1 |
IS 1293 (2019) |
Plugs and socket - Outlets of rated Voltage up to and including 250 Volts and rated current up to and including 16 amperes - Specification (Third Revision) |
Upto and including 16A |
-
|
9500 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
6(RATINGS) |
- |
150 |
|
NIL |
7.1.1(Accessories Classification) |
- |
150 |
|
NIL |
7.1.2(Accessories Classification) |
- |
150 |
|
NIL |
7.1.3(Accessories Classification) |
- |
150 |
|
NIL |
7.1.4(Accessories Classification) |
- |
150 |
|
NIL |
7.1.5(Accessories Classification) |
- |
150 |
|
NIL |
7.2.1(Socket-Outlets Classification) |
- |
150 |
|
NIL |
7.2.2(Socket-Outlets Classification) |
- |
150 |
|
NIL |
7.2.3(Socket-Outlets Classification) |
- |
150 |
|
NIL |
7.2.4(Socket-Outlets Classification) |
- |
150 |
|
NIL |
7.3(Plug Classification) |
- |
150 |
|
NIL |
8(Marking) |
- |
150 |
|
NIL |
9(CHECKING OF DIMENSIONS) |
- |
500 |
|
NIL |
10(PROTECTION AGAINST ELECTRIC SHOCK) |
- |
400 |
|
NIL |
11(Provision for earthing) |
- |
400 |
|
NIL |
12(terminals) |
- |
500 |
|
NIL |
13.1(Construction of fixed Socket Outlets) |
- |
800 |
|
NIL |
13.2(Construction of fixed Socket Outlets) |
- |
800 |
|
NIL |
13.3(Construction of fixed Socket Outlets) |
- |
800 |
|
NIL |
13.4(Construction of fixed Socket Outlets) |
- |
800 |
|
NIL |
13.5(Construction of fixed Socket Outlets) |
- |
800 |
|
NIL |
13.6(Construction of fixed Socket Outlets) |
- |
800 |
|
NIL |
13.7(Construction of fixed Socket Outlets) |
- |
800 |
|
NIL |
13.8(Construction of fixed Socket Outlets) |
- |
800 |
|
NIL |
13.9(Construction of fixed Socket Outlets) |
- |
800 |
|
NIL |
13.10(Construction of fixed Socket Outlets) |
- |
800 |
|
NIL |
13.11(Construction of fixed Socket Outlets) |
- |
800 |
|
NIL |
13.12(Construction of fixed Socket Outlets) |
- |
800 |
|
NIL |
13.13(Construction of fixed Socket Outlets) |
- |
800 |
|
NIL |
13.14(Construction of fixed Socket Outlets) |
- |
800 |
|
NIL |
13.15(Construction of fixed Socket Outlets) |
- |
800 |
|
NIL |
13.16(Construction of fixed Socket Outlets) |
- |
800 |
|
NIL |
13.17(Construction of fixed Socket Outlets) |
- |
800 |
|
NIL |
13.18(Construction of fixed Socket Outlets) |
- |
800 |
|
NIL |
13.19(Construction of fixed Socket Outlets) |
- |
800 |
|
NIL |
13.2(Construction of fixed Socket Outlets) |
- |
800 |
|
NIL |
13.21(Construction of fixed Socket Outlets) |
- |
800 |
|
NIL |
13.22(Construction of fixed Socket Outlets) |
- |
800 |
|
NIL |
13.23(Construction of fixed Socket Outlets) |
- |
800 |
|
NIL |
14.1(CONSTRUCTION OF PLUGS AND PORTABLE SOCKETOUTLET) |
- |
800 |
|
NIL |
14.2(CONSTRUCTION OF PLUGS AND PORTABLE SOCKETOUTLET) |
- |
800 |
|
NIL |
14.3(CONSTRUCTION OF PLUGS AND PORTABLE SOCKETOUTLET) |
- |
800 |
|
NIL |
14.4(CONSTRUCTION OF PLUGS AND PORTABLE SOCKETOUTLET) |
- |
800 |
|
NIL |
14.5(CONSTRUCTION OF PLUGS AND PORTABLE SOCKETOUTLET) |
- |
800 |
|
NIL |
14.6(CONSTRUCTION OF PLUGS AND PORTABLE SOCKETOUTLET) |
- |
800 |
|
NIL |
14.7(CONSTRUCTION OF PLUGS AND PORTABLE SOCKETOUTLET) |
- |
800 |
|
NIL |
14.8(CONSTRUCTION OF PLUGS AND PORTABLE SOCKETOUTLET) |
- |
800 |
|
NIL |
14.9(CONSTRUCTION OF PLUGS AND PORTABLE SOCKETOUTLET) |
- |
800 |
|
NIL |
14.10(CONSTRUCTION OF PLUGS AND PORTABLE SOCKETOUTLET) |
- |
800 |
|
NIL |
14.11(CONSTRUCTION OF PLUGS AND PORTABLE SOCKETOUTLET) |
- |
800 |
|
NIL |
14.12(CONSTRUCTION OF PLUGS AND PORTABLE SOCKETOUTLET) |
- |
800 |
|
NIL |
14.13(CONSTRUCTION OF PLUGS AND PORTABLE SOCKETOUTLET) |
- |
800 |
|
NIL |
14.14(CONSTRUCTION OF PLUGS AND PORTABLE SOCKETOUTLET) |
- |
800 |
|
NIL |
14.15(CONSTRUCTION OF PLUGS AND PORTABLE SOCKETOUTLET) |
- |
800 |
|
NIL |
14.16(CONSTRUCTION OF PLUGS AND PORTABLE SOCKETOUTLET) |
- |
800 |
|
NIL |
14.17(CONSTRUCTION OF PLUGS AND PORTABLE SOCKETOUTLET) |
- |
800 |
|
NIL |
14.18(CONSTRUCTION OF PLUGS AND PORTABLE SOCKETOUTLET) |
- |
800 |
|
NIL |
14.19(CONSTRUCTION OF PLUGS AND PORTABLE SOCKETOUTLET) |
- |
800 |
|
NIL |
14.20(CONSTRUCTION OF PLUGS AND PORTABLE SOCKETOUTLET) |
- |
800 |
|
NIL |
14.21(CONSTRUCTION OF PLUGS AND PORTABLE SOCKETOUTLET) |
- |
800 |
|
NIL |
14.22(CONSTRUCTION OF PLUGS AND PORTABLE SOCKETOUTLET) |
- |
800 |
|
NIL |
14.23(CONSTRUCTION OF PLUGS AND PORTABLE SOCKETOUTLET) |
- |
800 |
|
NIL |
14.24(CONSTRUCTION OF PLUGS AND PORTABLE SOCKETOUTLET) |
- |
800 |
|
NIL |
14.25(CONSTRUCTION OF PLUGS AND PORTABLE SOCKETOUTLET) |
- |
800 |
|
NIL |
14.26(CONSTRUCTION OF PLUGS AND PORTABLE SOCKETOUTLET) |
- |
800 |
|
NIL |
15(INTERLOCKED SOCKET-OUTLETS) |
- |
400 |
|
NIL |
16.1(Resistance to Ageing) |
- |
500 |
|
NIL |
16.2(RESISTANCE TO HARMFUL INGRESS OF WATER AND TO HUMIDITY) |
- |
500 |
|
NIL |
16.3(Resistance to Humidity) |
- |
500 |
|
NIL |
17.1(RESISTANCE AND ELECTRIC STRENGTH) |
- |
700 |
|
NIL |
17.2(INSULATION RESISTANCE AND ELECTRIC STRENGTH) |
- |
700 |
|
NIL |
17.3(INSULATION RESISTANCE AND ELECTRIC STRENGTH) |
- |
700 |
|
NIL |
18(OPERATION OF EARTHING CONTACTS) |
- |
700 |
|
NIL |
19(TEMPERATURE RISE) |
- |
1000 |
|
NIL |
20(Making & Breaking Capacity) |
- |
1500 |
|
NIL |
21(Normal Operation) |
- |
2500 |
|
NIL |
22.1(Verification of the Maximum Withdrawal Force) |
- |
150 |
|
NIL |
22.2(Verification of Minimum Withdrawal Force) |
- |
150 |
|
NIL |
23.1(FLEXIBLE CABLES AND THEIR CONNECTION) |
- |
150 |
|
NIL |
23.2(FLEXIBLE CABLES AND THEIR CONNECTION) |
- |
150 |
|
NIL |
23.3(FLEXIBLE CABLES AND THEIR CONNECTION) |
- |
150 |
|
NIL |
23.4(FLEXIBLE CABLES AND THEIR CONNECTION) |
- |
150 |
|
NIL |
24.1(MECHANICAL STRENGTH For all kinds of fixed socketoutlets) |
- |
150 |
|
NIL |
24.1(MECHANICAL STRENGTH For portable multiple and combined socket outlets with enclosures, covers or bodies other than thermoplastic or elastomeric material) |
- |
150 |
|
NIL |
24.1(MECHANICAL STRENGTH For surface mounting boxes) |
- |
150 |
|
NIL |
24.2(MECHANICAL STRENGTH For portable single socket-outlets: 1) with enclosures, covers or bodies other than thermoplastic or elastomeric material) |
- |
150 |
|
NIL |
24.2(MECHANICAL STRENGTH For portable multiple and combined socket outlets: 1) with enclosures, covers and bodies of elastomeric or thermoplastic material) |
- |
150 |
|
NIL |
24.2(MECHANICAL STRENGTH For plug 1) with enclosures, covers and bodies of elastomeric or thermoplastic material) |
- |
150 |
|
NIL |
24.2(MECHANICAL STRENGTH For plug 1) with enclosures, covers and bodies of elastomeric or thermoplastic material) |
- |
150 |
|
NIL |
24.3(MECHANICAL STRENGTH for fixed socket-outlets with a main part intended to be mounted directly on a surface) |
- |
150 |
|
NIL |
24.4(MECHANICAL STRENGTH For portable single socket-outlets: 1) with enclosures, covers or bodies of thermoplastic or elastomeric material) |
- |
150 |
|
NIL |
24.4(MECHANICAL STRENGTH For portable multiple and combined socket outlets: 1) with enclosures, covers and bodies of elastomeric or thermoplastic material) |
- |
150 |
|
NIL |
24.5(MECHANICAL STRENGTH For portable single socket-outlets: 1) with enclosures, covers or bodies of thermoplastic or elastomeric material) |
- |
150 |
|
NIL |
24.5(MECHANICAL STRENGTH For portable multiple and combined socket outlets: 1) with enclosures, covers and bodies of elastomeric or thermoplastic material) |
- |
150 |
|
NIL |
24.5(MECHANICAL STRENGTH For Plug 1) with enclosures, covers and bodies of elastomeric or thermoplastic material) |
- |
150 |
|
NIL |
24.6(MECHANICAL STRENGTH For screwed glands of accessories having an IP code higher than IP20) |
- |
150 |
|
NIL |
24.7(MECHANICAL STRENGTH For plug pins provided with insulating sleeves) |
- |
150 |
|
NIL |
24.8(MECHANICAL STRENGTH For shuttered socketoutlets) |
- |
150 |
|
NIL |
24.9(MECHANICAL STRENGTH For portable multiple and combined socket outlets (1) with enclosures, covers or bodies other than thermoplastic or elastomeric material) |
- |
150 |
|
NIL |
24.9(MECHANICAL STRENGTH For portable multiple and combined socket outlets (1) with enclosures, covers or bodies other than thermoplastic or elastomeric material) |
- |
150 |
|
NIL |
24.10(MECHANICAL STRENGTH For Plug (1) with enclosures, covers or bodies other than thermoplastic or elastomeric material) |
- |
150 |
|
NIL |
24.10(MECHANICAL STRENGTH For Plug (1) with enclosures, covers or bodies of thermoplastic or elastomeric material) |
- |
150 |
|
NIL |
24.11(MECHANICAL STRENGTH For portable socketoutlets having means for suspension on a wall) |
- |
150 |
|
NIL |
24.12(MECHANICAL STRENGTH For portable socketoutlets having means for suspension on a wall) |
- |
150 |
|
NIL |
24.13(MECHANICAL STRENGTH For portable socketoutlets having means for suspension on a wall) |
- |
150 |
|
NIL |
24.14.1(MECHANICAL STRENGTH For fixed socket-outlets) |
- |
150 |
|
NIL |
24.14.2(MECHANICAL STRENGTH For fixed socket-outlets) |
- |
150 |
|
NIL |
24.14.3(MECHANICAL STRENGTH For plugs and portable socketoutlets) |
- |
150 |
|
NIL |
24.15(MECHANICAL STRENGTH) |
- |
150 |
|
NIL |
24.16(MECHANICAL STRENGTH) |
- |
150 |
|
NIL |
24.16(MECHANICAL STRENGTH For shroud of portable socket-outlets) |
- |
150 |
|
NIL |
25.1(Resistance to heat) |
- |
250 |
|
NIL |
25.2(Resistance to heat) |
- |
250 |
|
NIL |
25.3(Resistance to heat) |
- |
250 |
|
NIL |
25.4(Resistance to heat) |
- |
250 |
|
NIL |
26.1(SCREWS, CURRENTCARRYING PARTS AND CONNECTIONS) |
- |
100 |
|
NIL |
26.2(SCREWS, CURRENTCARRYING PARTS AND CONNECTIONS) |
- |
100 |
|
NIL |
26.3(SCREWS, CURRENTCARRYING PARTS AND CONNECTIONS) |
- |
100 |
|
NIL |
26.4(SCREWS, CURRENTCARRYING PARTS AND CONNECTIONS) |
- |
100 |
|
NIL |
26.5(SCREWS, CURRENTCARRYING PARTS AND CONNECTIONS) |
- |
100 |
|
NIL |
26.6(SCREWS, CURRENTCARRYING PARTS AND CONNECTIONS) |
- |
100 |
|
NIL |
26.7(SCREWS, CURRENTCARRYING PARTS AND CONNECTIONS) |
- |
100 |
|
NIL |
27.1(CREEPAGE DISTANCES, CLEARANCES AND DISTANCES THROUGH SEALING COMPOUND) |
- |
100 |
|
NIL |
27.2(CREEPAGE DISTANCES, CLEARANCES AND DISTANCES THROUGH SEALING COMPOUND) |
- |
100 |
|
NIL |
27.3(CREEPAGE DISTANCES, CLEARANCES AND DISTANCES THROUGH SEALING COMPOUND) |
- |
100 |
|
NIL |
28.1.1(Glow-Wire Test) |
- |
500 |
|
NIL |
28.2(Resistance to Tracking) |
- |
500 |
|
NIL |
29(Resistance to Rusting) |
- |
500 |
|
NIL |
30.1(ADDITIONAL TESTS ON PINS PROVIDED WITH INSULATING SLEEVES Pressure Test at High Temperature) |
- |
500 |
|
NIL |
30.2(ADDITIONAL TESTS ON PINS PROVIDED WITH INSULATING SLEEVES Static Damp Heat Test) |
- |
500 |
|
NIL |
30.3(ADDITIONAL TESTS ON PINS PROVIDED WITH INSULATING SLEEVES Tests at Low Temperature) |
- |
500 |
|
NIL |
30.4(ADDITIONAL TESTS ON PINS PROVIDED WITH INSULATING SLEEVES Impact Test at Low Temperature) |
- |
500 |
|
NIL |
|
Complete
|
19 Jul, 2024 |
06 Jun, 2027 |
- |
2 |
IS 1180 : Part 1 (2014) |
Outdoor Type Oil Immersed Distribution Transformers Upto and Including 2 500 kVA, 33kV - Specification Part 1 Mineral Oil Immersed (Fourth Revision) |
Upto and including 2500 KVA |
-
|
125000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
13.1(Marking (Rating Plates)) |
- |
100 |
|
NIL |
13.2(Terminal Marking Plate) |
- |
100 |
|
NIL |
13.3(Marking ) |
- |
100 |
|
NIL |
13.4(Marking) |
- |
100 |
|
NIL |
13.4.1(Marking) |
- |
100 |
|
NIL |
14.1(MOUNTING ARRANGEMENT) |
- |
100 |
|
NIL |
14.2(MOUNTING ARRANGEMENT) |
- |
100 |
|
NIL |
14.3(MOUNTING ARRANGEMENT) |
- |
100 |
|
NIL |
14.4(MOUNTING ARRANGEMENT) |
- |
100 |
|
NIL |
15.1.1(TRANSFORMER TANK : Construction) |
- |
100 |
|
NIL |
15.1.2(TRANSFORMER TANK : Construction) |
- |
100 |
|
NIL |
15.1.3(TRANSFORMER TANK : Construction) |
- |
100 |
|
NIL |
15.1.4(TRANSFORMER TANK : Construction) |
- |
100 |
|
NIL |
15.1.5(TRANSFORMER TANK : Construction) |
- |
100 |
|
NIL |
21.2 a)(Measurement of winding resistance ) |
- |
100 |
|
NIL |
21.2 b)( Measurement of voltage ratio and check of
phase displacemen) |
- |
4000 |
|
NIL |
21.2 c)( Measurement of short-circuit impedance
(principal tapping, when applicable) and load
loss at 50 percent and 100 percent load) |
- |
4000 |
|
NIL |
21.2 d)(Measurement of no-load loss and current) |
- |
4000 |
|
NIL |
21.2 e)(Measurement of insulation resistance) |
- |
2000 |
|
NIL |
21.2 f)(Induced over-voltage withstand test) |
- |
2000 |
|
NIL |
21.2 g)( Separate-source voltage withstand test) |
- |
2000 |
|
NIL |
21.5.3.3(Oil leakage test) |
- |
1000 |
|
NIL |
21.3(a )(Lightning impulse test) |
- |
5500 |
|
NIL |
21.3(b)(Temperature-rise test) |
- |
8000 |
|
NIL |
21.4 a)( Determination of sound levels) |
- |
2500 |
|
NIL |
21.5.1.1(Pressure test-Type test (For Transformers up to 200 kVA
)) |
- |
2500 |
|
NIL |
21.5.1.2(Pressure test-routine test (For Transformers up to 200 kVA
)) |
- |
2500 |
|
NIL |
21.5.2.1(Type test : For Transformers Above 200 kVA and Up to Including 2 500 kVA) |
- |
2500 |
|
NIL |
21.5.2.2(routine test :For Transformers Above 200 kVA and Up to Including 2 500 kVA) |
- |
2500 |
|
NIL |
21.5.2.3( Oil leakage test (routine test)) |
- |
2000 |
|
NIL |
21.5.3.1(For Single Phase Distribution Transformers Up to Including 25 kVA : pressure test (type test)) |
- |
2500 |
|
NIL |
21.5.3.2(For Single Phase Distribution Transformers Up to Including 25 kVA : pressure test (routine test)) |
- |
2500 |
|
NIL |
21.5.3.3(Oil leakage test (routine test)) |
- |
2500 |
|
NIL |
21.4 c(No load current at 112.5 percent voltage.) |
- |
45000 |
|
NIL |
21.4 d(Paint adhesion tests) |
- |
2500 |
|
NIL |
21.4 e(BDV and moisture content of oil in the transformer) |
- |
4000 |
|
NIL |
15.5(Total Dry Film Paint Thickness) |
- |
4000 |
|
NIL |
6.9, 7.9, 8.9(Permissible Flux Density and Over Fluxing) |
- |
2500 |
|
NIL |
11(Minimum clearance in Air) |
- |
1000 |
|
NIL |
16(Conservator for Non-sealed type Transformers) |
- |
1000 |
|
NIL |
20(Fittings) |
- |
1000 |
|
NIL |
6.8 (50%)(Total losses at 50 % load (Watts)) |
- |
2500 |
|
NIL |
7.8 (50%)(Total losses at 50 % load (Watts)) |
- |
2500 |
|
NIL |
