IS 9968 : Part 2 (2002) |
Specification for elastomer - Insulated cables: Part 2 for working voltages from 3.3 kV up to and including 33 kV (First Revision) |
- |
-
|
210000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
4.1(CONDUCTORS: Cables for Fixed Installation) |
- |
0 |
|
- |
4.2(CONDUCTORS:Flexible Cables) |
- |
0 |
|
- |
5(INSULATION) |
- |
0 |
|
- |
6(SEMICONDUCTING COMPOUND) |
- |
0 |
|
- |
7.1(Proofed Tape) |
- |
0 |
|
- |
7.1(Proofed Tape: Thickness) |
- |
1000 |
|
- |
7.2(Polyethylene Terephthalate ( P E T P ) or
Polypropylene Base Tape : Thickness) |
- |
1000 |
|
- |
7.3(Tape ) |
- |
0 |
|
- |
8(SCREENING) |
- |
0 |
|
- |
9(CENTRE AND FILLERS) |
- |
0 |
|
- |
10(ARMOUR) |
- |
0 |
|
- |
11.1(Inner Sheath) |
- |
0 |
|
- |
11.2(Outer Sheath) |
- |
0 |
|
- |
12.1(Tapes) |
- |
0 |
|
- |
12.2(Cords and Yarns) |
- |
0 |
|
- |
13.1 & 13.2(CONSTRUCTION:CONDUCTORS-Cables for Fixed Installations/Flexible Cables) |
- |
0 |
|
- |
13.3(Earthing Conductor) |
- |
0 |
|
- |
13.3.1(Earthing Conductor) |
- |
0 |
|
- |
13.4(Separator Tape) |
- |
0 |
|
- |
14(CONDUCTOR SCREENING) |
- |
0 |
|
- |
15.1(INSULATION : Application) |
- |
30000 |
|
Additional Charge, Rs 30,000/- for each additional core. |
15.2(Thickness of Insulation) |
- |
1000 |
|
- |
15.3(Tolerance on Thickness of Insulation) |
- |
0 |
|
- |
16.1(INSULATION SCREENING : Application) |
- |
0 |
|
- |
16.2(INSULATION SCREENING : Parts ) |
- |
0 |
|
- |
16.3(INSULATION SCREENING : Non Metallic Parts ) |
- |
0 |
|
- |
16.4(INSULATION SCREENING : Metallic Parts ) |
- |
0 |
|
- |
17(CORE IDENTIFICATION) |
- |
0 |
|
- |
17(CORE IDENTIFICATION: Unscreed cable ) |
- |
0 |
|
- |
18.1(LAYING UP OF CORES) |
- |
0 |
|
- |
18.2(LAYING UP OF CORES : Flexible cable) |
- |
0 |
|
- |
18.3(LAYING UP OF CORES : Binder Tape) |
- |
0 |
|
- |
19.1(Inner Sheath : Application) |
- |
0 |
|
- |
19.2(Thickness of Inner Sheath) |
- |
1000 |
|
- |
19.3(Inner Sheath : proofed tape) |
- |
0 |
|
- |
20.1(ARMOURING: Application) |
- |
0 |
|
- |
20.2(Type of Armour) |
- |
0 |
|
- |
20.2 1.2(Direction of lay of armour) |
- |
0 |
|
- |
20.2 1.3(Joint in armour) |
- |
0 |
|
- |
20.2.2(Filling Factot ) |
- |
0 |
|
- |
20.2.2(Diameter of braiding) |
- |
1000 |
|
- |
20.2.2.1(Braiding material) |
- |
0 |
|
- |
20.3(Substitution of the galvanized steel wires/formed) |
- |
0 |
|
- |
21.1(OUTER SHEATH) |
- |
0 |
|
- |
21.2(Coulor of Outer sheath) |
- |
0 |
|
- |
21.3(Thickness of Outer Sheat: Average) |
- |
1000 |
|
- |
21.3(Thickness of Outer Sheat: Minimum) |
- |
0 |
|
- |
22.1 a)1)(Annealing test
(for copper) - IS 10810: Part 1) |
- |
1500 |
|
as applicable |
22.1 a)2)(Tensile test
(for aluminium) -IS 10810: Part 2) |
- |
1500 |
|
as applicable |
22.1 a)3)(Wrapping Test
(for aluminium) - IS 10810: Part 3) |
- |
1000 |
|
- |
22.1 a)4)(Conductor resistance
test) |
- |
2500 |
|
- |
22.1 a)5)(Persulphate test
(tinned copper
conductor)- IS 10810: Part 4) |
- |
1500 |
|
as applicable |
22.1 b)1)(Test for Galvanized Steel
Wires/Formed Wires
1) Dimensions -IS 10810: Part 36) |
- |
1000 |
|
- |
22.1 b)2)i)(Test for Galvanized Steel
Wires/Formed Wires
2) Tensile Strentgh -IS 10810: Part 37) |
- |
1000 |
|
- |
22.1 b)2)ii)(Test for Galvanized Steel
Wires/Formed Wires
2) Elongation at break -IS 10810: Part 37) |
- |
1000 |
|
- |
22.1 b)2)iii)(Test for Galvanized Steel
Wires/Formed Wires
3) Torsion (for round
wires only) -IS 10810: Part 38) |
- |
1000 |
|
- |
22.1 b)2)iv)(Test for Galvanized Steel
Wires/Formed Wires
4) Winding (for strips
only) -IS 10810: Part 39) |
- |
1000 |
|
- |
22.1 b)2)v)(Test for Galvanized Steel
Wires/Formed Wires
5) Zinc coating : Uniformity-IS 10810: Part 40) |
- |
2500 |
|
- |
22.1 b)2)vi)(Test for Galvanized Steel
Wires/Formed Wires
5) Zinc coating : Mass -IS 10810: Part 41) |
- |
2500 |
|
- |
22.1 b)2) vii) (Resistivity - IS 10810: Part 42) |
- |
1500 |
|
- |
22.1 c)2)(Physical Tests for
Insulation : Tensile Strenth - IS 10810: Part 7) |
- |
1500 |
|
- |
22.1 c)2)(Physical Tests for
Insulation : Elongation - IS 10810: Part 7) |
- |
1500 |
|
- |
22.1 c)2)(Physical Tests for
Sheath : Tensile Strenth - IS 10810: Part 7) |
- |
1500 |
|
- |
22.1 c)2)(Physical Tests for
Sheath : Elongation - IS 10810: Part 7) |
- |
1500 |
|
- |
22.1 c)3)(Physical Tests for
Insulation ( Ageing in air oven): Tensile Strenth - IS 10810: Part 11) |
- |
2500 |
|
- |
22.1 c)3)(Physical Tests for
Insulation ( Ageing in air oven): Tensile Strenth Variation - IS 10810: Part 12) |
- |
0 |
|
- |
22.1 c)3)(Physical Tests for
Insulation( Ageing in air oven) : Elongation - IS 10810: Part 11) |
- |
2500 |
|
- |
22.1 c)3)(Physical Tests for
Insulation( Ageing in air oven) : Elongation variation - IS 10810: Part 12) |
- |
0 |
|
- |
22.1 c)3)(Physical Tests for
Sheath( Ageing in air oven) : Tensile Strenth - IS 10810: Part 11) |
- |
2500 |
|
- |
22.1 c)3)(Physical Tests for
Sheath( Ageing in air oven) : Tensile Strenth variation - IS 10810: Part 12) |
- |
0 |
|
- |
22.1 c)3)(Physical Tests for
Sheath ( Ageing in air oven): Elongation - IS 10810: Part 11) |
- |
2500 |
|
- |
22.1 c)3)(Physical Tests for
Sheath ( Ageing in air oven): Elongation variation - IS 10810: Part 12) |
- |
0 |
|
- |
22.1 c)4)(Physical Tests for
Insulation ( Ageing in air bomb): Tensile Strenth variation - IS 10810: Part 56) |
- |
2500 |
|
- |
22.1 c)4)(Physical Tests for
Insulation( Ageing in air bomb) : Elongation variation - IS 10810: Part 56) |
- |
2500 |
|
- |
22.1 c)4)(Physical Tests for
Sheath(Ageing in air bomb) : Tensile Strenth variation - IS 10810: Part 56) |
- |
2500 |
|
- |
22.1 c)4)(Physical Tests for
Sheath ( Ageing in air bomb): Elongation variation - IS 10810: Part 56) |
- |
2500 |
|
- |
22.1 c)5)(Physical Tests for
Insulation :Hot set Elongation - IS 10810: Part 30) |
- |
4000 |
|
- |
22.1 c)5)(Physical Tests for
Insulation :Permanent set - IS 10810: Part 30) |
- |
0 |
|
- |
22.1 c)5)(Physical Tests for
Sheath :Hot set Elongation - IS 10810: Part 30) |
- |
5000 |
|
- |
22.1 c)5)(Physical Tests for
Sheath :Permanent set - IS 10810: Part 30) |
- |
0 |
|
- |
22.1 c)6)(Physical Tests for
Sheath(Oil resistance test) : Tensile Strenth Variation - IS 10810: Part 31) |
- |
3000 |
|
- |
22.1 c)6)(Physical Tests for
Sheath ( Oil resistance test): Elongation Variation - IS 10810: Part 31) |
- |
3000 |
|
- |
22.1 c)7)(Tear Resistance test - IS 10810: Part 17) |
- |
5500 |
|
- |
22.1 c)8)(Shrinkage : Insulation - IS 10810: Part 12) |
- |
3500 |
|
- |
22.1 c)8)(Shrinkage test- Crack observed : Insulation - IS 10810: Part 13) |
- |
0 |
|
- |
22.1 c)8)(Shrinkage test : Sheath - IS 10810: Part 12) |
- |
3000 |
|
- |
22.1 c)8)(Shrinkage test - Crack oberved : Sheath - IS 10810: Part 13) |
- |
0 |
|
- |
22.1 c)9)(Hot deformation test : Insulation - IS 10810: Part 15) |
- |
2500 |
|
- |
22.1 c)9)(Hot deformation test : Sheath - IS 10810: Part 15) |
- |
2500 |
|
- |
22.1 c)10)(Loss of mass in air
