| 1 |
IS 17980 (2022) |
Maximum Power Point Tracking Efficiency of Grid Connected Photovoltaic Inverters (First Revision) |
-- |
250000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl-4.1 (a)(Static MPPT efficiency) |
- |
20000 |
|
N/A |
| Cl-4.1 (b)(Dynamic MPPT efficiency) |
- |
10000 |
|
N/A |
| Cl-4.3.2(Measurement procedure) |
- |
10000 |
|
N/A |
| Cl-4.3.3(Evaluation – Calculation of static MPPT efficiency) |
- |
10000 |
|
N/A |
| Cl-4.4(Test conditions for dynamic MPPT efficiency) |
- |
10000 |
|
N/A |
| Cl-5(Calculation of the overall efficiency) |
- |
10000 |
|
N/A |
| A.1.1 in Annex A(PV generator simulator-General) |
- |
10000 |
|
N/A |
| A.1.2 in Annex A(Requirements on the static characteristic) |
- |
10000 |
|
N/A |
| A.1.3 in Annex A(Requirement on the transient stability) |
- |
10000 |
|
N/A |
| A.1.4 in Annex A(Requirements on the dynamic characteristic) |
- |
10000 |
|
N/A |
| A.1.5 in Annex A(Requirements on electrical characteristic) |
- |
10000 |
|
N/A |
| A.2 in Annex A(AC power supply) |
- |
10000 |
|
N/A |
| B.2 in Annex B(Test sequence with ramps 10 % – 50 % GSTC) |
- |
10000 |
|
N/A |
| B.3 in Annex B(Test sequence with ramps 30 % – 100 % GSTC) |
- |
10000 |
|
N/A |
| B.4 in Annex B(Start-up and shut-down test with slow ramps) |
- |
10000 |
|
N/A |
| C.1 in Annex C(PV generator model for MPPT performance tests) |
- |
10000 |
|
N/A |
| C.2 in Annex C(Alternative PV generator model for MPPT performance tests) |
- |
10000 |
|
N/A |
| D.1 in Annex D(European efficiency) |
- |
10000 |
|
N/A |
| D.2 in Annex D(CEC efficiency) |
- |
10000 |
|
N/A |
| E.1 in Annex E(static MPPT and conversion efficiency- General) |
- |
10000 |
|
N/A |
| E.2 in Annex E(Re-normalisation of output power PAC to the rated output power PAC,r) |
- |
10000.01 |
|
N/A |
| E.3 in Annex E(Representation of the conversion efficiency in terms of normalised rated output power) |
- |
10000 |
|
N/A |
| E.4 in Annex E(Interpolation on normative nodes) |
- |
10000 |
|
N/A |
| Cl-4.3.1(Static MPPT efficiency-Test conditions) |
- |
5000 |
|
N/A |
| Cl-4.2(Test set-up) |
- |
5000 |
|
N/A |
|
02 Sep, 2028 |
- Included w.e.f-28.09.2026 |
| 2 |
IS 16169 (2019) |
Utility - Interconnected photovoltaic inverters - Test procedure of islanding prevention measures (First Revision) |
-- |
150000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6(Test for single or multi-phase inverter) |
- |
50000 |
|
N/A |
| Annex A(Islanding as it applies to PV systems) |
- |
25000 |
|
N/A |
| Annex B(Test for independent islanding device) |
- |
20000 |
|
N/A |
| 6 to 6.2(Test for single or multi-phase inverter to Pass/fail criteria) |
- |
15000 |
|
N/A |
| 7(Documentation) |
- |
10000 |
|
N/A |
| 4(Testing circuit) |
- |
15000 |
|
N/A |
| 5(Testing equipment) |
- |
10000 |
|
N/A |
| Annex C(Gate blocking signal) |
- |
5000 |
|
N/A |
|
02 Sep, 2028 |
- Included w.e.f. 22.07.2026 |
| 3 |
IS 16221 : Part 2 (2015) |
Safety of power converters for use in photovoltaic power systems: Part 2 particular requirements for inverters |
-- |
160000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4(General Test Requireements) |
- |
3000 |
|
N/A |
| 5(Marking and documentation) |
- |
3000 |
|
N/A |
| 7(Protection against electric shock and energy hazards) |
- |
2000 |
|
N/A |
| 8(Protection against Mechanical Hazards) |
- |
3000 |
|
N/A |
| 9(Protection against Fire Hazards) |
- |
2000 |
|
N/A |
| 10(Protection against Sonic Pressure Hazards) |
- |
2000 |
|
N/A |
| 11(Protection against Liquid Hazards) |
- |
3000 |
|
N/A |
| 12(Protection against Chemical Hazards) |
- |
2000 |
|
N/A |
| 13(Physical Requirements) |
- |
3000 |
|
N/A |
| 14(Components) |
- |
5000 |
|
N/A |
| 14(Components) |
- |
0 |
|
N/A |
| 6.4(UV exposure) |
- |
0 |
|
N/A |
| 13.6.4(UV Resistance) |
- |
0 |
|
N/A |
| Annex J(Ultraviolet light conditioning test) |
- |
0 |
|
N/A |
| 9.1.4.3(Hot flaming oil test) |
- |
3000 |
|
N/A |
| Clause No. 4.3(Thermal testing) |
- |
4000 |
|
N/A |
| Clause No. 4.4(Testing in single fault condition) |
- |
3000 |
|
N/A |
| 4.5(Humidity preconditioning) |
- |
5000 |
|
N/A |
| 4.6(Backfeed voltage protection) |
- |
3000 |
|
N/A |
| 4.7(Electrical rating tests) |
- |
4000 |
|
N/A |
| 4.8(Additional tests for grid interactive inverters) |
- |
2000 |
|
N/A |
| 4(General Test Requirements) |
- |
2000 |
|
N/A |
| 5(Marking and documentation) |
- |
3000 |
|
N/A |
| 6(Environmental requirements and conditions) |
- |
2000 |
|
N/A |
| 7(Protection against electric shock and energy hazards) |
- |
3000 |
|
N/A |
| 8(Protection against Mechanical Hazards) |
- |
2000 |
|
N/A |
| 9(Protection against Fire Hazards) |
- |
2000 |
|
N/A |
| 10(Protection against Sonic Pressure Hazards) |
- |
2000 |
|
N/A |
| 11(Protection against Liquid Hazards) |
- |
2000 |
|
N/A |
| 12(Protection against Chemical Hazards) |
- |
2000 |
|
N/A |
| 13(Physical Requirements) |
- |
3000 |
|
N/A |
| 4.4.4.15.1(Fault-tolerance of residual current monitoring) |
- |
3000 |
|
N/A |
| 4.4.4.15.2(Fault-tolerance of automatic disconnecting means) |
- |
5000 |
|
N/A |
| 4.4.4.16(Stand-alone inverters – Load transfer test) |
- |
4000 |
|
N/A |
| 4.4.4.17(Cooling system failure – Blanketing test) |
- |
3000 |
|
N/A |
| 4.7.3(Measurement requirements for AC output ports for stand-alone inverters) |
- |
3000 |
|
N/A |
| 4.7.4(Stand-alone Inverter AC output voltage and frequency) |
- |
2000 |
|
N/A |
| 4.7.4.2(Steady state output voltage at nominal DC input) |
- |
3000 |
|
N/A |
| 4.7.4.3(Steady state output voltage across the DC input range) |
- |
5000 |
|
N/A |
| 4.7.4.4(Load step response of the output voltage at nominal DC input) |
- |
5000 |
|
N/A |
| 4.7.4.5(Steady state output frequency) |
- |
3000 |
|
N/A |
| 4.7.5(Stand-alone inverter output voltage waveform) |
- |
3000 |
|
N/A |
| 4.7.5.2(Sinusoidal output voltage waveform requirements) |
- |
3000 |
|
N/A |
| 4.7.5.3(Non-sinusoidal output waveform requirements) |
- |
3000 |
|
N/A |
| 4.7.5.5(Output voltage waveform requirements for inverters for dedicated loads) |
- |
4000 |
|
N/A |
| 4.8.2.1(Array insulation resistance detection for inverters for ungrounded arrays) |
- |
4000 |
|
N/A |
| 4.8.2.2(Array insulation resistance detection for inverters for functionally grounded arrays) |
- |
3000 |
|
N/A |
| 4.8.3.2(30 mA touch current type test for isolated inverters) |
- |
3000 |
|
N/A |
| 4,8.3.3(Fire hazard residual current type test for isolated inverters) |
- |
5000 |
|
N/A |
| 4.8.3.5(Protection by residual current monitoring) |
- |
2000 |
|
N/A |
| 7.3.10(Additional requirements for stand-alone inverters) |
- |
2000 |
|
N/A |
| 9.3.4(Inverter backfeed current onto the array) |
- |
3000 |
|
N/A |
| 13.9(Fault indication) |
- |
2000 |
|
N/A |
| 14(Components) |
- |
0 |
|
N/A |
| Cl.13.6.1.1(Thermal index or capability) |
- |
3000 |
|
N/A |
| Cl.13.6.3.1(Resistance to arcing) |
- |
2000 |
|
N/A |
| Cl.14.8(Batteries) |
- |
3000 |
|
N/A |
| Cl.15(Software and firmware performing safety functions) |
- |
2000 |
|
N/A |
| 6(Environmental requirements and conditions) |
- |
2000 |
|
N/A |
|
02 Sep, 2028 |
- Included w.e.f. 05.06.2026 |
| 4 |
IS 4250 (2025) |
Electric Food-Mixers (Liquidizers and Grinders) and Centrifugal Juicers � Specification ( Second Revision ) |
-- |
40000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl-4(General Requirements) |
- |
1000 |
|
N/A |
| Cl-5(General Conditions for the tests) |
- |
1000 |
|
N/A |
| Cl-6(Classification) |
- |
1000 |
|
N/A |
| Cl-7(Marking) |
- |
2000 |
|
N/A |
| Cl-8(Safety Requirements) |
- |
3000 |
|
N/A |
| Cl-9(Endurance fpr motor and base assembly) |
- |
2000 |
|
N/A |
| Cl-10.2("Grinding Coffee (for Machines that Have a
Dry Grinding Arrangement)") |
- |
3000 |
|
N/A |
| Cl-10.3(Whisking Egg Whites (for Machines that have Whisking Egg Arrangement)) |
- |
2000 |
|
N/A |
| Cl-10.4(Idli Batter) |
- |
1000 |
|
N/A |
| Cl-10.5(Operational Tests for Juicers) |
- |
2000 |
|
N/A |
| Cl-11(Temperature Withstand Test for Bowl) |
- |
3000 |
|
N/A |
| Cl-12.1(Test for Switches) |
- |
2000 |
|
N/A |
| Cl-13(Strength of Assembly) |
- |
2000 |
|
N/A |
| Cl-14.2, 14.3 Table-2 (i)(Protection against access to live parts) |
- |
3000 |
|
N/A |
| Cl-14.2, Table-2 (ii)(Power input and current) |
- |
3000 |
|
N/A |
| Cl-14.2, 14.3 Table-2 (iii)(Leakage current and electric strength at operating temperature) |
- |
2000 |
|
N/A |
| Cl-14.2, Table-2 (iv)(Moisture resistance) |
- |
3000 |
|
N/A |
| Cl-14.2, Table-2 (v)(Leakage current and electric strength) |
- |
2000 |
|
N/A |
| Cl-14.2, 14.3 Table-2 (vi)(Provision for earthing) |
- |
2000 |
|
N/A |
| Cl-19.11.4.1(Electrostatic discharges) |
- |
0 |
|
N/A |
| Cl-19.11.4.2(Radiated fields) |
- |
0 |
|
N/A |
| Cl-19.11.4.3(Fast transient bursts) |
- |
0 |
|
N/A |
| Cl-19.11.4.4(Surge immunity test) |
- |
0 |
|
N/A |
| Cl-19.11.4.5(Immunity to conducted discharges) |
- |
0 |
|
N/A |
| Cl-19.11.4.6(Class 3 Voltage dips and interruptions) |
- |
0 |
|
N/A |
| Cl-19.11.4.7(Harmonics) |
- |
0 |
|
N/A |
|
02 Sep, 2028 |
- Included w.e.f. 05.06.2026 |
| 5 |
IS 302 : Part 2 : Sec 15 (2009) |
Safety of household and similar electrical appliances: Part 2 particular requirements: Sec 15 appliances for heating liquids (First Revision) |
-- |
15000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6.0(Classification) |
- |
100 |
|
N/A |
| 7(Marking and instructions) |
- |
100 |
|
N/A |
| 8(Protection against live parts) |
- |
100 |
|
N/A |
| 9(STARTING OF MOTOR-OPERATED APPLIANCES) |
- |
0 |
|
N/A |
| 10(POWER INPUT AND CURRENT) |
- |
100 |
|
N/A |
| 11(HEATING) |
- |
100 |
|
N/A |
| 13(LEAKAGE CURRENT AND ELECTRIC STRENGTH AT OPERATING TEMPERATURE) |
- |
100 |
|
N/A |
| 14(TRANSIENT OVERVOLTAGES) |
- |
100 |
|
N/A |
| 15(MOISTURE RESISTANCE) |
- |
100 |
|
N/A |
| 16(LEAKAGE CURRENT AND ELECTRIC STRENGTH) |
- |
100 |
|
N/A |
| 17(OVERLOAD PROTECTION OF TRANSFORMERS AND ASSOCIATED CIRCUITS) |
- |
100 |
|
N/A |
| 18(ENDURANCE) |
- |
0 |
|
N/A |
| 19(ABNORMAL OPERATION) |
- |
100 |
|
N/A |
| 20(STABILITY AND MECHANICAL HAZARDS) |
- |
100 |
|
N/A |
| 21(MECHANICAL STRENGTH) |
- |
100 |
|
N/A |
| 22(CONSTRUCTION) |
- |
100 |
|
N/A |
| 23(INTERNAL WIRING) |
- |
100 |
|
N/A |
| 24(COMPONENTS) |
- |
100 |
|
N/A |
| 25(SUPPLY CONNECTION AND EXTERNAL FLEXIBLE CORDS) |
- |
50 |
|
N/A |
| 26(TERMINALS FOR EXTERNAL CONDUCTORS) |
- |
50 |
|
N/A |
| 27(PROVISION FOR EARTHING) |
- |
100 |
|
N/A |
| 28(SCREWS AND CONNECTIONS) |
- |
100 |
|
N/A |
| 29(CLEARANCES, CREEPAGE DISTANCES AND SOLID INSULATION) |
- |
100 |
|
N/A |
| 30(RESISTANCE TO HEAT AND FIRE) |
- |
100 |
|
N/A |
| 31(RESISTANCE TO RUSTING) |
- |
100 |
|
N/A |
| 32(RADIATION, TOXICITY AND SIMILAR HAZARDS) |
- |
0 |
|
N/A |
| 22.16(Automatic cord reel) |
- |
100 |
|
N/A |
| 22.32(Oxygen bomb for rubber material) |
- |
0 |
|
N/A |
| 22.47(Water pressure inlet) |
- |
0 |
|
N/A |
| 22.106(Interlocks) |
- |
100 |
|
N/A |
| 22.3(Flexing test) |
- |
100 |
|
N/A |
| 24(Components) |
- |
100 |
|
N/A |
| 19.11.4.1(Electrostatic discharges) |
- |
0 |
|
N/A |
| 19.11.4.2(Radiated fields) |
- |
0 |
|
N/A |
| 19.11.4.3(Fast transient bursts) |
- |
0 |
|
N/A |
| 19.11.4.4(Surge immunity test) |
- |
0 |
|
N/A |
| 19.11.4.6(Class 3 Voltage dips and interruptions) |
- |
0 |
|
N/A |
| 19.11.4.7(Harmonics) |
- |
0 |
|
N/A |
| 4(General requirements) |
- |
0 |
|
N/A |
| 5(General Conditions of tests) |
- |
0 |
|
N/A |
| 19.11.4.5(Immunity to conducted discharges) |
- |
0 |
|
N/A |
| 6(Classification- IS 302-1) |
- |
100 |
|
N/A |
| 6(Classification- IS 302-1) |
- |
100 |
|
N/A |
| 7.1(Marking- IS 302-1) |
- |
100 |
|
N/A |
| 7.1(Marking- IS 302-1) |
- |
100 |
|
N/A |
| 7.1(Marking- IS 302-1) |
- |
100 |
|
N/A |
| 7.1(Marking- IS 302-1) |
- |
100 |
|
N/A |
| 7.1(Marking- IS 302-1) |
- |
100 |
|
N/A |
| 7.1(Marking- IS 302-1) |
- |
100 |
|
N/A |
| 7.1(Marking- IS 302-1) |
- |
100 |
|
N/A |
| 7.1(Marking- IS 302-1) |
- |
100 |
|
N/A |
| 7.1(Marking- IS 302-2-15) |
- |
100 |
|
N/A |
| 7.3(Marking- IS 302-1) |
- |
100 |
|
N/A |
| 7.4(Marking- IS 302-1) |
- |
100 |
|
N/A |
| 7.5(Marking- IS 302-1) |
- |
100 |
|
N/A |
| 7.6(Marking- IS 302-1) |
- |
100 |
|
N/A |
| 7.7(Marking- IS 302-1) |
- |
100 |
|
N/A |
| 7.8(Marking- IS 302-1) |
- |
100 |
|
N/A |
| 6(Classification- IS 302-1) |
- |
100 |
|
N/A |
| 6(Classification- IS 302-1) |
- |
100 |
|
N/A |
| 7.1(Marking- IS 302-1) |
- |
100 |
|
N/A |
| 7.1(Marking- IS 302-1) |
- |
100 |
|
N/A |
| 7.1(Marking- IS 302-1) |
- |
100 |
|
N/A |
| 7.1(Marking- IS 302-1) |
- |
100 |
|
N/A |
| 7.1(Marking- IS 302-1) |
- |
100 |
|
N/A |
| 7.1(Marking- IS 302-1) |
- |
100 |
|
N/A |
| 7.1(Marking- IS 302-1) |
- |
100 |
|
N/A |
| Marking- IS 302-1(Marking- IS 302-1) |
- |
100 |
|
N/A |
| 7.1(Marking- IS 302-2-15) |
- |
100 |
|
N/A |
| 7.3(Marking- IS 302-1) |
- |
100 |
|
N/A |
| 7.4(Marking- IS 302-1) |
- |
100 |
|
N/A |
| 7.5(Marking- IS 302-1) |
- |
100 |
|
N/A |
| 7.6(Marking- IS 302-1) |
- |
100 |
|
N/A |
| 7.7(Marking- IS 302-1) |
- |
100 |
|
N/A |
| 7.8(Marking- IS 302-1) |
- |
100 |
|
N/A |
| 7.9(Marking- IS 302-1) |
- |
100 |
|
N/A |
| 7.1O(Marking- IS 302-1) |
- |
100 |
|
N/A |
| 7.11(Marking- IS 302-1) |
- |
100 |
|
N/A |
| 7.12(Marking- IS 302-2-15) |
- |
100 |
|
N/A |
| 7.12(Marking- IS 302-1) |
- |
100 |
|
N/A |
| 7.12.1(Marking- IS 302-1) |
- |
100 |
|
N/A |
| 7.12.3(Marking- IS 302-1) |
- |
100 |
|
N/A |
| 7.12.5(Marking- IS 302-1) |
- |
100 |
|
N/A |
| 7.12.6(Marking- IS 302-1) |
- |
100 |
|
N/A |
| 7.13(Marking- IS 302-1) |
- |
100 |
|
N/A |
| 7.14(Marking- IS 302-1) |
- |
100 |
|
N/A |
| 7.15(Marking- IS 302-1) |
- |
100 |
|
N/A |
| 7.101(Marking- IS 302-2-15) |
- |
100 |
|
N/A |
| 8(Protection Against Electric Shock, IS 302-1) |
- |
100 |
|
N/A |
| 10(Power Input and Current, IS 302-1) |
- |
100 |
|
N/A |
| 11(Heating, IS 302-1) |
- |
100 |
|
N/A |
| 11(Heating, IS 302-1) |
- |
100 |
|
N/A |
| 11(Heating, IS 302-1) |
- |
200 |
|
N/A |
| 11(Heating, IS 302-1) |
- |
100 |
|
N/A |
| 13(Electrical Insulation and Leakage Current at Operating Temperature: Leakage current, IS 302-1) |
- |
100 |
|
N/A |
| 13(Electrical Insulation and Leakage Current at Operating Temperature: High Voltage, IS 302-1) |
- |
100 |
|
N/A |
| 15.1(Moisture Resistance, IS 302-1) |
- |
100 |
|
N/A |
| 15.2(Spillage test as 15.2, IS 3.02-1 & 302-2-15) |
- |
100 |
|
N/A |
| 16(Leakage current as per Cl 16, IS 302-1) |
- |
100 |
|
N/A |
| 16(electric strength as per Cl 16, IS 302-1) |
- |
100 |
|
N/A |
| 17(Overload protection of Transformers and Associated Circuits, IS 302-1) |
- |
100 |
|
N/A |
| 19.13(Abnormal Operation as per Cl 19, IS 302-2-15) |
- |
100 |
|
N/A |
| 19.13(Abnormal Operation as per Cl 19, IS 302-1) |
- |
100 |
|
N/A |
| 19.13(Abnormal Operation as per Cl 19, IS 302-1) |
- |
100 |
|
N/A |
| 19.13(Abnormal Operation as per Cl 19, IS 302-1) |
- |
100 |
|
N/A |
| 20.1(Stability & Mechanical Hazards, IS 302-1) |
- |
100 |
|
N/A |
| 21.1(Mechanical Strength, IS 302-1) |
- |
100 |
|
N/A |
| 21.2(Mechanical Strength, IS 302-1) |
- |
100 |
|
N/A |
| 22.1(Construction, IS 302-1) |
- |
100 |
|
N/A |
| 22.7(Construction as per Cl 22.7, IS 3.02-2-15) |
- |
100 |
|
N/A |
| 22.107(Construction as per Cl 22.7, IS 3.02-2-15) |
- |
100 |
|
N/A |
| 22.108(Construction as per Cl 22.8, IS 3.02-2-15) |
- |
100 |
|
N/A |
| 23.1(Internal Wiring, IS 302-1) |
- |
100 |
|
N/A |
| 23.2(Internal Wiring, IS 302-1) |
- |
100 |
|
N/A |
| 23.4(Internal Wiring, IS 302-1) |
- |
100 |
|
N/A |
| 23.5(Internal Wiring, IS 302-1) |
- |
100 |
|
N/A |
| 23.6(Internal Wiring, IS 302-1) |
- |
100 |
|
N/A |
| 23.7(Internal Wiring, IS 302-1) |
- |
100 |
|
N/A |
| 23.8(Internal Wiring, IS 302-1) |
- |
100 |
|
N/A |
| 23.9(Internal Wiring, IS 302-1) |
- |
100 |
|
N/A |
| 23.1O(Internal Wiring, IS 302-1) |
- |
100 |
|
N/A |
| 25.1(Supply Connection and External Flexible Cords, IS 302-1) |
- |
100 |
|
N/A |
| 25.2(Supply Connection and External Flexible Cords, IS 302-1) |
- |
100 |
|
N/A |
| 25.5(Supply Connection and External Flexible Cords, IS 302-1) |
- |
100 |
|
N/A |
| 25.6(Supply Connection and External Flexible Cords, IS 302-1) |
- |
100 |
|
N/A |
| 25.8(Supply Connection and External Flexible Cords, IS 302-1) |
- |
100 |
|
N/A |
| 25.9(Supply Connection and External Flexible Cords, IS 302-1) |
- |
100 |
|
N/A |
| 25.1(Supply Connection and External Flexible Cords, IS 302-1) |
- |
100 |
|
N/A |
| 25.11(Supply Connection and External Flexible Cords, IS 302-1) |
- |
100 |
|
N/A |
| 25.12(Supply Connection and External Flexible Cords, IS 302-1) |
- |
100 |
|
N/A |
| 25.13(Supply Connection and External Flexible Cords, IS 302-1) |
- |
100 |
|
N/A |
| 25.14(Supply Connection and External Flexible Cords, IS 302-1) |
- |
100 |
|
N/A |
| 25.14(Supply Connection and External Flexible Cords, IS 302-1) |
- |
100 |
|
N/A |
| 25.15(Supply Connection and External Flexible Cords, IS 302-1) |
- |
100 |
|
N/A |
| 25.16(Supply Connection and External Flexible Cords, IS 302-1) |
- |
100 |
|
N/A |
| 25.17(Supply Connection and External Flexible Cords, IS 302-1) |
- |
100 |
|
N/A |
| 25.18(Supply Connection and External Flexible Cords, IS 302-1) |
- |
100 |
|
N/A |
| 25.19(Supply Connection and External Flexible Cords, IS 302-1) |
- |
100 |
|
N/A |
| 25.2(Supply Connection and External Flexible Cords, IS 302-1) |
- |
100 |
|
N/A |
| 25.21(Supply Connection and External Flexible Cords, IS 302-1) |
- |
100 |
|
N/A |
| 25.22(Supply Connection and External Flexible Cords, IS 302-1) |
- |
100 |
|
N/A |
| 26(Terminals for External Conductors, IS 302-1) |
- |
100 |
|
N/A |
| 27.1(Provision for Earthing, IS 302-1) |
- |
100 |
|
N/A |
| 27.2(Provision for Earthing, IS 302-1) |
- |
100 |
|
N/A |
| 27.3(Provision for Earthing, IS 302-1) |
- |
100 |
|
N/A |
| 27.4(Provision for Earthing, IS 302-1) |
- |
100 |
|
N/A |
| 27.5(Provision for Earthing, IS 302-1) |
- |
100 |
|
N/A |
| 28(Screws & Connections, IS 302-1) |
- |
100 |
|
N/A |
| 29.1(Clearances, Creepage distances and Solid Insulation, IS 302-1) |
- |
100 |
|
N/A |
| 29.2(Clearances, Creepage distances and Solid Insulation, IS 302-1) |
- |
100 |
|
N/A |
| 30.1(Resistance to Heat and Fire, IS 302-1) |
- |
100 |
|
N/A |
| 30.2(Resistance to Heat and Fire, IS 302-1) |
- |
100 |
|
N/A |
| 31(Resistance of Rusting, IS 302-1) |
- |
100 |
|
N/A |
| Cl. 15.02(stands for cordless kettles) |
- |
100 |
|
N/A |
| Cl.22.103(appliance coupler of cordless kettles) |
- |
100 |
|
N/A |
| Cl-19.3(Abnormal operation test) |
- |
100 |
|
N/A |
| Cl-19.101("Abnormal operation test
") |
- |
