| 1 |
IS 13252 : Part 1 (2010) |
Information technology equipment - Safety: Part 1 general requirements (Second Revision) |
- |
60000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 1.6(Power interface .) |
- |
2000 |
|
- |
| 1.7(Markings and instructions) |
- |
1000 |
|
- |
| 2.1(Protection from electric shock and energy hazards) |
- |
1500 |
|
- |
| 2.2(SELV circuits) |
- |
1500 |
|
- |
| 2.3(TNV circuits) |
- |
1500 |
|
- |
| 2.4(Limited current circuits) |
- |
1500 |
|
- |
| 2.5(Limited power sources .) |
- |
1500 |
|
- |
| 2.6(Provisions for earthing and bonding) |
- |
1500 |
|
- |
| 2.7(Overcurrent and earth fault protection in primary circuits) |
- |
1500 |
|
- |
| 2.8(Safety interlocks) |
- |
1500 |
|
- |
| 2.9(Electrical insulation) |
- |
36000 |
|
300/Hour |
| 2.10(Clearances, creepage distances and distances through insulation) |
- |
1500 |
|
- |
| 3.1(General) |
- |
0 |
|
- |
| 3.2(Connection to a mains supply) |
- |
1500 |
|
- |
| 3.3(Wiring terminals for connection of external conductors) |
- |
0 |
|
- |
| 4.1(Stability) |
- |
1500 |
|
- |
| 4.2(Mechanical strength) |
- |
1500 |
|
- |
| 4.3(Design and construction) |
- |
1500 |
|
- |
| 4.4(Protection against hazardous moving parts) |
- |
1500 |
|
- |
| 1.5(Components) |
- |
0 |
|
- |
| 4.6(Openings in enclosures) |
- |
1500 |
|
- |
| 4.7(Resistance to fire) |
- |
1500 |
|
- |
| 5.2(Electric strength) |
- |
1500 |
|
- |
| 5.3(Abnormal operating and fault conditions) |
- |
4000 |
|
- |
| 6.1(Protection of telecommunication network service persons, and users of other equipment connected to the network, from hazards in the equipment) |
- |
0 |
|
- |
| 7.1(General) |
- |
0 |
|
- |
| Annex A3(Hot flaming oil test) |
- |
0 |
|
- |
| Annex B(Motor tests under abnormal conditions) |
- |
0 |
|
- |
| Annex C(Transformers) |
- |
0 |
|
- |
| Annex U(Insulating winding wires for use without interleaved insulation) |
- |
0 |
|
- |
| 4.5(Thermal requirements) |
- |
4000 |
|
- |
| 3.4(Disconnection from the mains supply) |
- |
1000 |
|
- |
| 3.5(Interconnection of equipment) |
- |
500 |
|
- |
| 5.1(Touch current and protective conductor curren) |
- |
2000 |
|
- |
| 6.2(Protection of equipment users from overvoltages on networks telecommunication) |
- |
2000 |
|
- |
| 6.3(Protection of the telecommunication wiring system from overheating) |
- |
2000 |
|
- |
| 7.2(Protection of cable distribution system service persons, and users of other equipment connected to the system, from hazardous voltages in the equipment) |
- |
2000 |
|
- |
| 7.3(Protection of equipment users from overvoltages on the cable distribution system) |
- |
2000 |
|
- |
| 7.4(Insulation between primary circuits and cable distribution systems) |
- |
1000 |
|
- |
| 1.5(Components) |
- |
0 |
|
- |
|
23 Dec, 2027 |
- - |
| 2 |
IS 616 (2017) |
Audio, video and similar electronic apparatus - Safety requirements (Fifth Revision) |
- |
60000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4(General test conditions) |
- |
0 |
|
