1 |
IS 14855 : Part 1 (2000) |
Plant protection and vector control equipment - Fogging machines - Specification: Part 1 pulse - Jet - Type thermal fogger |
ALL |
-
|
56050 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
All(Requirements) |
- |
56050 |
|
Including GST |
All(Requirements) |
- |
56050 |
|
Including GST |
All(Requirements) |
- |
56050 |
|
Including GST |
Cl 4(MATERIALS) |
- |
3000 |
|
Excluding GST |
Cl 4(MATERIALS) |
- |
3000 |
|
Excluding GST |
Cl 5.1(General) |
- |
1500 |
|
Excluding GST |
Cl 5.1(General) |
- |
1500 |
|
Excluding GST |
Cl 5.2(Pump) |
- |
1000 |
|
Excluding GST |
Cl 5.2(Pump) |
- |
1000 |
|
Excluding GST |
Cl 5.3(Pulse-Jet Engine) |
- |
10000 |
|
Excluding GST |
Cl 5.3(Pulse-Jet Engine) |
- |
10000 |
|
Excluding GST |
Cl 5.5(Pesticide Tank) |
- |
1000 |
|
Excluding GST |
Cl 5.5(Pesticide Tank) |
- |
1000 |
|
Excluding GST |
Cl 5.6(Metering System) |
- |
4500 |
|
Excluding GST |
Cl 5.6(Metering System) |
- |
4500 |
|
Excluding GST |
Cl 5.7(Mounting Frame and Strap) |
- |
4000 |
|
Excluding GST |
Cl 5.7(Mounting Frame and Strap) |
- |
4000 |
|
Excluding GST |
Cl 6(PERFORMANCE REQUIREMENTS) |
- |
5000 |
|
Excluding GST |
Cl 6(PERFORMANCE REQUIREMENTS) |
- |
5000 |
|
Excluding GST |
Cl 7.1(Spare Parts and Tools) |
- |
500 |
|
Excluding GST |
Cl 7.1(Spare Parts and Tools) |
- |
500 |
|
Excluding GST |
Cl 7.2(Operation and Maintenance Manual) |
- |
500 |
|
Excluding GST |
Cl 7.2(Operation and Maintenance Manual) |
- |
500 |
|
Excluding GST |
Cl 7.3(Specification Sheet) |
- |
500 |
|
Excluding GST |
Cl 7.3(Specification Sheet) |
- |
500 |
|
Excluding GST |
Cl 8.2(Pulse-Jet Engine) |
- |
10000 |
|
Excluding GST |
Cl 8.2(Pulse-Jet Engine) |
- |
10000 |
|
Excluding GST |
Cl 8.3(Nozzle) |
- |
3500 |
|
Excluding GST |
Cl 8.3(Nozzle) |
- |
3500 |
|
Excluding GST |
Cl 8.4(Strap Test) |
- |
2500 |
|
Excluding GST |
Cl 8.4(Strap Test) |
- |
2500 |
|
Excluding GST |
All(Requirements) |
- |
56050 |
|
- |
All(Requirements) |
- |
56050 |
|
Including GST |
Cl 4(MATERIALS) |
- |
3000 |
|
Excluding GST |
Cl 4(MATERIALS) |
- |
3000 |
|
Excluding GST |
Cl 5.1(General) |
- |
1500 |
|
Excluding GST |
Cl 5.1(General) |
- |
1500 |
|
Excluding GST |
Cl 5.2(Pump) |
- |
1000 |
|
Excluding GST |
Cl 5.2(Pump) |
- |
1000 |
|
Excluding GST |
Cl 5.3(Pulse-Jet Engine) |
- |
10000 |
|
Excluding GST |
Cl 5.3(Pulse-Jet Engine) |
- |
10000 |
|
Excluding GST |
Cl 5.5(Pesticide Tank) |
- |
1000 |
|
Excluding GST |
Cl 5.5(Pesticide Tank) |
- |
1000 |
|
Excluding GST |
Cl 5.6(Metering System) |
- |
4500 |
|
Excluding GST |
Cl 5.6(Metering System) |
- |
4500 |
|
Excluding GST |
Cl 5.7(Mounting Frame and Strap) |
- |
4000 |
|
Excluding GST |
Cl 5.7(Mounting Frame and Strap) |
- |
4500 |
|
Excluding GST |
Cl 6(PERFORMANCE REQUIREMENTS) |
- |
5000 |
|
Excluding GST |
Cl 6(PERFORMANCE REQUIREMENTS) |
- |
5000 |
|
Excluding GST |
Cl 7.1(Spare Parts and Tools) |
- |
500 |
|
Excluding GST |
Cl 7.1(Spare Parts and Tools) |
- |
500 |
|
Excluding GST |
Cl 7.2(Operation and Maintenance Manual) |
- |
500 |
|
Excluding GST |
Cl 7.2(Operation and Maintenance Manual) |
- |
500 |
|
Excluding GST |
Cl 7.3(Specification Sheet) |
- |
500 |
|
Excluding GST |
Cl 7.3(Specification Sheet) |
- |
500 |
|
Excluding GST |
Cl 8.2(Pulse-Jet Engine) |
- |
10000 |
|
Excluding GST |
Cl 8.2(Pulse-Jet Engine) |
- |
10000 |
|
Excluding GST |
Cl 8.3(Nozzle) |
- |
3500 |
|
Excluding GST |
Cl 8.3(Nozzle) |
- |
3500 |
|
Excluding GST |
Cl 8.4(Strap Test) |
- |
2500 |
|
Excluding GST |
Cl 8.4(Strap Test) |
- |
2500 |
|
Excluding GST |
All(Requirements) |
- |
56050 |
|
- |
All(Requirements) |
- |
56050 |
|
- |
Cl 4(MATERIALS) |
- |
3000 |
|
- |
Cl 4(MATERIALS) |
- |
3000 |
|
- |
Cl 5.1(General) |
- |
1500 |
|
- |
Cl 5.1(General) |
- |
1500 |
|
- |
Cl 5.2(Pump) |
- |
1000 |
|
- |
Cl 5.2(Pump) |
- |
1000 |
|
- |
Cl 5.3(Pulse-Jet Engine) |
- |
10000 |
|
- |
Cl 5.3(Pulse-Jet Engine) |
- |
10000 |
|
- |
Cl 5.5(Pesticide Tank) |
- |
1000 |
|
- |
Cl 5.5(Pesticide Tank) |
- |
1000 |
|
- |
Cl 5.6(Metering System) |
- |
4500 |
|
- |
Cl 5.6(Metering System) |
- |
4500 |
|
- |
Cl 5.7(Mounting Frame and Strap) |
- |
