1 |
IS 16333 : Part 3 (2017) |
Mobile phone handsets: Part 3 indian language support for mobile phone handsets - Specific requirements (First Revision) |
- |
-
|
15000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
5.1(Inputting of text) |
- |
7500 |
|
- |
5.2(Message Readability) |
- |
7500 |
|
- |
|
Complete
|
|
- |
- |
2 |
IS 16242 : Part 1 (2014) |
Uninterruptible power systems (UPS): Part 1 general and safety requirements for UPS |
- |
-
|
65000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
4.6(Power interface) |
- |
5000 |
|
Rs. 65000 for upto 5kVA;
Rs. 80,000 for upto 10kVA. |
4.7(Marking & instructions) |
- |
1000 |
|
- |
5.1(Protection against shock and energy hazards) |
- |
5000 |
|
- |
5.2(Requirement of auxiliary circuits) |
- |
4000 |
|
- |
5.3(Protective earthing and bonding) |
- |
2000 |
|
- |
5.5(Over current and earth fault condition) |
- |
3000 |
|
- |
5.6(Safety interlocks) |
- |
2000 |
|
- |
5.7(CLEARANCES, CREEPAGE DISTANCES AND SOLID INSULATION) |
- |
5000 |
|
- |
6.1(Wiring, connections and supply) |
- |
1000 |
|
- |
6.2(Connection to power) |
- |
3000 |
|
- |
6.3(Wiring terminals for external power conductors) |
- |
3000 |
|
- |
7.2(STABILITY) |
- |
5000 |
|
- |
7.3(MECHANICAL STRENGTH) |
- |
3000 |
|
- |
7.4(Construction details) |
- |
4000 |
|
- |
7.5(Resistance to fire) |
- |
3000 |
|
- |
7.6(Battery location) |
- |
5000 |
|
- |
7.7(Temperature rise) |
- |
6000 |
|
- |
8.2(Electric Strength) |
- |
3000 |
|
- |
8.3(Abnormal operating and fault conditions) |
- |
5000 |
|
- |
9.0(Connection to telecommunication networks) |
- |
5000 |
|
- |
5.4(AC and DC power isolation) |
- |
2000 |
|
- |
7.1(Enclosure) |
- |
2000 |
|
- |
8.1(General procision for earth leakage) |
- |
3000 |
|
- |
|
Complete
|
|
- |
- |
3 |
IS 15111 : Part 2 (2002) |
Self ballasted lamps for general lighting services: Part 2 performance requirements |
- |
-
|
65000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
6(DIMENSIONS) |
- |
2000 |
|
- |
8.1(STARTING AND RUN-UP) |
- |
3000 |
|
- |
8.2(STARTING AND RUN-UP) |
- |
0 |
|
- |
9(Lamp Wattage) |
- |
5000 |
|
- |
10(Luminous Flux) |
- |
5000 |
|
- |
11(Colour) |
- |
5000 |
|
- |
12(LUMEN MAINTENANCE) |
- |
5000 |
|
- |
13.1(Life) |
- |
24000 |
|
- |
13.2(Life) |
- |
0 |
|
- |
14(Harmonics) |
- |
5000 |
|
- |
15(Lamp Efficacy) |
- |
5000 |
|
- |
16(Power factor) |
- |
5000 |
|
- |
18.1(Marking) |
- |
1000 |
|
- |
18.2(BIS Cirtification Marking) |
- |
0 |
|
- |
|
Complete
|
|
- |
- |
4 |
IS 15111 : PART 1 AND PART 2 (2002) |
Self ballasted lamps for general lighting services: Part 1 safety requirements |
- |
-
|
35000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
6.1(Marking) |
- |
250 |
|
- |
6.2(Marking) |
- |
250 |
|
- |
6.3(Marking) |
- |
250 |
|
- |
6.4(BIS Certification Marking) |
- |
250 |
|
- |
7(Interchangeability
) |
- |
2000 |
|
- |
8(Protection against electric shock) |
- |
2000 |
|
- |
9.1(INSULATION RESISTANCE AND ELECTRIC
STRENGTH After HUMIDIT’Y TREATMENT) |
- |
2000 |
|
- |
9.2(Insulation Resistance) |
- |
1500 |
|
- |
9.3(Electric Strength) |
- |
1500 |
|
- |
10(Mechanical strength test
) |
- |
5000 |
|
- |
11(Cap Temperature rise test
) |
- |
5000 |
|
- |
12(Resistance to heat) |
- |
5000 |
|
- |
13(Resistance to Flame and Ignition) |
- |
5000 |
|
- |
14(Fault Conditions) |
- |
5000 |
|
- |
|
Complete
|
|
- |
- |
5 |
IS 10322 : Part 5 : Sec 9 (2017) |
Luminaires: Part 5 particular requirements: Sec 9 rope lights |
- |
-
|
100000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
21.4(General Test Requireements) |
- |
0 |
|
- |
21.5(Classification of Luminaires') |
- |
0 |
|
- |
21.6(Marking) |
- |
1000 |
|
- |
21.7(Construction) |
- |
24000 |
|
- |
21.8(Creepage Distance and Clearances) |
- |
2000 |
|
- |
21.9(Provision for earthing) |
- |
0 |
|
- |
21.10(Terminals) |
- |
1000 |
|
- |
21.11(External & Internal Wiring) |
- |
4000 |
|
- |
21.12(Protection against electric shock) |
- |
3000 |
|
- |
21.13(Endurance Tests and Thermal Tests) |
