S.No. Indian Standard No. Product Grade / Type / Size / Designation etc. Testing Charges (Excl. Of Taxes) Validity Date Remark
361 IS 4985 (2000) Unplasticized pvc pipes for potable water supplies - Specification (Third Revision) All sizes/varieties 4550 View breakup
-
- -
Chemical: All except Effect on Water which is for Pipes above 60 mm Nominal dia and except for the requirement of 'Other Toxic Substances such a di-n-octyl Tin -s-s bis iso-octyl mercapto acetate' and 'butyl stearate'; Mech- All except HST.
362 IS 398 : Part 2 (2025) Aluminium Conductor for Overhead Transmission Purposes - Specification Part 2 Aluminium Conductors Galvanized Steel Reinforced (Fourth Revision) - Please see remarks. View breakup
-
- -
"Partial: Up to 80 sq. mm-All Tests excluding Cl 13.15 Corona Test & Cl 13.16 Radio Interference Voltage Test. 100 sq mm and above-All tests excluding Cl 13.12 D.C Resistance test on stranded conductor, Cl 13.13 Surface Condition test, Cl 13.14 Ultimate Tensile Strength Test on Stranded conductor, Cl 13.15 Corona Test & Cl 13.16 Radio Interference Voltage Test."
363 IS 1786 (2008) High strength deformed steel bars and wires for concretere inforcement - Specification (Fourth Revision) For all grades except for the tests mentioned in remarks 25780 View breakup
-
- -
Mech - Facility not available for pull out test, total elongation at maximum force. Chem- Declarations to be provided regarding type of 'Killed' material/Micro-alloys/low-alloys/Nitrogen content or any other parameter to be analysed additionally
364 IS 1554 : Part 1 (1988) Specification for pvc insulated (Heavy Duty) electric cables: Part 1 for working voltages up to and including 1100 v (Third Revision) Complete for Cat 01(up to 400sq.mm)Except optional test Rs 26700 View breakup
-
- -
For Category-01 and upto 400 sq mm: all tests are available except additional tests. For cat. C1 and C2 : Except oxygen Index,Temperature index, Flame Retardance, Smoke Density,
365 IS 455 (2015) Portland slag cement - Specification - - View breakup
-
- -
Mech-Facility not available for transverse strength test( optional); Chem-Declaration for chloride regarding end use of cement required as per Table 1, Confirmation for testing Alkali Content required.
366 IS 4984 (2016) Polyethylene pipes for water supply - Specification (Fifth Revision) All varieties - View breakup
-
- -
Mech- Except Hydraulic test, Slow Crack Growth Rate and Internal Pressure Creep Rupture test. Fused pipes required to be provided for T/S of butt fusion joints. Prepared test pieces required for density. Chem- Complete
367 IS 1489 (Part 1) (2015) Portland pozzolana cement - Specification: Part 1 fly Ash Based - - View breakup
-
- -
Mech- Facility not available for transverse strength test( optional); Chem-Declaration for chloride regarding end use of cement (as per Table 1) and declaration of fly ash content & Confirmation for testing Alkali Content required.
368 IS 694 (2010) Polyvinyl chloride insulated unsheathed and sheathed cables/cords with rigid and flexible conductor for rated voltages up to and including 450/750 v (Fourth Revision) Complete for Category 01- up to & including 400 sq mm Please see remarks View breakup
-
- -
Chem- Facility available for Cu purity only,Gr to be declared. Elect- Cat -01, 02 (Facility not available for- Loss of mass above 1.2 mm, Tensile & Elongation above 2.0 mm thickness.) Cat- FR, FR-LSH-( Facility not available for- oxygen index, temp. index test, Smoke Density Tests). Chem- Facility available for Cu purity only,Grade/class to be declared