8.8 (50%)(Total losses at 50 % load (Watts)) |
- |
2500 |
|
NIL |
6.8 (100%)(Total losses at 100 % load (Watts)) |
- |
2500 |
|
NIL |
7.8 (100%)(Total losses at 100 % load (Watts)) |
- |
2500 |
|
NIL |
8.8 (100%)(Total losses at 100 % load (Watts)) |
- |
2500 |
|
NIL |
21.5.1.3(Oil leakage test upto 200 KVA) |
- |
4000 |
|
NIL |
9.1a)(CRGO Electrical Steel) |
- |
200 |
|
NIL |
9.1 b)(Amorphous core material) |
- |
200 |
|
NIL |
9.1 c)(Copper/Aluminium conductor) |
- |
200 |
|
NIL |
9.1 d)(Kraft paper) |
- |
200 |
|
NIL |
9.1 e)(Press Board) |
- |
200 |
|
NIL |
9.1 f)(Mineral oil) |
- |
200 |
|
NIL |
10(Terminal Arrangement) |
- |
200 |
|
NIL |
15.2(Pressure and Vacuum Requirements) |
- |
200 |
|
NIL |
15.4(Gasket) |
- |
200 |
|
NIL |
19(Tolerances) |
- |
200 |
|
NIL |
18(Efficiency and regulation) |
- |
1000 |
|
NIL |
4(Service Conditions) |
- |
200 |
|
NIL |
5(General ) |
- |
200 |
|
NIL |
6.1(Rating) |
- |
200 |
|
NIL |
6.2(Rated frequency) |
- |
200 |
|
NIL |
6.3(Nominal system voltage) |
- |
200 |
|
NIL |
6.4(Basic Insulation level ) |
- |
200 |
|
NIL |
6.5(No-Load Voltage Ratios) |
- |
1000 |
|
NIL |
6.6(Winding connections and phase displacement) |
- |
2000 |
|
NIL |
6.7(Tapping Range and Tapping Method) |
- |
2000 |
|
NIL |
6.8(Losses and impedance values) |
- |
1000 |
|
NIL |
6.9(Permissible Flux Density and Over Fluxing ) |
- |
1000 |
|
NIL |
6.1(Limits of Temperature-rise) |
- |
2500 |
|
NIL |
7(Technical Parameters of three phase distribution trasnformers
higher than 200kva) |
- |
1000 |
|
NIL |
8(Technical Parameters of single phase distribution transformers
UP to and including 25 KVA ) |
- |
1000 |
|
NIL |
9(Standard Materials) |
- |
1000 |
|
NIL |
10(Terminal arrangment ) |
- |
1000 |
|
NIL |
11(Minimum Clearnaces air ) |
- |
1000 |
|
NIL |
12(Connectors ) |
- |
100 |
|
NIL |
13(Marking ) |
- |
200 |
|
NIL |
14(Mounting arrangement) |
- |
200 |
|
NIL |
15(Trasnformer Tank ) |
- |
200 |
|
NIL |
16(Conservator for Non-Sealed type Transformers) |
- |
200 |
|
NIL |
18(Efficiency and Regulation) |
- |
1000 |
|
NIL |
19(Tolerances) |
- |
200 |
|
NIL |
20(Fittings) |
- |
200 |
|
NIL |
21(General ) |
- |
200 |
|
NIL |
22(Information required with enquiry and order ) |
- |
200 |
|
NIL |
13.1(Marking (Rating Plates)) |
- |
100 |
|
NIL |
13.2(Terminal Marking Plate) |
- |
100 |
|
NIL |
13.3(Marking ) |
- |
100 |
|
NIL |
13.4(Marking) |
- |
100 |
|
NIL |
13.4.1(Marking) |
- |
100 |
|
NIL |
14.1(MOUNTING ARRANGEMENT) |
- |
100 |
|
NIL |
14.2(MOUNTING ARRANGEMENT) |
- |
100 |
|
NIL |
14.3(MOUNTING ARRANGEMENT) |
- |
100 |
|
NIL |
14.4(MOUNTING ARRANGEMENT) |
- |
100 |
|
NIL |
15.1.1(TRANSFORMER TANK : Construction) |
- |
100 |
|
NIL |
15.1.2(TRANSFORMER TANK : Construction) |
- |
100 |
|
NIL |
15.1.3(TRANSFORMER TANK : Construction) |
- |
100 |
|
NIL |
15.1.4(TRANSFORMER TANK : Construction) |
- |
100 |
|
NIL |
15.1.5(TRANSFORMER TANK : Construction) |
- |
100 |
|
NIL |
21.2 a)(Measurement of winding resistance ) |
- |
100 |
|
NIL |
21.2 b)( Measurement of voltage ratio and check of
phase displacemen) |
- |
4000 |
|
NIL |
21.2 c)( Measurement of short-circuit impedance
(principal tapping, when applicable) and load
loss at 50 percent and 100 percent load) |
- |
4000 |
|
NIL |
21.2 d)(Measurement of no-load loss and current) |
- |
4000 |
|
NIL |
21.2 e)(Measurement of insulation resistance) |
- |
2000 |
|
NIL |
21.2 f)(Induced over-voltage withstand test) |
- |
2000 |
|
NIL |
21.2 g)( Separate-source voltage withstand test) |
- |
2000 |
|
NIL |
21.5.3.3(Oil leakage test) |
- |
1000 |
|
NIL |
21.3(a )(Lightning impulse test) |
- |
5500 |
|
NIL |
21.3(b)(Temperature-rise test) |
- |
8000 |
|
NIL |
21.4 a)( Determination of sound levels) |
- |
2500 |
|
NIL |
21.5.1.1(Pressure test-Type test (For Transformers up to 200 kVA
)) |
- |
2500 |
|
NIL |
21.5.1.2(Pressure test-routine test (For Transformers up to 200 kVA
)) |
- |
2500 |
|
NIL |
21.5.2.1(Type test : For Transformers Above 200 kVA and Up to Including 2 500 kVA) |
- |
2500 |
|
NIL |
21.5.2.2(routine test :For Transformers Above 200 kVA and Up to Including 2 500 kVA) |
- |
2500 |
|
NIL |
21.5.2.3( Oil leakage test (routine test)) |
- |
2000 |
|
NIL |
21.5.3.1(For Single Phase Distribution Transformers Up to Including 25 kVA : pressure test (type test)) |
- |
2500 |
|
NIL |
21.5.3.2(For Single Phase Distribution Transformers Up to Including 25 kVA : pressure test (routine test)) |
- |
2500 |
|
NIL |
21.5.3.3(Oil leakage test (routine test)) |
- |
2500 |
|
NIL |
21.4 c(No load current at 112.5 percent voltage.) |
- |
45000 |
|
NIL |
21.4 d(Paint adhesion tests) |
- |
2500 |
|
NIL |
21.4 e(BDV and moisture content of oil in the transformer) |
- |
4000 |
|
NIL |
15.5(Total Dry Film Paint Thickness) |
- |
4000 |
|
NIL |
6.9, 7.9, 8.9(Permissible Flux Density and Over Fluxing) |
- |
2500 |
|
NIL |
11(Minimum clearance in Air) |
- |
1000 |
|
NIL |
16(Conservator for Non-sealed type Transformers) |
- |
1000 |
|
NIL |
20(Fittings) |
- |
1000 |
|
NIL |
6.8 (50%)(Total losses at 50 % load (Watts)) |
- |
2500 |
|
NIL |
7.8 (50%)(Total losses at 50 % load (Watts)) |
- |
2500 |
|
NIL |
8.8 (50%)(Total losses at 50 % load (Watts)) |
- |
2500 |
|
NIL |
6.8 (100%)(Total losses at 100 % load (Watts)) |
- |
2500 |
|
NIL |
7.8 (100%)(Total losses at 100 % load (Watts)) |
- |
2500 |
|
NIL |
8.8 (100%)(Total losses at 100 % load (Watts)) |
- |
2500 |
|
NIL |
21.5.1.3(Oil leakage test upto 200 KVA) |
- |
4000 |
|
NIL |
9.1a)(CRGO Electrical Steel) |
- |
200 |
|
NIL |
9.1 b)(Amorphous core material) |
- |
200 |
|
NIL |
9.1 c)(Copper/Aluminium conductor) |
- |
200 |
|
NIL |
9.1 d)(Kraft paper) |
- |
200 |
|
NIL |
9.1 e)(Press Board) |
- |
200 |
|
NIL |
9.1 f)(Mineral oil) |
- |
200 |
|
NIL |
10(Terminal Arrangement) |
- |
200 |
|
NIL |
15.2(Pressure and Vacuum Requirements) |
- |
200 |
|
NIL |
15.4(Gasket) |
- |
200 |
|
NIL |
19(Tolerances) |
- |
200 |
|
NIL |
18(Efficiency and regulation) |
- |
1000 |
|
NIL |
4(Service Conditions) |
- |
200 |
|
NIL |
5(General ) |
- |
200 |
|
NIL |
6.1(Rating) |
- |
200 |
|
NIL |
6.2(Rated frequency) |
- |
200 |
|
NIL |
6.3(Nominal system voltage) |
- |
200 |
|
NIL |
6.4(Basic Insulation level ) |
- |
200 |
|
NIL |
6.5(No-Load Voltage Ratios) |
- |
200 |
|
NIL |
6.6(Winding connections and phase displacement) |
- |
200 |
|
NIL |
6.7(Tapping Range and Tapping Method) |
- |
2000 |
|
NIL |
6.8(Losses and impedance values) |
- |
2000 |
|
NIL |
6.9(Permissible Flux Density and Over Fluxing ) |
- |
1000 |
|
NIL |
6.1(Limits of Temperature-rise) |
- |
200 |
|
NIL |
7(Technical Parameters of three phase distribution trasnformers
higher than 200kva) |
- |
200 |
|
NIL |
8(Technical Parameters of single phase distribution transformers
UP to and including 25 KVA ) |
- |
200 |
|
NIL |
9(Standard Materials) |
- |
200 |
|
NIL |
10(Terminal arrangment ) |
- |
200 |
|
NIL |
11(Minimum Clearnaces air ) |
- |
1000 |
|
NIL |
12(Connectors ) |
- |
200 |
|
NIL |
13(Marking ) |
- |
200 |
|
NIL |
14(Mounting arrangement) |
- |
200 |
|
NIL |
15(Trasnformer Tank ) |
- |
200 |
|
NIL |
16(Conservator for Non-Sealed type Transformers) |
- |
200 |
|
NIL |
18(Efficiency and Regulation) |
- |
1000 |
|
NIL |
19(Tolerances) |
- |
200 |
|
NIL |
20(Fittings) |
- |
200 |
|
NIL |
21(General ) |
- |
200 |
|
NIL |
22(Information required with enquiry and order ) |
- |
200 |
|
NIL |
13.1(Marking (Rating Plates)) |
- |
100 |
|
NIL |
13.2(Terminal Marking Plate) |
- |
100 |
|
NIL |
13.3(Marking ) |
- |
100 |
|
NIL |
13.4(Marking) |
- |
100 |
|
NIL |
13.4.1(Marking) |
- |
100 |
|
NIL |
14.1(MOUNTING ARRANGEMENT) |
- |
100 |
|
NIL |
14.2(MOUNTING ARRANGEMENT) |
- |
100 |
|
NIL |
14.3(MOUNTING ARRANGEMENT) |
- |
100 |
|
NIL |
14.4(MOUNTING ARRANGEMENT) |
- |
100 |
|
NIL |
15.1.1(TRANSFORMER TANK : Construction) |
- |
100 |
|
NIL |
15.1.2(TRANSFORMER TANK : Construction) |
- |
100 |
|
NIL |
15.1.3(TRANSFORMER TANK : Construction) |
- |
100 |
|
NIL |
15.1.4(TRANSFORMER TANK : Construction) |
- |
100 |
|
NIL |
15.1.5(TRANSFORMER TANK : Construction) |
- |
100 |
|
NIL |
21.2 a)(Measurement of winding resistance ) |
- |
4000 |
|
NIL |
21.2 b)( Measurement of voltage ratio and check of
phase displacemen) |
- |
4000 |
|
NIL |
21.2 c)( Measurement of short-circuit impedance
(principal tapping, when applicable) and load
loss at 50 percent and 100 percent load) |
- |
4000 |
|
NIL |
21.2 d)(Measurement of no-load loss and current) |
- |
4000 |
|
NIL |
21.2 e)(Measurement of insulation resistance) |
- |
2000 |
|
NIL |
21.2 f)(Induced over-voltage withstand test) |
- |
2000 |
|
NIL |
21.2 g)( Separate-source voltage withstand test) |
- |
2000 |
|
NIL |
21.5.3.3(Oil leakage test) |
- |
1000 |
|
NIL |
21.3(a )(Lightning impulse test) |
- |
5500 |
|
NIL |
21.3(b)(Temperature-rise test) |
- |
8000 |
|
NIL |
21.4 a)( Determination of sound levels) |
- |
2500 |
|
NIL |
21.5.1.1(Pressure test-Type test (For Transformers up to 200 kVA
)) |
- |
2500 |
|
NIL |
21.5.1.2(Pressure test-routine test (For Transformers up to 200 kVA
)) |
- |
2500 |
|
NIL |
21.5.2.1(Type test : For Transformers Above 200 kVA and Up to Including 2 500 kVA) |
- |
2500 |
|
NIL |
21.5.2.2(routine test :For Transformers Above 200 kVA and Up to Including 2 500 kVA) |
- |
2500 |
|
NIL |
21.5.2.3( Oil leakage test (routine test)) |
- |
2000 |
|
NIL |
21.5.3.1(For Single Phase Distribution Transformers Up to Including 25 kVA : pressure test (type test)) |
- |
2500 |
|
NIL |
21.5.3.2(For Single Phase Distribution Transformers Up to Including 25 kVA : pressure test (routine test)) |
- |
2500 |
|
NIL |
21.5.3.3(Oil leakage test (routine test)) |
- |
2500 |
|
NIL |
21.4 c(No load current at 112.5 percent voltage.) |
- |
45000 |
|
NIL |
21.4 d(Paint adhesion tests) |
- |
2500 |
|
NIL |
21.4 e(BDV and moisture content of oil in the transformer) |
- |
4000 |
|
NIL |
15.5(Total Dry Film Paint Thickness) |
- |
4000 |
|
NIL |
6.9, 7.9, 8.9(Permissible Flux Density and Over Fluxing) |
- |
2500 |
|
NIL |
11(Minimum clearance in Air) |
- |
1000 |
|
NIL |
16(Conservator for Non-sealed type Transformers) |
- |
1000 |
|
NIL |
20(Fittings) |
- |
1000 |
|
NIL |
6.8 (50%)(Total losses at 50 % load (Watts)) |
- |
2500 |
|
NIL |
7.8 (50%)(Total losses at 50 % load (Watts)) |
- |
2500 |
|
NIL |
8.8 (50%)(Total losses at 50 % load (Watts)) |
- |
2500 |
|
NIL |
6.8 (100%)(Total losses at 100 % load (Watts)) |
- |
2500 |
|
NIL |
7.8 (100%)(Total losses at 100 % load (Watts)) |
- |
2500 |
|
NIL |
8.8 (100%)(Total losses at 100 % load (Watts)) |
- |
2500 |
|
NIL |
21.5.1.3(Oil leakage test upto 200 KVA) |
- |
1000 |
|
NIL |
9.1a)(CRGO Electrical Steel) |
- |
200 |
|
NIL |
9.1 b)(Amorphous core material) |
- |
200 |
|
NIL |
9.1 c)(Copper/Aluminium conductor) |
- |
200 |
|
NIL |
9.1 d)(Kraft paper) |
- |
200 |
|
NIL |
9.1 e)(Press Board) |
- |
200 |
|
NIL |
9.1 f)(Mineral oil) |
- |
200 |
|
NIL |
10(Terminal Arrangement) |
- |
200 |
|
NIL |
15.2(Pressure and Vacuum Requirements) |
- |
200 |
|
NIL |
15.4(Gasket) |
- |
200 |
|
NIL |
19(Tolerances) |
- |
200 |
|
NIL |
18(Efficiency and regulation) |
- |
1000 |
|
NIL |
4(Service Conditions) |
- |
200 |
|
NIL |
5(General ) |
- |
200 |
|
NIL |
6.1(Rating) |
- |
200 |
|
NIL |
6.2(Rated frequency) |
- |
200 |
|
NIL |
6.3(Nominal system voltage) |
- |
200 |
|
NIL |
6.4(Basic Insulation level ) |
- |
200 |
|
NIL |
6.5(No-Load Voltage Ratios) |
- |
1000 |
|
NIL |
6.6(Winding connections and phase displacement) |
- |
2000 |
|
NIL |
6.7(Tapping Range and Tapping Method) |
- |
2000 |
|
NIL |
6.8(Losses and impedance values) |
- |
1000 |
|
NIL |
6.9(Permissible Flux Density and Over Fluxing ) |
- |
1000 |
|
NIL |
6.1(Limits of Temperature-rise) |
- |
2500 |
|
NIL |
7(Technical Parameters of three phase distribution trasnformers
higher than 200kva) |
- |
1000 |
|
NIL |
8(Technical Parameters of single phase distribution transformers
UP to and including 25 KVA ) |
- |
1000 |
|
NIL |
9(Standard Materials) |
- |
1000 |
|
NIL |
10(Terminal arrangment ) |
- |
1000 |
|
NIL |
11(Minimum Clearnaces air ) |
- |
1000 |
|
NIL |
12(Connectors ) |
- |
100 |
|
NIL |
13(Marking ) |
- |
100 |
|
NIL |
14(Mounting arrangement) |
- |
1000 |
|
NIL |
15(Trasnformer Tank ) |
- |
1000 |
|
NIL |
16(Conservator for Non-Sealed type Transformers) |
- |
200 |
|
NIL |
18(Efficiency and Regulation) |
- |
1000 |
|
NIL |
19(Tolerances) |
- |
200 |
|
NIL |
20(Fittings) |
- |
200 |
|
NIL |
21(General ) |
- |
200 |
|
NIL |
22(Information required with enquiry and order ) |
- |
200 |
|
NIL |
|
Complete
|
19 Jul, 2024 |
06 Jun, 2027 |
included w.e.f.29.10.2024
Exclusion
CL 17 ( ABILITY OF TRANSFORMERS TO WITHSTAND EXTERNAL SHORT CIRCUIT )
CL 21.3(c) (Short-circuit withstand test)
CL 21.4 b (Short-circuit withstand test IS 2026 (Part 5) (above 200 kVA))
CL 17 (Ability of transformers to withstand external Short circuit ) |
3 |
IS 16102 : Part 1 (2012) |
Self - Ballasted led lamps for general lighting services: Part 1 safety requirements |
Rating: Upto 35 Watt |
-
|
22000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
5(Marking) |
- |
400 |
|
20% Discount to BIS |
6(Interchangeability) |
- |
2000 |
|
20% Discount to BIS |
7(Protection against accidental contact with live parts) |
- |
5000 |
|
20% Discount to BIS |
8(Insulation Resistance and Electric Strength) |
- |
2000 |
|
20% Discount to BIS |
9(MECHANICAL STRENGTH) |
- |
1000 |
|
20% Discount to BIS |
10(cap temperature) |
- |
1000 |
|
20% Discount to BIS |
11(Resistance to Heat) |
- |
1800 |
|
20% Discount to BIS |
12(Resistance to Flame and Ignition) |
- |
2000 |
|
20% Discount to BIS |
13(Fault conditions) |
- |
5000 |
|
20% Discount to BIS |
14(Creepage distance and clearances) |
- |
1800 |
|
20% Discount to BIS |
|
Complete
|
19 Jul, 2024 |
06 Jun, 2027 |
For rated voltage up to 250V AC, 50 Hz and rated wattage up to 35 W.
• Restricted to Cap type B22d, E14 & E27 only.