- |
25000 |
|
- |
21.14(Resistance to Dust & Moisture) |
- |
20000 |
|
- |
21.15(Insulation Resistance and Electric Strength) |
- |
10000 |
|
- |
21.16(Resistance to Heat , fire and tracking) |
- |
10000 |
|
- |
|
Complete
|
|
- |
- |
6 |
IS 10322 : Part 5 : Sec 8 (2013) |
Luminaires: Part 5 particular requirements: Sec 8 emergency lighting |
- |
-
|
100000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
5(Classification of Luminaires') |
- |
0 |
|
- |
6.0(Marking) |
- |
1000 |
|
- |
7.0(Construction) |
- |
12000 |
|
- |
8.0(Creepage Distance and Clearances) |
- |
2000 |
|
- |
9.0(Provision for earthing) |
- |
2000 |
|
- |
10.0(Terminals) |
- |
1000 |
|
- |
11.0(External & Internal Wiring) |
- |
4000 |
|
- |
12.0(Protection against electric shock) |
- |
2000 |
|
- |
13.0(Endurance Tests and Thermal Tests) |
- |
10000 |
|
- |
14.0(Resistance to Dust & Moisture) |
- |
10000 |
|
- |
15.0(Insulation Resistance and Electric Strength) |
- |
4000 |
|
- |
16.0(Resistance to Heat , fire and tracking) |
- |
3000 |
|
- |
17.0(Functional Safety) |
- |
25000 |
|
- |
18.0(Changeover Operation) |
- |
10000 |
|
- |
19.0(High Temperature Operation) |
- |
5000 |
|
- |
20.0(BATTERY CHARGERS FOR SELFCONTAINED EMERGENCY LUMINAIRES) |
- |
5000 |
|
- |
21.0(TEST DEVICES FOR EMERGENCY OPERATION) |
- |
2000 |
|
- |
22.0(REST MODE AND INIHIBITION MODE FACILITIES) |
- |
2000 |
|
- |
4(General Test Requireements) |
- |
0 |
|
- |
|
Complete
|
|
- |
- |
7 |
IS 10322 : Part 5 : Sec 7 (2017) |
Luminaires: Part 5 particular requirements: Sec 7 lighting chains (First Revision) |
- |
-
|
80000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
20.4(General Test Requireements) |
- |
0 |
|
- |
20.5(Classification of Luminaires') |
- |
0 |
|
- |
20.6(Marking) |
- |
1000 |
|
- |
20.7(Construction) |
- |
12000 |
|
- |
20.8(Creepage Distance and Clearances) |
- |
2000 |
|
- |
20.9(Provision for earthing) |
- |
0 |
|
- |
20.10(Terminals) |
- |
1000 |
|
- |
20.11(External & Internal Wiring) |
- |
4000 |
|
- |
20.12(Protection against electric shock) |
- |
10000 |
|
- |
20.13(Endurance Tests and Thermal Tests) |
- |
15000 |
|
- |
20.14(Resistance to Dust & Moisture) |
- |
15000 |
|
- |
20.15(Insulation Resistance and Electric Strength) |
- |
10000 |
|
- |
20.16(Resistance to Heat , fire and tracking) |
- |
10000 |
|
- |
|
Complete
|
|
- |
- |
8 |
IS 10322 : Part 5 : Sec 5 (2013) |
Luminaires: Part 5 particular requirements: Sec 5 floodlights (First Revision) |
- |
-
|
70000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
17.0(Photometric Test) |
- |
25000 |
|
- |
5(Classification of Luminaires') |
- |
0 |
|
- |
16.0(Resistance to Heat , fire and tracking) |
- |
3000 |
|
- |
15.0(Insulation Resistance and Electric Strength) |
- |
4000 |
|
- |
14.0(Resistance to Dust & Moisture) |
- |
10000 |
|
- |
6.0(Marking) |
- |
1000 |
|
- |
7.0(Construction) |
- |
7000 |
|
- |
8.0(Creepage Distance and Clearances) |
- |
2000 |
|
- |
9.0(Provision for earthing) |
- |
2000 |
|
- |
10.0(Terminals) |
- |
1000 |
|
- |
11.0(External & Internal Wiring) |
- |
3000 |
|
- |
12.0(Protection against electric shock) |
- |
2000 |
|
- |
13.0(Endurance Tests and Thermal Tests) |
- |
10000 |
|
- |
4(General Test Requireements) |
- |
0 |
|
- |
|
Complete
|
|
- |
- |
9 |
IS 10322 : PART 5 : SEC 3 (2012) |
Luminaires: Part 5 particular requirements: Sec 3 luminaires for road and street lighting (First Revision) |
- |
-
|
70000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
5(Classification of Luminaires') |
- |
0 |
|
- |
6.0(Marking) |
- |
1000 |
|
- |
7.0(Construction) |
- |
7000 |
|
- |
8.0(Creepage Distance and Clearances) |
- |
2000 |
|
- |
9.0(Provision for earthing) |
- |
2000 |
|
- |
10.0(Terminals) |
- |
1000 |
|
- |
11.0(External & Internal Wiring) |
- |
3000 |
|
- |
12.0(Protection against electric shock) |
- |
2000 |
|
- |
13.0(Endurance Tests and Thermal Tests) |
- |
10000 |
|
- |
14.0(Resistance to Dust & Moisture) |
- |
10000 |
|