100 |
|
N/A |
| Cl-19.102("Abnormal operation test
") |
- |
100 |
|
N/A |
| Cl-19.103("Abnormal operation test
") |
- |
100 |
|
N/A |
| Cl-22.103(Construction) |
- |
100 |
|
N/A |
| Cl-25.101(" Supply connection And external flexible ") |
- |
100 |
|
N/A |
| 6.0(Classification) |
- |
- |
|
- |
| 7(Marking and instructions) |
- |
- |
|
- |
| 8(Protection against live parts) |
- |
- |
|
- |
| 9(STARTING OF MOTOR-OPERATED APPLIANCES) |
- |
- |
|
- |
| 10(POWER INPUT AND CURRENT) |
- |
- |
|
- |
| 11(HEATING) |
- |
- |
|
- |
| 13(LEAKAGE CURRENT AND ELECTRIC STRENGTH AT OPERATING TEMPERATURE) |
- |
- |
|
- |
| 14(TRANSIENT OVERVOLTAGES) |
- |
- |
|
- |
| 15(MOISTURE RESISTANCE) |
- |
- |
|
- |
| 16(LEAKAGE CURRENT AND ELECTRIC STRENGTH) |
- |
- |
|
- |
| 17(OVERLOAD PROTECTION OF TRANSFORMERS AND ASSOCIATED CIRCUITS) |
- |
- |
|
- |
| 18(ENDURANCE) |
- |
- |
|
- |
| 19(ABNORMAL OPERATION) |
- |
- |
|
- |
| 20(STABILITY AND MECHANICAL HAZARDS) |
- |
- |
|
- |
| 21(MECHANICAL STRENGTH) |
- |
- |
|
- |
| 22(CONSTRUCTION) |
- |
- |
|
- |
| 23(INTERNAL WIRING) |
- |
- |
|
- |
| 24(COMPONENTS) |
- |
- |
|
- |
| 25(SUPPLY CONNECTION AND EXTERNAL FLEXIBLE CORDS) |
- |
- |
|
- |
| 26(TERMINALS FOR EXTERNAL CONDUCTORS) |
- |
- |
|
- |
| 27(PROVISION FOR EARTHING) |
- |
- |
|
- |
| 28(SCREWS AND CONNECTIONS) |
- |
- |
|
- |
| 29(CLEARANCES, CREEPAGE DISTANCES AND SOLID INSULATION) |
- |
- |
|
- |
| 30(RESISTANCE TO HEAT AND FIRE) |
- |
- |
|
- |
| 31(RESISTANCE TO RUSTING) |
- |
- |
|
- |
| 32(RADIATION, TOXICITY AND SIMILAR HAZARDS) |
- |
- |
|
- |
| 22.16(Automatic cord reel) |
- |
- |
|
- |
| 22.32(Oxygen bomb for rubber material) |
- |
- |
|
- |
| 22.47(Water pressure inlet) |
- |
- |
|
- |
| 22.106(Interlocks) |
- |
- |
|
- |
| 22.3(Flexing test) |
- |
- |
|
- |
| 24(Components) |
- |
- |
|
- |
| 19.11.4.1(Electrostatic discharges) |
- |
- |
|
- |
| 19.11.4.2(Radiated fields) |
- |
- |
|
- |
| 19.11.4.3(Fast transient bursts) |
- |
- |
|
- |
| 19.11.4.4(Surge immunity test) |
- |
- |
|
- |
| 19.11.4.6(Class 3 Voltage dips and interruptions) |
- |
- |
|
- |
| 19.11.4.7(Harmonics) |
- |
- |
|
- |
| 4(General requirements) |
- |
- |
|
- |
| 5(General Conditions of tests) |
- |
- |
|
- |
| 19.11.4.5(Immunity to conducted discharges) |
- |
- |
|
- |
| 6(Classification- IS 302-1) |
- |
- |
|
- |
| 6(Classification- IS 302-1) |
- |
- |
|
- |
| 7.1(Marking- IS 302-1) |
- |
- |
|
- |
| 7.1(Marking- IS 302-1) |
- |
- |
|
- |
| 7.1(Marking- IS 302-1) |
- |
- |
|
- |
| 7.1(Marking- IS 302-1) |
- |
- |
|
- |
| 7.1(Marking- IS 302-1) |
- |
- |
|
- |
| 7.1(Marking- IS 302-1) |
- |
- |
|
- |
| 7.1(Marking- IS 302-1) |
- |
- |
|
- |
| 7.1(Marking- IS 302-1) |
- |
- |
|
- |
| 7.1(Marking- IS 302-2-15) |
- |
- |
|
- |
| 7.3(Marking- IS 302-1) |
- |
- |
|
- |
| 7.4(Marking- IS 302-1) |
- |
- |
|
- |
| 7.5(Marking- IS 302-1) |
- |
- |
|
- |
| 7.6(Marking- IS 302-1) |
- |
- |
|
- |
| 7.7(Marking- IS 302-1) |
- |
- |
|
- |
| 7.8(Marking- IS 302-1) |
- |
- |
|
- |
| 6(Classification- IS 302-1) |
- |
- |
|
- |
| 6(Classification- IS 302-1) |
- |
- |
|
- |
| 7.1(Marking- IS 302-1) |
- |
- |
|
- |
| 7.1(Marking- IS 302-1) |
- |
- |
|
- |
| 7.1(Marking- IS 302-1) |
- |
- |
|
- |
| 7.1(Marking- IS 302-1) |
- |
- |
|
- |
| 7.1(Marking- IS 302-1) |
- |
- |
|
- |
| 7.1(Marking- IS 302-1) |
- |
- |
|
- |
| 7.1(Marking- IS 302-1) |
- |
- |
|
- |
| Marking- IS 302-1(Marking- IS 302-1) |
- |
- |
|
- |
| 7.1(Marking- IS 302-2-15) |
- |
- |
|
- |
| 7.3(Marking- IS 302-1) |
- |
- |
|
- |
| 7.4(Marking- IS 302-1) |
- |
- |
|
- |
| 7.5(Marking- IS 302-1) |
- |
- |
|
- |
| 7.6(Marking- IS 302-1) |
- |
- |
|
- |
| 7.7(Marking- IS 302-1) |
- |
- |
|
- |
| 7.8(Marking- IS 302-1) |
- |
- |
|
- |
| 7.9(Marking- IS 302-1) |
- |
- |
|
- |
| 7.1O(Marking- IS 302-1) |
- |
- |
|
- |
| 7.11(Marking- IS 302-1) |
- |
- |
|
- |
| 7.12(Marking- IS 302-2-15) |
- |
- |
|
- |
| 7.12(Marking- IS 302-1) |
- |
- |
|
- |
| 7.12.1(Marking- IS 302-1) |
- |
- |
|
- |
| 7.12.3(Marking- IS 302-1) |
- |
- |
|
- |
| 7.12.5(Marking- IS 302-1) |
- |
- |
|
- |
| 7.12.6(Marking- IS 302-1) |
- |
- |
|
- |
| 7.13(Marking- IS 302-1) |
- |
- |
|
- |
| 7.14(Marking- IS 302-1) |
- |
- |
|
- |
| 7.15(Marking- IS 302-1) |
- |
- |
|
- |
| 7.101(Marking- IS 302-2-15) |
- |
- |
|
- |
| 8(Protection Against Electric Shock, IS 302-1) |
- |
- |
|
- |
| 10(Power Input and Current, IS 302-1) |
- |
- |
|
- |
| 11(Heating, IS 302-1) |
- |
- |
|
- |
| 11(Heating, IS 302-1) |
- |
- |
|
- |
| 11(Heating, IS 302-1) |
- |
- |
|
- |
| 11(Heating, IS 302-1) |
- |
- |
|
- |
| 13(Electrical Insulation and Leakage Current at Operating Temperature: Leakage current, IS 302-1) |
- |
- |
|
- |
| 13(Electrical Insulation and Leakage Current at Operating Temperature: High Voltage, IS 302-1) |
- |
- |
|
- |
| 15.1(Moisture Resistance, IS 302-1) |
- |
- |
|
- |
| 15.2(Spillage test as 15.2, IS 3.02-1 & 302-2-15) |
- |
- |
|
- |
| 16(Leakage current as per Cl 16, IS 302-1) |
- |
- |
|
- |
| 16(electric strength as per Cl 16, IS 302-1) |
- |
- |
|
- |
| 17(Overload protection of Transformers and Associated Circuits, IS 302-1) |
- |
- |
|
- |
| 19.13(Abnormal Operation as per Cl 19, IS 302-2-15) |
- |
- |
|
- |
| 19.13(Abnormal Operation as per Cl 19, IS 302-1) |
- |
- |
|
- |
| 19.13(Abnormal Operation as per Cl 19, IS 302-1) |
- |
- |
|
- |
| 19.13(Abnormal Operation as per Cl 19, IS 302-1) |
- |
- |
|
- |
| 20.1(Stability & Mechanical Hazards, IS 302-1) |
- |
- |
|
- |
| 21.1(Mechanical Strength, IS 302-1) |
- |
- |
|
- |
| 21.2(Mechanical Strength, IS 302-1) |
- |
- |
|
- |
| 22.1(Construction, IS 302-1) |
- |
- |
|
- |
| 22.7(Construction as per Cl 22.7, IS 3.02-2-15) |
- |
- |
|
- |
| 22.107(Construction as per Cl 22.7, IS 3.02-2-15) |
- |
- |
|
- |
| 22.108(Construction as per Cl 22.8, IS 3.02-2-15) |
- |
- |
|
- |
| 23.1(Internal Wiring, IS 302-1) |
- |
- |
|
- |
| 23.2(Internal Wiring, IS 302-1) |
- |
- |
|
- |
| 23.4(Internal Wiring, IS 302-1) |
- |
- |
|
- |
| 23.5(Internal Wiring, IS 302-1) |
- |
- |
|
- |
| 23.6(Internal Wiring, IS 302-1) |
- |
- |
|
- |
| 23.7(Internal Wiring, IS 302-1) |
- |
- |
|
- |
| 23.8(Internal Wiring, IS 302-1) |
- |
- |
|
- |
| 23.9(Internal Wiring, IS 302-1) |
- |
- |
|
- |
| 23.1O(Internal Wiring, IS 302-1) |
- |
- |
|
- |
| 25.1(Supply Connection and External Flexible Cords, IS 302-1) |
- |
- |
|
- |
| 25.2(Supply Connection and External Flexible Cords, IS 302-1) |
- |
- |
|
- |
| 25.5(Supply Connection and External Flexible Cords, IS 302-1) |
- |
- |
|
- |
| 25.6(Supply Connection and External Flexible Cords, IS 302-1) |
- |
- |
|
- |
| 25.8(Supply Connection and External Flexible Cords, IS 302-1) |
- |
- |
|
- |
| 25.9(Supply Connection and External Flexible Cords, IS 302-1) |
- |
- |
|
- |
| 25.1(Supply Connection and External Flexible Cords, IS 302-1) |
- |
- |
|
- |
| 25.11(Supply Connection and External Flexible Cords, IS 302-1) |
- |
- |
|
- |
| 25.12(Supply Connection and External Flexible Cords, IS 302-1) |
- |
- |
|
- |
| 25.13(Supply Connection and External Flexible Cords, IS 302-1) |
- |
- |
|
- |
| 25.14(Supply Connection and External Flexible Cords, IS 302-1) |
- |
- |
|
- |
| 25.14(Supply Connection and External Flexible Cords, IS 302-1) |
- |
- |
|
- |
| 25.15(Supply Connection and External Flexible Cords, IS 302-1) |
- |
- |
|
- |
| 25.16(Supply Connection and External Flexible Cords, IS 302-1) |
- |
- |
|
- |
| 25.17(Supply Connection and External Flexible Cords, IS 302-1) |
- |
- |
|
- |
| 25.18(Supply Connection and External Flexible Cords, IS 302-1) |
- |
- |
|
- |
| 25.19(Supply Connection and External Flexible Cords, IS 302-1) |
- |
- |
|
- |
| 25.2(Supply Connection and External Flexible Cords, IS 302-1) |
- |
- |
|
- |
| 25.21(Supply Connection and External Flexible Cords, IS 302-1) |
- |
- |
|
- |
| 25.22(Supply Connection and External Flexible Cords, IS 302-1) |
- |
- |
|
- |
| 26(Terminals for External Conductors, IS 302-1) |
- |
- |
|
- |
| 27.1(Provision for Earthing, IS 302-1) |
- |
- |
|
- |
| 27.2(Provision for Earthing, IS 302-1) |
- |
- |
|
- |
| 27.3(Provision for Earthing, IS 302-1) |
- |
- |
|
- |
| 27.4(Provision for Earthing, IS 302-1) |
- |
- |
|
- |
| 27.5(Provision for Earthing, IS 302-1) |
- |
- |
|
- |
| 28(Screws & Connections, IS 302-1) |
- |
- |
|
- |
| 29.1(Clearances, Creepage distances and Solid Insulation, IS 302-1) |
- |
- |
|
- |
| 29.2(Clearances, Creepage distances and Solid Insulation, IS 302-1) |
- |
- |
|
- |
| 30.1(Resistance to Heat and Fire, IS 302-1) |
- |
- |
|
- |
| 30.2(Resistance to Heat and Fire, IS 302-1) |
- |
- |
|
- |
| 31(Resistance of Rusting, IS 302-1) |
- |
- |
|
- |
| Cl. 15.02(stands for cordless kettles) |
- |
- |
|
- |
| Cl.22.103(appliance coupler of cordless kettles) |
- |
- |
|
- |
| Cl-19.3(Abnormal operation test) |
- |
- |
|
- |
| Cl-19.101("Abnormal operation test
") |
- |
- |
|
- |
| Cl-19.102("Abnormal operation test
") |
- |
- |
|
- |
| Cl-19.103("Abnormal operation test
") |
- |
- |
|
- |
| Cl-22.103(Construction) |
- |
- |
|
- |
| Cl-25.101(" Supply connection And external flexible ") |
- |
- |
|
- |
|
02 Sep, 2028 |
- Included w.e.f. 24.03.2026
Exclusion: "32 (RADIATION, TOXICITY AND SIMILAR HAZARDS)
19.11.4.1 (Electrostatic discharges)
19.11.4.2 (Radiated fields)
19.11.4.3 (Fast transient bursts)
19.11.4.4 (Surge immunity test)
19.11.4.5 (Immunity to conducted discharges)
19.11.4.6 (Class 3 Voltage dips and interruptions)
19.11.4.7 (Harmonics)
22.32 (Oxygen bomb for rubber material)
" |
| 6 |
IS 302 : Part 2 : Sec 14 (2009) |
Safety of household and similar electrical appliances: Part 2 particular requirements: Sec 14 electric kitchen machines (First Revision) |
-- |
15000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6(Classification- IS 302-1 ) |
- |
100 |
|
N/A |
| 6(Classification- IS 302-1) |
- |
100 |
|
N/A |
| 7.1(Marking- IS 302-1) |
- |
100 |
|
N/A |
| 7.1(Marking- IS 302-1) |
- |
100 |
|
N/A |
| 7.1(Marking- IS 302-1) |
- |
100 |
|
N/A |
| 7.1(Marking- IS 302-1) |
- |
100 |
|
N/A |
| 7.1(Marking- IS 302-1) |
- |
100 |
|
N/A |
| 7.1(Marking- IS 302-1) |
- |
100 |
|
N/A |
| 7.1(Marking- IS 302-1) |
- |
100 |
|
N/A |
| 7.1(Marking- IS 302-1) |
- |
100 |
|
N/A |
| 7.3(Marking- IS 302-1) |
- |
100 |
|
N/A |
| 7.4(Marking- IS 302-1) |
- |
100 |
|
N/A |
| 7.6(Marking- IS 302-1) |
- |
100 |
|
N/A |
| 7.7(Marking- IS 302-1) |
- |
100 |
|
N/A |
| 7.8(Marking- IS 302-1) |
- |
100 |
|
N/A |
| 7.11(Marking- IS 302-1) |
- |
100 |
|
N/A |
| 7.12(Marking- IS 302-1) |
- |
100 |
|
N/A |
| 7.13(Marking- IS 302-1) |
- |
100 |
|
N/A |
| 7.14(Marking- IS 302-1) |
- |
100 |
|
N/A |
| 7.15(Marking- IS 302-1) |
- |
100 |
|
N/A |
| 7.101(Marking) |
- |
100 |
|
N/A |
| 8( Protection Against Electric Shock, IS 302-1) |
- |
300 |
|
N/A |
| 10(Power Input and Current, IS 302-1) |
- |
300 |
|
N/A |
| 11(Heating, IS 302-1) |
- |
200 |
|
N/A |
| 11(Heating, IS 302-1) |
- |
100 |
|
N/A |
| 11(Heating, IS 302-1) |
- |
100 |
|
N/A |
| 11(Heating, IS 302-1) |
- |
100 |
|
N/A |
| 11(Heating, IS 302-1) |
- |
100 |
|
N/A |
| 13(Electrical Insulation and Leakage Current at Operating Temperature: Leakage current, IS 302-1) |
- |
300 |
|
N/A |
| 13(Electrical Insulation and Leakage Current at Operating Temperature: High Voltage, IS 302-1) |
- |
100 |
|
N/A |
| 14(Transient Over Voltages, IS 302-1) |
- |
500 |
|
N/A |
| 15.1(Moisture Resistance, IS 302-1) |
- |
300 |
|
N/A |
| 15.2(Moisture Resistance, IS 302-1) |
- |
100 |
|
N/A |
| 15(Moisture Resistance, IS 302-1) |
- |
100 |
|
N/A |
| 16(Electrical Insulation and Leakage Current at Operating Temperature: Leakage current, IS 302-1) |
- |
100 |
|
N/A |
| 16(Electrical Insulation and Leakage Current at Operating Temperature: High Voltage, IS 302-1) |
- |
100 |
|
N/A |
| 17(Overload protection of Transformers and Associated Circuits, IS 302-1) |
- |
200 |
|
N/A |
| 17(Overload protection of Transformers and Associated Circuits, IS 302-1) |
- |
300 |
|
N/A |
| 19.7(Abnormal Operation, IS 302-1) |
- |
300 |
|
N/A |
| 19.8(Abnormal Operation, IS 302-1) |
- |
200 |
|
N/A |
| 19.9(Abnormal Operation, IS 302-1) |
- |
200 |
|
N/A |
| 19.1(Abnormal Operation, IS 302-1) |
- |
200 |
|
N/A |
| 19.101(Abnormal Operation) |
- |
200 |
|
N/A |
| 19.102(Abnormal Operation) |
- |
100 |
|
N/A |
| 20.1(Stability & Mechanical Hazards, IS 302-1) |
- |
200 |
|
N/A |
| 20.2(Stability & Mechanical Hazards, IS 302-1) |
- |
200 |
|
N/A |
| 20.101(Stability & Mechanical Hazards) |
- |
100 |
|
N/A |
| 20.102(Stability & Mechanical Hazards) |
- |
100 |
|
N/A |
| 20.103(Stability & Mechanical Hazards) |
- |
200 |
|
N/A |
| 20.104(Stability & Mechanical Hazards) |
- |
200 |
|
N/A |
| 20.105(Stability & Mechanical Hazards) |
- |
100 |
|
N/A |
| 20.106(Stability & Mechanical Hazards) |
- |
100 |
|
N/A |
| 20.107(Stability & Mechanical Hazards) |
- |
200 |
|
N/A |
| 20.108(Stability & Mechanical Hazards) |
- |
100 |
|
N/A |
| 20.109(Stability & Mechanical Hazards) |
- |
100 |
|
N/A |
| 20.110(Stability & Mechanical Hazards) |
- |
200 |
|
N/A |
| 20.111(Stability & Mechanical Hazards) |
- |
100 |
|
N/A |
| 20.112(Stability & Mechanical Hazards) |
- |
100 |
|
N/A |
| 20.113(Stability & Mechanical Hazards) |
- |
100 |
|
N/A |
| 20.114(Stability & Mechanical Hazards) |
- |
100 |
|
N/A |
| 20.115(Stability & Mechanical Hazards) |
- |
100 |
|
N/A |
| 20.116(Stability & Mechanical Hazards) |
- |
100 |
|
N/A |
| 21.1(Mechanical Strength, IS 302-1) |
- |
300 |
|
N/A |
| 21.2(Mechanical Strength, IS 302-1) |
- |
200 |
|
N/A |
| 22(Construction, IS 302-1) |
- |
100 |
|
N/A |
| 22.101(Construction) |
- |
100 |
|
N/A |
| 22.102(Construction) |
- |
100 |
|
N/A |
| 23.1(Internal Wiring, IS 302-1) |
- |
100 |
|
N/A |
| 23.2(Internal Wiring, IS 302-1) |
- |
200 |
|
N/A |
| 23.3(Internal Wiring, IS 302-1) |
- |
100 |
|
N/A |
| 23.4(Internal Wiring, IS 302-1) |
- |
100 |
|
N/A |
| 23.5(Internal Wiring, IS 302-1) |
- |
100 |
|
N/A |
| 23.6(Internal Wiring, IS 302-1) |
- |
100 |
|
N/A |
| 23.7(Internal Wiring, IS 302-1) |
- |
100 |
|
N/A |
| 23.8(Internal Wiring, IS 302-1) |
- |
100 |
|
N/A |
| 23.9(Internal Wiring, IS 302-1) |
- |
100 |
|
N/A |
| 23.10(Internal Wiring, IS 302-1) |
- |
100 |
|
N/A |
| 24.1(Components, IS 302-1) |
- |
100 |
|
N/A |
| 24.2(Components, IS 302-1) |
- |
100 |
|
N/A |
| 24.5(Components, IS 302-1) |
- |
200 |
|
N/A |
| 24.6(Components, IS 302-1) |
- |
100 |
|
N/A |
| 25.1(Supply Connection and External Flexible Cords, IS 302-1) |
- |
100 |
|
N/A |
| 25.5(Supply Connection and External Flexible Cords, IS 302-1) |
- |
100 |
|
N/A |
| 25.6(Supply Connection and External Flexible Cords, IS 302-1) |
- |
100 |
|
N/A |
| 25.7(Supply Connection and External Flexible Cords, IS 302-1) |
- |
100 |
|
N/A |
| 25.8(Supply Connection and External Flexible Cords, IS 302-1) |
- |
100 |
|
N/A |
| 26.9(Supply Connection and External Flexible Cords, IS 302-1) |
- |
100 |
|
N/A |
| 25.1(Supply Connection and External Flexible Cords, IS 302-1) |
- |
100 |
|
N/A |
| 25.11(Supply Connection and External Flexible Cords, IS 302-1) |
- |
100 |
|
N/A |
| 25.12(Supply Connection and External Flexible Cords, IS 302-1) |
- |
200 |
|
N/A |
| 25.13(Supply Connection and External Flexible Cords, IS 302-1) |
- |
100 |
|
N/A |
| 25.14(Supply Connection and External Flexible Cords, IS 302-1) |
- |
100 |
|
N/A |
| 25.14(Supply Connection and External Flexible Cords, IS 302-1) |
- |
100 |
|
N/A |
| 25.15(Supply Connection and External Flexible Cords, IS 302-1) |
- |
100 |
|
N/A |
| 25.16(Supply Connection and External Flexible Cords, IS 302-1) |
- |
100 |
|
N/A |
| 25.17(Supply Connection and External Flexible Cords, IS 302-1) |
- |
100 |
|
N/A |
| 25.18(Supply Connection and External Flexible Cords, IS 302-1) |
- |
100 |
|
N/A |
| 25.19(Supply Connection and External Flexible Cords, IS 302-1) |
- |
100 |
|
N/A |
| 25.2(Supply Connection and External Flexible Cords, IS 302-1) |
- |
100 |
|
N/A |
| 25.21(Supply Connection and External Flexible Cords, IS 302-1) |
- |
100 |
|
N/A |
| 25.22(Supply Connection and External Flexible Cords, IS 302-1) |
- |
100 |
|
N/A |
| 26(Terminals for External Conductors, IS 302-1) |
- |
200 |
|
N/A |
| 27(Provision for Earthing, IS 302-1) |
- |
100 |
|
N/A |
| 27.2(Provision for Earthing, IS 302-1) |
- |
100 |
|
N/A |
| 27.3(Provision for Earthing, IS 302-1) |
- |
100 |
|
N/A |
| 27.4(Provision for Earthing, IS 302-1) |
- |
100 |
|
N/A |
| 27.5(Provision for Earthing, IS 302-1) |
- |
100 |
|
N/A |
| 28(Screws & Connections, IS 302-1) |
- |
100 |
|
N/A |
| 29.1(Clearances, Creepage distances and Solid Insulation, IS 302-1) |
- |
100 |
|
N/A |
| 29.2(Clearances, Creepage distances and Solid Insulation, IS 302-1) |
- |
100 |
|
N/A |
| 30.1(Resistance to Heat and Fire, IS 302-1) |
- |
100 |
|
N/A |
| 30.2(Resistance to Heat and Fire, IS 302-1) |
- |
100 |
|
N/A |
| 31(Resistance of Rusting, IS 302-1) |
- |
100 |
|
N/A |
| 32(Radiation, Toxicity and similar Hazard IS 302-1) |
- |
0 |
|
N/A |
| 19.11.4.1(Electrostatic discharges) |
- |
0 |
|
N/A |
| 19.11.4.2(Radiated fields) |
- |
0 |
|
N/A |
| 19.11.4.3(Fast transient bursts) |
- |
0 |
|
N/A |
| 19.11.4.4(Surge immunity test) |
- |
0 |
|
N/A |
| 19.11.4.5(Immunity to conducted discharges) |
- |
0 |
|
N/A |
| 19.11.4.6(Class 3 Voltage dips and interruptions) |
- |
0 |
|
N/A |
| 19.11.4.7(Harmonics) |
- |
0 |
|
N/A |
| 19.11.4.5(Immunity to conducted discharges) |
- |
0 |
|
N/A |
| 4(GENERAL REQUIREMENTS) |
- |
0 |
|
N/A |
| 5(GENERAL CONDITIONS FOR THE TESTS) |
- |
0 |
|
N/A |
| 27(Provision for Earthing) |
- |
100 |
|
N/A |
| 29(Clearances, Creepage distances and Solid Insulation) |
- |
100 |
|
N/A |
| 6(Classification- IS 302-1 ) |
- |
- |
|
- |
| 6(Classification- IS 302-1) |
- |
- |
|
- |
| 7.1(Marking- IS 302-1) |
- |
- |
|
- |
| 7.1(Marking- IS 302-1) |
- |
- |
|
- |
| 7.1(Marking- IS 302-1) |
- |
- |
|
- |
| 7.1(Marking- IS 302-1) |
- |
- |
|
- |
| 7.1(Marking- IS 302-1) |
- |
- |
|
- |
| 7.1(Marking- IS 302-1) |
- |
- |
|
- |
| 7.1(Marking- IS 302-1) |
- |
- |
|
- |
| 7.1(Marking- IS 302-1) |
- |
- |
|
- |
| 7.3(Marking- IS 302-1) |
- |
- |
|
- |
| 7.4(Marking- IS 302-1) |
- |
- |
|
- |
| 7.6(Marking- IS 302-1) |
- |
- |
|
- |
| 7.7(Marking- IS 302-1) |
- |
- |
|
- |
| 7.8(Marking- IS 302-1) |
- |
- |
|
- |
| 7.11(Marking- IS 302-1) |
- |
- |
|
- |
| 7.12(Marking- IS 302-1) |
- |
- |
|
- |
| 7.13(Marking- IS 302-1) |
- |
- |
|
- |
| 7.14(Marking- IS 302-1) |
- |
- |
|
- |
| 7.15(Marking- IS 302-1) |
- |
- |
|
- |
| 7.101(Marking) |
- |
- |
|
- |