oven : Insulation - IS 10810: Part 10) |
- |
3000 |
|
- |
22.1 c)10)(Loss of mass in air
oven : Sheath - IS 10810: Part 10) |
- |
3500 |
|
- |
22.1 c)11)(Heat shock : Insulation - IS 10810: Part 14) |
- |
2500 |
|
- |
22.1 c)11)(Heat shock : Sheath - IS 10810: Part 14) |
- |
2500 |
|
- |
22.1 c)12)(Thermal stability : Insulation - IS 10810: Part 60) |
- |
1000 |
|
- |
22.1 c)12)(Thermal stability : Sheath - IS 10810: Part 60) |
- |
1000 |
|
- |
22.1 d)(Insulation Resistance Test: Volume resistivity ) |
- |
3500 |
|
- |
22.1 d)(Insulation Resistance Test: Insulation resistance constant ) |
- |
0 |
|
- |
22.1 e)(Partial Discharge Test) |
- |
18000 |
|
- |
22.1 f)(Bending Test Followed by
Partial Discharge Test) |
- |
0 |
|
- |
22.1 g)(Dielectric Power Factor
Test
1) As a function of Voltage) |
- |
8000 |
|
- |
22.1 g)(Dielectric Power Factor
Test
1) As a function of
temperature) |
- |
7000 |
|
- |
22.1 h)(Heating Cycle Test) |
- |
18000 |
|
- |
22.1 j)(Impulse Withstand Test) |
- |
15000 |
|
- |
22.1 m)(Water Absorption Test - IS 10810: Part 28) |
- |
5500 |
|
- |
22.1 n)(Flammability) |
- |
3000 |
|
- |
24.1(Manufacturer's Identification) |
- |
0 |
|
- |
24.2(Voltage Identification) |
- |
0 |
|
- |
24.3(Cable Code) |
- |
0 |
|
- |
25.2.1(Marking on drum ) |
- |
0 |
|
- |
25.2.2(BIS Certification Marking) |
- |
0 |
|
- |
22.1 k)(High Voltage Test
for Four Hours) |
- |
5000 |
|
- |
|
Complete
|
|
- |
- |
32 |
IS 7098 : Part 3 (1993) |
Cross - Linked polyethylene insulated thermoplastic sheathed cables - Specification: Part 3 for working voltages from 66 kV up to and including 220 kV |
- |
-
|
450000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
4.1(CONDUCTOR) |
- |
0 |
|
- |
5(INSULATION) |
- |
0 |
|
- |
6(SCREENING) |
- |
0 |
|
- |
7.1(MOISTURE BARRIER : Laminated Tape) |
- |
0 |
|
- |
7.2(MOISTURE BARRIER : Lead Alloy Sheath) |
- |
0 |
|
- |
7.3(MOISTURE BARRIER : Water Blocking Tape/Powder) |
- |
0 |
|
- |
8.1(INNER SHEATH) |
- |
0 |
|
- |
8.2(INNER SHEATH) |
- |
0 |
|
- |
8.3(INNER SHEATH) |
- |
0 |
|
- |
9.1(ARMOUR) |
- |
0 |
|
- |
9.2(ARMOUR) |
- |
0 |
|
- |
10.1(OUTER SHEATH) |
- |
0 |
|
- |
10.2(OUTER SHEATH) |
- |
0 |
|
- |
11.1(CONDUCTOR) |
- |
0 |
|
- |
11.2(CONDUCTOR) |
- |
0 |
|
- |
12.1(CONDUCTOR SCREENING ) |
- |
0 |
|
- |
12.2(CONDUCTOR SCREENING ) |
- |
0 |
|
- |
13.1(INSULATION) |
- |
0 |
|
- |
13.2(INSULATION) |
- |
0 |
|
- |
14.1(INSULATION SCREENING) |
- |
0 |
|
- |
14.2.1(INSULATION SCREENING : Non-metallic Part) |
- |
0 |
|
- |
14.2.2(INSULATION SCREENING : Non-metallic Part) |
- |
0 |
|
- |
14.2.3(INSULATION SCREENING : Non-metallic Part) |
- |
0 |
|
- |
14.3.1(INSULATION SCREENING : Metallic Part) |
- |
0 |
|
- |
14.3.2(INSULATION SCREENING : Metallic Part) |
- |
0 |
|
- |
14.3.3(INSULATION SCREENING : Metallic Part) |
- |
0 |
|
- |
15.1(MOISTURE BARRIER) |
- |
0 |
|
- |
15.2.1(Metallic Sheath) |
- |
0 |
|
- |
15.2.2(Metallic Sheath) |
- |
0 |
|
- |
16.1(INNER SHEATH) |
- |
0 |
|
- |
16.2(INNER SHEATH) |
- |
0 |
|
- |
17.1(ARMOUR) |
- |
0 |
|
- |
17.2(ARMOUR) |
- |
0 |
|
- |
17.3(ARMOUR) |
- |
0 |
|
- |
17.4(ARMOUR) |
- |
0 |
|
- |
17.5(ARMOUR) |
- |
0 |
|
- |
18.1(OUTER SHEATH) |
- |
0 |
|
- |
18.2(outer sheath colour) |
- |
0 |
|
- |
18.3.1(Thickness of Outer Sheath : Unarmoured Cables) |
- |
2500 |
|
- |
18.3.1(Thickness of Outer Sheath : armoured Cables) |
- |
2500 |
|
- |
19.1 A) I)(Tests on conductor : Annealing test ( for copper )) |
- |
2500 |
|
- |
19.1 A) II)(Tests on conductor : Resistance test) |
- |
12500 |
|
- |
19.1 b) I)(Test for thickness and dimensions of insulation) |
- |
5000 |
|
- |
19.1 b) II)(Tensile strength and elongation at break) |
- |
5000 |
|
- |
19.1 b) III)(Thermal ageing in air oven) |
- |
10000 |
|
- |
19.1 b) IV)(Hot set test) |
- |
6500 |
|
- |
19.1 b) V)(Shrinkage test) |
- |
3500 |
|
- |
20.3(Test for concentric metallic screen : Test for concentric copper wire) |
- |
5000 |
|
- |
20.4(Test for concentric copper tape) |
- |
5000 |
|
- |
20.5(Thickness of metallic sheath) |
- |
3500 |
|
- |
20.6(Tests for armouring material : Dimensions) |
- |
3500 |
|
- |
19.1 f) II)(Tests for armouring material : Tensile strength and elongation at break) |
- |
2000 |
|
- |
Table 9, (Measurement of thickness) |
- |
1000 |
|
- |
19.1 g)2) i)(PVC sheath : Tensile strength and elongation at break) |
- |
2000 |
|
- |
19.1 g)2) iii)(PVC sheath : Loss of mass) |
- |
5500 |
|
- |
19.1 g)2) v)(PVC sheath : Hot deformation test) |
- |
2500 |
|
- |
19.1 g)2) vi)(PVC sheath : Shrinkage test) |
- |
3500 |
|
- |
19.1 g)2) vii)(PVC sheath : Thermal stability) |
- |
1500 |
|
- |
19.1 g)3) ii)(PE sheath : Tensile strength and elongation at break before and after ageing) |
- |
2000 |
|
If Applicable |
19.1 g)3) iii)(PE sheath : Hot-detormation) |
- |
2500 |
|
Additional Charge, If Applicable |
20.7(Flammabihty test ( for PVC outer
sheathed cables only )) |
- |
3000 |
|
- |
20.8.3(Water tightness test) |
- |
35000 |
|
- |
20.9.1(Thermal ageing on complete cable sample) |
- |
12500 |
|
- |
19.1 k) ii)(Tensile strength and elongation at breakfor insulation and outer sheath) |
- |
0 |
|
- |
20.2(Resistivity test for semi-conducting layer) |
- |
7500 |
|
- |
20.11.1(Bending test followed by P D test) |
- |
65000 |
|
- |
20.12, 20.18(Dielectric power factor and capacitance measurement at ambient temperature) |
- |
18500 |
|
- |
20.13(Dielectric power factor measurement at elevated temperature) |
- |
18500 |
|
- |
20.14.1(Load cycle test followed by P.D measurement) |
- |
75000 |
|
- |
20.15(Impulse Voltage Test Followed by High Voltage Test) |
- |
65000 |
|
- |
19.5(Check on Insulation Thickness Before the Electrical Type Tests) |
- |
4000 |
|
- |
20.16.1(Test for Dimensions of Insulation : Insulation Thickness) |
- |
4000 |
|
- |
20.16.2(Test for Dimensions of Insulation : Test for Eccentricity) |
- |
4000 |
|
- |
20.16.3(Test for Dimensions of Insulation : Test for Ovality) |
- |
3000 |
|
- |
20.17(High Voltage Test ( as Routine and
Acceptance Tests ) ) |
- |
25000 |
|
- |
20.18(Measurement of Capacitance) |
- |
25000 |
|
- |
|
Complete
|
|
- |
Exclusion: Above 66 kv for the following clauses, Testing Facility for Cl.20.17 (High Voltage Test ( as Routine and Acceptance Tests ) ), Cl. 20.18 (Measurement of Capacitance), Cl. 20.15 (Impulse Voltage Test Followed by High Voltage Test), Cl. 20.14.1 (Load cycle test followed by P.D measurement), Cl. 20.13 (Dielectric power factor measurement at elevated temperature), Cl. 20.12, 20.18 (Dielectric power factor and capacitance measurement at ambient temperature), Cl. 20.11.1 (Bending test followed by P D test) |
33 |
IS 14494 (2019) |
Elastomer insulated flexible cables for use in mines - Specification (First Revision) |
- |
-
|
240000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
4(CONDUCTOR) |
- |
0 |
|
Complete Testing Charges : Rs 55000/- Three Core Cable upto 1.1 KV Cable.