Amendment No-3 including w.e.f. 06.03.2024 (rating upto 35 watt) |
4 |
IS 16246 (2015) |
Elastomer insulated cables with limited circuit integrity when affected by fire - Specification |
Size: 1-400 sqmm |
-
|
75000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Cl.4.1( Cables for Fixed Installation) |
- |
200 |
|
- |
Cl.5( INSULATION) |
- |
200 |
|
- |
Cl. 6.1( Glass Tape) |
- |
200 |
|
- |
Cl 6.2( Polyethylene Teraphthalate (PETP) or Polypropylene base Tape) |
- |
200 |
|
- |
Cl 6.4( Fire Barrier Tape) |
- |
200 |
|
- |
Cl 7(CENTRE AND FILLERS) |
- |
200 |
|
- |
Cl 7(CENTRE AND FILLERS) |
- |
200 |
|
- |
Cl 7(CENTRE AND FILLERS) |
- |
200 |
|
- |
Cl 7(CENTRE AND FILLERS) |
- |
200 |
|
- |
Cl 8( ARMOUR) |
- |
200 |
|
- |
Cl 9.1( Inner Sheath) |
- |
200 |
|
- |
Cl 9.2( Outer Sheath) |
- |
200 |
|
- |
Cl 10.1( CONDUCTORS) |
- |
200 |
|
- |
Cl 10.2( CONDUCTORS) |
- |
200 |
|
- |
Cl 11.1( INSULATION) |
- |
200 |
|
- |
Cl 11.2(Thickness of Insulation IS 10810 : Part 6) |
- |
1000 |
|
- |
Cl 12( CORE IDENTIFICATION) |
- |
200 |
|
- |
Cl 13( LAYING UP OF CORES) |
- |
200 |
|
- |
Cl 14.2( Thickness of Inner Sheath IS 10810 : Part 6) |
- |
1000 |
|
- |
Cl 15.1( ARMOURING) |
- |
200 |
|
- |
Cl 15.3.1( Type of Armour) |
- |
200 |
|
- |
Cl 15.3.2( Type of Armour) |
- |
200 |
|
- |
Cl 15.3.3( ARMOURING) |
- |
200 |
|
- |
Cl 15.3.3( ARMOURING) |
- |
200 |
|
- |
Cl 15.4.1( ARMOURING) |
- |
200 |
|
- |
Cl 15.4.2( ARMOURING) |
- |
200 |
|
- |
Cl 15.4.2( ARMOURING) |
- |
200 |
|
- |
Cl 15.4.2( ARMOURING) |
- |
200 |
|
- |
Cl 15.4.2( ARMOURING) |
- |
200 |
|
- |
Cl 15.4.2( ARMOURING) |
- |
200 |
|
- |
Cl 15.4.2( ARMOURING) |
- |
200 |
|
- |
Cl 15.4.2( ARMOURING) |
- |
200 |
|
- |
Cl 16.2( OUTER SHEATH) |
- |
200 |
|
- |
Cl 16.3( Thickness of Outer Sheath - Avg IS 10810 : Part 6) |
- |
1000 |
|
- |
Cl 16.3( Thickness of Outer Sheath - Minimum IS 10810 : Part 6) |
- |
1000 |
|
- |
Cl 17.2(Annealing test (for copper) IS 10810 : Part 1) |
- |
1000 |
|
- |
Cl 17.2(Conductor resistance test IS 10810 : Part 5) |
- |
2000 |
|
- |
Cl 17.1(Persulphate test (tinned copper conductor) IS 10810 : Part 4) |
- |
2000 |
|
- |
Cl 17.2(Tensile strength before ageing on insulation IS 10810 : Part 7) |
- |
2000 |
|
- |
Cl 17.2(elongation at break before ageing on insulation IS 10810 : Part 7) |
- |
2000 |
|
- |
Cl 17.2(Tensile strength after Ageing in air bomb IS 10810 : Part 56) |
- |
2000 |
|
- |
Cl 17.2(Elongation after Ageing in air bomb IS 10810 : Part 56) |
- |
2000 |
|
- |
Cl 17.2(Tensile strength variation) |
- |
2000 |
|
- |
Cl 17.2(Elongation Variation) |
- |
2000 |
|
- |
Cl 17.2(Hot set elongation on insulation IS 10810 : Part 30) |
- |
2000 |
|
- |
Cl 17.2(Permanent elongation (set) on insulation IS 10810 : Part 30) |
- |
2000 |
|
- |
Cl 17.1(Tensile strength before ageing on sheath IS 10810 : Part 7) |
- |
2000 |
|
- |
Cl 17.1(elongation at break before ageing on sheath IS 10810 : Part 7) |
- |
2000 |
|
- |
Cl 17.1(Hot set elongation test on sheath IS 10810 : Part 30) |
- |
2000 |
|
- |
Cl 17.1(Permanent elongation (set) test on sheath IS 10810 : Part 30) |
- |
2000 |
|
- |
Cl 17.1(Oxygen index test on sheath IS 10810 : Part 58) |
- |
2000 |
|
- |
Cl 17.1(Temperature index test on sheath IS 10810 : Part 64) |
- |
2000 |
|
- |
Cl 17.1(Acid gas generation on sheath IS 10810 : Part 39) |
- |
2000 |
|
- |
Cl 17.2(Insulation resistance test IS 10810 : Part 43) |
- |
2000 |
|
- |
Cl 17.1(Water absorption test (for insulation) IS 10810 : Part 28) |
- |
2000 |
|
- |
Cl 18.2(High Voltage Test IS 10810 : Part 45) |
- |
2000 |
|
- |
Cl 18.2(High Voltage Test IS 10810 : Part 45) |
- |
2000 |
|
- |
Cl 18.3 Annex B of IS 16246( Circuit Integrity Test Under Fire Condition) |
- |
10000 |
|
- |
Cl 18.3 Annex B of IS 16246( Circuit Integrity Test Under Fire Condition) |
- |
10000 |
|
- |
Cl 18.4.1( Flame Retardence Test on Single Cable IS 10810 : Part 61) |
- |
8000 |
|
- |
Cl 18.4.2(Flame Retardence Test on Bunched Cables IS 10810 : Part 63) |
- |
8000 |
|
- |
Cl 19.1( Manufacturer’s Identification) |
- |
200 |
|
- |
Cl 19.2( Voltage Identification) |
- |
200 |
|
- |
Cl 19.3( Cable Identification) |
- |
200 |
|
- |
Cl 19.4( Cable Code) |
- |
200 |
|
- |
|
Complete
|
19 Jul, 2024 |
06 Jun, 2027 |
Included w.e.f. 02.01.2024
Size: 1 to 400 sqmm |
5 |
IS 17505 : Part 1 (2021) |
Specification for Thermosetting Insulated Fire Survival Cables for Fixed Installation having Low Emission of Smoke and Corrosive Gases when Affected by Fire for Working Voltages upto and including 1100 Vac and 1500 Vdc |
Size: 1.5 to 630 sqmm |
-
|
160000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Cl. 7.3, Table 1 to 5 of IS 8130:2013 & IS:10810 (Part 5)-1984(Conductor Resistance Test) |
- |
3000 |
|
- |
Cl. 7.1.2 of IS 8130 : 2013 & IS:10810 (Part 1)-1984(Annealing Test (for copper)) |
- |
2500 |
|
- |
Cl. 7.1.1 of IS 8130:2013 & IS:10810 (Part 4)-1984(Persulphate Test for tinned copper) |
- |
2000 |
|
- |
IS 191:2007 & IS 440(Copper purity test) |
- |
5000 |
|
- |
Cl. 11,14,16, Table 4 and Table 6 of IS 17505 & IS:10810 (Part 6)-1984(Test for overall dimensions and thickness of insulation and sheath) |
- |
2000 |
|
- |
Table 7 of IS 17505-1:2021, IS 3975:1999 & IS:10810 (Part 36)-1984(Diameter of armour Wire) |
- |
2000 |
|
- |
Table 7 of IS 17505-1:2021, IS 3975:1999 & IS:10810 (Part 37)-1984(Tensile strength and elongation at break) |
- |
3000 |
|
- |
Table 7 of IS 17505-1:2021, IS 3975:1999 & IS:10810 (Part 38)-1984(Torsion Test on galvanised steel wire for armouring) |
- |
3000 |
|
- |
Table 7 of IS 17505-1:2021, IS 3975:1999 & IS:10810 (Part 39)-1984(Winding Test for Formed Wires) |
- |
3000 |
|
- |
Table 7 of IS 17505-1:2021, IS 3975:1999 & IS:10810 (Part 40)-1984(Uniformity of Zinc coating on Round Steel Wires and Formed Steel Wires (Strips)) |
- |
4000 |
|
- |
Table 7 of IS 17505-1:2021, IS 3975:1999 & IS:10810 (Part 41)-1984(Mass of Zinc coating on Round Steel Wires and Formed Steel Wires (Strips)) |
- |
4000 |
|
- |
Table 7 of IS 17505-1:2021, IS 3975:1999 & IS:10810 (Part 42)-1984(Resistivity test) |
- |
4000 |
|
- |
Table 1 and Table 2 of IS 17505 -1: 2021, IS:10810 (Part 7)-1984 & IS:10810 (Part 11)-1984(Tensile Strength and elongation at break before and after ageing.) |
- |
3000 |
|
- |
Cl 18.2 of IS 17505-1:2021 & IS:10810 (Part 45)-1984(High voltage test) |
- |
4000 |
|
- |
Table 1 of IS 17505-1 :2021 & IS:10810 (Part 43)-1984(Insulation Resistance) |
- |
5000 |
|
- |
Cl. 18.6 of IS 17505-1:2021 & IS:10810 (Part 58)-1998(Oxygen index) |
- |
4000 |
|
- |
Cl. 18.7 of IS 17505-1:2021 & IS:10810 (Part 64)-2003(Temperature Index) |
- |
4000 |
|
- |
Table-1 & Table-2 of IS 17505-1:2021 & IS:10810 (Part 11)-1984(Ageing in air oven.) |
- |
4000 |
|
- |
Specification for thermosetting insulated fire survival cables for fixed installation having low emission of smoke and corrosive gases when affected by fire for working voltages upto and including 1100 V A.C. and 1500 V D.C(Hot deformation) |
- |
4000 |
|
- |
Table-1 & Annex-F (F.1, F.2, F.3 F.4) of IS 17505-1 :2021(pH) |
- |
2000 |
|
- |
Table-1 & Annex-F (F.1, F.2, F.3 F.4) of IS 17505-1 :2021(Conductivity) |
- |
2000 |
|
- |
Table-1 & Annex-F (F.1, F.2, F.3 F.4) of IS 17505-1 :2021(HCl and HBr) |
- |
2000 |
|
- |
Table-1 & Annex-F (F.1, F.2, F.3 F.4) of IS 17505-1 :2021(Presence of Fluorine / Fluorine Content (if required)) |
- |
2000 |
|
- |
Table 1 of IS 17505-1: 2021 & IS:10810 (Part 21)-1984(Cold impact test) |
- |
4000 |
|
- |
Table 1 & 2 of IS 17505-1: 2021 & IS:10810 (Part 30)-1984(Hot set test) |
- |
4000 |
|
- |
Table 1 & 2 of IS 17505-1: 2021 & IS:10810 (Part 13)-1984(Ozone Resistance test) |
- |
4000 |
|
- |
Cl 18.5.1 of IS 17505-1 :2021 & IS:10810 (Part 61)-1988(Flame test on single cable) |
- |
4000 |
|
- |
Table 1 of IS 17505-1:2021 & IS:10810 (Part 12)-1984(Shrinkage test) |
- |
4000 |
|
- |
Cl 7 & Annex-F (F.1, F.2, F.3 F.4) of IS 17505-1 :2021(pH) |
- |
2000 |
|
- |
Cl 7 & Annex-F (F.1, F.2, F.3 F.4) of IS 17505-1 :2021(Conductivity) |
- |
2000 |
|
- |
Cl 7 & Annex-F (F.1, F.2, F.3 F.4) of IS 17505-1 :2021(HCl and HBr) |
- |
2000 |
|
- |
Cl 7 & Annex-F (F.1, F.2, F.3 F.4) of IS 17505-1 :2021(Presence of Fluorine / Fluorine Content (if required)) |
- |
2000 |
|
- |
Tabel 1 and 2 of IS 17505-1:2021 & IS:10810 (Part 7)-1984(Tensile strength and elongation at break.) |
- |
4000 |
|
- |
Tabel 1 and 2 of IS 17505-1:2021 & IS:10810 (Part 11)-1984(Ageing in air oven.) |
- |
4000 |
|
- |
Cl 18.6 of IS 17505-1: 2021 & IS:10810 (Part 58)-1998(Oxygen Index.) |
- |
4000 |
|
- |
Cl 18.8 of IS 17505-1:2021 & IS:10810 (Part 64)-2003(Temperature Index) |
- |
4000 |
|
- |
Table 1 & 2 of IS 17505-1: 2021 & IS:10810 (Part 13)-1984(Ozone resistance test) |
- |
4000 |
|
- |
Table 2 of IS 17505-1:2021 & IS:10810 (Part 15)-1984(Hot deformation) |
- |
4000 |
|
- |
Cl 7 & Annex-F (F.1, F.2, F.3 F.4) of IS 17505-1 :2021(pH) |
- |
2000 |
|
- |
Cl 7 & Annex-F (F.1, F.2, F.3 F.4) of IS 17505-1 :2021(Conductivity) |
- |
2000 |
|
- |
Cl 7 & Annex-F (F.1, F.2, F.3 F.4) of IS 17505-1 :2021(HCl and HBr) |
- |
2000 |
|
- |
Cl 7 & Annex-F (F.1, F.2, F.3 F.4) of IS 17505-1 :2021(Presence of Fluorine / Fluorine Content (if required)) |
- |
2000 |
|
- |
Table 1 of IS 17505-1:2021 & IS:10810 (Part 12)-1984(Shrinkage test) |
- |
4000 |
|
- |
Cl 18.2of IS 17505-1:2021 & IS:10810 (Part 45)-1984.(High Voltage test.) |
- |
4000 |
|
- |
Cl 18.5of IS 17505-1:2021 & IS:10810 (Part 53)-1984(Flammability Test) |
- |
4000 |
|
- |
Table-2 of IS 17505-1:2021 & IS:10810 (Part 20)-1984(Cold bend test) |
- |
4000 |
|
- |
Table-2 of IS 17505-1:2021 & IS:10810 (Part 21)-1984(Cold impact test) |
- |
4000 |
|
- |
Cl 18.5 of IS 17505-1:2021 & IS:10810 (Part 61)-1988(Flammability Test) |
- |
4000 |
|
- |
Cl 18.9 of IS 17505-1:2021(Water immersion test ( effect of water on sheath of cable)) |
- |
4000 |
|
- |
Cl 18.8 of IS 17505-1:2021& IS:10810 (Part 63)-1993(Smoke density test) |
- |
4000 |
|
- |
Cl. 3.5, 18.4 & Annex-E of IS 17505-1:2021(Circuit integrity test under fire) |
- |
4000 |
|
- |
Cl. 17.1 Table 9 (iv) e(Heat Shock) |
- |
4000 |
|
- |
Cl. 17.1 Table 9 (iv) h(Water absorption (Gravimetric)) |
- |
4000 |
|
- |
Cl. 17.1 Table 9 (vii) b(Flame test on bunched cable) |
- |
4000 |
|
- |
Cl. 17.1 Table 9 (ix)(Abrasion resistance test) |
- |
4000 |
|
- |
|
Complete
|
19 Jul, 2024 |
06 Jun, 2027 |
Included w.e.f. 20.12.2023. Size: 1.5 to 630 sqmm. |
6 |
IS 9968 : Part 2 (2002) |
Specification for elastomer - Insulated cables: Part 2 for working voltages from 3.3 kV up to and including 33 kV (First Revision) |
Size: 16 to 630 sqmm |
-
|
190000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
4.1(CONDUCTORS: Cables for Fixed Installation) |
- |
200 |
|
- |
4.2(CONDUCTORS:Flexible Cables) |
- |
200 |
|
- |
5(INSULATION) |
- |
200 |
|
- |
6(SEMICONDUCTING COMPOUND) |
- |
200 |
|
- |
7.1(Proofed Tape) |
- |
200 |
|
- |
7.1(Proofed Tape: Thickness) |
- |
200 |
|
- |
7.2(Polyethylene Terephthalate ( P E T P ) or
Polypropylene Base Tape : Thickness) |
- |
200 |
|
- |
7.3(Tape ) |
- |
200 |
|
- |
8(SCREENING) |
- |
200 |
|
- |
9(CENTRE AND FILLERS) |
- |
200 |
|
- |
10(ARMOUR) |
- |
200 |
|
- |
11.1(Inner Sheath) |
- |
200 |
|
- |
11.2(Outer Sheath) |
- |
200 |
|
- |
12.1(Tapes) |
- |
200 |
|
- |
12.2(Cords and Yarns) |
- |
200 |
|
- |
13.1 & 13.2(CONSTRUCTION:CONDUCTORS-Cables for Fixed Installations/Flexible Cables) |
- |
200 |
|
- |
13.3(Earthing Conductor) |
- |
200 |
|
- |
13.3.1(Earthing Conductor) |
- |
200 |
|
- |
13.4(Separator Tape) |
- |
200 |
|
- |
14(CONDUCTOR SCREENING) |
- |
200 |
|
- |
15.1(INSULATION : Application) |
- |
200 |
|
- |
15.2(Thickness of Insulation) |
- |
1000 |
|
- |
15.3(Tolerance on Thickness of Insulation) |
- |
1000 |
|
- |
16.1(INSULATION SCREENING : Application) |
- |
200 |
|
- |
16.2(INSULATION SCREENING : Parts ) |
- |
200 |
|
- |
16.3(INSULATION SCREENING : Non Metallic Parts ) |
- |
200 |
|
- |
16.4(INSULATION SCREENING : Metallic Parts ) |
- |
200 |
|
- |
17(CORE IDENTIFICATION) |
- |
200 |
|
- |
17(CORE IDENTIFICATION: Unscreed cable ) |
- |
200 |
|
- |
18.1(LAYING UP OF CORES) |
- |
200 |
|
- |
18.2(LAYING UP OF CORES : Flexible cable) |
- |
200 |
|
- |
18.3(LAYING UP OF CORES : Binder Tape) |
- |
200 |
|
- |
19.1(Inner Sheath : Application) |
- |
200 |
|
- |
19.2(Thickness of Inner Sheath) |
- |
1000 |
|
- |
19.3(Inner Sheath : proofed tape) |
- |
200 |
|
- |
20.1(ARMOURING: Application) |
- |
200 |
|
- |
20.2(Type of Armour) |
- |
200 |
|
- |
20.2 1.2(Direction of lay of armour) |
- |
200 |
|
- |
20.2 1.3(Joint in armour) |
- |
200 |
|
- |
20.2.2(Filling Factot ) |
- |
200 |
|
- |
20.2.2(Diameter of braiding) |
- |
200 |
|
- |
20.2.2.1(Braiding material) |
- |
200 |
|
- |
20.3(Substitution of the galvanized steel wires/formed) |
- |
200 |
|
- |
21.1(OUTER SHEATH) |
- |
200 |
|
- |
21.2(Coulor of Outer sheath) |
- |
200 |
|
- |
21.3(Thickness of Outer Sheat: Average) |
- |
1000 |
|
- |
21.3(Thickness of Outer Sheat: Minimum) |
- |
1000 |
|
- |
22.1 a)1)(Annealing test
(for copper) - IS 10810: Part 1) |
- |
500 |
|
- |
22.1 a)2)(Tensile test
(for aluminium) -IS 10810: Part 2) |
- |
1000 |
|
- |
22.1 a)3)(Wrapping Test
(for aluminium) - IS 10810: Part 3) |
- |
1000 |
|
- |
22.1 a)4)(Conductor resistance
test) |
- |
1000 |
|
- |
22.1 a)5)(Persulphate test
(tinned copper
conductor)- IS 10810: Part 4) |
- |
1000 |
|
- |
22.1 b)1)(Test for Galvanized Steel
Wires/Formed Wires
1) Dimensions -IS 10810: Part 36) |
- |
1000 |
|
- |
22.1 b)2)i)(Test for Galvanized Steel
Wires/Formed Wires
2) Tensile Strentgh -IS 10810: Part 37) |
- |
1000 |
|
- |
22.1 b)2)ii)(Test for Galvanized Steel
Wires/Formed Wires
2) Elongation at break -IS 10810: Part 37) |
- |
1000 |
|
- |
22.1 b)2)iii)(Test for Galvanized Steel
Wires/Formed Wires
3) Torsion (for round
wires only) -IS 10810: Part 38) |
- |
1000 |
|
- |
22.1 b)2)iv)(Test for Galvanized Steel
Wires/Formed Wires
4) Winding (for strips
only) -IS 10810: Part 39) |
- |
1000 |
|
- |
22.1 b)2)v)(Test for Galvanized Steel
Wires/Formed Wires
5) Zinc coating : Uniformity-IS 10810: Part 40) |
- |
1000 |
|
- |
22.1 b)2)vi)(Test for Galvanized Steel
Wires/Formed Wires
5) Zinc coating : Mass -IS 10810: Part 41) |
- |
1000 |
|
- |
22.1 b)2) vii) (Resistivity - IS 10810: Part 42) |
- |
1000 |
|
- |
22.1 c)2)(Physical Tests for
Insulation : Tensile Strenth - IS 10810: Part 7) |
- |
1000 |
|
- |
22.1 c)2)(Physical Tests for
Insulation : Elongation - IS 10810: Part 7) |
- |
1000 |
|
- |
22.1 c)2)(Physical Tests for
Sheath : Tensile Strenth - IS 10810: Part 7) |
- |
1000 |
|
- |
22.1 c)2)(Physical Tests for
Sheath : Elongation - IS 10810: Part 7) |
- |
1000 |
|
- |
22.1 c)3)(Physical Tests for
Insulation ( Ageing in air oven): Tensile Strenth - IS 10810: Part 11) |
- |
1000 |
|
- |
22.1 c)3)(Physical Tests for
Insulation ( Ageing in air oven): Tensile Strenth Variation - IS 10810: Part 12) |
- |
1000 |
|
- |
22.1 c)3)(Physical Tests for
Insulation( Ageing in air oven) : Elongation - IS 10810: Part 11) |
- |
1000 |
|
- |
22.1 c)3)(Physical Tests for
Insulation( Ageing in air oven) : Elongation variation - IS 10810: Part 12) |
- |
1000 |
|
- |
22.1 c)3)(Physical Tests for
Sheath( Ageing in air oven) : Tensile Strenth - IS 10810: Part 11) |
- |
1000 |
|
- |
22.1 c)3)(Physical Tests for
Sheath( Ageing in air oven) : Tensile Strenth variation - IS 10810: Part 12) |
- |
1000 |
|
- |
22.1 c)3)(Physical Tests for
Sheath ( Ageing in air oven): Elongation - IS 10810: Part 11) |
- |
1000 |
|
- |
22.1 c)3)(Physical Tests for
Sheath ( Ageing in air oven): Elongation variation - IS 10810: Part 12) |
- |
1000 |
|
- |
22.1 c)4)(Physical Tests for
Insulation ( Ageing in air bomb): Tensile Strenth variation - IS 10810: Part 56) |
- |
1000 |
|
- |
22.1 c)4)(Physical Tests for
Insulation( Ageing in air bomb) : Elongation variation - IS 10810: Part 56) |
- |
1000 |
|
- |
22.1 c)4)(Physical Tests for
Sheath(Ageing in air bomb) : Tensile Strenth variation - IS 10810: Part 56) |
- |
1000 |
|
- |
22.1 c)4)(Physical Tests for
Sheath ( Ageing in air bomb): Elongation variation - IS 10810: Part 56) |
- |
1000 |
|
- |
22.1 c)5)(Physical Tests for
Insulation :Hot set Elongation - IS 10810: Part 30) |
- |
1500 |
|
- |
22.1 c)5)(Physical Tests for
Insulation :Permanent set - IS 10810: Part 30) |
- |
1500 |
|
- |
22.1 c)5)(Physical Tests for
Sheath :Hot set Elongation - IS 10810: Part 30) |
