1 |
IS 1554 : Part 1 (1988) |
Specification for pvc insulated (Heavy Duty) electric cables: Part 1 for working voltages up to and including 1100 v (Third Revision) |
- |
-
|
27400 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
3.1(MATERIALS : CONDUCTOR) |
- |
0 |
|
- |
4.1.1(INSULATION : General Purjose Insulaiion) |
- |
0 |
|
- |
4.1.2(INSULATION : Heat Resisting Insulation) |
- |
0 |
|
- |
5.1(MATERIALS : FILLER AND INNER SHEATH) |
- |
0 |
|
- |
5.2(MATERIALS : FILLER AND INNER SHEATH) |
- |
0 |
|
- |
6.1(MATERIALS : ARMGURING) |
- |
0 |
|
- |
6.2(MATERIALS : ARMGURING) |
- |
0 |
|
- |
7.1.1(OUTER SHEATH : For Cables with General Purpose InsuIafion) |
- |
0 |
|
- |
7.1.2(OUTER SHEATH : For Cables with Heat Resisting InsuIalion) |
- |
0 |
|
- |
8.1(CONSTRUCTION : CONDUCTOR) |
- |
0 |
|
- |
8.2(CONSTRUCTION : CONDUCTOR) |
- |
0 |
|
- |
9.1(INSULATION ) |
- |
0 |
|
- |
9.2(INSULATION : Thickness of Insulation) |
- |
200 |
|
- |
9.3(INSULATION :Tolerance on Thickness of Insulation) |
- |
0 |
|
- |
9.4(INSULATION : Application of Insulation) |
- |
0 |
|
- |
10.1(CORE IDENTIFICATION) |
- |
0 |
|
- |
10.2(CORE IDENTIFICATION) |
- |
0 |
|
- |
10.3(CORE IDENTIFICATION) |
- |
0 |
|
- |
10.3.1(Arrangement of Marking) |
- |
0 |
|
- |
11.1(LAYING UP OF CORES) |
- |
0 |
|
- |
11.2(LAYING UP OF CORES) |
- |
0 |
|
- |
12.1(INNER SHEATH) |
- |
0 |
|
- |
12.2(INNER SHEATH) |
- |
0 |
|
- |
12.3(INNER SHEATH :Thickness of Inner Sheath) |
- |
150 |
|
- |
12.3.1(INNER SHEATH :Thickness of Inner Sheath) |
- |
0 |
|
- |
13.1.1(ARMOURING : Application) |
- |
0 |
|
- |
13.1.2(Armouring: Coverage ) |
- |
200 |
|
- |
13.1.3(ARMOURING : Direction of lay ) |
- |
0 |
|
- |
13.1.4(ARMOURING : Application) |
- |
0 |
|
- |
13.2(ARMOURING : Type of Armour) |
- |
0 |
|
- |
13.2.1(ARMOURING : Type of Armour) |
- |
0 |
|
- |
13.3(Armouring : Dimensions -Wire Diameter) |
- |
200 |
|
- |
13.3(Armouring : Dimensions -Formed wire ) |
- |
200 |
|
- |
13.4(ARMOURING : Joints) |
- |
0 |
|
- |
13.5.1(ARMOURING : Resistance) |
- |
200 |
|
- |
13.5.2(ARMOURING : Resistance) |
- |
0 |
|
- |
13.6 a)(ARMOURING: Tensile Strength) |
- |
100 |
|
- |
13.6 b)(ARMOURING: Elongation ) |
- |
100 |
|
- |
13.6 c)(ARMOURING: Torsion Test (For round wire ) ) |
- |
200 |
|
- |
13.6 d)(ARMOURING: Winding Test(For formed wire)) |
- |
100 |
|
- |
13.6 e)(ARMOURING: Uniformity of zinc coating) |
- |
100 |
|
- |
13.6 f)(ARMOURING: Mass of zinc coating ) |
- |
200 |
|
- |
13.6 g)(ARMOURING: Resistivity) |
- |
100 |
|
- |
14.1(OUTER SHEATH) |
- |
0 |
|
- |
14.2(OUTER SHEATH) |
- |
0 |
|
- |
14.3(OUTER SHEATH : Colour ) |
- |
15 |
|
- |
14.4.1(Thickness of Outer Sheath : Unarmowed Cables) |
- |
150 |
|
- |
14.4.2(Thickness of Outer Sheath : Armoured Cables) |
- |
150 |
|
- |
15.1 a) 1)(Tests on conductor : Annealing test ( for copper )) |
- |
500 |
|
- |
15.1 a) 2)(Tensile test (for aluminium) - Before stranding ) |
- |
200 |
|
- |
15.1 a) 2)(Tensile test (for aluminium) - After stranding ) |
- |
200 |
|
- |
15.1 a) 3)(Tests on conductor : Wrapping test ( for aluminium )) |
- |
100 |
|
- |
15.1 a) 4)(Tests on conductor : Conductor resistance test) |
- |
700 |
|
- |
15.1 a) 4)(Resistance test - Neutral conductor ) |
- |
0 |
|
- |
15.1 d)1)(Phyaical tests for insulation : Tensile Test) |
- |
500 |
|
- |
15.1 d)1)(Phyaical tests for insulation : Elongation ) |
- |
500 |
|
- |
15.1 d)1)(Physical tests for sheath : Tensile stregth ) |
- |
500 |
|
- |
15.1 d)1)(Physical tests for sheath : Elongation ) |
- |
500 |
|
- |
15.1 d)2)(Phyaical tests for insulation- Ageing in air Oven : Tensile Test) |
- |
1000 |
|
- |
15.1 d)2)(Phyaical tests for insulation - Ageing in air oven : Elongation ) |
- |
1000 |
|
- |
15.1 d)2)(Phyaical tests for insulation - Ageing in air Oven : Tensile Variation ) |
- |
0 |
|
- |
15.1 d)2)(Phyaical tests for insulation- Ageing in air oven : Elongation Variation ) |
- |
0 |
|
- |
15.1 d)2)(Physical tests for outer sheath- Ageing in air oven : Tensile stregth ) |
- |
1000 |
|
- |
15.1 d)2)(Physical tests for outer sheath -Ageing in air oven : Elongation ) |
- |
1000 |
|
- |
15.1 d)2)(Physical tests for outer sheath- Ageing in air oven : Tensile stregth Variation ) |
- |
0 |
|
- |
15.1 d)2)(Physical tests for outer sheath -Ageing in air oven : Elongation Variation ) |
- |
0 |
|
- |
15.1 d)3)(Phyaical tests for insulation : Shrinkage ) |
- |
150 |
|
- |
15.1 d)3)(Phyaical tests for insulation : Shrinkage - Crack observed ) |
- |
0 |
|
- |
15.1 d)3)(Phyaical tests for Sheath : Shrinkage ) |
- |
150 |
|
- |
15.1 d)3)(Phyaical tests for Sheath : Shrinkage - Crack observed ) |
- |
0 |
|
- |
15.1 d)4)(Hot deformation : Insulation ) |
- |
150 |
|
- |
15.1 d)4)(Hot deformation : Sheath ) |
- |
150 |
|
- |
15.1 d)5)( Loss of mass in air oven- Insulation ) |
- |
800 |
|
- |
15.1 d)5)( Loss of mass in air oven- sheath ) |
- |
800 |
|
- |
15.1 d)6)(Heat shock test- Insulation ) |
- |
150 |
|
- |
15.1 d)6)(Heat shock test- sheath ) |
- |
150 |
|
- |
15.1 d)7)(Thermal stability- insulation ) |
- |
150 |
|
- |
15.1 d)7)(Thermal stability- Sheath ) |
- |
150 |
|
- |
15.1 e)(Insulation resistance test : Volume Resistivity ) |
- |
250 |
|
- |
15.1 e)(Insulation resistance test : IR Constant ) |
- |
250 |
|
- |
15.1 f)(High voltage test ( water immersion test )) |
- |
500 |
|
- |
15.1 g)(High voltage test at room temperature) |
- |
500 |
|
- |
15.4 a)(Cold bend test- Insulation ( Optional test)) |
- |
600 |
|
- |
15.4 a)(Cold bend test- Sheath ( Optional test)) |
- |
600 |
|
- |
15.4 b)(Cold impact test- Insulation ( Optional test)) |
- |
600 |
|
- |
15.4 b)(Cold impact test- Sheath ( Optional test)) |
- |
600 |
|
- |
15.4 c)(Armour resistance test ( for other than mining cables ).- Optional test ) |
- |
200 |
|
- |
16.1(DETAILS OF TESTS : General) |
- |
0 |
|
- |
16.2(DETAILS OF TESTS : High Voltage Test at Room Temperature) |
- |
0 |
|
- |
16.3.1(High Voltage Test ( Water Immersion Test ) : a.c. Test) |
- |
500 |
|
- |
16.3.2(High Voltage Test ( Water Immersion Test ) : d.c. Test) |
- |
500 |
|
- |
16.4(Flammability Test) |
- |
2000 |
|
- |
16.5(Oxygen Index Test) |
- |
1000 |
|
- |
16.6(Flame Retardance Test on Single Cables) |
- |
2000 |
|
- |
16.7(Flame Retardance Test on Bunched Cables) |
- |
6000 |
|
- |
16.9(Test for Halogen Acid Gas Evolution) |
- |
1000 |
|
- |
16.1(Temperature Index) |
- |
1000 |
|
- |
17.1(IDENTIFICATION : Manufacturer’s Identification) |
- |
0 |
|
- |
17.2(IDENTIFICATION : Cable Identification) |
- |
0 |
|
- |
17.2.1(IDENTIFICATION : Cable Identification) |
- |
0 |
|
- |
17.3(IDENTIFICATION : Cable Code) |
- |
0 |
|
- |
15.1.e(Insulation resistance Test- Insulation resistance At Maximum rated temperature temperature) |
- |
250 |
|
- |
15.1.e(Insulation resistance Test- Insulation resistance constant At Room temperature) |
- |
250 |
|
- |
15.1.e(Insulation resistance Test- Volume Resistivity At Maximum rated temperature temperature) |
- |
0 |
|
- |
15.1.e(Insulation resistance Test- Volume Resistivity At Room temperature) |
- |
0 |
|
- |
16.4(Flammability Test- Un affected portion) |
- |
0 |
|
- |
16.4(Flammability Test- Period of Burning) |
- |
0 |
|
- |
9.3(Minimum Thickness of Reduce core insulation) |
- |
0 |
|
- |
9.2(Thickness of Reduce core insulation) |
- |
0 |
|
- |
3.1 Table 2
IS 8130(Number of wires in the conductor) |
- |
0 |
|
- |
|
Complete
|
|
16 Aug, 2024 |
- |
2 |
IS 1554 : Part 2 (1988) |
Specification for pvc insulated (Heavy Duty) electric cables: Part 2 for working voltages from 3.3 kV up to and including 11 kV (Second Revision) |
- |
-
|
256700.00 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
3.1(CONDUCTOR) |
- |
0 |
|
- |
3.1.1(CONDUCTOR) |
- |
0 |
|
- |
4.1(INSULATION) |
- |
0 |
|
- |
5.1(SCREENING) |
- |
0 |
|
- |
5.1.1(Non-magnetic Metallic Tape for SingleCore Unscreened and Unarmoured Cables) |
- |
0 |
|
- |
6.1(FILLERS AND INNER SHEATH) |
- |
0 |
|
- |
6.2(FILLERS AND INNER SHEATH) |
- |
0 |
|
- |
7.1(ARMOURING) |
- |
0 |
|
- |
7.2(ARMOURING) |
- |
0 |
|
- |
8.1(OUTER SHEATH) |
- |
0 |
|
- |
9.1(CONDUCTOR) |
- |
0 |
|
- |
9.2(CONDUCTOR) |
- |
0 |
|
- |
10.1(CONDUCTOR SCREENING) |
- |
0 |
|
- |
11.1(INSULATION) |
- |
0 |
|
- |
11.2(INSULATION : Thickness of Insulation) |
- |
1000 |
|
- |
11.3(INSULATION : Tolerance on Thickness of Insulation) |
- |
500 |
|
- |
11.4(INSULATION : Application of Insulation) |
- |
0 |
|
- |
12.1(INSULATION SCREENING) |
- |
0 |
|
- |
12.2(INSULATION SCREENING) |
- |
0 |
|
- |
12.3(INSULATION SCREENING) |
- |
0 |
|
- |
12.4(INSULATION SCREENING) |
- |
0 |
|
- |
13.1(CORE IDENTIFICATION) |
- |
0 |
|
- |
13.1.1(CORE IDENTIFICATION) |
- |
0 |
|
- |
14.1(LAYING UP OF CORES) |
- |
0 |
|
- |
15.1(INNER SHEATH (COMMON COVERING)) |
- |
0 |
|
- |
15.2(INNER SHEATH (COMMON COVERING)) |
- |
0 |
|
- |
15.3(INNER SHEATH (COMMON COVERING)) |
- |
0 |
|
- |
15.4(INNER SHEATH (COMMON COVERING) : Thickness of Inner Sheath) |
- |
300 |
|
- |
15.4.1(INNER SHEATH (COMMON COVERING) : Thickness of Inner Sheath) |
- |
200 |
|
- |
16.1.1(ARMOURING : Application) |
- |
0 |
|
- |
16.1.2(ARMOURING : Application) |
- |
0 |
|
- |
16.1.3(ARMOURING : Direction of lay ) |
- |
0 |
|
- |
16.1.4(ARMOURING : Application) |
- |
0 |
|
- |
16.2.1(ARMOURING : Type of Armour) |
- |
0 |
|
- |
16.2.2(ARMOURING : Type of Armour) |
- |
0 |
|
- |
16.3(Armouring : Dimensions -Wire Diameter) |
- |
500 |
|
- |
16.3(Armouring : Dimensions -Formed wire ) |
- |
500 |
|
- |
16.4(ARMOURING : Joints) |
- |
0 |
|
- |
16.5(ARMOURING : Resistance) |
- |
1000 |
|
- |
13.6 a)(ARMOURING: Tensile Strength) |
- |
500 |
|
- |
13.6 b)(ARMOURING: Elongation ) |
- |
500 |
|
- |
13.6 c)(ARMOURING: Torsion Test (For round wire ) ) |
- |
500 |
|
- |
13.6 d)(ARMOURING: Winding Test(For formed wire)) |
- |
500 |
|
- |
13.6 e)(ARMOURING: Uniformity of zinc coating) |
- |
500 |
|
- |
13.6 f)(ARMOURING: Mass of zinc coating ) |
- |
500 |
|
- |
13.6 g)(ARMOURING: Resistivity) |
- |
500 |
|
- |
17.1(OUTER SHEATH) |
- |
0 |
|
- |
17.2(OUTER SHEATH : colour ) |
- |
0 |
|
- |
17.3.1(Thickness of Outer Sheath : Unarmoured Cables) |
- |
0 |
|
- |
17.3.2(Thickness of Outer Sheath : Armoured Cables) |
- |
0 |
|
- |
18.1 a) 1)(Tests on Conductor : Annealing test (for copper)) |
- |
1900 |
|
700 for annealing test, 1200 for Copper Purity test. |
18.1 a) 2)(Tensile test (for aluminium) - Before stranding ) |
- |
250 |
|
- |
18.1 a) 2)(Tensile test (for aluminium) - After stranding ) |
- |
250 |
|
- |
18.1 a) 3)(Tests on Conductor : Wrapping test ( for aluminium)) |
- |
500 |
|
- |
18.1 a)4)(Tests on conductor : Conductor resistance test - Main conductor ) |
- |
1500 |
|
- |
18.1 a)4)(Resistance test - Neutral conductor ) |
- |
0 |
|
- |
18.1 d) 1)(Phyaical tests for insulation : Tensile Test) |
- |
625 |
|
- |
18.1 d) 1)(Phyaical tests for insulation : Elongation ) |
- |
625 |
|
- |
18.1 d) 1)(Physical tests for sheath : Tensile stregth ) |
- |
625 |
|
- |
18.1 d) 1)(Physical tests for sheath : Elongation ) |
- |
625 |
|
- |
18.1 d) 2)(Phyaical tests for insulation- Ageing in air Oven : Tensile Test) |
- |
1125 |
|
- |
18.1 d) 2)(Phyaical tests for insulation - Ageing in air oven : Elongation ) |
- |
1125 |
|
- |
18.1 d) 2)(Phyaical tests for insulation - Ageing in air Oven : Tensile Variation ) |
- |
250 |
|
- |
18.1 d) 2)(Phyaical tests for insulation- Ageing in air oven : Elongation Variation ) |
- |
250 |
|
- |
18.1 d) 2)(Physical tests for outer sheath- Ageing in air oven : Tensile stregth ) |
- |
1125 |
|
- |
18.1 d) 2)(Physical tests for outer sheath -Ageing in air oven : Elongation ) |
- |
1125 |
|
- |
18.1 d) 2)(Physical tests for outer sheath- Ageing in air oven : Tensile stregth Variation ) |
- |
250 |
|
- |
18.1 d) 2)(Physical tests for outer sheath -Ageing in air oven : Elongation Variation ) |
- |
250 |
|
- |
18.1 d) 3)(Phyaical tests for insulation : Shrinkage ) |
- |
1000 |
|
- |
18.1 d) 3)(Phyaical tests for insulation : Shrinkage - Crack observed ) |
- |
500 |
|
- |
18.1 d) 3)(Phyaical tests for Sheath : Shrinkage ) |
- |
1000 |
|
- |
18.1 d) 3)(Phyaical tests for Sheath : Shrinkage - Crack observed ) |
- |
500 |
|
- |
18.1 d) 4)(Hot deformation : Insulation ) |
- |
2500 |
|
- |
18.1 d) 4)(Hot deformation : Sheath ) |
- |
800 |
|
- |
18.1 d) 5)( Loss of mass in air oven- Insulation ) |
- |
4000 |
|
- |
18.1 d) 5)( Loss of mass in air oven- sheath ) |
- |
1500 |
|
- |
18.1 d) 6)(Heat shock test- Insulation ) |
- |
2500 |
|
- |
18.1 d) 6)(Heat shock test- sheath ) |
- |
1000 |
|
- |
18.1 d) 7)(Thermal stability- insulation ) |
- |
2000 |
|
- |
18.1 d) 7)(Thermal stability- Sheath ) |
- |
1000 |
|
- |
18.1 d) 8)(Water absorption (gravimetric)(for insulation, where applicable)) |
- |
9500 |
|
- |
18.1 e)(Insulation resistance test : Volume Resistivity ) |
- |
1000 |
|
- |
18.1 e)(Insulation resistance test : IR Constant ) |
- |
1500 |
|
- |
19.2(Partial discharge test) |
- |
42500 |
|
- |
19.3(Bending test) |
- |
10000 |
|
- |
19.4(Dielectric power factor test) |
- |
12500 |
|
- |
19.4(Dielectric power factor test) |
- |
12500 |
|
- |
19.5(Heating cycle test) |
- |
42500 |
|
- |
19.6(Impulse withstand test) |
- |
45500 |
|
- |
19.7(High voltage test) |
- |
12500 |
|
- |
19.8(Flammability test) |
- |
3000 |
|
- |
19.9(Oxygen Index Test) |
- |
1500 |
|
- |
19.10(Flame Retardance Test on Single Cables) |
- |
1500 |
|
- |
19.11(Flame Retardance Test on Bunched Cables) |
- |
5000 |
|
- |