4000 |
|
- |
Cl 5.7(Mounting Frame and Strap) |
- |
4000 |
|
- |
Cl 6(PERFORMANCE REQUIREMENTS) |
- |
5000 |
|
- |
Cl 6(PERFORMANCE REQUIREMENTS) |
- |
5000 |
|
- |
Cl 7.1(Spare Parts and Tools) |
- |
500 |
|
- |
Cl 7.1(Spare Parts and Tools) |
- |
500 |
|
- |
Cl 7.2(Operation and Maintenance Manual) |
- |
500 |
|
- |
Cl 7.2(Operation and Maintenance Manual) |
- |
500 |
|
- |
Cl 7.3(Specification Sheet) |
- |
500 |
|
- |
Cl 7.3(Specification Sheet) |
- |
500 |
|
- |
Cl 8.2(Pulse-Jet Engine) |
- |
10000 |
|
- |
Cl 8.2(Pulse-Jet Engine) |
- |
10000 |
|
- |
Cl 8.3(Nozzle) |
- |
3500 |
|
- |
Cl 8.3(Nozzle) |
- |
3500 |
|
- |
Cl 8.4(Strap Test) |
- |
2500 |
|
- |
Cl 8.4(Strap Test) |
- |
2500 |
|
- |
All(Requirements) |
- |
56050 |
|
including GST |
All(Requirements) |
- |
56050 |
|
including GST |
Cl 4(MATERIALS) |
- |
3000 |
|
excluding GST |
Cl 4(MATERIALS) |
- |
3000 |
|
excluding GST |
Cl 5.1(General) |
- |
1500 |
|
excluding GST |
Cl 5.1(General) |
- |
1500 |
|
excluding GST |
Cl 5.2(Pump) |
- |
1000 |
|
excluding GST |
Cl 5.2(Pump) |
- |
1000 |
|
excluding GST |
Cl 5.3(Pulse-Jet Engine) |
- |
10000 |
|
excluding GST |
Cl 5.3(Pulse-Jet Engine) |
- |
10000 |
|
excluding GST |
Cl 5.5(Pesticide Tank) |
- |
1000 |
|
excluding GST |
Cl 5.5(Pesticide Tank) |
- |
1000 |
|
excluding GST |
Cl 5.6(Metering System) |
- |
4500 |
|
excluding GST |
Cl 5.6(Metering System) |
- |
4500 |
|
excluding GST |
Cl 5.7(Mounting Frame and Strap) |
- |
4000 |
|
excluding GST |
Cl 5.7(Mounting Frame and Strap) |
- |
4000 |
|
excluding GST |
Cl 6(PERFORMANCE REQUIREMENTS) |
- |
5000 |
|
excluding GST |
Cl 6(PERFORMANCE REQUIREMENTS) |
- |
5000 |
|
excluding GST |
Cl 7.1(Spare Parts and Tools) |
- |
500 |
|
excluding GST |
Cl 7.1(Spare Parts and Tools) |
- |
500 |
|
excluding GST |
Cl 7.2(Operation and Maintenance Manual) |
- |
500 |
|
excluding GST |
Cl 7.2(Operation and Maintenance Manual) |
- |
500 |
|
excluding GST |
Cl 7.3(Specification Sheet) |
- |
500 |
|
excluding GST |
Cl 7.3(Specification Sheet) |
- |
500 |
|
excluding GST |
Cl 8.2(Pulse-Jet Engine) |
- |
10000 |
|
excluding GST |
Cl 8.2(Pulse-Jet Engine) |
- |
10000 |
|
excluding GST |
Cl 8.3(Nozzle) |
- |
3500 |
|
excluding GST |
Cl 8.3(Nozzle) |
- |
3500 |
|
excluding GST |
Cl 8.4(Strap Test) |
- |
2500 |
|
excluding GST |
Cl 8.4(Strap Test) |
- |
2500 |
|
excluding GST |
|
Complete
|
|
- |
- |
2 |
IS 14772 (2020) |
Boxes and Enclosures for Electrical Accessories for Household and Similar Fixed Electrical Installations — General Requirements ( First Revision ) |
- |
-
|
14000 View breakup
Type Test: Rs.14,000/-
Acceptance Test: Rs.10,500/-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
8.1(marking) |
- |
1800 |
|
1800 |
9.0(Dimensions) |
- |
1800 |
|
1800 |
10.0(Protection against electric shock) |
- |
1800 |
|
1800 |
11.0(PROVISION FOR EARTHING) |
- |
1800 |
|
1800 |
12.0(Constructions) |
- |
1800 |
|
1800 |
13.0(Resistance to ageing) |
- |
3000 |
|
3000 |
18.0(Resistance to insulating material to abnormal heat and fire) |
- |
3000 |
|
3000 |
13.0(Resistance to ingress of solid objects) |
- |
3500 |
|
3500 |
13.0(Resistance toharmful ingress of water) |
- |
3000 |
|
3000 |
15.0(Mechanical strength) |
- |
1800 |
|
1800 |
16.0(resistance to heat) |
- |
1800 |
|
1800 |
20.0(Resistance to corrosion) |
- |
1800 |
|
1800 |
19.0(Resistance to tracking) |
- |
1800 |
|
1800 |
|
Complete
|
|
- |
Included w.e.f. 24.01.2024 |
3 |
IS 694 (2010) |
Polyvinyl chloride insulated unsheathed and sheathed cables/cords with rigid and flexible conductor for rated voltages up to and including 450/750 v (Fourth Revision) |
PVC insulated unsheathed & sheathed cables/cords 110V |
-
|
12000 View breakup
Type Test:
Rs.12,000/- for Single Core/ Unsheathed/01;
Rs.16,000/- for Single Core/ Sheathed/01;
Rs.18,000/- for Single Core/ Unsheathed/FR;
Rs.22,000/- for Single Core/ Sheathed/FR;
Acceptance Test:
Rs.9,000/- for Single Core/ Unsheathed/01;
Rs.12,000/- for Single Core/ Sheathed/01;
Rs.13,500/- for Single Core/ Unsheathed/FR;
Rs.16,500/- for Single Core/ Sheathed/FR;
For multicore Cable:
25% extra for each additional core on single core rate.
