1 |
IS 16270 (2014) |
Secondary cells and batteries for solar photovoltaic application - General requirements and methods of test |
- |
-
|
400000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
4(Condition of use) |
- |
2000 |
|
NA |
5.1(Mechanical Endurance) |
- |
1000 |
|
NA |
5.2(Charge efficiency) |
- |
1000 |
|
NA |
5.3(Deep discharge protection) |
- |
0 |
|
NA |
5.4(Marking) |
- |
4000 |
|
NA |
5.5(Dafety) |
- |
0 |
|
NA |
5.6(Documentation) |
- |
0 |
|
NA |
6(Finctional Characteristics) |
- |
0 |
|
NA |
7(General test conditions) |
- |
0 |
|
NA |
8.1(Capacity test) |
- |
20000 |
|
NA |
8.2(Endurance test) |
- |
140000 |
|
NA |
8.3(Charge retention test) |
- |
10000 |
|
NA |
8.4(Cycle endurance in Photovoltaic application) |
- |
200000 |
|
NA |
8.5(Sulphation Test) |
- |
10000 |
|
NA |
8.6(Water loss test) |
- |
10000 |
|
NA |
8.7(Non spillability) |
- |
2000 |
|
NA |
|
Complete
|
|
10 Mar, 2027 |
- |
2 |
IS 16046 : Part 2 (2018) |
Secondary Cells and Batteries Containing Alkaline or Other Non-Acid Electrolytes ” Safety Requirements for Portable Sealed Secondary Cells and for Batteries Made from Them for Use in Portable Applications Part 2 Lithium Systems ( Second Revision ) |
- |
-
|
60000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
4(Parameter Measurement Tolerances) |
- |
0 |
|
NA |
5(General Safety Considerations) |
- |
0 |
|
NA |
5.1(General) |
- |
0 |
|
NA |
5.2(Insulation and Wiring) |
- |
0 |
|
NA |
5.3(Venting) |
- |
1500 |
|
NA |
5.4(Temperature, Voltage and Current Management) |
- |
100 |
|
NA |
5.5(Terminal Contacts) |
- |
1500 |
|
NA |
5.6(Assembly of Cells into batteries) |
- |
0 |
|
NA |
5.7(Quality Plan) |
- |
0 |
|
NA |
5.8(Battery Safety Components) |
- |
0 |
|
NA |
6(Type Test and Sample Size) |
- |
0 |
|
NA |
7(Specific requirements and tests) |
- |
0 |
|
NA |
7.1(Charging procedure for test purposes) |
- |
12500 |
|
NA |
7.2(Intended Use) |
- |
14500 |
|
NA |
7.3(Reasonably foreseeable misuse) |
- |
20500 |
|
NA |
8(Information for safety) |
- |
1500 |
|
NA |
8.1(General) |
- |
0 |
|
NA |
8.2(Small Cell and battery safety information) |
- |
0 |
|
NA |
9(Marking) |
- |
0 |
|
NA |
9.1(Cell Marking) |
- |
0 |
|
NA |
9.2(Battery Marking) |
- |
0 |
|
NA |
9.3(Caution for ingestion of small cells and batteries) |
- |
0 |
|
NA |
9.4(Other information) |
- |
0 |
|
NA |
10(Packaging) |
- |
1000 |
|
NA |
|
Complete
|
|
10 Mar, 2027 |
- |
3 |
IS 16169 (2014) |
Utility - Interconnected photovoltaic inverters - Test procedure of islanding prevention measures |
- |
-
|
100000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
6, (Elec)(Test for single or multi-phase inverter) |
- |
55000 |
|
NA |
7(Documentation) |
- |
10000 |
|
NA |
6 to 6.2, (Elec)(Test for single or multi-phase inverter to Pass/fail criteria) |
- |
35000 |
|
NA |
6(Test for single or multi-phase inverter) |
- |
45000 |
|
- |
7(Documentation) |
- |
10000 |
|
- |
6 to 6.2(Test for single or multi-phase inverter to Pass/fail criteria) |
- |
45000 |
|
- |
|
Complete
|
|
10 Mar, 2027 |
- |
4 |
IS 16221 : Part 1 (2016) |
Safety of Power Converters for use in Photovoltaic Power Systems Part 1 General Requirements |
- |
-
|
270000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
4(General testing requirements) |
- |
70000 |
|
NA |
5(Marking and documentation) |
- |
20000 |
|
NA |
6(Environmental Requirements and conditions) |
- |
10000 |
|
NA |
7(Protection against electric shock and energy hazards) |
- |
70000 |
|
NA |
8(Protection Against mechanical Hazards) |
- |
10000 |
|
NA |
9(Protection Against Fire Hazards) |
- |
10000 |
|
NA |
10(Protection against Sonic Pressure hazards) |
