1 |
IS 16333 : Part 3 (2017) |
Mobile phone handsets: Part 3 indian language support for mobile phone handsets - Specific requirements (First Revision) |
- |
-
|
30000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
5.1(Inputting of text) |
- |
15000 |
|
Nil |
5.2(Message Readability) |
- |
15000 |
|
Nil |
|
Complete
|
|
21 May, 2023 |
- |
2 |
IS 302 : Part 1 (2008) |
Safety of household and similar electrical appliances: Part 1 general requirements (Sixth Revision) |
- |
-
|
50000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
7(Marking and instructions) |
- |
500 |
|
- |
8.1.1(Protection against live parts in all positions) |
- |
500 |
|
- |
8.1.2(Protection against live parts in openings) |
- |
500 |
|
- |
8.1.3(Protection against live parts in visible glowing heating elements) |
- |
500 |
|
- |
8.1.4(Protection against live parts against protective impedance) |
- |
500 |
|
- |
9(Starting of motor operation test requirements and tests) |
- |
500 |
|
- |
10.1(Power input) |
- |
2000 |
|
- |
10.2(Current input) |
- |
2000 |
|
- |
11.2(General) |
- |
500 |
|
- |
11.3(Heating) |
- |
1000 |
|
- |
13.2(Leakage current at operating temperature) |
- |
1000 |
|
- |
13.3(Electric Strength at operating temperature) |
- |
500 |
|
- |
14(Transient Over Voltages) |
- |
2500 |
|
- |
15.1(Ingress Protection test other than IPX0 (IP test)) |
- |
500 |
|
- |
15.2(Spillage Test) |
- |
500 |
|
- |
15.3(Humidity Test) |
- |
500 |
|
- |
16.2(Leakage Current (after Clause 15)) |
- |
500 |
|
- |
16.3(Electric Strength (after clause 15 and 16.2)) |
- |
500 |
|
- |
17(Over Load Protection of Transformers and associated circuits) |
- |
2000 |
|
- |
19(Abnormal Operation) |
- |
2000 |
|
- |
20(Stability test) |
- |
2000 |
|
- |
21(Mechanical Strength Test) |
- |
2000 |
|
- |
22(Construction verification related test) |
- |
2000 |
|
- |
23(General) |
- |
2000 |
|
- |
24(Components) |
- |
2000 |
|
- |
25(Supply connection and external flexible cords) |
- |
2000 |
|
- |
26(Terminals for external conductors) |
- |
2000 |
|
- |
27(Provision for earthing) |
- |
2000 |
|
- |
28(Screw test and connections) |
- |
2000 |
|
- |
29(clearance, creepage distances and solid insulation) |
- |
2000 |
|
- |
30.1(Ball pressure test) |
- |
500 |
|
- |
18(Endurance Test requirements and tests) |
- |
1000 |
|
- |
31(Resistance to Rusting) |
- |
500 |
|
- |
32(Radiation Toxicity and Similar Hazards) |
- |
2000 |
|
- |
|
Complete
|
|
21 May, 2023 |
- |
3 |
IS 10322 : Part 5 : Sec 7 (2017) |
Luminaires: Part 5 particular requirements: Sec 7 lighting chains (First Revision) |
- |
-
|
75000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
20.4(General Test Requireements) |
- |
0 |
|
Visual Test Equipment |
20.5(Classification of Luminaires') |
- |
0 |
|
Visual Test Equipment |
20.6(Marking) |
- |
5000 |
|
Nil |
20.7(Construction) |
- |
5000 |
|
Nil |
20.8(Creepage Distance and Clearances) |
- |
5000 |
|
Nil |
20.9(Provision for earthing) |
- |
6000 |
|
Nil |
20.10(Terminals) |
- |
5000 |
|
Nil |
20.11(External & Internal Wiring) |
- |
5000 |
|
Nil |
20.12(Protection against electric shock) |
- |
5000 |
|
Nil |
20.13(Endurance Tests and Thermal Tests) |
- |
15000 |
|
Nil |
20.14(Resistance to Dust & Moisture) |
- |
10000 |
|
Nil |
20.15(Insulation Resistance and Electric Strength) |
- |
7000 |
|
Nil |
20.16(Resistance to Heat , fire and tracking) |
- |
7000 |
|
Nil |
|
Complete
|
|
21 May, 2023 |
- |
4 |
IS 10322 : Part 5 : Sec 6 (2013) |
Luminaires: Part 5 particular requirements: Sec 6 handlamps |
- |
-
|
- View breakup
For BIS samples: 1.5 times of BIS
testing charges.
