1 |
IS 16543 (2016) |
All glass evacuated solar collector tubes - Specification |
Non-Concentrating Type Solar Collector Hot water O/P |
-
|
7500 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
7.3 (Annex - A)(Stagnation Performance Parameter Test) |
- |
750 |
|
GST Extra |
7.4 (Annex - B)(Stagnation Solar Irradiance Test) |
- |
750 |
|
GST Extra |
7.5 (Annex - C)(Average Heat Loss Coefficient Test) |
- |
750 |
|
GST Extra |
7.6 (Annex - D-1)(Air Pressure Test Inside the Vacuum Jacket) |
- |
500 |
|
GST Extra |
7.6 (Annex - D-2)(Vacuum Quality Test) |
- |
500 |
|
GST Extra |
7.7 (Annex - E)(Resistance to Thermal Shock Test) |
- |
750 |
|
GST Extra |
7.8 (Annex - F)(Resistance to Impact Test) |
- |
500 |
|
GST Extra |
7.9 (Annex - G)(Resistance to Internal Pressure Test) |
- |
750 |
|
GST Extra |
7.10 (Annex - H-2)(Absorptivity Test of Selective Coating) |
- |
750 |
|
GST Extra |
7.10 (Annex - H-3)(Emissivity Test of selective coating) |
- |
750 |
|
GST Extra |
5(GENERAL REQUIREMENTS) |
- |
250 |
|
GST Extra |
7.1(Dimensions) |
- |
250 |
|
GST Extra |
7.2(Appearance and Dimensions) |
- |
250 |
|
GST Extra |
|
Complete
|
|
26 Oct, 2026 |
- |
2 |
IS 16544 (2016) |
All glass evacuated tubes solar water heating system |
Non-Concentrating Direct Vented Solar Collector |
-
|
50000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
6.1(Pre-Conditioning Test) |
- |
3000 |
|
GST Extra |
6.2.1 (Annex - B)(Exterior Test) |
- |
3000 |
|
GST Extra |
6.2.2 (Annex - C)(Leakage Test) |
- |
3000 |
|
GST Extra |
6.2.3 (Annex - D)(Stagnation Test) |
- |
3000 |
|
GST Extra |
6.2.4 (Annex - E)(External Thermal Shock Test) |
- |
3000 |
|
GST Extra |
6.2.5 (Annex - F)(Internal Thermal Shock Test) |
- |
3000 |
|
GST Extra |
6.2.6(Thermal Performance Test) |
- |
30000 |
|
GST Extra |
6.2.7() |
- |
1000 |
|
GST Extra |
5(General Requirements) |
- |
1000 |
|
GST Extra |
|
Complete
|
|
26 Oct, 2026 |
- |
3 |
IS 16368 (2015) |
Test procedure for thermosyphon type domestic solar hot water heating systems |
Non-Concentrating Direct Vented Solar Collector |
-
|
40000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
6.1(Pre-Conditioning Test) |
- |
7000 |
|
GST Extra |
6.2(Static Pressure Leakage Test) |
- |
3000 |
|
GST Extra |
7(Thermal Performance Test) |
- |
30000 |
|
GST Extra |
|
Complete
|
|
26 Oct, 2026 |
- |
4 |
IS 16542 (2016) |
Direct insertion type storage water tank for all glass evacuated tubes solar collector - Specification |
Direct Insertion Type |
-
|
5000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
8.3(Ideal Heating Test) |
- |
250 |
|
GST Extra |
8.2(Leakage Test) |
- |
500 |
|
GST Extra |
8.4(Integral Test) |
- |
500 |
|
GST Extra |
8.5(Performance Test) |
- |
1500 |
|
GST Extra |
7.6(Thermal Shock Test for Inner Sealing) |
- |
500 |
|
GST Extra |
7.7(Thermal Shock Test for outer Sealing) |
- |
500 |
|
GST Extra |
6(GENERAL REQUIREMENTS) |
- |
250 |
|
GST Extra |
8.1(Measurement of Storage Water Tank Capacity) |
- |
500 |
|
GST Extra |
|
Complete
|
|
26 Oct, 2026 |
- |
5 |
IS 12933 : Part 1 (2003) |
Solar flat plate collector - Specification: Part 1 requirements (Second Revision) |
Designed for Normal Fluid Temp. less than 100 Degree C |
-
|
45500 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
7.1.1(Static Pressure Leakage Test) |
- |
1500 |
|
GST Extra |
7.2.1(Outdoor No Flow Exposure Test ) |
- |
1500 |
|
GST Extra |
7.2.2(External Thermal Shock Test ) |
- |
1500 |
|
GST Extra |
7.2.2(Internal Thermal Shock Test ) |
- |
1500 |
|
GST Extra |
7.2.4(Rain Penetration Test) |
- |
1500 |
|
GST Extra |
7.2.5(Impact Resistance Test) |
- |
1500 |
|
GST Extra |
7.2.6(Thermal Efficiency Test) |
- |
20000 |
|
GST Extra |
7.2.7(Determination of the Time Constant ) |
- |
1500 |
|
GST Extra |
7.2.8(Incident Angle Modifier Test) |
- |
10000 |
|
GST Extra |
4(Components: The various components of solar flat plate collector shall be as specified in IS 12933 (Part 2)) |
- |
2500 |
|
GST Extra |
5(SHAPE AND DIMENSIONS) |
- |
2500 |
|
GST Extra |
|
Complete
|
|
26 Oct, 2026 |
- |
6 |
IS 12933 : Part 2 (2003) |
Solar flat plate collector - Specification: Part 2 components (Second Revision) |
Designed for Normal Fluid Temp. less than 100 Degree C |
-
|
4500 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
5.1(Transmittance Test) |
- |
500 |
|
GST Extra |
9.1.4(Temperature Test) |
- |
500 |
|
GST Extra |
12.1.1(Thermal Shock Test) |
- |
500 |
|
GST Extra |
7(WORKMANSHIP AND FINISH) |
- |
500 |
|
GST Extra |
8(FABRICATION) |
- |
500 |
|
GST Extra |
9.2.1(Static Pressure Leakage Test) |
- |
500 |
|
GST Extra |
9.2.2(Bonding Between Riser and Sheet) |
- |
500 |
|
GST Extra |
10(BACK AND SIDE INSULATION) |
- |
500 |
|
GST Extra |
11(MATERIALS) |
- |
500 |
|
GST Extra |
|
Complete
|
|
26 Oct, 2026 |
- |