- |
1500 |
|
- |
22.1 c)5)(Physical Tests for
Sheath :Permanent set - IS 10810: Part 30) |
- |
1500 |
|
- |
22.1 c)6)(Physical Tests for
Sheath(Oil resistance test) : Tensile Strenth Variation - IS 10810: Part 31) |
- |
1500 |
|
- |
22.1 c)6)(Physical Tests for
Sheath ( Oil resistance test): Elongation Variation - IS 10810: Part 31) |
- |
1500 |
|
- |
22.1 c)7)(Tear Resistance test - IS 10810: Part 17) |
- |
1500 |
|
- |
22.1 c)8)(Shrinkage : Insulation - IS 10810: Part 12) |
- |
1500 |
|
- |
22.1 c)8)(Shrinkage test- Crack observed : Insulation - IS 10810: Part 13) |
- |
1500 |
|
- |
22.1 c)8)(Shrinkage test : Sheath - IS 10810: Part 12) |
- |
1500 |
|
- |
22.1 c)8)(Shrinkage test - Crack oberved : Sheath - IS 10810: Part 13) |
- |
1500 |
|
- |
22.1 c)9)(Hot deformation test : Insulation - IS 10810: Part 15) |
- |
1500 |
|
- |
22.1 c)9)(Hot deformation test : Sheath - IS 10810: Part 15) |
- |
1500 |
|
- |
22.1 c)10)(Loss of mass in air
oven : Insulation - IS 10810: Part 10) |
- |
1500 |
|
- |
22.1 c)10)(Loss of mass in air
oven : Sheath - IS 10810: Part 10) |
- |
1500 |
|
- |
22.1 c)11)(Heat shock : Insulation - IS 10810: Part 14) |
- |
1500 |
|
- |
22.1 c)11)(Heat shock : Sheath - IS 10810: Part 14) |
- |
1500 |
|
- |
22.1 c)12)(Thermal stability : Insulation - IS 10810: Part 60) |
- |
1500 |
|
- |
22.1 c)12)(Thermal stability : Sheath - IS 10810: Part 60) |
- |
1500 |
|
- |
22.1 d)(Insulation Resistance Test: Volume resistivity ) |
- |
1500 |
|
- |
22.1 d)(Insulation Resistance Test: Insulation resistance constant ) |
- |
1500 |
|
- |
22.1 e)(Partial Discharge Test) |
- |
35000 |
|
- |
22.1 f)(Bending Test Followed by
Partial Discharge Test) |
- |
25000 |
|
- |
22.1 g)(Dielectric Power Factor
Test
1) As a function of Voltage) |
- |
1000 |
|
- |
22.1 g)(Dielectric Power Factor
Test
1) As a function of
temperature) |
- |
1000 |
|
- |
22.1 h)(Heating Cycle Test) |
- |
25000 |
|
- |
22.1 j)(Impulse Withstand Test) |
- |
25000 |
|
- |
22.1 k)(High Voltage Test
for Four Hours) |
- |
25000 |
|
- |
22.1 m)(Water Absorption Test - IS 10810: Part 28) |
- |
1500 |
|
- |
22.1 n)(Flammability) |
- |
5000 |
|
- |
24.1(Manufacturer's Identification) |
- |
200 |
|
- |
24.2(Voltage Identification) |
- |
200 |
|
- |
24.3(Cable Code) |
- |
200 |
|
- |
25.2.1(Marking on drum ) |
- |
200 |
|
- |
25.2.2(BIS Certification Marking) |
- |
200 |
|
- |
|
Complete
|
19 Jul, 2024 |
06 Jun, 2027 |
Included w.e.f. 20.12.2023. Size: 16 to 630 sqmm |
7 |
IS 1554 : Part 2 (1988) |
Specification for pvc insulated (Heavy Duty) electric cables: Part 2 for working voltages from 3.3 kV up to and including 11 kV (Second Revision) |
Size: 25 to 630 sqmm |
-
|
190000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
3.1(CONDUCTOR) |
- |
200 |
|
- |
3.1.1(CONDUCTOR) |
- |
200 |
|
- |
4.1(INSULATION) |
- |
200 |
|
- |
5.1(SCREENING) |
- |
200 |
|
- |
6.1(FILLERS AND INNER SHEATH) |
- |
500 |
|
- |
6.2(FILLERS AND INNER SHEATH) |
- |
500 |
|
- |
7.1(ARMOURING) |
- |
200 |
|
- |
7.2(ARMOURING) |
- |
200 |
|
- |
8.1(OUTER SHEATH) |
- |
200 |
|
- |
9.1(CONDUCTOR) |
- |
200 |
|
- |
9.2(CONDUCTOR) |
- |
200 |
|
- |
10.1(CONDUCTOR SCREENING) |
- |
200 |
|
- |
11.1(INSULATION) |
- |
200 |
|
- |
11.2(INSULATION : Thickness of Insulation) |
- |
200 |
|
- |
11.3(INSULATION : Tolerance on Thickness of Insulation) |
- |
200 |
|
- |
11.4(INSULATION : Application of Insulation) |
- |
200 |
|
- |
12.1(INSULATION SCREENING) |
- |
200 |
|
- |
12.2(INSULATION SCREENING) |
- |
200 |
|
- |
12.3(INSULATION SCREENING) |
- |
200 |
|
- |
12.4(INSULATION SCREENING) |
- |
200 |
|
- |
13.1(CORE IDENTIFICATION) |
- |
200 |
|
- |
13.1.1(CORE IDENTIFICATION) |
- |
200 |
|
- |
14.1(LAYING UP OF CORES) |
- |
200 |
|
- |
15.1(INNER SHEATH (COMMON COVERING)) |
- |
200 |
|
- |
15.2(INNER SHEATH (COMMON COVERING)) |
- |
200 |
|
- |
15.3(INNER SHEATH (COMMON COVERING)) |
- |
200 |
|
- |
15.4(INNER SHEATH (COMMON COVERING) : Thickness of Inner Sheath) |
- |
200 |
|
- |
15.4.1(INNER SHEATH (COMMON COVERING) : Thickness of Inner Sheath) |
- |
200 |
|
- |
16.1.1(ARMOURING : Application) |
- |
200 |
|
- |
16.1.2(ARMOURING : Application) |
- |
200 |
|
- |
16.1.3(ARMOURING : Direction of lay ) |
- |
200 |
|
- |
16.1.4(ARMOURING : Application) |
- |
200 |
|
- |
16.2.1(ARMOURING : Type of Armour) |
- |
200 |
|
- |
16.2.2(ARMOURING : Type of Armour) |
- |
200 |
|
- |
16.3(Armouring : Dimensions -Wire Diameter) |
- |
200 |
|
- |
16.3(Armouring : Dimensions -Formed wire ) |
- |
200 |
|
- |
16.4(ARMOURING : Joints) |
- |
200 |
|
- |
16.5(ARMOURING : Resistance) |
- |
200 |
|
- |
13.6 a)(ARMOURING: Tensile Strength) |
- |
1000 |
|
- |
13.6 b)(ARMOURING: Elongation ) |
- |
1000 |
|
- |
13.6 c)(ARMOURING: Torsion Test (For round wire ) ) |
- |
1000 |
|
- |
13.6 d)(ARMOURING: Winding Test(For formed wire)) |
- |
1000 |
|
- |
13.6 e)(ARMOURING: Uniformity of zinc coating) |
- |
1000 |
|
- |
13.6 f)(ARMOURING: Mass of zinc coating ) |
- |
1000 |
|
- |
13.6 g)(ARMOURING: Resistivity) |
- |
1000 |
|
- |
17.1(OUTER SHEATH) |
- |
200 |
|
- |
17.2(OUTER SHEATH : colour ) |
- |
200 |
|
- |
17.3.1(Thickness of Outer Sheath : Unarmoured Cables) |
- |
1000 |
|
- |
17.3.2(Thickness of Outer Sheath : Armoured Cables) |
- |
1000 |
|
- |
18.1 a) 1)(Tests on Conductor : Annealing test (for copper)) |
- |
500 |
|
- |
18.1 a) 2)(Tensile test (for aluminium) - Before stranding ) |
- |
1000 |
|
- |
18.1 a) 2)(Tensile test (for aluminium) - After stranding ) |
- |
1000 |
|
- |
18.1 a) 3)(Tests on Conductor : Wrapping test ( for aluminium)) |
- |
1000 |
|
- |
18.1 a)4)(Tests on conductor : Conductor resistance test - Main conductor ) |
- |
1000 |
|
- |
18.1 a)4)(Resistance test - Neutral conductor ) |
- |
1000 |
|
- |
18.1 d) 1)(Phyaical tests for insulation : Tensile Test) |
- |
1000 |
|
- |
18.1 d) 1)(Phyaical tests for insulation : Elongation ) |
- |
1000 |
|
- |
18.1 d) 1)(Physical tests for sheath : Tensile stregth ) |
- |
1000 |
|
- |
18.1 d) 1)(Physical tests for sheath : Elongation ) |
- |
1000 |
|
- |
18.1 d) 2)(Phyaical tests for insulation- Ageing in air Oven : Tensile Test) |
- |
1000 |
|
- |
18.1 d) 2)(Phyaical tests for insulation - Ageing in air oven : Elongation ) |
- |
1000 |
|
- |
18.1 d) 2)(Phyaical tests for insulation - Ageing in air Oven : Tensile Variation ) |
- |
1000 |
|
- |
18.1 d) 2)(Phyaical tests for insulation- Ageing in air oven : Elongation Variation ) |
- |
1000 |
|
- |
18.1 d) 2)(Physical tests for outer sheath- Ageing in air oven : Tensile stregth ) |
- |
1000 |
|
- |
18.1 d) 2)(Physical tests for outer sheath -Ageing in air oven : Elongation ) |
- |
1000 |
|
- |
18.1 d) 2)(Physical tests for outer sheath- Ageing in air oven : Tensile stregth Variation ) |
- |
1000 |
|
- |
18.1 d) 2)(Physical tests for outer sheath -Ageing in air oven : Elongation Variation ) |
- |
1000 |
|
- |
18.1 d) 3)(Phyaical tests for insulation : Shrinkage ) |
- |
1500 |
|
- |
18.1 d) 3)(Phyaical tests for insulation : Shrinkage - Crack observed ) |
- |
1500 |
|
- |
18.1 d) 3)(Phyaical tests for Sheath : Shrinkage ) |
- |
1500 |
|
- |
18.1 d) 3)(Phyaical tests for Sheath : Shrinkage - Crack observed ) |
- |
1500 |
|
- |
18.1 d) 4)(Hot deformation : Insulation ) |
- |
1500 |
|
- |
18.1 d) 4)(Hot deformation : Sheath ) |
- |
1500 |
|
- |
18.1 d) 5)( Loss of mass in air oven- Insulation ) |
- |
1500 |
|
- |
18.1 d) 5)( Loss of mass in air oven- sheath ) |
- |
1500 |
|
- |
18.1 d) 6)(Heat shock test- Insulation ) |
- |
1500 |
|
- |
18.1 d) 6)(Heat shock test- sheath ) |
- |
1500 |
|
- |
18.1 d) 7)(Thermal stability- insulation ) |
- |
1500 |
|
- |
18.1 d) 7)(Thermal stability- Sheath ) |
- |
1500 |
|
- |
18.1 d) 8)(Water absorption (gravimetric)(for insulation, where applicable)) |
- |
1500 |
|
- |
18.1 e)(Insulation resistance test : Volume Resistivity ) |
- |
1500 |
|
- |
18.1 e)(Insulation resistance test : IR Constant ) |
- |
1500 |
|
- |
19.2(Partial discharge test) |
- |
35000 |
|
- |
19.3(Bending test) |
- |
1000 |
|
- |
19.4(Dielectric power factor test) |
- |
1000 |
|
- |
19.4(Dielectric power factor test) |
- |
1000 |
|
- |
19.5(Heating cycle test) |
- |
25000 |
|
- |
19.6(Impulse withstand test) |
- |
25000 |
|
- |
19.7(High voltage test) |
- |
25000 |
|
- |
19.8(Flammability test) |
- |
5000 |
|
- |
19.9(Oxygen Index Test) |
- |
5000 |
|
- |
19.10(Flame Retardance Test on Single Cables) |
- |
5000 |
|
- |
19.11(Flame Retardance Test on Bunched Cables) |
- |
8000 |
|
- |
19.13(Test for Halogen Acid Gas Evolution) |
- |
8000 |
|
- |
19.14(Temperature Index) |
- |
5000 |
|
- |
18.4(Optional Test : Cold Impact ) |
- |
3000 |
|
- |
20.1(IDENTIFICATION : Manufacturer's Identification) |
- |
200 |
|
- |
20.2(IDENTIFICATION : Cable Identification) |
- |
200 |
|
- |
20.3(IDENTIFICATION : Cable Code) |
- |
200 |
|
- |
5.1.1(Non-magnetic Metallic Tape for SingleCore Unscreened and Unarmoured Cables) |
- |
200 |
|
- |
|
Complete
|
19 Jul, 2024 |
06 Jun, 2027 |
Included w.e.f. 20.12.2023. Size: 25 to 630 sqmm |
8 |
IS 7098 : Part 3 (1993) |
Cross - Linked polyethylene insulated thermoplastic sheathed cables - Specification: Part 3 for working voltages from 66 kV up to and including 220 kV |
Size: 95-630 sqmm |
-
|
550000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
4.1(CONDUCTOR) |
- |
1000 |
|
- |
5(INSULATION) |
- |
1000 |
|
- |
6(SCREENING) |
- |
1000 |
|
- |
7.1(MOISTURE BARRIER : Laminated Tape) |
- |
1000 |
|
- |
7.2(MOISTURE BARRIER : Lead Alloy Sheath) |
- |
1000 |
|
- |
7.3(MOISTURE BARRIER : Water Blocking Tape/Powder) |
- |
1000 |
|
- |
8.1(INNER SHEATH) |
- |
1000 |
|
- |
8.2(INNER SHEATH) |
- |
1000 |
|
- |
8.3(INNER SHEATH) |
- |
1000 |
|
- |
9.1(ARMOUR) |
- |
1000 |
|
- |
9.2(ARMOUR) |
- |
1000 |
|
- |
10.1(OUTER SHEATH) |
- |
1000 |
|
- |
10.2(OUTER SHEATH) |
- |
1000 |
|
- |
11.1(CONDUCTOR) |
- |
1000 |
|
- |
11.2(CONDUCTOR) |
- |
1000 |
|
- |
12.1(CONDUCTOR SCREENING ) |
- |
1000 |
|
- |
12.2(CONDUCTOR SCREENING ) |
- |
1000 |
|
- |
13.1(INSULATION) |
- |
1000 |
|
- |
13.2(INSULATION) |
- |
1000 |
|
- |
14.1(INSULATION SCREENING) |
- |
1000 |
|
- |
14.2.1(INSULATION SCREENING : Non-metallic Part) |
- |
1000 |
|
- |
14.2.2(INSULATION SCREENING : Non-metallic Part) |
- |
1000 |
|
- |
14.2.3(INSULATION SCREENING : Non-metallic Part) |
- |
1000 |
|
- |
14.3.1(INSULATION SCREENING : Metallic Part) |
- |
1000 |
|
- |
14.3.2(INSULATION SCREENING : Metallic Part) |
- |
1000 |
|
- |
14.3.3(INSULATION SCREENING : Metallic Part) |
- |
1000 |
|
- |
15.1(MOISTURE BARRIER) |
- |
1000 |
|
- |
15.2.1(Metallic Sheath) |
- |
1000 |
|
- |
15.2.2(Metallic Sheath) |
- |
1000 |
|
- |
16.1(INNER SHEATH) |
- |
1000 |
|
- |
16.2(INNER SHEATH) |
- |
1000 |
|
- |
17.1(ARMOUR) |
- |
1000 |
|
- |
17.2(ARMOUR) |
- |
1000 |
|
- |
17.3(ARMOUR) |
- |
1000 |
|
- |
17.4(ARMOUR) |
- |
1000 |
|
- |
17.5(ARMOUR) |
- |
1000 |
|
- |
18.1(OUTER SHEATH) |
- |
1000 |
|
- |
18.2(outer sheath colour) |
- |
1000 |
|
- |
18.3.1(Thickness of Outer Sheath : Unarmoured Cables) |
- |
2500 |
|
- |
18.3.1(Thickness of Outer Sheath : armoured Cables) |
- |
2500 |
|
- |
19.1 A) I)(Tests on conductor : Annealing test ( for copper )) |
- |
2500 |
|
- |
19.1 A) II)(Tests on conductor : Resistance test) |
- |
5000 |
|
- |
19.1 b) I)(Test for thickness and dimensions of insulation) |
- |
5000 |
|
- |
19.1 b) II)(Tensile strength and elongation at break) |
- |
5000 |
|
- |
19.1 b) III)(Thermal ageing in air oven) |
- |
5000 |
|
- |
19.1 b) IV)(Hot set test) |
- |
5000 |
|
- |
19.1 b) V)(Shrinkage test) |
- |
5000 |
|
- |
20.3(Test for concentric metallic screen : Test for concentric copper wire) |
- |
5000 |
|
- |
20.4(Test for concentric copper tape) |
- |
5000 |
|
- |
20.5(Thickness of metallic sheath) |
- |
5000 |
|
- |
20.6(Tests for armouring material : Dimensions) |
- |
5000 |
|
- |
19.1 f) II)(Tests for armouring material : Tensile strength and elongation at break) |
- |
5000 |
|
- |
Table 9, (Measurement of thickness) |
- |
5000 |
|
- |
19.1 g)2) i)(PVC sheath : Tensile strength and elongation at break) |
- |
5000 |
|
- |
19.1 g)2) iii)(PVC sheath : Loss of mass) |
- |
5000 |
|
- |
19.1 g)2) v)(PVC sheath : Hot deformation test) |
- |
5000 |
|
- |
19.1 g)2) vi)(PVC sheath : Shrinkage test) |
- |
5000 |
|
- |
19.1 g)2) vii)(PVC sheath : Thermal stability) |
- |
5000 |
|
- |
19.1 g)3) ii)(PE sheath : Tensile strength and elongation at break before and after ageing) |
- |
5000 |
|
- |
19.1 g)3) iii)(PE sheath : Hot-detormation) |
- |
5000 |
|
- |
20.7(Flammabihty test ( for PVC outer
sheathed cables only )) |
- |
8000 |
|
- |
20.8.3(Water tightness test) |
- |
8000 |
|
- |
20.9.1(Thermal ageing on complete cable sample) |
- |
8000 |
|
- |
19.1 k) ii)(Tensile strength and elongation at breakfor insulation and outer sheath) |
- |
5000 |
|
- |
20.2(Resistivity test for semi-conducting layer) |
- |
5000 |
|
- |
20.11.1(Bending test followed by P D test) |
- |
70000 |
|
- |
20.12, 20.18(Dielectric power factor and capacitance measurement at ambient temperature) |
- |
5000 |
|
- |
20.13(Dielectric power factor measurement at elevated temperature) |
- |
5000 |
|
- |
20.14.1(Load cycle test followed by P.D measurement) |
- |
70000 |
|
- |
20.15(Impulse Voltage Test Followed by High Voltage Test) |
- |
50000 |
|
- |
19.5(Check on Insulation Thickness Before the Electrical Type Tests) |
- |
5000 |
|
- |
20.16.1(Test for Dimensions of Insulation : Insulation Thickness) |
- |
5000 |
|
- |
20.16.2(Test for Dimensions of Insulation : Test for Eccentricity) |
- |
5000 |
|
- |
20.16.3(Test for Dimensions of Insulation : Test for Ovality) |
- |
5000 |
|
- |
20.17(High Voltage Test ( as Routine and
Acceptance Tests ) ) |
- |
50000 |
|
- |
20.18(Measurement of Capacitance) |
- |
5000 |
|
- |
4.1(CONDUCTOR) |
- |
1000 |
|
- |
5(INSULATION) |
- |
1000 |
|
- |
6(SCREENING) |
- |
1000 |
|
- |
7.1(MOISTURE BARRIER : Laminated Tape) |
- |
1000 |
|
- |
7.2(MOISTURE BARRIER : Lead Alloy Sheath) |
- |
1000 |
|
- |
7.3(MOISTURE BARRIER : Water Blocking Tape/Powder) |
- |
1000 |
|
- |
8.1(INNER SHEATH) |
- |
1000 |
|
- |
8.2(INNER SHEATH) |
- |
1000 |
|
- |
8.3(INNER SHEATH) |
- |
1000 |
|
- |
9.1(ARMOUR) |
- |
1000 |
|
- |
9.2(ARMOUR) |
- |
1000 |
|
- |
10.1(OUTER SHEATH) |
- |
1000 |
|
- |
10.2(OUTER SHEATH) |
- |
1000 |
|
- |
11.1(CONDUCTOR) |
- |
1000 |
|
- |
11.2(CONDUCTOR) |
- |
1000 |
|
- |
12.1(CONDUCTOR SCREENING ) |
- |
1000 |
|
- |
12.2(CONDUCTOR SCREENING ) |
- |
1000 |
|
- |
13.1(INSULATION) |
- |
1000 |
|
- |
13.2(INSULATION) |
- |
1000 |
|
- |
14.1(INSULATION SCREENING) |
- |
1000 |
|
- |
14.2.1(INSULATION SCREENING : Non-metallic Part) |
- |
1000 |
|
- |
14.2.2(INSULATION SCREENING : Non-metallic Part) |
- |
1000 |
|
- |
14.2.3(INSULATION SCREENING : Non-metallic Part) |
- |
1000 |
|
- |
14.3.1(INSULATION SCREENING : Metallic Part) |
- |
1000 |
|
- |
14.3.2(INSULATION SCREENING : Metallic Part) |
- |
1000 |
|
- |
14.3.3(INSULATION SCREENING : Metallic Part) |
- |
1000 |
|
- |
15.1(MOISTURE BARRIER) |
- |
1000 |
|
- |
15.2.1(Metallic Sheath) |
- |
1000 |
|
- |
15.2.2(Metallic Sheath) |
- |
1000 |
|
- |
16.1(INNER SHEATH) |
- |
1000 |
|
- |
16.2(INNER SHEATH) |
- |
1000 |
|
- |
17.1(ARMOUR) |
- |
1000 |
|
- |
17.2(ARMOUR) |
- |
1000 |
|
- |
17.3(ARMOUR) |
- |
1000 |
|
- |
17.4(ARMOUR) |
- |
1000 |
|
- |
17.5(ARMOUR) |
- |
1000 |
|
- |
18.1(OUTER SHEATH) |
- |
1000 |
|
- |
18.2(outer sheath colour) |
- |
1000 |
|
- |
18.3.1(Thickness of Outer Sheath : Unarmoured Cables) |
- |
2500 |
|
- |
18.3.1(Thickness of Outer Sheath : armoured Cables) |
- |
2500 |
|
- |
19.1 A) I)(Tests on conductor : Annealing test ( for copper )) |
- |
2500 |
|
- |
19.1 A) II)(Tests on conductor : Resistance test) |
- |
5000 |
|
- |
19.1 b) I)(Test for thickness and dimensions of insulation) |
- |
5000 |
|
- |
19.1 b) II)(Tensile strength and elongation at break) |
- |
5000 |
|
- |
19.1 b) III)(Thermal ageing in air oven) |
- |
5000 |
|
- |
19.1 b) IV)(Hot set test) |
- |
5000 |
|
- |
19.1 b) V)(Shrinkage test) |
- |
5000 |
|
- |
20.3(Test for concentric metallic screen : Test for concentric copper wire) |
- |
5000 |
|
- |
20.4(Test for concentric copper tape) |
- |
5000 |
|
- |
20.5(Thickness of metallic sheath) |
- |
5000 |
|
- |
20.6(Tests for armouring material : Dimensions) |
- |
5000 |
|
- |
19.1 f) II)(Tests for armouring material : Tensile strength and elongation at break) |
- |
5000 |
|
- |
Table 9, (Measurement of thickness) |