For others: Rs.75,000/
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
No Record Found
|
|
Complete
|
|
21 May, 2023 |
- |
5 |
IS 10322 : Part 5 : Sec 1 (2012) |
Luminaires: Part 5 particular requirements: Sec 1 fixed general purpose luminaires (First Revision) |
- |
-
|
- View breakup
Rs.45,000/-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
No Record Found
|
|
Complete
|
|
21 May, 2023 |
- |
6 |
IS 15885 : Part 2 : Sec 13 (2012) |
Safety of lamp controlgear: Part 2 particular requirements: Sec 13 d.c. or a.c. supplied electronic controlgear for led modules |
- |
-
|
45000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
7(Marking) |
- |
2000 |
|
Nil |
8(Protection against accidental contact with live parts) |
- |
8000 |
|
Nil |
9(Terminals) |
- |
3000 |
|
Nil |
10(PROVISION FOR EARTHING) |
- |
5000 |
|
Nil |
11(MOISTURE RESISTANCE) |
- |
3000 |
|
Nil |
12(Electric Strength) |
- |
3000 |
|
Nil |
13(Thermal endurance test for winding of ballasts) |
- |
3000 |
|
Nil |
14(Fault conditions) |
- |
3000 |
|
Nil |
15(Transformer heating) |
- |
3000 |
|
Nil |
16(Construction) |
- |
2000 |
|
Nil |
17(Creepage distance and clearances) |
- |
2000 |
|
Nil |
18(Screws, current carrying parts and connections) |
- |
2000 |
|
Nil |
19(Resistance to heat, fire and tracking) |
- |
3000 |
|
Nil |
20(Resistance to corrosion) |
- |
3000 |
|
Nil |
|
Complete
|
|
21 May, 2023 |
- |
7 |
IS 16102 : Part 1 (2012) |
Self - Ballasted led lamps for general lighting services: Part 1 safety requirements |
- |
-
|
- View breakup
For BIS samples: 1.5 times of BIS
testing charges.
For others : Rs.45,000/-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
5(Marking) |
- |
- |
|
- |
6(Interchangeability) |
- |
- |
|
- |
7(Protection against accidental contact with live parts) |
- |
- |
|
- |
8(Insulation Resistance and Electric Strength) |
- |
- |
|
- |
9(MECHANICAL STRENGTH) |
- |
- |
|
- |
10(cap temperature) |
- |
- |
|
- |
11(Resistance to Heat) |
- |
- |
|
- |
12(Resistance to Flame and Ignition) |
- |
- |
|
- |
13(Fault conditions) |
- |
- |
|
- |
14(Creepage distance and clearances) |
- |
- |
|
- |
|
Complete
|
|
21 May, 2023 |
- |
8 |
IS 13252 : Part 1 (2010) |
Information technology equipment - Safety: Part 1 general requirements (Second Revision) |
- |
-
|
45000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
1.5(Components) |
- |
1500 |
|
nil |
1.7(Markings and instructions) |
- |
1000 |
|
nil |
2.1(Protection from electric shock and energy hazards) |
- |
500 |
|
nil |
2.2(SELV circuits) |
- |
500 |
|
nil |
2.3(TNV circuits) |
- |
1000 |
|
nil |
2.4(Limited current circuits) |
- |
1000 |
|
nil |
2.5(Limited power sources .) |
- |
500 |
|
nil |
2.6(Provisions for earthing and bonding) |
- |
1000 |
|
nil |
2.7(Overcurrent and earth fault protection in primary circuits) |
- |
500 |
|
nil |
2.8(Safety interlocks) |
- |
500 |
|
nil |
2.9(Electrical insulation) |
- |
500 |
|
nil |
2.10(Clearances, creepage distances and distances through insulation) |
- |
1000 |
|
nil |
3.1(General) |
- |
750 |
|
nil |
3.2(Connection to a mains supply) |
- |
1750 |
|
nil |
3.3(Wiring terminals for connection of external conductors) |
- |
1750 |
|
nil |
3.4(Disconnection from the mains supply) |