19.13(Test for Halogen Acid Gas Evolution) |
- |
3500 |
|
1500 for Halogen Acid Gas Evolution & 2000 for Smoke density test. |
19.14(Temperature Index) |
- |
1500 |
|
- |
18.4(Optional Test : Cold Impact ) |
- |
2500 |
|
- |
20.1(IDENTIFICATION : Manufacturer's Identification) |
- |
0 |
|
- |
20.2(IDENTIFICATION : Cable Identification) |
- |
0 |
|
- |
20.3(IDENTIFICATION : Cable Code) |
- |
0 |
|
- |
|
Complete
|
|
16 Aug, 2024 |
- |
3 |
IS 7098 : Part 1 (1988) |
Specification for crosslinked polyethylene insulated pvc sheathed cables: Part 1 for working voltages up to and including 1100 volts (First Revision) |
- |
-
|
28400 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
3(CONDUCTOR: MATERIALS) |
- |
0 |
|
- |
4(INSULATION : MATERIALS) |
- |
0 |
|
- |
5.1(FILLER AND INNER SHEATH) |
- |
0 |
|
- |
5.2(FILLER AND INNER SHEATH) |
- |
0 |
|
- |
6(ARMOURING) |
- |
0 |
|
- |
7(OUTER SHEATH) |
- |
0 |
|
- |
8.1(CONDUCTOR: CONSTRUCTION) |
- |
0 |
|
- |
8.2(PROTECTIVE BARRIER) |
- |
0 |
|
- |
8.3(SIZE OF NEUTRAL CONDUCTOR) |
- |
0 |
|
- |
9.1(Insulation Applied by extrusicn) |
- |
0 |
|
- |
9.2(Thickness of Insulation - Average) |
- |
200 |
|
- |
9.3(Thickness of Insulation - Minimum) |
- |
0 |
|
- |
9.4(Application of Insulation) |
- |
0 |
|
- |
10.1(Core Identification) |
- |
0 |
|
- |
10.2(Core Identification- Neutral) |
- |
0 |
|
- |
10.3(Core Identification by number ) |
- |
0 |
|
- |
10.4(Core Identification by number - Neutral ) |
- |
0 |
|
- |
11(LAVING UP OF CORES) |
- |
0 |
|
- |
12.1 & 12.2(Inner sheath : Application) |
- |
0 |
|
- |
12.3(Thickness of Inner Sheath) |
- |
100 |
|
- |
13.1(Armouring: Application) |
- |
0 |
|
- |
13.1.2(Armouring: Coverage ) |
- |
100 |
|
- |
13.1.3(Armouring: Direction of Lay ) |
- |
0 |
|
- |
13.2(Type of armour ) |
- |
0 |
|
- |
13.3(Armouring : Dimensions -Wire Diameter) |
- |
500 |
|
- |
13.3(Armouring : Dimensions -Formed wire ) |
- |
500 |
|
- |
13.4(Armour: Joint) |
- |
0 |
|
- |
13.5(Armouring : Resistance Test) |
- |
200 |
|
- |
13.6 a)(ARMOURING: Tensile Strength) |
- |
150 |
|
- |
13.6 b)(ARMOURING: Elongation ) |
- |
150 |
|
- |
13.6 c)(ARMOURING: Torsion Test (For round wire ) ) |
- |
100 |
|
- |
13.6 d)(ARMOURING: Winding Test(For formed wire)) |
- |
100 |
|
- |
13.6 e)(ARMOURING: Uniformity of zinc coating) |
- |
150 |
|
- |
13.6 f)(ARMOURING: Mass of zinc coating ) |
- |
150 |
|
- |
13.6 g)(ARMOURING: Resistivity) |
- |
100 |
|
- |
14.1(Outer Sheath : Application) |
- |
0 |
|
- |
14.2(Colour of outer sheath) |
- |
0 |
|
- |
14.3(Thickness of outer sheath - AVERAGE) |
- |
200 |
|
- |
14.3(Thickness of outer sheath - minimum) |
- |
0 |
|
- |
15.1 a) i)(Annealing Test ( For copper wire ) ) |
- |
1000 |
|
- |
15.1 a) ii)(Tensile test (for aluminium) - Before stranding ) |
- |
400 |
|
- |
15.1 a) ii)(Tensile test (for aluminium) - After stranding ) |
- |
400 |
|
- |
15.1 a) iii)(Wrapping test (for aluminium)) |
- |
200 |
|
- |
15.1 a) iv)(Resistance test - Main conductor) |
- |
500 |
|
- |
15.1 a) iv)(Resistance test - Neutral conductor) |
- |
500 |
|
- |
15.1 d) i) (Phyaical tests for insulation : Tensile Test) |
- |
250 |
|
- |
15.1 d) i) (Phyaical tests for insulation : Elongation) |
- |
250 |
|
- |
15.1 d) ii) (Phyaical tests for insulation - Ageing in air Oven : Tensile Variation ) |
- |
500 |
|
- |
15.1 d) ii) (Phyaical tests for insulation- Ageing in air oven : Elongation Variation ) |
- |
500 |
|
- |
15.1 d) iii) (Phyaical tests for insulation : Hot set ) |
- |
150 |
|
- |
15.1 d) iii) (Phyaical tests for insulation : Permanent set ) |
- |
100 |
|
- |
15.1 d) iv) (Phyaical tests for insulation : Shrinkage ) |
- |
150 |
|
- |
15.1 d) iv) (Phyaical tests for insulation : Shrinkage - Crack observed ) |
- |
100 |
|
- |
15.1 d) v) (Insulation: Waterabsorption(gravimetric)) |
- |
500 |
|
- |
15.1 e) i) (Physical tests for outer sheath : Tensile stregth) |
- |
250 |
|
- |
15.1 e) i) (Physical tests for outer sheath : Elongation) |
- |
250 |
|
- |
15.1 e) ii) (Physical tests for outer sheath- Ageing in air oven : Tensile stregth ) |
- |
500 |
|
- |
15.1 e) ii) (Physical tests for outer sheath -Ageing in air oven : Elongation ) |
- |
500 |
|
- |
15.1 e) ii) (Physical tests for outer sheath- Ageing in air oven : Tensile stregth Variation ) |
- |
0 |
|
- |
15.1 e) ii) (Physical tests for outer sheath -Ageing in air oven : Elongation Variation ) |
- |
0 |
|
- |
15.1 e) iii) (Sheath: Loss of mass in air oven) |
- |
1000 |
|
- |
15.1 e) iv) (Phyaical tests for Sheath : Shrinkage ) |
- |
150 |
|
- |
15.1 e) iv) (Phyaical tests for Sheath : Shrinkage - Crack observed ) |
- |
100 |
|
- |
15.1 e) v) (Sheath : Hot deformation) |
- |
500 |
|
- |
15.1 e) vi) (Sheath : Heat shock test) |
- |
250 |
|
- |
15.1 e) vii) (Sheath : Thermalstability) |
- |
500 |
|
- |
15.1 f)(INSULATION RESISTANCE TEST : Volume resistivity ) |
- |
500 |
|
- |
16.2(HIGH VOLTAGE TEST ) |
- |
500 |
|
- |
16.3(FLAMMABILITY TEST : Period of Burning ) |
- |
500 |
|
- |
16.3(FLAMMABILITY TEST : Unaffected length ) |
- |
500 |
|
- |
16.9(Oxygen Index Test) |
- |
1000 |
|
- |
16.1(Flame Retardance Test on Single Cables) |
- |
1000 |
|
- |
16.11(Flame Retardance Test on Bunched Cables) |
- |
6000 |
|
- |
16.13(Test for Halogen Acid Gas Evolution) |
- |
1000 |
|
- |
16.14(Temperature Index) |
- |
1000 |
|
- |
17.1(Manufacturer'. identification) |
- |
0 |
|
- |
17.2(cable Indentification ) |
- |
0 |
|
- |
17.3(cable Code ) |
- |
0 |
|
- |
|
Complete
|
|
16 Aug, 2024 |
- |
4 |
IS 7098 : Part 2 (2011) |
Crosslinked polyethylene insulated thermoplastic sheathed cables - Specification: Part 2 for working voltages from 3.3 kV up to and including 33 kV (Second Revision) |
- |
-
|
254200 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
4.1(CONDUCTOR) |
- |
0 |
|
- |
4.1.1(CONDUCTOR) |
- |
0 |
|
- |
5(INSULATION) |
- |
0 |
|
- |
6(SCREENING) |
- |
0 |
|
- |
6.1.1(SCREENING : - Non-metallic — Semiconducting Compound) |
- |
0 |
|
- |
6.1.2(SCREENING : - Non-magnetic Metallic Tape for Single Core Unscreened and Unarmoured Cables) |
- |
0 |
|
- |
7(FILLERS AND INNER SHEATH) |
- |
0 |
|
- |
8.1(ARMOURING) |
- |
0 |
|
- |
8.2(ARMOURING) |
- |
0 |
|
- |
9(OUTER SHEATH ) |
- |
0 |
|
- |
10.1(CONDUCTOR) |
- |
0 |
|
- |
10.2(CONDUCTOR) |
- |
0 |
|
- |
11(CONDUCTOR SCREENING) |
- |
0 |
|
- |
12.1(INSULATION) |
- |
0 |
|
- |
12.2(INSULATION : Thickness of Insulation) |
- |
1000 |
|
- |
12.3(INSULATION : Tolerance on Thickness of Insulation) |
- |
500 |
|
- |
12.4(Eccentricity and Ovality) |
- |
1000 |
|
- |
12.5(INSULATION : Application of Insulation) |
- |
0 |
|
- |
13.1(INSULATION SCREENING) |
- |
0 |
|
- |
13.2(INSULATION SCREENING) |
- |
0 |
|
- |
13.3(INSULATION SCREENING) |
- |
0 |
|
- |
13.4(INSULATION SCREENING) |
- |
0 |
|
- |
14.1(CORE IDENTIFICATION) |
- |
0 |
|
- |
14.1.1(CORE IDENTIFICATION) |
- |
0 |
|
- |
15.1(LAVING UP OF CORES) |
- |
0 |
|
- |
16.1(INNER SHEATH (COMMON COVERING)) |
- |
0 |
|
- |
16.2(INNER SHEATH (COMMON COVERING)) |
- |
0 |
|
- |
16.2.1(INNER SHEATH (COMMON COVERING)) |
- |
0 |
|
- |
16.3(INNER SHEATH (COMMON COVERING) : Thickness of Inner Sheath) |
- |
0 |
|
- |
16.3.1(INNER SHEATH (COMMON COVERING) : Thickness of Inner Sheath) |
- |
500 |
|
- |
17.1(ARMOURING : Application ) |
- |
0 |
|
- |
17.1.1(ARMOURING ) |
- |
0 |
|
- |
17.1.2(ARMOURING ) |
- |
0 |
|
- |
17.1.3(ARMOURING ) |
- |
0 |
|
- |
17.2(ARMOURING : Type of armour ) |
- |
0 |
|
- |
17.2.1(ARMOURING : Type of armour ) |
- |
0 |
|
- |
17.2(ARMOURING : Coverage ) |
- |
500 |
|
- |
17.3(ARMOURING : Dimension ) |
- |
500 |
|
- |
17.4(ARMOURING : Joints) |
- |
0 |
|
- |
16.4(ARMOURING : Resistance) |
- |
1500 |
|
Tensile strength and Elongation at break, Torsion test for round wires, Winding test for formed wires, Uniformity of zinc coating, Mass of zinc coating and Resistivity of armour. |
18.1(OUTER SHEATH) |
- |
0 |
|
- |
18.2(OUTER SHEATH: Colour) |
- |
0 |
|
- |
18.3(Thicknes of outer sheath : average ) |
- |
300 |
|
- |
18.3(Thicknes of outer sheath : minimum ) |
- |
200 |
|
- |
19.1 i) a)(Annealing test (for copper)) |
- |
1900 |
|
700 for Annealing test, 1200 for Copper purity test. |
19.1 i) b)(Tensile test (for aluminium) - Before stranding ) |
- |
200 |
|
- |
19.1 i) b)(Tensile test (for aluminium) - After stranding ) |
- |
200 |
|
- |
19.1 i) c)(Wrapping test ( for aluminium)) |
- |
300 |
|
- |
19.1 i) d)(Resistance test - Main conductor ) |
- |
500 |
|
- |
19.1 i) d)(Resistance test - Neutral conductor ) |
- |
0 |
|
- |
19.1 iii) a)(Phyaical tests for insulation : Tensile Test) |
- |
1250 |
|
- |
19.1 iii) a)(Phyaical tests for insulation : Elongation ) |
- |
1250 |
|
- |
19.1 iii) b)(Phyaical tests for insulation - Ageing in air Oven : Tensile Variation ) |
- |
2500 |
|
- |
19.1 iii) b)(Phyaical tests for insulation- Ageing in air oven : Elongation Variation ) |
- |
2500 |
|
- |
19.1 iii) c)(Degree of cross linking ) |
- |
0 |
|
- |
19.1 iii) d)(Phyaical tests for insulation : Hot set ) |
- |
2000 |
|
- |
19.1 iii) d)(Phyaical tests for insulation : Permanent set ) |
- |
1000 |
|
- |
19.1 iii) e)(Phyaical tests for insulation : Shrinkage ) |
- |
2000 |
|
- |
19.1 iii) e)(Phyaical tests for insulation : Shrinkage - Crack observed ) |
- |
500 |
|
- |
19.1 iii) f)(Insulation: Waterabsorption(gravimetric)) |
- |
5500 |
|
- |
19.1 v) a)(Test for strippability of semiconducting strippable insulation screen
(when applicable)) |
- |
1000 |
|
- |
19.1 v) b)(Volume resistivity) |
- |
4500 |
|
- |
19.1 vi) a)(Physical tests for outer sheath : Tensile stregth ) |
- |
1000 |
|
- |
19.1 vi) a)(Physical tests for outer sheath : Elongation ) |
- |
1000 |
|
- |
19.1 vi) b)(Physical tests for outer sheath- Ageing in air oven : Tensile stregth ) |
- |
2000 |
|
- |
19.1 vi) b)(Physical tests for outer sheath -Ageing in air oven : Elongation ) |
- |
2000 |
|
- |
19.1 vi) b)(Physical tests for outer sheath- Ageing in air oven : Tensile stregth Variation ) |
- |
500 |
|
- |
19.1 vi) b)(Physical tests for outer sheath -Ageing in air oven : Elongation Variation ) |
- |
500 |
|
- |
19.1 vi) c)(Phyaical tests for Sheath : Shrinkage ) |
- |
700 |
|
- |
19.1 vi) c)(Phyaical tests for Sheath : Shrinkage - Crack observed ) |
- |
500 |
|
- |
19.1 vi) d)(Sheath : Hot deformation) |
- |
1600 |
|
- |
19.1 vi) e)(Loss of massIn air oven) |
- |
5000 |
|
- |
19.1 vi) f)(Sheath : Heat shock test) |
- |
2000 |
|
- |
19.1 vi) g)(Sheath : Thermalstability) |
- |
1000 |
|
- |
19.1 vi) h)(Carbon black content of polythene
sheath ) |
- |
3500 |
|
- |
19.1 vii)(Thermal ageing test for complete cable - Tensile stregth ) |
- |
2000 |
|
- |
19.1 vii)(Thermal ageing test for complete cable- Elogation ) |
- |
2000 |
|
- |
19.1 vii)(Thermal ageing test for complete cable- Resistivity ) |
- |
1000 |
|
- |
19.1 xi)(Insulation resistance test : volume resistivity ) |
- |
2500 |
|
- |
20.2(Partial discharge test) |
- |
45000 |
|
- |
20.3(Bending test) |
- |
7500 |
|
- |
20.4(Dielectric power factor test : As a function of voltage) |
- |
12500 |
|
- |
20.4(Dielectric power factor test : As a function of temperature) |
- |
12500 |
|
- |
20.5(Heating Cycle Test) |
- |
42500 |
|
- |
20.6(Impulse withstand test
(Rated voltage, kV 3.8/6.6
Impulse voltage, kV 60)) |
- |
45500 |
|
- |
20.7(High voltage test) |
- |
11500 |
|
- |
20.8(Flammability test) |
- |
3000 |
|
- |
20.1(Oxygen Index Test) |
- |
1500 |
|
- |
20.11(Flame Retardance Test on Single Cables) |
- |
1500 |
|
- |
20.12(Flame Retardance Test on Bunched Cables) |
- |
5000 |
|
- |
20.13(Test for Halogen Acid Gas Evolution) |
- |
1500 |
|
- |
20.14( Test for Smoke Density) |
- |
2000 |
|
- |
20.15(Temperature Index) |
- |
1500 |
|
- |
21.1(IDENTIFICATION : Manufacturer's Identification) |
- |
0 |
|
- |
21.2(IDENTIFICATION : Cable Identification) |
- |
0 |
|
- |
21.3(IDENTIFICATION : Cable Code) |
- |
0 |
|
- |
|
Complete
|
|
16 Aug, 2024 |
- |
5 |
IS 7098 : Part 3 (1993) |
Cross - Linked polyethylene insulated thermoplastic sheathed cables - Specification: Part 3 for working voltages from 66 kV up to and including 220 kV |
- |
-
|
395000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
4.1(CONDUCTOR) |
- |
0 |
|
- |
5(INSULATION) |
- |
0 |
|
- |
6(SCREENING) |
- |
0 |
|
- |
7.1(MOISTURE BARRIER : Laminated Tape) |
- |
0 |
|
- |
7.2(MOISTURE BARRIER : Lead Alloy Sheath) |
- |
0 |
|
- |
8.1(INNER SHEATH) |
- |
0 |
|
- |
8.2(INNER SHEATH) |
- |
0 |
|
- |
8.3(INNER SHEATH) |
- |
0 |
|
- |
9.1(ARMOUR) |
- |
0 |
|
- |
9.2(ARMOUR) |
- |
0 |
|
- |
10.1(OUTER SHEATH) |
- |
0 |
|
- |
10.2(OUTER SHEATH) |
- |
0 |
|
- |
11.1(CONDUCTOR) |
- |
0 |
|
- |
11.2(CONDUCTOR) |
- |
0 |
|
- |
12.1(CONDUCTOR SCREENING ) |
- |
0 |
|
- |
12.2(CONDUCTOR SCREENING ) |
- |
0 |
|
- |
13.1(INSULATION) |
- |
0 |
|
- |
13.2(INSULATION) |
- |
0 |
|
- |
14.1(INSULATION SCREENING) |
- |
0 |
|
- |
14.2.1(INSULATION SCREENING : Non-metallic Part) |
- |
0 |
|
- |
14.2.2(INSULATION SCREENING : Non-metallic Part) |
- |
0 |
|
- |
14.2.3(INSULATION SCREENING : Non-metallic Part) |
- |
0 |
|
- |
14.3.1(INSULATION SCREENING : Metallic Part) |
- |
0 |
|
- |
14.3.2(INSULATION SCREENING : Metallic Part) |
- |
0 |
|
- |
14.3.3(INSULATION SCREENING : Metallic Part) |
- |
0 |
|
- |
15.1(MOISTURE BARRIER) |
- |
0 |
|
- |
15.2.1(Metallic Sheath) |
- |
0 |
|
- |
15.2.2(Metallic Sheath) |
- |
0 |
|
- |
16.1(INNER SHEATH) |
- |
0 |
|
- |
16.2(INNER SHEATH) |
- |
0 |
|
- |
17.1(ARMOUR) |
- |
0 |
|
- |
17.2(ARMOUR) |
- |
0 |
|
- |
17.3(ARMOUR) |
