| 1 |
IS 2553 : Part 3 (2019) |
Safety glass - Specification: Part 3 solar applications |
Toughened Glass |
68950.00 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4.1(Raw Material) |
- |
5200.00 |
|
- |
| 4.2 & 6(Dimensions) |
- |
5200.00 |
|
- |
| 4.2 & 6(Squareness) |
- |
5200.00 |
|
- |
| 4.2 & 6(Flatness) |
- |
5200.00 |
|
- |
| 4.2 & 6(Fragmentation) |
- |
6150.00 |
|
- |
| 4.2 & 6(Resistance to Shock (Ball Drop)) |
- |
25200.00 |
|
- |
| 4.2 & 6(Mechanical Strength) |
- |
15750.00 |
|
- |
| 5.2(Marking) |
- |
1050.00 |
|
- |
|
13 Nov, 2028 |
- - |
| 2 |
IS 14900 (2018) |
Transparent float glass - Specification (First Revision) |
Transparent Float Glass |
98775.00 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl 4.1(A glass shall be deemed to be manufactured using float glass technology if the tin side of the glass can be identified by the UV light test as prescribed in Annex A.) |
- |
5800.00 |
|
- |
| Cl.4.2 ( Annexure B Table 1)(The minimum value for visual light transmission for a flat, transparent clear float glass, when measured as per Annex B, shall be as prescribed in Table 1) |
- |
5800.00 |
|
- |
| Cl.4.3.1 (Table 2)(Float glass thickness shall be measured with micrometer or calipers, which is graduated to 0.01 mm or with a measuring instrument having an equivalent accuracy. The tolerances on thickness shall be as specified in Table 2.) |
- |
5800.00 |
|
- |
| Cl.4.3.2.1(the finished pane shall not be larger than a prescribed rectangle of dimensions (W + v, L + v), or smaller than a prescribed rectangle of dimensions (W – v, L – v), where v is the maximum tolerance on nominal dimensions. The corresponding sides of the prescribed rectangles shall be parallel to each other and these rectangles shall have a common centre (see Fig.1).) |
- |
5800.00 |
|
- |
| Cl.4.3.2.2(The length and width of the glass on cut sizes shall be measured with a steel scale (tape) which is graduated to 1 mm. The measurement shall be made on adjacent two sides. The tolerances on nominal dimensions length L, and width W, shall be ± 5mm.) |
- |
5800.00 |
|
- |
| Cl.4.3.3(The tolerances on diagonals shall be as specified in Table 3.) |
- |
5800.00 |
|
- |
| Cl.4.4 (Annex C Table 8)(The glass shall be viewed under the conditions of observation as described in Annex C, and the angle at which there is no optical distortion shall be noted. This angle shall not be less than the appropriate critical viewing angle (see Table 8).) |
- |
16200.00 |
|
- |
| Cl.4.5.1(see Table 4(Spot faults are categorized based on their size (see Table 4). Determination of spot faults shall be done in accordance with Annex D. The maximum permissible number of the different categories of spot faults shall be as per Tables 5 and 6.) |
- |
16200.00 |
|
- |
| Cl.4.5.2(Annexure E)(There shall be no reams, strings and lines distinguished visually when tested in accordance with Annex E.) |
- |
16200.00 |
|
- |
| 4.3.1(Thickness) |
- |
5125.00 |
|
- |
| 4.3.1(Thickness test) |
- |
5125.00 |
|
- |
| 4.3.1(Thickness test) |
- |
5125.00 |
|
- |
|
13 Nov, 2028 |
- - |
| 3 |
IS 18648 (2024) |
Classification and Performance Requirements for Doors Windows and Sliders - Specification |
Classification and Performance Requirements for Doors, Windows and Sliders |
789500.00 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| As per Clause 7.3(Doors, Windows and Sliders) |