- |
| 5(Marking and instructions) |
- |
2000 |
|
- |
| 7(Heating under normal operating conditions) |
- |
7000 |
|
- |
| 8(Constructional requirements with regard to the protection against electric shock) |
- |
3000 |
|
- |
| 9(Electric shock hazard under normal operating conditions) |
- |
3000 |
|
- |
| 10(Insulation requirements) |
- |
15000 |
|
- |
| 12(Mechanical strength) |
- |
10000 |
|
- |
| 13(CLEARANCES and CREEPAGE DISTANCES) |
- |
3000 |
|
- |
| 15(TERMINALS) |
- |
4000 |
|
- |
| 16(External flexible cords) |
- |
3000 |
|
- |
| 17(Electrical connections and mechanical fixings) |
- |
3000 |
|
- |
| 19(Stability and mechanical hazards) |
- |
3000 |
|
- |
| 20(Resistance to fire) |
- |
3000 |
|
- |
| Annex-A(Additional requirements for apparatus with protection against splashing water) |
- |
0 |
|
- |
| 11(Fault conditions) |
- |
2000 |
|
- |
| 14(Components) |
- |
0 |
|
- |
|
23 Dec, 2027 |
- - |
| 3 |
IS 302 : Part 2 : Sec 25 (2014) |
Safety of household and similar electrical appliances: Part 2 Particular requirements: Section 25 Microwave ovens |
- |
58500 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 7(Marking and instructions) |
- |
1500 |
|
- |
| 8(Protection against live parts) |
- |
1500 |
|
- |
| 10(POWER INPUT AND CURRENT) |
- |
1500 |
|
- |
| 11(HEATING) |
- |
10000 |
|
- |
| 13(LEAKAGE CURRENT AND ELECTRIC STRENGTH AT OPERATING TEMPERATURE) |
- |
1500 |
|
- |
| 14(IMPULSE VOLTAGE TEST) |
- |
1500 |
|
- |
| 15(HUMIDITY TREATMENT TEST) |
- |
14400 |
|
- |
| 16(LEAKAGE CURRENT AND ELECTRIC STRENGTH) |
- |
1500 |
|
- |
| 17(OVERLOAD PROTECTION OF TRANSFORMERS AND ASSOCIATED CIRCUITS) |
- |
1500 |
|
- |
| 18(ENDURANCE) |
- |
10000 |
|
- |
| 19(ABNORMAL OPERATION) |
- |
5000 |
|
- |
| 20(STABILITY AND MECHANICAL HAZARDS) |
- |
1000 |
|
Each |
| 22(CONSTRUCTION) |
- |
1500 |
|
- |
| 23(INTERNAL WIRING) |
- |
1500 |
|
- |
| 25(SUPPLY CONNECTION AND EXTERNAL FLEXIBLE CORDS) |
- |
1500 |
|
- |
| 26(TERMINALS FOR EXTERNAL CONDUCTORS) |
- |
1500 |
|
- |
| 27(PROVISION FOR EARTHING) |
- |
1500 |
|
- |
| 28(SCREWS AND CONNECTIONS) |
- |
1500 |
|
- |
| 29(CLEARANCES, CREEPAGE DISTANCES AND SOLID INSULATION) |
- |
1500 |
|
- |
| 30(RESISTANCE TO HEAT AND FIRE) |
- |
2000 |
|
Each |
| 31(RESISTANCE TO RUSTING) |
- |
1500 |
|
- |
| 32(RADIATION, TOXICITY AND SIMILAR HAZARDS) |
- |
3000 |
|
- |
| 6.0(Classification) |
- |
500 |
|
- |
| 9(STARTING OF MOTOR-OPERATED APPLIANCES) |
- |
500 |
|
- |
| 21(MECHANICAL STRENGTH) |
- |
2000 |
|
- |
| 24(COMPONENTS) |
- |
0 |
|
- |
|
23 Dec, 2027 |
- 24 (COMPONENTS)
(ABNORMAL OPERATION) |
| 4 |
IS 15885 : Part 2 : Sec 13 (2012) |
Safety of lamp controlgear: Part 2 particular requirements: Sec 13 d.c. or a.c. supplied electronic controlgear for led modules |
- |
50000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 7(Marking) |
- |
2000 |
|
- |
| 8(Protection against accidental contact with live parts) |
- |
3000 |
|
- |
| 10(PROVISION FOR EARTHING) |
- |
3000 |
|
- |
| 9(Terminals) |
- |