For Cat. 02:
Rs.5,000/- additional on above test charge.
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
4.1(Tensile test (for Al)- After Stranding) |
- |
1800 |
|
Type test: i)Single core/Unsheathed/01:Rs.12,000/-, ii) Single core/sheathed/01:Rs.16000/- , iii)Single core/Unsheathed/FR:Rs.18000/-, iv)Single core/sheathed/FR:Rs.22000/- |
4.1(Tensile test (for Al)-Before Stranding) |
- |
1800 |
|
Acceptance test: i)Single core/Unsheathed/01:Rs.9,000/-, ii) Single core/sheathed/01:Rs.12000/- , iii)Single core/Unsheathed/FR:Rs.13500/-, iv)Single core/sheathed/FR:Rs.16500/- |
4.1(Annealing test (for copper)) |
- |
1800 |
|
For Multicore cables:25%extra for each additional core on single core rate |
4.1(Wrapping test (for Al)) |
- |
1500 |
|
- |
4.2(Conductor resistance test) |
- |
1800 |
|
- |
Table 1(Category Code) |
- |
5000 |
|
For Cat.02 Rs.5000/- additional on above test charge |
table 1 e) 3) (Volume Resistivity - Maximum temp) |
- |
1800 |
|
1800 |
table 1 e) 3) (IR constant- Room temp ) |
- |
1800 |
|
1800 |
table 1 e) 3) (IR constant- max. Temp) |
- |
1800 |
|
1800 |
5.1(Insulation) |
- |
2000 |
|
2000 |
Table 1 iii) d) 7)(Thermal stability- Sheath ) |
- |
1800 |
|
1800 |
Table 1 iii) d) 4)(Shrinkage- Sheath ) |
- |
3500 |
|
3500 |
Table 1 iii) c) 5)(Heat shock-Insulation ) |
- |
1800 |
|
1800 |
Table 1 iii) d) 6)(Hot deformation -Indentation depth - Sheath ) |
- |
2000 |
|
2000 |
Table 1 iii) d) 8)(Cold bend for sheath) |
- |
3500 |
|
3500 |
Table 1 iii) d) 9)(Cold impact for sheath) |
- |
3500 |
|
3500 |
10.4(Flammability test- Unaffected portion) |
- |
1800 |
|
1800 |
10.5(Oxygen index) |
- |
3500 |
|
3500 |
10.7(Temperature index) |
- |
3500 |
|
3500 |
Table 1 iii) d) 2)(Loss of mass- Sheath ) |
- |
3000 |
|
3000 |
Table 1 iii) d) 3)(Sheath- TS variation) |
- |
2000 |
|
2000 |
Table 1 iii) c) 4)(Shrinkage-Insulation) |
- |
3500 |
|
3500 |
Table 1 iii) d) 5)(Heat shock-Sheath ) |
- |
1800 |
|
1800 |
10.1(HV (water immersion)) |
- |
4000 |
|
4000 |
10.2(HV (room temperature)) |
- |
1800 |
|
1800 |
10.9(Additional ageing test (OU cables only) -HV test (at 60±3oC)) |
- |
5000 |
|
5000 |
|
Complete
|
|
- |
- |
4 |
IS 4250 (1980) |
Specification for domestic electric food - Mixers (Liquidizers And Grinders) (First Revision) |
Domestic Electric Food Mixers (Liquidizers & Grinders) |
-
|
14000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
7.1(Marking- IS 302-1) |
- |
1800 |
|
1800 |
8( Protection Against Electric Shock, IS 302-1) |
- |
1800 |
|
1800 |
9(Starting, IS 302-1) |
- |
1800 |
|
1800 |
10(Power Input and Current, IS 302-1) |
- |
1800 |
|
1800 |
11(Heating, IS 302-1) |
- |
2500 |
|
2500 |
13(Electrical Insulation and Leakage Current at Operating Temperature: Leakage current, IS 302-1) |
- |
1800 |
|
1800 |
15.1(Moisture Resistance, IS 302-1) |
- |
3000 |
|
3000 |
15.2(Moisture Resistance-Spillage test) |
- |
3000 |
|
3000 |
16(Electrical Insulation and Leakage Current at Operating Temperature: Leakage current, IS 302-1) |
- |
1800 |
|
1800 |
19(Abnormal Operation, IS 302-1) |
- |
1800 |
|
1800 |
21(Mechanical Strength, IS 302-1) |
- |
1800 |
|
1800 |
25(Supply Connection and External Flexible Cords, IS 302-1) |
- |
1800 |
|
1800 |
27(Provision for Earthing, IS 302-1) |
- |
1800 |
|
1800 |
28(Screws & Connections, IS 302-1) |
- |
1800 |
|
1800 |
29(Clearances and Distances through Insulation, IS 302-1) |
- |
1800 |
|
1800 |
30(Resistance to Heat, Fire, Tracking, IS 302-1) |
- |
3000 |
|
3000 |
34.2(Operational tests- Grinding coffee (for machines which have a dry grinding arrangement)) |
- |
2500 |
|
2500 |
34.3(Whisking egg whites ) |
- |
2500 |
|
2500 |
35(Temperature withstand test for bowl) |
- |
1500 |
|
1500 |
36(Test for controls ) |
- |
1800 |
|
1800 |
|
Complete
|
|
- |
Type Test: Rs.14,000/-
Acceptance Test: Rs.10,500/- |
5 |
IS 3854 (1997) |
Switches for domestic and similar purposes - Specification (Second Revision) |
Switches for Domestic & similar purpose |
-
|
9600 View breakup
Rs.9,600/- for 6AX/10A;
Rs.11,50/- for 16AX/20A;
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
6(Rating) |
- |
1800 |
|
Type test:Rs.14,000/- for 6AX/10A, Rs.16000/- for 16AX/20A for BIS SAMPLES Rs.7,462/- for 6AX/10A, Rs.8,775/- for 16AX/20A |
7(Classification) |
- |
1800 |
|
Type test:Rs.14,000/- for 6AX/10A, Rs.16000/- for 16AX/20A for BIS SAMPLES Rs.7,462/- for 6AX/10A, Rs.8,775/- for 16AX/20A |
10(Protection against Electric Shock) |
- |