| 8( Protection Against Electric Shock, IS 302-1) |
- |
- |
|
- |
| 10(Power Input and Current, IS 302-1) |
- |
- |
|
- |
| 11(Heating, IS 302-1) |
- |
- |
|
- |
| 11(Heating, IS 302-1) |
- |
- |
|
- |
| 11(Heating, IS 302-1) |
- |
- |
|
- |
| 11(Heating, IS 302-1) |
- |
- |
|
- |
| 11(Heating, IS 302-1) |
- |
- |
|
- |
| 13(Electrical Insulation and Leakage Current at Operating Temperature: Leakage current, IS 302-1) |
- |
- |
|
- |
| 13(Electrical Insulation and Leakage Current at Operating Temperature: High Voltage, IS 302-1) |
- |
- |
|
- |
| 14(Transient Over Voltages, IS 302-1) |
- |
- |
|
- |
| 15.1(Moisture Resistance, IS 302-1) |
- |
- |
|
- |
| 15.2(Moisture Resistance, IS 302-1) |
- |
- |
|
- |
| 15(Moisture Resistance, IS 302-1) |
- |
- |
|
- |
| 16(Electrical Insulation and Leakage Current at Operating Temperature: Leakage current, IS 302-1) |
- |
- |
|
- |
| 16(Electrical Insulation and Leakage Current at Operating Temperature: High Voltage, IS 302-1) |
- |
- |
|
- |
| 17(Overload protection of Transformers and Associated Circuits, IS 302-1) |
- |
- |
|
- |
| 17(Overload protection of Transformers and Associated Circuits, IS 302-1) |
- |
- |
|
- |
| 19.7(Abnormal Operation, IS 302-1) |
- |
- |
|
- |
| 19.8(Abnormal Operation, IS 302-1) |
- |
- |
|
- |
| 19.9(Abnormal Operation, IS 302-1) |
- |
- |
|
- |
| 19.1(Abnormal Operation, IS 302-1) |
- |
- |
|
- |
| 19.101(Abnormal Operation) |
- |
- |
|
- |
| 19.102(Abnormal Operation) |
- |
- |
|
- |
| 20.1(Stability & Mechanical Hazards, IS 302-1) |
- |
- |
|
- |
| 20.2(Stability & Mechanical Hazards, IS 302-1) |
- |
- |
|
- |
| 20.101(Stability & Mechanical Hazards) |
- |
- |
|
- |
| 20.102(Stability & Mechanical Hazards) |
- |
- |
|
- |
| 20.103(Stability & Mechanical Hazards) |
- |
- |
|
- |
| 20.104(Stability & Mechanical Hazards) |
- |
- |
|
- |
| 20.105(Stability & Mechanical Hazards) |
- |
- |
|
- |
| 20.106(Stability & Mechanical Hazards) |
- |
- |
|
- |
| 20.107(Stability & Mechanical Hazards) |
- |
- |
|
- |
| 20.108(Stability & Mechanical Hazards) |
- |
- |
|
- |
| 20.109(Stability & Mechanical Hazards) |
- |
- |
|
- |
| 20.110(Stability & Mechanical Hazards) |
- |
- |
|
- |
| 20.111(Stability & Mechanical Hazards) |
- |
- |
|
- |
| 20.112(Stability & Mechanical Hazards) |
- |
- |
|
- |
| 20.113(Stability & Mechanical Hazards) |
- |
- |
|
- |
| 20.114(Stability & Mechanical Hazards) |
- |
- |
|
- |
| 20.115(Stability & Mechanical Hazards) |
- |
- |
|
- |
| 20.116(Stability & Mechanical Hazards) |
- |
- |
|
- |
| 21.1(Mechanical Strength, IS 302-1) |
- |
- |
|
- |
| 21.2(Mechanical Strength, IS 302-1) |
- |
- |
|
- |
| 22(Construction, IS 302-1) |
- |
- |
|
- |
| 22.101(Construction) |
- |
- |
|
- |
| 22.102(Construction) |
- |
- |
|
- |
| 23.1(Internal Wiring, IS 302-1) |
- |
- |
|
- |
| 23.2(Internal Wiring, IS 302-1) |
- |
- |
|
- |
| 23.3(Internal Wiring, IS 302-1) |
- |
- |
|
- |
| 23.4(Internal Wiring, IS 302-1) |
- |
- |
|
- |
| 23.5(Internal Wiring, IS 302-1) |
- |
- |
|
- |
| 23.6(Internal Wiring, IS 302-1) |
- |
- |
|
- |
| 23.7(Internal Wiring, IS 302-1) |
- |
- |
|
- |
| 23.8(Internal Wiring, IS 302-1) |
- |
- |
|
- |
| 23.9(Internal Wiring, IS 302-1) |
- |
- |
|
- |
| 23.10(Internal Wiring, IS 302-1) |
- |
- |
|
- |
| 24.1(Components, IS 302-1) |
- |
- |
|
- |
| 24.2(Components, IS 302-1) |
- |
- |
|
- |
| 24.5(Components, IS 302-1) |
- |
- |
|
- |
| 24.6(Components, IS 302-1) |
- |
- |
|
- |
| 25.1(Supply Connection and External Flexible Cords, IS 302-1) |
- |
- |
|
- |
| 25.5(Supply Connection and External Flexible Cords, IS 302-1) |
- |
- |
|
- |
| 25.6(Supply Connection and External Flexible Cords, IS 302-1) |
- |
- |
|
- |
| 25.7(Supply Connection and External Flexible Cords, IS 302-1) |
- |
- |
|
- |
| 25.8(Supply Connection and External Flexible Cords, IS 302-1) |
- |
- |
|
- |
| 26.9(Supply Connection and External Flexible Cords, IS 302-1) |
- |
- |
|
- |
| 25.1(Supply Connection and External Flexible Cords, IS 302-1) |
- |
- |
|
- |
| 25.11(Supply Connection and External Flexible Cords, IS 302-1) |
- |
- |
|
- |
| 25.12(Supply Connection and External Flexible Cords, IS 302-1) |
- |
- |
|
- |
| 25.13(Supply Connection and External Flexible Cords, IS 302-1) |
- |
- |
|
- |
| 25.14(Supply Connection and External Flexible Cords, IS 302-1) |
- |
- |
|
- |
| 25.14(Supply Connection and External Flexible Cords, IS 302-1) |
- |
- |
|
- |
| 25.15(Supply Connection and External Flexible Cords, IS 302-1) |
- |
- |
|
- |
| 25.16(Supply Connection and External Flexible Cords, IS 302-1) |
- |
- |
|
- |
| 25.17(Supply Connection and External Flexible Cords, IS 302-1) |
- |
- |
|
- |
| 25.18(Supply Connection and External Flexible Cords, IS 302-1) |
- |
- |
|
- |
| 25.19(Supply Connection and External Flexible Cords, IS 302-1) |
- |
- |
|
- |
| 25.2(Supply Connection and External Flexible Cords, IS 302-1) |
- |
- |
|
- |
| 25.21(Supply Connection and External Flexible Cords, IS 302-1) |
- |
- |
|
- |
| 25.22(Supply Connection and External Flexible Cords, IS 302-1) |
- |
- |
|
- |
| 26(Terminals for External Conductors, IS 302-1) |
- |
- |
|
- |
| 27(Provision for Earthing, IS 302-1) |
- |
- |
|
- |
| 27.2(Provision for Earthing, IS 302-1) |
- |
- |
|
- |
| 27.3(Provision for Earthing, IS 302-1) |
- |
- |
|
- |
| 27.4(Provision for Earthing, IS 302-1) |
- |
- |
|
- |
| 27.5(Provision for Earthing, IS 302-1) |
- |
- |
|
- |
| 28(Screws & Connections, IS 302-1) |
- |
- |
|
- |
| 29.1(Clearances, Creepage distances and Solid Insulation, IS 302-1) |
- |
- |
|
- |
| 29.2(Clearances, Creepage distances and Solid Insulation, IS 302-1) |
- |
- |
|
- |
| 30.1(Resistance to Heat and Fire, IS 302-1) |
- |
- |
|
- |
| 30.2(Resistance to Heat and Fire, IS 302-1) |
- |
- |
|
- |
| 31(Resistance of Rusting, IS 302-1) |
- |
- |
|
- |
| 32(Radiation, Toxicity and similar Hazard IS 302-1) |
- |
- |
|
- |
| 19.11.4.1(Electrostatic discharges) |
- |
- |
|
- |
| 19.11.4.2(Radiated fields) |
- |
- |
|
- |
| 19.11.4.3(Fast transient bursts) |
- |
- |
|
- |
| 19.11.4.4(Surge immunity test) |
- |
- |
|
- |
| 19.11.4.5(Immunity to conducted discharges) |
- |
- |
|
- |
| 19.11.4.6(Class 3 Voltage dips and interruptions) |
- |
- |
|
- |
| 19.11.4.7(Harmonics) |
- |
- |
|
- |
| 19.11.4.5(Immunity to conducted discharges) |
- |
- |
|
- |
| 4(GENERAL REQUIREMENTS) |
- |
- |
|
- |
| 5(GENERAL CONDITIONS FOR THE TESTS) |
- |
- |
|
- |
| 27(Provision for Earthing) |
- |
- |
|
- |
| 29(Clearances, Creepage distances and Solid Insulation) |
- |
- |
|
- |
|
02 Sep, 2028 |
- Included w.e.f 07.08.2026
Exclusion:
"19.11.4.1 (Electrostatic discharges)
19.11.4.2 (Radiated fields)
19.11.4.3 (Fast transient bursts)
19.11.4.4 (Surge immunity test)
19.11.4.5 (Immunity to conducted discharges)
19.11.4.6 (Class 3 Voltage dips and interruptions)
19.11.4.7 (Harmonics)
22 (Construction, IS 302-1)
32 (Radiation, Toxicity and similar Hazard IS 302-1)
" |
| 7 |
IS 302 : Part 2 : Sec 75 (2018) |
Safety of Household and Similar Electrical Appliances Part 2 Particular Requirements Section 75 Commercial Dispensing Appliances and Vending Machines |
-- |
75000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 32(Radiation, toxicity and similar hazards) |
- |
0 |
|
N/A |
| 31(Resistance to rusting) |
- |
500 |
|
N/A |
| 30.2.4(Resistance to heat and fire) |
- |
500 |
|
N/A |
| 30.2(Resistance to heat and fire) |
- |
500 |
|
N/A |
| 30.1(Resistance to heat and fire) |
- |
500 |
|
N/A |
| 29.3(Clearances, creepage distances and solid insulation) |
- |
500 |
|
N/A |
| 29.2(Clearances, creepage distances and solid insulation) |
- |
500 |
|
N/A |
| 29.2(Clearances, creepage distances and solid insulation) |
- |
500 |
|
N/A |
| 29.1, Table No.- 16, Table No.- 17 & Table No.18(Clearances, creepage distances and solid insulation) |
- |
500 |
|
N/A |
| 29.1, Table No.- 16, Table No.- 17 & Table No.18(Clearances, creepage distances and solid insulation) |
- |
500 |
|
N/A |
| 28.2 to 28.4(Screws and connections) |
- |
500 |
|
N/A |
| 28.1, Table No.-14(Screws and connections) |
- |
500 |
|
N/A |
| 27.6(Provision for earthing) |
- |
500 |
|
N/A |
| 27.5(Provision for earthing) |
- |
500 |
|
N/A |
| 27.1 to 27.4(Provision for earthing) |
- |
500 |
|
N/A |
| 26.10 & 26.11(Terminals for external conductors) |
- |
500 |
|
N/A |
| 26.9(Terminals for external conductors) |
- |
500 |
|
N/A |
| 26.1 to 26.8(Terminals for external conductors) |
- |
500 |
|
N/A |
| 25.16 to 25.25(Supply connection and external flexible cords) |
- |
500 |
|
N/A |
| 25.15(Supply connection and external flexible cords) |
- |
500 |
|
N/A |
| 25.14(Supply connection and external flexible cords) |
- |
500 |
|
N/A |
| 25.9 to 25.13(Supply connection and external flexible cords) |
- |
500 |
|
N/A |
| 25.8, Table No.-11(Supply connection and external flexible cords) |
- |
500 |
|
N/A |
| 25.5 to 25.7(Supply connection and external flexible cords) |
- |
500 |
|
N/A |
| 25.4(Supply connection and external flexible cords) |
- |
500 |
|
N/A |
| 25.3(Supply connection and external flexible cords) |
- |
500 |
|
N/A |
| 25.2(Supply connection and external flexible cords) |
- |
500 |
|
N/A |
| 25.1(Supply connection and external flexible cords) |
- |
500 |
|
N/A |
| 24.101 to 24.103(Components) |
- |
200 |
|
N/A |
| 24.2 to 24.6(Components) |
- |
200 |
|
N/A |
| 24.1(Components) |
- |
500 |
|
N/A |
| 23.101 to 23.102(Internal wiring) |
- |
500 |
|
N/A |
| 23.6 to 23.10(Internal wiring) |
- |
100 |
|
N/A |
| 23.5(Internal wiring) |
- |
100 |
|
N/A |
| 23.4(Internal wiring) |
- |
100 |
|
N/A |
| 23.3(Internal wiring) |
- |
500 |
|
N/A |
| 23.1 & 23.2(Internal wiring) |
- |
100 |
|
N/A |
| 22.101 to 22.114(Constructions) |
- |
500 |
|
N/A |
| 22.13 to 22.48(Constructions) |
- |
500 |
|
N/A |
| 22.12(Constructions) |
- |
500 |
|
N/A |
| 22.11(Constructions) |
- |
100 |
|
N/A |
| 22.11(Constructions) |
- |
100 |
|
N/A |
| 22.7 to 22.10(Constructions) |
- |
500 |
|
N/A |
| 22.6(Constructions) |
- |
500 |
|
N/A |
| 22.5(Constructions) |
- |
100 |
|
N/A |
| 22.4(Constructions) |
- |
100 |
|
N/A |
| 22.3(Constructions) |
- |
500 |
|
N/A |
| 22.2(Constructions) |
- |
100 |
|
N/A |
| 22.1(Constructions) |
- |
500 |
|
N/A |
| 21.2(MECHANICAL STRENGTH) |
- |
100 |
|
N/A |
| 21.1(MECHANICAL STRENGTH) |
- |
500 |
|
N/A |
| 20.2(Stability and mechanical hazards) |
- |
500 |
|
N/A |
| 20.1(Stability and mechanical hazards) |
- |
500 |
|
N/A |
| 19.101 and 19.102(ABNORMAL OPERATION) |
- |
500 |
|
N/A |
| 19.1 to 19.13, Table No. - 9(ABNORMAL OPERATION) |
- |
500 |
|
N/A |
| 17(Overload protection of transformers and associated circuits) |
- |
200 |
|
N/A |
| 16.3(Insulation resistance test) |
- |
100 |
|
N/A |
| 16.3(Electric strength test) |
- |
500 |
|
N/A |
| 16.1 & 16.2(Leakage current test) |
- |
200 |
|
N/A |
| 15.102(Moisture resistance) |
- |
500 |
|
N/A |
| 15.102(Moisture resistance) |
- |
200 |
|
N/A |
| 15.101(Moisture resistance) |
- |
200 |
|
N/A |
| 15.3(Moisture resistance) |
- |
500 |
|
N/A |
| 15.2(Moisture resistance) |
- |
500 |
|
N/A |
| 15.1(Moisture resistance) |
- |
500 |
|
N/A |
| 14, Table No.- 6 & Table No.-16(Transient over voltages) |
- |
200 |
|
N/A |
| 13.3 and Table No.- 4(Electric strength test) |
- |
500 |
|
N/A |
| 13.1, 13.2(Leakage current test) |
- |
500 |
|
N/A |
| 11.1 to 11.8, Table No.-3(Heating) |
- |
100 |
|
N/A |
| 10.1 & 10.2 -Table No. 1, Table No. 2(Power Input and Current) |
- |
100 |
|
N/A |
| 8.1.5(Protection against access to live parts) |
- |
500 |
|
N/A |
| 8.1.4(Protection against access to live parts) |
- |
500 |
|
N/A |
| 8.1.3(Protection against access to live parts) |
- |
500 |
|
N/A |
| 8.1.2(Protection against access to live parts) |
- |
500 |
|
N/A |
| 8.1, 8.1.1 & 8.2(Protection against access to live parts) |
- |
500 |
|
N/A |
| 7.14(Legibility & Durability of Markings test) |
- |
500 |
|
N/A |
| 7.1 to 7.13, 7.15, 7.16(Marking) |
- |
100 |
|
N/A |
| 32(Radiation, toxicity and similar hazards) |
- |
0 |
|
N/A |
| 31(Resistance to rusting) |
- |
500 |
|
N/A |
| 30.2.4(Resistance to heat and fire) |
- |
100 |
|
N/A |
| 30.2(Resistance to heat and fire) |
- |
500 |
|
N/A |
| 30.1(Resistance to heat and fire) |
- |
100 |
|
N/A |
| 29.3(Clearances, creepage distances and solid insulation) |
- |
100 |
|
N/A |
| 29.2(Clearances, creepage distances and solid insulation) |
- |
500 |
|
N/A |
| 29.2(Clearances, creepage distances and solid insulation) |
- |
100 |
|
N/A |
| 29.1, Table No.- 16, Table No.- 17 & Table No.18(Clearances, creepage distances and solid insulation) |
- |
100 |
|
N/A |
| 29.1, Table No.- 16, Table No.- 17 & Table No.18(Clearances, creepage distances and solid insulation) |
- |
500 |
|
N/A |
| 28.2 to 28.4(Screws and connections) |
- |
500 |
|
N/A |
| 28.1, Table No.-14(Screws and connections) |
- |
500 |
|
N/A |
| 27.6(Provision for earthing) |
- |
500 |
|
N/A |
| 27.5(Provision for earthing) |
- |
500 |
|
N/A |
| 27.1 to 27.4(Provision for earthing) |
- |
500 |
|
N/A |
| 26.10 & 26.11(Terminals for external conductors) |
- |
500 |
|
N/A |
| 26.9(Terminals for external conductors) |
- |
500 |
|
N/A |
| 26.1 to 26.8(Terminals for external conductors) |
- |
500 |
|
N/A |
| 25.16 to 25.25(Supply connection and external flexible cords) |
- |
500 |
|
N/A |
| 25.15(Supply connection and external flexible cords) |
- |
500 |
|
N/A |
| 25.14(Supply connection and external flexible cords) |
- |
500 |
|
N/A |
| 25.9 to 25.13(Supply connection and external flexible cords) |
- |
500 |
|
N/A |
| 25.8, Table No.-11(Supply connection and external flexible cords) |
- |
500 |
|
N/A |
| 25.5 to 25.7(Supply connection and external flexible cords) |
- |
500 |
|
N/A |
| 25.4(Supply connection and external flexible cords) |
- |
500 |
|
N/A |
| 25.3(Supply connection and external flexible cords) |
- |
500 |
|
N/A |
| 25.2(Supply connection and external flexible cords) |
- |
500 |
|
N/A |
| 25.1(Supply connection and external flexible cords) |
- |
500 |
|
N/A |
| 24.101 to 24.103(Components) |
- |
500 |
|
N/A |
| 24.2 to 24.6(Components) |
- |
500 |
|
N/A |
| 24.1(Components) |
- |
500 |
|
N/A |
| 23.101 to 23.102(Internal wiring) |
- |
500 |
|
N/A |
| 23.6 to 23.10(Internal wiring) |
- |
600 |
|
N/A |
| 23.5(Internal wiring) |
- |
500 |
|
N/A |
| 23.4(Internal wiring) |
- |
1000 |
|
N/A |
| 23.3(Internal wiring) |
- |
200 |
|
N/A |
| 23.1 & 23.2(Internal wiring) |
- |
1000 |
|
N/A |
| 22.101 to 22.114(Constructions) |
- |
1000 |
|
N/A |
| 22.13 to 22.48(Constructions) |
- |
300 |
|
N/A |
| 22.12(Constructions) |
- |
1000 |
|
N/A |
| 22.11(Constructions) |
- |
400 |
|
N/A |
| 22.11(Constructions) |
- |
1000 |
|
N/A |
| 22.7 to 22.10(Constructions) |
- |
1000 |
|
N/A |
| 22.6(Constructions) |
- |
1000 |
|
N/A |
| 22.5(Constructions) |
- |
1000 |
|
N/A |
| 22.4(Constructions) |
- |
300 |
|
N/A |
| 22.3(Constructions) |
- |
1000 |
|
N/A |
| 22.2(Constructions) |
- |
300 |
|
N/A |
| 22.1(Constructions) |
- |
300 |
|
N/A |
| 21.2(MECHANICAL STRENGTH) |
- |
500 |
|
N/A |
| 21.1(MECHANICAL STRENGTH) |
- |
1000 |
|
N/A |
| 20.2(Stability and mechanical hazards) |
- |
500 |
|
N/A |
| 20.1(Stability and mechanical hazards) |
- |
1000 |
|
N/A |
| 19.101 and 19.102(ABNORMAL OPERATION) |
- |
1000 |
|
N/A |
| 19.1 to 19.13, Table No. - 9(ABNORMAL OPERATION) |
- |
1000 |
|
N/A |
| 17(Overload protection of transformers and associated circuits) |
- |
300 |
|
N/A |
| 16.3(Insulation resistance test) |
- |
1000 |
|
N/A |
| 16.3(Electric strength test) |
- |
1000 |
|
N/A |
| 16.1 & 16.2(Leakage current test) |
- |
1000 |
|
N/A |
| 15.102(Moisture resistance) |
- |
1000 |
|
N/A |
| 15.102(Moisture resistance) |
- |
1000 |
|
N/A |
| 15.101(Moisture resistance) |
- |
1000 |
|
N/A |
| 15.3(Moisture resistance) |
- |
1000 |
|
N/A |
| 15.2(Moisture resistance) |
- |
200 |
|
N/A |
| 15.1(Moisture resistance) |
- |
1000 |
|
N/A |
| 14, Table No.- 6 & Table No.-16(Transient over voltages) |
- |
1000 |
|
N/A |
| 13.3 and Table No.- 4(Electric strength test) |
- |
500 |
|
N/A |
| 13.1, 13.2(Leakage current test) |
- |
500 |
|
N/A |
| 11.1 to 11.8, Table No.-3(Heating) |
- |
500 |
|
N/A |
| 10.1 & 10.2 -Table No. 1, Table No. 2(Power Input and Current) |
- |
500 |
|
N/A |
| 8.1.5(Protection against access to live parts) |
- |
500 |
|
N/A |
| 8.1.4(Protection against access to live parts) |
- |
500 |
|
N/A |
| 8.1.3(Protection against access to live parts) |
- |
200 |
|
N/A |
| 8.1.2(Protection against access to live parts) |
- |
500 |
|
N/A |
| 8.1, 8.1.1 & 8.2(Protection against access to live parts) |
- |
300 |
|
N/A |
| 7.14(Legibility & Durability of Markings test) |
- |
500 |
|
N/A |
| 7.1 to 7.13, 7.15, 7.16(Marking) |
- |
400 |
|
N/A |
| 19.11.4.1(Electrostatic discharges) |
- |
0 |
|
N/A |
| 19.11.4.2(Radiated fields) |
- |
0 |
|
N/A |
| 19.11.4.3(Fast transient bursts) |
- |
0 |
|
N/A |
| 19.11.4.4(Surge immunity test) |
- |
0 |
|
N/A |
| 19.11.4.5(Immunity to conducted discharges) |
- |
0 |
|
N/A |
| 19.11.4.6(Class 3 Voltage dips and interruptions) |
- |
0 |
|
N/A |
| 19.11.4.7(Harmonics) |
- |
0 |
|
N/A |
| 32(Radiation, toxicity and similar hazards) |
- |
0 |
|
N/A |
| 31(Resistance to rusting) |
- |
0 |
|
N/A |
| 30.2.4(Resistance to heat and fire) |
- |
0 |
|
N/A |
| 30.2(Resistance to heat and fire) |
- |
0 |
|
N/A |
| 30.1(Resistance to heat and fire) |
- |
0 |
|
N/A |
| 29.3(Clearances, creepage distances and solid insulation) |
- |
0 |
|
N/A |
| 29.2(Clearances, creepage distances and solid insulation) |
- |
0 |
|
N/A |
| 29.2(Clearances, creepage distances and solid insulation) |
- |
0 |
|
N/A |
| 29.1, Table No.- 16, Table No.- 17 & Table No.18(Clearances, creepage distances and solid insulation) |
- |
0 |
|
N/A |
| 29.1, Table No.- 16, Table No.- 17 & Table No.18(Clearances, creepage distances and solid insulation) |
- |
0 |
|
N/A |
| 28.2 to 28.4(Screws and connections) |
- |
0 |
|
N/A |
| 28.1, Table No.-14(Screws and connections) |
- |
0 |
|
N/A |
| 27.6(Provision for earthing) |
- |
0 |
|
N/A |
| 27.5(Provision for earthing) |
- |
0 |
|
N/A |
| 27.1 to 27.4(Provision for earthing) |
- |
0 |
|
N/A |
| 26.10 & 26.11(Terminals for external conductors) |
- |
0 |
|
N/A |
| 26.9(Terminals for external conductors) |
- |
0 |
|
N/A |
| 26.1 to 26.8(Terminals for external conductors) |
- |
0 |
|
N/A |
| 25.16 to 25.25(Supply connection and external flexible cords) |
- |
0 |
|
N/A |
| 25.15(Supply connection and external flexible cords) |
- |
0 |
|
N/A |
| 25.14(Supply connection and external flexible cords) |
- |
0 |
|
N/A |
| 25.9 to 25.13(Supply connection and external flexible cords) |