Rs 73000/- Three Core Cable for 1.9/3.3 KV Cable.
Rs 80000/- Three Core Cable for 3.8/6.6 KV Cable.
Rs 250000/- Four Core Cable for 6.35/11 KV Cable. |
5(INSULATION) |
- |
0 |
|
- |
5.1(Power Cores) |
- |
0 |
|
- |
5.2(Pilot and Earth Cores) |
- |
0 |
|
- |
6(SEMI-CONDUCTING COMPOUND) |
- |
0 |
|
- |
7.1(TAPE : Proofed Tape) |
- |
0 |
|
- |
7.2(TAPE : Polyethylene Terephalate (PETP) or
Polypropylene Base Tape) |
- |
0 |
|
- |
7.3(TAPE ) |
- |
0 |
|
- |
8(CENTRE) |
- |
0 |
|
- |
9.1(FILLERS) |
- |
0 |
|
- |
9.2(FILLERS) |
- |
0 |
|
- |
10(CRADLE SEPARATOR) |
- |
0 |
|
- |
11.1(ARMOUR) |
- |
0 |
|
- |
11.2(ARMOUR) |
- |
0 |
|
- |
11.2 a)(ARMOURING: Tensile Strength) |
- |
500 |
|
- |
11.2 b)(ARMOURING: Elongation ) |
- |
500 |
|
- |
11.2 c)(ARMOURING: Torsion Test (For round wire ) ) |
- |
500 |
|
- |
11.2 d)(ARMOURING: Uniformity of zinc coating) |
- |
500 |
|
- |
11.2 e)(ARMOURING: Mass of zinc coating ) |
- |
500 |
|
- |
12.1(SHEATH : Inner Sheath) |
- |
0 |
|
- |
12.2(SHEATH : Outer Sheath) |
- |
0 |
|
- |
13.1(REINFORCEMENT MATERIAL : Tape) |
- |
0 |
|
- |
13.2(REINFORCEMENT MATERIAL : Cord/Yarns) |
- |
0 |
|
- |
14.1(CONSTRUCTION : CONDUCTOR) |
- |
0 |
|
- |
14.2(CONSTRUCTION : CONDUCTOR) |
- |
0 |
|
- |
14.3(CONSTRUCTION : CONDUCTOR) |
- |
0 |
|
- |
14.4(CONSTRUCTION : CONDUCTOR) |
- |
0 |
|
- |
15(CONDUCTOR SCREENING) |
- |
0 |
|
- |
16.1(INSULATION) |
- |
1000 |
|
Additional charge, Rs 1000/- for each additional core above three core cable up to 1.9/3.3 kV.
Rs 5000/- for each additional core above three core cable above 1.9/3.3 kV |
16.2(INSULATION : Thickness of Insulation) |
- |
1000 |
|
- |
16.3(INSULATION : Tolerance on Insulation Thickness) |
- |
0 |
|
- |
16.4(INSULATION : Application of Insulation) |
- |
0 |
|
- |
16.5(INSULATION) |
- |
0 |
|
- |
17.1(INSULATION SCREEN) |
- |
0 |
|
- |
17.2(INSULATION SCREEN) |
- |
0 |
|
- |
17.3(INSULATION SCREEN) |
- |
0 |
|
- |
17.4(INSULATION SCREEN) |
- |
0 |
|
- |
18(PROTECTIVE SCREEN) |
- |
0 |
|
- |
19(CONDUCTANCE OF SCREEN) |
- |
0 |
|
- |
19.1(Individual Core Screen) |
- |
0 |
|
- |
19.2(Collective Screen) |
- |
0 |
|
- |
20.1(CORE IDENTIFICATION) |
- |
0 |
|
- |
20.2(Colour Scheme for Identification) |
- |
0 |
|
- |
20.3(Scheme for Identification by Numbering) |
- |
0 |
|
- |
21.1(LAYING UP OF CORES) |
- |
0 |
|
- |
21.2(LAYING UP OF CORES) |
- |
0 |
|
- |
21.3(LAYING UP OF CORES) |
- |
0 |
|
- |
21.4(LAYING UP OF CORES) |
- |
0 |
|
- |
22.1(INNER SHEATH) |
- |
0 |
|
- |
22.2(Thickness of Inner Sheath) |
- |
500 |
|
- |
22.3(INNER SHEATH) |
- |
0 |
|
- |
23.1(ARMOURING) |
- |
0 |
|
- |
23.2(ARMOURING) |
- |
0 |
|
- |
23.3(ARMOURING) |
- |
0 |
|
- |
23.4(ARMOURING) |
- |
0 |
|
- |
24.1(OUTER SHEATH) |
- |
0 |
|
- |
24.2(Thickness of Outer Sheath) |
- |
500 |
|
- |
24.3(Tolerance on Thickness of Outer Sheath) |
- |
0 |
|
- |
24.4(OUTER SHEATH) |
- |
0 |
|
- |
25.1(CABLE CONSTRUCTION AND DIMENSIONS) |
- |
0 |
|
- |
27.2(Bending test followed by partial discharge test;) |
- |
35000 |
|
Additional charge, if applicable |
27.4(Dielectric power factor test) |
- |
25000 |
|
Additional charge, if applicable |
27.5(Heating cycle test followed by partial discharge test;) |
- |
45000 |
|
Additional charge, if applicable |
27.6(Impulse voltage test; and) |
- |
35000 |
|
Additional charge, if applicable |
26.3(Special Provisions) |
- |
0 |
|
- |
27.8(Flammability Test) |
- |
3500 |
|
- |
27.9(Water Absorption Test) |
- |
7500 |
|
- |
28(IDENTIFICATION) |
- |
0 |
|
- |
29.1(PACKING AND MARKING) |
- |
0 |
|
- |
29.2(PACKING AND MARKING) |
- |
0 |
|
- |
30(BIS CERTIFICATION MARKING) |
- |
0 |
|
- |
Table 33®, Annex E(Electric tset on semi-conducting screen) |
- |
25000 |
|
Additional charge, if applicable |
Table 33(n), Cl. No. 27.7(High Voltage test for 4 hrs.) |
- |
5500 |
|
- |
Table 33(j), Cl. No. 27.4(Dielectric Power Factor (as a function of Voltage)) |
- |
0 |
|
- |
Table 33(h), Cl. No. 27.2(Partial discharge test) |
- |
0 |
|
- |
Table 33(f)(Insulation resistance) |
- |
3500 |
|
- |
Table 33(e)(Tear resistance on sheath) |
- |
5500 |
|
- |
Table 33(e)(Oil resistance - Elongation on sheath) |
- |
2500 |
|
- |
Table 33(e)(Oil resistance - Tensile strength on sheath) |
- |
2500 |
|
- |
Table 33(e)(Permanent set on Sheath) |
- |
0 |
|
- |
Table 33(e)(Hot set on Sheath) |
- |
2500 |
|
- |
Table 33(e)(Ageing in air bomb - Elongation on Sheath) |
- |
2500 |
|
- |
Table 33(e)(Ageing in air bomb - Tensile strength on Sheath) |
- |
2500 |
|
- |
Table 33(e)(Elongation at break on Sheath) |
- |
2500 |
|
- |
Table 33(e)(Tensile strength on Sheath) |
- |
2500 |
|
- |
Table 33(d)(Ozone resistance on Insulation) |
- |
12500 |
|
Additional charge, if applicable |
Table 33(d)(Permanent set on Insulation) |
- |
0 |
|
- |
Table 33(d)(Hot set on Insulation) |
- |
4000 |
|
- |
Table 33(d)(Ageing in air bomb - Elongation on Insulation) |
- |
4000 |
|
- |
Table 33(d)(Ageing in air bomb - Tensile strength on Insulation) |
- |
4000 |
|
- |
Table 33(d)(Ageing in air oven - Elongation on Insulation) |
- |
2500 |
|
- |
Table 33(d)(Ageing in air oven - Tensile strength on Insulation) |
- |
2500 |
|
- |
Table 33(d)(Elongation at break on Insulation) |
- |
1000 |
|
- |
Table 33(d)(Tensile strength on Insulation) |
- |
1000 |
|
- |
Table 33(b)(Diameter of armour wire) |
- |
500 |
|
- |
Table 4(Copper purity test) |
- |
9000 |
|
Additional charge, if applicable |
Table 33(a)(Conductor resistance test) |
- |
2500 |
|
- |
Table 33(a)(Annealing test) |
- |
1000 |
|
- |
Table 33(c)(Resistivity of steel wire) |
- |
1000 |
|
- |
|
Complete
|
|
- |
- |
34 |
IS 7098 : Part 2 (2011) |
Crosslinked polyethylene insulated thermoplastic sheathed cables - Specification: Part 2 for working voltages from 3.3 kV up to and including 33 kV (Second Revision) |
- |
-
|
190000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
4.1(CONDUCTOR) |
- |
0 |
|
- |
4.1.1(CONDUCTOR) |
- |
0 |
|
- |
5(INSULATION) |
- |
0 |
|
Complete testing Charge :
Rs.1,90,000/- for Single core cable; Rs.2,40,000/- for Three core cable up to 19/33 kV.