1800 |
|
1800 |
11.1(Provision for earthing) |
- |
1800 |
|
1800 |
12(Terminals) |
- |
2500 |
|
2500 |
13.1(a) Insulating lining, barriers and the like [Cl 13.1]) |
- |
2500 |
|
2500 |
14(Mechanism [Cl. 14]) |
- |
3000 |
|
3000 |
15.1(Resistance to Ageing, to Harmful Ingress of water and to Humidity [Cl. 15]: Resistance to Ageing, [Cl. 15.1]) |
- |
3000 |
|
3000 |
16.1(Insulation resistance [Cl. 16.1]) |
- |
3000 |
|
3000 |
16.2( Electric Strength [Cl. 16.2]) |
- |
3000 |
|
3000 |
17(Temperature- rise [Cl. 17]) |
- |
2500 |
|
2500 |
18(Marking and breaking Capacity[Cl. 18]) |
- |
2000 |
|
2000 |
19(Normal Operation [Cl. 19] a) General & Operation) |
- |
4000 |
|
4000 |
19(b) Electric Strength) |
- |
1800 |
|
1800 |
19(c)Temperature-rise ) |
- |
4000 |
|
4000 |
20(Mechanical Strength Test [Cl. 20]) |
- |
1800 |
|
1800 |
21(Resistance to Heat [Cl.21]) |
- |
2500 |
|
2500 |
22(Screw, Current Carrying Part And Connection [Cl.22]) |
- |
1800 |
|
1800 |
23.2(Creepage distances, clearances and distance through sealing compound [Cl.23]) |
- |
1800 |
|
- |
19.2(Normal Operation (For AX type Switches) [Cl. 19.2]) |
- |
4000 |
|
- |
19.2(Normal Operation (For AX type Switches) [Cl. 19.2]) |
- |
4000 |
|
- |
24.1.1(Resistance to Abnormal Heat & Fire [Cl.24.1] [Glow Wire Test] [Cl.24.1.1]) |
- |
2500 |
|
- |
24.2(Resistance to tracking [For Switch other than ordinary] [Cl.24.2]) |
- |
1800 |
|
1800 |
24.2(Resistance to tracking [For Switch other than ordinary] [Cl.24.2]) |
- |
1800 |
|
- |
|
Complete
|
|
- |
- |
6 |
IS 16102 : Part 1 (2012) |
Self - Ballasted led lamps for general lighting services: Part 1 safety requirements |
Self ballasted LED Lamps for general lighting service |
-
|
20000 View breakup
Type Test : Rs.20,000/-
Acceptance Test: Rs.15,000/-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
5(Marking) |
- |
1800 |
|
1800 |
6(Interchangeability) |
- |
1800 |
|
1800 |
7(Protection against accidental contact with live parts) |
- |
1800 |
|
1800 |
8(Insulation Resistance and Electric Strength) |
- |
6000 |
|
6000 |
9(MECHANICAL STRENGTH) |
- |
2500 |
|
2500 |
10(cap temperature) |
- |
5000 |
|
5000 |
11(Resistance to Heat) |
- |
1800 |
|
1800 |
12(Resistance to Flame and Ignition) |
- |
2500 |
|
2500 |
13(Fault conditions) |
- |
1800 |
|
1800 |
14(Creepage distance and clearances) |
- |
1800 |
|
1800 |
|
Complete
|
|
- |
Lamp Cap Type : B22d only |
7 |
IS 1293 (2019) |
Plugs and socket - Outlets of rated Voltage up to and including 250 Volts and rated current up to and including 16 amperes - Specification (Third Revision) |
upto & including 250V & rated current upto 16A |
-
|
14000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
6(Ratings) |
- |
1800 |
|
Type Test:6A/10A:Rs.14000/-, 16A:Rs.16000/-, 6/16AMultiple Socket:Rs.20000/-
Acceptance Test:6A/10A:Rs.10500/-, 16A:Rs.12000/-, 6/16AMultiple Socket:Rs.15000/- |
7.1.1(Accessories Classification) |
- |
1800 |
|
Type Test:6A/10A:Rs.14000/-, 16A:Rs.16000/-, 6/16AMultiple Socket:Rs.20000/-
Acceptance Test:6A/10A:Rs.10500/-, 16A:Rs.12000/-, 6/16AMultiple Socket:Rs.15000/- |
7.1.2(Accessories Classification) |
- |
1800 |
|
1800 |
7.1.3(Accessories Classification) |
- |
1800 |
|
1800 |
7.1.4(Accessories Classification) |
- |
1800 |
|
1800 |
7.1.5(Accessories Classification) |
- |
1800 |
|
1800 |
7.2.1(Socket-Outlets Classification) |
- |
1800 |
|
1800 |
7.2.2(Socket-Outlets Classification) |
- |
1800 |
|
1800 |
7.2.3(Socket-Outlets Classification) |
- |
1800 |
|
1800 |
7.2.4(Socket-Outlets Classification) |
- |
1800 |
|
1800 |
7.3(Plug Classification) |
- |
1800 |
|
1800 |
8.1(MARKING) |
- |
1800 |
|
1800 |
8.8(MARKING) |
- |
1800 |
|
1800 |
8.9(MARKING) |
- |
1800 |
|
1800 |
9.1(CHECKING OF DIMENSIONS) |
- |
1800 |
|
1800 |
9.2(CHECKING OF DIMENSIONS) |
- |
1800 |
|
1800 |
10.1(PROTECTION AGAINST ELECTRIC SHOCK) |
- |
1800 |
|
1800 |
10.3(PROTECTION AGAINST ELECTRIC SHOCK) |
- |
1800 |
|
1800 |
10.4(PROTECTION AGAINST ELECTRIC SHOCK) |
- |
1800 |
|
1800 |
10.5(PROTECTION AGAINST ELECTRIC SHOCK) |
- |
1800 |
|
1800 |
10.6(PROTECTION AGAINST ELECTRIC SHOCK) |
- |
1800 |
|
1800 |
10.7(PROTECTION AGAINST ELECTRIC SHOCK) |
- |
1800 |
|
1800 |
11.1(PROVISIONS FOR EARTHING) |
- |
1800 |
|
1800 |
11.2(PROVISIONS FOR EARTHING) |
- |
1800 |
|
1800 |
11.3(PROVISIONS FOR EARTHING) |
- |
1800 |
|
1800 |
11.4(PROVISIONS FOR EARTHING) |
- |
1800 |
|
1800 |
11.5(PROVISIONS FOR EARTHING) |
- |
1800 |
|
1800 |