- |
0 |
|
N/A |
| 25.8, Table No.-11(Supply connection and external flexible cords) |
- |
0 |
|
N/A |
| 25.5 to 25.7(Supply connection and external flexible cords) |
- |
0 |
|
N/A |
| 25.4(Supply connection and external flexible cords) |
- |
0 |
|
N/A |
| 25.3(Supply connection and external flexible cords) |
- |
0 |
|
N/A |
| 25.2(Supply connection and external flexible cords) |
- |
0 |
|
N/A |
| 25.1(Supply connection and external flexible cords) |
- |
0 |
|
N/A |
| 24.101 to 24.103(Components) |
- |
0 |
|
N/A |
| 24.2 to 24.6(Components) |
- |
0 |
|
N/A |
| 24.1(Components) |
- |
0 |
|
N/A |
| 23.101 to 23.102(Internal wiring) |
- |
0 |
|
N/A |
| 23.6 to 23.10(Internal wiring) |
- |
0 |
|
N/A |
| 23.5(Internal wiring) |
- |
0 |
|
N/A |
| 23.4(Internal wiring) |
- |
0 |
|
N/A |
| 23.3(Internal wiring) |
- |
0 |
|
N/A |
| 23.1 & 23.2(Internal wiring) |
- |
0 |
|
N/A |
| 22.101 to 22.114(Constructions) |
- |
0 |
|
N/A |
| 22.13 to 22.48(Constructions) |
- |
0 |
|
N/A |
| 22.12(Constructions) |
- |
0 |
|
N/A |
| 22.11(Constructions) |
- |
0 |
|
N/A |
| 22.11(Constructions) |
- |
0 |
|
N/A |
| 22.7 to 22.10(Constructions) |
- |
0 |
|
N/A |
| 22.6(Constructions) |
- |
0 |
|
N/A |
| 22.5(Constructions) |
- |
0 |
|
N/A |
| 22.4(Constructions) |
- |
0 |
|
N/A |
| 22.3(Constructions) |
- |
0 |
|
N/A |
| 22.2(Constructions) |
- |
0 |
|
N/A |
| 22.1(Constructions) |
- |
0 |
|
N/A |
| 21.2(MECHANICAL STRENGTH) |
- |
0 |
|
N/A |
| 21.1(MECHANICAL STRENGTH) |
- |
0 |
|
N/A |
| 20.2(Stability and mechanical hazards) |
- |
0 |
|
N/A |
| 20.1(Stability and mechanical hazards) |
- |
0 |
|
N/A |
| 19.101 and 19.102(ABNORMAL OPERATION) |
- |
0 |
|
N/A |
| 19.1 to 19.13, Table No. - 9(ABNORMAL OPERATION) |
- |
0 |
|
N/A |
| 17(Overload protection of transformers and associated circuits) |
- |
0 |
|
N/A |
| 16.3(Insulation resistance test) |
- |
0 |
|
N/A |
| 16.3(Electric strength test) |
- |
0 |
|
N/A |
| 16.1 & 16.2(Leakage current test) |
- |
0 |
|
N/A |
| 15.102(Moisture resistance) |
- |
0 |
|
N/A |
| 15.102(Moisture resistance) |
- |
0 |
|
N/A |
| 15.101(Moisture resistance) |
- |
0 |
|
N/A |
| 15.3(Moisture resistance) |
- |
0 |
|
N/A |
| 15.2(Moisture resistance) |
- |
0 |
|
N/A |
| 15.1(Moisture resistance) |
- |
0 |
|
N/A |
| 14, Table No.- 6 & Table No.-16(Transient over voltages) |
- |
0 |
|
N/A |
| 13.3 and Table No.- 4(Electric strength test) |
- |
0 |
|
N/A |
| 13.1, 13.2(Leakage current test) |
- |
0 |
|
N/A |
| 11.1 to 11.8, Table No.-3(Heating) |
- |
0 |
|
N/A |
| 10.1 & 10.2 -Table No. 1, Table No. 2(Power Input and Current) |
- |
0 |
|
N/A |
| 8.1.5(Protection against access to live parts) |
- |
0 |
|
N/A |
| 8.1.4(Protection against access to live parts) |
- |
0 |
|
N/A |
| 8.1.3(Protection against access to live parts) |
- |
0 |
|
N/A |
| 8.1.2(Protection against access to live parts) |
- |
0 |
|
N/A |
| 8.1, 8.1.1 & 8.2(Protection against access to live parts) |
- |
0 |
|
N/A |
| 7.14(Legibility & Durability of Markings test) |
- |
0 |
|
N/A |
| 7.1 to 7.13, 7.15, 7.16(Marking) |
- |
0 |
|
N/A |
| 32(Radiation, toxicity and similar hazards) |
- |
0 |
|
N/A |
| 31(Resistance to rusting) |
- |
0 |
|
N/A |
| 30.2.4(Resistance to heat and fire) |
- |
0 |
|
N/A |
| 30.2(Resistance to heat and fire) |
- |
0 |
|
N/A |
| 30.1(Resistance to heat and fire) |
- |
0 |
|
N/A |
| 29.3(Clearances, creepage distances and solid insulation) |
- |
0 |
|
N/A |
| 29.2(Clearances, creepage distances and solid insulation) |
- |
0 |
|
N/A |
| 29.2(Clearances, creepage distances and solid insulation) |
- |
0 |
|
N/A |
| 29.1, Table No.- 16, Table No.- 17 & Table No.18(Clearances, creepage distances and solid insulation) |
- |
0 |
|
N/A |
| 29.1, Table No.- 16, Table No.- 17 & Table No.18(Clearances, creepage distances and solid insulation) |
- |
0 |
|
N/A |
| 28.2 to 28.4(Screws and connections) |
- |
0 |
|
N/A |
| 28.1, Table No.-14(Screws and connections) |
- |
0 |
|
N/A |
| 27.6(Provision for earthing) |
- |
0 |
|
N/A |
| 27.5(Provision for earthing) |
- |
0 |
|
N/A |
| 27.1 to 27.4(Provision for earthing) |
- |
0 |
|
N/A |
| 26.10 & 26.11(Terminals for external conductors) |
- |
0 |
|
N/A |
| 26.9(Terminals for external conductors) |
- |
0 |
|
N/A |
| 26.1 to 26.8(Terminals for external conductors) |
- |
0 |
|
N/A |
| 25.16 to 25.25(Supply connection and external flexible cords) |
- |
0 |
|
N/A |
| 25.15(Supply connection and external flexible cords) |
- |
0 |
|
N/A |
| 25.14(Supply connection and external flexible cords) |
- |
0 |
|
N/A |
| 25.9 to 25.13(Supply connection and external flexible cords) |
- |
0 |
|
N/A |
| 25.8, Table No.-11(Supply connection and external flexible cords) |
- |
0 |
|
N/A |
| 25.5 to 25.7(Supply connection and external flexible cords) |
- |
0 |
|
N/A |
| 25.4(Supply connection and external flexible cords) |
- |
0 |
|
N/A |
| 25.3(Supply connection and external flexible cords) |
- |
0 |
|
N/A |
| 25.2(Supply connection and external flexible cords) |
- |
0 |
|
N/A |
| 25.1(Supply connection and external flexible cords) |
- |
0 |
|
N/A |
| 24.101 to 24.103(Components) |
- |
0 |
|
N/A |
| 24.2 to 24.6(Components) |
- |
0 |
|
N/A |
| 24.1(Components) |
- |
0 |
|
N/A |
| 23.101 to 23.102(Internal wiring) |
- |
0 |
|
N/A |
| 23.6 to 23.10(Internal wiring) |
- |
0 |
|
N/A |
| 23.5(Internal wiring) |
- |
0 |
|
N/A |
| 23.4(Internal wiring) |
- |
0 |
|
N/A |
| 23.3(Internal wiring) |
- |
0 |
|
N/A |
| 23.1 & 23.2(Internal wiring) |
- |
0 |
|
N/A |
| 22.101 to 22.114(Constructions) |
- |
0 |
|
N/A |
| 22.13 to 22.48(Constructions) |
- |
0 |
|
N/A |
| 22.12(Constructions) |
- |
0 |
|
N/A |
| 22.11(Constructions) |
- |
0 |
|
N/A |
| 22.11(Constructions) |
- |
0 |
|
N/A |
| 22.7 to 22.10(Constructions) |
- |
0 |
|
N/A |
| 22.6(Constructions) |
- |
0 |
|
N/A |
| 22.5(Constructions) |
- |
0 |
|
N/A |
| 22.4(Constructions) |
- |
0 |
|
N/A |
| 22.3(Constructions) |
- |
0 |
|
N/A |
| 22.2(Constructions) |
- |
0 |
|
N/A |
| 22.1(Constructions) |
- |
0 |
|
N/A |
| 21.2(MECHANICAL STRENGTH) |
- |
0 |
|
N/A |
| 21.1(MECHANICAL STRENGTH) |
- |
0 |
|
N/A |
| 20.2(Stability and mechanical hazards) |
- |
0 |
|
N/A |
| 20.1(Stability and mechanical hazards) |
- |
0 |
|
N/A |
| 19.101 and 19.102(ABNORMAL OPERATION) |
- |
0 |
|
N/A |
| 19.1 to 19.13, Table No. - 9(ABNORMAL OPERATION) |
- |
0 |
|
N/A |
| 17(Overload protection of transformers and associated circuits) |
- |
0 |
|
N/A |
| 16.3(Insulation resistance test) |
- |
0 |
|
N/A |
| 16.3(Electric strength test) |
- |
0 |
|
N/A |
| 16.1 & 16.2(Leakage current test) |
- |
0 |
|
N/A |
| 15.102(Moisture resistance) |
- |
0 |
|
N/A |
| 15.102(Moisture resistance) |
- |
0 |
|
N/A |
| 15.101(Moisture resistance) |
- |
0 |
|
N/A |
| 15.3(Moisture resistance) |
- |
0 |
|
N/A |
| 15.2(Moisture resistance) |
- |
0 |
|
N/A |
| 15.1(Moisture resistance) |
- |
0 |
|
N/A |
| 14, Table No.- 6 & Table No.-16(Transient over voltages) |
- |
0 |
|
N/A |
| 13.3 and Table No.- 4(Electric strength test) |
- |
0 |
|
N/A |
| 13.1, 13.2(Leakage current test) |
- |
0 |
|
N/A |
| 11.1 to 11.8, Table No.-3(Heating) |
- |
0 |
|
N/A |
| 10.1 & 10.2 -Table No. 1, Table No. 2(Power Input and Current) |
- |
0 |
|
N/A |
| 8.1.5(Protection against access to live parts) |
- |
0 |
|
N/A |
| 8.1.4(Protection against access to live parts) |
- |
0 |
|
N/A |
| 8.1.3(Protection against access to live parts) |
- |
0 |
|
N/A |
| 8.1.2(Protection against access to live parts) |
- |
0 |
|
N/A |
| 8.1, 8.1.1 & 8.2(Protection against access to live parts) |
- |
0 |
|
N/A |
| 7.14(Legibility & Durability of Markings test) |
- |
0 |
|
N/A |
| 7.1 to 7.13, 7.15, 7.16(Marking) |
- |
0 |
|
N/A |
| 19.11.4.1(Electrostatic discharges) |
- |
0 |
|
N/A |
| 19.11.4.2(Radiated fields) |
- |
0 |
|
N/A |
| 19.11.4.3(Fast transient bursts) |
- |
0 |
|
N/A |
| 19.11.4.4(Surge immunity test) |
- |
0 |
|
N/A |
| 19.11.4.5(Immunity to conducted discharges) |
- |
0 |
|
N/A |
| 19.11.4.6(Class 3 Voltage dips and interruptions) |
- |
0 |
|
N/A |
| 19.11.4.7(Harmonics) |
- |
0 |
|
N/A |
| 32(Radiation, toxicity and similar hazards) |
- |
0 |
|
N/A |
| 31(Resistance to rusting) |
- |
0 |
|
N/A |
| 30.2.4(Resistance to heat and fire) |
- |
0 |
|
N/A |
| 30.2(Resistance to heat and fire) |
- |
0 |
|
N/A |
| 30.1(Resistance to heat and fire) |
- |
0 |
|
N/A |
| 29.3(Clearances, creepage distances and solid insulation) |
- |
0 |
|
N/A |
| 29.2(Clearances, creepage distances and solid insulation) |
- |
0 |
|
N/A |
| 29.2(Clearances, creepage distances and solid insulation) |
- |
0 |
|
N/A |
| 29.1, Table No.- 16, Table No.- 17 & Table No.18(Clearances, creepage distances and solid insulation) |
- |
0 |
|
N/A |
| 29.1, Table No.- 16, Table No.- 17 & Table No.18(Clearances, creepage distances and solid insulation) |
- |
0 |
|
N/A |
| 28.2 to 28.4(Screws and connections) |
- |
0 |
|
N/A |
| 28.1, Table No.-14(Screws and connections) |
- |
0 |
|
N/A |
| 27.6(Provision for earthing) |
- |
0 |
|
N/A |
| 27.5(Provision for earthing) |
- |
0 |
|
N/A |
| 27.1 to 27.4(Provision for earthing) |
- |
0 |
|
N/A |
| 26.10 & 26.11(Terminals for external conductors) |
- |
0 |
|
N/A |
| 26.9(Terminals for external conductors) |
- |
0 |
|
N/A |
| 26.1 to 26.8(Terminals for external conductors) |
- |
0 |
|
N/A |
| 25.16 to 25.25(Supply connection and external flexible cords) |
- |
0 |
|
N/A |
| 25.15(Supply connection and external flexible cords) |
- |
0 |
|
N/A |
| 25.14(Supply connection and external flexible cords) |
- |
0 |
|
N/A |
| 25.9 to 25.13(Supply connection and external flexible cords) |
- |
0 |
|
N/A |
| 25.8, Table No.-11(Supply connection and external flexible cords) |
- |
0 |
|
N/A |
| 25.5 to 25.7(Supply connection and external flexible cords) |
- |
0 |
|
N/A |
| 25.4(Supply connection and external flexible cords) |
- |
0 |
|
N/A |
| 25.3(Supply connection and external flexible cords) |
- |
0 |
|
N/A |
| 25.2(Supply connection and external flexible cords) |
- |
0 |
|
N/A |
| 25.1(Supply connection and external flexible cords) |
- |
0 |
|
N/A |
| 24.101 to 24.103(Components) |
- |
0 |
|
N/A |
| 24.2 to 24.6(Components) |
- |
0 |
|
N/A |
| 24.1(Components) |
- |
0 |
|
N/A |
| 23.101 to 23.102(Internal wiring) |
- |
0 |
|
N/A |
| 23.6 to 23.10(Internal wiring) |
- |
0 |
|
N/A |
| 23.5(Internal wiring) |
- |
0 |
|
N/A |
| 23.4(Internal wiring) |
- |
0 |
|
N/A |
| 23.3(Internal wiring) |
- |
0 |
|
N/A |
| 23.1 & 23.2(Internal wiring) |
- |
0 |
|
N/A |
| 22.101 to 22.114(Constructions) |
- |
0 |
|
N/A |
| 22.13 to 22.48(Constructions) |
- |
0 |
|
N/A |
| 22.12(Constructions) |
- |
0 |
|
N/A |
| 22.11(Constructions) |
- |
0 |
|
N/A |
| 22.11(Constructions) |
- |
0 |
|
N/A |
| 22.7 to 22.10(Constructions) |
- |
0 |
|
N/A |
| 22.6(Constructions) |
- |
0 |
|
N/A |
| 22.5(Constructions) |
- |
0 |
|
N/A |
| 22.4(Constructions) |
- |
0 |
|
N/A |
| 22.3(Constructions) |
- |
0 |
|
N/A |
| 22.2(Constructions) |
- |
0 |
|
N/A |
| 22.1(Constructions) |
- |
0 |
|
N/A |
| 21.2(MECHANICAL STRENGTH) |
- |
0 |
|
N/A |
| 21.1(MECHANICAL STRENGTH) |
- |
0 |
|
N/A |
| 20.2(Stability and mechanical hazards) |
- |
0 |
|
N/A |
| 20.1(Stability and mechanical hazards) |
- |
0 |
|
N/A |
| 19.101 and 19.102(ABNORMAL OPERATION) |
- |
0 |
|
N/A |
| 19.1 to 19.13, Table No. - 9(ABNORMAL OPERATION) |
- |
0 |
|
N/A |
| 17(Overload protection of transformers and associated circuits) |
- |
0 |
|
N/A |
| 16.3(Insulation resistance test) |
- |
0 |
|
N/A |
| 16.3(Electric strength test) |
- |
0 |
|
N/A |
| 16.1 & 16.2(Leakage current test) |
- |
0 |
|
N/A |
| 15.102(Moisture resistance) |
- |
0 |
|
N/A |
| 15.102(Moisture resistance) |
- |
0 |
|
N/A |
| 15.101(Moisture resistance) |
- |
0 |
|
N/A |
| 15.3(Moisture resistance) |
- |
0 |
|
N/A |
| 15.2(Moisture resistance) |
- |
0 |
|
N/A |
| 15.1(Moisture resistance) |
- |
0 |
|
N/A |
| 14, Table No.- 6 & Table No.-16(Transient over voltages) |
- |
0 |
|
N/A |
| 13.3 and Table No.- 4(Electric strength test) |
- |
0 |
|
N/A |
| 13.1, 13.2(Leakage current test) |
- |
0 |
|
N/A |
| 11.1 to 11.8, Table No.-3(Heating) |
- |
0 |
|
N/A |
| 10.1 & 10.2 -Table No. 1, Table No. 2(Power Input and Current) |
- |
0 |
|
N/A |
| 8.1.5(Protection against access to live parts) |
- |
0 |
|
N/A |
| 8.1.4(Protection against access to live parts) |
- |
0 |
|
N/A |
| 8.1.3(Protection against access to live parts) |
- |
0 |
|
N/A |
| 8.1.2(Protection against access to live parts) |
- |
0 |
|
N/A |
| 8.1, 8.1.1 & 8.2(Protection against access to live parts) |
- |
0 |
|
N/A |
| 7.14(Legibility & Durability of Markings test) |
- |
0 |
|
N/A |
| 7.1 to 7.13, 7.15, 7.16(Marking) |
- |
0 |
|
N/A |
| 32(Radiation, toxicity and similar hazards) |
- |
0 |
|
N/A |
| 31(Resistance to rusting) |
- |
0 |
|
N/A |
| 30.2.4(Resistance to heat and fire) |
- |
0 |
|
N/A |
| 30.2(Resistance to heat and fire) |
- |
0 |
|
N/A |
| 30.1(Resistance to heat and fire) |
- |
0 |
|
N/A |
| 29.3(Clearances, creepage distances and solid insulation) |
- |
0 |
|
N/A |
| 29.2(Clearances, creepage distances and solid insulation) |
- |
0 |
|
N/A |
| 29.2(Clearances, creepage distances and solid insulation) |
- |
0 |
|
N/A |
| 29.1, Table No.- 16, Table No.- 17 & Table No.18(Clearances, creepage distances and solid insulation) |
- |
0 |
|
N/A |
| 29.1, Table No.- 16, Table No.- 17 & Table No.18(Clearances, creepage distances and solid insulation) |
- |
0 |
|
N/A |
| 28.2 to 28.4(Screws and connections) |
- |
0 |
|
N/A |
| 28.1, Table No.-14(Screws and connections) |
- |
0 |
|
N/A |
| 27.6(Provision for earthing) |
- |
0 |
|
N/A |
| 27.5(Provision for earthing) |
- |
0 |
|
N/A |
| 27.1 to 27.4(Provision for earthing) |
- |
0 |
|
N/A |
| 26.10 & 26.11(Terminals for external conductors) |
- |
0 |
|
N/A |
| 26.9(Terminals for external conductors) |
- |
0 |
|
N/A |
| 26.1 to 26.8(Terminals for external conductors) |
- |
0 |
|
N/A |
| 25.16 to 25.25(Supply connection and external flexible cords) |
- |
0 |
|
N/A |
| 25.15(Supply connection and external flexible cords) |
- |
0 |
|
N/A |
| 25.14(Supply connection and external flexible cords) |
- |
0 |
|
N/A |
| 25.9 to 25.13(Supply connection and external flexible cords) |
- |
0 |
|
N/A |
| 25.8, Table No.-11(Supply connection and external flexible cords) |
- |
0 |
|
N/A |
| 25.5 to 25.7(Supply connection and external flexible cords) |
- |
0 |
|
N/A |
| 25.4(Supply connection and external flexible cords) |
- |
0 |
|
N/A |
| 25.3(Supply connection and external flexible cords) |
- |
0 |
|
N/A |
| 25.2(Supply connection and external flexible cords) |
- |
0 |
|
N/A |
| 25.1(Supply connection and external flexible cords) |
- |
0 |
|
N/A |
| 24.101 to 24.103(Components) |
- |
0 |
|
N/A |
| 24.2 to 24.6(Components) |
- |
0 |
|
N/A |
| 24.1(Components) |
- |
0 |
|
N/A |
| 23.101 to 23.102(Internal wiring) |
- |
0 |
|
N/A |
| 23.6 to 23.10(Internal wiring) |
- |
0 |
|
N/A |
| 23.5(Internal wiring) |
- |
0 |
|
N/A |
| 23.4(Internal wiring) |
- |
0 |
|
N/A |
| 23.3(Internal wiring) |
- |
0 |
|
N/A |
| 23.1 & 23.2(Internal wiring) |
- |
0 |
|
N/A |
| 22.101 to 22.114(Constructions) |
- |
0 |
|
N/A |
| 22.13 to 22.48(Constructions) |
- |
0 |
|
N/A |
| 22.12(Constructions) |
- |
0 |
|
N/A |
| 22.11(Constructions) |
- |
0 |
|
N/A |
| 22.11(Constructions) |
- |
0 |
|
N/A |
| 22.7 to 22.10(Constructions) |
- |
0 |
|
N/A |
| 22.6(Constructions) |
- |
0 |
|
N/A |
| 22.5(Constructions) |
- |
0 |
|
N/A |
| 22.4(Constructions) |
- |
0 |
|
N/A |
| 22.3(Constructions) |
- |
0 |
|
N/A |
| 22.2(Constructions) |
- |
0 |
|
N/A |
| 22.1(Constructions) |
- |
0 |
|
N/A |
| 21.2(MECHANICAL STRENGTH) |
- |
0 |
|
N/A |
| 21.1(MECHANICAL STRENGTH) |
- |
0 |
|
N/A |
| 20.2(Stability and mechanical hazards) |
- |
0 |
|
N/A |
| 20.1(Stability and mechanical hazards) |
- |
0 |
|
N/A |
| 19.101 and 19.102(ABNORMAL OPERATION) |
- |
0 |
|
N/A |
| 19.1 to 19.13, Table No. - 9(ABNORMAL OPERATION) |
- |
0 |
|
N/A |
| 17(Overload protection of transformers and associated circuits) |
- |
0 |
|
N/A |
| 16.3(Insulation resistance test) |
- |
0 |
|
N/A |
| 16.3(Electric strength test) |
- |
0 |
|
N/A |
| 16.1 & 16.2(Leakage current test) |
- |
0 |
|
N/A |
| 15.102(Moisture resistance) |
- |
0 |
|
N/A |
| 15.102(Moisture resistance) |
- |
0 |
|
N/A |
| 15.101(Moisture resistance) |
- |
0 |
|
N/A |
| 15.3(Moisture resistance) |
- |
0 |
|
N/A |
| 15.2(Moisture resistance) |
- |
0 |
|
N/A |
| 15.1(Moisture resistance) |
- |
0 |
|
N/A |
| 14, Table No.- 6 & Table No.-16(Transient over voltages) |
- |
0 |
|
N/A |
| 13.3 and Table No.- 4(Electric strength test) |
- |
0 |
|
N/A |
| 13.1, 13.2(Leakage current test) |
- |
0 |
|
N/A |
| 11.1 to 11.8, Table No.-3(Heating) |
- |
0 |
|
N/A |
| 10.1 & 10.2 -Table No. 1, Table No. 2(Power Input and Current) |
- |
0 |
|
N/A |
| 8.1.5(Protection against access to live parts) |
- |
0 |
|
N/A |
| 8.1.4(Protection against access to live parts) |
- |
0 |
|
N/A |
| 8.1.3(Protection against access to live parts) |
- |
0 |
|
N/A |
| 8.1.2(Protection against access to live parts) |
- |
0 |
|
N/A |
| 8.1, 8.1.1 & 8.2(Protection against access to live parts) |
- |
0 |
|
N/A |
| 7.14(Legibility & Durability of Markings test) |
- |
0 |
|
N/A |
| 7.1 to 7.13, 7.15, 7.16(Marking) |
- |
0 |
|
N/A |
| 19.11.4.1(Electrostatic discharges) |
- |
0 |
|
N/A |
| 19.11.4.2(Radiated fields) |
- |
0 |
|
N/A |
| 19.11.4.3(Fast transient bursts) |
- |
0 |
|
N/A |
| 19.11.4.4(Surge immunity test) |
- |
0 |
|
N/A |
| 19.11.4.5(Immunity to conducted discharges) |
- |
0 |
|
N/A |
| 19.11.4.6(Class 3 Voltage dips and interruptions) |
- |
0 |
|
N/A |
| 19.11.4.7(Harmonics) |
- |
0 |
|
N/A |
|
02 Sep, 2028 |
- 1 32 (Radiation, toxicity and similar hazards) Radiation, toxicity and similar hazards Test facility not available.
2 24.1 (Components) Components Verification based on IS/IEC test report or certificates of components.
3 24.2 to 24.6 (Components) Components Verification based on IS/IEC test report or certificates of components.
4 19.11.4.1 (Electrostatic discharges) Electrostatic discharges As per IEC 61000-4-2.
5 19.11.4.2 (Radiated fields) Radiated fields As per IEC 61000-4-3.
6 19.11.4.3 (Fast transient bursts) Fast transient bursts As per IEC 61000-4-4.
7 19.11.4.4 (Surge immunity test) Surge immunity test As per IEC 61000-4-5.
8 19.11.4.5 (Immunity to conducted discharges) Immunity to conducted discharges As per IEC 61000-4-6.
9 19.11.4.6 (Class 3 Voltage dips and interruptions) Class 3 Voltage dips and interruptions As per IEC 61000-4-11.
10 19.11.4.7 (Harmonics) Harmonics As per IEC 61000-4-13.
