4.1(CONDUCTOR) |
- |
0 |
|
- |
4.1.1(CONDUCTOR) |
- |
0 |
|
- |
5(INSULATION) |
- |
0 |
|
Complete testing Charge :
Rs.1,90,000/- for Single core cable; Rs.2,40,000/- for Three core cable up to 19/33 kV.
and Rs.4,20,000/- for Single core cable; Rs.6,25,000/- for Three core cable for 33/33 kV. |
6(SCREENING) |
- |
0 |
|
- |
6.1.1(SCREENING : - Non-metallic — Semiconducting Compound) |
- |
0 |
|
- |
6.1.2(SCREENING : - Non-magnetic Metallic Tape for Single Core Unscreened and Unarmoured Cables) |
- |
0 |
|
- |
7(FILLERS AND INNER SHEATH) |
- |
0 |
|
- |
8.1(ARMOURING) |
- |
0 |
|
- |
8.2(ARMOURING) |
- |
0 |
|
- |
9(OUTER SHEATH ) |
- |
0 |
|
- |
10.1(CONDUCTOR) |
- |
0 |
|
- |
10.2(CONDUCTOR) |
- |
0 |
|
- |
11(CONDUCTOR SCREENING) |
- |
0 |
|
- |
12.1(INSULATION) |
- |
0 |
|
- |
12.2(INSULATION : Thickness of Insulation) |
- |
2500 |
|
- |
12.3(INSULATION : Tolerance on Thickness of Insulation) |
- |
0 |
|
- |
12.4(Eccentricity and Ovality) |
- |
2500 |
|
- |
12.5(INSULATION : Application of Insulation) |
- |
0 |
|
- |
13.1(INSULATION SCREENING) |
- |
0 |
|
- |
13.2(INSULATION SCREENING) |
- |
0 |
|
- |
13.3(INSULATION SCREENING) |
- |
0 |
|
- |
13.4(INSULATION SCREENING) |
- |
0 |
|
- |
14.1(CORE IDENTIFICATION) |
- |
25000 |
|
Additional Charge, Rs 25000/- for each additional Core |
14.1.1(CORE IDENTIFICATION) |
- |
0 |
|
- |
15.1(LAVING UP OF CORES) |
- |
0 |
|
- |
16.1(INNER SHEATH (COMMON COVERING)) |
- |
0 |
|
- |
16.2(INNER SHEATH (COMMON COVERING)) |
- |
0 |
|
- |
16.2.1(INNER SHEATH (COMMON COVERING)) |
- |
0 |
|
- |
16.3(INNER SHEATH (COMMON COVERING) : Thickness of Inner Sheath) |
- |
500 |
|
- |
16.3.1(INNER SHEATH (COMMON COVERING) : Thickness of Inner Sheath) |
- |
0 |
|
- |
17.1(ARMOURING : Application ) |
- |
0 |
|
- |
17.1.1(ARMOURING ) |
- |
0 |
|
- |
17.1.2(ARMOURING ) |
- |
0 |
|
- |
17.1.3(ARMOURING ) |
- |
0 |
|
- |
17.2(ARMOURING : Type of armour ) |
- |
0 |
|
- |
17.2.1(ARMOURING : Type of armour ) |
- |
0 |
|
- |
17.2(ARMOURING : Coverage ) |
- |
1500 |
|
- |
17.3(ARMOURING : Dimension ) |
- |
1000 |
|
- |
17.4(ARMOURING : Joints) |
- |
0 |
|
- |
16.4(ARMOURING : Resistance) |
- |
3500 |
|
- |
18.1(OUTER SHEATH) |
- |
0 |
|
- |
18.2(OUTER SHEATH: Colour) |
- |
0 |
|
- |
18.3(Thicknes of outer sheath : average ) |
- |
500 |
|
- |
18.3(Thicknes of outer sheath : minimum ) |
- |
0 |
|
- |
19.1 i) a)(Annealing test (for copper)) |
- |
2500 |
|
Charge, as applicable |
19.1 i) b)(Tensile test (for aluminium) - Before stranding ) |
- |
2500 |
|
Charge, as applicable |
19.1 i) b)(Tensile test (for aluminium) - After stranding ) |
- |
0 |
|
- |
19.1 i) c)(Wrapping test ( for aluminium)) |
- |
0 |
|
- |
19.1 i) d)(Resistance test - Main conductor ) |
- |
3500 |
|
- |
19.1 i) d)(Resistance test - Neutral conductor ) |
- |
0 |
|
- |
19.1 iii) a)(Phyaical tests for insulation : Tensile Test) |
- |
1500 |
|
- |
19.1 iii) a)(Phyaical tests for insulation : Elongation ) |
- |
1000 |
|
- |
19.1 iii) b)(Phyaical tests for insulation - Ageing in air Oven : Tensile Variation ) |
- |
2500 |
|
- |
19.1 iii) b)(Phyaical tests for insulation- Ageing in air oven : Elongation Variation ) |
- |
2500 |
|
- |
19.1 iii) c)(Degree of cross linking ) |
- |
0 |
|
- |
19.1 iii) d)(Phyaical tests for insulation : Hot set ) |
- |
4000 |
|
- |
19.1 iii) d)(Phyaical tests for insulation : Permanent set ) |
- |
0 |
|
- |
19.1 iii) e)(Phyaical tests for insulation : Shrinkage ) |
- |
2500 |
|
- |