11.6(PROVISIONS FOR EARTHING) |
- |
1800 |
|
1800 |
12.1.1(TERMINALS) |
- |
2500 |
|
2500 |
12.1.2(TERMINALS) |
- |
2500 |
|
2500 |
12.2.1(TERMINALS) |
- |
2500 |
|
- |
12.2.2(TERMINALS) |
- |
2500 |
|
2500 |
12.2.3(TERMINALS) |
- |
2500 |
|
2500 |
12.2.4(TERMINALS) |
- |
2500 |
|
2500 |
12.2.5(TERMINALS) |
- |
2500 |
|
2500 |
12.2.6(TERMINALS) |
- |
2500 |
|
2500 |
12.2.7(TERMINALS) |
- |
2500 |
|
2500 |
12.2.8(TERMINALS) |
- |
2500 |
|
2500 |
12.2.9(TERMINALS) |
- |
2500 |
|
2500 |
12.2.10(TERMINALS) |
- |
2500 |
|
2500 |
12.2.11(TERMINALS) |
- |
2500 |
|
2500 |
12.3.1(TERMINALS) |
- |
2500 |
|
2500 |
12.3.2(TERMINALS) |
- |
2500 |
|
2500 |
12.3.4(TERMINALS) |
- |
2500 |
|
2500 |
12.3.5(TERMINALS) |
- |
2500 |
|
2500 |
12.3.6(TERMINALS) |
- |
2500 |
|
2500 |
12.3.7(TERMINALS) |
- |
2500 |
|
2500 |
12.3.8(TERMINALS) |
- |
2500 |
|
2500 |
12.3.9(TERMINALS) |
- |
2500 |
|
2500 |
12.3.10(TERMINALS) |
- |
2500 |
|
2500 |
12.3.11(TERMINALS) |
- |
2500 |
|
2500 |
12.3.12(TERMINALS) |
- |
2500 |
|
2500 |
13.1(CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
2500 |
|
2500 |
13.2(CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
2500 |
|
2500 |
13.3(CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
2500 |
|
2500 |
13.4(CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
2500 |
|
2500 |
13.5(CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
2500 |
|
2500 |
13.6(CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
2500 |
|
2500 |
13.7(CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
2500 |
|
2500 |
13.8(CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
2500 |
|
2500 |
13.9(CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
2500 |
|
2500 |
13.11(CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
2500 |
|
2500 |
13.12(CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
2500 |
|
2500 |
13.13(CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
2500 |
|
2500 |
13.14(CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
2500 |
|
2500 |
13.15(CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
2500 |
|
2500 |
13.16(CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
2500 |
|
2500 |
13.17(CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
2500 |
|
2500 |
13.18(CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
2500 |
|
2500 |
13.19(CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
2500 |
|
2500 |
13.21(CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
2500 |
|
2500 |
13.22(CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
2500 |
|
2500 |
13.23(CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
2500 |
|
2500 |
14.1(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
2500 |
|
2500 |
14.26(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
2500 |
|
2500 |
15(INTERLOCKED SOCKET-OUTLETS) |
- |
2500 |
|
2500 |
16.1(RESISTANCE TO AGEING,) |
- |
3000 |
|
3000 |
16.2(RESISTANCE TO HARMFUL INGRESS OF WATER AND TO HUMIDITY) |
- |
3000 |
|
3000 |
16.3(Resistance to Humidity) |
- |
3000 |
|
3000 |
17.1(INSULATION RESISTANCE AND ELECTRIC STRENGTH) |
- |
1800 |
|
1800 |
17.2(INSULATION RESISTANCE AND ELECTRIC STRENGTH) |
- |
1800 |
|
1800 |
17.3(INSULATION RESISTANCE AND ELECTRIC STRENGTH) |
- |
1800 |
|
1800 |
18(OPERATION OF EARTHING CONTACTS) |
- |
1800 |
|
1800 |
19(TEMPERATURE RISE) |
- |
2500 |
|
2500 |
20(BREAKING CAPACITY) |
- |
2000 |
|
2000 |
21(NORMAL OPERATION) |
- |
4000 |
|
4000 |
22.1(Verification of the Maximum Withdrawal Force) |
- |
1800 |
|
1800 |
22.2(Verification of Minimum Withdrawal Force) |
- |
1800 |
|
1800 |
23.1(FLEXIBLE CABLES AND THEIR CONNECTION) |
- |
1800 |
|
1800 |
23.3(FLEXIBLE CABLES AND THEIR CONNECTION) |
- |
1800 |
|
1800 |
24.1(MECHANICAL STRENGTH
For all kinds of fixed socket-outlets
) |
- |
1800 |
|
1800 |
24.2(MECHANICAL STRENGTH
For portable single socket-outlets:
1) with enclosures, covers or bodies other than thermoplastic or elastomeric material) |
- |
1800 |
|
1800 |
24.3(MECHANICAL STRENGTH
for fixed socket-outlets with a main part intended to be mounted directly on a surface) |
- |
1800 |
|
1800 |
24.4(MECHANICAL STRENGTH
For portable single socket-outlets:
1) with enclosures, covers or bodies of thermoplastic or elastomeric material) |
- |
1800 |
|
1800 |
24.5(MECHANICAL STRENGTH
For portable single socket-outlets:
1) with enclosures, covers or bodies of thermoplastic or elastomeric material) |
- |
1800 |
|
1800 |
24.6(MECHANICAL STRENGTH
