| 1 |
IS/IEC 62368 : Part 1 (2023) |
Audio Video Information and Communication Technology Equipment - Part 1: Safety Requirements (Second Revision) |
- |
200000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl-4.1(General- materials, components) |
- |
5000 |
|
20% Discount to BIS |
| Cl-4.2(Energy source classifications) |
- |
5000 |
|
20% Discount to BIS |
| Cl-4.3(Protection against energy sources) |
- |
5000 |
|
20% Discount to BIS |
| Cl-4.4(Safeguards) |
- |
0 |
|
-- |
| Cl-4.5(Explosion) |
- |
0 |
|
-- |
| Cl-4.6(Fixing of conductors and conductive parts) |
- |
5000 |
|
20% Discount to BIS |
| Cl-4.7(Equipment for direct insertion into mains socket-outlets) |
- |
5000 |
|
20% Discount to BIS |
| Cl-4.8(Equipment containing coin or button cell batteries) |
- |
10000 |
|
20% Discount to BIS |
| Cl-4.9(Likelihood of fire or shock due to entry of conductive objects) |
- |
5000 |
|
20% Discount to BIS |
| Cl-4.10(Components requirements) |
- |
10000 |
|
20% Discount to BIS |
| Cl-5.1(General- Electrically-caused injury) |
- |
5000 |
|
20% Discount to BIS |
| Cl-5.2(Classification and limits of electrical energy sources) |
- |
15000 |
|
20% Discount to BIS |
| Cl-5.3(Protection against electrical energy sources) |
- |
15000 |
|
20% Discount to BIS |
| Cl-5.4(Insulation materials and requirements) |
- |
40000 |
|
20% Discount to BIS |
| Cl-5.5(Components as safeguards) |
- |
15000 |
|
20% Discount to BIS |
| Cl-5.6(Protective conductor) |
- |
15000 |
|
20% Discount to BIS |
| Cl-5.7(Prospective touch voltage, touch current and protective conductor current) |
- |
20000 |
|
20% Discount to BIS |
| Cl-5.8(Backfeed safeguard in battery backed up supplies) |
- |
25000 |
|
20% Discount to BIS |
| Cl-6.1(General- Electrically-caused fire) |
- |
5000 |
|
20% Discount to BIS |
| Cl-6.2(Classification of power sources and potential ignition sources) |
- |
15000 |
|
20% Discount to BIS |
| Cl-6.3(Safeguards against fire under normal operating conditions and abnormal operating conditions) |
- |
20000 |
|
20% Discount to BIS |
| Cl-6.4(Safeguards against fire under single fault conditions) |
- |
20000 |
|
20% Discount to BIS |
| Cl-6.5(Internal and external wiring) |
- |
5000 |
|
20% Discount to BIS |
| Cl-7.1(General- Injury caused by hazardous substances) |
- |
0 |
|
-- |
| Cl-7.2(Reduction of exposure to hazardous substances) |
- |
0 |
|
-- |
| Cl-7.3(Ozone exposure) |
- |
0 |
|
-- |
| Cl-7.4(Use of personal safeguards or personal protective equipment (PPE) |
- |
0 |
|
-- |
| Cl-7.5(Use of instructional safeguards and instructions) |
- |
0 |
|
-- |
| Cl-8.1(General- Mechanically-caused injury) |
- |
5000 |
|
20% Discount to BIS |
| Cl-8.2(Mechanical energy source classifications) |
- |
10000 |
|
20% Discount to BIS |
| Cl-8.3(Safeguards against mechanical energy sources) |
- |
15000 |
|
20% Discount to BIS |
| Cl-8.4(Safeguards against parts with sharp edges and corners) |
- |
15000 |
|
20% Discount to BIS |
| Cl-8.5(Safeguards against moving parts) |
- |
15000 |
|
20% Discount to BIS |
| Cl-8.6(Stability of equipment) |
- |
15000 |
|
20% Discount to BIS |
| Cl-8.7(Equipment mounted to a wall, ceiling or other structure) |
- |
20000 |
|
20% Discount to BIS |
| Cl-8.8(Handle strength) |
- |
10000 |
|
20% Discount to BIS |
| Cl-8.9(Wheels or casters attachment requirements) |
- |
10000 |
|
20% Discount to BIS |
| Cl-8.10(Carts, stands, and similar carriers) |
- |
10000 |
|
20% Discount to BIS |
| Cl-8.11(Mounting means for slide-rail mounted equipment (SRME)) |
- |
15000 |
|
20% Discount to BIS |
| Cl-9.1(General-Thermal burn injury) |
- |
5000 |
|
20% Discount to BIS |
| Cl-9.2(Thermal energy source classifications) |
- |
30000 |
|
20% Discount to BIS |
| Cl-9.3(Touch temperature limits) |
- |
10000 |
|
20% Discount to BIS |
| Cl-9.4(Safeguards against thermal energy sources) |
- |
5000 |
|
20% Discount to BIS |
| Cl-9.5(Requirements for safeguards) |
- |
5000 |
|
20% Discount to BIS |
| Cl-9.6(Requirements for wireless power transmitters) |
- |
20000 |
|
20% Discount to BIS |
| Cl-10.1(General-Radiation) |
- |
0 |
|
-- |
| Cl-10.2(Radiation energy source classifications) |
- |
0 |
|
-- |
| Cl-10.3(Safeguards against laser radiation) |
- |
0 |
|
-- |
| Cl-10.4("Safeguards against optical radiation from lamps and lamp systems
(including LED types)") |
- |
0 |
|
-- |
| Cl-10.5(Safeguards against X-radiation) |
- |
0 |
|
-- |
| Cl-10.6(Safeguards against acoustic energy sources) |
- |
0 |
|
-- |
| Annex A(Examples of equipment within the scope of this document) |
- |
5000 |
|
20% Discount to BIS |
| Annex B(General- Normal operating condition tests, abnormal operating condition tests and single fault condition tests) |
- |
5000 |
|
20% Discount to BIS |
| Annex B-2(Normal operating conditions) |
- |
20000 |
|
20% Discount to BIS |
| Annex B-3(Simulated abnormal operating conditions) |
- |
25000 |
|
20% Discount to BIS |
| Annex B-4(Simulated single fault conditions) |
- |
30000 |
|
20% Discount to BIS |
| Annex C-1(Protection of materials in equipment from UV radiation) |
- |
0 |
|
-- |
| Annex C-2(UV light conditioning test) |
- |
0 |
|
-- |
| Annex D-1(Impulse test generators) |
- |
20000 |
|
20% Discount to BIS |
| Annex D-2(Antenna interface test generator) |
- |
0 |
|
-- |
| Annex D-3(Electronic pulse generator) |
- |
20000 |
|
20% Discount to BIS |
| Annex E-1(Electrical energy source classification for audio signals) |
- |
5000 |
|
20% Discount to BIS |
| Annex E-2(Audio signals used during test) |
- |
10000 |
|
20% Discount to BIS |
| Annex E-3(Operating conditions of equipment containing an audio amplifier) |
- |
10000 |
|
20% Discount to BIS |
| Annex F-1(General-Equipment markings, instructions, and instructional safeguards) |
- |
15000 |
|
20% Discount to BIS |
| Annex F-2(Letter symbols and graphical symbols) |
- |
5000 |
|
20% Discount to BIS |
| Annex F-3(Equipment markings) |
- |
10000 |
|
20% Discount to BIS |
| Annex F-4(Instructions) |
- |
10000 |
|
20% Discount to BIS |
| Annex F-5(Instructional safeguards) |
- |
5000 |
|
20% Discount to BIS |
| Annex G-1(Switches) |
- |
15000 |
|
20% Discount to BIS |
| Annex G-2(Relays) |
- |
15000 |
|
20% Discount to BIS |
| Annex G-3(Protective devices) |
- |
20000 |
|
20% Discount to BIS |
| Annex G-4(Connectors) |
- |
15000 |
|
20% Discount to BIS |
| Annex G-5(Wound components) |
- |
25000 |
|
20% Discount to BIS |
| Annex G-6(Wire insulation) |
- |
15000 |
|
20% Discount to BIS |
| Annex G-7(Mains power supply cords and interconnection cables) |
- |
0 |
|
-- |
| Annex G-8(Varistors) |
- |
10000 |
|
20% Discount to BIS |
| Annex G-9(Integrated circuit (IC) current limiters) |
- |
0 |
|
-- |
| Annex G-10(Resistors) |
- |
20000 |
|
20% Discount to BIS |
| Annex G-11(Capacitors and RC units) |
- |
15000 |
|
20% Discount to BIS |
| Annex G-12(Optocouplers) |
- |
15000 |
|
20% Discount to BIS |
| Annex G-14(Coatings on component terminals) |
- |
20000 |
|
20% Discount to BIS |
| Annex G-15(Pressurized liquid filled components or LFC assemblies) |
- |
0 |
|
-- |
| Annex G-16(IC that includes a capacitor discharge function (ICX)) |
- |
0 |
|
20% Discount to BIS |
| Annex H-1(General- Criteria for telephone ringing signals) |
- |
5000 |
|
20% Discount to BIS |
| Annex H-2(Method A) |
- |
25000 |
|
20% Discount to BIS |
| Annex H-3(Method B) |
- |
25000 |
|
20% Discount to BIS |
| Annex I(Overvoltage categories (see IEC 60364-4-44)) |
- |
5000 |
|
20% Discount to BIS |
| Annex J-1(General-Insulated winding wires for use without interleaved insulation) |
- |
0 |
|
-- |
| Annex J-2(Type tests) |
- |
0 |
|
-- |
| Annex J-3(Testing during manufacturing) |
- |
0 |
|
-- |
| Annex K-1(General- Safety interlocks) |
- |
5000 |
|
20% Discount to BIS |
| Annex K-2(Components of the safety interlock safeguard mechanism) |
- |
10000 |
|
20% Discount to BIS |
| Annex K-3(Inadvertent change of operating mode) |
- |
15000 |
|
20% Discount to BIS |
| Annex K-4(Interlock safeguard override) |
- |
15000 |
|
20% Discount to BIS |
| Annex K-5(Fail-safe) |
- |
15000 |
|
20% Discount to BIS |
| Annex K-6(Mechanically operated safety interlocks) |
- |
15000 |
|
20% Discount to BIS |
| Annex K-7(Interlock circuit isolation) |
- |
15000 |
|
20% Discount to BIS |
| Annex G-13(Printed boards) |
- |
20000 |
|
20% Discount to BIS |
| Annex L-1(General requirements) |
- |
20000 |
|
20% Discount to BIS |
| Annex L-2(Permanently connected equipment) |
- |
15000 |
|
20% Discount to BIS |
| Annex L-3() |
- |
15000 |
|
20% Discount to BIS |
| Annex L-4(Single-phase equipment) |
- |
15000 |
|
20% Discount to BIS |
| Annex L-5(Three-phase equipment) |
- |
15000 |
|
20% Discount to BIS |
| Annex L-6(Switches as disconnect devices) |
- |
15000 |
|
20% Discount to BIS |
| Annex L-7(Plugs as disconnect devices) |
- |
15000 |
|
20% Discount to BIS |
| Annex L-8(Multiple power sources) |
- |
15000 |
|
20% Discount to BIS |
| Annex L-9(Compliance criteria) |
- |
15000 |
|
20% Discount to BIS |
| Annex M-1(General requirements) |
- |
15000 |
|
20% Discount to BIS |
| Annex M-2(Safety of batteries and their cells) |
- |
20000 |
|
20% Discount to BIS |
| Annex M-3(Protection circuits for batteries provided within the equipment) |
- |
25000 |
|
20% Discount to BIS |
| Annex M-4(Additional safeguards for equipment containing a secondary lithium battery) |
- |
0 |
|
-- |
| Annex M-5(Risk of burn due to short-circuit during carrying) |
- |
20000 |
|
20% Discount to BIS |
| Annex M-6(Safeguards against short-circuits) |
- |
20000 |
|
20% Discount to BIS |
| Annex M-7(Risk of explosion from lead acid and NiCd batteries) |
- |
0 |
|
- |
| Annex M-8("Protection against internal ignition from external spark sources of
rechargeable batteries with aqueous electrolyte") |
- |
0 |
|
- |
| Annex M-9(Preventing electrolyte spillage) |
- |
20000 |
|
20% Discount to BIS |
| Annex M-10(Instructions to prevent reasonably foreseeable misuse) |
- |
10000 |
|
20% Discount to BIS |
| Annex N(Electrochemical potentials (V)) |
- |
10000 |
|
20% Discount to BIS |
| Annex O(Measurement of creepage distances and clearances) |
- |
10000 |
|
20% Discount to BIS |
| Annex P-1(General-Safeguards against conductive objects) |
- |
5000 |
|
20% Discount to BIS |
| Annex P-2(Safeguards against entry or consequences of entry of a foreign object) |
- |
5000 |
|
20% Discount to BIS |
| Annex P-3(Safeguards against spillage of internal liquids) |
- |
5000 |
|
20% Discount to BIS |
| Annex P-4(Metallized coatings and adhesives securing parts) |
- |
5000 |
|
20% Discount to BIS |
| Annex Q-1(Limited power source) |
- |
10000 |
|
20% Discount to BIS |
| Annex Q-2(Test for external circuits – paired conductor cable) |
- |
10000 |
|
20% Discount to BIS |
| Annex R(Limited short-circuit test) |
- |
0 |
|
-- |
| Annex S-1(Flammability test for fire enclosure and fire barrier materials of equipment where the steady state power does not exceed 4 000 W) |
- |
5000 |
|
20% Discount to BIS |
| Annex S-2(Flammability test for fire enclosure and fire barrier integrity) |
- |
15000 |
|
20% Discount to BIS |
| Annex S-3(Flammability tests for the bottom of a fire enclosure) |
- |
20000 |
|
20% Discount to BIS |
| Annex S-4(Flammability classification of materials) |
- |
15000 |
|
20% Discount to BIS |
| Annex S-5(Flammability test for fire enclosure materials of equipment with a steady state power exceeding 4 000 W) |
- |
15000 |
|
20% Discount to BIS |
| Annex T-1(General-Mechanical strength tests) |
- |
10000 |
|
20% Discount to BIS |
| Annex T-2(Steady force test, 10 N) |
- |
10000 |
|
20% Discount to BIS |
| Annex T-3(Steady force test, 30 N) |
- |
10000 |
|
20% Discount to BIS |
| Annex T-4(Steady force test, 100 N) |
- |
10000 |
|
20% Discount to BIS |
| Annex S-6(Grille covering material, cloth, and reticulated foam) |
- |
15000 |
|
20% Discount to BIS |
| Annex T-5(Steady force test, 250 N) |
- |
15000 |
|
20% Discount to BIS |
| Annex T-6(Enclosure impact test) |
- |
15000 |
|
20% Discount to BIS |
| Annex T-7(Drop test) |
- |
15000 |
|
20% Discount to BIS |
| Annex T-8(Stress relief test) |
- |
20000 |
|
20% Discount to BIS |
| Annex T-9(Glass impact test) |
- |
15000 |
|
20% Discount to BIS |
| Annex T-10(Glass fragmentation test) |
- |
15000 |
|
20% Discount to BIS |
| Annex T-11(Test for telescoping or rod antennas) |
- |
15000 |
|
20% Discount to BIS |
| Annex U("Mechanical strength of CRTs and protection against the effects
of implosion") |
- |
0 |
|
-- |
| Annex V-1(Accessible parts of equipment) |
- |
5000 |
|
20% Discount to BIS |
| Annex V-2(Accessible part criterion) |
- |
10000 |
|
20% Discount to BIS |
| Annex W(Comparison of terms introduced in this document) |
- |
5000 |
|
20% Discount to BIS |
| Annex X("Alternative method for determining clearances for insulation in
circuits connected to an AC mains not exceeding 420 V peak (300 V RMS)") |
- |
5000 |
|
20% Discount to BIS |
| Annex Y-1(General- Construction requirements for outdoor enclosures) |
- |
10000 |
|
20% Discount to BIS |
| Annex Y-2(Resistance to UV radiation) |
- |
0 |
|
-- |
| Annex Y-3(Resistance to corrosion) |
- |
0 |
|
-- |
| Annex Y-4(Gaskets) |
- |
0 |
|
-- |
| Annex Y-5(Protection of equipment within an outdoor enclosure) |
- |
25000 |
|
20% Discount to BIS |
| Annex Y-6(Mechanical strength of enclosures) |
- |
30000 |
|
20% Discount to BIS |
| Cl-4.1(General- materials, components) |
- |
0 |
|
- |
| Cl-4.2(Energy source classifications) |
- |
0 |
|
- |
| Cl-4.3(Protection against energy sources) |
- |
0 |
|
- |
| Cl-4.4(Safeguards) |
- |
0 |
|
- |
| Cl-4.5(Explosion) |
- |
0 |
|
- |
| Cl-4.6(Fixing of conductors and conductive parts) |
- |
0 |
|
- |
| Cl-4.7(Equipment for direct insertion into mains socket-outlets) |
- |
0 |
|
- |
| Cl-4.8(Equipment containing coin or button cell batteries) |
- |
0 |
|
- |
| Cl-4.9(Likelihood of fire or shock due to entry of conductive objects) |
- |
0 |
|
- |
| Cl-4.10(Components requirements) |
- |
0 |
|
- |
| Cl-5.1(General- Electrically-caused injury) |
- |
0 |
|
- |
| Cl-5.2(Classification and limits of electrical energy sources) |
- |
0 |
|
- |
| Cl-5.3(Protection against electrical energy sources) |
- |
0 |
|
- |
| Cl-5.4(Insulation materials and requirements) |
- |
0 |
|
- |
| Cl-5.5(Components as safeguards) |
- |
0 |
|
- |
| Cl-5.6(Protective conductor) |
- |
0 |
|
- |
| Cl-5.7(Prospective touch voltage, touch current and protective conductor current) |
- |
0 |
|
- |
| Cl-5.8(Backfeed safeguard in battery backed up supplies) |
- |
0 |
|
- |
| Cl-6.1(General- Electrically-caused fire) |
- |
0 |
|
- |
| Cl-6.2(Classification of power sources and potential ignition sources) |
- |
0 |
|
- |
| Cl-6.3(Safeguards against fire under normal operating conditions and abnormal operating conditions) |
- |
0 |
|
- |
| Cl-6.4(Safeguards against fire under single fault conditions) |
- |
0 |
|
- |
| Cl-6.5(Internal and external wiring) |
- |
0 |
|
- |
| Cl-7.1(General- Injury caused by hazardous substances) |
- |
0 |
|
- |
| Cl-7.2(Reduction of exposure to hazardous substances) |
- |
0 |
|
- |
| Cl-7.3(Ozone exposure) |
- |
0 |
|
- |
| Cl-7.4(Use of personal safeguards or personal protective equipment (PPE) |
- |
0 |
|
- |
| Cl-7.5(Use of instructional safeguards and instructions) |
- |
0 |
|
- |
| Cl-8.1(General- Mechanically-caused injury) |
- |
0 |
|
- |
| Cl-8.2(Mechanical energy source classifications) |
- |
0 |
|
- |
| Cl-8.3(Safeguards against mechanical energy sources) |
- |
0 |
|
- |
| Cl-8.4(Safeguards against parts with sharp edges and corners) |
- |
0 |
|
- |
| Cl-8.5(Safeguards against moving parts) |
- |
0 |
|
- |
| Cl-8.6(Stability of equipment) |
- |
0 |
|
- |
| Cl-8.7(Equipment mounted to a wall, ceiling or other structure) |
- |
0 |
|
- |
| Cl-8.8(Handle strength) |
- |
0 |
|
- |
| Cl-8.9(Wheels or casters attachment requirements) |
- |
0 |
|
- |
| Cl-8.10(Carts, stands, and similar carriers) |
- |
0 |
|
- |
| Cl-8.11(Mounting means for slide-rail mounted equipment (SRME)) |
- |
0 |
|
- |
| Cl-9.1(General-Thermal burn injury) |
- |
0 |
|
- |
| Cl-9.2(Thermal energy source classifications) |
- |
0 |
|
- |
| Cl-9.3(Touch temperature limits) |
- |
0 |
|
- |
| Cl-9.4(Safeguards against thermal energy sources) |
- |
0 |
|
- |
| Cl-9.5(Requirements for safeguards) |
- |
0 |
|
- |
| Cl-9.6(Requirements for wireless power transmitters) |
- |
0 |
|
- |
| Cl-10.1(General-Radiation) |
- |
0 |
|
- |
| Cl-10.2(Radiation energy source classifications) |
- |
0 |
|
- |
| Cl-10.3(Safeguards against laser radiation) |
- |
0 |
|
- |
| Cl-10.4("Safeguards against optical radiation from lamps and lamp systems
(including LED types)") |
- |
0 |
|
- |
| Cl-10.5(Safeguards against X-radiation) |
- |
0 |
|
- |
| Cl-10.6(Safeguards against acoustic energy sources) |
- |
0 |
|
- |
| Annex A(Examples of equipment within the scope of this document) |
- |
0 |
|
- |
| Annex B(General- Normal operating condition tests, abnormal operating condition tests and single fault condition tests) |
- |
0 |
|
- |
| Annex B-2(Normal operating conditions) |
- |
0 |
|
- |
| Annex B-3(Simulated abnormal operating conditions) |
- |
0 |
|
- |
| Annex B-4(Simulated single fault conditions) |
- |
0 |
|
- |
| Annex C-1(Protection of materials in equipment from UV radiation) |
- |
0 |
|
- |
| Annex C-2(UV light conditioning test) |
- |
0 |
|
- |
| Annex D-1(Impulse test generators) |
- |
0 |
|
- |
| Annex D-2(Antenna interface test generator) |
- |
0 |
|
- |
| Annex D-3(Electronic pulse generator) |
- |
0 |
|
- |
| Annex E-1(Electrical energy source classification for audio signals) |
- |
0 |
|
- |
| Annex E-2(Audio signals used during test) |
- |
0 |
|
- |
| Annex E-3(Operating conditions of equipment containing an audio amplifier) |
- |
0 |
|
- |
| Annex F-1(General-Equipment markings, instructions, and instructional safeguards) |
- |
0 |
|
- |
| Annex F-2(Letter symbols and graphical symbols) |
- |
0 |
|
- |
| Annex F-3(Equipment markings) |
- |
0 |
|
- |
| Annex F-4(Instructions) |
- |
0 |
|
- |
| Annex F-5(Instructional safeguards) |
- |
0 |
|
- |
| Annex G-1(Switches) |
- |
0 |
|
- |
| Annex G-2(Relays) |
- |
0 |
|
- |
| Annex G-3(Protective devices) |
- |
0 |
|
- |
| Annex G-4(Connectors) |
- |
0 |
|
- |
| Annex G-5(Wound components) |
- |
0 |
|
- |
| Annex G-6(Wire insulation) |
- |
0 |
|
- |
| Annex G-7(Mains power supply cords and interconnection cables) |
- |
0 |
|
- |
| Annex G-8(Varistors) |
- |
0 |
|
- |
| Annex G-9(Integrated circuit (IC) current limiters) |
- |
0 |
|
- |
| Annex G-10(Resistors) |
- |
0 |
|
- |
| Annex G-11(Capacitors and RC units) |
- |
0 |
|
- |
| Annex G-12(Optocouplers) |
- |
0 |
|
- |
| Annex G-14(Coatings on component terminals) |
- |
0 |
|
- |
| Annex G-15(Pressurized liquid filled components or LFC assemblies) |
- |
0 |
|
- |
| Annex G-16(IC that includes a capacitor discharge function (ICX)) |
- |
0 |
|
- |
| Annex H-1(General- Criteria for telephone ringing signals) |
- |
0 |
|
- |
| Annex H-2(Method A) |
- |
0 |
|
- |
| Annex H-3(Method B) |
- |
0 |
|
- |
| Annex I(Overvoltage categories (see IEC 60364-4-44)) |
- |
0 |
|
- |
| Annex J-1(General-Insulated winding wires for use without interleaved insulation) |
- |
0 |
|
- |
| Annex J-2(Type tests) |
- |
0 |
|
- |
| Annex J-3(Testing during manufacturing) |
- |
0 |
|
- |
| Annex K-1(General- Safety interlocks) |
- |
0 |
|
- |
| Annex K-2(Components of the safety interlock safeguard mechanism) |
- |
0 |
|
- |
| Annex K-3(Inadvertent change of operating mode) |
- |
0 |
|
- |
| Annex K-4(Interlock safeguard override) |
- |
0 |
|
- |
| Annex K-5(Fail-safe) |
- |
0 |
|
- |
| Annex K-6(Mechanically operated safety interlocks) |
- |
0 |
|
- |
| Annex K-7(Interlock circuit isolation) |
- |
0 |
|
- |
| Annex G-13(Printed boards) |
- |
0 |
|
- |
| Annex L-1(General requirements) |
- |
0 |
|
- |
| Annex L-2(Permanently connected equipment) |
- |
0 |
|
- |
| Annex L-3() |
- |
0 |
|
- |
| Annex L-4(Single-phase equipment) |
- |
0 |
|
- |
| Annex L-5(Three-phase equipment) |
- |
0 |
|
- |
| Annex L-6(Switches as disconnect devices) |
- |
0 |
|
- |
| Annex L-7(Plugs as disconnect devices) |
- |
0 |
|
- |
| Annex L-8(Multiple power sources) |
- |
0 |
|
- |
| Annex L-9(Compliance criteria) |
- |
0 |
|
- |
| Annex M-1(General requirements) |
- |
0 |
|
- |
| Annex M-2(Safety of batteries and their cells) |
- |
0 |
|
- |
| Annex M-3(Protection circuits for batteries provided within the equipment) |
- |
0 |
|
- |
| Annex M-4(Additional safeguards for equipment containing a secondary lithium battery) |
- |
0 |
|
- |
| Annex M-5(Risk of burn due to short-circuit during carrying) |
- |
0 |
|
- |
| Annex M-6(Safeguards against short-circuits) |
- |
0 |
|
- |
| Annex M-7(Risk of explosion from lead acid and NiCd batteries) |
- |
0 |
|
- |
| Annex M-8("Protection against internal ignition from external spark sources of
rechargeable batteries with aqueous electrolyte") |