- |
5000 |
|
- |
19.1 g)2) i)(PVC sheath : Tensile strength and elongation at break) |
- |
5000 |
|
- |
19.1 g)2) iii)(PVC sheath : Loss of mass) |
- |
5000 |
|
- |
19.1 g)2) v)(PVC sheath : Hot deformation test) |
- |
5000 |
|
- |
19.1 g)2) vi)(PVC sheath : Shrinkage test) |
- |
5000 |
|
- |
19.1 g)2) vii)(PVC sheath : Thermal stability) |
- |
5000 |
|
- |
19.1 g)3) ii)(PE sheath : Tensile strength and elongation at break before and after ageing) |
- |
5000 |
|
- |
19.1 g)3) iii)(PE sheath : Hot-detormation) |
- |
5000 |
|
- |
20.7(Flammabihty test ( for PVC outer
sheathed cables only )) |
- |
8000 |
|
- |
20.8.3(Water tightness test) |
- |
8000 |
|
- |
20.9.1(Thermal ageing on complete cable sample) |
- |
8000 |
|
- |
19.1 k) ii)(Tensile strength and elongation at breakfor insulation and outer sheath) |
- |
5000 |
|
- |
20.2(Resistivity test for semi-conducting layer) |
- |
5000 |
|
- |
20.11.1(Bending test followed by P D test) |
- |
70000 |
|
- |
20.12, 20.18(Dielectric power factor and capacitance measurement at ambient temperature) |
- |
5000 |
|
- |
20.13(Dielectric power factor measurement at elevated temperature) |
- |
5000 |
|
- |
20.14.1(Load cycle test followed by P.D measurement) |
- |
70000 |
|
- |
20.15(Impulse Voltage Test Followed by High Voltage Test) |
- |
50000 |
|
- |
19.5(Check on Insulation Thickness Before the Electrical Type Tests) |
- |
5000 |
|
- |
20.16.1(Test for Dimensions of Insulation : Insulation Thickness) |
- |
5000 |
|
- |
20.16.2(Test for Dimensions of Insulation : Test for Eccentricity) |
- |
5000 |
|
- |
20.16.3(Test for Dimensions of Insulation : Test for Ovality) |
- |
5000 |
|
- |
20.17(High Voltage Test ( as Routine and
Acceptance Tests ) ) |
- |
50000 |
|
- |
20.18(Measurement of Capacitance) |
- |
5000 |
|
- |
4.1(CONDUCTOR) |
- |
1000 |
|
- |
5(INSULATION) |
- |
1000 |
|
- |
6(SCREENING) |
- |
1000 |
|
- |
7.1(MOISTURE BARRIER : Laminated Tape) |
- |
1000 |
|
- |
7.2(MOISTURE BARRIER : Lead Alloy Sheath) |
- |
1000 |
|
- |
7.3(MOISTURE BARRIER : Water Blocking Tape/Powder) |
- |
1000 |
|
- |
8.1(INNER SHEATH) |
- |
1000 |
|
- |
8.2(INNER SHEATH) |
- |
1000 |
|
- |
8.3(INNER SHEATH) |
- |
1000 |
|
- |
9.1(ARMOUR) |
- |
1000 |
|
- |
9.2(ARMOUR) |
- |
1000 |
|
- |
10.1(OUTER SHEATH) |
- |
1000 |
|
- |
10.2(OUTER SHEATH) |
- |
1000 |
|
- |
11.1(CONDUCTOR) |
- |
1000 |
|
- |
11.2(CONDUCTOR) |
- |
1000 |
|
- |
12.1(CONDUCTOR SCREENING ) |
- |
1000 |
|
- |
12.2(CONDUCTOR SCREENING ) |
- |
1000 |
|
- |
13.1(INSULATION) |
- |
1000 |
|
- |
13.2(INSULATION) |
- |
1000 |
|
- |
14.1(INSULATION SCREENING) |
- |
1000 |
|
- |
14.2.1(INSULATION SCREENING : Non-metallic Part) |
- |
1000 |
|
- |
14.2.2(INSULATION SCREENING : Non-metallic Part) |
- |
1000 |
|
- |
14.2.3(INSULATION SCREENING : Non-metallic Part) |
- |
1000 |
|
- |
14.3.1(INSULATION SCREENING : Metallic Part) |
- |
1000 |
|
- |
14.3.2(INSULATION SCREENING : Metallic Part) |
- |
1000 |
|
- |
14.3.3(INSULATION SCREENING : Metallic Part) |
- |
1000 |
|
- |
15.1(MOISTURE BARRIER) |
- |
1000 |
|
- |
15.2.1(Metallic Sheath) |
- |
1000 |
|
- |
15.2.2(Metallic Sheath) |
- |
1000 |
|
- |
16.1(INNER SHEATH) |
- |
1000 |
|
- |
16.2(INNER SHEATH) |
- |
1000 |
|
- |
17.1(ARMOUR) |
- |
1000 |
|
- |
17.2(ARMOUR) |
- |
1000 |
|
- |
17.3(ARMOUR) |
- |
1000 |
|
- |
17.4(ARMOUR) |
- |
1000 |
|
- |
17.5(ARMOUR) |
- |
1000 |
|
- |
18.1(OUTER SHEATH) |
- |
1000 |
|
- |
18.2(outer sheath colour) |
- |
1000 |
|
- |
18.3.1(Thickness of Outer Sheath : Unarmoured Cables) |
- |
5000 |
|
- |
18.3.1(Thickness of Outer Sheath : armoured Cables) |
- |
5000 |
|
- |
19.1 A) I)(Tests on conductor : Annealing test ( for copper )) |
- |
5000 |
|
- |
19.1 A) II)(Tests on conductor : Resistance test) |
- |
5000 |
|
- |
19.1 b) I)(Test for thickness and dimensions of insulation) |
- |
5000 |
|
- |
19.1 b) II)(Tensile strength and elongation at break) |
- |
5000 |
|
- |
19.1 b) III)(Thermal ageing in air oven) |
- |
5000 |
|
- |
19.1 b) IV)(Hot set test) |
- |
5000 |
|
- |
19.1 b) V)(Shrinkage test) |
- |
5000 |
|
- |
20.3(Test for concentric metallic screen : Test for concentric copper wire) |
- |
5000 |
|
- |
20.4(Test for concentric copper tape) |
- |
5000 |
|
- |
20.5(Thickness of metallic sheath) |
- |
5000 |
|
- |
20.6(Tests for armouring material : Dimensions) |
- |
5000 |
|
- |
19.1 f) II)(Tests for armouring material : Tensile strength and elongation at break) |
- |
5000 |
|
- |
Table 9, (Measurement of thickness) |
- |
5000 |
|
- |
19.1 g)2) i)(PVC sheath : Tensile strength and elongation at break) |
- |
5000 |
|
- |
19.1 g)2) iii)(PVC sheath : Loss of mass) |
- |
5000 |
|
- |
19.1 g)2) v)(PVC sheath : Hot deformation test) |
- |
5000 |
|
- |
19.1 g)2) vi)(PVC sheath : Shrinkage test) |
- |
5000 |
|
- |
19.1 g)2) vii)(PVC sheath : Thermal stability) |
- |
5000 |
|
- |
19.1 g)3) ii)(PE sheath : Tensile strength and elongation at break before and after ageing) |
- |
5000 |
|
- |
19.1 g)3) iii)(PE sheath : Hot-detormation) |
- |
5000 |
|
- |
20.7(Flammabihty test ( for PVC outer
sheathed cables only )) |
- |
15000 |
|
- |
20.8.3(Water tightness test) |
- |
10000 |
|
- |
20.9.1(Thermal ageing on complete cable sample) |
- |
8000 |
|
- |
19.1 k) ii)(Tensile strength and elongation at breakfor insulation and outer sheath) |
- |
5000 |
|
- |
20.2(Resistivity test for semi-conducting layer) |
- |
5000 |
|
- |
20.11.1(Bending test followed by P D test) |
- |
95000 |
|
- |
20.12, 20.18(Dielectric power factor and capacitance measurement at ambient temperature) |
- |
8000 |
|
- |
20.13(Dielectric power factor measurement at elevated temperature) |
- |
8000 |
|
- |
20.14.1(Load cycle test followed by P.D measurement) |
- |
95000 |
|
- |
20.15(Impulse Voltage Test Followed by High Voltage Test) |
- |
70000 |
|
- |
19.5(Check on Insulation Thickness Before the Electrical Type Tests) |
- |
5000 |
|
- |
20.16.1(Test for Dimensions of Insulation : Insulation Thickness) |
- |
5000 |
|
- |
20.16.2(Test for Dimensions of Insulation : Test for Eccentricity) |
- |
5000 |
|
- |
20.16.3(Test for Dimensions of Insulation : Test for Ovality) |
- |
5000 |
|
- |
20.17(High Voltage Test ( as Routine and
Acceptance Tests ) ) |
- |
70000 |
|
- |
20.18(Measurement of Capacitance) |
- |
5000 |
|
- |
|
Complete
|
19 Jul, 2024 |
06 Jun, 2027 |
Included w.e.f. 02.01.2024
Size: 95 to 630 sqmm |
9 |
IS 7098 : Part 2 (2011) |
Crosslinked polyethylene insulated thermoplastic sheathed cables - Specification: Part 2 for working voltages from 3.3 kV up to and including 33 kV (Second Revision) |
Size: 25 to 630 sqmm |
-
|
190000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
4.1(CONDUCTOR) |
- |
200 |
|
- |
4.1.1(CONDUCTOR) |
- |
200 |
|
- |
5(INSULATION) |
- |
200 |
|
- |
6(SCREENING) |
- |
200 |
|
- |
6.1.1(SCREENING : - Non-metallic — Semiconducting Compound) |
- |
200 |
|
- |
6.1.2(SCREENING : - Non-magnetic Metallic Tape for Single Core Unscreened and Unarmoured Cables) |
- |
200 |
|
- |
7(FILLERS AND INNER SHEATH) |
- |
500 |
|
- |
8.1(ARMOURING) |
- |
200 |
|
- |
8.2(ARMOURING) |
- |
200 |
|
- |
9(OUTER SHEATH ) |
- |
200 |
|
- |
10.1(CONDUCTOR) |
- |
200 |
|
- |
10.2(CONDUCTOR) |
- |
200 |
|
- |
11(CONDUCTOR SCREENING) |
- |
200 |
|
- |
12.1(INSULATION) |
- |
200 |
|
- |
12.2(INSULATION : Thickness of Insulation) |
- |
200 |
|
- |
12.3(INSULATION : Tolerance on Thickness of Insulation) |
- |
200 |
|
- |
12.4(Eccentricity and Ovality) |
- |
200 |
|
- |
12.5(INSULATION : Application of Insulation) |
- |
200 |
|
- |
13.1(INSULATION SCREENING) |
- |
200 |
|
- |
13.2(INSULATION SCREENING) |
- |
200 |
|
- |
13.3(INSULATION SCREENING) |
- |
200 |
|
- |
13.4(INSULATION SCREENING) |
- |
200 |
|
- |
14.1(CORE IDENTIFICATION) |
- |
200 |
|
- |
14.1.1(CORE IDENTIFICATION) |
- |
200 |
|
- |
15.1(LAVING UP OF CORES) |
- |
200 |
|
- |
16.1(INNER SHEATH (COMMON COVERING)) |
- |
200 |
|
- |
16.2(INNER SHEATH (COMMON COVERING)) |
- |
200 |
|
- |
16.2.1(INNER SHEATH (COMMON COVERING)) |
- |
200 |
|
- |
16.3(INNER SHEATH (COMMON COVERING) : Thickness of Inner Sheath) |
- |
200 |
|
- |
16.3.1(INNER SHEATH (COMMON COVERING) : Thickness of Inner Sheath) |
- |
200 |
|
- |
17.1(ARMOURING : Application ) |
- |
200 |
|
- |
17.1.1(ARMOURING ) |
- |
200 |
|
- |
17.1.2(ARMOURING ) |
- |
200 |
|
- |
17.1.3(ARMOURING ) |
- |
200 |
|
- |
17.2(ARMOURING : Type of armour ) |
- |
200 |
|
- |
17.2.1(ARMOURING : Type of armour ) |
- |
200 |
|
- |
17.2(ARMOURING : Coverage ) |
- |
200 |
|
- |
17.3(ARMOURING : Dimension ) |
- |
200 |
|
- |
17.4(ARMOURING : Joints) |
- |
200 |
|
- |
16.4(ARMOURING : Resistance) |
- |
200 |
|
- |
18.1(OUTER SHEATH) |
- |
200 |
|
- |
18.2(OUTER SHEATH: Colour) |
- |
200 |
|
- |
18.3(Thicknes of outer sheath : average ) |
- |
200 |
|
- |
18.3(Thicknes of outer sheath : minimum ) |
- |
200 |
|
- |
19.1 i) a)(Annealing test (for copper)) |
- |
500 |
|
- |
19.1 i) b)(Tensile test (for aluminium) - Before stranding ) |
- |
1000 |
|
- |
19.1 i) b)(Tensile test (for aluminium) - After stranding ) |
- |
1000 |
|
- |
19.1 i) c)(Wrapping test ( for aluminium)) |
- |
1000 |
|
- |
19.1 i) d)(Resistance test - Main conductor ) |
- |
1000 |
|
- |
19.1 i) d)(Resistance test - Neutral conductor ) |
- |
1000 |
|
- |
19.1 iii) a)(Phyaical tests for insulation : Tensile Test) |
- |
1000 |
|
- |
19.1 iii) a)(Phyaical tests for insulation : Elongation ) |
- |
1000 |
|
- |
19.1 iii) b)(Phyaical tests for insulation - Ageing in air Oven : Tensile Variation ) |
- |
1000 |
|
- |
19.1 iii) b)(Phyaical tests for insulation- Ageing in air oven : Elongation Variation ) |
- |
1000 |
|
- |
19.1 iii) c)(Degree of cross linking ) |
- |
1000 |
|
- |
19.1 iii) d)(Phyaical tests for insulation : Hot set ) |
- |
1000 |
|
- |
19.1 iii) d)(Phyaical tests for insulation : Permanent set ) |
- |
1000 |
|
- |
19.1 iii) e)(Phyaical tests for insulation : Shrinkage ) |
- |
1000 |
|
- |
19.1 iii) e)(Phyaical tests for insulation : Shrinkage - Crack observed ) |
- |
1000 |
|
- |
19.1 iii) f)(Insulation: Waterabsorption(gravimetric)) |
- |
2500 |
|
- |
19.1 v) a)(Test for strippability of semiconducting strippable insulation screen
(when applicable)) |
- |
1000 |
|
- |
19.1 v) b)(Volume resistivity) |
- |
1500 |
|
- |
19.1 vi) a)(Physical tests for outer sheath : Tensile stregth ) |
- |
1500 |
|
- |
19.1 vi) a)(Physical tests for outer sheath : Elongation ) |
- |
1500 |
|
- |
19.1 vi) b)(Physical tests for outer sheath- Ageing in air oven : Tensile stregth ) |
- |
1500 |
|
- |
19.1 vi) b)(Physical tests for outer sheath -Ageing in air oven : Elongation ) |
- |
1500 |
|
- |
19.1 vi) c)(Phyaical tests for Sheath : Shrinkage ) |
- |
1500 |
|
- |
19.1 vi) c)(Phyaical tests for Sheath : Shrinkage - Crack observed ) |
- |
1500 |
|
- |
19.1 vi) d)(Sheath : Hot deformation) |
- |
1500 |
|
- |
19.1 vi) e)(Loss of massIn air oven) |
- |
1500 |
|
- |
19.1 vi) f)(Sheath : Heat shock test) |
- |
1500 |
|
- |
19.1 vi) g)(Sheath : Thermalstability) |
- |
1500 |
|
- |
19.1 vi) h)(Carbon black content of polythene
sheath ) |
- |
1500 |
|
- |
19.1 vii)(Thermal ageing test for complete cable - Tensile stregth ) |
- |
1500 |
|
- |
19.1 vii)(Thermal ageing test for complete cable- Elogation ) |
- |
1500 |
|
- |
19.1 vii)(Thermal ageing test for complete cable- Resistivity ) |
- |
1500 |
|
- |
19.1 xi)(Insulation resistance test : volume resistivity ) |
- |
1500 |
|
- |
20.2(Partial discharge test) |
- |
35000 |
|
- |
20.3(Bending test) |
- |
1000 |
|
- |
20.4(Dielectric power factor test : As a function of voltage) |
- |
1000 |
|
- |
20.4(Dielectric power factor test : As a function of temperature) |
- |
1000 |
|
- |
20.5(Heating Cycle Test) |
- |
25000 |
|
- |
20.6(Impulse withstand test
(Rated voltage, kV 3.8/6.6
Impulse voltage, kV 60)) |
- |
25000 |
|
- |
20.7(High voltage test) |
- |
25000 |
|
- |
20.8(Flammability test) |
- |
5000 |
|
- |
20.1(Oxygen Index Test) |
- |
5000 |
|
- |
20.11(Flame Retardance Test on Single Cables) |
- |
5000 |
|
- |
20.12(Flame Retardance Test on Bunched Cables) |
- |
8000 |
|
- |
20.13(Test for Halogen Acid Gas Evolution) |
- |
8000 |
|
- |
20.14( Test for Smoke Density) |
- |
5000 |
|
- |
20.15(Temperature Index) |
- |
5000 |
|
- |
21.1(IDENTIFICATION : Manufacturer's Identification) |
- |
200 |
|
- |
21.2(IDENTIFICATION : Cable Identification) |
- |
200 |
|
- |
21.3(IDENTIFICATION : Cable Code) |
- |
200 |
|
- |
20.3 (a)(Partial discharge test (Bending test)) |
- |
35000 |
|
- |
20.5 (a)(PD test (heating cycle test)) |
- |
35000 |
|
- |
20.6(Impulse Withstand Test
(Rated voltage, kV 6.35/11
Impulse voltage, kV 75)) |
- |
25000 |
|
- |
20.6(Impulse Withstand Test
(Rated voltage, kV 11/11
Impulse voltage, kV 95)) |
- |
25000 |
|
- |
20.6(Impulse Withstand Test
(Rated voltage, kV 12.7/22
Impulse voltage, kV 125)) |
- |
25000 |
|
- |
20.6(Impulse Withstand Test
(Rated voltage, kV 19/33
Impulse voltage, kV 170)) |
- |
25000 |
|
- |
19.1 vi) b)(Physical tests for outer sheath- Ageing in air oven : Tensile stregth Variation ) |
- |
1000 |
|
- |
19.1 vi) b)(Physical tests for outer sheath -Ageing in air oven : Elongation Variation ) |
- |
1000 |
|
- |
4.1(CONDUCTOR) |
- |
200 |
|
- |
4.1.1(CONDUCTOR) |
- |
200 |
|
- |
5(INSULATION) |
- |
200 |
|
- |
6(SCREENING) |
- |
200 |
|
- |
6.1.1(SCREENING : - Non-metallic — Semiconducting Compound) |
- |
200 |
|
- |
6.1.2(SCREENING : - Non-magnetic Metallic Tape for Single Core Unscreened and Unarmoured Cables) |
- |
200 |
|
- |
7(FILLERS AND INNER SHEATH) |
- |
500 |
|
- |
8.1(ARMOURING) |
- |
200 |
|
- |
8.2(ARMOURING) |
- |
200 |
|
- |
9(OUTER SHEATH ) |
- |
200 |
|
- |
10.1(CONDUCTOR) |
- |
200 |
|
- |
10.2(CONDUCTOR) |
- |
200 |
|
- |
11(CONDUCTOR SCREENING) |
- |
200 |
|
- |
12.1(INSULATION) |
- |
200 |
|
- |
12.2(INSULATION : Thickness of Insulation) |
- |
200 |
|
- |
12.3(INSULATION : Tolerance on Thickness of Insulation) |
- |
200 |
|
- |
12.4(Eccentricity and Ovality) |
- |
200 |
|
- |
12.5(INSULATION : Application of Insulation) |
- |
200 |
|
- |
13.1(INSULATION SCREENING) |
- |
200 |
|
- |
13.2(INSULATION SCREENING) |
- |
200 |
|
- |
13.3(INSULATION SCREENING) |
- |
200 |
|
- |
13.4(INSULATION SCREENING) |
- |
200 |
|
- |
14.1(CORE IDENTIFICATION) |
- |
200 |
|
- |
14.1.1(CORE IDENTIFICATION) |
- |
200 |
|
- |
15.1(LAVING UP OF CORES) |
- |
200 |
|
- |
16.1(INNER SHEATH (COMMON COVERING)) |
- |
200 |
|
- |
16.2(INNER SHEATH (COMMON COVERING)) |
- |
200 |
|
- |
16.2.1(INNER SHEATH (COMMON COVERING)) |
- |
200 |
|
- |
16.3(INNER SHEATH (COMMON COVERING) : Thickness of Inner Sheath) |
- |
200 |
|
- |
16.3.1(INNER SHEATH (COMMON COVERING) : Thickness of Inner Sheath) |
- |
200 |
|
- |
17.1(ARMOURING : Application ) |
- |
200 |
|
- |
17.1.1(ARMOURING ) |
- |
200 |
|
- |
17.1.2(ARMOURING ) |
- |
200 |
|
- |
17.1.3(ARMOURING ) |
- |
200 |
|
- |
17.2(ARMOURING : Type of armour ) |
- |
200 |
|
- |
17.2.1(ARMOURING : Type of armour ) |
- |
200 |
|
- |
17.2(ARMOURING : Coverage ) |
- |
200 |
|
- |
17.3(ARMOURING : Dimension ) |
- |
200 |
|
- |
17.4(ARMOURING : Joints) |
- |
200 |
|
- |
16.4(ARMOURING : Resistance) |
- |
200 |
|
- |
18.1(OUTER SHEATH) |
- |
200 |
|
- |
18.2(OUTER SHEATH: Colour) |
- |
200 |
|
- |
18.3(Thicknes of outer sheath : average ) |
- |
200 |
|
- |
18.3(Thicknes of outer sheath : minimum ) |
- |
200 |
|
- |
19.1 i) a)(Annealing test (for copper)) |
- |
500 |
|
- |
19.1 i) b)(Tensile test (for aluminium) - Before stranding ) |
- |
1000 |
|
- |
19.1 i) b)(Tensile test (for aluminium) - After stranding ) |
- |
1000 |
|
- |
19.1 i) c)(Wrapping test ( for aluminium)) |
- |
1000 |
|
- |
19.1 i) d)(Resistance test - Main conductor ) |
- |
1000 |
|
- |
19.1 i) d)(Resistance test - Neutral conductor ) |
- |
1000 |
|
- |
19.1 iii) a)(Phyaical tests for insulation : Tensile Test) |
- |
1000 |
|
- |
19.1 iii) a)(Phyaical tests for insulation : Elongation ) |
- |
1000 |
|
- |
19.1 iii) b)(Phyaical tests for insulation - Ageing in air Oven : Tensile Variation ) |
- |
1000 |
|
- |
19.1 iii) b)(Phyaical tests for insulation- Ageing in air oven : Elongation Variation ) |
- |
1000 |
|
- |
19.1 iii) c)(Degree of cross linking ) |
- |
1000 |
|
- |
19.1 iii) d)(Phyaical tests for insulation : Hot set ) |
- |
1000 |
|
- |
19.1 iii) d)(Phyaical tests for insulation : Permanent set ) |
- |
1000 |
|
- |
19.1 iii) e)(Phyaical tests for insulation : Shrinkage ) |
- |
1000 |
|
- |
19.1 iii) e)(Phyaical tests for insulation : Shrinkage - Crack observed ) |