- |
15.0(Insulation Resistance and Electric Strength) |
- |
4000 |
|
- |
16.0(Resistance to Heat , fire and tracking) |
- |
3000 |
|
- |
17.0(Photometric Test) |
- |
25000 |
|
- |
4(General Test Requireements) |
- |
0 |
|
- |
|
Complete
|
|
- |
- |
10 |
IS 10322 : Part 5 : Sec 2 (2012) |
Luminaires: Part 5 particular requirements: Sec 2 recessed luminaires (First Revision) |
- |
-
|
70000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
5(Classification of Luminaires') |
- |
0 |
|
- |
6(Marking) |
- |
1000 |
|
- |
7(Construction) |
- |
7000 |
|
- |
8(Creepage Distance and Clearances) |
- |
2000 |
|
- |
9(Provision for earthing) |
- |
2000 |
|
- |
10(Terminals) |
- |
1000 |
|
- |
11(External & Internal Wiring) |
- |
3000 |
|
- |
12(Protection against electric shock) |
- |
2000 |
|
- |
13(Endurance Tests and Thermal Tests) |
- |
10000 |
|
- |
14(Resistance to Dust and Moisture) |
- |
10000 |
|
- |
15(Insulation Resistance and Electric Strength) |
- |
4000 |
|
- |
16(Resistance to Heat , fire and tracking) |
- |
3000 |
|
- |
17(Photometric Test) |
- |
25000 |
|
- |
4(General Test Requireements) |
- |
0 |
|
- |
|
Complete
|
|
- |
- |
11 |
IS 16107 : Part 2 : Sec 1 (2012) |
Luminaires performance: Part 2 particular requirements: Sec 1 led luminaire |
- |
-
|
102000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
7(Total Input Power) |
- |
5000 |
|
- |
8(Light Output) |
- |
35000 |
|
- |
9(Chromaticity
Coordinates,
Correlated
colour temperature
and colour rendering) |
- |
15000 |
|
- |
10(LED Luminaire
Life) |
- |
47000 |
|
- |
|
Complete
|
|
- |
- |
12 |
IS 16107 : Part 1 (2012) |
Luminaires performance: Part 1 general requirements |
- |
-
|
75000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
2(Photometric and Electrical Data) |
- |
75000 |
|
For Photometric Data (Light Output Ration (LOR) of a Luminaire)- Rs. 20,000/-.
For Electrical Data (Input Power ;Parasitic Power ;Standby Losses ;Rated Emergency Lighting Charging Power ) - Rs. 45,000/-.
For Luminaire Efficacy Data - Rs.10,000/-. |
|
Complete
|
|
- |
- |
13 |
IS 16103 : Part 2 (2012) |
Led modules for general lighting: Part 2 performance requirements |
- |
-
|
90000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
6(Dimensions) |
- |
3000 |
|
- |
7(Module Power) |
- |
5000 |
|
- |
8(Light Output) |
- |
28000 |
|
- |
9(Chromaticity
Coordinates,
Correlated colour
temperature and
colour rendering) |
- |
9000 |
|
- |
10(LED Module Life) |
- |
30000 |
|
- |
13(Test for Emission
(Radiated and Conducted)
of radio frequency
distribution) |
- |
15000 |
|
- |
12(Information for
Luminaire design) |
- |
0 |
|
- |
|
Complete
|
|
- |
- |
14 |
IS 16103 : Part 1 (2012) |
Led modules for general lighting: Part 1 safety requirements |
- |
-
|
37500 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
7(Marking) |
- |
500 |
|
- |
8(Terminals) |
- |
1000 |
|
- |
9(PROVISION FOR EARTHING) |
- |
2000 |
|
- |
10(Protection against accidental contact with live parts) |
- |
2000 |
|
- |
11(Mositure Resistance and Insulation) |
- |
8000 |
|
- |
12(Electric Strength) |
- |
2500 |
|
- |
13(Fault conditions) |
- |
8000 |
|
- |
15(Construction) |
- |
4500 |
|
- |
16(Creepage distance and clearances) |
- |
3000 |
|
- |
17(Screws, current carrying parts and connections) |
- |
1500 |
|
- |
18(Resistance to heat, fire and tracking) |
- |
3000 |
|
- |
19(Resistance to corrosion) |
- |
1500 |
|
- |
|
Complete
|
|
- |
- |
15 |
IS 16102 : Part 2 (2017) |
Self - Ballasted led lamps for general lighting services: Part 2 performance requirements (First Revision) |
- |
-
|
175000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
6(Dimensions) |
- |
3000 |
|
Including Rs. 1000 for Marking (Cl. 5) |
8(Lamp Input) |
- |
32000 |
|
Rs. 4000 ( for Lamp power) ; Rs. 4000 (for Power Factor); Rs. 4000 (for Harmonics); Rs. 20000 (for Emission of Radio frequency) |
9(light output) |
- |
40000 |
|
Rs. 10000 (for Luminous Flux);Rs. 15000 (for Luminous Intensity Distribution) ; Rs. 15000 (for Peak Intensity Value & beam Angel Value and Efficacy) |