- |
0 |
|
- |
| Annex M-9(Preventing electrolyte spillage) |
- |
0 |
|
- |
| Annex M-10(Instructions to prevent reasonably foreseeable misuse) |
- |
0 |
|
- |
| Annex N(Electrochemical potentials (V)) |
- |
0 |
|
- |
| Annex O(Measurement of creepage distances and clearances) |
- |
0 |
|
- |
| Annex P-1(General-Safeguards against conductive objects) |
- |
0 |
|
- |
| Annex P-2(Safeguards against entry or consequences of entry of a foreign object) |
- |
0 |
|
- |
| Annex P-3(Safeguards against spillage of internal liquids) |
- |
0 |
|
- |
| Annex P-4(Metallized coatings and adhesives securing parts) |
- |
0 |
|
- |
| Annex Q-1(Limited power source) |
- |
0 |
|
- |
| Annex Q-2(Test for external circuits – paired conductor cable) |
- |
0 |
|
- |
| Annex R(Limited short-circuit test) |
- |
0 |
|
- |
| Annex S-1(Flammability test for fire enclosure and fire barrier materials of equipment where the steady state power does not exceed 4 000 W) |
- |
0 |
|
- |
| Annex S-2(Flammability test for fire enclosure and fire barrier integrity) |
- |
0 |
|
- |
| Annex S-3(Flammability tests for the bottom of a fire enclosure) |
- |
0 |
|
- |
| Annex S-4(Flammability classification of materials) |
- |
0 |
|
- |
| Annex S-5(Flammability test for fire enclosure materials of equipment with a steady state power exceeding 4 000 W) |
- |
0 |
|
- |
| Annex T-1(General-Mechanical strength tests) |
- |
0 |
|
- |
| Annex T-2(Steady force test, 10 N) |
- |
0 |
|
- |
| Annex T-3(Steady force test, 30 N) |
- |
0 |
|
- |
| Annex T-4(Steady force test, 100 N) |
- |
0 |
|
- |
| Annex S-6(Grille covering material, cloth, and reticulated foam) |
- |
0 |
|
- |
| Annex T-5(Steady force test, 250 N) |
- |
0 |
|
- |
| Annex T-6(Enclosure impact test) |
- |
0 |
|
- |
| Annex T-7(Drop test) |
- |
0 |
|
- |
| Annex T-8(Stress relief test) |
- |
0 |
|
- |
| Annex T-9(Glass impact test) |
- |
0 |
|
- |
| Annex T-10(Glass fragmentation test) |
- |
0 |
|
- |
| Annex T-11(Test for telescoping or rod antennas) |
- |
0 |
|
- |
| Annex U("Mechanical strength of CRTs and protection against the effects
of implosion") |
- |
0 |
|
- |
| Annex V-1(Accessible parts of equipment) |
- |
0 |
|
- |
| Annex V-2(Accessible part criterion) |
- |
0 |
|
- |
| Annex W(Comparison of terms introduced in this document) |
- |
0 |
|
- |
| Annex X("Alternative method for determining clearances for insulation in
circuits connected to an AC mains not exceeding 420 V peak (300 V RMS)") |
- |
0 |
|
- |
| Annex Y-1(General- Construction requirements for outdoor enclosures) |
- |
0 |
|
- |
| Annex Y-2(Resistance to UV radiation) |
- |
0 |
|
- |
| Annex Y-3(Resistance to corrosion) |
- |
0 |
|
- |
| Annex Y-4(Gaskets) |
- |
0 |
|
- |
| Annex Y-5(Protection of equipment within an outdoor enclosure) |
- |
0 |
|
- |
| Annex Y-6(Mechanical strength of enclosures) |
- |
0 |
|
- |
|
11 Sep, 2027 |
- included w.e.f 11-12-2025
34 Exclusion. |
| 2 |
IS 302 : Part 2 : Sec 15 (2009) |
Safety of household and similar electrical appliances: Part 2 particular requirements: Sec 15 appliances for heating liquids (First Revision) |
- |
295000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6.0(Classification) |
- |
10000 |
|
20% Discount to BIS |
| 7(Marking and instructions) |
- |
10000 |
|
20% Discount to BIS |
| 8(Protection against live parts) |
- |
15000 |
|
20% Discount to BIS |
| 9(STARTING OF MOTOR-OPERATED APPLIANCES) |
- |
0 |
|
-- |
| 10(POWER INPUT AND CURRENT) |
- |
15000 |
|
20% Discount to BIS |
| 11(HEATING) |
- |
20000 |
|
20% Discount to BIS |
| 13(LEAKAGE CURRENT AND ELECTRIC STRENGTH AT OPERATING TEMPERATURE) |
- |
15000 |
|
20% Discount to BIS |
| 14(TRANSIENT OVERVOLTAGES) |
- |
10000 |
|
20% Discount to BIS |
| 15(MOISTURE RESISTANCE) |
- |
30000 |
|
20% Discount to BIS |
| 16(LEAKAGE CURRENT AND ELECTRIC STRENGTH) |
- |
15000 |
|
20% Discount to BIS |
| 17(OVERLOAD PROTECTION OF TRANSFORMERS AND ASSOCIATED CIRCUITS) |
- |
10000 |
|
20% Discount to BIS |
| 18(ENDURANCE) |
- |
0 |
|
-- |
| 19(ABNORMAL OPERATION) |
- |
20000 |
|
20% Discount to BIS |
| 20(STABILITY AND MECHANICAL HAZARDS) |
- |
15000 |
|
20% Discount to BIS |
| 21(MECHANICAL STRENGTH) |
- |
15000 |
|
20% Discount to BIS |
| 22(CONSTRUCTION) |
- |
20000 |
|
20% Discount to BIS |
| 23(INTERNAL WIRING) |
- |
10000 |
|
20% Discount to BIS |
| 24(COMPONENTS) |
- |
10000 |
|
20% Discount to BIS |
| 25(SUPPLY CONNECTION AND EXTERNAL FLEXIBLE CORDS) |
- |
15000 |
|
20% Discount to BIS |
| 26(TERMINALS FOR EXTERNAL CONDUCTORS) |
- |
10000 |
|
20% Discount to BIS |
| 27(PROVISION FOR EARTHING) |
- |
15000 |
|
20% Discount to BIS |
| 28(SCREWS AND CONNECTIONS) |
- |
10000 |
|
20% Discount to BIS |
| 29(CLEARANCES, CREEPAGE DISTANCES AND SOLID INSULATION) |
- |
15000 |
|
20% Discount to BIS |
| 30(RESISTANCE TO HEAT AND FIRE) |
- |
20000 |
|
20% Discount to BIS |
| 31(RESISTANCE TO RUSTING) |
- |
1000 |
|
20% Discount to BIS |
| 32(RADIATION, TOXICITY AND SIMILAR HAZARDS) |
- |
500 |
|
20% Discount to BIS |
| 22.16(Automatic cord reel) |
- |
0 |
|
-- |
| 22.32(Oxygen bomb for rubber material) |
- |
0 |
|
-- |
| 22.47(Water pressure inlet) |
- |
5000 |
|
20% Discount to BIS |
| 22.106(Interlocks) |
- |
10000 |
|
20% Discount to BIS |
| 22.3(Flexing test) |
- |
0 |
|
-- |
| 24(Components) |
- |
10000 |
|
20% Discount to BIS |
| 19.11.4.1(Electrostatic discharges) |
- |
15000 |
|
20% Discount to BIS |
| 19.11.4.2(Radiated fields) |
- |
40000 |
|
20% Discount to BIS |
| 19.11.4.3(Fast transient bursts) |
- |
15000 |
|
20% Discount to BIS |
| 19.11.4.4(Surge immunity test) |
- |
15000 |
|
20% Discount to BIS |
| 19.11.4.6(Class 3 Voltage dips and interruptions) |
- |
15000 |
|
20% Discount to BIS |
| 19.11.4.7(Harmonics) |
- |
15000 |
|
20% Discount to BIS |
| 4(General requirements) |
- |
1000 |
|
20% Discount to BIS |
| 5(General Conditions of tests) |
- |
1000 |
|
20% Discount to BIS |
| 19.11.4.5(Immunity to conducted discharges) |
- |
15000 |
|
20% Discount to BIS |
| 6(Classification- IS 302-1) |
- |
1000 |
|
20% Discount to BIS |
| 6(Classification- IS 302-1) |
- |
0 |
|
-- |
| 7.1(Marking- IS 302-1) |
- |
1000 |
|
20% Discount to BIS |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
-- |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
-- |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
-- |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
-- |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
-- |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
-- |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
-- |
| 7.1(Marking- IS 302-2-15) |
- |
0 |
|
-- |
| 7.3(Marking- IS 302-1) |
- |
1000 |
|
20% Discount to BIS |
| 7.4(Marking- IS 302-1) |
- |
1000 |
|
20% Discount to BIS |
| 7.5(Marking- IS 302-1) |
- |
1000 |
|
20% Discount to BIS |
| 7.6(Marking- IS 302-1) |
- |
1000 |
|
20% Discount to BIS |
| 7.7(Marking- IS 302-1) |
- |
1000 |
|
20% Discount to BIS |
| 7.8(Marking- IS 302-1) |
- |
1000 |
|
20% Discount to BIS |
| 6(Classification- IS 302-1) |
- |
0 |
|
-- |
| 6(Classification- IS 302-1) |
- |
0 |
|
-- |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
-- |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
-- |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
-- |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
-- |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
-- |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
-- |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
-- |
| Marking- IS 302-1(Marking- IS 302-1) |
- |
10000 |
|
20% Discount to BIS |
| 7.1(Marking- IS 302-2-15) |
- |
0 |
|
-- |
| 7.3(Marking- IS 302-1) |
- |
0 |
|
-- |
| 7.4(Marking- IS 302-1) |
- |
0 |
|
-- |
| 7.5(Marking- IS 302-1) |
- |
0 |
|
-- |
| 7.6(Marking- IS 302-1) |
- |
0 |
|
-- |
| 7.7(Marking- IS 302-1) |
- |
1000 |
|
20% Discount to BIS |
| 7.8(Marking- IS 302-1) |
- |
1000 |
|
20% Discount to BIS |
| 7.9(Marking- IS 302-1) |
- |
1000 |
|
20% Discount to BIS |
| 7.1O(Marking- IS 302-1) |
- |
1000 |
|
20% Discount to BIS |
| 7.11(Marking- IS 302-1) |
- |
1000 |
|
20% Discount to BIS |
| 7.12(Marking- IS 302-2-15) |
- |
1000 |
|
20% Discount to BIS |
| 7.12(Marking- IS 302-1) |
- |
1000 |
|
20% Discount to BIS |
| 7.12.1(Marking- IS 302-1) |
- |
1000 |
|
20% Discount to BIS |
| 7.12.3(Marking- IS 302-1) |
- |
1000 |
|
20% Discount to BIS |
| 7.12.5(Marking- IS 302-1) |
- |
1000 |
|
20% Discount to BIS |
| 7.12.6(Marking- IS 302-1) |
- |
1000 |
|
20% Discount to BIS |
| 7.13(Marking- IS 302-1) |
- |
1000 |
|
20% Discount to BIS |
| 7.14(Marking- IS 302-1) |
- |
10000 |
|
20% Discount to BIS |
| 7.15(Marking- IS 302-1) |
- |
1000 |
|
20% Discount to BIS |
| 7.101(Marking- IS 302-2-15) |
- |
1000 |
|
20% Discount to BIS |
| 8(Protection Against Electric Shock, IS 302-1) |
- |
0 |
|
-- |
| 10(Power Input and Current, IS 302-1) |
- |
0 |
|
-- |
| 11(Heating, IS 302-1) |
- |
0 |
|
-- |
| 11(Heating, IS 302-1) |
- |
0 |
|
-- |
| 11(Heating, IS 302-1) |
- |
0 |
|
-- |
| 11(Heating, IS 302-1) |
- |
0 |
|
-- |
| 13(Electrical Insulation and Leakage Current at Operating Temperature: Leakage current, IS 302-1) |
- |
0 |
|
-- |
| 13(Electrical Insulation and Leakage Current at Operating Temperature: High Voltage, IS 302-1) |
- |
0 |
|
-- |
| 15.1(Moisture Resistance, IS 302-1) |
- |
10000 |
|
20% Discount to BIS |
| 15.2(Spillage test as 15.2, IS 3.02-1 & 302-2-15) |
- |
10000 |
|
20% Discount to BIS |
| 16(Leakage current as per Cl 16, IS 302-1) |
- |
0 |
|
-- |
| 16(electric strength as per Cl 16, IS 302-1) |
- |
0 |
|
-- |
| 17(Overload protection of Transformers and Associated Circuits, IS 302-1) |
- |
0 |
|
-- |
| 19.13(Abnormal Operation as per Cl 19, IS 302-2-15) |
- |
15000 |
|
20% Discount to BIS |
| 19.13(Abnormal Operation as per Cl 19, IS 302-1) |
- |
0 |
|
-- |
| 19.13(Abnormal Operation as per Cl 19, IS 302-1) |
- |
0 |
|
-- |
| 19.13(Abnormal Operation as per Cl 19, IS 302-1) |
- |
0 |
|
-- |
| 20.1(Stability & Mechanical Hazards, IS 302-1) |
- |
10000 |
|
20% Discount to BIS |
| 21.1(Mechanical Strength, IS 302-1) |
- |
0 |
|
-- |
| 21.2(Mechanical Strength, IS 302-1) |
- |
10000 |
|
20% Discount to BIS |
| 22.1(Construction, IS 302-1) |
- |
10000 |
|
20% Discount to BIS |
| 22.7(Construction as per Cl 22.7, IS 3.02-2-15) |
- |
10000 |
|
20% Discount to BIS |
| 22.107(Construction as per Cl 22.7, IS 3.02-2-15) |
- |
10000 |
|
20% Discount to BIS |
| 22.108(Construction as per Cl 22.8, IS 3.02-2-15) |
- |
10000 |
|
20% Discount to BIS |
| 23.1(Internal Wiring, IS 302-1) |
- |
10000 |
|
20% Discount to BIS |
| 23.2(Internal Wiring, IS 302-1) |
- |
10000 |
|
20% Discount to BIS |
| 23.4(Internal Wiring, IS 302-1) |
- |
10000 |
|
20% Discount to BIS |
| 23.5(Internal Wiring, IS 302-1) |
- |
10000 |
|
20% Discount to BIS |
| 23.6(Internal Wiring, IS 302-1) |
- |
10000 |
|
20% Discount to BIS |
| 23.7(Internal Wiring, IS 302-1) |
- |
10000 |
|
20% Discount to BIS |
| 23.8(Internal Wiring, IS 302-1) |
- |
10000 |
|
20% Discount to BIS |
| 23.9(Internal Wiring, IS 302-1) |
- |
10000 |
|
20% Discount to BIS |
| 23.1O(Internal Wiring, IS 302-1) |
- |
10000 |
|
20% Discount to BIS |
| 25.1(Supply Connection and External Flexible Cords, IS 302-1) |
- |
10000 |
|
20% Discount to BIS |
| 25.2(Supply Connection and External Flexible Cords, IS 302-1) |
- |
10000 |
|
20% Discount to BIS |
| 25.5(Supply Connection and External Flexible Cords, IS 302-1) |
- |
10000 |
|
20% Discount to BIS |
| 25.6(Supply Connection and External Flexible Cords, IS 302-1) |
- |
10000 |
|
20% Discount to BIS |
| 25.8(Supply Connection and External Flexible Cords, IS 302-1) |
- |
10000 |
|
20% Discount to BIS |
| 25.9(Supply Connection and External Flexible Cords, IS 302-1) |
- |
10000 |
|
20% Discount to BIS |
| 25.1(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
-- |
| 25.11(Supply Connection and External Flexible Cords, IS 302-1) |
- |
10000 |
|
20% Discount to BIS |
| 25.12(Supply Connection and External Flexible Cords, IS 302-1) |
- |
10000 |
|
20% Discount to BIS |
| 25.13(Supply Connection and External Flexible Cords, IS 302-1) |
- |
10000 |
|
20% Discount to BIS |
| 25.14(Supply Connection and External Flexible Cords, IS 302-1) |
- |
10000 |
|
20% Discount to BIS |
| 25.14(Supply Connection and External Flexible Cords, IS 302-1) |
- |
10000 |
|
20% Discount to BIS |
| 25.15(Supply Connection and External Flexible Cords, IS 302-1) |
- |
10000 |
|
20% Discount to BIS |
| 25.16(Supply Connection and External Flexible Cords, IS 302-1) |
- |
10000 |
|
20% Discount to BIS |
| 25.17(Supply Connection and External Flexible Cords, IS 302-1) |
- |
10000 |
|
20% Discount to BIS |
| 25.18(Supply Connection and External Flexible Cords, IS 302-1) |
- |
10000 |
|
20% Discount to BIS |
| 25.19(Supply Connection and External Flexible Cords, IS 302-1) |
- |
10000 |
|
20% Discount to BIS |
| 25.2(Supply Connection and External Flexible Cords, IS 302-1) |
- |
10000 |
|
20% Discount to BIS |
| 25.21(Supply Connection and External Flexible Cords, IS 302-1) |
- |
10000 |
|
20% Discount to BIS |
| 25.22(Supply Connection and External Flexible Cords, IS 302-1) |
- |
10000 |
|
20% Discount to BIS |
| 26(Terminals for External Conductors, IS 302-1) |
- |
15000 |
|
20% Discount to BIS |
| 27.1(Provision for Earthing, IS 302-1) |
- |
10000 |
|
20% Discount to BIS |
| 27.2(Provision for Earthing, IS 302-1) |
- |
10000 |
|
20% Discount to BIS |
| 27.3(Provision for Earthing, IS 302-1) |
- |
10000 |
|
20% Discount to BIS |
| 27.4(Provision for Earthing, IS 302-1) |
- |
10000 |
|
20% Discount to BIS |
| 27.5(Provision for Earthing, IS 302-1) |
- |
15000 |
|
20% Discount to BIS |
| 28(Screws & Connections, IS 302-1) |
- |
15000 |
|
20% Discount to BIS |
| 29.1(Clearances, Creepage distances and Solid Insulation, IS 302-1) |
- |
10000 |
|
20% Discount to BIS |
| 29.2(Clearances, Creepage distances and Solid Insulation, IS 302-1) |
- |
15000 |
|
20% Discount to BIS |
| 30.1(Resistance to Heat and Fire, IS 302-1) |
- |
10000 |
|
20% Discount to BIS |
| 30.2(Resistance to Heat and Fire, IS 302-1) |
- |
20000 |
|
20% Discount to BIS |
| 31(Resistance of Rusting, IS 302-1) |
- |
10000 |
|
20% Discount to BIS |
| 6.0(Classification) |
- |
5000 |
|
20% Discount to BIS |
| 7(Marking and instructions) |
- |
10000 |
|
20% Discount to BIS |
| 8(Protection against live parts) |
- |
10000 |
|
20% Discount to BIS |
| 9(STARTING OF MOTOR-OPERATED APPLIANCES) |
- |
0 |
|
-- |
| 10(POWER INPUT AND CURRENT) |
- |
15000 |
|
20% Discount to BIS |
| 11(HEATING) |
- |
25000 |
|
20% Discount to BIS |
| 13(LEAKAGE CURRENT AND ELECTRIC STRENGTH AT OPERATING TEMPERATURE) |
- |
15000 |
|
20% Discount to BIS |
| 14(TRANSIENT OVERVOLTAGES) |
- |
10000 |
|
20% Discount to BIS |
| 15(MOISTURE RESISTANCE) |
- |
25000 |
|
20% Discount to BIS |
| 16(LEAKAGE CURRENT AND ELECTRIC STRENGTH) |
- |
15000 |
|
20% Discount to BIS |
| 17(OVERLOAD PROTECTION OF TRANSFORMERS AND ASSOCIATED CIRCUITS) |
- |
15000 |
|
20% Discount to BIS |
| 18(ENDURANCE) |
- |
0 |
|
-- |
| 19(ABNORMAL OPERATION) |
- |
20000 |
|
20% Discount to BIS |
| 20(STABILITY AND MECHANICAL HAZARDS) |
- |
10000 |
|
20% Discount to BIS |
| 21(MECHANICAL STRENGTH) |
- |
10000 |
|
20% Discount to BIS |
| 22(CONSTRUCTION) |
- |
15000 |
|
20% Discount to BIS |
| 23(INTERNAL WIRING) |
- |
10000 |
|
20% Discount to BIS |
| 24(COMPONENTS) |
- |
15000 |
|
20% Discount to BIS |
| 25(SUPPLY CONNECTION AND EXTERNAL FLEXIBLE CORDS) |
- |
15000 |
|
20% Discount to BIS |
| 26(TERMINALS FOR EXTERNAL CONDUCTORS) |
- |
10000 |
|
20% Discount to BIS |
| 27(PROVISION FOR EARTHING) |
- |
15000 |
|
20% Discount to BIS |
| 28(SCREWS AND CONNECTIONS) |
- |
10000 |
|
20% Discount to BIS |
| 29(CLEARANCES, CREEPAGE DISTANCES AND SOLID INSULATION) |
- |
10000 |
|
20% Discount to BIS |
| 30(RESISTANCE TO HEAT AND FIRE) |
- |
10000 |
|
20% Discount to BIS |
| 31(RESISTANCE TO RUSTING) |
- |
10000 |
|
20% Discount to BIS |
| 32(RADIATION, TOXICITY AND SIMILAR HAZARDS) |
- |
1000 |
|
20% Discount to BIS |
| 22.16(Automatic cord reel) |
- |
0 |
|
- |
| 22.32(Oxygen bomb for rubber material) |
- |
0 |
|
- |
| 22.47(Water pressure inlet) |
- |
5000 |
|
20% Discount to BIS |
| 22.106(Interlocks) |
- |
5000 |
|
20% Discount to BIS |
| 22.3(Flexing test) |
- |
0 |
|
-- |
| 24(Components) |
- |
15000 |
|
20% Discount to BIS |
| 19.11.4.1(Electrostatic discharges) |
- |
15000 |
|
20% Discount to BIS |
| 19.11.4.2(Radiated fields) |
- |
40000 |
|
20% Discount to BIS |
| 19.11.4.3(Fast transient bursts) |
- |
15000 |
|
20% Discount to BIS |
| 19.11.4.4(Surge immunity test) |
- |
15000 |
|
20% Discount to BIS |
| 19.11.4.6(Class 3 Voltage dips and interruptions) |
- |
15000 |
|
20% Discount to BIS |
| 19.11.4.7(Harmonics) |
- |
15000 |
|
20% Discount to BIS |
| 4(General requirements) |
- |
1000 |
|
20% Discount to BIS |
| 5(General Conditions of tests) |
- |
1000 |
|
20% Discount to BIS |
| 19.11.4.5(Immunity to conducted discharges) |
- |
15000 |
|
20% Discount to BIS |
| 6(Classification- IS 302-1) |
- |
10000 |
|
20% Discount to BIS |
| 6(Classification- IS 302-1) |
- |
9 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
1000 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.1(Marking- IS 302-2-15) |
- |
0 |
|
- |
| 7.3(Marking- IS 302-1) |
- |
1000 |
|
20% Discount to BIS |
| 7.4(Marking- IS 302-1) |
- |
1000 |
|
20% Discount to BIS |
| 7.5(Marking- IS 302-1) |
- |
1000 |
|
20% Discount to BIS |
| 7.6(Marking- IS 302-1) |
- |
1000 |
|
20% Discount to BIS |
| 7.7(Marking- IS 302-1) |
- |
1000 |
|
20% Discount to BIS |
| 7.8(Marking- IS 302-1) |
- |
1000 |
|
20% Discount to BIS |
| 6(Classification- IS 302-1) |
- |
10000 |
|
20% Discount to BIS |
| 6(Classification- IS 302-1) |
- |
0 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
- |
| Marking- IS 302-1(Marking- IS 302-1) |
- |
10000 |
|
20% Discount to BIS |
| 7.1(Marking- IS 302-2-15) |
- |
0 |
|
- |
| 7.3(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.4(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.5(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.6(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.7(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.8(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.9(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.1O(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.11(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.12(Marking- IS 302-2-15) |
- |
0 |
|
- |
| 7.12(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.12.1(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.12.3(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.12.5(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.12.6(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.13(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.14(Marking- IS 302-1) |
- |
10000 |
|
20% Discount to BIS |
| 7.15(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.101(Marking- IS 302-2-15) |
- |
1000 |
|
20% Discount to BIS |
| 8(Protection Against Electric Shock, IS 302-1) |
- |
10000 |
|
20% Discount to BIS |
| 10(Power Input and Current, IS 302-1) |
- |
15000 |
|
- |
| 11(Heating, IS 302-1) |
- |
25000 |
|
- |
| 11(Heating, IS 302-1) |
- |
0 |
|
- |
| 11(Heating, IS 302-1) |
- |
0 |
|
- |
| 11(Heating, IS 302-1) |
- |
0 |
|
- |
| 13(Electrical Insulation and Leakage Current at Operating Temperature: Leakage current, IS 302-1) |
- |
15000 |
|
- |
| 13(Electrical Insulation and Leakage Current at Operating Temperature: High Voltage, IS 302-1) |
- |
15000 |
|
- |
| 15.1(Moisture Resistance, IS 302-1) |
- |
10000 |
|
- |
| 15.2(Spillage test as 15.2, IS 3.02-1 & 302-2-15) |
- |
10000 |
|
20% Discount to BIS |
| 16(Leakage current as per Cl 16, IS 302-1) |
- |
15000 |
|
20% Discount to BIS |
| 16(electric strength as per Cl 16, IS 302-1) |
- |
15000 |
|
20% Discount to BIS |
| 17(Overload protection of Transformers and Associated Circuits, IS 302-1) |
- |
15000 |
|
20% Discount to BIS |
| 19.13(Abnormal Operation as per Cl 19, IS 302-2-15) |
- |
15000 |
|
20% Discount to BIS |
| 19.13(Abnormal Operation as per Cl 19, IS 302-1) |
- |
15000 |
|
20% Discount to BIS |
| 19.13(Abnormal Operation as per Cl 19, IS 302-1) |
- |
15000 |
|
20% Discount to BIS |
| 19.13(Abnormal Operation as per Cl 19, IS 302-1) |
- |
0 |
|
- |
| 20.1(Stability & Mechanical Hazards, IS 302-1) |
- |
10000 |
|
20% Discount to BIS |
| 21.1(Mechanical Strength, IS 302-1) |
- |
10000 |
|
20% Discount to BIS |
| 21.2(Mechanical Strength, IS 302-1) |
- |
10000 |
|
20% Discount to BIS |
| 22.1(Construction, IS 302-1) |
- |
10000 |
|
20% Discount to BIS |
| 22.7(Construction as per Cl 22.7, IS 3.02-2-15) |
- |
10000 |
|
20% Discount to BIS |
| 22.107(Construction as per Cl 22.7, IS 3.02-2-15) |
- |
10000 |
|
20% Discount to BIS |
| 22.108(Construction as per Cl 22.8, IS 3.02-2-15) |
- |
10000 |
|
20% Discount to BIS |