- |
0 |
|
- |
17.4(ARMOUR) |
- |
0 |
|
- |
17.5(ARMOUR) |
- |
0 |
|
- |
18.1(OUTER SHEATH) |
- |
0 |
|
- |
18.2(outer sheath colour) |
- |
0 |
|
- |
18.3.1(Thickness of Outer Sheath : Unarmoured Cables) |
- |
500 |
|
- |
18.3.1(Thickness of Outer Sheath : armoured Cables) |
- |
500 |
|
- |
19.1 A) I)(Tests on conductor : Annealing test ( for copper )) |
- |
750 |
|
- |
19.1 A) II)(Tests on conductor : Resistance test) |
- |
10000 |
|
- |
19.1 b) I)(Test for thickness and dimensions of insulation) |
- |
5000 |
|
- |
19.1 b) II)(Tensile strength and elongation at break) |
- |
5000 |
|
- |
19.1 b) III)(Thermal ageing in air oven) |
- |
10000 |
|
- |
19.1 b) IV)(Hot set test) |
- |
7500 |
|
- |
19.1 b) V)(Shrinkage test) |
- |
2500 |
|
- |
20.3(Test for concentric metallic screen : Test for concentric copper wire) |
- |
5000 |
|
- |
20.4(Test for concentric copper tape) |
- |
5000 |
|
- |
20.5(Thickness of metallic sheath) |
- |
1000 |
|
- |
20.6(Tests for armouring material : Dimensions) |
- |
1000 |
|
- |
19.1 f) II)(Tests for armouring material : Tensile strength and elongation at break) |
- |
2000 |
|
- |
Table 9, (Measurement of thickness) |
- |
500 |
|
- |
19.1 g)2) i)(PVC sheath : Tensile strength and elongation at break) |
- |
2000 |
|
- |
19.1 g)2) iii)(PVC sheath : Loss of mass) |
- |
4000 |
|
- |
19.1 g)2) v)(PVC sheath : Hot deformation test) |
- |
2000 |
|
- |
19.1 g)2) vi)(PVC sheath : Shrinkage test) |
- |
2500 |
|
- |
19.1 g)2) vii)(PVC sheath : Thermal stability) |
- |
1500 |
|
- |
19.1 g)3) ii)(PE sheath : Tensile strength and elongation at break before and after ageing) |
- |
5000 |
|
- |
19.1 g)3) iii)(PE sheath : Hot-detormation) |
- |
2500 |
|
- |
20.7(Flammabihty test ( for PVC outer
sheathed cables only )) |
- |
3000 |
|
- |
20.8.3(Water tightness test) |
- |
45000 |
|
- |
20.9.1(Thermal ageing on complete cable sample) |
- |
10000 |
|
- |
19.1 k) ii)(Tensile strength and elongation at breakfor insulation and outer sheath) |
- |
5000 |
|
- |
20.2(Resistivity test for semi-conducting layer) |
- |
5000 |
|
- |
20.11.1(Bending test followed by P D test) |
- |
50000 |
|
- |
20.12, 20.18(Dielectric power factor and capacitance measurement at ambient temperature) |
- |
15000 |
|
- |
20.13(Dielectric power factor measurement at elevated temperature) |
- |
15000 |
|
- |
20.14.1(Load cycle test followed by P.D measurement) |
- |
75000 |
|
- |
20.15(Impulse Voltage Test Followed by High Voltage Test) |
- |
75000 |
|
- |
19.5(Check on Insulation Thickness Before the Electrical Type Tests) |
- |
0 |
|
- |
20.16.1(Test for Dimensions of Insulation : Insulation Thickness) |
- |
0 |
|
- |
20.16.2(Test for Dimensions of Insulation : Test for Eccentricity) |
- |
0 |
|
- |
20.16.3(Test for Dimensions of Insulation : Test for Ovality) |
- |
0 |
|
- |
20.17(High Voltage Test ( as Routine and
Acceptance Tests ) ) |
- |
10000 |
|
- |
20.18(Measurement of Capacitance) |
- |
5000 |
|
- |
|
Complete
|
|
16 Aug, 2024 |
- |
6 |
IS 8783 : Part 4 : Sec 1 (1995) |
Winding wires for submersible motors - Specification: Part 4 specification for indmdual wires: Sec 1 HR PVC insulated wires (First Revision) |
- |
-
|
13800 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Cl.3.1 (Conductor) |
- |
0 |
|
- |
Cl.4(Material) |
- |
0 |
|
- |
Cl.5.1.1 (Dimensions) |
- |
500 |
|
- |
Cl. 6(Annealing Test) |
- |
700 |
|
- |
Cl 6(Resistance Test) |
- |
1000 |
|
- |
Cl 4.1.2 (Visual examination) |
- |
0 |
|
- |
Cl.3.2(Dielectric Material ) |
- |
0 |
|
- |
Cl. 4 Table 1of IS: 8783 (part 2) (Volume resistivity) |
- |
1200 |
|
- |
Cl. 4 Table 1of IS: 8783 (part 2) (Volume resistivity) |
- |
1200 |
|
- |
Cl. 4 Table 1of IS: 8783 (part 2) (Tensile strength ) |
- |
500 |
|
- |
Cl. 4 Table 1of IS: 8783 (part 2) (Elongation) |
- |
500 |
|
- |
Cl. 4 Table 1of IS: 8783 (part 2) (Tensile Strength) |
- |
1000 |
|
- |
Cl. 4 Table 1of IS: 8783 (part 2) (Variation) |
- |
0 |
|
- |
Cl. 4 Table 1of IS: 8783 (part 2) (Elongation at Break ) |
- |
1000 |
|
- |
Cl. 4 Table 1of IS: 8783 (part 2) (Variation) |
- |
0 |
|
- |
Cl. 4 Table 1of IS: 8783 (part 2) (Shrinkage test ) |
- |
250 |
|
- |
Cl. 4 Table 1of IS: 8783 (part 2) (Shrinkage test ) |
- |
250 |
|
- |
Cl. 4 Table 1of IS: 8783 (part 2) (Water absorption (Gravimetric) ) |
- |
1500 |
|
- |
Cl. 4 Table 1of IS: 8783 (part 2) (Hot deformation Test ) |
- |
250 |
|
- |
Cl. 4 Table 1of IS: 8783 (part 2) (Heat shock Test ) |
- |
250 |
|
- |
Cl.4.1(Insulation ) |
- |
0 |
|
- |
Cl.4.2(Application) |
- |
0 |
|
- |
Cl.4.3(Colour) |
- |
0 |
|
- |
Cl.4.4(Overall Diameter) |
- |
500 |
|
- |
Cl.4.5(Finish) |
- |
0 |
|
- |
Cl.4.6(High Voltage Test Water Immersion ) |
- |
3200 |
|
- |
|
Complete
|
|
16 Aug, 2024 |
- |
7 |
IS 8783 : Part 4 : Sec 3 (1995) |
Winding wires for submersible motors - Specification: Part 4 specification for individual wires: Sec 3 polyester and polypropylene insulated winding wires (First Revision) |
- |
-
|
13800 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
5.1(The winding wire shall either be wound on spools / reels conforming to IS 482-1981. or supplied in a coils packed and labelled.) |
- |
0 |
|
- |
6.1(The winding wire shall carry following information marked on the lable on spool / reel / coil;) |
- |
0 |
|
- |
6.2(BIS Certification Mark) |
- |
0 |
|
- |
4(i) Material) |
- |
0 |
|
- |
5(ii) Diameter [mm] Seperate wire:) |
- |
0 |
|
- |
4.1, table 1 & 2(a) Thickness of Polyster (mm)) |
- |
0 |
|
- |
4.2(Application of insulation) |
- |
0 |
|
- |
4.3(Colour of Insuation) |
- |
0 |
|
- |
4.4(Overall diameter (mm)) |
- |
0 |
|
- |
4(Before ageing Tensile strength [N/mm²]) |
- |
0 |
|
- |
4(High Voltage test [Water Immersion test] 3 KV for 1 Minute) |
- |
0 |
|
- |
4(Insulation Resistance test [ohm-cm] At 90 ºC) |
- |
0 |
|
- |
Clause No. 3(Insulation Resistance (Volume Resistivity at test temperature 90 º C )) |
- |
1000 |
|
- |
Clause No. 3(Water absorption) |
- |
4000 |
|
- |
Clause No. 3(Hot Deformation) |
- |
600 |
|
- |
Clause No. 3(Shrinkage) |
- |
500 |
|
- |
Clause No. 3(Heat Shock) |
- |
500 |
|
- |
Clause No. 3(Thickness of Insulation) |
- |
500 |
|
- |
Clause No. 3(Annealing Test) |
- |
500 |
|
- |
Clause No. 3(Conductor Diameter) |
- |
500 |
|
- |
Clause No. 3(Overall Dimensions) |
- |
500 |
|
- |
Clause No. 3(Insulation Resistance (Volume Resistivity at 27º C )) |
- |
1000 |
|
- |
Clause No. 3(High Voltage Test (Water Immersion test) at room temperature) |
- |
4500 |
|
- |
Clause No. 3(Conductor Resistance) |
- |
700 |
|
- |
|
Complete
|
|
16 Aug, 2024 |
- |
8 |
IS 17293 (2020) |
Electric Cables for Photovoltaic Systems for Rated Voltage 1 500 V d.c. |
- |
-
|
1208200 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Cl. 7.3, Table 1 to 5 of IS 8130:2013 & IS:10810 (Part 5)-1984(Conductor Resistance Test) |
- |
750 |
|
- |
Cl. 7.1.2 of IS 8130 : 2013 & IS:10810 (Part 1)-1984(Annealing Test (for copper)) |
- |
750 |
|
- |
Cl. 7.1.1 of IS 8130:2013 & IS:10810 (Part 4)-1984(Persulphate Test for tinned copper) |
- |
1000 |
|
- |
Annex G and Table 3 of IS 17293:2020(Ozone Resistance test) |
- |
14500 |
|
- |
IS 191 : 2007, IS 440(Copper purity test) |
- |
1200 |
|
- |
Table 3 of IS 17293:2020 & IS 10810 (Part 63)(Smoke density test.) |
- |
11000 |
|
- |
Cl 6.4.3 and Table 3 of IS 8130(Diameter of wire in conductor) |
- |
500 |
|
- |
Table-3 & Annex-F of IS 17293:2020 and IS 10810 (Part 7) 1984(Elongation at low temperature (Cold Elongation)) |
- |
7500 |
|
- |
Annex H and Table 3 of IS 17293:2020(Damp Heat test) |
- |
140000 |
|
- |
Cl. 5.3, 6.3 & Table 1 & 2 & IS:10810 (Part 6)-1984(Test for overall dimensions and thickness of insulation and sheath) |
- |
500 |
|
- |
Annex A of IS 17293-2020, IS:10810 (Part 7)-1984 & IS:10810 (Part 11)-1984(Tensile Strength and elongation at break before and after ageing.) |
- |
500 |
|
- |
Cl 11.2.3 & Table-3 of IS 17293:2020 & IS:10810 (Part 43)-1984(Insulation Resistance) |
- |
1500 |
|
- |
Annex B of IS 17293:2020 & IS:10810 (Part 11)-1984(Ageing in air oven.) |
- |
5000 |
|
- |
Annex J (J-1, J-2, J-3 & J-4) of IS 17293:2020(pH) |
- |
4000 |
|
- |
Annex J (J-1, J-2, J-3 & J-4) of IS 17293:2020(IS 17293) |
- |
4000 |
|
- |
Annex J (J-1, J-2, J-3 & J-4) of IS 17293:2020(HCl and HBr) |
- |
6000 |
|
- |
Annex J (J-1, J-2, J-3 & J-4) of IS 17293:2020(Presence of Fluorine / Fluorine Content (if required)) |
- |
21000 |
|
- |
Annex B of IS 17293:2020 & IS:10810 (Part 30)-1984(IS 10810-30) |
- |
1500 |
|
- |
"Annex B of IS 17293:2020 & IS:8504-1:2012 and IS: 8504-2: 2013"(Thermal endurance test) |
- |
385000 |
|
- |
Annex D and Table 3 of IS 17293:2020(Dynamic Penetration test) |
- |
5000 |
|
- |
Annex- I, Annex-B, Table-11 of IS 17293:2020 and IS 10810 (Part 1) : 1984(Sheath resistance against acid and alkaline solution) |
- |
16000 |
|
- |
Annex C of IS 17293:2020 & IS:10810 (Part 21)-1984(Cold impact test) |
- |
6500 |
|
- |
Annex - B of IS 17293:2020(Compatibility test) |
- |
5500 |
|
- |
Table 3 of IS 17293:2020 & IS:10810 (Part 20)-1984(Cold bend test) |
- |
6500 |
|
- |
Cl. 5.3, 6.3 & Table 1 & 2 & IS:10810 (Part 6)-1984(Test for overall dimensions and thickness of insulation and sheath) |
- |
1000 |
|
- |
Cl 5.3 of IS 17048:2018 & IS:10810 (Part 53)-1984(Flammability Test) |
- |
3000 |
|
- |
Annex A of IS 17293-2020, IS:10810 (Part 7)-1984 & IS:10810 (Part 11)-1984(Tensile Strength and elongation at break before and after ageing.) |
- |
1000 |
|
- |
Cl 11.2.1 of IS 17293:2020 & IS:10810 (Part 45)-1984(High voltage test) |
- |
2500 |
|
- |
Cl 5.7 & Annex D (D.1, D.2, D.3, D.4) of IS 17048:2018.(Presence of Fluorine / Fluorine Content (if required)) |
- |
21000 |
|
- |
Annex B of IS 17293:2020 & IS:10810 (Part 11)-1984(Ageing in air oven.) |
- |
5000 |
|
- |
Annex J (J-1, J-2, J-3 & J-4) of IS 17293:2020(pH) |
- |
4000 |
|
- |
Annex J (J-1, J-2, J-3 & J-4) of IS 17293:2020(Conductivity) |
- |
4000 |
|
- |
Annex J (J-1, J-2, J-3 & J-4) of IS 17293:2020(HCl and HBr) |
- |
6000 |
|
- |
Annex J (J-1, J-2, J-3 & J-4) of IS 17293:2020(Presence of Fluorine / Fluorine Content (if required)) |
- |
21000 |
|
- |
Annex B of IS 17293:2020 & IS:10810 (Part 30)-1984(Hot set test) |
- |
1500 |
|
- |
"Annex B of IS 17293:2020 & IS:8504-1:2012 and IS: 8504-2: 2013"(Thermal endurance test) |
- |
385000 |
|
- |
Annex- I, Annex-B, Table-11 of IS 17293:2020 and IS 10810 (Part 1) : 1984(Sheath resistance against acid and alkaline solution) |
- |
16000 |
|
- |
Annex - B of IS 17293:2020(Compatibility test) |
- |
5500 |
|
- |
Table 3 of IS 17293:2020 & IS:10810 (Part 12)-1984(Shrinkage test) |
- |
1000 |
|
- |
Annex - E of IS 17293 : 2020(UV resistance) |
- |
108000 |
|
- |
Cl 5.7 & Annex D (D.1, D.2, D.3, D.4) of IS 17048:2018.(pH) |
- |
4000 |
|
- |
Cl 5.7 & Annex D (D.1, D.2, D.3, D.4) of IS 17048:2018.(Conductivity) |
- |
4000 |
|
- |
Cl 5.7 & Annex D (D.1, D.2, D.3, D.4) of IS 17048:2018.(HCl and HBr) |
- |
6000 |
|
- |
Cl 5.7 & Annex D (D.1, D.2, D.3, D.4) of IS 17048:2018.(Presence of Fluorine / Fluorine Content (if required)) |
- |
21000 |
|
- |
|
Complete
|
|
16 Aug, 2024 |
- |
9 |
IS 1180 : Part 1 (2014) |
Outdoor Type Oil Immersed Distribution Transformers Upto and Including 2 500 kVA, 33kV - Specification Part 1 Mineral Oil Immersed (Fourth Revision) |
- |
-
|
122000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
13.1(Marking (Rating Plates)) |
- |
300 |
|
Charges for 33kV , 2500 kVA, 3-Phase Distribution Transformers. |
13.2(Terminal Marking Plate) |
- |
300 |
|
Charges for 33kV , 2500 kVA, 3-Phase Distribution Transformers. |
13.3(Marking ) |
- |
300 |
|
Charges for 33kV , 2500 kVA, 3-Phase Distribution Transformers. |
13.4(Marking) |
- |
300 |
|
Charges for 33kV , 2500 kVA, 3-Phase Distribution Transformers. |
13.4.1(Marking) |
- |
300 |
|
Charges for 33kV , 2500 kVA, 3-Phase Distribution Transformers. |
14.1(MOUNTING ARRANGEMENT) |
- |
500 |
|
Charges for 33kV , 2500 kVA, 3-Phase Distribution Transformers. |
14.2(MOUNTING ARRANGEMENT) |
- |
500 |
|
Charges for 33kV , 2500 kVA, 3-Phase Distribution Transformers. |
14.3(MOUNTING ARRANGEMENT) |
- |
500 |
|
Charges for 33kV , 2500 kVA, 3-Phase Distribution Transformers. |
14.4(MOUNTING ARRANGEMENT) |
- |
500 |
|
Charges for 33kV , 2500 kVA, 3-Phase Distribution Transformers. |
15.1.1(TRANSFORMER TANK : Construction) |
- |
1000 |
|
Charges for 33kV , 2500 kVA, 3-Phase Distribution Transformers. |
15.1.2(TRANSFORMER TANK : Construction) |
- |
1000 |
|
Charges for 33kV , 2500 kVA, 3-Phase Distribution Transformers. |
15.1.3(TRANSFORMER TANK : Construction) |
- |
1000 |
|
Charges for 33kV , 2500 kVA, 3-Phase Distribution Transformers. |
15.1.4(TRANSFORMER TANK : Construction) |
- |
1000 |
|
Charges for 33kV , 2500 kVA, 3-Phase Distribution Transformers. |
15.1.5(TRANSFORMER TANK : Construction) |
- |
1000 |
|
Charges for 33kV , 2500 kVA, 3-Phase Distribution Transformers. |
21.2 a)(Measurement of winding resistance ) |
- |
750 |
|
Charges for 33kV , 2500 kVA, 3-Phase Distribution Transformers.
Charges 750 Rs Applicable for each Tap. |
21.2 b)( Measurement of voltage ratio and check of
phase displacemen) |
- |
650 |
|
Charges for 33kV , 2500 kVA, 3-Phase Distribution Transformers.
Charges 650 Rs Applicable for each Tap. |
21.2 c)( Measurement of short-circuit impedance
(principal tapping, when applicable) and load
loss at 50 percent and 100 percent load) |
- |
950 |
|
Charges for 33kV , 2500 kVA, 3-Phase Distribution Transformers.