10(Colour Nomenclature,
Variation and
Rendering) |
- |
15000 |
|
- |
11(Lamp Life) |
- |
85000 |
|
Rs. 40000 (for Lamp life & Lumen maintenance) ; Rs. 45000 (for Endurance Tests) |
|
Complete
|
|
- |
- |
16 |
IS 16102 : Part 1 (2012) |
Self - Ballasted led lamps for general lighting services: Part 1 safety requirements |
- |
-
|
50000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
5(Marking) |
- |
1000 |
|
- |
6(Interchangeability) |
- |
10000 |
|
For Cl. 6.1 (Cap Interchangeability)- Rs. 2000/- and For Cl. 6.2 (Bending Moment. Axial Pull and Mass)- Rs. 8,000/. |
7(Protection against accidental contact with live parts) |
- |
4000 |
|
- |
8(Insulation Resistance and Electric Strength) |
- |
10000 |
|
- |
9(MECHANICAL STRENGTH) |
- |
1000 |
|
- |
10(cap temperature) |
- |
5000 |
|
- |
11(Resistance to Heat) |
- |
4000 |
|
- |
12(Resistance to Flame and Ignition) |
- |
5000 |
|
- |
13(Fault conditions) |
- |
8000 |
|
- |
14(Creepage distance and clearances) |
- |
2000 |
|
- |
|
Complete
|
|
- |
- |
17 |
IS 16046 : Part 2 (2018) |
Secondary Cells and Batteries Containing Alkaline or Other Non-Acid Electrolytes ” Safety Requirements for Portable Sealed Secondary Cells and for Batteries Made from Them for Use in Portable Applications Part 2 Lithium Systems ( Second Revision ) |
- |
-
|
65000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
5.2(Insulation and Wiring) |
- |
2000 |
|
for Lithium Cell Testing - 0.
Note:- Refer BIS website for Total testing charges.
Battery (Rs.65,000/-) and Cell (Rs.80,000/-) ;
*Coin cell (Rs.90,000/-) |
7.1(Charging procedure for test purposes) |
- |
5000 |
|
Rs. 10000 for Lithium Cell. |
7.2(Intended Use) |
- |
10000 |
|
Same for Lithium Cell & Battery Testing. |
7.3(Reasonably foreseeable misuse) |
- |
40000 |
|
Rs. 50000 for Lithium Cell. |
9.3(Caution for ingestion of small cells and batteries) |
- |
500 |
|
Same for Lithium Cell & Battery Testing. |
4(Parameter Measurement Tolerances) |
- |
0 |
|
- |
5(General Safety Considerations) |
- |
2000 |
|
Same for Lithium Cell & Battery Testing. |
5.1(General) |
- |
0 |
|
- |
5.3(Venting) |
- |
0 |
|
- |
5.4(Temperature, Voltage and Current Management) |
- |
0 |
|
- |
5.5(Terminal Contacts) |
- |
0 |
|
- |
5.6(Assembly of Cells into batteries) |
- |
0 |
|
- |
5.7(Quality Plan) |
- |
0 |
|
- |
5.8(Battery Safety Components) |
- |
0 |
|
- |
6(Type Test and Sample Size) |
- |
0 |
|
- |
7(Specific requirements and tests) |
- |
0 |
|
Refer testing charges of Cl. 7.1; Cl. 7.2 & Cl. 7.3 |
8(Information for safety) |
- |
3500 |
|
for Lithium Cell testing- Rs.5500. |
8.1(General) |
- |
0 |
|
- |
8.2(Small Cell and battery safety information) |
- |
0 |
|
- |
9(Marking) |
- |
0 |
|
- |
9.1(Cell Marking) |
- |
1000 |
|
- |
9.2(Battery Marking) |
- |
1000 |
|
- |
9.4(Other information) |
- |
0 |
|
Note:- Annex D (Meaurement of the Internal AC resistance for Coin cells) Rs. 10,000. |
10(Packaging) |
- |
1000 |
|
Same for Lithium Cell & Battery Testing. |
|
Complete
|
|
- |
- |
18 |
IS 15885 : Part 2 : Sec 13 (2012) |
Safety of lamp controlgear: Part 2 particular requirements: Sec 13 d.c. or a.c. supplied electronic controlgear for led modules |
- |
-
|
45000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
7(Marking) |
- |
1000 |
|
- |
8(Protection against accidental contact with live parts) |
- |
2000 |
|
- |
9(Terminals) |
- |
1000 |
|
- |
10(PROVISION FOR EARTHING) |
- |
4000 |
|
- |
11(MOISTURE RESISTANCE) |
- |
5000 |
|
- |
12(Electric Strength) |
- |
2000 |
|
- |
14(Fault conditions) |
- |
5000 |
|
- |
15(Transformer heating) |
- |
10000 |
|
- |
16(Construction) |
- |
2000 |
|
- |
17(Creepage distance and clearances) |
- |
3000 |
|
- |
18(Screws, current carrying parts and connections) |
- |
3000 |
|
- |
19(Resistance to heat, fire and tracking) |
- |
5000 |
|
- |
20(Resistance to corrosion) |
- |
2000 |
|
- |
|
Complete
|
|
- |
- |
19 |
IS 302 : Part 2 : Sec 15 (2009) |