11 22.13 to 22.48 (Constructions) Cl. 22.32 (Ageing test on rubber ) Oxygen Bomb Test facility Not available. |
| 8 |
IS 18112 (2025) |
DIGITAL TELEVISION RECEIVER FOR SATELLITE BROADCAST TRANSMISSION SPECIFICATION (First Revision) |
-- |
120000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Clause 4.4, Table-2, ii)(RF characteristics to be supported by the DTV receiver) |
- |
4000 |
|
N/A |
| Clause 4.3(Specifications) |
- |
4000 |
|
N/A |
| Clause 4.5(Safety Requirements) |
- |
3000 |
|
N/A |
| Clause 4.6(Electromagnetic Compatibility (EMC) Requirements) |
- |
0 |
|
N/A |
| Clause 5(Marking) |
- |
2000 |
|
N/A |
| Clause 6(Operating Life Test) |
- |
2000 |
|
N/A |
| Clause 4.1, Table-1, i) a)(Hardware specification) |
- |
2000 |
|
N/A |
| Clause 4.1, Table-1, i) b)(Decompression and decoding of SDTV video) |
- |
2000 |
|
N/A |
| Clause 4.1, Table-1, i) c)(Decompression and decoding of HDTV video) |
- |
2000 |
|
N/A |
| Clause 4.1, Table-1, i) d)(Decompression and decoding of audio) |
- |
2000 |
|
N/A |
| Clause 4.1, Table-1, i) e)(Active Format descriptors) |
- |
2000 |
|
N/A |
| Clause 4.1, Table-1, i) f)(Captioning and Sub-titling) |
- |
2000 |
|
N/A |
| Clause 4.1, Table-1, i) g)(Teletext) |
- |
2000 |
|
N/A |
| Clause 4.1, Table-1, i) h)(Multi-language support) |
- |
2000 |
|
N/A |
| Clause 4.1, Table-1, i) j)(DTV receiver mixed Audio Description) |
- |
3000 |
|
N/A |
| Clause 4.1, Table-1, i) k)(Broadcast mixed audio description) |
- |
2000 |
|
N/A |
| Clause 4.1, Table-1, i) m)(Service demultiplexing) |
- |
3000 |
|
N/A |
| Clause 4.1, Table-1, i) n)(Data services) |
- |
3000 |
|
N/A |
| Clause 4.1, Table-1, i) p)(OSD) |
- |
3000 |
|
N/A |
| Clause 4.1, Table-1, i) q)(DTV character set) |
- |
3000 |
|
N/A |
| Clause 4.1, Table-1, i) r)(Electronic Service Guide (ESG) ‘Now/Next’) |
- |
2000 |
|
N/A |
| Clause 4.1, Table-1, i) s)(Time) |
- |
3000 |
|
N/A |
| Clause 4.1, Table-1, i) t)(Digital TV output) |
- |
3000 |
|
N/A |
| Clause 4.4, Table-2, i) b)(Frequency) |
- |
2000 |
|
N/A |
| Clause 4.4, Table-2, i) a)(Input voltage range) |
- |
3000 |
|
N/A |
| Clause 4.1,Table-1, ii) a)(Demodulation and FEC decoding) |
- |
3000 |
|
N/A |
| Clause 4.1, Table-1, ii) b)(DTV Receiver Installation) |
- |
3000 |
|
N/A |
| Clause 4.1, Table-1, ii) c)(Network evolution) |
- |
2000 |
|
N/A |
| Clause 4.4, Table-2, iii) c)(RF input impedance) |
- |
1000 |
|
N/A |
| Clause 4.1, Table-1, ii) d)(Services available) |
- |
3000 |
|
N/A |
| Clause 4.1, Table-1, ii) e)(Selection via Service List) |
- |
2000 |
|
N/A |
| Clause 4.1, Table-1, ii) f)(Selection via Numeric Entry) |
- |
2000 |
|
N/A |
| Clause 4.1, Table-1, ii) g)(Favourite Channel list) |
- |
3000 |
|
N/A |
| Clause 4.1, Table-1, ii) h)(Hidden Services) |
- |
2000 |
|
N/A |
| Clause 4.4, Table-2, iii) b)(Input frequency range) |
- |
2000 |
|
N/A |
| Clause 4.1, Table-1, ii) j)(Logical Channel Number for Satellite services) |
- |
2000 |
|
N/A |
| Clause 4.1, Table-1, ii) k)(RF input signal) |
- |
2000 |
|
N/A |
| Clause 4.1, Table-1, ii) m)(LNB supply current) |
- |
2000 |
|
N/A |
| Clause 4.1, Table-1, ii) n)(LNB supply voltage) |
- |
2000 |
|
N/A |
| Clause 4.1, Table-1, ii) p)(LNB Control) |
- |
2000 |
|
N/A |
| Clause 4.1, Table-1, ii) q)(Modulation/Demodulation parameters for DVB-S & DVB-S2 standard) |
- |
2000 |
|
N/A |
| Clause 4.4, Table-2, iii) a)(Input level per carrier) |
- |
2000 |
|
N/A |
| Clause 4.4, Table-2, iv) c)(RF input impedance) |
- |
2000 |
|
N/A |
| Clause 4.4, Table-2, iv) b)(Input frequency range) |
- |
2000 |
|
N/A |
| Clause 4.4, Table-2, iv) a)(Input level per carrier) |
- |
2000 |
|
N/A |
| Clause 4.4, Table-2, v)(Symbol rate) |
- |
2000 |
|
N/A |
| Clause 4.4, Table-2, vi)(RF input return loss) |
- |
2000 |
|
N/A |
| Clause 4.4, Table-2, vii)(DisEqC) |
- |
2000 |
|
N/A |
| Clause 4.4, Table-2, viii)(Operating ambient temperature range) |
- |
2000 |
|
N/A |
| Clause 4.4, Table-2, ix)(Operating humidity range) |
- |
2000 |
|
N/A |
| Clause 4.1, Table-1, iii) a)(Interfaces, Connectors) |
- |
2000 |
|
N/A |
| Clause 4.1, Table-1, iv)(Automatic software upgrade mechanism) |
- |
1000 |
|
N/A |
| Clause 4.1, Table-1, v) a)(Remote Control) |
- |
1000 |
|
N/A |
| Clause 4.1, Table-1, v) b)(Easy to use and simple documentation) |
- |
1000 |
|
N/A |
| Clause 3.1, Table-1, v) c)(Support package) |
- |
1000 |
|
N/A |
|
02 Sep, 2028 |
- 1 Clause 4.6 (Electromagnetic Compatibility (EMC) Requirements) Electromagnetic Compatibility (EMC) Requirements Test facility not avaliable. |
| 9 |
IS 616 (2017) |
Audio, video and similar electronic apparatus - Safety requirements (Fifth Revision) |
-- |
35000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 5(Marking and instructions) |
- |
250 |
|
N/A |
| 6(Hazardous radiations) |
- |
0 |
|
N/A |
| 7(Heating under normal operating conditions) |
- |
250 |
|
N/A |
| 8(Constructional requirements with regard to the protection against electric shock) |
- |
250 |
|
N/A |
| 9(Electric shock hazard under normal operating conditions) |
- |
250 |
|
N/A |
| 10(Insulation requirements) |
- |
250 |
|
N/A |
| 11(Fault conditions) |
- |
250 |
|
N/A |
| 12(Mechanical strength) |
- |
250 |
|
N/A |
| 13(CLEARANCES and CREEPAGE DISTANCES) |
- |
500 |
|
N/A |
| 14(Components) |
- |
500 |
|
N/A |
| 15(TERMINALS) |
- |
500 |
|
N/A |
| 16(External flexible cords) |
- |
250 |
|
N/A |
| 17(Electrical connections and mechanical fixings) |
- |
250 |
|
N/A |
| 18(Mechanical strength of picture tubes and protection against the effects of implosion) |
- |
0 |
|
N/A |
| 19(Stability and mechanical hazards) |
- |
500 |
|
N/A |
| 20(Resistance to fire) |
- |
500 |
|
N/A |
| 6.1(Ionizing radiation) |
- |
0 |
|
N/A |
| 6.2(Laser Radiation) |
- |
0 |
|
N/A |
| 6.3() |
- |
0 |
|
N/A |
| 8.16/ H 2.2/ H 2.3(Requirements for insulated winding wires for use without additional interleaved insulation) |
- |
0 |
|
N/A |
| 8.16(Wound Component) |
- |
0 |
|
N/A |
| 14(Components) |
- |
0 |
|
N/A |
| 15(Internal wires and power cords) |
- |
500 |
|
N/A |
| 16.3b(Cord Bending Test) |
- |
250 |
|
N/A |
| 18(Mechanical strength of Picture tubes and protection against the effect of implosion) |
- |
0 |
|
N/A |
| 20.2.4(Printed Boards) |
- |
250 |
|
N/A |
| 3(General requirements) |
- |
100 |
|
N/A |
| 4(General test conditions) |
- |
100 |
|
N/A |
| Annex-A(Additional requirements for apparatus with protection against splashing water) |
- |
500 |
|
N/A |
| Annex-B(Apparatus to be connected to the TELECOMMUNICATION NETWORKS) |
- |
250 |
|
N/A |
| Annex-L(Additional requirements for electronic flash apparatus for photographic purposes) |
- |
250 |
|
N/A |
| Cl.5.1 of Cl.5(General requirements) |
- |
100 |
|
N/A |
| Cl.5.1-i) of Cl.5(Comprehensible and easily discernible) |
- |
100 |
|
N/A |
| Cl.5.1-ii) of Cl.5(Permanent durability against water and petroleum spirit) |
- |
100 |
|
N/A |
| Cl.5.2 of Cl.5(Identification and supply ratings) |
- |
100 |
|
N/A |
| Cl.5.2 a) of Cl.5(Identification, maker) |
- |
100 |
|
N/A |
| Cl.5.2 b) of Cl.5(Model number or type reference) |
- |
100 |
|
N/A |
| Cl.5.2 d) of Cl.5(Nature of supply) |
- |
100 |
|
N/A |
| Cl.5.2 e) of Cl.5(Rated supply voltage) |
- |
100 |
|
N/A |
| Cl.5.2 f) of Cl.5(Mains frequency if safety dependant) |
- |
100 |
|
N/A |
| Cl.5.2 g) of Cl.5(Rated current or power consumption for apparatus supplied by supply apparatus for general use, on apparatus or in instruction manual: Measured current or power consumption: Deviation % (max 10%):) |
- |
100 |
|
N/A |
| Cl.5.2 h) of Cl.5(Rated current or power consumption for apparatus intended for connection to an a.c. mains supply:Measured current or power consumption for Television set: Deviation % (max 10%):) |
- |
100 |
|
N/A |
| Cl.5.2 h)-i) of Cl.5(appliance coupler for Class I is used for Class II equipment with functional earth connection, the requirements of Clause 15 and Clause 16 related to Class I construction shall be applied up to the connecting point of the protective(earthing) conductor to the functional earth.) |
- |
100 |
|
N/A |
| Cl.5.2 h)-ii) of Cl.5(Graphical symbols placed on the apparatus, whether required by this standard or not, shall be in accordance with IEC 60417 or ISO 3864-2 or ISO 7000, if available. In the absence of suitable symbols, the manufacturer may design specific graphical symbols.) |
- |
100 |
|
N/A |
| Cl.5.2 h)-iii) of Cl.5(Care shall be taken so that additional markings and instructions not required by this standard do not contradict the markings and instructions required by this standard . Symbols placed on the Equipment shall be explained in the user manual.) |
- |
100 |
|
N/A |
| Cl.5.3 of Cl.5(Terminals) |
- |
100 |
|
N/A |
| Cl.5.3a) of Cl.5(Earth terminal) |
- |
100 |
|
N/A |
| Cl.5.3b) of Cl.5(Hazardous live terminals) |
- |
100 |
|
N/A |
| Cl.5.3c) of Cl.5(Markings on supply output terminals) |
- |
100 |
|
N/A |
| Cl.5.4 of Cl.5(Caution marking) |
- |
100 |
|
N/A |
| Cl.5.4a) of Cl.5(Use of triangle with exclamation mark) |
- |
100 |
|
N/A |
| Cl.5.4b) of Cl.5(Marking on loudspeaker grille, IEC 60417-5036) |
- |
100 |
|
N/A |
| Cl.5.4c) of Cl.5(User-replaceable coin / button cell battery marking) |
- |
100 |
|
N/A |
| Cl.5.5 of Cl.5(Instructions) |
- |
0 |
|
N/A |
| Cl.5.5 of Cl.5(Instructions) |
- |
0 |
|
N/A |
| Cl.5.5 of Cl.5(Instructions) |
- |
0 |
|
N/A |
| Cl.5.5.1 of Cl.5.5(Safety relevant information) |
- |
100 |
|
N/A |
| Cl.5.5.2 a) of Cl.5.5(Mains powered equipment not exposed to dripping or splashing. Warning concerning objects filled with liquid, etc.) |
- |
0 |
|
N/A |
| Cl.5.5.2 b) of Cl.5.5(Hazardous live terminals, instructions for wiring) |
- |
100 |
|
N/A |
| Cl.5.5.2 c) of Cl.5.5(Instructions for replacing lithium battery) |
- |
0 |
|
N/A |
| Cl.5.5.2 d) of Cl.5.5(Class I earth connection warning) |
- |
0 |
|
N/A |
| Cl.5.5.2 e) of Cl.5.5(Instructions for multimedia system connection) |
- |
0 |
|
N/A |
| Cl.5.5.2 f) of Cl.5.5(Special stability warning for attachment of the apparatus to the floor/wall) |
- |
0 |
|
N/A |
| Cl.5.5.2 g) of Cl.5.5(Warning: battery exposure to heat) |
- |
0 |
|
N/A |
| Cl.5.5.2 h) of Cl.5.5(Warning: protective film on CRT face) |
- |
100 |
|
N/A |
| Cl.5.5.2 i) of Cl.5.5("Warning: Non-floor standing TV
>7kg") |
- |
100 |
|
N/A |
| Cl.5.5.2 j) of Cl.5.5("Warning: User replaceable coin
/ button cell battery") |
- |
100 |
|
N/A |
| Cl.5.5.3 (a-b) of Cl.5.5(Disconnect device: plug/coupler or all-pole mains switch location, accessibility and markings) |
- |
100 |
|
N/A |
| Cl.5.5.3 c) of Cl.5.5(Instructions for permanently connected equipment) |
- |
100 |
|
N/A |
| Cl.5.5.3 c) i) of Cl.5.5(Marking, signal lamps or similar for completely disconnection from the mains) |
- |
0 |
|
N/A |
| Cl.7.1 of Cl.7(General) |
- |
250 |
|
N/A |
| "Cl.7.1.1 of Cl.7.1 Table-3"(Requirements) |
- |
250 |
|
N/A |
| "Cl.7.1.2 of Cl.7.1 Table-3"(Accessible parts) |
- |
100 |
|
N/A |
| "Cl.7.1.3 of Cl.7.1 Table-3"(Parts, other than windings and printed boards, providing electrical insulation) |
- |
100 |
|
N/A |
| "Cl.7.1.4 of Cl.7.1 Table-3"(Parts acting as a support or a mechanical barrier) |
- |
100 |
|
N/A |
| "Cl.7.1.5 of Cl.7.1 Table-3"(Windings) |
- |
100 |
|
N/A |
| "Cl.7.1.6 of Cl.7.1 Table-3"(Parts not subject to a limit under7.1.1 to 7.1.4) |
- |
100 |
|
N/A |
| Cl.7.2 of Cl.7(Softening temperature of insulating material supporting parts conductively connected to the mains carrying a current> 0.2 A, shall be at least 150ºC) |
- |
100 |
|
N/A |
| Cl.8.1 of Cl.8(Conductive parts covered by lacquer, paper, untreated textile oxide films and beads etc. considered to be bare*) |
- |
250 |
|
N/A |
| Cl.8.2 of Cl.8(No shock hazard when changing voltage setting device, fuse-links or handling drawers etc.) |
- |
250 |
|
N/A |
| Cl.8.3 of Cl.8(Insulation of hazardous live parts not provided by hygroscopic material) |
- |
100 |
|
N/A |
| Cl.8.4 of Cl.8(No risk of electric shock from accessible parts or from parts rendered accessible following the removal of a cover which can be removed by hand) |
- |
100 |
|
N/A |
| Cl.8.5 of Cl.8(Class I apparatus*) |
- |
100 |
|
N/A |
| Cl.8.5 i) of Cl.8(Basic insulation between hazardous live parts and earthed accessible parts *) |
- |
100 |
|
N/A |
| Cl.8.5 ii) of Cl.8(Resistors bridging basic insulation shall complying with 14.1 a) *) |
- |
100 |
|
N/A |
| Cl.8.5 iii) of Cl.8(Capacitors bridging basic insulation shall complying with 14.2.1 a) *) |
- |
100 |
|
N/A |
| Cl.8.5 iv) of Cl.8(Protective earthing terminal *) |
- |
100 |
|
N/A |
| Cl.8.6 of Cl.8(Class II apparatus) |
- |
100 |
|
N/A |
| Cl.8.6 a) of Cl.8(Basic and supplementary insulation between hazardous live parts and accessible parts *) |
- |
100 |
|
N/A |
| Cl.8.6 b) of Cl.8(Reinforced insulation between hazardous live parts and accessible parts *) |
- |
0 |
|
N/A |
| Cl.8.7 of Cl.8(Components bridging insulation) |
- |
100 |
|
N/A |
| Cl.8.7 i) of Cl.8(Basic insulation bridged by components complying with 14.4.5.3) |
- |
100 |
|
N/A |
| Cl.8.7 ii) of Cl.8(Components bridging basic, supplementary, double or reinforced insulation complying with 14.2 a) or 14.4) |
- |
100 |
|
N/A |
| Cl.8.7 iii) of Cl.8(Basic and supplementary insulation each being bridged by a capacitor or RC-unit complying with 14.3.2 a)) |
- |
0 |
|
N/A |
| Cl.8.7 iv) of Cl.8(Double or reinforced insulation being bridged with 2 capacitors or RC-units in series complying with 14.3.2 a)) |
- |
0 |
|
N/A |
| Cl.8.7 v) of Cl.8(Double or reinforced insulation being bridged with a single capacitor or RC-unit complying with 14.3.2 b)) |
- |
100 |
|
N/A |
| Cl.8.8 of Cl.8(Insulation thickness and thin sheet materials) |
- |
100 |
|
N/A |
| Cl.8.8 i) of Cl.8(Basic or supplementary insulation > 0,4 mm (mm)*) |
- |
100 |
|
N/A |
| Cl.8.8 ii) of Cl.8(Reinforced insulation > 0,4 mm (mm) *) |
- |
100 |
|
N/A |
| Cl.8.8 iii) of Cl.8(Thin sheet material used inside the equipment) |
- |
0 |
|
N/A |
| Cl.8.8 iv) of Cl.8(Basic or supplementary insulation, atleast two layers, each meeting10.4) |
- |
0 |
|
N/A |
| Cl.8.8 v) of Cl.8(Basic or supplementary insulation, three layers any two of which meet10.4) |
- |
0 |
|
N/A |
| Cl.8.8 vi) of Cl.8(Reinforced insulation, two layers each of which meet 10.4) |
- |
100 |
|
N/A |
| Cl.8.9 of Cl.8(Adequate insulation between internal hazardous live conductors and accessible parts, or between internal hazardous live parts and conductors connected to accessible parts) |
- |
100 |
|
N/A |
| Cl.8.10 of Cl.8(Double insulation between accessible parts and conductors connected to the mains) |
- |
100 |
|
N/A |
| Cl.8.10 of Cl.8(Double insulation between conductors connected to accessible parts and parts connected to the mains) |
- |
100 |
|
N/A |
| Cl.8.11 of Cl.8(Detaching of wires) |
- |
100 |
|
N/A |
| Cl.8.11 i) of Cl.8(Noun due reduction of creepage or clearance distances if wires become detached) |
- |
0 |
|
N/A |
| Cl.8.11 ii) of Cl.8(Vibration test carried out) |
- |
500 |
|
N/A |
| Cl.8.12 of Cl.8(Adequate fastening of windows, lenses, lamp covers etc. (pull test 20 N for 10 s)) |
- |
0 |
|
N/A |
| Cl.8.13 of Cl.8(Adequate fastening of windows, lenses, lamp covers etc. (pull test 20 N for 10 s)) |
- |
0 |
|
N/A |
| Cl.8.14 of Cl.8(No risk of damage to the insulation of internal wiring due to hot parts or sharp edges) |
- |
100 |
|
N/A |
| Cl.8.15 of Cl.8(Only special supply equipment can be used*) |
- |
0 |
|
N/A |
| Cl.8.16 of Cl.8(Insulated winding wire without additional interleaved insulation) |
- |
0 |
|
N/A |
| Cl.8.18 of Cl.8(Disconnection from the mains) |
- |
0 |
|
N/A |
| Cl.8.18 i) of Cl.8(Disconnect device used in apparatus) |
- |
100 |
|
N/A |
| Cl.8.18 ii) of Cl.8(All-pole switch or circuit breaker with >3mm contact separation.) |
- |
100 |
|
N/A |
| Cl.8.18 iii) of Cl.8(Mains switch ON indication *) |
- |
0 |
|
N/A |
| Cl.8.19 of Cl.8(Switch not fitted in the mains cord *) |
- |
0 |
|
N/A |
| Cl.8.20 of Cl.8(Bridging components comply with clause 14) |
- |
0 |
|
N/A |
| Cl.8.21 of Cl.8(Non-separable thin sheet material) |
- |
0 |
|
N/A |
| Cl.9.1 of Cl.9(Testing on the outside) |
- |
250 |
|
N/A |
| Cl.9.1.1 of Cl.9.1(Requirements) |
- |
250 |
|
N/A |
| Cl.9.1.1 i) of Cl.9.1(Accessible parts shall not be hazardous live) |
- |
100 |
|
N/A |
| Cl.9.1.1 ii) of Cl.9.1(Inaccessible terminals are not accessible or comply with relevant requirements) |
- |
100 |
|
N/A |
| Cl.9.1.1 iii) of Cl.9.1(For voltages >1000 V ac or >1500 V dc complies with clause 13.3.1 for basic insulation) |
- |
100 |
|
N/A |
| Cl.9.1.1.2 of Cl.9.1.1(Determination of hazardous live parts) |
- |
100 |
|
N/A |
| Cl.9.1.1.2 a) of Cl.9.1.1(Open circuit voltages) |
- |
100 |
|
N/A |
| Touch current measured from terminal devices using the network in annex D(Touch current measured from terminal devices using the network in annex D) |
- |
100 |
|
N/A |
| Cl.9.1.1.2 c) of Cl.9.1.1(The charge exceeds 45 μC) |
- |
100 |
|
N/A |
| Cl.9.1.1.2 d) of Cl.9.1.1(Energy of discharge not exceeding 350 mJ) |
- |
0 |
|
N/A |
| Cl.9.1.1.3 of Cl.9.1.1(Test with test finger and test probe) |
- |
100 |
|
N/A |
| Cl.9.1.2 of Cl.9.1(Shafts of operating knobs, handles, levers and the like) |
- |
100 |
|
N/A |
| Cl.9.1.3 of Cl.9.1(Openings ofthe enclosure) |
- |
0 |
|
N/A |
| Cl.9.1.4 of Cl.9.1(Terminals) |
- |
0 |
|
N/A |
| Cl.9.1.4 i) of Cl.9.1(Terminals) |
- |
100 |
|
N/A |
| Cl.9.1.4 ii) of Cl.9.1(Terminals) |
- |
100 |
|
N/A |
| Cl.9.1.5 of Cl.9.1(Pre-set controls) |
- |
100 |
|
N/A |
| Cl.9.1.6 of Cl.9.1(Withdrawal of the mains plug:) |
- |
0 |
|
N/A |
| Cl.9.1.6 i) of Cl.9.1(Withdrawal of the mains plug:) |
- |
0 |
|
N/A |
| Cl.9.1.6 ii) of Cl.9.1(Withdrawal of the mains plug:) |
- |
0 |
|
N/A |
| Cl.9.1.6 iii) of Cl.9.1(Withdrawal of the mains plug:) |
- |
0 |
|
N/A |
| Cl.9.1.7 of Cl.9.1(Resistance to external forces) |
- |
250 |
|
N/A |
| Cl.9.1.7 a) of Cl.9.1(Resistance to external forces) |
- |
100 |
|
N/A |
| Cl.9.1.7 b) of Cl.9.1(Resistance to external forces) |
- |
100 |
|
N/A |
| Cl.9.1.7 c) of Cl.9.1(Resistance to external forces) |
- |
100 |
|
N/A |
| Cl.9.2 of Cl.9(Removal of protective covers) |
- |
100 |
|
N/A |
| Cl.10.2 of Cl.10(Surge Test) |
- |
300 |
|
N/A |
| Cl.10.2 a) of Cl.10(Surge Test) |
- |
100 |
|
N/A |
| Cl.10.2 b) of Cl.10(Surge Test) |
- |
100 |
|
N/A |
| Cl.10.2 b) (i) of Cl.10(Surge Test) |
- |
100 |
|
N/A |
| Cl.10.2 b) (ii) of Cl.10(Surge Test) |
- |
100 |
|
N/A |
| Cl.10.2 b) (iii) of Cl.10(Surge Test) |
- |
100 |
|
N/A |
| Cl.10.3 of Cl.10(Humidity treatment) |
- |
100 |
|
N/A |
| Cl.10.4 of Cl.10(Insulation resistance and dielectric strength) |
- |
250 |
|
N/A |
| Cl.10.4.1 of Cl.10.4(Insulation of the insulating materials) |
- |
100 |
|
N/A |
| Cl.10.4.2 of Cl.10.4(Between parts of different polarity directly connected to the mains
Between parts of different polarity directly connected to the mains) |
- |
100 |
|
N/A |
| Cl.10.4.2 i) of Cl.10.4(Between parts separated by BASIC or SUPPLEMENTARY insulation) |
- |
100 |
|
N/A |
| Cl.10.4.2 ii) of Cl.10.4(Between parts separated by REINFORCED insulation) |
- |
100 |
|
N/A |
| Cl.11.1 of Cl.11(Electric Shock Hazard) |
- |
100 |
|
N/A |
| Cl.11.1 a) of Cl.11(Electric Shock Hazard) |
- |
150 |
|
N/A |
| Cl.11.1 b) of Cl.11(Electric Shock Hazard) |
- |
100 |
|
N/A |
| Cl.11.2 of Cl.11(Heating) |
- |
250 |
|
N/A |
| Cl.11.2.1 of Cl.11.2(Requirements) |
- |
0 |
|
N/A |
| Cl.11.2.1 i) of Cl.11.2(No danger of fire to the surroundings) |
- |
100 |
|
N/A |
| Cl.11.2.1 ii) of Cl.11.2(Safety not impaired by abnormal heat) |
- |
100 |
|
N/A |
| Cl.11.2.1 of Cl.11.2(Flames extinguish within 10 seconds) |
- |
100 |
|
N/A |
| Cl.11.2.1 of Cl.11.2(No hazard from softening solder) |
- |
100 |
|
N/A |
| Cl.11.2.1 of Cl.11.2(Soldered terminations not used as protective mechanism) |
- |
100 |
|
N/A |
| Cl.11.2.2 of Cl.11.2(Measurement of temperature rises) |
- |
100 |
|
N/A |
| Cl.11.2.3 of Cl.11.2(Accessible parts) |
- |
100 |
|
N/A |