Charges 950 Rs Applicable for each Tap. |
21.2 d)(Measurement of no-load loss and current) |
- |
2000 |
|
Charges for 33kV , 2500 kVA, 3-Phase Distribution Transformers. |
21.2 e)(Measurement of insulation resistance) |
- |
1500 |
|
Charges for 33kV , 2500 kVA, 3-Phase Distribution Transformers. |
21.2 f)(Induced over-voltage withstand test) |
- |
3500 |
|
Charges for 33kV , 2500 kVA, 3-Phase Distribution Transformers. |
21.2 g)( Separate-source voltage withstand test) |
- |
3500 |
|
Charges for 33kV , 2500 kVA, 3-Phase Distribution Transformers. |
21.5.3.3(Oil leakage test) |
- |
6000 |
|
Charges for 33kV , 2500 kVA, 3-Phase Distribution Transformers. |
21.4 c(No load current at 112.5 percent voltage.) |
- |
1500 |
|
Charges for 33kV , 2500 kVA, 3-Phase Distribution Transformers. |
21.4 d(Paint adhesion tests) |
- |
1200 |
|
Charges for 33kV , 2500 kVA, 3-Phase Distribution Transformers. |
21.4 e(BDV and moisture content of oil in the transformer) |
- |
1500 |
|
Charges for 33kV , 2500 kVA, 3-Phase Distribution Transformers. |
6.9, 7.9, 8.9(Permissible Flux Density and Over Fluxing) |
- |
6300 |
|
Charges for 33kV , 2500 kVA, 3-Phase Distribution Transformers. |
11(Minimum clearance in Air) |
- |
1050 |
|
Charges for 33kV , 2500 kVA, 3-Phase Distribution Transformers. |
16(Conservator for Non-sealed type Transformers) |
- |
500 |
|
Charges for 33kV , 2500 kVA, 3-Phase Distribution Transformers. |
20(Fittings) |
- |
500 |
|
Charges for 33kV , 2500 kVA, 3-Phase Distribution Transformers. |
6.8 (50%)(Total losses at 50 % load (Watts)) |
- |
1250 |
|
Charges for 33kV , 2500 kVA, 3-Phase Distribution Transformers. |
7.8 (50%)(Total losses at 50 % load (Watts)) |
- |
1750 |
|
Charges for 33kV , 2500 kVA, 3-Phase Distribution Transformers. |
8.8 (50%)(Total losses at 50 % load (Watts)) |
- |
1000 |
|
Charges for 33kV , 2500 kVA, 3-Phase Distribution Transformers. |
6.8 (100%)(Total losses at 100 % load (Watts)) |
- |
1500 |
|
Charges for 33kV , 2500 kVA, 3-Phase Distribution Transformers. |
7.8 (100%)(Total losses at 100 % load (Watts)) |
- |
2000 |
|
Charges for 33kV , 2500 kVA, 3-Phase Distribution Transformers. |
8.8 (100%)(Total losses at 100 % load (Watts)) |
- |
1250 |
|
Charges for 33kV , 2500 kVA, 3-Phase Distribution Transformers. |
21.5.1.3(Oil leakage test upto 200 KVA) |
- |
4500 |
|
Charges for 33kV , 200 kVA, 3-Phase Distribution Transformers. |
21.5.3.1(For Single Phase Distribution Transformers Up to Including 25 kVA : pressure test (type test)) |
- |
2700 |
|
- |
21.5.3.2(For Single Phase Distribution Transformers Up to Including 25 kVA : pressure test (routine test)) |
- |
5000 |
|
- |
21.5.1.1(Pressure test-Type test (For Transformers up to 200 kVA
)) |
- |
3000 |
|
- |
21.5.1.2(Pressure test-routine test (For Transformers up to 200 kVA
)) |
- |
5000 |
|
- |
21.3(a )(Lightning impulse test) |
- |
35700 |
|
- |
21.3(b)(Temperature-rise test) |
- |
23500 |
|
- |
21.4 a)( Determination of sound levels) |
- |
6000 |
|
- |
|
Complete
|
|
16 Aug, 2024 |
- |
10 |
IS 17505 : Part 1 (2021) |
Specification for Thermosetting Insulated Fire Survival Cables for Fixed Installation having Low Emission of Smoke and Corrosive Gases when Affected by Fire for Working Voltages upto and including 1100 Vac and 1500 Vdc |
- |
-
|
150200 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Cl. 7.3, Table 1 to 5 of IS 8130:2013 & IS:10810 (Part 5)-1984(Conductor Resistance Test) |
- |
1600 |
|
- |
Cl. 7.1.2 of IS 8130 : 2013 & IS:10810 (Part 1)-1984(Annealing Test (for copper)) |
- |
700 |
|
- |
Cl. 7.1.1 of IS 8130:2013 & IS:10810 (Part 4)-1984(Persulphate Test for tinned copper) |
- |
1200 |
|
- |
IS 191:2007 & IS 440(Copper purity test) |
- |
1200 |
|
- |
Cl. 11,14,16, Table 4 and Table 6 of IS 17505 & IS:10810 (Part 6)-1984(Test for overall dimensions and thickness of insulation and sheath) |
- |
1500 |
|
- |
Table 7 of IS 17505-1:2021, IS 3975:1999 & IS:10810 (Part 36)-1984(Diameter of armour Wire) |
- |
500 |
|
- |
Table 7 of IS 17505-1:2021, IS 3975:1999 & IS:10810 (Part 37)-1984(Tensile strength and elongation at break) |
- |
1000 |
|
- |
Table 7 of IS 17505-1:2021, IS 3975:1999 & IS:10810 (Part 38)-1984(Torsion Test on galvanised steel wire for armouring) |
- |
500 |
|
- |
Table 7 of IS 17505-1:2021, IS 3975:1999 & IS:10810 (Part 39)-1984(Winding Test for Formed Wires) |
- |
500 |
|
- |
Table 7 of IS 17505-1:2021, IS 3975:1999 & IS:10810 (Part 40)-1984(Uniformity of Zinc coating on Round Steel Wires and Formed Steel Wires (Strips)) |
- |
1000 |
|
- |
Table 7 of IS 17505-1:2021, IS 3975:1999 & IS:10810 (Part 41)-1984(Mass of Zinc coating on Round Steel Wires and Formed Steel Wires (Strips)) |
- |
1500 |
|
- |
Table 7 of IS 17505-1:2021, IS 3975:1999 & IS:10810 (Part 42)-1984(Resistivity test) |
- |
1000 |
|
- |
Table 1 and Table 2 of IS 17505 -1: 2021, IS:10810 (Part 7)-1984 & IS:10810 (Part 11)-1984(Tensile Strength and elongation at break before and after ageing.) |
- |
750 |
|
- |
Cl 18.2 of IS 17505-1:2021 & IS:10810 (Part 45)-1984(High voltage test) |
- |
2500 |
|
- |
Table 1 of IS 17505-1 :2021 & IS:10810 (Part 43)-1984(Insulation Resistance) |
- |
2500 |
|
- |
Cl. 18.6 of IS 17505-1:2021 & IS:10810 (Part 58)-1998(Oxygen index) |
- |
2500 |
|
- |
Cl. 18.7 of IS 17505-1:2021 & IS:10810 (Part 64)-2003(Temperature Index) |
- |
2500 |
|
- |
Table-1 & Table-2 of IS 17505-1:2021 & IS:10810 (Part 11)-1984(Ageing in air oven.) |
- |
3250 |
|
- |
Specification for thermosetting insulated fire survival cables for fixed installation having low emission of smoke and corrosive gases when affected by fire for working voltages upto and including 1100 V A.C. and 1500 V D.C(Hot deformation) |
- |
1000 |
|
- |
Table-1 & Annex-F (F.1, F.2, F.3 F.4) of IS 17505-1 :2021(pH) |
- |
3000 |
|
- |
Table-1 & Annex-F (F.1, F.2, F.3 F.4) of IS 17505-1 :2021(Conductivity) |
- |
3000 |
|
- |
Table-1 & Annex-F (F.1, F.2, F.3 F.4) of IS 17505-1 :2021(HCl and HBr) |
- |
5000 |
|
- |
Table-1 & Annex-F (F.1, F.2, F.3 F.4) of IS 17505-1 :2021(Presence of Fluorine / Fluorine Content (if required)) |
- |
16250 |
|
- |
Table 1 of IS 17505-1: 2021 & IS:10810 (Part 21)-1984(Cold impact test) |
- |
3000 |
|
- |
Table 1 & 2 of IS 17505-1: 2021 & IS:10810 (Part 30)-1984(Hot set test) |
- |
3000 |
|
- |
Table 1 & 2 of IS 17505-1: 2021 & IS:10810 (Part 13)-1984(Ozone Resistance test) |
- |
14500 |
|
- |
Cl 18.5.1 of IS 17505-1 :2021 & IS:10810 (Part 61)-1988(Flame test on single cable) |
- |
3000 |
|
- |
Table 1 of IS 17505-1:2021 & IS:10810 (Part 12)-1984(Shrinkage test) |
- |
1000 |
|
- |
Cl 7 & Annex-F (F.1, F.2, F.3 F.4) of IS 17505-1 :2021(pH) |
- |
3000 |
|
- |
Cl 7 & Annex-F (F.1, F.2, F.3 F.4) of IS 17505-1 :2021(Conductivity) |
- |
3000 |
|
- |
Cl 7 & Annex-F (F.1, F.2, F.3 F.4) of IS 17505-1 :2021(HCl and HBr) |
- |
5000 |
|
- |
Cl 7 & Annex-F (F.1, F.2, F.3 F.4) of IS 17505-1 :2021(Presence of Fluorine / Fluorine Content (if required)) |
- |
16250 |
|
- |
Tabel 1 and 2 of IS 17505-1:2021 & IS:10810 (Part 7)-1984(Tensile strength and elongation at break.) |
- |
750 |
|
- |
Tabel 1 and 2 of IS 17505-1:2021 & IS:10810 (Part 11)-1984(Ageing in air oven.) |
- |
3250 |
|
- |
Cl 18.6 of IS 17505-1: 2021 & IS:10810 (Part 58)-1998(Oxygen Index.) |
- |
3000 |
|
- |
Cl 18.8 of IS 17505-1:2021 & IS:10810 (Part 64)-2003(Temperature Index) |
- |
3000 |
|
- |
Table 1 & 2 of IS 17505-1: 2021 & IS:10810 (Part 13)-1984(Ozone resistance test) |
- |
14500 |
|
- |
Table 2 of IS 17505-1:2021 & IS:10810 (Part 15)-1984(Hot deformation) |
- |
1000 |
|
- |
Cl 7 & Annex-F (F.1, F.2, F.3 F.4) of IS 17505-1 :2021(pH) |
- |
3000 |
|
- |
Cl 7 & Annex-F (F.1, F.2, F.3 F.4) of IS 17505-1 :2021(Conductivity) |
- |
3000 |
|
- |
Cl 7 & Annex-F (F.1, F.2, F.3 F.4) of IS 17505-1 :2021(HCl and HBr) |
- |
5000 |
|
- |
Cl 7 & Annex-F (F.1, F.2, F.3 F.4) of IS 17505-1 :2021(Presence of Fluorine / Fluorine Content (if required)) |
- |
16250 |
|
- |
Table 1 of IS 17505-1:2021 & IS:10810 (Part 12)-1984(Shrinkage test) |
- |
1000 |
|
- |
Cl 18.2of IS 17505-1:2021 & IS:10810 (Part 45)-1984.(High Voltage test.) |
- |
2500 |
|
- |
Cl 18.5of IS 17505-1:2021 & IS:10810 (Part 53)-1984(Flammability Test) |
- |
3000 |
|
- |
Table-2 of IS 17505-1:2021 & IS:10810 (Part 20)-1984(Cold bend test) |
- |
2000 |
|
- |
Table-2 of IS 17505-1:2021 & IS:10810 (Part 21)-1984(Cold impact test) |
- |
3000 |
|
- |
Cl 18.5 of IS 17505-1:2021 & IS:10810 (Part 61)-1988(Flammability Test) |
- |
12500 |
|
- |
Cl 18.9 of IS 17505-1:2021(Water immersion test ( effect of water on sheath of cable)) |
- |
5500 |
|
- |
Cl 18.8 of IS 17505-1:2021& IS:10810 (Part 63)-1993(Smoke density test) |
- |
10500 |
|
- |
Cl. 3.5, 18.4 & Annex-E of IS 17505-1:2021(Circuit integrity test under fire) |
- |
35000 |
|
- |
|
Complete
|
|
16 Aug, 2024 |
- |
11 |
IS 191 (2007) |
Copper - Specification (Fourth Revision) |
Copper |
-
|
9000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
5.1- Table 2(L) |
- |
0 |
|
- |
5.1- Table 2(L1) |
- |
0 |
|
- |
5.1- Table 2(h) |
- |
0 |
|
- |
5.1- Table 2(h1) |
- |
0 |
|
- |
5.1- Table 2(b) |
- |
0 |
|
- |
5.1- Table 2(b1) |
- |
0 |
|
- |
5.1- Table 2(R) |
- |
0 |
|
- |
5.1- Table 2(R1) |
- |
0 |
|
- |
5.1- Table 2(R2 ) |
- |
0 |
|
- |
5.1- Table 2(α ) |
- |
0 |
|
- |
5.1- Table 2( β ) |
- |
0 |
|
- |
5.1- Table 2(γ) |
- |
0 |
|
- |
5.2(Billets) |
- |
0 |
|
- |
5.4-Table 3 (For Billets)(Mass) |
- |
0 |
|
- |
5.2-Table 3 (For Billets)(Diameter) |
- |
0 |
|
- |
5.2-Table 3 (For Billets)(Length) |
- |
0 |
|
- |
5.2-Table 3 (For Billets)(Deviation from straightness per 1000 mm length) |
- |
0 |
|
- |
5.4-Table 3 (Vertically continuously cast wire bars)(Mass) |
- |
0 |
|
- |
5.3-Table 3 (Vertically continuously cast wire bars)(Width) |
- |
0 |
|
- |
5.3-Table 3 (Vertically continuously cast wire bars)(thickness ) |
- |
0 |
|
- |
5.3-Table 3 (Vertically continuously cast wire bars)(Other dimention) |
- |
0 |
|
- |
5.3-Table 3 (Vertically static cast wire bars)(Width) |
- |
0 |
|
- |
5.3-Table 3 (Vertically static cast wire bars)(thickness ) |
- |
0 |
|
- |
5.3-Table 3 (Vertically static cast wire bars)(Other dimention) |
- |
0 |
|
- |
5.4-Table 3 (Ingots)(Mass) |
- |
0 |
|
- |
5.4-Table 3 (Cast cakes)(Mass) |
- |
0 |
|
- |
5.3-Table 3 (Cast cakes)(Width) |
- |
0 |
|
- |
5.3-Table 3 (Cast cakes)(thickness ) |
- |
0 |
|
- |
5.3-Table 3 (Cast cakes)(Deviation from straightness per 1000 mm length) |
- |
0 |
|
- |
7.1 - Table 4(Copper + Silver(By difference)-IS440) |
- |
600 |
|
- |
7.1 - Table 4(Silver- IS 440) |
- |
600 |
|
- |
7.1 - Table 4(Copper (any Silver present to be counted as copper)-IS440) |
- |
0 |
|
- |
7.1 - Table 4(Phosphorus- IS 440) |
- |
600 |
|
- |
7.1 - Table 4(Arsenic- IS440) |
- |
600 |
|
- |
7.1 - Table 4(Antimony-IS440) |
- |
600 |
|
- |
7.1 - Table 4(Bismuth-IS 440) |
- |
600 |
|
- |
7.1 - Table 4(Iron IS 440) |
- |
600 |
|
- |
7.1 - Table 4(Lead IS 440) |
- |
600 |
|
- |
7.1 - Table 4(Nickel IS 440) |
- |
600 |
|
- |
7.1 - Table 4(Oxygen IS 440) |
- |
600 |
|
- |
7.1 - Table 4(Selenium - IS 440) |
- |
600 |
|
- |
7.1 - Table 4(Sulphur- IS 440) |
- |
600 |
|
- |
7.1 - Table 4(Tellurium- IS 440) |
- |
600 |
|
- |
7.1 - Table 4(Tin - IS 440) |
- |
600 |
|
- |
7.1 - Table 4(Znic-IS 440) |
- |
600 |
|
- |
7.1 - Table 4(Selenium + Telluuium- IS 440) |
- |
0 |
|
- |
7.1 - Table 4(Total Impurities- IS 440) |
- |
0 |
|
- |
8.1(FREEDOM FROM DEFECTS) |
- |
0 |
|
- |
8.2(FREEDOM FROM DEFECTS) |
- |
0 |
|
- |
9.1- Table 5(Mass Resistivity- IS 3635) |
- |
0 |
|
- |
10(HYDROGEN EMBRITTLEMENT TEST- IS 191) |
- |
0 |
|
- |
9.1- Table 5(Mass Resistivity- IS 3635) |
- |
0 |
|
- |
10(HYDROGEN EMBRITTLEMENT TEST- IS 191) |
- |
0 |
|
- |
4-Table 1(GRADES/DESIGNATIONS) |
- |
0 |
|
- |
5.1- Table 2(L) |
- |
0 |
|
- |
5.1- Table 2(L1) |
- |
0 |
|
- |
5.1- Table 2(h) |
- |
0 |
|
- |
5.1- Table 2(h1) |
- |
0 |
|
- |
5.1- Table 2(b1) |
- |
0 |
|
- |
5.1- Table 2(R) |
- |
0 |
|
- |
5.1- Table 2(R1) |
- |
0 |
|
- |
5.1- Table 2(R2 ) |
- |
0 |
|
- |
5.1- Table 2(α ) |
- |
0 |
|
- |
5.1- Table 2( β ) |
- |
0 |
|
- |
5.1- Table 2(γ) |
- |
0 |
|
- |
5.2(Billets) |
- |
0 |
|
- |
5.4-Table 3 (For Billets)(Mass) |
- |
0 |
|
- |
5.2-Table 3 (For Billets)(Diameter) |
- |
0 |
|
- |
5.2-Table 3 (For Billets)(Length) |
- |
0 |
|
- |
5.4-Table 3 (Vertically continuously cast wire bars)(Mass) |
- |
0 |
|
- |
5.3-Table 3 (Vertically continuously cast wire bars)(Width) |
- |
0 |
|
- |
5.3-Table 3 (Vertically continuously cast wire bars)(thickness ) |
- |
0 |
|
- |
5.3-Table 3 (Vertically continuously cast wire bars)(Other dimention) |
- |
0 |
|
- |
5.4-Table 3 (Vertically static cast wire bars)(Mass) |
- |
0 |
|
- |
5.3-Table 3 (Vertically static cast wire bars)(thickness ) |
- |
0 |
|
- |
5.3-Table 3 (Vertically static cast wire bars)(Other dimention) |
- |
0 |
|
- |
5.4-Table 3 (Ingots)(Mass) |
- |
0 |
|
- |
5.4-Table 3 (Cast cakes)(Mass) |
- |
0 |
|
- |
5.3-Table 3 (Cast cakes)(Width) |
- |
0 |
|
- |
5.3-Table 3 (Cast cakes)(thickness ) |
- |
0 |
|
- |
5.3-Table 3 (Cast cakes)(Deviation from straightness per 1000 mm length) |
- |
0 |
|
- |
7.1 - Table 4(Copper + Silver(By difference)-IS440) |
- |
0 |
|
- |
7.1 - Table 4(Silver- IS 440) |
- |
0 |
|
- |
7.1 - Table 4(Copper (any Silver present to be counted as copper)-IS440) |
- |
0 |
|
- |
7.1 - Table 4(Phosphorus- IS 440) |
- |
0 |
|
- |
7.1 - Table 4(Arsenic- IS440) |
- |
0 |
|
- |
7.1 - Table 4(Antimony-IS440) |
- |
0 |
|
- |
7.1 - Table 4(Bismuth-IS 440) |
- |
0 |
|
- |
7.1 - Table 4(Lead IS 440) |
- |
0 |
|
- |
7.1 - Table 4(Nickel IS 440) |
- |
0 |
|
- |
7.1 - Table 4(Oxygen IS 440) |
- |
0 |
|
- |
7.1 - Table 4(Selenium - IS 440) |
- |
0 |
|
- |
7.1 - Table 4(Sulphur- IS 440) |
- |
0 |
|
- |
7.1 - Table 4(Tellurium- IS 440) |
- |
0 |
|
- |
7.1 - Table 4(Tin - IS 440) |
- |
0 |
|
- |
7.1 - Table 4(Znic-IS 440) |
- |
0 |
|
- |
7.1 - Table 4(Selenium + Telluuium- IS 440) |
- |
0 |
|
- |
7.1 - Table 4(Total Impurities- IS 440) |
- |
0 |
|
- |
8.1(FREEDOM FROM DEFECTS) |
- |
0 |
|
- |
5.1- Table 2(L) |
- |
0 |
|
- |
5.1- Table 2(L1) |
- |
0 |
|
- |
5.1- Table 2(h) |
- |
0 |
|
- |
5.1- Table 2(h1) |
- |
0 |
|
- |
5.1- Table 2(b) |
- |
0 |
|
- |
5.1- Table 2(b1) |
- |
0 |
|
- |
5.1- Table 2(R) |
- |
0 |
|
- |
5.1- Table 2(R1) |
- |
0 |
|
- |
5.1- Table 2(R2 ) |
- |
0 |
|
- |
5.1- Table 2(α ) |
- |
0 |
|
- |
5.1- Table 2( β ) |
- |
0 |
|
- |
5.1- Table 2(γ) |
- |
0 |
|
- |
5.2(Billets) |
- |
0 |
|
- |
5.4-Table 3 (For Billets)(Mass) |
- |
0 |
|
- |
5.2-Table 3 (For Billets)(Diameter) |
- |
0 |
|
- |
5.2-Table 3 (For Billets)(Length) |
- |
0 |
|
- |
5.2-Table 3 (For Billets)(Deviation from straightness per 1000 mm length) |
- |
0 |
|
- |
5.4-Table 3 (Vertically continuously cast wire bars)(Mass) |
- |
0 |
|
- |
5.3-Table 3 (Vertically continuously cast wire bars)(Width) |
- |
0 |
|
- |
5.3-Table 3 (Vertically continuously cast wire bars)(thickness ) |
- |
0 |
|
- |
