| 1 |
IS 12933 : Part 1 (2003) |
Solar flat plate collector - Specification: Part 1 requirements (Second Revision) |
Designed for Normal Fluid Temp. less than 100 Degree C |
100000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 7.1.1(Static Pressure Leakage Test) |
- |
3000 |
|
GST Extra |
| 7.2.1(Outdoor No Flow Exposure Test ) |
- |
3000 |
|
GST Extra |
| 7.2.2(External Thermal Shock Test ) |
- |
3000 |
|
GST Extra |
| 7.2.2(Internal Thermal Shock Test ) |
- |
3000 |
|
GST Extra |
| 7.2.4(Rain Penetration Test) |
- |
3000 |
|
GST Extra |
| 7.2.5(Impact Resistance Test) |
- |
3000 |
|
GST Extra |
| 7.2.6(Thermal Efficiency Test) |
- |
45000 |
|
GST Extra |
| 7.2.7(Determination of the Time Constant ) |
- |
3000 |
|
GST Extra |
| 7.2.8(Incident Angle Modifier Test) |
- |
22000 |
|
GST Extra |
| 4(Components: The various components of solar flat plate collector shall be as specified in IS 12933 (Part 2)) |
- |
6000 |
|
GST Extra |
| 5(SHAPE AND DIMENSIONS) |
- |
6000 |
|
GST Extra |
|
26 Oct, 2026 |
- - |
| 2 |
IS 12933 (Part 2) (2025) |
Solar Flat Plate Collector - Specification Part 2 Components (Third Revision) |
Designed for Normal Fluid Temp. less than 100 Degree C |
9000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl-4(Material (cover plate)) |
- |
1000 |
|
- |
| Cl-5.1(Transmittance Test) |
- |
1000 |
|
- |
| Cl-5.1.2(cover glass of the solar collector) |
- |
0 |
|
- |
| Cl-5.1.3(Global solar radiation) |
- |
0 |
|
- |
| Cl-6(Material (Collector Box)) |
- |
0 |
|
- |
| Cl-6.1 (a)(Aluminum alloy) |
- |
0 |
|
- |
| Cl-6.1 (b)(Fibre glass) |
- |
0 |
|
- |
| Cl-6.2(Minimum thickness) |
- |
0 |
|
- |
| Cl-7(Workmanship and Finish) |
- |
1000 |
|
- |
| Cl-7.3(Resistance to Abrasion) |
- |
0 |
|
- |
| Cl-8(Fabrication) |
- |
1000 |
|
- |
| Cl-9(Absorber) |
- |
0 |
|
- |
| Cl-9.1.4(Temperature Test) |
- |
1000 |
|
- |
| Cl-9.2.1(Static Pressure Leakage Test) |
- |
1000 |
|
- |
| Cl-9.2.2(Bonding between Riser and Sheet) |
- |
1000 |
|
- |
| Cl-10(Back and Side Insulation) |
- |
1000 |
|
- |
| Cl-11(Material (Gaskets and Grommets)) |
- |
1000 |
|
- |
| Cl-12.1.1(Thermal Shock Test) |
- |
1000 |
|
- |
| Cl-6.1 (c)(CRCA steel) |
- |
0 |
|
- |
| Cl-6.1 (d)(Galvanized steel sheets) |
- |
0 |
|
- |
| Cl-6.1 (e)(continuously pre-painted galvanized steel) |
- |
0 |
|
- |
| Cl-6.1 (f)(HRC steel sheets) |
- |
0 |
|
- |
| Cl-6.1 (d)(continuously pre-painted galvanized steel) |
- |
0 |
|
- |
| Cl-6.1 (e)(HRC steel sheets) |
- |
0 |
|
- |
|
26 Oct, 2026 |
- Included w.e.f. 22.01.2026 |
| 3 |
IS 12933 : Part 1 (2025) |
Solar Flat Plate Collector - Specification Part 1 Requirements (Third Revision) |
Designed for Normal Fluid Temp. less than 100 Degree C |
100000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl-4(Components) |
- |
6000 |
|
- |
| Cl-5(Shape and Dimensions) |
- |
6000 |
|
- |
| Cl-6(Assembly and Workmanship) |
- |
0 |
|
- |
| Cl-7.1.1(Static Pressure Leakage Test) |
- |
3000 |
|
- |
| Cl-7.2.1(Outdoor No Flow Exposure Test) |
- |
3000 |
|
- |
| Cl-7.2.2(External Thermal Shock Test) |
- |
3000 |
|
- |
| Cl-7.2.3(Internal Thermal Shock Test) |
- |
3000 |
|
- |
| Cl-7.2.4(Rain Penetration Test) |
- |
3000 |
|
- |
| Cl-7.2.5(Impact Resistance Test) |
- |
3000 |
|
- |
| Cl-7.2.6(Thermal Efficiency Test) |
- |
45000 |
|
- |
| Cl-7.2.7(Determination of the Time Constant) |
- |
3000 |
|
- |
| Cl-7.2.8(Incident Angle Modifier Test) |
- |
22000 |
|
- |
| Cl-9(Marking) |
- |
0 |
|
- |
| Cl-4(Components) |
- |
6000 |
|
- |