For screwed glands of accessories having an IP code higher than IP20) |
- |
1800 |
|
1800 |
25.1(RESISTANCE TO HEAT
Accessories and surface mounting boxes) |
- |
2500 |
|
2500 |
25.2(RESISTANCE TO HEAT
Parts of insulating material necessary to retain
current-carrying parts of the earthing circuit in position,
as well as parts of the front surface zone of thermoplastic material) |
- |
2500 |
|
2500 |
25.3(RESISTANCE TO HEAT
Parts of insulating material not necessary to retain current-carrying parts and parts of the earthing circuit in position, even though they are in contact with them) |
- |
2500 |
|
2500 |
25.4(RESISTANCE TO HEAT
) |
- |
2500 |
|
2500 |
25.1(RESISTANCE TO HEAT
Accessories and surface mounting boxes) |
- |
2500 |
|
2500 |
26.1(SCREWS, CURRENT-CARRYING PARTS AND CONNECTIONS) |
- |
1800 |
|
1800 |
26.2(SCREWS, CURRENT-CARRYING PARTS AND CONNECTIONS) |
- |
1800 |
|
1800 |
27.1(CREEPAGE DISTANCES, CLEARANCES AND DISTANCES THROUGH SEALING COMPOUND) |
- |
1800 |
|
1800 |
27.2(CREEPAGE DISTANCES, CLEARANCES AND DISTANCES THROUGH SEALING COMPOUND) |
- |
1800 |
|
1800 |
28.1.1(Resistance to Abnormal Heat and to Fire
Glow-Wire Test) |
- |
2500 |
|
2500 |
28.1.2(Resistance to Abnormal Heat and to Fire
for plugs with pins provided with insulating sleeves) |
- |
2500 |
|
2500 |
28.2(Resistance to Tracking
For accessories other than IP code higher than IPX0 parts of insulating material retaining live parts in position) |
- |
2500 |
|
2500 |
29(RESISTANCE TO RUSTING) |
- |
1800 |
|
1800 |
30.1(ADDITIONAL TESTS ON PINS PROVIDED WITH INSULATING SLEEVES
Pressure Test at High Temperature) |
- |
1800 |
|
1800 |
30.2(ADDITIONAL TESTS ON PINS PROVIDED WITH INSULATING SLEEVES
Static Damp Heat Test) |
- |
1800 |
|
1800 |
30.3(ADDITIONAL TESTS ON PINS PROVIDED WITH INSULATING SLEEVES
Tests at Low Temperature) |
- |
1800 |
|
1800 |
30.4(ADDITIONAL TESTS ON PINS PROVIDED WITH INSULATING SLEEVES
Impact Test at Low Temperature) |
- |
1800 |
|
1800 |
|
Complete
|
|
- |
- |
8 |
IS 14927 : Part 2 (2001) |
Cable Trunking and Ducting Systems for Electrical Installations : Part 2 Cable Trunking and Ducting Systems Intended for Mounting on Walls or Ceiling |
1 |
-
|
12000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
7.1(Marking (as per Cl 7.1 of IS:14927(Pt-I ):2001)) |
- |
1000 |
|
1000 |
7.2(Marking (as per Cl 7.2 of IS:14927(Pt-I ):2001)) |
- |
1000 |
|
1000 |
8.1( Dimensions (As per cl.8.1 of IS 14927(Pt-1) : 2001)) |
- |
1000 |
|
1000 |
8.2(Dimensions (As per cl.8.2 of IS 14927(Pt-1) : 2001) |
- |
1000 |
|
1000 |
8.3, table 2( Dimensions (As per cl.8.3 and Table-2 of IS 14927(Pt-1) : 2001)) |
- |
1000 |
|
1000 |
9.1(Construction) |
- |
2000 |
|
2000 |
9.2(Construction ( As per Cl. 9.2 of IS 14927(Pt-1):2001)) |
- |
2000 |
|
2000 |
9.3(Construction ( As per Cl. 9.3 of IS 14927(Pt-1):2001)) |
- |
2000 |
|
2000 |
9.4.1(Construction [Access to Live Parts (As per Cl. 9.4.1 of IS 14927(Pt-1):2001)]) |
- |
2000 |
|
2000 |
9.5(Construction (As per Cl. 9.5 of IS 14927(Pt-1):2001)) |
- |
2000 |
|
2000 |
9.6.2(Construction [Membranes (As per Cl.9.6.2 of IS: 14927 (Pt-1):2001)]) |
- |
2000 |
|
2000 |
9.6.4(Construction [Membranes (As per Cl.9.6.4 of IS: 14927 (Pt-1):2001)]) |
- |
2000 |
|
2000 |
9.7.2, table 4(Construction [Glands (As per Cl.9.7.2 and Table-4 of IS: 14927 (Pt-1):2001)] ) |
- |
2000 |
|
2000 |
10.2(Cable supporting test for Surface mounting (As per Cl.10.2)) |
- |
2000 |
|
2000 |
10.3(Impact Test [ Cl.10.3 ]) |
- |
2000 |
|
2000 |
10.4(Linear Deflection Test [ Cl.10.4 ]) |
- |
2000 |
|
2000 |
11.1.1(Resistance to flame propagation (As per Cl. 11.1.1)) |
- |
1000 |
|
1000 |
12(Electrical Insulating Strength and Insulation Resistance Test. [ Cl.12.3 ]) |
- |
3000 |
|
3000 |
10.2(Cable supporting test for Surface mounting (As per Cl.10.2)) |
- |
2000 |
|
2000 |
|
Complete
|
|
- |
- |
9 |
IS 9537 : Part 3 (1983) |
Specification for conduits for electrical installations: Part 3 rigid plain conduits of insulating meterials |
- |
-
|
4950 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
8.1(Construction as per clause 8 of IS: 9537 (Part 1)-1980) |
- |
1000 |
|
Rs.14,000/- for BIS Samples Rs.4950/- for upto and including 25mm, Rs.4,275/- for above 25mm |
6.1(Marking) |
- |
1000 |
|
Rs.14,000/- for BIS Samples Rs.4950/- for upto and including 25mm, Rs.4,275/- for above 25mm |
6.2(Durability of Marking as per 6.4 of IS: 9537 (Part 1)-1980) |
- |
1000 |
|
1000 |
7.1.1(Maximum and minimum outside diameter of socket) |