Safety of household and similar electrical appliances: Part 2 particular requirements: Sec 15 appliances for heating liquids (First Revision) |
- |
-
|
50000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
6.0(Classification) |
- |
0 |
|
- |
7(Marking and instructions) |
- |
1000 |
|
- |
8(Protection against live parts) |
- |
2000 |
|
- |
10(POWER INPUT AND CURRENT) |
- |
2000 |
|
- |
11(HEATING) |
- |
4000 |
|
- |
13(LEAKAGE CURRENT AND ELECTRIC STRENGTH AT OPERATING TEMPERATURE) |
- |
3000 |
|
- |
14(TRANSIENT OVERVOLTAGES) |
- |
2000 |
|
- |
15(MOISTURE RESISTANCE) |
- |
3000 |
|
- |
16(LEAKAGE CURRENT AND ELECTRIC STRENGTH) |
- |
3000 |
|
- |
17(OVERLOAD PROTECTION OF TRANSFORMERS AND ASSOCIATED CIRCUITS) |
- |
2000 |
|
- |
19(ABNORMAL OPERATION) |
- |
5000 |
|
- |
20(STABILITY AND MECHANICAL HAZARDS) |
- |
1000 |
|
- |
21(MECHANICAL STRENGTH) |
- |
3000 |
|
- |
22(CONSTRUCTION) |
- |
4000 |
|
- |
23(INTERNAL WIRING) |
- |
1000 |
|
- |
25(SUPPLY CONNECTION AND EXTERNAL FLEXIBLE CORDS) |
- |
1000 |
|
- |
26(TERMINALS FOR EXTERNAL CONDUCTORS) |
- |
1000 |
|
- |
27(PROVISION FOR EARTHING) |
- |
2000 |
|
- |
28(SCREWS AND CONNECTIONS) |
- |
1000 |
|
- |
29(CLEARANCES, CREEPAGE DISTANCES AND SOLID INSULATION) |
- |
2000 |
|
- |
30(RESISTANCE TO HEAT AND FIRE) |
- |
5000 |
|
- |
31(RESISTANCE TO RUSTING) |
- |
1000 |
|
- |
32(RADIATION, TOXICITY AND SIMILAR HAZARDS) |
- |
1000 |
|
- |
|
Complete
|
|
- |
- |
20 |
IS 302 : Part 2 : Sec 6 (2009) |
Safety of household and similar electrical appliances: Part 2 particular requirements: Sec 6 cooking ranges, hobs, ovens and similar appliances (First Revision) |
- |
-
|
23100 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
6.0(Classification) |
- |
0 |
|
- |
7.0(Marking and instructions) |
- |
500 |
|
- |
8.0(Protection against access to live part test) |
- |
1000 |
|
- |
10.0(Power Input and current test) |
- |
1000 |
|
- |
11.0(Heating test) |
- |
1500 |
|
- |
13.0(Leakage current and electric strength test) |
- |
1500 |
|
- |
14.0(Transient voltages) |
- |
1000 |
|
- |
15.0(Moisture Resistance) |
- |
1000 |
|
- |
16.0(Leakage current and electric strength test) |
- |
1000 |
|
- |
17.0(Overload protection of transformers test) |
- |
1000 |
|
- |
19.0(Abnormal Operations) |
- |
3000 |
|
- |
20.0(Stability and Mechanical Hazards) |
- |
500 |
|
- |
21.0(Mechanical Strength) |
- |
1500 |
|
- |
22.0(Construction verification related tests) |
- |
2600 |
|
- |
23.0(Internal wiring) |
- |
500 |
|
- |
25.0(Supply connections and External Flexible Cords) |
- |
500 |
|
- |
26.0(Terminal for External Conductors) |
- |
500 |
|
- |
27.0(Provision for Earthing) |
- |
1000 |
|
- |
28.0(Screws and connections) |
- |
500 |
|
- |
29.0(Clearances and Creepage distances and solid insulation) |
- |
1000 |
|
- |
30.0(Resistance to heat and fire) |
- |
1500 |
|
- |
31.0(Resistance to rusting) |
- |
500 |
|
- |
32.0(Radiation, Toxicity and Similar hazards) |
- |
0 |
|
- |
|
Complete
|
|
- |
- |
21 |
IS 302 : Part 1 (2008) |
Safety of household and similar electrical appliances: Part 1 general requirements (Sixth Revision) |
- |
-
|
50000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
7(Marking and instructions) |
- |
1000 |
|
- |
8.1.1(Protection against live parts in all positions) |
- |
500 |
|
- |
8.1.2(Protection against live parts in openings) |
- |
500 |
|
- |
8.1.3(Protection against live parts in visible glowing heating elements) |
- |
500 |
|
- |
8.1.4(Protection against live parts against protective impedance) |
- |
500 |
|
- |
10.1(Power input) |
- |
1000 |
|
- |
10.2(Current input) |
- |
1000 |
|
- |
11.1(General) |
- |
0 |
|
- |
11.2(General) |
- |
0 |
|
- |
11.3(Heating) |
- |
4000 |
|
- |
13.1(General) |
- |
0 |
|
- |
13.2(Leakage current at operating temperature) |
- |
1500 |
|
- |
13.3(Electric Strength at operating temperature) |
- |
1500 |
|
- |
14(Transient Over Voltages) |
- |
2000 |
|
- |
15.1(Ingress Protection test other than IPX0 (IP test)) |