| Cl-5(Shape and Dimensions) |
- |
6000 |
|
- |
| Cl-6(Assembly and Workmanship) |
- |
0 |
|
- |
| Cl-7.1.1(Static Pressure Leakage Test) |
- |
3000 |
|
- |
| Cl-7.2.1(Outdoor No Flow Exposure Test) |
- |
3000 |
|
- |
| Cl-7.2.2(External Thermal Shock Test) |
- |
3000 |
|
- |
| Cl-7.2.3(Internal Thermal Shock Test) |
- |
3000 |
|
- |
| Cl-7.2.4(Rain Penetration Test) |
- |
3000 |
|
- |
| Cl-7.2.5(Impact Resistance Test) |
- |
3000 |
|
- |
| Cl-7.2.6(Thermal Efficiency Test) |
- |
45000 |
|
- |
| Cl-7.2.7(Determination of the Time Constant) |
- |
3000 |
|
- |
| Cl-7.2.8(Incident Angle Modifier Test) |
- |
22000 |
|
- |
| Cl-9(Marking) |
- |
0 |
|
- |
|
26 Oct, 2026 |
- Included w.e.f. 22.01.2026 |
| 4 |
IS 16543 (2024) |
All-glass evacuated solar collector tubes - Specification (First revision) |
Non-Concentrating Type Solar Collector Hot water O/P |
14000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl 7.2.2(Uniformity) |
- |
250 |
|
GST Extra |
| Cl 7.4(Stagnation Performance Parameter Test) |
- |
1200 |
|
GST Extra |
| Cl 7.5(Stagnation Solar Irradiation Test) |
- |
1200 |
|
GST Extra |
| Cl 7.6(Average Heat Loss Coefficient Test) |
- |
1200 |
|
GST Extra |
| Cl 7.7(Vacuum Performance Test) |
- |
1200 |
|
GST Extra |
| Cl 7.8(Resistance to Thermal Shock Test) |
- |
1500 |
|
GST Extra |
| Cl 7.9(Resistance to Impact Test) |
- |
250 |
|
GST Extra |
| Cl 7.10(0 Resistance to Internal Pressure Test) |
- |
250 |
|
GST Extra |
| Cl 7.11(Absorptivity and Emissivity Test of the Selective Coating) |
- |
1200 |
|
GST Extra |
| Cl 5.1.1(Transmittance ratio ( material)) |
- |
250 |
|
GST Extra |
| Cl 5.1.2(Bubble & crack (material)) |
- |
250 |
|
GST Extra |
| Cl 5.1.3(Knots (material)) |
- |
250 |
|
GST Extra |
| Cl 5.1.4(Solar absorbing ratio (material)) |
- |
250 |
|
GST Extra |
| Cl 5.2.1(Scratch length and visibility) |
- |
250 |
|
GST Extra |
| Cl 5.2.3(Colour fading area) |
- |
250 |
|
GST Extra |
| Cl 5.2.6(Length of an all-glass evacuated solar collector tube) |
- |
250 |
|
GST Extra |
| Cl 5.2.7(Bending of the all-glass evacuated solar collector tube) |
- |
250 |
|
GST Extra |
| Cl 5.2.8(Cross-section of the open end) |
- |
250 |
|
GST Extra |
| Cl 4.2 & table 1(Outer Diameter of Cover Glass Tube) |
- |
250 |
|
GST Extra |
| Cl 4.2 & table 1(Outer Diameter of Inner Glass Tube Including Coating) |
- |
250 |
|
GST Extra |
| Cl 4.2 & table 1(Tube Length) |
- |
250 |
|
GST Extra |
| Cl 4.2 & table 1(The Thickness of Cover and Inner Glass Tube) |
- |
250 |
|
GST Extra |
| Cl 4.2 & table 1(Sealed off Part Length) |
- |
250 |
|
GST Extra |
| Cl 4.3(Absorber Area for Different Tube Sizes) |
- |
250 |
|
GST Extra |
| Cl 4.5(Calculation for Number of Tubes for The Heating System) |
- |
250 |
|
GST Extra |
| Cl 4.1(Structure of All-Glass Evacuated Solar Collector Tube) |
- |
250 |
|
GST Extra |
| Cl 5.2.2(Appearance of selective coating) |
- |
250 |
|
GST Extra |
| Cl 5.2.5(The inner and cover tube at the open end) |
- |
250 |
|
GST Extra |
| Cl 5.2.9(Sealed end) |
- |
250 |
|
GST Extra |
| Cl 9(Marking) |
- |
250 |
|
GST Extra |
| Cl 4.4(Solar Selective Absorbing Coating) |
- |
250 |
|
GST Extra |
| Cl 5.2.4(Strut member) |
- |
250 |
|
GST Extra |
|
26 Oct, 2026 |
- - |
| 5 |
IS 16544 (2016) |
All glass evacuated tubes solar water heating system |
Non-Concentrating Direct Vented Solar Collector |
100000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6.1(Pre-Conditioning Test) |
- |
6000 |
|
GST Extra |
| 6.2.1 (Annex - B)(Exterior Test) |