- |
1000 |
|
1000 |
7.1.1 Table-2(Length of Socket end) |
- |
1000 |
|
1000 |
7.1.2(Maximum and minimum outside diameter of conduit) |
- |
1000 |
|
1000 |
7.2(Minimum inside diameter of conduit) |
- |
1000 |
|
1000 |
7.3(Length of conduit) |
- |
1000 |
|
1000 |
7.4(Unifomity of The wall Thickness) |
- |
1000 |
|
1000 |
9.2(Bending Test i) At Room Temp ii) At Low Temp (-5 ±2°C)) |
- |
2000 |
|
2000 |
9.3(Compression Test as per caluse 9.3 of IS: 9537 (Part 1)-1980) |
- |
2000 |
|
2000 |
9.4(Impact Test as per clause 9.4 of IS: 9537 (Part 1)-1980) |
- |
2000 |
|
2000 |
9.5(Collapse Test as per clause 9.5 of IS: 9537 (Part 1)-1980) |
- |
2000 |
|
2000 |
10(Resistance to Heat -Ball presure test) |
- |
2000 |
|
2000 |
11(Resistance to burning as per clause 11 of IS: 9537 (Part 1)-1980) |
- |
1000 |
|
1000 |
12(Electrical Characteristics-Test for electric strength as per clause 12.1.1 of IS: 9537 (Part 1)-1980) |
- |
3000 |
|
3000 |
12(Electrical Characteristics-Insulation resistance test as per clause 12.1.2 of IS: 9537 (Part 1)-1980) |
- |
3000 |
|
3000 |
|
Complete
|
|
- |
- |
10 |
IS 3419 (1988) |
Specification for fittings for rigid non - Metallic (Second Revision) |
- |
-
|
10000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
8 & 5(Visual Examination -IS:3419) |
- |
1000 |
|
1000 |
6.2 & 9.1- Table-1, ii(Inside Diameter of Collar for Slip type cuplers -IS:3419) |
- |
2000 |
|
2000 |
6.2 & 9.1- Table-1, iii(Inside Diameter of Ridge for Slip type cuplers -IS:3419) |
- |
2000 |
|
2000 |
6.2 & 9.1- Table-1, iv(Minimum overall length for Slip type cuplers -IS:3419) |
- |
2000 |
|
2000 |
6.2 & 9.1- Table-1, v(Minimum wall thickness for Slip type cuplers -IS:3419) |
- |
2000 |
|
2000 |
6.2 & 9.1- Table-2, ii(Inside Diameter of Collar for Socketed type cuplers -IS:3419) |
- |
2000 |
|
2000 |
6.2 & 9.1- Table-2, iii(Inside Diameter of Ridge for Socketed type cuplers -IS:3419) |
- |
2000 |
|
2000 |
6.2 & 9.1- Table-2, iv(Minimum overall length (a) for Socketed type cuplers -IS:3419) |
- |
2000 |
|
2000 |
6.2 & 9.1- Table-2, v(Minimum overall length (l) for Socketed type cuplers -IS:3419) |
- |
2000 |
|
2000 |
6.2 & 9.1- Table-2, vi(Minimum wall thickness for Socketed type cuplers -IS:3419) |
- |
2000 |
|
2000 |
6.2 & 9.1- Table-3, ii(Inside Diameter of Collar(d6) for Clamp type cuplers -IS:3419) |
- |
2000 |
|
2000 |
6.2 & 9.1- Table-3, iv(Inside Diameter of Ridge for Clamp type cuplers -IS:3419) |
- |
2000 |
|
2000 |
6.2 & 9.1- Table-3, iv(Minimum length for Clamp type cuplers -IS:3419) |
- |
2000 |
|
2000 |
6.2 & 9.1- Table-4, v(Length (l1) of Normal Type Bend -IS:3419) |
- |
2000 |
|
2000 |
6.2 & 9.1- Table-3, vi(Minimum wall thickness for Clamp type cuplers -IS:3419) |
- |
2000 |
|
2000 |
6.2 & 9.1- Table-4, ii(Outside Dameter of Normal type bend -IS:3419) |
- |
2000 |
|
2000 |
6.2 & 9.1- Table-4, iii(Minimum Inside Diameter of Normal Type Bend -IS:3419) |
- |
2000 |
|
2000 |
6.2 & 9.1- Table-4, iv(Radious(R) of Normal Type Bend -IS:3419) |
- |
2000 |
|
2000 |
6.2 & 9.1- Table-5, ii(Outside Dameter of Slip type cupling bend -IS:3419) |
- |
2000 |
|
2000 |
6.2 & 9.1- Table-5, iii(Minimum Inside Diameter of Slip type cupling bend -IS:3419) |
- |
2000 |
|
2000 |
6.2 & 9.1- Table-5, iv(Inside Diameter of collar for Slip type cupling bend -IS:3419) |
- |
2000 |
|
2000 |
6.2 & 9.1- Table-5, v(R- for Slip type cupling bend -IS:3419) |
- |
2000 |
|
2000 |
6.2 & 9.1- Table-5, vi(Y- for Slip type cupling bend -IS:3419) |
- |
2000 |
|
2000 |
6.2 & 9.1- Table-5, vii(l2- for Slip type cupling bend -IS:3419) |
- |
2000 |
|
2000 |
6.2 & 9.1- Table-6, ii(Inside Diameter of collar for Normal type Elbows -IS:3419) |
- |
2000 |
|
2000 |
6.2 & 9.1- Table-6, iii(Length (l) of Normal Type Elbows -IS:3419) |
- |
2000 |
|
2000 |
6.2 & 9.1- Table-6, iv(Radious(r) of Normal Type Elbows -IS:3419) |
- |
2000 |
|
2000 |
6.2 & 9.1- Table-6, v(Minimum wall thicknes of Elbows -IS:3419) |
- |
2000 |
|
2000 |
6.2 & 9.1- Table-7, ii(Inside Diameter of Collear for Normal type Tees -IS:3419) |
- |
2000 |
|
2000 |
6.2 & 9.1- Table-7, iii(Length (l) of Normal type Tees -IS:3419) |
- |
2000 |
|
2000 |
6.2 & 9.1- Table-7, iv(Radious(r) of Normal type Tees -IS:3419) |
- |
2000 |
|
2000 |
6.2 & 9.1- Table-7, v( Minimum wall thicknes of Normal type Tees -IS:3419) |
- |
2000 |
|
2000 |
6.2 & 9.1- Table-8, ii(Inside Diameter of Collear for socketed type Tees - IS:3419) |
- |
2000 |