5.3-Table 3 (Vertically continuously cast wire bars)(Other dimention) |
- |
0 |
|
- |
5.3-Table 3 (Vertically static cast wire bars)(Width) |
- |
0 |
|
- |
5.3-Table 3 (Vertically static cast wire bars)(thickness ) |
- |
0 |
|
- |
5.3-Table 3 (Vertically static cast wire bars)(Other dimention) |
- |
0 |
|
- |
5.4-Table 3 (Ingots)(Mass) |
- |
0 |
|
- |
5.4-Table 3 (Cast cakes)(Mass) |
- |
0 |
|
- |
5.3-Table 3 (Cast cakes)(Width) |
- |
0 |
|
- |
5.3-Table 3 (Cast cakes)(thickness ) |
- |
0 |
|
- |
5.3-Table 3 (Cast cakes)(Deviation from straightness per 1000 mm length) |
- |
0 |
|
- |
7.1 - Table 4(Copper + Silver(By difference)-IS440) |
- |
0 |
|
- |
7.1 - Table 4(Silver- IS 440) |
- |
0 |
|
- |
7.1 - Table 4(Copper (any Silver present to be counted as copper)-IS440) |
- |
0 |
|
- |
7.1 - Table 4(Phosphorus- IS 440) |
- |
0 |
|
- |
7.1 - Table 4(Arsenic- IS440) |
- |
0 |
|
- |
7.1 - Table 4(Antimony-IS440) |
- |
0 |
|
- |
7.1 - Table 4(Bismuth-IS 440) |
- |
0 |
|
- |
7.1 - Table 4(Iron IS 440) |
- |
0 |
|
- |
7.1 - Table 4(Lead IS 440) |
- |
0 |
|
- |
7.1 - Table 4(Nickel IS 440) |
- |
0 |
|
- |
7.1 - Table 4(Oxygen IS 440) |
- |
0 |
|
- |
7.1 - Table 4(Selenium - IS 440) |
- |
0 |
|
- |
7.1 - Table 4(Sulphur- IS 440) |
- |
0 |
|
- |
7.1 - Table 4(Tellurium- IS 440) |
- |
0 |
|
- |
7.1 - Table 4(Tin - IS 440) |
- |
0 |
|
- |
7.1 - Table 4(Znic-IS 440) |
- |
0 |
|
- |
7.1 - Table 4(Selenium + Telluuium- IS 440) |
- |
0 |
|
- |
7.1 - Table 4(Total Impurities- IS 440) |
- |
0 |
|
- |
8.1(FREEDOM FROM DEFECTS) |
- |
0 |
|
- |
8.2(FREEDOM FROM DEFECTS) |
- |
0 |
|
- |
9.1- Table 5(Mass Resistivity- IS 3635) |
- |
0 |
|
- |
10(HYDROGEN EMBRITTLEMENT TEST- IS 191) |
- |
0 |
|
- |
9.1- Table 5(Mass Resistivity- IS 3635) |
- |
0 |
|
- |
10(HYDROGEN EMBRITTLEMENT TEST- IS 191) |
- |
0 |
|
- |
4-Table 1(GRADES/DESIGNATIONS) |
- |
0 |
|
- |
5.1- Table 2(L) |
- |
0 |
|
- |
5.1- Table 2(L1) |
- |
0 |
|
- |
5.1- Table 2(h) |
- |
0 |
|
- |
5.1- Table 2(h1) |
- |
0 |
|
- |
5.1- Table 2(b1) |
- |
0 |
|
- |
5.1- Table 2(R) |
- |
0 |
|
- |
5.1- Table 2(R1) |
- |
0 |
|
- |
5.1- Table 2(R2 ) |
- |
0 |
|
- |
5.1- Table 2(α ) |
- |
0 |
|
- |
5.1- Table 2( β ) |
- |
0 |
|
- |
5.1- Table 2(γ) |
- |
0 |
|
- |
5.2(Billets) |
- |
0 |
|
- |
5.4-Table 3 (For Billets)(Mass) |
- |
0 |
|
- |
5.2-Table 3 (For Billets)(Diameter) |
- |
0 |
|
- |
5.2-Table 3 (For Billets)(Length) |
- |
0 |
|
- |
5.4-Table 3 (Vertically continuously cast wire bars)(Mass) |
- |
0 |
|
- |
5.3-Table 3 (Vertically continuously cast wire bars)(Width) |
- |
0 |
|
- |
5.3-Table 3 (Vertically continuously cast wire bars)(thickness ) |
- |
0 |
|
- |
5.3-Table 3 (Vertically continuously cast wire bars)(Other dimention) |
- |
0 |
|
- |
5.4-Table 3 (Vertically static cast wire bars)(Mass) |
- |
0 |
|
- |
5.3-Table 3 (Vertically static cast wire bars)(thickness ) |
- |
0 |
|
- |
5.3-Table 3 (Vertically static cast wire bars)(Other dimention) |
- |
0 |
|
- |
5.4-Table 3 (Ingots)(Mass) |
- |
0 |
|
- |
5.4-Table 3 (Cast cakes)(Mass) |
- |
0 |
|
- |
5.3-Table 3 (Cast cakes)(Width) |
- |
0 |
|
- |
5.3-Table 3 (Cast cakes)(thickness ) |
- |
0 |
|
- |
5.3-Table 3 (Cast cakes)(Deviation from straightness per 1000 mm length) |
- |
0 |
|
- |
7.1 - Table 4(Copper + Silver(By difference)-IS440) |
- |
0 |
|
- |
7.1 - Table 4(Silver- IS 440) |
- |
0 |
|
- |
7.1 - Table 4(Copper (any Silver present to be counted as copper)-IS440) |
- |
0 |
|
- |
7.1 - Table 4(Phosphorus- IS 440) |
- |
0 |
|
- |
7.1 - Table 4(Arsenic- IS440) |
- |
0 |
|
- |
7.1 - Table 4(Antimony-IS440) |
- |
0 |
|
- |
7.1 - Table 4(Bismuth-IS 440) |
- |
0 |
|
- |
7.1 - Table 4(Lead IS 440) |
- |
0 |
|
- |
7.1 - Table 4(Nickel IS 440) |
- |
0 |
|
- |
7.1 - Table 4(Oxygen IS 440) |
- |
0 |
|
- |
7.1 - Table 4(Selenium - IS 440) |
- |
0 |
|
- |
7.1 - Table 4(Sulphur- IS 440) |
- |
0 |
|
- |
7.1 - Table 4(Tellurium- IS 440) |
- |
0 |
|
- |
7.1 - Table 4(Tin - IS 440) |
- |
0 |
|
- |
7.1 - Table 4(Znic-IS 440) |
- |
0 |
|
- |
7.1 - Table 4(Selenium + Telluuium- IS 440) |
- |
0 |
|
- |
7.1 - Table 4(Total Impurities- IS 440) |
- |
0 |
|
- |
8.1(FREEDOM FROM DEFECTS) |
- |
0 |
|
- |
5.1- Table 2(L) |
- |
- |
|
- |
5.1- Table 2(L1) |
- |
- |
|
- |
5.1- Table 2(h) |
- |
- |
|
- |
5.1- Table 2(h1) |
- |
- |
|
- |
5.1- Table 2(b) |
- |
- |
|
- |
5.1- Table 2(b1) |
- |
- |
|
- |
5.1- Table 2(R) |
- |
- |
|
- |
5.1- Table 2(R1) |
- |
- |
|
- |
5.1- Table 2(R2 ) |
- |
- |
|
- |
5.1- Table 2(α ) |
- |
- |
|
- |
5.1- Table 2( β ) |
- |
- |
|
- |
5.1- Table 2(γ) |
- |
- |
|
- |
5.2(Billets) |
- |
- |
|
- |
5.4-Table 3 (For Billets)(Mass) |
- |
- |
|
- |
5.2-Table 3 (For Billets)(Diameter) |
- |
- |
|
- |
5.2-Table 3 (For Billets)(Length) |
- |
- |
|
- |
5.2-Table 3 (For Billets)(Deviation from straightness per 1000 mm length) |
- |
- |
|
- |
5.4-Table 3 (Vertically continuously cast wire bars)(Mass) |
- |
- |
|
- |
5.3-Table 3 (Vertically continuously cast wire bars)(Width) |
- |
- |
|
- |
5.3-Table 3 (Vertically continuously cast wire bars)(thickness ) |
- |
- |
|
- |
5.3-Table 3 (Vertically continuously cast wire bars)(Other dimention) |
- |
- |
|
- |
5.3-Table 3 (Vertically static cast wire bars)(Width) |
- |
- |
|
- |
5.3-Table 3 (Vertically static cast wire bars)(thickness ) |
- |
- |
|
- |
5.3-Table 3 (Vertically static cast wire bars)(Other dimention) |
- |
- |
|
- |
5.4-Table 3 (Ingots)(Mass) |
- |
- |
|
- |
5.4-Table 3 (Cast cakes)(Mass) |
- |
- |
|
- |
5.3-Table 3 (Cast cakes)(Width) |
- |
- |
|
- |
5.3-Table 3 (Cast cakes)(thickness ) |
- |
- |
|
- |
5.3-Table 3 (Cast cakes)(Deviation from straightness per 1000 mm length) |
- |
- |
|
- |
7.1 - Table 4(Copper + Silver(By difference)-IS440) |
- |
- |
|
- |
7.1 - Table 4(Silver- IS 440) |
- |
- |
|
- |
7.1 - Table 4(Copper (any Silver present to be counted as copper)-IS440) |
- |
- |
|
- |
7.1 - Table 4(Phosphorus- IS 440) |
- |
- |
|
- |
7.1 - Table 4(Arsenic- IS440) |
- |
- |
|
- |
7.1 - Table 4(Antimony-IS440) |
- |
- |
|
- |
7.1 - Table 4(Bismuth-IS 440) |
- |
- |
|
- |
7.1 - Table 4(Iron IS 440) |
- |
- |
|
- |
7.1 - Table 4(Lead IS 440) |
- |
- |
|
- |
7.1 - Table 4(Nickel IS 440) |
- |
- |
|
- |
7.1 - Table 4(Oxygen IS 440) |
- |
- |
|
- |
7.1 - Table 4(Selenium - IS 440) |
- |
- |
|
- |
7.1 - Table 4(Sulphur- IS 440) |
- |
- |
|
- |
7.1 - Table 4(Tellurium- IS 440) |
- |
- |
|
- |
7.1 - Table 4(Tin - IS 440) |
- |
- |
|
- |
7.1 - Table 4(Znic-IS 440) |
- |
- |
|
- |
7.1 - Table 4(Selenium + Telluuium- IS 440) |
- |
- |
|
- |
7.1 - Table 4(Total Impurities- IS 440) |
- |
- |
|
- |
8.1(FREEDOM FROM DEFECTS) |
- |
- |
|
- |
8.2(FREEDOM FROM DEFECTS) |
- |
- |
|
- |
9.1- Table 5(Mass Resistivity- IS 3635) |
- |
- |
|
- |
10(HYDROGEN EMBRITTLEMENT TEST- IS 191) |
- |
- |
|
- |
9.1- Table 5(Mass Resistivity- IS 3635) |
- |
- |
|
- |
10(HYDROGEN EMBRITTLEMENT TEST- IS 191) |
- |
- |
|
- |
4-Table 1(GRADES/DESIGNATIONS) |
- |
- |
|
- |
5.1- Table 2(L) |
- |
- |
|
- |
5.1- Table 2(L1) |
- |
- |
|
- |
5.1- Table 2(h) |
- |
- |
|
- |
5.1- Table 2(h1) |
- |
- |
|
- |
5.1- Table 2(b1) |
- |
- |
|
- |
5.1- Table 2(R) |
- |
- |
|
- |
5.1- Table 2(R1) |
- |
- |
|
- |
5.1- Table 2(R2 ) |
- |
- |
|
- |
5.1- Table 2(α ) |
- |
- |
|
- |
5.1- Table 2( β ) |
- |
- |
|
- |
5.1- Table 2(γ) |
- |
- |
|
- |
5.2(Billets) |
- |
- |
|
- |
5.4-Table 3 (For Billets)(Mass) |
- |
- |
|
- |
5.2-Table 3 (For Billets)(Diameter) |
- |
- |
|
- |
5.2-Table 3 (For Billets)(Length) |
- |
- |
|
- |
5.4-Table 3 (Vertically continuously cast wire bars)(Mass) |
- |
- |
|
- |
5.3-Table 3 (Vertically continuously cast wire bars)(Width) |
- |
- |
|
- |
5.3-Table 3 (Vertically continuously cast wire bars)(thickness ) |
- |
- |
|
- |
5.3-Table 3 (Vertically continuously cast wire bars)(Other dimention) |
- |
- |
|
- |
5.4-Table 3 (Vertically static cast wire bars)(Mass) |
- |
- |
|
- |
5.3-Table 3 (Vertically static cast wire bars)(thickness ) |
- |
- |
|
- |
5.3-Table 3 (Vertically static cast wire bars)(Other dimention) |
- |
- |
|
- |
5.4-Table 3 (Ingots)(Mass) |
- |
- |
|
- |
5.4-Table 3 (Cast cakes)(Mass) |
- |
- |
|
- |
5.3-Table 3 (Cast cakes)(Width) |
- |
- |
|
- |
5.3-Table 3 (Cast cakes)(thickness ) |
- |
- |
|
- |
5.3-Table 3 (Cast cakes)(Deviation from straightness per 1000 mm length) |
- |
- |
|
- |
7.1 - Table 4(Copper + Silver(By difference)-IS440) |
- |
- |
|
- |
7.1 - Table 4(Silver- IS 440) |
- |
- |
|
- |
7.1 - Table 4(Copper (any Silver present to be counted as copper)-IS440) |
- |
- |
|
- |
7.1 - Table 4(Phosphorus- IS 440) |
- |
- |
|
- |
7.1 - Table 4(Arsenic- IS440) |
- |
- |
|
- |
7.1 - Table 4(Antimony-IS440) |
- |
- |
|
- |
7.1 - Table 4(Bismuth-IS 440) |
- |
- |
|
- |
7.1 - Table 4(Lead IS 440) |
- |
- |
|
- |
7.1 - Table 4(Nickel IS 440) |
- |
- |
|
- |
7.1 - Table 4(Oxygen IS 440) |
- |
- |
|
- |
7.1 - Table 4(Selenium - IS 440) |
- |
- |
|
- |
7.1 - Table 4(Sulphur- IS 440) |
- |
- |
|
- |
7.1 - Table 4(Tellurium- IS 440) |
- |
- |
|
- |
7.1 - Table 4(Tin - IS 440) |
- |
- |
|
- |
7.1 - Table 4(Znic-IS 440) |
- |
- |
|
- |
7.1 - Table 4(Selenium + Telluuium- IS 440) |
- |
- |
|
- |
7.1 - Table 4(Total Impurities- IS 440) |
- |
- |
|
- |
8.1(FREEDOM FROM DEFECTS) |
- |
- |
|
- |
|
Complete
|
|
16 Aug, 2024 |
- |
12 |
IS 335 (2018) |
New insulating oils - Specification (Fifth Revision) |
New Insulating Oil |
-
|
38700 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
6.2(Pour Point) |
- |
1000 |
|
- |
6..3(Water Content) |
- |
1500 |
|
- |
6.4(Breakdown Voltage) |
- |
1700 |
|
- |
6.16(Density) |
- |
1000 |
|
- |
6.5(Dielectric Dissipation Factor (DDF)) |
- |
2000 |
|
- |
6.2(Particle Content) |
- |
2000 |
|
- |
6.6(Appearance) |
- |
500 |
|
- |
6.7(Acidity) |
- |
1000 |
|
- |
6.8(Interfacial Tension (IFT)) |
- |
1000 |
|
- |
4, 5.2, 6, Table 2(Viscosity at 0°C) |
- |
500 |
|
- |
4, 5.2, 6, Table 2(Viscosity at -30°C) |
- |
1000 |
|
- |
4, 5.2, 6, Table 2(Viscosity at -40°C) |
- |
1000 |
|
- |
6.9(Sulphur Content) |
- |
2000 |
|
- |
4, 5.2, 6, Table 2(Corrosive sulphur) |
- |
500 |
|
- |
4, 5.2, 6, Table 2(Potentially corrosive sulphur) |
- |
500 |
|
- |
4, 5.2, 6, Table 2(DBDS) |
- |
2000 |
|
- |
4, 5.2, 6, Table 2(Metal passivator additives according to IS 13631/IEC 60666) |
- |
2500 |
|
- |
4, 5.2, 6, Table 2(Inhibitors according to IS 13631/IEC 60666) |
- |
2500 |
|
- |
4, 5.2, 6, Table 2(2-Furfural and related compounds content) |
- |
2500 |
|
- |
5.1(Classification) |
- |
0 |
|
- |
5.2(Requirements) |
- |
0 |
|
- |
5.3(Miscibility) |
- |
0 |
|
- |
6.0(General) |
- |
0 |
|
- |
6.1(Viscosity) |
- |
500 |
|
- |
6.1(Corrosive Sulphur and Potentially Corrosive Sulphur) |
- |
0 |
|
- |
6.11(Additives) |
- |
0 |
|
- |
6.12(Oxidation Stability) |
- |
4000 |
|
- |
6.13(Gassing Tendency) |
- |
1500 |
|
- |
6.14(Electrostatic Charging Tendency (ECT)) |
- |
0 |
|
- |
6.15(Flash Point) |
- |
1000 |
|
- |
6.17(Polycyclic Aromatics (PCA)) |
- |
2500 |
|
- |
6.18(Polychlorinated Biphenyls (PCB)) |
- |
2500 |
|
- |
6.19(2-Furfural (2-FAL) and Related Compounds Content) |
- |
0 |
|
- |
6.21(DBDS Content) |
- |
0 |
|
- |
6.22(Stray Gassing of Oil) |
- |
0 |
|
- |
7.1 (a)(Total acidity) |
- |
0 |
|
- |
7.1 (b)(Sludge) |
- |
0 |
|
- |
7.1 (c)(DDF at 90°C) |
- |
0 |
|
- |
7.1 (d)(Total sulphur content) |
- |
0 |
|
- |
7.2(Electrostatic Charging Tendency (ECT)) |
- |
0 |
|
- |
7.3(Gassing Tendency) |
- |
0 |
|
- |
4, 5.1.3, 6.1, Table 1(LCSET) |
- |
0 |
|
- |
4, 5.1.3, 6.1, Table 1(Maximum Viscosity) |
- |
0 |
|
- |
4, 5.1.3, 6.1, Table 1(Maximum Pour Point) |
- |
0 |
|
- |
6.2(Pour Point) |
- |
0 |
|
- |
6..3(Water Content) |
- |
0 |
|
- |
6.4(Breakdown Voltage) |
- |
0 |
|
- |
6.16(Density) |
- |
0 |
|
- |
6.5(Dielectric Dissipation Factor (DDF)) |
- |
0 |
|
- |
6.2(Particle Content) |
- |
0 |
|
- |
6.6(Appearance) |
- |
0 |
|
- |
6.7(Acidity) |
- |
0 |
|
- |
6.8(Interfacial Tension (IFT)) |
- |
0 |
|
- |
4, 5.2, 6, Table 2(Viscosity at 0°C) |
- |
0 |
|
- |
4, 5.2, 6, Table 2(Viscosity at -30°C) |
- |
0 |
|
- |
4, 5.2, 6, Table 2(Viscosity at -40°C) |
- |
0 |
|
- |
6.9(Sulphur Content) |
- |
0 |
|
- |
4, 5.2, 6, Table 2(Corrosive sulphur) |
- |
0 |
|
- |
4, 5.2, 6, Table 2(Potentially corrosive sulphur) |
- |
0 |
|
- |
4, 5.2, 6, Table 2(DBDS) |
- |
0 |
|
- |
4, 5.2, 6, Table 2(Metal passivator additives according to IS 13631/IEC 60666) |
- |
0 |
|
- |
4, 5.2, 6, Table 2(Inhibitors according to IS 13631/IEC 60666) |
- |
0 |
|
- |
4, 5.2, 6, Table 2(2-Furfural and related compounds content) |
- |
0 |
|
- |
5.1(Classification) |
- |
0 |
|
- |
5.2(Requirements) |
- |
0 |
|
- |
5.3(Miscibility) |
- |
0 |
|
- |
6.0(General) |
- |
0 |
|
- |
6.1(Viscosity) |
- |
0 |
|
- |
6.1(Corrosive Sulphur and Potentially Corrosive Sulphur) |
- |
0 |
|
- |
6.11(Additives) |
- |
0 |
|
- |
6.12(Oxidation Stability) |
- |
0 |
|
- |
6.13(Gassing Tendency) |
- |
0 |
|
- |
6.14(Electrostatic Charging Tendency (ECT)) |
- |
0 |
|
- |
6.15(Flash Point) |
- |
0 |
|
- |
6.17(Polycyclic Aromatics (PCA)) |
- |
0 |
|
- |
6.18(Polychlorinated Biphenyls (PCB)) |
- |
0 |
|
- |
6.19(2-Furfural (2-FAL) and Related Compounds Content) |
- |
0 |
|
- |
6.21(DBDS Content) |
- |
0 |
|
- |
6.22(Stray Gassing of Oil) |
- |
0 |
|
- |
7.1 (a)(Total acidity) |
- |
0 |
|
- |
7.1 (b)(Sludge) |
- |
0 |
|
- |
7.1 (c)(DDF at 90°C) |
- |
0 |
|
- |
7.1 (d)(Total sulphur content) |
- |
0 |
|
- |
7.2(Electrostatic Charging Tendency (ECT)) |
- |
0 |
|
- |
7.3(Gassing Tendency) |
- |
0 |
|
- |
4, 5.1.3, 6.1, Table 1(LCSET) |
- |
0 |
|
- |
4, 5.1.3, 6.1, Table 1(Maximum Viscosity) |
- |
0 |
|
- |
4, 5.1.3, 6.1, Table 1(Maximum Pour Point) |
- |
0 |
|
- |
6.2(Pour Point) |
- |
- |
|
- |
6..3(Water Content) |
- |
- |
|
- |
6.4(Breakdown Voltage) |
- |
- |
|
- |
6.16(Density) |
- |
- |
|
- |
6.5(Dielectric Dissipation Factor (DDF)) |
- |
- |
|
- |
6.2(Particle Content) |
- |
- |
|
- |
6.6(Appearance) |
- |
- |
|
- |
6.7(Acidity) |
- |
- |
|
- |
6.8(Interfacial Tension (IFT)) |
- |
- |
|
- |
4, 5.2, 6, Table 2(Viscosity at 0°C) |
- |
- |
|
- |
4, 5.2, 6, Table 2(Viscosity at -30°C) |
- |
- |
|
- |
4, 5.2, 6, Table 2(Viscosity at -40°C) |
- |
- |
|
- |
6.9(Sulphur Content) |
- |
- |
|
- |
4, 5.2, 6, Table 2(Corrosive sulphur) |
- |
- |
|
- |
4, 5.2, 6, Table 2(Potentially corrosive sulphur) |
- |
- |
|
- |
4, 5.2, 6, Table 2(DBDS) |
- |
- |
|
- |
4, 5.2, 6, Table 2(Metal passivator additives according to IS 13631/IEC 60666) |
- |
- |
|
- |
4, 5.2, 6, Table 2(Inhibitors according to IS 13631/IEC 60666) |
- |
- |
|
- |
4, 5.2, 6, Table 2(2-Furfural and related compounds content) |
- |
- |
|
- |
5.1(Classification) |
- |
- |
|
- |
5.2(Requirements) |
- |
- |
|
- |
5.3(Miscibility) |
- |
- |
|
- |
6.0(General) |
- |
- |
|
- |
6.1(Viscosity) |
- |
- |
|
- |
6.1(Corrosive Sulphur and Potentially Corrosive Sulphur) |
- |
- |
|
- |
6.11(Additives) |
- |
- |
|
- |
6.12(Oxidation Stability) |
- |
- |
|
- |
6.13(Gassing Tendency) |
- |
- |
|
- |
6.14(Electrostatic Charging Tendency (ECT)) |
- |
- |
|
- |