| 23.1(Internal Wiring, IS 302-1) |
- |
10000 |
|
20% Discount to BIS |
| 23.2(Internal Wiring, IS 302-1) |
- |
10000 |
|
20% Discount to BIS |
| 23.4(Internal Wiring, IS 302-1) |
- |
10000 |
|
20% Discount to BIS |
| 23.5(Internal Wiring, IS 302-1) |
- |
5000 |
|
20% Discount to BIS |
| 23.6(Internal Wiring, IS 302-1) |
- |
5000 |
|
20% Discount to BIS |
| 23.7(Internal Wiring, IS 302-1) |
- |
5000 |
|
20% Discount to BIS |
| 23.8(Internal Wiring, IS 302-1) |
- |
1000 |
|
20% Discount to BIS |
| 23.9(Internal Wiring, IS 302-1) |
- |
1000 |
|
20% Discount to BIS |
| 23.1O(Internal Wiring, IS 302-1) |
- |
1000 |
|
20% Discount to BIS |
| 25.1(Supply Connection and External Flexible Cords, IS 302-1) |
- |
1000 |
|
20% Discount to BIS |
| 25.2(Supply Connection and External Flexible Cords, IS 302-1) |
- |
1000 |
|
20% Discount to BIS |
| 25.5(Supply Connection and External Flexible Cords, IS 302-1) |
- |
1000 |
|
20% Discount to BIS |
| 25.6(Supply Connection and External Flexible Cords, IS 302-1) |
- |
10000 |
|
20% Discount to BIS |
| 25.8(Supply Connection and External Flexible Cords, IS 302-1) |
- |
1000 |
|
20% Discount to BIS |
| 25.9(Supply Connection and External Flexible Cords, IS 302-1) |
- |
1000 |
|
20% Discount to BIS |
| 25.1(Supply Connection and External Flexible Cords, IS 302-1) |
- |
10000 |
|
20% Discount to BIS |
| 25.11(Supply Connection and External Flexible Cords, IS 302-1) |
- |
10000 |
|
20% Discount to BIS |
| 25.12(Supply Connection and External Flexible Cords, IS 302-1) |
- |
10000 |
|
20% Discount to BIS |
| 25.13(Supply Connection and External Flexible Cords, IS 302-1) |
- |
10000 |
|
20% Discount to BIS |
| 25.14(Supply Connection and External Flexible Cords, IS 302-1) |
- |
10000 |
|
20% Discount to BIS |
| 25.14(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.15(Supply Connection and External Flexible Cords, IS 302-1) |
- |
10000 |
|
20% Discount to BIS |
| 25.16(Supply Connection and External Flexible Cords, IS 302-1) |
- |
10000 |
|
20% Discount to BIS |
| 25.17(Supply Connection and External Flexible Cords, IS 302-1) |
- |
10000 |
|
20% Discount to BIS |
| 25.18(Supply Connection and External Flexible Cords, IS 302-1) |
- |
10000 |
|
20% Discount to BIS |
| 25.19(Supply Connection and External Flexible Cords, IS 302-1) |
- |
10000 |
|
20% Discount to BIS |
| 25.2(Supply Connection and External Flexible Cords, IS 302-1) |
- |
10000 |
|
20% Discount to BIS |
| 25.21(Supply Connection and External Flexible Cords, IS 302-1) |
- |
10000 |
|
20% Discount to BIS |
| 25.22(Supply Connection and External Flexible Cords, IS 302-1) |
- |
10000 |
|
20% Discount to BIS |
| 26(Terminals for External Conductors, IS 302-1) |
- |
15000 |
|
20% Discount to BIS |
| 27.1(Provision for Earthing, IS 302-1) |
- |
15000 |
|
20% Discount to BIS |
| 27.2(Provision for Earthing, IS 302-1) |
- |
1000 |
|
20% Discount to BIS |
| 27.3(Provision for Earthing, IS 302-1) |
- |
1000 |
|
20% Discount to BIS |
| 27.4(Provision for Earthing, IS 302-1) |
- |
10000 |
|
20% Discount to BIS |
| 27.5(Provision for Earthing, IS 302-1) |
- |
10000 |
|
20% Discount to BIS |
| 28(Screws & Connections, IS 302-1) |
- |
15000 |
|
20% Discount to BIS |
| 29.1(Clearances, Creepage distances and Solid Insulation, IS 302-1) |
- |
10000 |
|
20% Discount to BIS |
| 29.2(Clearances, Creepage distances and Solid Insulation, IS 302-1) |
- |
10000 |
|
20% Discount to BIS |
| 30.1(Resistance to Heat and Fire, IS 302-1) |
- |
10000 |
|
20% Discount to BIS |
| 30.2(Resistance to Heat and Fire, IS 302-1) |
- |
10000 |
|
20% Discount to BIS |
| 31(Resistance of Rusting, IS 302-1) |
- |
10000 |
|
20% Discount to BIS |
| Cl. 15.02(stands for cordless kettles) |
- |
5000 |
|
20% Discount to BIS |
| Cl.22.103(appliance coupler of cordless kettles) |
- |
10000 |
|
20% Discount to BIS |
| 6.0(Classification) |
- |
0 |
|
- |
| 7(Marking and instructions) |
- |
0 |
|
- |
| 8(Protection against live parts) |
- |
0 |
|
- |
| 9(STARTING OF MOTOR-OPERATED APPLIANCES) |
- |
0 |
|
- |
| 10(POWER INPUT AND CURRENT) |
- |
0 |
|
- |
| 11(HEATING) |
- |
0 |
|
- |
| 13(LEAKAGE CURRENT AND ELECTRIC STRENGTH AT OPERATING TEMPERATURE) |
- |
0 |
|
- |
| 14(TRANSIENT OVERVOLTAGES) |
- |
0 |
|
- |
| 15(MOISTURE RESISTANCE) |
- |
0 |
|
- |
| 16(LEAKAGE CURRENT AND ELECTRIC STRENGTH) |
- |
0 |
|
- |
| 17(OVERLOAD PROTECTION OF TRANSFORMERS AND ASSOCIATED CIRCUITS) |
- |
0 |
|
- |
| 18(ENDURANCE) |
- |
0 |
|
- |
| 19(ABNORMAL OPERATION) |
- |
0 |
|
- |
| 20(STABILITY AND MECHANICAL HAZARDS) |
- |
0 |
|
- |
| 21(MECHANICAL STRENGTH) |
- |
0 |
|
- |
| 22(CONSTRUCTION) |
- |
0 |
|
- |
| 23(INTERNAL WIRING) |
- |
0 |
|
- |
| 24(COMPONENTS) |
- |
0 |
|
- |
| 25(SUPPLY CONNECTION AND EXTERNAL FLEXIBLE CORDS) |
- |
0 |
|
- |
| 26(TERMINALS FOR EXTERNAL CONDUCTORS) |
- |
0 |
|
- |
| 27(PROVISION FOR EARTHING) |
- |
0 |
|
- |
| 28(SCREWS AND CONNECTIONS) |
- |
0 |
|
- |
| 29(CLEARANCES, CREEPAGE DISTANCES AND SOLID INSULATION) |
- |
0 |
|
- |
| 30(RESISTANCE TO HEAT AND FIRE) |
- |
0 |
|
- |
| 31(RESISTANCE TO RUSTING) |
- |
0 |
|
- |
| 32(RADIATION, TOXICITY AND SIMILAR HAZARDS) |
- |
0 |
|
- |
| 22.16(Automatic cord reel) |
- |
0 |
|
- |
| 22.32(Oxygen bomb for rubber material) |
- |
0 |
|
- |
| 22.47(Water pressure inlet) |
- |
0 |
|
- |
| 22.106(Interlocks) |
- |
0 |
|
- |
| 22.3(Flexing test) |
- |
0 |
|
- |
| 24(Components) |
- |
0 |
|
- |
| 19.11.4.1(Electrostatic discharges) |
- |
0 |
|
- |
| 19.11.4.2(Radiated fields) |
- |
0 |
|
- |
| 19.11.4.3(Fast transient bursts) |
- |
0 |
|
- |
| 19.11.4.4(Surge immunity test) |
- |
0 |
|
- |
| 19.11.4.6(Class 3 Voltage dips and interruptions) |
- |
0 |
|
- |
| 19.11.4.7(Harmonics) |
- |
0 |
|
- |
| 4(General requirements) |
- |
0 |
|
- |
| 5(General Conditions of tests) |
- |
0 |
|
- |
| 19.11.4.5(Immunity to conducted discharges) |
- |
0 |
|
- |
| 6(Classification- IS 302-1) |
- |
0 |
|
- |
| 6(Classification- IS 302-1) |
- |
0 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.1(Marking- IS 302-2-15) |
- |
0 |
|
- |
| 7.3(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.4(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.5(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.6(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.7(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.8(Marking- IS 302-1) |
- |
0 |
|
- |
| 6(Classification- IS 302-1) |
- |
0 |
|
- |
| 6(Classification- IS 302-1) |
- |
0 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
- |
| Marking- IS 302-1(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.1(Marking- IS 302-2-15) |
- |
0 |
|
- |
| 7.3(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.4(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.5(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.6(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.7(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.8(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.9(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.1O(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.11(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.12(Marking- IS 302-2-15) |
- |
0 |
|
- |
| 7.12(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.12.1(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.12.3(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.12.5(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.12.6(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.13(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.14(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.15(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.101(Marking- IS 302-2-15) |
- |
0 |
|
- |
| 8(Protection Against Electric Shock, IS 302-1) |
- |
0 |
|
- |
| 10(Power Input and Current, IS 302-1) |
- |
0 |
|
- |
| 11(Heating, IS 302-1) |
- |
0 |
|
- |
| 11(Heating, IS 302-1) |
- |
0 |
|
- |
| 11(Heating, IS 302-1) |
- |
0 |
|
- |
| 11(Heating, IS 302-1) |
- |
0 |
|
- |
| 13(Electrical Insulation and Leakage Current at Operating Temperature: Leakage current, IS 302-1) |
- |
0 |
|
- |
| 13(Electrical Insulation and Leakage Current at Operating Temperature: High Voltage, IS 302-1) |
- |
0 |
|
- |
| 15.1(Moisture Resistance, IS 302-1) |
- |
0 |
|
- |
| 15.2(Spillage test as 15.2, IS 3.02-1 & 302-2-15) |
- |
0 |
|
- |
| 16(Leakage current as per Cl 16, IS 302-1) |
- |
0 |
|
- |
| 16(electric strength as per Cl 16, IS 302-1) |
- |
0 |
|
- |
| 17(Overload protection of Transformers and Associated Circuits, IS 302-1) |
- |
0 |
|
- |
| 19.13(Abnormal Operation as per Cl 19, IS 302-2-15) |
- |
0 |
|
- |
| 19.13(Abnormal Operation as per Cl 19, IS 302-1) |
- |
0 |
|
- |
| 19.13(Abnormal Operation as per Cl 19, IS 302-1) |
- |
0 |
|
- |
| 19.13(Abnormal Operation as per Cl 19, IS 302-1) |
- |
0 |
|
- |
| 20.1(Stability & Mechanical Hazards, IS 302-1) |
- |
0 |
|
- |
| 21.1(Mechanical Strength, IS 302-1) |
- |
0 |
|
- |
| 21.2(Mechanical Strength, IS 302-1) |
- |
0 |
|
- |
| 22.1(Construction, IS 302-1) |
- |
0 |
|
- |
| 22.7(Construction as per Cl 22.7, IS 3.02-2-15) |
- |
0 |
|
- |
| 22.107(Construction as per Cl 22.7, IS 3.02-2-15) |
- |
0 |
|
- |
| 22.108(Construction as per Cl 22.8, IS 3.02-2-15) |
- |
0 |
|
- |
| 23.1(Internal Wiring, IS 302-1) |
- |
0 |
|
- |
| 23.2(Internal Wiring, IS 302-1) |
- |
0 |
|
- |
| 23.4(Internal Wiring, IS 302-1) |
- |
0 |
|
- |
| 23.5(Internal Wiring, IS 302-1) |
- |
0 |
|
- |
| 23.6(Internal Wiring, IS 302-1) |
- |
0 |
|
- |
| 23.7(Internal Wiring, IS 302-1) |
- |
0 |
|
- |
| 23.8(Internal Wiring, IS 302-1) |
- |
0 |
|
- |
| 23.9(Internal Wiring, IS 302-1) |
- |
0 |
|
- |
| 23.1O(Internal Wiring, IS 302-1) |
- |
0 |
|
- |
| 25.1(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.2(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.5(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.6(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.8(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.9(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.1(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.11(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.12(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.13(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.14(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.14(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.15(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.16(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.17(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.18(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.19(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.2(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.21(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.22(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 26(Terminals for External Conductors, IS 302-1) |
- |
0 |
|
- |
| 27.1(Provision for Earthing, IS 302-1) |
- |
0 |
|
- |
| 27.2(Provision for Earthing, IS 302-1) |
- |
0 |
|
- |
| 27.3(Provision for Earthing, IS 302-1) |
- |
0 |
|
- |
| 27.4(Provision for Earthing, IS 302-1) |
- |
0 |
|
- |
| 27.5(Provision for Earthing, IS 302-1) |
- |
0 |
|
- |
| 28(Screws & Connections, IS 302-1) |
- |
0 |
|
- |
| 29.1(Clearances, Creepage distances and Solid Insulation, IS 302-1) |
- |
0 |
|
- |
| 29.2(Clearances, Creepage distances and Solid Insulation, IS 302-1) |
- |
0 |
|
- |
| 30.1(Resistance to Heat and Fire, IS 302-1) |
- |
0 |
|
- |
| 30.2(Resistance to Heat and Fire, IS 302-1) |
- |
0 |
|
- |
| 31(Resistance of Rusting, IS 302-1) |
- |
0 |
|
- |
| Cl. 15.02(stands for cordless kettles) |
- |
0 |
|
- |
| Cl.22.103(appliance coupler of cordless kettles) |
- |
0 |
|
- |
| Cl-19.3(Abnormal operation test) |
- |
0 |
|
- |
| Cl-19.101("Abnormal operation test
") |
- |
0 |
|
- |
| Cl-19.102("Abnormal operation test
") |
- |
0 |
|
- |
| Cl-19.103("Abnormal operation test
") |
- |
0 |
|
- |
| Cl-22.103(Construction) |
- |
0 |
|
- |
| Cl-25.101(" Supply connection And external flexible ") |
- |
0 |
|
- |
|
11 Sep, 2027 |
- Included w.e.f 12.11.2025
Exclusion: Cl 8 (Protection against live parts), 22.16 (Automatic cord reel), 22.32 (Oxygen bomb for rubber material), Cl. 23.3 (Flexing test), Cl.22.48 (Appliances connected to the water mains) |
| 3 |
IS 302 : Part 2 : Sec 14 (2009) |
Safety of household and similar electrical appliances: Part 2 particular requirements: Sec 14 electric kitchen machines (First Revision) |
Except for ice-cream machines for use in refrigerators and freezers. |
300000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6(Classification- IS 302-1 ) |
- |
10000 |
|
20% Discount to BIS |
| 6(Classification- IS 302-1) |
- |
0 |
|
-- |
| 7.1(Marking- IS 302-1) |
- |
5000 |
|
20% Discount to BIS |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
-- |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
-- |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
-- |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
-- |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
-- |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
-- |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
-- |
| 7.3(Marking- IS 302-1) |
- |
1000 |
|
20% Discount to BIS |
| 7.4(Marking- IS 302-1) |
- |
1000 |
|
20% Discount to BIS |
| 7.6(Marking- IS 302-1) |
- |
1000 |
|
20% Discount to BIS |
| 7.7(Marking- IS 302-1) |
- |
1000 |
|
20% Discount to BIS |
| 7.8(Marking- IS 302-1) |
- |
1000 |
|
20% Discount to BIS |
| 7.11(Marking- IS 302-1) |
- |
1000 |
|
20% Discount to BIS |
| 7.12(Marking- IS 302-1) |
- |
1000 |
|
20% Discount to BIS |
| 7.13(Marking- IS 302-1) |
- |
1000 |
|
20% Discount to BIS |
| 7.14(Marking- IS 302-1) |
- |
5000 |
|
20% Discount to BIS |
| 7.15(Marking- IS 302-1) |
- |
1000 |
|
20% Discount to BIS |
| 7.101(Marking) |
- |
1000 |
|
20% Discount to BIS |
| 8( Protection Against Electric Shock, IS 302-1) |
- |
10000 |
|
20% Discount to BIS |
| 10(Power Input and Current, IS 302-1) |
- |
15000 |
|
20% Discount to BIS |
| 11(Heating, IS 302-1) |
- |
15000 |
|
20% Discount to BIS |
| 11(Heating, IS 302-1) |
- |
0 |
|
-- |
| 11(Heating, IS 302-1) |
- |
0 |
|
-- |
| 11(Heating, IS 302-1) |
- |
0 |
|
-- |
| 11(Heating, IS 302-1) |
- |
0 |
|
-- |
| 13(Electrical Insulation and Leakage Current at Operating Temperature: Leakage current, IS 302-1) |
- |
10000 |
|
20% Discount to BIS |
| 13(Electrical Insulation and Leakage Current at Operating Temperature: High Voltage, IS 302-1) |
- |
10000 |
|
20% Discount to BIS |
| 14(Transient Over Voltages, IS 302-1) |
- |
10000 |
|
20% Discount to BIS |
| 15.1(Moisture Resistance, IS 302-1) |
- |
1000 |
|
20% Discount to BIS |
| 15.2(Moisture Resistance, IS 302-1) |
- |
10000 |
|
20% Discount to BIS |
| 15(Moisture Resistance, IS 302-1) |
- |
30000 |
|
20% Discount to BIS |
| 16(Electrical Insulation and Leakage Current at Operating Temperature: Leakage current, IS 302-1) |
- |
10000 |
|
20% Discount to BIS |
| 16(Electrical Insulation and Leakage Current at Operating Temperature: High Voltage, IS 302-1) |
- |
10000 |
|
20% Discount to BIS |
| 17(Overload protection of Transformers and Associated Circuits, IS 302-1) |
- |
10000 |
|
20% Discount to BIS |
| 17(Overload protection of Transformers and Associated Circuits, IS 302-1) |
- |
0 |
|
-- |
| 19.7(Abnormal Operation, IS 302-1) |
- |
10000 |
|
20% Discount to BIS |
| 19.8(Abnormal Operation, IS 302-1) |
- |
5000 |
|
20% Discount to BIS |
| 19.9(Abnormal Operation, IS 302-1) |
- |
5000 |
|
20% Discount to BIS |
| 19.1(Abnormal Operation, IS 302-1) |
- |
1000 |
|
20% Discount to BIS |
| 19.101(Abnormal Operation) |
- |
2000 |
|
20% Discount to BIS |
| 19.102(Abnormal Operation) |
- |
2000 |
|
20% Discount to BIS |
| 20.1(Stability & Mechanical Hazards, IS 302-1) |
- |
5000 |
|
20% Discount to BIS |
| 20.2(Stability & Mechanical Hazards, IS 302-1) |
- |
5000 |
|
20% Discount to BIS |
| 20.101(Stability & Mechanical Hazards) |
- |
5000 |
|
20% Discount to BIS |
| 20.102(Stability & Mechanical Hazards) |
- |
5000 |
|
20% Discount to BIS |
| 20.103(Stability & Mechanical Hazards) |
- |
5000 |
|
20% Discount to BIS |
| 20.104(Stability & Mechanical Hazards) |
- |
5000 |
|
20% Discount to BIS |
| 20.105(Stability & Mechanical Hazards) |
- |
5000 |
|
20% Discount to BIS |
| 20.106(Stability & Mechanical Hazards) |
- |
5000 |
|
20% Discount to BIS |
| 20.107(Stability & Mechanical Hazards) |
- |
5000 |
|
20% Discount to BIS |
| 20.108(Stability & Mechanical Hazards) |
- |
5000 |
|
20% Discount to BIS |
| 20.109(Stability & Mechanical Hazards) |
- |
5000 |
|
20% Discount to BIS |
| 20.110(Stability & Mechanical Hazards) |
- |
5000 |
|
20% Discount to BIS |
| 20.111(Stability & Mechanical Hazards) |
- |
5000 |
|
20% Discount to BIS |
| 20.112(Stability & Mechanical Hazards) |
- |
5000 |
|
20% Discount to BIS |
| 20.113(Stability & Mechanical Hazards) |
- |
5000 |
|
20% Discount to BIS |
| 20.114(Stability & Mechanical Hazards) |
- |
5000 |
|
20% Discount to BIS |
| 20.115(Stability & Mechanical Hazards) |
- |
5000 |
|
20% Discount to BIS |
| 20.116(Stability & Mechanical Hazards) |
- |
5000 |
|
20% Discount to BIS |
| 21.1(Mechanical Strength, IS 302-1) |
- |
5000 |
|
20% Discount to BIS |
| 21.2(Mechanical Strength, IS 302-1) |
- |
5000 |
|
20% Discount to BIS |
| 22(Construction, IS 302-1) |
- |
5000 |
|
20% Discount to BIS |
| 22.101(Construction) |
- |
5000 |
|
20% Discount to BIS |
| 22.102(Construction) |
- |
5000 |
|
20% Discount to BIS |
| 23.1(Internal Wiring, IS 302-1) |
- |
1000 |
|
20% Discount to BIS |
| 23.2(Internal Wiring, IS 302-1) |
- |
1000 |
|
20% Discount to BIS |
| 23.3(Internal Wiring, IS 302-1) |
- |
1000 |
|
20% Discount to BIS |
| 23.4(Internal Wiring, IS 302-1) |
- |
1000 |
|
20% Discount to BIS |
| 23.5(Internal Wiring, IS 302-1) |
- |
1000 |
|
20% Discount to BIS |
| 23.6(Internal Wiring, IS 302-1) |
- |
1000 |
|
20% Discount to BIS |
| 23.7(Internal Wiring, IS 302-1) |
- |
1000 |
|
20% Discount to BIS |
| 23.8(Internal Wiring, IS 302-1) |
- |
1000 |
|
20% Discount to BIS |
| 23.9(Internal Wiring, IS 302-1) |
- |
1000 |
|
20% Discount to BIS |
| 23.10(Internal Wiring, IS 302-1) |
- |
1000 |
|
20% Discount to BIS |
| 24.1(Components, IS 302-1) |
- |
10000 |
|
20% Discount to BIS |
| 24.2(Components, IS 302-1) |
- |
1000 |
|
20% Discount to BIS |
| 24.5(Components, IS 302-1) |
- |
5000 |
|
20% Discount to BIS |
| 24.6(Components, IS 302-1) |
- |
5000 |
|
20% Discount to BIS |
| 25.1(Supply Connection and External Flexible Cords, IS 302-1) |
- |
5000 |
|
20% Discount to BIS |
| 25.5(Supply Connection and External Flexible Cords, IS 302-1) |
- |
5000 |
|
20% Discount to BIS |
| 25.6(Supply Connection and External Flexible Cords, IS 302-1) |
- |
5000 |
|
20% Discount to BIS |
| 25.7(Supply Connection and External Flexible Cords, IS 302-1) |
- |
5000 |
|
20% Discount to BIS |
| 25.8(Supply Connection and External Flexible Cords, IS 302-1) |
- |
5000 |
|
20% Discount to BIS |
| 26.9(Supply Connection and External Flexible Cords, IS 302-1) |
- |
5000 |
|
20% Discount to BIS |
| 25.1(Supply Connection and External Flexible Cords, IS 302-1) |
- |
5000 |
|
20% Discount to BIS |
| 25.11(Supply Connection and External Flexible Cords, IS 302-1) |
- |
5000 |
|
20% Discount to BIS |
| 25.12(Supply Connection and External Flexible Cords, IS 302-1) |
- |
5000 |
|
20% Discount to BIS |
| 25.13(Supply Connection and External Flexible Cords, IS 302-1) |
- |
5000 |
|
20% Discount to BIS |
| 25.14(Supply Connection and External Flexible Cords, IS 302-1) |
- |
1000 |
|
20% Discount to BIS |
| 25.14(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
-- |
| 25.15(Supply Connection and External Flexible Cords, IS 302-1) |
- |
1000 |
|
20% Discount to BIS |
| 25.16(Supply Connection and External Flexible Cords, IS 302-1) |
- |
1000 |
|
20% Discount to BIS |
| 25.17(Supply Connection and External Flexible Cords, IS 302-1) |
- |
1000 |
|
20% Discount to BIS |
| 25.18(Supply Connection and External Flexible Cords, IS 302-1) |
- |
1000 |
|
20% Discount to BIS |
| 25.19(Supply Connection and External Flexible Cords, IS 302-1) |
- |
1000 |
|
20% Discount to BIS |
| 25.2(Supply Connection and External Flexible Cords, IS 302-1) |
- |
1000 |
|
20% Discount to BIS |
| 25.21(Supply Connection and External Flexible Cords, IS 302-1) |
- |
1000 |
|
20% Discount to BIS |
| 25.22(Supply Connection and External Flexible Cords, IS 302-1) |
- |
1000 |
|
20% Discount to BIS |
| 26(Terminals for External Conductors, IS 302-1) |
- |
10000 |
|
20% Discount to BIS |
| 27(Provision for Earthing, IS 302-1) |
- |
15000 |
|
20% Discount to BIS |
| 27.2(Provision for Earthing, IS 302-1) |
- |
5000 |
|
20% Discount to BIS |
| 27.3(Provision for Earthing, IS 302-1) |
- |
5000 |
|
20% Discount to BIS |
| 27.4(Provision for Earthing, IS 302-1) |
- |
5000 |
|
20% Discount to BIS |
| 27.5(Provision for Earthing, IS 302-1) |
- |
10000 |
|