- |
6000 |
|
GST Extra |
| 6.2.2 (Annex - C)(Leakage Test) |
- |
6000 |
|
GST Extra |
| 6.2.3 (Annex - D)(Stagnation Test) |
- |
6000 |
|
GST Extra |
| 6.2.4 (Annex - E)(External Thermal Shock Test) |
- |
6000 |
|
GST Extra |
| 6.2.5 (Annex - F)(Internal Thermal Shock Test) |
- |
6000 |
|
GST Extra |
| 6.2.6(Thermal Performance Test) |
- |
60000 |
|
GST Extra |
| 6.2.7() |
- |
2000 |
|
GST Extra |
| 5(General Requirements) |
- |
2000 |
|
GST Extra |
|
26 Oct, 2026 |
- - |
| 6 |
IS 16368 (2015) |
Test procedure for thermosyphon type domestic solar hot water heating systems |
Non-Concentrating Direct Vented Solar Collector |
80000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6.1(Pre-Conditioning Test) |
- |
14000 |
|
GST Extra |
| 6.2(Static Pressure Leakage Test) |
- |
6000 |
|
GST Extra |
| 7(Thermal Performance Test) |
- |
60000 |
|
GST Extra |
|
26 Oct, 2026 |
- - |
| 7 |
IS 16542 (2016) |
Direct insertion type storage water tank for all glass evacuated tubes solar collector - Specification |
Direct Insertion Type |
10000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 8.3(Ideal Heating Test) |
- |
1000 |
|
GST Extra |
| 8.2(Leakage Test) |
- |
1000 |
|
GST Extra |
| 8.4(Integral Test) |
- |
1000 |
|
GST Extra |
| 8.5(Performance Test) |
- |
3000 |
|
GST Extra |
| 7.6(Thermal Shock Test for Inner Sealing) |
- |
1000 |
|
GST Extra |
| 7.7(Thermal Shock Test for outer Sealing) |
- |
1000 |
|
GST Extra |
| 6(GENERAL REQUIREMENTS) |
- |
1000 |
|
GST Extra |
| 8.1(Measurement of Storage Water Tank Capacity) |
- |
1000 |
|
GST Extra |
|
26 Oct, 2026 |
- - |
| 8 |
IS 12933 : Part 2 (2003) |
Solar flat plate collector - Specification: Part 2 components (Second Revision) |
Designed for Normal Fluid Temp. less than 100 Degree C |
9000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 5.1(Transmittance Test) |
- |
1000 |
|
GST Extra |
| 9.1.4(Temperature Test) |
- |
1000 |
|
GST Extra |
| 12.1.1(Thermal Shock Test) |
- |
1000 |
|
GST Extra |
| 7(WORKMANSHIP AND FINISH) |
- |
1000 |
|
GST Extra |
| 8(FABRICATION) |
- |
1000 |
|
GST Extra |
| 9.2.1(Static Pressure Leakage Test) |
- |
1000 |
|
GST Extra |
| 9.2.2(Bonding Between Riser and Sheet) |
- |
1000 |
|
GST Extra |
| 10(BACK AND SIDE INSULATION) |
- |
1000 |
|
GST Extra |
| 11(MATERIALS) |
- |
1000 |
|
GST Extra |
|
26 Oct, 2026 |
- - |
| 9 |
IS 16543 (2016) |
All glass evacuated solar collector tubes - Specification |
Non-Concentrating Type Solar Collector Hot water O/P |
7500 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 7.3 (Annex - A)(Stagnation Performance Parameter Test) |
- |
750 |
|
GST Extra |
| 7.4 (Annex - B)(Stagnation Solar Irradiance Test) |
- |
750 |
|
GST Extra |
| 7.5 (Annex - C)(Average Heat Loss Coefficient Test) |
- |
750 |
|
GST Extra |
| 7.6 (Annex - D-1)(Air Pressure Test Inside the Vacuum Jacket) |
- |
500 |
|
GST Extra |
| 7.6 (Annex - D-2)(Vacuum Quality Test) |
- |
500 |
|
GST Extra |
| 7.7 (Annex - E)(Resistance to Thermal Shock Test) |
- |
750 |
|
GST Extra |
| 7.8 (Annex - F)(Resistance to Impact Test) |
- |
500 |
|
GST Extra |
| 7.9 (Annex - G)(Resistance to Internal Pressure Test) |
- |
750 |
|
GST Extra |
| 7.10 (Annex - H-2)(Absorptivity Test of Selective Coating) |
- |
750 |
|
GST Extra |
| 7.10 (Annex - H-3)(Emissivity Test of selective coating) |
- |
750 |
|
GST Extra |
| 5(GENERAL REQUIREMENTS) |
- |
250 |
|
GST Extra |
| 7.1(Dimensions) |
- |
250 |
|
GST Extra |
| 7.2(Appearance and Dimensions) |
- |
250 |
|
GST Extra |
|