6.15(Flash Point) |
- |
- |
|
- |
6.17(Polycyclic Aromatics (PCA)) |
- |
- |
|
- |
6.18(Polychlorinated Biphenyls (PCB)) |
- |
- |
|
- |
6.19(2-Furfural (2-FAL) and Related Compounds Content) |
- |
- |
|
- |
6.21(DBDS Content) |
- |
- |
|
- |
6.22(Stray Gassing of Oil) |
- |
- |
|
- |
7.1 (a)(Total acidity) |
- |
- |
|
- |
7.1 (b)(Sludge) |
- |
- |
|
- |
7.1 (c)(DDF at 90°C) |
- |
- |
|
- |
7.1 (d)(Total sulphur content) |
- |
- |
|
- |
7.2(Electrostatic Charging Tendency (ECT)) |
- |
- |
|
- |
7.3(Gassing Tendency) |
- |
- |
|
- |
4, 5.1.3, 6.1, Table 1(LCSET) |
- |
- |
|
- |
4, 5.1.3, 6.1, Table 1(Maximum Viscosity) |
- |
- |
|
- |
4, 5.1.3, 6.1, Table 1(Maximum Pour Point) |
- |
- |
|
- |
|
Complete
|
|
16 Aug, 2024 |
- |
13 |
IS 16246 (2015) |
Elastomer insulated cables with limited circuit integrity when affected by fire - Specification |
- |
-
|
101500 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Cl.4.1( Cables for Fixed Installation) |
- |
0 |
|
- |
Cl.5( INSULATION) |
- |
0 |
|
- |
Cl. 6.1( Glass Tape) |
- |
0 |
|
- |
Cl 6.2( Polyethylene Teraphthalate (PETP) or Polypropylene base Tape) |
- |
0 |
|
- |
Cl 6.4( Fire Barrier Tape) |
- |
0 |
|
- |
Cl 7(CENTRE AND FILLERS) |
- |
0 |
|
- |
Cl 8( ARMOUR) |
- |
750 |
|
- |
Cl 9.1( Inner Sheath) |
- |
0 |
|
- |
Cl 9.2( Outer Sheath) |
- |
0 |
|
- |
Cl 10.1( CONDUCTORS) |
- |
0 |
|
- |
Cl 10.2( CONDUCTORS) |
- |
0 |
|
- |
Cl 11.1( INSULATION) |
- |
5000 |
|
For T.S. & Elongation at break after ageing in air oven on insulation. |
Cl 11.2(Thickness of Insulation IS 10810 : Part 6) |
- |
300 |
|
- |
Cl 12( CORE IDENTIFICATION) |
- |
0 |
|
- |
Cl 13( LAYING UP OF CORES) |
- |
0 |
|
- |
Cl 14.2( Thickness of Inner Sheath IS 10810 : Part 6) |
- |
100 |
|
- |
Cl 15.1( ARMOURING) |
- |
0 |
|
- |
Cl 15.3.1( Type of Armour) |
- |
0 |
|
- |
Cl 15.3.2( Type of Armour) |
- |
0 |
|
- |
Cl 15.3.3( ARMOURING) |
- |
0 |
|
- |
Cl 15.4.1( ARMOURING) |
- |
0 |
|
- |
Cl 15.4.2( ARMOURING) |
- |
6000 |
|
TS & ELONAGTION , TORSION, WINDING TEST,UNIFORMITY OF ZINC COATING, MASS OF ZINC COATING, RESISTIVITY OF ARMOUR WIRES |
Cl 16.2( OUTER SHEATH) |
- |
5000 |
|
For T.S. & Elongation at break after ageing in air oven on outer sheath. |
Cl 16.3( Thickness of Outer Sheath - Avg IS 10810 : Part 6) |
- |
100 |
|
- |
Cl 16.3( Thickness of Outer Sheath - Minimum IS 10810 : Part 6) |
- |
0 |
|
- |
Cl 17.2(Annealing test (for copper) IS 10810 : Part 1) |
- |
750 |
|
- |
Cl 17.2(Conductor resistance test IS 10810 : Part 5) |
- |
1000 |
|
- |
Cl 17.1(Persulphate test (tinned copper conductor) IS 10810 : Part 4) |
- |
1000 |
|
- |
Cl 17.2(Tensile strength before ageing on insulation IS 10810 : Part 7) |
- |
1000 |
|
- |
Cl 17.2(elongation at break before ageing on insulation IS 10810 : Part 7) |
- |
1000 |
|
- |
Cl 17.2(Tensile strength after Ageing in air bomb IS 10810 : Part 56) |
- |
2500 |
|
- |
Cl 17.2(Elongation after Ageing in air bomb IS 10810 : Part 56) |
- |
2000 |
|
- |
Cl 17.2(Tensile strength variation) |
- |
250 |
|
- |
Cl 17.2(Elongation Variation) |
- |
250 |
|
- |
Cl 17.2(Hot set elongation on insulation IS 10810 : Part 30) |
- |
1000 |
|
- |
Cl 17.2(Permanent elongation (set) on insulation IS 10810 : Part 30) |
- |
500 |
|
- |
Cl 17.1(Tensile strength before ageing on sheath IS 10810 : Part 7) |
- |
1000 |
|
- |
Cl 17.1(Hot set elongation test on sheath IS 10810 : Part 30) |
- |
1000 |
|
- |
Cl 17.1(Permanent elongation (set) test on sheath IS 10810 : Part 30) |
- |
500 |
|
- |
Cl 17.1(elongation at break before ageing on sheath IS 10810 : Part 7) |
- |
1000 |
|
- |
Cl 17.1(Oxygen index test on sheath IS 10810 : Part 58) |
- |
2500 |
|
- |
Cl 17.1(Temperature index test on sheath IS 10810 : Part 64) |
- |
2500 |
|
- |
Cl 17.1(Acid gas generation on sheath IS 10810 : Part 39) |
- |
5000 |
|
- |
Cl 17.2(Insulation resistance test IS 10810 : Part 43) |
- |
1500 |
|
- |
Cl 17.1(Water absorption test (for insulation) IS 10810 : Part 28) |
- |
5000 |
|
- |
Cl 18.2(High Voltage Test IS 10810 : Part 45) |
- |
1000 |
|
- |
Cl 18.2(High Voltage Test IS 10810 : Part 45) |
- |
1000 |
|
- |
Cl 18.3 Annex B of IS 16246( Circuit Integrity Test Under Fire Condition) |
- |
15000 |
|
- |
Cl 18.3 Annex B of IS 16246( Circuit Integrity Test Under Fire Condition) |
- |
15000 |
|
- |
Cl 18.4.1( Flame Retardence Test on Single Cable IS 10810 : Part 61) |
- |
3000 |
|
- |
Cl 18.4.2(Flame Retardence Test on Bunched Cables IS 10810 : Part 63) |
- |
18000 |
|
- |
Cl 19.1( Manufacturer’s Identification) |
- |
0 |
|
- |
Cl 19.2( Voltage Identification) |
- |
0 |
|
- |
Cl 19.3( Cable Identification) |
- |
0 |
|
- |
Cl 19.4( Cable Code) |
- |
0 |
|
- |
|
Complete
|
|
16 Aug, 2024 |
- |
14 |
IS 17048 (2018) |
Halogen free flame retardant (HFFR) cables for working voltages up to and including 1 100 Volts - Specification |
- |
-
|
199750 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
4.1.1 a) (Conductor : Material ) |
- |
0 |
|
- |
4.1.1 b) (Material : Seperator tape ) |
- |
0 |
|
- |
4.1.1 d) , 11.1, 12.1, 13.1,14.1(Class of conductor ) |
- |
0 |
|
- |
4.1.1 e) (Shape of conductor ) |
- |
0 |
|
- |
4.1.1 f) (Nominal size of conductor ) |
- |
0 |
|
- |
4.2.1, 11.2, 12.2, 13.2, 14.2(Insulation : Material ) |
- |
0 |
|
- |
4.2.2, 11.2, 12.2, 13.2, 14.2(Insulation : Application ) |
- |
0 |
|
- |
4.2.3,11.2, 12.2, 13.2(Thickness of insulation - Avearge : IS 10810 ( Part 6 )) |
- |
500 |
|
- |
4.2.3, 11.2, 12.2, 13.2, 14.2(Thickness of insulation - miniumum : IS 10810 ( Part 6 )) |
- |
500 |
|
- |
4.2.4(Insulation : Tensile stregth ( Before ageing)-IS 10810 (Part 7) ) |
- |
1000 |
|
- |
4.2.4(Insulation : Elongation ( Before ageing) -IS 10810 (Part 7)) |
- |
1000 |
|
- |
4.2.4(Insulation : Tensile stregth ( After ageing) - IS 10810 (Part 7) ) |
- |
1250 |
|
- |
4.2.5(Insulation : Tensile stregth variation ( After ageing) - IS 10810 (Part 7) ) |
- |
1250 |
|
- |
4.2.4(Insulation : Elongation (after ageing) - IS 10810 (Part 7) ) |
- |
1250 |
|
- |
4.2.5(Insulation : Elongation variation (after ageing) - IS 10810 (Part 7) ) |
- |
1250 |
|
- |
4.3(Fillers) |
- |
0 |
|
- |
4.4(Binder Tape) |
- |
0 |
|
- |
4.5.1,13.4, 14.4(Sheath : Compound ) |
- |
0 |
|
- |
4.5.2, 13.4, 14.4(Sheath : Application) |
- |
0 |
|
- |
4.5.3,13.4, 14.4(Thickness of sheath - Average : IS 10810 (Part 6)) |
- |
500 |
|
- |
4.5.3,13.4, 14.4(Thickness of sheath - Minimum : IS 10810 (Part 6)) |
- |
500 |
|
- |
4.5.4, 13.4(Sheath : Tensile stregth ( Before ageing)-IS 10810 (Part 7) ) |
- |
500 |
|
- |
4.5.4,13.4(Sheath : Elongation ( Before ageing) -IS 10810 (Part 7)) |
- |
500 |
|
- |
4.5.4, 13.4, 14.4(Sheath : Tensile stregth ( After ageing) - IS 10810 (Part 7) ) |
- |
1250 |
|
- |
4.5.5, 13.4, 14.4(Sheath : Tensile stregth variation ( After ageing) - IS 10810 (Part 7) ) |
- |
1250 |
|
- |
4.5.4, 13.4, 14.4(Sheath : Elongation (after ageing) - IS 10810 (Part 7) ) |
- |
1250 |
|
- |
4.5.5, 13.4,14.4(Sheath : Elongation variation (after ageing) - IS 10810 (Part 7) ) |
- |
1250 |
|
- |
4.5.5, 11.3, 12.3, 13.6, 14.6(Overall Dimensions) |
- |
0 |
|
- |
4.5.5.1, 11.3, 12.3,13.5, 14.5(Ovality) |
- |
0 |
|
- |
4.5.6, 13.4(Colour of Sheath) |
- |
0 |
|
- |
5.1(High Voltage Test (at Room Temperature)) |
- |
1500 |
|
- |
5.2(Spark Test (Routine Test)) |
- |
0 |
|
- |
5.3(Flammability Test- IS 10810 (Part 53).) |
- |
3000 |
|
- |
5.4(Oxygen Index Test- IS 10810 (Part 58)) |
- |
2500 |
|
- |
5.5(Temperature Index-IS 10810 (Part 64).) |
- |
2500 |
|
- |
5.6(Smoke Density-IS 10810 (Part 63).) |
- |
10000 |
|
- |
5.7(Assessment of Halogen- Table 1 of Annex D) |
- |
35000 |
|
- |
5.1(Persulphate Test- IS 10810 (Part 4).) |
- |
3000 |
|
- |
5.11(Flame Retardant Test- IS 10810 (Part 61),) |
- |
3000 |
|
- |
5.12(Hot Set Test- IS 10810 (Part 30).) |
- |
750 |
|
- |
5.12(Permanent Set - IS 10810 (Part 30).) |
- |
750 |
|
- |
5.13(Water Immersion Test (Effect of Water on Sheath) : Tensile strength -IS 10810 (Part 7).) |
- |
3000 |
|
- |
5.13(Water Immersion Test (Effect of Water on Sheath) : Elogation -IS 10810 (Part 7).) |
- |
3000 |
|
- |
5.14(Ozone Resistance Test -IS 10810 (Part 13 )) |
- |
10000 |
|
- |
5.15(Cold Bend Test-IS 10810 (Part 20).) |
- |
1500 |
|
- |
5.16(Cold Impact Test- IS 10810 (Part 21).) |
- |
1500 |
|
- |
6.1, Table 1(CORE IDENTIFICATION) |
- |
0 |
|
- |
6.2(Core Identification by Numbers) |
- |
0 |
|
- |
6.2.1(Preferred Arrangement of Marking) |
- |
0 |
|
- |
6.2.2(Durability) |
- |
0 |
|
- |
7.0(CABLE CODE) |
- |
0 |
|
- |
10.1(Packing ) |
- |
0 |
|
- |
10.2(marking) |
- |
0 |
|
- |
10.2.1(Standards marking) |
- |
0 |
|
- |
13.3, 14.3(assembly of cores ) |
- |
0 |
|
- |
6.1(General Requirements) |
- |
0 |
|
- |
6.1.1(Colour Combination Green Yellow) |
- |
0 |
|
- |
12.1(Conductor) |
- |
3500 |
|
- |
12.2, Table 4(insulation) |
- |
0 |
|
- |
|
Complete
|
|
16 Aug, 2024 |
- |
15 |
IS 8783 : Part 4 : Sec 2 (1995) |
Winding wires for submersible motors - specification: Part 4 specification for individual wires: Sec 2 crosslinked polyethylene insulated and polyamide jacketed wires (First Revision) |
- |
-
|
- View breakup
(Provisional testing charges):
Rs.13,800.00
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
No Record Found
|
|
Complete
|
|
16 Aug, 2024 |
- |
16 |
IS 694 (2010) |
Polyvinyl chloride insulated unsheathed and sheathed cables/cords with rigid and flexible conductor for rated voltages up to and including 450/750 v (Fourth Revision) |
- |
-
|
28500 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
13(Cable code) |
- |
0 |
|
- |
11.2(Legibility) |
- |
0 |
|
- |
11.1(Durability) |
- |
0 |
|
- |
11(Identification) |
- |
0 |
|
- |
10.9(Additional ageing test (OU cables only) -HV test (at 60±3oC)) |
- |
5000 |
|
- |
10.4(Flammability test- Unaffected portion) |
- |
500 |
|
- |
10.4(Flammability test-Burning after flame removal) |
- |
500 |
|
- |
table 1 e) 3) (IR constant- max. Temp) |
- |
100 |
|
- |
table 1 e) 3) (IR constant- Room temp ) |
- |
100 |
|
- |
table 1 e) 3) (Volume Resistivity - Maximum temp) |
- |
150 |
|
- |
table 1 e) 3) (Volume Resistivity - Room temp ) |
- |
150 |
|
- |
10.2(HV (room temperature)) |
- |
500 |
|
- |
10.1(HV (water immersion)) |
- |
300 |
|
- |
10.1(HV (water immersion)) |
- |
300 |
|
- |
10.8(Smoke density rating) |
- |
3000 |
|
- |
10.6(Halogen evolution) |
- |
3000 |
|
- |
10.7(Temperature index) |
- |
1500 |
|
- |
10.5(Oxygen index) |
- |
1500 |
|
- |
Table 1 iii) d) 9)(Cold impact for sheath) |
- |
500 |
|
- |
Table 1 iii) d) 8)(Cold bend for sheath) |
- |
500 |
|
- |
Table 1 iii) c) 9)(Cold impact for insulation) |
- |
750 |
|
- |
Table 1 iii) c) 8)(Cold bend for insulation) |
- |
750 |
|
- |
Table 1(Category Code) |
- |
0 |
|
- |
Table 1 iii) d) 7)(Thermal stability- Sheath ) |
- |
150 |
|
- |
Table 1 iii) c) 7)(Thermal stability- Insulation ) |
- |
150 |
|
- |
Table 1 iii) d) 6)(Hot deformation -Indentation depth - Sheath ) |
- |
150 |
|
- |
Table 1 iii) c) 6)(Hot deformation - Indentation depth- Insulation) |
- |
150 |
|
- |
Table 1 iii) d) 5)(Heat shock-Sheath ) |
- |
150 |
|
- |
Table 1 iii) c) 5)(Heat shock-Insulation ) |
- |
150 |
|
- |
Table 1 iii) d) 4)(Cracks Observed) |
- |
0 |
|
- |
Table 1 iii) d) 4)(Shrinkage- Sheath ) |
- |
150 |
|
- |
Table 1 iii) c) 4)(Cracks Observed) |
- |
0 |
|
- |
Table 1 iii) c) 4)(Shrinkage-Insulation) |
- |
150 |
|
- |
Table 1 iii) d) 2)(Loss of mass- Sheath ) |
- |
1000 |
|
- |
Table 1 iii) c) 2)(Loss of mass- Insulation ) |
- |
2000 |
|
- |
Table 1 iii) d) 3)(Sheath- Elongation variation) |
- |
0 |
|
- |
Table 1 iii) d) 3)(Sheath- TS variation) |
- |
0 |
|
- |
Table 1 iii) d) 3)(Sheath- Elongation (After ageing)) |
- |
750 |
|
- |
Table 1 iii) d) 3)(Sheath- Tensile strength (After ageing)) |
- |
750 |
|
- |
Table 1 iii) d) 1)(Sheath- Elongation (Without ageing)) |
- |
100 |
|
- |
Table 1 iii) d) 1)(Sheath -Tensile strength (Without ageing)) |
- |
100 |
|
- |
Table 1 iii) c) 3)(Elongation variation) |
- |
0 |
|
- |
Table 1 iii) c) 3)(TS variation) |
- |
0 |
|
- |
Table 1 iii) c) 3)(Elongation (After ageing)) |
- |
750 |
|
- |
Table 1 iii) c) 3)(Tensile strength (After ageing)) |
- |
750 |
|
- |
Table 1 iii) c) 1)(Elongation (Without ageing)) |
- |
150 |
|
- |
Table 1 iii) c) 1)(Tensile strength (Without ageing)) |
- |
150 |
|
- |
(Cl. 18.1.4)
(Cl. 19.1.5)
(Cl. 20.1.4)
(Cl. 22.1.4)(Colour of Sheath) |
- |
0 |
|
- |
8.3(Thickness of Sheath) |
- |
100 |
|
- |
5.2(Application ) |
- |
0 |
|
- |
5.3(Thickness of Insulation) |
- |
200 |
|
- |
9.1(Ovality) |
- |
100 |
|
- |
9(Overall dimensions) |
- |
100 |
|
- |
10.11(Per sulphate test (for tinned Cu cable only)) |
- |
400 |
|
- |
4.2(Conductor resistance test) |
- |
500 |
|
- |
4.1(Wrapping test (for Al)) |
- |
100 |
|
- |
4.1(Tensile test (for Al)- After Stranding) |
- |
100 |
|
- |
4.1(Tensile test (for Al)-Before Stranding) |
- |
100 |
|
- |
4.1(Annealing test (for copper)) |
- |
300 |
|
- |
(Cl.6.1.3 of IS 8130:2013)(Flexible Conductors (Classes 5)) |
- |
0 |
|
- |
(Cl.6.1.3 of IS 8130:2013)( Flexible Conductors (Classes 5)) |
- |
0 |
|
- |
(Cl.6.1.3 of IS 8130:2013)(Stranded circular non compacted conductors(Class-2)) |
- |
0 |
|
- |
(Cl.6.1.3 of IS 8130:2013)(Stranded compacted circular conductors and shaped conductors (Class 2)) |
- |
0 |
|
- |
(Cl.6.1.3 of IS 8130:2013)(Stranded circular non compacted conductors (Class-2)) |
- |
0 |
|
- |
(Cl.6.1.3 of IS 8130:2013)(Stranded circular non compacted conductors (Class-2)) |
- |
0 |
|
- |
(Cl.6.1.3 of IS 8130:2013)(Solid Conductor (Class 1)) |
- |
0 |
|
- |
(Cl.6.1 of IS 8130:2013)(Solid Conductor (Class 1)) |
- |
0 |
|
- |
(Cl.6.1 of IS 8130:2013)(Solid Conductor (Class 1)) |
- |
0 |
|
- |
(Cl.16.1)
(Cl.19.1)(Conductor- Diameter ) |
- |
0 |
|
- |
(Cl.16.1)
(Cl.19.1)(Conductor) |
- |
0 |
|
- |
(Cl.16.1)
(Cl.19.1)(Conductor) |
- |
0 |
|
- |
(Cl.16.1)
(Cl.19.1)(Conductor) |
- |
0 |
|
- |
(Cl. 18.1.3)
(Cl. 19.1.4)
(Cl. 20.1.3)
(Cl. 21.1.3)
(Cl. 22.1.3)(Assembly of cores ) |
- |
0 |
|
- |
12(CONSTRUCTION Core Identification) |
- |
0 |
|
- |
8.1(Sheath Material ) |
- |
0 |
|
- |
7(Binder Tape) |
- |
0 |
|
- |
6.2(Filler) |
- |
0 |
|
- |
6.1(Filler) |
- |
0 |
|
- |
5.1(Insulation) |
- |
0 |
|
- |
4.4(Joints in Conductor) |
- |
0 |
|
- |
4.4(Joints in Conductor) |
- |
0 |
|
- |
4.1(Conductor - Material) |
- |
0 |
|
- |
4.1(Conductor - Material) |
- |
0 |
|
- |
12.0(Core identification) |
- |
0 |
|
- |
4, IS 8130(Construction of conductor) |
- |
0 |
|
- |
Table 2, IS 8130(No fo wire in a conductor) |
- |
0 |
|
- |
8.3(Minimum thickness of Sheath) |
- |
0 |
|
- |
8.3(Avarage thickness of Sheath) |
- |
0 |
|
- |
5.3(Minimum thickness of insulation) |
- |
0 |
|
- |
5.3(Avarage thickness of insulation) |
- |
0 |
|
- |
|
Complete
|
|
16 Aug, 2024 |
- |
17 |
IS 4289 : Part 2 (2000) |
Flexible cables for lifts and other flexible connections - Specification: Part 2 pvc insulated circular cables |
- |
-
|
- View breakup
For BIS Samples: 1.5 times of BIS
Testing Charges.
