8.7(Direction of Rotation) |
- |
500 |
|
nil |
9.10 (b)(High Voltage test) |
- |
500 |
|
NIL |
9.10 (a)(Insulation Resistance test) |
- |
500 |
|
NIL |
9.10 (h)(Leakage current test) |
- |
500 |
|
NIL |
9.10 (f) & (g)(Locked Rotor Test) |
- |
500 |
|
NIL |
9.10 (d)(No Load Test at Rated Voltage) |
- |
500 |
|
NIL |
10.3(Hydrostatic Pressure Test) |
- |
500 |
|
NIL |
10(Pump Performance test) |
- |
1500 |
|
NIL |
14(Marking) |
- |
500 |
|
NIL |
8.5(Balancing of rotor) |
- |
500 |
|
NIL |
9.10 (j)(Temperature Rise Test at Rated Voltage) |
- |
500 |
|
NIL |
9.10 (k)(Temperature rise test at reduced voltage) |
- |
500 |
|
NIL |
9.10 (c)(Measurement of Stator Resistance) |
- |
500 |
|
nil |
10.2(Laboratory Tests
Cl.8 of IS 11346-2002
Rate of flow and head
Cl.8 of IS 11346-2002) |
- |
500 |
|
nil |
11.1.1(Guarantee of Performance) |
- |
500 |
|
nil |
11.1.2(Guarantee of Performance) |
- |
500 |
|
nil |
11.1.3(Guarantee of Performance) |
- |
500 |
|
nil |
11.1.4(Guarantee of Performance) |
- |
500 |
|
nil |
11.1.5(Guarantee of Performance) |
- |
500 |
|
nil |
8.5.1(Balancing) |
- |
500 |
|
NIL |
8.1(General Requirements) |
- |
500 |
|
NIL |