1 |
IS 14543 (2024) |
Packaged Drinking Water Other than Packaged Natural Mineral Water Specification Third Revision |
- |
-
|
- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Cl-5.3, Table-1 (i) (Colour, true colour units, Max) |
- |
|
|
|
Cl-5.3, Table-1 (ii) (Odour) |
- |
|
|
|
Cl-5.3, Table-1 (iii) (Taste) |
- |
|
|
|
Cl-5.3, Table-1 (iv) (Turbidity, nephelometric turbidity unit (NTU), Max) |
- |
|
|
|
Cl-5.3, Table-1 (v) (Total dissolved solids, mg/l, Max) |
- |
|
|
|
Cl-5.3, Table-1 (vi) (pH) |
- |
|
|
|
Cl-5.3, Table-2 (i) (Barium (as Ba)) |
- |
|
|
|
Cl-5.3, Table-2 (ii) (Copper (as Cu)) |
- |
|
|
|
Cl-5.3, Table-2 (iii) (Iron (as Fe)) |
- |
|
|
|
Cl-5.3, Table-2 (iv) (Manganese (as Mn)) |
- |
|
|
|
Cl-5.3, Table-2 (v) (Nitrate (as NO3 )) |
- |
|
|
|
Cl-5.3, Table-2 (vi) (Nitrite (as NO2 )) |
- |
|
|
|
Cl-5.3, Table-2 (vii) (Fluoride (as F)) |
- |
|
|
|
Cl-5.3, Table-2 (viii) (Zinc (as Zn)) |
- |
|
|
|
Cl-5.3, Table-2 (ix) (Silver (as Ag)) |
- |
|
|
|
Cl-5.3, Table-2 (x) (Aluminium (as A1)) |
- |
|
|
|
Cl-5.3, Table-2 (xi) (Chloride (as Cl)) |
- |
|
|
|
Cl-5.3, Table-2 (xii) (Selenium (as Se)) |
- |
|
|
|
Cl-5.3, Table-2 (xiii) (Sulphate (as SO4 )) |
- |
|
|
|
Cl-5.3, Table-2 (xiv) (Alkalinity (as HCO3 )) |
- |
|
|
|
Cl-5.3, Table-2 (xv) (Calcium (as Ca)) |
- |
|
|
|
Cl-5.3, Table-2 (xvi) (Magnesium (as Mg)) |
- |
|
|
|
Cl-5.3, Table-2 (xvii) (Sodium (as Na)) |
- |
|
|
|
Cl-5.3, Table-2 (xviii) (Residual free chlorine) |
- |
|
|
|
Cl-5.3, Table-2 (xx) (Mineral oil) |
- |
|
|
|
Cl-5.3, Table-2 (xxii) (Sulphide) |
- |
|
|
|
Cl-5.3, Table-2 (xxiii) (Antimony (as Sb)) |
- |
|
|
|
Cl-5.3, Table-2 (xxiv) (Borates (as B)) |
- |
|
|
|
Cl-5.3, Table-2 (xxv) (Bromates (as BrO3 )) |
- |
|
|
|
Cl-5.3, Table-3 (i) (Mercury (as Hg)) |
- |
|
|
|
Cl-5.3, Table-3 (ii) (Cadmium (as Cd)) |
- |
|
|
|
Cl-5.3, Table-3 (iii) (Arsenic (as As)) |
- |
|
|
|
Cl-5.3, Table-3 (v) (Lead (as Pb)) |
- |
|
|
|
Cl-5.3, Table-3 (vi) (Chromium (as Cr)) |
- |
|
|
|
Cl-5.3, Table-3 (vii) (Nickel (as Ni)) |
- |
|
|
|
Cl-5.3, Table-3 (viii) (Polychlorinated biphenyl (PCB)) |
- |
|
|
|
Cl-5.3, Table-3 (ix) (Polynuclear aromatic hydrocarbons) |
- |
|
|
|
Cl-5.3, Table-3 (x) (Uranium) |
- |
|
|
|
Cl-5.2.1 (Escherichia coli or thermotolerant bacteria) |
- |
|
|
|
Cl-5.2.2 (Coliform) |
- |
|
|
|
Cl-5.2.3 (Faecal streptococci) |
- |
|
|
|
Cl-5.2.3 (Staphylococcus aureus) |
- |
|
|
|
Cl-5.2.4 (Sulphite Reducing Anaerobes) |
- |
|
|
|
Cl-5.2.5 (Pseudomonas Aeruginosa) |
- |
|
|
|
Cl-5.2.6 (Aerobic Microbial Count @ 37 deg C) |
- |
|
|
|
5.2.6 (Aerobic Microbial Count @ 20 to 22 deg C) |
- |
|
|
|
Cl-5.2.7 (Yeast and mould) |
- |
|
|
|
Cl-5.2.8 (Salmonella) |
- |
|
|
|
Cl-5.2.8 (shigella) |
- |
|
|
|
Cl-5.2.9 (Vibrio cholera) |
- |
|
|
|
Cl-5.2.9 (V.parahaemolyticus) |
- |
|
|
|
|
Partial
|
|
- |
Test facility not available for Cyanide, Anionic surface active agents, Phenolic compounds, Radio active residues |
2 |
IS 12818 (2010) |
Unplasticized polyvinyl chloride (Pvc - U) screen and casing pipes for bore/tubewells - Specification (Second Revision) |
- |
-
|
- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
No Record Found
|
|
Partial
|
|
- |
- |
3 |
IS 14756 (2017) |
Stainless steel cookware - Specification (First Revision) |
- |
-
|
- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
No Record Found
|
|
Partial
|
|
- |
- |
4 |
IS 17569 (2021) |
Insulated Containers for Food Storage — Specification |
- |
-
|
- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
No Record Found
|
|
Partial
|
|
- |
- |
5 |
IS 17526 (2021) |
STAINLESS STEEL VACUUM FLASKS - SPECIFICATION |
- |
-
|
- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
5 (Manufacture and Workmanship) |
- |
|
|
|
5.3 (Manufacture and Workmanship) |
- |
|
|
|
7.3 (Capacity) |
- |
|
|
|
7.4 (Heat Retention Capability) |
- |
|
|
|
7.5 (Cold Retention Capability) |
- |
|
|
|
7.6.1 (Drop Impact Test) |
- |
|
|
|
7.6.2 (Pendulum Impact Test) |
- |
|
|
|
7.7 (Fixing Strength of the Handle) |
- |
|
|
|
7.8 (Test for Strength of Shoulder Strap) |
- |
|
|
|
7.8.1 (Test for strength of cord) |
- |
|
|
|
7.9 (Leakage Test) |
- |
|
|
|
7.10 (Joint Leak Test) |
- |
|
|
|
7.11 (Staining Test) |
- |
|
|
|
7.12 (Length of the Shoulder Strap) |
- |
|
|
|
7.13 (Stability of Flask/Bottle) |
- |
|
|
|
7.14 (Pour Test) |
- |
|
|
|
7.2 (Arrangement for holding and suspension) |
- |
|
|
|
|
Partial
|
|
- |
- |
6 |
IS 14756 (2022) |
Draft Indian Standard STAINLESS STEEL COOKWARE SPECIFICATION Second Revision of IS 14756 |
- |
-
|
- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
No Record Found
|
|
Partial
|
|
- |
- |
7 |
IS 17790 (2022) |
INSULATED FLASK FOR DOMESTIC USE SPECIFICATION |
- |
-
|
- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
No Record Found
|
|
Partial
|
|
- |
- |
8 |
IS 12786 (2024) |
Irrigation equipment - Polyethylene pipes for irrigation laterals - Specification (first revision) |
- |
-
|
- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
4.2(a) (Carbon Black Content-IS 2530) |
- |
|
|
|
4.2(b) (Carbon Black Dispersion-IS 2530) |
- |
|
|
|
3 (Class of Pipe) |
- |
|
|
|
5.1 & Table 1 (Dimensions of Pipes - Outside diameters) |
- |
|
|
|
5.1 & Table 1 (Dimensions of Pipes - Wall thickness) |
- |
|
|
|
6 (Visual Appearance) |
- |
|
|
|
7.1 & Table 2 (Hydraulic Characteristics) |
- |
|
|
|
7.1 & Table 2 (Hydraulic Characteristics) |
- |
|
|
|
7.2 (Reversion Test) |
- |
|
|
|
7.3 (Tensile Strength) |
- |
|
|
|
7.3 (Elongation at Break) |
- |
|
|
|
7.4 (SusceptibiIity to Environmental Stress Cracking) |
- |
|
|
|
|
Partial
|
|
- |
- |
9 |
IS 3319 (1995) |
Blades, surgical, detachable (Bard Parker Type) and handles - Specification (Fourth Revision) |
- |
-
|
- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
8,8.1 (Sterilization) |
- |
|
|
|
|
Partial
|
|
- |
Available only for Micro |
10 |
IS 302 : Part 2 : Sec 15 (2009) |
Safety of household and similar electrical appliances: Part 2 particular requirements: Sec 15 appliances for heating liquids (First Revision) |
pressure cookers having a rated cooking pressure not exceeding 140 kPa and a rated capacity not exceeding 10 l |
-
|
- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
6 (Classification- IS 302-1) |
- |
|
|
|
6 (Classification- IS 302-1) |
- |
|
|
|
7.1 (Marking- IS 302-1) |
- |
|
|
|
7.1 (Marking- IS 302-1) |
- |
|
|
|
7.1 (Marking- IS 302-1) |
- |
|
|
|
7.1 (Marking- IS 302-1) |
- |
|
|
|
7.1 (Marking- IS 302-1) |
- |
|
|
|
7.1 (Marking- IS 302-1) |
- |
|
|
|
7.1 (Marking- IS 302-1) |
- |
|
|
|
7.1 (Marking- IS 302-1) |
- |
|
|
|
7.1 (Marking- IS 302-2-15) |
- |
|
|
|
7.3 (Marking- IS 302-1) |
- |
|
|
|
7.4 (Marking- IS 302-1) |
- |
|
|
|
7.5 (Marking- IS 302-1) |
- |
|
|
|
7.6 (Marking- IS 302-1) |
- |
|
|
|
7.7 (Marking- IS 302-1) |
- |
|
|
|
7.8 (Marking- IS 302-1) |
- |
|
|
|
7.1O (Marking- IS 302-1) |
- |
|
|
|
7.11 (Marking- IS 302-1) |
- |
|
|
|
7.12 (Marking- IS 302-2-15) |
- |
|
|
|
7.12 (Marking- IS 302-1) |
- |
|
|
|
7.12.1 (Marking- IS 302-1) |
- |
|
|
|
7.12.3 (Marking- IS 302-1) |
- |
|
|
|
7.12.5 (Marking- IS 302-1) |
- |
|
|
|
7.12.6 (Marking- IS 302-1) |
- |
|
|
|
7.13 (Marking- IS 302-1) |
- |
|
|
|
7.14 (Marking- IS 302-1) |
- |
|
|
|
7.15 (Marking- IS 302-1) |
- |
|
|
|
7.101 (Marking- IS 302-2-15) |
- |
|
|
|
8 (Protection Against Electric Shock, IS 302-1) |
- |
|
|
|
10 (Power Input and Current, IS 302-1) |
- |
|
|
|
11 (Heating, IS 302-1) |
- |
|
|
|
11 (Heating, IS 302-1) |
- |
|
|
|
11 (Heating, IS 302-1) |
- |
|
|
|
11 (Heating, IS 302-1) |
- |
|
|
|
13 (Electrical Insulation and Leakage Current at Operating Temperature: Leakage current, IS 302-1) |
- |
|
|
|
13 (Electrical Insulation and Leakage Current at Operating Temperature: High Voltage, IS 302-1) |
- |
|
|
|
15.1 (Moisture Resistance, IS 302-1) |
- |
|
|
|
15.2 (Spillage test as 15.2, IS 3.02-1 & 302-2-15) |
- |
|
|
|
16 (Leakage current as per Cl 16, IS 302-1) |
- |
|
|
|
|
Partial
|
|
- |
- |
11 |
IS 261 (2023) |
COPPER SULPHATE SPECIFICATION |
- |
-
|
- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
4.1 (Description ( IS 261 : 2023)) |
- |
|
|
|
4.2Table 1 (i) (Copper ( IS 261 : 2023)) |
- |
|
|
|
4.2 Table 1 (ii) (Matter insoluble in water ( IS 261 : 2023)) |
- |
|
|
|
4.2 Table 1 (iii) (Soluble iron and aluminium compounds (as Fe) ( IS 261 : 2023)) |
- |
|
|
|
4.2 Table 1 (iv) (pH value ( IS 261 : 2023)) |
- |
|
|
|
4.2 Table 1 (v) (Chloride (as Cl) ( IS 261 : 2023)) |
- |
|
|
|
4.2 Table 1 (vi) (Arsenic (as As₂O₃) ( IS 261 : 2023)) |
- |
|
|
|
4.2 Table 1 (vii) (Lead and zinc ( IS 261 : 2023)) |
- |
|
|
|
|
Partial
|
|
- |
Complete test facility available for Technical grade |
12 |
IS 1165 (2022) |
WHOLE MILK POWDER - SPECIFICATION (Sixth Revision of IS 1165) |
- |
-
|
- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
3.1 (Discription) |
- |
|
|
|
3.2 (Flavour and Taste) |
- |
|
|
|
3.3 (extraneous matter) |
- |
|
|
|
Clause 3.5,Table 1 ,Sl No i) (Moisture) |
- |
|
|
|
Clause 3.5,Table 1 ,Sl No ii) (Total solids) |
- |
|
|
|
Clause 3.5,Table 1 ,Sl No iii) (Milk fat) |
- |
|
|
|