For Others: Rs.25,000/-
Rs.2,000/- Each Additional Core
(10% discount to BIS)
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
No Record Found
|
|
Complete
|
|
16 Aug, 2024 |
- |
18 |
IS 9968 : Part 2 (2002) |
Specification for elastomer - Insulated cables: Part 2 for working voltages from 3.3 kV up to and including 33 kV (First Revision) |
- |
-
|
270000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
4.1(CONDUCTORS: Cables for Fixed Installation) |
- |
0 |
|
- |
4.2(CONDUCTORS:Flexible Cables) |
- |
0 |
|
- |
5(INSULATION) |
- |
0 |
|
- |
6(SEMICONDUCTING COMPOUND) |
- |
0 |
|
- |
7.1(Proofed Tape) |
- |
0 |
|
- |
7.1(Proofed Tape: Thickness) |
- |
500 |
|
- |
7.2(Polyethylene Terephthalate ( P E T P ) or
Polypropylene Base Tape : Thickness) |
- |
500 |
|
- |
7.3(Tape ) |
- |
0 |
|
- |
8(SCREENING) |
- |
0 |
|
- |
9(CENTRE AND FILLERS) |
- |
0 |
|
- |
10(ARMOUR) |
- |
0 |
|
- |
11.1(Inner Sheath) |
- |
0 |
|
- |
11.2(Outer Sheath) |
- |
0 |
|
- |
12.1(Tapes) |
- |
0 |
|
- |
12.2(Cords and Yarns) |
- |
0 |
|
- |
13.1 & 13.2(CONSTRUCTION:CONDUCTORS-Cables for Fixed Installations/Flexible Cables) |
- |
0 |
|
- |
13.3(Earthing Conductor) |
- |
0 |
|
- |
13.3.1(Earthing Conductor) |
- |
0 |
|
- |
13.4(Separator Tape) |
- |
0 |
|
- |
14(CONDUCTOR SCREENING) |
- |
0 |
|
- |
15.1(INSULATION : Application) |
- |
0 |
|
- |
15.2(Thickness of Insulation) |
- |
500 |
|
- |
15.3(Tolerance on Thickness of Insulation) |
- |
0 |
|
- |
16.1(INSULATION SCREENING : Application) |
- |
0 |
|
- |
16.2(INSULATION SCREENING : Parts ) |
- |
0 |
|
- |
16.3(INSULATION SCREENING : Non Metallic Parts ) |
- |
0 |
|
- |
16.4(INSULATION SCREENING : Metallic Parts ) |
- |
0 |
|
- |
17(CORE IDENTIFICATION) |
- |
0 |
|
- |
17(CORE IDENTIFICATION: Unscreed cable ) |
- |
0 |
|
- |
18.1(LAYING UP OF CORES) |
- |
0 |
|
- |
18.2(LAYING UP OF CORES : Flexible cable) |
- |
0 |
|
- |
18.3(LAYING UP OF CORES : Binder Tape) |
- |
0 |
|
- |
19.1(Inner Sheath : Application) |
- |
0 |
|
- |
19.2(Thickness of Inner Sheath) |
- |
500 |
|
- |
19.3(Inner Sheath : proofed tape) |
- |
0 |
|
- |
20.1(ARMOURING: Application) |
- |
0 |
|
- |
20.2(Type of Armour) |
- |
0 |
|
- |
20.2 1.2(Direction of lay of armour) |
- |
0 |
|
- |
20.2 1.3(Joint in armour) |
- |
0 |
|
- |
20.2.2(Filling Factot ) |
- |
0 |
|
- |
20.2.2(Diameter of braiding) |
- |
500 |
|
- |
20.2.2.1(Braiding material) |
- |
0 |
|
- |
20.3(Substitution of the galvanized steel wires/formed) |
- |
0 |
|
- |
21.1(OUTER SHEATH) |
- |
0 |
|
- |
21.2(Coulor of Outer sheath) |
- |
0 |
|
- |
21.3(Thickness of Outer Sheat: Average) |
- |
500 |
|
- |
21.3(Thickness of Outer Sheat: Minimum) |
- |
0 |
|
- |
22.1 a)1)(Annealing test
(for copper) - IS 10810: Part 1) |
- |
1200 |
|
- |
22.1 a)2)(Tensile test
(for aluminium) -IS 10810: Part 2) |
- |
1000 |
|
- |
22.1 a)3)(Wrapping Test
(for aluminium) - IS 10810: Part 3) |
- |
500 |
|
- |
22.1 a)4)(Conductor resistance
test) |
- |
1000 |
|
- |
22.1 a)5)(Persulphate test
(tinned copper
conductor)- IS 10810: Part 4) |
- |
1200 |
|
- |
22.1 b)1)(Test for Galvanized Steel
Wires/Formed Wires
1) Dimensions -IS 10810: Part 36) |
- |
700 |
|
- |
22.1 b)2)i)(Test for Galvanized Steel
Wires/Formed Wires
2) Tensile Strentgh -IS 10810: Part 37) |
- |
500 |
|
- |
22.1 b)2)ii)(Test for Galvanized Steel
Wires/Formed Wires
2) Elongation at break -IS 10810: Part 37) |
- |
500 |
|
- |
22.1 b)2)iii)(Test for Galvanized Steel
Wires/Formed Wires
3) Torsion (for round
wires only) -IS 10810: Part 38) |
- |
1500 |
|
- |
22.1 b)2)iv)(Test for Galvanized Steel
Wires/Formed Wires
4) Winding (for strips
only) -IS 10810: Part 39) |
- |
1500 |
|
- |
22.1 b)2)v)(Test for Galvanized Steel
Wires/Formed Wires
5) Zinc coating : Uniformity-IS 10810: Part 40) |
- |
500 |
|
- |
22.1 b)2)vi)(Test for Galvanized Steel
Wires/Formed Wires
5) Zinc coating : Mass -IS 10810: Part 41) |
- |
1000 |
|
- |
22.1 b)2) vii) (Resistivity - IS 10810: Part 42) |
- |
1000 |
|
- |
22.1 c)2)(Physical Tests for
Insulation : Tensile Strenth - IS 10810: Part 7) |
- |
500 |
|
- |
22.1 c)2)(Physical Tests for
Insulation : Elongation - IS 10810: Part 7) |
- |
500 |
|
- |
22.1 c)2)(Physical Tests for
Sheath : Tensile Strenth - IS 10810: Part 7) |
- |
500 |
|
- |
22.1 c)2)(Physical Tests for
Sheath : Elongation - IS 10810: Part 7) |
- |
500 |
|
- |
22.1 c)3)(Physical Tests for
Insulation ( Ageing in air oven): Tensile Strenth - IS 10810: Part 11) |
- |
1250 |
|
- |
22.1 c)3)(Physical Tests for
Insulation ( Ageing in air oven): Tensile Strenth Variation - IS 10810: Part 12) |
- |
0 |
|
- |
22.1 c)3)(Physical Tests for
Insulation( Ageing in air oven) : Elongation - IS 10810: Part 11) |
- |
1250 |
|
- |
22.1 c)3)(Physical Tests for
Insulation( Ageing in air oven) : Elongation variation - IS 10810: Part 12) |
- |
0 |
|
- |
22.1 c)3)(Physical Tests for
Sheath( Ageing in air oven) : Tensile Strenth - IS 10810: Part 11) |
- |
1250 |
|
- |
22.1 c)3)(Physical Tests for
Sheath( Ageing in air oven) : Tensile Strenth variation - IS 10810: Part 12) |
- |
0 |
|
- |
22.1 c)3)(Physical Tests for
Sheath ( Ageing in air oven): Elongation - IS 10810: Part 11) |
- |
1250 |
|
- |
22.1 c)3)(Physical Tests for
Sheath ( Ageing in air oven): Elongation variation - IS 10810: Part 12) |
- |
0 |
|
- |
22.1 c)4)(Physical Tests for
Insulation ( Ageing in air bomb): Tensile Strenth variation - IS 10810: Part 56) |
- |
2500 |
|
- |
22.1 c)4)(Physical Tests for
Insulation( Ageing in air bomb) : Elongation variation - IS 10810: Part 56) |
- |
2500 |
|
- |
22.1 c)4)(Physical Tests for
Sheath(Ageing in air bomb) : Tensile Strenth variation - IS 10810: Part 56) |
- |
2500 |
|
- |
22.1 c)4)(Physical Tests for
Sheath ( Ageing in air bomb): Elongation variation - IS 10810: Part 56) |
- |
2500 |
|
- |
22.1 c)5)(Physical Tests for
Insulation :Hot set Elongation - IS 10810: Part 30) |
- |
1000 |
|
- |
22.1 c)5)(Physical Tests for
Insulation :Permanent set - IS 10810: Part 30) |
- |
500 |
|
- |
22.1 c)5)(Physical Tests for
Sheath :Hot set Elongation - IS 10810: Part 30) |
- |
1000 |
|
- |
22.1 c)5)(Physical Tests for
Sheath :Permanent set - IS 10810: Part 30) |
- |
500 |
|
- |
22.1 c)6)(Physical Tests for
Sheath(Oil resistance test) : Tensile Strenth Variation - IS 10810: Part 31) |
- |
2250 |
|
- |
22.1 c)6)(Physical Tests for
Sheath ( Oil resistance test): Elongation Variation - IS 10810: Part 31) |
- |
2250 |
|
- |
22.1 c)7)(Tear Resistance test - IS 10810: Part 17) |
- |
5400 |
|
- |
22.1 c)8)(Shrinkage : Insulation - IS 10810: Part 12) |
- |
1000 |
|
- |
22.1 c)8)(Shrinkage test- Crack observed : Insulation - IS 10810: Part 13) |
- |
500 |
|
- |
22.1 c)8)(Shrinkage test : Sheath - IS 10810: Part 12) |
- |
1000 |
|
- |
22.1 c)8)(Shrinkage test - Crack oberved : Sheath - IS 10810: Part 13) |
- |
500 |
|
- |
22.1 c)9)(Hot deformation test : Insulation - IS 10810: Part 15) |
- |
1500 |
|
- |
22.1 c)9)(Hot deformation test : Sheath - IS 10810: Part 15) |
- |
1500 |
|
- |
22.1 c)10)(Loss of mass in air
oven : Insulation - IS 10810: Part 10) |
- |
2500 |
|
- |
22.1 c)10)(Loss of mass in air
oven : Sheath - IS 10810: Part 10) |
- |
2500 |
|
- |
22.1 c)11)(Heat shock : Insulation - IS 10810: Part 14) |
- |
1500 |
|
- |
22.1 c)11)(Heat shock : Sheath - IS 10810: Part 14) |
- |
1500 |
|
- |
22.1 c)12)(Thermal stability : Insulation - IS 10810: Part 60) |
- |
1000 |
|
- |
22.1 c)12)(Thermal stability : Sheath - IS 10810: Part 60) |
- |
1000 |
|
- |
22.1 d)(Insulation Resistance Test: Volume resistivity ) |
- |
1500 |
|
- |
22.1 d)(Insulation Resistance Test: Insulation resistance constant ) |
- |
1000 |
|
- |
22.1 e)(Partial Discharge Test) |
- |
42500 |
|
- |
22.1 f)(Bending Test Followed by
Partial Discharge Test) |
- |
4500 |
|
- |
22.1 g)(Dielectric Power Factor
Test
1) As a function of Voltage) |
- |
7500 |
|
- |
22.1 g)(Dielectric Power Factor
Test
1) As a function of
temperature) |
- |
7500 |
|
- |
22.1 h)(Heating Cycle Test) |
- |
35500 |
|
- |
22.1 j)(Impulse Withstand Test) |
- |
35500 |
|
- |
22.1 k)(High Voltage Test
for Four Hours) |
- |
7500 |
|
- |
22.1 m)(Water Absorption Test - IS 10810: Part 28) |
- |
4500 |
|
- |
22.1 n)(Flammability) |
- |
3000 |
|
- |
24.1(Manufacturer's Identification) |
- |
0 |
|
- |
24.2(Voltage Identification) |
- |
0 |
|
- |
24.3(Cable Code) |
- |
0 |
|
- |
25.2.1(Marking on drum ) |
- |
0 |
|
- |
25.2.2(BIS Certification Marking) |
- |
0 |
|
- |
|
Complete
|
|
16 Aug, 2024 |
- |
19 |
IS 14494 (2019) |
Elastomer insulated flexible cables for use in mines - Specification (First Revision) |
- |
-
|
287000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
4(CONDUCTOR) |
- |
0 |
|
- |
5(INSULATION) |
- |
0 |
|
- |
5.1(Power Cores) |
- |
0 |
|
- |
5.2(Pilot and Earth Cores) |
- |
0 |
|
- |
6(SEMI-CONDUCTING COMPOUND) |
- |
0 |
|
- |
7.1(TAPE : Proofed Tape) |
- |
0 |
|
- |
7.2(TAPE : Polyethylene Terephalate (PETP) or
Polypropylene Base Tape) |
- |
0 |
|
- |
7.3(TAPE ) |
- |
0 |
|
- |
8(CENTRE) |
- |
0 |
|
- |
9.1(FILLERS) |
- |
0 |
|
- |
9.2(FILLERS) |
- |
0 |
|
- |
10(CRADLE SEPARATOR) |
- |
0 |
|
- |
11.1(ARMOUR) |
- |
0 |
|
- |
11.2(ARMOUR) |
- |
0 |
|
- |
11.2 a)(ARMOURING: Tensile Strength) |
- |
500 |
|
- |
11.2 b)(ARMOURING: Elongation ) |
- |
500 |
|
- |
11.2 c)(ARMOURING: Torsion Test (For round wire ) ) |
- |
1000 |
|
- |
11.2 d)(ARMOURING: Uniformity of zinc coating) |
- |
1000 |
|
- |
11.2 e)(ARMOURING: Mass of zinc coating ) |
- |
1000 |
|
- |
12.1(SHEATH : Inner Sheath) |
- |
0 |
|
- |
12.2(SHEATH : Outer Sheath) |
- |
0 |
|
- |
13.1(REINFORCEMENT MATERIAL : Tape) |
- |
0 |
|
- |
13.2(REINFORCEMENT MATERIAL : Cord/Yarns) |
- |
0 |
|
- |
14.1(CONSTRUCTION : CONDUCTOR) |
- |
0 |
|
- |
14.2(CONSTRUCTION : CONDUCTOR) |
- |
0 |
|
- |
14.3(CONSTRUCTION : CONDUCTOR) |
- |
0 |
|
- |
14.4(CONSTRUCTION : CONDUCTOR) |
- |
0 |
|
- |
15(CONDUCTOR SCREENING) |
- |
0 |
|
- |
16.1(INSULATION) |
- |
0 |
|
- |
16.2(INSULATION : Thickness of Insulation) |
- |
500 |
|
- |
16.3(INSULATION : Tolerance on Insulation Thickness) |
- |
0 |
|
- |
16.4(INSULATION : Application of Insulation) |
- |
0 |
|
- |
16.5(INSULATION) |
- |
0 |
|
- |
17.1(INSULATION SCREEN) |
- |
0 |
|
- |
17.2(INSULATION SCREEN) |
- |
0 |
|
- |
17.3(INSULATION SCREEN) |
- |
0 |
|
- |
17.4(INSULATION SCREEN) |
- |
0 |
|
- |
18(PROTECTIVE SCREEN) |
- |
0 |
|
- |
19(CONDUCTANCE OF SCREEN) |
- |
0 |
|
- |
19.1(Individual Core Screen) |
- |
0 |
|
- |
19.2(Collective Screen) |
- |
0 |
|
- |
20.1(CORE IDENTIFICATION) |
- |
0 |
|
- |
20.2(Colour Scheme for Identification) |
- |
0 |
|
- |
20.3(Scheme for Identification by Numbering) |
- |
0 |
|
- |
21.1(LAYING UP OF CORES) |
- |
0 |
|
- |
21.2(LAYING UP OF CORES) |
- |
0 |
|
- |
21.3(LAYING UP OF CORES) |
- |
0 |
|
- |
21.4(LAYING UP OF CORES) |
- |
0 |
|
- |
22.1(INNER SHEATH) |
- |
0 |
|
- |
22.2(Thickness of Inner Sheath) |
- |
500 |
|
- |
22.3(INNER SHEATH) |
- |
0 |
|
- |
23.1(ARMOURING) |
- |
0 |
|
- |
23.2(ARMOURING) |
- |
0 |
|
- |
23.3(ARMOURING) |
- |
0 |
|
- |
23.4(ARMOURING) |
- |
0 |
|
- |
24.1(OUTER SHEATH) |
- |
0 |
|
- |
24.2(Thickness of Outer Sheath) |
- |
500 |
|
- |
24.3(Tolerance on Thickness of Outer Sheath) |
- |
0 |
|
- |
24.4(OUTER SHEATH) |
- |
0 |
|
- |
25.1(CABLE CONSTRUCTION AND DIMENSIONS) |
- |
500 |
|
- |
27.2(Bending test followed by partial discharge test;) |
- |
5000 |
|
- |
27.4(Dielectric power factor test) |
- |
15000 |
|
- |
27.5(Heating cycle test followed by partial discharge test;) |
- |
45000 |
|
- |
27.6(Impulse voltage test; and) |
- |
65000 |
|
- |
26.3(Special Provisions) |
- |
0 |
|
- |
27.8(Flammability Test) |
- |
3000 |
|
- |
27.9(Water Absorption Test) |
- |
12000 |
|
- |
28(IDENTIFICATION) |
- |
0 |
|
- |
29.1(PACKING AND MARKING) |
- |
0 |
|
- |
29.2(PACKING AND MARKING) |
- |
0 |
|
- |
30(BIS CERTIFICATION MARKING) |
- |
0 |
|
- |
|
Complete
|
|
16 Aug, 2024 |
- |
20 |
IS 4289 : Part 1 (1984) |
Specification for flexible cables for lifts and other flexible connections: Part 1 elastomer insulated cables (First Revision) |
- |
-
|
- View breakup
For BIS Samples: 1.5 times of BIS
Testing Charges.