2000 |
|
- |
| 11(MOISTURE RESISTANCE) |
- |
300 |
|
Per Hour |
| 12(Electric Strength) |
- |
4000 |
|
- |
| 14(Fault conditions) |
- |
5000 |
|
- |
| 15(Transformer heating) |
- |
4000 |
|
- |
| 17(Creepage distance and clearances) |
- |
3000 |
|
- |
| 18(Screws, current carrying parts and connections) |
- |
1500 |
|
- |
| 19(Resistance to heat, fire and tracking) |
- |
2000 |
|
- |
| 20(Resistance to corrosion) |
- |
1500 |
|
- |
| 16(Construction) |
- |
0 |
|
- |
|
23 Dec, 2027 |
- - |
| 5 |
IS 10322 : Part 5 : Sec 2 (2012) |
Luminaires: Part 5 particular requirements: Sec 2 recessed luminaires (First Revision) |
- |
40000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6(Marking) |
- |
2000 |
|
- |
| 7(Construction) |
- |
2000 |
|
- |
| 8(Creepage Distance and Clearances) |
- |
3000 |
|
- |
| 9(Provision for earthing) |
- |
3000 |
|
- |
| 10(Terminals) |
- |
2000 |
|
- |
| 11(External & Internal Wiring) |
- |
3000 |
|
- |
| 12(Protection against electric shock) |
- |
2000 |
|
- |
| 13(Endurance Tests and Thermal Tests) |
- |
5000 |
|
- |
| 14(Resistance to Dust and Moisture) |
- |
300 |
|
Given Charges are per hour |
| 15(Insulation Resistance and Electric Strength) |
- |
4000 |
|
- |
| 16(Resistance to Heat , fire and tracking) |
- |
4000 |
|
- |
| 4(General Test Requireements) |
- |
0 |
|
- |
| 5(Classification of Luminaires') |
- |
0 |
|
- |
|
23 Dec, 2027 |
- - |
| 6 |
IS 10322 : Part 5 : Sec 1 (2012) |
Luminaires: Part 5 particular requirements: Sec 1 fixed general purpose luminaires (First Revision) |
- |
40000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6.0(Marking) |
- |
2000 |
|
- |
| 7.0(Construction) |
- |
2000 |
|
- |
| 8.0(Creepage Distance and Clearances) |
- |
3000 |
|
- |
| 9.0(Provision for earthing) |
- |
3000 |
|
- |
| 10.0(Terminals) |
- |
2000 |
|
- |
| 11.0(External & Internal Wiring) |
- |
3000 |
|
- |
| 12.0(Protection against electric shock) |
- |
2000 |
|
- |
| 13.0(Endurance Tests and Thermal Tests) |
- |
5000 |
|
- |
| 14.0(Resistance to Dust & Moisture) |
- |
300 |
|
Given Charges are per hour |
| 15.0(Insulation Resistance and Electric Strength) |
- |
4000 |
|
- |
| 16.0(Resistance to Heat , fire and tracking) |
- |
4000 |
|
- |
| 4(General Test Requireements) |
- |
0 |
|
- |
| 5(Classification of Luminaires') |
- |
0 |
|
- |
|
23 Dec, 2027 |
- - |
| 7 |
IS 302 : Part 1 (2008) |
Safety of household and similar electrical appliances: Part 1 general requirements (Sixth Revision) |
- |
60000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 7(Marking and instructions) |
- |
1500 |
|
- |
| 8.1.1(Protection against live parts in all positions) |
- |
1500 |
|
- |
| 8.1.2(Protection against live parts in openings) |
- |
1500 |
|
- |
| 8.1.3(Protection against live parts in visible glowing heating elements) |
- |
1500 |
|
- |
| 8.1.4(Protection against live parts against protective impedance) |
- |
1500 |
|
- |
| 10.1(Power input) |
- |
1500 |
|
- |
| 10.2(Current input) |
- |
1500 |
|
- |
| 11.1(General) |
