S.No. Indian Standard No. Product Grade / Type / Size / Designation etc. Testing Charges (Excl. Of Taxes) Validity Date Remark
331 IS 12600 (1989) Portland cement, low heat - specification - - View breakup
-
- -
Facility not available for heat of hydration test & TransverseĀ strength
332 IS 280 (2006) Mild steel wire for general engineering purposes (Fourth Revision) For all sizes except tests mentioned in remarks Rs.3750.00 View breakup
-
- -
Chem- Facility not available for Al (when Al- killed), Also see status for IS 7887
333 IS 12367 (1988) Specification for cold - Rolled carbon steel strips/coils for manufacture of welded tubes All grades/varieties - View breakup
-
- -
Grade to be declared. Chem- Facility not available for Al, V, Nb, Ti, B & Mo. Type of killing and grade to be declared
334 IS 1239 : Part 2 (2011) Steel tubes, tubulars and other steel fittings - Specification: Part 2 steel pipe fittings (Fifth Revision) All types/sizes (pl see remarks) 3400 View breakup
-
- -
Mech- Facility not available for Cl 11.1 (Hydrostatic or pneumatic), Taper screw plug test (Cl 11.2.2). Method of manufacture, type and size designation to be declared.
335 IS 5950 (1984) Specification for shot firing cables (For Use Other Than In Shafts) (First Revision) all sizes/varieties Rs 11030/- View breakup
-
- -
Complete
336 IS 14255 (1995) Aertal bunched cables - For working voltages up to and including 1100 Volts - Specification complete for Cat 01(Except melt flow, vicat, bending) - View breakup
-
- -
Facility not available for breaking load of messenger conductor, Carbon Black test, Vicat Test, Environmental stress cracking for PE insulation. For XLPE water absorption test facility available upto 25 sq.mm. (Facility for nominal area of conductor, Tensile & Elongation above 2.0 mm thickness is not available). 5 mtr Aluminium wire before stranding to be provided additionally.
337 IS 15997 (2012) Low nickel austenitic stainless steel sheet and strip for utensils and kitchen appliances - Specification All types (please see remarks) Rs 2850 View breakup
-
- -
Mech-Type of conditioning, heat treatment, grade, form size,finish to be declared.Chem- Facility not available for Mo(>1.5)
338 IS 16208 (2015) Textiles - High density polyethylene (HDPE)/polypropylene (PP) woven sacks for packaging 10 kg, 15 kg, 20 kg, 25 kg and 30 kg foodgrains - Specification all varieties. Rs.19750/- (including all parameters), Rs.10450/- (excl View breakup
-
- -
Complete.
339 IS 1061 (2025) Disinfectant Fluids, Phenolic Type - Specification ( Sixth Revision ) Class, Grade and Type to be declared - View breakup
22,151/- for Gr 1A,2A,3A and 16,151/- for Gr 1,2,3 for Disinfectant-cum-De-odorizing fluids and 16,551/- for Gr 1A,2A,3A and 10,551/- for Gr 1,2,3 for other classes
- -
Except cl 4.2.4 Description (Disinfectant-cum-De-odourizing Fluids), cl 4.8.1 Volatile Matter, cl 4.8.2 The material shall not be less than 40 percent (v/v) steam volatile oil when determined by the steam distillation, cl 4.8.3 Odour, cl 4.8.4 Persistance of Odour, cl 4.8.5 Flash Point (Abel), cl 4.6/4.2.4 Stability on storage [Description (Disinfectant-cum-De-odourizing Fluids)], cl 4.6/4.8.1 Stability on storage [Volatile Matter], cl 4.6/4.8.2 Stability on storage [The material shall not be less than 40 percent (v/v) steam volatile oil when determined by the steam distillation], cl 4.6/4.8.3 Stability on storage [Odour], cl 4.6/4.8.4 Stability on storage [Persistance of Odour], cl 4.6/4.8.5 Stability on storage [Flash Point (Abel)].