Clause 3.5,Table 1 ,Sl No iv) (Milk protein in milk solids not fat) |
- |
|
|
|
Clause 3.5,Table 1 ,Sl No v) (Insolubility index) |
- |
|
|
|
Clause 3.5,Table 1 ,Sl No vi) (Total ash(on dry basis)) |
- |
|
|
|
Clause 3.5,Table 1 ,Sl No vii) (Titratable acidity (lactic acid),) |
- |
|
|
|
Clause 3.5,Table 1 ,Sl No viii) (Scorched particle) |
- |
|
|
|
Clause 3.7,Table 3, Sl No i) (Lead) |
- |
|
|
|
Clause 3.5,Table 2 ,Sl No i) (Aerobic plate count) |
- |
|
|
|
Clause 3.5,Table 2 ,Sl No ii) (Coliform Count) |
- |
|
|
|
Clause 3.5,Table 2 ,Sl No iii) (Staphylococcus aureus(Coagulase positive)) |
- |
|
|
|
Clause 3.5,Table 2 ,Sl No iv) (Yeast and mould count) |
- |
|
|
|
Clause 3.5,Table 2 ,Sl No v) (Salmonella sp) |
- |
|
|
|
Clause 3.5,Table 2 ,Sl No vi) (Listeria monocytogenes) |
- |
|
|
|
Clause 3.5,Table 2 ,Sl No vii) (Bacillus cereus) |
- |
|
|
|
Clause 3.5,Table 2 ,Sl No viii) (Sulphite reducing clostridia) |
- |
|
|
|
Clause 3.5,Table 2 ,Sl No ix) (E. coli) |
- |
|
|
|
|
Partial
|
|
- |
Test facility not available for Melamine |
13 |
IS 2347 (2023) |
DOMESTIC PRESSURE COOKER � SPECIFICATION |
- |
-
|
- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
4 (Capacity) |
- |
|
|
|
4.2 (Body Capacity) |
- |
|
|
|
6 (Construction) |
- |
|
|
|
6.1 (Pressure Regulating Device) |
- |
|
|
|
6.1.1 (Pressure Regulating Device) |
- |
|
|
|
6.1.1 (Minimum Inside diameter of Vent Pipe.) |
- |
|
|
|
6.1.2 (Pressure Regulating Device) |
- |
|
|
|
6.1.3 (Pressure Regulating Device) |
- |
|
|
|
6.1.4 (Pressure Regulating Device) |
- |
|
|
|
6.1.5 (Pressure Regulating Device) |
- |
|
|
|
6.1.6 (Pressure Regulating Device) |
- |
|
|
|
6.2 (Safety Relief Device) |
- |
|
|
|
6.2.1 (Safety Relief Device) |
- |
|
|
|
6.2.2 (Safety Relief Device) |
- |
|
|
|
6.2.3 (Safety Relief Device) |
- |
|
|
|
6.3.1 (Temperature Responsive Safety Relief Device) |
- |
|
|
|
6.3.2 (Temperature Responsive Safety Relief Device) |
- |
|
|
|
6.4.1.1 (Handles and Knobs) |
- |
|
|
|
6.4.2 (Handles and Knobs) |
- |
|
|
|
6.7 (Internal Level Marking) |
- |
|
|
|
6.8 (Internal Level Marking) |
- |
|
|
|
7.1 (WORKMANSHIP AND FINISH) |
- |
|
|
|
7.2 (WORKMANSHIP AND FINISH) |
- |
|
|
|
7.3 (WORKMANSHIP AND FINISH) |
- |
|
|
|
7.4 (WORKMANSHIP AND FINISH) |
- |
|
|
|
8.1 (Air Pressure Test) |
- |
|
|
|
8.2 (Proof Pressure Test) |
- |
|
|
|
8.3.1 (Operating Test for Pressure Regulating Device) |
- |
|
|
|
8.4.1 (Test for Safety Relief Device) |
- |
|
|
|
8.4.2 (Test for Safety Relief Device) |
- |
|
|
|
8.4.2 NOTE (Test for Safety Relief Device) |
- |
|
|
|
8.5 (Bursting Pressure Test) |
- |
|
|
|
8.6.1 (Tests for Removal of Lid under Pressure For Outer Lid Cooker) |
- |
|
|
|
8.6.2 (Tests for Removal of Lid under Pressure For inner Lid Cooker) |
- |
|
|
|
8.6.3 (Tests for Removal of Lid under Pressure: For Cooker Fastened by Screw Clamps or Any Other Locking Device) |
- |
|
|
|
8.7 (Test for Spring Loaded Mechanism) |
- |
|
|
|
8.8 (Test for stainless steel cookers) |
- |
|
|
|
8.9 ("For stainless steel, aluminium induction
compatible base and 3 ply cooker") |
- |
|
|
|
8.10 (Testing of Handles of the cooker) |
- |
|
|
|
8.10 Note 3 (Testing of Handles of the cooker) |
- |
|
|
|
8.10 Note 4 (Testing of Handles of the cooker) |
- |
|
|
|
8.10 Note 5 (Testing of Handles of the cooker) |
- |
|
|
|
8.10 Note 6 (Testing of Handles of the cooker) |
- |
|
|
|
8.11.1 (External Coating) |
- |
|
|
|
8.12 (Internal Coating) |
- |
|
|
|
8.14 (Ply construction cooker Body ) |
- |
|
|
|
8.15.1 (Fragmentation Test on Tempered Glass lid) |
- |
|
|
|
8.15.2 (Ball Drop Test on Tempered Glass lid) |
- |
|
|
|
8.15.3 (Thermal Shock Test on Tempered Glass lid) |
- |
|
|
|
8.15.4.1 ("Free Fall Test ( Glass lid with rim)
") |
- |
|
|
|
8.15.4.2 (Glass lid without rim) |
- |
|
|
|
8.16 (PRD with chain) |
- |
|
|
|
8.17 (Test for Effectiveness for Induction Bottom) |
- |
|
|
|
8.3.1 (Operating Test for Pressure Regulating Device) |
- |
|
|
|
8.4.1 (Test for Safety Relief Device) |
- |
|
|
|
|
Partial
|
|
- |
Except Material Testing |
14 |
IS 333 (2023) |
POTASSIUM PERMANGANATE SPECIFICATION |
- |
-
|
- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Cl-4.1 (Description) |
- |
|
|
|
Cl-4.2,Table-1,sl.no-i (Potassium permanganate (as KMnO4) content,) |
- |
|
|
|
Cl-4.2,Table-1,sl.no-ii (Insoluble matter) |
- |
|
|
|
Cl-4.2,Table-1,sl.no-iii ( Chlorides (as Cl)) |
- |
|
|
|
Cl-4.2,Table-1,sl.no-iv (Sulphate (as SO4)) |
- |
|
|
|
Cl-4.2,Table-1,sl.no-v (Nitrogen compounds (as N)) |
- |
|
|
|
Cl-4.2,Table-1,sl.no-vi (Arsenic (as As2O3),) |
