BIS, Eastern Regional Laboratory (ERL)

(1) Annex Building & Sample-Cell: Bureau of Indian Standards, P-230, CIT Scheme, VII- M, Block-W,Kankurgachi,Kolkata-700054 (2) Main building: 1/14, CIT Scheme VII M, VIP Road, Kankurgachi,Kolkata-700054, Kolkata, Kolkata, West Bengal, 700054
- sample.erol@bis.gov.in
Scope List
Reset
370 Results
S.No. Indian Standard No. Product Grade / Type / Size / Designation etc. Testing Charges (Excl. Of Taxes) Validity Date Remark
361 IS 2062 (2011) Hot rolled medium and high tensile structural steel - Specification (Seventh Revision) For all grades except for the tests mentioned in remarks 3200 View breakup
-
- -
Mech - Facility not available for NDT tests ; for impact test prepared pieces to be sent; Prepared test piece to be sent for Y groove crackability test. Chem- Type of Killed material to be declared in case applicable.
362 IS 12818 (2010) Unplasticized polyvinyl chloride (Pvc - U) screen and casing pipes for bore/tubewells - Specification (Second Revision) All sizes/types Rs.6450.00 View breakup
-
- -
Chemical: All except Effect on Water which is for Pipes above 60 mm Nominal dia and except for the requirement of 'Other Toxic Substances such a di-n-octyl Tin -s-s bis iso-octyl mercapto acetate' and 'butyl stearate'; Mech- All except HST.
363 IS 4985 (2000) Unplasticized pvc pipes for potable water supplies - Specification (Third Revision) All sizes/varieties 4550 View breakup
-
- -
Chemical: All except Effect on Water which is for Pipes above 60 mm Nominal dia and except for the requirement of 'Other Toxic Substances such a di-n-octyl Tin -s-s bis iso-octyl mercapto acetate' and 'butyl stearate'; Mech- All except HST.
364 IS 398 : Part 2 (2025) Aluminium Conductor for Overhead Transmission Purposes - Specification Part 2 Aluminium Conductors Galvanized Steel Reinforced (Fourth Revision) - Please see remarks. View breakup
-
- -
"Partial: Up to 80 sq. mm-All Tests excluding Cl 13.15 Corona Test & Cl 13.16 Radio Interference Voltage Test. 100 sq mm and above-All tests excluding Cl 13.12 D.C Resistance test on stranded conductor, Cl 13.13 Surface Condition test, Cl 13.14 Ultimate Tensile Strength Test on Stranded conductor, Cl 13.15 Corona Test & Cl 13.16 Radio Interference Voltage Test."
365 IS 1786 (2008) High strength deformed steel bars and wires for concretere inforcement - Specification (Fourth Revision) For all grades except for the tests mentioned in remarks 25780 View breakup
-
- -
Mech - Facility not available for pull out test, total elongation at maximum force. Chem- Declarations to be provided regarding type of 'Killed' material/Micro-alloys/low-alloys/Nitrogen content or any other parameter to be analysed additionally
366 IS 1554 : Part 1 (1988) Specification for pvc insulated (Heavy Duty) electric cables: Part 1 for working voltages up to and including 1100 v (Third Revision) Complete for Cat 01(up to 400sq.mm)Except optional test Rs 26700 View breakup
-
- -
For Category-01 and upto 400 sq mm: all tests are available except additional tests. For cat. C1 and C2 : Except oxygen Index,Temperature index, Flame Retardance, Smoke Density,
367 IS 455 (2015) Portland slag cement - Specification - - View breakup
-
- -
Mech-Facility not available for transverse strength test( optional); Chem-Declaration for chloride regarding end use of cement required as per Table 1, Confirmation for testing Alkali Content required.
368 IS 4984 (2016) Polyethylene pipes for water supply - Specification (Fifth Revision) All varieties - View breakup
-
- -
Mech- Except Hydraulic test, Slow Crack Growth Rate and Internal Pressure Creep Rupture test. Fused pipes required to be provided for T/S of butt fusion joints. Prepared test pieces required for density. Chem- Complete
369 IS 1489 (Part 1) (2015) Portland pozzolana cement - Specification: Part 1 fly Ash Based - - View breakup
-
- -
Mech- Facility not available for transverse strength test( optional); Chem-Declaration for chloride regarding end use of cement (as per Table 1) and declaration of fly ash content & Confirmation for testing Alkali Content required.
370 IS 694 (2010) Polyvinyl chloride insulated unsheathed and sheathed cables/cords with rigid and flexible conductor for rated voltages up to and including 450/750 v (Fourth Revision) Complete for Category 01- up to & including 400 sq mm Please see remarks View breakup
Category: 01 Unsheathed cable: a) Single Core, Plain Copper Conductor - Rs.10500 b) Single Core, Tinned Copper Conductor- Rs.10800 c) Single Core, Solid Aluminium Conductor- Rs.10200 d) Single Core, Stranded Aluminium Conductor- Rs.10200 Sheathed Cable: a) Single Core, Plain Copper Conductor- Rs. 17550 b) Single Core, Tinned Copper Conductor - Rs.17850 c) Single Core, Solid Aluminium Conductor- Rs. 17250 d) Single Core, Stranded Aluminium Conductor- Rs.17250 Category: 02 Unsheathed cable: a) Single Core, Plain Copper Conductor- Rs.12150 b) Single Core, Tinned Copper Conductor- Rs.12450 c) Single Core, Solid Aluminium Conductor - Rs.11850 d) Single Core, Stranded Aluminium Conductor - Rs.11850 Sheathed Cable: a) Single Core, Plain Copper Conductor - Rs.18900 b) Single Core, Tinned Copper Conductor - Rs.19200 c) Single Core, Solid Aluminium Conductor - Rs.18600 d) Single Core, Stranded Aluminium Conductor - Rs.18600 Multi core cable: For each additional core, the charges of single core unsheathed cable as per material (copper and aluminium) and as per construction of conductor (solid or stranded, tinned or plain) shall be added
- -
Chem- Facility available for Cu purity only,Gr to be declared. Elect- Cat -01, 02 (Facility not available for- Loss of mass above 1.2 mm, Tensile & Elongation above 2.0 mm thickness.) Cat- FR, FR-LSH-( Facility not available for- oxygen index, temp. index test, Smoke Density Tests). Chem- Facility available for Cu purity only,Grade/class to be declared

Designed, Developed and Maintained by:

Arohatech IT Services (P) Ltd.

Contact for any query/support: supportlims@bis.gov.in