and Rs.4,20,000/- for Single core cable; Rs.6,25,000/- for Three core cable for 33/33 kV. |
6(SCREENING) |
- |
0 |
|
- |
6.1.1(SCREENING : - Non-metallic — Semiconducting Compound) |
- |
0 |
|
- |
6.1.2(SCREENING : - Non-magnetic Metallic Tape for Single Core Unscreened and Unarmoured Cables) |
- |
0 |
|
- |
7(FILLERS AND INNER SHEATH) |
- |
0 |
|
- |
8.1(ARMOURING) |
- |
0 |
|
- |
8.2(ARMOURING) |
- |
0 |
|
- |
9(OUTER SHEATH ) |
- |
0 |
|
- |
10.1(CONDUCTOR) |
- |
0 |
|
- |
10.2(CONDUCTOR) |
- |
0 |
|
- |
11(CONDUCTOR SCREENING) |
- |
0 |
|
- |
12.1(INSULATION) |
- |
0 |
|
- |
12.2(INSULATION : Thickness of Insulation) |
- |
2500 |
|
- |
12.3(INSULATION : Tolerance on Thickness of Insulation) |
- |
0 |
|
- |
12.4(Eccentricity and Ovality) |
- |
2500 |
|
- |
12.5(INSULATION : Application of Insulation) |
- |
0 |
|
- |
13.1(INSULATION SCREENING) |
- |
0 |
|
- |
13.2(INSULATION SCREENING) |
- |
0 |
|
- |
13.3(INSULATION SCREENING) |
- |
0 |
|
- |
13.4(INSULATION SCREENING) |
- |
0 |
|
- |
14.1(CORE IDENTIFICATION) |
- |
25000 |
|
Additional Charge, Rs 25000/- for each additional Core |
14.1.1(CORE IDENTIFICATION) |
- |
0 |
|
- |
15.1(LAVING UP OF CORES) |
- |
0 |
|
- |
16.1(INNER SHEATH (COMMON COVERING)) |
- |
0 |
|
- |
16.2(INNER SHEATH (COMMON COVERING)) |
- |
0 |
|
- |
16.2.1(INNER SHEATH (COMMON COVERING)) |
- |
0 |
|
- |
16.3(INNER SHEATH (COMMON COVERING) : Thickness of Inner Sheath) |
- |
500 |
|
- |
16.3.1(INNER SHEATH (COMMON COVERING) : Thickness of Inner Sheath) |
- |
0 |
|
- |
17.1(ARMOURING : Application ) |
- |
0 |
|
- |
17.1.1(ARMOURING ) |
- |
0 |
|
- |
17.1.2(ARMOURING ) |
- |
0 |
|
- |
17.1.3(ARMOURING ) |
- |
0 |
|
- |
17.2(ARMOURING : Type of armour ) |
- |
0 |
|
- |
17.2.1(ARMOURING : Type of armour ) |
- |
0 |
|
- |
17.2(ARMOURING : Coverage ) |
- |
1500 |
|
- |
17.3(ARMOURING : Dimension ) |
- |
1000 |
|
- |
17.4(ARMOURING : Joints) |
- |
0 |
|
- |
16.4(ARMOURING : Resistance) |
- |
3500 |
|
- |
18.1(OUTER SHEATH) |
- |
0 |
|
- |
18.2(OUTER SHEATH: Colour) |
- |
0 |
|
- |
18.3(Thicknes of outer sheath : average ) |
- |
500 |
|
- |
18.3(Thicknes of outer sheath : minimum ) |
- |
0 |
|
- |
19.1 i) a)(Annealing test (for copper)) |
- |
2500 |
|
Charge, as applicable |
19.1 i) b)(Tensile test (for aluminium) - Before stranding ) |
- |
2500 |
|
Charge, as applicable |
19.1 i) b)(Tensile test (for aluminium) - After stranding ) |
- |
0 |
|
- |
19.1 i) c)(Wrapping test ( for aluminium)) |
- |
0 |
|
- |
19.1 i) d)(Resistance test - Main conductor ) |
- |
3500 |
|
- |
19.1 i) d)(Resistance test - Neutral conductor ) |
- |
0 |
|
- |
19.1 iii) a)(Phyaical tests for insulation : Tensile Test) |
- |
1500 |
|
- |
19.1 iii) a)(Phyaical tests for insulation : Elongation ) |
- |
1000 |
|
- |
19.1 iii) b)(Phyaical tests for insulation - Ageing in air Oven : Tensile Variation ) |
- |
2500 |
|
- |
19.1 iii) b)(Phyaical tests for insulation- Ageing in air oven : Elongation Variation ) |
- |
2500 |
|
- |
19.1 iii) c)(Degree of cross linking ) |
- |
0 |
|
- |
19.1 iii) d)(Phyaical tests for insulation : Hot set ) |
- |
4000 |
|
- |
19.1 iii) d)(Phyaical tests for insulation : Permanent set ) |
- |
0 |
|
- |
19.1 iii) e)(Phyaical tests for insulation : Shrinkage ) |
- |
2500 |
|
- |
19.1 iii) e)(Phyaical tests for insulation : Shrinkage - Crack observed ) |
- |
0 |
|
- |
19.1 iii) f)(Insulation: Waterabsorption(gravimetric)) |
- |
5500 |
|
- |
19.1 v) a)(Test for strippability of semiconducting strippable insulation screen
(when applicable)) |
- |
1000 |
|
- |
19.1 v) b)(Volume resistivity) |
- |
4500 |
|
- |
19.1 vi) a)(Physical tests for outer sheath : Tensile stregth ) |
- |
1500 |
|
- |
19.1 vi) a)(Physical tests for outer sheath : Elongation ) |
- |
1000 |
|
- |
19.1 vi) b)(Physical tests for outer sheath- Ageing in air oven : Tensile stregth ) |
- |
2500 |
|
- |
19.1 vi) b)(Physical tests for outer sheath -Ageing in air oven : Elongation ) |
- |
2500 |
|
- |
19.1 vi) b)(Physical tests for outer sheath- Ageing in air oven : Tensile stregth Variation ) |
- |
0 |
|
- |
19.1 vi) b)(Physical tests for outer sheath -Ageing in air oven : Elongation Variation ) |
- |
0 |
|
- |
19.1 vi) c)(Phyaical tests for Sheath : Shrinkage ) |
- |
1000 |
|
- |
19.1 vi) c)(Phyaical tests for Sheath : Shrinkage - Crack observed ) |
- |
0 |
|
- |
19.1 vi) d)(Sheath : Hot deformation) |
- |
2000 |
|
- |
19.1 vi) e)(Loss of massIn air oven) |
- |
2000 |
|
- |
19.1 vi) f)(Sheath : Heat shock test) |
- |
2000 |
|
- |
19.1 vi) g)(Sheath : Thermalstability) |
- |
1000 |
|
- |
19.1 vi) h)(Carbon black content of polythene
sheath ) |
- |
3500 |
|
Additional charges, If Applicable |
19.1 vii)(Thermal ageing test for complete cable - Tensile stregth ) |
- |
2500 |
|
- |
19.1 vii)(Thermal ageing test for complete cable- Elogation ) |
- |
2500 |
|
- |
19.1 vii)(Thermal ageing test for complete cable- Resistivity ) |
- |
2500 |
|
- |
19.1 xi)(Insulation resistance test : volume resistivity ) |
- |
3500 |
|
- |
20.2(Partial discharge test) |
- |
20000 |
|
- |
20.3(Bending test) |
- |
5000 |
|
- |
20.4(Dielectric power factor test : As a function of voltage) |
- |
7000 |
|
- |
20.4(Dielectric power factor test : As a function of temperature) |
- |
5000 |
|
- |
20.5(Heating Cycle Test) |
- |
25000 |
|
- |
20.6(Impulse withstand test
(Rated voltage, kV 3.8/6.6
Impulse voltage, kV 60)) |
- |
20000 |
|
Additional charges, If Applicable |
20.7(High voltage test) |
- |
10000 |
|
- |
20.8(Flammability test) |
- |
3500 |
|
- |
20.1(Oxygen Index Test) |
- |
2500 |
|
Additional Charge, if applicable |
20.11(Flame Retardance Test on Single Cables) |
- |
2500 |
|
- |
20.12(Flame Retardance Test on Bunched Cables) |
- |
10000 |
|
Additional Charge, if applicable |
20.13(Test for Halogen Acid Gas Evolution) |
- |
4000 |
|
Additional Charge, if applicable |
20.14( Test for Smoke Density) |
- |
4500 |
|
Additional Charge, if applicable |
20.15(Temperature Index) |
- |
0 |
|
Additional Charge, if applicable |
21.1(IDENTIFICATION : Manufacturer's Identification) |
- |
0 |
|
- |
21.2(IDENTIFICATION : Cable Identification) |
- |
0 |
|
- |
21.3(IDENTIFICATION : Cable Code) |
- |
0 |
|
- |
20.3 (a)(Partial discharge test (Bending test)) |
- |
0 |
|
- |
20.5 (a)(PD test (heating cycle test)) |
- |
0 |
|
- |
20.6(Impulse Withstand Test
(Rated voltage, kV 6.35/11
Impulse voltage, kV 75)) |
- |
20000 |
|
as applicable. |
20.6(Impulse Withstand Test
(Rated voltage, kV 11/11
Impulse voltage, kV 95)) |
- |
20000 |
|
as applicable. |
20.6(Impulse Withstand Test
(Rated voltage, kV 12.7/22
Impulse voltage, kV 125)) |
- |
20000 |
|
as applicable. |
20.6(Impulse Withstand Test
(Rated voltage, kV 19/33
Impulse voltage, kV 170)) |
- |
20000 |
|
as applicable. |
|
Complete
|
|
- |
- |
35 |
IS 1180 : Part 1 (2014) |
Outdoor Type Oil Immersed Distribution Transformers Upto and Including 2 500 kVA, 33kV - Specification Part 1 Mineral Oil Immersed (Fourth Revision) |
Mineral Oil Immersed Distribution Transformers |
-
|
120000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
21.2 a)(Measurement of winding resistance ) |
- |
6000 |
|
Complete Testing Charges : Rs.76000/- For 0 to 100 kVA, Rs.86100/- For 100 to 250 kVA, Rs.92000- For 250 kVA to 630 kVA, Rs.93100/- For 630 kVA to 1000 kVA, Rs.117900/- For 1000 kVA to 1600 kVA. Rs.120000/- For 1600 kVA to 2500 kVA. |
21.2 b)( Measurement of voltage ratio and check of
phase displacemen) |
- |
5000 |
|
- |
21.2 c)( Measurement of short-circuit impedance
(principal tapping, when applicable) and load
loss at 50 percent and 100 percent load) |
- |
5000 |
|
- |
21.2 d)(Measurement of no-load loss and current) |
- |
3500 |
|
- |
21.2 e)(Measurement of insulation resistance) |
- |
2000 |
|
- |
21.2 f)(Induced over-voltage withstand test) |
- |
4500 |
|
- |
21.2 g)( Separate-source voltage withstand test) |
- |
4000 |
|
- |
21.5.1.2(Pressure test-routine test (For Transformers up to 200 kVA
)) |
- |
4000 |
|
- |
21.5.1.3(Oil leakage test upto 200 KVA) |
- |
3000 |
|
- |
21.3(a )(Lightning impulse test) |
- |
38000 |
|
- |
21.3(b)(Temperature-rise test) |
- |
23000 |
|
- |
21.5.1.1(Pressure test-Type test (For Transformers up to 200 kVA
)) |
- |
6000 |
|
- |
21.4 a)( Determination of sound levels) |
- |
6000 |
|
- |
21.4 c(No load current at 112.5 percent voltage.) |
- |
1000 |
|
- |
21.4 d(Paint adhesion tests) |
- |
1500 |
|
- |
21.4 e(BDV and moisture content of oil in the transformer) |
- |
1500 |
|
- |
6.9(Permissible Flux Density and Over Fluxing ) |
- |
6000 |
|
- |
13.1(Marking (Rating Plates)) |
- |
0 |
|
- |
13.2(Terminal Marking Plate) |
- |
0 |
|
- |
13.3(Marking ) |
- |
0 |
|
- |
13.4(Marking) |
- |
0 |
|
- |
13.4.1(Marking) |
- |
0 |
|
- |
14.1(MOUNTING ARRANGEMENT) |
- |
0 |
|
- |
14.2(MOUNTING ARRANGEMENT) |
- |
0 |
|
- |
14.3(MOUNTING ARRANGEMENT) |
- |
0 |
|
- |
14.4(MOUNTING ARRANGEMENT) |
- |
0 |
|
- |
15.1.1(TRANSFORMER TANK : Construction) |
- |
0 |
|
- |
15.1.2(TRANSFORMER TANK : Construction) |
- |
0 |
|
- |
15.1.3(TRANSFORMER TANK : Construction) |
- |
0 |
|
- |
15.1.4(TRANSFORMER TANK : Construction) |
- |
0 |
|
- |
15.1.5(TRANSFORMER TANK : Construction) |
- |
0 |
|
- |
21.5.3.3(Oil leakage test) |
- |
0 |
|
- |
21.5.2.1(Type test : For Transformers Above 200 kVA and Up to Including 2 500 kVA) |
- |
120000 |
|
- |
21.5.2.2(routine test :For Transformers Above 200 kVA and Up to Including 2 500 kVA) |
- |
37000 |
|
Routine Testing Charges : Rs.19100/- For 0 to 100 kVA, Rs.22200/- For 100 to 250 kVA, Rs.24700/- For 250 kVA to 630 kVA, Rs.25600/- For 630 kVA to 1000 kVA, Rs.33100/- For 1000 kVA to 1600 kVA. Rs.37000/- For 1600 kVA to 2500 kVA. |
21.5.2.3( Oil leakage test (routine test)) |
- |
0 |
|
- |
21.5.3.1(For Single Phase Distribution Transformers Up to Including 25 kVA : pressure test (type test)) |
- |
0 |
|
- |
21.5.3.2(For Single Phase Distribution Transformers Up to Including 25 kVA : pressure test (routine test)) |
- |
0 |
|
- |
21.5.3.3(Oil leakage test (routine test)) |
- |
0 |
|
- |
15.5(Total Dry Film Paint Thickness) |
- |
0 |
|
- |
6.9, 7.9, 8.9(Permissible Flux Density and Over Fluxing) |
- |
0 |
|
- |
11(Minimum clearance in Air) |
- |
0 |
|
- |
16(Conservator for Non-sealed type Transformers) |
- |
0 |
|
- |
20(Fittings) |
- |
0 |
|
- |
6.8 (50%)(Total losses at 50 % load (Watts)) |
- |
0 |
|
- |
7.8 (50%)(Total losses at 50 % load (Watts)) |
- |
0 |
|
- |
8.8 (50%)(Total losses at 50 % load (Watts)) |
- |
0 |
|
- |
6.8 (100%)(Total losses at 100 % load (Watts)) |
- |
0 |
|
- |
7.8 (100%)(Total losses at 100 % load (Watts)) |
- |
0 |
|
- |
8.8 (100%)(Total losses at 100 % load (Watts)) |
- |
0 |
|
- |
9.1a)(CRGO Electrical Steel) |
- |
0 |
|
- |
9.1 b)(Amorphous core material) |
- |
0 |
|
- |
9.1 c)(Copper/Aluminium conductor) |
- |
0 |
|
- |
9.1 d)(Kraft paper) |
- |
0 |
|
- |
9.1 e)(Press Board) |
- |
0 |
|
- |
9.1 f)(Mineral oil) |
- |
0 |
|
- |
10(Terminal Arrangement) |
- |
0 |
|
- |
15.2(Pressure and Vacuum Requirements) |
- |
0 |
|
- |
15.4(Gasket) |
- |
0 |
|
- |
19(Tolerances) |
- |
0 |
|
- |
18(Efficiency and regulation) |
- |
0 |
|
- |
4(Service Conditions) |
- |
0 |
|
- |
5(General ) |
- |
0 |
|
- |
6.1(Rating) |
- |
0 |
|
- |
6.2(Rated frequency) |
- |
0 |
|
- |
6.3(Nominal system voltage) |
- |
0 |
|
- |
6.4(Basic Insulation level ) |
- |
0 |
|
- |
6.5(No-Load Voltage Ratios) |
- |
0 |
|
- |
6.6(Winding connections and phase displacement) |
- |
0 |
|
- |
6.7(Tapping Range and Tapping Method) |