- |
|
|
|
Cl-4.2,Table-1,sl.no-vii (Loss on heating at 110 °C) |
- |
|
|
|
|
Partial
|
|
- |
- |
15 |
IS 14781 (2000) |
Sodium thiosulphate - Specification |
- |
-
|
- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
4.1 (Description) |
- |
|
|
|
4.3, Table No - 1 , 1), i) (Sodium thiosulphate (as Na2S203.5H20). percent by mass) |
- |
|
|
|
4.3, Table No - 1 , 1), ii) (pH of 10 percent solution) |
- |
|
|
|
4.3, Table No - 1 , 1), iii) (Insoluble matter and metals other than alkali metals, percent by mass, Max) |
- |
|
|
|
4.3, Table No - 1 , 1), iv) (Sodium sulphide (as Na.$G), percent by mass, Max) |
- |
|
|
|
4.3, Table No - 1 , 1), v) (Heavy metals (as Pb), percent by mass, Max) |
- |
|
|
|
4.3, Table No - 1 , 1), vi) (Iron (as Fe), percent by mass, Max) |
- |
|
|
|
4.3, Table No - 1 , 1), vii) (Calcium (as Ca). percent by mass, Max) |
- |
|
|
|
4.3, Table No - 1 , 1), viii) (Sulphate and sulphite (as SO4), percent by mass, Max) |
- |
|
|
|
4.3, Table No - 1 , 1), ix) (Arsenic (as As2O3), percent by mass, Max) |
- |
|
|
|
4.2 (Solution in Water) |
- |
|
|
|
|
Partial
|
|
- |
- |
16 |
IS 4408 (1979) |
Specification for sodium chloride, analytical reagent (First Revision) |
- |
-
|
- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
2.1 (Description) |
- |
|
|
|
2.2, Table 1,(i) (Sodium chloride, percent by mass, Min) |
- |
|
|
|
2.2, Table 1,(ii) (Sulphate ( as SO4 ), percent by mass, Max) |
- |
|
|
|
2.2, Table 1,(iii) (Nitrate ( as NO3 ), percent by mass, Max) |
- |
|
|
|
2.2, Table 1,(iv) (Phosphates ( as PO4 ), percent by mass, Max) |
- |
|
|
|
2.2, Table 1,(v) (Iron ( as Fe ), percent by mass, Max) |
- |
|
|
|
2.2, Table 1,(vi) (Heavy metals (as Pb), percent by mass, Max) |
- |
|
|
|
2.2, Table 1,(vii) (Barium (as Ba), percent by mass, Max) |
- |
|
|
|
2.2, Table 1,(viii) (Calcium and magnesium together ( as Ca ), percent by mass, Max) |
- |
|
|
|
2.2, Table 1,(ix) (Potassium (as K), percent by mass, Max) |
- |
|
|
|
2.2, Table 1,(x) (Ammonium salts ( as NH4 ), percent by mass, Max) |
- |
|
|
|
2.2, Table 1,(xi) (Arsenic (as As), percent by mass, Max) |
- |
|
|
|
2.2, Table 1,(xii) (pH of 10 percent solution) |
- |
|
|
|
2.2, Table 1,(xiii) (Bromide and iodide ( as Br ), percent by mass, Max) |
- |
|
|
|
2.2, Table 1,(xiv) (Insoluble matter, percent by mass, Max) |
- |
|
|
|
2.2, Table 1,(xv) (Ferrocyanide [ at Fe ( CN )6 ] percent by mass, Max) |
- |
|
|
|
|
Partial
|
|
- |
- |
17 |
IS 2052 (2023) |
Compounded feeds for cattle � Specification |
- |
-
|
- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Cl no.4.1 (General) |
- |
|
|
|
Cl no.4.3,7.1, Table no. 1(i) (Moisture) |
- |
|
|
|
Cl no.4.3,7.1, Table no. 1(ii) (Crude protein (N × 6.25)) |
- |
|
|
|
Cl no.4.3, 7.1,Table no. 1(iii) (Crude fat) |
- |
|
|
|
Cl no.4.3 ,7.1, Table no. 1(iv) (Crude fibre) |
- |
|
|
|
Cl no.4.3 ,7.1, Table no. 1(v) (Acid insoluble ash) |
- |
|
|
|
Cl no.4.3,7.1Table no. 1(vi) ("Salt (as NaCl based on Na or
Cl), percent by mass") |
- |
|
|
|
Cl no.4.3 7.1,Table no. 1(vii) (Calcium (as Ca)) |
- |
|
|
|
Cl no.4.3,7.1,Table no. 1(viii) (Total phosphorus) |
- |
|
|
|
Cl no.4.3 ,7.1, Table no. 1(xv) (Cadmium) |
- |
|
|
|
|
Partial
|
|
- |
Exclusion
Except Available phosphorus,Urea,Vitamin A,Vitamin D3,Vitamin E and Aflatoxin B1 |
18 |
IS 1659 (2004) |
Block boards - Specification (Fourth Revision) |
- |
-
|
- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
8.1.3, 6.3.3, IS 303 (Visual Inspection - Permissible Defects - IS 303 [test method for COMMERCIAL type]) |
- |
|
|
|
8.1.3, 6.3.3, IS 1328 (Visual Inspection - Permissible Defects - IS 1328 [test method for DECORATIVE type]) |
- |
|
|
|
7.3 (Dimensional Requirements - Length - 8.1.4) |
- |
|
|
|
7.3 (Dimensional Requirements - Width - 8.1.4) |
- |
|
|
|
7.3 (Dimensional Requirements - Thickness - Annexure E) |
- |
|
|
|
7.3 (Dimensional Requirements - Edge Straightness - Annexure D) |
- |
|
|
|
7.3 (Dimensional Requirements - Squareness - Annexure D) |
- |
|
|
|
7.3 (Dimensional Requirements - Variation in thickness - Annexure E) |
- |
|
|
|
9.2.1 (Dimensional Changes caused by humidity - Change in Length - at 90% RH - Annexure F) |
- |
|
|
|
9.2.1 (Dimensional Changes caused by humidity - Change in Length - at 40% RH - Annexure F) |
- |
|
|
|
9.2.1 (Dimensional Changes caused by humidity - Change in Thickness - at 90% RH - Annexure F) |
- |
|
|
|
9.2.1 (Dimensional Changes caused by humidity - Change in thickness - at 40% RH - Annexure F) |
- |
|
|
|