- |
1000 |
|
- |
15.2(Spillage Test) |
- |
1000 |
|
- |
15.3(Humidity Test) |
- |
1000 |
|
- |
16.1(General) |
- |
0 |
|
- |
16.2(Leakage Current (after Clause 15)) |
- |
1500 |
|
- |
16.3(Electric Strength (after clause 15 and 16.2)) |
- |
1500 |
|
- |
17(Over Load Protection of Transformers and associated circuits) |
- |
2000 |
|
- |
19(Abnormal Operation) |
- |
5000 |
|
- |
20(Stability test) |
- |
1000 |
|
- |
21(Mechanical Strength Test) |
- |
3000 |
|
- |
22(Construction verification related test) |
- |
4000 |
|
- |
23(General) |
- |
1000 |
|
(For Internal Wiring) |
25(Supply connection and external flexible cords) |
- |
1000 |
|
- |
26(Terminals for external conductors) |
- |
1000 |
|
- |
27(Provision for earthing) |
- |
2000 |
|
- |
28(Screw test and connections) |
- |
1000 |
|
- |
29(clearance, creepage distances and solid insulation) |
- |
2000 |
|
- |
30.1(Ball pressure test) |
- |
2000 |
|
- |
30.2(Glow Wire Test) |
- |
1500 |
|
- |
30.2(Needle Flame Test) |
- |
1500 |
|
- |
31(Resistance to Rusting) |
- |
1000 |
|
- |
15.0(General) |
- |
0 |
|
- |
16.0(General) |
- |
0 |
|
- |
18(Endurance Test requirements and tests) |
- |
0 |
|
- |
32(Radiation Toxicity and Similar Hazards) |
- |
1000 |
|
- |
|
Complete
|
|
- |
- |
22 |
IS 16046 : Part 1 (2018) |
Secondary Cells and Batteries Containing Alkaline or Other Non-Acid Electrolytes ” Safety Requirements for Portable Sealed Secondary Cells and for Batteries Made from Them for Use in Portable Applications Part 1 Nickel Systems ( Second Revision ) |
- |
-
|
75000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
5(General Safety Considerations) |
- |
2000 |
|
Refer BIS website
Battery (Rs. 75,000/-) and Cell (rs. 1,00,000/-) |
7.1(Charging procedure for test purposes) |
- |
5000 |
|
Same testing charges for battery & Cell. |
7.2(Intended Use) |
- |
32000 |
|
Rs. 35000 for Nickel Cell. |
7.3(Reasonably foreseeable misuse) |
- |
30000 |
|
Rs. 55000 for Nickel Cell. |
8.2(Small Cell and battery safety information) |
- |
1000 |
|
Same testing charges for battery & Cell. |
5.1(General) |
- |
0 |
|
- |
5.3(Venting) |
- |
0 |
|
- |
5.4(Temperature, Voltage and Current Management) |
- |
0 |
|
- |
5.5(Terminal Contacts) |
- |
0 |
|
- |
5.6(Assembly of Cells into batteries) |
- |
0 |
|
- |
4(Parameter Measurement Tolerances) |
- |
0 |
|
- |
5.2(Insulation and Wiring) |
- |
2000 |
|
- |
5.7(Quality Plan) |
- |
0 |
|
- |
6(Tyoe Test amd Sample Size) |
- |
0 |
|
- |
7(Specific requirements and tests) |
- |
0 |
|
Refer testing charges for Cl. 7.1, Cl. 7.2 & Cl. 7.3. |
8(Information for safety) |
- |
1000 |
|
Rs. 2000 for Nickel Cell. |
8.1(General) |
- |
0 |
|
- |
9(Marking) |
- |
0 |
|
- |
9.1(Cell Marking) |
- |
1000 |
|
- |
9.2(Battery Marking) |
- |
1000 |
|
- |
9.4(Other information) |
- |
0 |
|
- |
10(Packaging) |
- |
0 |
|
- |
9.3(Caution for ingestion of small cells and batteries) |
- |
1000 |
|
Same testing charges for battery & Cell. |
|
Complete
|
|
- |
- |
23 |
IS 13252 : Part 1 (2010) |
Information technology equipment - Safety: Part 1 general requirements (Second Revision) |
- |
-
|
50000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
1.6(Power interface .) |
- |
2000 |
|
Refer to the BIS website for grants of recognition for various types of products. |
1.7(Markings and instructions) |
- |
1000 |
|
Refer to the BIS website for grants of recognition for various types of products. |
2.1(Protection from electric shock and energy hazards) |
- |
2000 |
|
Refer to the BIS website for grants of recognition for various types of products. |
2.2(SELV circuits) |
- |
2000 |
|
Refer to the BIS website for grants of recognition for various types of products. |
2.3(TNV circuits) |
- |
3000 |
|
Refer to the BIS website for grants of recognition for various types of products. |
2.4(Limited current circuits) |
- |
2000 |
|
Refer to the BIS website for grants of recognition for various types of products. |
1.5(Components) |
- |
1000 |
|