- |
4000 |
|
NA |
11(Protection against liquid hazards) |
- |
4000 |
|
NA |
12(Chemical hazards) |
- |
2000 |
|
NA |
13(Physical requirements) |
- |
70000 |
|
NA |
14(Components) |
- |
1000 |
|
NA |
15(Software and firmware performing safety functions) |
- |
1000 |
|
NA |
|
Complete
|
|
10 Mar, 2027 |
- |
5 |
IS 16221 : Part 2 (2015) |
Safety of power converters for use in photovoltaic power systems: Part 2 particular requirements for inverters |
- |
-
|
170000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
4(General Test Requireements) |
- |
395000 |
|
NA |
5(Marking and documentation) |
- |
5000 |
|
NA |
6(Environmental requirements and conditions) |
- |
5000 |
|
NA |
7(Protection against electric shock and energy hazards) |
- |
5000 |
|
NA |
8(Protection against Mechanical Hazards) |
- |
5000 |
|
NA |
9(Protection against Fire Hazards) |
- |
5000 |
|
NA |
11(Protection against Liquid Hazards) |
- |
5000 |
|
NA |
12(Protection against Chemical Hazards) |
- |
5000 |
|
NA |
10(Protection against Sonic Pressure Hazards) |
- |
5000 |
|
NA |
13(Physical Requirements) |
- |
5000 |
|
NA |
14(Components) |
- |
0 |
|
NA |
|
Complete
|
|
10 Mar, 2027 |
- |
6 |
IS 616 (2017) |
Audio, video and similar electronic apparatus - Safety requirements (Fifth Revision) |
- |
-
|
65000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
5(Marking and instructions) |
- |
2000 |
|
NA |
6(Hazardous radiations) |
- |
2000 |
|
NA |
7(Heating under normal operating conditions) |
- |
2000 |
|
NA |
8(Constructional requirements with regard to the protection against electric shock) |
- |
2000 |
|
NA |
9(Electric shock hazard under normal operating conditions) |
- |
5000 |
|
NA |
10(Insulation requirements) |
- |
15000 |
|
NA |
11(Fault conditions) |
- |
2000 |
|
NA |
12(Mechanical strength) |
- |
15000 |
|
NA |
13(CLEARANCES and CREEPAGE DISTANCES) |
- |
5000 |
|
NA |
15(TERMINALS) |
- |
2000 |
|
NA |
16(External flexible cords) |
- |
1000 |
|
NA |
17(Electrical connections and mechanical fixings) |
- |
2000 |
|
NA |
19(Stability and mechanical hazards) |
- |
5000 |
|
NA |
20(Resistance to fire) |
- |
2000 |
|
NA |
14(Components) |
- |
1000 |
|
NA |
|
Complete
|
|
10 Mar, 2027 |
- |
7 |
IS 16169 (2019) |
Utility - Interconnected photovoltaic inverters - Test procedure of islanding prevention measures (First Revision) |
- |
-
|
100000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
6(Test for single or multi-phase inverter) |
- |
80000 |
|
- |
Annex A(Islanding as it applies to PV systems) |
- |
10000 |
|
- |
Annex B(Test for independent islanding device) |
- |
10000 |
|
- |
|
Complete
|
|
10 Mar, 2027 |
IS Included w.e.f. 07-09-2020 |
8 |
IS 13252 : Part 1 (2010) |
Information technology equipment - Safety: Part 1 general requirements (Second Revision) |
- |
-
|
65000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
1.6(Power interface .) |
- |
1200 |
|
- |
1.7(Markings and instructions) |
- |
800 |
|
- |
2.1(Protection from electric shock and energy hazards) |
- |
6000 |
|
- |
2.2(SELV circuits) |
- |
2400 |
|
- |
2.3(TNV circuits) |
- |
7000 |
|
- |
2.4(Limited current circuits) |
- |
1000 |
|
- |
2.5(Limited power sources .) |
- |
1000 |
|
- |
2.6(Provisions for earthing and bonding) |
- |
1000 |
|
- |
2.7(Overcurrent and earth fault protection in primary circuits) |
- |
1000 |
|
- |
2.8(Safety interlocks) |
- |
1000 |
|
- |
2.9(Electrical insulation) |
- |
12000 |
|
- |
2.10(Clearances, creepage distances and distances through insulation) |
- |
6800 |
|
- |
3.1(General) |
- |
500 |
|
- |
3.2(Connection to a mains supply) |
- |
1200 |
|
- |