9.2.1 (Dimensional Changes caused by humidity - Delamination - Annexure F) |
- |
|
|
|
9.2.1 (Dimensional Changes caused by humidity Change in local planeness - Annexure F) |
- |
|
|
|
9.2.2 (Resistance to water - Annexure G, Annexure H [For BWP grade]) |
- |
|
|
|
9.2.2 (Resistance to water - Annexure G, Annexure H [For MR Grade]) |
- |
|
|
|
9.2.3 (Adhesion of Plies - Annexure H) |
- |
|
|
|
9.2.4 (Mycological Test [for MR grade only] - Annexure J) |
- |
|
|
|
9.2.5 (Modulus of rupture - AVERAGE - Annexure K) |
- |
|
|
|
9.2.5 (Modulus of rupture - MINIMUM INDIVIDUAL - Annexure K) |
- |
|
|
|
9.2.5 (Modulus of elasticity - AVERAGE - Annexure K) |
- |
|
|
|
9.2.5 (Modulus of elasticity - MINIMUM INDIVIDUAL - Annexure K) |
- |
|
|
|
9.2.6 (Spot test - Annexure L) |
- |
|
|
|
|
Partial
|
|
- |
- |
19 |
IS 13488 (2008) |
Irrigation equipment - Emitting pipe systems - Specification (First Revision) |
- |
-
|
- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
6.2.2 (Fittings) |
- |
|
|
|
6.3 (General) |
- |
|
|
|
6.3 (General) |
- |
|
|
|
8.1.2 (Uniformity of Emission Rate for Unregulated Emitting Pipes) |
- |
|
|
|
8.1.3 (Uniformity of Emission Rate for Regulated Emitting Pipes) |
- |
|
|
|
8.2 (Emission Rate of Emitting Unit as a Function of Inlet Pressure) |
- |
|
|
|
8.2.1 (Unregu/Qt~d Emining Pipe) |
- |
|
|
|
8.2.2 (Regulated Emitting Pipes) |
- |
|
|
|
8.3.1 (Wall Thickness ofEmitting Pipe) |
- |
|
|
|
8.3.2 (Inside Diameter ofEmitting Pipe) |
- |
|
|
|
8.3.3 (Flow Paths in Emitting Unit) |
- |
|
|
|
8.3.4 (Spacing ofEmitter Units) |
- |
|
|
|
8.4.1 (Resistance to Hydrostatic Pressure at Ambient Temperature) |
- |
|
|
|
8.4.2 (Resistance to Hydrostatic Pressure at Elevated Temperature) |
- |
|
|
|
8.5 (Resistance to Tension at Elevated Temperature) |
- |
|
|
|
8.5 (Resistance to Tension at Elevated Temperature) |
- |
|
|
|
8.5 (Resistance to Tension at Elevated Temperature) |
- |
|
|
|
8.6 (Resistance to Pull Out of Joints Between Fitting and Emitting
IS 13479) |
- |
|
|
|
8.7.1 (Resistance of PE Emitting Pipe to
Environmental Stress Cracking -Acceptance Test
Annex D of IS 12786) |
- |
|
|
|
8.7.2 (Resistance of PE Emitting Pipe to
Environmental Stress Cracking - Type Test
Annex D of IS 12786) |
- |
|
|
|
8.8 (Determination of Emitting Unit Exponent) |
- |
|
|
|
9.1 (DESIGNATION - Non regulated Emitting Pipe) |
- |
|
|
|
9.2 (DESIGNATION - Regulated Emitting Pipe) |
- |
|
|
|
4.1 a (Identification) |
- |
|
|
|
5.1.2 (Ref. Cl 4.1.c & 4.2.a of IS 12786 : 1989) (Carbon Black content - IS 2530 : 1963) |
- |
|
|
|
5.1.2 (Ref. Cl 4.2.b of IS 12786 : 1989) (The dispersion of Carbon Black content shall be satisfactory - IS 2530 : 1963) |
- |
|
|
|
|
Partial
|
|
- |
- |
20 |
IS 710 (2010) |
Marine plywood - Specification (Second Revision) |
- |
-
|
- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
7.1 (WORKMANSHIP AND FINISH ) |
- |
|
|
|
7.2 (WORKMANSHIP AND FINISH ) |
- |
|
|
|
7.3 (WORKMANSHIP AND FINISH ) |
- |
|
|
|
7.5 (WORKMANSHIP AND FINISH ) |
- |
|
|
|
6.1 (DIMENSIONS) |
- |
|
|
|
6.1 (DIMENSIONS) |
- |
|
|
|
6.2 (DIMENSIONS) |
- |
|
|
|
6.3 (DIMENSIONS) |
- |
|
|
|
6.3 (DIMENSIONS) |
- |
|
|
|
9.1.1 (MOISTURE CONTENT) |
- |
|
|
|
9.1.2 , 9.1.2.1 (Glue Adhesion in Dry State) |
- |
|
|
|
9.1.2 , 9.1.2.2 (Glue Adhesion in Dry State) |
- |
|
|
|
9.1.3 , 9.1.3.1.1 (Water resistance test) |
- |
|
|
|
9.1.3 , 9.1.3.1.2 (Water resistance test) |
- |
|
|
|
9.1.5 (Mycological test) |
- |
|
|
|
9.1.5 , 9.1.3.1.1 (Mycological test) |
- |
|
|
|
9.1.5 , 9.1.3.1.2 (Mycological test) |
- |
|
|
|
9.1.4 (Tensile strength) |
- |
|
|
|
9.1.6 (Table 3) (Static bending strength) |
- |
|
|
|
9.1.6 (Table 3) (Static bending strength) |
- |
|
|
|
9.1.7 (Table 4) (Wet bending strength) |
- |
|
|
|
9.1.7 (Table 4) (Wet bending strength) |
- |
|
|
|
Cl. 9.1.7 (Table 4) (Cl. 9.1.7 (Table 4) (Modulus of Rupture: Across the Face Grain: Minimum Individual)) |
- |
|
|
|
Cl. 9.1.7 (Table 4) (Cl. 9.1.7 (Table 4) (Modulus of Rupture: Across the Face Grain: Average)) |
- |
|
|
|
Cl. 9.1.7 (Table 4) (Cl. 9.1.7 (Table 4) (Modulus of Rupture: Along the Face Grain: Minimum Individual)) |
- |
|
|
|
Cl. 9.1.7 (Table 4) (Cl. 9.1.7 (Table 4) (Modulus of Rupture: Along the Face Grain: Average)) |
- |
|
|
|
Cl. 9.1.7 (Table 4) (Cl. 9.1.7 (Table 4) (Modulus of Elasticity: Across the Face Grain: Minimum Individual)) |
- |
|
|
|
Cl. 9.1.7 (Table 4) (Cl. 9.1.7 (Table 4) (Modulus of Elasticity: Across the Face Grain: Average)) |
- |
|
|
|
Cl. 9.1.7 (Table 4) (Cl. 9.1.7 (Table 4) (Modulus of Elasticity: Along the Face Grain: Minimum Individual)) |