Refer to the BIS website for grants of recognition for various types of products. |
2.5(Limited power sources .) |
- |
2000 |
|
Refer to the BIS website for grants of recognition for various types of products. |
2.6(Provisions for earthing and bonding) |
- |
2000 |
|
Refer to the BIS website for grants of recognition for various types of products. |
2.7(Overcurrent and earth fault protection in primary circuits) |
- |
2000 |
|
Refer to the BIS website for grants of recognition for various types of products. |
2.8(Safety interlocks) |
- |
0 |
|
Refer to the BIS website for grants of recognition for various types of products. |
2.9(Electrical insulation) |
- |
10000 |
|
Charges vary fromRs. 5000 to Rs. 15000 as per the type of product. (Refer to BIS website).
Refer to the BIS website for grants of recognition for various types of products. |
2.10(Clearances, creepage distances and distances through insulation) |
- |
4000 |
|
Refer to the BIS website for grants of recognition for various types of products. |
3.1(General) |
- |
1000 |
|
Refer to the BIS website for grants of recognition for various types of products. |
3.2(Connection to a mains supply) |
- |
1000 |
|
Refer to the BIS website for grants of recognition for various types of products. |
3.3(Wiring terminals for connection of external conductors) |
- |
1000 |
|
Refer to the BIS website for grants of recognition for various types of products. |
3.4(Disconnection from the mains supply) |
- |
1000 |
|
Refer to the BIS website for grants of recognition for various types of products. |
3.5(Interconnection of equipment) |
- |
2000 |
|
Refer to the BIS website for grants of recognition for various types of products. |
4.1(Stability) |
- |
2000 |
|
Refer to the BIS website for grants of recognition for various types of products. |
4.2(Mechanical strength) |
- |
3000 |
|
Refer to the BIS website for grants of recognition for various types of products. |
4.3(Design and construction) |
- |
4000 |
|
Refer to the BIS website for grants of recognition for various types of products. |
4.4(Protection against hazardous moving parts) |
- |
2000 |
|
Refer to the BIS website for grants of recognition for various types of products. |
4.5(Thermal requirements) |
- |
3000 |
|
Refer to the BIS website for grants of recognition for various types of products. |
4.6(Openings in enclosures) |
- |
2000 |
|
Refer to the BIS website for grants of recognition for various types of products. |
4.7(Resistance to fire) |
- |
3000 |
|
Refer to the BIS website for grants of recognition for various types of products. |
5.1(Touch current and protective conductor curren) |
- |
2000 |
|
Refer to the BIS website for grants of recognition for various types of products. |
5.2(Electric strength) |
- |
2000 |
|
Refer to the BIS website for grants of recognition for various types of products. |
5.3(Abnormal operating and fault conditions) |
- |
4000 |
|
Refer to the BIS website for grants of recognition for various types of products. |
6.1(Protection of telecommunication network service persons, and users of other equipment connected to the network, from hazards in the equipment) |
- |
1000 |
|
Refer to the BIS website for grants of recognition for various types of products. |
6.2(Protection of equipment users from overvoltages on networks telecommunication) |
- |
1000 |
|
Refer to the BIS website for grants of recognition for various types of products. |
6.3(Protection of the telecommunication wiring system from overheating) |
- |
1000 |
|
Refer to the BIS website for grants of recognition for various types of products. |
7.1(General) |
- |
1000 |
|
Refer to the BIS website for grants of recognition for various types of products. |
7.2(Protection of cable distribution system service persons, and users of other equipment connected to the system, from hazardous voltages in the equipment) |
- |
2000 |
|
Refer to the BIS website for grants of recognition for various types of products. |