- |
0 |
|
- |
| 11.2(General) |
- |
0 |
|
- |
| 11.3(Heating) |
- |
10000 |
|
- |
| 13.1(General) |
- |
0 |
|
- |
| 13.2(Leakage current at operating temperature) |
- |
1500 |
|
- |
| 14(Transient Over Voltages) |
- |
1500 |
|
- |
| 15.0(General) |
- |
0 |
|
- |
| 15.1(Ingress Protection test other than IPX0 (IP test)) |
- |
1500 |
|
- |
| 15.2(Spillage Test) |
- |
1500 |
|
- |
| 15.3(Humidity Test) |
- |
14400 |
|
- |
| 16.0(General) |
- |
0 |
|
- |
| 16.1(General) |
- |
0 |
|
- |
| 16.2(Leakage Current (after Clause 15)) |
- |
1500 |
|
- |
| 16.3(Electric Strength (after clause 15 and 16.2)) |
- |
1500 |
|
- |
| 17(Over Load Protection of Transformers and associated circuits) |
- |
1500 |
|
- |
| 19(Abnormal Operation) |
- |
3000 |
|
- |
| 20(Stability test) |
- |
1000 |
|
Each |
| 21(Mechanical Strength Test) |
- |
1500 |
|
- |
| 22(Construction verification related test) |
- |
1500 |
|
- |
| 23(General) |
- |
1500 |
|
- |
| 25(Supply connection and external flexible cords) |
- |
1500 |
|
- |
| 26(Terminals for external conductors) |
- |
1500 |
|
- |
| 27(Provision for earthing) |
- |
1500 |
|
- |
| 28(Screw test and connections) |
- |
1500 |
|
- |
| 29(clearance, creepage distances and solid insulation) |
- |
1500 |
|
- |
| 30.1(Ball pressure test) |
- |
1000 |
|
- |
| 30.2(Needle Flame Test) |
- |
1000 |
|
- |
| 31(Resistance to Rusting) |
- |
1500 |
|
- |
| 8.1.5(Live parts of built-in appliances) |
- |
0 |
|
- |
| 11.4(Heating appliances) |
- |
0 |
|
- |
| 11.5(Motor-operated appliances) |
- |
0 |
|
- |
| 11.6(Combined appliances) |
- |
0 |
|
- |
| 11.7(Duration corresponding) |
- |
0 |
|
- |
| 11.8(Temperature rise) |
- |
0 |
|
- |
| 19.11.4.1(Electrostatic discharges) |
- |
3000 |
|
- |
| 19.11.4.3(Fast transient bursts) |
- |
3000 |
|
- |
| 19.11.4.4(Surge immunity test) |
- |
3000 |
|
- |
| 9(Starting of motor operation test requirements and tests) |
- |
1000 |
|
- |
| 13.3(Electric Strength at operating temperature) |
- |
1500 |
|
- |
| 24(Components) |
- |
0 |
|
- |
|
23 Dec, 2027 |
- 24 (Components)
19.11.4.2 (Radiated fields) |
| 8 |
IS 16102 : Part 1 (2012) |
Self - Ballasted led lamps for general lighting services: Part 1 safety requirements |
- |
40000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 5(Marking) |
- |
2000 |
|
- |
| 6(Interchangeability) |
- |
5000 |
|
- |
| 7(Protection against accidental contact with live parts) |
- |
3000 |
|
- |
| 8(Insulation Resistance and Electric Strength) |
- |
4000 |
|
- |
| 9(MECHANICAL STRENGTH) |
- |
4000 |
|
- |
| 10(cap temperature) |
- |
5000 |
|
- |
| 11(Resistance to Heat) |
- |
3000 |
|
- |
| 12(Resistance to Flame and Ignition) |
- |
3000 |
|
- |
| 13(Fault conditions) |
- |
3000 |
|
- |
| 14(Creepage distance and clearances) |
- |
2000 |
|
- |
|
23 Dec, 2027 |
- - |
| 9 |
IS 16333 : Part 3 (2017) |
Mobile phone handsets: Part 3 indian language support for mobile phone handsets - Specific requirements (First Revision) |
- |
20000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 5.1(Inputting of text) |
- |
15000 |
|
- |
| 5.2(Message Readability) |
- |
15000 |
|
- |
|
23 Dec, 2027 |
- - |
| 10 |
IS 16270 (2023) |
Secondary cells and batteries for solar photovoltaic application - General requirements and methods of test |
- |
1950000 View breakup
For Ni-Cd/Ni-MH/Li-System up to 250 Ah Rs.1350000/
For vented type cell / Battery Rs. 1300000/
For Lead acid cell/ Battery Rs.1950000/
(Range >250Ah to 400Ah)
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl-4.1(Photovoltaic Energy System) |
- |
5000 |
|
- |
| Cl-4.2(Secondary Cells and Batteries) |
- |
5000 |
|
- |
| Cl-4.3(General Operating Conditions) |
- |
5000 |
|
- |
| Cl-4.3.8(Storage) |
- |
5000 |
|
- |
| Cl-5.1(Mechanical Endurance) |
- |
5000 |
|
- |
| Cl-5.2(Charge Efficiency) |
- |
5000 |
|
- |
| Cl-5.3(Deep Discharge Protection) |
- |
5000 |
|
- |
| Cl-5.4(Marking) |
- |
5000 |
|
- |
| Cl-5.5(Safety) |
- |
5000 |
|
- |
| Cl-5.6(Documentation) |
- |
5000 |
|
- |
| Cl-6(Functional characteristice) |
- |
5000 |
|
- |
| Cl-7(General test conditions) |
- |
5000 |
|
- |
| Cl-8.1(Capacity Test) |
- |
20000 |
|
- |
| Cl-8.2(Endurance Test) |
- |
800000 |
|
- |
| Cl-8.3(Charge Retention Test) |
- |
30000 |
|
- |
| Cl-8.4(Cycle Endurance in Photovoltaic Application (Extreme Conditions)) |
- |
1500000 |
|
- |
| Cl-8.5(Sulphation Test (Applicable for Lead Acid Batteries only)) |
- |
25000 |
|
- |
| Cl-8.6(Water Loss Test (Valid for Flooded Lead Acid Batteries only)) |
- |
40000 |
|
- |
| 4.3.7.1(Specific gravity) |
- |
5000 |
|
- |
| Cl-9.1(Type Tests) |
- |
5000 |
|
- |
| Cl-9.2(Acceptance Test) |
- |
5000 |
|
- |
| Cl-4.3.9(Operating Temperature) |
- |
5000 |
|
- |
|
23 Dec, 2027 |
- Included.w.e.f.04.12.2024 |
| 11 |
IS 16046 : Part 2 (2018) |
Secondary Cells and Batteries Containing Alkaline or Other Non-Acid Electrolytes ” Safety Requirements for Portable Sealed Secondary Cells and for Batteries Made from Them for Use in Portable Applications Part 2 Lithium Systems ( Second Revision ) |
- |
480000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4(Parameter Measurement Tolerances) |
- |
5000 |
|
- |
| 5(General Safety Considerations) |
- |
5000 |
|
- |
| 5.1(General) |
- |
5000 |
|
- |
| 5.2(Insulation and Wiring) |
- |
10000 |
|
- |
| 5.3(Venting) |
- |
5000 |
|
- |
| 5.4(Temperature, Voltage and Current Management) |
- |
5000 |
|
- |
| 5.5(Terminal Contacts) |
- |
5000 |
|
- |
| 5.6(Assembly of Cells into batteries) |
- |
5000 |
|
- |
| 5.7(Quality Plan) |
- |
5000 |
|
- |
| 5.8(Battery Safety Components) |
- |
5000 |
|
- |
| 6(Type Test and Sample Size) |
- |
5000 |
|
- |
| 7(Specific requirements and tests) |
- |
5000 |
|
- |
| 7.1(Charging procedure for test purposes) |
- |
20000 |
|
- |
| 7.2(Intended Use) |
- |
30000 |
|
- |
| 7.3(Reasonably foreseeable misuse) |
- |
330000 |
|
- |
| 8(Information for safety) |
- |
5000 |
|
- |
| 8.1(General) |
- |
5000 |
|
- |
| 8.2(Small Cell and battery safety information) |
- |
5000 |
|
- |
| 9(Marking) |
- |
5000 |
|
- |
| 9.1(Cell Marking) |
- |
5000 |
|
- |
| 9.2(Battery Marking) |
- |
5000 |
|
- |
| 9.3(Caution for ingestion of small cells and batteries) |
- |
5000 |
|
- |
| 9.4(Other information) |
- |
1000 |
|
- |
| 10(Packaging) |
- |
5000 |
|
- |
| 4(Parameter Measurement Tolerances) |
- |
5000 |
|
- |
| 5(General Safety Considerations) |
- |
5000 |
|
- |
| 5.1(General) |
- |
5000 |
|
- |
| 5.2(Insulation and Wiring) |
- |
10000 |
|
- |
| 5.3(Venting) |
- |
5000 |
|
- |
| 5.4(Temperature, Voltage and Current Management) |
- |
5000 |
|
- |
| 5.5(Terminal Contacts) |
- |
5000 |
|
- |
| 5.6(Assembly of Cells into batteries) |
- |
5000 |
|
- |
| 5.7(Quality Plan) |
- |
5000 |
|
- |
| 5.8(Battery Safety Components) |
- |
5000 |
|
- |
| 6(Type Test and Sample Size) |
- |
5000 |
|
- |
| 7(Specific requirements and tests) |
- |
5000 |
|
- |
| 7.1(Charging procedure for test purposes) |
- |
20000 |
|
- |
| 7.2(Intended Use) |
- |
30000 |
|
- |
| 7.3(Reasonably foreseeable misuse) |
- |
330000 |
|
- |
| 8(Information for safety) |
- |
5000 |
|
- |
| 8.1(General) |
- |
5000 |
|
- |
| 8.2(Small Cell and battery safety information) |
- |
5000 |
|
- |
| 9(Marking) |
- |
5000 |
|
- |
| 9.1(Cell Marking) |
- |
5000 |
|
- |
| 9.2(Battery Marking) |
- |
5000 |
|
- |
| 9.3(Caution for ingestion of small cells and batteries) |
- |
5000 |
|
- |
| 9.4(Other information) |
- |
1000 |
|
- |
| 10(Packaging) |
- |
5000 |
|
- |
|
23 Dec, 2027 |
- Included w.e.f.04.2024 |
| 12 |
IS 16046 : Part 1 (2018) |
Secondary Cells and Batteries Containing Alkaline or Other Non-Acid Electrolytes ” Safety Requirements for Portable Sealed Secondary Cells and for Batteries Made from Them for Use in Portable Applications Part 1 Nickel Systems ( Second Revision ) |
- |
340000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4(Parameter Measurement Tolerances) |
- |
0 |
|
- |
| 5(General Safety Considerations) |
- |
0 |
|
- |
| 5.1(General) |
- |
0 |
|
- |
| 5.2(Insulation and Wiring) |
- |
10000 |
|
- |
| 5.3(Venting) |
- |
5000 |
|
- |
| 5.4(Temperature, Voltage and Current Management) |
- |
5000 |
|
- |
| 5.5(Terminal Contacts) |
- |
5000 |
|
- |
| 5.6(Assembly of Cells into batteries) |
- |
5000 |
|
- |
| 5.7(Quality Plan) |
- |
5000 |
|
- |
| 6(Tyoe Test amd Sample Size) |
- |
5000 |
|
- |
| 7(Specific requirements and tests) |
- |
0 |
|
- |
| 7.1(Charging procedure for test purposes) |
- |
20000 |
|
- |
| 7.2(Intended Use) |
- |
100000 |
|
- |
| 7.3(Reasonably foreseeable misuse) |
- |
150000 |
|
- |
| 8(Information for safety) |
- |
5000 |
|
- |
| 8.1(General) |
- |
5000 |
|
- |
| 8.2(Small Cell and battery safety information) |
- |
10000 |
|
- |
| 9(Marking) |
- |
5000 |
|
- |
| 9.1(Cell Marking) |
- |
5000 |
|
- |
| 9.2(Battery Marking) |
- |
10000 |
|
- |
| 9.3(Caution for ingestion of small cells and batteries) |
- |
10000 |
|
- |
| 9.4(Other information) |
- |
5000 |
|
- |
| 10(Packaging) |
- |
5000 |
|
- |
|
23 Dec, 2027 |
- Included w.e.f.04.12.2024 |