature) |
- |
1000 |
|
- |
13.2(Leakage current at operating temperature) |
- |
1000 |
|
- |
13(Leakage current and electric strength at operating temperature) |
- |
1000 |
|
- |
11.3(Heating) |
- |
1000 |
|
- |
11.2(General) |
- |
500 |
|
- |
11.1(General) |
- |
500 |
|
- |
10.2(Current input) |
- |
1000 |
|
- |
10.1(Power input) |
- |
1000 |
|
- |
9(Starting of motor operation test requirements and tests) |
- |
1000 |
|
- |
8.1.4(Protection against live parts against protective impedance) |
- |
1000 |
|
- |
8.1.3(Protection against live parts in visible glowing heating elements) |
- |
1000 |
|
- |
8.1.2(Protection against live parts in openings) |
- |
1000 |
|
- |
8.1.1(Protection against live parts in all positions) |
- |
1000 |
|
- |
7(Marking and instructions) |
- |
1000 |
|
- |
A.2(Earth continuity test) |
- |
1000 |
|
- |
Annex C(Ageing test on motors) |
- |
2000 |
|
- |
Annex D(Thermal motor protectors) |
- |
2000 |
|
- |
15.2(Moisture resistance) |
- |
2000 |
|
- |
19.17(Abnormal operation) |
- |
2000 |
|
- |
20.1(Stability and mechanical hazards) |
- |
1000 |
|
- |
21.2(Mechanical strength) |
- |
1000 |
|
- |
21.3(Mechanical strength) |
- |
1000 |
|
- |
22.5(Construction) |
- |
1000 |
|
- |
22.6(Construction) |
- |
1000 |
|
- |
22.11(Construction) |
- |
1000 |
|
- |
22.16(Construction) |
- |
1000 |
|
- |
22.32(Construction) |
- |
1000 |
|
- |
22.42(Construction) |
- |
1000 |
|
- |
23.3(Internal wiring) |
- |
1000 |
|
- |
25(Supply connection and external flexible cords) |
- |
1000 |
|
- |
25.7(Supply connection and external flexible cords) |
- |
1000 |
|
- |
25.14(Supply connection and external flexible cords) |
- |
1000 |
|
- |
25.15(Supply connection and external flexible cords) |
- |
1000 |
|
- |
26.5(Terminals for external conductors) |
- |
1000 |
|
- |
27.5(Provision for earthing) |
- |
1000 |
|
- |
28.1(Screws and connections) |
- |
1000 |
|
- |
B.22.1(Construction) |
- |
1000 |
|
- |
B.22.3(Construction) |
- |
1000 |
|
- |
B.22.4(Construction) |
- |
1000 |
|
- |
B.22.5(Construction) |
- |
1000 |
|
- |
17(Over Load Protection of Transformers and associated circuits) |
- |
1000 |
|
- |
|
28 Aug, 2027 |
- Included w.e.f 19.05.2025
Exclusion: Cl 19.11.4.1-Cl 19.11.4.7(EMI/EMC) |
30 |
Conformity Testing Labs Pvt. Ltd. Unit 2
| IS 302 : Part 2 : Sec 8 (2024) |
Household and Similar Electrical Appliances âSafety Part 2 Particular Requirements Section 8 Shavers, Hair Clippers and Similar Appliances (First Revision) |
- |
70000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
7(Marking and instructions) |
- |
0 |
|
- |
8(Protection against access to live parts) |
- |
0 |
|
- |
10(Power input and current) |
- |
0 |
|
- |
11(Heating) |
- |
0 |
|
- |
12(Charging of metal-ion batteries) |
- |
0 |
|
- |
13.1 &13.2(Leakage current test) |
- |
0 |
|
- |
13.1 &13.3(Electric strength test) |
- |
0 |
|
- |
14(Transient overvoltages) |
- |
0 |
|
- |
15(Moisture resistance) |
- |
0 |
|
- |
15.3(Moisture resistance) |
- |
0 |
|
- |
16.1 &16.2(Leakage current test) |
- |
0 |
|
- |
16.1 & 16.3(Electric strength test) |
- |
0 |
|
- |
17(Overload protection of transformers and associated circuits) |
- |
0 |
|
- |
19.1 to 19.13, Table No. - 9(Abnormal operation) |
- |
0 |
|
- |
19.101(Abnormal operation) |
- |
0 |
|
- |
20.1(Stability and mechanical hazards) |
- |
0 |
|
- |
20.2(Stability and mechanical hazards) |
- |
0 |
|
- |
21(Mechanical strength) |
- |
0 |
|
- |
21.101(Mechanical strength) |
- |
0 |
|
- |
21.102(Mechanical strength) |
- |
0 |
|
- |
21.103(Mechanical strength) |
- |
0 |
|
- |
22(Construction) |
- |
0 |
|
- |
22.101(Construction) |
- |
0 |
|
- |
22.102(Construction) |
- |
0 |
|
- |
22.103(Construction) |
- |
0 |
|
- |
23(Internal wiring) |
- |
0 |
|
- |
24(Components) |
- |
0 |
|
- |
25("Supply connection and
external flexible cords") |
- |
0 |
|
- |
26("Terminals for external
conductors") |
- |
0 |
|
- |
27(Provision for earthing) |
- |
0 |
|
- |
28(Screws and connections) |
- |
0 |
|
- |
29("Clearances, creepage
distances and solid insulation") |
- |
0 |
|
- |
30(Resistance to heat and fire) |
- |
0 |
|
- |
31(Resistance to rusting) |
- |
0 |
|
- |
32("Radiation, toxicity and similar
hazards") |
- |
0 |
|
- |
19.11.4.1(Electrostatic discharges) |
- |
0 |
|
- |
19.11.4.3(Fast transient bursts) |
- |
0 |
|
- |
19.11.4.4(Surge immunity test) |
- |
0 |
|
- |
19.11.4.6(Class 3 Voltage dips and interruptions) |
- |
0 |
|
- |
|
05 Apr, 2027 |
- Included w.e.f 07.05.2025
Exclusion : Cl 19.11.4.2 (Radiated fields), Cl 19.11.4.5 (Immunity to conducted discharges), Cl 19.11.4.7 (Harmonics), Cl 24 (Components) |