| Cl.11.2.4 of Cl.11.2(Parts, other than windings and printed boards, providing electrical insulation) |
- |
100 |
|
N/A |
| Cl.11.2.5 of Cl.11.2(Parts acting as a support or a mechanical barrier) |
- |
100 |
|
N/A |
| Cl.11.2.6 of Cl.11.2(Windings ) |
- |
100 |
|
N/A |
| Cl.11.2.7 of Cl.11.2(Printed boards) |
- |
100 |
|
N/A |
| Cl.11.2.7 i) of Cl.11.2(Printed boards) |
- |
100 |
|
N/A |
| Cl.11.2.7 i) a) of Cl.11.2(Printed boards) |
- |
100 |
|
N/A |
| Cl.11.2.7 i) b) of Cl.11.2(Printed boards) |
- |
100 |
|
N/A |
| Cl.11.2.7 ii) of Cl.11.2(Printed boards) |
- |
0 |
|
N/A |
| Cl.11.2.7 iii) of Cl.11.2(Printed boards) |
- |
0 |
|
N/A |
| Cl.11.2.8 of Cl.11.2(Parts not subject to a limit under7.1.1 to 7.1.4) |
- |
0 |
|
N/A |
| Cl.12.1.1 of Cl.12.1(Requirements) |
- |
0 |
|
N/A |
| Cl.12.1.2 of Cl.12.1(Bump test ) |
- |
250 |
|
N/A |
| Cl.12.1.3 of Cl.12.1(Vibration test) |
- |
250 |
|
N/A |
| Cl.12.1.4 of Cl.12.1(Impact test) |
- |
250 |
|
N/A |
| Cl.12.1.4 i) of Cl.12.1(Impact test) |
- |
100 |
|
N/A |
| Cl.12.1.4 ii) of Cl.12.1(Impact test) |
- |
100 |
|
N/A |
| Cl.12.1.5 of Cl.12.1(Drop test) |
- |
100 |
|
N/A |
| Cl.12.1.6 of Cl.12.1(Stress relief test) |
- |
250 |
|
N/A |
| Cl.12.2 of Cl.12(Fixing of actuating elements) |
- |
100 |
|
N/A |
| Cl.12.3 of Cl.12(Remote control devices held in hand) |
- |
100 |
|
N/A |
| Cl.12.4 of Cl.12(Drawers ) |
- |
250 |
|
N/A |
| Cl.12.5 of Cl.12(Antenna coaxial sockets mounted on the apparatus) |
- |
250 |
|
N/A |
| Cl.12.5 a) of Cl.12(Endurance test,) |
- |
500 |
|
N/A |
| Cl.12.5 b) of Cl.12(Impact test,) |
- |
250 |
|
N/A |
| Cl.12.5 c) of Cl.12(Torque test) |
- |
100 |
|
N/A |
| Cl.12.6 of Cl.12(Telescoping or rod antennas) |
- |
100 |
|
N/A |
| Cl.12.6.1 of Cl.12.6(General requirements) |
- |
100 |
|
N/A |
| Cl.12.6.1 i) of Cl.12.6(General requirements) |
- |
100 |
|
N/A |
| Cl.12.6.2 of Cl.12.6(Physical securement) |
- |
100 |
|
N/A |
| Cl.12.7 of Cl.12(Apparatus containing coin / button cell batteries) |
- |
250 |
|
N/A |
| Cl.12.7.1 of Cl.12.7(Coin/button cell batteries with a diameter of 32 mm or less.) |
- |
100 |
|
N/A |
| Cl.12.7.2 of Cl.12.7(Construction requirementss) |
- |
250 |
|
N/A |
| Cl.12.7.3 of Cl.12.7(Tests) |
- |
100 |
|
N/A |
| Cl.12.7.3.2 of Cl.12.7.3(Stress relief test) |
- |
100 |
|
N/A |
| Cl.12.7.3.3 of Cl.12.7.3(Battery replacement test) |
- |
100 |
|
N/A |
| Cl.12.7.3.4 of Cl.12.7.3(Drop test) |
- |
100 |
|
N/A |
| Cl.12.7.3.5 of Cl.12.7.3(Impact test) |
- |
100 |
|
N/A |
| Cl.12.7.3.6 of Cl.12.7.3(Crush test) |
- |
100 |
|
N/A |
| Cl.12.7.4 of Cl.12.7(Compliance) |
- |
100 |
|
N/A |
| Cl.13.1 of Cl.13(General) |
- |
100 |
|
N/A |
| Cl.13.2 of Cl.13(Determination of Working voltage) |
- |
100 |
|
N/A |
| Cl.13.3 of Cl.13(Clearances) |
- |
100 |
|
N/A |
| Cl.13.3.1 of Cl.13.3(General) |
- |
100 |
|
N/A |
| Cl.13.3.2 of Cl.13.3(Clearances in circuits conductively connected to the mains) |
- |
100 |
|
N/A |
| Cl.13.3.3 of Cl.13.3(Clearances in circuits not conductively connected to the mains) |
- |
100 |
|
N/A |
| Cl.13.3.4 of Cl.13(Measurement of transient voltages) |
- |
100 |
|
N/A |
| Cl.13.4 a) of Cl.13(Creepage distances ) |
- |
100 |
|
N/A |
| Cl.13.4 b) of Cl.13(Creepage distances ) |
- |
100 |
|
N/A |
| Cl.13.4 c) of Cl.13(Creepage distances ) |
- |
100 |
|
N/A |
| Cl.13.6 a) of Cl.13(Jointed insulation ) |
- |
100 |
|
N/A |
| Cl.13.6 b) of Cl.13(Jointed insulation ) |
- |
100 |
|
N/A |
| Cl.13.6 c) of Cl.13(Jointed insulation ) |
- |
100 |
|
N/A |
| Cl.13.6 d) of Cl.13(Jointed insulation ) |
- |
100 |
|
N/A |
| Cl.13.7 of Cl.13(Enclosed and sealed parts) |
- |
100 |
|
N/A |
| Cl.13.8 of Cl.13(Parts filled with insulating compound, meeting the requirements of 8.8) |
- |
100 |
|
N/A |
| Cl.15.1 of Cl.15(Plugs and Sockets*) |
- |
250 |
|
N/A |
| Cl.15.1.1 of Cl.15.1(Plugs and Sockets*) |
- |
100 |
|
N/A |
| Cl.15.1.1 i) of Cl.15.1(Plugs and Sockets*) |
- |
100 |
|
N/A |
| Cl.15.1.1 ii) of Cl.15.1(Plugs and Sockets*) |
- |
100 |
|
N/A |
| Cl.15.1.2 of Cl.15.1(Design of connectors other than for mains power *) |
- |
100 |
|
N/A |
| Cl.15.1.2 i) of Cl.15.1(Design of sockets with symbol of 5.3 b) design *) |
- |
100 |
|
N/A |
| Cl.15.1.3 of Cl.15.1(Design of terminals and connectors used in output circuits of supply apparatus*) |
- |
100 |
|
N/A |
| Cl.15.2 of Cl.15(Provisions for protective earthing) |
- |
100 |
|
N/A |
| Cl.15.2 i) of Cl.15(Provisions for protective earthing) |
- |
100 |
|
N/A |
| Cl.15.2 ii) of Cl.15(Provisions for protective earthing) |
- |
100 |
|
N/A |
| Cl.15.2 iii) of Cl.15(Provisions for protective earthing) |
- |
100 |
|
N/A |
| Cl.15.2 iv) of Cl.15(Provisions for protective earthing) |
- |
250 |
|
N/A |
| Cl.15.2 v) of Cl.15(Provisions for protective earthing) |
- |
100 |
|
N/A |
| Cl.15.3 of Cl.15(Terminals for external flexible cords and for permanent connection to the mains supply*) |
- |
100 |
|
N/A |
| Cl.15.3.1 of Cl.15.3(Adequate terminals for connection of permanent wiring*) |
- |
100 |
|
N/A |
| Cl.15.3.2 of Cl.15.3(Reliable connection of non-detachable cords) |
- |
100 |
|
N/A |
| Cl.15.3.2 i) of Cl.15.3(Not soldered to conductors of a printed circuit board) |
- |
100 |
|
N/A |
| Cl.15.3.2 ii) of Cl.15.3(Adequate clearances and creepage distances between connections should a wire break away) |
- |
100 |
|
N/A |
| Cl.15.3.2 iii) of Cl.15.3(Wire secured by additional means to the conductor) |
- |
100 |
|
N/A |
| Cl.15.3.3 of Cl.15.3(Screws and nuts clamping conductors have adequate threads: ISO 261, ISO 262 or similar*) |
- |
100 |
|
N/A |
| Cl.15.3.4 of Cl.15.3(Conductors adequately fixed (two independent fixings) *) |
- |
100 |
|
N/A |
| Cl.15.3.5 of Cl.15.3(Terminals allow connection of conductors having appropriate cross-sectional area) |
- |
100 |
|
N/A |
| Cl.15.3.6 of Cl.15.3(Terminals to 15.3.3 have sizes required by table 16) |
- |
100 |
|
N/A |
| Cl.15.3.7 of Cl.15.3(Terminals clamp conductors between metal and have adequate pressure) |
- |
100 |
|
N/A |
| Cl.15.3.7 i) of Cl.15.3(Terminals designed to avoid conductor slipping out when tightened) |
- |
100 |
|
N/A |
| Cl.15.3.7 ii) of Cl.15.3(Terminals adequately fixed when tightened or loosened (no loosening, wiring not stressed, distances not reduced)) |
- |
100 |
|
N/A |
| Cl.15.3.8 of Cl.15.3(Terminals carrying a current more than) |
- |
100 |
|
N/A |
| Cl.15.3.8 i) of Cl.15.3(0.2 A, contact pressure not transmitted by insulating material except ceramic*) |
- |
100 |
|
N/A |
| Cl.15.3.9 of Cl.15.3(Termination of non-detachable cords: wires terminated near to each other) |
- |
100 |
|
N/A |
| Cl.15.3.9 i) of Cl.15.3(Terminals located and shielded: test with 8 mm strand) |
- |
100 |
|
N/A |
| Cl.15.4 of Cl.15(Devices forming a part of the mains plug*) |
- |
100 |
|
N/A |
| Cl.15.4.1 of Cl.15.4(No undue strain on mains socket-outlets.) |
- |
100 |
|
N/A |
| Cl.15.4.1 i) of Cl.15.4(Device shall be tested on the equipment as per Fig.11: Torque to be applied : 0.25 Nm (Max)) |
- |
100 |
|
N/A |
| Cl.15.4.2 of Cl.15.4(Device complies with standard for dimensions of mains plugs) |
- |
100 |
|
N/A |
| Cl.15.4.3 of Cl.15.4(Device has adequate mechanical strength (tests a,b,c)) |
- |
100 |
|
N/A |
| Cl.16.1 a) of Cl.16(Mains supply flexible cords shall be sheathed type, complying with IEC 60227 for PVC cords or as per IEC 60245 for synthetic rubber cords) |
- |
250 |
|
N/A |
| Cl.16.1 b) of Cl.16(Non-detachable cords for Class I have green/yellow core for protective earth) |
- |
250 |
|
N/A |
| Cl.16.2 of Cl.16(Mains cords conductors shall have a nominal cross-sectional area not less than the values given in Table 18, for rated current consumption of the apparatus) |
- |
100 |
|
N/A |
| Cl.16.3 a) of Cl.16(Flexiblecordsnotcomplyingwith16.1, used for interconnections between separate units of equipment used in combination and carrying hazardous live voltages, have adequate dielectric strength as perCl.10.3) |
- |
100 |
|
N/A |
| Cl.16.4 of Cl.16(Flexible cords used for connection between equipment have adequate cross-sectional areas to avoid temperature rise under normal and fault conditions) |
- |
100 |
|
N/A |
| Cl.16.5 a) of Cl.16(Adequate strain relief on external flexible cords) |
- |
100 |
|
N/A |
| Cl.16.5 b) of Cl.16(Not possible to push cord back into equipment) |
- |
100 |
|
N/A |
| Cl.16.5 c) of Cl.16(Strain relief device unlikely to damage flexible cord) |
- |
100 |
|
N/A |
| Cl.16.5 d) of Cl.16(For mains cords of Class I equipment, hazardous live conductors become taut before earth conductor) |
- |
100 |
|
N/A |
| Cl.16.6 of Cl.16(Apertures for external flexible cord: no risk of damage to the cord during assembly or movement in use) |
- |
100 |
|
N/A |
| Cl.16.7 a) of Cl.16(Transportable apparatus fitted with detachable cord sets with appliance inlet as perIEC60320-1 or) |
- |
100 |
|
N/A |
| Cl.16.7 b) of Cl.16(Transportable apparatus shall have a means of stowage to protect the cord) |
- |
100 |
|
N/A |
| 17.1 a) of Cl.17(Screws are loosened and then tightened with a torque according to table20) |
- |
250 |
|
N/A |
| Cl.17.1 b) of Cl.17(5 times in the case of screws operating in a thread of metal) |
- |
250 |
|
N/A |
| Cl.17.1 c) of Cl.17(10 times in the case of screws operating in wood or in a thread in insulating material:) |
- |
100 |
|
N/A |
| Cl.17.2 of Cl.17(Correct introduction of screws into female threads in non-metallic material) |
- |
100 |
|
N/A |
| Cl.17.3 a) of Cl.17(Screws or other fixing devices intended to fix Covers, legs, stands or the like, shall be captive in order to prevent replacement during servicing by screws or other fixing devices……) |
- |
100 |
|
N/A |
| Cl.17.3 b) of Cl.17(Non-captive fixing screws: no hazard when replaced by a screw whose length is 10 times its diameter) |
- |
100 |
|
N/A |
| Cl.17.4 of Cl.17(No loosening of conductive parts carrying a current > 0.2 A) |
- |
100 |
|
N/A |
| Cl.17.5 of Cl.17(Contact pressure not transmitted through plastic other than ceramic for connections carrying a current > 0.2 A*) |
- |
100 |
|
N/A |
| Cl.17.6 of Cl.17(Stranded conductors of flexible supply cords carrying a current > 0.2 A with screw terminals not consolidated by solder *) |
- |
100 |
|
N/A |
| Cl.17.7 of Cl.17(Cover fixing devices other than screws have adequate strength and their positioning is unambiguous) |
- |
100 |
|
N/A |
| Cl.17.8 of Cl.17(Detachable legs or stands supplied by the manufacturer of the apparatus shall be delivered with the relevant fixing means *) |
- |
100 |
|
N/A |
| Cl.17.9 a) of Cl.17(Internal pluggable connections, affecting safety, unlikely to become disconnected) |
- |
100 |
|
N/A |
| Cl.17.9 b) of Cl.17(By applying a 2N pull force in any direction to the connection, in case of doubt) |
- |
100 |
|
N/A |
| Cl.19.1 of Cl.19(Stability and mechanical hazards) |
- |
250 |
|
N/A |
| Cl.19.1 of Cl.19(Stability requirements) |
- |
100 |
|
N/A |
| Cl.19.1 i) of Cl.19(Stability requirements) |
- |
100 |
|
N/A |
| Cl.19.2 of Cl.19(Test at 10° to the horizontal) |
- |
100 |
|
N/A |
| Cl.19.3 of Cl.19(Vertical force test ) |
- |
100 |
|
N/A |
| Cl.19.4 of Cl.19(Horizontal force test) |
- |
100 |
|
N/A |
| Cl.19.5 of Cl.19(Test of edges and corners) |
- |
100 |
|
N/A |
| Cl.19.6 of Cl.19(Mechanical strength of glass) |
- |
0 |
|
N/A |
| Cl.19.6.1 of Cl.19.6(Requirements) |
- |
100 |
|
N/A |
| Cl.19.6.2 of Cl.19.6(Fragmentation test) |
- |
100 |
|
N/A |
| Cl.19.7 of Cl.19(Wall or ceiling mounting means) |
- |
100 |
|
N/A |
| Cl.19.7.1 of Cl.19..7(Requirements) |
- |
100 |
|
N/A |
| Cl.19.7.3 of Cl.19.7(Compliance) |
- |
0 |
|
N/A |
| Cl.20.1 of Cl.20(Requirements) |
- |
0 |
|
N/A |
| Cl.20.2 of Cl.20(Electrical components and mechanical parts) |
- |
100 |
|
N/A |
| Cl.20.2.1 a) of Cl.20.2(Exemption for components contained in an enclosure of material V-0 to IEC60695- 11-10 with openings not exceeding 1 mm in width) |
- |
0 |
|
N/A |
| Cl.20.2.1 b) of Cl.20.2(Exemption for small components) |
- |
0 |
|
N/A |
| Cl.20.2.2 of Cl.20.2(Electrical components ) |
- |
100 |
|
N/A |
| Cl.20.2.3 of Cl.20.2(Internal wiring) |
- |
250 |
|
N/A |
| Cl.20.2.4 of Cl.20.2(Printed boards) |
- |
100 |
|
N/A |
| Cl.20.2.4 i) of Cl.20.2(Printed boards) |
- |
0 |
|
N/A |
| Cl.20.2.5 of Cl.20.2(Components and parts not covered by 20.2.2, 20.2.3 and 20.2.4) |
- |
0 |
|
N/A |
| Cl.20.2.5 i) of Cl.20.2(Components and parts not covered by 20.2.2, 20.2.3 and 20.2.4) |
- |
0 |
|
N/A |
| Cl.20.2.5 ii) of Cl.20.2(Components and parts not covered by 20.2.2, 20.2.3 and 20.2.4) |
- |
0 |
|
N/A |
| Cl.20.3 of Cl.20(Fire enclosure*) |
- |
100 |
|
N/A |
| Cl.20.3.1 of Cl.20.3(Fire enclosure*) |
- |
0 |
|
N/A |
| Cl.20.3.2 of Cl.20.3(Fire enclosure*) |
- |
0 |
|
N/A |
| Cl.20.3.3 of Cl.20.3(Fire enclosure*) |
- |
0 |
|
N/A |
|
02 Sep, 2028 |
- Included w.e.f 31.12.2025
Exclusion: 6 (Hazardous radiations)
14 (Components)
18 (Mechanical strength of picture tubes and protection against the effects of implosion)
6.1 (Ionizing radiation)
6.2 (Laser Radiation)
6.3 Light emitting diodes (LEDs) Lab has no test facility
8.16/ H 2.2/ H 2.3 (Requirements for insulated winding wires for use without additional interleaved insulation)
8.16 (Wound Component) |
| 10 |
IS 13252 : Part 1 (2010) |
Information technology equipment - Safety: Part 1 general requirements (Second Revision) |
-- |
35000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 1.5(Components) |
- |
0 |
|
N/A |
| 1.6(Power interface .) |
- |
500 |
|
N/A |
| 1.7(Markings and instructions) |
- |
500 |
|
N/A |
| 2.1(Protection from electric shock and energy hazards) |
- |
500 |
|
N/A |
| 2.2(SELV circuits) |
- |
500 |
|
N/A |
| 2.3(TNV circuits) |
- |
500 |
|
N/A |
| 2.4(Limited current circuits) |
- |
500 |
|
N/A |
| 2.5(Limited power sources .) |
- |
500 |
|
N/A |
| 2.6(Provisions for earthing and bonding) |
- |
500 |
|
N/A |
| 2.7(Overcurrent and earth fault protection in primary circuits) |
- |
500 |
|
N/A |
| 2.8(Safety interlocks) |
- |
500 |
|
N/A |
| 2.9(Electrical insulation) |
- |
500 |
|
N/A |
| 2.10(Clearances, creepage distances and distances through insulation) |
- |
500 |
|
N/A |
| 3.1(General) |
- |
500 |
|
N/A |
| 3.2(Connection to a mains supply) |
- |
500 |
|
N/A |
| 3.3(Wiring terminals for connection of external conductors) |
- |
500 |
|
N/A |
| 3.4(Disconnection from the mains supply) |
- |
500 |
|
N/A |
| 3.5(Interconnection of equipment) |
- |
500 |
|
N/A |
| 4.1(Stability) |
- |
500 |
|
N/A |
| 4.2(Mechanical strength) |
- |
500 |
|
N/A |
| 4.3(Design and construction) |
- |
500 |
|
N/A |
| 4.4(Protection against hazardous moving parts) |
- |
500 |
|
N/A |
| 4.5(Thermal requirements) |
- |
500 |
|
N/A |
| 4.6(Openings in enclosures) |
- |
500 |
|
N/A |
| 4.7(Resistance to fire) |
- |
1000 |
|
N/A |
| 5.1(Touch current and protective conductor curren) |
- |
1000 |
|
N/A |
| 5.2(Electric strength) |
- |
1000 |
|
N/A |
| 5.3(Abnormal operating and fault conditions) |
- |
500 |
|
N/A |
| 6.1(Protection of telecommunication network service persons, and users of other equipment connected to the network, from hazards in the equipment) |
- |
1000 |
|
N/A |
| 6.2(Protection of equipment users from overvoltages on networks telecommunication) |
- |
1000 |
|
N/A |
| 6.3(Protection of the telecommunication wiring system from overheating) |
- |
500 |
|
N/A |
| 7.1(General) |
- |
0 |
|
N/A |
| 7.2(Protection of cable distribution system service persons, and users of other equipment connected to the system, from hazardous voltages in the equipment) |
- |
1000 |
|
N/A |
| 7.3(Protection of equipment users from overvoltages on the cable distribution system) |
- |
1000 |
|
N/A |
| 7.4(Insulation between primary circuits and cable distribution systems) |
- |
1000 |
|
N/A |
| 1.5(Components) |
- |
0 |
|
N/A |
| 2.8.2/2.8.5(Interlock switches) |
- |
0 |
|
N/A |
| 2.8.7(Switches and Relay) |
- |
0 |
|
N/A |
| 2.10.4.2(Material Group and Comparative Tracking Index) |
- |
1000 |
|
N/A |
| 2.10.5.3(Insulating Compound as Solid Insulation) |
- |
500 |
|
N/A |
| 2.10.5.4(Opto-coupler) |
- |
0 |
|
N/A |
| 2.10.5.6(Thin sheet materials) |
- |
1000 |
|
N/A |
| 2.10.5.11(SMPS Transformer and Inductor) |
- |
500 |
|
N/A |
| 2.10.5.12(Wires in wound components) |
- |
0 |
|
N/A |
| 2.10.5.13(Winding wire) |
- |
0 |
|
N/A |
| 2.10.5.14(Additional insulation in wound components) |
- |
0 |
|
N/A |
| 2.10.6(PCB material) |
- |
1000 |
|
N/A |
| 2.10.8.2(Thermal conditioning (thermal ageing)) |
- |
1000 |
|
N/A |
| 2.10.8.4(Abrasion resistance test) |
- |
500 |
|
N/A |
| 2.10.9(Thermal Cycling) |
- |
1000 |
|
N/A |
| 2.10.10(Test for Pollution Degree 1 environment and for insulating compound) |
- |
500 |
|
N/A |
| 2.10.11(Tests for semiconductor devices and for cemented joints) |
- |
0 |
|
N/A |
| 2.10.12(Enclosed and sealed parts) |
- |
0 |
|
N/A |
| 3.1.4(Internal wire) |
- |
500 |
|
N/A |
| 3.2.4(Appliance inlet /connector) |
- |
500 |
|
N/A |
| 3.2.4(Appliance inlet /connector) |
- |
500 |
|
N/A |
| 3.2.5(Non re-wirable plug with PVC sheathed cable) |
- |
500 |
|
N/A |
| 4.2.8(Cathode Ray Tubes) |
- |
0 |
|
N/A |
| 4.3.8(Batteries) |
- |
500 |
|
N/A |
| 4.3.10(Dust, powders, liquids and gases) |
- |
0 |
|
N/A |
| 4.3.11(Containers for liquids or gases) |
- |
0 |
|
N/A |
| 4.3.12(Flammable liquids) |
- |
0 |
|
N/A |
| 4.3.13.2(Ionizing radiation) |
- |
0 |
|
N/A |
| 4.3.13.3/ Annex Y(Effect of UV radiation on material/Ultraviolet conditioning test) |
- |
0 |
|
N/A |
| 4.3.13.4(Human exposure to ultraviolet (UV) radiation) |
- |
0 |
|
N/A |
| 4.3.13.5(LED, laser class) |
- |
0 |
|
N/A |
| Annex A3(Hot flaming oil test) |
- |
1000 |
|
N/A |
| Annex U(Insulating winding wires for use without interleaved insulation) |
- |
0 |
|
N/A |
| Annex CC(Evaluation of integrated circuit (IC) current limiters) |
- |
0 |
|
N/A |
| Annex K(Thermal Control) |
- |
0 |
|
N/A |
| Annex Q(Voltage Dependent Resistors) |
- |
0 |
|
N/A |
| Annex B(Motor tests under abnormal conditions) |
- |
1000 |
|
N/A |
| Annex C(Transformers) |
- |
1000 |
|
N/A |
| Annex DD(Requirements for the mounting means of a rack mounted equipment) |
- |
1000 |
|
N/A |
| Annex EE(Household and home/ office document/ media shredders) |
- |
0 |
|
N/A |
| 4.6.2(Bottoms of fire enclosures) |
- |
1000 |
|
N/A |
| 1.5(Components) |
- |
- |
|
- |
| 1.6(Power interface .) |
- |
- |
|
- |
| 1.7(Markings and instructions) |
- |
- |
|
- |
| 2.1(Protection from electric shock and energy hazards) |
- |
- |
|
- |
| 2.2(SELV circuits) |
- |
- |
|
- |
| 2.3(TNV circuits) |
- |
- |
|
- |
| 2.4(Limited current circuits) |
- |
- |
|
- |
| 2.5(Limited power sources .) |
- |
- |
|
- |
| 2.6(Provisions for earthing and bonding) |
- |
- |
|
- |
| 2.7(Overcurrent and earth fault protection in primary circuits) |
- |
- |
|
- |
| 2.8(Safety interlocks) |
- |
- |
|
- |
| 2.9(Electrical insulation) |
- |
- |
|
- |
| 2.10(Clearances, creepage distances and distances through insulation) |
- |
- |
|
- |
| 3.1(General) |
- |
- |
|
- |
| 3.2(Connection to a mains supply) |
- |
- |
|
- |
| 3.3(Wiring terminals for connection of external conductors) |
- |
- |
|
- |
| 3.4(Disconnection from the mains supply) |
- |
- |
|
- |
| 3.5(Interconnection of equipment) |
- |
- |
|
- |
| 4.1(Stability) |
- |
- |
|
- |
| 4.2(Mechanical strength) |
- |
- |
|
- |
| 4.3(Design and construction) |
- |
- |
|
- |
| 4.4(Protection against hazardous moving parts) |
- |
- |
|
- |
| 4.5(Thermal requirements) |
- |
- |
|
- |
| 4.6(Openings in enclosures) |
- |
- |
|
- |
| 4.7(Resistance to fire) |
- |
- |
|
- |
| 5.1(Touch current and protective conductor curren) |
- |
- |
|
- |
| 5.2(Electric strength) |
- |
- |
|
- |
| 5.3(Abnormal operating and fault conditions) |
- |
- |
|
- |
| 6.1(Protection of telecommunication network service persons, and users of other equipment connected to the network, from hazards in the equipment) |
- |
- |
|
- |
| 6.2(Protection of equipment users from overvoltages on networks telecommunication) |
- |
- |
|
- |
| 6.3(Protection of the telecommunication wiring system from overheating) |
- |
- |
|
