CENTRAL POWER RESEARCH INSTITUTE NOIDA

Regional Testing Laboratory, Plot No.-3A, Intuitional Area, Sector-62, Noda, Noida, Gautam Buddha Nagar, Uttar Pradesh, 201309
9810803435 jaiswal@cpri.in
Scope List
Reset
9 Results
S.No. Indian Standard No. Product Grade / Type / Size / Designation etc. Exclusion Testing Charges (Excl. Of Taxes) Facility Type Effective Date Validity Date Remark
1 IS 15959 (Part 1) : 2011 (2011) Data exchange for electricity meter - Reading, tariff and load control - Companion specification - - 130250 View breakup
-
Complete - 3 PH 4 w METER
2 IS 16444 : Part 2 (2017) AC static transformer operated watthour and var - Hour smart meters, class 0.2 S, 0.5 S and 1.0 S: Part 2 specification transformer operated smart meters - - 623530 View breakup
-
Complete - Exclusion: Cl.6.2.1 (Hed Deflectoin test)
3 IS 16444 (2015) AC static direct connected watthour smart meter class 1 and 2 - Specification - - 583620 View breakup
-
Complete - Exclusion: Cl. 7.2, 10.4 (Dielectric strength (G-8)), Cl. 7.2, 10.4 (Minimum switched current (G-7)), (Short circuit current carrying capacity (G-6)), (Fault current making capacity (G-5)), (Line to load voltage surge withstand (G-4)), (Electrical endurance (G-3)), (Normal operation (G-2)), Cl. 6.2.1 (Heat Deflection Test), Cl. 6.11, Electromagnetic Compatibility Radiated Emission test for frequency range above 30 MHz (Cl.5.5.5 of IS 15884)
4 IS 15959 : Part 3 (2017) Data exchange for electricity meter reading, tariff and load control - Companion specification: Part 3 smart meter (Transformer Operated KWh And KVarh, Class 0.2 S, 0.5 S And 1.0 S) Data exchange for electricity meter reading, tariff - 150500 View breakup
-
Complete - -
5 IS 15959 : Part 2 (2016) Data exchange for electricity meter reading, tarif and load control - Companion specification: Part 2 smart meter 3 PH 4 w METER - 150500 View breakup
-
Complete - -
6 IS 14697 (2021) ac STATIC TRANSFORMER OPERATED WATTHOUR METERS CLASS 02 S AND 05 S AND VAR-HOUR METERS CLASS 02 S 05 S AND 10 S - SPECIFICATION First Revision 3 PH 4 w LTCT METER - 269330 View breakup
-
Complete - 3 PH 4 w LTCT METER
7 IS 7098 : Part 1 (1988) Specification for crosslinked polyethylene insulated pvc sheathed cables: Part 1 for working voltages up to and including 1100 volts (First Revision) Specification for crosslinked polyethylene insulated pv - 290000 View breakup
-
Complete - -
8 IS 13779 (2020) ac STATIC WATTHOUR METERS CLASS 1 AND 2-Specefication 1 PH 2W STATIC WATTHOUR METERS CLASS 1 AND 2-Speceficat - 205640 View breakup
-
Complete - 1 PH 2W STATIC WATTHOUR METERS CLASS 1 AND 2
9 IS 1180 : Part 1 (2014) Outdoor Type Oil Immersed Distribution Transformers Upto and Including 2 500 kVA, 33kV - Specification Part 1 Mineral Oil Immersed (Fourth Revision) - - 212050 View breakup
-
Complete - Exclusion: Cl.21.3(c) (Short-circuit withstand test), Cl. 17 ( ABILITY OF TRANSFORMERS TO WITHSTAND EXTERNAL SHORT CIRCUIT), Cl. 21.4 b (Short-circuit withstand test IS 2026 (Part 5) (above 200 kVA))

Designed, Developed and Maintained by:

Arohatech IT Services (P) Ltd.