20% Discount to BIS |
| 28(Screws & Connections, IS 302-1) |
- |
10000 |
|
20% Discount to BIS |
| 29.1(Clearances, Creepage distances and Solid Insulation, IS 302-1) |
- |
10000 |
|
20% Discount to BIS |
| 29.2(Clearances, Creepage distances and Solid Insulation, IS 302-1) |
- |
15000 |
|
20% Discount to BIS |
| 30.1(Resistance to Heat and Fire, IS 302-1) |
- |
10000 |
|
20% Discount to BIS |
| 30.2(Resistance to Heat and Fire, IS 302-1) |
- |
10000 |
|
20% Discount to BIS |
| 31(Resistance of Rusting, IS 302-1) |
- |
5000 |
|
20% Discount to BIS |
| 32(Radiation, Toxicity and similar Hazard IS 302-1) |
- |
5000 |
|
20% Discount to BIS |
| 19.11.4.1(Electrostatic discharges) |
- |
15000 |
|
20% Discount to BIS |
| 19.11.4.2(Radiated fields) |
- |
40000 |
|
20% Discount to BIS |
| 19.11.4.3(Fast transient bursts) |
- |
15000 |
|
20% Discount to BIS |
| 19.11.4.4(Surge immunity test) |
- |
15000 |
|
20% Discount to BIS |
| 19.11.4.5(Immunity to conducted discharges) |
- |
15000 |
|
20% Discount to BIS |
| 19.11.4.6(Class 3 Voltage dips and interruptions) |
- |
15000 |
|
20% Discount to BIS |
| 19.11.4.7(Harmonics) |
- |
15000 |
|
20% Discount to BIS |
| 19.11.4.5(Immunity to conducted discharges) |
- |
0 |
|
-- |
| 4(GENERAL REQUIREMENTS) |
- |
0 |
|
-- |
| 5(GENERAL CONDITIONS FOR THE TESTS) |
- |
0 |
|
-- |
| 27(Provision for Earthing) |
- |
15000 |
|
20% Discount to BIS |
| 29(Clearances, Creepage distances and Solid Insulation) |
- |
15000 |
|
20% Discount to BIS |
| 6(Classification- IS 302-1 ) |
- |
10000 |
|
20% Discount to BIS |
| 6(Classification- IS 302-1) |
- |
10000 |
|
20% Discount to BIS |
| 7.1(Marking- IS 302-1) |
- |
5000 |
|
20% Discount to BIS |
| 7.1(Marking- IS 302-1) |
- |
5000 |
|
20% Discount to BIS |
| 7.1(Marking- IS 302-1) |
- |
5000 |
|
20% Discount to BIS |
| 7.1(Marking- IS 302-1) |
- |
5000 |
|
20% Discount to BIS |
| 7.1(Marking- IS 302-1) |
- |
5000 |
|
20% Discount to BIS |
| 7.1(Marking- IS 302-1) |
- |
5000 |
|
20% Discount to BIS |
| 7.1(Marking- IS 302-1) |
- |
5000 |
|
20% Discount to BIS |
| 7.1(Marking- IS 302-1) |
- |
5000 |
|
20% Discount to BIS |
| 7.3(Marking- IS 302-1) |
- |
5000 |
|
20% Discount to BIS |
| 7.4(Marking- IS 302-1) |
- |
5000 |
|
20% Discount to BIS |
| 7.6(Marking- IS 302-1) |
- |
5000 |
|
20% Discount to BIS |
| 7.7(Marking- IS 302-1) |
- |
5000 |
|
20% Discount to BIS |
| 7.8(Marking- IS 302-1) |
- |
5000 |
|
20% Discount to BIS |
| 7.11(Marking- IS 302-1) |
- |
5000 |
|
20% Discount to BIS |
| 7.12(Marking- IS 302-1) |
- |
5000 |
|
20% Discount to BIS |
| 7.13(Marking- IS 302-1) |
- |
5000 |
|
20% Discount to BIS |
| 7.14(Marking- IS 302-1) |
- |
10000 |
|
20% Discount to BIS |
| 7.15(Marking- IS 302-1) |
- |
5000 |
|
20% Discount to BIS |
| 7.101(Marking) |
- |
5000 |
|
20% Discount to BIS |
| 8( Protection Against Electric Shock, IS 302-1) |
- |
10000 |
|
20% Discount to BIS |
| 10(Power Input and Current, IS 302-1) |
- |
15000 |
|
20% Discount to BIS |
| 11(Heating, IS 302-1) |
- |
20000 |
|
20% Discount to BIS |
| 11(Heating, IS 302-1) |
- |
20000 |
|
20% Discount to BIS |
| 11(Heating, IS 302-1) |
- |
20000 |
|
20% Discount to BIS |
| 11(Heating, IS 302-1) |
- |
20000 |
|
20% Discount to BIS |
| 11(Heating, IS 302-1) |
- |
20000 |
|
20% Discount to BIS |
| 13(Electrical Insulation and Leakage Current at Operating Temperature: Leakage current, IS 302-1) |
- |
15000 |
|
20% Discount to BIS |
| 13(Electrical Insulation and Leakage Current at Operating Temperature: High Voltage, IS 302-1) |
- |
15000 |
|
20% Discount to BIS |
| 14(Transient Over Voltages, IS 302-1) |
- |
10000 |
|
20% Discount to BIS |
| 15.1(Moisture Resistance, IS 302-1) |
- |
10000 |
|
20% Discount to BIS |
| 15.2(Moisture Resistance, IS 302-1) |
- |
10000 |
|
20% Discount to BIS |
| 15(Moisture Resistance, IS 302-1) |
- |
25000 |
|
20% Discount to BIS |
| 16(Electrical Insulation and Leakage Current at Operating Temperature: Leakage current, IS 302-1) |
- |
15000 |
|
20% Discount to BIS |
| 16(Electrical Insulation and Leakage Current at Operating Temperature: High Voltage, IS 302-1) |
- |
15000 |
|
20% Discount to BIS |
| 17(Overload protection of Transformers and Associated Circuits, IS 302-1) |
- |
10000 |
|
20% Discount to BIS |
| 17(Overload protection of Transformers and Associated Circuits, IS 302-1) |
- |
10000 |
|
20% Discount to BIS |
| 19.7(Abnormal Operation, IS 302-1) |
- |
10000 |
|
20% Discount to BIS |
| 19.8(Abnormal Operation, IS 302-1) |
- |
10000 |
|
20% Discount to BIS |
| 19.9(Abnormal Operation, IS 302-1) |
- |
15000 |
|
20% Discount to BIS |
| 19.1(Abnormal Operation, IS 302-1) |
- |
10000 |
|
20% Discount to BIS |
| 19.101(Abnormal Operation) |
- |
10000 |
|
20% Discount to BIS |
| 19.102(Abnormal Operation) |
- |
10000 |
|
20% Discount to BIS |
| 20.1(Stability & Mechanical Hazards, IS 302-1) |
- |
10000 |
|
20% Discount to BIS |
| 20.2(Stability & Mechanical Hazards, IS 302-1) |
- |
10000 |
|
20% Discount to BIS |
| 20.101(Stability & Mechanical Hazards) |
- |
10000 |
|
20% Discount to BIS |
| 20.102(Stability & Mechanical Hazards) |
- |
5000 |
|
20% Discount to BIS |
| 20.103(Stability & Mechanical Hazards) |
- |
5000 |
|
20% Discount to BIS |
| 20.104(Stability & Mechanical Hazards) |
- |
5000 |
|
20% Discount to BIS |
| 20.105(Stability & Mechanical Hazards) |
- |
5000 |
|
20% Discount to BIS |
| 20.106(Stability & Mechanical Hazards) |
- |
5000 |
|
20% Discount to BIS |
| 20.107(Stability & Mechanical Hazards) |
- |
5000 |
|
20% Discount to BIS |
| 20.108(Stability & Mechanical Hazards) |
- |
5000 |
|
20% Discount to BIS |
| 20.109(Stability & Mechanical Hazards) |
- |
5000 |
|
20% Discount to BIS |
| 20.110(Stability & Mechanical Hazards) |
- |
5000 |
|
20% Discount to BIS |
| 20.111(Stability & Mechanical Hazards) |
- |
5000 |
|
20% Discount to BIS |
| 20.112(Stability & Mechanical Hazards) |
- |
5000 |
|
20% Discount to BIS |
| 20.113(Stability & Mechanical Hazards) |
- |
5000 |
|
20% Discount to BIS |
| 20.114(Stability & Mechanical Hazards) |
- |
5000 |
|
20% Discount to BIS |
| 20.115(Stability & Mechanical Hazards) |
- |
5000 |
|
20% Discount to BIS |
| 20.116(Stability & Mechanical Hazards) |
- |
5000 |
|
20% Discount to BIS |
| 21.1(Mechanical Strength, IS 302-1) |
- |
5000 |
|
20% Discount to BIS |
| 21.2(Mechanical Strength, IS 302-1) |
- |
5000 |
|
20% Discount to BIS |
| 22(Construction, IS 302-1) |
- |
5000 |
|
20% Discount to BIS |
| 22.101(Construction) |
- |
5000 |
|
20% Discount to BIS |
| 22.102(Construction) |
- |
10000 |
|
20% Discount to BIS |
| 23.1(Internal Wiring, IS 302-1) |
- |
10000 |
|
20% Discount to BIS |
| 23.2(Internal Wiring, IS 302-1) |
- |
10000 |
|
20% Discount to BIS |
| 23.3(Internal Wiring, IS 302-1) |
- |
10000 |
|
20% Discount to BIS |
| 23.4(Internal Wiring, IS 302-1) |
- |
5000 |
|
20% Discount to BIS |
| 23.5(Internal Wiring, IS 302-1) |
- |
5000 |
|
20% Discount to BIS |
| 23.6(Internal Wiring, IS 302-1) |
- |
5000 |
|
20% Discount to BIS |
| 23.7(Internal Wiring, IS 302-1) |
- |
5000 |
|
20% Discount to BIS |
| 23.8(Internal Wiring, IS 302-1) |
- |
5000 |
|
20% Discount to BIS |
| 23.9(Internal Wiring, IS 302-1) |
- |
5000 |
|
20% Discount to BIS |
| 23.10(Internal Wiring, IS 302-1) |
- |
5000 |
|
20% Discount to BIS |
| 24.1(Components, IS 302-1) |
- |
10000 |
|
20% Discount to BIS |
| 24.2(Components, IS 302-1) |
- |
10000 |
|
20% Discount to BIS |
| 24.5(Components, IS 302-1) |
- |
10000 |
|
20% Discount to BIS |
| 24.6(Components, IS 302-1) |
- |
10000 |
|
20% Discount to BIS |
| 25.1(Supply Connection and External Flexible Cords, IS 302-1) |
- |
10000 |
|
20% Discount to BIS |
| 25.5(Supply Connection and External Flexible Cords, IS 302-1) |
- |
10000 |
|
20% Discount to BIS |
| 25.6(Supply Connection and External Flexible Cords, IS 302-1) |
- |
10000 |
|
20% Discount to BIS |
| 25.7(Supply Connection and External Flexible Cords, IS 302-1) |
- |
10000 |
|
20% Discount to BIS |
| 25.8(Supply Connection and External Flexible Cords, IS 302-1) |
- |
10000 |
|
20% Discount to BIS |
| 26.9(Supply Connection and External Flexible Cords, IS 302-1) |
- |
10000 |
|
20% Discount to BIS |
| 25.1(Supply Connection and External Flexible Cords, IS 302-1) |
- |
10000 |
|
20% Discount to BIS |
| 25.11(Supply Connection and External Flexible Cords, IS 302-1) |
- |
10000 |
|
20% Discount to BIS |
| 25.12(Supply Connection and External Flexible Cords, IS 302-1) |
- |
10000 |
|
20% Discount to BIS |
| 25.13(Supply Connection and External Flexible Cords, IS 302-1) |
- |
10000 |
|
20% Discount to BIS |
| 25.14(Supply Connection and External Flexible Cords, IS 302-1) |
- |
10000 |
|
20% Discount to BIS |
| 25.14(Supply Connection and External Flexible Cords, IS 302-1) |
- |
10000 |
|
20% Discount to BIS |
| 25.15(Supply Connection and External Flexible Cords, IS 302-1) |
- |
10000 |
|
20% Discount to BIS |
| 25.16(Supply Connection and External Flexible Cords, IS 302-1) |
- |
10000 |
|
20% Discount to BIS |
| 25.17(Supply Connection and External Flexible Cords, IS 302-1) |
- |
10000 |
|
20% Discount to BIS |
| 25.18(Supply Connection and External Flexible Cords, IS 302-1) |
- |
10000 |
|
20% Discount to BIS |
| 25.19(Supply Connection and External Flexible Cords, IS 302-1) |
- |
5000 |
|
20% Discount to BIS |
| 25.2(Supply Connection and External Flexible Cords, IS 302-1) |
- |
5000 |
|
20% Discount to BIS |
| 25.21(Supply Connection and External Flexible Cords, IS 302-1) |
- |
5000 |
|
20% Discount to BIS |
| 25.22(Supply Connection and External Flexible Cords, IS 302-1) |
- |
5000 |
|
20% Discount to BIS |
| 26(Terminals for External Conductors, IS 302-1) |
- |
5000 |
|
20% Discount to BIS |
| 27(Provision for Earthing, IS 302-1) |
- |
15000 |
|
20% Discount to BIS |
| 27.2(Provision for Earthing, IS 302-1) |
- |
10000 |
|
20% Discount to BIS |
| 27.3(Provision for Earthing, IS 302-1) |
- |
10000 |
|
20% Discount to BIS |
| 27.4(Provision for Earthing, IS 302-1) |
- |
10000 |
|
20% Discount to BIS |
| 27.5(Provision for Earthing, IS 302-1) |
- |
15000 |
|
20% Discount to BIS |
| 28(Screws & Connections, IS 302-1) |
- |
10000 |
|
20% Discount to BIS |
| 29.1(Clearances, Creepage distances and Solid Insulation, IS 302-1) |
- |
10000 |
|
20% Discount to BIS |
| 29.2(Clearances, Creepage distances and Solid Insulation, IS 302-1) |
- |
15000 |
|
20% Discount to BIS |
| 30.1(Resistance to Heat and Fire, IS 302-1) |
- |
15000 |
|
20% Discount to BIS |
| 30.2(Resistance to Heat and Fire, IS 302-1) |
- |
15000 |
|
20% Discount to BIS |
| 31(Resistance of Rusting, IS 302-1) |
- |
10000 |
|
20% Discount to BIS |
| 32(Radiation, Toxicity and similar Hazard IS 302-1) |
- |
5000 |
|
20% Discount to BIS |
| 19.11.4.1(Electrostatic discharges) |
- |
15000 |
|
20% Discount to BIS |
| 19.11.4.2(Radiated fields) |
- |
40000 |
|
20% Discount to BIS |
| 19.11.4.3(Fast transient bursts) |
- |
15000 |
|
20% Discount to BIS |
| 19.11.4.4(Surge immunity test) |
- |
15000 |
|
20% Discount to BIS |
| 19.11.4.5(Immunity to conducted discharges) |
- |
15000 |
|
20% Discount to BIS |
| 19.11.4.6(Class 3 Voltage dips and interruptions) |
- |
15000 |
|
20% Discount to BIS |
| 19.11.4.7(Harmonics) |
- |
15000 |
|
20% Discount to BIS |
| 19.11.4.5(Immunity to conducted discharges) |
- |
15000 |
|
20% Discount to BIS |
| 4(GENERAL REQUIREMENTS) |
- |
5000 |
|
- |
| 5(GENERAL CONDITIONS FOR THE TESTS) |
- |
5000 |
|
- |
| 27(Provision for Earthing) |
- |
15000 |
|
20% Discount to BIS |
| 29(Clearances, Creepage distances and Solid Insulation) |
- |
15000 |
|
20% Discount to BIS |
| 6(Classification- IS 302-1 ) |
- |
0 |
|
- |
| 6(Classification- IS 302-1) |
- |
0 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.1(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.3(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.4(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.6(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.7(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.8(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.11(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.12(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.13(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.14(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.15(Marking- IS 302-1) |
- |
0 |
|
- |
| 7.101(Marking) |
- |
0 |
|
- |
| 8( Protection Against Electric Shock, IS 302-1) |
- |
0 |
|
- |
| 10(Power Input and Current, IS 302-1) |
- |
0 |
|
- |
| 11(Heating, IS 302-1) |
- |
0 |
|
- |
| 11(Heating, IS 302-1) |
- |
0 |
|
- |
| 11(Heating, IS 302-1) |
- |
0 |
|
- |
| 11(Heating, IS 302-1) |
- |
0 |
|
- |
| 11(Heating, IS 302-1) |
- |
0 |
|
- |
| 13(Electrical Insulation and Leakage Current at Operating Temperature: Leakage current, IS 302-1) |
- |
0 |
|
- |
| 13(Electrical Insulation and Leakage Current at Operating Temperature: High Voltage, IS 302-1) |
- |
0 |
|
- |
| 14(Transient Over Voltages, IS 302-1) |
- |
0 |
|
- |
| 15.1(Moisture Resistance, IS 302-1) |
- |
0 |
|
- |
| 15.2(Moisture Resistance, IS 302-1) |
- |
0 |
|
- |
| 15(Moisture Resistance, IS 302-1) |
- |
0 |
|
- |
| 16(Electrical Insulation and Leakage Current at Operating Temperature: Leakage current, IS 302-1) |
- |
0 |
|
- |
| 16(Electrical Insulation and Leakage Current at Operating Temperature: High Voltage, IS 302-1) |
- |
0 |
|
- |
| 17(Overload protection of Transformers and Associated Circuits, IS 302-1) |
- |
0 |
|
- |
| 17(Overload protection of Transformers and Associated Circuits, IS 302-1) |
- |
0 |
|
- |
| 19.7(Abnormal Operation, IS 302-1) |
- |
0 |
|
- |
| 19.8(Abnormal Operation, IS 302-1) |
- |
0 |
|
- |
| 19.9(Abnormal Operation, IS 302-1) |
- |
0 |
|
- |
| 19.1(Abnormal Operation, IS 302-1) |
- |
0 |
|
- |
| 19.101(Abnormal Operation) |
- |
0 |
|
- |
| 19.102(Abnormal Operation) |
- |
0 |
|
- |
| 20.1(Stability & Mechanical Hazards, IS 302-1) |
- |
0 |
|
- |
| 20.2(Stability & Mechanical Hazards, IS 302-1) |
- |
0 |
|
- |
| 20.101(Stability & Mechanical Hazards) |
- |
0 |
|
- |
| 20.102(Stability & Mechanical Hazards) |
- |
0 |
|
- |
| 20.103(Stability & Mechanical Hazards) |
- |
0 |
|
- |
| 20.104(Stability & Mechanical Hazards) |
- |
0 |
|
- |
| 20.105(Stability & Mechanical Hazards) |
- |
0 |
|
- |
| 20.106(Stability & Mechanical Hazards) |
- |
0 |
|
- |
| 20.107(Stability & Mechanical Hazards) |
- |
0 |
|
- |
| 20.108(Stability & Mechanical Hazards) |
- |
0 |
|
- |
| 20.109(Stability & Mechanical Hazards) |
- |
0 |
|
- |
| 20.110(Stability & Mechanical Hazards) |
- |
0 |
|
- |
| 20.111(Stability & Mechanical Hazards) |
- |
0 |
|
- |
| 20.112(Stability & Mechanical Hazards) |
- |
0 |
|
- |
| 20.113(Stability & Mechanical Hazards) |
- |
0 |
|
- |
| 20.114(Stability & Mechanical Hazards) |
- |
0 |
|
- |
| 20.115(Stability & Mechanical Hazards) |
- |
0 |
|
- |
| 20.116(Stability & Mechanical Hazards) |
- |
0 |
|
- |
| 21.1(Mechanical Strength, IS 302-1) |
- |
0 |
|
- |
| 21.2(Mechanical Strength, IS 302-1) |
- |
0 |
|
- |
| 22(Construction, IS 302-1) |
- |
0 |
|
- |
| 22.101(Construction) |
- |
0 |
|
- |
| 22.102(Construction) |
- |
0 |
|
- |
| 23.1(Internal Wiring, IS 302-1) |
- |
0 |
|
- |
| 23.2(Internal Wiring, IS 302-1) |
- |
0 |
|
- |
| 23.3(Internal Wiring, IS 302-1) |
- |
0 |
|
- |
| 23.4(Internal Wiring, IS 302-1) |
- |
0 |
|
- |
| 23.5(Internal Wiring, IS 302-1) |
- |
0 |
|
- |
| 23.6(Internal Wiring, IS 302-1) |
- |
0 |
|
- |
| 23.7(Internal Wiring, IS 302-1) |
- |
0 |
|
- |
| 23.8(Internal Wiring, IS 302-1) |
- |
0 |
|
- |
| 23.9(Internal Wiring, IS 302-1) |
- |
0 |
|
- |
| 23.10(Internal Wiring, IS 302-1) |
- |
0 |
|
- |
| 24.1(Components, IS 302-1) |
- |
0 |
|
- |
| 24.2(Components, IS 302-1) |
- |
0 |
|
- |
| 24.5(Components, IS 302-1) |
- |
0 |
|
- |
| 24.6(Components, IS 302-1) |
- |
0 |
|
- |
| 25.1(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.5(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.6(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.7(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.8(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 26.9(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.1(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.11(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.12(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.13(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.14(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.14(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.15(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.16(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.17(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.18(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.19(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.2(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.21(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.22(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 26(Terminals for External Conductors, IS 302-1) |
- |
0 |
|
- |
| 27(Provision for Earthing, IS 302-1) |
- |
0 |
|
- |
| 27.2(Provision for Earthing, IS 302-1) |
- |
0 |
|
- |
| 27.3(Provision for Earthing, IS 302-1) |
- |
0 |
|
- |
| 27.4(Provision for Earthing, IS 302-1) |
- |
0 |
|
- |
| 27.5(Provision for Earthing, IS 302-1) |
- |
0 |
|
- |
| 28(Screws & Connections, IS 302-1) |
- |
0 |
|
- |
| 29.1(Clearances, Creepage distances and Solid Insulation, IS 302-1) |
- |
0 |
|
- |
| 29.2(Clearances, Creepage distances and Solid Insulation, IS 302-1) |
- |
0 |
|
- |
| 30.1(Resistance to Heat and Fire, IS 302-1) |
- |
0 |
|
- |
| 30.2(Resistance to Heat and Fire, IS 302-1) |
- |
0 |
|
- |
| 31(Resistance of Rusting, IS 302-1) |
- |
0 |
|
- |
| 32(Radiation, Toxicity and similar Hazard IS 302-1) |
- |
0 |
|
- |
| 19.11.4.1(Electrostatic discharges) |
- |
0 |
|
- |
| 19.11.4.2(Radiated fields) |
- |
0 |
|
- |
| 19.11.4.3(Fast transient bursts) |
- |
0 |
|
- |
| 19.11.4.4(Surge immunity test) |
- |
0 |
|
- |
| 19.11.4.5(Immunity to conducted discharges) |
- |
0 |
|
- |
| 19.11.4.6(Class 3 Voltage dips and interruptions) |
- |
0 |
|
- |
| 19.11.4.7(Harmonics) |
- |
0 |
|
- |
| 19.11.4.5(Immunity to conducted discharges) |
- |
0 |
|
- |
| 4(GENERAL REQUIREMENTS) |
- |
0 |
|
- |
| 5(GENERAL CONDITIONS FOR THE TESTS) |
- |
0 |
|
- |
| 27(Provision for Earthing) |
- |
0 |
|
- |
| 29(Clearances, Creepage distances and Solid Insulation) |
- |
0 |
|
- |
|
11 Sep, 2027 |
- Included w.e.f 27.11.2025
Exclusion: Cl. 22.16 (Automatic cord reels), Cl. 22.32 (Resistant to ageing test), Cl. 22.48 (Appliances to be connected to the water mains), Cl. 8.1.4 (Measurements of electric charge, Energy discharge measurement in mJ), Cl. 23.3 (Flexing Test), Cl. 24.1.1 (Capacitor Test), Cl. 24.1.3 (Switching Cycle Operation Test), Cl. 24.1.4 (Automatic Control Cycle Operation Test), Cl. 24.1.5 (Appliance Coupler and Interconnection Coupler Test), Cl. 24.1.6 (Lamp Holder Test), Cl. 24.5 (Capacitor in Auxiliary Winding of Motor Test), Cl. 24.6 (Motors Basic Insulation Test), Cl.25.7 (cold bend and cold impact test) |
| 4 |
IS 302 : Part 1 (2024) |
Household and Similar Electrical Appliances — Safety Part 1 General Requirements (Seventh Revision) |
- |
150000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6(Classification- IS 302-1) |
- |
10000 |
|
20% Discount to BIS |
| 5(General conditions for the tests) |
- |
100 |
|
20% Discount to BIS |
| 12(Charging of metal-ion batteries) |
- |
0 |
|
-- |
| 19.11.4.7(Harmonics) |
- |
15000 |
|
20% Discount to BIS |
| 19.11.4.6(Class 3 Voltage dips and interruptions) |
- |
15000 |
|
20% Discount to BIS |
| 19.11.4.5(Immunity to conducted discharges) |
- |
15000 |
|
20% Discount to BIS |
| 19.11.4.4(Surge immunity test) |
- |
15000 |
|
20% Discount to BIS |
| 19.11.4.3(Fast transient bursts) |
- |
15000 |
|
20% Discount to BIS |
| 19.11.4.2(Radiated fields) |
- |
40000 |
|
20% Discount to BIS |
| 19.11.4.1(Electrostatic discharges) |
- |
15000 |
|
20% Discount to BIS |
| 11.8(Temperature rise) |
- |
15000 |
|
20% Discount to BIS |
| 11.7(Duration corresponding) |
- |
5000 |
|
20% Discount to BIS |
| 11.6(Combined appliances) |
- |
10000 |
|
20% Discount to BIS |
| 11.5(Motor-operated appliances) |
- |
10000 |
|
20% Discount to BIS |
| 11.4(Heating appliances) |
- |
10000 |
|
20% Discount to BIS |
| 8.1.5(Live parts of built-in appliances) |
- |
5000 |
|
20% Discount to BIS |
| 18(Endurance) |
- |
0 |
|
- |
| 17(Overload protection of transformers and associated circuits) |
- |
10000 |
|
20% Discount to BIS |
| 16(Leakage current and electric strength) |
- |
10000 |
|
20% Discount to BIS |
| 4(General requirement) |
- |
0 |
|
20% Discount to BIS |
| 32.1(Radiation Toxicity and Similar Hazards) |
- |
1000 |
|
20% Discount to BIS |
| 31(Resistance to Rusting) |
- |
1000 |
|
20% Discount to BIS |
| 30.2(Needle Flame Test) |
- |
10000 |
|
20% Discount to BIS |
| 30.2(Glow Wire Test) |
