BCH Electric Limited, Faridabad

20/4, Mathura road, Faridabad, Faridabad, Haryana, 121006
9891014805 sushil.kumar@bchindia.com
Scope List
Reset
8 Results
S.No. Indian Standard No. Product Grade / Type / Size / Designation etc. Testing Charges (Excl. Of Taxes) Validity Date Remark
1 IS/IEC 60947 : Part 5 : Sec 1 (2009) Low - Voltage switchgear and controlgear: Part 5 control circuit devices and switching elements: Sec 1 electromechanical control circuit devices (First Revision) Limit Switch, Foot Switch, Push Button, Control relay 1205000 View breakup
-
05 Jun, 2028 -
-
2 IS/IEC 60947 : PART 3 (2020) Low-Voltage Switchgear and Controlgear: Part 3 Switches Disconnectors Switch-Disconnectors and Fuse-Combination Units I MCB SOLATOR, MCCB ISOLATOR SWITCH, SWITCH DISCONNECTORS, FUSE COMBINATION 820000 View breakup
-
05 Jun, 2028 -
Included w.e.f 23.06.2025 Restricted only for Sequence I, II, V & VI. Excluding Cl. 8.3 (Electromagnetic compatibility (EMC)), Cl. 9.3.6 (short-circuit performance capability), Cl. 9.3.7 (conditional short-circuit current), Cl. 9.3.4 (Performance under short-circuit conditions), Cl. 9.4 (EMC tests), 9.3.9.2 (Determination of critical load current), 8.2.8 (Critical load current performance: DC equipment)
3 IS/IEC 60947 : Part 5 : Sec 1 (2016) Low-Voltage Switchgear And Control Gear : Part 5-1 Control Circuit Devices And Switching Elements Electromechanical Control Circuit Devices Limit switch, Foot switch, control relay, push button, auxiliary Device 2000000 View breakup
-
05 Jun, 2028 -
Included w.e.f 23.06.2025 Restricted only for Sequence I, II, III, IV, V & VI. Excluding Cl. 7.1.3 (Current-carrying parts and their connections), Cl. 7.3 (Electromagnetic compatibility (EMC)), 8.2.1.1.2 (Flammability, hot wire ignition and arc ignition tests (on materials)) Cl. 8.3.4 (Performance under conditional short-circuit current), Cl. 9.3.4 (Performance under short-circuit conditions), Cl. 8.4 (EMC tests), G.8.2.5 (Bend test), J.8.4 Shock and vibration
4 IS/IEC 60947 : Part 4 : Sec 1 (2018) Low-Voltage switchgear and controlgear : Part 4-1 Contactors and motor starters electromechanical contactors and motor-Starters Contactor & Starter 1100000 View breakup
-
05 Jun, 2028 -
Included w.e.f 23.06.2025 Restricted only for Sequence I, II, IV & V. Excluding Cl. 8.1.2.3 (Test based on flammability category). Cl. 8.3 (EMC), Cl. 9.3.4 (Performance under short-circuit conditions), Cl. 9.4 (EMC tests), Q.5.3 (Selectivity determined by test)
5 IS/IEC 60529 (2001) Degrees of protection provided by enclosures (IP Code) Motor starter Starter, Enclosure 170000 View breakup
-
05 Jun, 2028 -
-
6 IS/IEC 60947 : Part 4 : Sec 1 (2012) Low - Voltage switchgear and controlgear: Part 4 contactors and motor - Starters: Sec 1 electromechanical contactors and motor - Starters (First Revision) Starter, Contactor, Thermal Overload Relay 3260000 View breakup
-
05 Jun, 2028 -
Exclusion: 9.3.4 (Performance under short-circuit conditions), 9.4.2 (Immunity), 9.4.1 (General), 9.4.3 (Emission)
7 IS/IEC 60947 : PART 3 (2012) Low - Voltage switchgear and controlgear: Part 3 switches, disconnectors, switch disconnectors and fuse - Combination units (First Revision) SD F1/F2/F3 & SDF/FD/SFU 32-200A 3410000 View breakup
-
05 Jun, 2028 -
Exclusion: 8.3.5.1 ( Short-time withstand current test), 8.3.5.2 (Short-circuit making capacity test)
8 IS/IEC 60947 : Part 2 (2016) Low - Voltage switchgear and controlgear: Part 2 circuit - Breakers (First Revision) F1-TUMU/F2-TMTU/F3-TMTU/F3-LSIG/F2-LSIG MCCB 1674000 View breakup
-
05 Jun, 2028 -
Exclusion: 8.3.8.4 (rated service short circuit breaking capacity (sequence VI)), 8.3.4.3 (verification of operational performance capability (sequence II)), 8.3.4.1 (General), 8.3.8.4 (Rated service short-circuit breaking capacity*), 8.3.7.7 (Short-circuit at ultimate short-circuit breaking capacity), 8.3.8.3 (rated short time withstand current (sequence VI)), 8.3.7.6 ((stage 2) short circuit at 1.1 time the take-over current (sequence V)), 8.3.8.3 (rated short time withstand current (sequence VI)), 8.3.6.3 (rated short circuit withstand current (sequence IV)), 8.3.7.6 ((stage 2) short circuit at 1.1 time the take-over current (sequence V)), 8.3.6.3 (rated short circuit withstand current (sequence IV)), 8.3.5.3 (rated short circuit breaking capacity (sequence III)), 8.3.7.2 ((stage 1) short circuit at the selectivity limit current (sequence V)), 8.3.5.3 (Rated ultimate short-circuit breaking capacity), Annex N (Electromagnetic compatibility (EMC)), Annex O (Electromagnetic compatibility (EMC)), 7.3 Annexure J Table J.1 (Electrostatic discharges), 8.3.9 (Critical d.c. load current test), Cl.8.5 (Annex Q of IS/IEC 60947-1) (Special tests)

Designed, Developed and Maintained by: