1 |
IS 9968 : Part 2 (2002) |
Specification for elastomer - Insulated cables: Part 2 for working voltages from 3.3 kV up to and including 33 kV (First Revision) |
- |
-
|
195000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
4.1(CONDUCTORS: Cables for Fixed Installation) |
- |
500 |
|
- |
4.2(CONDUCTORS:Flexible Cables) |
- |
500 |
|
- |
5(INSULATION) |
- |
500 |
|
- |
6(SEMICONDUCTING COMPOUND) |
- |
500 |
|
- |
7.1(Proofed Tape) |
- |
500 |
|
- |
7.2(Polyethylene Terephthalate ( P E T P ) or
Polypropylene Base Tape : Thickness) |
- |
500 |
|
- |
7.3(Tape ) |
- |
500 |
|
- |
8(SCREENING) |
- |
500 |
|
- |
9(CENTRE AND FILLERS) |
- |
500 |
|
- |
10(ARMOUR) |
- |
500 |
|
- |
11.1(Inner Sheath) |
- |
500 |
|
- |
11.2(Outer Sheath) |
- |
500 |
|
- |
12.1(Tapes) |
- |
500 |
|
- |
12.2(Cords and Yarns) |
- |
500 |
|
- |
13.1 & 13.2(CONSTRUCTION:CONDUCTORS-Cables for Fixed Installations/Flexible Cables) |
- |
500 |
|
- |
13.3(Earthing Conductor) |
- |
500 |
|
- |
13.3.1(Earthing Conductor) |
- |
500 |
|
- |
13.4(Separator Tape) |
- |
500 |
|
- |
14(CONDUCTOR SCREENING) |
- |
500 |
|
- |
15.1(INSULATION : Application) |
- |
500 |
|
- |
15.2(Thickness of Insulation) |
- |
1000 |
|
- |
15.3(Tolerance on Thickness of Insulation) |
- |
1000 |
|
- |
16.1(INSULATION SCREENING : Application) |
- |
500 |
|
- |
16.2(INSULATION SCREENING : Parts ) |
- |
500 |
|
- |
16.3(INSULATION SCREENING : Non Metallic Parts ) |
- |
500 |
|
- |
16.4(INSULATION SCREENING : Metallic Parts ) |
- |
500 |
|
- |
17(CORE IDENTIFICATION) |
- |
500 |
|
- |
17(CORE IDENTIFICATION: Unscreed cable ) |
- |
500 |
|
- |
18.1(LAYING UP OF CORES) |
- |
500 |
|
- |
18.2(LAYING UP OF CORES : Flexible cable) |
- |
500 |
|
- |
18.3(LAYING UP OF CORES : Binder Tape) |
- |
500 |
|
- |
19.1(Inner Sheath : Application) |
- |
500 |
|
- |
19.2(Thickness of Inner Sheath) |
- |
1000 |
|
- |
19.3(Inner Sheath : proofed tape) |
- |
500 |
|
- |
20.1(ARMOURING: Application) |
- |
500 |
|
- |
20.2(Type of Armour) |
- |
500 |
|
- |
20.2 1.2(Direction of lay of armour) |
- |
500 |
|
- |
20.2 1.3(Joint in armour) |
- |
500 |
|
- |
20.2.2(Filling Factot ) |
- |
500 |
|
- |
20.2.2(Diameter of braiding) |
- |
500 |
|
- |
20.2.2.1(Braiding material) |
- |
500 |
|
- |
20.3(Substitution of the galvanized steel wires/formed) |
- |
500 |
|
- |
21.1(OUTER SHEATH) |
- |
500 |
|
- |
21.2(Coulor of Outer sheath) |
- |
500 |
|
- |
21.3(Thickness of Outer Sheat: Average) |
- |
1000 |
|
- |
21.3(Thickness of Outer Sheat: Minimum) |
- |
1000 |
|
- |
22.1 a)1)(Annealing test
(for copper) - IS 10810: Part 1) |
- |
1500 |
|
- |
22.1 a)2)(Tensile test
(for aluminium) -IS 10810: Part 2) |
- |
1500 |
|
- |
22.1 a)3)(Wrapping Test
(for aluminium) - IS 10810: Part 3) |
- |
1500 |
|
- |
22.1 a)4)(Conductor resistance
test) |
- |
5000 |
|
- |
22.1 a)5)(Persulphate test
(tinned copper
conductor)- IS 10810: Part 4) |
- |
5000 |
|
- |
22.1 b)1)(Test for Galvanized Steel
Wires/Formed Wires
1) Dimensions -IS 10810: Part 36) |
- |
1000 |
|
- |
22.1 b)2)i)(Test for Galvanized Steel
Wires/Formed Wires
2) Tensile Strentgh -IS 10810: Part 37) |
- |
1500 |
|
- |
22.1 b)2)ii)(Test for Galvanized Steel
Wires/Formed Wires
2) Elongation at break -IS 10810: Part 37) |
- |
1500 |
|
- |
22.1 b)2)iii)(Test for Galvanized Steel
Wires/Formed Wires
3) Torsion (for round
wires only) -IS 10810: Part 38) |
- |
1500 |
|
- |
22.1 b)2)iv)(Test for Galvanized Steel
Wires/Formed Wires
4) Winding (for strips
only) -IS 10810: Part 39) |
- |
1500 |
|
- |
22.1 b)2)v)(Test for Galvanized Steel
Wires/Formed Wires
5) Zinc coating : Uniformity-IS 10810: Part 40) |
- |
1500 |
|
- |
22.1 b)2)vi)(Test for Galvanized Steel
Wires/Formed Wires
5) Zinc coating : Mass -IS 10810: Part 41) |
- |
1500 |
|
- |
22.1 b)2) vii) (Resistivity - IS 10810: Part 42) |
- |
5000 |
|
- |
22.1 c)2)(Physical Tests for
Insulation : Tensile Strenth - IS 10810: Part 7) |
- |
2500 |
|
- |
22.1 c)2)(Physical Tests for
Insulation : Elongation - IS 10810: Part 7) |
- |
2500 |
|
- |
22.1 c)2)(Physical Tests for
Sheath : Tensile Strenth - IS 10810: Part 7) |
- |
2500 |
|
- |
22.1 c)2)(Physical Tests for
Sheath : Elongation - IS 10810: Part 7) |
- |
2500 |
|
- |
22.1 c)3)(Physical Tests for
Insulation ( Ageing in air oven): Tensile Strenth - IS 10810: Part 11) |
- |
5000 |
|
- |
22.1 c)3)(Physical Tests for
Insulation ( Ageing in air oven): Tensile Strenth Variation - IS 10810: Part 12) |
- |
5000 |
|
- |
22.1 c)3)(Physical Tests for
Insulation( Ageing in air oven) : Elongation - IS 10810: Part 11) |
- |
5000 |
|
- |
22.1 c)3)(Physical Tests for
Insulation( Ageing in air oven) : Elongation variation - IS 10810: Part 12) |
- |
5000 |
|
- |
22.1 c)3)(Physical Tests for
Sheath( Ageing in air oven) : Tensile Strenth - IS 10810: Part 11) |
- |
5000 |
|
- |
22.1 c)3)(Physical Tests for
Sheath( Ageing in air oven) : Tensile Strenth variation - IS 10810: Part 12) |
- |
5000 |
|
- |
22.1 c)3)(Physical Tests for
Sheath ( Ageing in air oven): Elongation - IS 10810: Part 11) |
- |
5000 |
|
- |
22.1 c)3)(Physical Tests for
Sheath ( Ageing in air oven): Elongation variation - IS 10810: Part 12) |
- |
5000 |
|
- |
22.1 c)4)(Physical Tests for
Insulation ( Ageing in air bomb): Tensile Strenth variation - IS 10810: Part 56) |
- |
5000 |
|
- |
22.1 c)4)(Physical Tests for
Insulation( Ageing in air bomb) : Elongation variation - IS 10810: Part 56) |
- |
5000 |
|
- |
22.1 c)4)(Physical Tests for
Sheath(Ageing in air bomb) : Tensile Strenth variation - IS 10810: Part 56) |
- |
5000 |
|
- |
22.1 c)4)(Physical Tests for
Sheath ( Ageing in air bomb): Elongation variation - IS 10810: Part 56) |
- |
5000 |
|
- |
22.1 c)5)(Physical Tests for
Insulation :Hot set Elongation - IS 10810: Part 30) |
- |
2500 |
|
- |
22.1 c)5)(Physical Tests for
Insulation :Permanent set - IS 10810: Part 30) |
- |
2500 |
|
- |
22.1 c)5)(Physical Tests for
Sheath :Hot set Elongation - IS 10810: Part 30) |
- |
2500 |
|
- |
22.1 c)5)(Physical Tests for
Sheath :Permanent set - IS 10810: Part 30) |
- |
2500 |
|
- |
22.1 c)6)(Physical Tests for
Sheath(Oil resistance test) : Tensile Strenth Variation - IS 10810: Part 31) |
- |
5000 |
|
- |
22.1 c)6)(Physical Tests for
Sheath ( Oil resistance test): Elongation Variation - IS 10810: Part 31) |
- |
5000 |
|
- |
22.1 c)7)(Tear Resistance test - IS 10810: Part 17) |
- |
2500 |
|
- |
22.1 c)8)(Shrinkage : Insulation - IS 10810: Part 12) |
- |
5000 |
|
- |
22.1 c)8)(Shrinkage test- Crack observed : Insulation - IS 10810: Part 13) |
- |
5000 |
|
- |
22.1 c)8)(Shrinkage test : Sheath - IS 10810: Part 12) |
- |
2500 |
|
- |
22.1 c)8)(Shrinkage test - Crack oberved : Sheath - IS 10810: Part 13) |
- |
2500 |
|
- |
22.1 c)9)(Hot deformation test : Insulation - IS 10810: Part 15) |
- |
5000 |
|
- |
22.1 c)9)(Hot deformation test : Sheath - IS 10810: Part 15) |
- |
5000 |
|
- |
22.1 c)10)(Loss of mass in air
oven : Insulation - IS 10810: Part 10) |
- |
5000 |
|
- |
22.1 c)10)(Loss of mass in air
oven : Sheath - IS 10810: Part 10) |
- |
5000 |
|
- |
22.1 c)11)(Heat shock : Insulation - IS 10810: Part 14) |
- |
2500 |
|
- |
22.1 c)11)(Heat shock : Sheath - IS 10810: Part 14) |
- |
2500 |
|
- |
22.1 c)12)(Thermal stability : Insulation - IS 10810: Part 60) |
- |
1500 |
|
- |
22.1 c)12)(Thermal stability : Sheath - IS 10810: Part 60) |
- |
1500 |
|
- |
22.1 d)(Insulation Resistance Test: Volume resistivity ) |
- |
7000 |
|
- |
22.1 d)(Insulation Resistance Test: Insulation resistance constant ) |
- |
5000 |
|
- |
22.1 e)(Partial Discharge Test) |
- |
45000 |
|
- |
22.1 f)(Bending Test Followed by
Partial Discharge Test) |
- |
5000 |
|
- |
22.1 g)(Dielectric Power Factor
Test
1) As a function of Voltage) |
- |
25000 |
|
- |
22.1 g)(Dielectric Power Factor
Test
1) As a function of
temperature) |
- |
30000 |
|
- |
22.1 h)(Heating Cycle Test) |
- |
30000 |
|
- |
22.1 j)(Impulse Withstand Test) |
- |
35000 |
|
- |
22.1 k)(High Voltage Test
for Four Hours) |
- |
10000 |
|
- |
22.1 m)(Water Absorption Test - IS 10810: Part 28) |
- |
7000 |
|
- |
22.1 n)(Flammability) |
- |
2500 |
|
- |
24.1(Manufacturer's Identification) |
- |
500 |
|
- |
24.2(Voltage Identification) |
- |
500 |
|
- |
24.3(Cable Code) |
- |
500 |
|
- |
25.2.1(Marking on drum ) |
- |
500 |
|
- |
25.2.2(BIS Certification Marking) |
- |
500 |
|
- |
22.4 (a)(Ozone Resistance Test) |
- |
5000 |
|
- |
22.4 (b)(Cold impacts test for PVC sheath) |
- |
2500 |
|
- |
7.1(Proofed Tape: Thickness) |
- |
1000 |
|
- |
|
Complete
|
|
16 Apr, 2026 |
- Included w.e.f.17.03.2025 |
2 |
IS 14494 (2019) |
Elastomer insulated flexible cables for use in mines - Specification (First Revision) |
- |
-
|
210000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
4(CONDUCTOR) |
- |
500 |
|
- |
5(INSULATION) |
- |
500 |
|
- |
5.1(Power Cores) |
- |
500 |
|
- |
5.2(Pilot and Earth Cores) |
- |
500 |
|
- |
6(SEMI-CONDUCTING COMPOUND) |
- |
500 |
|
- |
7.1(TAPE : Proofed Tape) |
- |
500 |
|
- |
7.2(TAPE : Polyethylene Terephalate (PETP) or
Polypropylene Base Tape) |
- |
500 |
|
- |
8(CENTRE) |
- |
500 |
|
- |
9.1(FILLERS) |
- |
500 |
|
- |
9.2(FILLERS) |
- |
500 |
|
- |
10(CRADLE SEPARATOR) |
- |
500 |
|
- |
11.1(ARMOUR) |
- |
500 |
|
- |
11.2(ARMOUR) |
- |
500 |
|
- |
11.2 a)(ARMOURING: Tensile Strength) |
- |
1500 |
|
- |
11.2 b)(ARMOURING: Elongation ) |
- |
1500 |
|
- |
11.2 c)(ARMOURING: Torsion Test (For round wire ) ) |
- |
1500 |
|
- |
11.2 d)(ARMOURING: Uniformity of zinc coating) |
- |
1500 |
|
- |
11.2 e)(ARMOURING: Mass of zinc coating ) |
- |
1500 |
|
- |
12.1(SHEATH : Inner Sheath) |
- |
500 |
|
- |
12.2(SHEATH : Outer Sheath) |
- |
500 |
|
- |
13.1(REINFORCEMENT MATERIAL : Tape) |
- |
500 |
|
- |
13.2(REINFORCEMENT MATERIAL : Cord/Yarns) |
- |
500 |
|
- |
14.1(CONSTRUCTION : CONDUCTOR) |
- |
500 |
|
- |
14.2(CONSTRUCTION : CONDUCTOR) |
- |
500 |
|
- |
14.3(CONSTRUCTION : CONDUCTOR) |
- |
500 |
|
- |
14.4(CONSTRUCTION : CONDUCTOR) |
- |
500 |
|
- |
15(CONDUCTOR SCREENING) |
- |
500 |
|
- |
16.1(INSULATION) |
- |
500 |
|
- |
16.2(INSULATION : Thickness of Insulation) |
- |
1000 |
|
- |
16.3(INSULATION : Tolerance on Insulation Thickness) |
- |
1000 |
|
- |
16.4(INSULATION : Application of Insulation) |
- |
500 |
|
- |
16.5(INSULATION) |
- |
500 |
|
- |
17.1(INSULATION SCREEN) |
- |
500 |
|
- |
17.2(INSULATION SCREEN) |
- |
500 |
|
- |
17.3(INSULATION SCREEN) |
- |
500 |
|
- |
18(PROTECTIVE SCREEN) |
- |
500 |
|
- |
19(CONDUCTANCE OF SCREEN) |
- |
500 |
|
- |
19.1(Individual Core Screen) |
- |
500 |
|
- |
19.2(Collective Screen) |
- |
500 |
|
- |
20.1(CORE IDENTIFICATION) |
- |
500 |
|
- |
20.2(Colour Scheme for Identification) |
- |
500 |
|
- |
20.3(Scheme for Identification by Numbering) |
- |
500 |
|
- |
21.1(LAYING UP OF CORES) |
- |
500 |
|
- |
21.2(LAYING UP OF CORES) |
- |
500 |
|
- |
21.3(LAYING UP OF CORES) |
- |
500 |
|
- |
21.4(LAYING UP OF CORES) |
- |
500 |
|
- |
22.1(INNER SHEATH) |
- |
500 |
|
- |
22.2(Thickness of Inner Sheath) |
- |
1000 |
|
- |
22.3(INNER SHEATH) |
- |
500 |
|
- |
23.1(ARMOURING) |
- |
1500 |
|
- |
23.2(ARMOURING) |
- |
1500 |
|
- |
23.3(ARMOURING) |
- |
1500 |
|
- |
23.4(ARMOURING) |
- |
1500 |
|
- |
24.1(OUTER SHEATH) |
- |
500 |
|
- |
24.2(Thickness of Outer Sheath) |
- |
1000 |
|
- |
25.1(CABLE CONSTRUCTION AND DIMENSIONS) |
- |
500 |
|
- |
27.2(Bending test followed by partial discharge test;) |
- |
15000 |
|
- |
27.4(Dielectric power factor test) |
- |
25000 |
|
- |
27.5(Heating cycle test followed by partial discharge test;) |
- |
30000 |
|
- |
27.6(Impulse voltage test; and) |
- |
35000 |
|
- |
26.3(Special Provisions) |
- |
500 |
|
- |
27.8(Flammability Test) |
- |
2500 |
|
- |
27.9(Water Absorption Test) |
- |
7000 |
|
- |
29.1(PACKING AND MARKING) |
- |
500 |
|
- |
29.2(PACKING AND MARKING) |
- |
500 |
|
- |
30(BIS CERTIFICATION MARKING) |
- |
500 |
|
- |
Table 33®, Annex E(Electric tset on semi-conducting screen) |
- |
2500 |
|
- |
Table 33(n), Cl. No. 27.7(High Voltage test for 4 hrs.) |
- |
10000 |
|
- |
Table 33(j), Cl. No. 27.4(Dielectric Power Factor (as a function of Voltage)) |
- |
30000 |
|
- |
Table 33(h), Cl. No. 27.2(Partial discharge test) |
- |
45000 |
|
- |
Table 33(f)(Insulation resistance) |
- |
7000 |
|
- |
Table 33(e)(Tear resistance on sheath) |
- |
2500 |
|
- |
Table 33(e)(Oil resistance - Elongation on sheath) |
- |
5000 |
|
- |
Table 33(e)(Oil resistance - Tensile strength on sheath) |
- |
5000 |
|
- |
Table 33(e)(Permanent set on Sheath) |
- |
2500 |
|
- |
Table 33(e)(Hot set on Sheath) |
- |
2500 |
|
- |
Table 33(e)(Ageing in air bomb - Elongation on Sheath) |
- |
5000 |
|
- |
Table 33(e)(Ageing in air bomb - Tensile strength on Sheath) |
- |
5000 |
|
- |
Table 33(e)(Elongation at break on Sheath) |
- |
2500 |
|
- |
Table 33(e)(Tensile strength on Sheath) |
- |
2500 |
|
- |
Table 33(d)(Ozone resistance on Insulation) |
- |
15000 |
|
- |
Table 33(d)(Permanent set on Insulation) |
- |
2500 |
|
- |
Table 33(d)(Hot set on Insulation) |
- |
2500 |
|
- |
Table 33(d)(Ageing in air bomb - Elongation on Insulation) |
- |
5000 |
|
- |
Table 33(d)(Ageing in air bomb - Tensile strength on Insulation) |
- |
5000 |
|
- |
Table 33(d)(Ageing in air oven - Elongation on Insulation) |
- |
5000 |
|
- |
Table 33(d)(Ageing in air oven - Tensile strength on Insulation) |
- |
5000 |
|
- |
Table 33(d)(Elongation at break on Insulation) |
- |
2500 |
|
- |
Table 33(d)(Tensile strength on Insulation) |
- |
2500 |
|
- |
Table 33(c)(Resistivity of steel wire) |
- |
1500 |
|
- |
Table 33(b)(Diameter of armour wire) |
- |
500 |
|
- |
Table 4(Copper purity test) |
- |
5000 |
|
- |
Table 33(a)(Conductor resistance test) |
- |
5000 |
|
- |
Table 33(a)(Annealing test) |
- |
1500 |
|
- |
[ Cl.12.2 & Table 3 IS:6380-1984](Physical tests on Outer Sheath ( Without ageing)) |
- |
2500 |
|
- |
[ Cl.12.2 & Table 3 IS:6380-1984](Physical tests on Outer Sheath ( Without ageing)) |
- |
2500 |
|
- |
[ Cl.12.2 & Table 3 IS:6380-1984](Physical tests on Outer Sheath ( Without ageing)) |
- |
2500 |
|
- |
[ Cl.12.2 & Table 3 IS:6380-1984](Physical tests on Outer Sheath ( After ageing in air bomb) |
- |
5000 |
|
- |
[ Cl.12.2 & Table 3 IS:6380-1984](Physical tests on Outer Sheath ( After ageing in air bomb) |
- |
5000 |
|
- |
[ Cl.12.2 & Table 3 IS:6380-1984](Physical tests on Outer Sheath (Oil resistance test )) |
- |
5000 |
|
- |
[ Cl.12.2 & Table 3 IS:6380-1984](Physical tests on Outer Sheath) |
- |
2500 |
|
- |
[ Cl.12.2 & Table 3 IS:6380-1984](Physical tests on Outer Sheath (Hot set test)) |
- |
2500 |
|
- |
[ Cl.12.2 & Table 3 IS:6380-1984](Physical tests on Outer Sheath (Hot set test)) |
- |
2500 |
|
- |
[ Cl.12.2 & Table 3 IS:6380-1984](Physical tests on Outer Sheath (Hot set test)) |
- |
2500 |
|
- |
[ Table 2 of IS:6380-1984](Insulation resistance constant) |
- |
5000 |
|
- |
[ Table 2 of IS:6380-1984](Insulation resistance constant) |
- |
5000 |
|
- |
[ Cl.5 & Table 2 of IS:6380-1984](Physical tests on Outer Sheath ( Without ageing)) |
- |
2500 |
|
- |
[ Cl.5 & Table 2 of IS:6380-1984](Physical tests on Outer Sheath ( Without ageing)) |
- |
2500 |
|
- |
[ Cl.5 & Table 2 of IS:6380-1984](Physical tests on insulation (After ageing in air oven:)) |
- |
5000 |
|
- |
[ Cl.5 & Table 2 of IS:6380-1984](Physical tests on insulation (After ageing in air oven:)) |
- |
5000 |
|
- |
[ Cl.5 & Table 2 of IS:6380-1984](Physical tests on insulation (After ageing in air bomb )) |
- |
5000 |
|
- |
[ Cl.5 & Table 2 of IS:6380-1984](Physical tests on insulation (After ageing in air bomb )) |
- |
5000 |
|
- |
[ Cl.5 & Table 2 of IS:6380-1984](Physical tests on Insulation (Hot set test)) |
- |
2500 |
|
- |
[ Cl.5 & Table 2 of IS:6380-1984](Physical tests on Insulation (Hot set test)) |
- |
2500 |
|
- |
[ Cl.4 & 14](Conductor) |
- |
500 |
|
- |
[ Cl.4 & 14](Conductor) |
- |
500 |
|
- |
[ Cl.4 & 14](Conductor) |
- |
500 |
|
- |
[ Cl.4 & 14](Conductor) |
- |
500 |
|
- |
[ Cl.4 & 14](Conductor) |
- |
500 |
|
- |
[ Cl.4 & 14](Conductor) |
- |
500 |
|
- |
[ Cl.4 & 14](Conductor) |
- |
500 |
|
- |
[Cl.14.4](Conductor) |
- |
500 |
|
- |
Cl. 27.7(High voltage test for 4 hours) |
- |
10000 |
|
- |
7.3(TAPE ) |
- |
500 |
|
- |
17.4(INSULATION SCREEN) |
- |
500 |
|
- |
24.3(Tolerance on Thickness of Outer Sheath) |
- |
1500 |
|
- |
24.4(OUTER SHEATH) |
- |
500 |
|
- |
28(IDENTIFICATION) |
- |
500 |
|
- |
|
Complete
|
|
16 Apr, 2026 |
- Included w.e.f.17.03.2025 |
3 |
IS 1554 : Part 2 (1988) |
Specification for pvc insulated (Heavy Duty) electric cables: Part 2 for working voltages from 3.3 kV up to and including 11 kV (Second Revision) |
- |
-
|
175000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
3.1(CONDUCTOR) |
- |
200 |
|
For BIS Samples – 1.5 times the BIS testing charges. For others : Rs. 1,75,000/- for type test of single core cable. Rs. 2,10,000/- for type test of three core cable Rs. 8500/- for additional test for C1(FR) Rs. 12500/- for additional test for C2(FR-LSH) |
3.1.1(CONDUCTOR) |
- |
200 |
|
For BIS Samples – 1.5 times the BIS testing charges. For others : Rs. 1,75,000/- for type test of single core cable. Rs. 2,10,000/- for type test of three core cable Rs. 8500/- for additional test for C1(FR) Rs. 12500/- for additional test for C2(FR-LSH) |
4.1(INSULATION) |
- |
200 |
|
For BIS Samples – 1.5 times the BIS testing charges. For others : Rs. 1,75,000/- for type test of single core cable. Rs. 2,10,000/- for type test of three core cable Rs. 8500/- for additional test for C1(FR) Rs. 12500/- for additional test for C2(FR-LSH) |
5.1(SCREENING) |
- |
200 |
|
For BIS Samples – 1.5 times the BIS testing charges. For others : Rs. 1,75,000/- for type test of single core cable. Rs. 2,10,000/- for type test of three core cable Rs. 8500/- for additional test for C1(FR) Rs. 12500/- for additional test for C2(FR-LSH) |
5.1.1(Non-magnetic Metallic Tape for SingleCore Unscreened and Unarmoured Cables) |
- |
200 |
|
For BIS Samples – 1.5 times the BIS testing charges. For others : Rs. 1,75,000/- for type test of single core cable. Rs. 2,10,000/- for type test of three core cable Rs. 8500/- for additional test for C1(FR) Rs. 12500/- for additional test for C2(FR-LSH) |
6.1(FILLERS AND INNER SHEATH) |
- |
200 |
|
For BIS Samples – 1.5 times the BIS testing charges. For others : Rs. 1,75,000/- for type test of single core cable. Rs. 2,10,000/- for type test of three core cable Rs. 8500/- for additional test for C1(FR) Rs. 12500/- for additional test for C2(FR-LSH) |
6.2(FILLERS AND INNER SHEATH) |
- |
200 |
|
For BIS Samples – 1.5 times the BIS testing charges. For others : Rs. 1,75,000/- for type test of single core cable. Rs. 2,10,000/- for type test of three core cable Rs. 8500/- for additional test for C1(FR) Rs. 12500/- for additional test for C2(FR-LSH) |
7.1(ARMOURING) |
- |
200 |
|
For BIS Samples – 1.5 times the BIS testing charges. For others : Rs. 1,75,000/- for type test of single core cable. Rs. 2,10,000/- for type test of three core cable Rs. 8500/- for additional test for C1(FR) Rs. 12500/- for additional test for C2(FR-LSH) |
7.2(ARMOURING) |
- |
200 |
|
For BIS Samples – 1.5 times the BIS testing charges. For others : Rs. 1,75,000/- for type test of single core cable. Rs. 2,10,000/- for type test of three core cable Rs. 8500/- for additional test for C1(FR) Rs. 12500/- for additional test for C2(FR-LSH) |
8.1(OUTER SHEATH) |
- |
2000 |
|
For BIS Samples – 1.5 times the BIS testing charges. For others : Rs. 1,75,000/- for type test of single core cable. Rs. 2,10,000/- for type test of three core cable Rs. 8500/- for additional test for C1(FR) Rs. 12500/- for additional test for C2(FR-LSH) |
9.1(CONDUCTOR) |
- |
200 |
|
For BIS Samples – 1.5 times the BIS testing charges. For others : Rs. 1,75,000/- for type test of single core cable. Rs. 2,10,000/- for type test of three core cable Rs. 8500/- for additional test for C1(FR) Rs. 12500/- for additional test for C2(FR-LSH) |
9.2(CONDUCTOR) |
- |
200 |
|
For BIS Samples – 1.5 times the BIS testing charges. For others : Rs. 1,75,000/- for type test of single core cable. Rs. 2,10,000/- for type test of three core cable Rs. 8500/- for additional test for C1(FR) Rs. 12500/- for additional test for C2(FR-LSH) |
10.1(CONDUCTOR SCREENING) |
- |
200 |
|
For BIS Samples – 1.5 times the BIS testing charges. For others : Rs. 1,75,000/- for type test of single core cable. Rs. 2,10,000/- for type test of three core cable Rs. 8500/- for additional test for C1(FR) Rs. 12500/- for additional test for C2(FR-LSH) |
11.1(INSULATION) |
- |
200 |
|
For BIS Samples – 1.5 times the BIS testing charges. For others : Rs. 1,75,000/- for type test of single core cable. Rs. 2,10,000/- for type test of three core cable Rs. 8500/- for additional test for C1(FR) Rs. 12500/- for additional test for C2(FR-LSH) |
11.2(INSULATION : Thickness of Insulation) |
- |
1000 |
|
For BIS Samples – 1.5 times the BIS testing charges. For others : Rs. 1,75,000/- for type test of single core cable. Rs. 2,10,000/- for type test of three core cable Rs. 8500/- for additional test for C1(FR) Rs. 12500/- for additional test for C2(FR-LSH) |
11.3(INSULATION : Tolerance on Thickness of Insulation) |
- |
1000 |
|
For BIS Samples – 1.5 times the BIS testing charges. For others : Rs. 1,75,000/- for type test of single core cable. Rs. 2,10,000/- for type test of three core cable Rs. 8500/- for additional test for C1(FR) Rs. 12500/- for additional test for C2(FR-LSH) |
11.4(INSULATION : Application of Insulation) |
- |
200 |
|
For BIS Samples – 1.5 times the BIS testing charges. For others : Rs. 1,75,000/- for type test of single core cable. Rs. 2,10,000/- for type test of three core cable Rs. 8500/- for additional test for C1(FR) Rs. 12500/- for additional test for C2(FR-LSH) |
12.1(INSULATION SCREENING) |
- |
200 |
|
For BIS Samples – 1.5 times the BIS testing charges. For others : Rs. 1,75,000/- for type test of single core cable. Rs. 2,10,000/- for type test of three core cable Rs. 8500/- for additional test for C1(FR) Rs. 12500/- for additional test for C2(FR-LSH) |
12.2(INSULATION SCREENING) |
- |
200 |
|
For BIS Samples – 1.5 times the BIS testing charges. For others : Rs. 1,75,000/- for type test of single core cable. Rs. 2,10,000/- for type test of three core cable Rs. 8500/- for additional test for C1(FR) Rs. 12500/- for additional test for C2(FR-LSH) |
12.3(INSULATION SCREENING) |
- |
200 |
|
For BIS Samples – 1.5 times the BIS testing charges. For others : Rs. 1,75,000/- for type test of single core cable. Rs. 2,10,000/- for type test of three core cable Rs. 8500/- for additional test for C1(FR) Rs. 12500/- for additional test for C2(FR-LSH) |
12.4(INSULATION SCREENING) |
- |
200 |
|
For BIS Samples – 1.5 times the BIS testing charges. For others : Rs. 1,75,000/- for type test of single core cable. Rs. 2,10,000/- for type test of three core cable Rs. 8500/- for additional test for C1(FR) Rs. 12500/- for additional test for C2(FR-LSH) |
13.1(CORE IDENTIFICATION) |
- |
200 |
|
For BIS Samples – 1.5 times the BIS testing charges. For others : Rs. 1,75,000/- for type test of single core cable. Rs. 2,10,000/- for type test of three core cable Rs. 8500/- for additional test for C1(FR) Rs. 12500/- for additional test for C2(FR-LSH) |
13.1.1(CORE IDENTIFICATION) |
- |
200 |
|
For BIS Samples – 1.5 times the BIS testing charges. For others : Rs. 1,75,000/- for type test of single core cable. Rs. 2,10,000/- for type test of three core cable Rs. 8500/- for additional test for C1(FR) Rs. 12500/- for additional test for C2(FR-LSH) |
14.1(LAYING UP OF CORES) |
- |
200 |
|
For BIS Samples – 1.5 times the BIS testing charges. For others : Rs. 1,75,000/- for type test of single core cable. Rs. 2,10,000/- for type test of three core cable Rs. 8500/- for additional test for C1(FR) Rs. 12500/- for additional test for C2(FR-LSH) |
15.1(INNER SHEATH (COMMON COVERING)) |
- |
200 |
|
For BIS Samples – 1.5 times the BIS testing charges. For others : Rs. 1,75,000/- for type test of single core cable. Rs. 2,10,000/- for type test of three core cable Rs. 8500/- for additional test for C1(FR) Rs. 12500/- for additional test for C2(FR-LSH) |
15.2(INNER SHEATH (COMMON COVERING)) |
- |
200 |
|
For BIS Samples – 1.5 times the BIS testing charges. For others : Rs. 1,75,000/- for type test of single core cable. Rs. 2,10,000/- for type test of three core cable Rs. 8500/- for additional test for C1(FR) Rs. 12500/- for additional test for C2(FR-LSH) |
15.3(INNER SHEATH (COMMON COVERING)) |
- |
200 |
|
For BIS Samples – 1.5 times the BIS testing charges. For others : Rs. 1,75,000/- for type test of single core cable. Rs. 2,10,000/- for type test of three core cable Rs. 8500/- for additional test for C1(FR) Rs. 12500/- for additional test for C2(FR-LSH) |
15.4(INNER SHEATH (COMMON COVERING) : Thickness of Inner Sheath) |
- |
1000 |
|
For BIS Samples – 1.5 times the BIS testing charges. For others : Rs. 1,75,000/- for type test of single core cable. Rs. 2,10,000/- for type test of three core cable Rs. 8500/- for additional test for C1(FR) Rs. 12500/- for additional test for C2(FR-LSH) |
15.4.1(INNER SHEATH (COMMON COVERING) : Thickness of Inner Sheath) |
- |
1000 |
|
For BIS Samples – 1.5 times the BIS testing charges. For others : Rs. 1,75,000/- for type test of single core cable. Rs. 2,10,000/- for type test of three core cable Rs. 8500/- for additional test for C1(FR) Rs. 12500/- for additional test for C2(FR-LSH) |
16.1.1(ARMOURING : Application) |
- |
200 |
|
For BIS Samples – 1.5 times the BIS testing charges. For others : Rs. 1,75,000/- for type test of single core cable. Rs. 2,10,000/- for type test of three core cable Rs. 8500/- for additional test for C1(FR) Rs. 12500/- for additional test for C2(FR-LSH) |
16.1.2(ARMOURING : Application) |
- |
200 |
|
For BIS Samples – 1.5 times the BIS testing charges. For others : Rs. 1,75,000/- for type test of single core cable. Rs. 2,10,000/- for type test of three core cable Rs. 8500/- for additional test for C1(FR) Rs. 12500/- for additional test for C2(FR-LSH) |
16.1.3(ARMOURING : Direction of lay ) |
- |
500 |
|
For BIS Samples – 1.5 times the BIS testing charges. For others : Rs. 1,75,000/- for type test of single core cable. Rs. 2,10,000/- for type test of three core cable Rs. 8500/- for additional test for C1(FR) Rs. 12500/- for additional test for C2(FR-LSH) |
16.1.4(ARMOURING : Application) |
- |
200 |
|
For BIS Samples – 1.5 times the BIS testing charges. For others : Rs. 1,75,000/- for type test of single core cable. Rs. 2,10,000/- for type test of three core cable Rs. 8500/- for additional test for C1(FR) Rs. 12500/- for additional test for C2(FR-LSH) |
16.2.1(ARMOURING : Type of Armour) |
- |
200 |
|
For BIS Samples – 1.5 times the BIS testing charges. For others : Rs. 1,75,000/- for type test of single core cable. Rs. 2,10,000/- for type test of three core cable Rs. 8500/- for additional test for C1(FR) Rs. 12500/- for additional test for C2(FR-LSH) |
16.2.2(ARMOURING : Type of Armour) |
- |
200 |
|
For BIS Samples – 1.5 times the BIS testing charges. For others : Rs. 1,75,000/- for type test of single core cable. Rs. 2,10,000/- for type test of three core cable Rs. 8500/- for additional test for C1(FR) Rs. 12500/- for additional test for C2(FR-LSH) |
16.3(Armouring : Dimensions -Wire Diameter) |
- |
1000 |
|
For BIS Samples – 1.5 times the BIS testing charges. For others : Rs. 1,75,000/- for type test of single core cable. Rs. 2,10,000/- for type test of three core cable Rs. 8500/- for additional test for C1(FR) Rs. 12500/- for additional test for C2(FR-LSH) |
16.3(Armouring : Dimensions -Formed wire ) |
- |
500 |
|
For BIS Samples – 1.5 times the BIS testing charges. For others : Rs. 1,75,000/- for type test of single core cable. Rs. 2,10,000/- for type test of three core cable Rs. 8500/- for additional test for C1(FR) Rs. 12500/- for additional test for C2(FR-LSH) |
16.4(ARMOURING : Joints) |
- |
200 |
|
For BIS Samples – 1.5 times the BIS testing charges. For others : Rs. 1,75,000/- for type test of single core cable. Rs. 2,10,000/- for type test of three core cable Rs. 8500/- for additional test for C1(FR) Rs. 12500/- for additional test for C2(FR-LSH) |
16.5(ARMOURING : Resistance) |
- |
1500 |
|
For BIS Samples – 1.5 times the BIS testing charges. For others : Rs. 1,75,000/- for type test of single core cable. Rs. 2,10,000/- for type test of three core cable Rs. 8500/- for additional test for C1(FR) Rs. 12500/- for additional test for C2(FR-LSH) |
13.6 a)(ARMOURING: Tensile Strength) |
- |
1500 |
|
For BIS Samples – 1.5 times the BIS testing charges. For others : Rs. 1,75,000/- for type test of single core cable. Rs. 2,10,000/- for type test of three core cable Rs. 8500/- for additional test for C1(FR) Rs. 12500/- for additional test for C2(FR-LSH) |
13.6 b)(ARMOURING: Elongation ) |
- |
1500 |
|
For BIS Samples – 1.5 times the BIS testing charges. For others : Rs. 1,75,000/- for type test of single core cable. Rs. 2,10,000/- for type test of three core cable Rs. 8500/- for additional test for C1(FR) Rs. 12500/- for additional test for C2(FR-LSH) |
13.6 c)(ARMOURING: Torsion Test (For round wire ) ) |
- |
1500 |
|
For BIS Samples – 1.5 times the BIS testing charges. For others : Rs. 1,75,000/- for type test of single core cable. Rs. 2,10,000/- for type test of three core cable Rs. 8500/- for additional test for C1(FR) Rs. 12500/- for additional test for C2(FR-LSH) |
13.6 d)(ARMOURING: Winding Test(For formed wire)) |
- |
1500 |
|
For BIS Samples – 1.5 times the BIS testing charges. For others : Rs. 1,75,000/- for type test of single core cable. Rs. 2,10,000/- for type test of three core cable Rs. 8500/- for additional test for C1(FR) Rs. 12500/- for additional test for C2(FR-LSH) |
13.6 e)(ARMOURING: Uniformity of zinc coating) |
- |
1500 |
|
For BIS Samples – 1.5 times the BIS testing charges. For others : Rs. 1,75,000/- for type test of single core cable. Rs. 2,10,000/- for type test of three core cable Rs. 8500/- for additional test for C1(FR) Rs. 12500/- for additional test for C2(FR-LSH) |
13.6 f)(ARMOURING: Mass of zinc coating ) |
- |
1000 |
|
For BIS Samples – 1.5 times the BIS testing charges. For others : Rs. 1,75,000/- for type test of single core cable. Rs. 2,10,000/- for type test of three core cable Rs. 8500/- for additional test for C1(FR) Rs. 12500/- for additional test for C2(FR-LSH) |
13.6 g)(ARMOURING: Resistivity) |
- |
2000 |
|
For BIS Samples – 1.5 times the BIS testing charges. For others : Rs. 1,75,000/- for type test of single core cable. Rs. 2,10,000/- for type test of three core cable Rs. 8500/- for additional test for C1(FR) Rs. 12500/- for additional test for C2(FR-LSH) |
17.1(OUTER SHEATH) |
- |
200 |
|
For BIS Samples – 1.5 times the BIS testing charges. For others : Rs. 1,75,000/- for type test of single core cable. Rs. 2,10,000/- for type test of three core cable Rs. 8500/- for additional test for C1(FR) Rs. 12500/- for additional test for C2(FR-LSH) |
17.2(OUTER SHEATH : colour ) |
- |
200 |
|
For BIS Samples – 1.5 times the BIS testing charges. For others : Rs. 1,75,000/- for type test of single core cable. Rs. 2,10,000/- for type test of three core cable Rs. 8500/- for additional test for C1(FR) Rs. 12500/- for additional test for C2(FR-LSH) |
17.3.1(Thickness of Outer Sheath : Unarmoured Cables) |
- |
1000 |
|
For BIS Samples – 1.5 times the BIS testing charges. For others : Rs. 1,75,000/- for type test of single core cable. Rs. 2,10,000/- for type test of three core cable Rs. 8500/- for additional test for C1(FR) Rs. 12500/- for additional test for C2(FR-LSH) |
17.3.2(Thickness of Outer Sheath : Armoured Cables) |
- |
1000 |
|
For BIS Samples – 1.5 times the BIS testing charges. For others : Rs. 1,75,000/- for type test of single core cable. Rs. 2,10,000/- for type test of three core cable Rs. 8500/- for additional test for C1(FR) Rs. 12500/- for additional test for C2(FR-LSH) |
18.1 a) 1)(Tests on Conductor : Annealing test (for copper)) |
- |
1000 |
|
For BIS Samples – 1.5 times the BIS testing charges. For others : Rs. 1,75,000/- for type test of single core cable. Rs. 2,10,000/- for type test of three core cable Rs. 8500/- for additional test for C1(FR) Rs. 12500/- for additional test for C2(FR-LSH) |
18.1 a) 2)(Tensile test (for aluminium) - Before stranding ) |
- |
1000 |
|
For BIS Samples – 1.5 times the BIS testing charges. For others : Rs. 1,75,000/- for type test of single core cable. Rs. 2,10,000/- for type test of three core cable Rs. 8500/- for additional test for C1(FR) Rs. 12500/- for additional test for C2(FR-LSH) |
18.1 a) 2)(Tensile test (for aluminium) - After stranding ) |
- |
1000 |
|
For BIS Samples – 1.5 times the BIS testing charges. For others : Rs. 1,75,000/- for type test of single core cable. Rs. 2,10,000/- for type test of three core cable Rs. 8500/- for additional test for C1(FR) Rs. 12500/- for additional test for C2(FR-LSH) |
18.1 a) 3)(Tests on Conductor : Wrapping test ( for aluminium)) |
- |
1000 |
|
For BIS Samples – 1.5 times the BIS testing charges. For others : Rs. 1,75,000/- for type test of single core cable. Rs. 2,10,000/- for type test of three core cable Rs. 8500/- for additional test for C1(FR) Rs. 12500/- for additional test for C2(FR-LSH) |
18.1 a)4)(Tests on conductor : Conductor resistance test - Main conductor ) |
- |
5000 |
|
For BIS Samples – 1.5 times the BIS testing charges. For others : Rs. 1,75,000/- for type test of single core cable. Rs. 2,10,000/- for type test of three core cable Rs. 8500/- for additional test for C1(FR) Rs. 12500/- for additional test for C2(FR-LSH) |
18.1 a)4)(Resistance test - Neutral conductor ) |
- |
5000 |
|
For BIS Samples – 1.5 times the BIS testing charges. For others : Rs. 1,75,000/- for type test of single core cable. Rs. 2,10,000/- for type test of three core cable Rs. 8500/- for additional test for C1(FR) Rs. 12500/- for additional test for C2(FR-LSH) |
18.1 d) 1)(Phyaical tests for insulation : Tensile Test) |
- |
2000 |
|
For BIS Samples – 1.5 times the BIS testing charges. For others : Rs. 1,75,000/- for type test of single core cable. Rs. 2,10,000/- for type test of three core cable Rs. 8500/- for additional test for C1(FR) Rs. 12500/- for additional test for C2(FR-LSH) |
18.1 d) 1)(Phyaical tests for insulation : Elongation ) |
- |
2000 |
|
For BIS Samples – 1.5 times the BIS testing charges. For others : Rs. 1,75,000/- for type test of single core cable. Rs. 2,10,000/- for type test of three core cable Rs. 8500/- for additional test for C1(FR) Rs. 12500/- for additional test for C2(FR-LSH) |
18.1 d) 1)(Physical tests for sheath : Tensile stregth ) |
- |
2000 |
|
For BIS Samples – 1.5 times the BIS testing charges. For others : Rs. 1,75,000/- for type test of single core cable. Rs. 2,10,000/- for type test of three core cable Rs. 8500/- for additional test for C1(FR) Rs. 12500/- for additional test for C2(FR-LSH) |
18.1 d) 1)(Physical tests for sheath : Elongation ) |
- |
2000 |
|
For BIS Samples – 1.5 times the BIS testing charges. For others : Rs. 1,75,000/- for type test of single core cable. Rs. 2,10,000/- for type test of three core cable Rs. 8500/- for additional test for C1(FR) Rs. 12500/- for additional test for C2(FR-LSH) |
18.1 d) 2)(Phyaical tests for insulation- Ageing in air Oven : Tensile Test) |
- |
5000 |
|
For BIS Samples – 1.5 times the BIS testing charges. For others : Rs. 1,75,000/- for type test of single core cable. Rs. 2,10,000/- for type test of three core cable Rs. 8500/- for additional test for C1(FR) Rs. 12500/- for additional test for C2(FR-LSH) |
18.1 d) 2)(Phyaical tests for insulation - Ageing in air oven : Elongation ) |
- |
5000 |
|
For BIS Samples – 1.5 times the BIS testing charges. For others : Rs. 1,75,000/- for type test of single core cable. Rs. 2,10,000/- for type test of three core cable Rs. 8500/- for additional test for C1(FR) Rs. 12500/- for additional test for C2(FR-LSH) |
18.1 d) 2)(Phyaical tests for insulation - Ageing in air Oven : Tensile Variation ) |
- |
5000 |
|
For BIS Samples – 1.5 times the BIS testing charges. For others : Rs. 1,75,000/- for type test of single core cable. Rs. 2,10,000/- for type test of three core cable Rs. 8500/- for additional test for C1(FR) Rs. 12500/- for additional test for C2(FR-LSH) |
18.1 d) 2)(Phyaical tests for insulation- Ageing in air oven : Elongation Variation ) |
- |
5000 |
|
For BIS Samples – 1.5 times the BIS testing charges. For others : Rs. 1,75,000/- for type test of single core cable. Rs. 2,10,000/- for type test of three core cable Rs. 8500/- for additional test for C1(FR) Rs. 12500/- for additional test for C2(FR-LSH) |
18.1 d) 2)(Physical tests for outer sheath- Ageing in air oven : Tensile stregth ) |
- |
5000 |
|
For BIS Samples – 1.5 times the BIS testing charges. For others : Rs. 1,75,000/- for type test of single core cable. Rs. 2,10,000/- for type test of three core cable Rs. 8500/- for additional test for C1(FR) Rs. 12500/- for additional test for C2(FR-LSH) |
18.1 d) 2)(Physical tests for outer sheath -Ageing in air oven : Elongation ) |
- |
5000 |
|
For BIS Samples – 1.5 times the BIS testing charges. For others : Rs. 1,75,000/- for type test of single core cable. Rs. 2,10,000/- for type test of three core cable Rs. 8500/- for additional test for C1(FR) Rs. 12500/- for additional test for C2(FR-LSH) |
18.1 d) 2)(Physical tests for outer sheath- Ageing in air oven : Tensile stregth Variation ) |
- |
5000 |
|
For BIS Samples – 1.5 times the BIS testing charges. For others : Rs. 1,75,000/- for type test of single core cable. Rs. 2,10,000/- for type test of three core cable Rs. 8500/- for additional test for C1(FR) Rs. 12500/- for additional test for C2(FR-LSH) |
18.1 d) 2)(Physical tests for outer sheath -Ageing in air oven : Elongation Variation ) |
- |
5000 |
|
For BIS Samples – 1.5 times the BIS testing charges. For others : Rs. 1,75,000/- for type test of single core cable. Rs. 2,10,000/- for type test of three core cable Rs. 8500/- for additional test for C1(FR) Rs. 12500/- for additional test for C2(FR-LSH) |
18.1 d) 3)(Phyaical tests for insulation : Shrinkage ) |
- |
1500 |
|
For BIS Samples – 1.5 times the BIS testing charges. For others : Rs. 1,75,000/- for type test of single core cable. Rs. 2,10,000/- for type test of three core cable Rs. 8500/- for additional test for C1(FR) Rs. 12500/- for additional test for C2(FR-LSH) |
18.1 d) 3)(Phyaical tests for insulation : Shrinkage - Crack observed ) |
- |
1500 |
|
For BIS Samples – 1.5 times the BIS testing charges. For others : Rs. 1,75,000/- for type test of single core cable. Rs. 2,10,000/- for type test of three core cable Rs. 8500/- for additional test for C1(FR) Rs. 12500/- for additional test for C2(FR-LSH) |
18.1 d) 3)(Phyaical tests for Sheath : Shrinkage ) |
- |
1500 |
|
For BIS Samples – 1.5 times the BIS testing charges. For others : Rs. 1,75,000/- for type test of single core cable. Rs. 2,10,000/- for type test of three core cable Rs. 8500/- for additional test for C1(FR) Rs. 12500/- for additional test for C2(FR-LSH) |
18.1 d) 3)(Phyaical tests for Sheath : Shrinkage - Crack observed ) |
- |
1500 |
|
For BIS Samples – 1.5 times the BIS testing charges. For others : Rs. 1,75,000/- for type test of single core cable. Rs. 2,10,000/- for type test of three core cable Rs. 8500/- for additional test for C1(FR) Rs. 12500/- for additional test for C2(FR-LSH) |
18.1 d) 4)(Hot deformation : Insulation ) |
- |
5000 |
|
For BIS Samples – 1.5 times the BIS testing charges. For others : Rs. 1,75,000/- for type test of single core cable. Rs. 2,10,000/- for type test of three core cable Rs. 8500/- for additional test for C1(FR) Rs. 12500/- for additional test for C2(FR-LSH) |
18.1 d) 4)(Hot deformation : Sheath ) |
- |
5000 |
|
For BIS Samples – 1.5 times the BIS testing charges. For others : Rs. 1,75,000/- for type test of single core cable. Rs. 2,10,000/- for type test of three core cable Rs. 8500/- for additional test for C1(FR) Rs. 12500/- for additional test for C2(FR-LSH) |
18.1 d) 5)( Loss of mass in air oven- Insulation ) |
- |
5000 |
|
For BIS Samples – 1.5 times the BIS testing charges. For others : Rs. 1,75,000/- for type test of single core cable. Rs. 2,10,000/- for type test of three core cable Rs. 8500/- for additional test for C1(FR) Rs. 12500/- for additional test for C2(FR-LSH) |
18.1 d) 5)( Loss of mass in air oven- sheath ) |
- |
5000 |
|
For BIS Samples – 1.5 times the BIS testing charges. For others : Rs. 1,75,000/- for type test of single core cable. Rs. 2,10,000/- for type test of three core cable Rs. 8500/- for additional test for C1(FR) Rs. 12500/- for additional test for C2(FR-LSH) |
18.1 d) 6)(Heat shock test- Insulation ) |
- |
1500 |
|
For BIS Samples – 1.5 times the BIS testing charges. For others : Rs. 1,75,000/- for type test of single core cable. Rs. 2,10,000/- for type test of three core cable Rs. 8500/- for additional test for C1(FR) Rs. 12500/- for additional test for C2(FR-LSH) |
18.1 d) 6)(Heat shock test- sheath ) |
- |
1500 |
|
For BIS Samples – 1.5 times the BIS testing charges. For others : Rs. 1,75,000/- for type test of single core cable. Rs. 2,10,000/- for type test of three core cable Rs. 8500/- for additional test for C1(FR) Rs. 12500/- for additional test for C2(FR-LSH) |
18.1 d) 7)(Thermal stability- insulation ) |
- |
2500 |
|
For BIS Samples – 1.5 times the BIS testing charges. For others : Rs. 1,75,000/- for type test of single core cable. Rs. 2,10,000/- for type test of three core cable Rs. 8500/- for additional test for C1(FR) Rs. 12500/- for additional test for C2(FR-LSH) |
18.1 d) 7)(Thermal stability- Sheath ) |
- |
2500 |
|
For BIS Samples – 1.5 times the BIS testing charges. For others : Rs. 1,75,000/- for type test of single core cable. Rs. 2,10,000/- for type test of three core cable Rs. 8500/- for additional test for C1(FR) Rs. 12500/- for additional test for C2(FR-LSH) |
18.1 d) 8)(Water absorption (gravimetric)(for insulation, where applicable)) |
- |
7000 |
|
For BIS Samples – 1.5 times the BIS testing charges. For others : Rs. 1,75,000/- for type test of single core cable. Rs. 2,10,000/- for type test of three core cable Rs. 8500/- for additional test for C1(FR) Rs. 12500/- for additional test for C2(FR-LSH) |
18.1 e)(Insulation resistance test : Volume Resistivity ) |
- |
5000 |
|
For BIS Samples – 1.5 times the BIS testing charges. For others : Rs. 1,75,000/- for type test of single core cable. Rs. 2,10,000/- for type test of three core cable Rs. 8500/- for additional test for C1(FR) Rs. 12500/- for additional test for C2(FR-LSH) |
18.1 e)(Insulation resistance test : IR Constant ) |
- |
5000 |
|
For BIS Samples – 1.5 times the BIS testing charges. For others : Rs. 1,75,000/- for type test of single core cable. Rs. 2,10,000/- for type test of three core cable Rs. 8500/- for additional test for C1(FR) Rs. 12500/- for additional test for C2(FR-LSH) |
19.2(Partial discharge test) |
- |
45000 |
|
For BIS Samples – 1.5 times the BIS testing charges. For others : Rs. 1,75,000/- for type test of single core cable. Rs. 2,10,000/- for type test of three core cable Rs. 8500/- for additional test for C1(FR) Rs. 12500/- for additional test for C2(FR-LSH) |
19.3(Bending test) |
- |
30000 |
|
For BIS Samples – 1.5 times the BIS testing charges. For others : Rs. 1,75,000/- for type test of single core cable. Rs. 2,10,000/- for type test of three core cable Rs. 8500/- for additional test for C1(FR) Rs. 12500/- for additional test for C2(FR-LSH) |
19.4(Dielectric power factor test) |
- |
30000 |
|
For BIS Samples – 1.5 times the BIS testing charges. For others : Rs. 1,75,000/- for type test of single core cable. Rs. 2,10,000/- for type test of three core cable Rs. 8500/- for additional test for C1(FR) Rs. 12500/- for additional test for C2(FR-LSH) |
19.4(Dielectric power factor test) |
- |
30000 |
|
For BIS Samples – 1.5 times the BIS testing charges. For others : Rs. 1,75,000/- for type test of single core cable. Rs. 2,10,000/- for type test of three core cable Rs. 8500/- for additional test for C1(FR) Rs. 12500/- for additional test for C2(FR-LSH) |
19.5(Heating cycle test) |
- |
25000 |
|
For BIS Samples – 1.5 times the BIS testing charges. For others : Rs. 1,75,000/- for type test of single core cable. Rs. 2,10,000/- for type test of three core cable Rs. 8500/- for additional test for C1(FR) Rs. 12500/- for additional test for C2(FR-LSH) |
19.6(Impulse withstand test) |
- |
30000 |
|
For BIS Samples – 1.5 times the BIS testing charges. For others : Rs. 1,75,000/- for type test of single core cable. Rs. 2,10,000/- for type test of three core cable Rs. 8500/- for additional test for C1(FR) Rs. 12500/- for additional test for C2(FR-LSH) |
19.7(High voltage test) |
- |
10000 |
|
For BIS Samples – 1.5 times the BIS testing charges. For others : Rs. 1,75,000/- for type test of single core cable. Rs. 2,10,000/- for type test of three core cable Rs. 8500/- for additional test for C1(FR) Rs. 12500/- for additional test for C2(FR-LSH) |
19.8(Flammability test) |
- |
2500 |
|
For BIS Samples – 1.5 times the BIS testing charges. For others : Rs. 1,75,000/- for type test of single core cable. Rs. 2,10,000/- for type test of three core cable Rs. 8500/- for additional test for C1(FR) Rs. 12500/- for additional test for C2(FR-LSH) |
19.9(Oxygen Index Test) |
- |
5000 |
|
For BIS Samples – 1.5 times the BIS testing charges. For others : Rs. 1,75,000/- for type test of single core cable. Rs. 2,10,000/- for type test of three core cable Rs. 8500/- for additional test for C1(FR) Rs. 12500/- for additional test for C2(FR-LSH) |
19.10(Flame Retardance Test on Single Cables) |
- |
5000 |
|
For BIS Samples – 1.5 times the BIS testing charges. For others : Rs. 1,75,000/- for type test of single core cable. Rs. 2,10,000/- for type test of three core cable Rs. 8500/- for additional test for C1(FR) Rs. 12500/- for additional test for C2(FR-LSH) |
19.11(Flame Retardance Test on Bunched Cables) |
- |
5000 |
|
For BIS Samples – 1.5 times the BIS testing charges. For others : Rs. 1,75,000/- for type test of single core cable. Rs. 2,10,000/- for type test of three core cable Rs. 8500/- for additional test for C1(FR) Rs. 12500/- for additional test for C2(FR-LSH) |
19.13(Test for Halogen Acid Gas Evolution) |
- |
5000 |
|
For BIS Samples – 1.5 times the BIS testing charges. For others : Rs. 1,75,000/- for type test of single core cable. Rs. 2,10,000/- for type test of three core cable Rs. 8500/- for additional test for C1(FR) Rs. 12500/- for additional test for C2(FR-LSH) |
19.14(Temperature Index) |
- |
5000 |
|
For BIS Samples – 1.5 times the BIS testing charges. For others : Rs. 1,75,000/- for type test of single core cable. Rs. 2,10,000/- for type test of three core cable Rs. 8500/- for additional test for C1(FR) Rs. 12500/- for additional test for C2(FR-LSH) |
18.4(Optional Test : Cold Impact ) |
- |
2500 |
|
For BIS Samples – 1.5 times the BIS testing charges. For others : Rs. 1,75,000/- for type test of single core cable. Rs. 2,10,000/- for type test of three core cable Rs. 8500/- for additional test for C1(FR) Rs. 12500/- for additional test for C2(FR-LSH) |
20.1(IDENTIFICATION : Manufacturer's Identification) |
- |
200 |
|
For BIS Samples – 1.5 times the BIS testing charges. For others : Rs. 1,75,000/- for type test of single core cable. Rs. 2,10,000/- for type test of three core cable Rs. 8500/- for additional test for C1(FR) Rs. 12500/- for additional test for C2(FR-LSH) |
20.2(IDENTIFICATION : Cable Identification) |
- |
200 |
|
For BIS Samples – 1.5 times the BIS testing charges. For others : Rs. 1,75,000/- for type test of single core cable. Rs. 2,10,000/- for type test of three core cable Rs. 8500/- for additional test for C1(FR) Rs. 12500/- for additional test for C2(FR-LSH) |
20.3(IDENTIFICATION : Cable Code) |
- |
200 |
|
For BIS Samples – 1.5 times the BIS testing charges. For others : Rs. 1,75,000/- for type test of single core cable. Rs. 2,10,000/- for type test of three core cable Rs. 8500/- for additional test for C1(FR) Rs. 12500/- for additional test for C2(FR-LSH) |
Cl. 18.1 d) 8)(Water absorption Test (Gravimetric)) |
- |
7000 |
|
For BIS Samples – 1.5 times the BIS testing charges. For others : Rs. 1,75,000/- for type test of single core cable. Rs. 2,10,000/- for type test of three core cable Rs. 8500/- for additional test for C1(FR) Rs. 12500/- for additional test for C2(FR-LSH) |
Cl.20.1(Manufacturer's Identification) |
- |
200 |
|
For BIS Samples – 1.5 times the BIS testing charges. For others : Rs. 1,75,000/- for type test of single core cable. Rs. 2,10,000/- for type test of three core cable Rs. 8500/- for additional test for C1(FR) Rs. 12500/- for additional test for C2(FR-LSH) |
Cl.20.2(Cable Identification) |
- |
200 |
|
For BIS Samples – 1.5 times the BIS testing charges. For others : Rs. 1,75,000/- for type test of single core cable. Rs. 2,10,000/- for type test of three core cable Rs. 8500/- for additional test for C1(FR) Rs. 12500/- for additional test for C2(FR-LSH) |
Cl.20.3(Cable Code) |
- |
200 |
|
For BIS Samples – 1.5 times the BIS testing charges. For others : Rs. 1,75,000/- for type test of single core cable. Rs. 2,10,000/- for type test of three core cable Rs. 8500/- for additional test for C1(FR) Rs. 12500/- for additional test for C2(FR-LSH) |
Cl.21.1(Packing & Marking) |
- |
200 |
|
For BIS Samples – 1.5 times the BIS testing charges. For others : Rs. 1,75,000/- for type test of single core cable. Rs. 2,10,000/- for type test of three core cable Rs. 8500/- for additional test for C1(FR) Rs. 12500/- for additional test for C2(FR-LSH) |
Cl.21.2(Packing & Marking) |
- |
200 |
|
For BIS Samples – 1.5 times the BIS testing charges. For others : Rs. 1,75,000/- for type test of single core cable. Rs. 2,10,000/- for type test of three core cable Rs. 8500/- for additional test for C1(FR) Rs. 12500/- for additional test for C2(FR-LSH) |
Cl.21.2.1(Packing & Marking) |
- |
200 |
|
For BIS Samples – 1.5 times the BIS testing charges. For others : Rs. 1,75,000/- for type test of single core cable. Rs. 2,10,000/- for type test of three core cable Rs. 8500/- for additional test for C1(FR) Rs. 12500/- for additional test for C2(FR-LSH) |
|
Complete
|
|
16 Apr, 2026 |
- Included w.e.f.05.03.2025 |
4 |
IS 7098 : Part 2 (2011) |
Crosslinked polyethylene insulated thermoplastic sheathed cables - Specification: Part 2 for working voltages from 3.3 kV up to and including 33 kV (Second Revision) |
- |
-
|
185000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
4.1(CONDUCTOR) |
- |
200 |
|
- |
4.1.1(CONDUCTOR) |
- |
200 |
|
- |
5(INSULATION) |
- |
200 |
|
- |
6(SCREENING) |
- |
200 |
|
- |
6.1.1(SCREENING : - Non-metallic — Semiconducting Compound) |
- |
200 |
|
- |
6.1.2(SCREENING : - Non-magnetic Metallic Tape for Single Core Unscreened and Unarmoured Cables) |
- |
200 |
|
- |
7(FILLERS AND INNER SHEATH) |
- |
200 |
|
- |
8.1(ARMOURING) |
- |
200 |
|
- |
8.2(ARMOURING) |
- |
200 |
|
- |
9(OUTER SHEATH ) |
- |
200 |
|
- |
10.1(CONDUCTOR) |
- |
200 |
|
- |
10.2(CONDUCTOR) |
- |
200 |
|
- |
11(CONDUCTOR SCREENING) |
- |
200 |
|
- |
12.1(INSULATION) |
- |
200 |
|
- |
12.2(INSULATION : Thickness of Insulation) |
- |
1000 |
|
- |
12.3(INSULATION : Tolerance on Thickness of Insulation) |
- |
500 |
|
- |
12.4(Eccentricity and Ovality) |
- |
1000 |
|
- |
12.5(INSULATION : Application of Insulation) |
- |
500 |
|
- |
13.1(INSULATION SCREENING) |
- |
200 |
|
- |
13.2(INSULATION SCREENING) |
- |
200 |
|
- |
13.3(INSULATION SCREENING) |
- |
200 |
|
- |
13.4(INSULATION SCREENING) |
- |
200 |
|
- |
14.1(CORE IDENTIFICATION) |
- |
200 |
|
- |
14.1.1(CORE IDENTIFICATION) |
- |
200 |
|
- |
15.1(LAVING UP OF CORES) |
- |
200 |
|
- |
16.1(INNER SHEATH (COMMON COVERING)) |
- |
200 |
|
- |
16.2(INNER SHEATH (COMMON COVERING)) |
- |
200 |
|
- |
16.2.1(INNER SHEATH (COMMON COVERING)) |
- |
200 |
|
- |
16.3(INNER SHEATH (COMMON COVERING) : Thickness of Inner Sheath) |
- |
1000 |
|
- |
16.3.1(INNER SHEATH (COMMON COVERING) : Thickness of Inner Sheath) |
- |
1000 |
|
- |
17.1(ARMOURING : Application ) |
- |
200 |
|
- |
17.1.1(ARMOURING ) |
- |
200 |
|
- |
17.1.2(ARMOURING ) |
- |
200 |
|
- |
17.1.3(ARMOURING ) |
- |
200 |
|
- |
17.2.1(ARMOURING : Type of armour ) |
- |
200 |
|
- |
17.2(ARMOURING : Coverage ) |
- |
500 |
|
- |
17.3(ARMOURING : Dimension ) |
- |
1000 |
|
- |
17.4(ARMOURING : Joints) |
- |
500 |
|
- |
16.4(ARMOURING : Resistance) |
- |
2500 |
|
- |
18.1(OUTER SHEATH) |
- |
500 |
|
- |
18.2(OUTER SHEATH: Colour) |
- |
500 |
|
- |
18.3(Thicknes of outer sheath : average ) |
- |
1000 |
|
- |
18.3(Thicknes of outer sheath : minimum ) |
- |
1000 |
|
- |
19.1 i) a)(Annealing test (for copper)) |
- |
1000 |
|
- |
19.1 i) b)(Tensile test (for aluminium) - Before stranding ) |
- |
1000 |
|
- |
19.1 i) b)(Tensile test (for aluminium) - After stranding ) |
- |
1000 |
|
- |
19.1 i) c)(Wrapping test ( for aluminium)) |
- |
1000 |
|
- |
19.1 i) d)(Resistance test - Main conductor ) |
- |
5000 |
|
- |
19.1 i) d)(Resistance test - Neutral conductor ) |
- |
5000 |
|
- |
19.1 iii) a)(Phyaical tests for insulation : Tensile Test) |
- |
2500 |
|
- |
19.1 iii) a)(Phyaical tests for insulation : Elongation ) |
- |
2500 |
|
- |
19.1 iii) b)(Phyaical tests for insulation - Ageing in air Oven : Tensile Variation ) |
- |
5000 |
|
- |
19.1 iii) b)(Phyaical tests for insulation- Ageing in air oven : Elongation Variation ) |
- |
5000 |
|
- |
19.1 iii) c)(Degree of cross linking ) |
- |
1000 |
|
- |
19.1 iii) d)(Phyaical tests for insulation : Hot set ) |
- |
2500 |
|
- |
19.1 iii) d)(Phyaical tests for insulation : Permanent set ) |
- |
2500 |
|
- |
19.1 iii) e)(Phyaical tests for insulation : Shrinkage ) |
- |
1500 |
|
- |
19.1 iii) e)(Phyaical tests for insulation : Shrinkage - Crack observed ) |
- |
1500 |
|
- |
19.1 iii) f)(Insulation: Waterabsorption(gravimetric)) |
- |
7000 |
|
- |
19.1 v) a)(Test for strippability of semiconducting strippable insulation screen
(when applicable)) |
- |
2500 |
|
- |
19.1 v) b)(Volume resistivity) |
- |
5000 |
|
- |
19.1 vi) a)(Physical tests for outer sheath : Tensile stregth ) |
- |
2500 |
|
- |
19.1 vi) b)(Physical tests for outer sheath -Ageing in air oven : Elongation ) |
- |
5000 |
|
- |
19.1 vi) b)(Physical tests for outer sheath- Ageing in air oven : Tensile stregth Variation ) |
- |
5000 |
|
- |
19.1 vi) b)(Physical tests for outer sheath -Ageing in air oven : Elongation Variation ) |
- |
5000 |
|
- |
19.1 vi) c)(Phyaical tests for Sheath : Shrinkage ) |
- |
1500 |
|
- |
19.1 vi) c)(Phyaical tests for Sheath : Shrinkage - Crack observed ) |
- |
1500 |
|
- |
19.1 vi) d)(Sheath : Hot deformation) |
- |
5000 |
|
- |
19.1 vi) e)(Loss of massIn air oven) |
- |
5000 |
|
- |
19.1 vi) f)(Sheath : Heat shock test) |
- |
2500 |
|
- |
19.1 vi) g)(Sheath : Thermalstability) |
- |
3000 |
|
- |
19.1 vi) h)(Carbon black content of polythene
sheath ) |
- |
3500 |
|
- |
19.1 vii)(Thermal ageing test for complete cable - Tensile stregth ) |
- |
5000 |
|
- |
19.1 vii)(Thermal ageing test for complete cable- Elogation ) |
- |
5000 |
|
- |
19.1 vii)(Thermal ageing test for complete cable- Resistivity ) |
- |
5000 |
|
- |
19.1 xi)(Insulation resistance test : volume resistivity ) |
- |
3500 |
|
- |
20.2(Partial discharge test) |
- |
45000 |
|
- |
20.3(Bending test) |
- |
15000 |
|
- |
20.4(Dielectric power factor test : As a function of voltage) |
- |
30000 |
|
- |
20.4(Dielectric power factor test : As a function of temperature) |
- |
30000 |
|
- |
20.5(Heating Cycle Test) |
- |
30000 |
|
- |
20.6(Impulse withstand test
(Rated voltage, kV 3.8/6.6
Impulse voltage, kV 60)) |
- |
45000 |
|
- |
20.7(High voltage test) |
- |
25000 |
|
- |
20.8(Flammability test) |
- |
5000 |
|
- |
20.1(Oxygen Index Test) |
- |
7000 |
|
- |
20.11(Flame Retardance Test on Single Cables) |
- |
3000 |
|
- |
20.12(Flame Retardance Test on Bunched Cables) |
- |
15000 |
|
- |
20.13(Test for Halogen Acid Gas Evolution) |
- |
7000 |
|
- |
20.14( Test for Smoke Density) |
- |
25000 |
|
- |
20.15(Temperature Index) |
- |
7000 |
|
- |
21.1(IDENTIFICATION : Manufacturer's Identification) |
- |
200 |
|
- |
21.2(IDENTIFICATION : Cable Identification) |
- |
200 |
|
- |
21.3(IDENTIFICATION : Cable Code) |
- |
200 |
|
- |
20.3 (a)(Partial discharge test (Bending test)) |
- |
45000 |
|
- |
20.5 (a)(PD test (heating cycle test)) |
- |
30000 |
|
- |
20.6(Impulse Withstand Test
(Rated voltage, kV 6.35/11
Impulse voltage, kV 75)) |
- |
30000 |
|
- |
20.6(Impulse Withstand Test
(Rated voltage, kV 11/11
Impulse voltage, kV 95)) |
- |
30000 |
|
- |
20.6(Impulse Withstand Test
(Rated voltage, kV 12.7/22
Impulse voltage, kV 125)) |
- |
30000 |
|
- |
20.6(Impulse Withstand Test
(Rated voltage, kV 19/33
Impulse voltage, kV 170)) |
- |
30000 |
|
- |
Cl-20.6(Impulse Withstand Test (Rated voltage, kv 33/33 Impulse voltage , kv 250)) |
- |
30000 |
|
- |
Cl. 8(Conductor) |
- |
200 |
|
- |
Cl. 8(Conductor) |
- |
200 |
|
- |
Cl. 8(Conductor) |
- |
200 |
|
- |
Cl.8 & 17(Armouring) |
- |
200 |
|
- |
Cl. 17.5(Armouring : Resistance of Armour,) |
- |
2500 |
|
- |
Cl.8 & 17(Armouring : Tensile Strength) |
- |
1500 |
|
- |
Cl.8 & 17(Armouring : Elongation) |
- |
1500 |
|
- |
Cl.8 & 17(Armouring : Torsion Test (For Round Steel Wire Only)) |
- |
1500 |
|
- |
Cl.8 & 17(Armouring: Winding Test ( For formed steel wire only)) |
- |
1500 |
|
- |
Cl.8 & 17(Armouring : Application) |
- |
200 |
|
- |
Cl.8 & 17(Armouring : Uniformity of Zinc Coating) |
- |
1500 |
|
- |
Cl.8 & 17(Armouring: Mass of Zinc Coating) |
- |
1500 |
|
- |
Cl.8 & 17(Armouring : Resistivity Test) |
- |
2500 |
|
- |
Cl.8 & 17(Armouring: Cold Impact Test (For outer Sheath)) |
- |
3500 |
|
- |
Cl. 13.5.1 and Table 7(Armouring: Resistance Test for Armouring (Other than Mining Cables)) |
- |
2500 |
|
- |
19.1 vi) a)(Physical tests for outer sheath : Elongation ) |
- |
2500 |
|
- |
19.1 vi) b)(Physical tests for outer sheath- Ageing in air oven : Tensile stregth ) |
- |
5000 |
|
- |
17.2(ARMOURING : Type of armour ) |
- |
200 |
|
- |
4.1(CONDUCTOR) |
- |
- |
|
- |
4.1.1(CONDUCTOR) |
- |
- |
|
- |
5(INSULATION) |
- |
- |
|
- |
6(SCREENING) |
- |
- |
|
- |
6.1.1(SCREENING : - Non-metallic — Semiconducting Compound) |
- |
- |
|
- |
6.1.2(SCREENING : - Non-magnetic Metallic Tape for Single Core Unscreened and Unarmoured Cables) |
- |
- |
|
- |
7(FILLERS AND INNER SHEATH) |
- |
- |
|
- |
8.1(ARMOURING) |
- |
- |
|
- |
8.2(ARMOURING) |
- |
- |
|
- |
9(OUTER SHEATH ) |
- |
- |
|
- |
10.1(CONDUCTOR) |
- |
- |
|
- |
10.2(CONDUCTOR) |
- |
- |
|
- |
11(CONDUCTOR SCREENING) |
- |
- |
|
- |
12.1(INSULATION) |
- |
- |
|
- |
12.2(INSULATION : Thickness of Insulation) |
- |
- |
|
- |
12.3(INSULATION : Tolerance on Thickness of Insulation) |
- |
- |
|
- |
12.4(Eccentricity and Ovality) |
- |
- |
|
- |
12.5(INSULATION : Application of Insulation) |
- |
- |
|
- |
13.1(INSULATION SCREENING) |
- |
- |
|
- |
13.2(INSULATION SCREENING) |
- |
- |
|
- |
13.3(INSULATION SCREENING) |
- |
- |
|
- |
13.4(INSULATION SCREENING) |
- |
- |
|
- |
14.1(CORE IDENTIFICATION) |
- |
- |
|
- |
14.1.1(CORE IDENTIFICATION) |
- |
- |
|
- |
15.1(LAVING UP OF CORES) |
- |
- |
|
- |
16.1(INNER SHEATH (COMMON COVERING)) |
- |
- |
|
- |
16.2(INNER SHEATH (COMMON COVERING)) |
- |
- |
|
- |
16.2.1(INNER SHEATH (COMMON COVERING)) |
- |
- |
|
- |
16.3(INNER SHEATH (COMMON COVERING) : Thickness of Inner Sheath) |
- |
- |
|
- |
16.3.1(INNER SHEATH (COMMON COVERING) : Thickness of Inner Sheath) |
- |
- |
|
- |
17.1(ARMOURING : Application ) |
- |
- |
|
- |
17.1.1(ARMOURING ) |
- |
- |
|
- |
17.1.2(ARMOURING ) |
- |
- |
|
- |
17.1.3(ARMOURING ) |
- |
- |
|
- |
17.2.1(ARMOURING : Type of armour ) |
- |
- |
|
- |
17.2(ARMOURING : Coverage ) |
- |
- |
|
- |
17.3(ARMOURING : Dimension ) |
- |
- |
|
- |
17.4(ARMOURING : Joints) |
- |
- |
|
- |
16.4(ARMOURING : Resistance) |
- |
- |
|
- |
18.1(OUTER SHEATH) |
- |
- |
|
- |
18.2(OUTER SHEATH: Colour) |
- |
- |
|
- |
18.3(Thicknes of outer sheath : average ) |
- |
- |
|
- |
18.3(Thicknes of outer sheath : minimum ) |
- |
- |
|
- |
19.1 i) a)(Annealing test (for copper)) |
- |
- |
|
- |
19.1 i) b)(Tensile test (for aluminium) - Before stranding ) |
- |
- |
|
- |
19.1 i) b)(Tensile test (for aluminium) - After stranding ) |
- |
- |
|
- |
19.1 i) c)(Wrapping test ( for aluminium)) |
- |
- |
|
- |
19.1 i) d)(Resistance test - Main conductor ) |
- |
- |
|
- |
19.1 i) d)(Resistance test - Neutral conductor ) |
- |
- |
|
- |
19.1 iii) a)(Phyaical tests for insulation : Tensile Test) |
- |
- |
|
- |
19.1 iii) a)(Phyaical tests for insulation : Elongation ) |
- |
- |
|
- |
19.1 iii) b)(Phyaical tests for insulation - Ageing in air Oven : Tensile Variation ) |
- |
- |
|
- |
19.1 iii) b)(Phyaical tests for insulation- Ageing in air oven : Elongation Variation ) |
- |
- |
|
- |
19.1 iii) c)(Degree of cross linking ) |
- |
- |
|
- |
19.1 iii) d)(Phyaical tests for insulation : Hot set ) |
- |
- |
|
- |
19.1 iii) d)(Phyaical tests for insulation : Permanent set ) |
- |
- |
|
- |
19.1 iii) e)(Phyaical tests for insulation : Shrinkage ) |
- |
- |
|
- |
19.1 iii) e)(Phyaical tests for insulation : Shrinkage - Crack observed ) |
- |
- |
|
- |
19.1 iii) f)(Insulation: Waterabsorption(gravimetric)) |
- |
- |
|
- |
19.1 v) a)(Test for strippability of semiconducting strippable insulation screen
(when applicable)) |
- |
- |
|
- |
19.1 v) b)(Volume resistivity) |
- |
- |
|
- |
19.1 vi) a)(Physical tests for outer sheath : Tensile stregth ) |
- |
- |
|
- |
19.1 vi) b)(Physical tests for outer sheath -Ageing in air oven : Elongation ) |
- |
- |
|
- |
19.1 vi) b)(Physical tests for outer sheath- Ageing in air oven : Tensile stregth Variation ) |
- |
- |
|
- |
19.1 vi) b)(Physical tests for outer sheath -Ageing in air oven : Elongation Variation ) |
- |
- |
|
- |
19.1 vi) c)(Phyaical tests for Sheath : Shrinkage ) |
- |
- |
|
- |
19.1 vi) c)(Phyaical tests for Sheath : Shrinkage - Crack observed ) |
- |
- |
|
- |
19.1 vi) d)(Sheath : Hot deformation) |
- |
- |
|
- |
19.1 vi) e)(Loss of massIn air oven) |
- |
- |
|
- |
19.1 vi) f)(Sheath : Heat shock test) |
- |
- |
|
- |
19.1 vi) g)(Sheath : Thermalstability) |
- |
- |
|
- |
19.1 vi) h)(Carbon black content of polythene
sheath ) |
- |
- |
|
- |
19.1 vii)(Thermal ageing test for complete cable - Tensile stregth ) |
- |
- |
|
- |
19.1 vii)(Thermal ageing test for complete cable- Elogation ) |
- |
- |
|
- |
19.1 vii)(Thermal ageing test for complete cable- Resistivity ) |
- |
- |
|
- |
19.1 xi)(Insulation resistance test : volume resistivity ) |
- |
- |
|
- |
20.2(Partial discharge test) |
- |
- |
|
- |
20.3(Bending test) |
- |
- |
|
- |
20.4(Dielectric power factor test : As a function of voltage) |
- |
- |
|
- |
20.4(Dielectric power factor test : As a function of temperature) |
- |
- |
|
- |
20.5(Heating Cycle Test) |
- |
- |
|
- |
20.6(Impulse withstand test
(Rated voltage, kV 3.8/6.6
Impulse voltage, kV 60)) |
- |
- |
|
- |
20.7(High voltage test) |
- |
- |
|
- |
20.8(Flammability test) |
- |
- |
|
- |
20.1(Oxygen Index Test) |
- |
- |
|
- |
20.11(Flame Retardance Test on Single Cables) |
- |
- |
|
- |
20.12(Flame Retardance Test on Bunched Cables) |
- |
- |
|
- |
20.13(Test for Halogen Acid Gas Evolution) |
- |
- |
|
- |
20.14( Test for Smoke Density) |
- |
- |
|
- |
20.15(Temperature Index) |
- |
- |
|
- |
21.1(IDENTIFICATION : Manufacturer's Identification) |
- |
- |
|
- |
21.2(IDENTIFICATION : Cable Identification) |
- |
- |
|
- |
21.3(IDENTIFICATION : Cable Code) |
- |
- |
|
- |
20.3 (a)(Partial discharge test (Bending test)) |
- |
- |
|
- |
20.5 (a)(PD test (heating cycle test)) |
- |
- |
|
- |
20.6(Impulse Withstand Test
(Rated voltage, kV 6.35/11
Impulse voltage, kV 75)) |
- |
- |
|
- |
20.6(Impulse Withstand Test
(Rated voltage, kV 11/11
Impulse voltage, kV 95)) |
- |
- |
|
- |
20.6(Impulse Withstand Test
(Rated voltage, kV 12.7/22
Impulse voltage, kV 125)) |
- |
- |
|
- |
20.6(Impulse Withstand Test
(Rated voltage, kV 19/33
Impulse voltage, kV 170)) |
- |
- |
|
- |
Cl-20.6(Impulse Withstand Test (Rated voltage, kv 33/33 Impulse voltage , kv 250)) |
- |
- |
|
- |
Cl. 8(Conductor) |
- |
- |
|
- |
Cl. 8(Conductor) |
- |
- |
|
- |
Cl. 8(Conductor) |
- |
- |
|
- |
Cl.8 & 17(Armouring) |
- |
- |
|
- |
Cl. 17.5(Armouring : Resistance of Armour,) |
- |
- |
|
- |
Cl.8 & 17(Armouring : Tensile Strength) |
- |
- |
|
- |
Cl.8 & 17(Armouring : Elongation) |
- |
- |
|
- |
Cl.8 & 17(Armouring : Torsion Test (For Round Steel Wire Only)) |
- |
- |
|
- |
Cl.8 & 17(Armouring: Winding Test ( For formed steel wire only)) |
- |
- |
|
- |
Cl.8 & 17(Armouring : Application) |
- |
- |
|
- |
Cl.8 & 17(Armouring : Uniformity of Zinc Coating) |
- |
- |
|
- |
Cl.8 & 17(Armouring: Mass of Zinc Coating) |
- |
- |
|
- |
Cl.8 & 17(Armouring : Resistivity Test) |
- |
- |
|
- |
Cl.8 & 17(Armouring: Cold Impact Test (For outer Sheath)) |
- |
- |
|
- |
Cl. 13.5.1 and Table 7(Armouring: Resistance Test for Armouring (Other than Mining Cables)) |
- |
- |
|
- |
19.1 vi) a)(Physical tests for outer sheath : Elongation ) |
- |
- |
|
- |
19.1 vi) b)(Physical tests for outer sheath- Ageing in air oven : Tensile stregth ) |
- |
- |
|
- |
17.2(ARMOURING : Type of armour ) |
- |
- |
|
- |
|
Complete
|
|
16 Apr, 2026 |
- Included w.e.f.05.03.2025 |
5 |
IS 17293 (2020) |
Electric Cables for Photovoltaic Systems for Rated Voltage 1 500 V d.c. |
- |
-
|
1050000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Cl. 7.3, Table 1 to 5 of IS 8130:2013 & IS:10810 (Part 5)-1984(Conductor Resistance Test) |
- |
3500 |
|
- |
Cl. 7.1.2 of IS 8130 : 2013 & IS:10810 (Part 1)-1984(Annealing Test (for copper)) |
- |
1000 |
|
- |
Cl. 7.1.1 of IS 8130:2013 & IS:10810 (Part 4)-1984(Persulphate Test for tinned copper) |
- |
1500 |
|
- |
Annex G and Table 3 of IS 17293:2020(Ozone Resistance test) |
- |
50000 |
|
- |
IS 191 : 2007, IS 440(Copper purity test) |
- |
3500 |
|
- |
Table 3 of IS 17293:2020 & IS 10810 (Part 63)(Smoke density test.) |
- |
145000 |
|
- |
Cl 6.4.3 and Table 3 of IS 8130(Diameter of wire in conductor) |
- |
100 |
|
- |
Table-3 & Annex-F of IS 17293:2020 and IS 10810 (Part 7) 1984(Elongation at low temperature (Cold Elongation)) |
- |
7000 |
|
- |
Annex H and Table 3 of IS 17293:2020(Damp Heat test) |
- |
35000 |
|
- |
Cl. 5.3, 6.3 & Table 1 & 2 & IS:10810 (Part 6)-1984(Test for overall dimensions and thickness of insulation and sheath) |
- |
1000 |
|
- |
Annex A of IS 17293-2020, IS:10810 (Part 7)-1984 & IS:10810 (Part 11)-1984(Tensile Strength and elongation at break before and after ageing.) |
- |
7000 |
|
- |
Cl 11.2.3 & Table-3 of IS 17293:2020 & IS:10810 (Part 43)-1984(Insulation Resistance) |
- |
5000 |
|
- |
Annex B of IS 17293:2020 & IS:10810 (Part 11)-1984(Ageing in air oven.) |
- |
7000 |
|
- |
Annex J (J-1, J-2, J-3 & J-4) of IS 17293:2020(pH) |
- |
7000 |
|
- |
Annex J (J-1, J-2, J-3 & J-4) of IS 17293:2020(IS 17293) |
- |
4500 |
|
- |
Annex J (J-1, J-2, J-3 & J-4) of IS 17293:2020(HCl and HBr) |
- |
4500 |
|
- |
Annex J (J-1, J-2, J-3 & J-4) of IS 17293:2020(Presence of Fluorine / Fluorine Content (if required)) |
- |
4500 |
|
- |
Annex B of IS 17293:2020 & IS:10810 (Part 30)-1984(IS 10810-30) |
- |
2000 |
|
- |
"Annex B of IS 17293:2020 & IS:8504-1:2012 and IS: 8504-2: 2013"(Thermal endurance test) |
- |
340000 |
|
- |
Annex D and Table 3 of IS 17293:2020(Dynamic Penetration test) |
- |
70000 |
|
- |
Annex- I, Annex-B, Table-11 of IS 17293:2020 and IS 10810 (Part 1) : 1984(Sheath resistance against acid and alkaline solution) |
- |
5000 |
|
- |
Annex C of IS 17293:2020 & IS:10810 (Part 21)-1984(Cold impact test) |
- |
5000 |
|
- |
Annex - B of IS 17293:2020(Compatibility test) |
- |
7000 |
|
- |
Table 3 of IS 17293:2020 & IS:10810 (Part 20)-1984(Cold bend test) |
- |
5000 |
|
- |
Cl. 5.3, 6.3 & Table 1 & 2 & IS:10810 (Part 6)-1984(Test for overall dimensions and thickness of insulation and sheath) |
- |
0 |
|
- |
Cl 5.3 of IS 17048:2018 & IS:10810 (Part 53)-1984(Flammability Test) |
- |
1500 |
|
- |
Annex A of IS 17293-2020, IS:10810 (Part 7)-1984 & IS:10810 (Part 11)-1984(Tensile Strength and elongation at break before and after ageing.) |
- |
0 |
|
- |
Cl 11.2.1 of IS 17293:2020 & IS:10810 (Part 45)-1984(High voltage test) |
- |
2500 |
|
- |
Cl 5.7 & Annex D (D.1, D.2, D.3, D.4) of IS 17048:2018.(Presence of Fluorine / Fluorine Content (if required)) |
- |
0 |
|
- |
Annex B of IS 17293:2020 & IS:10810 (Part 11)-1984(Ageing in air oven.) |
- |
0 |
|
- |
Annex J (J-1, J-2, J-3 & J-4) of IS 17293:2020(pH) |
- |
0 |
|
- |
Annex J (J-1, J-2, J-3 & J-4) of IS 17293:2020(Conductivity) |
- |
0 |
|
- |
Annex J (J-1, J-2, J-3 & J-4) of IS 17293:2020(HCl and HBr) |
- |
0 |
|
- |
Annex J (J-1, J-2, J-3 & J-4) of IS 17293:2020(Presence of Fluorine / Fluorine Content (if required)) |
- |
0 |
|
- |
Annex B of IS 17293:2020 & IS:10810 (Part 30)-1984(Hot set test) |
- |
0 |
|
- |
"Annex B of IS 17293:2020 & IS:8504-1:2012 and IS: 8504-2: 2013"(Thermal endurance test) |
- |
340000 |
|
- |
Annex- I, Annex-B, Table-11 of IS 17293:2020 and IS 10810 (Part 1) : 1984(Sheath resistance against acid and alkaline solution) |
- |
0 |
|
- |
Annex - B of IS 17293:2020(Compatibility test) |
- |
0 |
|
- |
Table 3 of IS 17293:2020 & IS:10810 (Part 12)-1984(Shrinkage test) |
- |
1500 |
|
- |
Annex - E of IS 17293 : 2020(UV resistance) |
- |
45000 |
|
- |
11.2.4(Long-term Resistance of Insulation to d.c.) |
- |
10000 |
|
- |
11.2.5(Surface Resistance of Sheath) |
- |
3500 |
|
- |
11.3.1(Sheath Colour) |
- |
1000 |
|
- |
11.3.2(Sheath Marking) |
- |
1000 |
|
- |
11.3.3(Overall Diameters and Ovality) |
- |
1000 |
|
- |
Annex J(Assessment of Halogens) |
- |
0 |
|
- |
5.1, 6.1, Table 11, 1.1(Properties before ageing b) |
- |
0 |
|
- |
5.1, 6.1, Table 11, 1.2(Properties after ageing in oven) |
- |
0 |
|
- |
5.1, 6.1, Table 11, 1.3(Hot set test b) |
- |
0 |
|
- |
5.1, 6.1, Table 11, 1.4(Thermal endurance Test conditions b) |
- |
0 |
|
- |
5.1, 6.1, Table 11, 1.5(Bending at low temperature) |
- |
0 |
|
- |
5.1, 6.1, Table 11, 1.6(Elongation at low temperature Insulated conductor/cable overall diameter) |
- |
0 |
|
- |
5.1, 6.1, Table 11, 1.7(Sheath resistance against acid and alkaline solution) |
- |
0 |
|
- |
5.1, 6.1, Table 11, 1.8(Compatibility test) |
- |
0 |
|
- |
5.2(Application to the Conductor) |
- |
500 |
|
- |
5.3(Thickness) |
- |
1000 |
|
- |
6.2(Sheath application) |
- |
500 |
|
- |
6.3(Sheath Thickness) |
- |
1000 |
|
- |
6.4(Sheath Colour) |
- |
1000 |
|
- |
7(Overall Dimension) |
- |
1000 |
|
- |
8.1(Continuity of Marking) |
- |
500 |
|
- |
8.2(Durability) |
- |
500 |
|
- |
9(Core Identification) |
- |
500 |
|
- |
4.1(Resistance) |
- |
0 |
|
- |
7.1.2.1, 7.2.3(Annealing) |
- |
0 |
|
- |
Table 3, (IS 10810 Part 53)(Test for vertical flame propagation on complete cable) |
- |
0 |
|
- |
Cl 5.7 & Annex D (D.1, D.2, D.3, D.4) of IS 17048:2018.(pH) |
- |
0 |
|
- |
Cl 5.7 & Annex D (D.1, D.2, D.3, D.4) of IS 17048:2018.(Conductivity) |
- |
0 |
|
- |
Cl 5.7 & Annex D (D.1, D.2, D.3, D.4) of IS 17048:2018.(HCl and HBr) |
- |
0 |
|
- |
Cl 5.7 & Annex D (D.1, D.2, D.3, D.4) of IS 17048:2018.(Presence of Fluorine / Fluorine Content (if required)) |
- |
0 |
|
- |
11.2.2(Spark Test) |
- |
1500 |
|
- |
12(Packing and Marking) |
- |
500 |
|
- |
8.3(Legibility) |
- |
500 |
|
- |
Cl. 7.3, Table 1 to 5 of IS 8130:2013 & IS:10810 (Part 5)-1984(Conductor Resistance Test) |
- |
3500 |
|
- |
Cl. 7.1.2 of IS 8130 : 2013 & IS:10810 (Part 1)-1984(Annealing Test (for copper)) |
- |
0 |
|
- |
Cl. 7.1.1 of IS 8130:2013 & IS:10810 (Part 4)-1984(Persulphate Test for tinned copper) |
- |
0 |
|
- |
Annex G and Table 3 of IS 17293:2020(Ozone Resistance test) |
- |
0 |
|
- |
IS 191 : 2007, IS 440(Copper purity test) |
- |
0 |
|
- |
Table 3 of IS 17293:2020 & IS 10810 (Part 63)(Smoke density test.) |
- |
0 |
|
- |
Cl 6.4.3 and Table 3 of IS 8130(Diameter of wire in conductor) |
- |
0 |
|
- |
Table-3 & Annex-F of IS 17293:2020 and IS 10810 (Part 7) 1984(Elongation at low temperature (Cold Elongation)) |
- |
0 |
|
- |
Annex H and Table 3 of IS 17293:2020(Damp Heat test) |
- |
0 |
|
- |
Cl. 5.3, 6.3 & Table 1 & 2 & IS:10810 (Part 6)-1984(Test for overall dimensions and thickness of insulation and sheath) |
- |
0 |
|
- |
Annex A of IS 17293-2020, IS:10810 (Part 7)-1984 & IS:10810 (Part 11)-1984(Tensile Strength and elongation at break before and after ageing.) |
- |
0 |
|
- |
Cl 11.2.3 & Table-3 of IS 17293:2020 & IS:10810 (Part 43)-1984(Insulation Resistance) |
- |
0 |
|
- |
Annex B of IS 17293:2020 & IS:10810 (Part 11)-1984(Ageing in air oven.) |
- |
0 |
|
- |
Annex J (J-1, J-2, J-3 & J-4) of IS 17293:2020(pH) |
- |
0 |
|
- |
Annex J (J-1, J-2, J-3 & J-4) of IS 17293:2020(IS 17293) |
- |
0 |
|
- |
Annex J (J-1, J-2, J-3 & J-4) of IS 17293:2020(HCl and HBr) |
- |
0 |
|
- |
Annex J (J-1, J-2, J-3 & J-4) of IS 17293:2020(Presence of Fluorine / Fluorine Content (if required)) |
- |
0 |
|
- |
Annex B of IS 17293:2020 & IS:10810 (Part 30)-1984(IS 10810-30) |
- |
0 |
|
- |
"Annex B of IS 17293:2020 & IS:8504-1:2012 and IS: 8504-2: 2013"(Thermal endurance test) |
- |
0 |
|
- |
Annex D and Table 3 of IS 17293:2020(Dynamic Penetration test) |
- |
0 |
|
- |
Annex- I, Annex-B, Table-11 of IS 17293:2020 and IS 10810 (Part 1) : 1984(Sheath resistance against acid and alkaline solution) |
- |
0 |
|
- |
Annex C of IS 17293:2020 & IS:10810 (Part 21)-1984(Cold impact test) |
- |
0 |
|
- |
Annex - B of IS 17293:2020(Compatibility test) |
- |
0 |
|
- |
Table 3 of IS 17293:2020 & IS:10810 (Part 20)-1984(Cold bend test) |
- |
0 |
|
- |
Cl. 5.3, 6.3 & Table 1 & 2 & IS:10810 (Part 6)-1984(Test for overall dimensions and thickness of insulation and sheath) |
- |
0 |
|
- |
Cl 5.3 of IS 17048:2018 & IS:10810 (Part 53)-1984(Flammability Test) |
- |
0 |
|
- |
Annex A of IS 17293-2020, IS:10810 (Part 7)-1984 & IS:10810 (Part 11)-1984(Tensile Strength and elongation at break before and after ageing.) |
- |
0 |
|
- |
Cl 11.2.1 of IS 17293:2020 & IS:10810 (Part 45)-1984(High voltage test) |
- |
5000 |
|
- |
Cl 5.7 & Annex D (D.1, D.2, D.3, D.4) of IS 17048:2018.(Presence of Fluorine / Fluorine Content (if required)) |
- |
0 |
|
- |
Annex B of IS 17293:2020 & IS:10810 (Part 11)-1984(Ageing in air oven.) |
- |
0 |
|
- |
Annex J (J-1, J-2, J-3 & J-4) of IS 17293:2020(pH) |
- |
0 |
|
- |
Annex J (J-1, J-2, J-3 & J-4) of IS 17293:2020(Conductivity) |
- |
0 |
|
- |
Annex J (J-1, J-2, J-3 & J-4) of IS 17293:2020(HCl and HBr) |
- |
0 |
|
- |
Annex J (J-1, J-2, J-3 & J-4) of IS 17293:2020(Presence of Fluorine / Fluorine Content (if required)) |
- |
0 |
|
- |
Annex B of IS 17293:2020 & IS:10810 (Part 30)-1984(Hot set test) |
- |
0 |
|
- |
"Annex B of IS 17293:2020 & IS:8504-1:2012 and IS: 8504-2: 2013"(Thermal endurance test) |
- |
0 |
|
- |
Annex- I, Annex-B, Table-11 of IS 17293:2020 and IS 10810 (Part 1) : 1984(Sheath resistance against acid and alkaline solution) |
- |
0 |
|
- |
Annex - B of IS 17293:2020(Compatibility test) |
- |
0 |
|
- |
Table 3 of IS 17293:2020 & IS:10810 (Part 12)-1984(Shrinkage test) |
- |
0 |
|
- |
Annex - E of IS 17293 : 2020(UV resistance) |
- |
0 |
|
- |
11.2.4(Long-term Resistance of Insulation to d.c.) |
- |
0 |
|
- |
11.2.5(Surface Resistance of Sheath) |
- |
0 |
|
- |
11.3.1(Sheath Colour) |
- |
0 |
|
- |
11.3.2(Sheath Marking) |
- |
0 |
|
- |
11.3.3(Overall Diameters and Ovality) |
- |
0 |
|
- |
Annex J(Assessment of Halogens) |
- |
0 |
|
- |
5.1, 6.1, Table 11, 1.1(Properties before ageing b) |
- |
0 |
|
- |
5.1, 6.1, Table 11, 1.2(Properties after ageing in oven) |
- |
0 |
|
- |
5.1, 6.1, Table 11, 1.3(Hot set test b) |
- |
0 |
|
- |
5.1, 6.1, Table 11, 1.4(Thermal endurance Test conditions b) |
- |
0 |
|
- |
5.1, 6.1, Table 11, 1.5(Bending at low temperature) |
- |
0 |
|
- |
5.1, 6.1, Table 11, 1.6(Elongation at low temperature Insulated conductor/cable overall diameter) |
- |
7000 |
|
- |
5.1, 6.1, Table 11, 1.7(Sheath resistance against acid and alkaline solution) |
- |
1000 |
|
- |
5.1, 6.1, Table 11, 1.8(Compatibility test) |
- |
0 |
|
- |
5.2(Application to the Conductor) |
- |
0 |
|
- |
5.3(Thickness) |
- |
0 |
|
- |
6.2(Sheath application) |
- |
0 |
|
- |
6.3(Sheath Thickness) |
- |
1000 |
|
- |
6.4(Sheath Colour) |
- |
1000 |
|
- |
7(Overall Dimension) |
- |
1000 |
|
- |
8.1(Continuity of Marking) |
- |
0 |
|
- |
8.2(Durability) |
- |
0 |
|
- |
9(Core Identification) |
- |
0 |
|
- |
4.1(Resistance) |
- |
3500 |
|
- |
7.1.2.1, 7.2.3(Annealing) |
- |
2000 |
|
- |
Table 3, (IS 10810 Part 53)(Test for vertical flame propagation on complete cable) |
- |
5000 |
|
- |
Cl 5.7 & Annex D (D.1, D.2, D.3, D.4) of IS 17048:2018.(pH) |
- |
0 |
|
- |
Cl 5.7 & Annex D (D.1, D.2, D.3, D.4) of IS 17048:2018.(Conductivity) |
- |
0 |
|
- |
Cl 5.7 & Annex D (D.1, D.2, D.3, D.4) of IS 17048:2018.(HCl and HBr) |
- |
0 |
|
- |
Cl 5.7 & Annex D (D.1, D.2, D.3, D.4) of IS 17048:2018.(Presence of Fluorine / Fluorine Content (if required)) |
- |
0 |
|
- |
11.2.2(Spark Test) |
- |
0 |
|
- |
12(Packing and Marking) |
- |
0 |
|
- |
8.3(Legibility) |
- |
0 |
|
- |
Cl. 7.3, Table 1 to 5 of IS 8130:2013 & IS:10810 (Part 5)-1984(Conductor Resistance Test) |
- |
0 |
|
- |
Cl. 7.1.2 of IS 8130 : 2013 & IS:10810 (Part 1)-1984(Annealing Test (for copper)) |
- |
0 |
|
- |
Cl. 7.1.1 of IS 8130:2013 & IS:10810 (Part 4)-1984(Persulphate Test for tinned copper) |
- |
0 |
|
- |
Annex G and Table 3 of IS 17293:2020(Ozone Resistance test) |
- |
0 |
|
- |
IS 191 : 2007, IS 440(Copper purity test) |
- |
0 |
|
- |
Table 3 of IS 17293:2020 & IS 10810 (Part 63)(Smoke density test.) |
- |
0 |
|
- |
Cl 6.4.3 and Table 3 of IS 8130(Diameter of wire in conductor) |
- |
0 |
|
- |
Table-3 & Annex-F of IS 17293:2020 and IS 10810 (Part 7) 1984(Elongation at low temperature (Cold Elongation)) |
- |
0 |
|
- |
Annex H and Table 3 of IS 17293:2020(Damp Heat test) |
- |
0 |
|
- |
Cl. 5.3, 6.3 & Table 1 & 2 & IS:10810 (Part 6)-1984(Test for overall dimensions and thickness of insulation and sheath) |
- |
0 |
|
- |
Annex A of IS 17293-2020, IS:10810 (Part 7)-1984 & IS:10810 (Part 11)-1984(Tensile Strength and elongation at break before and after ageing.) |
- |
0 |
|
- |
Cl 11.2.3 & Table-3 of IS 17293:2020 & IS:10810 (Part 43)-1984(Insulation Resistance) |
- |
0 |
|
- |
Annex B of IS 17293:2020 & IS:10810 (Part 11)-1984(Ageing in air oven.) |
- |
0 |
|
- |
Annex J (J-1, J-2, J-3 & J-4) of IS 17293:2020(pH) |
- |
0 |
|
- |
Annex J (J-1, J-2, J-3 & J-4) of IS 17293:2020(IS 17293) |
- |
0 |
|
- |
Annex J (J-1, J-2, J-3 & J-4) of IS 17293:2020(HCl and HBr) |
- |
0 |
|
- |
Annex J (J-1, J-2, J-3 & J-4) of IS 17293:2020(Presence of Fluorine / Fluorine Content (if required)) |
- |
0 |
|
- |
Annex B of IS 17293:2020 & IS:10810 (Part 30)-1984(IS 10810-30) |
- |
0 |
|
- |
"Annex B of IS 17293:2020 & IS:8504-1:2012 and IS: 8504-2: 2013"(Thermal endurance test) |
- |
0 |
|
- |
Annex D and Table 3 of IS 17293:2020(Dynamic Penetration test) |
- |
0 |
|
- |
Annex- I, Annex-B, Table-11 of IS 17293:2020 and IS 10810 (Part 1) : 1984(Sheath resistance against acid and alkaline solution) |
- |
0 |
|
- |
Annex C of IS 17293:2020 & IS:10810 (Part 21)-1984(Cold impact test) |
- |
0 |
|
- |
Annex - B of IS 17293:2020(Compatibility test) |
- |
0 |
|
- |
Table 3 of IS 17293:2020 & IS:10810 (Part 20)-1984(Cold bend test) |
- |
0 |
|
- |
Cl. 5.3, 6.3 & Table 1 & 2 & IS:10810 (Part 6)-1984(Test for overall dimensions and thickness of insulation and sheath) |
- |
0 |
|
- |
Cl 5.3 of IS 17048:2018 & IS:10810 (Part 53)-1984(Flammability Test) |
- |
0 |
|
- |
Annex A of IS 17293-2020, IS:10810 (Part 7)-1984 & IS:10810 (Part 11)-1984(Tensile Strength and elongation at break before and after ageing.) |
- |
0 |
|
- |
Cl 11.2.1 of IS 17293:2020 & IS:10810 (Part 45)-1984(High voltage test) |
- |
0 |
|
- |
Cl 5.7 & Annex D (D.1, D.2, D.3, D.4) of IS 17048:2018.(Presence of Fluorine / Fluorine Content (if required)) |
- |
0 |
|
- |
Annex B of IS 17293:2020 & IS:10810 (Part 11)-1984(Ageing in air oven.) |
- |
0 |
|
- |
Annex J (J-1, J-2, J-3 & J-4) of IS 17293:2020(pH) |
- |
0 |
|
- |
Annex J (J-1, J-2, J-3 & J-4) of IS 17293:2020(Conductivity) |
- |
0 |
|
- |
Annex J (J-1, J-2, J-3 & J-4) of IS 17293:2020(HCl and HBr) |
- |
0 |
|
- |
Annex J (J-1, J-2, J-3 & J-4) of IS 17293:2020(Presence of Fluorine / Fluorine Content (if required)) |
- |
0 |
|
- |
Annex B of IS 17293:2020 & IS:10810 (Part 30)-1984(Hot set test) |
- |
0 |
|
- |
"Annex B of IS 17293:2020 & IS:8504-1:2012 and IS: 8504-2: 2013"(Thermal endurance test) |
- |
0 |
|
- |
Annex- I, Annex-B, Table-11 of IS 17293:2020 and IS 10810 (Part 1) : 1984(Sheath resistance against acid and alkaline solution) |
- |
0 |
|
- |
Annex - B of IS 17293:2020(Compatibility test) |
- |
0 |
|
- |
Table 3 of IS 17293:2020 & IS:10810 (Part 12)-1984(Shrinkage test) |
- |
0 |
|
- |
Annex - E of IS 17293 : 2020(UV resistance) |
- |
0 |
|
- |
11.2.4(Long-term Resistance of Insulation to d.c.) |
- |
0 |
|
- |
11.2.5(Surface Resistance of Sheath) |
- |
0 |
|
- |
11.3.1(Sheath Colour) |
- |
0 |
|
- |
11.3.2(Sheath Marking) |
- |
0 |
|
- |
11.3.3(Overall Diameters and Ovality) |
- |
0 |
|
- |
Annex J(Assessment of Halogens) |
- |
0 |
|
- |
5.1, 6.1, Table 11, 1.1(Properties before ageing b) |
- |
0 |
|
- |
5.1, 6.1, Table 11, 1.2(Properties after ageing in oven) |
- |
0 |
|
- |
5.1, 6.1, Table 11, 1.3(Hot set test b) |
- |
0 |
|
- |
5.1, 6.1, Table 11, 1.4(Thermal endurance Test conditions b) |
- |
0 |
|
- |
5.1, 6.1, Table 11, 1.5(Bending at low temperature) |
- |
0 |
|
- |
5.1, 6.1, Table 11, 1.6(Elongation at low temperature Insulated conductor/cable overall diameter) |
- |
0 |
|
- |
5.1, 6.1, Table 11, 1.7(Sheath resistance against acid and alkaline solution) |
- |
0 |
|
- |
5.1, 6.1, Table 11, 1.8(Compatibility test) |
- |
0 |
|
- |
5.2(Application to the Conductor) |
- |
0 |
|
- |
5.3(Thickness) |
- |
0 |
|
- |
6.2(Sheath application) |
- |
0 |
|
- |
6.3(Sheath Thickness) |
- |
0 |
|
- |
6.4(Sheath Colour) |
- |
0 |
|
- |
7(Overall Dimension) |
- |
0 |
|
- |
8.1(Continuity of Marking) |
- |
0 |
|
- |
8.2(Durability) |
- |
0 |
|
- |
9(Core Identification) |
- |
0 |
|
- |
4.1(Resistance) |
- |
0 |
|
- |
7.1.2.1, 7.2.3(Annealing) |
- |
0 |
|
- |
Table 3, (IS 10810 Part 53)(Test for vertical flame propagation on complete cable) |
- |
0 |
|
- |
Cl 5.7 & Annex D (D.1, D.2, D.3, D.4) of IS 17048:2018.(pH) |
- |
0 |
|
- |
Cl 5.7 & Annex D (D.1, D.2, D.3, D.4) of IS 17048:2018.(Conductivity) |
- |
0 |
|
- |
Cl 5.7 & Annex D (D.1, D.2, D.3, D.4) of IS 17048:2018.(HCl and HBr) |
- |
0 |
|
- |
Cl 5.7 & Annex D (D.1, D.2, D.3, D.4) of IS 17048:2018.(Presence of Fluorine / Fluorine Content (if required)) |
- |
0 |
|
- |
11.2.2(Spark Test) |
- |
0 |
|
- |
12(Packing and Marking) |
- |
0 |
|
- |
8.3(Legibility) |
- |
0 |
|
- |
Cl. 7.3, Table 1 to 5 of IS 8130:2013 & IS:10810 (Part 5)-1984(Conductor Resistance Test) |
- |
0 |
|
- |
Cl. 7.1.2 of IS 8130 : 2013 & IS:10810 (Part 1)-1984(Annealing Test (for copper)) |
- |
0 |
|
- |
Cl. 7.1.1 of IS 8130:2013 & IS:10810 (Part 4)-1984(Persulphate Test for tinned copper) |
- |
0 |
|
- |
Annex G and Table 3 of IS 17293:2020(Ozone Resistance test) |
- |
0 |
|
- |
IS 191 : 2007, IS 440(Copper purity test) |
- |
0 |
|
- |
Table 3 of IS 17293:2020 & IS 10810 (Part 63)(Smoke density test.) |
- |
0 |
|
- |
Cl 6.4.3 and Table 3 of IS 8130(Diameter of wire in conductor) |
- |
0 |
|
- |
Table-3 & Annex-F of IS 17293:2020 and IS 10810 (Part 7) 1984(Elongation at low temperature (Cold Elongation)) |
- |
0 |
|
- |
Annex H and Table 3 of IS 17293:2020(Damp Heat test) |
- |
0 |
|
- |
Cl. 5.3, 6.3 & Table 1 & 2 & IS:10810 (Part 6)-1984(Test for overall dimensions and thickness of insulation and sheath) |
- |
0 |
|
- |
Annex A of IS 17293-2020, IS:10810 (Part 7)-1984 & IS:10810 (Part 11)-1984(Tensile Strength and elongation at break before and after ageing.) |
- |
0 |
|
- |
Cl 11.2.3 & Table-3 of IS 17293:2020 & IS:10810 (Part 43)-1984(Insulation Resistance) |
- |
0 |
|
- |
Annex B of IS 17293:2020 & IS:10810 (Part 11)-1984(Ageing in air oven.) |
- |
0 |
|
- |
Annex J (J-1, J-2, J-3 & J-4) of IS 17293:2020(pH) |
- |
0 |
|
- |
Annex J (J-1, J-2, J-3 & J-4) of IS 17293:2020(IS 17293) |
- |
0 |
|
- |
Annex J (J-1, J-2, J-3 & J-4) of IS 17293:2020(HCl and HBr) |
- |
0 |
|
- |
Annex J (J-1, J-2, J-3 & J-4) of IS 17293:2020(Presence of Fluorine / Fluorine Content (if required)) |
- |
0 |
|
- |
Annex B of IS 17293:2020 & IS:10810 (Part 30)-1984(IS 10810-30) |
- |
0 |
|
- |
"Annex B of IS 17293:2020 & IS:8504-1:2012 and IS: 8504-2: 2013"(Thermal endurance test) |
- |
0 |
|
- |
Annex D and Table 3 of IS 17293:2020(Dynamic Penetration test) |
- |
0 |
|
- |
Annex- I, Annex-B, Table-11 of IS 17293:2020 and IS 10810 (Part 1) : 1984(Sheath resistance against acid and alkaline solution) |
- |
0 |
|
- |
Annex C of IS 17293:2020 & IS:10810 (Part 21)-1984(Cold impact test) |
- |
0 |
|
- |
Annex - B of IS 17293:2020(Compatibility test) |
- |
0 |
|
- |
Table 3 of IS 17293:2020 & IS:10810 (Part 20)-1984(Cold bend test) |
- |
0 |
|
- |
Cl. 5.3, 6.3 & Table 1 & 2 & IS:10810 (Part 6)-1984(Test for overall dimensions and thickness of insulation and sheath) |
- |
0 |
|
- |
Cl 5.3 of IS 17048:2018 & IS:10810 (Part 53)-1984(Flammability Test) |
- |
0 |
|
- |
Annex A of IS 17293-2020, IS:10810 (Part 7)-1984 & IS:10810 (Part 11)-1984(Tensile Strength and elongation at break before and after ageing.) |
- |
0 |
|
- |
Cl 11.2.1 of IS 17293:2020 & IS:10810 (Part 45)-1984(High voltage test) |
- |
0 |
|
- |
Cl 5.7 & Annex D (D.1, D.2, D.3, D.4) of IS 17048:2018.(Presence of Fluorine / Fluorine Content (if required)) |
- |
0 |
|
- |
Annex B of IS 17293:2020 & IS:10810 (Part 11)-1984(Ageing in air oven.) |
- |
0 |
|
- |
Annex J (J-1, J-2, J-3 & J-4) of IS 17293:2020(pH) |
- |
0 |
|
- |
Annex J (J-1, J-2, J-3 & J-4) of IS 17293:2020(Conductivity) |
- |
0 |
|
- |
Annex J (J-1, J-2, J-3 & J-4) of IS 17293:2020(HCl and HBr) |
- |
0 |
|
- |
Annex J (J-1, J-2, J-3 & J-4) of IS 17293:2020(Presence of Fluorine / Fluorine Content (if required)) |
- |
0 |
|
- |
Annex B of IS 17293:2020 & IS:10810 (Part 30)-1984(Hot set test) |
- |
0 |
|
- |
"Annex B of IS 17293:2020 & IS:8504-1:2012 and IS: 8504-2: 2013"(Thermal endurance test) |
- |
0 |
|
- |
Annex- I, Annex-B, Table-11 of IS 17293:2020 and IS 10810 (Part 1) : 1984(Sheath resistance against acid and alkaline solution) |
- |
0 |
|
- |
Annex - B of IS 17293:2020(Compatibility test) |
- |
0 |
|
- |
Table 3 of IS 17293:2020 & IS:10810 (Part 12)-1984(Shrinkage test) |
- |
0 |
|
- |
Annex - E of IS 17293 : 2020(UV resistance) |
- |
0 |
|
- |
11.2.4(Long-term Resistance of Insulation to d.c.) |
- |
0 |
|
- |
11.2.5(Surface Resistance of Sheath) |
- |
0 |
|
- |
11.3.1(Sheath Colour) |
- |
0 |
|
- |
11.3.2(Sheath Marking) |
- |
0 |
|
- |
11.3.3(Overall Diameters and Ovality) |
- |
0 |
|
- |
Annex J(Assessment of Halogens) |
- |
0 |
|
- |
5.1, 6.1, Table 11, 1.1(Properties before ageing b) |
- |
0 |
|
- |
5.1, 6.1, Table 11, 1.2(Properties after ageing in oven) |
- |
0 |
|
- |
5.1, 6.1, Table 11, 1.3(Hot set test b) |
- |
0 |
|
- |
5.1, 6.1, Table 11, 1.4(Thermal endurance Test conditions b) |
- |
0 |
|
- |
5.1, 6.1, Table 11, 1.5(Bending at low temperature) |
- |
0 |
|
- |
5.1, 6.1, Table 11, 1.6(Elongation at low temperature Insulated conductor/cable overall diameter) |
- |
0 |
|
- |
5.1, 6.1, Table 11, 1.7(Sheath resistance against acid and alkaline solution) |
- |
0 |
|
- |
5.1, 6.1, Table 11, 1.8(Compatibility test) |
- |
0 |
|
- |
5.2(Application to the Conductor) |
- |
0 |
|
- |
5.3(Thickness) |
- |
0 |
|
- |
6.2(Sheath application) |
- |
0 |
|
- |
6.3(Sheath Thickness) |
- |
0 |
|
- |
6.4(Sheath Colour) |
- |
0 |
|
- |
7(Overall Dimension) |
- |
0 |
|
- |
8.1(Continuity of Marking) |
- |
0 |
|
- |
8.2(Durability) |
- |
0 |
|
- |
9(Core Identification) |
- |
0 |
|
- |
4.1(Resistance) |
- |
0 |
|
- |
7.1.2.1, 7.2.3(Annealing) |
- |
0 |
|
- |
Table 3, (IS 10810 Part 53)(Test for vertical flame propagation on complete cable) |
- |
0 |
|
- |
Cl 5.7 & Annex D (D.1, D.2, D.3, D.4) of IS 17048:2018.(pH) |
- |
0 |
|
- |
Cl 5.7 & Annex D (D.1, D.2, D.3, D.4) of IS 17048:2018.(Conductivity) |
- |
0 |
|
- |
Cl 5.7 & Annex D (D.1, D.2, D.3, D.4) of IS 17048:2018.(HCl and HBr) |
- |
0 |
|
- |
Cl 5.7 & Annex D (D.1, D.2, D.3, D.4) of IS 17048:2018.(Presence of Fluorine / Fluorine Content (if required)) |
- |
0 |
|
- |
11.2.2(Spark Test) |
- |
0 |
|
- |
12(Packing and Marking) |
- |
0 |
|
- |
8.3(Legibility) |
- |
0 |
|
- |
Cl. 7.3, Table 1 to 5 of IS 8130:2013 & IS:10810 (Part 5)-1984(Conductor Resistance Test) |
- |
0 |
|
- |
Cl. 7.1.2 of IS 8130 : 2013 & IS:10810 (Part 1)-1984(Annealing Test (for copper)) |
- |
0 |
|
- |
Cl. 7.1.1 of IS 8130:2013 & IS:10810 (Part 4)-1984(Persulphate Test for tinned copper) |
- |
0 |
|
- |
Annex G and Table 3 of IS 17293:2020(Ozone Resistance test) |
- |
0 |
|
- |
IS 191 : 2007, IS 440(Copper purity test) |
- |
0 |
|
- |
Table 3 of IS 17293:2020 & IS 10810 (Part 63)(Smoke density test.) |
- |
0 |
|
- |
Cl 6.4.3 and Table 3 of IS 8130(Diameter of wire in conductor) |
- |
0 |
|
- |
Table-3 & Annex-F of IS 17293:2020 and IS 10810 (Part 7) 1984(Elongation at low temperature (Cold Elongation)) |
- |
0 |
|
- |
Annex H and Table 3 of IS 17293:2020(Damp Heat test) |
- |
0 |
|
- |
Cl. 5.3, 6.3 & Table 1 & 2 & IS:10810 (Part 6)-1984(Test for overall dimensions and thickness of insulation and sheath) |
- |
0 |
|
- |
Annex A of IS 17293-2020, IS:10810 (Part 7)-1984 & IS:10810 (Part 11)-1984(Tensile Strength and elongation at break before and after ageing.) |
- |
0 |
|
- |
Cl 11.2.3 & Table-3 of IS 17293:2020 & IS:10810 (Part 43)-1984(Insulation Resistance) |
- |
0 |
|
- |
Annex B of IS 17293:2020 & IS:10810 (Part 11)-1984(Ageing in air oven.) |
- |
0 |
|
- |
Annex J (J-1, J-2, J-3 & J-4) of IS 17293:2020(pH) |
- |
0 |
|
- |
Annex J (J-1, J-2, J-3 & J-4) of IS 17293:2020(IS 17293) |
- |
0 |
|
- |
Annex J (J-1, J-2, J-3 & J-4) of IS 17293:2020(HCl and HBr) |
- |
0 |
|
- |
Annex J (J-1, J-2, J-3 & J-4) of IS 17293:2020(Presence of Fluorine / Fluorine Content (if required)) |
- |
0 |
|
- |
Annex B of IS 17293:2020 & IS:10810 (Part 30)-1984(IS 10810-30) |
- |
0 |
|
- |
"Annex B of IS 17293:2020 & IS:8504-1:2012 and IS: 8504-2: 2013"(Thermal endurance test) |
- |
0 |
|
- |
Annex D and Table 3 of IS 17293:2020(Dynamic Penetration test) |
- |
0 |
|
- |
Annex- I, Annex-B, Table-11 of IS 17293:2020 and IS 10810 (Part 1) : 1984(Sheath resistance against acid and alkaline solution) |
- |
0 |
|
- |
Annex C of IS 17293:2020 & IS:10810 (Part 21)-1984(Cold impact test) |
- |
0 |
|
- |
Annex - B of IS 17293:2020(Compatibility test) |
- |
0 |
|
- |
Table 3 of IS 17293:2020 & IS:10810 (Part 20)-1984(Cold bend test) |
- |
0 |
|
- |
Cl. 5.3, 6.3 & Table 1 & 2 & IS:10810 (Part 6)-1984(Test for overall dimensions and thickness of insulation and sheath) |
- |
0 |
|
- |
Cl 5.3 of IS 17048:2018 & IS:10810 (Part 53)-1984(Flammability Test) |
- |
0 |
|
- |
Annex A of IS 17293-2020, IS:10810 (Part 7)-1984 & IS:10810 (Part 11)-1984(Tensile Strength and elongation at break before and after ageing.) |
- |
0 |
|
- |
Cl 11.2.1 of IS 17293:2020 & IS:10810 (Part 45)-1984(High voltage test) |
- |
0 |
|
- |
Cl 5.7 & Annex D (D.1, D.2, D.3, D.4) of IS 17048:2018.(Presence of Fluorine / Fluorine Content (if required)) |
- |
0 |
|
- |
Annex B of IS 17293:2020 & IS:10810 (Part 11)-1984(Ageing in air oven.) |
- |
0 |
|
- |
Annex J (J-1, J-2, J-3 & J-4) of IS 17293:2020(pH) |
- |
0 |
|
- |
Annex J (J-1, J-2, J-3 & J-4) of IS 17293:2020(Conductivity) |
- |
0 |
|
- |
Annex J (J-1, J-2, J-3 & J-4) of IS 17293:2020(HCl and HBr) |
- |
0 |
|
- |
Annex J (J-1, J-2, J-3 & J-4) of IS 17293:2020(Presence of Fluorine / Fluorine Content (if required)) |
- |
0 |
|
- |
Annex B of IS 17293:2020 & IS:10810 (Part 30)-1984(Hot set test) |
- |
0 |
|
- |
"Annex B of IS 17293:2020 & IS:8504-1:2012 and IS: 8504-2: 2013"(Thermal endurance test) |
- |
0 |
|
- |
Annex- I, Annex-B, Table-11 of IS 17293:2020 and IS 10810 (Part 1) : 1984(Sheath resistance against acid and alkaline solution) |
- |
0 |
|
- |
Annex - B of IS 17293:2020(Compatibility test) |
- |
0 |
|
- |
Table 3 of IS 17293:2020 & IS:10810 (Part 12)-1984(Shrinkage test) |
- |
0 |
|
- |
Annex - E of IS 17293 : 2020(UV resistance) |
- |
0 |
|
- |
11.2.4(Long-term Resistance of Insulation to d.c.) |
- |
0 |
|
- |
11.2.5(Surface Resistance of Sheath) |
- |
0 |
|
- |
11.3.1(Sheath Colour) |
- |
0 |
|
- |
11.3.2(Sheath Marking) |
- |
0 |
|
- |
11.3.3(Overall Diameters and Ovality) |
- |
0 |
|
- |
Annex J(Assessment of Halogens) |
- |
0 |
|
- |
5.1, 6.1, Table 11, 1.1(Properties before ageing b) |
- |
0 |
|
- |
5.1, 6.1, Table 11, 1.2(Properties after ageing in oven) |
- |
0 |
|
- |
5.1, 6.1, Table 11, 1.3(Hot set test b) |
- |
0 |
|
- |
5.1, 6.1, Table 11, 1.4(Thermal endurance Test conditions b) |
- |
0 |
|
- |
5.1, 6.1, Table 11, 1.5(Bending at low temperature) |
- |
0 |
|
- |
5.1, 6.1, Table 11, 1.6(Elongation at low temperature Insulated conductor/cable overall diameter) |
- |
0 |
|
- |
5.1, 6.1, Table 11, 1.7(Sheath resistance against acid and alkaline solution) |
- |
0 |
|
- |
5.1, 6.1, Table 11, 1.8(Compatibility test) |
- |
0 |
|
- |
5.2(Application to the Conductor) |
- |
0 |
|
- |
5.3(Thickness) |
- |
0 |
|
- |
6.2(Sheath application) |
- |
0 |
|
- |
6.3(Sheath Thickness) |
- |
0 |
|
- |
6.4(Sheath Colour) |
- |
0 |
|
- |
7(Overall Dimension) |
- |
0 |
|
- |
8.1(Continuity of Marking) |
- |
0 |
|
- |
8.2(Durability) |
- |
0 |
|
- |
9(Core Identification) |
- |
0 |
|
- |
4.1(Resistance) |
- |
0 |
|
- |
7.1.2.1, 7.2.3(Annealing) |
- |
0 |
|
- |
Table 3, (IS 10810 Part 53)(Test for vertical flame propagation on complete cable) |
- |
0 |
|
- |
Cl 5.7 & Annex D (D.1, D.2, D.3, D.4) of IS 17048:2018.(pH) |
- |
0 |
|
- |
Cl 5.7 & Annex D (D.1, D.2, D.3, D.4) of IS 17048:2018.(Conductivity) |
- |
0 |
|
- |
Cl 5.7 & Annex D (D.1, D.2, D.3, D.4) of IS 17048:2018.(HCl and HBr) |
- |
0 |
|
- |
Cl 5.7 & Annex D (D.1, D.2, D.3, D.4) of IS 17048:2018.(Presence of Fluorine / Fluorine Content (if required)) |
- |
0 |
|
- |
11.2.2(Spark Test) |
- |
0 |
|
- |
12(Packing and Marking) |
- |
0 |
|
- |
8.3(Legibility) |
- |
0 |
|
- |
Cl. 7.3, Table 1 to 5 of IS 8130:2013 & IS:10810 (Part 5)-1984(Conductor Resistance Test) |
- |
0 |
|
- |
Cl. 7.1.2 of IS 8130 : 2013 & IS:10810 (Part 1)-1984(Annealing Test (for copper)) |
- |
0 |
|
- |
Cl. 7.1.1 of IS 8130:2013 & IS:10810 (Part 4)-1984(Persulphate Test for tinned copper) |
- |
0 |
|
- |
Annex G and Table 3 of IS 17293:2020(Ozone Resistance test) |
- |
0 |
|
- |
IS 191 : 2007, IS 440(Copper purity test) |
- |
0 |
|
- |
Table 3 of IS 17293:2020 & IS 10810 (Part 63)(Smoke density test.) |
- |
0 |
|
- |
Cl 6.4.3 and Table 3 of IS 8130(Diameter of wire in conductor) |
- |
0 |
|
- |
Table-3 & Annex-F of IS 17293:2020 and IS 10810 (Part 7) 1984(Elongation at low temperature (Cold Elongation)) |
- |
0 |
|
- |
Annex H and Table 3 of IS 17293:2020(Damp Heat test) |
- |
0 |
|
- |
Cl. 5.3, 6.3 & Table 1 & 2 & IS:10810 (Part 6)-1984(Test for overall dimensions and thickness of insulation and sheath) |
- |
0 |
|
- |
Annex A of IS 17293-2020, IS:10810 (Part 7)-1984 & IS:10810 (Part 11)-1984(Tensile Strength and elongation at break before and after ageing.) |
- |
0 |
|
- |
Cl 11.2.3 & Table-3 of IS 17293:2020 & IS:10810 (Part 43)-1984(Insulation Resistance) |
- |
0 |
|
- |
Annex B of IS 17293:2020 & IS:10810 (Part 11)-1984(Ageing in air oven.) |
- |
0 |
|
- |
Annex J (J-1, J-2, J-3 & J-4) of IS 17293:2020(pH) |
- |
0 |
|
- |
Annex J (J-1, J-2, J-3 & J-4) of IS 17293:2020(IS 17293) |
- |
0 |
|
- |
Annex J (J-1, J-2, J-3 & J-4) of IS 17293:2020(HCl and HBr) |
- |
0 |
|
- |
Annex J (J-1, J-2, J-3 & J-4) of IS 17293:2020(Presence of Fluorine / Fluorine Content (if required)) |
- |
0 |
|
- |
Annex B of IS 17293:2020 & IS:10810 (Part 30)-1984(IS 10810-30) |
- |
0 |
|
- |
"Annex B of IS 17293:2020 & IS:8504-1:2012 and IS: 8504-2: 2013"(Thermal endurance test) |
- |
0 |
|
- |
Annex D and Table 3 of IS 17293:2020(Dynamic Penetration test) |
- |
0 |
|
- |
Annex- I, Annex-B, Table-11 of IS 17293:2020 and IS 10810 (Part 1) : 1984(Sheath resistance against acid and alkaline solution) |
- |
0 |
|
- |
Annex C of IS 17293:2020 & IS:10810 (Part 21)-1984(Cold impact test) |
- |
0 |
|
- |
Annex - B of IS 17293:2020(Compatibility test) |
- |
0 |
|
- |
Table 3 of IS 17293:2020 & IS:10810 (Part 20)-1984(Cold bend test) |
- |
0 |
|
- |
Cl. 5.3, 6.3 & Table 1 & 2 & IS:10810 (Part 6)-1984(Test for overall dimensions and thickness of insulation and sheath) |
- |
0 |
|
- |
Cl 5.3 of IS 17048:2018 & IS:10810 (Part 53)-1984(Flammability Test) |
- |
0 |
|
- |
Annex A of IS 17293-2020, IS:10810 (Part 7)-1984 & IS:10810 (Part 11)-1984(Tensile Strength and elongation at break before and after ageing.) |
- |
0 |
|
- |
Cl 11.2.1 of IS 17293:2020 & IS:10810 (Part 45)-1984(High voltage test) |
- |
0 |
|
- |
Cl 5.7 & Annex D (D.1, D.2, D.3, D.4) of IS 17048:2018.(Presence of Fluorine / Fluorine Content (if required)) |
- |
0 |
|
- |
Annex B of IS 17293:2020 & IS:10810 (Part 11)-1984(Ageing in air oven.) |
- |
0 |
|
- |
Annex J (J-1, J-2, J-3 & J-4) of IS 17293:2020(pH) |
- |
0 |
|
- |
Annex J (J-1, J-2, J-3 & J-4) of IS 17293:2020(Conductivity) |
- |
0 |
|
- |
Annex J (J-1, J-2, J-3 & J-4) of IS 17293:2020(HCl and HBr) |
- |
0 |
|
- |
Annex J (J-1, J-2, J-3 & J-4) of IS 17293:2020(Presence of Fluorine / Fluorine Content (if required)) |
- |
0 |
|
- |
Annex B of IS 17293:2020 & IS:10810 (Part 30)-1984(Hot set test) |
- |
0 |
|
- |
"Annex B of IS 17293:2020 & IS:8504-1:2012 and IS: 8504-2: 2013"(Thermal endurance test) |
- |
0 |
|
- |
Annex- I, Annex-B, Table-11 of IS 17293:2020 and IS 10810 (Part 1) : 1984(Sheath resistance against acid and alkaline solution) |
- |
0 |
|
- |
Annex - B of IS 17293:2020(Compatibility test) |
- |
0 |
|
- |
Table 3 of IS 17293:2020 & IS:10810 (Part 12)-1984(Shrinkage test) |
- |
0 |
|
- |
Annex - E of IS 17293 : 2020(UV resistance) |
- |
0 |
|
- |
11.2.4(Long-term Resistance of Insulation to d.c.) |
- |
0 |
|
- |
11.2.5(Surface Resistance of Sheath) |
- |
0 |
|
- |
11.3.1(Sheath Colour) |
- |
0 |
|
- |
11.3.2(Sheath Marking) |
- |
0 |
|
- |
11.3.3(Overall Diameters and Ovality) |
- |
0 |
|
- |
Annex J(Assessment of Halogens) |
- |
0 |
|
- |
5.1, 6.1, Table 11, 1.1(Properties before ageing b) |
- |
0 |
|
- |
5.1, 6.1, Table 11, 1.2(Properties after ageing in oven) |
- |
0 |
|
- |
5.1, 6.1, Table 11, 1.3(Hot set test b) |
- |
0 |
|
- |
5.1, 6.1, Table 11, 1.4(Thermal endurance Test conditions b) |
- |
0 |
|
- |
5.1, 6.1, Table 11, 1.5(Bending at low temperature) |
- |
0 |
|
- |
5.1, 6.1, Table 11, 1.6(Elongation at low temperature Insulated conductor/cable overall diameter) |
- |
0 |
|
- |
5.1, 6.1, Table 11, 1.7(Sheath resistance against acid and alkaline solution) |
- |
0 |
|
- |
5.1, 6.1, Table 11, 1.8(Compatibility test) |
- |
0 |
|
- |
5.2(Application to the Conductor) |
- |
0 |
|
- |
5.3(Thickness) |
- |
0 |
|
- |
6.2(Sheath application) |
- |
0 |
|
- |
6.3(Sheath Thickness) |
- |
0 |
|
- |
6.4(Sheath Colour) |
- |
0 |
|
- |
7(Overall Dimension) |
- |
0 |
|
- |
8.1(Continuity of Marking) |
- |
0 |
|
- |
8.2(Durability) |
- |
0 |
|
- |
9(Core Identification) |
- |
0 |
|
- |
4.1(Resistance) |
- |
0 |
|
- |
7.1.2.1, 7.2.3(Annealing) |
- |
0 |
|
- |
Table 3, (IS 10810 Part 53)(Test for vertical flame propagation on complete cable) |
- |
0 |
|
- |
Cl 5.7 & Annex D (D.1, D.2, D.3, D.4) of IS 17048:2018.(pH) |
- |
0 |
|
- |
Cl 5.7 & Annex D (D.1, D.2, D.3, D.4) of IS 17048:2018.(Conductivity) |
- |
0 |
|
- |
Cl 5.7 & Annex D (D.1, D.2, D.3, D.4) of IS 17048:2018.(HCl and HBr) |
- |
0 |
|
- |
Cl 5.7 & Annex D (D.1, D.2, D.3, D.4) of IS 17048:2018.(Presence of Fluorine / Fluorine Content (if required)) |
- |
0 |
|
- |
11.2.2(Spark Test) |
- |
0 |
|
- |
12(Packing and Marking) |
- |
0 |
|
- |
8.3(Legibility) |
- |
0 |
|
- |
|
Complete
|
|
16 Apr, 2026 |
- Included w.e.f. 28.03.2024 |
6 |
IS 398 : Part 6 (2021) |
Aluminium Conductors For Overhead Transmission Purposes Part 6: High conductivity aluminium alloy stranded conductors |
- |
-
|
180000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
16.2(Visual Examination) |
- |
500 |
|
- |
16.3, Table 4(Measurement of Lay Ratio / Direction of Lay) |
- |
2000 |
|
- |
16.3, Table 4(Measurement of Lay Ratio / Direction of Lay) |
- |
2000 |
|
- |
16.3, Table 4(Measurement of Lay Ratio / Direction of Lay) |
- |
2000 |
|
- |
16.3, Table 4(Measurement of Lay Ratio / Direction of Lay) |
- |
2000 |
|
- |
16.4, Table 2(Measurement of Diameter of Individual Aluminium Alloy Wires) |
- |
2000 |
|
- |
16.5, Table 2(Breaking Load Test - before stranding) |
- |
2500 |
|
- |
16.5, Table 2(Breaking Load Test - after stranding) |
- |
2500 |
|
- |
16.6, Table 1(Elongation Test - before stranding) |
- |
2500 |
|
- |
16.6, Table 1(Elongation Test - after stranding) |
- |
2500 |
|
- |
16.7, Table 2(Resistivity Test) |
- |
5000 |
|
- |
16.8(Wrapping Test) |
- |
2000 |
|
- |
11(Stranding) |
- |
500 |
|
- |
8(Freedom from defects) |
- |
500 |
|
- |
16.9, Table 3(Ultimate Tensile Strength on Stranded Conductor) |
- |
20000 |
|
- |
16.10, Table 3(d.c. Resistance Test on Stranded Conductor) |
- |
3000 |
|
- |
16.11(Stress-strain Test) |
- |
30000 |
|
- |
|
Complete
|
|
16 Apr, 2026 |
- Included w.e.f. 29.08.2023 |
7 |
IS 17505 : Part 1 (2021) |
Specification for Thermosetting Insulated Fire Survival Cables for Fixed Installation having Low Emission of Smoke and Corrosive Gases when Affected by Fire for Working Voltages upto and including 1100 Vac and 1500 Vdc |
- |
-
|
140000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Cl. 7.3, Table 1 to 5 of IS 8130:2013 & IS:10810 (Part 5)-1984(Conductor Resistance Test) |
- |
2000 |
|
- |
Cl. 7.1.2 of IS 8130 : 2013 & IS:10810 (Part 1)-1984(Annealing Test (for copper)) |
- |
2000 |
|
- |
Cl. 7.1.1 of IS 8130:2013 & IS:10810 (Part 4)-1984(Persulphate Test for tinned copper) |
- |
2000 |
|
- |
IS 191:2007 & IS 440(Copper purity test) |
- |
5000 |
|
- |
Cl. 11,14,16, Table 4 and Table 6 of IS 17505 & IS:10810 (Part 6)-1984(Test for overall dimensions and thickness of insulation and sheath) |
- |
2000 |
|
- |
Table 7 of IS 17505-1:2021, IS 3975:1999 & IS:10810 (Part 36)-1984(Diameter of armour Wire) |
- |
1000 |
|
- |
Table 7 of IS 17505-1:2021, IS 3975:1999 & IS:10810 (Part 37)-1984(Tensile strength and elongation at break) |
- |
2000 |
|
- |
Table 7 of IS 17505-1:2021, IS 3975:1999 & IS:10810 (Part 38)-1984(Torsion Test on galvanised steel wire for armouring) |
- |
3000 |
|
- |
Table 7 of IS 17505-1:2021, IS 3975:1999 & IS:10810 (Part 39)-1984(Winding Test for Formed Wires) |
- |
3000 |
|
- |
Table 7 of IS 17505-1:2021, IS 3975:1999 & IS:10810 (Part 40)-1984(Uniformity of Zinc coating on Round Steel Wires and Formed Steel Wires (Strips)) |
- |
3000 |
|
- |
Table 7 of IS 17505-1:2021, IS 3975:1999 & IS:10810 (Part 41)-1984(Mass of Zinc coating on Round Steel Wires and Formed Steel Wires (Strips)) |
- |
3000 |
|
- |
Table 7 of IS 17505-1:2021, IS 3975:1999 & IS:10810 (Part 42)-1984(Resistivity test) |
- |
2000 |
|
- |
Table 1 and Table 2 of IS 17505 -1: 2021, IS:10810 (Part 7)-1984 & IS:10810 (Part 11)-1984(Tensile Strength and elongation at break before and after ageing.) |
- |
2000 |
|
- |
Cl 18.2 of IS 17505-1:2021 & IS:10810 (Part 45)-1984(High voltage test) |
- |
3000 |
|
- |
Table 1 of IS 17505-1 :2021 & IS:10810 (Part 43)-1984(Insulation Resistance) |
- |
5000 |
|
- |
Cl. 18.6 of IS 17505-1:2021 & IS:10810 (Part 58)-1998(Oxygen index) |
- |
3500 |
|
- |
Cl. 18.7 of IS 17505-1:2021 & IS:10810 (Part 64)-2003(Temperature Index) |
- |
3500 |
|
- |
Table-1 & Table-2 of IS 17505-1:2021 & IS:10810 (Part 11)-1984(Ageing in air oven.) |
- |
5000 |
|
- |
Table-1 & Annex-F (F.1, F.2, F.3 F.4) of IS 17505-1 :2021(pH) |
- |
3500 |
|
- |
Table-1 & Annex-F (F.1, F.2, F.3 F.4) of IS 17505-1 :2021(Conductivity) |
- |
3500 |
|
- |
Table-1 & Annex-F (F.1, F.2, F.3 F.4) of IS 17505-1 :2021(HCl and HBr) |
- |
3500 |
|
- |
Table-1 & Annex-F (F.1, F.2, F.3 F.4) of IS 17505-1 :2021(Presence of Fluorine / Fluorine Content (if required)) |
- |
10000 |
|
- |
Table 1 of IS 17505-1: 2021 & IS:10810 (Part 21)-1984(Cold impact test) |
- |
3000 |
|
- |
Table 1 & 2 of IS 17505-1: 2021 & IS:10810 (Part 30)-1984(Hot set test) |
- |
5000 |
|
- |
Table 1 & 2 of IS 17505-1: 2021 & IS:10810 (Part 13)-1984(Ozone Resistance test) |
- |
15000 |
|
- |
Cl 18.5.1 of IS 17505-1 :2021 & IS:10810 (Part 61)-1988(Flame test on single cable) |
- |
3000 |
|
- |
Table 1 of IS 17505-1:2021 & IS:10810 (Part 12)-1984(Shrinkage test) |
- |
2000 |
|
- |
Cl 7 & Annex-F (F.1, F.2, F.3 F.4) of IS 17505-1 :2021(pH) |
- |
3500 |
|
- |
Cl 7 & Annex-F (F.1, F.2, F.3 F.4) of IS 17505-1 :2021(Conductivity) |
- |
3500 |
|
- |
Cl 7 & Annex-F (F.1, F.2, F.3 F.4) of IS 17505-1 :2021(HCl and HBr) |
- |
3500 |
|
- |
Cl 7 & Annex-F (F.1, F.2, F.3 F.4) of IS 17505-1 :2021(Presence of Fluorine / Fluorine Content (if required)) |
- |
10000 |
|
- |
Tabel 1 and 2 of IS 17505-1:2021 & IS:10810 (Part 7)-1984(Tensile strength and elongation at break.) |
- |
2000 |
|
- |
Tabel 1 and 2 of IS 17505-1:2021 & IS:10810 (Part 11)-1984(Ageing in air oven.) |
- |
5000 |
|
- |
Cl 18.6 of IS 17505-1: 2021 & IS:10810 (Part 58)-1998(Oxygen Index.) |
- |
3500 |
|
- |
Cl 18.8 of IS 17505-1:2021 & IS:10810 (Part 64)-2003(Temperature Index) |
- |
3500 |
|
- |
Table 1 & 2 of IS 17505-1: 2021 & IS:10810 (Part 13)-1984(Ozone resistance test) |
- |
15000 |
|
- |
Table 2 of IS 17505-1:2021 & IS:10810 (Part 15)-1984(Hot deformation) |
- |
3000 |
|
- |
Cl 7 & Annex-F (F.1, F.2, F.3 F.4) of IS 17505-1 :2021(pH) |
- |
3500 |
|
- |
Cl 7 & Annex-F (F.1, F.2, F.3 F.4) of IS 17505-1 :2021(Conductivity) |
- |
3500 |
|
- |
Cl 7 & Annex-F (F.1, F.2, F.3 F.4) of IS 17505-1 :2021(HCl and HBr) |
- |
3500 |
|
- |
Cl 7 & Annex-F (F.1, F.2, F.3 F.4) of IS 17505-1 :2021(Presence of Fluorine / Fluorine Content (if required)) |
- |
10000 |
|
- |
Table 1 of IS 17505-1:2021 & IS:10810 (Part 12)-1984(Shrinkage test) |
- |
2000 |
|
- |
Cl 18.2of IS 17505-1:2021 & IS:10810 (Part 45)-1984.(High Voltage test.) |
- |
3000 |
|
- |
Cl 18.5of IS 17505-1:2021 & IS:10810 (Part 53)-1984(Flammability Test) |
- |
3000 |
|
- |
Table-2 of IS 17505-1:2021 & IS:10810 (Part 20)-1984(Cold bend test) |
- |
3000 |
|
- |
Table-2 of IS 17505-1:2021 & IS:10810 (Part 21)-1984(Cold impact test) |
- |
3000 |
|
- |
Cl 18.5 of IS 17505-1:2021 & IS:10810 (Part 61)-1988(Flammability Test) |
- |
3000 |
|
- |
Cl 18.9 of IS 17505-1:2021(Water immersion test ( effect of water on sheath of cable)) |
- |
7000 |
|
- |
Cl 18.8 of IS 17505-1:2021& IS:10810 (Part 63)-1993(Smoke density test) |
- |
35000 |
|
- |
Cl. 3.5, 18.4 & Annex-E of IS 17505-1:2021(Circuit integrity test under fire) |
- |
50000 |
|
- |
Cl. 17.1 Table 9 (iv) e(Heat Shock) |
- |
2000 |
|
- |
Cl. 17.1 Table 9 (iv) h(Water absorption (Gravimetric)) |
- |
10000 |
|
- |
Cl. 17.1 Table 9 (vii) b(Flame test on bunched cable) |
- |
10000 |
|
- |
Cl. 17.1 Table 9 (ix)(Abrasion resistance test) |
- |
5000 |
|
- |
Cl. 7.3, Table 1 to 5 of IS 8130:2013 & IS:10810 (Part 5)-1984(Conductor Resistance Test) |
- |
2000 |
|
- |
Cl. 7.1.2 of IS 8130 : 2013 & IS:10810 (Part 1)-1984(Annealing Test (for copper)) |
- |
2000 |
|
- |
Cl. 7.1.1 of IS 8130:2013 & IS:10810 (Part 4)-1984(Persulphate Test for tinned copper) |
- |
2000 |
|
- |
IS 191:2007 & IS 440(Copper purity test) |
- |
5000 |
|
- |
Cl. 11,14,16, Table 4 and Table 6 of IS 17505 & IS:10810 (Part 6)-1984(Test for overall dimensions and thickness of insulation and sheath) |
- |
2000 |
|
- |
Table 7 of IS 17505-1:2021, IS 3975:1999 & IS:10810 (Part 36)-1984(Diameter of armour Wire) |
- |
1000 |
|
- |
Table 7 of IS 17505-1:2021, IS 3975:1999 & IS:10810 (Part 37)-1984(Tensile strength and elongation at break) |
- |
2000 |
|
- |
Table 7 of IS 17505-1:2021, IS 3975:1999 & IS:10810 (Part 38)-1984(Torsion Test on galvanised steel wire for armouring) |
- |
3000 |
|
- |
Table 7 of IS 17505-1:2021, IS 3975:1999 & IS:10810 (Part 39)-1984(Winding Test for Formed Wires) |
- |
3000 |
|
- |
Table 7 of IS 17505-1:2021, IS 3975:1999 & IS:10810 (Part 40)-1984(Uniformity of Zinc coating on Round Steel Wires and Formed Steel Wires (Strips)) |
- |
3000 |
|
- |
Table 7 of IS 17505-1:2021, IS 3975:1999 & IS:10810 (Part 41)-1984(Mass of Zinc coating on Round Steel Wires and Formed Steel Wires (Strips)) |
- |
3000 |
|
- |
Table 7 of IS 17505-1:2021, IS 3975:1999 & IS:10810 (Part 42)-1984(Resistivity test) |
- |
2000 |
|
- |
Table 1 and Table 2 of IS 17505 -1: 2021, IS:10810 (Part 7)-1984 & IS:10810 (Part 11)-1984(Tensile Strength and elongation at break before and after ageing.) |
- |
2000 |
|
- |
Cl 18.2 of IS 17505-1:2021 & IS:10810 (Part 45)-1984(High voltage test) |
- |
3000 |
|
- |
Table 1 of IS 17505-1 :2021 & IS:10810 (Part 43)-1984(Insulation Resistance) |
- |
5000 |
|
- |
Cl. 18.6 of IS 17505-1:2021 & IS:10810 (Part 58)-1998(Oxygen index) |
- |
3500 |
|
- |
Cl. 18.7 of IS 17505-1:2021 & IS:10810 (Part 64)-2003(Temperature Index) |
- |
3500 |
|
- |
Table-1 & Table-2 of IS 17505-1:2021 & IS:10810 (Part 11)-1984(Ageing in air oven.) |
- |
5000 |
|
- |
Table-1 & Annex-F (F.1, F.2, F.3 F.4) of IS 17505-1 :2021(pH) |
- |
3500 |
|
- |
Table-1 & Annex-F (F.1, F.2, F.3 F.4) of IS 17505-1 :2021(Conductivity) |
- |
3500 |
|
- |
Table-1 & Annex-F (F.1, F.2, F.3 F.4) of IS 17505-1 :2021(HCl and HBr) |
- |
3500 |
|
- |
Table-1 & Annex-F (F.1, F.2, F.3 F.4) of IS 17505-1 :2021(Presence of Fluorine / Fluorine Content (if required)) |
- |
10000 |
|
- |
Table 1 of IS 17505-1: 2021 & IS:10810 (Part 21)-1984(Cold impact test) |
- |
3000 |
|
- |
Table 1 & 2 of IS 17505-1: 2021 & IS:10810 (Part 30)-1984(Hot set test) |
- |
5000 |
|
- |
Table 1 & 2 of IS 17505-1: 2021 & IS:10810 (Part 13)-1984(Ozone Resistance test) |
- |
15000 |
|
- |
Cl 18.5.1 of IS 17505-1 :2021 & IS:10810 (Part 61)-1988(Flame test on single cable) |
- |
3000 |
|
- |
Table 1 of IS 17505-1:2021 & IS:10810 (Part 12)-1984(Shrinkage test) |
- |
2000 |
|
- |
Cl 7 & Annex-F (F.1, F.2, F.3 F.4) of IS 17505-1 :2021(pH) |
- |
3500 |
|
- |
Cl 7 & Annex-F (F.1, F.2, F.3 F.4) of IS 17505-1 :2021(Conductivity) |
- |
3500 |
|
- |
Cl 7 & Annex-F (F.1, F.2, F.3 F.4) of IS 17505-1 :2021(HCl and HBr) |
- |
3500 |
|
- |
Cl 7 & Annex-F (F.1, F.2, F.3 F.4) of IS 17505-1 :2021(Presence of Fluorine / Fluorine Content (if required)) |
- |
10000 |
|
- |
Tabel 1 and 2 of IS 17505-1:2021 & IS:10810 (Part 7)-1984(Tensile strength and elongation at break.) |
- |
2000 |
|
- |
Tabel 1 and 2 of IS 17505-1:2021 & IS:10810 (Part 11)-1984(Ageing in air oven.) |
- |
5000 |
|
- |
Cl 18.6 of IS 17505-1: 2021 & IS:10810 (Part 58)-1998(Oxygen Index.) |
- |
3500 |
|
- |
Cl 18.8 of IS 17505-1:2021 & IS:10810 (Part 64)-2003(Temperature Index) |
- |
3500 |
|
- |
Table 1 & 2 of IS 17505-1: 2021 & IS:10810 (Part 13)-1984(Ozone resistance test) |
- |
15000 |
|
- |
Table 2 of IS 17505-1:2021 & IS:10810 (Part 15)-1984(Hot deformation) |
- |
5000 |
|
- |
Cl 7 & Annex-F (F.1, F.2, F.3 F.4) of IS 17505-1 :2021(pH) |
- |
3500 |
|
- |
Cl 7 & Annex-F (F.1, F.2, F.3 F.4) of IS 17505-1 :2021(Conductivity) |
- |
3500 |
|
- |
Cl 7 & Annex-F (F.1, F.2, F.3 F.4) of IS 17505-1 :2021(HCl and HBr) |
- |
3500 |
|
- |
Cl 7 & Annex-F (F.1, F.2, F.3 F.4) of IS 17505-1 :2021(Presence of Fluorine / Fluorine Content (if required)) |
- |
10000 |
|
- |
Table 1 of IS 17505-1:2021 & IS:10810 (Part 12)-1984(Shrinkage test) |
- |
2000 |
|
- |
Cl 18.2of IS 17505-1:2021 & IS:10810 (Part 45)-1984.(High Voltage test.) |
- |
3000 |
|
- |
Cl 18.5of IS 17505-1:2021 & IS:10810 (Part 53)-1984(Flammability Test) |
- |
3000 |
|
- |
Table-2 of IS 17505-1:2021 & IS:10810 (Part 20)-1984(Cold bend test) |
- |
3000 |
|
- |
Table-2 of IS 17505-1:2021 & IS:10810 (Part 21)-1984(Cold impact test) |
- |
3000 |
|
- |
Cl 18.5 of IS 17505-1:2021 & IS:10810 (Part 61)-1988(Flammability Test) |
- |
3000 |
|
- |
Cl 18.9 of IS 17505-1:2021(Water immersion test ( effect of water on sheath of cable)) |
- |
7000 |
|
- |
Cl 18.8 of IS 17505-1:2021& IS:10810 (Part 63)-1993(Smoke density test) |
- |
35000 |
|
- |
Cl. 3.5, 18.4 & Annex-E of IS 17505-1:2021(Circuit integrity test under fire) |
- |
50000 |
|
- |
Cl. 17.1 Table 9 (iv) e(Heat Shock) |
- |
2000 |
|
- |
Cl. 17.1 Table 9 (iv) h(Water absorption (Gravimetric)) |
- |
10000 |
|
- |
Cl. 17.1 Table 9 (vii) b(Flame test on bunched cable) |
- |
10000 |
|
- |
Cl. 17.1 Table 9 (ix)(Abrasion resistance test) |
- |
5000 |
|
- |
Cl. 7.3, Table 1 to 5 of IS 8130:2013 & IS:10810 (Part 5)-1984(Conductor Resistance Test) |
- |
- |
|
- |
Cl. 7.1.2 of IS 8130 : 2013 & IS:10810 (Part 1)-1984(Annealing Test (for copper)) |
- |
- |
|
- |
Cl. 7.1.1 of IS 8130:2013 & IS:10810 (Part 4)-1984(Persulphate Test for tinned copper) |
- |
- |
|
- |
IS 191:2007 & IS 440(Copper purity test) |
- |
- |
|
- |
Cl. 11,14,16, Table 4 and Table 6 of IS 17505 & IS:10810 (Part 6)-1984(Test for overall dimensions and thickness of insulation and sheath) |
- |
- |
|
- |
Table 7 of IS 17505-1:2021, IS 3975:1999 & IS:10810 (Part 36)-1984(Diameter of armour Wire) |
- |
- |
|
- |
Table 7 of IS 17505-1:2021, IS 3975:1999 & IS:10810 (Part 37)-1984(Tensile strength and elongation at break) |
- |
- |
|
- |
Table 7 of IS 17505-1:2021, IS 3975:1999 & IS:10810 (Part 38)-1984(Torsion Test on galvanised steel wire for armouring) |
- |
- |
|
- |
Table 7 of IS 17505-1:2021, IS 3975:1999 & IS:10810 (Part 39)-1984(Winding Test for Formed Wires) |
- |
- |
|
- |
Table 7 of IS 17505-1:2021, IS 3975:1999 & IS:10810 (Part 40)-1984(Uniformity of Zinc coating on Round Steel Wires and Formed Steel Wires (Strips)) |
- |
- |
|
- |
Table 7 of IS 17505-1:2021, IS 3975:1999 & IS:10810 (Part 41)-1984(Mass of Zinc coating on Round Steel Wires and Formed Steel Wires (Strips)) |
- |
- |
|
- |
Table 7 of IS 17505-1:2021, IS 3975:1999 & IS:10810 (Part 42)-1984(Resistivity test) |
- |
- |
|
- |
Table 1 and Table 2 of IS 17505 -1: 2021, IS:10810 (Part 7)-1984 & IS:10810 (Part 11)-1984(Tensile Strength and elongation at break before and after ageing.) |
- |
- |
|
- |
Cl 18.2 of IS 17505-1:2021 & IS:10810 (Part 45)-1984(High voltage test) |
- |
- |
|
- |
Table 1 of IS 17505-1 :2021 & IS:10810 (Part 43)-1984(Insulation Resistance) |
- |
- |
|
- |
Cl. 18.6 of IS 17505-1:2021 & IS:10810 (Part 58)-1998(Oxygen index) |
- |
- |
|
- |
Cl. 18.7 of IS 17505-1:2021 & IS:10810 (Part 64)-2003(Temperature Index) |
- |
- |
|
- |
Table-1 & Table-2 of IS 17505-1:2021 & IS:10810 (Part 11)-1984(Ageing in air oven.) |
- |
- |
|
- |
Table-1 & Annex-F (F.1, F.2, F.3 F.4) of IS 17505-1 :2021(pH) |
- |
- |
|
- |
Table-1 & Annex-F (F.1, F.2, F.3 F.4) of IS 17505-1 :2021(Conductivity) |
- |
- |
|
- |
Table-1 & Annex-F (F.1, F.2, F.3 F.4) of IS 17505-1 :2021(HCl and HBr) |
- |
- |
|
- |
Table-1 & Annex-F (F.1, F.2, F.3 F.4) of IS 17505-1 :2021(Presence of Fluorine / Fluorine Content (if required)) |
- |
- |
|
- |
Table 1 of IS 17505-1: 2021 & IS:10810 (Part 21)-1984(Cold impact test) |
- |
- |
|
- |
Table 1 & 2 of IS 17505-1: 2021 & IS:10810 (Part 30)-1984(Hot set test) |
- |
- |
|
- |
Table 1 & 2 of IS 17505-1: 2021 & IS:10810 (Part 13)-1984(Ozone Resistance test) |
- |
- |
|
- |
Cl 18.5.1 of IS 17505-1 :2021 & IS:10810 (Part 61)-1988(Flame test on single cable) |
- |
- |
|
- |
Table 1 of IS 17505-1:2021 & IS:10810 (Part 12)-1984(Shrinkage test) |
- |
- |
|
- |
Cl 7 & Annex-F (F.1, F.2, F.3 F.4) of IS 17505-1 :2021(pH) |
- |
- |
|
- |
Cl 7 & Annex-F (F.1, F.2, F.3 F.4) of IS 17505-1 :2021(Conductivity) |
- |
- |
|
- |
Cl 7 & Annex-F (F.1, F.2, F.3 F.4) of IS 17505-1 :2021(HCl and HBr) |
- |
- |
|
- |
Cl 7 & Annex-F (F.1, F.2, F.3 F.4) of IS 17505-1 :2021(Presence of Fluorine / Fluorine Content (if required)) |
- |
- |
|
- |
Tabel 1 and 2 of IS 17505-1:2021 & IS:10810 (Part 7)-1984(Tensile strength and elongation at break.) |
- |
- |
|
- |
Tabel 1 and 2 of IS 17505-1:2021 & IS:10810 (Part 11)-1984(Ageing in air oven.) |
- |
- |
|
- |
Cl 18.6 of IS 17505-1: 2021 & IS:10810 (Part 58)-1998(Oxygen Index.) |
- |
- |
|
- |
Cl 18.8 of IS 17505-1:2021 & IS:10810 (Part 64)-2003(Temperature Index) |
- |
- |
|
- |
Table 1 & 2 of IS 17505-1: 2021 & IS:10810 (Part 13)-1984(Ozone resistance test) |
- |
- |
|
- |
Table 2 of IS 17505-1:2021 & IS:10810 (Part 15)-1984(Hot deformation) |
- |
- |
|
- |
Cl 7 & Annex-F (F.1, F.2, F.3 F.4) of IS 17505-1 :2021(pH) |
- |
- |
|
- |
Cl 7 & Annex-F (F.1, F.2, F.3 F.4) of IS 17505-1 :2021(Conductivity) |
- |
- |
|
- |
Cl 7 & Annex-F (F.1, F.2, F.3 F.4) of IS 17505-1 :2021(HCl and HBr) |
- |
- |
|
- |
Cl 7 & Annex-F (F.1, F.2, F.3 F.4) of IS 17505-1 :2021(Presence of Fluorine / Fluorine Content (if required)) |
- |
- |
|
- |
Table 1 of IS 17505-1:2021 & IS:10810 (Part 12)-1984(Shrinkage test) |
- |
- |
|
- |
Cl 18.2of IS 17505-1:2021 & IS:10810 (Part 45)-1984.(High Voltage test.) |
- |
- |
|
- |
Cl 18.5of IS 17505-1:2021 & IS:10810 (Part 53)-1984(Flammability Test) |
- |
- |
|
- |
Table-2 of IS 17505-1:2021 & IS:10810 (Part 20)-1984(Cold bend test) |
- |
- |
|
- |
Table-2 of IS 17505-1:2021 & IS:10810 (Part 21)-1984(Cold impact test) |
- |
- |
|
- |
Cl 18.5 of IS 17505-1:2021 & IS:10810 (Part 61)-1988(Flammability Test) |
- |
- |
|
- |
Cl 18.9 of IS 17505-1:2021(Water immersion test ( effect of water on sheath of cable)) |
- |
- |
|
- |
Cl 18.8 of IS 17505-1:2021& IS:10810 (Part 63)-1993(Smoke density test) |
- |
- |
|
- |
Cl. 3.5, 18.4 & Annex-E of IS 17505-1:2021(Circuit integrity test under fire) |
- |
- |
|
- |
Cl. 17.1 Table 9 (iv) e(Heat Shock) |
- |
- |
|
- |
Cl. 17.1 Table 9 (iv) h(Water absorption (Gravimetric)) |
- |
- |
|
- |
Cl. 17.1 Table 9 (vii) b(Flame test on bunched cable) |
- |
- |
|
- |
Cl. 17.1 Table 9 (ix)(Abrasion resistance test) |
- |
- |
|
- |
|
Complete
|
|
16 Apr, 2026 |
- Included w.e.f. 29.08.2023 |
8 |
IS 15652 (2006) |
Insulating mats for electrical purposes - Specification |
- |
-
|
50000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
9(Marking (As per Cl.9.1 of IS 15652 : 2006)) |
- |
1000 |
|
- |
9(Marking (As per Cl.9.1 of IS 15652 : 2006)) |
- |
1000 |
|
- |
9(Marking (As per Cl.9.1 of IS 15652 : 2006)) |
- |
1000 |
|
- |
9(Marking (As per Cl.9.1 of IS 15652 : 2006)) |
- |
1000 |
|
- |
9(Marking (As per Cl.9.1 of IS 15652 : 2006)) |
- |
1000 |
|
- |
9(Marking (As per Cl.9.2 of IS 15652 : 2006)) |
- |
1000 |
|
- |
10.a)(Packing) |
- |
1000 |
|
- |
10.b)(Packing) |
- |
1000 |
|
- |
10.c)(Packing) |
- |
1000 |
|
- |
4(Classification and Designation (As per Cl.4.1 and Table-1 of IS 15652 : 2006)) |
- |
1000 |
|
- |
4(Classification and Designation (As per Cl.4.1 and Table-1 of IS 15652 : 2006)) |
- |
1000 |
|
- |
4(Classification and Designation (As per Cl.4.1 and Table-1 of IS 15652 : 2006)) |
- |
1000 |
|
- |
4(Classification and Designation (As per Cl.4.2 of IS 15652 : 2006)) |
- |
1000 |
|
- |
4(Classification and Designation (As per Cl.4.2 of IS 15652 : 2006)) |
- |
1000 |
|
- |
4(Classification and Designation (As per Cl.4.2 of IS 15652 : 2006)) |
- |
1000 |
|
- |
4(Classification and Designation (As per Cl.4.2 of IS 15652 : 2006)) |
- |
1000 |
|
- |
5(Composition (As per Cl. 5.1 of IS 15652 : 2006)) |
- |
1000 |
|
- |
5(Composition (As per Cl. 5.2 of IS 15652 : 2006)) |
- |
1000 |
|
- |
6(Shape Requirements and Dimension (As per Cl.6.1 & 6.2 of IS 15652 : 2006)) |
- |
2000 |
|
- |
6(Shape Requirements and Dimension (As per Cl.6.1 & 6.2 of IS 15652 : 2006)) |
- |
2000 |
|
- |
6(Thickness [mm] (As per Cl. 6.3 and Table-2 of IS 15652 : 2006)) |
- |
2000 |
|
- |
6(Thickness [mm] (As per Cl. 6.3 and Table-2 of IS 15652 : 2006)) |
- |
2000 |
|
- |
6(Thickness [mm] (As per Cl. 6.3 and Table-2 of IS 15652 : 2006)) |
- |
2000 |
|
- |
6(Colour (As per Cl. 6.4 of IS 15652 : 2006)) |
- |
1000 |
|
- |
7(Workmanship & Finish (As per Cl. 7.1 of IS 15652 : 2006)) |
- |
1000 |
|
- |
8(Physical properties (As per Cl.8.1 and Table - 3 of IS 15652 : 2006)) |
- |
5000 |
|
- |
8(Physical properties (As per Cl.8.1 and Table - 3 of IS 15652 : 2006)) |
- |
5000 |
|
- |
8(Physical properties (As per Cl.8.3 of IS 15652 : 2006)) |
- |
5000 |
|
- |
8(Physical properties (As per Cl.8.3 of IS 15652 : 2006)) |
- |
5000 |
|
- |
8(Physical properties (As per Cl.8.5 of IS 15652 : 2006)) |
- |
5000 |
|
- |
8(Physical properties (As per Cl.8.5 of IS 15652 : 2006)) |
- |
5000 |
|
- |
8(Physical properties (As per Cl.8.5 of IS 15652 : 2006)) |
- |
5000 |
|
- |
8(Physical properties (As per Cl.8.5 of IS 15652 : 2006)) |
- |
5000 |
|
- |
8(Physical properties (As per Cl.8.5 of IS 15652 : 2006)) |
- |
5000 |
|
- |
8(Physical properties (As per Cl.8.5 of IS 15652 : 2006)) |
- |
5000 |
|
- |
8(Physical properties (As per Cl.8.5 of IS 15652 : 2006)) |
- |
5000 |
|
- |
8(Di-electric Properties (As per Cl.8.2.1 and C-3.1 of IS 15652 : 2006)) |
- |
5000 |
|
- |
8(Di-electric Properties (As per Cl.8.2.2 and C-3.2 of IS 15652 : 2006)) |
- |
5000 |
|
- |
8(Di-electric Properties (As per Cl.8.2.3 and C-3.3 of IS 15652 : 2006)) |
- |
5000 |
|
- |
8(Di-electric Properties (As per Cl.8.2.3 and Table-4 of IS 15652 : 2006)) |
- |
5000 |
|
- |
8(Di-electric Properties (As per Cl.8.2.3 and Table-4 of IS 15652 : 2006)) |
- |
5000 |
|
- |
8(Di-electric Properties (Cl.8.2), A.C. Proof Voltage (Cl.8.2.4), C-3.4 and Table-5 of IS 15652 : 2006)) |
- |
5000 |
|
- |
8(A.C. Proof Voltage (Cl.8.2.4), C-3.4 and Table-5 of IS 15652 : 2006)) |
- |
5000 |
|
- |
8(A.C. Proof Voltage (Cl.8.2.4), C-3.4 and Table-5 of IS 15652 : 2006)) |
- |
5000 |
|
- |
8(Thermal Properties (Cl..8.4)) |
- |
5000 |
|
- |
8(Thermal Properties (Cl..8.4)) |
- |
5000 |
|
- |
8(Extreme Low Temperature (Cl.8.6)) |
- |
5000 |
|
- |
|
Complete
|
|
16 Apr, 2026 |
- - |
9 |
IS 191 (2007) |
Copper - Specification (Fourth Revision) |
- |
-
|
50000 View breakup
For Cu-CATH-1 grade Rs. 24,000
For Cu-CATH-2 grade Rs. 24,000/-
For Cu-ETP grade 6,000/-
For Cu-FRHC grade 6,000/-
For Cu-FRTP-1 grade Rs. 20,000/-
For Cu-FRTP-2 grade Rs. 20,000/-
For Cu-DHP grade Rs. 22000/-
For Cu-ATP grade Rs. 20,000/-
For Cu-DPA grade Rs. 22,000/-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
7.1 - Table 4(Copper + Silver(By difference)-IS440) |
- |
2000 |
|
- |
7.1 - Table 4(Bismuth-IS 440) |
- |
2000 |
|
- |
7.1 - Table 4(Lead IS 440) |
- |
2000 |
|
- |
7.1 - Table 4(Oxygen IS 440) |
- |
2000 |
|
- |
4-Table 1(GRADES/DESIGNATIONS) |
- |
500 |
|
- |
5.1- Table 2(L) |
- |
500 |
|
- |
5.1- Table 2(L1) |
- |
500 |
|
- |
5.1- Table 2(h) |
- |
500 |
|
- |
5.1- Table 2(h1) |
- |
500 |
|
- |
5.1- Table 2(b) |
- |
500 |
|
- |
5.1- Table 2(b1) |
- |
500 |
|
- |
5.1- Table 2(R) |
- |
500 |
|
- |
5.1- Table 2(R1) |
- |
500 |
|
- |
5.1- Table 2(R2 ) |
- |
500 |
|
- |
5.1- Table 2(α ) |
- |
500 |
|
- |
5.1- Table 2( β ) |
- |
500 |
|
- |
5.1- Table 2(γ) |
- |
500 |
|
- |
5.2(Billets) |
- |
500 |
|
- |
5.4-Table 3 (For Billets)(Mass) |
- |
1000 |
|
- |
5.2-Table 3 (For Billets)(Diameter) |
- |
1000 |
|
- |
5.2-Table 3 (For Billets)(Length) |
- |
500 |
|
- |
5.2-Table 3 (For Billets)(Deviation from straightness per 1000 mm length) |
- |
500 |
|
- |
5.4-Table 3 (Vertically continuously cast wire bars)(Mass) |
- |
500 |
|
- |
5.3-Table 3 (Vertically continuously cast wire bars)(Width) |
- |
500 |
|
- |
5.3-Table 3 (Vertically continuously cast wire bars)(thickness ) |
- |
500 |
|
- |
5.3-Table 3 (Vertically continuously cast wire bars)(Other dimention) |
- |
500 |
|
- |
5.4-Table 3 (Ingots)(Mass) |
- |
500 |
|
- |
5.4-Table 3 (Cast cakes)(Mass) |
- |
500 |
|
- |
5.3-Table 3 (Vertically static cast wire bars)(Width) |
- |
500 |
|
- |
5.3-Table 3 (Cast cakes)(thickness ) |
- |
500 |
|
- |
5.3-Table 3 (Cast cakes)(Deviation from straightness per 1000 mm length) |
- |
500 |
|
- |
7.1 - Table 4(Phosphorus- IS 440) |
- |
2000 |
|
- |
7.1 - Table 4(Arsenic- IS440) |
- |
2000 |
|
- |
7.1 - Table 4(Antimony-IS440) |
- |
2000 |
|
- |
7.1 - Table 4(Iron IS 440) |
- |
2000 |
|
- |
7.1 - Table 4(Nickel IS 440) |
- |
2000 |
|
- |
7.1 - Table 4(Selenium - IS 440) |
- |
2000 |
|
- |
7.1 - Table 4(Sulphur- IS 440) |
- |
2000 |
|
- |
7.1 - Table 4(Tellurium- IS 440) |
- |
2000 |
|
- |
7.1 - Table 4(Tin - IS 440) |
- |
2000 |
|
- |
7.1 - Table 4(Znic-IS 440) |
- |
2000 |
|
- |
7.1 - Table 4(Total Impurities- IS 440) |
- |
2000 |
|
- |
8.1(FREEDOM FROM DEFECTS) |
- |
500 |
|
- |
8.2(FREEDOM FROM DEFECTS) |
- |
500 |
|
- |
9.1- Table 5(Mass Resistivity- IS 3635) |
- |
2000 |
|
- |
13(Marking) |
- |
500 |
|
- |
13(Marking) |
- |
500 |
|
- |
13(Marking) |
- |
500 |
|
- |
7.1 - Table 4(Silver- IS 440) |
- |
2000 |
|
- |
7.1 - Table 4(Copper (any Silver present to be counted as copper)-IS440) |
- |
2000 |
|
- |
10(HYDROGEN EMBRITTLEMENT TEST- IS 191) |
- |
2000 |
|
- |
9.1 , 9.2 & 10(Resistivity & HYDROGEN EMBRITTLEMENT TEST) |
- |
2000 |
|
- |
9.1 , 9.2 & 10(Resistivity & HYDROGEN EMBRITTLEMENT TEST) |
- |
2000 |
|
- |
|
Complete
|
|
16 Apr, 2026 |
- - |
10 |
IS 16246 (2015) |
Elastomer insulated cables with limited circuit integrity when affected by fire - Specification |
- |
-
|
100000 View breakup
Rs. 100000/- for all sizes and types of
cables
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Cl.4.1( Cables for Fixed Installation) |
- |
1000 |
|
- |
Cl.5( INSULATION) |
- |
1000 |
|
- |
Cl. 6.1( Glass Tape) |
- |
1000 |
|
- |
Cl 6.2( Polyethylene Teraphthalate (PETP) or Polypropylene base Tape) |
- |
1000 |
|
- |
Cl 6.4( Fire Barrier Tape) |
- |
1000 |
|
- |
Cl 7(CENTRE AND FILLERS) |
- |
1000 |
|
- |
Cl 7(CENTRE AND FILLERS) |
- |
1000 |
|
- |
Cl 7(CENTRE AND FILLERS) |
- |
1000 |
|
- |
Cl 7(CENTRE AND FILLERS) |
- |
1000 |
|
- |
Cl 8( ARMOUR) |
- |
1000 |
|
- |
Cl 9.1( Inner Sheath) |
- |
1000 |
|
- |
Cl 9.2( Outer Sheath) |
- |
1000 |
|
- |
Cl 10.1( CONDUCTORS) |
- |
1000 |
|
- |
Cl 10.2( CONDUCTORS) |
- |
1000 |
|
- |
Cl 11.1( INSULATION) |
- |
1000 |
|
- |
Cl 11.2(Thickness of Insulation IS 10810 : Part 6) |
- |
2000 |
|
- |
Cl 12( CORE IDENTIFICATION) |
- |
1000 |
|
- |
Cl 13( LAYING UP OF CORES) |
- |
1000 |
|
- |
Cl 14.2( Thickness of Inner Sheath IS 10810 : Part 6) |
- |
2000 |
|
- |
Cl 15.1( ARMOURING) |
- |
1000 |
|
- |
Cl 15.3.1( Type of Armour) |
- |
1000 |
|
- |
Cl 15.3.2( Type of Armour) |
- |
1000 |
|
- |
Cl 15.3.3( ARMOURING) |
- |
1000 |
|
- |
Cl 15.3.3( ARMOURING) |
- |
1000 |
|
- |
Cl 15.4.1( ARMOURING) |
- |
1000 |
|
- |
Cl 15.4.2( ARMOURING) |
- |
1000 |
|
- |
Cl 15.4.2( ARMOURING) |
- |
1000 |
|
- |
Cl 15.4.2( ARMOURING) |
- |
1000 |
|
- |
Cl 15.4.2( ARMOURING) |
- |
1000 |
|
- |
Cl 15.4.2( ARMOURING) |
- |
1000 |
|
- |
Cl 16.2( OUTER SHEATH) |
- |
1000 |
|
- |
Cl 16.3( Thickness of Outer Sheath - Avg IS 10810 : Part 6) |
- |
2000 |
|
- |
Cl 16.3( Thickness of Outer Sheath - Minimum IS 10810 : Part 6) |
- |
2000 |
|
- |
Cl 17.2(Annealing test (for copper) IS 10810 : Part 1) |
- |
2000 |
|
- |
Cl 17.2(Conductor resistance test IS 10810 : Part 5) |
- |
2000 |
|
- |
Cl 17.1(Persulphate test (tinned copper conductor) IS 10810 : Part 4) |
- |
5000 |
|
- |
Cl 17.2(Tensile strength before ageing on insulation IS 10810 : Part 7) |
- |
2000 |
|
- |
Cl 17.2(elongation at break before ageing on insulation IS 10810 : Part 7) |
- |
2000 |
|
- |
Cl 17.2(Tensile strength after Ageing in air bomb IS 10810 : Part 56) |
- |
5000 |
|
- |
Cl 17.2(Elongation after Ageing in air bomb IS 10810 : Part 56) |
- |
5000 |
|
- |
Cl 17.2(Tensile strength variation) |
- |
5000 |
|
- |
Cl 17.2(Elongation Variation) |
- |
5000 |
|
- |
Cl 17.2(Hot set elongation on insulation IS 10810 : Part 30) |
- |
5000 |
|
- |
Cl 17.1(Permanent elongation (set) test on sheath IS 10810 : Part 30) |
- |
5000 |
|
- |
Cl 17.1(Oxygen index test on sheath IS 10810 : Part 58) |
- |
5000 |
|
- |
Cl 17.1(Temperature index test on sheath IS 10810 : Part 64) |
- |
5000 |
|
- |
Cl 17.1(Acid gas generation on sheath IS 10810 : Part 39) |
- |
5000 |
|
- |
Cl 17.2(Insulation resistance test IS 10810 : Part 43) |
- |
5000 |
|
- |
Cl 17.1(Water absorption test (for insulation) IS 10810 : Part 28) |
- |
10000 |
|
- |
Cl 18.2(High Voltage Test IS 10810 : Part 45) |
- |
2000 |
|
- |
Cl 18.2(High Voltage Test IS 10810 : Part 45) |
- |
2000 |
|
- |
Cl 18.3 Annex B of IS 16246( Circuit Integrity Test Under Fire Condition) |
- |
25000 |
|
- |
Cl 18.3 Annex B of IS 16246( Circuit Integrity Test Under Fire Condition) |
- |
25000 |
|
- |
Cl 18.4.1( Flame Retardence Test on Single Cable IS 10810 : Part 61) |
- |
2000 |
|
- |
Cl 18.4.2(Flame Retardence Test on Bunched Cables IS 10810 : Part 63) |
- |
20000 |
|
- |
Cl 19.1( Manufacturer’s Identification) |
- |
1000 |
|
- |
Cl 19.2( Voltage Identification) |
- |
1000 |
|
- |
Cl 19.3( Cable Identification) |
- |
1000 |
|
- |
Cl 19.4( Cable Code) |
- |
1000 |
|
- |
Cl 17.2(Permanent elongation (set) on insulation IS 10810 : Part 30) |
- |
5000 |
|
- |
Cl 17.1(Tensile strength before ageing on sheath IS 10810 : Part 7) |
- |
2000 |
|
- |
Cl 17.1(elongation at break before ageing on sheath IS 10810 : Part 7) |
- |
2000 |
|
- |
|
Complete
|
|
16 Apr, 2026 |
- - |
11 |
IS 17048 (2018) |
Halogen free flame retardant (HFFR) cables for working voltages up to and including 1 100 Volts - Specification |
- |
-
|
93000 View breakup
Single core Halogen Free Flame
Retardant (HFFR) Insulated (unsheathed)
Cables Rs. 93,000/- for Category-01 02,
Rs. 85,000/- for Category-03 & 04.
Single-core Halogen Free Flame
Retardant (HFFR) Insulated & Sheathed
Cables Rs. 1,60,000/- for Category-01 &
02, Rs. 1,52,000/- for Category-03 & 04
Multi core Halogen Free Flame Retardant
(HFFR) Insulated & Sheathed Cables :
Rs. 1,85,800/- (up to 4 cores) Rs.
1,91,000/- (above 4 cores and up to 12
Cores cable) Rs. 1,97,000/-( above 12
cores and up to 25 Cores cable) for
Category-01 & 02 Rs. 1,79,300/- (up to 4
cores) Rs. 1,84,500/-( above 4 cores and
up to 12 Cores cable) Rs. 1,90,500/-(
above 12 cores and up to 25 Cores cable)
for Category-03 & 04
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
4.1.1 a) (Conductor : Material ) |
- |
1000 |
|
- |
4.1.1 b) (Material : Seperator tape ) |
- |
1000 |
|
- |
4.1.1 d) , 11.1, 12.1, 13.1,14.1(Class of conductor ) |
- |
1000 |
|
- |
4.1.1 e) (Shape of conductor ) |
- |
1000 |
|
- |
4.1.1 f) (Nominal size of conductor ) |
- |
1000 |
|
- |
4.2.1, 11.2, 12.2, 13.2, 14.2(Insulation : Material ) |
- |
1000 |
|
- |
4.2.2, 11.2, 12.2, 13.2, 14.2(Insulation : Application ) |
- |
1000 |
|
- |
4.2.3,11.2, 12.2, 13.2(Thickness of insulation - Avearge : IS 10810 ( Part 6 )) |
- |
2000 |
|
- |
4.2.3, 11.2, 12.2, 13.2, 14.2(Thickness of insulation - miniumum : IS 10810 ( Part 6 )) |
- |
2000 |
|
- |
4.2.4(Insulation : Tensile stregth ( Before ageing)-IS 10810 (Part 7) ) |
- |
2000 |
|
- |
4.2.4(Insulation : Elongation ( Before ageing) -IS 10810 (Part 7)) |
- |
2000 |
|
- |
4.2.4(Insulation : Tensile stregth ( After ageing) - IS 10810 (Part 7) ) |
- |
5000 |
|
- |
4.2.5(Insulation : Tensile stregth variation ( After ageing) - IS 10810 (Part 7) ) |
- |
5000 |
|
- |
4.2.4(Insulation : Elongation (after ageing) - IS 10810 (Part 7) ) |
- |
5000 |
|
- |
4.2.5(Insulation : Elongation variation (after ageing) - IS 10810 (Part 7) ) |
- |
5000 |
|
- |
4.3(Fillers) |
- |
1000 |
|
- |
4.4(Binder Tape) |
- |
1000 |
|
- |
4.5.1,13.4, 14.4(Sheath : Compound ) |
- |
1000 |
|
- |
4.5.2, 13.4, 14.4(Sheath : Application) |
- |
1000 |
|
- |
4.5.3,13.4, 14.4(Thickness of sheath - Average : IS 10810 (Part 6)) |
- |
2000 |
|
- |
4.5.3,13.4, 14.4(Thickness of sheath - Minimum : IS 10810 (Part 6)) |
- |
2000 |
|
- |
4.5.4, 13.4(Sheath : Tensile stregth ( Before ageing)-IS 10810 (Part 7) ) |
- |
2000 |
|
- |
4.5.4,13.4(Sheath : Elongation ( Before ageing) -IS 10810 (Part 7)) |
- |
2000 |
|
- |
4.5.4, 13.4, 14.4(Sheath : Elongation (after ageing) - IS 10810 (Part 7) ) |
- |
5000 |
|
- |
4.5.5, 13.4, 14.4(Sheath : Tensile stregth variation ( After ageing) - IS 10810 (Part 7) ) |
- |
5000 |
|
- |
4.5.5, 13.4,14.4(Sheath : Elongation variation (after ageing) - IS 10810 (Part 7) ) |
- |
5000 |
|
- |
4.5.5, 11.3, 12.3, 13.6, 14.6(Overall Dimensions) |
- |
2000 |
|
- |
4.5.5.1, 11.3, 12.3,13.5, 14.5(Ovality) |
- |
2000 |
|
- |
4.5.6, 13.4(Colour of Sheath) |
- |
1000 |
|
- |
5.1(High Voltage Test (at Room Temperature)) |
- |
2000 |
|
- |
5.3(Flammability Test- IS 10810 (Part 53).) |
- |
2000 |
|
- |
5.4(Oxygen Index Test- IS 10810 (Part 58)) |
- |
5000 |
|
- |
5.5(Temperature Index-IS 10810 (Part 64).) |
- |
5000 |
|
- |
5.6(Smoke Density-IS 10810 (Part 63).) |
- |
40000 |
|
- |
5.7(Assessment of Halogen- Table 1 of Annex D) |
- |
10000 |
|
- |
5.1(Persulphate Test- IS 10810 (Part 4).) |
- |
5000 |
|
- |
5.11(Flame Retardant Test- IS 10810 (Part 61),) |
- |
2000 |
|
- |
5.12(Hot Set Test- IS 10810 (Part 30).) |
- |
5000 |
|
- |
5.12(Permanent Set - IS 10810 (Part 30).) |
- |
5000 |
|
- |
5.13(Water Immersion Test (Effect of Water on Sheath) : Tensile strength -IS 10810 (Part 7).) |
- |
5000 |
|
- |
5.13(Water Immersion Test (Effect of Water on Sheath) : Elogation -IS 10810 (Part 7).) |
- |
5000 |
|
- |
5.14(Ozone Resistance Test -IS 10810 (Part 13 )) |
- |
15000 |
|
- |
5.15(Cold Bend Test-IS 10810 (Part 20).) |
- |
3000 |
|
- |
5.16(Cold Impact Test- IS 10810 (Part 21).) |
- |
3000 |
|
- |
6.1, Table 1(CORE IDENTIFICATION) |
- |
1000 |
|
- |
6.2(Core Identification by Numbers) |
- |
1000 |
|
- |
6.2.1(Preferred Arrangement of Marking) |
- |
1000 |
|
- |
6.2.2(Durability) |
- |
1000 |
|
- |
7.0(CABLE CODE) |
- |
1000 |
|
- |
9.0( IDENTIFICATION) |
- |
1000 |
|
- |
10.1(Packing ) |
- |
1000 |
|
- |
10.2(marking) |
- |
1000 |
|
- |
10.2.1(Standards marking) |
- |
1000 |
|
- |
13.3, 14.3(assembly of cores ) |
- |
1000 |
|
- |
6.1(General Requirements) |
- |
1000 |
|
- |
6.1.1(Colour Combination Green Yellow) |
- |
1000 |
|
- |
12.1(Conductor) |
- |
1000 |
|
- |
12.2, Table 4(insulation) |
- |
1000 |
|
- |
Table 4(Copper Purity test) |
- |
5000 |
|
- |
4.3.1 (e)(Fluorine content test (Fillers)) |
- |
10000 |
|
- |
4.3.1 (d)(Presence of fluorine test (Fillers)) |
- |
10000 |
|
- |
4.3.1 (c)(Conductivity test (Fillers)) |
- |
5000 |
|
- |
4.3.1 (b)(pH test (Fillers)) |
- |
5000 |
|
- |
4.3.1 (a)(HCl test (Fillers)) |
- |
5000 |
|
- |
5.7 (a)(HCl test (Assessment of halogen test)) |
- |
5000 |
|
- |
5.7 (b)(pH test (Assessment of halogen test)) |
- |
5000 |
|
- |
5.7 (c)(Conductivity test (Assessment of halogen test)) |
- |
5000 |
|
- |
5.7 (d)(Presence of fluorine test (Assessment of halogen test)) |
- |
10000 |
|
- |
5.7 (e)(Fluorine content test (Assessment of halogen test)) |
- |
10000 |
|
- |
4.5.4, 13.4, 14.4(Sheath : Tensile stregth ( After ageing) - IS 10810 (Part 7) ) |
- |
5000 |
|
- |
Table 2 ,( Clause 11.4, 12.4, 13.7 14.7 and 15.7 )(Insulation Resistance) |
- |
5000 |
|
- |
"Table 2 ( Clause 11.4, 12.4, 13.7 14.7 and 15.7 )"(Conductor Resistance) |
- |
2000 |
|
- |
Table 2 , Clause .5.13(Water immersion test (Effect of water on sheath) - TS Variation of Sheath) |
- |
5000 |
|
- |
Table 2 , Clause 5.13(Water immersion test (Effect of water on sheath) - Elongation Variation of Sheath) |
- |
5000 |
|
- |
"Table 2 ( Clause 11.4, 12.4, 13.7 14.7 and 15.7 )"(Hot Deformation) |
- |
5000 |
|
- |
Table 2, III.a.ii(Annealing test (for Cu,
before stranding)) |
- |
2000 |
|
- |
Table 2, II.a, b(Wrapping test before
stranding (for Al)) |
- |
2000 |
|
- |
|
Complete
|
|
16 Apr, 2026 |
- - |
12 |
IS 2465 (1984) |
Specification for cables for motor vehicles (Second Revision) |
- |
-
|
35000 View breakup
Single core PVC Insulated Unsheathed:
Rs. 16,545/- Single core PVC Insulated
Sheathed: Rs. 2,000/- extra for sheath.
Multi core with PVC Sheath: Rs. 1,200/-
for each additional core. Round and flat
tinned copper braids without further
covering for earthing: Rs. 1500/- Above
charges are excluding Material tests,
Ageing in oxygen bomb, Capacitance test,
Ozone resistance test, Effect of heat on
flexibility, Effect of oils, Effect of
lubricating oil, brake fluid, diesel and
petrol, Effect of cooling on flexibility. Rs
3,000/- extra for each material test.
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
7.1(Insulation) |
- |
1000 |
|
- |
7.3(Insulation) |
- |
1000 |
|
- |
8(Core Identification) |
- |
1000 |
|
- |
9(Laying up of cores) |
- |
1000 |
|
- |
10.1.1(Sheathing ) |
- |
1000 |
|
- |
10.2(Sheathing ) |
- |
1000 |
|
- |
3 & 6(Flexibility class) |
- |
1000 |
|
- |
3 & 6(Construction) |
- |
1000 |
|
- |
3 & 6(Diameter of wire(mm)) |
- |
1000 |
|
- |
3 & 6(Annealing test) |
- |
1000 |
|
- |
3 & 6(Persulphate Test) |
- |
1000 |
|
- |
3 & 6(Conductor resistance Test (ohm/km at 20˚c)) |
- |
1000 |
|
- |
7.2, 10.3, 11(Dimensions & thickness ) |
- |
2000 |
|
- |
7.2, 10.3, 11(Dimensions & thickness ) |
- |
2000 |
|
- |
7.2, 10.3, 11(Overall Dimension (mm)) |
- |
2000 |
|
- |
4.2 & 12.1(Without Ageing For Insulation
Tensile Strength (N/mm²)) |
- |
2000 |
|
- |
4.2 & 12.1, (f), 1(elongation at break (N/mm²)) |
- |
2000 |
|
- |
4.2 & 12.1, (f), 1(Tensile Strength at break (N/mm²)) |
- |
2000 |
|
- |
4.2 & 12.1, (e), 1(elongation test at break) |
- |
2000 |
|
- |
4.2 & 12.1, (e), 1(Tensile strength at break) |
- |
2000 |
|
- |
4.2 & 12.1, (f), 2(Ageing in air oven) |
- |
2000 |
|
- |
14(High Voltage Test) |
- |
2000 |
|
- |
16.1(CAPACITANCE TEST FOR PVC INSULATION IGNITION CABLE) |
- |
5000 |
|
- |
17.1(OZONE RESISTANCE TEST FOR IGNITION CABLES) |
- |
10000 |
|
- |
18.1(EFFECT OF HEAT ON FLEXIBILITY FOR IGNITION CABLES) |
- |
5000 |
|
- |
19.1(EFFECT OF OIL ON IGNITION CABLES) |
- |
5000 |
|
- |
19.2(EFFECT OF OIL ON IGNITION CABLES) |
- |
5000 |
|
- |
20.3(EFFECT OF LUBRICATING OIL) |
- |
5000 |
|
- |
20.3(EFFECT OF LUBRICATING OIL) |
- |
5000 |
|
- |
20.3(EFFECT OF BRAKE FLUID) |
- |
5000 |
|
- |
20.3(EFFECT OF BRAKE FLUID) |
- |
5000 |
|
- |
20.3(EFFECT OF DIESEL) |
- |
5000 |
|
- |
20.3(EFFECT OF DIESEL) |
- |
5000 |
|
- |
20.3(Increase in average diameter %) |
- |
5000 |
|
- |
20.3(Wrapping test) |
- |
5000 |
|
- |
21.1(EFFECT OF COOLING ON FLEXIBILITY) |
- |
5000 |
|
- |
21.2(EFFECT OF COOLING ON FLEXIBILITY) |
- |
5000 |
|
- |
21.2(EFFECT OF COOLING ON FLEXIBILITY) |
- |
5000 |
|
- |
22.1(FLAMMABILITY TEST) |
- |
2000 |
|
- |
22.1(FLAMMABILITY TEST) |
- |
2000 |
|
- |
23.1(Manufacturer's Identification) |
- |
1000 |
|
- |
23.1(Manufacturer's Identification) |
- |
1000 |
|
- |
24.1(PACKING AND MARKING) |
- |
1000 |
|
- |
24.2(PACKING AND MARKING) |
- |
1000 |
|
- |
24.2.1(PACKING AND MARKING) |
- |
1000 |
|
- |
|
Complete
|
|
16 Apr, 2026 |
- - |
13 |
IS 9968 : Part 1 (1988) |
Specification for elastomer insulatedcables: Part 1 for working voltages up to and including 1100 volts (First Revision) |
- |
-
|
25000 View breakup
Single Core for General services- Rs.
8,500/-, Single core for heat resisting
insulation- Rs. 9,000/- Single core for
silicon insulation- Rs. 10,000/-, Single
core sheathed cable, general Serices-Rs.
11000/-, Single core sheathed cable for
heat resisting insulation- Rs. 12,000/-,
Separated wire before stranding (If
provided) Rs. 1500/- Extra, Each
additional per core charge-Rs. 1500/-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
3.1( Copper Cooduetor) |
- |
1000 |
|
- |
3.2(Aluminium conductor) |
- |
1000 |
|
- |
4.1(INSULATION : lnsulation for General Service) |
- |
1000 |
|
- |
4.2(INSULATION : Heat Resisting insulation) |
- |
1000 |
|
- |
4.3(INSULATION : Silicone Rubber Insulation) |
- |
1000 |
|
- |
5.1(TAPE : Proofed Tape) |
- |
1000 |
|
- |
5.2(TAPE : 2 Polyethyl_ Terephthalate ( PETP ) Tape or
Plastic: Tape or Any Other SlIIitable Tape ) |
- |
1000 |
|
- |
5.3(TAPE : Giass Tape) |
- |
1000 |
|
- |
6.1(FILLERS : ) |
- |
1000 |
|
- |
7.1(BRAID : Textile Braid) |
- |
1000 |
|
- |
7.2(BRAID : Glass Braid ) |
- |
1000 |
|
- |
8.1(SHEATH : General Service Insulated Cables and Flexible
Cords) |
- |
1000 |
|
- |
8.2(SHEATH :Heat Resisting Insulated Cables) |
- |
1000 |
|
- |
9.1(PresenRtive Compound) |
- |
1000 |
|
- |
9.2(Varnish) |
- |
1000 |
|
- |
10( Conductor ) |
- |
1000 |
|
- |
11(Separator tape) |
- |
1000 |
|
- |
12.2(Insulation : Thickness of Insufatien) |
- |
2000 |
|
- |
12.4(Insulation : Allplication of Insulation) |
- |
1000 |
|
- |
13(CORE IDENTiFICATlON) |
- |
1000 |
|
- |
14(Tape) |
- |
1000 |
|
- |
15(BRAIDING) |
- |
1000 |
|
- |
19.2(Sheath : Thickness of Sheath) |
- |
2000 |
|
- |
19.4( Sheath :Colour) |
- |
1000 |
|
- |
20( Overall diameter) |
- |
2000 |
|
- |
21. (a)(Persulphate tests (for copper)) |
- |
5000 |
|
- |
21. (b)(Annealing Test (for coper)) |
- |
2000 |
|
- |
21. (c)( Tensile Test (for aluminium)) |
- |
2000 |
|
- |
21. (d)( Wrapping Test (for aluminium)) |
- |
2000 |
|
- |
21. (e)(Conductor Resistance ) |
- |
2000 |
|
- |
21.1( Tensile strength ) |
- |
2000 |
|
- |
22.1( Elongation) |
- |
2000 |
|
- |
21.1(type test : Ageing In air oven) |
- |
5000 |
|
- |
21.1(type test : Ageing in air bomb) |
- |
5000 |
|
- |
21.1(type test : Ageing In oxygen
bomb) |
- |
5000 |
|
- |
21.1(type test : Hot set elongation) |
- |
5000 |
|
- |
21.1(type test : Tear resistance ) |
- |
2000 |
|
- |
22.2(type test :Insulauon resistance High voltage (water immersron ) test) |
- |
5000 |
|
- |
22.2(type test : Flammability test
( applicable to cables
finished With SE 3 and
SE 4 sheaths only)
) |
- |
2000 |
|
- |
21(Water absorption test) |
- |
15000 |
|
- |
23(identification) |
- |
1000 |
|
- |
Cl No. 4.1(Ageing in oxygen bomb - Elongation) |
- |
5000 |
|
- |
Cl No. 4.1(Ageing in oxygen bomb - Tensile strength ) |
- |
5000 |
|
- |
Cl No. 4.1(Ageing in air bomb - Elongation) |
- |
5000 |
|
- |
Cl No. 4.1(Ageing in air bomb - Tensile strength ) |
- |
5000 |
|
- |
Cl No. 4.1(Ageing in air oven - Elongation) |
- |
5000 |
|
- |
Cl No. 4.1(Ageing in air oven - Tensile strength ) |
- |
5000 |
|
- |
Cl No. 22.2(High Voltage Test (Water Immersion)) |
- |
5000 |
|
- |
Cl No. 4.1(Insulation resistance) |
- |
5000 |
|
- |
Cl No. 22.4, Appendix B (Flexing test for cords for use with electric iron ) |
- |
5000 |
|
- |
Cl No. 22.2.2/22.2.3(High Voltage Test / Spark test) |
- |
2000 |
|
- |
Cl No. 23.1, 23.2(Identification) |
- |
1000 |
|
- |
|
Complete
|
|
16 Apr, 2026 |
- - |
14 |
IS 9857 (1990) |
Welding cables - Specification (First Revision) |
- |
-
|
20000 View breakup
Rs. 8000/- for general purpose and Rs.
10000/- for HOFR (20000 for complete testing charges)
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
4(Conductor : Material ) |
- |
1000 |
|
- |
5(SEPARATOR) |
- |
1000 |
|
- |
6(COVERING) |
- |
1000 |
|
- |
7(CONDUCTOR : CONSTRUCTION ) |
- |
1000 |
|
- |
8(S E P A R A T O R) |
- |
1000 |
|
- |
9.1(C O V E R I N G : Application ) |
- |
1000 |
|
- |
9.2(T h i c k n e s s o f C o v e r i n g) |
- |
2000 |
|
- |
9.3(T o l e r a n c e on Thickness o f C o v e r i n g) |
- |
2000 |
|
- |
9.4(A p p l i c a t i o n of C o v e r i n g) |
- |
1000 |
|
- |
9.5(Colour of C o v e r i n g) |
- |
1000 |
|
- |
10.1 a) 1)(Annealing test - IS 10810: Part 1) |
- |
2000 |
|
- |
10.1 a) 2)(Conductor resistance tes - IS 10810 : Part 5) |
- |
2000 |
|
- |
10.1 c) 1)(Physical tests for
covering : Tensile strength ) |
- |
2000 |
|
- |
10.1 c) 1)(Physical tests for
covering : Elongation at break ) |
- |
2000 |
|
- |
10.1 c) 2)(Physical tests for
covering - Ageing in Air oven : Tensile strength variation) |
- |
5000 |
|
- |
10.1 c) 2)(Physical tests for
covering -Ageing in Air oven : Elongation at break ) |
- |
5000 |
|
- |
10.1 c) 2)(Physical tests for
covering - Ageing in Air oven : Tensile strength ) |
- |
5000 |
|
- |
10.1 c) 2)(Physical tests for
covering -Ageing in Air oven : Elongation variation at break ) |
- |
5000 |
|
- |
10.1 c) 3)(Physical tests for
covering - Ageing in Air Bomb : Tensile strength variation ) |
- |
5000 |
|
- |
10.1 c) 3)(Physical tests for
covering -Ageing in Air Bomb : Elongation variation at break ) |
- |
5000 |
|
- |
10.1 c) 4)(Physical tests for
covering - Oil Resistance : Tensile strength variation ) |
- |
5000 |
|
- |
10.1 c) 4)(Physical tests for
covering - Oil Resistance : Elongation variation at break ) |
- |
5000 |
|
- |
10.1 c) 5)(Hot set test ) |
- |
5000 |
|
- |
10.1 c) 5)(Permanent set ) |
- |
5000 |
|
- |
11.1(High Voltage Test ( Water Immersion
Test )) |
- |
5000 |
|
- |
11.3(Static Flexibility Test) |
- |
2000 |
|
- |
11.4(Flammability Test) |
- |
2000 |
|
- |
12.1(Manufacturer's Identification) |
- |
1000 |
|
- |
12.2(Cable Identification) |
- |
1000 |
|
- |
12.3(Cable Code) |
- |
1000 |
|
- |
13.1(Packing ) |
- |
1000 |
|
- |
13.2(Marking) |
- |
1000 |
|
- |
14(CABLE RATINGS) |
- |
1000 |
|
- |
Table 4(Copper purity test) |
- |
5000 |
|
- |
Table 2(Oil resistance - Elongation) |
- |
5000 |
|
- |
Table 2(Oil resistance - Tensile strength ) |
- |
5000 |
|
- |
Table 2(Ageing in air bomb - Elongation) |
- |
5000 |
|
- |
Table 2(Ageing in air bomb - Tensile strength ) |
- |
5000 |
|
- |
Table 1 (Thickness of covering) |
- |
2000 |
|
- |
15.1 (d)(Heat Shock Test) |
- |
2000 |
|
- |
15.1 (d)(Hot Deformation Test) |
- |
3500 |
|
- |
15.1 (d)(Loss Of Mass Test) |
- |
5000 |
|
- |
|
Complete
|
|
16 Apr, 2026 |
- - |
15 |
IS 7098 : Part 1 (1988) |
Specification for crosslinked polyethylene insulated pvc sheathed cables: Part 1 for working voltages up to and including 1100 volts (First Revision) |
- |
-
|
25000 View breakup
Rs. 11,000/- for Category-01 & Rs.
21,000 for category Cl & C2 (1 core) Rs.
15,000/- for Category — 01 & Rs. 25,000
for category Cl & C2 (up to 4 cores) Rs 19,500/- for Category — 01 & Rs. 29,500
for category Cl & C2 (above 4 cores and
up to 12 Cores cable) Rs. 23,500/- for
Category — 01 & Rs. 33,500 for category
Cl & C2 (above 12 cores and up to 19
Cores cable) Rs. 28,500/- for Category —
01 & Rs. 38,500 for category Cl & C2
(above 19 cores and up to 37 Cores cable)
Rs. 33,500/- for Category —01 & Rs.
43,500 for category Cl & C2 (above 37
cores and up to 61 Cores cable)
Additional Rs. 2,500/- for armour test
Additional Rs. 2,500/- for optional tests
(cold bend / cold impact / Armour
Resistance)
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
3(CONDUCTOR: MATERIALS) |
- |
1000 |
|
- |
4(INSULATION : MATERIALS) |
- |
1000 |
|
- |
5.1(FILLER AND INNER SHEATH) |
- |
1000 |
|
- |
5.2(FILLER AND INNER SHEATH) |
- |
1000 |
|
- |
6(ARMOURING) |
- |
1000 |
|
- |
7(OUTER SHEATH) |
- |
1000 |
|
- |
8.1(CONDUCTOR: CONSTRUCTION) |
- |
1000 |
|
- |
8.2(PROTECTIVE BARRIER) |
- |
1000 |
|
- |
8.3(SIZE OF NEUTRAL CONDUCTOR) |
- |
1000 |
|
- |
9.1(Insulation Applied by extrusicn) |
- |
1000 |
|
- |
9.2(Thickness of Insulation - Average) |
- |
2000 |
|
- |
9.3(Thickness of Insulation - Minimum) |
- |
2000 |
|
- |
9.4(Application of Insulation) |
- |
1000 |
|
- |
10.1(Core Identification) |
- |
1000 |
|
- |
10.2(Core Identification- Neutral) |
- |
1000 |
|
- |
10.3(Core Identification by number ) |
- |
1000 |
|
- |
10.4(Core Identification by number - Neutral ) |
- |
1000 |
|
- |
11(LAVING UP OF CORES) |
- |
1000 |
|
- |
12.1 & 12.2(Inner sheath : Application) |
- |
1000 |
|
- |
12.3(Thickness of Inner Sheath) |
- |
2000 |
|
- |
13.1(Armouring: Application) |
- |
1000 |
|
- |
13.1.2(Armouring: Coverage ) |
- |
2000 |
|
- |
13.1.3(Armouring: Direction of Lay ) |
- |
1000 |
|
- |
13.2(Type of armour ) |
- |
1000 |
|
- |
13.3(Armouring : Dimensions -Wire Diameter) |
- |
2000 |
|
- |
13.3(Armouring : Dimensions -Formed wire ) |
- |
2000 |
|
- |
13.4(Armour: Joint) |
- |
1000 |
|
- |
13.5(Armouring : Resistance Test) |
- |
2000 |
|
- |
13.6 a)(ARMOURING: Tensile Strength) |
- |
2000 |
|
- |
13.6 b)(ARMOURING: Elongation ) |
- |
2000 |
|
- |
13.6 c)(ARMOURING: Torsion Test (For round wire ) ) |
- |
2000 |
|
- |
13.6 d)(ARMOURING: Winding Test(For formed wire)) |
- |
2000 |
|
- |
13.6 e)(ARMOURING: Uniformity of zinc coating) |
- |
2000 |
|
- |
13.6 f)(ARMOURING: Mass of zinc coating ) |
- |
2000 |
|
- |
13.6 g)(ARMOURING: Resistivity) |
- |
2000 |
|
- |
14.1(Outer Sheath : Application) |
- |
1000 |
|
- |
14.2(Colour of outer sheath) |
- |
1000 |
|
- |
14.3(Thickness of outer sheath - AVERAGE) |
- |
2000 |
|
- |
14.3(Thickness of outer sheath - minimum) |
- |
2000 |
|
- |
15.1 a) i)(Annealing Test ( For copper wire ) ) |
- |
2000 |
|
- |
15.1 a) ii)(Tensile test (for aluminium) - Before stranding ) |
- |
2000 |
|
- |
15.1 a) ii)(Tensile test (for aluminium) - After stranding ) |
- |
2000 |
|
- |
15.1 a) iii)(Wrapping test (for aluminium)) |
- |
2000 |
|
- |
15.1 a) iv)(Resistance test - Main conductor) |
- |
2000 |
|
- |
15.1 a) iv)(Resistance test - Neutral conductor) |
- |
2000 |
|
- |
15.1 d) i) (Phyaical tests for insulation : Tensile Test) |
- |
2000 |
|
- |
15.1 d) i) (Phyaical tests for insulation : Elongation) |
- |
2000 |
|
- |
15.1 d) ii) (Phyaical tests for insulation - Ageing in air Oven : Tensile Variation ) |
- |
5000 |
|
- |
15.1 d) ii) (Phyaical tests for insulation- Ageing in air oven : Elongation Variation ) |
- |
5000 |
|
- |
15.1 d) iii) (Phyaical tests for insulation : Hot set ) |
- |
5000 |
|
- |
15.1 d) iii) (Phyaical tests for insulation : Permanent set ) |
- |
5000 |
|
- |
15.1 d) iv) (Phyaical tests for insulation : Shrinkage ) |
- |
2000 |
|
- |
15.1 d) iv) (Phyaical tests for insulation : Shrinkage - Crack observed ) |
- |
2000 |
|
- |
15.1 d) v) (Insulation: Waterabsorption(gravimetric)) |
- |
10000 |
|
- |
15.1 e) i) (Physical tests for outer sheath : Tensile stregth) |
- |
2000 |
|
- |
15.1 e) i) (Physical tests for outer sheath : Elongation) |
- |
2000 |
|
- |
15.1 e) ii) (Physical tests for outer sheath- Ageing in air oven : Tensile stregth ) |
- |
5000 |
|
- |
15.1 e) ii) (Physical tests for outer sheath -Ageing in air oven : Elongation Variation ) |
- |
5000 |
|
- |
15.1 e) iii) (Sheath: Loss of mass in air oven) |
- |
5000 |
|
- |
15.1 e) iv) (Phyaical tests for Sheath : Shrinkage ) |
- |
2000 |
|
- |
15.1 e) iv) (Phyaical tests for Sheath : Shrinkage - Crack observed ) |
- |
2000 |
|
- |
15.1 e) v) (Sheath : Hot deformation) |
- |
5000 |
|
- |
15.1 e) vi) (Sheath : Heat shock test) |
- |
2000 |
|
- |
15.1 e) vii) (Sheath : Thermalstability) |
- |
2000 |
|
- |
15.1 f)(INSULATION RESISTANCE TEST : Volume resistivity ) |
- |
5000 |
|
- |
16.2(HIGH VOLTAGE TEST ) |
- |
2000 |
|
- |
16.3(FLAMMABILITY TEST : Period of Burning ) |
- |
2000 |
|
- |
16.3(FLAMMABILITY TEST : Unaffected length ) |
- |
2000 |
|
- |
16.9(Oxygen Index Test) |
- |
5000 |
|
- |
16.1(Flame Retardance Test on Single Cables) |
- |
2000 |
|
- |
16.11(Flame Retardance Test on Bunched Cables) |
- |
10000 |
|
- |
16.13(Test for Halogen Acid Gas Evolution) |
- |
5000 |
|
- |
16.14(Temperature Index) |
- |
5000 |
|
- |
17.1(Manufacturer'. identification) |
- |
1000 |
|
- |
17.2(cable Indentification ) |
- |
1000 |
|
- |
17.3(cable Code ) |
- |
1000 |
|
- |
15.4 (a)(Cold bend) |
- |
3000 |
|
- |
15.4 (b)(Cold impact) |
- |
3000 |
|
- |
Table 1(Ageing in air oven - Elongation on Insulation) |
- |
5000 |
|
- |
Table 1(Ageing in air oven - Tensile strength on Insulation) |
- |
5000 |
|
- |
Table 1(Ageing in air oven - Elongation on Insulation) |
- |
5000 |
|
- |
Table 1(Ageing in air oven - Tensile strength on Insulation) |
- |
5000 |
|
- |
Table 4(Copper purity test) |
- |
5000 |
|
- |
Cl No. 16.15(Smoke density test) |
- |
5000 |
|
- |
Table 2(Cold Impact test for Outer sheath) |
- |
3000 |
|
- |
Table 2(Cold bend test for Outer sheath) |
- |
3000 |
|
- |
15.1 e) ii) (Physical tests for outer sheath -Ageing in air oven : Elongation ) |
- |
5000 |
|
- |
|
Complete
|
|
16 Apr, 2026 |
- - |
16 |
IS 694 (2010) |
Polyvinyl chloride insulated unsheathed and sheathed cables/cords with rigid and flexible conductor for rated voltages up to and including 450/750 v (Fourth Revision) |
- |
-
|
25000 View breakup
Rs. 11,500/- for Single Core (category
01& 02), Additional Rs. 5,000/- (FR)
Additional Rs. 8,000/- (FRLSH) Rs.
15500/- up to 4 cores (Category-01 & 02)
Additional Rs. 10000/- (FR/FR-LSH); Rs.
17500/- above 4 cores and up to 12 Cores
(for Category- 01 & 02) Additional Rs.
12000/- (FR/FR- LSH) Rs. 20500/- above
12 cores and up to 25 Cores (Category01& 02) Additional Rs. 15000/- (FR/FRLSH) Rs. 1500/- Extra for persulphate test
for tinned copper only.
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
13(Cable code) |
- |
1000 |
|
- |
11.2(Legibility) |
- |
1000 |
|
- |
11.1(Durability) |
- |
1000 |
|
- |
11(Identification) |
- |
1000 |
|
- |
10.9(Additional ageing test (OU cables only) -HV test (at 60±3oC)) |
- |
5000 |
|
- |
10.4(Flammability test- Unaffected portion) |
- |
2000 |
|
- |
10.4(Flammability test-Burning after flame removal) |
- |
2000 |
|
- |
table 1 e) 3) (IR constant- max. Temp) |
- |
2000 |
|
- |
table 1 e) 3) (IR constant- Room temp ) |
- |
2000 |
|
- |
table 1 e) 3) (Volume Resistivity - Maximum temp) |
- |
2000 |
|
- |
table 1 e) 3) (Volume Resistivity - Room temp ) |
- |
2000 |
|
- |
10.2(HV (room temperature)) |
- |
2000 |
|
- |
10.1(HV (water immersion)) |
- |
5000 |
|
- |
10.1(HV (water immersion)) |
- |
5000 |
|
- |
10.8(Smoke density rating) |
- |
5000 |
|
- |
10.6(Halogen evolution) |
- |
5000 |
|
- |
10.7(Temperature index) |
- |
5000 |
|
- |
10.5(Oxygen index) |
- |
5000 |
|
- |
Table 1 iii) d) 9)(Cold impact for sheath) |
- |
3000 |
|
- |
Table 1 iii) d) 8)(Cold bend for sheath) |
- |
3000 |
|
- |
Table 1 iii) c) 9)(Cold impact for insulation) |
- |
3000 |
|
- |
Table 1 iii) c) 8)(Cold bend for insulation) |
- |
3000 |
|
- |
Table 1(Category Code) |
- |
1000 |
|
- |
Table 1 iii) d) 7)(Thermal stability- Sheath ) |
- |
2000 |
|
- |
Table 1 iii) c) 7)(Thermal stability- Insulation ) |
- |
2000 |
|
- |
Table 1 iii) d) 6)(Hot deformation -Indentation depth - Sheath ) |
- |
5000 |
|
- |
Table 1 iii) c) 6)(Hot deformation - Indentation depth- Insulation) |
- |
5000 |
|
- |
Table 1 iii) d) 5)(Heat shock-Sheath ) |
- |
2000 |
|
- |
Table 1 iii) c) 5)(Heat shock-Insulation ) |
- |
2000 |
|
- |
Table 1 iii) d) 4)(Cracks Observed) |
- |
2000 |
|
- |
Table 1 iii) d) 4)(Shrinkage- Sheath ) |
- |
2000 |
|
- |
Table 1 iii) c) 4)(Cracks Observed) |
- |
2000 |
|
- |
Table 1 iii) c) 4)(Shrinkage-Insulation) |
- |
2000 |
|
- |
Table 1 iii) d) 2)(Loss of mass- Sheath ) |
- |
5000 |
|
- |
Table 1 iii) c) 2)(Loss of mass- Insulation ) |
- |
5000 |
|
- |
Table 1 iii) d) 3)(Sheath- Elongation variation) |
- |
5000 |
|
- |
Table 1 iii) d) 3)(Sheath- TS variation) |
- |
5000 |
|
- |
Table 1 iii) d) 3)(Sheath- Elongation (After ageing)) |
- |
5000 |
|
- |
Table 1 iii) d) 3)(Sheath- Tensile strength (After ageing)) |
- |
5000 |
|
- |
Table 1 iii) d) 1)(Sheath- Elongation (Without ageing)) |
- |
2000 |
|
- |
Table 1 iii) d) 1)(Sheath -Tensile strength (Without ageing)) |
- |
2000 |
|
- |
Table 1 iii) c) 3)(Elongation variation) |
- |
5000 |
|
- |
Table 1 iii) c) 3)(TS variation) |
- |
5000 |
|
- |
Table 1 iii) c) 3)(Elongation (After ageing)) |
- |
5000 |
|
- |
Table 1 iii) c) 3)(Tensile strength (After ageing)) |
- |
5000 |
|
- |
Table 1 iii) c) 1)(Elongation (Without ageing)) |
- |
2000 |
|
- |
(Cl. 18.1.4)
(Cl. 19.1.5)
(Cl. 20.1.4)
(Cl. 22.1.4)(Colour of Sheath) |
- |
1000 |
|
- |
8.3(Thickness of Sheath) |
- |
2000 |
|
- |
5.2(Application ) |
- |
1000 |
|
- |
5.3(Thickness of Insulation) |
- |
2000 |
|
- |
9.1(Ovality) |
- |
2000 |
|
- |
9(Overall dimensions) |
- |
2000 |
|
- |
10.11(Per sulphate test (for tinned Cu cable only)) |
- |
5000 |
|
- |
4.2(Conductor resistance test) |
- |
2000 |
|
- |
4.1(Wrapping test (for Al)) |
- |
2000 |
|
- |
4.1(Tensile test (for Al)- After Stranding) |
- |
2000 |
|
- |
4.1(Tensile test (for Al)-Before Stranding) |
- |
2000 |
|
- |
4.1(Annealing test (for copper)) |
- |
2000 |
|
- |
(Cl.6.1.3 of IS 8130:2013)(Flexible Conductors (Classes 5)) |
- |
1000 |
|
- |
(Cl.6.1.3 of IS 8130:2013)( Flexible Conductors (Classes 5)) |
- |
1000 |
|
- |
(Cl.6.1.3 of IS 8130:2013)(Stranded circular non compacted conductors(Class-2)) |
- |
1000 |
|
- |
(Cl.6.1.3 of IS 8130:2013)(Stranded compacted circular conductors and shaped conductors (Class 2)) |
- |
1000 |
|
- |
(Cl.6.1.3 of IS 8130:2013)(Stranded circular non compacted conductors (Class-2)) |
- |
1000 |
|
- |
(Cl.6.1.3 of IS 8130:2013)(Stranded circular non compacted conductors (Class-2)) |
- |
1000 |
|
- |
(Cl.6.1.3 of IS 8130:2013)(Solid Conductor (Class 1)) |
- |
1000 |
|
- |
(Cl.6.1 of IS 8130:2013)(Solid Conductor (Class 1)) |
- |
1000 |
|
- |
(Cl.6.1 of IS 8130:2013)(Solid Conductor (Class 1)) |
- |
1000 |
|
- |
(Cl.16.1)
(Cl.19.1)(Conductor- Diameter ) |
- |
2000 |
|
- |
(Cl.16.1)
(Cl.19.1)(Conductor) |
- |
1000 |
|
- |
(Cl.16.1)
(Cl.19.1)(Conductor) |
- |
1000 |
|
- |
(Cl.16.1)
(Cl.19.1)(Conductor) |
- |
1000 |
|
- |
(Cl. 18.1.3)
(Cl. 19.1.4)
(Cl. 20.1.3)
(Cl. 21.1.3)
(Cl. 22.1.3)(Assembly of cores ) |
- |
1000 |
|
- |
12(CONSTRUCTION Core Identification) |
- |
1000 |
|
- |
8.1(Sheath Material ) |
- |
1000 |
|
- |
6.2(Filler) |
- |
1000 |
|
- |
6.1(Filler) |
- |
1000 |
|
- |
5.1(Insulation) |
- |
1000 |
|
- |
4.4(Joints in Conductor) |
- |
1000 |
|
- |
4.4(Joints in Conductor) |
- |
1000 |
|
- |
4.1(Conductor - Material) |
- |
1000 |
|
- |
4.1(Conductor - Material) |
- |
1000 |
|
- |
10.11(Persulphate Test ) |
- |
5000 |
|
- |
12.0(Core identification) |
- |
1000 |
|
- |
4, IS 8130(Construction of conductor) |
- |
1000 |
|
- |
Table 2, IS 8130(No fo wire in a conductor) |
- |
1000 |
|
- |
8.3(Minimum thickness of Sheath) |
- |
2000 |
|
- |
8.3(Avarage thickness of Sheath) |
- |
2000 |
|
- |
5.3(Minimum thickness of insulation) |
- |
2000 |
|
- |
5.3(Avarage thickness of insulation) |
- |
2000 |
|
- |
Table 4(Copper purity test) |
- |
5000 |
|
- |
5.4(Mechanical properties before and after ageing) |
- |
5000 |
|
- |
Table 1 iii) c) 1)(Tensile strength (Without ageing)) |
- |
2000 |
|
- |
10.3(Spark Test) |
- |
2000 |
|
- |
|
Complete
|
|
16 Apr, 2026 |
- - |
17 |
IS 14255 (1995) |
Aertal bunched cables - For working voltages up to and including 1100 Volts - Specification |
- |
-
|
25000 View breakup
Rs. 13,500/-, Rs. 1000 for each additional
core XLPE, Rs. 2000/- for PVC Sheathed
cable for weather proof, Rs.11,000/-
additional in case of PE outer sheath.
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
4.1(Phase/Street Lighting conductor) |
- |
1000 |
|
- |
4.2(Messenger (Neutral Conductor or Otherwise)) |
- |
1000 |
|
- |
5.1(Insulation) |
- |
1000 |
|
- |
6.1(Flexibility class) |
- |
1000 |
|
- |
6.2(Compactness) |
- |
1000 |
|
- |
6.2(No of strands) |
- |
1000 |
|
- |
6.2(Surface) |
- |
1000 |
|
- |
6.3(Protective barrier) |
- |
1000 |
|
- |
6.4(size of street lighting conductor) |
- |
1000 |
|
- |
6.5(Size of messenger conductor ) |
- |
1000 |
|
- |
6.6(Joints in messenger conductor ) |
- |
1000 |
|
- |
6.6(Direction of outer layer) |
- |
1000 |
|
- |
7.1(Insulation) |
- |
1000 |
|
- |
7.2( Thickness of insulation) |
- |
2000 |
|
- |
7.3(Tolerance on thickness of insulation ) |
- |
2000 |
|
- |
7.4(Aplication of the insulation ) |
- |
2000 |
|
- |
7.5(Colour of the insulation ) |
- |
1000 |
|
- |
8.1(Core identification) |
- |
1000 |
|
- |
8.2(Core identification) |
- |
1000 |
|
- |
8.3(Identification by other means) |
- |
1000 |
|
- |
9.1(Assembly (Laying up)) |
- |
1000 |
|
- |
9.2(Assembly (Laying up)) |
- |
1000 |
|
- |
9.3(Direction of lay) |
- |
1000 |
|
- |
10.1 a) i)(Tests on phase/street light conductor: tensile test - Test method IS10810:Part 2) |
- |
2000 |
|
- |
10.1 a) ii)(Wrapping test - 10810: Part 3) |
- |
2000 |
|
- |
10.1 a) iii)(Resistance test - IS10810: Part 5) |
- |
2000 |
|
- |
10.1 b) i)(Test on messenger conductor: Breaking load - IS 10810: Part 2) |
- |
2000 |
|
- |
10.1 b) ii)(Test on messenger conductor: Elongation test - Cl 11.3) |
- |
2000 |
|
- |
10.1 b) iii)(Test on messenger conductor: Resistance test - IS 10810: Part 5) |
- |
2000 |
|
- |
10.1 c) i)(Physical tests for XLPE Insulation:
Tensile strength - IS 10810: Part 7) |
- |
2000 |
|
- |
10.1 c) i)(Physical tests for XLPE Insulation:
elongation at break - IS 10810: part 7) |
- |
2000 |
|
- |
10.1 c) ii)(Ageing in air oven : Tensile strength variation - IS 10810:Part 11) |
- |
5000 |
|
- |
10.1 c) ii)(Ageing in air oven : Elongation variation- IS 10810: Part 11) |
- |
5000 |
|
- |
10.1 c) iii)(Hot set test: Elongation under load - IS 10810: Part 30) |
- |
5000 |
|
- |
10.1 c) iii)(Hot set test: Permanent elongation (set) after cooling - IS 10810: Part 30) |
- |
5000 |
|
- |
10.1 c) iv)(Shrinkage test : Shrinkage - 10810:Part 12) |
- |
2000 |
|
- |
10.1 c) iv)(Shrinkage test : Crack Observed - 10810:Part 12) |
- |
2000 |
|
- |
10.1 c) v)(Water ahsorption (Gravimetric) - IS 10810: Part 33 ) |
- |
10000 |
|
- |
10.1 d) i)(Physical test for PE insulation:
Tensile strength - IS 10810: Part 7 ) |
- |
2000 |
|
- |
10.1 d) i)(Physical test for PE insulation: elongation at break - IS 10810: Part 7) |
- |
2000 |
|
- |
10.1 d) ii)(Melt flow index- IS 10810: Part 23) |
- |
2000 |
|
- |
10.1 d) iv)(Vicat softening point -IS 10810: Part 22) |
- |
2000 |
|
- |
10.1 d) v)(Environmental stress cracking -IS 10810:Part29) |
- |
2000 |
|
- |
10.1 f)(Insulation resistance (Volume resistivity) test a) volume resistivity at 27°C - IS 10810: Part 43) |
- |
2000 |
|
- |
10.1 f)(Insulation resistance (Volume resistivity) test b) volume resistivity at 70°C - IS 10810: Part 43) |
- |
2000 |
|
- |
10.1 g)(High voltage test - IS10810:Part 45) |
- |
2000 |
|
- |
11.4(Bending Test on the Completed Cable ( Optional) ) |
- |
2000 |
|
- |
11.4(Bending Test on the Completed Cable ( Optional)) |
- |
2000 |
|
- |
|
Complete
|
|
16 Apr, 2026 |
- - |
18 |
IS 1554 : Part 1 (1988) |
Specification for pvc insulated (Heavy Duty) electric cables: Part 1 for working voltages up to and including 1100 v (Third Revision) |
- |
-
|
25000 View breakup
Rs. 10,000/- for Category-01& Rs. 20,000
for category Cl & C2 (1 core) Rs. 14,000/-
for Category — 01 & Rs. 24,000 for
category Cl & C2 (up to 4 cores) Rs.
18,500/- for Category — 01& Rs. 28,500
for category Cl & C2 (above 4 cores and
up to 12 Cores cable) Rs. 22,500/- for
Category —01& Rs. 32,500 for category
Cl & C2 (above 12 cores and up to 19
Cores cable) Rs. 27,500/- for Category —
01& Rs. 37,500 for category C1 & C2
(above 19 cores and up to 37 Cores cable)
Rs. 32,500/- for Category —01& Rs.
42,500 for category Cl & C2 (above 37
cores and up to 61 Cores cable)
Additional Rs. 2,500/- for armour test
Additional Rs. 2,500/- for optional tests
(cold bend / cold impact / Armour
Resistance)
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
3.1(MATERIALS : CONDUCTOR) |
- |
1000 |
|
- |
4.1.1(INSULATION : General Purjose Insulaiion) |
- |
1000 |
|
- |
4.1.2(INSULATION : Heat Resisting Insulation) |
- |
1000 |
|
- |
5.1(MATERIALS : FILLER AND INNER SHEATH) |
- |
1000 |
|
- |
5.2(MATERIALS : FILLER AND INNER SHEATH) |
- |
1000 |
|
- |
6.1(MATERIALS : ARMGURING) |
- |
1000 |
|
- |
6.2(MATERIALS : ARMGURING) |
- |
1000 |
|
- |
7.1.1(OUTER SHEATH : For Cables with General Purpose InsuIafion) |
- |
1000 |
|
- |
7.1.2(OUTER SHEATH : For Cables with Heat Resisting InsuIalion) |
- |
1000 |
|
- |
8.1(CONSTRUCTION : CONDUCTOR) |
- |
1000 |
|
- |
8.2(CONSTRUCTION : CONDUCTOR) |
- |
1000 |
|
- |
9.1(INSULATION ) |
- |
1000 |
|
- |
9.2(INSULATION : Thickness of Insulation) |
- |
2000 |
|
- |
9.3(INSULATION :Tolerance on Thickness of Insulation) |
- |
2000 |
|
- |
9.4(INSULATION : Application of Insulation) |
- |
1000 |
|
- |
10.1(CORE IDENTIFICATION) |
- |
1000 |
|
- |
10.2(CORE IDENTIFICATION) |
- |
1000 |
|
- |
10.3(CORE IDENTIFICATION) |
- |
1000 |
|
- |
10.3.1(Arrangement of Marking) |
- |
1000 |
|
- |
11.1(LAYING UP OF CORES) |
- |
1000 |
|
- |
11.2(LAYING UP OF CORES) |
- |
1000 |
|
- |
12.1(INNER SHEATH) |
- |
1000 |
|
- |
12.2(INNER SHEATH) |
- |
1000 |
|
- |
12.3(INNER SHEATH :Thickness of Inner Sheath) |
- |
2000 |
|
- |
12.3.1(INNER SHEATH :Thickness of Inner Sheath) |
- |
2000 |
|
- |
13.1.1(ARMOURING : Application) |
- |
1000 |
|
- |
13.1.2(Armouring: Coverage ) |
- |
2000 |
|
- |
13.1.3(ARMOURING : Direction of lay ) |
- |
1000 |
|
- |
13.1.4(ARMOURING : Application) |
- |
1000 |
|
- |
13.2(ARMOURING : Type of Armour) |
- |
1000 |
|
- |
13.2.1(ARMOURING : Type of Armour) |
- |
1000 |
|
- |
13.3(Armouring : Dimensions -Wire Diameter) |
- |
2000 |
|
- |
13.3(Armouring : Dimensions -Formed wire ) |
- |
2000 |
|
- |
13.4(ARMOURING : Joints) |
- |
1000 |
|
- |
13.5.1(ARMOURING : Resistance) |
- |
2000 |
|
- |
13.5.2(ARMOURING : Resistance) |
- |
2000 |
|
- |
13.6 a)(ARMOURING: Tensile Strength) |
- |
2000 |
|
- |
13.6 b)(ARMOURING: Elongation ) |
- |
2000 |
|
- |
13.6 c)(ARMOURING: Torsion Test (For round wire ) ) |
- |
2000 |
|
- |
13.6 d)(ARMOURING: Winding Test(For formed wire)) |
- |
2000 |
|
- |
13.6 e)(ARMOURING: Uniformity of zinc coating) |
- |
2000 |
|
- |
13.6 f)(ARMOURING: Mass of zinc coating ) |
- |
2000 |
|
- |
13.6 g)(ARMOURING: Resistivity) |
- |
2000 |
|
- |
14.1(OUTER SHEATH) |
- |
1000 |
|
- |
14.2(OUTER SHEATH) |
- |
1000 |
|
- |
14.3(OUTER SHEATH : Colour ) |
- |
1000 |
|
- |
14.4.1(Thickness of Outer Sheath : Unarmowed Cables) |
- |
2000 |
|
- |
14.4.2(Thickness of Outer Sheath : Armoured Cables) |
- |
2000 |
|
- |
15.1 a) 1)(Tests on conductor : Annealing test ( for copper )) |
- |
2000 |
|
- |
15.1 a) 2)(Tensile test (for aluminium) - Before stranding ) |
- |
2000 |
|
- |
15.1 a) 2)(Tensile test (for aluminium) - After stranding ) |
- |
2000 |
|
- |
15.1 a) 3)(Tests on conductor : Wrapping test ( for aluminium )) |
- |
2000 |
|
- |
15.1 a) 4)(Tests on conductor : Conductor resistance test) |
- |
2000 |
|
- |
15.1 a) 4)(Resistance test - Neutral conductor ) |
- |
2000 |
|
- |
15.1 d)1)(Phyaical tests for insulation : Tensile Test) |
- |
2000 |
|
- |
15.1 d)1)(Phyaical tests for insulation : Elongation ) |
- |
2000 |
|
- |
15.1 d)1)(Physical tests for sheath : Tensile stregth ) |
- |
2000 |
|
- |
15.1 d)1)(Physical tests for sheath : Elongation ) |
- |
2000 |
|
- |
15.1 d)2)(Phyaical tests for insulation- Ageing in air Oven : Tensile Test) |
- |
5000 |
|
- |
15.1 d)2)(Phyaical tests for insulation - Ageing in air oven : Elongation ) |
- |
5000 |
|
- |
15.1 d)2)(Phyaical tests for insulation - Ageing in air Oven : Tensile Variation ) |
- |
5000 |
|
- |
15.1 d)2)(Phyaical tests for insulation- Ageing in air oven : Elongation Variation ) |
- |
5000 |
|
- |
15.1 d)2)(Physical tests for outer sheath- Ageing in air oven : Tensile stregth ) |
- |
5000 |
|
- |
15.1 d)2)(Physical tests for outer sheath -Ageing in air oven : Elongation ) |
- |
5000 |
|
- |
15.1 d)2)(Physical tests for outer sheath- Ageing in air oven : Tensile stregth Variation ) |
- |
5000 |
|
- |
15.1 d)2)(Physical tests for outer sheath -Ageing in air oven : Elongation Variation ) |
- |
5000 |
|
- |
15.1 d)3)(Phyaical tests for insulation : Shrinkage ) |
- |
2000 |
|
- |
15.1 d)3)(Phyaical tests for insulation : Shrinkage - Crack observed ) |
- |
2000 |
|
- |
15.1 d)3)(Phyaical tests for Sheath : Shrinkage ) |
- |
2000 |
|
- |
15.1 d)3)(Phyaical tests for Sheath : Shrinkage - Crack observed ) |
- |
2000 |
|
- |
15.1 d)4)(Hot deformation : Insulation ) |
- |
2000 |
|
- |
15.1 d)4)(Hot deformation : Sheath ) |
- |
2000 |
|
- |
15.1 d)5)( Loss of mass in air oven- Insulation ) |
- |
5000 |
|
- |
15.1 d)5)( Loss of mass in air oven- sheath ) |
- |
5000 |
|
- |
15.1 d)6)(Heat shock test- Insulation ) |
- |
2000 |
|
- |
15.1 d)6)(Heat shock test- sheath ) |
- |
2000 |
|
- |
15.1 d)7)(Thermal stability- insulation ) |
- |
2000 |
|
- |
15.1 d)7)(Thermal stability- Sheath ) |
- |
2000 |
|
- |
15.1 e)(Insulation resistance test : Volume Resistivity ) |
- |
2000 |
|
- |
15.1 e)(Insulation resistance test : IR Constant ) |
- |
2000 |
|
- |
15.1 f)(High voltage test ( water immersion test )) |
- |
5000 |
|
- |
15.1 g)(High voltage test at room temperature) |
- |
2000 |
|
- |
15.1 g)(High voltage test at room temperature) |
- |
2000 |
|
- |
15.4 a)(Cold bend test- Insulation ( Optional test)) |
- |
3000 |
|
- |
15.4 a)(Cold bend test- Sheath ( Optional test)) |
- |
3000 |
|
- |
15.4 b)(Cold impact test- Insulation ( Optional test)) |
- |
3000 |
|
- |
15.4 b)(Cold impact test- Sheath ( Optional test)) |
- |
3000 |
|
- |
15.4 c)(Armour resistance test ( for other than mining cables ).- Optional test ) |
- |
2000 |
|
- |
16.1(DETAILS OF TESTS : General) |
- |
1000 |
|
- |
16.2(DETAILS OF TESTS : High Voltage Test at Room Temperature) |
- |
2000 |
|
- |
16.3.1(High Voltage Test ( Water Immersion Test ) : a.c. Test) |
- |
2000 |
|
- |
16.3.2(High Voltage Test ( Water Immersion Test ) : d.c. Test) |
- |
5000 |
|
- |
16.4(Flammability Test) |
- |
2000 |
|
- |
16.5(Oxygen Index Test) |
- |
5000 |
|
- |
16.6(Flame Retardance Test on Single Cables) |
- |
2000 |
|
- |
16.7(Flame Retardance Test on Bunched Cables) |
- |
10000 |
|
- |
16.9(Test for Halogen Acid Gas Evolution) |
- |
5000 |
|
- |
16.1(Temperature Index) |
- |
5000 |
|
- |
17.1(IDENTIFICATION : Manufacturer’s Identification) |
- |
1000 |
|
- |
17.2(IDENTIFICATION : Cable Identification) |
- |
1000 |
|
- |
17.2.1(IDENTIFICATION : Cable Identification) |
- |
1000 |
|
- |
17.3(IDENTIFICATION : Cable Code) |
- |
1000 |
|
- |
15.1.e(Insulation resistance Test- Insulation resistance At Maximum rated temperature temperature) |
- |
2000 |
|
- |
15.1.e(Insulation resistance Test- Insulation resistance constant At Room temperature) |
- |
2000 |
|
- |
15.1.e(Insulation resistance Test- Volume Resistivity At Maximum rated temperature temperature) |
- |
2000 |
|
- |
15.1.e(Insulation resistance Test- Volume Resistivity At Room temperature) |
- |
2000 |
|
- |
16.4(Flammability Test- Un affected portion) |
- |
2000 |
|
- |
16.4(Flammability Test- Period of Burning) |
- |
2000 |
|
- |
9.3(Minimum Thickness of Reduce core insulation) |
- |
2000 |
|
- |
9.2(Thickness of Reduce core insulation) |
- |
2000 |
|
- |
3.1 Table 2
IS 8130(Number of wires in the conductor) |
- |
1000 |
|
- |
Cl No. 16.10(Smoke density test) |
- |
5000 |
|
- |
Table 4(Copper purity test) |
- |
5000 |
|
- |
|
Complete
|
|
16 Apr, 2026 |
- - |
19 |
IS 2141 (2000) |
Hot dip galvanized stay strand - Specification (Fourth Revision) |
- |
-
|
20000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
4(S) |
- |
500 |
|
- |
4(P) |
- |
500 |
|
- |
9.2 referes to IS 4826, Table 1(Mass of Zinc coating- as per IS 6745 for 0.2 to 0.32 mm dia For Hard Core) |
- |
2000 |
|
- |
9.2 referes to IS 4826, Table 1(Mass of Zinc coating- as per IS 6745 for 0.32 to 0.40 mm dia For Hard Core) |
- |
2000 |
|
- |
9.2 referes to IS 4826, Table 1(Mass of Zinc coating- as per IS 6745 for 0.40 to 0.50 mm dia For Hard Core) |
- |
2000 |
|
- |
9.2 referes to IS 4826, Table 1(Mass of Zinc coating- as per IS 6745 for 0.50 to 0.56 mm dia For Hard Core) |
- |
2000 |
|
- |
9.2 referes to IS 4826, Table 1(Mass of Zinc coating- as per IS 6745 for 0.56 to 0.63 mm dia For Hard Core) |
- |
2000 |
|
- |
9.2 referes to IS 4826, Table 1(Mass of Zinc coating- as per IS 6745 for 0.63 to 0.71 mm dia For Hard Core) |
- |
2000 |
|
- |
9.2 referes to IS 4826, Table 1(Mass of Zinc coating- as per IS 6745 for 0.71 to 0.80 mm dia For Hard Core) |
- |
2000 |
|
- |
9.2 referes to IS 4826, Table 1(Mass of Zinc coating- as per IS 6745 for 0.80 to 0.90 mm dia For Hard Core) |
- |
2000 |
|
- |
9.2 referes to IS 4826, Table 1(Mass of Zinc coating- as per IS 6745 for 0.90 to 1.00 mm dia For Hard Core) |
- |
2000 |
|
- |
9.2 referes to IS 4826, Table 1(Mass of Zinc coating- as per IS 6745 for 1.00 to 1.25 mm dia For Hard Core) |
- |
2000 |
|
- |
9.2 referes to IS 4826, Table 1(Mass of Zinc coating- as per IS 6745 for 1.25 to 1.40 mm dia For Hard Core) |
- |
2000 |
|
- |
9.2 referes to IS 4826, Table 1(Mass of Zinc coating- as per IS 6745 for 1.40 to 1.60 mm dia For Hard Core) |
- |
2000 |
|
- |
9.2 referes to IS 4826, Table 1(Mass of Zinc coating- as per IS 6745 for 1.60 to 1.80 mm dia For Hard Core) |
- |
2000 |
|
- |
9.2 referes to IS 4826, Table 1(Mass of Zinc coating- as per IS 6745 fo1.80 to 2.00 mm dia For Hard Core) |
- |
2000 |
|
- |
9.2 referes to IS 4826, Table 1(Mass of Zinc coating- as per IS 6745 for 2.00 to 2.24 mm dia For Hard Core) |
- |
2000 |
|
- |
9.2 referes to IS 4826, Table 1(Mass of Zinc coating- as per IS 6745 for 2.24 to 2.50 mm dia For Hard Core) |
- |
2000 |
|
- |
9.2 referes to IS 4826, Table 1(Mass of Zinc coating- as per IS 6745 for 2.50 to 2.80 mm dia For Hard Core) |
- |
2000 |
|
- |
9.2 referes to IS 4826, Table 1(Mass of Zinc coating- as per IS 6745 for 0.2.80 to 3.15 mm dia For Hard Core) |
- |
2000 |
|
- |
9.2 referes to IS 4826, Table 1(Mass of Zinc coating- as per IS 6745 for3.15 to 3.55 mm dia For Hard Core) |
- |
2000 |
|
- |
9.2 referes to IS 4826, Table 1(Mass of Zinc coating- as per IS 6745 for 3.55 to 4.00 mm dia For Hard Core) |
- |
2000 |
|
- |
9.2 referes to IS 4826, Table 1(Mass of Zinc coating- as per IS 6745 for 4.00 to 5.00 mm dia For Hard Core) |
- |
2000 |
|
- |
9.2 referes to IS 4826, Table 1(Mass of Zinc coating- as per IS 6745 for 5.00 to 7.10 mm dia For Hard Core) |
- |
2000 |
|
- |
9.2 referes to IS 4826, Table 1(Mass of Zinc coating- as per IS 6745 for 7.10 to 10.00 mm dia For Hard Core) |
- |
2000 |
|
- |
9.2 referes to IS 4826, Table 1(Uniformity of zinc coating- As per IS 2633 for Dia 0.20 to 0.32 mm For Hard Core) |
- |
2000 |
|
- |
9.2 referes to IS 4826, Table 1(Uniformity of zinc coating- As per IS 2633 for Dia 0.32 to 0.40mm For Hard Core) |
- |
2000 |
|
- |
9.2 referes to IS 4826, Table 1(Uniformity of zinc coating- As per IS 2633 for Dia 0.40 to 0.50mm For Hard Core) |
- |
2000 |
|
- |
9.2 referes to IS 4826, Table 1(Uniformity of zinc coating- As per IS 2633 for Dia 0.50 to 0.56 mm For Hard Core) |
- |
2000 |
|
- |
9.2 referes to IS 4826, Table 1(Uniformity of zinc coating- As per IS 2633 for Dia 0.56 to 0.63 mm For Soft Core) |
- |
2000 |
|
- |
9.2 referes to IS 4826, Table 1(Mass of Zinc coating- as per IS 6745 for 0.63 to 0.71 mm dia For Soft Core) |
- |
2000 |
|
- |
9.2 referes to IS 4826, Table 1(Mass of Zinc coating- as per IS 6745 for 0.71 to 0.80 mm dia For Soft Core) |
- |
2000 |
|
- |
9.2 referes to IS 4826, Table 1(Uniformity of zinc coating- As per IS 2633 for Dia 0.80 to 0.90 mm For Soft Core) |
- |
2000 |
|
- |
9.2 referes to IS 4826, Table 1(Uniformity of zinc coating- As per IS 2633 for Dia 0.90 to 1.00 mm For Soft Core) |
- |
2000 |
|
- |
9.2 referes to IS 4826, Table 1(Mass of Zinc coating- as per IS 6745 for 1.00 to 1.25 mm dia For Soft Core) |
- |
2000 |
|
- |
9.2 referes to IS 4826, Table 1(Mass of Zinc coating- as per IS 6745 for 1.25 to 1.40 mm dia For Soft Core) |
- |
2000 |
|
- |
9.2 referes to IS 4826, Table 1(Mass of Zinc coating- as per IS 6745 for 1.40 to 1.60 mm dia For Soft Core) |
- |
2000 |
|
- |
9.2 referes to IS 4826, Table 1(Uniformity of zinc coating- As per IS 2633 for Dia 1.60 to 1.80 mm For Hard Core) |
- |
2000 |
|
- |
9.2 referes to IS 4826, Table 1(Uniformity of zinc coating- As per IS 2633 for Dia 1.80 to2.00 mm For Hard Core) |
- |
2000 |
|
- |
9.2 referes to IS 4826, Table 1(Mass of Zinc coating- as per IS 6745 For 2.00 to 2.24 mm dia For Soft Core) |
- |
2000 |
|
- |
9.2 referes to IS 4826, Table 1(Uniformity of zinc coating- As per IS 2633 for Dia 2.24 to2.50 mm For Hard Core For Hard Core) |
- |
2000 |
|
- |
9.2 referes to IS 4826, Table 1(Uniformity of zinc coating- As per IS 2633 for Dia 2.50 to2.80 mm For Hard Core) |
- |
2000 |
|
- |
9.2 referes to IS 4826, Table 1(Uniformity of zinc coating- As per IS 2633 for Dia 2.80 to3.15 mm For Hard Core) |
- |
2000 |
|
- |
9.2 referes to IS 4826, Table 1(Uniformity of zinc coating- As per IS 2633 for Dia 3.15 to 3.55 mm For Hard Core) |
- |
2000 |
|
- |
9.2 referes to IS 4826, Table 1(Uniformity of zinc coating- As per IS 2633 for Dia 3.55 to 4.00 mm For Hard Core) |
- |
2000 |
|
- |
9.2 referes to IS 4826, Table 1(Uniformity of zinc coating- As per IS 2633 for Dia4.00 to5.00 mm For Hard Core) |
- |
2000 |
|
- |
9.2 referes to IS 4826, Table 1(Uniformity of zinc coating- As per IS 2633 for Dia 5.00 to 7.10 mm For Hard Core) |
- |
2000 |
|
- |
9.2 referes to IS 4826, Table 1(Uniformity of zinc coating- As per IS 2633 for Dia 7.10 to10.00 mm For Hard Core) |
- |
2000 |
|
- |
9.2 referes to IS 4826, Table 1(Mass of Zinc coating- as per IS 6745 for 0.2 to 0.32 mm dia For Soft Core) |
- |
2000 |
|
- |
9.2 referes to IS 4826, Table 1(Mass of Zinc coating- as per IS 6745 for 0.32 to 0.40 mm dia For Soft Core) |
- |
2000 |
|
- |
9.2 referes to IS 4826, Table 1(Mass of Zinc coating- as per IS 6745 for 0.40 to 0.50 mm dia For Soft Core) |
- |
2000 |
|
- |
9.2 referes to IS 4826, Table 1(Mass of Zinc coating- as per IS 6745 for 0.50 to 0.56 mm dia For Soft Core) |
- |
2000 |
|
- |
9.2 referes to IS 4826, Table 1(Mass of Zinc coating- as per IS 6745 for 0.56 to 0.63 mm dia For Soft Core) |
- |
2000 |
|
- |
9.2 referes to IS 4826, Table 1(Mass of Zinc coating- as per IS 6745 for 0.80 to 0.90 mm dia For Soft Core) |
- |
2000 |
|
- |
9.2 referes to IS 4826, Table 1(Mass of Zinc coating- as per IS 6745 for 0.90 to 1.00 mm dia For Soft Core) |
- |
2000 |
|
- |
9.2 referes to IS 4826, Table 1(Mass of Zinc coating- as per IS 6745 for 1.60 to 1.80 mm dia For Soft Core) |
- |
2000 |
|
- |
9.2 referes to IS 4826, Table 1(Mass of Zinc coating- as per IS 6745 fo1.80 to 2.00 mm dia) |
- |
2000 |
|
- |
9.2 referes to IS 4826, Table 1(Mass of Zinc coating- as per IS 6745 for 2.24 to 2.50 mm dia For Soft Core) |
- |
2000 |
|
- |
9.2 referes to IS 4826, Table 1(Mass of Zinc coating- as per IS 6745 for 2.50 to 2.80 mm dia For Soft Core) |
- |
2000 |
|
- |
9.2 referes to IS 4826, Table 1(Mass of Zinc coating- as per IS 6745 for 2.80 to 3.15 mm dia For Soft Core) |
- |
2000 |
|
- |
9.2 referes to IS 4826, Table 1(Mass of Zinc coating- as per IS 6745 for3.15 to 3.55 mm dia For Soft Core) |
- |
2000 |
|
- |
9.2 referes to IS 4826, Table 1(Mass of Zinc coating- as per IS 6745 for 3.55 to 4.00 mm dia For Soft Core) |
- |
2000 |
|
- |
9.2 referes to IS 4826, Table 1(Mass of Zinc coating- as per IS 6745 for 4.00 to 5.00 mm dia For Soft Core) |
- |
2000 |
|
- |
9.2 referes to IS 4826, Table 1(Mass of Zinc coating- as per IS 6745 for 7.10 to 10.00 mm dia For Soft Core) |
- |
2000 |
|
- |
9.2 referes to IS 4826, Table 1(Uniformity of zinc coating- As per IS 2633 for Dia 0.20 to 0.32 mm For Soft Core) |
- |
2000 |
|
- |
9.2 referes to IS 4826, Table 1(Uniformity of zinc coating- As per IS 2633 for Dia 0.32 to 0.40mm For Soft Core) |
- |
2000 |
|
- |
9.2 referes to IS 4826, Table 1(Uniformity of zinc coating- As per IS 2633 for Dia 0.40 to 0.50mm For Soft Core) |
- |
2000 |
|
- |
9.2 referes to IS 4826, Table 1(Uniformity of zinc coating- As per IS 2633 for Dia 0.50 to 0.56 mm For Soft Core) |
- |
2000 |
|
- |
9.2 referes to IS 4826, Table 1(Uniformity of zinc coating- As per IS 2633 for Dia 0.63 to 0.71 mm For Soft Core) |
- |
2000 |
|
- |
9.2 referes to IS 4826, Table 1(Uniformity of zinc coating- As per IS 2633 for Dia 1.00 to 1.25 mm For Soft Core) |
- |
2000 |
|
- |
9.2 referes to IS 4826, Table 1(Uniformity of zinc coating- As per IS 2633 for Dia 1.25 to1.40 mm For Soft Core) |
- |
2000 |
|
- |
9.2 referes to IS 4826, Table 1(Uniformity of zinc coating- As per IS 2633 for Dia 1.60 to 1.80 mm For Soft Core) |
- |
2000 |
|
- |
9.2 referes to IS 4826, Table 1(Uniformity of zinc coating- As per IS 2633 for Dia 1.80 to2.00 mm For Soft Core) |
- |
2000 |
|
- |
9.2 referes to IS 4826, Table 1(Uniformity of zinc coating- As per IS 2633 for Dia2.00 to2.24 mm For Soft Core) |
- |
2000 |
|
- |
9.2 referes to IS 4826, Table 1(Uniformity of zinc coating- As per IS 2633 for Dia 2.24 to2.50 mm For Soft Core) |
- |
2000 |
|
- |
9.2 referes to IS 4826, Table 1(Uniformity of zinc coating- As per IS 2633 for Dia 2.50 to2.80 mm For Soft Core) |
- |
2000 |
|
- |
9.2 referes to IS 4826, Table 1(Uniformity of zinc coating- As per IS 2633 for Dia 2.80 to3.15 mm For Soft Core) |
- |
2000 |
|
- |
9.2 referes to IS 4826, Table 1(Uniformity of zinc coating- As per IS 2633 for Dia 3.15 to 3.55 mm For Soft Core) |
- |
2000 |
|
- |
9.2 referes to IS 4826, Table 1(Uniformity of zinc coating- As per IS 2633 for Dia 3.55 to 4.00 mm For Soft Core) |
- |
2000 |
|
- |
9.2 referes to IS 4826, Table 1(Uniformity of zinc coating- As per IS 2633 for Dia4.00 to5.00 mm For Soft Core) |
- |
2000 |
|
- |
9.2 referes to IS 4826, Table 1(Uniformity of zinc coating- As per IS 2633 for Dia 5.00 to 7.10 mm For Soft Core) |
- |
2000 |
|
- |
9.2 referes to IS 4826, Table 1(Uniformity of zinc coating- As per IS 2633 for Dia 7.10 to10.00 mm For Soft Core) |
- |
2000 |
|
- |
11(a) Size) |
- |
1000 |
|
- |
11(b) Construction) |
- |
1000 |
|
- |
11(c) tensile designation) |
- |
1000 |
|
- |
11(d) lay) |
- |
1000 |
|
- |
11(e) coating) |
- |
1000 |
|
- |
11(f) length) |
- |
1000 |
|
- |
11( g) mass) |
- |
1000 |
|
- |
11(h) manufacturer's name or trade mark) |
- |
1000 |
|
- |
11(i) lot number along with the order number) |
- |
1000 |
|
- |
11(j) BIS Standards Mark) |
- |
1000 |
|
- |
11(c) tensile designation) |
- |
1000 |
|
- |
11(d) lay) |
- |
1000 |
|
- |
11(e) coating) |
- |
1000 |
|
- |
11(f) length) |
- |
1000 |
|
- |
11( g) mass) |
- |
1000 |
|
- |
11(h) manufacturer's name or trade mark) |
- |
1000 |
|
- |
11(i) lot number along with the order number) |
- |
1000 |
|
- |
11(j) BIS Standards Mark) |
- |
1000 |
|
- |
5(a) Grade) |
- |
1000 |
|
- |
5(b) Tensile Grade) |
- |
1000 |
|
- |
6(a) Lay) |
- |
1000 |
|
- |
6(b) Construction) |
- |
1000 |
|
- |
7(Freedom from defects) |
- |
1000 |
|
- |
9(a) Tensile) |
- |
2000 |
|
- |
9(b) Elongation) |
- |
2000 |
|
- |
9(c) Galvanizing Test) |
- |
2000 |
|
- |
11(a) Size) |
- |
1000 |
|
- |
11(b) Construction) |
- |
1000 |
|
- |
5(a) Grade) |
- |
1000 |
|
- |
5(b) Tensile Grade) |
- |
1000 |
|
- |
6(a) Lay) |
- |
1000 |
|
- |
6(b) Construction) |
- |
1000 |
|
- |
7(Freedom from defects) |
- |
1000 |
|
- |
9(a) Tensile) |
- |
2000 |
|
- |
9(b) Elongation) |
- |
2000 |
|
- |
9(c) Galvanizing Test) |
- |
2000 |
|
- |
11(a) Size) |
- |
1000 |
|
- |
11(b) Construction) |
- |
1000 |
|
- |
11(c) tensile designation) |
- |
1000 |
|
- |
11(d) lay) |
- |
1000 |
|
- |
11(e) coating) |
- |
1000 |
|
- |
11(f) length) |
- |
1000 |
|
- |
11( g) mass) |
- |
1000 |
|
- |
11(h) manufacturer's name or trade mark) |
- |
1000 |
|
- |
11(i) lot number along with the order number) |
- |
1000 |
|
- |
11(j) BIS Standards Mark) |
- |
1000 |
|
- |
5(a) Grade) |
- |
1000 |
|
- |
5(b) Tensile Grade) |
- |
1000 |
|
- |
6(a) Lay) |
- |
1000 |
|
- |
6(b) Construction) |
- |
1000 |
|
- |
7(Freedom from defects) |
- |
1000 |
|
- |
9(a) Tensile) |
- |
2000 |
|
- |
9(b) Elongation) |
- |
2000 |
|
- |
9(c) Galvanizing Test) |
- |
2000 |
|
- |
9.2 referes to IS 4826, Table 1(Uniformity of zinc coating- As per IS 2633 for Dia 0.56 to 0.63 mm For Hard Core) |
- |
2000 |
|
- |
9.2 referes to IS 4826, Table 1(Uniformity of zinc coating- As per IS 2633 for Dia 0.63 to 0.71 mm For Hard Core) |
- |
2000 |
|
- |
9.2 referes to IS 4826, Table 1(Uniformity of zinc coating- As per IS 2633 for Dia 0.71 to 0.80 mm For Hard Core) |
- |
2000 |
|
- |
9.2 referes to IS 4826, Table 1(Uniformity of zinc coating- As per IS 2633 for Dia 0.80 to 0.90 mm) |
- |
2000 |
|
- |
9.2 referes to IS 4826, Table 1(Uniformity of zinc coating- As per IS 2633 for Dia 0.90 to 1.00 mm For Hard Core) |
- |
2000 |
|
- |
9.2 referes to IS 4826, Table 1(Uniformity of zinc coating- As per IS 2633 for Dia 1.00 to 1.25 mm For Hard Core) |
- |
2000 |
|
- |
9.2 referes to IS 4826, Table 1(Uniformity of zinc coating- As per IS 2633 for Dia 1.25 to1.40 mm For Hard Core) |
- |
2000 |
|
- |
9.2 referes to IS 4826, Table 1(Uniformity of zinc coating- As per IS 2633 for Dia 1.40 to1.60 mm For Hard Core) |
- |
2000 |
|
- |
9.2 referes to IS 4826, Table 1(Uniformity of zinc coating- As per IS 2633 for Dia2.00 to2.24 mm For Hard Core) |
- |
2000 |
|
- |
9.2 referes to IS 4826, Table 1(Mass of Zinc coating- as per IS 6745 for 5.00 to 7.10 mm dia For Soft Core) |
- |
2000 |
|
- |
9.2 referes to IS 4826, Table 1(Uniformity of zinc coating- As per IS 2633 for Dia 0.71 to 0.80 mm For Soft Core) |
- |
2000 |
|
- |
9.2 referes to IS 4826, Table 1(Uniformity of zinc coating- As per IS 2633 for Dia 1.40 to1.60 mm For Soft Core) |
- |
2000 |
|
- |
|
Complete
|
|
16 Apr, 2026 |
- - |
20 |
IS 12776 (2002) |
Galvanized strand for earthing - Specification (First Revision) |
- |
-
|
15000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
5.2(Freedom From Defects (IS 12776)) |
- |
1000 |
|
- |
5.3(Joints in wires (IS 12776)) |
- |
1000 |
|
- |
6- Annex-A, Sl-2(Size of the wire (IS 12776)) |
- |
1000 |
|
- |
6- Annex-A, Sl-8(Lay (IS 12776)) |
- |
1000 |
|
- |
8.1-Annex-A,Sl-9(Breaking Force of Strand (IS 12776)) |
- |
2000 |
|
- |
8.2-Annex-A,Sl-6(Elongation of wire, IS 10810(Part-37)) |
- |
2000 |
|
- |
8.2-Annex-A,Sl-3(Tensile Strength of wire IS 10810(Part-37)) |
- |
2000 |
|
- |
8.3-Annex-A,Sl-12(Resistance at 200 C (IS 12776)) |
- |
2000 |
|
- |
8.4(Wrapping Test (IS 12776)) |
- |
2000 |
|
- |
8.5-Annex-A-Sl-7a(Amount of zinc Coating (IS 6745)) |
- |
2000 |
|
- |
8.5-Annex-A-Sl-7b(Uniformity of Coating (IS 2633)) |
- |
2000 |
|
- |
8.5-Annex-A-Sl-4(Torsion Test IS 10810(Part-37)) |
- |
2000 |
|
- |
|
Complete
|
|
16 Apr, 2026 |
- - |
21 |
IS 398 : Part 4 (1994) |
Aluminium conductors for overhead transmission purposes: Part 4 aluminium alloy stranded conductors (Aluminium - Magnesium - Silicon Type) - Specification (Third Revision) |
- |
-
|
40000 View breakup
Rs. 3,500/- [15 sq. mm.], Rs. 10,000/-[22,
34, 55, 80 & 100 sq. mm.], Rs. 20,000/-
[125, 148, 173, 200 & 232 sq. mm.], Rs.
30,000/- [288, 346, 400 & 465 sq. mm.],
Rs. 40,000/-[525, 570, 604, 642, 695 &
767 sq. mm.]
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
6.1(Freedom from Defects) |
- |
1000 |
|
- |
7.1 Table-1(Dimensional measurement of wires) |
- |
1000 |
|
- |
7.2.2 Table-2, Table-4(Calculated resistance of Stranded Conductor) |
- |
2000 |
|
- |
8.1(Joints in wires-Conductors Containing Seven Wires) |
- |
1000 |
|
- |
8.2(Joints in wires-Conductors Containing More Than Seven Wires) |
- |
1000 |
|
- |
9.1(Stranding) |
- |
1000 |
|
- |
9.2 Table 3(Lay Ratio of stranded conductors) |
- |
1000 |
|
- |
9.3(Direction of Lay) |
- |
1000 |
|
- |
9.4(Multiple layers of wires) |
- |
1000 |
|
- |
11(Packing and Marking) |
- |
1000 |
|
- |
12.2 Table 1(Breaking Load Test- Before Stranding) |
- |
2000 |
|
- |
12.2 Table 1(Breaking Load Test- After Stranding) |
- |
2000 |
|
- |
12.3 Table 1(Elongation Test- Before Stranding) |
- |
2000 |
|
- |
12.3 Table 1(Elongation Test- After Stranding) |
- |
2000 |
|
- |
12.4 Table 1(Resistance of Aluminium wire) |
- |
2000 |
|
- |
9.2(Lay Ratio 24 wire layer) |
- |
1000 |
|
- |
9.2(Lay Ratio 18 wire layer) |
- |
1000 |
|
- |
9.2(Lay Ratio 12 wire layer) |
- |
1000 |
|
- |
9.2(Lay Ratio 3/6 wire layer) |
- |
1000 |
|
- |
|
Complete
|
|
16 Apr, 2026 |
- - |
22 |
IS 398 : Part 3 (1976) |
Specification for aluminium conductors for overhead transmission purposes: Part 3 aluminium conductors, aluminized steel reinforced (Second Revision) |
- |
-
|
20000 View breakup
Rs.6,200/- For 7 strands, Rs.8900/- For 13
strands, Rs.13,400/- For 37 strands,
Rs.15,000/- For 49 strands, Rs.20,000/-
For 61 strands.
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
12.6(Aluminizing Test) |
- |
2000 |
|
- |
7.2.2 Table 3(Resistance test-Aluminium wire Calculated Resistance) |
- |
2000 |
|
- |
12.5 Table 1(Resistance test-Aluminium wire after stranding) |
- |
2000 |
|
- |
12.5 Table 1(Resistance test-Aluminium wire before Stranding) |
- |
2000 |
|
- |
12.4.2(Wrapping TestAluminized Steel Wires After Stranding) |
- |
2000 |
|
- |
12.4.2(Wrapping Test Aluminized Steel Wires Before Stranding) |
- |
2000 |
|
- |
12.4.1(Wrapping Test Aluminium Wires After Stranding) |
- |
2000 |
|
- |
12.4.1(Wrapping Test Aluminium Wires Before Stranding) |
- |
2000 |
|
- |
12.3.2(Ductility by Elongation Test after stranding) |
- |
2000 |
|
- |
12.3.2(Ductility by Elongation Test before stranding) |
- |
2000 |
|
- |
12.3.1(Ductility by Torsion Test after stranding) |
- |
2000 |
|
- |
12.3.1(Ductility by Torsion Test after stranding) |
- |
2000 |
|
- |
12.3.1(Ductility by Torsion Test before stranding) |
- |
2000 |
|
- |
12.3.1(Ductility by Torsion Test before stranding) |
- |
2000 |
|
- |
12.2 Table 2(Breaking Load of aluminized steel wires After Stranding) |
- |
2000 |
|
- |
12.2 Table 1(Breaking Load of Aluminium Wires After Stranding) |
- |
2000 |
|
- |
12.2 Table 2(Breaking Load of aluminized steel wires Before Stranding) |
- |
2000 |
|
- |
12.2 Table 1(Breaking Load of Aluminium Wires Before Stranding) |
- |
2000 |
|
- |
9.5(STRANDING) |
- |
1000 |
|
- |
9.4(STRANDING) |
- |
1000 |
|
- |
9.3 Table 4(STRANDING) |
- |
1000 |
|
- |
9.2 Table 4(STRANDING : Lay Ratio For Steel Core) |
- |
1000 |
|
- |
9.2 Table 4(STRANDING : Lay Ratio For Aluminium Wire) |
- |
1000 |
|
- |
9.2 Table 4(STRANDING : Lay Ratio For Aluminium Wire) |
- |
1000 |
|
- |
9.2 Table 4(STRANDING : Lay Ratio For Aluminium Wire) |
- |
1000 |
|
- |
8.2(JOINTS IN WIRES : Aluminized Steel Wires) |
- |
1000 |
|
- |
8.1(JOINTS IN WIRES : Aluminium Wires) |
- |
1000 |
|
- |
7.1.2.2 Table 2(Diameter of Alumized Steel Wires After Stranding) |
- |
1000 |
|
- |
7.1.2.1 Table-1(Diameter of Aluminium Wires After Stranding) |
- |
1000 |
|
- |
7.1.2.2 Table 2(Diameter of Alumized Steel Wires Before Stranding) |
- |
1000 |
|
- |
7.1.2.1 Table-1(Diameter of Aluminium Wires Before Stranding) |
- |
1000 |
|
- |
|
Complete
|
|
16 Apr, 2026 |
- - |
23 |
IS 398 : Part 2 (1996) |
Aluminium conductors for overhead transmission purposes - Specification: Part 2 aluminium conuuctors, galvanized steel - Reinforced (Third Revision) |
- |
-
|
60000 View breakup
Type test: Rs. 10500/- [10, 18, 30, 50 & 80 sq. mm], Rs. 15500/- [100 sq. mm], Rs. 115000/- [ 150 & 200 sq. mm], Rs. 126000/- [400 & 560 sq. mm] & Rs. 146000/-[420 & 520 sq. mm.]; Restricted to (I) For galvanized steel core only (consisting of 7 steel strands)- Rs. 3,275/-,
(II) For galvanized steel reinforced stranded conductors with nominal aluminium area up to and including 100
sq. mm-(a) For single steel wire core (1 steel + 6 Aluminium)- Rs. 2,925/- (b) For 7 wire core (7 steel + 6 Aluminium) - Rs. 5,000/- (III) For galvanized steel
reinforced stranded conductors with nominal aluminium area more than 100 sq. mm (excluding special tests as per Cl. 13.9, 13.10 & 13.11)-(a) For stranded conductors with 37 strands- Rs. 10,850/-, (b) For stranded conductors with 49 strands-Rs.12000/- © for stranded
conductors with 61 strands-Rs. 14650/- for BIS Samples
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
8.1.1 & 13.2 Table-1 (mech)(Diameter of Aluminium Wires Before Stranding) |
- |
1000 |
|
- |
8.1.1 & 13.2 Table 2 (mech)(Diameter of Steel Wires Before Stranding) |
- |
1000 |
|
- |
8.1.1 & 13.2 Table-1 (mech)(Diameter of Aluminium Wires After Stranding) |
- |
1000 |
|
- |
8.1.1 & 13.2 Table 2 (mech)(Diameter of Steel Wires After Stranding) |
- |
1000 |
|
- |
10 (elec)(Stranding) |
- |
1000 |
|
- |
10 (elec)(Stranding) |
- |
1000 |
|
- |
10 (elec)(Stranding) |
- |
1000 |
|
- |
10 (mech)(Stranding) |
- |
1000 |
|
- |
13.3 Table 1 (mech)(Breaking Load of Aluminium Wires Before Stranding) |
- |
2000 |
|
- |
13.3 Table 2 (mech)(Breaking Load of Steel Wires Before Stranding) |
- |
2000 |
|
- |
13.3 Table 1 (mech)(Breaking Load of Aluminium Wires After Stranding) |
- |
2000 |
|
- |
13.3 Table 2 (mech)(Breaking Load of Steel Wires After Stranding) |
- |
2000 |
|
- |
13.4.1 (mech)(Ductility by Torsion Test before stranding) |
- |
2000 |
|
- |
13.4.1 (mech)(Ductility by Torsion Test before stranding) |
- |
2000 |
|
- |
13.4.1 (mech)(Ductility by Torsion Test after stranding) |
- |
2000 |
|
- |
13.4.1 (mech)(Ductility by Torsion Test after stranding) |
- |
2000 |
|
- |
13.4.2 (elec)(Ductility by Elongation Test before stranding) |
- |
2000 |
|
- |
13.4.2 (elec)(Ductility by Elongation Test after stranding) |
- |
2000 |
|
- |
13.5.1 (mech)(Wrapping Test Aluminium Wires Before Stranding) |
- |
2000 |
|
- |
13.5.1 (mech)(Wrapping Test Aluminium Wires After Stranding) |
- |
2000 |
|
- |
13.5.2 (mech)(Wrapping Test Galvanized Steel Wires Before Stranding) |
- |
2000 |
|
- |
13.5.2 (mech)(Wrapping Test Galvanized Steel Wires After Stranding) |
- |
2000 |
|
- |
13.6 (elec)(Resistance test-Aluminium wire before Stranding) |
- |
2000 |
|
- |
13.6 (elec)(Resistance test-Aluminium wire after stranding) |
- |
2000 |
|
- |
13.7.2 (chem)(Mass of Zinc coating) |
- |
2000 |
|
- |
13.7.2 (chem)(Uniformity of Zinc coating) |
- |
2000 |
|
- |
13.8 Table-4 (mech)(Lay Ratio- Aluminium Wire Outermost Layer) |
- |
1000 |
|
- |
13.8 Table-4 (mech)(Lay Ratio- Aluminium Wire Layer Immediately Beneath Outermost Layer) |
- |
1000 |
|
- |
13.8 Table-4 (mech)(Lay Ratio- Aluminium Wire Innermost Layer of Conductors with 3 Aluminium Wire Layers) |
- |
1000 |
|
- |
13.8 Table-4 (mech)(Lay Ratio- Steel Core (6 Wire Layer)) |
- |
1000 |
|
- |
13.9 (elec)(Surface condition test) |
- |
20000 |
|
- |
13.10 (elec)(Ultimate breaking load) |
- |
20000 |
|
- |
13.11 (elec)(Stress-strain test) |
- |
20000 |
|
- |
13.8 Table-4 (elec)(Lay Ratio- Steel Core (6 Wire Layer)) |
- |
1000 |
|
- |
13.8 Table-4 (elec)(Lay Ratio- Steel Core (6 Wire Layer)) |
- |
1000 |
|
- |
13.8 Table-4 (elec)(Lay Ratio- Aluminium Wire Innermost Layer of Conductors with 3 Aluminium Wire Layers) |
- |
1000 |
|
- |
13.8 Table-4 (elec)(Lay Ratio- Aluminium Wire Layer Immediately Beneath Outermost Layer) |
- |
1000 |
|
- |
13.8 Table-4 (elec)(Lay Ratio- Aluminium Wire Outermost Layer) |
- |
1000 |
|
- |
13.7.2 (elec)(Uniformity of Zinc coating) |
- |
2000 |
|
- |
13.7.2 (elec)(Mass of Zinc coating) |
- |
2000 |
|
- |
13.5.2 (elec)(Wrapping Test Galvanized Steel Wires After Stranding) |
- |
2000 |
|
- |
13.5.2 (elec)(Wrapping Test Galvanized Steel Wires Before Stranding) |
- |
2000 |
|
- |
13.5.1 (elec)(Wrapping Test Aluminium Wires After Stranding) |
- |
2000 |
|
- |
13.5.1 (elec)(Wrapping Test Aluminium Wires Before Stranding) |
- |
2000 |
|
- |
13.4.1 (elec)(Ductility by Torsion Test after stranding) |
- |
2000 |
|
- |
13.4.1 (elec)(Ductility by Torsion Test after stranding) |
- |
2000 |
|
- |
13.4.1 (elec)(Ductility by Torsion Test before stranding) |
- |
2000 |
|
- |
13.4.1 (elec)(Ductility by Torsion Test before stranding) |
- |
2000 |
|
- |
13.3 Table 2 (elec)(Breaking Load of Steel Wires After Stranding) |
- |
2000 |
|
- |
13.3 Table 1 (elec)(Breaking Load of Aluminium Wires After Stranding) |
- |
2000 |
|
- |
13.3 Table 2 (elec)(Breaking Load of Steel Wires Before Stranding) |
- |
2000 |
|
- |
13.3 Table 1 (elec)(Breaking Load of Aluminium Wires Before Stranding) |
- |
2000 |
|
- |
10 (elec)(Stranding) |
- |
1000 |
|
- |
8.1.1 & 13.2 Table 2 (elec)(Diameter of Steel Wires After Stranding) |
- |
1000 |
|
- |
8.1.1 & 13.2 Table-1 (elec)(Diameter of Aluminium Wires After Stranding) |
- |
1000 |
|
- |
8.1.1 & 13.2 Table 2 (elec)(Diameter of Steel Wires Before Stranding) |
- |
1000 |
|
- |
8.1.1 & 13.2 Table-1 (elec)(Diameter of Aluminium Wires Before Stranding) |
- |
1000 |
|
- |
|
Complete
|
|
16 Apr, 2026 |
- - |
24 |
IS 398 : Part 1 (1996) |
Aluminium conductors for overhead transmission purposes - Specification: Part 1 aluminium stranded conductors (Third Revision) |
- |
-
|
21000 View breakup
Rs.2100/- for 7 wire stands, Rs. 3250/- for
19 Strands, Rs.1000/- for Separated Wire
before Stranding (If provided)
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
12.2, Table-1(Measurement of diameter of individual aluminium wire) |
- |
1000 |
|
- |
12.3, Table-1(Breaking load before stranding) |
- |
2000 |
|
- |
12.3, Table-1(Breaking load after stranding) |
- |
2000 |
|
- |
12.4(Wrapping test) |
- |
2000 |
|
- |
12.5, Table 1(Resistance test) |
- |
2000 |
|
- |
12.6, Table 3(Measurement of lay ratio) |
- |
1000 |
|
- |
9.3(Stranding) |
- |
1000 |
|
- |
6(Freedom from defects) |
- |
1000 |
|
- |
|
Complete
|
|
16 Apr, 2026 |
- - |