21.2 a(Measurement of winding resistance
[IS 2026 (Part 1)].) |
- |
785 |
|
10 % Discount for BIS |
21.2 b(Measurement of voltage ratio and check of phase
displacement [IS 2026 (Part 1)].) |
- |
910 |
|
10 % Discount for BIS |
21.2 c(Measurement of short-circuit impedance
(principal tapping, when applicable) and load
loss at 50 percent and 100 percent load
[IS 2026 (Part 1)].) |
- |
7430 |
|
10 % Discount for BIS |
21.2 d(Measurement of no-load loss and current
[IS 2026 (Part 1)].) |
- |
5950 |
|
10 % Discount for BIS |
21.2 e(Measurement of insulation resistance
[IS 2026 (Part 1)].) |
- |
570 |
|
10 % Discount for BIS |
21.2 f(Induced over-voltage withstand test
[IS 2026 (Part 3)].) |
- |
1240 |
|
10 % Discount for BIS |
21.2 g(Separate-source voltage withstand test
[IS 2026 (Part 3)]) |
- |
1240 |
|
10 % Discount for BIS |
21.5(Pressure and Ester Liquid Leakage Test) |
- |
5950 |
|
10 % Discount for BIS |
21.3 b(Temperature-rise test [IS 2026 (Part 2)].) |
- |
28230 |
|
10 % Discount for BIS |
21.4 a(Determination of sound levels [IS 2026 (Part 10)];) |
- |
2600 |
|
10 % Discount for BIS |
21.4 c(No load current at 112.5 percent voltage
(see 6.9.2, 7.9.2, 8.9.2);) |
- |
1590 |
|
10 % Discount for BIS |
21.4 e(BDV and Moisture content of liquid in the
transformer (IS 16081, IS 16099, IS 16899 or
IS 16659, whichever is applicable).) |
- |
800 |
|
10 % Discount for BIS |
21.4 d(Paint adhesion test — The test is performed as
per ASTM D3359 (Standard Test Methods for
measuring adhesion by tape test).) |
- |
5010 |
|
10 % Discount for BIS |
6.1 Table 1(Standard Ratings) |
- |
0 |
|
NA |
6.2, 7.2, 8.2(Rated Frequency) |
- |
0 |
|
NA |
6.3, 7.3(Nominal System Voltage) |
- |
0 |
|
NA |
6.4(Table 2 Minimum Basic Insulation Level) |
- |
0 |
|
NA |
6.5, 7.5(No-Load Voltage Ratios) |
- |
0 |
|
NA, Already mentioned as above |
6.6, 7.6(Winding Connections and Phase Displacement) |
- |
0 |
|
NA, Already mentioned as above |
6.7(Tapping Range and Tapping Methods) |
- |
0 |
|
na |
6.8(Table 3 Losses and Impedance Values) |
- |
0 |
|
NA, Already mentioned as above |
6.9(Permissible Flux Density and Over Fluxing) |
- |
0 |
|
na |
6.10(Limits of Temperature-rise) |
- |
0 |
|
NA, Already mentioned as above |
7.1(Table 4 Standard Ratings) |
- |
0 |
|
na |
7.4(Table 5 Minimum Basic Insulation Level) |
- |
0 |
|
na |
7.7(Tapping Ranges and Tapping Methods) |
- |
0 |
|
na |
7.8(Losses and Impedance Values) |
- |
0 |
|
NA, Already mentioned as above |
7.9(Permissible Flux Density and Overfluxing) |
- |
0 |
|
na |
7.10(Limits of Temperature Rise) |
- |
0 |
|
NA, Already mentioned as above |
8.1 Table 7(Standard Ratings) |
- |
0 |
|
na |
8.3(Nominal System Voltage) |
- |
0 |
|
na |
8.5(No Load Voltage Ratio) |
- |
0 |
|
NA |
8.6(Number of Phases and Polarity) |
- |
0 |
|
NA |
8.4(Table 8 Minimum Basic Insulation Level) |
- |
0 |
|
NA |
8.8(Losses and Impedance Values) |
- |
0 |
|
NA, Already mentioned as above |
8.9(Permissible Flux Density and Overfluxing) |
- |
0 |
|
NA |
8.10(Limits of Temperature Rise) |
- |
0 |
|
NA, Already mentioned as above |
9(Standard Materials) |
- |
0 |
|
NA |
10(Terminal Arrangement) |
- |
0 |
|
NA |
11(Minimum clearances in air) |
- |
0 |
|
NA |
12(Connectors (Applicable for bare bushing terminations only)) |
- |
0 |
|
NA |
13(Marking) |
- |
0 |
|
NA |
14(Mounting Arrangement) |
- |
0 |
|
NA |
15(Transformer Tank) |
- |
0 |
|
NA |
16(Conservator for non-sealed typetransformers) |
- |
0 |
|
NA |
18(Efficiency and regulation) |
- |
0 |
|
NA |
20(Fittings) |
- |
0 |
|
NA |
6.1(Rating) |
- |
0 |
|
NA |
6.2(Rated Frequceny) |
- |
0 |
|
NA |
6.3(Nominal System Voltage) |
- |
0 |
|
NA |
6.4(Basic Insulation Level) |
- |
0 |
|
NA |
6.5(No-Load Voltage Ratios) |
- |
0 |
|
NA, Already mentioned as above |
6.6(Winding connection and phase displacement) |
- |
0 |
|
NA, Already mentioned as above |
6.7(Tapping range and tapping methods) |
- |
0 |
|
NA |
6.8(Losses and Impedance Value) |
- |
0 |
|
NA, Already mentioned as above |
6.9(Permissible flux density and over fluxing) |
- |
0 |
|
NA |
6.10(Limits of temperature-rise) |
- |
0 |
|
NA, Already mentioned as above |
7("Technical parameters of three phase distribution
transformers higher ") |
- |
0 |
|
NA |
8(Technical parameter of single phase distribution transformers) |
- |
0 |
|
NA |
10(Terminal Arrangement) |
- |
0 |
|
NA, Already mentioned as above |
11(Minimum clearances in air) |
- |
0 |
|
NA |
12(Connectors for bare bushing terminations) |
- |
0 |
|
NA |
13(Marking) |
- |
0 |
|
NA |
15(Trasnformer tank) |
- |
0 |
|
NA |
16(Conservator for non-sealed type transformers) |
- |
0 |
|
NA |
18(Efficiency and regulations) |
- |
0 |
|
NA |
20(Fittings) |
- |
0 |
|
NA |
21.2(Routine Tests) |
- |
0 |
|
NA, Already mentioned as above |
21.4(Special Test) |
- |
0 |
|
NA, Already mentioned as above |
22(Information required with enquiry and order) |
- |
0 |
|
NA |
14(Mounting Arrangement) |
- |
0 |
|
NA |
21.3 d(Pressure test) |
- |
0 |
|
NA, Already mentioned as above |
21.1(General) |
- |
0 |
|
NA |