- |
0 |
|
- |
6.8(Losses and impedance values) |
- |
0 |
|
- |
6.1(Limits of Temperature-rise) |
- |
0 |
|
- |
7(Technical Parameters of three phase distribution trasnformers
higher than 200kva) |
- |
0 |
|
- |
8(Technical Parameters of single phase distribution transformers
UP to and including 25 KVA ) |
- |
0 |
|
- |
9(Standard Materials) |
- |
0 |
|
- |
10(Terminal arrangment ) |
- |
0 |
|
- |
11(Minimum Clearnaces air ) |
- |
0 |
|
- |
12(Connectors ) |
- |
0 |
|
- |
13(Marking ) |
- |
0 |
|
- |
14(Mounting arrangement) |
- |
0 |
|
- |
15(Trasnformer Tank ) |
- |
0 |
|
- |
16(Conservator for Non-Sealed type Transformers) |
- |
0 |
|
- |
18(Efficiency and Regulation) |
- |
0 |
|
- |
19(Tolerances) |
- |
0 |
|
- |
21(General ) |
- |
0 |
|
- |
22(Information required with enquiry and order ) |
- |
0 |
|
- |
20(Fittings) |
- |
0 |
|
- |
|
Complete
|
|
- |
Exclusion: Cl.21.4 b (Short-circuit withstand test IS 2026 (Part 5) (above 200 kVA)), Cl. 17 ( ABILITY OF TRANSFORMERS TO WITHSTAND EXTERNAL SHORT CIRCUIT), Cl. 21.3(c) (Short-circuit withstand test) |
36 |
IS 335 (2018) |
New insulating oils - Specification (Fifth Revision) |
New Insulating Oils |
-
|
42700.00 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
6.1(Viscosity) |
- |
3000.00 |
|
- |
6.2(Pour Point) |
- |
1000.00 |
|
- |
5.1(Classification) |
- |
0.0 |
|
- |
5.2(Requirements) |
- |
0.0 |
|
- |
5.3(Miscibility) |
- |
0.0 |
|
- |
6.0(General) |
- |
0.0 |
|
- |
6..3(Water Content) |
- |
1500.00 |
|
- |
6.4(Breakdown Voltage) |
- |
1700.00 |
|
- |
6.5(Dielectric Dissipation Factor (DDF)) |
- |
2000.00 |
|
- |
6.6(Appearance) |
- |
500.00 |
|
- |
6.7(Acidity) |
- |
1000.00 |
|
- |
6.8(Interfacial Tension (IFT)) |
- |
1000.00 |
|
- |
6.9(Sulphur Content) |
- |
2000.00 |
|
- |
6.1(Corrosive Sulphur and Potentially Corrosive Sulphur) |
- |
1000.00 |
|
- |
6.11(Additives) |
- |
5000.00 |
|
- |
6.12(Oxidation Stability) |
- |
0.0 |
|
- |
6.13(Gassing Tendency) |
- |
1500.00 |
|
- |
6.15(Flash Point) |
- |
1000.00 |
|
- |
6.16(Density) |
- |
1000.00 |
|
- |
6.17(Polycyclic Aromatics (PCA)) |
- |
2500.00 |
|
- |
6.18(Polychlorinated Biphenyls (PCB)) |
- |
2500.00 |
|
- |
6.19(2-Furfural (2-FAL) and Related Compounds Content) |
- |
2500.00 |
|
- |
6.2(Particle Content) |
- |
2000.00 |
|
- |
6.21(DBDS Content) |
- |
2000.00 |
|
- |
7.1 (a)(Total acidity) |
- |
1000.00 |
|
- |
7.1 (b)(Sludge) |
- |
1000.00 |
|
- |
7.1 (c)(DDF at 90°C) |
- |
2000.00 |
|
- |
7.1 (d)(Total sulphur content) |
- |
0.0 |
|
- |
4, 5.1.3, 6.1, Table 1(LCSET) |
- |
0.0 |
|
- |
4, 5.1.3, 6.1, Table 1(Maximum Viscosity) |
- |
0.0 |
|
- |
4, 5.1.3, 6.1, Table 1(Maximum Pour Point) |
- |
0.0 |
|
- |
4, 5.2, 6, Table 2(Viscosity at 40°C) |
- |
0.0 |
|
- |
4, 5.2, 6, Table 2(Viscosity at 0°C) |
- |
0.0 |
|
- |
4, 5.2, 6, Table 2(Viscosity at -30°C) |
- |
0.0 |
|
- |
4, 5.2, 6, Table 2(Viscosity at -40°C) |
- |
0.0 |
|
- |
4, 5.2, 6, Table 2(Pour point) |
- |
0.0 |
|
- |
4, 5.2, 6, Table 2(Water content) |
- |
0.0 |
|
- |
4, 5.2, 6, Table 2(Breakdown voltage) |
- |
0.0 |
|
- |
4, 5.2, 6, Table 2(DDF at 90°C) |
- |
0.0 |
|
- |
4, 5.2, 6, Table 2(Particle content) |
- |
0.0 |
|
- |
4, 5.2, 6, Table 2(Appearance) |
- |
0.0 |
|
- |
4, 5.2, 6, Table 2(Acidity) |
- |
0.0 |
|
- |
4, 5.2, 6, Table 2(Interfacial tension) |
- |
0.0 |
|
- |
4, 5.2, 6, Table 2(Total sulphur content) |
- |
0.0 |
|
- |
4, 5.2, 6, Table 2(Corrosive sulphur) |
- |
0.0 |
|
- |
4, 5.2, 6, Table 2(Potentially corrosive sulphur) |
- |
0.0 |
|
- |
4, 5.2, 6, Table 2(DBDS) |
- |
0.0 |
|
- |
4, 5.2, 6, Table 2(Inhibitors according to IS 13631/IEC 60666) |
- |
0.0 |
|
- |
4, 5.2, 6, Table 2(Metal passivator additives according to IS 13631/IEC 60666) |
- |
0.0 |
|
- |
4, 5.2, 6, Table 2(Other additives) |
- |
0.0 |
|
- |
4, 5.2, 6, Table 2(2-Furfural and related compounds content) |
- |
0.0 |
|
- |
4, 5.2, 6, Table 2(Oxidation stability) |
- |
0.0 |
|
- |
4, 5.2, 6, Table 2(ï€ Total acidity) |
- |
0.0 |
|
- |
4, 5.2, 6, Table 2(ï€ Sludge) |
- |
0.0 |
|
- |
4, 5.2, 6, Table 2(DDF at 90°C) |
- |
0.0 |
|
- |
4, 5.2, 6, Table 2(Gassing tendency) |
- |
0.0 |
|
- |
4, 5.2, 6, Table 2(Flash point) |
- |
0.0 |
|
- |
4, 5.2, 6, Table 2(PCA content) |
- |
0.0 |
|
- |
4, 5.2, 6, Table 2(PCB content) |
- |
0.0 |
|
- |
6.22(Stray Gassing of Oil) |
- |
4000.00 |
|
- |
7.3(Gassing Tendency) |
- |
0.0 |
|
- |
4, 5.2, 6, Table 2(Density at 20°C) |
- |
0.0 |
|
- |
|
Complete
|
|
- |
Exclusion: Cl. 6.14 (Electrostatic Charging Tendency (ECT)), Cl. 7.2 (Electrostatic Charging Tendency (ECT)), Cl. 4, 5.2, 6, Table 2 (ECT) |
37 |
IS 191 (2007) |
Copper - Specification (Fourth Revision) |
- |
-
|
9000.00 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
7.1 - Table 4(Antimony-IS440) |
- |
500.00 |
|
- |
7.1 - Table 4(Arsenic- IS440) |
- |
500.00 |
|
- |
7.1 - Table 4(Bismuth-IS 440) |
- |
500.00 |
|
- |
7.1 - Table 4(Copper (any Silver present to be counted as copper)-IS440) |
- |
500.00 |
|
- |
7.1 - Table 4(Iron IS 440) |
- |
500.00 |
|
- |
7.1 - Table 4(Lead IS 440) |
- |
500.00 |
|
- |
7.1 - Table 4(Nickel IS 440) |
- |
500.00 |
|
- |
7.1 - Table 4(Oxygen IS 440) |
- |
500.00 |
|
- |
7.1 - Table 4(Phosphorus- IS 440) |
- |
500.00 |
|
- |
7.1 - Table 4(Silver- IS 440) |
- |
500.00 |
|
- |
7.1 - Table 4(Sulphur- IS 440) |
- |
500.00 |
|
- |
7.1 - Table 4(Tin - IS 440) |
- |
500.00 |
|
- |
7.1 - Table 4(Tellurium- IS 440) |
- |
500.00 |
|
- |
7.1 - Table 4(Selenium - IS 440) |
- |
500.00 |
|
- |
7.1 - Table 4(Znic-IS 440) |
- |
500.00 |
|
- |
4-Table 1(GRADES/DESIGNATIONS) |
- |
0.0 |
|
- |
7.1 - Table 4(Copper + Silver(By difference)-IS440) |
- |
0.0 |
|
- |
5.1- Table 2(L) |
- |
0.0 |
|
- |
5.1- Table 2(L1) |
- |
0.0 |
|
- |
5.1- Table 2(h) |