- |
| 7.1(General) |
- |
- |
|
- |
| 7.2(Protection of cable distribution system service persons, and users of other equipment connected to the system, from hazardous voltages in the equipment) |
- |
- |
|
- |
| 7.3(Protection of equipment users from overvoltages on the cable distribution system) |
- |
- |
|
- |
| 7.4(Insulation between primary circuits and cable distribution systems) |
- |
- |
|
- |
| 1.5(Components) |
- |
- |
|
- |
| 2.8.2/2.8.5(Interlock switches) |
- |
- |
|
- |
| 2.8.7(Switches and Relay) |
- |
- |
|
- |
| 2.10.4.2(Material Group and Comparative Tracking Index) |
- |
- |
|
- |
| 2.10.5.3(Insulating Compound as Solid Insulation) |
- |
- |
|
- |
| 2.10.5.4(Opto-coupler) |
- |
- |
|
- |
| 2.10.5.6(Thin sheet materials) |
- |
- |
|
- |
| 2.10.5.11(SMPS Transformer and Inductor) |
- |
- |
|
- |
| 2.10.5.12(Wires in wound components) |
- |
- |
|
- |
| 2.10.5.13(Winding wire) |
- |
- |
|
- |
| 2.10.5.14(Additional insulation in wound components) |
- |
- |
|
- |
| 2.10.6(PCB material) |
- |
- |
|
- |
| 2.10.8.2(Thermal conditioning (thermal ageing)) |
- |
- |
|
- |
| 2.10.8.4(Abrasion resistance test) |
- |
- |
|
- |
| 2.10.9(Thermal Cycling) |
- |
- |
|
- |
| 2.10.10(Test for Pollution Degree 1 environment and for insulating compound) |
- |
- |
|
- |
| 2.10.11(Tests for semiconductor devices and for cemented joints) |
- |
- |
|
- |
| 2.10.12(Enclosed and sealed parts) |
- |
- |
|
- |
| 3.1.4(Internal wire) |
- |
- |
|
- |
| 3.2.4(Appliance inlet /connector) |
- |
- |
|
- |
| 3.2.4(Appliance inlet /connector) |
- |
- |
|
- |
| 3.2.5(Non re-wirable plug with PVC sheathed cable) |
- |
- |
|
- |
| 4.2.8(Cathode Ray Tubes) |
- |
- |
|
- |
| 4.3.8(Batteries) |
- |
- |
|
- |
| 4.3.10(Dust, powders, liquids and gases) |
- |
- |
|
- |
| 4.3.11(Containers for liquids or gases) |
- |
- |
|
- |
| 4.3.12(Flammable liquids) |
- |
- |
|
- |
| 4.3.13.2(Ionizing radiation) |
- |
- |
|
- |
| 4.3.13.3/ Annex Y(Effect of UV radiation on material/Ultraviolet conditioning test) |
- |
- |
|
- |
| 4.3.13.4(Human exposure to ultraviolet (UV) radiation) |
- |
- |
|
- |
| 4.3.13.5(LED, laser class) |
- |
- |
|
- |
| Annex A3(Hot flaming oil test) |
- |
- |
|
- |
| Annex U(Insulating winding wires for use without interleaved insulation) |
- |
- |
|
- |
| Annex CC(Evaluation of integrated circuit (IC) current limiters) |
- |
- |
|
- |
| Annex K(Thermal Control) |
- |
- |
|
- |
| Annex Q(Voltage Dependent Resistors) |
- |
- |
|
- |
| Annex B(Motor tests under abnormal conditions) |
- |
- |
|
- |
| Annex C(Transformers) |
- |
- |
|
- |
| Annex DD(Requirements for the mounting means of a rack mounted equipment) |
- |
- |
|
- |
| Annex EE(Household and home/ office document/ media shredders) |
- |
- |
|
- |
| 4.6.2(Bottoms of fire enclosures) |
- |
- |
|
- |
|
02 Sep, 2028 |
- Included w.e.f 31.12.2025
Exclusion Cl 1.5 (Components)
2.10.11 (Tests for semiconductor devices and for cemented joints)
2.10.12 (Enclosed and sealed parts)
2.10.5.12 (Wires in wound components)
2.10.5.13 (Winding wire)
2.10.5.14 (Additional insulation in wound components)
2.10.5.4 (Opto-coupler)
2.8.2/2.8.5 (Interlock switches)
2.8.7 (Switches and Relay)
4.2.8 (Cathode Ray Tubes)
4.3.10 (Dust, powders, liquids and gases)
4.3.11 (Containers for liquids or gases)
4.3.12 (Flammable liquids)
4.3.13.2 (Ionizing radiation)
4.3.13.3/ Annex Y (Effect of UV radiation on material/Ultraviolet conditioning test)
4.3.13.4 (Human exposure to ultraviolet (UV) radiation)
4.3.13.5 (LED, laser class)
Annex CC (Evaluation of integrated circuit (IC) current limiters)
Annex K (Thermal Control)
Annex Q (Voltage Dependent Resistors)
Annex U (Insulating winding wires for use without interleaved insulation) |
| 11 |
IS/IEC 62368 : Part 1 (2023) |
Audio Video Information and Communication Technology Equipment - Part 1: Safety Requirements (Second Revision) |
-- |
60000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl-4.1(General- materials, components) |
- |
100 |
|
N/A |
| Cl-4.2(Energy source classifications) |
- |
100 |
|
N/A |
| Cl-4.3(Protection against energy sources) |
- |
100 |
|
N/A |
| Cl-4.4(Safeguards) |
- |
100 |
|
N/A |
| Cl-4.5(Explosion) |
- |
100 |
|
N/A |
| Cl-4.6(Fixing of conductors and conductive parts) |
- |
200 |
|
N/A |
| Cl-4.7(Equipment for direct insertion into mains socket-outlets) |
- |
300 |
|
N/A |
| Cl-4.8(Equipment containing coin or button cell batteries) |
- |
200 |
|
N/A |
| Cl-4.9(Likelihood of fire or shock due to entry of conductive objects) |
- |
500 |
|
N/A |
| Cl-4.10(Components requirements) |
- |
200 |
|
N/A |
| Cl-5.1(General- Electrically-caused injury) |
- |
200 |
|
N/A |
| Cl-5.2(Classification and limits of electrical energy sources) |
- |
100 |
|
N/A |
| Cl-5.3(Protection against electrical energy sources) |
- |
1000 |
|
N/A |
| Cl-5.4(Insulation materials and requirements) |
- |
100 |
|
N/A |
| Cl-5.5(Components as safeguards) |
- |
200 |
|
N/A |
| Cl-5.6(Protective conductor) |
- |
200 |
|
N/A |
| Cl-5.7(Prospective touch voltage, touch current and protective conductor current) |
- |
300 |
|
N/A |
| Cl-5.8(Backfeed safeguard in battery backed up supplies) |
- |
200 |
|
N/A |
| Cl-6.1(General- Electrically-caused fire) |
- |
200 |
|
N/A |
| Cl-6.2(Classification of power sources and potential ignition sources) |
- |
500 |
|
N/A |
| Cl-6.3(Safeguards against fire under normal operating conditions and abnormal operating conditions) |
- |
1000 |
|
N/A |
| Cl-6.4(Safeguards against fire under single fault conditions) |
- |
200 |
|
N/A |
| Cl-6.5(Internal and external wiring) |
- |
1000 |
|
N/A |
| Cl-7.1(General- Injury caused by hazardous substances) |
- |
200 |
|
N/A |
| Cl-7.2(Reduction of exposure to hazardous substances) |
- |
200 |
|
N/A |
| Cl-7.3(Ozone exposure) |
- |
1000 |
|
N/A |
| Cl-7.4(Use of personal safeguards or personal protective equipment (PPE) |
- |
300 |
|
N/A |
| Cl-7.5(Use of instructional safeguards and instructions) |
- |
1000 |
|
N/A |
| Cl-8.1(General- Mechanically-caused injury) |
- |
1000 |
|
N/A |
| Cl-8.2(Mechanical energy source classifications) |
- |
200 |
|
N/A |
| Cl-8.3(Safeguards against mechanical energy sources) |
- |
300 |
|
N/A |
| Cl-8.4(Safeguards against parts with sharp edges and corners) |
- |
1000 |
|
N/A |
| Cl-8.5(Safeguards against moving parts) |
- |
1000 |
|
N/A |
| Cl-8.6(Stability of equipment) |
- |
1000 |
|
N/A |
| Cl-8.7(Equipment mounted to a wall, ceiling or other structure) |
- |
1000 |
|
N/A |
| Cl-8.8(Handle strength) |
- |
1000 |
|
N/A |
| Cl-8.9(Wheels or casters attachment requirements) |
- |
300 |
|
N/A |
| Cl-8.10(Carts, stands, and similar carriers) |
- |
200 |
|
N/A |
| Cl-8.11(Mounting means for slide-rail mounted equipment (SRME)) |
- |
300 |
|
N/A |
| Cl-9.1(General-Thermal burn injury) |
- |
200 |
|
N/A |
| Cl-9.2(Thermal energy source classifications) |
- |
1000 |
|
N/A |
| Cl-9.3(Touch temperature limits) |
- |
1000 |
|
N/A |
| Cl-9.4(Safeguards against thermal energy sources) |
- |
300 |
|
N/A |
| Cl-9.5(Requirements for safeguards) |
- |
200 |
|
N/A |
| Cl-9.6(Requirements for wireless power transmitters) |
- |
300 |
|
N/A |
| Cl-10.1(General-Radiation) |
- |
0 |
|
N/A |
| Cl-10.2(Radiation energy source classifications) |
- |
0 |
|
N/A |
| Cl-10.3(Safeguards against laser radiation) |
- |
0 |
|
N/A |
| Cl-10.4("Safeguards against optical radiation from lamps and lamp systems
(including LED types)") |
- |
0 |
|
N/A |
| Cl-10.5(Safeguards against X-radiation) |
- |
0 |
|
N/A |
| Cl-10.6(Safeguards against acoustic energy sources) |
- |
0 |
|
N/A |
| Annex A(Examples of equipment within the scope of this document) |
- |
0 |
|
N/A |
| Annex B(General- Normal operating condition tests, abnormal operating condition tests and single fault condition tests) |
- |
500 |
|
N/A |
| Annex B-2(Normal operating conditions) |
- |
1000 |
|
N/A |
| Annex B-3(Simulated abnormal operating conditions) |
- |
1000 |
|
N/A |
| Annex B-4(Simulated single fault conditions) |
- |
1000 |
|
N/A |
| Annex C-1(Protection of materials in equipment from UV radiation) |
- |
0 |
|
N/A |
| Annex C-2(UV light conditioning test) |
- |
0 |
|
N/A |
| Annex D-1(Impulse test generators) |
- |
1000 |
|
N/A |
| Annex D-2(Antenna interface test generator) |
- |
1000 |
|
N/A |
| Annex D-3(Electronic pulse generator) |
- |
1000 |
|
N/A |
| Annex E-1(Electrical energy source classification for audio signals) |
- |
500 |
|
N/A |
| Annex E-2(Audio signals used during test) |
- |
500 |
|
N/A |
| Annex E-3(Operating conditions of equipment containing an audio amplifier) |
- |
500 |
|
N/A |
| Annex F-1(General-Equipment markings, instructions, and instructional safeguards) |
- |
500 |
|
N/A |
| Annex F-2(Letter symbols and graphical symbols) |
- |
500 |
|
N/A |
| Annex F-3(Equipment markings) |
- |
500 |
|
N/A |
| Annex F-4(Instructions) |
- |
500 |
|
N/A |
| Annex F-5(Instructional safeguards) |
- |
500 |
|
N/A |
| Annex G-1(Switches) |
- |
0 |
|
N/A |
| Annex G-2(Relays) |
- |
0 |
|
N/A |
| Annex G-3(Protective devices) |
- |
0 |
|
N/A |
| Annex G-4(Connectors) |
- |
0 |
|
N/A |
| Annex G-5(Wound components) |
- |
500 |
|
N/A |
| Annex G-6(Wire insulation) |
- |
500 |
|
N/A |
| Annex G-7(Mains power supply cords and interconnection cables) |
- |
500 |
|
N/A |
| Annex G-8(Varistors) |
- |
0 |
|
N/A |
| Annex G-9(Integrated circuit (IC) current limiters) |
- |
0 |
|
N/A |
| Annex G-10(Resistors) |
- |
500 |
|
N/A |
| Annex G-11(Capacitors and RC units) |
- |
0 |
|
N/A |
| Annex G-12(Optocouplers) |
- |
0 |
|
N/A |
| Annex G-13(Printed boards) |
- |
500 |
|
N/A |
| Annex G-14(Coatings on component terminals) |
- |
500 |
|
N/A |
| Annex G-15(Pressurized liquid filled components or LFC assemblies) |
- |
500 |
|
N/A |
| Annex G-16(IC that includes a capacitor discharge function (ICX)) |
- |
500 |
|
N/A |
| Annex H-1(General- Criteria for telephone ringing signals) |
- |
1000 |
|
N/A |
| Annex H-2(Method A) |
- |
1000 |
|
N/A |
| Annex H-3(Method B) |
- |
1000 |
|
N/A |
| Annex I(Overvoltage categories (see IEC 60364-4-44)) |
- |
1000 |
|
N/A |
| Annex J-1(General-Insulated winding wires for use without interleaved insulation) |
- |
1000 |
|
N/A |
| Annex J-2(Type tests) |
- |
500 |
|
N/A |
| Annex J-3(Testing during manufacturing) |
- |
500 |
|
N/A |
| Annex K-1(General- Safety interlocks) |
- |
0 |
|
N/A |
| Annex K-2(Components of the safety interlock safeguard mechanism) |
- |
0 |
|
N/A |
| Annex K-3(Inadvertent change of operating mode) |
- |
0 |
|
N/A |
| Annex K-4(Interlock safeguard override) |
- |
0 |
|
N/A |
| Annex K-5(Fail-safe) |
- |
0 |
|
N/A |
| Annex K-6(Mechanically operated safety interlocks) |
- |
0 |
|
N/A |
| Annex K-7(Interlock circuit isolation) |
- |
0 |
|
N/A |
| Annex L-1(General requirements) |
- |
500 |
|
N/A |
| Annex L-2(Permanently connected equipment) |
- |
500 |
|
N/A |
| Annex L-3() |
- |
500 |
|
N/A |
| Annex L-4(Single-phase equipment) |
- |
500 |
|
N/A |
| Annex L-5(Three-phase equipment) |
- |
500 |
|
N/A |
| Annex L-6(Switches as disconnect devices) |
- |
500 |
|
N/A |
| Annex L-7(Plugs as disconnect devices) |
- |
500 |
|
N/A |
| Annex L-8(Multiple power sources) |
- |
500 |
|
N/A |
| Annex L-9(Compliance criteria) |
- |
500 |
|
N/A |
| Annex M-1(General requirements) |
- |
500 |
|
N/A |
| Annex M-2(Safety of batteries and their cells) |
- |
500 |
|
N/A |
| Annex M-3(Protection circuits for batteries provided within the equipment) |
- |
500 |
|
N/A |
| Annex M-4(Additional safeguards for equipment containing a secondary lithium battery) |
- |
500 |
|
N/A |
| Annex M-5(Risk of burn due to short-circuit during carrying) |
- |
500 |
|
N/A |
| Annex M-6(Safeguards against short-circuits) |
- |
500 |
|
N/A |
| Annex M-7(Risk of explosion from lead acid and NiCd batteries) |
- |
0 |
|
N/A |
| Annex M-8("Protection against internal ignition from external spark sources of
rechargeable batteries with aqueous electrolyte") |
- |
0 |
|
N/A |
| Annex M-9(Preventing electrolyte spillage) |
- |
1000 |
|
N/A |
| Annex M-10(Instructions to prevent reasonably foreseeable misuse) |
- |
500 |
|
N/A |
| Annex N(Electrochemical potentials (V)) |
- |
500 |
|
N/A |
| Annex O(Measurement of creepage distances and clearances) |
- |
400 |
|
N/A |
| Annex P-1(General-Safeguards against conductive objects) |
- |
500 |
|
N/A |
| Annex P-2(Safeguards against entry or consequences of entry of a foreign object) |
- |
500 |
|
N/A |
| Annex P-3(Safeguards against spillage of internal liquids) |
- |
500 |
|
N/A |
| Annex P-4(Metallized coatings and adhesives securing parts) |
- |
500 |
|
N/A |
| Annex Q-1(Limited power source) |
- |
500 |
|
N/A |
| Annex Q-2(Test for external circuits – paired conductor cable) |
- |
500 |
|
N/A |
| Annex R(Limited short-circuit test) |
- |
0 |
|
N/A |
| Annex S-1(Flammability test for fire enclosure and fire barrier materials of equipment where the steady state power does not exceed 4 000 W) |
- |
500 |
|
N/A |
| Annex S-2(Flammability test for fire enclosure and fire barrier integrity) |
- |
500 |
|
N/A |
| Annex S-3(Flammability tests for the bottom of a fire enclosure) |
- |
0 |
|
N/A |
| Annex S-4(Flammability classification of materials) |
- |
500 |
|
N/A |
| Annex S-5(Flammability test for fire enclosure materials of equipment with a steady state power exceeding 4 000 W) |
- |
500 |
|
N/A |
| Annex S-6(Grille covering material, cloth, and reticulated foam) |
- |
0 |
|
N/A |
| Annex T-1(General-Mechanical strength tests) |
- |
500 |
|
N/A |
| Annex T-2(Steady force test, 10 N) |
- |
250 |
|
N/A |
| Annex T-3(Steady force test, 30 N) |
- |
250 |
|
N/A |
| Annex T-4(Steady force test, 100 N) |
- |
250 |
|
N/A |
| Annex T-5(Steady force test, 250 N) |
- |
250 |
|
N/A |
| Annex T-6(Enclosure impact test) |
- |
250 |
|
N/A |
| Annex T-7(Drop test) |
- |
250 |
|
N/A |
| Annex T-8(Stress relief test) |
- |
250 |
|
N/A |
| Annex T-9(Glass impact test) |
- |
250 |
|
N/A |
| Annex T-10(Glass fragmentation test) |
- |
250 |
|
N/A |
| Annex T-11(Test for telescoping or rod antennas) |
- |
250 |
|
N/A |
| Annex U("Mechanical strength of CRTs and protection against the effects
of implosion") |
- |
0 |
|
N/A |
| Annex V-1(Accessible parts of equipment) |
- |
250 |
|
N/A |
| Annex V-2(Accessible part criterion) |
- |
250 |
|
N/A |
| Annex W(Comparison of terms introduced in this document) |
- |
250 |
|
N/A |
| Annex X("Alternative method for determining clearances for insulation in
circuits connected to an AC mains not exceeding 420 V peak (300 V RMS)") |
- |
250 |
|
N/A |
| Annex Y-1(General- Construction requirements for outdoor enclosures) |
- |
250 |
|
N/A |
| Annex Y-2(Resistance to UV radiation) |
- |
0 |
|
N/A |
| Annex Y-3(Resistance to corrosion) |
- |
250 |
|
N/A |
| Annex Y-4(Gaskets) |
- |
0 |
|
N/A |
| Annex Y-5(Protection of equipment within an outdoor enclosure) |
- |
250 |
|
N/A |
| Annex Y-6(Mechanical strength of enclosures) |
- |
250 |
|
N/A |
| Cl-4.1(General- materials, components) |
- |
0 |
|
N/A |
| Cl-4.2(Energy source classifications) |
- |
0 |
|
N/A |
| Cl-4.3(Protection against energy sources) |
- |
0 |
|
N/A |
| Cl-4.4(Safeguards) |
- |
0 |
|
N/A |
| Cl-4.5(Explosion) |
- |
0 |
|
N/A |
| Cl-4.6(Fixing of conductors and conductive parts) |
- |
0 |
|
N/A |
| Cl-4.7(Equipment for direct insertion into mains socket-outlets) |
- |
0 |
|
N/A |
| Cl-4.8(Equipment containing coin or button cell batteries) |
- |
0 |
|
N/A |
| Cl-4.9(Likelihood of fire or shock due to entry of conductive objects) |
- |
0 |
|
N/A |
| Cl-4.10(Components requirements) |
- |
0 |
|
N/A |
| Cl-5.1(General- Electrically-caused injury) |
- |
0 |
|
N/A |
| Cl-5.2(Classification and limits of electrical energy sources) |
- |
0 |
|
N/A |
| Cl-5.3(Protection against electrical energy sources) |
- |
0 |
|
N/A |
| Cl-5.4(Insulation materials and requirements) |
- |
0 |
|
N/A |
| Cl-5.5(Components as safeguards) |
- |
0 |
|
N/A |
| Cl-5.6(Protective conductor) |
- |
0 |
|
N/A |
| Cl-5.7(Prospective touch voltage, touch current and protective conductor current) |
- |
0 |
|
N/A |
| Cl-5.8(Backfeed safeguard in battery backed up supplies) |
- |
0 |
|
N/A |
| Cl-6.1(General- Electrically-caused fire) |
- |
0 |
|
N/A |
| Cl-6.2(Classification of power sources and potential ignition sources) |
- |
0 |
|
N/A |
| Cl-6.3(Safeguards against fire under normal operating conditions and abnormal operating conditions) |
- |
0 |
|
N/A |
| Cl-6.4(Safeguards against fire under single fault conditions) |
- |
0 |
|
N/A |
| Cl-6.5(Internal and external wiring) |
- |
0 |
|
N/A |
| Cl-7.1(General- Injury caused by hazardous substances) |
- |
0 |
|
N/A |
| Cl-7.2(Reduction of exposure to hazardous substances) |
- |
0 |
|
N/A |
| Cl-7.3(Ozone exposure) |
- |
0 |
|
N/A |
| Cl-7.4(Use of personal safeguards or personal protective equipment (PPE) |
- |
0 |
|
N/A |
| Cl-7.5(Use of instructional safeguards and instructions) |
- |
0 |
|
N/A |
| Cl-8.1(General- Mechanically-caused injury) |
- |
0 |
|
N/A |
| Cl-8.2(Mechanical energy source classifications) |
- |
0 |
|
N/A |
| Cl-8.3(Safeguards against mechanical energy sources) |
- |
0 |
|
N/A |
| Cl-8.4(Safeguards against parts with sharp edges and corners) |
- |
0 |
|
N/A |
| Cl-8.5(Safeguards against moving parts) |
- |
0 |
|
N/A |
| Cl-8.6(Stability of equipment) |
- |
0 |
|
N/A |
| Cl-8.7(Equipment mounted to a wall, ceiling or other structure) |
- |
0 |
|
N/A |
| Cl-8.8(Handle strength) |
- |
0 |
|
N/A |
| Cl-8.9(Wheels or casters attachment requirements) |
- |
0 |
|
N/A |
| Cl-8.10(Carts, stands, and similar carriers) |
- |
0 |
|
N/A |
| Cl-8.11(Mounting means for slide-rail mounted equipment (SRME)) |
- |
0 |
|
N/A |
| Cl-9.1(General-Thermal burn injury) |
- |
0 |
|
N/A |
| Cl-9.2(Thermal energy source classifications) |
- |
0 |
|
N/A |
| Cl-9.3(Touch temperature limits) |
- |
0 |
|
N/A |
| Cl-9.4(Safeguards against thermal energy sources) |
- |
0 |
|
N/A |
| Cl-9.5(Requirements for safeguards) |
- |
0 |
|
N/A |
| Cl-9.6(Requirements for wireless power transmitters) |
- |
0 |
|
N/A |
| Cl-10.1(General-Radiation) |
- |
0 |
|
N/A |
| Cl-10.2(Radiation energy source classifications) |
- |
0 |
|
N/A |
| Cl-10.3(Safeguards against laser radiation) |
- |
0 |
|
N/A |
| Cl-10.4("Safeguards against optical radiation from lamps and lamp systems
(including LED types)") |
- |
0 |
|
N/A |
| Cl-10.5(Safeguards against X-radiation) |
- |
0 |
|
N/A |
| Cl-10.6(Safeguards against acoustic energy sources) |
- |
0 |
|
N/A |
| Annex A(Examples of equipment within the scope of this document) |
- |
0 |
|
N/A |
| Annex B(General- Normal operating condition tests, abnormal operating condition tests and single fault condition tests) |
- |
0 |
|
N/A |
| Annex B-2(Normal operating conditions) |
- |
0 |
|
N/A |
| Annex B-3(Simulated abnormal operating conditions) |
- |
0 |
|
N/A |
| Annex B-4(Simulated single fault conditions) |
- |
0 |
|
N/A |
| Annex C-1(Protection of materials in equipment from UV radiation) |
- |
0 |
|
N/A |
| Annex C-2(UV light conditioning test) |
- |
0 |
|
N/A |
| Annex D-1(Impulse test generators) |
- |
0 |
|
N/A |
| Annex D-2(Antenna interface test generator) |
- |
0 |
|
N/A |
| Annex D-3(Electronic pulse generator) |
- |
0 |
|
N/A |
| Annex E-1(Electrical energy source classification for audio signals) |
- |
0 |
|
N/A |
| Annex E-2(Audio signals used during test) |
- |
0 |
|
N/A |
| Annex E-3(Operating conditions of equipment containing an audio amplifier) |
- |
0 |
|
N/A |
| Annex F-1(General-Equipment markings, instructions, and instructional safeguards) |
- |
0 |
|
N/A |
| Annex F-2(Letter symbols and graphical symbols) |
- |
0 |
|
N/A |
| Annex F-3(Equipment markings) |
- |
0 |
|
N/A |
| Annex F-4(Instructions) |
- |
0 |
|
N/A |
| Annex F-5(Instructional safeguards) |
- |
0 |
|
N/A |
| Annex G-1(Switches) |
- |
0 |
|
N/A |
| Annex G-2(Relays) |
- |
0 |
|
N/A |
| Annex G-3(Protective devices) |
- |
0 |
|
N/A |
| Annex G-4(Connectors) |
- |
0 |
|
N/A |
| Annex G-5(Wound components) |
- |
0 |
|
N/A |
| Annex G-6(Wire insulation) |
- |
0 |
|
N/A |
