| 1 |
IS 16103 : Part 1 (2012) |
Led modules for general lighting: Part 1 safety requirements |
- |
38000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 7(Marking) |
- |
1000 |
|
10% Discount to BIS |
| 8(Terminals) |
- |
3500 |
|
10% Discount to BIS |
| 9(PROVISION FOR EARTHING) |
- |
3000 |
|
10% Discount to BIS |
| 10(Protection against accidental contact with live parts) |
- |
2000 |
|
10% Discount to BIS |
| 11(Mositure Resistance and Insulation) |
- |
6000 |
|
10% Discount to BIS |
| 12(Electric Strength) |
- |
6000 |
|
10% Discount to BIS |
| 13(Fault conditions) |
- |
4500 |
|
10% Discount to BIS |
| 16(Creepage distance and clearances) |
- |
2000 |
|
10% Discount to BIS |
| 17(Screws, current carrying parts and connections) |
- |
3000 |
|
10% Discount to BIS |
| 18(Resistance to heat, fire and tracking) |
- |
5000 |
|
10% Discount to BIS |
| 19(Resistance to corrosion) |
- |
2000 |
|
10% Discount to BIS |
| 15(Construction) |
- |
0 |
|
-- |
|
- |
- - |
| 2 |
IS 10322 : Part 5 : Sec 2 (2012) |
Luminaires: Part 5 particular requirements: Sec 2 recessed luminaires (First Revision) |
- |
50000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 8(Creepage Distance and Clearances) |
- |
1000 |
|
10% discount to BIS |
| 9(Provision for earthing) |
- |
2000 |
|
10% discount to BIS |
| 10(Terminals) |
- |
2000 |
|
10% discount to BIS |
| 11(External & Internal Wiring) |
- |
2000 |
|
10% discount to BIS |
| 12(Protection against electric shock) |
- |
1000 |
|
10% discount to BIS |
| 13(Endurance Tests and Thermal Tests) |
- |
2000 |
|
10% discount to BIS |
| 14(Resistance to Dust and Moisture) |
- |
5000 |
|
10% discount to BIS |
| 15(Insulation Resistance and Electric Strength) |
- |
2000 |
|
10% discount to BIS |
| 16(Resistance to Heat , fire and tracking) |
- |
2000 |
|
10% discount to BIS |
| 17(Photometric Test) |
- |
28000 |
|
10% discount to BIS |
| 6(Marking) |
- |
1000 |
|
10% discount to BIS |
| 7(Construction) |
- |
2000 |
|
10% discount to BIS |
|
- |
- - |
| 3 |
IS 10322 : PART 5 : SEC 3 (2012) |
Luminaires: Part 5 particular requirements: Sec 3 luminaires for road and street lighting (First Revision) |
- |
55000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6.0(Marking) |
- |
1000 |
|
10% discount to BIS |
| 7.0(Construction) |
- |
7000 |
|
10% discount to BIS |
| 8.0(Creepage Distance and Clearances) |
- |
1000 |
|
10% discount to BIS |
| 9.0(Provision for earthing) |
- |
2000 |
|
10% discount to BIS |
| 10.0(Terminals) |
- |
2000 |
|
10% discount to BIS |
| 11.0(External & Internal Wiring) |
- |
2000 |
|
10% discount to BIS |
| 12.0(Protection against electric shock) |
- |
1000 |
|
10% discount to BIS |
| 13.0(Endurance Tests and Thermal Tests) |
- |
2000 |
|
10% discount to BIS |
| 14.0(Resistance to Dust & Moisture) |
- |
5000 |
|
10% discount to BIS |
| 15.0(Insulation Resistance and Electric Strength) |
- |
2000 |
|
10% discount to BIS |
| 16.0(Resistance to Heat , fire and tracking) |
- |
2000 |
|
10% discount to BIS |
| 17.0(Photometric Test) |
- |
28000 |
|
10% discount to BIS |
|
- |
- - |
| 4 |
IS 10322 : Part 5 : Sec 1 (2012) |
Luminaires: Part 5 particular requirements: Sec 1 fixed general purpose luminaires (First Revision) |
- |
22000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6.0(Marking) |
- |
1000 |
|
10% discount to BIS |
| 7.0(Construction) |
- |
2000 |
|
10% discount to BIS |
| 8.0(Creepage Distance and Clearances) |
- |
1000 |
|
10% discount to BIS |
| 9.0(Provision for earthing) |
- |
2000 |
|
10% discount to BIS |
| 10.0(Terminals) |
- |
2000 |
|
10% discount to BIS |
| 11.0(External & Internal Wiring) |
- |
2000 |
|
10% discount to BIS |
| 12.0(Protection against electric shock) |
- |
1000 |
|
10% discount to BIS |
| 13.0(Endurance Tests and Thermal Tests) |
- |
2000 |
|
10% discount to BIS |
| 14.0(Resistance to Dust & Moisture) |
- |
5000 |
|
10% discount to BIS |
| 15.0(Insulation Resistance and Electric Strength) |
- |
2000 |
|
10% discount to BIS |
| 16.0(Resistance to Heat , fire and tracking) |
- |
2000 |
|
10% discount to BIS |