- |
|
|
|
Cl. 9.1.7 (Table 4) (Cl. 9.1.7 (Table 4) (Modulus of Elasticity: Along the Face Grain: Average)) |
- |
|
|
|
Cl. 9.1.6 (Table 3) (Cl. 9.1.6 (Table 3) (Modulus of Rupture: Across the Face Grain: Minimum Individual)) |
- |
|
|
|
Cl. 9.1.6 (Table 3) (Cl. 9.1.6 (Table 3) (Modulus of Rupture: Across the Face Grain: Average)) |
- |
|
|
|
Cl. 9.1.6 (Table 3) (Cl. 9.1.6 (Table 3) (Modulus of Rupture: Along the Face Grain: Minimum Individual)) |
- |
|
|
|
Cl. 9.1.6 (Table 3) (Cl. 9.1.6 (Table 3) (Modulus of Rupture: Along the Face Grain: Average)) |
- |
|
|
|
Cl. 9.1.6 (Table 3) (Cl. 9.1.6 (Table 3) (Modulus of Elasticity: Across the Face Grain: Minimum Individual)) |
- |
|
|
|
Cl. 9.1.6 (Table 3) (Cl. 9.1.6 (Table 3) (Modulus of Elasticity: Across the Face Grain: Average)) |
- |
|
|
|
Cl. 9.1.6 (Table 3) (Cl. 9.1.6 (Table 3) (Modulus of Elasticity: Along the Face Grain: Minimum Individual)) |
- |
|
|
|
Cl. 9.1.6 (Table 3) (Cl. 9.1.6 (Table 3) (Modulus of Elasticity: Along the Face Grain: Average)) |
- |
|
|
|
Cl. 9.1.4 (Cl. 9.1.4 (Tensile Strength: Sum of the Tensile Strength in two directions)) |
- |
|
|
|
Cl. 9.1.4 (Cl. 9.1.4 (Tensile Strength: Perpendicular to grain)) |
- |
|
|
|
Cl. 9.1.4 (Cl. 9.1.4 (Tensile Strength: Parallel to grain)) |
- |
|
|
|
Cl.9.1.5,9.1.3.1.1 (Cl.9.1.5 (Mycological Test),9.1.3.1.1 (Glue Shear Strength: Individual)) |
- |
|
|
|
Cl.9.1.5,9.1.3.1.1 (Cl.9.1.5 (Mycological Test),9.1.3.1.1 ( Glue Shear Strength: Average)) |
- |
|
|
|
Cl. 9.1.3, 9.1.3.1.1 (Cl. 9.1.3 (Water Resistance Test) , 9.1.3.1.1 (Glue Shear Strength: Individual)) |
- |
|
|
|
Cl. 9.1.3, 9.1.3.1.1 (Cl. 9.1.3 (Water Resistance Test ), 9.1.3.1.1 (Glue Shear Strength: Average)) |
- |
|
|
|
Cl. 9.1.2, 9.1.2.1 (Cl. 9.1.2 (Glue Adhesion in Dry State), 9.1.2.1 ( Glue Shear Strength: Individual)) |
- |
|
|
|
Cl. 9.1.2, 9.1.2.1 (Cl. 9.1.2 (Glue Adhesion in Dry State), 9.1.2.1 ( Glue Shear Strength: Average )) |
- |
|
|
|
|
Partial
|
|
- |
- |
21 |
IS 303 (1989) |
Plywood for General Purposes - |
- |
-
|
- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
4 (Grade - For BWR grade) |
- |
|
|
|
4 (Grade - For MR grade) |
- |
|
|
|
5.1 (Type - For AA Type) |
- |
|
|
|
5.1 (Type - For AB Type) |
- |
|
|
|
5.1 (Type - For BB Type) |
- |
|
|
|
5.2, Table 1, Table 2 (Quality Requirements - Cl. 5.2) |
- |
|
|
|
9 (Workmanship and Finish - Cl.9, 8.3, Annexure C) |
- |
|
|
|
9 (Workmanship and Finish - Cl.9, 8.3, Annexure C) |
- |
|
|
|
8 (Dimensions & Tolerances - Length - Cl. 8) |
- |
|
|
|
8 (Dimensions & Tolerances - Width - Cl. 8) |
- |
|
|
|
8 (Dimensions & Tolerances - Thickness - Cl. 8) |
- |
|
|
|
8 (Dimensions & Tolerances - Squareness - Annexure C) |
- |
|
|
|
8 (Dimensions & Tolerances - Edge Straightness - Annexure C) |
- |
|
|
|
11.3 (Moisture Content - Part 1 of IS 1734) |
- |
|
|
|
11.2.1 (Glue Adhesion - Water resistance test - 11.2.1.1 [for BWR Grade]) |
- |
|
|
|
11.2.1 (Glue Adhesion - Water resistance test - 11.2.1.1 [for MR Grade]) |
- |
|
|
|
11.2.2 (Glue Adhesion - Mycological test - 11.2.2, Part 7 of IS 1734 [for MR Garde only]) |
- |
|
|
|
11.4, Table 4 (Static Bending Strength - Modulus of Elasticity - Along the Face Grain - Average) |
- |
|
|
|
11.4, Table 4 (Static Bending Strength - Modulus of Elasticity - Along the Face Grain - Minimum Individual) |
- |
|
|
|
11.4, Table 4 (Static Bending Strength - Modulus of Elasticity - Across the Face Grain - Average) |
- |
|
|
|
11.4, Table 4 (Static Bending Strength - Modulus of Elasticity - Across the Face Grain - Minimum Individual) |
- |
|
|
|
11.4, Table 4 (Static Bending Strength - Modulus of Rupture - Along the Face Grain - Average) |
- |
|
|
|
11.4, Table 4 (Static Bending Strength - Modulus of Rupture - Along the Face Grain - Minimum Individual) |
- |
|
|
|
11.4, Table 4 (Static Bending Strength - Modulus of Rupture - Across the Face Grain - Average) |
- |
|
|
|
11.4, Table 4 (Static Bending Strength - Modulus of Rupture - Across the Face Grain - Minimum Individual) |
- |
|
|
|
|
Partial
|
|
- |
- |
22 |
IS 6614 (2021) |
SPECIFICATION FOR ALUMINIUM CHLORIDE ANHYDROUS TECHNICAL First revision of IS 6614 |
- |
-
|
- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Cl-3.1 (Description) |
- |
|
|
|
Cl-3.2,Table1,sl.no-i (Insoluble matter) |
- |
|
|
|
Cl-3.2,Table 1,sl.no-ii (Assay as AlCl3) |
- |
|
|
|
Cl-3.2,Table 1,sl.no-iii (Total Aluminium as Al) |
- |
|
|
|
Cl-3.2,Table 1,sl.no-iv (Free Aluminium as Al) |
- |
|
|
|
Cl-3.2,Table 1,sl.no-v (Iron as Fe) |