- |
1000 |
|
- |
19.1 iii) f)(Insulation: Waterabsorption(gravimetric)) |
- |
2500 |
|
- |
19.1 v) a)(Test for strippability of semiconducting strippable insulation screen
(when applicable)) |
- |
1000 |
|
- |
19.1 v) b)(Volume resistivity) |
- |
1500 |
|
- |
19.1 vi) a)(Physical tests for outer sheath : Tensile stregth ) |
- |
1500 |
|
- |
19.1 vi) a)(Physical tests for outer sheath : Elongation ) |
- |
1500 |
|
- |
19.1 vi) b)(Physical tests for outer sheath- Ageing in air oven : Tensile stregth ) |
- |
1500 |
|
- |
19.1 vi) b)(Physical tests for outer sheath -Ageing in air oven : Elongation ) |
- |
1500 |
|
- |
19.1 vi) c)(Phyaical tests for Sheath : Shrinkage ) |
- |
1500 |
|
- |
19.1 vi) c)(Phyaical tests for Sheath : Shrinkage - Crack observed ) |
- |
1500 |
|
- |
19.1 vi) d)(Sheath : Hot deformation) |
- |
1500 |
|
- |
19.1 vi) e)(Loss of massIn air oven) |
- |
1500 |
|
- |
19.1 vi) f)(Sheath : Heat shock test) |
- |
1500 |
|
- |
19.1 vi) g)(Sheath : Thermalstability) |
- |
1500 |
|
- |
19.1 vi) h)(Carbon black content of polythene
sheath ) |
- |
1500 |
|
- |
19.1 vii)(Thermal ageing test for complete cable - Tensile stregth ) |
- |
1500 |
|
- |
19.1 vii)(Thermal ageing test for complete cable- Elogation ) |
- |
1500 |
|
- |
19.1 vii)(Thermal ageing test for complete cable- Resistivity ) |
- |
1500 |
|
- |
19.1 xi)(Insulation resistance test : volume resistivity ) |
- |
1500 |
|
- |
20.2(Partial discharge test) |
- |
35000 |
|
- |
20.3(Bending test) |
- |
1000 |
|
- |
20.4(Dielectric power factor test : As a function of voltage) |
- |
1000 |
|
- |
20.4(Dielectric power factor test : As a function of temperature) |
- |
1000 |
|
- |
20.5(Heating Cycle Test) |
- |
25000 |
|
- |
20.6(Impulse withstand test
(Rated voltage, kV 3.8/6.6
Impulse voltage, kV 60)) |
- |
25000 |
|
- |
20.7(High voltage test) |
- |
25000 |
|
- |
20.8(Flammability test) |
- |
5000 |
|
- |
20.1(Oxygen Index Test) |
- |
5000 |
|
- |
20.11(Flame Retardance Test on Single Cables) |
- |
5000 |
|
- |
20.12(Flame Retardance Test on Bunched Cables) |
- |
8000 |
|
- |
20.13(Test for Halogen Acid Gas Evolution) |
- |
8000 |
|
- |
20.14( Test for Smoke Density) |
- |
5000 |
|
- |
20.15(Temperature Index) |
- |
5000 |
|
- |
21.1(IDENTIFICATION : Manufacturer's Identification) |
- |
200 |
|
- |
21.2(IDENTIFICATION : Cable Identification) |
- |
200 |
|
- |
21.3(IDENTIFICATION : Cable Code) |
- |
200 |
|
- |
20.3 (a)(Partial discharge test (Bending test)) |
- |
35000 |
|
- |
20.5 (a)(PD test (heating cycle test)) |
- |
35000 |
|
- |
20.6(Impulse Withstand Test
(Rated voltage, kV 6.35/11
Impulse voltage, kV 75)) |
- |
25000 |
|
- |
20.6(Impulse Withstand Test
(Rated voltage, kV 11/11
Impulse voltage, kV 95)) |
- |
25000 |
|
- |
20.6(Impulse Withstand Test
(Rated voltage, kV 12.7/22
Impulse voltage, kV 125)) |
- |
25000 |
|
- |
20.6(Impulse Withstand Test
(Rated voltage, kV 19/33
Impulse voltage, kV 170)) |
- |
25000 |
|
- |
19.1 vi) b)(Physical tests for outer sheath- Ageing in air oven : Tensile stregth Variation ) |
- |
1000 |
|
- |
19.1 vi) b)(Physical tests for outer sheath -Ageing in air oven : Elongation Variation ) |
- |
1000 |
|
- |
|
Complete
|
19 Jul, 2024 |
06 Jun, 2027 |
Included w.e.f. 02.01.2024
Size: 25 to 630 sqmm |
10 |
IS 17048 (2018) |
Halogen free flame retardant (HFFR) cables for working voltages up to and including 1 100 Volts - Specification |
Size: 0.5-630 sqmm |
-
|
160000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
4.1.1 a) (Conductor : Material ) |
- |
500 |
|
- |
4.1.1 b) (Material : Seperator tape ) |
- |
500 |
|
- |
4.1.1 d) , 11.1, 12.1, 13.1,14.1(Class of conductor ) |
- |
500 |
|
- |
4.1.1 e) (Shape of conductor ) |
- |
500 |
|
- |
4.1.1 f) (Nominal size of conductor ) |
- |
500 |
|
- |
4.2.1, 11.2, 12.2, 13.2, 14.2(Insulation : Material ) |
- |
500 |
|
- |
4.2.2, 11.2, 12.2, 13.2, 14.2(Insulation : Application ) |
- |
500 |
|
- |
4.2.3,11.2, 12.2, 13.2(Thickness of insulation - Avearge : IS 10810 ( Part 6 )) |
- |
1000 |
|
- |
4.2.3, 11.2, 12.2, 13.2, 14.2(Thickness of insulation - miniumum : IS 10810 ( Part 6 )) |
- |
1000 |
|
- |
4.2.4(Insulation : Tensile stregth ( Before ageing)-IS 10810 (Part 7) ) |
- |
1500 |
|
- |
4.2.4(Insulation : Elongation ( Before ageing) -IS 10810 (Part 7)) |
- |
1000 |
|
- |
4.2.4(Insulation : Tensile stregth ( After ageing) - IS 10810 (Part 7) ) |
- |
1500 |
|
- |
4.2.4(Insulation : Elongation (after ageing) - IS 10810 (Part 7) ) |
- |
1000 |
|
- |
4.2.5(Insulation : Elongation variation (after ageing) - IS 10810 (Part 7) ) |
- |
1000 |
|
- |
4.3(Fillers) |
- |
500 |
|
- |
4.4(Binder Tape) |
- |
500 |
|
- |
4.5.1,13.4, 14.4(Sheath : Compound ) |
- |
500 |
|
- |
4.5.2, 13.4, 14.4(Sheath : Application) |
- |
500 |
|
- |
4.5.3,13.4, 14.4(Thickness of sheath - Average : IS 10810 (Part 6)) |
- |
1000 |
|
- |
4.5.3,13.4, 14.4(Thickness of sheath - Minimum : IS 10810 (Part 6)) |
- |
1000 |
|
- |
4.5.4, 13.4(Sheath : Tensile stregth ( Before ageing)-IS 10810 (Part 7) ) |
- |
1500 |
|
- |
4.5.4,13.4(Sheath : Elongation ( Before ageing) -IS 10810 (Part 7)) |
- |
1000 |
|
- |
4.5.4, 13.4, 14.4(Sheath : Tensile stregth ( After ageing) - IS 10810 (Part 7) ) |
- |
1500 |
|
- |
4.5.5, 13.4, 14.4(Sheath : Tensile stregth variation ( After ageing) - IS 10810 (Part 7) ) |
- |
1500 |
|
- |
4.5.4, 13.4, 14.4(Sheath : Elongation (after ageing) - IS 10810 (Part 7) ) |
- |
1000 |
|
- |
4.5.5, 13.4,14.4(Sheath : Elongation variation (after ageing) - IS 10810 (Part 7) ) |
- |
1000 |
|
- |
4.5.5, 11.3, 12.3, 13.6, 14.6(Overall Dimensions) |
- |
1500 |
|
- |
4.5.5.1, 11.3, 12.3,13.5, 14.5(Ovality) |
- |
500 |
|
- |
4.5.6, 13.4(Colour of Sheath) |
- |
500 |
|
- |
5.1(High Voltage Test (at Room Temperature)) |
- |
15000 |
|
- |
5.3(Flammability Test- IS 10810 (Part 53).) |
- |
4000 |
|
- |
5.4(Oxygen Index Test- IS 10810 (Part 58)) |
- |
3000 |
|
- |
5.5(Temperature Index-IS 10810 (Part 64).) |
- |
4000 |
|
- |
5.6(Smoke Density-IS 10810 (Part 63).) |
- |
4000 |
|
- |
5.7(Assessment of Halogen- Table 1 of Annex D) |
- |
15000 |
|
- |
5.1(Persulphate Test- IS 10810 (Part 4).) |
- |
2000 |
|
- |
5.11(Flame Retardant Test- IS 10810 (Part 61),) |
- |
4000 |
|
- |
5.12(Hot Set Test- IS 10810 (Part 30).) |
- |
4000 |
|
- |
5.12(Permanent Set - IS 10810 (Part 30).) |
- |
4000 |
|
- |
5.13(Water Immersion Test (Effect of Water on Sheath) : Tensile strength -IS 10810 (Part 7).) |
- |
4000 |
|
- |
5.14(Ozone Resistance Test -IS 10810 (Part 13 )) |
- |
4000 |
|
- |
5.15(Cold Bend Test-IS 10810 (Part 20).) |
- |
4000 |
|
- |
5.16(Cold Impact Test- IS 10810 (Part 21).) |
- |
4000 |
|
- |
6.1, Table 1(CORE IDENTIFICATION) |
- |
500 |
|
- |
6.2(Core Identification by Numbers) |
- |
500 |
|
- |
7.0(CABLE CODE) |
- |
500 |
|
- |
9.0( IDENTIFICATION) |
- |
500 |
|
- |
10.1(Packing ) |
- |
500 |
|
- |
10.2(marking) |
- |
500 |
|
- |
10.2.1(Standards marking) |
- |
500 |
|
- |
13.3, 14.3(assembly of cores ) |
- |
500 |
|
- |
6.1(General Requirements) |
- |
500 |
|
- |
6.1.1(Colour Combination Green Yellow) |
- |
500 |
|
- |
12.1(Conductor) |
- |
500 |
|
- |
12.2, Table 4(insulation) |
- |
500 |
|
- |
Table 4(Copper Purity test) |
- |
5000 |
|
- |
4.3.1 (e)(Fluorine content test (Fillers)) |
- |
2000 |
|
- |
4.3.1 (d)(Presence of fluorine test (Fillers)) |
- |
2000 |
|
- |
4.3.1 (c)(Conductivity test (Fillers)) |
- |
2000 |
|
- |
4.3.1 (b)(pH test (Fillers)) |
- |
2000 |
|
- |
4.3.1 (a)(HCl test (Fillers)) |
- |
2000 |
|
- |
5.7 (a)(HCl test (Assessment of halogen test)) |
- |
2000 |
|
- |
5.7 (b)(pH test (Assessment of halogen test)) |
- |
2000 |
|
- |
5.7 (c)(Conductivity test (Assessment of halogen test)) |
- |
2000 |
|
- |
5.7 (d)(Presence of fluorine test (Assessment of halogen test)) |
- |
2000 |
|
- |
5.7 (e)(Fluorine content test (Assessment of halogen test)) |
- |
2000 |
|
- |
Table 2 ,( Clause 11.4, 12.4, 13.7 14.7 and 15.7 )(Insulation Resistance) |
- |
5000 |
|
- |
"Table 2 ( Clause 11.4, 12.4, 13.7 14.7 and 15.7 )"(Conductor Resistance) |
- |
3000 |
|
- |
Table 2 , Clause .5.13(Water immersion test (Effect of water on sheath) - TS Variation of Sheath) |
- |
6000 |
|
- |
Table 2 , Clause 5.13(Water immersion test (Effect of water on sheath) - Elongation Variation of Sheath) |
- |
6000 |
|
- |
"Table 2 ( Clause 11.4, 12.4, 13.7 14.7 and 15.7 )"(Hot Deformation) |
- |
5000 |
|
- |
Table 2, III.a.ii(Annealing test (for Cu,
before stranding)) |
- |
2500 |
|
- |
Table 2, II.a, b(Wrapping test before
stranding (for Al)) |
- |
2500 |
|
- |
6.1, Table 1(CORE IDENTIFICATION) |
- |
500 |
|
- |
6.1(General Requirements) |
- |
500 |
|
- |
6.1.1(Colour Combination Green Yellow) |
- |
50 |
|
- |
12.1(Conductor) |
- |
500 |
|
- |
12.2, Table 4(insulation) |
- |
500 |
|
- |
Table 4(Copper Purity test) |
- |
5000 |
|
- |
4.3.1 (e)(Fluorine content test (Fillers)) |
- |
2000 |
|
- |
4.3.1 (d)(Presence of fluorine test (Fillers)) |
- |
2000 |
|
- |
4.3.1 (c)(Conductivity test (Fillers)) |
- |
2000 |
|
- |
4.3.1 (b)(pH test (Fillers)) |
- |
2000 |
|
- |
4.3.1 (a)(HCl test (Fillers)) |
- |
2000 |
|
- |
5.7 (a)(HCl test (Assessment of halogen test)) |
- |
2000 |
|
- |
5.7 (b)(pH test (Assessment of halogen test)) |
- |
2000 |
|
- |
5.7 (c)(Conductivity test (Assessment of halogen test)) |
- |
2000 |
|
- |
5.7 (d)(Presence of fluorine test (Assessment of halogen test)) |
- |
2000 |
|
- |
5.7 (e)(Fluorine content test (Assessment of halogen test)) |
- |
2000 |
|
- |
Table 2 ,( Clause 11.4, 12.4, 13.7 14.7 and 15.7 )(Insulation Resistance) |
- |
5000 |
|
- |
"Table 2 ( Clause 11.4, 12.4, 13.7 14.7 and 15.7 )"(Conductor Resistance) |
- |
3000 |
|
- |
Table 2 , Clause .5.13(Water immersion test (Effect of water on sheath) - TS Variation of Sheath) |
- |
6000 |
|
- |
Table 2 , Clause 5.13(Water immersion test (Effect of water on sheath) - Elongation Variation of Sheath) |
- |
6000 |
|
- |
"Table 2 ( Clause 11.4, 12.4, 13.7 14.7 and 15.7 )"(Hot Deformation) |
- |
5000 |
|
- |
Table 2, III.a.ii(Annealing test (for Cu,
before stranding)) |
- |
2500 |
|
- |
Table 2, II.a, b(Wrapping test before
stranding (for Al)) |
- |
2500 |
|
- |
|
Complete
|
19 Jul, 2024 |
06 Jun, 2027 |
Included w.e.f. 02.01.2024
Size: 0.5 to 630 sqmm |
11 |
IS 16333 : Part 3 (2022) |
Mobile phone handsets: Part 3 Indian language support for mobile phone handsets - Specific requirements(Second Revision) |
- |
-
|
15000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
5.1(Inputting of text) |
- |
4500 |
|
10% discount to BIS |
5.2(Message Readability) |
- |
10000 |
|
10% discount to BIS |
6(Marking) |
- |
500 |
|
10% discount to BIS |
|
Complete
|
19 Jul, 2024 |
06 Jun, 2027 |
Revised version of IS 16333(P-3):2022 Included w.e.f. 20.11.2023 |
12 |
IS 3854 (1997) |
Switches for domestic and similar purposes - Specification (Second Revision) |
Upto 16A |
-
|
11850 View breakup
Rs.8800 for 6 A screw type; Rs.7350 for 6 A screwless type; Rs.8800/- for 10 A screw type; Rs.8800 for 10 A screwless type; Rs.9600/- for 16 screw type. Rs.11850/- for 16 screwless type.
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
6(Rating) |
- |
150 |
|
20% Discount for BIS |
7(Classification) |
- |
150 |
|
20% Discount for BIS |
8(Marking) |
- |
150 |
|
20% Discount for BIS |
10(Protection against Electric Shock) |
- |
300 |
|
20% Discount for BIS |
11.1(Provision for earthing) |
- |
300 |
|
20% Discount for BIS |
11.2(Provision for earthing) |
- |
300 |
|
20% Discount for BIS |
11.3(Provision for earthing) |
- |
300 |
|
20% Discount for BIS |
11.4(Provision for earthing) |
- |
300 |
|
20% Discount for BIS |
12.2(Terminals) |
- |
1000 |
|
20% Discount for BIS |
12.3(Terminals) |
- |
1500 |
|
20% Discount for BIS |
13(Constructional
requirements
) |
- |
800 |
|
20% Discount for BIS |
14(Mechanism [Cl. 14]) |
- |
350 |
|
20% Discount for BIS |
15.1(Resistance to Ageing, to Harmful Ingress of water and to Humidity [Cl. 15]: Resistance to Ageing, [Cl. 15.1]) |
- |
500 |
|
20% Discount for BIS |
15.2(b)Resistance to Harmful ingress of water [Cl. 15.2]) |
- |
500 |
|
20% Discount for BIS |
15.3(c) Resistance to Humidity [Cl. 15.3]) |
- |
500 |
|
20% Discount for BIS |
16(Insulation
resistance and electric strength
) |
- |
600 |
|
20% Discount for BIS |
17(Temperature- rise [Cl. 17]) |
- |
800 |
|
20% Discount for BIS |
18(Marking and breaking Capacity[Cl. 18]) |
- |
1500 |
|
20% Discount for BIS |
19(Normal Operation [Cl. 19] a) General & Operation) |
- |
3000 |
|
20% Discount for BIS |
20(Mechanical Strength Test [Cl. 20]) |
- |
300 |
|
20% Discount for BIS |
21(Resistance to Heat [Cl.21]) |
- |
500 |
|
20% Discount for BIS |
22(Screw, Current Carrying Part And Connection [Cl.22]) |
- |
350 |
|
20% Discount for BIS |
23(Creepage distances, clearances and distance through sealing compound [Cl.23]) |
- |
350 |
|
20% Discount for BIS |
24.1.1(Resistance to Abnormal Heat & Fire [Cl.24.1] [Glow Wire Test] [Cl.24.1.1]) |
- |
400 |
|
20% Discount for BIS |
24.2(Resistance to tracking [For Switch other than ordinary] [Cl.24.2]) |
- |
400 |
|
20% Discount for BIS |
25 of IS 3854 : 1997(Resistance to rusting) |
- |
350 |
|
20% Discount for BIS |
6(Rating) |
- |
150 |
|
20% Discount for BIS |
7(Classification) |
- |
150 |
|
20% Discount for BIS |
8(Marking) |
- |
150 |
|
20% Discount for BIS |
10(Protection against Electric Shock) |
- |
300 |
|
20% Discount for BIS |
11.1(Provision for earthing) |
- |
300 |
|
20% Discount for BIS |
11.2(Provision for earthing) |
- |
300 |
|
20% Discount for BIS |
11.3(Provision for earthing) |
- |
300 |
|
20% Discount for BIS |
11.4(Provision for earthing) |
- |
300 |
|
20% Discount for BIS |
12.2(Terminals) |
- |
1000 |
|
20% Discount for BIS |
12.3(Terminals) |
- |
1500 |
|
20% Discount for BIS |
13(Constructional
requirements
) |
- |
800 |
|
20% Discount for BIS |
14(Mechanism [Cl. 14]) |
- |
350 |
|
20% Discount for BIS |
15.1(Resistance to Ageing, to Harmful Ingress of water and to Humidity [Cl. 15]: Resistance to Ageing, [Cl. 15.1]) |
- |
500 |
|
20% Discount for BIS |
15.2(b)Resistance to Harmful ingress of water [Cl. 15.2]) |
- |
500 |
|
20% Discount for BIS |
15.3(c) Resistance to Humidity [Cl. 15.3]) |
- |
500 |
|
20% Discount for BIS |
16(Insulation
resistance and electric strength
) |
- |
600 |
|
20% Discount for BIS |
17(Temperature- rise [Cl. 17]) |
- |
800 |
|
20% Discount for BIS |
18(Marking and breaking Capacity[Cl. 18]) |
- |
1500 |
|
20% Discount for BIS |
19(Normal Operation [Cl. 19] a) General & Operation) |
- |
3000 |
|
20% Discount for BIS |
20(Mechanical Strength Test [Cl. 20]) |
- |
300 |
|
20% Discount for BIS |
21(Resistance to Heat [Cl.21]) |
- |
500 |
|
20% Discount for BIS |
22(Screw, Current Carrying Part And Connection [Cl.22]) |
- |
350 |
|
20% Discount for BIS |
23(Creepage distances, clearances and distance through sealing compound [Cl.23]) |
- |
350 |
|
20% Discount for BIS |
24.1.1(Resistance to Abnormal Heat & Fire [Cl.24.1] [Glow Wire Test] [Cl.24.1.1]) |
- |
400 |
|
20% Discount for BIS |
24.2(Resistance to tracking [For Switch other than ordinary] [Cl.24.2]) |
- |
400 |
|
20% Discount for BIS |
25 of IS 3854 : 1997(Resistance to rusting) |
- |
350 |
|
20% Discount for BIS |
|
Complete
|
19 Jul, 2024 |
06 Jun, 2027 |
- |
13 |
IS 15885 : Part 2 : Sec 13 (2012) |
Safety of lamp controlgear: Part 2 particular requirements: Sec 13 d.c. or a.c. supplied electronic controlgear for led modules |
- |
-
|
50000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
7(Marking) |
- |
1000 |
|
20% Discount to BIS |
8(Protection against accidental contact with live parts) |
- |
2150 |
|
20% Discount to BIS |
9(Terminals) |
- |
6650 |
|
20% Discount to BIS |
10(PROVISION FOR EARTHING) |
- |
2250 |
|
20% Discount to BIS |
11(MOISTURE RESISTANCE) |
- |
5600 |
|
20% Discount to BIS |
12(Electric Strength) |
- |
3600 |
|
20% Discount to BIS |
14(Fault conditions) |
- |
8100 |
|
20% Discount to BIS |
15(Transformer heating) |
- |
6550 |
|
20% Discount to BIS |
16(Construction) |
- |
1500 |
|
20% Discount to BIS |
17(Creepage distance and clearances) |
- |
3150 |
|
20% Discount to BIS |
18(Screws, current carrying parts and connections) |
- |
1900 |
|
20% Discount to BIS |
19(Resistance to heat, fire and tracking) |
- |
5250 |
|
20% Discount to BIS |
20(Resistance to corrosion) |
- |
2000 |
|
20% Discount to BIS |
|
Complete
|
19 Jul, 2024 |
06 Jun, 2027 |
Up to 300V AC, 50Hz and 150V DC.
