2 |
IS/IEC 60079 : Part 1 (2014) |
Explosive Atmospheres - Part 1 : Equipment Protection by Flameproof Enclosures "d" |
- |
-
|
200000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
15.2.2(Determination of explosion pressure (reference pressure)) |
- |
75000 |
|
For enclosure:Up to 5 lit-25,000/-, 5to15 lit-30,000/-,15to50 lit- 50,000/-, 50-100 Lit -65000/-,Above 100 lit - on request
Rotating Electrical Machines: up to 112 frames size-28500, from 112 to 280 frame 38500/-, frame size 280 and above -75000.00/-. |
15.2.3.2(Overpressure test – First method (static)) |
- |
3000 |
|
per sample |
15.3.1(Test for non-transmission of an internal ignition) |
- |
75000 |
|
For enclosure:Up to 5 lit-25,000/-, 5to15 lit-30,000/-,15to50 lit- 50,000/-, 50-100 Lit -65000/-,Above 100 lit - on request
Rotating Electrical Machines: up to 112 frames size-28500, from 112 to 280 frame 38500/-, frame size 280 and above -75000.00/-. |
15.3.2(Electrical equipment of Groups I, IIA and IIB) |
- |
75000 |
|
For enclosure:Up to 5 lit-25,000/-, 5to15 lit-30,000/-,15to50 lit- 50,000/-, 50-100 Lit -65000/-,Above 100 lit - on request
Rotating Electrical Machines: up to 112 frames size-28500, from 112 to 280 frame 38500/-, frame size 280 and above -75000.00/-. |
15.3.3(Electrical equipment of Groups I, IIA and IIB) |
- |
75000 |
|
For enclosure:Up to 5 lit-25,000/-, 5to15 lit-30,000/-,15to50 lit- 50,000/-, 50-100 Lit -65000/-,Above 100 lit - on request
Rotating Electrical Machines: up to 112 frames size-28500, from 112 to 280 frame 38500/-, frame size 280 and above -75000.00/-. |
15.4.2(Tests of ability of the enclosure to withstand pressure) |
- |
75000 |
|
For enclosure:Up to 5 lit-25,000/-, 5to15 lit-30,000/-,15to50 lit- 50,000/-, 50-100 Lit -65000/-,Above 100 lit - on request
Rotating Electrical Machines: up to 112 frames size-28500, from 112 to 280 frame 38500/-, frame size 280 and above -75000.00/-. |
19.3(Observation) |
- |
125000 |
|
Up to 15 lit - 60,000.00
15 to 40 lit - 90,000.00
above 40 lit - 1,25,000.00 |
19.4(Test of erosion by flame) |
- |
125000 |
|
Up to 15 lit - 60,000.00
15 to 40 lit - 90,000.00
above 40 lit - 1,25,000.00 |
C.3.1(Observation) |
- |
25000 |
|
up to 2" entry - 15,000.00
2" to 5" entry - 20,000.00
above 5" entry - 25,000.00 |
C.3.2(Observation) |
- |
6000 |
|
per sample |
C.3.3.1(Torque) |
- |
2000 |
|
per sample |
C.3.3.2(Pressure) |
- |
3000 |
|
per sample |
C.3.4.1(Torque) |
- |
2000 |
|
per sample |
C.3.4.2(Observation) |
- |
3000 |
|
per sample |
C.3.4.3(Pressure) |
- |
3000 |
|
per sample |
15.2.2(Pressure) |
- |
75000 |
|
For enclosure:Up to 5 lit-25,000/-, 5to15 lit-30,000/-,15to50 lit- 50,000/-, 50-100 Lit -65000/-,Above 100 lit - on request
Rotating Electrical Machines: up to 112 frames size-28500, from 112 to 280 frame 38500/-, frame size 280 and above -75000.00/-. |
15.4(Tests of flameproof enclosures with breathing and draining devices) |
- |
85000 |
|
per sample |
B.1, B.2 & B.3(Observation) |
- |
9000 |
|
Per sample |
5(Flameproof joints) |
- |
5000 |
|
Per sample |
|
Complete
|
|
02 Feb, 2028 |
- - |
3 |
IS/IEC 60079 : PART 0 (2017) |
Explosive Atmospheres Part 0 Equipment — General Requirements ( Third Revision ) |
- |
-
|
201000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
26.4.2(Observation) |
- |
3000 |
|
per sample |
26.4.3(Observation) |
- |
1500 |
|
per sample |
26.4.5(Observation) |
- |
12500 |
|
Up to 10 lit 7000.00
10 to 20 lit 9000.00
above 20 lit 12,500.00 |
26.5.1(Voltage, Current, Power, Torque, Speed, Temperature) |
- |
15000 |
|
Clause 26.5.1 Thermal Test
Clause no 26.5.1.2 Service Temperature=7500.00
Clause no 26.5.1.3 Maximum Surface Temperature=7500.00. |
26.5.2(Observation) |
- |
2500.00 |
|
per sample |
26.6(Torque) |
- |
2000 |
|
per sample |
26.8(Temperature) |
- |
95000 |
|
per sample |
26.9(Temperature) |
- |
95000 |
|
per sample |
26.12(Resistance) |
- |
25000 |
|
per sample |
26.13(Insulation resitance) |
- |
15000 |
|
per sample |
26.14(Capacitance) |
- |
2500 |
|
per sample |
26.15(Power, Current, Speed) |
- |
15000 |
|
per sample |
26.16(Dimension) |
- |
25000 |
|
per sample |
A.3.1, A.3.2(Observation) |
- |
6000 |
|
per sample |
A.3.3(Observation) |
- |
3000 |
|
per sample |
A.3.4(Observation) |
- |
12500 |
|
per sample |
|
Complete
|
|
02 Feb, 2028 |
- - |