- |
10000 |
|
20% Discount to BIS |
| 30.1(Ball pressure test) |
- |
10000 |
|
20% Discount to BIS |
| 29(clearance, creepage distances and solid insulation) |
- |
10000 |
|
20% Discount to BIS |
| 28(Screw test and connections) |
- |
5000 |
|
20% Discount to BIS |
| 27.1(Provision for Earthing, IS 302-1) |
- |
10000 |
|
20% Discount to BIS |
| 26(Terminals for external conductors) |
- |
5000 |
|
20% Discount to BIS |
| 25.8(Supply Connection and External Flexible Cords, IS 302-1) |
- |
5000 |
|
20% Discount to BIS |
| 24(Components) |
- |
5000 |
|
20% Discount to BIS |
| 23.1(Internal Wiring, IS 302-1) |
- |
10000 |
|
20% Discount to BIS |
| 22.1(Construction, IS 302-1) |
- |
15000 |
|
20% Discount to BIS |
| 21.1(Mechanical Strength, IS 302-1) |
- |
10000 |
|
20% Discount to BIS |
| 20.1(Stability & Mechanical Hazards, IS 302-1) |
- |
10000 |
|
20% Discount to BIS |
| 19(Abnormal Operation) |
- |
25000 |
|
20% Discount to BIS |
| 18(Endurance) |
- |
0 |
|
- |
| 17(Over Load Protection of Transformers and associated circuits) |
- |
10000 |
|
20% Discount to BIS |
| 16.3(Electric Strength (after clause 15 and 16.2)) |
- |
0 |
|
- |
| 16.2(Leakage Current (after Clause 15)) |
- |
0 |
|
- |
| 16.1(General) |
- |
0 |
|
- |
| 16.0(General) |
- |
0 |
|
- |
| 15.3(Humidity Test) |
- |
15000 |
|
20% Discount to BIS |
| 15.2(Spillage Test) |
- |
5000 |
|
20% Discount to BIS |
| 15.1(Ingress Protection test other than IPX0 (IP test)) |
- |
5000 |
|
20% Discount to BIS |
| 15.0(Moisture resistance) |
- |
5000 |
|
20% Discount to BIS |
| 14(Transient Over Voltages) |
- |
5000 |
|
20% Discount to BIS |
| 13.3(Electric Strength at operating temperature) |
- |
5000 |
|
20% Discount to BIS |
| 13.2(Leakage current at operating temperature) |
- |
5000 |
|
20% Discount to BIS |
| 13(Leakage current and electric strength at operating temperature) |
- |
5000 |
|
20% Discount to BIS |
| 11.3(Heating) |
- |
5000 |
|
20% Discount to BIS |
| 11.2(General) |
- |
5000 |
|
20% Discount to BIS |
| 11.1(General) |
- |
1000 |
|
20% Discount to BIS |
| 10.2(Current input) |
- |
10000 |
|
20% Discount to BIS |
| 10.1(Power input) |
- |
10000 |
|
20% Discount to BIS |
| 9(Starting of motor operation test requirements and tests) |
- |
0 |
|
- |
| 8.1.4(Protection against live parts against protective impedance) |
- |
1000 |
|
20% Discount to BIS |
| 8.1.3(Protection against live parts in visible glowing heating elements) |
- |
1000 |
|
20% Discount to BIS |
| 8.1.2(Protection against live parts in openings) |
- |
1000 |
|
20% Discount to BIS |
| 8.1.1(Protection against live parts in all positions) |
- |
1000 |
|
20% Discount to BIS |
| 7(Marking and instructions) |
- |
5000 |
|
20% Discount to BIS |
| A.2(Earth continuity test) |
- |
0 |
|
- |
| Annex C(Ageing test on motors) |
- |
0 |
|
- |
| Annex D(Thermal motor protectors) |
- |
0 |
|
- |
| 15.2(Moisture resistance) |
- |
0 |
|
- |
| 19.17(Abnormal Operation, IS 302-1) |
- |
10000 |
|
20% Discount to BIS |
| 20.2(Stability & Mechanical Hazards, IS 302-1) |
- |
5000 |
|
20% Discount to BIS |
| 21.2(Mechanical Strength, IS 302-1) |
- |
5000 |
|
- |
| 21.3(Mechanical Strength, IS 302-1) |
- |
1000 |
|
20% Discount to BIS |
| 22.5(Construction) |
- |
1000 |
|
20% Discount to BIS |
| 22.6(Construction, IS 302-1) |
- |
1000 |
|
20% Discount to BIS |
| 22.11(Construction, IS 302-1) |
- |
1000 |
|
20% Discount to BIS |
| 22.16(Construction) |
- |
0 |
|
- |
| 22.32(Construction, IS 302-1) |
- |
0 |
|
- |
| 22.42(Construction) |
- |
1000 |
|
20% Discount to BIS |
| 23.3(Internal Wiring, IS 302-1) |
- |
0 |
|
- |
| 25.6(Supply connection and external flexible cords, IS 302-1) |
- |
10000 |
|
20% Discount to BIS |
| 25.7(Supply Connection and External Flexible Cords, IS 302-1) |
- |
1000 |
|
20% Discount to BIS |
| 25.14(Supply Connection and External Flexible Cords, IS 302-1) |
- |
1000 |
|
20% Discount to BIS |
| 25.15(Supply Connection and External Flexible Cords, IS 302-1) |
- |
1000 |
|
20% Discount to BIS |
| 26.5(Terminals for external conductors) |
- |
1000 |
|
20% Discount to BIS |
| 27.5(Provision for Earthing, IS 302-1) |
- |
10000 |
|
20% Discount to BIS |
| 28.1(Screws and connections) |
- |
1000 |
|
20% Discount to BIS |
| 22.2(Construction, IS 302-1) |
- |
0 |
|
- |
| 22.3(Construction, IS 302-1) |
- |
0 |
|
- |
| B.22.4(Construction, IS 302-1) |
- |
0 |
|
- |
| B.22.5(Construction, IS 302-1) |
- |
0 |
|
- |
| 6(Classification- IS 302-1) |
- |
0 |
|
- |
| 5(General conditions for the tests) |
- |
0 |
|
- |
| 12(Charging of metal-ion batteries) |
- |
0 |
|
- |
| 19.11.4.7(Harmonics) |
- |
0 |
|
- |
| 19.11.4.6(Class 3 Voltage dips and interruptions) |
- |
0 |
|
- |
| 19.11.4.5(Immunity to conducted discharges) |
- |
0 |
|
- |
| 19.11.4.4(Surge immunity test) |
- |
0 |
|
- |
| 19.11.4.3(Fast transient bursts) |
- |
0 |
|
- |
| 19.11.4.2(Radiated fields) |
- |
0 |
|
- |
| 19.11.4.1(Electrostatic discharges) |
- |
0 |
|
- |
| 11.8(Temperature rise) |
- |
0 |
|
- |
| 11.7(Duration corresponding) |
- |
0 |
|
- |
| 11.6(Combined appliances) |
- |
0 |
|
- |
| 11.5(Motor-operated appliances) |
- |
0 |
|
- |
| 11.4(Heating appliances) |
- |
0 |
|
- |
| 8.1.5(Live parts of built-in appliances) |
- |
0 |
|
- |
| 18(Endurance) |
- |
0 |
|
- |
| 17(Overload protection of transformers and associated circuits) |
- |
0 |
|
- |
| 16(Leakage current and electric strength) |
- |
0 |
|
- |
| 4(General requirement) |
- |
0 |
|
- |
| 32.1(Radiation Toxicity and Similar Hazards) |
- |
0 |
|
- |
| 31(Resistance to Rusting) |
- |
0 |
|
- |
| 30.2(Needle Flame Test) |
- |
0 |
|
- |
| 30.2(Glow Wire Test) |
- |
0 |
|
- |
| 30.1(Ball pressure test) |
- |
0 |
|
- |
| 29(clearance, creepage distances and solid insulation) |
- |
0 |
|
- |
| 28(Screw test and connections) |
- |
0 |
|
- |
| 27.1(Provision for Earthing, IS 302-1) |
- |
0 |
|
- |
| 26(Terminals for external conductors) |
- |
0 |
|
- |
| 25.8(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 24(Components) |
- |
0 |
|
- |
| 23.1(Internal Wiring, IS 302-1) |
- |
0 |
|
- |
| 22.1(Construction, IS 302-1) |
- |
0 |
|
- |
| 21.1(Mechanical Strength, IS 302-1) |
- |
0 |
|
- |
| 20.1(Stability & Mechanical Hazards, IS 302-1) |
- |
0 |
|
- |
| 19(Abnormal Operation) |
- |
0 |
|
- |
| 18(Endurance) |
- |
0 |
|
- |
| 17(Over Load Protection of Transformers and associated circuits) |
- |
0 |
|
- |
| 16.3(Electric Strength (after clause 15 and 16.2)) |
- |
0 |
|
- |
| 16.2(Leakage Current (after Clause 15)) |
- |
0 |
|
- |
| 16.1(General) |
- |
0 |
|
- |
| 16.0(General) |
- |
0 |
|
- |
| 15.3(Humidity Test) |
- |
0 |
|
- |
| 15.2(Spillage Test) |
- |
0 |
|
- |
| 15.1(Ingress Protection test other than IPX0 (IP test)) |
- |
0 |
|
- |
| 15.0(Moisture resistance) |
- |
0 |
|
- |
| 14(Transient Over Voltages) |
- |
0 |
|
- |
| 13.3(Electric Strength at operating temperature) |
- |
0 |
|
- |
| 13.2(Leakage current at operating temperature) |
- |
0 |
|
- |
| 13(Leakage current and electric strength at operating temperature) |
- |
0 |
|
- |
| 11.3(Heating) |
- |
0 |
|
- |
| 11.2(General) |
- |
0 |
|
- |
| 11.1(General) |
- |
0 |
|
- |
| 10.2(Current input) |
- |
0 |
|
- |
| 10.1(Power input) |
- |
0 |
|
- |
| 9(Starting of motor operation test requirements and tests) |
- |
0 |
|
- |
| 8.1.4(Protection against live parts against protective impedance) |
- |
0 |
|
- |
| 8.1.3(Protection against live parts in visible glowing heating elements) |
- |
0 |
|
- |
| 8.1.2(Protection against live parts in openings) |
- |
0 |
|
- |
| 8.1.1(Protection against live parts in all positions) |
- |
0 |
|
- |
| 7(Marking and instructions) |
- |
0 |
|
- |
| A.2(Earth continuity test) |
- |
0 |
|
- |
| Annex C(Ageing test on motors) |
- |
0 |
|
- |
| Annex D(Thermal motor protectors) |
- |
0 |
|
- |
| 15.2(Moisture resistance) |
- |
0 |
|
- |
| 19.17(Abnormal Operation, IS 302-1) |
- |
0 |
|
- |
| 20.2(Stability & Mechanical Hazards, IS 302-1) |
- |
0 |
|
- |
| 21.2(Mechanical Strength, IS 302-1) |
- |
0 |
|
- |
| 21.3(Mechanical Strength, IS 302-1) |
- |
0 |
|
- |
| 22.5(Construction) |
- |
0 |
|
- |
| 22.6(Construction, IS 302-1) |
- |
0 |
|
- |
| 22.11(Construction, IS 302-1) |
- |
0 |
|
- |
| 22.16(Construction) |
- |
0 |
|
- |
| 22.32(Construction, IS 302-1) |
- |
0 |
|
- |
| 22.42(Construction) |
- |
0 |
|
- |
| 23.3(Internal Wiring, IS 302-1) |
- |
0 |
|
- |
| 25.6(Supply connection and external flexible cords, IS 302-1) |
- |
0 |
|
- |
| 25.7(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.14(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 25.15(Supply Connection and External Flexible Cords, IS 302-1) |
- |
0 |
|
- |
| 26.5(Terminals for external conductors) |
- |
0 |
|
- |
| 27.5(Provision for Earthing, IS 302-1) |
- |
0 |
|
- |
| 28.1(Screws and connections) |
- |
0 |
|
- |
| 22.2(Construction, IS 302-1) |
- |
0 |
|
- |
| 22.3(Construction, IS 302-1) |
- |
0 |
|
- |
| B.22.4(Construction, IS 302-1) |
- |
0 |
|
- |
| B.22.5(Construction, IS 302-1) |
- |
0 |
|
- |
| 6(Classification- IS 302-1) |
- |
- |
|
- |
| 5(General conditions for the tests) |
- |
- |
|
- |
| 12(Charging of metal-ion batteries) |
- |
- |
|
- |
| 19.11.4.7(Harmonics) |
- |
- |
|
- |
| 19.11.4.6(Class 3 Voltage dips and interruptions) |
- |
- |
|
- |
| 19.11.4.5(Immunity to conducted discharges) |
- |
- |
|
- |
| 19.11.4.4(Surge immunity test) |
- |
- |
|
- |
| 19.11.4.3(Fast transient bursts) |
- |
- |
|
- |
| 19.11.4.2(Radiated fields) |
- |
- |
|
- |
| 19.11.4.1(Electrostatic discharges) |
- |
- |
|
- |
| 11.8(Temperature rise) |
- |
- |
|
- |
| 11.7(Duration corresponding) |
- |
- |
|
- |
| 11.6(Combined appliances) |
- |
- |
|
- |
| 11.5(Motor-operated appliances) |
- |
- |
|
- |
| 11.4(Heating appliances) |
- |
- |
|
- |
| 8.1.5(Live parts of built-in appliances) |
- |
- |
|
- |
| 18(Endurance) |
- |
- |
|
- |
| 17(Overload protection of transformers and associated circuits) |
- |
- |
|
- |
| 16(Leakage current and electric strength) |
- |
- |
|
- |
| 4(General requirement) |
- |
- |
|
- |
| 32.1(Radiation Toxicity and Similar Hazards) |
- |
- |
|
- |
| 31(Resistance to Rusting) |
- |
- |
|
- |
| 30.2(Needle Flame Test) |
- |
- |
|
- |
| 30.2(Glow Wire Test) |
- |
- |
|
- |
| 30.1(Ball pressure test) |
- |
- |
|
- |
| 29(clearance, creepage distances and solid insulation) |
- |
- |
|
- |
| 28(Screw test and connections) |
- |
- |
|
- |
| 27.1(Provision for Earthing, IS 302-1) |
- |
- |
|
- |
| 26(Terminals for external conductors) |
- |
- |
|
- |
| 25.8(Supply Connection and External Flexible Cords, IS 302-1) |
- |
- |
|
- |
| 24(Components) |
- |
- |
|
- |
| 23.1(Internal Wiring, IS 302-1) |
- |
- |
|
- |
| 22.1(Construction, IS 302-1) |
- |
- |
|
- |
| 21.1(Mechanical Strength, IS 302-1) |
- |
- |
|
- |
| 20.1(Stability & Mechanical Hazards, IS 302-1) |
- |
- |
|
- |
| 19(Abnormal Operation) |
- |
- |
|
- |
| 18(Endurance) |
- |
- |
|
- |
| 17(Over Load Protection of Transformers and associated circuits) |
- |
- |
|
- |
| 16.3(Electric Strength (after clause 15 and 16.2)) |
- |
- |
|
- |
| 16.2(Leakage Current (after Clause 15)) |
- |
- |
|
- |
| 16.1(General) |
- |
- |
|
- |
| 16.0(General) |
- |
- |
|
- |
| 15.3(Humidity Test) |
- |
- |
|
- |
| 15.2(Spillage Test) |
- |
- |
|
- |
| 15.1(Ingress Protection test other than IPX0 (IP test)) |
- |
- |
|
- |
| 15.0(Moisture resistance) |
- |
- |
|
- |
| 14(Transient Over Voltages) |
- |
- |
|
- |
| 13.3(Electric Strength at operating temperature) |
- |
- |
|
- |
| 13.2(Leakage current at operating temperature) |
- |
- |
|
- |
| 13(Leakage current and electric strength at operating temperature) |
- |
- |
|
- |
| 11.3(Heating) |
- |
- |
|
- |
| 11.2(General) |
- |
- |
|
- |
| 11.1(General) |
- |
- |
|
- |
| 10.2(Current input) |
- |
- |
|
- |
| 10.1(Power input) |
- |
- |
|
- |
| 9(Starting of motor operation test requirements and tests) |
- |
- |
|
- |
| 8.1.4(Protection against live parts against protective impedance) |
- |
- |
|
- |
| 8.1.3(Protection against live parts in visible glowing heating elements) |
- |
- |
|
- |
| 8.1.2(Protection against live parts in openings) |
- |
- |
|
- |
| 8.1.1(Protection against live parts in all positions) |
- |
- |
|
- |
| 7(Marking and instructions) |
- |
- |
|
- |
| A.2(Earth continuity test) |
- |
- |
|
- |
| Annex C(Ageing test on motors) |
- |
- |
|
- |
| Annex D(Thermal motor protectors) |
- |
- |
|
- |
| 15.2(Moisture resistance) |
- |
- |
|
- |
| 19.17(Abnormal Operation, IS 302-1) |
- |
- |
|
- |
| 20.2(Stability & Mechanical Hazards, IS 302-1) |
- |
- |
|
- |
| 21.2(Mechanical Strength, IS 302-1) |
- |
- |
|
- |
| 21.3(Mechanical Strength, IS 302-1) |
- |
- |
|
- |
| 22.5(Construction) |
- |
- |
|
- |
| 22.6(Construction, IS 302-1) |
- |
- |
|
- |
| 22.11(Construction, IS 302-1) |
- |
- |
|
- |
| 22.16(Construction) |
- |
- |
|
- |
| 22.32(Construction, IS 302-1) |
- |
- |
|
- |
| 22.42(Construction) |
- |
- |
|
- |
| 23.3(Internal Wiring, IS 302-1) |
- |
- |
|
- |
| 25.6(Supply connection and external flexible cords, IS 302-1) |
- |
- |
|
- |
| 25.7(Supply Connection and External Flexible Cords, IS 302-1) |
- |
- |
|
- |
| 25.14(Supply Connection and External Flexible Cords, IS 302-1) |
- |
- |
|
- |
| 25.15(Supply Connection and External Flexible Cords, IS 302-1) |
- |
- |
|
- |
| 26.5(Terminals for external conductors) |
- |
- |
|
- |
| 27.5(Provision for Earthing, IS 302-1) |
- |
- |
|
- |
| 28.1(Screws and connections) |
- |
- |
|
- |
| 22.2(Construction, IS 302-1) |
- |
- |
|
- |
| 22.3(Construction, IS 302-1) |
- |
- |
|
- |
| B.22.4(Construction, IS 302-1) |
- |
- |
|
- |
| B.22.5(Construction, IS 302-1) |
- |
- |
|
- |
|
11 Sep, 2027 |
- "Domestic Electric Clothes Washing Machines
(For testing charges please refer part 2 standard in LIMS)" |
| 5 |
IS 18663 (2024) |
Note Sorting Machines- Specifications |
- |
65000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl 4.2 Safety requirements (Cl 4.1 and subclauses of IS/IEC 62368-1)(General Requirements) |
- |
500 |
|
10% discount to BIS |
| Cl 4.2 Safety requirements (Cl 4.2 and subclauses of IS/IEC 62368-1)(Energy source classifications) |
- |
500 |
|
10% discount to BIS |
| Cl 4.2 Safety requirements (Cl 4.3 and subclauses of IS/IEC 62368-1)(Protection against energy sources) |
- |
500 |
|
10% discount to BIS |
| Cl 4.2 Safety requirements (Cl 4.4 and subclauses of IS/IEC 62368-1)(Safeguards) |
- |
500 |
|
10% discount to BIS |
| Cl 4.2 Safety requirements (Cl 4.5 and subclauses of IS/IEC 62368-1)("Explosion- Requirements
") |
- |
500 |
|
10% discount to BIS |
| Cl 4.2 Safety requirements (Cl 4.6 and subclauses of IS/IEC 62368-1)(Fixing of conductors- Requirements) |
- |
1000 |
|
10% discount to BIS |
| Cl 4.2 Safety requirements (Cl 4.7 and subclauses of IS/IEC 62368-1)(Equipment for direct insertion into mains socket-outlets) |
- |
1000 |
|
10% discount to BIS |
| Cl 4.2 Safety requirements (Cl 4.8 and subclausesof IS/IEC 62368-1)(Equipment containing coin / button cell batteries) |
- |
1000 |
|
10% discount to BIS |
| Cl 4.2 Safety requirements (Cl 4.9 and subclauses of IS/IEC 62368-1)(Likelihood of fire or shock due to entry of conductive objects) |
- |
1000 |
|
10% discount to BIS |
| Cl 4.2 Safety requirements (Cl 4.10 and subclauses of IS/IEC 62368-1)(Components requirements) |
- |
1000 |
|
10% discount to BIS |
| Cl 4.2 Safety requirements (Cl 5.2 and subclauses of IS/IEC 62368-1)(Classification and limits of electrical energy sources) |
- |
1000 |
|
10% discount to BIS |
| Cl 4.2 Safety requirements (Cl 5.3 and subclauses of IS/IEC 62368-1)(Protection against electrical energy sources) |
- |
1000 |
|
10% discount to BIS |
| Cl 4.2 Safety requirements (Cl 5.4 and subclauses of IS/IEC 62368-1)(Insulation materials and requirements) |
- |
1000 |
|
10% discount to BIS |
| Cl 4.2 Safety requirements (Cl 5.5 and subclauses of IS/IEC 62368-1)(Components as safeguards) |
- |
1000 |
|
10% discount to BIS |
| Cl 4.2 Safety requirements (Cl 5.6 and subclauses of IS/IEC 62368-1)(Protective conductor) |
- |
1000 |
|
10% discount to BIS |
| Cl 4.2 Safety requirements (Cl 5.7 and subclauses of IS/IEC 62368-1)(Prospective touch voltage, touch current and protective conductor current.) |
- |
1000 |
|
10% discount to BIS |
| Cl 4.2 Safety requirements (Cl 5.8 and subclauses of IS/IEC 62368-1)(Backfeed safeguard in battery backed up supplies) |
- |
1000 |
|
10% discount to BIS |
| Cl 4.2 Safety requirements (Cl 6.1 of IS/IEC 62368-1)(Electrically-caused fire) |
- |
1000 |
|
10% discount to BIS |
| Cl 4.2 Safety requirements (Cl 6.2 and subclauses of IS/IEC 62368-1)(Classification of power sources (PS) and potential ignition sources (PIS).) |
- |
1000 |
|
10% discount to BIS |
| Cl 4.2 Safety requirements (Cl 6.3 and subclauses of IS/IEC 62368-1)(Safeguards against fire under normal operating conditions and abnormal operating conditions) |
- |
1000 |
|
10% discount to BIS |
| Cl 4.2 Safety requirements (Cl 6.4 and subclauses of IS/IEC 62368-1)(Safeguards against fire under single fault conditions) |
- |
1000 |
|
10% discount to BIS |
| Cl 4.2 Safety requirements (Cl 6.5 and subclauses of IS/IEC 62368-1)(Internal and external wiring) |
- |
1000 |
|
10% discount to BIS |
| Cl 4.2 Safety requirements (Cl 6.6 and subclauses of IS/IEC 62368-1)(Safeguards against fire due to the connection of additional equipment) |
- |
1000 |
|
10% discount to BIS |
| Cl 4.2 Safety requirements (Cl 8, 8.1 to 8.12 and subclauses of IS/IEC 62368-1)(Mechanically-caused injury) |
- |
1000 |
|
10% discount to BIS |
| Cl 4.2 Safety requirements (Cl 9, 9.1 to 9.6 and subclauses of IS/IEC 62368-1)(Thermal burn injury) |
- |
1500 |
|
10% discount to BIS |
| Cl 4.2 Safety requirements (Annex.B, B.1 to B.4 including its subclauses of IS/IEC 62368-1))(Normal operating condition tests, abnormal operating condition tests and single fault condition tests) |
- |
2000 |
|
10% discount to BIS |
| Cl 4.2 Safety requirements (Annex. D, D.1, D.2, D.3 of IS/IEC 62368-1)(Test generators) |
- |
500 |
|
10% discount to BIS |
| Cl 4.2 Safety requirements ( Annex E, E.1, E.2, E.3 of IS/IEC 62368-1)(Test conditions for equipment containing audio amplifiers) |
- |
500 |
|
10% discount to BIS |
| Cl 4.2 Safety requirements ( Annex. F, F.1 to F.5 including its subclauses of IS/IEC 62368-1)(Equipment markings, instructions, and instructional safeguards) |
- |
500 |
|
10% discount to BIS |
| Cl 4.2 Safety requirements ( Annex. G, G.1 to G.16 including its subclauses of IS/IEC 62368-1)(Components) |
- |
1000 |
|
10% discount to BIS |
| Cl 4.2 Safety requirements ( Annex. H, H1 to H3 including its subclauses of IS/IEC 62368-1)(Criteria for telephone ringing signals .) |
- |
500 |
|
10% discount to BIS |
| Cl 4.2 Safety requirements ( Annex I of IS/IEC 62368-1)(Overvoltage categories) |
- |
500 |
|
10% discount to BIS |
| Cl 4.2 Safety requirements ( Annex. J, J.1 to J.3 including its subclauses of IS/IEC 62368-1)(Insulated winding wires for use without interleaved insulation) |
- |
500 |
|
10% discount to BIS |
| Cl 4.2 Safety requirements ( Annex. L .L1 to L.9 including its subclauses of IS/IEC 62368-1)(Disconnect devices) |
- |
500 |
|
10% discount to BIS |
| Cl 4.2 Safety requirements ( Annex. M, M.1 to M.10 including its subclauses of IS/IEC 62368-1)(Equipment containing batteries and their protection circuits) |
- |
500 |
|
10% discount to BIS |
| Cl 4.2 Safety requirements ( Annex.N of IS/IEC 62368-1)(Electrochemical potentials) |
- |
500 |
|
10% discount to BIS |
| Cl 4.2 Safety requirements ( Annex.O of IS/IEC 62368-1)(Measurement of creepage distances and clearances) |
- |
1000 |
|
10% discount to BIS |
| Cl 4.2 Safety requirements ( Annex.P, P.1 to P.4 and its subclauses of IS/IEC 62368-1)(Safeguards against conductive objects) |
- |
500 |
|
10% discount to BIS |
| Cl 4.2 Safety requirements ( Annex.Q, Q.1 to Q.2 and its subclauses of IS/IEC 62368-1)(Circuits intended for interconnection with building wiring) |
- |
1000 |
|
10% discount to BIS |
| Cl 4.2 Safety requirements ( Annex.S S.1 to S.5 and its subclauses of IS/IEC 62368-1)(Tests for resistance to heat and fire) |
- |
1000 |
|
10% discount to BIS |
| Cl 4.2 Safety requirements ( Annex T, T.1 to T.11 and its subclauses of IS/IEC 62368-1)(Mechanical strength tests) |
- |
2000 |
|
10% discount to BIS |
| Cl 4.2 Safety requirements ( Annex V, V.1 to V.2 and its subclauses of IS/IEC 62368-1)(Determination of accessible parts) |
- |
500 |
|
10% discount to BIS |
| Cl 4.2 Safety requirements ( Annex X of IS/IEC 62368-1)(Alternative method for determining clearances for insulation in circuits connected to an AC mains not exceeding 420V peak (300V rms)) |
- |
500 |
|
10% discount to BIS |
| Cl 4.2 Safety requirements ( Annex Y , Y.1 to Y.6 and its subclauses of IS/IEC 62368-1)(Construction requirements for outdoor enclosure) |
- |
500 |
|
10% discount to BIS |