- |
0.0 |
|
- |
5.1- Table 2(h1) |
- |
0.0 |
|
- |
5.1- Table 2(b) |
- |
0.0 |
|
- |
5.1- Table 2(b1) |
- |
0.0 |
|
- |
5.1- Table 2(R) |
- |
0.0 |
|
- |
5.1- Table 2(R1) |
- |
0.0 |
|
- |
5.1- Table 2(R2 ) |
- |
0.0 |
|
- |
5.1- Table 2(α ) |
- |
0.0 |
|
- |
5.1- Table 2( β ) |
- |
0.0 |
|
- |
5.1- Table 2(γ) |
- |
0.0 |
|
- |
7.1 - Table 4(Selenium + Telluuium- IS 440) |
- |
0.0 |
|
- |
7.1 - Table 4(Total Impurities- IS 440) |
- |
0.0 |
|
- |
5.2(Billets) |
- |
0.0 |
|
- |
5.4-Table 3 (For Billets)(Mass) |
- |
0.0 |
|
- |
5.2-Table 3 (For Billets)(Diameter) |
- |
0.0 |
|
- |
5.2-Table 3 (For Billets)(Length) |
- |
0.0 |
|
- |
5.2-Table 3 (For Billets)(Deviation from straightness per 1000 mm length) |
- |
0.0 |
|
- |
5.4-Table 3 (Vertically continuously cast wire bars)(Mass) |
- |
0.0 |
|
- |
5.3-Table 3 (Vertically continuously cast wire bars)(Width) |
- |
0.0 |
|
- |
5.3-Table 3 (Vertically continuously cast wire bars)(thickness ) |
- |
0.0 |
|
- |
5.3-Table 3 (Vertically continuously cast wire bars)(Other dimention) |
- |
0.0 |
|
- |
5.4-Table 3 (Vertically static cast wire bars)(Mass) |
- |
0.0 |
|
- |
5.3-Table 3 (Vertically static cast wire bars)(Width) |
- |
0.0 |
|
- |
5.3-Table 3 (Vertically static cast wire bars)(thickness ) |
- |
0.0 |
|
- |
5.3-Table 3 (Vertically static cast wire bars)(Other dimention) |
- |
0.0 |
|
- |
5.4-Table 3 (Ingots)(Mass) |
- |
0.0 |
|
- |
5.4-Table 3 (Cast cakes)(Mass) |
- |
0.0 |
|
- |
5.3-Table 3 (Cast cakes)(Width) |
- |
0.0 |
|
- |
5.3-Table 3 (Cast cakes)(thickness ) |
- |
0.0 |
|
- |
5.3-Table 3 (Cast cakes)(Deviation from straightness per 1000 mm length) |
- |
0.0 |
|
- |
8.1(FREEDOM FROM DEFECTS) |
- |
0.0 |
|
- |
8.2(FREEDOM FROM DEFECTS) |
- |
0.0 |
|
- |
9.1- Table 5(Mass Resistivity- IS 3635) |
- |
0.0 |
|
- |
10(HYDROGEN EMBRITTLEMENT TEST- IS 191) |
- |
1000.00 |
|
- |
4-Table 1(GRADES/DESIGNATIONS) |
- |
0.0 |
|
- |
5.1- Table 2(L) |
- |
0.0 |
|
- |
5.1- Table 2(L1) |
- |
0.0 |
|
- |
5.1- Table 2(h) |
- |
0.0 |
|
- |
5.1- Table 2(h1) |
- |
0.0 |
|
- |
5.1- Table 2(b) |
- |
0.0 |
|
- |
5.1- Table 2(b1) |
- |
0.0 |
|
- |
5.1- Table 2(R) |
- |
0.0 |
|
- |
5.1- Table 2(R1) |
- |
0.0 |
|
- |
5.1- Table 2(R2 ) |
- |
0.0 |
|
- |
5.1- Table 2(α ) |
- |
0.0 |
|
- |
5.1- Table 2( β ) |
- |
0.0 |
|
- |
5.1- Table 2(γ) |
- |
0.0 |
|
- |
5.2(Billets) |
- |
0.0 |
|
- |
5.4-Table 3 (For Billets)(Mass) |
- |
0.0 |
|
- |
5.2-Table 3 (For Billets)(Diameter) |
- |
0.0 |
|
- |
5.2-Table 3 (For Billets)(Length) |
- |
0.0 |
|
- |
5.2-Table 3 (For Billets)(Deviation from straightness per 1000 mm length) |
- |
0.0 |
|
- |
5.4-Table 3 (Vertically continuously cast wire bars)(Mass) |
- |
0.0 |
|
- |
5.3-Table 3 (Vertically continuously cast wire bars)(Width) |
- |
0.0 |
|
- |
5.3-Table 3 (Vertically continuously cast wire bars)(thickness ) |
- |
0.0 |
|
- |
5.3-Table 3 (Vertically continuously cast wire bars)(Other dimention) |
- |
0.0 |
|
- |
5.4-Table 3 (Vertically static cast wire bars)(Mass) |
- |
0.0 |
|
- |
5.3-Table 3 (Vertically static cast wire bars)(Width) |
- |
0.0 |
|
- |
5.3-Table 3 (Vertically static cast wire bars)(thickness ) |
- |
0.0 |
|
- |
5.3-Table 3 (Vertically static cast wire bars)(Other dimention) |
- |
0.0 |
|
- |
5.4-Table 3 (Ingots)(Mass) |
- |
0.0 |
|
- |
5.4-Table 3 (Cast cakes)(Mass) |
- |
0.0 |
|
- |
5.3-Table 3 (Cast cakes)(Width) |
- |
0.0 |
|
- |
5.3-Table 3 (Cast cakes)(thickness ) |
- |
0.0 |
|
- |
5.3-Table 3 (Cast cakes)(Deviation from straightness per 1000 mm length) |
- |
0.0 |
|
- |
7.1 - Table 4(Copper + Silver(By difference)-IS440) |
- |
0.0 |
|
- |
7.1 - Table 4(Silver- IS 440) |
- |
0.0 |
|
- |
7.1 - Table 4(Copper (any Silver present to be counted as copper)-IS440) |
- |
0.0 |
|
- |
7.1 - Table 4(Phosphorus- IS 440) |
- |
0.0 |
|
- |
7.1 - Table 4(Arsenic- IS440) |
- |
0.0 |
|
- |
7.1 - Table 4(Antimony-IS440) |
- |
0.0 |
|
- |
7.1 - Table 4(Bismuth-IS 440) |
- |
0.0 |
|
- |
7.1 - Table 4(Iron IS 440) |
- |
0.0 |
|
- |
7.1 - Table 4(Lead IS 440) |
- |
0.0 |
|
- |
7.1 - Table 4(Nickel IS 440) |
- |
0.0 |
|
- |
7.1 - Table 4(Oxygen IS 440) |
- |
0.0 |
|
- |
7.1 - Table 4(Selenium - IS 440) |
- |
0.0 |
|
- |
7.1 - Table 4(Sulphur- IS 440) |
- |
0.0 |
|
- |
7.1 - Table 4(Tellurium- IS 440) |
- |
0.0 |
|
- |
7.1 - Table 4(Tin - IS 440) |
- |
0.0 |
|
- |
7.1 - Table 4(Znic-IS 440) |
- |
0.0 |
|
- |
7.1 - Table 4(Selenium + Telluuium- IS 440) |
- |
0.0 |
|
- |
7.1 - Table 4(Total Impurities- IS 440) |
- |
0.0 |
|
- |
8.1(FREEDOM FROM DEFECTS) |
- |
0.0 |
|
- |
8.2(FREEDOM FROM DEFECTS) |
- |
0.0 |
|
- |
9.1- Table 5(Mass Resistivity- IS 3635) |
- |
0.0 |
|
- |
10(HYDROGEN EMBRITTLEMENT TEST- IS 191) |
- |
0.0 |
|
- |
9.1 , 9.2 & 10(Resistivity & HYDROGEN EMBRITTLEMENT TEST) |
- |
500.00 |
|
- |
9.1 , 9.2 & 10(Resistivity & HYDROGEN EMBRITTLEMENT TEST) |
- |
0.0 |
|
- |
13(Marking) |
- |
0.0 |
|
- |
13(Marking) |
- |
0.0 |
|
- |
13(Marking) |
- |
0.0 |
|
- |
|
Complete
|
|
- |
- |
38 |
IS 17505 : Part 1 (2021) |
Specification for Thermosetting Insulated Fire Survival Cables for Fixed Installation having Low Emission of Smoke and Corrosive Gases when Affected by Fire for Working Voltages upto and including 1100 Vac and 1500 Vdc |
- |
-
|
174000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Cl. 7.3, Table 1 to 5 of IS 8130:2013 & IS:10810 (Part 5)-1984(Conductor Resistance Test) |
- |
1500 |
|
- |
Cl. 7.1.2 of IS 8130 : 2013 & IS:10810 (Part 1)-1984(Annealing Test (for copper)) |
- |
1000 |
|
- |
Cl. 7.1.1 of IS 8130:2013 & IS:10810 (Part 4)-1984(Persulphate Test for tinned copper) |
- |
1000 |
|
Additional charges, If applicable |
IS 191:2007 & IS 440(Copper purity test) |
- |
9000 |
|
Additional charges, If applicable |