- |
1750 |
|
nil |
3.5(Interconnection of equipment) |
- |
0 |
|
visual inspection test |
4.1(Stability) |
- |
1500 |
|
nil |
4.2(Mechanical strength) |
- |
1500 |
|
nil |
4.3(Design and construction) |
- |
1000 |
|
nil |
4.4(Protection against hazardous moving parts) |
- |
1500 |
|
nil |
4.5(Thermal requirements) |
- |
1500 |
|
nil |
4.6(Openings in enclosures) |
- |
2000 |
|
nil |
4.7(Resistance to fire) |
- |
1750 |
|
nil |
5.1(Touch current and protective conductor curren) |
- |
1750 |
|
nil |
5.2(Electric strength) |
- |
1750 |
|
nil |
5.3(Abnormal operating and fault conditions) |
- |
1750 |
|
nil |
6.1(Protection of telecommunication network service persons, and users of other equipment connected to the network, from hazards in the equipment) |
- |
2300 |
|
nil |
6.2(Protection of equipment users from overvoltages on networks telecommunication) |
- |
1400 |
|
nil |
6.3(Protection of the telecommunication wiring system from overheating) |
- |
2300 |
|
nil |
7.1(General) |
- |
0 |
|
visual inspection test |
7.2(Protection of cable distribution system service persons, and users of other equipment connected to the system, from hazardous voltages in the equipment) |
- |
1500 |
|
nil |
7.3(Protection of equipment users from overvoltages on the cable distribution system) |
- |
1500 |
|
nil |
7.4(Insulation between primary circuits and cable distribution systems) |
- |
4000 |
|
nil |
1.6(Power interface .) |
- |
1000 |
|
nil |
|
Complete
|
|
21 May, 2023 |
- |
9 |
IS 616 (2017) |
Audio, video and similar electronic apparatus - Safety requirements (Fifth Revision) |
- |
-
|
45000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
5(Marking and instructions) |
- |
2000 |
|
nil |
6(Hazardous radiations) |
- |
0 |
|
visual inspection test |
7(Heating under normal operating conditions) |
- |
8000 |
|
nil |
8(Constructional requirements with regard to the protection against electric shock) |
- |
3000 |
|
nil |
9(Electric shock hazard under normal operating conditions) |
- |
5000 |
|
nil |
11(Fault conditions) |
- |
4000 |
|
nil |
12(Mechanical strength) |
- |
3000 |
|
nil |
13(CLEARANCES and CREEPAGE DISTANCES) |
- |
4000 |
|
nil |
14(Components) |
- |
0 |
|
visual inspection test |
15(TERMINALS) |
- |
3000 |
|
nil |
16(External flexible cords) |
- |
2000 |
|
nil |
17(Electrical connections and mechanical fixings) |
- |
2000 |
|
nil |
18(Mechanical strength of picture tubes and protection against the effects of implosion) |
- |
0 |
|
Exclusion |
19(Stability and mechanical hazards) |
- |
3000 |
|
nil |
20(Resistance to fire) |
- |
3000 |
|
nil |
10(Insulation requirements) |
- |
3000 |
|
nil |
|
Complete
|
|
21 May, 2023 |
- |
10 |
IS 16046 : Part 2 (2018) |
Secondary Cells and Batteries Containing Alkaline or Other Non-Acid Electrolytes ” Safety Requirements for Portable Sealed Secondary Cells and for Batteries Made from Them for Use in Portable Applications Part 2 Lithium Systems ( Second Revision ) |
- |
-
|
70000 View breakup
Rs.70,000/-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
4(Parameter Measurement Tolerances) |
- |
0 |
|
Visual Inspection Test |
5(General Safety Considerations) |
- |
0 |
|
Visual Inspection Test |
5.1(General) |
- |
