S.No. Indian Standard No. Product Grade / Type / Size / Designation etc. Testing Charges (Excl. Of Taxes) Validity Date Remark
181 IS 9968 : Part 1 (1988) Specification for elastomer insulatedcables: Part 1 for working voltages up to and including 1100 volts (First Revision) - Rs.12000/ View breakup
-
- -
The following test facilities for clauses are not available: 1. Tear resistance test. 2. Water absorption (Electrical) Test for IE2 type elastomeric insulation
182 IS 9857 (1990) Welding cables - Specification (First Revision) - Rs 11400/- View breakup
-
- -
Complete test facility is available
183 IS 9537 : Part 3 (1983) Specification for conduits for electrical installations: Part 3 rigid plain conduits of insulating meterials - Please check remarks View breakup
-
- -
Complete test facility is available
184 IS 8783 : Part 4 : Sec 3 (1995) Winding wires for submersible motors - Specification: Part 4 specification for individual wires: Sec 3 polyester and polypropylene insulated winding wires (First Revision) - Rs.8700/- View breakup
-
- -
The following test facilities for clauses are not available: Cl 4.1 Thickness of Insulation (Separate measurement of Thickness of Polypropylene and Polyester)
185 IS 8783 : Part 4 : Sec 1 (1995) Winding wires for submersible motors - Specification: Part 4 specification for indmdual wires: Sec 1 HR PVC insulated wires (First Revision) - 9300/- View breakup
-
- -
-
186 IS 7098 : Part 1 (1988) Specification for crosslinked polyethylene insulated pvc sheathed cables: Part 1 for working voltages up to and including 1100 volts (First Revision) Except C1 & C2 category. 26250 View breakup
-
- -
Test facility not available for tests as per Clause 15.1.1 of C1 and C2 category
187 IS 4250 (1980) Specification for domestic electric food - Mixers (Liquidizers And Grinders) (First Revision) - Rs. 32600/- View breakup
-
- -
The following test facilities are not available: 1. Cl.14 Transient Overvoltage test (as per IS 302-1) 2. Cl.19.11 and 19.12 Abnormal Operation test (as perIS 302-1) (for electronic circuit) 3. Cl 24 component test as per IS302-1
188 IS 3975 (1999) Low carbon galvanized steel wires, formed wires and tapes for armouring of cables - Specification (Third Revision) - Rs 2700/- View breakup
-
- -
Test facility not available for the following: 1) Dimension radius R of formed wire.
189 IS 2465 (1984) Specification for cables for motor vehicles (Second Revision) Complete test facility for PVC Insulated General Wiring Single core PVC Insulated Unsheathed: Rs. 11030/- View breakup
-
- -
The following test facilities for ignition cables are not available: Cl 16 Capacitance, Cl 17 Ozone resistance, Cl 18 Effect of heat on flexibility, Cl 19 Effect of Oil test
190 IS 1293 (2019) Plugs and socket - Outlets of rated Voltage up to and including 250 Volts and rated current up to and including 16 amperes - Specification (Third Revision) UP TO 16A, 250V - View breakup
-
- -
Complete Test facility available
191 IS 398 : Part 5 (1992) Aluminium conductor for overhead transmission purposes - Specification: Part 5 aluminium conductors - Galvanized steel - Reinforced for extra high voltage (400 KV And Above) (First Revision) Except Test facility for clause 13.10, 13.11 and 13.12 11400 View breakup
-
- -
Test facility not available: 1. Breaking Load Test on Complete Conductor, 2. Surface conditioning test apparatus 3. Corona Test 4. Radio Interference Voltage Test.
192 IS 398 : Part 4 (1994) Aluminium conductors for overhead transmission purposes: Part 4 aluminium alloy stranded conductors (Aluminium - Magnesium - Silicon Type) - Specification (Third Revision) - Please see remarks View breakup
-
- -
Complete Test facility available
193 IS 398 : Part 1 (1996) Aluminium conductors for overhead transmission purposes - Specification: Part 1 aluminium stranded conductors (Third Revision) - Rs.1600/- for 7 strands, Rs.3750/- for 19 strands View breakup
-
- -
Complete Test Facility
194 IS 371 (1999) Ceiling roses - Specification (Third Revision) 6A, 250V Rs 5700/- View breakup
-
- -
-
195 IS 204 : Part 1 (1991) Tower bolts - Specification: Part 1 ferrous metals (Fifth Revision) - Rs.2100.00. View breakup
-
- -
Test facilities are not available for the following: (1) Finish
196 IS 12818 (2010) Unplasticized polyvinyl chloride (Pvc - U) screen and casing pipes for bore/tubewells - Specification (Second Revision) - Rs.6450.00 View breakup
-
- -
Remark 1: For measurement of the shore hardness of the sealing ring prepared button piece is required. Remark 2 : The following test facilities are not available: (1) For Outside Diameter above 250 mm, (2) Effect on water (3)Resistance to external blow
197 IS 398 : Part 2 (1996) Aluminium conductors for overhead transmission purposes - Specification: Part 2 aluminium conuuctors, galvanized steel - Reinforced (Third Revision) Up to 100 sq mm Please see remarks. View breakup
-
- -
Test facility not available for Cl. 13.9, 13.10 and 13.11 for size 100 sq.mm and above.
198 IS 3854 (1997) Switches for domestic and similar purposes - Specification (Second Revision) - Please see remarks. View breakup
-
- -
Complete TF is available for varieties upto and including 32 A.
199 IS 694 (2010) Polyvinyl chloride insulated unsheathed and sheathed cables/cords with rigid and flexible conductor for rated voltages up to and including 450/750 v (Fourth Revision) - Please see remarks View breakup
-
- -
Test facility not available for Copper purity test and FR/FRLSH category cables
200 IS 1554 : Part 1 (1988) Specification for pvc insulated (Heavy Duty) electric cables: Part 1 for working voltages up to and including 1100 v (Third Revision) - Rs 26700 View breakup
-
- -
Test facility not available for tests as per Cl. 15.1.1 of C1 and C2 category
201 IS 13334 : Part 1 (2014) Skimmed milk powder - Specification: Part 1 standard grade (Second Revision) - 10430/- View breakup
-
- -
(1) As per Cl. 5.7 The pesticide residues, heavy metals, toxins (aflatoxins and other naturally occurring toxins) and contaminants, if any, in the product shall not exceed the limits as prescribed in the Food Safety and Standards (Contaminants, Toxins and Residues) Regulations, 2011.’
202 IS 4984 (2016) Polyethylene pipes for water supply - Specification (Fifth Revision) - - View breakup
-
- -
The following test facilities are not available: (1) Internal Pressure creep rupture test (2)Tensile Strength for Butt-fusion (Clause 8.8) (3) Slow Crack Growth rate test (Clause 8.10) (4) Depth of strip (Clause 6.2.1) (5) Carbon Black content ( Clause 8.3) (6) For Size above 250 mm
203 IS 1786 (2008) High strength deformed steel bars and wires for concretere inforcement - Specification (Fourth Revision) - 25780 View breakup
-
- -
Test facilities are not available for the following: (1) Total elongation at maximum force, (2) Pull out test (Type test) (3) Sizes above 25 mm, (4) Micro-alloy/low alloys, Nb, V, B and Ti, Cr, Cu, Ni, Mo, Nirogen and nitrogen binding elements, like Nb, V, Ti, Al

Designed, Developed and Maintained by:

Arohatech IT Services (P) Ltd.