340 IS 10631 (1983) Specification for stainless steel for welding electrode core wire All - View breakup
-
- -
Size and designation to be declared.
341 IS 16353 (2015) Portland Cement Clinker - Specification - Rs. 5700/ View breakup
-
- -
Chem-Declaration for chloride regarding end use of cement (as per Table 1), Confirmation required for testing Alkali Content. Sample quantity- For physical tests 8 kg clinker ground with gypsum as per Cl 6.1, for chemical tests 2 kg clinker is to be provided.
342 IS 7098 : Part 1 (1988) Specification for crosslinked polyethylene insulated pvc sheathed cables: Part 1 for working voltages up to and including 1100 volts (First Revision) complete cat 01(except water absorption above 25sqmm) 26250 View breakup
-
- -
Elec-For cat.-01: Up to 240 sq mm all tests can be carried out (except water absorption). However, facility not available for Loss of mass above 1.2 mm thickness, Tensile & Elongation above 2.0 mm thickness and Water absorption test above 25 sq.mm cable. All facilities available for C1 & C2- except additional tests
343 IS 3074 (2013) Steel tubes for automotive purposes - Specification (Third Revision) All grades except for the tests mentioned in remarks 4200 View breakup
-
- -
Facility not available for leak tightness test. Grade designation, type, class, condition to be declared. Chem- Complete for CDS but Partial for ERW,CEW (facility not available for micro alloying elements)
344 IS 398 : Part 4 (1994) Aluminium conductors for overhead transmission purposes: Part 4 aluminium alloy stranded conductors (Aluminium - Magnesium - Silicon Type) - Specification (Third Revision) Complete facility available upto 100 sq mm only Please see remarks View breakup
For stranded conductors with 7 strands- Rs.1500 For stranded conductors with 19 strands- Rs.3600 For stranded conductors with 37 strands- Rs. 6750 For stranded conductors with 61 strands- Rs. 10650
- -
Elec-Complete facility available upto 100 sq mm only. For Above 100 sq.mm. facility not available for Stress-Strain Test, Surface Condition, Ultimate B/L on stranded conductor.
345 IS 1417 (2016) Gold and gold alloys, jewellery/ artefacts - Fineness and marking - Specification (Fourth Revision) 9K375, 14K585, 18K750, 20K833, 22K916, 23K958) and Gold Alloy/ Bullion (24KS995, 24KF999) Rs.1800.00 View breakup
-
- -
Yellow Gold Alloy Jewellery - (9K375, 14K585, 18K750, 20K833, 22K916, 23K958) and Gold Alloy/ Bullion (24KS995, 24KF999) Min sample quantity for 9K - 1.5 gram and for other grade as per guidelines.
346 IS 13428 (2005) Packaged natural mineral water specification (Second Revision) - 19200 View breakup
All except Radio Active Residues (RAR)- Rs 19200.00, All except Pesticide Residues (PRs) & RARs- Rs. 13900.00, All except Micro, PRs & RARs- Rs. 8750.00, Only Micro- Rs. 5900.00
- -
Excluding Cyanide, Radio Active Elements
347 IS 3812 (Part 1) (2013) Pulverized fuel ash - Specification: Part 1 For use as pozzolana in cement, cement mortar and concrete - Rs. 21850/- View breakup
-
- -
Type of Fuel ash to be declared, Declaration required regarding Moisture requirement
348 IS 2062 (2011) Hot rolled medium and high tensile structural steel - Specification (Seventh Revision) For all grades except for the tests mentioned in remarks 3200 View breakup
-
- -
Mech - NDT tests can be done with Ultrasonic Flaw detector only, specify method if otherwise; for impact test prepared pieces to be sent; Prepared test piece to be sent for Y groove crackability test. Chem- Type of Killed material to be declared, in case applicable.