0 |
|
Visual Inspection Test |
5.2(Insulation and Wiring) |
- |
5000 |
|
Nil |
5.3(Venting) |
- |
0 |
|
Visual Inspection Test |
5.4(Temperature, Voltage and Current Management) |
- |
0 |
|
Visual Inspection Test |
5.5(Terminal Contacts) |
- |
0 |
|
Visual Inspection Test |
5.6(Assembly of Cells into batteries) |
- |
0 |
|
Visual Inspection Test |
5.7(Quality Plan) |
- |
0 |
|
Visual Inspection Test |
5.8(Battery Safety Components) |
- |
0 |
|
Visual Inspection Test |
6(Type Test and Sample Size) |
- |
0 |
|
Visual Inspection Test |
7(Specific requirements and tests) |
- |
0 |
|
Visual Inspection Test |
7.1(Charging procedure for test purposes) |
- |
10000 |
|
Nil |
7.2(Intended Use) |
- |
10000 |
|
Nil |
7.3(Reasonably foreseeable misuse) |
- |
45000 |
|
Nil |
8(Information for safety) |
- |
0 |
|
Visual Inspection Test |
8.1(General) |
- |
0 |
|
Visual Inspection Test |
8.2(Small Cell and battery safety information) |
- |
0 |
|
Visual Inspection Test |
9(Marking) |
- |
0 |
|
Visual Inspection Test |
9.1(Cell Marking) |
- |
0 |
|
Visual Inspection Test |
9.2(Battery Marking) |
- |
0 |
|
Visual Inspection Test |
9.3(Caution for ingestion of small cells and batteries) |
- |
0 |
|
Visual Inspection Test |
9.4(Other information) |
- |
0 |
|
Visual Inspection Test |
10(Packaging) |
- |
0 |
|
Visual Inspection Test |
|
Complete
|
|
21 May, 2023 |
REVISED VERSION
Included on 28.11.2018. Restricted upto 20V,
10Ah. |
11 |
IS 16242 : Part 1 (2014) |
Uninterruptible power systems (UPS): Part 1 general and safety requirements for UPS |
- |
-
|
- View breakup
Rs.35,000/- For UPS /Inverter = 5 KVA
Rs.75,000/- For UPS/ Inverters of
rating = 10 kVA.
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
No Record Found
|
|
Complete
|
|
21 May, 2023 |
- |
12 |
IS 16046 : Part 1 (2018) |
Secondary Cells and Batteries Containing Alkaline or Other Non-Acid Electrolytes ” Safety Requirements for Portable Sealed Secondary Cells and for Batteries Made from Them for Use in Portable Applications Part 1 Nickel Systems ( Second Revision ) |
- |
-
|
80000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
4(Parameter Measurement Tolerances) |
- |
0 |
|
nil |
5(General Safety Considerations) |
- |
0 |
|
nil |
5.1(General) |
- |
0 |
|
nil |
5.2(Insulation and Wiring) |
- |
5000 |
|
nil |
5.3(Venting) |
- |
0 |
|
nil |
5.4(Temperature, Voltage and Current Management) |
- |
0 |
|
nil |
5.5(Terminal Contacts) |
- |
0 |
|
nil |
5.6(Assembly of Cells into batteries) |
- |
0 |
|
nil |
5.7(Quality Plan) |
- |
0 |
|
nil |
6(Tyoe Test amd Sample Size) |
- |
0 |
|
nil |
7(Specific requirements and tests) |
- |
0 |
|
nil |
7.1(Charging procedure for test purposes) |
- |
5000 |
|
nil |
7.2(Intended Use) |
- |
20000 |
|
nil |
7.3(Reasonably foreseeable misuse) |
- |
45000 |
|
nil |
8(Information for safety) |
- |
0 |
|
nil |
8.1(General) |
- |
0 |
|
nil |
8.2(Small Cell and battery safety information) |
- |
5000 |
|
nil |
9(Marking) |
- |
0 |
|
nil |
9.1(Cell Marking) |
- |
0 |
|
nil |
9.2(Battery Marking) |
- |
0 |
|
nil |
9.3(Caution for ingestion of small cells and batteries) |
- |
0 |
|
nil |
9.4(Other information) |
- |
0 |
|
nil |
10(Packaging) |
- |
0 |
|
nil |
|
Complete
|
|
21 May, 2023 |
- |