- |
|
|
|
Cl-3.2,Table 1,sl.no-vi,a (Solubility -Ether) |
- |
|
|
|
Cl-3.2,Table 1,sl.no-vi,b (Solubility-Nitrobenzene) |
- |
|
|
|
|
Partial
|
|
- |
- |
23 |
IS 248 (2023) |
SODIUM BISULPHITE TECHNICAL SODIUM METABISULPHITE SPECIFICATION |
- |
-
|
- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Cl-3.1 (Description) |
- |
|
|
|
Cl-3.2,Table 1,sl.no-i (Purity (as SO2 content)) |
- |
|
|
|
Cl-3.2,Table 1,sl.no-ii (pH of 5 percent solution) |
- |
|
|
|
Cl-3.2,Table 1,sl.no-iii (Matter insoluble in water) |
- |
|
|
|
Cl-3.2,Table 1,sl.no-iv (Iron (as Fe),) |
- |
|
|
|
Cl-3.2,Table 1,sl.no-v (Heavy metals (as Pb),) |
- |
|
|
|
Cl-3.2,Table 1,sl.no-vi (Appearance of solution) |
- |
|
|
|
|
Partial
|
|
- |
- |
24 |
IS 10523 (2014) |
Baby toilet soap - Specification (First Revision) |
- |
-
|
- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Cl-4.3,Table 1,sl.no-i (Total Fatty matter) |
- |
|
|
|
Cl-4.3,Table 1,sl.no-ii (Moisture and volatile Matter) |
- |
|
|
|
Cl-4.3,Table 1,sl.no-iii (Matter insoluble in alcohol) |
- |
|
|
|
Cl-4.3,Table 1,sl.no-iv (Matter insoluble in water) |
- |
|
|
|
Cl-4.3,Table 1,sl.no-v (Free caustic alkali as sodium hydroxide) |
- |
|
|
|
Cl-4.3,Table 1,sl.no-vi (Chloride) |
- |
|
|
|
Cl-4.3,Table 1,sl.no-vii (Free Carbonated alkali) |
- |
|
|
|
Cl-4.3,Table 1,sl.no-viii (Freedom from Rosin) |
- |
|
|
|
Cl-4.3,Table 1,sl.no-ix (Freedom from grit) |
- |
|
|
|
Cl-4.3,Table 1,sl.no-x (Nickel content) |
- |
|
|
|
Cl-4.3,Table 1,sl.no-xi (Iron content) |
- |
|
|
|
Cl-4.3,Table 1,sl.no-xii (Copper Content) |
- |
|
|
|
|
Partial
|
|
- |
- |
25 |
IS 15500 : Part 1 to 8 (2021) |
Deepwell Handpumps Components and Special Tools Specification |
- |
-
|
- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
No Record Found
|
|
Partial
|
|
- |
Exclusion
Except Material Testing. |
26 |
IS 15500 : PART 2 (2021) |
Deepwell Handpumps, Components and Secial Tools — Specification Part 2 Handpumps |
- |
-
|
- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
2 (CONSTRUCTION) |
- |
|
|
|
2.1 ("The assembly detail of different types of handpumps
covered in this part shall be as given in Fig. 2.1 to 2.5.") |
- |
|
|
|
2.1 ("The assembly detail of different types of handpumps
covered in this part shall be as given in Fig. 2.1 to 2.5.") |
- |
|
|
|
2.2 ("2.2 The material and dimensions of the individual
component shall meet the requirements given in the
related part of this standard.") |
- |
|
|
|
3 (TESTING) |
- |
|
|
|
3.3.1 (Head and Cylinder Assemblies) |
- |
|
|
|
3.3.2 (Other Components) |
- |
|
|
|
|
Partial
|
|
- |
Exclusion
Except Material Testing. |
27 |
IS 8249 (2019) |
Zinc sulphate heptahydrate, agricultural grade - Specification (First Revision) |
- |
-
|
- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
3.1 (Description) |
- |
|
|
|
Cl-3.2 & 6.2,Table 1,sl.no-i (Matter insoluble in water) |
- |
|
|
|
(Clauses 3.2 and 6.2) Table 1 (Zinc (as Zn)) |
- |
|
|
|
(Clauses 3.2 and 6.2) Table 1 (Lead (as Pb)) |
- |
|
|
|
(Clauses 3.2 and 6.2) Table 1 (Copper (as Cu)) |
- |
|
|
|
(Clauses 3.2 and 6.2) Table 1 (Magnesium (as Mg)) |
- |
|
|
|
(Clauses 3.2 and 6.2) Table 1 (pH) |
- |
|
|
|
(Clauses 3.2 and 6.2) Table 1 (Sulphur (as S)) |
- |
|
|
|
(Clauses 3.2 and 6.2) Table 1 (Cadmium (as Cd)) |
- |
|
|
|
(Clauses 3.2 and 6.2) Table 1 (Arsenic (as As)) |
- |
|
|
|
|
Partial
|
|
- |
- |
28 |
IS 711 (1970) |
Specification for ferric choride, technical (First Revision) |
- |
-
|
- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
3.1 (Description) |
- |
|
|
|
Cl.3.2, Table-1(i) (Relative density(For liquid)) |
- |
|
|
|
Cl.3.2, Table-1(ii) (Ferric chloride (as FeCl3)) |
- |
|
|
|
Cl-3.2, Table 1, sl.no-iii (Free acid/ basicity) |
- |
|
|
|
Cl-3.2, Table 1, sl.no-iv (Ferrous salts) |
- |
|
|
|
Cl.3.2, Table-1(v) (Insoluble matter) |
- |
|
|
|
Cl-3.2, Table 1, sl.no-vi (Free chlorine) |
- |
|
|
|
Cl-3.2, Table 1, sl.no-vii (Sulphates) |
- |
|
|
|
Cl.3.2, Table-1(viii) (Nitrates (as NO3)) |
- |
|
|
|
Cl-3.2, Table 1, sl.no-ix (Alkalis and alkaline earths) |
- |
|
|
|
Cl.3.2, Table-1(x) (Copper (as Cu)) |
- |
|
|
|
Cl.3.2, Table-1(xi) (Zinc (as Zn)) |
- |
|
|
|
|
Partial
|
|
- |
- |
29 |
IS 2802 (1964) |
Specification for ice-cream |
- |
-
|
- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
4.1 Table 1 (Coliform Count) |
- |
|
|
|
4.1 Table 1 (Total Colony Count) |
- |
|
|
|
|
Partial
|
|
- |
Exclusion
Except Phosphatase test |
30 |
IS 694 (2010) |