Excluding: Components (Annex-1) |
14 |
IS 10322 : Part 5 : Sec 1 (2012) |
Luminaires: Part 5 particular requirements: Sec 1 fixed general purpose luminaires (First Revision) |
- |
-
|
50000 View breakup
Rs.50,000/-
[10% discount to BIS]
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
6.0(Marking) |
- |
1800 |
|
20 % Discount to BIS |
7.0(Construction) |
- |
17160 |
|
20 % Discount to BIS |
8.0(Creepage Distance and Clearances) |
- |
4080 |
|
20 % Discount to BIS |
9.0(Provision for earthing) |
- |
6000 |
|
20 % Discount to BIS |
10.0(Terminals) |
- |
2580 |
|
20 % Discount to BIS |
11.0(External & Internal Wiring) |
- |
1800 |
|
20 % Discount to BIS |
12.0(Protection against electric shock) |
- |
1260 |
|
20 % Discount to BIS |
13.0(Endurance Tests and Thermal Tests) |
- |
8760 |
|
20 % Discount to BIS |
14.0(Resistance to Dust & Moisture) |
- |
7920 |
|
20 % Discount to BIS |
15.0(Insulation Resistance and Electric Strength) |
- |
1920 |
|
20 % Discount to BIS |
16.0(Resistance to Heat , fire and tracking) |
- |
6720 |
|
20 % Discount to BIS |
|
Complete
|
19 Jul, 2024 |
06 Jun, 2027 |
Up to & including 300V AC, 50Hz and 150V DC.
Excluding:
UV Radiation (Cl.4.24, Annex-P), Photometric test (Cl.17). |
15 |
IS 9857 (1990) |
Welding cables - Specification (First Revision) |
- |
-
|
16000 View breakup
SE 1 Covering Cable Rs. 13500.00
SE 3 Covering Cable Rs. 15000.00
Copper Conductor (Extra Charges For Static Flexibility Test) Rs. 900.00
Separated Wire Before Stranding (If Provided) Rs. 900.00
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
10.1 a) 1)(Annealing test - IS 10810: Part 1) |
- |
625 |
|
20% Discount to BIS |
10.1 a) 2)(Conductor resistance tes - IS 10810 : Part 5) |
- |
625 |
|
20% Discount to BIS |
10.1 c) 1)(Physical tests for
covering : Tensile strength ) |
- |
625 |
|
20% Discount to BIS |
10.1 c) 1)(Physical tests for
covering : Elongation at break ) |
- |
625 |
|
20% Discount to BIS |
10.1 c) 3)(Physical tests for
covering - Ageing in Air Bomb : Tensile strength variation ) |
- |
3750 |
|
20% Discount to BIS |
10.1 c) 3)(Physical tests for
covering -Ageing in Air Bomb : Elongation variation at break ) |
- |
3125 |
|
20% Discount to BIS |
10.1 c) 4)(Physical tests for
covering - Oil Resistance : Tensile strength variation ) |
- |
2500 |
|
20% Discount to BIS |
10.1 c) 5)(Hot set test ) |
- |
2500 |
|
20% Discount to BIS |
11.1(High Voltage Test ( Water Immersion
Test )) |
- |
1875 |
|
20% Discount to BIS |
11.3(Static Flexibility Test) |
- |
625 |
|
20% Discount to BIS |
10.1 a) 1)(Annealing test - IS 10810: Part 1) |
- |
- |
|
- |
10.1 a) 2)(Conductor resistance tes - IS 10810 : Part 5) |
- |
- |
|
- |
10.1 c) 1)(Physical tests for
covering : Tensile strength ) |
- |
- |
|
- |
10.1 c) 1)(Physical tests for
covering : Elongation at break ) |
- |
- |
|
- |
10.1 c) 3)(Physical tests for
covering - Ageing in Air Bomb : Tensile strength variation ) |
- |
- |
|
- |
10.1 c) 3)(Physical tests for
covering -Ageing in Air Bomb : Elongation variation at break ) |
- |
- |
|
- |
10.1 c) 4)(Physical tests for
covering - Oil Resistance : Tensile strength variation ) |
- |
- |
|
- |
10.1 c) 5)(Hot set test ) |
- |
- |
|
- |
11.1(High Voltage Test ( Water Immersion
Test )) |
- |
- |
|
- |
11.3(Static Flexibility Test) |
- |
- |
|
- |
|
Complete
|
19 Jul, 2024 |
06 Jun, 2027 |
- |
16 |
IS 9537 : Part 2 (1981) |
Specification for conduits for electrical installations: Part 2 rigid steel conduits |
- |
-
|
3150 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
8.1(Construction, Cl. 8 of IS 9537-1) |
- |
250 |
|
20% Discount to BIS |
8.2(Construction, IS 9537-2) |
- |
250 |
|
20% Discount to BIS |
6.1(Marking, IS 9537-2) |
- |
200 |
|
20% Discount to BIS |
6.2(Marking, IS 9537-2) |
- |
200 |
|
20% Discount to BIS |
6.3(Marking, Cl. 6.4 of IS 9537-1) |
- |
100 |
|
20% Discount to BIS |
7.2.1(Dimensions, (Minimum outside Diameter), IS 9537-2) |
- |
500 |
|
20% Discount to BIS |
7.2.2(Dimensions (Maximum outside Diameter), IS 9537-2) |
- |
500 |
|
20% Discount to BIS |
7.3(Dimensions (Wall thickness), IS 9537-2) |
- |
500 |
|
20% Discount to BIS |
7.3.3(Uniformity of wall thickness, IS 9537-2) |
- |
500 |
|
20% Discount to BIS |
7.4(Screw threads, IS 9537-2) |
- |
500 |
|
20% Discount to BIS |
9.2(Mechanical Properties (Bending test), Cl. 9.3 of IS 9537-1) |
- |
1500 |
|
20% Discount to BIS |
9.3(Mechanical Properties (Compression Test), IS 9537-2) |
- |
1000 |
|
20% Discount to BIS |
13(External Influences, IS 9537-2) |
- |
4000 |
|
20% Discount to BIS |
6.1(Marking, IS 9537-2) |
- |
0 |
|
price in above |
|
Complete
|
19 Jul, 2024 |
06 Jun, 2027 |
INCLUDED W.E.F. 23-09-2020. For sizes 20mm to 50mm. |
17 |
IS 9968 : Part 1 (1988) |
Specification for elastomer insulatedcables: Part 1 for working voltages up to and including 1100 volts (First Revision) |
- |
-
|
22950 View breakup
Single Core For General Services = 22950 /-
Single Core For Heat Resisting Insulation = 22950 /-
Single Core For Silicon Insulation = 22950 /-
Single Core Sheathed Cable, General Services =22950.00
Single Core Sheathed Cable For Heat Resisting Insulation = 22950 /-
Separated Wire Before Stranding (If Provided = 625.00) Each Additional Per Core Charge = 2500.00/-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
13(CORE IDENTiFICATlON) |
- |
0 |
|
nil |
12.2(Insulation : Thickness of Insufatien) |
- |
325 |
|
20% Discount to BIS |
19.2(Sheath : Thickness of Sheath) |
- |
300 |
|
20% Discount to BIS |
20( Overall diameter) |
- |
625 |
|
20% Discount to BIS |
21. (a)(Persulphate tests (for copper)) |
- |
1250 |
|
20% Discount to BIS |
21. (b)(Annealing Test (for coper)) |
- |
625 |
|
20% Discount to BIS |
21. (c)( Tensile Test (for aluminium)) |
- |
625 |
|
20% Discount to BIS |
21. (d)( Wrapping Test (for aluminium)) |
- |
625 |
|
20% Discount to BIS |
21. (e)(Conductor Resistance ) |
- |
625 |
|
20% Discount to BIS |
21.1( Tensile strength ) |
- |
625 |
|
20% Discount to BIS |
22.1( Elongation) |
- |
625 |
|
20% Discount to BIS |
21.1(type test : Ageing In air oven) |
- |
3125 |
|
20% Discount to BIS |
21.1(type test : Ageing in air bomb) |
- |
3750 |
|
20% Discount to BIS |
21.1(type test : Ageing In oxygen
bomb) |
- |
3750 |
|
20% Discount to BIS |
21.1(type test : Tear resistance ) |
- |
1875 |
|
20% Discount to BIS |
22.2(type test :Insulauon resistance High voltage (water immersron ) test) |
- |
1875 |
|
20% Discount to BIS |
22.2(type test : Flammability test
( applicable to cables
finished With SE 3 and
SE 4 sheaths only)
) |
- |
1250 |
|
20% Discount to BIS |
|
Complete
|
19 Jul, 2024 |
06 Jun, 2027 |
INCLUDED W.E.F. 23-09-2020. |
18 |
IS 398 : Part 4 (1994) |
Aluminium conductors for overhead transmission purposes: Part 4 aluminium alloy stranded conductors (Aluminium - Magnesium - Silicon Type) - Specification (Third Revision) |
- |
-
|
8900 View breakup
For 3 Strands Rs. 1225.00
For 7 Strands Rs. 2500.00
For 19 Strands Rs. 3750.00
For 37 Strands Rs. 5750.00
For 61 Strands Rs. 7400.00
Separated Wire Before Stranding (If Provided) Rs. 1500.00
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
7.1 Table-1(Dimensional measurement of wires) |
- |
1250 |
|
20% Discount to BIS |
9.2 Table 3(Lay Ratio of stranded conductors) |
- |
1250 |
|
20% Discount to BIS |
12.2 Table 1(Breaking Load Test- Before Stranding) |
- |
1250 |
|
20% Discount to BIS |
12.2 Table 1(Breaking Load Test- After Stranding) |
- |
1250 |
|
20% Discount to BIS |
12.3 Table 1(Elongation Test- Before Stranding) |
- |
1250 |
|
20% Discount to BIS |
12.3 Table 1(Elongation Test- After Stranding) |
- |
1250 |
|
20% Discount to BIS |
7.2.2 Table-2, Table-4(Calculated resistance of Stranded Conductor) |
- |
1250 |
|
20% Discount to BIS |
|
Complete
|
19 Jul, 2024 |
06 Jun, 2027 |
- |
19 |
IS 398 : Part 1 (1996) |
Aluminium conductors for overhead transmission purposes - Specification: Part 1 aluminium stranded conductors (Third Revision) |
- |
-
|
5625 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
12.2, Table-1(Measurement of diameter of individual aluminium wire) |
- |
1250 |
|
20% Discount to BIS |
12.3, Table-1(Breaking load before stranding) |
- |
1250 |
|
20% Discount to BIS |
12.3, Table-1(Breaking load after stranding) |
- |
1250 |
|
20% Discount to BIS |
12.4(Wrapping test) |
- |
1250 |
|
20% Discount to BIS |
12.5, Table 1(Resistance test) |
- |
1250 |
|
20% Discount to BIS |
12.6, Table 3(Measurement of lay ratio) |
- |
1250 |
|
20% Discount to BIS |
|
Complete
|
19 Jul, 2024 |
06 Jun, 2027 |
- |
20 |
IS 1554 : Part 1 (1988) |
Specification for pvc insulated (Heavy Duty) electric cables: Part 1 for working voltages up to and including 1100 v (Third Revision) |
- |
-
|
32237 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
16.2(DETAILS OF TESTS : High Voltage Test at Room Temperature) |
- |
1875 |
|
20% Discount to BIS |
16.3.1(High Voltage Test ( Water Immersion Test ) : a.c. Test) |
- |
4375 |
|
20% Discount to BIS |
16.4(Flammability Test) |
- |
1250 |
|
20% Discount to BIS |
16.6(Flame Retardance Test on Single Cables) |
- |
3750 |
|
20% Discount to BIS |
16.5(Oxygen Index Test) |
- |
4375 |
|
20% Discount to BIS |
16.1(Temperature Index) |
- |
4375 |
|
20% Discount to BIS |
16.9(Test for Halogen Acid Gas Evolution) |
- |
3750 |
|
20% Discount to BIS |
15.1 a) 1)(Tests on conductor : Annealing test ( for copper )) |
- |
325 |
|
20% Discount to BIS |
15.1 a) 2)(Tensile test (for aluminium) - Before stranding ) |
- |
625 |
|
20% Discount to BIS |
15.1 a) 2)(Tensile test (for aluminium) - After stranding ) |
- |
625 |
|
20% Discount to BIS |
15.1 a) 3)(Tests on conductor : Wrapping test ( for aluminium )) |
- |
625 |
|
20% Discount to BIS |
15.1 a) 4)(Tests on conductor : Conductor resistance test) |
- |
625 |
|
20% Discount to BIS |
13.3(Armouring : Dimensions -Wire Diameter) |
- |
625 |
|
20% Discount to BIS |
13.6 a)(ARMOURING: Tensile Strength) |
- |
625 |
|
20% Discount to BIS |
13.6 b)(ARMOURING: Elongation ) |
- |
625 |
|
20% Discount to BIS |
13.6 c)(ARMOURING: Torsion Test (For round wire ) ) |
- |
625 |
|
20% Discount to BIS |
13.6 d)(ARMOURING: Winding Test(For formed wire)) |
- |
625 |
|
20% Discount to BIS |
13.6 e)(ARMOURING: Uniformity of zinc coating) |
- |
1250 |
|
20% Discount to BIS |
13.6 f)(ARMOURING: Mass of zinc coating ) |
- |
1250 |
|
20% Discount to BIS |
13.6 g)(ARMOURING: Resistivity) |
- |
1250 |
|
20% Discount to BIS |
9.2(INSULATION : Thickness of Insulation) |
- |
325 |
|
20% Discount to BIS |
9.3(INSULATION :Tolerance on Thickness of Insulation) |
- |
320 |
|
20% Discount to BIS |
14.4.1(Thickness of Outer Sheath : Unarmowed Cables) |
- |
325 |
|
20% Discount to BIS |
14.4.2(Thickness of Outer Sheath : Armoured Cables) |
- |
320 |
|
20% Discount to BIS |
15.1 d)1)(Phyaical tests for insulation : Tensile Test) |
- |
175 |
|
20% Discount to BIS |
15.1 d)1)(Phyaical tests for insulation : Elongation ) |
- |
150 |
|
20% Discount to BIS |
15.1 d)1)(Physical tests for sheath : Tensile stregth ) |
- |
175 |
|
20% Discount to BIS |
15.1 d)1)(Physical tests for sheath : Elongation ) |
- |
150 |
|
20% Discount to BIS |
15.1 d)2)(Phyaical tests for insulation- Ageing in air Oven : Tensile Test) |
- |
781 |
|
20% Discount to BIS |
15.1 d)2)(Phyaical tests for insulation - Ageing in air oven : Elongation ) |
- |
781 |
|
20% Discount to BIS |
15.1 d)2)(Phyaical tests for insulation - Ageing in air Oven : Tensile Variation ) |
- |
781 |
|
20% Discount to BIS |
15.1 d)2)(Phyaical tests for insulation- Ageing in air oven : Elongation Variation ) |
- |
781 |
|
20% Discount to BIS |
15.1 d)2)(Physical tests for outer sheath- Ageing in air oven : Tensile stregth ) |
- |
781 |
|
20% Discount to BIS |
15.1 d)2)(Physical tests for outer sheath -Ageing in air oven : Elongation ) |
- |
781 |
|
20% Discount to BIS |
15.1 d)2)(Physical tests for outer sheath- Ageing in air oven : Tensile stregth Variation ) |
- |
781 |
|
20% Discount to BIS |
15.1 d)2)(Physical tests for outer sheath -Ageing in air oven : Elongation Variation ) |
- |
781 |
|
20% Discount to BIS |
15.1 d)5)( Loss of mass in air oven- Insulation ) |
- |
1562 |
|
20% Discount to BIS |
15.1 d)5)( Loss of mass in air oven- sheath ) |
- |
1562 |
|
20% Discount to BIS |
15.1 d)3)(Phyaical tests for insulation : Shrinkage ) |
- |
320 |
|
20% Discount to BIS |
15.1 d)3)(Phyaical tests for Sheath : Shrinkage ) |
- |
325 |
|
20% Discount to BIS |
15.1 d)4)(Hot deformation : Insulation ) |
- |
600 |
|
20% Discount to BIS |
15.1 d)4)(Hot deformation : Sheath ) |
- |
650 |
|
20% Discount to BIS |
15.1 d)6)(Heat shock test- Insulation ) |
- |
325 |
|
20% Discount to BIS |
15.1 d)6)(Heat shock test- sheath ) |
- |
320 |
|
20% Discount to BIS |
15.1 d)7)(Thermal stability- insulation ) |
- |
1250 |
|
20% Discount to BIS |
15.1 d)7)(Thermal stability- Sheath ) |
- |
1250 |
|
20% Discount to BIS |
15.1 e)(Insulation resistance test : Volume Resistivity ) |
- |
900 |
|
20% Discount to BIS |
15.1 e)(Insulation resistance test : IR Constant ) |
- |
975 |
|
20% Discount to BIS |
15.4 a)(Cold bend test- Insulation ( Optional test)) |
- |
650 |
|
20% Discount to BIS |
15.4 a)(Cold bend test- Sheath ( Optional test)) |
- |
600 |
|
20% Discount to BIS |
15.4 b)(Cold impact test- Insulation ( Optional test)) |
- |
650 |
|
20% Discount to BIS |
15.4 b)(Cold impact test- Sheath ( Optional test)) |
- |
600 |
|
20% Discount to BIS |
|
Complete
|
19 Jul, 2024 |
06 Jun, 2027 |
Up to and including 400 sq. mm. |
21 |
IS 7098 : Part 1 (1988) |
Specification for crosslinked polyethylene insulated pvc sheathed cables: Part 1 for working voltages up to and including 1100 volts (First Revision) |
- |
-
|
31320 View breakup
Single Core Unsheathed Cable Rs. 28000/-
Single Core Sheathed Cable RS. 28000/-
Charges For FR Cable Rs.30600/-
Charges For FR-LSH Cable Rs.31320/-
Extra Charges For Armouring of Cable Rs.7500.00
Separated Wire Before Stranding (If Provided) Rs.900.00
Each Additional Core, Charge Per Core Rs. 2800.00
Optional Test (If Required) Rs. 1500.00
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
16.2(HIGH VOLTAGE TEST ) |
- |
1875 |
|
20% discount to BIS |
16.3(FLAMMABILITY TEST : Period of Burning ) |
- |
1250 |
|
20% discount to BIS |
16.3(FLAMMABILITY TEST : Unaffected length ) |
- |
1250 |
|
20% discount to BIS |
16.9(Oxygen Index Test) |
- |
4375 |
|
20% discount to BIS |
16.1(Flame Retardance Test on Single Cables) |
- |
4375 |
|
20% discount to BIS |
16.14(Temperature Index) |
- |
5625 |
|
20% discount to BIS |
16.13(Test for Halogen Acid Gas Evolution) |
- |
3750 |
|
20% discount to BIS |
15.1 f)(INSULATION RESISTANCE TEST : Volume resistivity ) |
- |
1875 |
|
20% discount to BIS |
15.1 a) i)(Annealing Test ( For copper wire ) ) |
- |
625 |
|
20% discount to BIS |
15.1 a) ii)(Tensile test (for aluminium) - Before stranding ) |
- |
625 |
|
20% discount to BIS |
15.1 a) ii)(Tensile test (for aluminium) - After stranding ) |
- |
625 |
|
20% discount to BIS |
15.1 a) iii)(Wrapping test (for aluminium)) |
- |
625 |
|
20% discount to BIS |
15.1 a) iv)(Resistance test - Main conductor) |
- |
625 |
|
20% discount to BIS |
15.1 a) iv)(Resistance test - Neutral conductor) |
- |
625 |
|
20% discount to BIS |
13.3(Armouring : Dimensions -Wire Diameter) |
- |
625 |
|
20% discount to BIS |
13.6 a)(ARMOURING: Tensile Strength) |
- |
625 |
|
20% discount to BIS |
13.6 b)(ARMOURING: Elongation ) |
- |
625 |
|
20% discount to BIS |
13.6 c)(ARMOURING: Torsion Test (For round wire ) ) |
- |
625 |
|
20% discount to BIS |
13.6 d)(ARMOURING: Winding Test(For formed wire)) |
- |
625 |
|
20% discount to BIS |
13.6 e)(ARMOURING: Uniformity of zinc coating) |
- |
1250 |
|
20% discount to BIS |
13.6 f)(ARMOURING: Mass of zinc coating ) |
- |
1250 |
|
20% discount to BIS |
13.6 g)(ARMOURING: Resistivity) |
- |
1250 |
|
20% discount to BIS |
9.2(Thickness of Insulation - Average) |
- |
300 |
|
20% discount to BIS |
9.3(Thickness of Insulation - Minimum) |
- |
300 |
|
20% discount to BIS |
14.3(Thickness of outer sheath - AVERAGE) |
- |
300 |
|
20% discount to BIS |
14.3(Thickness of outer sheath - minimum) |
- |
325 |
|
20% discount to BIS |
15.1 e) i) (Physical tests for outer sheath : Tensile stregth) |
- |
300 |
|
20% discount to BIS |
15.1 e) i) (Physical tests for outer sheath : Elongation) |
- |
325 |
|
20% discount to BIS |
15.1 d) ii) (Phyaical tests for insulation - Ageing in air Oven : Tensile Variation ) |
- |
1562 |
|
20% discount to BIS |
15.1 e) ii) (Physical tests for outer sheath -Ageing in air oven : Elongation Variation ) |
- |
1562 |
|
20% discount to BIS |
15.1 e) ii) (Physical tests for outer sheath- Ageing in air oven : Tensile stregth ) |
- |
1562 |
|
20% discount to BIS |
15.1 e) ii) (Physical tests for outer sheath -Ageing in air oven : Elongation ) |
- |
1562 |
|
20% discount to BIS |
15.1 e) iii) (Sheath: Loss of mass in air oven) |
- |
3125 |
|
20% discount to BIS |
15.1 e) iv) (Phyaical tests for Sheath : Shrinkage ) |
- |
625 |
|
20% discount to BIS |
15.1 e) iv) (Phyaical tests for Sheath : Shrinkage - Crack observed ) |
- |
625 |
|
20% discount to BIS |
15.1 e) v) (Sheath : Hot deformation) |
- |
1250 |
|
20% discount to BIS |
15.1 e) vi) (Sheath : Heat shock test) |
- |
625 |
|
20% discount to BIS |
15.1 e) vii) (Sheath : Thermalstability) |
- |
2500 |
|
20% discount to BIS |
|
Complete
|
19 Jul, 2024 |
06 Jun, 2027 |
• Up to and including 400 sq. mm. |
22 |
IS 14255 (1995) |
Aertal bunched cables - For working voltages up to and including 1100 Volts - Specification |
- |
-
|
16125 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
10.1 b) i)(Test on messenger conductor: Breaking load - IS 10810: Part 2) |
- |
625 |
|
20%discount to BIS |
10.1 b) ii)(Test on messenger conductor: Elongation test - Cl 11.3) |
- |
625 |
|
20%discount to BIS |
10.1 b) iii)(Test on messenger conductor: Resistance test - IS 10810: Part 5) |
- |
625 |
|
20%discount to BIS |
7.2( Thickness of insulation) |
- |
625 |
|
20%discount to BIS |
10.1 c) i)(Physical tests for XLPE Insulation:
Tensile strength - IS 10810: Part 7) |
- |
650 |
|
20%discount to BIS |
10.1 c) i)(Physical tests for XLPE Insulation:
elongation at break - IS 10810: part 7) |
- |
600 |
|
20%discount to BIS |
10.1 c) ii)(Ageing in air oven : Tensile strength variation - IS 10810:Part 11) |
- |
3125 |
|
20%discount to BIS |
10.1 c) ii)(Ageing in air oven : Elongation variation- IS 10810: Part 11) |
- |
3125 |
|
20%discount to BIS |
10.1 c) iii)(Hot set test: Elongation under load - IS 10810: Part 30) |
- |
2500 |
|
20%discount to BIS |
10.1 c) iii)(Hot set test: Permanent elongation (set) after cooling - IS 10810: Part 30) |
- |
2500 |
|
20%discount to BIS |
10.1 c) iv)(Shrinkage test : Shrinkage - 10810:Part 12) |
- |
1250 |
|
20%discount to BIS |
10.1 c) iv)(Shrinkage test : Crack Observed - 10810:Part 12) |
- |
1250 |
|
20%discount to BIS |
10.1 c) v)(Water ahsorption (Gravimetric) - IS 10810: Part 33 ) |
- |
5625 |
|
20%discount to BIS |
10.1 d) i)(Physical test for PE insulation:
Tensile strength - IS 10810: Part 7 ) |
- |
625 |
|
20%discount to BIS |
10.1 d) i)(Physical test for PE insulation: elongation at break - IS 10810: Part 7) |
- |
625 |
|
20%discount to BIS |
10.1 d) ii)(Melt flow index- IS 10810: Part 23) |
- |
1125 |
|
20%discount to BIS |
10.1 d) iv)(Vicat softening point -IS 10810: Part 22) |
- |
1000 |
|
20%discount to BIS |
10.1 f)(Insulation resistance (Volume resistivity) test a) volume resistivity at 27°C - IS 10810: Part 43) |
- |
1875 |
|
20%discount to BIS |
10.1 g)(High voltage test - IS10810:Part 45) |
- |
1875 |
|
20%discount to BIS |
10.1 a) ii)(Wrapping test - 10810: Part 3) |
- |
625 |
|
20%discount to BIS |
|
Complete
|
19 Jul, 2024 |
06 Jun, 2027 |
Included w.e.f.