Cl. 11,14,16, Table 4 and Table 6 of IS 17505 & IS:10810 (Part 6)-1984(Test for overall dimensions and thickness of insulation and sheath) |
- |
1500 |
|
Additional charge, Rs. 2000 /- For each additional core |
Table 7 of IS 17505-1:2021, IS 3975:1999 & IS:10810 (Part 36)-1984(Diameter of armour Wire) |
- |
1000 |
|
- |
Table 7 of IS 17505-1:2021, IS 3975:1999 & IS:10810 (Part 37)-1984(Tensile strength and elongation at break) |
- |
1500 |
|
- |
Table 7 of IS 17505-1:2021, IS 3975:1999 & IS:10810 (Part 38)-1984(Torsion Test on galvanised steel wire for armouring) |
- |
1000 |
|
- |
Table 7 of IS 17505-1:2021, IS 3975:1999 & IS:10810 (Part 39)-1984(Winding Test for Formed Wires) |
- |
1000 |
|
- |
Table 7 of IS 17505-1:2021, IS 3975:1999 & IS:10810 (Part 40)-1984(Uniformity of Zinc coating on Round Steel Wires and Formed Steel Wires (Strips)) |
- |
1500 |
|
- |
Table 7 of IS 17505-1:2021, IS 3975:1999 & IS:10810 (Part 41)-1984(Mass of Zinc coating on Round Steel Wires and Formed Steel Wires (Strips)) |
- |
2500 |
|
- |
Table 7 of IS 17505-1:2021, IS 3975:1999 & IS:10810 (Part 42)-1984(Resistivity test) |
- |
1500 |
|
- |
Table 1 and Table 2 of IS 17505 -1: 2021, IS:10810 (Part 7)-1984 & IS:10810 (Part 11)-1984(Tensile Strength and elongation at break before and after ageing.) |
- |
1500 |
|
- |
Cl 18.2 of IS 17505-1:2021 & IS:10810 (Part 45)-1984(High voltage test) |
- |
2500 |
|
- |
Table 1 of IS 17505-1 :2021 & IS:10810 (Part 43)-1984(Insulation Resistance) |
- |
1500 |
|
- |
Cl. 18.6 of IS 17505-1:2021 & IS:10810 (Part 58)-1998(Oxygen index) |
- |
2500 |
|
Not applicable for thermoset material |
Cl. 18.7 of IS 17505-1:2021 & IS:10810 (Part 64)-2003(Temperature Index) |
- |
2500 |
|
Not applicable for thermoset material |
Table-1 & Table-2 of IS 17505-1:2021 & IS:10810 (Part 11)-1984(Ageing in air oven.) |
- |
3500 |
|
- |
Specification for thermosetting insulated fire survival cables for fixed installation having low emission of smoke and corrosive gases when affected by fire for working voltages upto and including 1100 V A.C. and 1500 V D.C(Hot deformation) |
- |
1500 |
|
- |
Table-1 & Annex-F (F.1, F.2, F.3 F.4) of IS 17505-1 :2021(pH) |
- |
4000 |
|
Additional charges, If applicable (For Insulation) |
Table-1 & Annex-F (F.1, F.2, F.3 F.4) of IS 17505-1 :2021(Conductivity) |
- |
4000 |
|
Additional charges, If applicable (For Insulation) |
Table-1 & Annex-F (F.1, F.2, F.3 F.4) of IS 17505-1 :2021(HCl and HBr) |
- |
6000 |
|
Additional charges, If applicable (For Insulation) |
Table-1 & Annex-F (F.1, F.2, F.3 F.4) of IS 17505-1 :2021(Presence of Fluorine / Fluorine Content (if required)) |
- |
21000 |
|
Additional charges, If applicable (For Insulation) |
Table 1 of IS 17505-1: 2021 & IS:10810 (Part 21)-1984(Cold impact test) |
- |
3000 |
|
- |
Table 1 & 2 of IS 17505-1: 2021 & IS:10810 (Part 30)-1984(Hot set test) |
- |
3000 |
|
- |
Table 1 & 2 of IS 17505-1: 2021 & IS:10810 (Part 13)-1984(Ozone Resistance test) |
- |
12500 |
|
- |
Cl 18.5.1 of IS 17505-1 :2021 & IS:10810 (Part 61)-1988(Flame test on single cable) |
- |
3000 |
|
- |
Table 1 of IS 17505-1:2021 & IS:10810 (Part 12)-1984(Shrinkage test) |
- |
1500 |
|
- |
Cl 7 & Annex-F (F.1, F.2, F.3 F.4) of IS 17505-1 :2021(pH) |
- |
4000 |
|
- |
Cl 7 & Annex-F (F.1, F.2, F.3 F.4) of IS 17505-1 :2021(Conductivity) |
- |
4000 |
|
- |
Cl 7 & Annex-F (F.1, F.2, F.3 F.4) of IS 17505-1 :2021(HCl and HBr) |
- |
6000 |
|
- |
Cl 7 & Annex-F (F.1, F.2, F.3 F.4) of IS 17505-1 :2021(Presence of Fluorine / Fluorine Content (if required)) |
- |
21000 |
|
- |
Tabel 1 and 2 of IS 17505-1:2021 & IS:10810 (Part 7)-1984(Tensile strength and elongation at break.) |
- |
0 |
|
- |
Tabel 1 and 2 of IS 17505-1:2021 & IS:10810 (Part 11)-1984(Ageing in air oven.) |
- |
0 |
|
- |
Cl 18.6 of IS 17505-1: 2021 & IS:10810 (Part 58)-1998(Oxygen Index.) |
- |
2500 |
|
Not applicable for thermoset material |
Cl 18.8 of IS 17505-1:2021 & IS:10810 (Part 64)-2003(Temperature Index) |
- |
2500 |
|
Not applicable for thermoset material |
Table 1 & 2 of IS 17505-1: 2021 & IS:10810 (Part 13)-1984(Ozone resistance test) |
- |
0 |
|
- |
Table 2 of IS 17505-1:2021 & IS:10810 (Part 15)-1984(Hot deformation) |
- |
1500 |
|
- |
Cl 7 & Annex-F (F.1, F.2, F.3 F.4) of IS 17505-1 :2021(pH) |
- |
0 |
|
- |
Cl 7 & Annex-F (F.1, F.2, F.3 F.4) of IS 17505-1 :2021(Conductivity) |
- |
0 |
|
- |
Cl 7 & Annex-F (F.1, F.2, F.3 F.4) of IS 17505-1 :2021(HCl and HBr) |
- |
0 |
|
- |
Cl 7 & Annex-F (F.1, F.2, F.3 F.4) of IS 17505-1 :2021(Presence of Fluorine / Fluorine Content (if required)) |
- |
0 |
|
- |
Table 1 of IS 17505-1:2021 & IS:10810 (Part 12)-1984(Shrinkage test) |
- |
0 |
|
- |
Cl 18.2of IS 17505-1:2021 & IS:10810 (Part 45)-1984.(High Voltage test.) |
- |
0 |
|
- |
Cl 18.5of IS 17505-1:2021 & IS:10810 (Part 53)-1984(Flammability Test) |
- |
2500 |
|
- |
Table-2 of IS 17505-1:2021 & IS:10810 (Part 20)-1984(Cold bend test) |
- |
2000 |
|
- |
Table-2 of IS 17505-1:2021 & IS:10810 (Part 21)-1984(Cold impact test) |
- |
0 |
|
- |
Cl 18.5 of IS 17505-1:2021 & IS:10810 (Part 61)-1988(Flammability Test) |
- |
0 |
|
- |
Cl 18.9 of IS 17505-1:2021(Water immersion test ( effect of water on sheath of cable)) |
- |
5500 |
|
- |
Cl 18.8 of IS 17505-1:2021& IS:10810 (Part 63)-1993(Smoke density test) |
- |
10000 |
|
Smoke density test (3-meter cube) |
Cl. 3.5, 18.4 & Annex-E of IS 17505-1:2021(Circuit integrity test under fire) |
- |
45000 |
|
- |
Cl. 17.1 Table 9 (iv) e(Heat Shock) |
- |
1500 |
|
- |
Cl. 17.1 Table 9 (iv) h(Water absorption (Gravimetric)) |
- |
5500 |
|
- |
Cl. 17.1 Table 9 (vii) b(Flame test on bunched cable) |
- |
8500 |
|
- |
Cl. 17.1 Table 9 (ix)(Abrasion resistance test) |
- |
5500 |
|
- |
|
Complete
|
|
- |
- |