| Cl-4.1, 6.2 Table-1 (i)(Objects not recognized as banknotes) |
- |
500 |
|
10% discount to BIS |
| Cl-4.1, 6.2 Table-1 (ii)(Suspect/counterfeit banknotes) |
- |
500 |
|
10% discount to BIS |
| Cl-4.1, 6.2 Table-1 (iii)(Banknotes that are not clearly authenticated) |
- |
500 |
|
10% discount to BIS |
| Cl-4.1, 6.2 Table-1 (iv) (a)(Banknotes that are identified as genuine and fit;) |
- |
500 |
|
10% discount to BIS |
| Cl-4.1, 6.2 Table-1 (iv) (b)(Banknotes that are identified as genuine and unfit) |
- |
500 |
|
10% discount to BIS |
| Cl-4.1, Table-2 (i)(Piece counting) |
- |
500 |
|
10% discount to BIS |
| Cl-4.1, Table-2 (ii)(Value counting) |
- |
500 |
|
10% discount to BIS |
| Cl-4.1, Table-2 (iii)(Authenticity determination) |
- |
500 |
|
10% discount to BIS |
| Cl-4.1, Table-2 (iv)(Fitness determination) |
- |
500 |
|
10% discount to BIS |
| Cl-4.1, Table-2 (v)(Sorting of banknotes) |
- |
500 |
|
10% discount to BIS |
| Cl-4.3, Table-3 (i)(Serial number recognition) |
- |
500 |
|
10% discount to BIS |
| Cl-4.3, Table-3 (ii)(Data storage and reproduction) |
- |
500 |
|
10% discount to BIS |
| Cl-6.1, Table-4 (i)(Marking and instructions) |
- |
500 |
|
10% discount to BIS |
| Cl-6.1, Table-4 (ii)(Protection against access to live parts) |
- |
2000 |
|
10% discount to BIS |
| Cl-6.1, Table-4 (iii)(Power input and current) |
- |
3000 |
|
10% discount to BIS |
| Cl-6.1, Table-4 (iv)(Heating) |
- |
4000 |
|
10% discount to BIS |
| Cl-6.1, Table-4 (v)(Creepage clearance and solid insulation) |
- |
1000 |
|
10% discount to BIS |
| Cl-6.1, Table-4 (vi)(Humidity conditioning) |
- |
3000 |
|
10% discount to BIS |
| Cl-6.1, Table-4 (vii)(Leakage current and electric strength at operating temperature) |
- |
1500 |
|
10% discount to BIS |
| Cl-6.1, Table-4 (viii)(Provision for earthing) |
- |
1500 |
|
10% discount to BIS |
| 6.2.1(Speed Test) |
- |
500 |
|
10% discount to BIS |
| 6.2.2(Authenticity Test) |
- |
500 |
|
10% discount to BIS |
| 6.2.3(Fitness Test) |
- |
500 |
|
10% discount to BIS |
| 6.2.4(Repeatability Test) |
- |
500 |
|
10% discount to BIS |
| 6.2.5(Stress Test) |
- |
500 |
|
10% discount to BIS |
| 6.2.6(Piece Counting Test) |
- |
500 |
|
10% discount to BIS |
| 6.2.7(Values Counting Test) |
- |
500 |
|
10% discount to BIS |
| Cl 4.2 Safety requirements ( Annex. K, K.1 to K.7 including its subclauses of IS/IEC 62368-1)(Safety Interlocks) |
- |
500 |
|
10% discount to BIS |
|
11 Sep, 2027 |
- Included w.e.f.13.12.2024
exclusion
Cl 4.2 Safety requirements (Cl 4.1 and subclauses of IS/IEC 62368-1) (General Requirements)
Cl 4.2 Safety requirements (Cl 5.4 and subclauses of IS/IEC 62368-1) (Insulation materials and requirements)
Cl 4.2 Safety requirements (Cl 10, 10.1 to 10.6 and subclauses of IS/IEC 62368-1) (Radiation)
Cl 4.2 Safety requirements ( Annex. G, G.1 to G.16 including its subclauses of IS/IEC 62368-1) (Components)
Cl 4.2 Safety requirements ( Annex. G, G.1 to G.16 including its subclauses of IS/IEC 62368-1) (Components)
Cl 4.2 Safety requirements ( Annex. G, G.1 to G.16 including its subclauses of IS/IEC 62368-1) (Components)
Cl 4.2 Safety requirements ( Annex. G, G.1 to G.16 including its subclauses of IS/IEC 62368-1) (Components)
Cl 4.2 Safety requirements ( Annex. J, J.1 to J.3 including its subclauses of IS/IEC 62368-1) (Insulated winding wires for use without interleaved insulation)
Cl 4.2 Safety requirements ( Annex. M, M.1 to M.10 including its subclauses of IS/IEC 62368-1) (Equipment containing batteries and their protection circuits)
Cl 4.2 Safety requirements ( Annex. M, M.1 to M.10 including its subclauses of IS/IEC 62368-1) (Equipment containing batteries and their protection circuits)
Cl 4.2 Safety requirements ( Annex.R, R.1 to R.4 and its subclauses of IS/IEC 62368-1) (Limited short-circuit test)
Cl 4.2 Safety requirements ( Annex Y , Y.1 to Y.6 and its subclauses of IS/IEC 62368-1) (Construction requirements for outdoor enclosure)
Cl 4.2 Safety requirements ( Annex Y , Y.1 to Y.6 and its subclauses of IS/IEC 62368-1) (Construction requirements for outdoor enclosure)
Cl 4.2 Safety requirements ( Annex Y , Y.1 to Y.6 and its subclauses of IS/IEC 62368-1) (Construction requirements for outdoor enclosure)
Cl 4.2 Safety requirements ( Annex Y , Y.1 to Y.6 and its subclauses of IS/IEC 62368-1) (Construction requirements for outdoor enclosure)
Cl 4.2 Safety requirements ( Annex. K, K.1 to K.7 including its subclauses of IS/IEC 62368-1) (Safety Interlocks)
Cl 4.2 Safety requirements ( Annex. K, K.1 to K.7 including its subclauses of IS/IEC 62368-1) (Safety Interlocks) |
| 6 |
IS 16333 : Part 3 (2022) |
Mobile phone handsets: Part 3 Indian language support for mobile phone handsets - Specific requirements(Second Revision) |
Mobile Phone Handsets-Indian Language Support |
20000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 5.1(Inputting of text) |
- |
5000 |
|
10% discount to BIS |
| 5.2(Message Readability) |
- |
5000 |
|
10% discount to BIS |
| 6(Marking) |
- |
5000 |
|
10% discount to BIS |
| "Cl.6.1 "(Marking) |
- |
5000 |
|
10% discount to BIS |
| "Cl.6.2 "(BIS Certification Marking) |
- |
5000 |
|
10% discount to BIS |
| 4(Requirements) |
- |
5000 |
|
10% discount to BIS |
| 5(Tests) |
- |
5000 |
|
10% discount to BIS |
| 6(Marking) |
- |
5000 |
|
10% discount to BIS |
| 5.1(Inputting of text) |
- |
0 |
|
- |
| 5.2(Message Readability) |
- |
0 |
|
- |
| 6(Marking) |
- |
0 |
|
- |
| "Cl.6.1 "(Marking) |
- |
0 |
|
- |
| "Cl.6.2 "(BIS Certification Marking) |
- |
0 |
|
- |
| 4(Requirements) |
- |
0 |
|
- |
| 5(Tests) |
- |
0 |
|
- |
| 6(Marking) |
- |
0 |
|
- |
|
11 Sep, 2027 |
- Included w.e.f.13.12.2024 |
| 7 |
IS 302 : Part 1 (2008) |
Safety of household and similar electrical appliances: Part 1 general requirements (Sixth Revision) |
Safety of household and similar electrical appliances |
150000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 7(Marking and instructions) |
- |
5000 |
|
20% Discount to BIS |
| 8.1.1(Protection against live parts in all positions) |
- |
10000 |
|
20% Discount to BIS |
| 8.1.2(Protection against live parts in openings) |
- |
10000 |
|
20% Discount to BIS |
| 8.1.3(Protection against live parts in visible glowing heating elements) |
- |
10000 |
|
20% Discount to BIS |
| 8.1.4(Protection against live parts against protective impedance) |
- |
10000 |
|
20% Discount to BIS |
| 10.1(Power input) |
- |
10000 |
|
20% Discount to BIS |
| 10.2(Current input) |
- |
10000 |
|
20% Discount to BIS |
| 11.1(General) |
- |
10000 |
|
20% Discount to BIS |
| 11.2(General) |
- |
10000 |
|
20% Discount to BIS |
| 11.3(Heating) |
- |
10000 |
|
20% Discount to BIS |
| 13.1(General) |
- |
10000 |
|
20% Discount to BIS |
| 13.2(Leakage current at operating temperature) |
- |
10000 |
|
20% Discount to BIS |
| 13.3(Electric Strength at operating temperature) |
- |
10000 |
|
20% Discount to BIS |
| 14(Transient Over Voltages) |
- |
10000 |
|
20% Discount to BIS |
| 15.0(General) |
- |
20000 |
|
20% Discount to BIS |
| 15.1(Ingress Protection test other than IPX0 (IP test)) |
- |
20000 |
|
20% Discount to BIS |
| 15.2(Spillage Test) |
- |
20000 |
|
20% Discount to BIS |
| 15.3(Humidity Test) |
- |
20000 |
|
20% Discount to BIS |
| 16.0(General) |
- |
10000 |
|
20% Discount to BIS |
| 16.1(General) |
- |
10000 |
|
20% Discount to BIS |
| 16.2(Leakage Current (after Clause 15)) |
- |
10000 |
|
20% Discount to BIS |
| 16.3(Electric Strength (after clause 15 and 16.2)) |
- |
10000 |
|
20% Discount to BIS |
| 17(Over Load Protection of Transformers and associated circuits) |
- |
10000 |
|
20% Discount to BIS |
| 19(Abnormal Operation) |
- |
10000 |
|
20% Discount to BIS |
| 20(Stability test) |
- |
10000 |
|
20% Discount to BIS |
| 21(Mechanical Strength Test) |
- |
10000 |
|
20% Discount to BIS |
| 22(Construction verification related test) |
- |
10000 |
|
20% Discount to BIS |
| 23(General) |
- |
10000 |
|
20% Discount to BIS |
| 24(Components) |
- |
10000 |
|
20% Discount to BIS |
| 25(Supply connection and external flexible cords) |
- |
10000 |
|
20% Discount to BIS |
| 26(Terminals for external conductors) |
- |
10000 |
|
20% Discount to BIS |
| 27(Provision for earthing) |
- |
10000 |
|
20% Discount to BIS |
| 28(Screw test and connections) |
- |
10000 |
|
20% Discount to BIS |
| 29(clearance, creepage distances and solid insulation) |
- |
10000 |
|
20% Discount to BIS |
| 30.1(Ball pressure test) |
- |
10000 |
|
20% Discount to BIS |
| 30.2(Glow Wire Test) |
- |
10000 |
|
20% Discount to BIS |
| 30.2(Needle Flame Test) |
- |
10000 |
|
20% Discount to BIS |
| 31(Resistance to Rusting) |
- |
10000 |
|
20% Discount to BIS |
| 32(Radiation Toxicity and Similar Hazards) |
- |
10000 |
|
20% Discount to BIS |
| 18(Endurance Test requirements and tests) |
- |
10000 |
|
20% Discount to BIS |
| 18(Endurance) |
- |
10000 |
|
20% Discount to BIS |
| 4(General Requirement) |
- |
1000 |
|
20% Discount to BIS |
| 5(General conditions for tests) |
- |
1000 |
|
20% Discount to BIS |
| 4(General requirement) |
- |
1000 |
|
20% Discount to BIS |
| 8.1.5(Live parts of built-in appliances) |
- |
10000 |
|
20% Discount to BIS |
| 11.4(Heating appliances) |
- |
10000 |
|
20% Discount to BIS |
| 11.5(Motor-operated appliances) |
- |
10000 |
|
20% Discount to BIS |
| 11.6(Combined appliances) |
- |
10000 |
|
20% Discount to BIS |
| 11.7(Duration corresponding) |
- |
10000 |
|
20% Discount to BIS |
| 11.8(Temperature rise) |
- |
10000 |
|
20% Discount to BIS |
| 16(Leakage current and electric strength) |
- |
10000 |
|
20% Discount to BIS |
| 6(Classification- IS 302-1) |
- |
10000 |
|
20% Discount to BIS |
| 9(Starting of motor operation test requirements and tests) |
- |
10000 |
|
20% Discount to BIS |
| 17(Overload protection of transformers and associated circuits) |
- |
10000 |
|
20% Discount to BIS |
| 19.11.4.1(Electrostatic discharges) |
- |
15000 |
|
20% Discount to BIS |
| 19.11.4.2(Radiated fields) |
- |
40000 |
|
20% Discount to BIS |
| 19.11.4.3(Fast transient bursts) |
- |
15000 |
|
20% Discount to BIS |
| 19.11.4.4(Surge immunity test) |
- |
15000 |
|
20% Discount to BIS |
| 19.11.4.5(Immunity to conducted discharges) |
- |
25000 |
|
20% Discount to BIS |
| 19.11.4.6(Class 3 Voltage dips and interruptions) |
- |
15000 |
|
20% Discount to BIS |
| 19.11.4.7(Harmonics) |
- |
15000 |
|
20% Discount to BIS |
| 7(Marking and instructions) |
- |
5000 |
|
20% Discount to BIS |
| 8.1.1(Protection against live parts in all positions) |
- |
5000 |
|
20% Discount to BIS |
| 8.1.2(Protection against live parts in openings) |
- |
5000 |
|
20% Discount to BIS |
| 8.1.3(Protection against live parts in visible glowing heating elements) |
- |
2000 |
|
20% Discount to BIS |
| 8.1.4(Protection against live parts against protective impedance) |
- |
2000 |
|
20% Discount to BIS |
| 10.1(Power input) |
- |
10000 |
|
20% Discount to BIS |
| 10.2(Current input) |
- |
10000 |
|
20% Discount to BIS |
| 11.1(General) |
- |
10000 |
|
20% Discount to BIS |
| 11.2(General) |
- |
5000 |
|
20% Discount to BIS |
| 11.3(Heating) |
- |
5000 |
|
20% Discount to BIS |
| 13.1(General) |
- |
5000 |
|
20% Discount to BIS |
| 13.2(Leakage current at operating temperature) |
- |
10000 |
|
20% Discount to BIS |
| 13.3(Electric Strength at operating temperature) |
- |
10000 |
|
20% Discount to BIS |
| 14(Transient Over Voltages) |
- |
10000 |
|
20% Discount to BIS |
| 15.0(General) |
- |
5000 |
|
20% Discount to BIS |
| 15.1(Ingress Protection test other than IPX0 (IP test)) |
- |
5000 |
|
20% Discount to BIS |
| 15.2(Spillage Test) |
- |
1000 |
|
20% Discount to BIS |
| 15.3(Humidity Test) |
- |
20000 |
|
20% Discount to BIS |
| 16.0(General) |
- |
10000 |
|
20% Discount to BIS |
| 16.1(General) |
- |
10000 |
|
20% Discount to BIS |
| 16.2(Leakage Current (after Clause 15)) |
- |
10000 |
|
20% Discount to BIS |
| 16.3(Electric Strength (after clause 15 and 16.2)) |
- |
10000 |
|
20% Discount to BIS |
| 17(Over Load Protection of Transformers and associated circuits) |
- |
10000 |
|
20% Discount to BIS |
| 19(Abnormal Operation) |
- |
15000 |
|
20% Discount to BIS |
| 20(Stability test) |
- |
5000 |
|
20% Discount to BIS |
| 21(Mechanical Strength Test) |
- |
5000 |
|
20% Discount to BIS |
| 22(Construction verification related test) |
- |
5000 |
|
20% Discount to BIS |
| 23(General) |
- |
5000 |
|
20% Discount to BIS |
| 24(Components) |
- |
5000 |
|
20% Discount to BIS |
| 25(Supply connection and external flexible cords) |
- |
5000 |
|
20% Discount to BIS |
| 26(Terminals for external conductors) |
- |
1000 |
|
20% Discount to BIS |
| 27(Provision for earthing) |
- |
10000 |
|
20% Discount to BIS |
| 28(Screw test and connections) |
- |
1000 |
|
20% Discount to BIS |
| 29(clearance, creepage distances and solid insulation) |
- |
5000 |
|
20% Discount to BIS |
| 30.1(Ball pressure test) |
- |
5000 |
|
20% Discount to BIS |
| 30.2(Glow Wire Test) |
- |
10000 |
|
20% Discount to BIS |
| 30.2(Needle Flame Test) |
- |
10000 |
|
20% Discount to BIS |
| 31(Resistance to Rusting) |
- |
10000 |
|
20% Discount to BIS |
| 32(Radiation Toxicity and Similar Hazards) |
- |
0 |
|
20% Discount to BIS |
| 18(Endurance Test requirements and tests) |
- |
0 |
|
- |
| 18(Endurance) |
- |
0 |
|
- |
| 4(General Requirement) |
- |
0 |
|
- |
| 5(General conditions for tests) |
- |
0 |
|
- |
| 4(General requirement) |
- |
0 |
|
- |
| 8.1.5(Live parts of built-in appliances) |
- |
1000 |
|
20% Discount to BIS |
| 11.4(Heating appliances) |
- |
10000 |
|
20% Discount to BIS |
| 11.5(Motor-operated appliances) |
- |
5000 |
|
20% Discount to BIS |
| 11.6(Combined appliances) |
- |
5000 |
|
20% Discount to BIS |
| 11.7(Duration corresponding) |
- |
5000 |
|
20% Discount to BIS |
| 11.8(Temperature rise) |
- |
5000 |
|
20% Discount to BIS |
| 16(Leakage current and electric strength) |
- |
10000 |
|
20% Discount to BIS |
| 6(Classification- IS 302-1) |
- |
1000 |
|
20% Discount to BIS |
| 9(Starting of motor operation test requirements and tests) |
- |
0 |
|
20% Discount to BIS |
| 17(Overload protection of transformers and associated circuits) |
- |
5000 |
|
20% Discount to BIS |
| 19.11.4.1(Electrostatic discharges) |
- |
15000 |
|
20% Discount to BIS |
| 19.11.4.2(Radiated fields) |
- |
40000 |
|
20% Discount to BIS |
| 19.11.4.3(Fast transient bursts) |
- |
15000 |
|
20% Discount to BIS |
| 19.11.4.4(Surge immunity test) |
- |
15000 |
|
20% Discount to BIS |
| 19.11.4.5(Immunity to conducted discharges) |
- |
15000 |
|
20% Discount to BIS |
| 19.11.4.6(Class 3 Voltage dips and interruptions) |
- |
15000 |
|
20% Discount to BIS |
| 19.11.4.7(Harmonics) |
- |
15000 |
|
20% Discount to BIS |
|
11 Sep, 2027 |
- Included w.e.f 12.03.2025
Exclusion: Cl.8.1.4 - Measurements of electric charge, Energy discharge measurement in mJ, Cl.12 - Charging of metal-ion batteries, Cl.19.11.4.7 - Mains signal test (IEC 61000-4-13), Cl.22.16 - Automatic cord reel test apparatus, Cl.22.32 - Resistant to ageing test (Oxygen bomb with pressure apparatus), Cl.22.32 - Resistant to ageing test (Methylated spirits), Cl.22.48 (Electric Appliances connected to the water mains – Avoidance of back siphonage and failure of hose-sets), Cl 23.3- Flexing test, Cl.30.2.1, 30.2.4 - Horizontal and vertical burning test, Cl.32.2 - Optical radiation hazard Annex B - Battery-operated appliances, separable batteries and detachable batteries for battery-operated appliances (IEC 60335- 1:2020), Annex F - Endurance test for Capacitors, Annex H – Switches, Annex J - Coated printed circuit boards test, Annex R - Software evaluation, Annex T - UV-C radiation effect on non-metallic materials, Annex U- Evaluation for remote communication through public networks
"(1)Cooking ranges, hobs, ovens and similar appliances, (2)Commercial Dispensing Appliances and Vending Machines, (3) spin extractors
(For testing charges please refer relevant Part 2 standard in LIMS)" |
| 8 |
IS/IEC 62368 : Part 1 (2018) |
Audio / Video, Information and Communication Technology Equipment Part 1 Safety Requirements ( First Revision ) |
Audio/video, information and communication technology |
212000 View breakup
Rs.2,12,000/- (10% Discount)
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl. 4, 4.1, 4.1.1, 4.1.2, 4.1.3, 4.1.4, 4.1.5, 4.1.6, 4.1.7, 4.1.8, 4.1.9,4.1.10, 4.1.11,4.1.12, 4.1.13, 4.1.14,4.1.15(General Requirements) |
- |
3000 |
|
10% discount to BIS |
| Cl. 4.2, 4.2.1, 4.2.2, 4.2.3, 4.2.4(Energy source classifications) |
- |
3000 |
|
10% discount to BIS |
| Cl. No. 4.3 ,4.4,4.5, 4.6,4.7,4.8,4.9,4.10 with all sub clauses(Protection against energy sources) |
- |
3000 |
|
- |
| Cl. No. 5,5.1,5.2,5.3,5.4,5.5,5.6,5.7,5.8 with all sub clauses(Electrically-caused injury) |
- |
40000 |
|
10% discount to BIS |
| Cl No. 6,6.1,6.2,6.3,6.4,6.5,6.6 with all sub clause(Electrically-caused fire) |
- |
25000 |
|
10% discount to BIS |
| Cl. 7, 7.1, 7.2, 7.3, 7.4, 7.5, 7.6(Injury caused by hazardous substances) |
- |
5000 |
|
10% discount to BIS |
| Cl. 9, 9.1, 9.2, 9.2.1,9.2.2, 9.2.3, 9.3, 9.3.1, 9.3.2, 9.4, 9.5, 9.5.1, 9.5.2, 9.6, 9.6.1, 9.6.2, 9.6.3(Thermal burn injury) |
- |
25000 |
|
10% discount to BIS |
| Cl. 8,8.1,8.2,8.3,8.4,8.5,8.6,8.7,8.8,8.9,8.10,8.11,8.12 with all sub clause(Mechanically-caused injury) |
- |
8000 |
|
10% discount to BIS |
| Annex. B, B.1, B.1.1, B.1.2, B.1.3, B.1.4, B.1.5,B.2,B.2.1, B.2.2, B.2.3, B.2.4, B.2.5, B.2.6, B.2.6.1, B.2.6.2, B.2.6.3, B.2.7, B.3, B.3.1, B.3.2, B.3.3, B.3.4, B.3.5, B.3.6, B.3.7, B.3.8, B.4, B.4.1, B.4.2, B.4.3, B.4.3.1, B.4.3.2,B.4.4, B.4.4.1, B.4.4.(Normal operating condition tests, abnormal operating condition tests and single fault condition tests) |
- |
20000 |
|
10% discount to BIS |
| Annex. D, D.1, D.2, D.3(Test Generators) |
- |
2000 |
|
10% discount to BIS |
| Annex E, E.1, E.2, E.3(Test conditions) |
- |
5000 |
|
10% discount to BIS |
| Annex. F, F.1, F.2, F2.1, F.2.2,F2.3,F.3, F.3.1, F.3.2, F.3.2.1,F.3.2.2, F.3.3,F.3.3.1, F.3.3.2,F.3.3.3, F.3.3.4, F.3.3.5, F.3.3.6,F.3.3.7, F.3.3.8, F.3.4, F.3.5, F.3.5.1,F.3.5.2, F.3.5.3, F.3.5.4, F.3.5.5,F.3.5.6, F.3.5.7,F.3.6, F.3.6.1, F.3.6.1.1, F.3.6(Equipment markings, instructions, and instructional safeguards) |
- |
3000 |
|
10% discount to BIS |
| Annex. G, G.1, G.1.1, G.1.2, G.1.3, G.2, G.2.1, G.2.2, G.2.3, G.2.4, G.3, G.3.1, G.3.1.1, G.3.1.2, G.3.2, G.3.2.1,G.3.2.2, G.3.3,G.3.4, G.3.5, G.3.5.1, G.3.5.2, G.4, G.4.1, G.4.2, G.4.3, G.5, G.5.1, G.5.1.1, G.5.1.2,G.5.1.3,G.5.2,G.5.2.1, G.5.2.2, G.5.2.3(Components) |
- |
15000 |
|
10% discount to BIS |
| Annex I(Overvoltage categories) |
- |
1000 |
|
10% discount to BIS |
| Annex. J, J.1, J.2, J.2.1, J.2.2, J.2.2.1, J.2.2.1.1, J.2.2.1.2, J.2.2.1.3, J.2.2.2, J.2.3, J.2.4, J.2.5, J.3, J.3.1, J.3.2, J.3.3(Insulated winding wires for use without interleaved insulation) |
- |
5000 |
|
10% discount to BIS |
| Annex. K, K.1, K.1.1, K.1.2, K.2, K.3, K.4, K.5, K.5.1, K.5.2, K.6, K.6.1, K.6.2, K.7, K.7.1, K.7.2, K.7.3, K.7.4(Safety Interlocks) |
- |
4000 |
|
10% discount to BIS |
| Annex. L, L.1, L.2, L.3, L.4, L.5, L.6, L.7, L.8, L.9,(Disconnect devices) |
- |
2000 |
|
10% discount to BIS |
| Annex. N(Electrochemical potentials) |
- |
0 |
|
- |
| Annex. O(Measurement of creepage distances and clearances) |
- |
5000 |
|
10% discount to BIS |
| Annex. P, P.1, P.2, P.2.1, P.2.2, P.2.3, P.2.3.1, P.2.3.2, P.3, P.3.1, P.3.2, P.3.3, P.3.4, P.4, P.4.1, P.4.2(Safeguards against conductive objects) |
- |
8000 |
|
10% discount to BIS |
| Annex. Q, Q.1, Q.1.1, Q.1.2, Q.2(Circuits intended for interconnection with building wiring) |
- |
6000 |
|
10% discount to BIS |
| Annex. S, S.1, S.2, S.3, S.3.1, S.3.2, S.4, S.5(Tests for resistance to heat and fire) |
- |
8000 |
|
10% discount to BIS |
| Annex. T, T.1, T.2, T.3, T.4, T.5, T.6, T.7, T.8, T.9, T.10, T.11(Mechanical strength tests) |
- |
6000 |
|
10% discount to BIS |
| Annex. V, V.1, V.1.1, V.1.2, V.1.3, V.1.4, V.1.5, V.1.6, V.2(Determination of accessible parts) |
- |
5000 |
|
10% discount to BIS |
| Annex. X(Alternative method for determining clearances for insulation in circuits connected to an AC mains not exceeding 420V peak (300V rms)) |
- |
5000 |
|
10% discount to BIS |
|
11 Sep, 2027 |
- Exclusion: Cl.4.1.8 (Liquids and liquid filled components (LFC)), Cl. 5.6.4.1 & Cl. 5.4.12.3 (Compatibility of an insulating liquid), Cl.7.2 (Reduction of exposure to hazardous Substances) Cl.10 (Radiation), Annex G.5.3.4 (Test for FIW), Annex G.7 (Mains supply cords), Annex G.9 (IC current limiters), Annex G.15 (Hydrostatic pressure), Annex J.3 (Testing during manufacturing), Annex M.7, M.8.2 (Risk of explosion from lead acid and NiCd batteries), Annex R (Limited Short-Circuit Test), Annex Y (Constructions requirements for outdoor enclosures), Annex C (UV Radiation) |
| 9 |
IS 15885 : Part 2 : Sec 13 (2012) |
Safety of lamp controlgear: Part 2 particular requirements: Sec 13 d.c. or a.c. supplied electronic controlgear for led modules |