19.1 iii) e)(Phyaical tests for insulation : Shrinkage - Crack observed ) |
- |
0 |
|
- |
19.1 iii) f)(Insulation: Waterabsorption(gravimetric)) |
- |
5500 |
|
- |
19.1 v) a)(Test for strippability of semiconducting strippable insulation screen
(when applicable)) |
- |
1000 |
|
- |
19.1 v) b)(Volume resistivity) |
- |
4500 |
|
- |
19.1 vi) a)(Physical tests for outer sheath : Tensile stregth ) |
- |
1500 |
|
- |
19.1 vi) a)(Physical tests for outer sheath : Elongation ) |
- |
1000 |
|
- |
19.1 vi) b)(Physical tests for outer sheath- Ageing in air oven : Tensile stregth ) |
- |
2500 |
|
- |
19.1 vi) b)(Physical tests for outer sheath -Ageing in air oven : Elongation ) |
- |
2500 |
|
- |
19.1 vi) b)(Physical tests for outer sheath- Ageing in air oven : Tensile stregth Variation ) |
- |
0 |
|
- |
19.1 vi) b)(Physical tests for outer sheath -Ageing in air oven : Elongation Variation ) |
- |
0 |
|
- |
19.1 vi) c)(Phyaical tests for Sheath : Shrinkage ) |
- |
1000 |
|
- |
19.1 vi) c)(Phyaical tests for Sheath : Shrinkage - Crack observed ) |
- |
0 |
|
- |
19.1 vi) d)(Sheath : Hot deformation) |
- |
2000 |
|
- |
19.1 vi) e)(Loss of massIn air oven) |
- |
2000 |
|
- |
19.1 vi) f)(Sheath : Heat shock test) |
- |
2000 |
|
- |
19.1 vi) g)(Sheath : Thermalstability) |
- |
1000 |
|
- |
19.1 vi) h)(Carbon black content of polythene
sheath ) |
- |
3500 |
|
Additional charges, If Applicable |
19.1 vii)(Thermal ageing test for complete cable - Tensile stregth ) |
- |
2500 |
|
- |
19.1 vii)(Thermal ageing test for complete cable- Elogation ) |
- |
2500 |
|
- |
19.1 vii)(Thermal ageing test for complete cable- Resistivity ) |
- |
2500 |
|
- |
19.1 xi)(Insulation resistance test : volume resistivity ) |
- |
3500 |
|
- |
20.2(Partial discharge test) |
- |
20000 |
|
- |
20.3(Bending test) |
- |
5000 |
|
- |
20.4(Dielectric power factor test : As a function of voltage) |
- |
7000 |
|
- |
20.4(Dielectric power factor test : As a function of temperature) |
- |
5000 |
|
- |
20.5(Heating Cycle Test) |
- |
25000 |
|
- |
20.6(Impulse withstand test
(Rated voltage, kV 3.8/6.6
Impulse voltage, kV 60)) |
- |
20000 |
|
Additional charges, If Applicable |
20.7(High voltage test) |
- |
10000 |
|
- |
20.8(Flammability test) |
- |
3500 |
|
- |
20.1(Oxygen Index Test) |
- |
2500 |
|
Additional Charge, if applicable |
20.11(Flame Retardance Test on Single Cables) |
- |
2500 |
|
- |
20.12(Flame Retardance Test on Bunched Cables) |
- |
10000 |
|
Additional Charge, if applicable |
20.13(Test for Halogen Acid Gas Evolution) |
- |
4000 |
|
Additional Charge, if applicable |
20.14( Test for Smoke Density) |
- |
4500 |
|
Additional Charge, if applicable |
20.15(Temperature Index) |
- |
0 |
|
Additional Charge, if applicable |
21.1(IDENTIFICATION : Manufacturer's Identification) |
- |
0 |
|
- |
21.2(IDENTIFICATION : Cable Identification) |
- |
0 |
|
- |
21.3(IDENTIFICATION : Cable Code) |
- |
0 |
|
- |
20.3 (a)(Partial discharge test (Bending test)) |
- |
0 |
|
- |
20.5 (a)(PD test (heating cycle test)) |
- |
0 |
|
- |
20.6(Impulse Withstand Test
(Rated voltage, kV 6.35/11
Impulse voltage, kV 75)) |
- |
20000 |
|
as applicable. |
20.6(Impulse Withstand Test
(Rated voltage, kV 11/11
Impulse voltage, kV 95)) |
- |
20000 |
|
as applicable. |
20.6(Impulse Withstand Test
(Rated voltage, kV 12.7/22
Impulse voltage, kV 125)) |
- |
20000 |
|
as applicable. |
20.6(Impulse Withstand Test
(Rated voltage, kV 19/33
Impulse voltage, kV 170)) |
- |
20000 |
|
as applicable. |