- |
78750.00 |
|
- |
| As per Clause 7.3(Doors, Windows and Sliders) |
- |
78750.00 |
|
- |
| As per Clause 7.4.2(Doors, Windows and Sliders) |
- |
78750.00 |
|
- |
| As per Clause 7.4.3(Doors, Windows and Sliders) |
- |
78750.00 |
|
- |
| As per Clause 7.4.4(Doors, Windows and Sliders) |
- |
78750.00 |
|
- |
| As per Clause 7.5(Doors, Windows and Sliders) |
- |
383250.00 |
|
- |
| As per Clause 6.1.6(Doors, Windows and Sliders) |
- |
12500 |
|
- |
|
13 Nov, 2028 |
- For grade O only |
| 4 |
IS 17346 (2020) |
Insulating Glazing Unit ” Specification |
Insulting Glazing Unit |
10325.00 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 5.1.2(Thickness test) |
- |
5125.00 |
|
Testing Charges for Thickness Test |
| 5.1.1(Dimension and Squarenes test) |
- |
5200.00 |
|
Combined Testing Charges for Dimension and Squareness |
|
13 Nov, 2028 |
- a) 5.2.1 - Dew/Frost Point Measurement
b) 5.2.2 - Climate Test (Optional)
c) Inert Gas Level Test (Optional) |
| 5 |
IS 2553 : Part 1 (2018) |
Safety glass - Specification: Part 1 architectural, building and general uses (Fourth Revision) |
Toughened Glass |
66100.00 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 5.2.1 (Thickness -IS 17004 & IS 14900) |
- |
5125.00 |
|
Testing Charges for Thickness Measurement |
| 5.2.2.1( Dimensions- Width ) |
- |
5200.00 |
|
Testing Charges for Dimensions - width measurement |
| 5.2.2.1( Dimensions- Length) |
- |
5200.00 |
|
Testing Charges for Dimensions - length measurement |
| 5.2.2.2( Squareness) |
- |
5200.00 |
|
Combined Testing Charges for Dimension and Squareness |
| 5.2.3 (Fragmentation Test- IS 17004) |
- |
6150.00 |
|
Testing Charges for Fragmentation Test |
| 5.2.4-a( Flatness-Overall bow-IS 17004) |
- |
6350.00 |
|
Combined Testing Charges for Flatness test |
| 5.2.4-b( Flatness-Roller wave distortion-IS 17005) |
- |
6550.00 |
|
Combined Testing Charges for Flatness test |
| 5.2.4-c( Flatness-Edge lift-IS 17006) |
- |
6550.00 |
|
Combined Testing Charges for Flatness test |
| 5.2.4-d( Flatness-Local distortion-IS 17007) |
- |
6550.00 |
|
Combined Testing Charges for Flatness test |
| 5.2.6( Surface Compression (Optional)- IS 17004) |
- |
6825.00 |
|
Testing Charges for Surface Compression Test |
| 5.1.1(General) |
- |
1200 |
|
- |
| 5.2.7(Four point bending) |
- |
5200 |
|
- |
|
13 Nov, 2028 |
- - |
| 6 |
IS 16982 (2018) |
Heat strengthened glass - Specification |
Heat Strengthened Glass |
49300.00 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4.3(Thickness test) |
- |
5125.00 |
|
Testing Charges for Thickness Measurement |
| 4.4(Dimension and Squarenes test) |
- |
5200.00 |
|
Combined Testing Charges for Dimension and Squareness |
| 4.7(Overall Bow) |
- |
6350.00 |
|
Combined Testing Charges for Flatness test |
| 4.7(measurement of wave and roller wave) |
- |
6550.00 |
|
Combined Testing Charges for Flatness test |
| 4.7(Edge lift test) |
- |
655.00 |
|
Combined Testing Charges for Flatness test |
| 4.7(Local distortion test) |
- |
6550.00 |
|
Combined Testing Charges for Flatness test |
| 4.5(Fragmentation test) |
- |
6150.00 |
|
Testing Charges for Fragmentation Test |
| 4.5(Surface compression) |
- |
6825.00 |
|
Testing Charges for Surface Compression Test |
|
13 Nov, 2028 |
- a) 4.2 - Distribution of Allowable Defects
b) 4.6 - Mechanical Strength (Optional Test) |