d.c. or a.c. supplied electronic controlgear |
75000 View breakup
Rs.75,000/- (10% Discount)
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 7(Marking) |
- |
2500 |
|
10% discount to BIS |
| 8(Protection against accidental contact with live parts) |
- |
3000 |
|
10% discount to BIS |
| 9(Terminals) |
- |
3500 |
|
10% discount to BIS |
| 10(PROVISION FOR EARTHING) |
- |
5000 |
|
10% discount to BIS |
| 11(MOISTURE RESISTANCE) |
- |
5500 |
|
10% discount to BIS |
| 12(Electric Strength) |
- |
6500 |
|
10% discount to BIS |
| 13(Thermal endurance test for winding of ballasts) |
- |
0 |
|
10% discount to BIS |
| 14(Fault conditions) |
- |
7500 |
|
10% discount to BIS |
| 15(Transformer heating) |
- |
9500 |
|
10% discount to BIS |
| 16(Construction) |
- |
7500 |
|
10% discount to BIS |
| 17(Creepage distance and clearances) |
- |
6500 |
|
10% discount to BIS |
| 18(Screws, current carrying parts and connections) |
- |
7000 |
|
10% discount to BIS |
| 19(Resistance to heat, fire and tracking) |
- |
5500 |
|
10% discount to BIS |
| 20(Resistance to corrosion) |
- |
5500 |
|
10% discount to BIS |
| 16(Enclosures) |
- |
0 |
|
- |
| 16(Bridging resistor in primary circuit) |
- |
0 |
|
- |
| 16(Capacitor and RC units) |
- |
0 |
|
- |
| 16(RF suppression (X-Y capacitors)) |
- |
0 |
|
- |
| 16(Inductor) |
- |
0 |
|
- |
| 16(MOV/VDR) |
- |
0 |
|
- |
| 16(SMPS/Mains Transformer) |
- |
0 |
|
- |
| 16(PCB material) |
- |
0 |
|
- |
| 19(Metal base PCB for LED) |
- |
0 |
|
- |
| 19(Transparent cover) |
- |
0 |
|
- |
| 19(Bobbin) |
- |
0 |
|
- |
| 16(Insulated tape) |
- |
0 |
|
- |
| 16(Heat shrinkage sleeve) |
- |
0 |
|
- |
| 19(Terminals) |
- |
0 |
|
- |
| 16(Connector) |
- |
0 |
|
- |
| 16(Fuse) |
- |
0 |
|
- |
| 16(Internal wire) |
- |
0 |
|
- |
| 16(LED) |
- |
0 |
|
- |
| 16(Opto-coupler) |
- |
0 |
|
- |
| 16(Opto-coupler) |
- |
0 |
|
- |
| 16(EMI/EMC filter) |
- |
0 |
|
- |
| 16(Winding wire) |
- |
0 |
|
- |
| 16(Thin sheet materials) |
- |
0 |
|
- |
| 7(Marking) |
- |
2500 |
|
10% discount to BIS |
| 8("PROTECTION AGAINST ACCIDENTAL
CONTACT WITH LIVE PARTS") |
- |
3500 |
|
10% discount to BIS |
| 9(TERMINALS) |
- |
3500 |
|
10% discount to BIS |
| 10(PROVISIONS FOR PROTECTIVE EARTHING) |
- |
5000 |
|
10% discount to BIS |
| 11(MOISTURE RESISTANCE AND INSULATION) |
- |
5500 |
|
10% discount to BIS |
| 12(ELECTRIC STRENGTH) |
- |
6500 |
|
10% discount to BIS |
| 14(FAULT CONDITIONS) |
- |
7500 |
|
10% discount to BIS |
| 15(TRANSFORMER HEATING) |
- |
9500 |
|
10% discount to BIS |
| 16(CONSTRUCTION) |
- |
7500 |
|
10% discount to BIS |
| 17(CREEPAGE DISTANCES AND CLEARANCES) |
- |
6500 |
|
10% discount to BIS |
| 18("SCREWS, CURRENT-CARRYING PARTS
AND CONNECTIONS") |
- |
7000 |
|
10% discount to BIS |
| 19(RESISTANCE TO HEAT, FIRE AND TRACKING) |
- |
5500 |
|
10% discount to BIS |
| 20(RESISTANCE TO CORROSION) |
- |
5500 |
|
10% discount to BIS |
| 4(GENERAL REQUIREMENTS) |
- |
0 |
|
- |
| 5(GENERAL NOTES ON TESTS) |
- |
0 |
|
- |
| 6(CLASSIFICATION) |
- |
0 |
|
- |
|
11 Sep, 2027 |
- - |
| 10 |
IS 16102 : Part 1 (2012) |
Self - Ballasted led lamps for general lighting services: Part 1 safety requirements |
Self - Ballasted led lamps for general lighting service |
75000 View breakup
Rs.75,000/- (10% Discount)
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 5(Marking) |
- |
3000 |
|
10% discount to BIS |
| 6(Interchangeability) |
- |
5000 |
|
10% discount to BIS |
| 7(Protection against accidental contact with live parts) |
- |
7000 |
|
10% discount to BIS |
| 8(Insulation Resistance and Electric Strength) |
- |
9000 |
|
10% discount to BIS |
| 9(MECHANICAL STRENGTH) |
- |
7000 |
|
10% discount to BIS |
| 10(cap temperature) |
- |
7500 |
|
10% discount to BIS |
| 11(Resistance to Heat) |
- |
9000 |
|
10% discount to BIS |
| 12(Resistance to Flame and Ignition) |
- |
8500 |
|
10% discount to BIS |
| 13(Fault conditions) |
- |
11000 |
|
10% discount to BIS |
| 14(Creepage distance and clearances) |
- |
8000 |
|
10% discount to BIS |
| 4(General requirement and General test requirements) |
- |
0 |
|
10% discount to BIS |
| 15(Selection of lamps for tests (Sampling)) |
- |
0 |
|
- |
| 16(Condition of compliance) |
- |
0 |
|
- |
| 17(Tests) |
- |
0 |
|
- |
| Annex A(Ovreview of systems composed of LED modules and control gear) |
- |
0 |
|
- |
| Annex B(Lamps with operating position limitations) |
- |
0 |
|
- |
| 5(Marking) |
- |
3000 |
|
10% discount to BIS |
| 6(Interchangeability) |
- |
5000 |
|
10% discount to BIS |
| 7(Protection against accidental contact with live parts) |
- |
7000 |
|
10% discount to BIS |
| 8(Strength after humidity treatment) |
- |
9000 |
|
10% discount to BIS |
| 9(Mechanical strength) |
- |
7000 |
|
10% discount to BIS |
| 10(Cap temperature rise) |
- |
7500 |
|
10% discount to BIS |
| 11(Resistance to heat) |
- |
9000 |
|
10% discount to BIS |
| 12(Resistance to flame and ignition) |
- |
8500 |
|
10% discount to BIS |
| 13(Fault conditions) |
- |
11000 |
|
10% discount to BIS |
| 14(Creepage distances and clearances) |
- |
8000 |
|
10% discount to BIS |
| 4(GENERAL REQUIREMENT AND GENERAL TEST REQUIREMENTS) |
- |
0 |
|
- |
|
11 Sep, 2027 |
- - |
| 11 |
IS 10322 : Part 5 : Sec 5 (2013) |
Luminaires: Part 5 particular requirements: Sec 5 floodlights (First Revision) |
Floodlights |
80000 View breakup
Rs.80,000/- (10% Discount)
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4(General Test Requireements) |
- |
2500 |
|
10% discount to BIS |
| 5(Classification of Luminaires') |
- |
2500 |
|
10% discount to BIS |
| 6.0(Marking) |
- |
3000 |
|
10% discount to BIS |
| 7.0(Construction) |
- |
4000 |
|
10% discount to BIS |
| 8.0(Creepage Distance and Clearances) |
- |
5000 |
|
10% discount to BIS |
| 9.0(Provision for earthing) |
- |
7000 |
|
10% discount to BIS |
| 10.0(Terminals) |
- |
7000 |
|
10% discount to BIS |
| 12.0(Protection against electric shock) |
- |
9000 |
|
10% discount to BIS |
| 13.0(Endurance Tests and Thermal Tests) |
- |
10000 |
|
10% discount to BIS |
| 14.0(Resistance to Dust & Moisture) |
- |
7000 |
|
10% discount to BIS |
| 15.0(Insulation Resistance and Electric Strength) |
- |
8000 |
|
10% discount to BIS |
| 16.0(Resistance to Heat , fire and tracking) |
- |
7000 |
|
10% discount to BIS |
| 11.0(External & Internal Wiring) |
- |
8000 |
|
10% discount to BIS |
|
11 Sep, 2027 |
- Exclusion: Cl.4.24 (UV Radiation), Cl.4.11.6 (Electromechanical Contact), Cl.17 (Photometric test) |
| 12 |
IS 10322 : PART 5 : SEC 3 (2012) |
Luminaires: Part 5 particular requirements: Sec 3 luminaires for road and street lighting (First Revision) |
luminaires for road and street lighting |
80000 View breakup
Rs.80,000/- (10% Discount)
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4(General Test Requireements) |
- |
2500 |
|
10% discount to BIS |
| 5(Classification of Luminaires') |
- |
2500 |
|
10% discount to BIS |
| 6.0(Marking) |
- |
3000 |
|
10% discount to BIS |
| 7.0(Construction) |
- |
4000 |
|
10% discount to BIS |
| 8.0(Creepage Distance and Clearances) |
- |
5000 |
|
10% discount to BIS |
| 9.0(Provision for earthing) |
- |
7000 |
|
10% discount to BIS |
| 10.0(Terminals) |
- |
7000 |
|
10% discount to BIS |
| 11.0(External & Internal Wiring) |
- |
8000 |
|
10% discount to BIS |
| 12.0(Protection against electric shock) |
- |
9000 |
|
10% discount to BIS |
| 13.0(Endurance Tests and Thermal Tests) |
- |
10000 |
|
10% discount to BIS |
| 14.0(Resistance to Dust & Moisture) |
- |
7000 |
|
10% discount to BIS |
| 15.0(Insulation Resistance and Electric Strength) |
- |
8000 |
|
10% discount to BIS |
| 16.0(Resistance to Heat , fire and tracking) |
- |
7000 |
|
10% discount to BIS |
|
11 Sep, 2027 |
- Exclusion: Cl.4.24 (UV Radiation), Cl.4.11.6 (Electromechanical Contact), Cl.17 (Photometric test) |
| 13 |
IS 13252 : Part 1 (2010) |
Information technology equipment - Safety: Part 1 general requirements (Second Revision) |
Information technology equipment |
160000 View breakup
Rs.1,60,000/- (10% Discount)
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 1.5(Components) |
- |
5000 |
|
10% discount to BIS |
| 1.6(Power interface .) |
- |
2000 |
|
10% discount to BIS |
| 1.7(Markings and instructions) |
- |
3000 |
|
10% discount to BIS |
| 2.1(Protection from electric shock and energy hazards) |
- |
16500 |
|
10% discount to BIS |
| 2.2(SELV circuits) |
- |
4500 |
|
10% discount to BIS |
| 2.3(TNV circuits) |
- |
14000 |
|
10% discount to BIS |
| 2.4(Limited current circuits) |
- |
2000 |
|
10% discount to BIS |
| 2.5(Limited power sources .) |
- |
2500 |
|
10% discount to BIS |
| 2.6(Provisions for earthing and bonding) |
- |
2500 |
|
10% discount to BIS |
| 2.7(Overcurrent and earth fault protection in primary circuits) |
- |
2000 |
|
10% discount to BIS |
| 2.8(Safety interlocks) |
- |
2500 |
|
10% discount to BIS |
| 2.9(Electrical insulation) |
- |
2000 |
|
10% discount to BIS |
| 2.10(Clearances, creepage distances and distances through insulation) |
- |
8500 |
|
10% discount to BIS |
| 2.10.9(Thermal Cycling) |
- |
0 |
|
- |
| 2.10.10(Test for Pollution Degree 1 environment and for insulating compound) |
- |
0 |
|
- |
| 2.10.11(Tests for semiconductor devices and for cemented joints) |
- |
0 |
|
- |
| 2.10.12(Enclosed and sealed parts) |
- |
0 |
|
- |
| 3.1(General) |
- |
2000 |
|
10% discount to BIS |
| 3.2(Connection to a mains supply) |
- |
4000 |
|
10% discount to BIS |
| 3.3(Wiring terminals for connection of external conductors) |
- |
1500 |
|
10% discount to BIS |
| 3.5(Interconnection of equipment) |
- |
1500 |
|
10% discount to BIS |
| 4.1(Stability) |
- |
2000 |
|
10% discount to BIS |
| 4.2(Mechanical strength) |
- |
14000 |
|
10% discount to BIS |
| 4.3(Design and construction) |
- |
8000 |
|
10% discount to BIS |
| 4.4(Protection against hazardous moving parts) |
- |
2000 |
|
10% discount to BIS |
| 4.5(Thermal requirements) |
- |
3000 |
|
10% discount to BIS |
| 4.6(Openings in enclosures) |
- |
2000 |
|
10% discount to BIS |
| 4.7(Resistance to fire) |
- |
2000 |
|
10% discount to BIS |
| 5.1(Touch current and protective conductor curren) |
- |
2000 |
|
10% discount to BIS |
| 5.2(Electric strength) |
- |
4000 |
|
10% discount to BIS |
| 5.3(Abnormal operating and fault conditions) |
- |
3000 |
|
10% discount to BIS |
| 6.1(Protection of telecommunication network service persons, and users of other equipment connected to the network, from hazards in the equipment) |
- |
3000 |
|
10% discount to BIS |
| 6.2(Protection of equipment users from overvoltages on networks telecommunication) |
- |
3000 |
|
10% discount to BIS |
| 6.3(Protection of the telecommunication wiring system from overheating) |
- |
3000 |
|
10% discount to BIS |
| 7.4(Insulation between primary circuits and cable distribution systems) |
- |
3000 |
|
10% discount to BIS |
| Annex A3(Hot flaming oil test) |
- |
5000 |
|
10% discount to BIS |
| Annex B(Motor tests under abnormal conditions) |
- |
4000 |
|
10% discount to BIS |
| Annex C(Transformers) |
- |
4000 |
|
10% discount to BIS |
| Annex DD(Requirements for the mounting means of a rack mounted equipment) |
- |
2000 |
|
10% discount to BIS |
| Annex CC(Evaluation of integrated circuit (IC) current limiters) |
- |
2000 |
|
10% discount to BIS |
| Annex EE(Household and home/ office document/ media shredders) |
- |
2000 |
|
10% discount to BIS |
| 4.6.2(Bottoms of fire enclosures) |
- |
0 |
|
10% discount to BIS |
| 3.4(Disconnection from the mains supply) |
- |
1500 |
|
10% discount to BIS |
| 7.1(General) |
- |
500 |
|
10% discount to BIS |
| 7.2(Protection of cable distribution system service persons, and users of other equipment connected to the system, from hazardous voltages in the equipment) |
- |
3000 |
|
10% discount to BIS |
| 7.3(Protection of equipment users from overvoltages on the cable distribution system) |
- |
4000 |
|
10% discount to BIS |
| 2.10.4.2(Material Group and Comparative Tracking Index) |
- |
0 |
|
- |
| 2.10.5.3(Insulating Compound as Solid Insulation) |
- |
0 |
|
- |
| 2.10.5.6(Thin sheet materials) |
- |
0 |
|
- |
| 2.10.5.11(SMPS Transformer and Inductor) |
- |
0 |
|
- |
| 2.10.5.12(Wires in wound components) |
- |
0 |
|
- |
| 2.10.5.13(Winding wire) |
- |
0 |
|
- |
| 2.10.5.14(Additional insulation in wound components) |
- |
0 |
|
- |
| 2.10.6(PCB material) |
- |
0 |
|
- |
| 2.10.8.2(Thermal conditioning (thermal ageing)) |
- |
0 |
|
- |
| 2.10.8.4(Abrasion resistance test) |
- |
0 |
|
- |
| 3.1.4(Internal wire) |
- |
0 |
|
- |
| 3.2.4(Appliance inlet /connector) |
- |
0 |
|
- |
| 3.2.4(Appliance inlet /connector) |
- |
0 |
|
- |
| 3.2.5(Non re-wirable plug with PVC sheathed cable) |
- |
0 |
|
- |
| 4.3.8(Batteries) |
- |
0 |
|
- |
| 4.3.10(Dust, powders, liquids and gases) |
- |
0 |
|
- |
| 4.3.11(Containers for liquids or gases) |
- |
0 |
|
- |
| 1.5(Components) |
- |
0 |
|
- |
|
11 Sep, 2027 |
- Exclusion: Cl.2.10.5.4 (Semiconductor devices), Cl. 2.8.2 (Interlock switches) Cl.2.8.5 (Moving parts), Cl.2.8.7 (Switches & Relays), Cl.4.2.8 (Cathode Ray Tube), Cl.4.2.9 (High pressure lamps), Cl.4.3.12 (Flammable liquids), Cl.4.3.13 (Radiation), Annex K (Thermal Controls), Annex Q (Voltage dependent Resistors (VDRs)), Annex U (Insulated winding wires) |
| 14 |
IS 616 (2017) |
Audio, video and similar electronic apparatus - Safety requirements (Fifth Revision) |
Audio, video and similar electronic apparatus |
121000 View breakup
Rs.1,21,000/- (10% Discount)
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 5(Marking and instructions) |
- |
3500 |
|
10% discount to BIS |
| 7(Heating under normal operating conditions) |
- |
9500 |
|
10% discount to BIS |
| 8(Constructional requirements with regard to the protection against electric shock) |
- |
6500 |
|
10% discount to BIS |
| 9(Electric shock hazard under normal operating conditions) |
- |
7000 |
|
10% discount to BIS |
| 10(Insulation requirements) |
- |
8000 |
|
10% discount to BIS |
| 11(Fault conditions) |
- |
9000 |
|
10% discount to BIS |
| 12(Mechanical strength) |
- |
9000 |
|
10% discount to BIS |
| 13(CLEARANCES and CREEPAGE DISTANCES) |
- |
7000 |
|
10% discount to BIS |
| 14(Components) |
- |
8000 |
|
10% discount to BIS |
| 15(TERMINALS) |
- |
8000 |
|
10% discount to BIS |
| 17(Electrical connections and mechanical fixings) |
- |
6500 |
|
10% discount to BIS |
| 19(Stability and mechanical hazards) |
- |
6000 |
|
10% discount to BIS |
| 20(Resistance to fire) |
- |
4000 |
|
10% discount to BIS |
| Annex-A(Additional requirements for apparatus with protection against splashing water) |
- |
5000 |
|
10% discount to BIS |
| 16(External flexible cords) |
- |
6000 |
|
10% discount to BIS |
| 20.2.4(Printed Boards) |
- |
0 |
|
- |
| 3(General requirements) |
- |
4000 |
|
-- |
| 4(General test conditions) |
- |
4000 |
|
- |
| Annex-B(Apparatus to be connected to the TELECOMMUNICATION NETWORKS) |
- |
6000 |
|
- |
| Annex-L(Additional requirements for electronic flash apparatus for photographic purposes) |
- |
4000 |
|
- |
| Cl.5.1 of Cl.5(General requirements) |
- |
0 |
|
- |
| Cl.5.1-i) of Cl.5(Comprehensible and easily discernible) |
- |
0 |
|
- |
| Cl.5.1-ii) of Cl.5(Permanent durability against water and petroleum spirit) |
- |
0 |
|
- |
| Cl.5.2 of Cl.5(Identification and supply ratings) |
- |
0 |
|
- |
| Cl.5.2 a) of Cl.5(Identification, maker) |
- |
0 |
|
- |
| Cl.5.2 b) of Cl.5(Model number or type reference) |
- |
0 |
|
- |
| Cl.5.2 d) of Cl.5(Nature of supply) |
- |
0 |
|
- |
| Cl.5.2 e) of Cl.5(Rated supply voltage) |
- |
0 |
|
- |
| Cl.5.2 f) of Cl.5(Mains frequency if safety dependant) |
- |
0 |
|
- |
| Cl.5.2 g) of Cl.5(Rated current or power consumption for apparatus supplied by supply apparatus for general use, on apparatus or in instruction manual: Measured current or power consumption: Deviation % (max 10%):) |
- |
0 |
|
- |
| Cl.5.2 h) of Cl.5(Rated current or power consumption for apparatus intended for connection to an a.c. mains supply:Measured current or power consumption for Television set: Deviation % (max 10%):) |
- |
0 |
|
- |
| Cl.5.2 h)-ii) of Cl.5(Graphical symbols placed on the apparatus, whether required by this standard or not, shall be in accordance with IEC 60417 or ISO 3864-2 or ISO 7000, if available. In the absence of suitable symbols, the manufacturer may design specific graphical symbols.) |
- |
0 |
|
- |
| Cl.5.2 h)-iii) of Cl.5(Care shall be taken so that additional markings and instructions not required by this standard do not contradict the markings and instructions required by this standard . Symbols placed on the Equipment shall be explained in the user manual.) |
- |
0 |
|
- |
| Cl.5.3 of Cl.5(Terminals) |
- |
0 |
|
- |
| Cl.5.3a) of Cl.5(Earth terminal) |
- |
0 |
|
- |
| Cl.5.3b) of Cl.5(Hazardous live terminals) |
- |
0 |
|
- |
| Cl.5.3c) of Cl.5(Markings on supply output terminals) |
- |
0 |
|
- |
| Cl.5.4 of Cl.5(Caution marking) |
- |
0 |
|
- |
| Cl.5.4a) of Cl.5(Use of triangle with exclamation mark) |
- |
0 |
|
- |
| Cl.5.4b) of Cl.5(Marking on loudspeaker grille, IEC 60417-5036) |
- |
0 |
|
- |
| Cl.5.4c) of Cl.5(User-replaceable coin / button cell battery marking) |
- |
0 |
|
- |
| Cl.5.5 of Cl.5(Instructions) |
- |
0 |
|
- |
| Cl.5.5.1 of Cl.5.5(Safety relevant information) |
- |
0 |
|
- |
| Cl.5.5.2 a) of Cl.5.5(Mains powered equipment not exposed to dripping or splashing. Warning concerning objects filled with liquid, etc.) |
- |
0 |
|
- |
| Cl.5.5.2 b) of Cl.5.5(Hazardous live terminals, instructions for wiring) |
- |
0 |
|
- |
| Cl.5.5.2 c) of Cl.5.5(Instructions for replacing lithium battery) |
- |
0 |
|
- |
| Cl.5.5.2 d) of Cl.5.5(Class I earth connection warning) |
- |
0 |
|
- |
| Cl.5.5.2 e) of Cl.5.5(Instructions for multimedia system connection) |
- |
0 |
|
- |
| Cl.5.5.2 f) of Cl.5.5(Special stability warning for attachment of the apparatus to the floor/wall) |
- |
0 |
|
- |
| Cl.5.5.2 g) of Cl.5.5(Warning: battery exposure to heat) |
- |
0 |
|
- |
| Cl.5.5.2 h) of Cl.5.5(Warning: protective film on CRT face) |
- |
0 |
|
- |
| Cl.5.5.2 i) of Cl.5.5("Warning: Non-floor standing TV
>7kg") |
- |
0 |
|
- |
| Cl.5.5.2 j) of Cl.5.5("Warning: User replaceable coin
/ button cell battery") |
- |
0 |
|
- |
| Cl.5.5.3 (a-b) of Cl.5.5(Disconnect device: plug/coupler or all-pole mains switch location, accessibility and markings) |
- |
0 |
|
- |
| Cl.5.5.3 c) of Cl.5.5(Instructions for permanently connected equipment) |
- |
0 |
|
- |
| Cl.5.5.3 c) i) of Cl.5.5(Marking, signal lamps or similar for completely disconnection from the mains) |
- |
0 |
|
- |
| Cl.7.1 of Cl.7(General) |
- |
0 |
|
- |
| "Cl.7.1.1 of Cl.7.1 Table-3"(Requirements) |
- |
0 |
|
- |
| "Cl.7.1.2 of Cl.7.1 Table-3"(Accessible parts) |
- |
0 |
|
- |
| "Cl.7.1.3 of Cl.7.1 Table-3"(Parts, other than windings and printed boards, providing electrical insulation) |
- |
0 |
|
- |
| "Cl.7.1.4 of Cl.7.1 Table-3"(Parts acting as a support or a mechanical barrier) |
- |
0 |
|
- |
| "Cl.7.1.5 of Cl.7.1 Table-3"(Windings) |
- |
0 |
|
- |
| "Cl.7.1.6 of Cl.7.1 Table-3"(Parts not subject to a limit under7.1.1 to 7.1.4) |
- |
0 |
|
- |
| Cl.7.2 of Cl.7(Softening temperature of insulating material supporting parts conductively connected to the mains carrying a current> 0.2 A, shall be at least 150ºC) |
- |
0 |
|
- |
| Cl.8.1 of Cl.8(Conductive parts covered by lacquer, paper, untreated textile oxide films and beads etc. considered to be bare*) |
- |
0 |
|
- |
| Cl.8.2 of Cl.8(No shock hazard when changing voltage setting device, fuse-links or handling drawers etc.) |
- |
0 |
|
- |
| Cl.8.3 of Cl.8(Insulation of hazardous live parts not provided by hygroscopic material) |
- |
0 |
|
- |
| Cl.8.4 of Cl.8(No risk of electric shock from accessible parts or from parts rendered accessible following the removal of a cover which can be removed by hand) |
- |
0 |
|
- |
| Cl.8.5 of Cl.8(Class I apparatus*) |
- |
0 |
|
- |
| Cl.8.5 ii) of Cl.8(Resistors bridging basic insulation shall complying with 14.1 a) *) |
- |
0 |
|
- |
| Cl.8.5 iii) of Cl.8(Capacitors bridging basic insulation shall complying with 14.2.1 a) *) |
- |
0 |
|
- |
| Cl.8.5 iv) of Cl.8(Protective earthing terminal *) |
- |
0 |
|
- |
| Cl.8.6 of Cl.8(Class II apparatus) |
- |
0 |
|
- |
| Cl.8.6 a) of Cl.8(Basic and supplementary insulation between hazardous live parts and accessible parts *) |
- |
0 |
|
- |
| Cl.8.6 b) of Cl.8(Reinforced insulation between hazardous live parts and accessible parts *) |
- |
0 |
|
- |
| Cl.8.7 of Cl.8(Components bridging insulation) |
- |
0 |
|
- |
| Cl.8.7 i) of Cl.8(Basic insulation bridged by components complying with 14.4.5.3) |
- |
0 |
|
- |
| Cl.8.7 ii) of Cl.8(Components bridging basic, supplementary, double or reinforced insulation complying with 14.2 a) or 14.4) |
- |
0 |
|
- |
| Cl.8.7 iii) of Cl.8(Basic and supplementary insulation each being bridged by a capacitor or RC-unit complying with 14.3.2 a)) |