| 17.0(Photometric Test) |
- |
0 |
|
-- |
|
- |
- - |
| 5 |
IS 10322 : Part 5 : Sec 7 (2017) |
Luminaires: Part 5 particular requirements: Sec 7 lighting chains (First Revision) |
- |
45000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 20.6(Marking) |
- |
1000 |
|
10% discount to BIS |
| 20.7(Construction) |
- |
5000 |
|
10% discount to BIS |
| 20.8(Creepage Distance and Clearances) |
- |
1000 |
|
10% discount to BIS |
| 20.9(Provision for earthing) |
- |
0 |
|
NIL |
| 20.10(Terminals) |
- |
2000 |
|
10% discount to BIS |
| 20.11(External & Internal Wiring) |
- |
6000 |
|
10% discount to BIS |
| 20.12(Protection against electric shock) |
- |
8000 |
|
10% discount to BIS |
| 20.13(Endurance Tests and Thermal Tests) |
- |
6000 |
|
10% discount to BIS |
| 20.14(Resistance to Dust & Moisture) |
- |
2000 |
|
10% discount to BIS |
| 20.15(Insulation Resistance and Electric Strength) |
- |
7000 |
|
10% discount to BIS |
| 20.16(Resistance to Heat , fire and tracking) |
- |
7000 |
|
10% discount to BIS |
|
- |
- - |
| 6 |
IS 10322 : Part 5 : Sec 6 (2013) |
Luminaires: Part 5 particular requirements: Sec 6 handlamps |
- |
35000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6.0(Marking) |
- |
1000 |
|
10% discount to BIS |
| 7.0(Construction) |
- |
4000 |
|
10% discount to BIS |
| 8.0(Creepage Distance and Clearances) |
- |
1000 |
|
10% discount to BIS |
| 10.0(Terminals) |
- |
2000 |
|
10% discount to BIS |
| 11.0(External & Internal Wiring) |
- |
4000 |
|
10% discount to BIS |
| 12.0(Protection against electric shock) |
- |
1000 |
|
10% discount to BIS |
| 13.0(Endurance Tests and Thermal Tests) |
- |
4000 |
|
10% discount to BIS |
| 14.0(Resistance to Dust & Moisture) |
- |
8000 |
|
10% discount to BIS |
| 15.0(Insulation Resistance and Electric Strength) |
- |
2000 |
|
10% discount to BIS |
| 16.0(Resistance to Heat , fire and tracking) |
- |
6000 |
|
10% discount to BIS |
| 9.0(Provision for earthing) |
- |
2000 |
|
10% discount to BIS |
|
- |
- - |
| 7 |
IS 10322 : Part 5 : Sec 5 (2013) |
Luminaires: Part 5 particular requirements: Sec 5 floodlights (First Revision) |
- |
55000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6.0(Marking) |
- |
1000 |
|
NIL |
| 7.0(Construction) |
- |
7000 |
|
NIL |
| 8.0(Creepage Distance and Clearances) |
- |
1000 |
|
NIL |
| 9.0(Provision for earthing) |
- |
2000 |
|
NIL |
| 10.0(Terminals) |
- |
2000 |
|
NIL |
| 11.0(External & Internal Wiring) |
- |
2000 |
|
NIL |
| 12.0(Protection against electric shock) |
- |
1000 |
|
NIL |
| 13.0(Endurance Tests and Thermal Tests) |
- |
2000 |
|
NIL |
| 14.0(Resistance to Dust & Moisture) |
- |
5000 |
|
NIL |
| 15.0(Insulation Resistance and Electric Strength) |
- |
2000 |
|
NIL |
| 16.0(Resistance to Heat , fire and tracking) |
- |
2000 |
|
NIL |
| 17.0(Photometric Test) |
- |
28000 |
|
NIL |
|
- |
- - |
| 8 |
IS 15885 : Part 2 : Sec 13 (2012) |
Safety of lamp controlgear: Part 2 particular requirements: Sec 13 d.c. or a.c. supplied electronic controlgear for led modules |
- |
35000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 7(Marking) |
- |
1000 |
|
10% discount to BIS |
| 8(Protection against accidental contact with live parts) |
- |
2500 |
|
10% discount to BIS |
| 9(Terminals) |
- |
2000 |
|
10% discount to BIS |
| 10(PROVISION FOR EARTHING) |
- |
2000 |
|
10% discount to BIS |
| 11(MOISTURE RESISTANCE) |
- |
8000 |
|
10% discount to BIS |
| 12(Electric Strength) |
- |
2000 |
|
10% discount to BIS |
| 14(Fault conditions) |
- |
5000 |
|
10% discount to BIS |
| 15(Transformer heating) |
- |
2000 |
|
10% discount to BIS |
| 16(Construction) |
- |
2000 |
|
10% discount to BIS |
| 17(Creepage distance and clearances) |
- |
2000 |
|
10% discount to BIS |
| 18(Screws, current carrying parts and connections) |
- |
2000 |
|
10% discount to BIS |
| 19(Resistance to heat, fire and tracking) |
- |
3500 |
|
10% discount to BIS |
| 20(Resistance to corrosion) |
- |
1000 |
|
10% discount to BIS |
| 13(Thermal endurance test for winding of ballasts) |
- |
500 |
|
10% discount to BIS |
|
- |
- - |