1 |
IS 16102 : Part 1 (2012) |
Self - Ballasted led lamps for general lighting services: Part 1 safety requirements |
- |
-
|
49500 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
5(Marking) |
- |
2000 |
|
NIL |
6(Interchangeability) |
- |
5000 |
|
NIL |
7(Protection against accidental contact with live parts) |
- |
5000 |
|
NIL |
8(Insulation Resistance and Electric Strength) |
- |
5000 |
|
NIL |
9(MECHANICAL STRENGTH) |
- |
5000 |
|
NIL |
10(cap temperature) |
- |
8000 |
|
NIL |
11(Resistance to Heat) |
- |
5000 |
|
NIL |
12(Resistance to Flame and Ignition) |
- |
8000 |
|
NIL |
13(Fault conditions) |
- |
6000 |
|
NIL |
14(Creepage distance and clearances) |
- |
3000 |
|
NIL |
|
Complete
|
|
17 Sep, 2024 |
- |
2 |
IS 16046 : Part 1 (2018) |
Secondary Cells and Batteries Containing Alkaline or Other Non-Acid Electrolytes ” Safety Requirements for Portable Sealed Secondary Cells and for Batteries Made from Them for Use in Portable Applications Part 1 Nickel Systems ( Second Revision ) |
- |
-
|
62500 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
4(Parameter Measurement Tolerances) |
- |
5000 |
|
Nil |
5(General Safety Considerations) |
- |
1000 |
|
Nil |
5.1(General) |
- |
1000 |
|
Nil |
5.2(Insulation and Wiring) |
- |
1000 |
|
Nil |
5.3(Venting) |
- |
1000 |
|
Nil |
5.4(Temperature, Voltage and Current Management) |
- |
1000 |
|
Nil |
5.5(Terminal Contacts) |
- |
1000 |
|
Nil |
5.6(Assembly of Cells into batteries) |
- |
1000 |
|
Nil |
5.7(Quality Plan) |
- |
1000 |
|
Nil |
6(Tyoe Test amd Sample Size) |
- |
2000 |
|
Nil |
7(Specific requirements and tests) |
- |
2000 |
|
Nil |
7.1(Charging procedure for test purposes) |
- |
1000 |
|
Nil |
7.2(Intended Use) |
- |
5000 |
|
Nil |
7.3(Reasonably foreseeable misuse) |
- |
30000 |
|
Nil |
8(Information for safety) |
- |
1000 |
|
Nil |
8.1(General) |
- |
1000 |
|
Nil |
8.2(Small Cell and battery safety information) |
- |
1500 |
|
Nil |
9(Marking) |
- |
1000 |
|
Nil |
9.1(Cell Marking) |
- |
1000 |
|
Nil |
9.2(Battery Marking) |
- |
1000 |
|
Nil |
9.3(Caution for ingestion of small cells and batteries) |
- |
1000 |
|
Nil |
9.4(Other information) |
- |
1000 |
|
Nil |
10(Packaging) |
- |
1000 |
|
Nil |
|
Complete
|
|
17 Sep, 2024 |
- |
3 |
IS 16046 : Part 2 (2018) |
Secondary Cells and Batteries Containing Alkaline or Other Non-Acid Electrolytes ” Safety Requirements for Portable Sealed Secondary Cells and for Batteries Made from Them for Use in Portable Applications Part 2 Lithium Systems ( Second Revision ) |
- |
-
|
62500 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
4(Parameter Measurement Tolerances) |
- |
5000 |
|
Nil |
5(General Safety Considerations) |
- |
1000 |
|
Nil |
5.1(General) |
- |
1000 |
|
Nil |
5.2(Insulation and Wiring) |
- |
1000 |
|
Nil |
5.3(Venting) |
- |
1000 |
|
Nil |
5.4(Temperature, Voltage and Current Management) |
- |
1000 |
|
Nil |
5.6(Assembly of Cells into batteries) |
- |
1000 |
|
Nil |
5.7(Quality Plan) |
- |
1000 |
|
Nil |
5.8(Battery Safety Components) |
- |
1000 |
|
Nil |
6(Type Test and Sample Size) |
- |
2000 |
|
Nil |
7(Specific requirements and tests) |
- |
1000 |
|
Nil |
7.1(Charging procedure for test purposes) |
- |
1000 |
|
Nil |
7.2(Intended Use) |
- |
5000 |
|
Nil |
7.3(Reasonably foreseeable misuse) |
- |
30000 |
|
Nil |
8(Information for safety) |
- |
1000 |
|
Nil |
8.1(General) |
- |
1000 |
|
Nil |
8.2(Small Cell and battery safety information) |
- |
1500 |
|
Nil |
9(Marking) |
- |
1000 |
|
Nil |
9.1(Cell Marking) |
- |
1000 |
|
Nil |
9.2(Battery Marking) |
- |
1000 |
|
Nil |
9.3(Caution for ingestion of small cells and batteries) |
- |
1000 |
|
Nil |
9.4(Other information) |
- |
1000 |
|
Nil |
10(Packaging) |
- |
1000 |
|
Nil |
5.5(Terminal Contacts) |
- |
1000 |
|
Nil |
|
Complete
|
|
17 Sep, 2024 |
- |
4 |
IS 15885 : Part 2 : Sec 13 (2012) |
Safety of lamp controlgear: Part 2 particular requirements: Sec 13 d.c. or a.c. supplied electronic controlgear for led modules |
- |
-
|
52500 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
7(Marking) |
- |
2000 |
|
Nil |
8(Protection against accidental contact with live parts) |
- |
5000 |
|
Nil |
9(Terminals) |
- |
5000 |
|
Nil |
10(PROVISION FOR EARTHING) |
- |
3000 |
|
Nil |
11(MOISTURE RESISTANCE) |
- |
5000 |
|
Nil |
12(Electric Strength) |
- |
5000 |
|
Nil |
13(Thermal endurance test for winding of ballasts) |
- |
5000 |
|
Nil |
14(Fault conditions) |
- |
8000 |
|
Nil |
15(Transformer heating) |
- |
5000 |
|
Nil |
16(Construction) |
- |
5000 |
|
Nil |
17(Creepage distance and clearances) |
- |
3000 |
|
Nil |
18(Screws, current carrying parts and connections) |
- |
5000 |
|
Nil |
19(Resistance to heat, fire and tracking) |
- |
5000 |
|
Nil |
20(Resistance to corrosion) |
- |
3000 |
|
Nil |
|
Complete
|
|