7.3(Protection of equipment users from overvoltages on the cable distribution system) |
- |
2000 |
|
Refer to the BIS website for grants of recognition for various types of products. |
7.4(Insulation between primary circuits and cable distribution systems) |
- |
1000 |
|
Refer to the BIS website for grants of recognition for various types of products. |
|
Complete
|
|
- |
- |
24 |
IS 10322 : Part 5 : Sec 1 (2012) |
Luminaires: Part 5 particular requirements: Sec 1 fixed general purpose luminaires (First Revision) |
- |
-
|
70000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
5(Classification of Luminaires') |
- |
0 |
|
- |
6.0(Marking) |
- |
1000 |
|
- |
7.0(Construction) |
- |
7000 |
|
- |
8.0(Creepage Distance and Clearances) |
- |
2000 |
|
- |
9.0(Provision for earthing) |
- |
2000 |
|
- |
10.0(Terminals) |
- |
1000 |
|
- |
11.0(External & Internal Wiring) |
- |
3000 |
|
- |
12.0(Protection against electric shock) |
- |
2000 |
|
- |
13.0(Endurance Tests and Thermal Tests) |
- |
10000 |
|
- |
14.0(Resistance to Dust & Moisture) |
- |
10000 |
|
- |
15.0(Insulation Resistance and Electric Strength) |
- |
4000 |
|
- |
16.0(Resistance to Heat , fire and tracking) |
- |
3000 |
|
- |
17.0(Photometric Test) |
- |
25000 |
|
- |
4(General Test Requireements) |
- |
0 |
|
- |
|
Complete
|
|
- |
- |
25 |
IS 10322 : Part 5 : Sec 6 (2013) |
Luminaires: Part 5 particular requirements: Sec 6 handlamps |
- |
-
|
60000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
5(Classification of Luminaires') |
- |
0 |
|
- |
7.0(Construction) |
- |
7000 |
|
- |
6.0(Marking) |
- |
1000 |
|
- |
8.0(Creepage Distance and Clearances) |
- |
2000 |
|
- |
10.0(Terminals) |
- |
1000 |
|
- |
11.0(External & Internal Wiring) |
- |
12000 |
|
- |
12.0(Protection against electric shock) |
- |
2000 |
|
- |
13.0(Endurance Tests and Thermal Tests) |
- |
15000 |
|
- |
14.0(Resistance to Dust & Moisture) |
- |
10000 |
|
- |
15.0(Insulation Resistance and Electric Strength) |
- |
5000 |
|
- |
16.0(Resistance to Heat , fire and tracking) |
- |
5000 |
|
- |
4(General Test Requireements) |
- |
0 |
|
- |
|
Complete
|
|
- |
- |
26 |
IS 616 (2017) |
Audio, video and similar electronic apparatus - Safety requirements (Fifth Revision) |
- |
-
|
50000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
5(Marking and instructions) |
- |
1000 |
|
15 products are granted by BIS . (Refer BIS website). |
7(Heating under normal operating conditions) |
- |
5000 |
|
15 products are granted by BIS . (Refer BIS website). |
8(Constructional requirements with regard to the protection against electric shock) |
- |
5000 |
|
15 products are granted by BIS . (Refer BIS website). |
9(Electric shock hazard under normal operating conditions) |
- |
7000 |
|
15 products are granted by BIS . (Refer BIS website). |
10(Insulation requirements) |
- |
10000 |
|
Testing charges vary from Rs. 5000 to Rs. 20000 for a variety of products approved by BIS.
15 products are granted by BIS . (Refer BIS website). |
11(Fault conditions) |
- |
5000 |
|
15 products are granted by BIS . (Refer BIS website). |
12(Mechanical strength) |
- |
8000 |
|
15 products are granted by BIS . (Refer BIS website). |
13(CLEARANCES and CREEPAGE DISTANCES) |
- |
5000 |
|
15 products are granted by BIS . (Refer BIS website). |
14(Components) |
- |
5000 |
|
15 products are granted by BIS . (Refer BIS website). |
15(TERMINALS) |
- |
3000 |
|
15 products are granted by BIS . (Refer BIS website). |
16(External flexible cords) |
- |
5000 |
|
15 products are granted by BIS . (Refer BIS website). |
17(Electrical connections and mechanical fixings) |
- |
3000 |
|
15 products are granted by BIS . (Refer BIS website). |
19(Stability and mechanical hazards) |
- |
10000 |
|
15 products are granted by BIS . (Refer BIS website). |
20(Resistance to fire) |
- |
3000 |
|
15 products are granted by BIS . (Refer BIS website). |
6(Hazardous radiations) |
- |
0 |
|
15 products are granted by BIS . (Refer BIS website). |
|
Complete
|
|
- |
- |