|
2000 |
6.2 & 9.1- Table-8, iii(a - of socketed type Tees -IS:3419) |
- |
2000 |
|
2000 |
6.2 & 9.1- Table-8, iv(l - of socketed type Tees -IS:3419) |
- |
2000 |
|
2000 |
6.2 & 9.1- Table-8, v(Minimum wall thicknes of socketed type Tees -IS:3419) |
- |
2000 |
|
2000 |
6.2 & 9.1- Table-9, ii(B - of spout Type Circular Boxes -IS:3419) |
- |
2000 |
|
2000 |
6.2 & 9.1- Table-9, iii(C - of spout Type Circular Boxes -IS:3419) |
- |
2000 |
|
2000 |
6.2 & 9.1- Table-9, iv(D - of spout Type Circular Boxes -IS:3419) |
- |
2000 |
|
2000 |
6.2 & 9.1- Table-9, v(E - of spout Type Circular Boxes -IS:3419) |
- |
2000 |
|
2000 |
6.2 & 9.1- Table-9, vi(F(Max) - of spout Type Circular Boxes -IS:3419) |
- |
2000 |
|
2000 |
6.2 & 9.1- Table-9, vii(F(Min) - of spout Type Circular Boxes -IS:3419) |
- |
2000 |
|
2000 |
6.2 & 9.1- Table-9, viii(G - of spout Type Circular Boxes -IS:3419) |
- |
2000 |
|
2000 |
6.2 & 9.1- Table-9, ix(t - of spout Type Circular Boxes -IS:3419) |
- |
2000 |
|
2000 |
10(Resistance to Heat -IS:3419) |
- |
2000 |
|
2000 |
11(Resistance to Burning - IS 3419) |
- |
2000 |
|
2000 |
12(Moisture Absorption - IS 3419) |
- |
2000 |
|
2000 |
13.2 &13.3(Resistance to chemival action in Acid solution - IS 3419) |
- |
2000 |
|
2000 |
13.2 &13.3(Resistance to chemival action in Alkaline solution - IS 3419) |
- |
2000 |
|
2000 |
14.1(Copper Test - IS 3419) |
- |
2000 |
|
2000 |
15, 15.3(Resistance to Oil - IS 3419) |
- |
2000 |
|
2000 |
15,15.4(Resistance to Oil - IS 3419) |
- |
2000 |
|
2000 |
16- Appendix-A(Resistance to Impact -IS 3419) |
- |
2000 |
|
2000 |
17.2(Electric Strength - IS 3419) |
- |
2000 |
|
2000 |
17.3(Insulation Resistance - IS 3419) |
- |
2000 |
|
2000 |
|
Complete
|
|
- |
- |
11 |
IS 7231 (1994) |
plastic flushing cisterns for waterclosets and urinals |
Discharge capacity from 5liter to 10liter |
-
|
10500 View breakup
Rs.10,500/- + taxes
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Cl 5.1(Cistern) |
- |
2000 |
|
2000 |
Cl 5.2(Cover) |
- |
2000 |
|
2000 |
Cl 5.3(Flush pipe) |
- |
2000 |
|
2000 |
Cl 5.3.1(Flush pipe connection to cistern.) |
- |
2000 |
|
2000 |
Cl 5.4(Inlet and overflow holes) |
- |
2000 |
|
2000 |
Cl 5.5(Float valve) |
- |
2000 |
|
2000 |
Cl 5.6(Operating mechanism / lever) |
- |
2000 |
|
2000 |
(Cl.6)(Finish) |
- |
1000 |
|
1000 |
(Cl 9.3)(Endurance test) |
- |
5000 |
|
5000 |
Cl 7.6 & 9.2(Discharge rate ) |
- |
1000 |
|
1000 |
|
Complete
|
|
- |
- |
12 |
IS 12592 (2002) |
Precast concrete manhole cover and frame - Specification (First Revision) |
LD-2.5, MD-10,HD-20, EHD-35 |
-
|
9000.00 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
5.2 and Table 1(Dimensions of Frame - A) |
- |
500 |
|
Per single dim.500 |
5.2 and Table 1(Dimensions of Frame - B) |
- |
500 |
|
Per single dim.500 |
5.2 and Table 1(Dimensions of Frame - C) |
- |
500 |
|
Per single dim.500 |
5.2 and Table 1(Dimensions of Frame - D) |
- |
500 |
|
Per single dim.500 |
5.2 and Table 1(Dimensions of Frame - E) |
- |
500 |
|
Per single dim.500 |
5.2 and Table 1(Dimensions of Frame - F) |
- |
500 |
|
Per single dim.500 |
5.2(Dimensions of cover- Diameter) |
- |
500 |
|
Per single dim.500 |
5.2(Clearance at top between the frame and the cover all round the periphery) |
- |
500 |
|
Per single dim.500 |
5.2(Top surface ofthe frame and cover is in level) |
- |
500 |
|
Per single dim.500 |
5.2(Suitable taper matching with taper given for the frame shall be provided to the periphery of the cover) |
- |
500 |
|
Per single dim.500 |
5.2 and Fig 1(Clear cover to reinforcement) |
- |
500 |
|
Per single dim.500 |
5.2 and Fig 1(Distance of housing from the edge) |
- |
500 |
|
Per single dim.500 |
7.4.1(Edge Protection and Finishing - Frame) |
- |
1500 |
|
1500 |
7.4.2(Edge Protection and Finishing - Cover) |
- |
1500 |
|
1500 |
8(LIFTING HOOKS) |
- |
500 |
|
Per single dim.500 |
9.3 and Table and
Annex C(Load Test) |
- |
2500 |
|
2500 |
|
Complete
|
|
- |
- |
13 |
IS 651 (2007) |
Glazed stoneware pipes and fittings - Specification (Sixth Revision) |
Class: SP1, SP2 & SP3 |
-
|
9500 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
5.1(GENERAL QUALITY) |
- |
500 |
|
Visual inspection |
7.2(Hydraulic Test) |
- |
2500 |
|
Hydraulic Test |
7.3(Absorption Test) |
- |
1500 |
|
Absorption Test |
Clause 7.4(Acid Resistance Test) |
- |
1000 |
|
Test for Acid Resistance |
Clause 7.5(Alkali Resistance Test) |
- |
1000 |
|
Test for Alkali Resistance |
|
Complete
|
|
- |
- |