3.3(Wiring terminals for connection of external conductors) |
- |
500 |
|
- |
3.4(Disconnection from the mains supply) |
- |
500 |
|
- |
3.5(Interconnection of equipment) |
- |
500 |
|
- |
4.1(Stability) |
- |
1200 |
|
- |
4.2(Mechanical strength) |
- |
3700 |
|
- |
4.3(Design and construction) |
- |
1000 |
|
- |
4.4(Protection against hazardous moving parts) |
- |
400 |
|
- |
4.5(Thermal requirements) |
- |
2400 |
|
- |
4.6(Openings in enclosures) |
- |
1200 |
|
- |
4.7(Resistance to fire) |
- |
1000 |
|
- |
5.1(Touch current and protective conductor curren) |
- |
1200 |
|
- |
5.2(Electric strength) |
- |
1500 |
|
- |
5.3(Abnormal operating and fault conditions) |
- |
3000 |
|
- |
6.1(Protection of telecommunication network service persons, and users of other equipment connected to the network, from hazards in the equipment) |
- |
1000 |
|
- |
6.2(Protection of equipment users from overvoltages on networks telecommunication) |
- |
500 |
|
- |
6.3(Protection of the telecommunication wiring system from overheating) |
- |
500 |
|
- |
7.1(General) |
- |
500 |
|
- |
7.2(Protection of cable distribution system service persons, and users of other equipment connected to the system, from hazardous voltages in the equipment) |
- |
500 |
|
- |
7.3(Protection of equipment users from overvoltages on the cable distribution system) |
- |
500 |
|
- |
7.4(Insulation between primary circuits and cable distribution systems) |
- |
500 |
|
- |
1.5(Components) |
- |
0 |
|
- |
|
Complete
|
|
10 Mar, 2027 |
- |
9 |
IS 16242 : Part 1 (2014) |
Uninterruptible power systems (UPS): Part 1 general and safety requirements for UPS |
- |
-
|
65000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
4.5(Components) |
- |
1500 |
|
- |
4.6(Power interface) |
- |
1500 |
|
- |
4.7(Marking & instructions) |
- |
3000 |
|
- |
5.1(Protection against shock and energy hazards) |
- |
3000 |
|
- |
5.2(Requirement of auxiliary circuits) |
- |
10000 |
|
- |
5.3(Protective earthing and bonding) |
- |
3000 |
|
- |
5.4(AC and DC power isolation) |
- |
1500 |
|
- |
5.5(Over current and earth fault condition) |
- |
1500 |
|
- |
5.6(Safety interlocks) |
- |
1500 |
|
- |
5.7(CLEARANCES, CREEPAGE DISTANCES AND SOLID INSULATION) |
- |
4000 |
|
- |
6.1(Wiring, connections and supply) |
- |
1500 |
|
- |
6.2(Connection to power) |
- |
1500 |
|
- |
6.3(Wiring terminals for external power conductors) |
- |
1500 |
|
- |
7.1(Enclosure) |
- |
1500 |
|
- |
7.2(STABILITY) |
- |
1500 |
|
- |
7.3(MECHANICAL STRENGTH) |
- |
5500 |
|
- |
7.4(Construction details) |
- |
1500 |
|
- |
7.5(Resistance to fire) |
- |
1500 |
|
- |
7.6(Battery location) |
- |
1500 |
|
- |
7.7(Temperature rise) |
- |
1500 |
|
- |
8.1(General procision for earth leakage) |
- |
1500 |
|
- |
8.2(Electric Strength) |
- |
1500 |
|
- |
8.3(Abnormal operating and fault conditions) |
- |
5000 |
|
- |
9.0(Connection to telecommunication networks) |
- |
4000 |
|
- |
|
Complete
|
|
10 Mar, 2027 |
IS Included w.e.f. 13/3/2018
Excluding following tests:
Components (cl.4.5/RD 1.5);
Moving parts (cl.5.6/RD 2.8.5);
Overload test (cl.5.6/RD 2.8.7.2);
Endurance test (cl.5.6/RD 2.8.7.3);
Semi-conductor devices (cl.5.7/RD 2.10.5.4);
Insulation in wound components
(cl.5.7/RD 2.10.5.11);
Construction of printed circuit boards (cl.5.7/RD/ 2.10.6);
Test on coated printed boards and coated components (cl.5.7/RD 2.10.8);
Thermal cycling (cl.5.7/ RD 2.10.9);
Test for pollution degree 1 environment and for insulating components (cl.5.7/RD 2.10.10);
Enclosed sealing parts (cl.5.7/RD 2.10.12);
Resistance to fire-Flammability test (cl.7.5, Annex A);
Ventilation (cl. 7.6.7 & Annex M) |