For Others: Rs.35,000/-
Rs.2,000/- Each Additional Core
(10% discount to BIS)
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
No Record Found
|
|
Complete
|
|
16 Aug, 2024 |
- |
21 |
IS 9968 : Part 1 (1988) |
Specification for elastomer insulatedcables: Part 1 for working voltages up to and including 1100 volts (First Revision) |
- |
-
|
51500 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
3.1( Copper Cooduetor) |
- |
0 |
|
- |
3.2(Aluminium conductor) |
- |
0 |
|
- |
4.1(INSULATION : lnsulation for General Service) |
- |
0 |
|
- |
4.2(INSULATION : Heat Resisting insulation) |
- |
0 |
|
- |
4.3(INSULATION : Silicone Rubber Insulation) |
- |
0 |
|
- |
5.1(TAPE : Proofed Tape) |
- |
0 |
|
- |
5.2(TAPE : 2 Polyethyl_ Terephthalate ( PETP ) Tape or
Plastic: Tape or Any Other SlIIitable Tape ) |
- |
0 |
|
- |
5.3(TAPE : Giass Tape) |
- |
0 |
|
- |
6.1(FILLERS : ) |
- |
0 |
|
- |
7.1(BRAID : Textile Braid) |
- |
0 |
|
- |
7.2(BRAID : Glass Braid ) |
- |
0 |
|
- |
8.1(SHEATH : General Service Insulated Cables and Flexible
Cords) |
- |
0 |
|
- |
8.2(SHEATH :Heat Resisting Insulated Cables) |
- |
0 |
|
- |
9.1(PresenRtive Compound) |
- |
0 |
|
- |
9.2(Varnish) |
- |
0 |
|
- |
10( Conductor ) |
- |
0 |
|
- |
11(Separator tape) |
- |
0 |
|
- |
12.2(Insulation : Thickness of Insufatien) |
- |
500 |
|
- |
12.4(Insulation : Allplication of Insulation) |
- |
0 |
|
- |
13(CORE IDENTiFICATlON) |
- |
0 |
|
- |
14(Tape) |
- |
0 |
|
- |
15(BRAIDING) |
- |
0 |
|
- |
16(COMPOUNDING AND VARNISHING) |
- |
0 |
|
- |
17(LAYING UP OF CORES) |
- |
0 |
|
- |
18( Binder tape) |
- |
0 |
|
- |
19.2(Sheath : Thickness of Sheath) |
- |
500 |
|
- |
19.4( Sheath :Colour) |
- |
0 |
|
- |
20( Overall diameter) |
- |
500 |
|
- |
21. (a)(Persulphate tests (for copper)) |
- |
1200 |
|
- |
21. (b)(Annealing Test (for coper)) |
- |
1200 |
|
- |
21. (c)( Tensile Test (for aluminium)) |
- |
1000 |
|
- |
21. (d)( Wrapping Test (for aluminium)) |
- |
500 |
|
- |
21. (e)(Conductor Resistance ) |
- |
1000 |
|
- |
21.1( Tensile strength ) |
- |
2500 |
|
- |
22.1( Elongation) |
- |
2500 |
|
- |
21.1(type test : Ageing In air oven) |
- |
5000 |
|
- |
21.1(type test : Ageing in air bomb) |
- |
6000 |
|
- |
21.1(type test : Ageing In oxygen
bomb) |
- |
12000 |
|
- |
21.1(type test : Hot set elongation) |
- |
1500 |
|
- |
21.1(type test : Tear resistance ) |
- |
5400 |
|
- |
22.2(type test :Insulauon resistance High voltage (water immersron ) test) |
- |
2000 |
|
- |
22.2(type test : Flammability test
( applicable to cables
finished With SE 3 and
SE 4 sheaths only)
) |
- |
3000 |
|
- |
21(Water absorption test) |
- |
3500 |
|
- |
23(identification) |
- |
0 |
|
- |
|
Complete
|
|
16 Aug, 2024 |
- |
22 |
IS 9857 (1990) |
Welding cables - Specification (First Revision) |
- |
-
|
10000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
4(Conductor : Material ) |
- |
0 |
|
- |
5(SEPARATOR) |
- |
0 |
|
- |
6(COVERING) |
- |
0 |
|
- |
7(CONDUCTOR : CONSTRUCTION ) |
- |
0 |
|
- |
8(S E P A R A T O R) |
- |
0 |
|
- |
9.1(C O V E R I N G : Application ) |
- |
0 |
|
- |
9.2(T h i c k n e s s o f C o v e r i n g) |
- |
0 |
|
- |
9.3(T o l e r a n c e on Thickness o f C o v e r i n g) |
- |
0 |
|
- |
9.4(A p p l i c a t i o n of C o v e r i n g) |
- |
0 |
|
- |
9.5(Colour of C o v e r i n g) |
- |
0 |
|
- |
10.1 a) 1)(Annealing test - IS 10810: Part 1) |
- |
1000 |
|
- |
10.1 a) 2)(Conductor resistance tes - IS 10810 : Part 5) |
- |
500 |
|
- |
10.1 c) 1)(Physical tests for
covering : Tensile strength ) |
- |
500 |
|
- |
10.1 c) 1)(Physical tests for
covering : Elongation at break ) |
- |
500 |
|
- |
10.1 c) 2)(Physical tests for
covering - Ageing in Air oven : Tensile strength variation) |
- |
500 |
|
- |
10.1 c) 2)(Physical tests for
covering -Ageing in Air oven : Elongation at break ) |
- |
500 |
|
- |
10.1 c) 2)(Physical tests for
covering - Ageing in Air oven : Tensile strength ) |
- |
500 |
|
- |
10.1 c) 2)(Physical tests for
covering -Ageing in Air oven : Elongation variation at break ) |
- |
500 |
|
- |
10.1 c) 3)(Physical tests for
covering - Ageing in Air Bomb : Tensile strength variation ) |
- |
500 |
|
- |
10.1 c) 3)(Physical tests for
covering -Ageing in Air Bomb : Elongation variation at break ) |
- |
500 |
|
- |
10.1 c) 4)(Physical tests for
covering - Oil Resistance : Tensile strength variation ) |
- |
750 |
|
- |
10.1 c) 4)(Physical tests for
covering - Oil Resistance : Elongation variation at break ) |
- |
750 |
|
- |
10.1 c) 5)(Hot set test ) |
- |
300 |
|
- |
10.1 c) 5)(Permanent set ) |
- |
200 |
|
- |
11.1(High Voltage Test ( Water Immersion
Test )) |
- |
1000 |
|
- |
11.2(Spark Test) |
- |
500 |
|
- |
11.3(Static Flexibility Test) |
- |
1000 |
|
- |
11.4(Flammability Test) |
- |
1000 |
|
- |
12.1(Manufacturer's Identification) |
- |
0 |
|
- |
12.2(Cable Identification) |
- |
0 |
|
- |
12.3(Cable Code) |
- |
0 |
|
- |
13.1(Packing ) |
- |
0 |
|
- |
13.2(Marking) |
- |
0 |
|
- |
14(CABLE RATINGS) |
- |
0 |
|
- |
15(VOLTAGE DROP) |
- |
0 |
|
- |
|
Complete
|
|
16 Aug, 2024 |
- |
23 |
IS 8783 : Part 1 (1995) |
Winding wires for submersible motors - Specification: Part 1 conductor data (First Revision) |
- |
-
|
- View breakup
(Provisional testing charges):
Rs.13,800.00
(10% discount to BIS)
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
No Record Found
|
|
Complete
|
|
16 Aug, 2024 |
- |
24 |
IS 8783 : Part 2 (1995) |
Winding wires for submersible motors - Specification: Part 2 materials for dielectric and jacket (First Revision) |
- |
-
|
- View breakup
(Provisional testing charges):
Rs.13,800.00
(10% discount to BIS)
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
No Record Found
|
|
Complete
|
|
16 Aug, 2024 |
- |
25 |
IS 14255 (1995) |
Aertal bunched cables - For working voltages up to and including 1100 Volts - Specification |
- |
-
|
25000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
4.1(Phase/Street Lighting conductor) |
- |
0 |
|
- |
4.2(Messenger (Neutral Conductor or Otherwise)) |
- |
0 |
|
- |
5.1(Insulation) |
- |
0 |
|
- |
6.1(Flexibility class) |
- |
0 |
|
- |
6.2(Compactness) |
- |
0 |
|
- |
6.2(No of strands) |
- |
0 |
|
- |
6.2(Surface) |
- |
0 |
|
- |
6.3(Protective barrier) |
- |
0 |
|
- |
6.4(size of street lighting conductor) |
- |
0 |
|
- |
6.5(Size of messenger conductor ) |
- |
0 |
|
- |
6.6(Joints in messenger conductor ) |
- |
0 |
|
- |
6.6(Direction of outer layer) |
- |
0 |
|
- |
7.1(Insulation) |
- |
0 |
|
- |
7.2( Thickness of insulation) |
- |
500 |
|
- |
7.3(Tolerance on thickness of insulation ) |
- |
0 |
|
- |
7.4(Aplication of the insulation ) |
- |
0 |
|
- |
7.5(Colour of the insulation ) |
- |
0 |
|
- |
8.1(Core identification) |
- |
0 |
|
- |
8.2(Core identification) |
- |
0 |
|
- |
8.3(Identification by other means) |
- |
0 |
|
- |
9.1(Assembly (Laying up)) |
- |
0 |
|
- |
9.2(Assembly (Laying up)) |
- |
0 |
|
- |
9.3(Direction of lay) |
- |
0 |
|
- |
10.1 a) i)(Tests on phase/street light conductor: tensile test - Test method IS10810:Part 2) |
- |
300 |
|
- |
10.1 a) ii)(Wrapping test - 10810: Part 3) |
- |
200 |
|
- |
10.1 a) iii)(Resistance test - IS10810: Part 5) |
- |
500 |
|
- |
10.1 b) i)(Test on messenger conductor: Breaking load - IS 10810: Part 2) |
- |
750 |
|
- |
10.1 b) ii)(Test on messenger conductor: Elongation test - Cl 11.3) |
- |
750 |
|
- |
10.1 b) iii)(Test on messenger conductor: Resistance test - IS 10810: Part 5) |
- |
500 |
|
- |
10.1 c) i)(Physical tests for XLPE Insulation:
Tensile strength - IS 10810: Part 7) |
- |
250 |
|
- |
10.1 c) i)(Physical tests for XLPE Insulation:
elongation at break - IS 10810: part 7) |
- |
250 |
|
- |
10.1 c) ii)(Ageing in air oven : Tensile strength variation - IS 10810:Part 11) |
- |
1750 |
|
- |
10.1 c) ii)(Ageing in air oven : Elongation variation- IS 10810: Part 11) |
- |
1750 |
|
- |
10.1 c) iii)(Hot set test: Elongation under load - IS 10810: Part 30) |
- |
500 |
|
- |
10.1 c) iii)(Hot set test: Permanent elongation (set) after cooling - IS 10810: Part 30) |
- |
500 |
|
- |
10.1 c) iv)(Shrinkage test : Shrinkage - 10810:Part 12) |
- |
400 |
|
- |
10.1 c) iv)(Shrinkage test : Crack Observed - 10810:Part 12) |
- |
100 |
|
- |
10.1 c) v)(Water ahsorption (Gravimetric) - IS 10810: Part 33 ) |
- |
3000 |
|
- |
10.1 d) i)(Physical test for PE insulation:
Tensile strength - IS 10810: Part 7 ) |
- |
2500 |
|
- |
10.1 d) i)(Physical test for PE insulation: elongation at break - IS 10810: Part 7) |
- |
2500 |
|
- |
10.1 d) ii)(Melt flow index- IS 10810: Part 23) |
- |
2000 |
|
- |
10.1 d) iv)(Vicat softening point -IS 10810: Part 22) |
- |
1000 |
|
- |
10.1 d) v)(Environmental stress cracking -IS 10810:Part29) |
- |
3000 |
|
- |
10.1 f)(Insulation resistance (Volume resistivity) test a) volume resistivity at 27°C - IS 10810: Part 43) |
- |
500 |
|
- |
10.1 f)(Insulation resistance (Volume resistivity) test b) volume resistivity at 70°C - IS 10810: Part 43) |
- |
500 |
|
- |
10.1 g)(High voltage test - IS10810:Part 45) |
- |
1000 |
|
- |
11.4(Bending Test on the Completed Cable ( Optional) ) |
- |
1000 |
|
- |
|
Complete
|
|
16 Aug, 2024 |
- |
26 |
IS 398 : Part 2 (1996) |
Aluminium conductors for overhead transmission purposes - Specification: Part 2 aluminium conuuctors, galvanized steel - Reinforced (Third Revision) |
- |
-
|
12500 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
8.1.1 & 13.2 Table-1 (mech)(Diameter of Aluminium Wires Before Stranding) |
- |
250 |
|
- |
8.1.1 & 13.2 Table 2 (mech)(Diameter of Steel Wires Before Stranding) |
- |
250 |
|
- |
8.1.1 & 13.2 Table-1 (mech)(Diameter of Aluminium Wires After Stranding) |
- |
250 |
|
- |
8.1.1 & 13.2 Table 2 (mech)(Diameter of Steel Wires After Stranding) |
- |
250 |
|
- |
10 (elec)(Stranding) |
- |
0 |
|
- |
13.3 Table 1 (mech)(Breaking Load of Aluminium Wires Before Stranding) |
- |
500 |
|
- |
13.3 Table 2 (mech)(Breaking Load of Steel Wires Before Stranding) |
- |
500 |
|
- |
13.3 Table 1 (mech)(Breaking Load of Aluminium Wires After Stranding) |
- |
500 |
|
- |
13.3 Table 2 (mech)(Breaking Load of Steel Wires After Stranding) |
- |
500 |
|
- |
13.4.1 (mech)(Ductility by Torsion Test before stranding) |
- |
500 |
|
- |
13.4.1 (mech)(Ductility by Torsion Test before stranding) |
- |
500 |
|
- |
13.4.1 (mech)(Ductility by Torsion Test after stranding) |
- |
500 |
|
- |
13.4.1 (mech)(Ductility by Torsion Test after stranding) |
- |
500 |
|
- |
13.4.2 (elec)(Ductility by Elongation Test before stranding) |
- |
500 |
|
- |
13.4.2 (elec)(Ductility by Elongation Test after stranding) |
- |
500 |
|
- |
13.5.1 (mech)(Wrapping Test Aluminium Wires Before Stranding) |
- |
250 |
|
- |
13.5.1 (mech)(Wrapping Test Aluminium Wires After Stranding) |
- |
250 |
|
- |
13.5.2 (mech)(Wrapping Test Galvanized Steel Wires Before Stranding) |
- |
250 |
|
- |
13.5.2 (mech)(Wrapping Test Galvanized Steel Wires After Stranding) |
- |
250 |
|
- |
13.6 (elec)(Resistance test-Aluminium wire before Stranding) |
- |
1000 |
|
- |
13.6 (elec)(Resistance test-Aluminium wire after stranding) |
- |
1000 |
|
- |
13.7.2 (chem)(Mass of Zinc coating) |
- |
1000 |
|
- |
13.7.2 (chem)(Uniformity of Zinc coating) |
- |
1000 |
|
- |
13.8 Table-4 (mech)(Lay Ratio- Aluminium Wire Outermost Layer) |
- |
500 |
|
- |
13.8 Table-4 (mech)(Lay Ratio- Aluminium Wire Layer Immediately Beneath Outermost Layer) |
- |
500 |
|
- |
13.8 Table-4 (mech)(Lay Ratio- Aluminium Wire Innermost Layer of Conductors with 3 Aluminium Wire Layers) |
- |
500 |
|
- |
13.8 Table-4 (mech)(Lay Ratio- Steel Core (6 Wire Layer)) |
- |
500 |
|
- |
13.9 (elec)(Surface condition test) |
- |
0 |
|
- |
13.10 (elec)(Ultimate breaking load) |
- |
500 |
|
- |
13.11 (elec)(Stress-strain test) |
- |
1500 |
|
- |
|
Complete
|
|
16 Aug, 2024 |
- |
27 |
IS 398 : Part 1 (1996) |
Aluminium conductors for overhead transmission purposes - Specification: Part 1 aluminium stranded conductors (Third Revision) |
- |
-
|
5625 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
12.2, Table-1(Measurement of diameter of individual aluminium wire) |
- |
1500 |
|
- |
12.3, Table-1(Breaking load before stranding) |
- |
1250 |
|
- |
12.3, Table-1(Breaking load after stranding) |
- |
1250 |
|
- |
12.4(Wrapping test) |
- |
1500 |
|
- |
12.5, Table 1(Resistance test) |
- |
3500 |
|
- |
12.6, Table 3(Measurement of lay ratio) |
- |
1500 |
|
- |
9.3(Stranding) |
- |
0 |
|
- |
6(Freedom from defects) |
- |
0 |
|
- |
|
Complete
|
|
16 Aug, 2024 |
- |