- |
0 |
|
- |
| Cl.8.7 iv) of Cl.8(Double or reinforced insulation being bridged with 2 capacitors or RC-units in series complying with 14.3.2 a)) |
- |
0 |
|
- |
| Cl.8.7 v) of Cl.8(Double or reinforced insulation being bridged with a single capacitor or RC-unit complying with 14.3.2 b)) |
- |
0 |
|
- |
| Cl.8.8 of Cl.8(Insulation thickness and thin sheet materials) |
- |
0 |
|
- |
| Cl.8.8 i) of Cl.8(Basic or supplementary insulation > 0,4 mm (mm)*) |
- |
0 |
|
- |
| Cl.8.8 ii) of Cl.8(Reinforced insulation > 0,4 mm (mm) *) |
- |
0 |
|
- |
| Cl.8.8 iii) of Cl.8(Thin sheet material used inside the equipment) |
- |
0 |
|
- |
| Cl.8.8 iv) of Cl.8(Basic or supplementary insulation, atleast two layers, each meeting10.4) |
- |
0 |
|
- |
| Cl.8.8 v) of Cl.8(Basic or supplementary insulation, three layers any two of which meet10.4) |
- |
0 |
|
- |
| Cl.8.8 vi) of Cl.8(Reinforced insulation, two layers each of which meet 10.4) |
- |
0 |
|
- |
| Cl.8.9 of Cl.8(Adequate insulation between internal hazardous live conductors and accessible parts, or between internal hazardous live parts and conductors connected to accessible parts) |
- |
0 |
|
- |
| Cl.8.10 of Cl.8(Double insulation between accessible parts and conductors connected to the mains) |
- |
0 |
|
- |
| Cl.8.10 of Cl.8(Double insulation between conductors connected to accessible parts and parts connected to the mains) |
- |
0 |
|
- |
| Cl.8.11 of Cl.8(Detaching of wires) |
- |
0 |
|
- |
| Cl.8.11 i) of Cl.8(Noun due reduction of creepage or clearance distances if wires become detached) |
- |
0 |
|
- |
| Cl.8.11 ii) of Cl.8(Vibration test carried out) |
- |
0 |
|
- |
| Cl.8.12 of Cl.8(Adequate fastening of windows, lenses, lamp covers etc. (pull test 20 N for 10 s)) |
- |
0 |
|
- |
| Cl.8.13 of Cl.8(Adequate fastening of windows, lenses, lamp covers etc. (pull test 20 N for 10 s)) |
- |
0 |
|
- |
| Cl.8.14 of Cl.8(No risk of damage to the insulation of internal wiring due to hot parts or sharp edges) |
- |
0 |
|
- |
| Cl.8.15 of Cl.8(Only special supply equipment can be used*) |
- |
0 |
|
- |
| Cl.8.18 of Cl.8(Disconnection from the mains) |
- |
0 |
|
- |
| Cl.8.18 i) of Cl.8(Disconnect device used in apparatus) |
- |
0 |
|
- |
| Cl.8.18 ii) of Cl.8(All-pole switch or circuit breaker with >3mm contact separation.) |
- |
0 |
|
- |
| Cl.8.18 iii) of Cl.8(Mains switch ON indication *) |
- |
0 |
|
- |
| Cl.8.19 of Cl.8(Switch not fitted in the mains cord *) |
- |
0 |
|
- |
| Cl.8.20 of Cl.8(Bridging components comply with clause 14) |
- |
0 |
|
- |
| Cl.8.21 of Cl.8(Non-separable thin sheet material) |
- |
0 |
|
- |
| Cl.9.1 of Cl.9(Testing on the outside) |
- |
0 |
|
- |
| Cl.9.1.1 of Cl.9.1(Requirements) |
- |
0 |
|
- |
| Cl.9.1.1 i) of Cl.9.1(Accessible parts shall not be hazardous live) |
- |
0 |
|
- |
| Cl.9.1.1 ii) of Cl.9.1(Inaccessible terminals are not accessible or comply with relevant requirements) |
- |
0 |
|
- |
| Cl.9.1.1 iii) of Cl.9.1(For voltages >1000 V ac or >1500 V dc complies with clause 13.3.1 for basic insulation) |
- |
0 |
|
- |
| Cl.9.1.1.2 of Cl.9.1.1(Determination of hazardous live parts) |
- |
0 |
|
- |
| Cl.9.1.1.2 a) of Cl.9.1.1(Open circuit voltages) |
- |
0 |
|
- |
| Touch current measured from terminal devices using the network in annex D(Touch current measured from terminal devices using the network in annex D) |
- |
0 |
|
- |
| Cl.9.1.1.2 c) of Cl.9.1.1(The charge exceeds 45 μC) |
- |
0 |
|
- |
| Cl.9.1.1.2 d) of Cl.9.1.1(Energy of discharge not exceeding 350 mJ) |
- |
0 |
|
- |
| Cl.9.1.1.3 of Cl.9.1.1(Test with test finger and test probe) |
- |
0 |
|
- |
| Cl.9.1.2 of Cl.9.1(Shafts of operating knobs, handles, levers and the like) |
- |
0 |
|
- |
| Cl.9.1.3 of Cl.9.1(Openings ofthe enclosure) |
- |
0 |
|
- |
| Cl.9.1.4 of Cl.9.1(Terminals) |
- |
0 |
|
- |
| Cl.9.1.4 i) of Cl.9.1(Terminals) |
- |
0 |
|
- |
| Cl.9.1.4 ii) of Cl.9.1(Terminals) |
- |
0 |
|
- |
| Cl.9.1.5 of Cl.9.1(Pre-set controls) |
- |
0 |
|
- |
| Cl.9.1.6 of Cl.9.1(Withdrawal of the mains plug:) |
- |
0 |
|
- |
| Cl.9.1.6 i) of Cl.9.1(Withdrawal of the mains plug:) |
- |
0 |
|
- |
| Cl.9.1.6 ii) of Cl.9.1(Withdrawal of the mains plug:) |
- |
0 |
|
- |
| Cl.9.1.6 iii) of Cl.9.1(Withdrawal of the mains plug:) |
- |
0 |
|
- |
| Cl.9.1.7 of Cl.9.1(Resistance to external forces) |
- |
0 |
|
- |
| Cl.9.1.7 a) of Cl.9.1(Resistance to external forces) |
- |
0 |
|
- |
| Cl.9.1.7 b) of Cl.9.1(Resistance to external forces) |
- |
0 |
|
- |
| Cl.9.1.7 c) of Cl.9.1(Resistance to external forces) |
- |
0 |
|
- |
| Cl.9.2 of Cl.9(Removal of protective covers) |
- |
0 |
|
- |
| Cl.10.2 of Cl.10(Surge Test) |
- |
0 |
|
- |
| Cl.10.2 a) of Cl.10(Surge Test) |
- |
0 |
|
- |
| Cl.10.2 b) of Cl.10(Surge Test) |
- |
0 |
|
- |
| Cl.10.2 b) (i) of Cl.10(Surge Test) |
- |
0 |
|
- |
| Cl.10.2 b) (ii) of Cl.10(Surge Test) |
- |
0 |
|
- |
| Cl.10.2 b) (iii) of Cl.10(Surge Test) |
- |
0 |
|
- |
| Cl.10.3 of Cl.10(Humidity treatment) |
- |
0 |
|
- |
| Cl.10.4 of Cl.10(Insulation resistance and dielectric strength) |
- |
0 |
|
- |
| Cl.10.4.1 of Cl.10.4(Insulation of the insulating materials) |
- |
0 |
|
- |
| Cl.10.4.2 of Cl.10.4(Between parts of different polarity directly connected to the mains
Between parts of different polarity directly connected to the mains) |
- |
0 |
|
- |
| Cl.10.4.2 i) of Cl.10.4(Between parts separated by BASIC or SUPPLEMENTARY insulation) |
- |
0 |
|
- |
| Cl.10.4.2 ii) of Cl.10.4(Between parts separated by REINFORCED insulation) |
- |
0 |
|
- |
| Cl.11.1 of Cl.11(Electric Shock Hazard) |
- |
0 |
|
- |
| Cl.11.1 a) of Cl.11(Electric Shock Hazard) |
- |
0 |
|
- |
| Cl.11.1 b) of Cl.11(Electric Shock Hazard) |
- |
0 |
|
- |
| Cl.11.2 of Cl.11(Heating) |
- |
0 |
|
- |
| Cl.11.2.1 of Cl.11.2(Requirements) |
- |
0 |
|
- |
| Cl.11.2.1 i) of Cl.11.2(No danger of fire to the surroundings) |
- |
0 |
|
- |
| Cl.11.2.1 ii) of Cl.11.2(Safety not impaired by abnormal heat) |
- |
0 |
|
- |
| Cl.11.2.1 of Cl.11.2(Flames extinguish within 10 seconds) |
- |
0 |
|
- |
| Cl.11.2.1 of Cl.11.2(No hazard from softening solder) |
- |
0 |
|
- |
| Cl.11.2.1 of Cl.11.2(Soldered terminations not used as protective mechanism) |
- |
0 |
|
- |
| Cl.11.2.2 of Cl.11.2(Measurement of temperature rises) |
- |
0 |
|
- |
| Cl.11.2.3 of Cl.11.2(Accessible parts) |
- |
0 |
|
- |
| Cl.11.2.4 of Cl.11.2(Parts, other than windings and printed boards, providing electrical insulation) |
- |
0 |
|
- |
| Cl.11.2.5 of Cl.11.2(Parts acting as a support or a mechanical barrier) |
- |
0 |
|
- |
| Cl.11.2.6 of Cl.11.2(Windings ) |
- |
0 |
|
- |
| Cl.11.2.7 of Cl.11.2(Printed boards) |
- |
0 |
|
- |
| Cl.11.2.7 i) of Cl.11.2(Printed boards) |
- |
0 |
|
- |
| Cl.11.2.7 i) a) of Cl.11.2(Printed boards) |
- |
0 |
|
- |
| Cl.11.2.7 i) b) of Cl.11.2(Printed boards) |
- |
0 |
|
- |
| Cl.11.2.7 ii) of Cl.11.2(Printed boards) |
- |
0 |
|
- |
| Cl.11.2.7 iii) of Cl.11.2(Printed boards) |
- |
0 |
|
- |
| Cl.11.2.8 of Cl.11.2(Parts not subject to a limit under7.1.1 to 7.1.4) |
- |
0 |
|
- |
| Cl.12.1.1 of Cl.12.1(Requirements) |
- |
0 |
|
- |
| Cl.12.1.2 of Cl.12.1(Bump test ) |
- |
0 |
|
- |
| Cl.12.1.3 of Cl.12.1(Vibration test) |
- |
0 |
|
- |
| Cl.12.1.4 of Cl.12.1(Impact test) |
- |
0 |
|
- |
| Cl.12.1.4 i) of Cl.12.1(Impact test) |
- |
0 |
|
- |
| Cl.12.1.4 ii) of Cl.12.1(Impact test) |
- |
0 |
|
- |
| Cl.12.1.5 of Cl.12.1(Drop test) |
- |
0 |
|
- |
| Cl.12.1.6 of Cl.12.1(Stress relief test) |
- |
0 |
|
- |
| Cl.12.2 of Cl.12(Fixing of actuating elements) |
- |
0 |
|
- |
| Cl.12.3 of Cl.12(Remote control devices held in hand) |
- |
0 |
|
- |
| Cl.12.4 of Cl.12(Drawers ) |
- |
0 |
|
- |
| Cl.12.5 of Cl.12(Antenna coaxial sockets mounted on the apparatus) |
- |
0 |
|
- |
| Cl.12.5 a) of Cl.12(Endurance test,) |
- |
0 |
|
- |
| Cl.12.5 b) of Cl.12(Impact test,) |
- |
0 |
|
- |
| Cl.12.5 c) of Cl.12(Torque test) |
- |
0 |
|
- |
| Cl.12.6 of Cl.12(Telescoping or rod antennas) |
- |
0 |
|
- |
| Cl.12.6.1 of Cl.12.6(General requirements) |
- |
0 |
|
- |
| Cl.12.6.1 i) of Cl.12.6(General requirements) |
- |
0 |
|
- |
| Cl.12.6.2 of Cl.12.6(Physical securement) |
- |
0 |
|
- |
| Cl.12.7 of Cl.12(Apparatus containing coin / button cell batteries) |
- |
0 |
|
- |
| Cl.12.7.1 of Cl.12.7(Coin/button cell batteries with a diameter of 32 mm or less.) |
- |
0 |
|
- |
| Cl.12.7.2 of Cl.12.7(Construction requirementss) |
- |
0 |
|
- |
| Cl.12.7.3 of Cl.12.7(Tests) |
- |
0 |
|
- |
| Cl.12.7.3.2 of Cl.12.7.3(Stress relief test) |
- |
0 |
|
- |
| Cl.12.7.3.3 of Cl.12.7.3(Battery replacement test) |
- |
0 |
|
- |
| Cl.12.7.3.4 of Cl.12.7.3(Drop test) |
- |
0 |
|
- |
| Cl.12.7.3.5 of Cl.12.7.3(Impact test) |
- |
0 |
|
- |
| Cl.12.7.3.6 of Cl.12.7.3(Crush test) |
- |
0 |
|
- |
| Cl.12.7.4 of Cl.12.7(Compliance) |
- |
0 |
|
- |
| Cl.13.1 of Cl.13(General) |
- |
0 |
|
- |
| Cl.13.2 of Cl.13(Determination of Working voltage) |
- |
0 |
|
- |
| Cl.13.3 of Cl.13(Clearances) |
- |
0 |
|
- |
| Cl.13.3.1 of Cl.13.3(General) |
- |
0 |
|
- |
| Cl.13.3.2 of Cl.13.3(Clearances in circuits conductively connected to the mains) |
- |
0 |
|
- |
| Cl.13.3.3 of Cl.13.3(Clearances in circuits not conductively connected to the mains) |
- |
0 |
|
- |
| Cl.13.3.4 of Cl.13(Measurement of transient voltages) |
- |
0 |
|
- |
| Cl.13.4 a) of Cl.13(Creepage distances ) |
- |
0 |
|
- |
| Cl.13.4 b) of Cl.13(Creepage distances ) |
- |
0 |
|
- |
| Cl.13.4 c) of Cl.13(Creepage distances ) |
- |
0 |
|
- |
| Cl.13.6 a) of Cl.13(Jointed insulation ) |
- |
0 |
|
- |
| Cl.13.6 b) of Cl.13(Jointed insulation ) |
- |
0 |
|
- |
| Cl.13.6 c) of Cl.13(Jointed insulation ) |
- |
0 |
|
- |
| Cl.13.6 d) of Cl.13(Jointed insulation ) |
- |
0 |
|
- |
| Cl.13.7 of Cl.13(Enclosed and sealed parts) |
- |
0 |
|
- |
| Cl.13.8 of Cl.13(Parts filled with insulating compound, meeting the requirements of 8.8) |
- |
0 |
|
- |
| Cl.15.1 of Cl.15(Plugs and Sockets*) |
- |
0 |
|
- |
| Cl.15.1.1 of Cl.15.1(Plugs and Sockets*) |
- |
0 |
|
- |
| Cl.15.1.1 i) of Cl.15.1(Plugs and Sockets*) |
- |
0 |
|
- |
| Cl.15.1.1 ii) of Cl.15.1(Plugs and Sockets*) |
- |
0 |
|
- |
| Cl.15.1.2 of Cl.15.1(Design of connectors other than for mains power *) |
- |
0 |
|
- |
| Cl.15.1.2 i) of Cl.15.1(Design of sockets with symbol of 5.3 b) design *) |
- |
0 |
|
- |
| Cl.15.1.3 of Cl.15.1(Design of terminals and connectors used in output circuits of supply apparatus*) |
- |
0 |
|
- |
| Cl.15.2 of Cl.15(Provisions for protective earthing) |
- |
0 |
|
- |
| Cl.15.2 i) of Cl.15(Provisions for protective earthing) |
- |
0 |
|
- |
| Cl.15.2 ii) of Cl.15(Provisions for protective earthing) |
- |
0 |
|
- |
| Cl.15.2 iii) of Cl.15(Provisions for protective earthing) |
- |
0 |
|
- |
| Cl.15.2 iv) of Cl.15(Provisions for protective earthing) |
- |
0 |
|
- |
| Cl.15.2 v) of Cl.15(Provisions for protective earthing) |
- |
0 |
|
- |
| Cl.15.3 of Cl.15(Terminals for external flexible cords and for permanent connection to the mains supply*) |
- |
0 |
|
- |
| Cl.15.3.1 of Cl.15.3(Adequate terminals for connection of permanent wiring*) |
- |
0 |
|
- |
| Cl.15.3.2 of Cl.15.3(Reliable connection of non-detachable cords) |
- |
0 |
|
- |
| Cl.15.3.2 i) of Cl.15.3(Not soldered to conductors of a printed circuit board) |
- |
0 |
|
- |
| Cl.15.3.2 ii) of Cl.15.3(Adequate clearances and creepage distances between connections should a wire break away) |
- |
0 |
|
- |
| Cl.15.3.2 iii) of Cl.15.3(Wire secured by additional means to the conductor) |
- |
0 |
|
- |
| Cl.15.3.3 of Cl.15.3(Screws and nuts clamping conductors have adequate threads: ISO 261, ISO 262 or similar*) |
- |
0 |
|
- |
| Cl.15.3.4 of Cl.15.3(Conductors adequately fixed (two independent fixings) *) |
- |
0 |
|
- |
| Cl.15.3.5 of Cl.15.3(Terminals allow connection of conductors having appropriate cross-sectional area) |
- |
0 |
|
- |
| Cl.15.3.6 of Cl.15.3(Terminals to 15.3.3 have sizes required by table 16) |
- |
0 |
|
- |
| Cl.15.3.7 of Cl.15.3(Terminals clamp conductors between metal and have adequate pressure) |
- |
0 |
|
- |
| Cl.15.3.7 i) of Cl.15.3(Terminals designed to avoid conductor slipping out when tightened) |
- |
0 |
|
- |
| Cl.15.3.7 ii) of Cl.15.3(Terminals adequately fixed when tightened or loosened (no loosening, wiring not stressed, distances not reduced)) |
- |
0 |
|
- |
| Cl.15.3.8 of Cl.15.3(Terminals carrying a current more than) |
- |
0 |
|
- |
| Cl.15.3.8 i) of Cl.15.3(0.2 A, contact pressure not transmitted by insulating material except ceramic*) |
- |
0 |
|
- |
| Cl.15.3.9 of Cl.15.3(Termination of non-detachable cords: wires terminated near to each other) |
- |
0 |
|
- |
| Cl.15.3.9 i) of Cl.15.3(Terminals located and shielded: test with 8 mm strand) |
- |
0 |
|
- |
| Cl.15.4 of Cl.15(Devices forming a part of the mains plug*) |
- |
0 |
|
- |
| Cl.15.4.1 of Cl.15.4(No undue strain on mains socket-outlets.) |
- |
0 |
|
- |
| Cl.15.4.1 i) of Cl.15.4(Device shall be tested on the equipment as per Fig.11: Torque to be applied : 0.25 Nm (Max)) |
- |
0 |
|
- |
| Cl.15.4.2 of Cl.15.4(Device complies with standard for dimensions of mains plugs) |
- |
0 |
|
- |
| Cl.15.4.3 of Cl.15.4(Device has adequate mechanical strength (tests a,b,c)) |
- |
0 |
|
- |
| Cl.16.1 a) of Cl.16(Mains supply flexible cords shall be sheathed type, complying with IEC 60227 for PVC cords or as per IEC 60245 for synthetic rubber cords) |
- |
0 |
|
- |
| Cl.16.1 b) of Cl.16(Non-detachable cords for Class I have green/yellow core for protective earth) |
- |
0 |
|
- |
| Cl.16.2 of Cl.16(Mains cords conductors shall have a nominal cross-sectional area not less than the values given in Table 18, for rated current consumption of the apparatus) |
- |
0 |
|
- |
| Cl.16.3 a) of Cl.16(Flexiblecordsnotcomplyingwith16.1, used for interconnections between separate units of equipment used in combination and carrying hazardous live voltages, have adequate dielectric strength as perCl.10.3) |
- |
0 |
|
- |
| Cl.16.4 of Cl.16(Flexible cords used for connection between equipment have adequate cross-sectional areas to avoid temperature rise under normal and fault conditions) |
- |
0 |
|
- |
| Cl.16.5 a) of Cl.16(Adequate strain relief on external flexible cords) |
- |
0 |
|
- |
| Cl.16.5 b) of Cl.16(Not possible to push cord back into equipment) |
- |
0 |
|
- |
| Cl.16.5 c) of Cl.16(Strain relief device unlikely to damage flexible cord) |
- |
0 |
|
- |
| Cl.16.5 d) of Cl.16(For mains cords of Class I equipment, hazardous live conductors become taut before earth conductor) |
- |
0 |
|
- |
| Cl.16.6 of Cl.16(Apertures for external flexible cord: no risk of damage to the cord during assembly or movement in use) |
- |
0 |
|
- |
| Cl.16.7 a) of Cl.16(Transportable apparatus fitted with detachable cord sets with appliance inlet as perIEC60320-1 or) |
- |
0 |
|
- |
| Cl.16.7 b) of Cl.16(Transportable apparatus shall have a means of stowage to protect the cord) |
- |
0 |
|
- |
| 17.1 a) of Cl.17(Screws are loosened and then tightened with a torque according to table20) |
- |
0 |
|
- |
| Cl.17.1 b) of Cl.17(5 times in the case of screws operating in a thread of metal) |
- |
0 |
|
- |
| Cl.17.1 c) of Cl.17(10 times in the case of screws operating in wood or in a thread in insulating material:) |
- |
0 |
|
- |
| Cl.17.2 of Cl.17(Correct introduction of screws into female threads in non-metallic material) |
- |
0 |
|
- |
| Cl.17.3 a) of Cl.17(Screws or other fixing devices intended to fix Covers, legs, stands or the like, shall be captive in order to prevent replacement during servicing by screws or other fixing devices……) |
- |
0 |
|
- |
| Cl.17.3 b) of Cl.17(Non-captive fixing screws: no hazard when replaced by a screw whose length is 10 times its diameter) |
- |
0 |
|
- |
| Cl.17.4 of Cl.17(No loosening of conductive parts carrying a current > 0.2 A) |
- |
0 |
|
- |
| Cl.17.5 of Cl.17(Contact pressure not transmitted through plastic other than ceramic for connections carrying a current > 0.2 A*) |
- |
0 |
|
- |
| Cl.17.6 of Cl.17(Stranded conductors of flexible supply cords carrying a current > 0.2 A with screw terminals not consolidated by solder *) |
- |
0 |
|
- |
| Cl.17.7 of Cl.17(Cover fixing devices other than screws have adequate strength and their positioning is unambiguous) |
- |
0 |
|
- |
| Cl.17.8 of Cl.17(Detachable legs or stands supplied by the manufacturer of the apparatus shall be delivered with the relevant fixing means *) |
- |
0 |
|
- |
| Cl.17.9 a) of Cl.17(Internal pluggable connections, affecting safety, unlikely to become disconnected) |
- |
0 |
|
- |
| Cl.17.9 b) of Cl.17(By applying a 2N pull force in any direction to the connection, in case of doubt) |
- |
0 |
|
- |
| Cl.19.1 of Cl.19(Stability and mechanical hazards) |
- |
0 |
|
- |
| Cl.19.1 of Cl.19(Stability requirements) |
- |
0 |
|
- |
| Cl.19.1 i) of Cl.19(Stability requirements) |
- |
0 |
|
- |
| Cl.19.2 of Cl.19(Test at 10° to the horizontal) |
- |
0 |
|
- |
| Cl.19.3 of Cl.19(Vertical force test ) |
- |
0 |
|
- |
| Cl.19.4 of Cl.19(Horizontal force test) |
- |
0 |
|
- |
| Cl.19.5 of Cl.19(Test of edges and corners) |
- |
0 |
|
- |
| Cl.19.6 of Cl.19(Mechanical strength of glass) |
- |
0 |
|
- |
| Cl.19.6.1 of Cl.19.6(Requirements) |
- |
0 |
|
- |
| Cl.19.6.2 of Cl.19.6(Fragmentation test) |
- |
0 |
|
- |
| Cl.19.7 of Cl.19(Wall or ceiling mounting means) |
- |
0 |
|
- |
| Cl.19.7.1 of Cl.19..7(Requirements) |
- |
0 |
|
- |
| Cl.19.7.3 of Cl.19.7(Compliance) |
- |
0 |
|
- |
| Cl.20.1 of Cl.20(Requirements) |
- |
0 |
|
- |
| Cl.20.2 of Cl.20(Electrical components and mechanical parts) |
- |
0 |
|
- |
| Cl.20.2.1 a) of Cl.20.2(Exemption for components contained in an enclosure of material V-0 to IEC60695- 11-10 with openings not exceeding 1 mm in width) |
- |
0 |
|
- |
| Cl.20.2.1 b) of Cl.20.2(Exemption for small components) |
- |
0 |
|
- |
| Cl.20.2.2 of Cl.20.2(Electrical components ) |
- |
0 |
|
- |
| Cl.20.2.3 of Cl.20.2(Internal wiring) |
- |
0 |
|
- |
| Cl.20.2.5 of Cl.20.2(Components and parts not covered by 20.2.2, 20.2.3 and 20.2.4) |
- |
0 |
|
- |
| Cl.20.2.5 i) of Cl.20.2(Components and parts not covered by 20.2.2, 20.2.3 and 20.2.4) |
- |
0 |
|
- |
| Cl.20.2.5 ii) of Cl.20.2(Components and parts not covered by 20.2.2, 20.2.3 and 20.2.4) |
- |
0 |
|
- |
| Cl.20.3 of Cl.20(Fire enclosure*) |
- |
0 |
|
- |
| Cl.20.3.1 of Cl.20.3(Fire enclosure*) |
- |
0 |
|
- |
| Cl.20.3.2 of Cl.20.3(Fire enclosure*) |
- |
0 |
|
- |
| Cl.20.3.3 of Cl.20.3(Fire enclosure*) |
- |
0 |
|
- |
| 8.16/ H 2.2/ H 2.3(Requirements for insulated winding wires for use without additional interleaved insulation) |
- |
0 |
|
- |
| 8.16(Wound Component) |
- |
0 |
|
- |
| Cl.5.2 h)-i) of Cl.5(appliance coupler for Class I is used for Class II equipment with functional earth connection, the requirements of Clause 15 and Clause 16 related to Class I construction shall be applied up to the connecting point of the protective(earthing) conductor to the functional earth.) |
- |
0 |
|
- |
| Cl.5.5 of Cl.5(Instructions) |
- |
0 |
|
- |
| Cl.5.5 of Cl.5(Instructions) |
- |
0 |
|
- |
| Cl.8.5 i) of Cl.8(Basic insulation between hazardous live parts and earthed accessible parts *) |
- |
0 |
|
- |
| Cl.8.16 of Cl.8(Insulated winding wire without additional interleaved insulation) |
- |
0 |
|
- |
| Cl.20.2.4 of Cl.20.2(Printed boards) |
- |
0 |
|
- |
| Cl.20.2.4 i) of Cl.20.2(Printed boards) |
- |
0 |
|
- |
| 14(Components) |
- |
0 |
|
- |
| 15(Internal wires and power cords) |
- |
0 |
|
- |
| 18(Mechanical strength of Picture tubes and protection against the effect of implosion) |
- |
0 |
|
- |
|
11 Sep, 2027 |
- Exclusion: Cl.6.1 (Inonization radiation), Cl.6.2 (Laser radiations), Cl.6.3 (Light emitting diodes), Cl.18 (Mechanical strength of picture tubes and protection against the effect of implosion), 16.3b (Cord Bending Test) |
| 15 |
IS 10322 : Part 5 : Sec 1 (2012) |
Luminaires: Part 5 particular requirements: Sec 1 fixed general purpose luminaires (First Revision) |
Fixed General Purpose luminaire |
75000 View breakup
Rs.75,000/- (10% Discount)
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4(General Test Requireements) |
- |
2500 |
|
- |
| 5(Classification of Luminaires') |
- |
2500 |
|
- |
| 6.0(Marking) |
- |
3000 |
|
- |
| 7.0(Construction) |
- |
3000 |
|
- |
| 8.0(Creepage Distance and Clearances) |
- |
3500 |
|
- |
| 9.0(Provision for earthing) |
- |
6000 |
|
- |
| 10.0(Terminals) |
- |
7000 |
|
- |
| 11.0(External & Internal Wiring) |
- |
7500 |
|
- |
| 12.0(Protection against electric shock) |
- |
10000 |
|
- |
| 13.0(Endurance Tests and Thermal Tests) |
- |
10000 |
|
- |
| 14.0(Resistance to Dust & Moisture) |
- |
7000 |
|
- |
| 15.0(Insulation Resistance and Electric Strength) |
- |
10000 |
|
- |
| 16.0(Resistance to Heat , fire and tracking) |
- |
8000 |
|
- |
|
11 Sep, 2027 |
- Exclusion: Cl.4.24 (UV Radiation), Cl.4.11.6 (Electromechanical Contact), Cl.17 (Photometric test) |