349 IS 12818 (2010) Unplasticized polyvinyl chloride (Pvc - U) screen and casing pipes for bore/tubewells - Specification (Second Revision) All sizes/types Rs.6450.00 View breakup
-
- -
Chemical: All except Effect on Water which is for Pipes above 60 mm Nominal dia and except for the requirement of 'Other Toxic Substances such a di-n-octyl Tin -s-s bis iso-octyl mercapto acetate' and 'butyl stearate'; Mech- All except HST.
350 IS 4985 (2000) Unplasticized pvc pipes for potable water supplies - Specification (Third Revision) All sizes/varieties 4550 View breakup
-
- -
Chemical: All except Effect on Water which is for Pipes above 60 mm Nominal dia and except for the requirement of 'Other Toxic Substances such a di-n-octyl Tin -s-s bis iso-octyl mercapto acetate' and 'butyl stearate'; Mech- All except HST.
351 IS 398 : Part 2 (2025) Aluminium Conductor for Overhead Transmission Purposes - Specification Part 2 Aluminium Conductors Galvanized Steel Reinforced (Fourth Revision) - Please see remarks. View breakup
-
- -
"Partial: Up to 80 sq. mm-All Tests excluding Cl 13.15 Corona Test & Cl 13.16 Radio Interference Voltage Test. 100 sq mm and above-All tests excluding Cl 13.12 D.C Resistance test on stranded conductor, Cl 13.13 Surface Condition test, Cl 13.14 Ultimate Tensile Strength Test on Stranded conductor, Cl 13.15 Corona Test & Cl 13.16 Radio Interference Voltage Test."
352 IS 1786 (2008) High strength deformed steel bars and wires for concretere inforcement - Specification (Fourth Revision) For all grades except for the tests mentioned in remarks 25780 View breakup
-
- -
Mech - Facility not available for pull out test, total elongation at maximum force. Chem- Declarations to be provided regarding type of 'Killed' material/Micro-alloys/low-alloys/Nitrogen content or any other parameter to be analysed additionally
353 IS 1554 : Part 1 (1988) Specification for pvc insulated (Heavy Duty) electric cables: Part 1 for working voltages up to and including 1100 v (Third Revision) Complete for Cat 01(up to 400sq.mm)Except optional test Rs 26700 View breakup
-
- -
For Category-01 and upto 400 sq mm: all tests are available except additional tests. For cat. C1 and C2 : Except oxygen Index,Temperature index, Flame Retardance, Smoke Density,
354 IS 455 (2015) Portland slag cement - Specification - - View breakup
-
- -
Mech-Facility not available for transverse strength test( optional); Chem-Declaration for chloride regarding end use of cement required as per Table 1, Confirmation for testing Alkali Content required.
355 IS 4984 (2016) Polyethylene pipes for water supply - Specification (Fifth Revision) All varieties - View breakup
-
- -
Mech- Except Hydraulic test, Slow Crack Growth Rate and Internal Pressure Creep Rupture test. Fused pipes required to be provided for T/S of butt fusion joints. Prepared test pieces required for density. Chem- Complete
356 IS 1489 (Part 1) (2015) Portland pozzolana cement - Specification: Part 1 fly Ash Based - - View breakup
-
- -
Mech- Facility not available for transverse strength test( optional); Chem-Declaration for chloride regarding end use of cement (as per Table 1) and declaration of fly ash content & Confirmation for testing Alkali Content required.
357 IS 694 (2010) Polyvinyl chloride insulated unsheathed and sheathed cables/cords with rigid and flexible conductor for rated voltages up to and including 450/750 v (Fourth Revision) Complete for Category 01- up to & including 400 sq mm Please see remarks View breakup
-
- -
Chem- Facility available for Cu purity only,Gr to be declared. Elect- Cat -01, 02 (Facility not available for- Loss of mass above 1.2 mm, Tensile & Elongation above 2.0 mm thickness.) Cat- FR, FR-LSH-( Facility not available for- oxygen index, temp. index test, Smoke Density Tests). Chem- Facility available for Cu purity only,Grade/class to be declared