08.11.2018. |
23 |
IS 398 : Part 2 (1996) |
Aluminium conductors for overhead transmission purposes - Specification: Part 2 aluminium conuuctors, galvanized steel - Reinforced (Third Revision) |
- |
-
|
8500 View breakup
For 7 Strands Rs. 5625.00
For 13 Strands Rs. 5785.00
Separated Wire Before Stranding (If Provided) Rs. 1500.00
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
8.1.1 & 13.2 Table-1 (mech)(Diameter of Aluminium Wires Before Stranding) |
- |
150 |
|
20% discount to BIS |
8.1.1 & 13.2 Table 2 (mech)(Diameter of Steel Wires Before Stranding) |
- |
150 |
|
20% discount to BIS |
8.1.1 & 13.2 Table-1 (mech)(Diameter of Aluminium Wires After Stranding) |
- |
150 |
|
20% discount to BIS |
8.1.1 & 13.2 Table 2 (mech)(Diameter of Steel Wires After Stranding) |
- |
175 |
|
20% discount to BIS |
13.3 Table 1 (mech)(Breaking Load of Aluminium Wires Before Stranding) |
- |
310 |
|
20% discount to BIS |
13.3 Table 2 (mech)(Breaking Load of Steel Wires Before Stranding) |
- |
310 |
|
20% discount to BIS |
13.3 Table 1 (mech)(Breaking Load of Aluminium Wires After Stranding) |
- |
320 |
|
20% discount to BIS |
13.3 Table 2 (mech)(Breaking Load of Steel Wires After Stranding) |
- |
310 |
|
20% discount to BIS |
13.4.1 (mech)(Ductility by Torsion Test before stranding) |
- |
300 |
|
20% discount to BIS |
13.4.1 (mech)(Ductility by Torsion Test after stranding) |
- |
300 |
|
20% discount to BIS |
13.4.2 (elec)(Ductility by Elongation Test before stranding) |
- |
300 |
|
20% discount to BIS |
13.4.2 (elec)(Ductility by Elongation Test after stranding) |
- |
350 |
|
20% discount to BIS |
13.5.1 (mech)(Wrapping Test Aluminium Wires Before Stranding) |
- |
150 |
|
20% discount to BIS |
13.5.1 (mech)(Wrapping Test Aluminium Wires After Stranding) |
- |
150 |
|
20% discount to BIS |
13.5.2 (mech)(Wrapping Test Galvanized Steel Wires Before Stranding) |
- |
150 |
|
20% discount to BIS |
13.5.2 (mech)(Wrapping Test Galvanized Steel Wires After Stranding) |
- |
175 |
|
20% discount to BIS |
13.6 (elec)(Resistance test-Aluminium wire before Stranding) |
- |
500 |
|
20% discount to BIS |
13.6 (elec)(Resistance test-Aluminium wire after stranding) |
- |
500 |
|
20% discount to BIS |
13.8 Table-4 (mech)(Lay Ratio- Aluminium Wire Outermost Layer) |
- |
625 |
|
20% discount to BIS |
13.8 Table-4 (mech)(Lay Ratio- Aluminium Wire Layer Immediately Beneath Outermost Layer) |
- |
625 |
|
20% discount to BIS |
13.8 Table-4 (mech)(Lay Ratio- Aluminium Wire Innermost Layer of Conductors with 3 Aluminium Wire Layers) |
- |
625 |
|
20% discount to BIS |
13.8 Table-4 (mech)(Lay Ratio- Steel Core (6 Wire Layer)) |
- |
625 |
|
20% discount to BIS |
13.7.2 (chem)(Mass of Zinc coating) |
- |
2125 |
|
20% discount to BIS |
13.7.2 (chem)(Uniformity of Zinc coating) |
- |
1500 |
|
20% discount to BIS |
|
Complete
|
19 Jul, 2024 |
06 Jun, 2027 |
• Up & including 100 Sq.mm |
24 |
IS 9537 : Part 3 (1983) |
Specification for conduits for electrical installations: Part 3 rigid plain conduits of insulating meterials |
- |
-
|
13750 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
6.1(Marking) |
- |
40 |
|
20% discount to BIS |
6.2(Durability of Marking as per 6.4 of IS: 9537 (Part 1)-1980) |
- |
35 |
|
20% discount to BIS |
7.1.1(Maximum and minimum outside diameter of socket) |
- |
50 |
|
20% discount to BIS |
7.2(Minimum inside diameter of conduit) |
- |
50 |
|
20% discount to BIS |
7.3(Length of conduit) |
- |
50 |
|
20% discount to BIS |
7.4(Unifomity of The wall Thickness) |
- |
74 |
|
20% discount to BIS |
9.2(Bending Test i) At Room Temp ii) At Low Temp (-5 ±2°C)) |
- |
177 |
|
20% discount to BIS |
9.3(Compression Test as per caluse 9.3 of IS: 9537 (Part 1)-1980) |
- |
150 |
|
20% discount to BIS |
9.4(Impact Test as per clause 9.4 of IS: 9537 (Part 1)-1980) |
- |
1635 |
|
20% discount to BIS |
9.5(Collapse Test as per clause 9.5 of IS: 9537 (Part 1)-1980) |
- |
285 |
|
20% discount to BIS |
10(Resistance to Heat -Ball presure test) |
- |
168 |
|
20% discount to BIS |
11(Resistance to burning as per clause 11 of IS: 9537 (Part 1)-1980) |
- |
150 |
|
20% discount to BIS |
12(Electrical Characteristics-Test for electric strength as per clause 12.1.1 of IS: 9537 (Part 1)-1980) |
- |
150 |
|
20% discount to BIS |
12(Electrical Characteristics-Insulation resistance test as per clause 12.1.2 of IS: 9537 (Part 1)-1980) |
- |
150 |
|
20% discount to BIS |
|
Complete
|
19 Jul, 2024 |
06 Jun, 2027 |
For sizes 20mm to 50mm. |
25 |
IS 616 (2017) |
Audio, video and similar electronic apparatus - Safety requirements (Fifth Revision) |
- |
-
|
35000 View breakup
Rs.35,000/- for Electronic Video games, Power adapters for audio, video & similar electronic apparatus.
Rs.35,000/- for Plasma/ LCD/ LED TV of screen size 32” & above, Plasma/ LCD/LED TVs of screen size up to 32”, Amplifiers with input power 2000W & above, Optical Disc Players with built in amplifier with input 2000W & above.
Rs.35000/- Video Camera, Webcam (Finished Products), Smart Speaker (With and without display), Bluetooth Speakers.
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
7(Heating under normal operating conditions) |
- |
6500 |
|
20% discount to BIS |
5(Marking and instructions) |
- |
650 |
|
20% discount to BIS |
8(Constructional requirements with regard to the protection against electric shock) |
- |
5200 |
|
20% discount to BIS |
9(Electric shock hazard under normal operating conditions) |
- |
5850 |
|
20% discount to BIS |
10(Insulation requirements) |
- |
7800 |
|
20% discount to BIS |
11(Fault conditions) |
- |
7150 |
|
20% discount to BIS |
12(Mechanical strength) |
- |
3250 |
|
20% discount to BIS |
13(CLEARANCES and CREEPAGE DISTANCES) |
- |
6500 |
|
20% discount to BIS |
15(TERMINALS) |
- |
1300 |
|
20% discount to BIS |
16(External flexible cords) |
- |
1300 |
|
20% discount to BIS |
17(Electrical connections and mechanical fixings) |
- |
3250 |
|
20% discount to BIS |
19(Stability and mechanical hazards) |
- |
3250 |
|
20% discount to BIS |
20(Resistance to fire) |
- |
6500 |
|
20% discount to BIS |
|
Complete
|
19 Jul, 2024 |
06 Jun, 2027 |
REVISED VERSON IS
616:2017. EXCLUSIONS: Ionizing radiation test (Cl.6.1), Laser radiation (Cl.6.2), Printed Boards(Cl.13.5), Component test (Cl.14), Mechanical strength of picture tubes & protection against the effect of implosion (Cl.18), Electrical Components (Cl.20.2.2), Internal wiring (Cl.20.2.3), Printed Boards (Cl.20.2.4), Components and parts (Cl.20.2.5), Fire Enclosure (Cl.20.3) |
26 |
IS 13252 : Part 1 (2010) |
Information technology equipment - Safety: Part 1 general requirements (Second Revision) |
- |
-
|
35000 View breakup
Laptop/ Notebook/ Tablet, Video monitors of screen size 32” & above, Printer, Plotter, Scanner, Visual display unit, Copying machines/ duplicators, Automatic data processing machine, Point of sale terminals & Cash Registers, Video monitors of screen size up to 32”, Smart Card Readers, Passport Reader, Banks for use in portable applications, Mobile phones, Wireless Keyboard/ Wired Keyboard, Set Top Box, Power adaptor for IT equipments, CCTV Cameras/ CCTV Recorders, Digital Camera. ADDITIONAL PRODUCTS INCLUDED W.E.F. 24-01-2022, mail processing machines / postage machines / franking machines / telephone answering machine= 35000/-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
1.6(Power interface .) |
- |
1300 |
|
breakup |
1.7(Markings and instructions) |
- |
650 |
|
breakup |
2.1(Protection from electric shock and energy hazards) |
- |
4550 |
|
breakup |
2.2(SELV circuits) |
- |
1625 |
|
breakup |
2.4(Limited current circuits) |
- |
1105 |
|
breakup |
2.5(Limited power sources .) |
- |
975 |
|
breakup |
2.6(Provisions for earthing and bonding) |
- |
1040 |
|
breakup |
2.7(Overcurrent and earth fault protection in primary circuits) |
- |
650 |
|
breakup |
2.8(Safety interlocks) |
- |
1625 |
|
breakup |
2.9(Electrical insulation) |
- |
3250 |
|
breakup |
2.10(Clearances, creepage distances and distances through insulation) |
- |
8255 |
|
breakup |
3.1(General) |
- |
3250 |
|
breakup |
3.2(Connection to a mains supply) |
- |
1300 |
|
breakup |
3.3(Wiring terminals for connection of external conductors) |
- |
1300 |
|
breakup |
3.4(Disconnection from the mains supply) |
- |
650 |
|
breakup |
3.5(Interconnection of equipment) |
- |
650 |
|
breakup |
4.1(Stability) |
- |
325 |
|
breakup |
4.2(Mechanical strength) |
- |
2080 |
|
breakup |
4.3(Design and construction) |
- |
650 |
|
breakup |
4.4(Protection against hazardous moving parts) |
- |
975 |
|
breakup |
4.5(Thermal requirements) |
- |
2990 |
|
breakup |
4.6(Openings in enclosures) |
- |
2925 |
|
breakup |
4.7(Resistance to fire) |
- |
2925 |
|
breakup |
5.1(Touch current and protective conductor curren) |
- |
845 |
|
breakup |
5.2(Electric strength) |
- |
1300 |
|
breakup |
5.3(Abnormal operating and fault conditions) |
- |
2600 |
|
breakup |
6.1(Protection of telecommunication network service persons, and users of other equipment connected to the network, from hazards in the equipment) |
- |
1300 |
|
breakup |
6.2(Protection of equipment users from overvoltages on networks telecommunication) |
- |
3055 |
|
breakup |
6.3(Protection of the telecommunication wiring system from overheating) |
- |
2600 |
|
breakup |
7.1(General) |
- |
650 |
|
breakup |
7.2(Protection of cable distribution system service persons, and users of other equipment connected to the system, from hazardous voltages in the equipment) |
- |
650 |
|
breakup |
7.3(Protection of equipment users from overvoltages on the cable distribution system) |
- |
2275 |
|
breakup |
7.4(Insulation between primary circuits and cable distribution systems) |
- |
2600 |
|
breakup |
|
Complete
|
19 Jul, 2024 |
06 Jun, 2027 |
EXCLUSIONS: Component (Cl.1.5), Safety Interlocks: Moving parts (Cl.2.8.5), Switches & Relays (Cl.2.8.7),Semiconductor Devices (Opto-coupler test) (Cl.2.10.5.4), Insulation in wound components (Cl.2.10.5.11), Wire in wound components (Cl. 2.10.5.12), Tests for semiconductor devices & for cemented joints (Cl. 2.10.11), Cathode Ray Tube (Cl.4.2.8), Batteries (cl.4.3.8); Radiation (Cl.4.3.13), Electromechanical components (Cl. 5.3.5), Insulating winding wires (Annex U), Evaluation of IC current limiters (Annex CC). |
27 |
IS 694 (2010) |
Polyvinyl chloride insulated unsheathed and sheathed cables/cords with rigid and flexible conductor for rated voltages up to and including 450/750 v (Fourth Revision) |
- |
-
|
18750 View breakup
Single Core Unsheathed Cable Rs. 7500.00
Single Core Sheathed Cable RS. 10300.00 Extra
Charges For Outdoor Use Cable Rs.5625.00
Extra Charges For Low
Temperature Use Cable Rs.2250.00
Charges For FR Cable Rs. 15000.00
Charges For FR-LSH Cable Rs.18750.00
Separated Wire Before Stranding (If Provided) Rs.900.00
Each Additional Core, Charge Per Core Rs. 2800.00
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
10.9(Additional ageing test (OU cables only) -HV test (at 60±3oC)) |
- |
3125 |
|
20%discount to BIS |
10.4(Flammability test- Unaffected portion) |
- |
625 |
|
20%discount to BIS |
10.4(Flammability test-Burning after flame removal) |
- |
625 |
|
20%discount to BIS |
10.1(HV (water immersion)) |
- |
1875 |
|
For AC TEST
20%discount to BIS |
10.1(HV (water immersion)) |
- |
4375 |
|
FOR DC TEST
20%discount to BIS |
10.5(Oxygen index) |
- |
4375 |
|
20%discount to BIS |
10.7(Temperature index) |
- |
4375 |
|
20%discount to BIS |
10.6(Halogen evolution) |
- |
3750 |
|
20%discount to BIS |
10.2(HV (room temperature)) |
- |
1875 |
|
20%discount to BIS |
4.1(Annealing test (for copper)) |
- |
625 |
|
20%discount to BIS |
4.1(Tensile test (for Al)- After Stranding) |
- |
625 |
|
20%discount to BIS |
4.1(Tensile test (for Al)-Before Stranding) |
- |
625 |
|
20%discount to BIS |
4.1(Wrapping test (for Al)) |
- |
625 |
|
20%discount to BIS |
4.2(Conductor resistance test) |
- |
625 |
|
20%discount to BIS |
10.11(Per sulphate test (for tinned Cu cable only)) |
- |
1250 |
|
20%discount to BIS |
9(Overall dimensions) |
- |
625 |
|
20%discount to BIS |
5.3(Thickness of Insulation) |
- |
625 |
|
20%discount to BIS |
Table 1 iii) c) 3)(Tensile strength (After ageing)) |
- |
625 |
|
20%discount to BIS |
Table 1 iii) d) 6)(Hot deformation -Indentation depth - Sheath ) |
- |
1875 |
|
20%discount to BIS |
Table 1 iii) c) 6)(Hot deformation - Indentation depth- Insulation) |
- |
1875 |
|
20%discount to BIS |
Table 1 iii) d) 9)(Cold impact for sheath) |
- |
1250 |
|
20%discount to BIS |
Table 1 iii) c) 9)(Cold impact for insulation) |
- |
625 |
|
20%discount to BIS |
Table 1 iii) d) 5)(Heat shock-Sheath ) |
- |
625 |
|
20%discount to BIS |
Table 1 iii) c) 5)(Heat shock-Insulation ) |
- |
625 |
|
20%discount to BIS |
Table 1 iii) d) 7)(Thermal stability- Sheath ) |
- |
2500 |
|
20%discount to BIS |
Table 1 iii) c) 7)(Thermal stability- Insulation ) |
- |
2500 |
|
20%discount to BIS |
Table 1 iii) d) 4)(Shrinkage- Sheath ) |
- |
625 |
|
20%discount to BIS |
Table 1 iii) c) 4)(Shrinkage-Insulation) |
- |
625 |
|
20%discount to BIS |
Table 1 iii) d) 2)(Loss of mass- Sheath ) |
- |
3125 |
|
20%discount to BIS |
Table 1 iii) c) 2)(Loss of mass- Insulation ) |
- |
3125 |
|
20%discount to BIS |
Table 1 iii) d) 8)(Cold bend for sheath) |
- |
1250 |
|
20%discount to BIS |
Table 1 iii) c) 8)(Cold bend for insulation) |
- |
625 |
|
20%discount to BIS |
Table 1 iii) c) 1)(Elongation (Without ageing)) |
- |
625 |
|
20%discount to BIS |
Table 1 iii) c) 1)(Tensile strength (Without ageing)) |
- |
625 |
|
20%discount to BIS |
|
Complete
|
19 Jul, 2024 |
06 Jun, 2027 |
Following Additional
• Up to and including 400 sq. mm. |