Polyvinyl chloride insulated unsheathed and sheathed cables/cords with rigid and flexible conductor for rated voltages up to and including 450/750 v (Fourth Revision) |
Cat 01 & Cat 02 excluding FR & FRLSH |
-
|
- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
13 (Cable code) |
- |
|
|
|
11.2 (Legibility) |
- |
|
|
|
11.1 (Durability) |
- |
|
|
|
11 (Identification) |
- |
|
|
|
10.9 (Additional ageing test (OU cables only) -HV test (at 60±3oC)) |
- |
|
|
|
10.4 (Flammability test- Unaffected portion) |
- |
|
|
|
10.4 (Flammability test-Burning after flame removal) |
- |
|
|
|
table 1 e) 3) (IR constant- max. Temp) |
- |
|
|
|
table 1 e) 3) (IR constant- Room temp ) |
- |
|
|
|
table 1 e) 3) (Volume Resistivity - Maximum temp) |
- |
|
|
|
table 1 e) 3) (Volume Resistivity - Room temp ) |
- |
|
|
|
10.2 (HV (room temperature)) |
- |
|
|
|
10.1 (HV (water immersion)) |
- |
|
|
|
10.1 (HV (water immersion)) |
- |
|
|
|
Table 1 iii) d) 9) (Cold impact for sheath) |
- |
|
|
|
Table 1 iii) d) 8) (Cold bend for sheath) |
- |
|
|
|
Table 1 iii) c) 9) (Cold impact for insulation) |
- |
|
|
|
Table 1 iii) c) 8) (Cold bend for insulation) |
- |
|
|
|
Table 1 (Category Code) |
- |
|
|
|
Table 1 iii) d) 7) (Thermal stability- Sheath ) |
- |
|
|
|
Table 1 iii) c) 7) (Thermal stability- Insulation ) |
- |
|
|
|
Table 1 iii) d) 6) (Hot deformation -Indentation depth - Sheath ) |
- |
|
|
|
Table 1 iii) d) 5) (Heat shock-Sheath ) |
- |
|
|
|
Table 1 iii) c) 5) (Heat shock-Insulation ) |
- |
|
|
|
Table 1 iii) d) 4) (Cracks Observed) |
- |
|
|
|
Table 1 iii) d) 4) (Shrinkage- Sheath ) |
- |
|
|
|
Table 1 iii) c) 4) (Cracks Observed) |
- |
|
|
|
Table 1 iii) c) 4) (Shrinkage-Insulation) |
- |
|
|
|
Table 1 iii) d) 2) (Loss of mass- Sheath ) |
- |
|
|
|
Table 1 iii) c) 2) (Loss of mass- Insulation ) |
- |
|
|
|
Table 1 iii) d) 3) (Sheath- Elongation variation) |
- |
|
|
|
Table 1 iii) d) 3) (Sheath- TS variation) |
- |
|
|
|
Table 1 iii) d) 3) (Sheath- Elongation (After ageing)) |
- |
|
|
|
Table 1 iii) d) 3) (Sheath- Tensile strength (After ageing)) |
- |
|
|
|
Table 1 iii) d) 1) (Sheath- Elongation (Without ageing)) |
- |
|
|
|
Table 1 iii) d) 1) (Sheath -Tensile strength (Without ageing)) |
- |
|
|
|
Table 1 iii) c) 3) (Elongation variation) |
- |
|
|
|
Table 1 iii) c) 3) (TS variation) |
- |
|
|
|
Table 1 iii) c) 3) (Elongation (After ageing)) |
- |
|
|
|
Table 1 iii) c) 3) (Tensile strength (After ageing)) |
- |
|
|
|
Table 1 iii) c) 1) (Elongation (Without ageing)) |
- |
|
|
|
Table 1 iii) c) 1) (Tensile strength (Without ageing)) |
- |
|
|
|
(Cl. 18.1.4)
(Cl. 19.1.5)
(Cl. 20.1.4)
(Cl. 22.1.4) (Colour of Sheath) |
- |
|
|
|
8.3 (Thickness of Sheath) |
- |
|
|
|
5.2 (Application ) |
- |
|
|
|
5.3 (Thickness of Insulation) |
- |
|
|
|
9.1 (Ovality) |
- |
|
|
|
9 (Overall dimensions) |
- |
|
|
|
4.2 (Conductor resistance test) |
- |
|
|
|
4.1 (Wrapping test (for Al)) |
- |
|
|
|
4.1 (Tensile test (for Al)- After Stranding) |
- |
|
|
|
4.1 (Tensile test (for Al)-Before Stranding) |
- |
|
|
|
4.1 (Annealing test (for copper)) |
- |
|
|
|
(Cl.6.1.3 of IS 8130:2013) (Flexible Conductors (Classes 5)) |
- |
|
|
|
(Cl.6.1.3 of IS 8130:2013) (Stranded circular non compacted conductors(Class-2)) |
- |
|
|
|
(Cl.6.1.3 of IS 8130:2013) (Stranded compacted circular conductors and shaped conductors (Class 2)) |
- |
|
|
|
(Cl.6.1.3 of IS 8130:2013) (Solid Conductor (Class 1)) |
- |
|
|
|
(Cl.6.1 of IS 8130:2013) (Solid Conductor (Class 1)) |
- |
|
|
|
(Cl.16.1)
(Cl.19.1) (Conductor- Diameter ) |
- |
|
|
|
(Cl. 18.1.3)
(Cl. 19.1.4)
(Cl. 20.1.3)
(Cl. 21.1.3)
(Cl. 22.1.3) (Assembly of cores ) |
- |
|
|
|
12 (CONSTRUCTION Core Identification) |
- |
|
|
|
8.1 (Sheath Material ) |
- |
|
|
|
7 (Binder Tape) |
- |
|
|
|
6.2 (Filler) |
- |
|
|
|
6.1 (Filler) |
- |
|
|
|
5.1 (Insulation) |
- |
|
|
|
4.4 (Joints in Conductor) |
- |
|
|
|
4.4 (Joints in Conductor) |
- |
|
|
|
4.1 (Conductor - Material) |
- |
|
|
|
4.1 (Conductor - Material) |
- |
|
|
|
12.0 (Core identification) |
- |
|
|
|
4, IS 8130 (Construction of conductor) |
- |
|
|
|
Table 2, IS 8130 (No fo wire in a conductor) |
- |
|
|
|
8.3 (Minimum thickness of Sheath) |
- |
|
|
|
8.3 (Avarage thickness of Sheath) |
- |
|
|
|
5.3 (Minimum thickness of insulation) |
- |
|
|
|
5.3 (Avarage thickness of insulation) |
- |
|
|
|
table 1, 4.2 (insulation resistance test) |
- |
|
|
|
5.4 (Mechanical properties before and after ageing) |
- |
|
|
|
|
Partial
|
|
- |
Testing facility Complete for Cat 01, 02 except FR & FRLSH. Test facility not available for Chemical tests - Copper Purity test and Persulphate tests. |