| Annex G-7(Mains power supply cords and interconnection cables) |
- |
0 |
|
N/A |
| Annex G-8(Varistors) |
- |
0 |
|
N/A |
| Annex G-9(Integrated circuit (IC) current limiters) |
- |
0 |
|
N/A |
| Annex G-10(Resistors) |
- |
0 |
|
N/A |
| Annex G-11(Capacitors and RC units) |
- |
0 |
|
N/A |
| Annex G-12(Optocouplers) |
- |
0 |
|
N/A |
| Annex G-13(Printed boards) |
- |
0 |
|
N/A |
| Annex G-14(Coatings on component terminals) |
- |
0 |
|
N/A |
| Annex G-15(Pressurized liquid filled components or LFC assemblies) |
- |
0 |
|
N/A |
| Annex G-16(IC that includes a capacitor discharge function (ICX)) |
- |
0 |
|
N/A |
| Annex H-1(General- Criteria for telephone ringing signals) |
- |
0 |
|
N/A |
| Annex H-2(Method A) |
- |
0 |
|
N/A |
| Annex H-3(Method B) |
- |
0 |
|
N/A |
| Annex I(Overvoltage categories (see IEC 60364-4-44)) |
- |
0 |
|
N/A |
| Annex J-1(General-Insulated winding wires for use without interleaved insulation) |
- |
0 |
|
N/A |
| Annex J-2(Type tests) |
- |
0 |
|
N/A |
| Annex J-3(Testing during manufacturing) |
- |
0 |
|
N/A |
| Annex K-1(General- Safety interlocks) |
- |
0 |
|
N/A |
| Annex K-2(Components of the safety interlock safeguard mechanism) |
- |
0 |
|
N/A |
| Annex K-3(Inadvertent change of operating mode) |
- |
0 |
|
N/A |
| Annex K-4(Interlock safeguard override) |
- |
0 |
|
N/A |
| Annex K-5(Fail-safe) |
- |
0 |
|
N/A |
| Annex K-6(Mechanically operated safety interlocks) |
- |
0 |
|
N/A |
| Annex K-7(Interlock circuit isolation) |
- |
0 |
|
N/A |
| Annex L-1(General requirements) |
- |
0 |
|
N/A |
| Annex L-2(Permanently connected equipment) |
- |
0 |
|
N/A |
| Annex L-3() |
- |
0 |
|
N/A |
| Annex L-4(Single-phase equipment) |
- |
0 |
|
N/A |
| Annex L-5(Three-phase equipment) |
- |
0 |
|
N/A |
| Annex L-6(Switches as disconnect devices) |
- |
0 |
|
N/A |
| Annex L-7(Plugs as disconnect devices) |
- |
0 |
|
N/A |
| Annex L-8(Multiple power sources) |
- |
0 |
|
N/A |
| Annex L-9(Compliance criteria) |
- |
0 |
|
N/A |
| Annex M-1(General requirements) |
- |
0 |
|
N/A |
| Annex M-2(Safety of batteries and their cells) |
- |
0 |
|
N/A |
| Annex M-3(Protection circuits for batteries provided within the equipment) |
- |
0 |
|
N/A |
| Annex M-4(Additional safeguards for equipment containing a secondary lithium battery) |
- |
0 |
|
N/A |
| Annex M-5(Risk of burn due to short-circuit during carrying) |
- |
0 |
|
N/A |
| Annex M-6(Safeguards against short-circuits) |
- |
0 |
|
N/A |
| Annex M-7(Risk of explosion from lead acid and NiCd batteries) |
- |
0 |
|
N/A |
| Annex M-8("Protection against internal ignition from external spark sources of
rechargeable batteries with aqueous electrolyte") |
- |
0 |
|
N/A |
| Annex M-9(Preventing electrolyte spillage) |
- |
0 |
|
N/A |
| Annex M-10(Instructions to prevent reasonably foreseeable misuse) |
- |
0 |
|
N/A |
| Annex N(Electrochemical potentials (V)) |
- |
0 |
|
N/A |
| Annex O(Measurement of creepage distances and clearances) |
- |
0 |
|
N/A |
| Annex P-1(General-Safeguards against conductive objects) |
- |
0 |
|
N/A |
| Annex P-2(Safeguards against entry or consequences of entry of a foreign object) |
- |
0 |
|
N/A |
| Annex P-3(Safeguards against spillage of internal liquids) |
- |
0 |
|
N/A |
| Annex P-4(Metallized coatings and adhesives securing parts) |
- |
0 |
|
N/A |
| Annex Q-1(Limited power source) |
- |
0 |
|
N/A |
| Annex Q-2(Test for external circuits – paired conductor cable) |
- |
0 |
|
N/A |
| Annex R(Limited short-circuit test) |
- |
0 |
|
N/A |
| Annex S-1(Flammability test for fire enclosure and fire barrier materials of equipment where the steady state power does not exceed 4 000 W) |
- |
0 |
|
N/A |
| Annex S-2(Flammability test for fire enclosure and fire barrier integrity) |
- |
0 |
|
N/A |
| Annex S-3(Flammability tests for the bottom of a fire enclosure) |
- |
0 |
|
N/A |
| Annex S-4(Flammability classification of materials) |
- |
0 |
|
N/A |
| Annex S-5(Flammability test for fire enclosure materials of equipment with a steady state power exceeding 4 000 W) |
- |
0 |
|
N/A |
| Annex S-6(Grille covering material, cloth, and reticulated foam) |
- |
0 |
|
N/A |
| Annex T-1(General-Mechanical strength tests) |
- |
0 |
|
N/A |
| Annex T-2(Steady force test, 10 N) |
- |
0 |
|
N/A |
| Annex T-3(Steady force test, 30 N) |
- |
0 |
|
N/A |
| Annex T-4(Steady force test, 100 N) |
- |
0 |
|
N/A |
| Annex T-5(Steady force test, 250 N) |
- |
0 |
|
N/A |
| Annex T-6(Enclosure impact test) |
- |
0 |
|
N/A |
| Annex T-7(Drop test) |
- |
0 |
|
N/A |
| Annex T-8(Stress relief test) |
- |
0 |
|
N/A |
| Annex T-9(Glass impact test) |
- |
0 |
|
N/A |
| Annex T-10(Glass fragmentation test) |
- |
0 |
|
N/A |
| Annex T-11(Test for telescoping or rod antennas) |
- |
0 |
|
N/A |
| Annex U("Mechanical strength of CRTs and protection against the effects
of implosion") |
- |
0 |
|
N/A |
| Annex V-1(Accessible parts of equipment) |
- |
0 |
|
N/A |
| Annex V-2(Accessible part criterion) |
- |
0 |
|
N/A |
| Annex W(Comparison of terms introduced in this document) |
- |
0 |
|
N/A |
| Annex X("Alternative method for determining clearances for insulation in
circuits connected to an AC mains not exceeding 420 V peak (300 V RMS)") |
- |
0 |
|
N/A |
| Annex Y-1(General- Construction requirements for outdoor enclosures) |
- |
0 |
|
N/A |
| Annex Y-2(Resistance to UV radiation) |
- |
0 |
|
N/A |
| Annex Y-3(Resistance to corrosion) |
- |
0 |
|
N/A |
| Annex Y-4(Gaskets) |
- |
0 |
|
N/A |
| Annex Y-5(Protection of equipment within an outdoor enclosure) |
- |
0 |
|
N/A |
| Annex Y-6(Mechanical strength of enclosures) |
- |
0 |
|
N/A |
|
02 Sep, 2028 |
- Included w.e.f 31.12.2025
Exclusion: Annex C-1 (Protection of materials in equipment from UV radiation)
Annex C-2 (UV light conditioning test)
Annex G-1 (Switches)
Annex G-11 (Capacitors and RC units)
Annex G-12 (Optocouplers)
Annex G-2 (Relays)
Annex G-3 (Protective devices)
Annex G-4 (Connectors)
Annex G-8 (Varistors)
Annex G-9 (Integrated circuit (IC) current limiters)
Annex K-1 (General- Safety interlocks)
Annex K-2 (Components of the safety interlock safeguard mechanism)
Annex K-3 (Inadvertent change of operating mode)
Annex K-4 (Interlock safeguard override)
Annex K-5 (Fail-safe)
Annex K-6 (Mechanically operated safety interlocks)
Annex K-7 (Interlock circuit isolation)
Annex M-7 (Risk of explosion from lead acid and NiCd batteries)
Annex M-8 ("Protection against internal ignition from external spark sources of rechargeable batteries with aqueous electrolyte")
Annex R (Limited short-circuit test)
Annex S-3 (Flammability tests for the bottom of a fire enclosure)
Annex S-6 (Grille covering material, cloth, and reticulated foam)
Annex U ("Mechanical strength of CRTs and protection against the effects of implosion")
Annex Y-2 (Resistance to UV radiation)
Annex Y-4 (Gaskets)
Cl-10.1 (General-Radiation)
Cl-10.2 (Radiation energy source classifications)
Cl-10.3 (Safeguards against laser radiation)
Cl-10.4 ("Safeguards against optical radiation from lamps and lamp systems (including LED types)")
Cl-10.5 (Safeguards against X-radiation)
Cl-10.6 (Safeguards against acoustic energy sources) |
| 12 |
IS 16242 : Part 1 (2025) |
Uninterruptible power systems UPS Part 1 Safety requirements (first revision) |
-- |
95000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl-4.2(Fault and abnormal conditions) |
- |
1000 |
|
N/A |
| Cl-4.3(Short-circuit and overload protection) |
- |
500 |
|
N/A |
| Cl-4.3.101(AC input current) |
- |
500 |
|
N/A |
| Cl-4.3.102(Transformer protection) |
- |
1000 |
|
N/A |
| Cl-4.3.103(AC input short-circuit current) |
- |
500 |
|
N/A |
| Cl-4.3.104(Protection of the energy storage device) |
- |
500 |
|
N/A |
| Cl-4.3.105(Unsynchronised load transfer) |
- |
1000 |
|
N/A |
| Cl-4.4(Protection against electric shock) |
- |
1000 |
|
N/A |
| Cl-4.4.2.2.2(Selection tables for contact area and skin humidity condition) |
- |
1000 |
|
N/A |
| Cl-4.4.3.3(Protection by means of enclosures or barriers- Openings) |
- |
1000 |
|
N/A |
| Cl-4.4.7.1.1(Influencing factors) |
- |
1000 |
|
N/A |
| Cl-4.4.7.1.2(Pollution degree) |
- |
500 |
|
N/A |
| Cl-4.4.7.1.3(Overvoltage category (OVC)) |
- |
1000 |
|
N/A |
| Cl-4.4.7.7(PWB spacings for functional insulation) |
- |
1000 |
|
N/A |
| Cl-4.4.9(Capacitor discharge) |
- |
3000 |
|
N/A |
| Cl-4.5.2(Service access areas) |
- |
1000 |
|
N/A |
| Cl-4.6(Protection against fire and thermal hazards) |
- |
1000 |
|
N/A |
| Cl-4.6.2.2(Components within a circuit representing a fire hazard) |
- |
2000 |
|
N/A |
| Cl-4.6.3.1(General) |
- |
1000 |
|
N/A |
| Cl-4.6.3.2(Flammability of enclosure materials) |
- |
1000 |
|
N/A |
| Cl-4.6.3.3.2(Openings in the top and side of fire enclosures) |
- |
500 |
|
N/A |
| Cl-4.6.4.1(Temperature limits- Internal parts) |
- |
500 |
|
N/A |
| Cl- 4.6.5(Limited power sources) |
- |
3000 |
|
N/A |
| Cl-4.7(Protection against mechanical hazards) |
- |
1000 |
|
N/A |
| Clause 4(Protection against hazards) |
- |
1000 |
|
N/A |
| Cl-4.7.101(Protection in service access area) |
- |
1000 |
|
N/A |
| Clause 5(Test requirements) |
- |
1000 |
|
N/A |
| Cl-4.8 .101(Equipment with multiple sources of supply- General) |
- |
1000 |
|
N/A |
| Clause 5.2.2(Mechanical tests) |
- |
1000 |
|
N/A |
| Clause 5.2.3(Electrical tests) |
- |
1000 |
|
N/A |
| Cl-4.9(Protection against environmental stresses) |
- |
1000 |
|
N/A |
| Cl-4.10(Protection against sonic pressure hazards) |
- |
500 |
|
N/A |
| Clause 5.2.4("Abnormal operation
tests") |
- |
500 |
|
N/A |
| Cl-4.11(Wiring and connections) |
- |
500 |
|
N/A |
| Clause 5.2.5(Material tests) |
- |
1000 |
|
N/A |
| Clause 5.2.6(Environmental tests) |
- |
1000 |
|
N/A |
| Cl-4.11.101.1(Non-detachable cords- Cord guard) |
- |
1000 |
|
N/A |
| Clause 5.2.7(Hydrostatic pressure test) |
- |
2000 |
|
N/A |
| Cl-4.11.101.2(Cord anchorages and strain relief) |
- |
1000 |
|
N/A |
| Clause 6(Information and marking requirements) |
- |
2000 |
|
N/A |
| Cl-4.101.1(Emergency switching (disconnect) device) |
- |
2000 |
|
N/A |
| Clause 6.1.101(Durability) |
- |
1000 |
|
N/A |
| Cl-4.101.2(Normal disconnect devices) |
- |
1000 |
|
N/A |
| Cl-4.102.1(Stored energy source- General) |
- |
1000 |
|
N/A |
| Cl-4.102.2(Accessibility and maintainability) |
- |
2000 |
|
N/A |
| Cl-4.102.3(Distance between battery cells) |
- |
1000 |
|
N/A |
| Cl- 4.102.5(Electrolyte spillage) |
- |
1000 |
|
N/A |
| Cl- 4.102.6(Ventilation and hydrogen concentration) |
- |
2000 |
|
N/A |
| Cl- 4.102.8.1(Overcurrent and earth fault protection) |
- |
1000 |
|
N/A |
| Cl- 4.102.8.2(Location of protective devices) |
- |
2000 |
|
N/A |
| Cl-4.102.8.3(Rating of protective devices) |
- |
2000 |
|
N/A |
| Cl-4.103(UPS connection to telecommunication lines) |
- |
2000 |
|
N/A |
| Cl-5.1.5.3(Operating parameters for tests) |
- |
1000 |
|
N/A |
| Cl-5.1.7(Test overview) |
- |
1000 |
|
N/A |
| Cl-5.2.2.2(Non-accessibility test) |
- |
1000 |
|
N/A |
| Cl-5.2.2.4.4(Drop test) |
- |
1000 |
|
N/A |
| Cl-4.8.102(Backfeed protection) |
- |
3000 |
|
N/A |
| Cl- 4.102.7(Charging voltages) |
- |
1000 |
|
N/A |
| Cl-5.2.2.6.101(Wall or ceiling mounted equipment test) |
- |
2000 |
|
N/A |
| Cl-5.2.2.6.102(Rack mounted equipment test) |
- |
2000 |
|
N/A |
| Cl-5.2.2.101(Cord guard test) |
- |
1000 |
|
N/A |
| Cl-5.2.3.9(Limited power source test) |
- |
2000 |
|
N/A |
| Cl-5.2.3.10(Temperature rise test) |
- |
1000 |
|
N/A |
| Cl-5.2.3.101.1(Backfeed protection test- General) |
- |
2000 |
|
N/A |
| Cl-5.2.3.101.2(Test for pluggable UPS) |
- |
1000 |
|
N/A |
| Cl-5.2.3.101.3(Test for permanently connected UPS) |
- |
2000 |
|
N/A |
| Cl-5.2.3.101.4(Method to simulate the load-induced change of reference potential for pluggable UPS) |
- |
1000 |
|
N/A |
| Cl-5.2.3.101.5(Solid-state backfeed protection) |
- |
500 |
|
N/A |
| Cl-5.2.3.102(Input current test) |
- |
1000 |
|
N/A |
| Cl-5.2.3.103(Short-time withstand current test) |
- |
500 |
|
N/A |
| Cl-5.2.3103.3(Input port short-time withstand current rating) |
- |
500 |
|
N/A |
| Cl-5.2.3.104(Transformer protection test) |
- |
500 |
|
N/A |
| Cl- 5.2.3.105(Unsynchronised load transfer test) |
- |
500 |
|
N/A |
| Cl-5.2.4.1(Abnormal operation and simulated faults tests- General) |
- |
500 |
|
N/A |
| Cl-5.2.6.4(Vibration test) |
- |
2000 |
|
N/A |
| Cl-5.2.6.5(Salt mist test) |
- |
1000 |
|
N/A |
| Cl-5.2.6.6(Dust and sand test) |
- |
1000 |
|
N/A |
| Cl-6(Information and marking requirements) |
- |
500 |
|
N/A |
|
02 Sep, 2028 |
- Included w.e.f 07.11.2025 |
| 13 |
IS 302 : Part 2 : Sec 9 (2009) |
Safety of household and similar electrical appliances: Part 2 particular requirements: Sec 9 toasters, grills, roasters and similar appliances (First Revision) |
-- |
8500 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl.32(Verification) |
- |
0 |
|
N/A |
| Cl.31(Verification) |
- |
0 |
|
N/A |
| Cl.30(Verification) |
- |
0 |
|
N/A |
| CL.29(Verification) |
- |
0 |
|
N/A |
| Cl.28(Verification) |
- |
0 |
|
N/A |
| Cl.27(Verification) |
- |
0 |
|
N/A |
| Cl.26(Verification) |
- |
0 |
|
N/A |
| Cl.25(Verification) |
- |
0 |
|
N/A |
| Cl.24(Verification) |
- |
0 |
|
N/A |
| Cl.23(Verification) |
- |
0 |
|
N/A |
| Cl.22(Verification) |
- |
0 |
|
N/A |
| Cl.21(Verification) |
- |
0 |
|
N/A |
| Cl.20(Verification) |
- |
0 |
|
N/A |
| Cl.19(Verification) |
- |
0 |
|
N/A |
| Cl. 16(Verification) |
- |
0 |
|
N/A |
| Cl.15.1(Moisture Resistance) |
- |
0 |
|
N/A |
| Cl.14(Verification) |
- |
0 |
|
N/A |
| Cl.13(Verification) |
- |
0 |
|
N/A |
| Cl.11(Verification) |
- |
0 |
|
N/A |
| Cl.10(Verification) |
- |
0 |
|
N/A |
| Cl.8(Verification) |
- |
0 |
|
N/A |
| Cl. 7(Verification) |
- |
0 |
|
N/A |
| Cl. 6(Classification- IS 302-1) |
- |
0 |
|
N/A |
| Cl. 32
IS 302-2-9(Radiation, Toxicity and similar hazards) |
- |
0 |
|
N/A |
| Cl. 31
IS 302-2-9(Resistance To Rusting ) |
- |
500 |
|
N/A |
| Cl. 30
IS 302-2-9(Resistance To Heat, Fire And Tracking) |
- |
500 |
|
N/A |
| Cl. 29
IS 302-2-9(Creepage Distances, Clearances And Distances Through Insulation) |
- |
500 |
|
N/A |
| Cl. 28
IS 302-2-9(Screws and Connections) |
- |
500 |
|
N/A |
| Cl. 27
IS 302-2-9(Provision For Earthing ) |
- |
250 |
|
N/A |
| Cl. 26
IS 302-2-9(Terminal For External Conductors ) |
- |
250 |
|
N/A |
| Cl. 25
IS 302-2-9(Supply Connections and External Flexible Cables and Cords ) |
- |
250 |
|
N/A |
| Cl. 24
IS 302-2-9(Components) |
- |
250 |
|
N/A |
| Cl. 23
IS 302-2-9(Internal Wiring) |
- |
250 |
|
N/A |
| Cl. 22
IS 302-2-9(Construction ) |
- |
250 |
|
N/A |
| Cl. 21
IS 302-2-9(Mechanical Strength) |
- |
250 |
|
N/A |
| Cl. 20
IS 302-2-9(Stability and mechanical Hazards) |
- |
250 |
|
N/A |
| Cl. 19
IS 302-2-9(Abnormal Operation ) |
- |
250 |
|
N/A |
| Cl. 18
IS 302-2-9(Endurance) |
- |
0 |
|
N/A |
| Cl. 17
IS 302-2-9(Overload protection of transformers and associated circuits.) |
- |
250 |
|
N/A |
| Cl. 16
IS 302-2-9(Leakage Current and Electric strength ) |
- |
250 |
|
N/A |
| Cl. 15
IS 302-2-9(Moisture Resistance) |
- |
250 |
|
N/A |
| Cl. 14
IS 302-2-9(Transient overvoltage) |
- |
250 |
|
N/A |
| Cl. 13.3 IS 302-2-9(Leakage Current & Electric Strength at Operating Temperature) |
- |
250 |
|
N/A |
| Cl. 11
IS 302-2-9(Heating) |
- |
250 |
|
N/A |
| Cl. 10
IS 302-2-9(Power Input and Current ) |
- |
250 |
|
N/A |
| Cl. 9
IS 302-2-9(Starting of motor operated appliances) |
- |
0 |
|
N/A |
| Cl. 8
IS 302-2-9(Protection against access to live parts) |
- |
250 |
|
N/A |
| Cl. 7
IS 302-2-9(Marking and Instruction) |
- |
100 |
|
N/A |
| Cl. 6 IS 302-2-9(Classification- IS 302-1) |
- |
100 |
|
N/A |
| 32(Radiation, toxicity and similar hazards) |
- |
0 |
|
N/A |
| 31(Resistance to rusting) |
- |
0 |
|
N/A |
| 31(Resistance to rusting) |
- |
0 |
|
N/A |
| 30.2.4(Resistance to heat and fire) |
- |
0 |
|
N/A |
| 30.2(Resistance to heat and fire) |
- |
0 |
|
N/A |
| 30.1(Resistance to heat and fire) |
- |
0 |
|
N/A |
| 29.3(Clearances, creepage distances and solid insulation) |
- |
0 |
|
N/A |
| 29.2(Clearances, creepage distances and solid insulation) |
- |
0 |
|
N/A |
| 29.2(Clearances, creepage distances and solid insulation) |
- |
0 |
|
N/A |
| 29.1, Table No.- 16, Table No.- 17 & Table No.18(Clearances, creepage distances and solid insulation) |
- |
0 |
|
N/A |
| 29.1, Table No.- 16, Table No.- 17 & Table No.18(Clearances, creepage distances and solid insulation) |
- |
0 |
|
N/A |
| 28.2 to 28.4(Screws and connections) |
- |
0 |
|
N/A |
| 28.1, Table No.-14(Screws and connections) |
- |
0 |
|
N/A |
| 27.6(Provision for earthing) |
- |
0 |
|
N/A |
| 27.5(Provision for earthing) |
- |
0 |
|
N/A |
| 27.1 to 27.4(Provision for earthing) |
- |
0 |
|
N/A |
| 26.10 & 26.11(Terminals for external conductors) |
- |
0 |
|
N/A |
| 26.9(Terminals for external conductors) |
- |
0 |
|
N/A |
| 26.1 to 26.8(Terminals for external conductors) |
- |
0 |
|
N/A |
| 25.16 to 25.25(Supply connection and external flexible cords) |
- |
0 |
|
N/A |
| 25.15(Supply connection and external flexible cords) |
- |
0 |
|
N/A |
| 25.14(Supply connection and external flexible cords) |
- |
0 |
|
N/A |
| 25.14(Supply connection and external flexible cords) |
- |
0 |
|
N/A |
| 25.9 to 25.13(Supply connection and external flexible cords) |
- |
0 |
|
N/A |
| 25.8, Table No.-11(Supply connection and external flexible cords) |
- |
0 |
|
N/A |
| 25.5 to 25.7(Supply connection and external flexible cords) |
- |
0 |
|
N/A |
| 25.4(Supply connection and external flexible cords) |
- |
0 |
|
N/A |
| 25.3(Supply connection and external flexible cords) |
- |
0 |
|
N/A |
| 25.2(Supply connection and external flexible cords) |
- |
0 |
|
N/A |
| 25.1(Supply connection and external flexible cords) |
- |
0 |
|
N/A |
| 24.101(Components) |
- |
0 |
|
N/A |
| 24.101(Components) |
- |
0 |
|
N/A |
| 24.2 to 24.6(Components) |
- |
0 |
|
N/A |
| 24.1(Components) |
- |
0 |
|
N/A |
| 23.6 to 23.10(Internal wiring) |
- |
0 |
|
N/A |
| 23.5(Internal wiring) |
- |
0 |
|
N/A |
| 23.4(Internal wiring) |
- |
0 |
|
N/A |
| 23.3(Internal wiring) |
- |
0 |
|
N/A |
| 23.1 & 23.2(Internal wiring) |
- |
0 |
|
N/A |
| 22.111(Constructions) |
- |
0 |
|
N/A |
| 22.111(Constructions) |
- |
0 |
|
N/A |
| 22.11o(Constructions) |
- |
0 |
|
N/A |
| 22.109(Constructions) |
- |
0 |
|
N/A |
| 22.108(Constructions) |
- |
0 |
|
N/A |
| 22.101 to 22.107(Constructions) |
- |
0 |
|
N/A |
| 22.13 to 22.48(Constructions) |
- |
0 |
|
N/A |
| 22.12(Constructions) |
- |
0 |
|
N/A |
| 22.11(Constructions) |
- |
0 |
|
N/A |
| 22.11(Constructions) |
- |
0 |
|
N/A |
| 22.7 to 22.10(Constructions) |
- |
0 |
|
N/A |
| 22.6(Constructions) |
- |
0 |
|
N/A |
| 22.5(Constructions) |
- |
0 |
|
N/A |
| 22.4(Constructions) |
- |
0 |
|
N/A |
| 22.3(Constructions) |
- |
0 |
|
N/A |
| 22.2(Constructions) |
- |
0 |
|
N/A |
| 22.1(Constructions) |
- |
0 |
|
N/A |
| 21.101(MECHANICAL STRENGTH) |
- |
0 |
|
N/A |
| 21.101(MECHANICAL STRENGTH) |
- |
0 |
|
N/A |
| 21.2(MECHANICAL STRENGTH) |
- |
0 |
|
N/A |
| 21.1(MECHANICAL STRENGTH) |
- |
0 |
|
N/A |
| 20.2(Stability and mechanical hazards) |
- |
0 |
|
N/A |
| 20.1(Stability and mechanical hazards) |
- |
0 |
|
N/A |
| 19.104(ABNORMAL OPERATION) |
- |
0 |
|
N/A |
| 19.103(ABNORMAL OPERATION) |
- |
0 |
|
N/A |
| 19.102(ABNORMAL OPERATION) |
- |
0 |
|
N/A |
| 19.101(ABNORMAL OPERATION) |
- |
0 |
|
N/A |
| 19.1 to 19.13, Table No. - 9(ABNORMAL OPERATION) |
- |
0 |
|
N/A |
| 17(Overload protection of transformers and associated circuits) |
- |
0 |
|
N/A |
| 16.3(Insulation resistance test) |
- |
0 |
|
N/A |
| 16.3(Electric strength test) |
- |
0 |
|
N/A |
| 16.1 & 16.2(Leakage current test) |
- |
0 |
|
N/A |
| 15.3(Moisture resistance) |
- |
0 |
|
N/A |
| 15.3(Moisture resistance) |
- |
0 |
|
N/A |
| 15.3(Moisture resistance) |
- |
0 |
|
N/A |
| 15.2(Moisture resistance) |
- |
0 |
|
N/A |
| 15.2(Moisture resistance) |
- |
0 |
|
N/A |
| 15.2(Moisture resistance) |
- |
0 |
|
N/A |
| 15.2(Moisture resistance) |
- |
0 |
|
N/A |
| 15.1(Moisture resistance) |
- |
0 |
|
N/A |
| 14, Table No.- 6 & Table No.-16(Transient over voltages) |
- |
0 |
|
N/A |
| 13.3 and Table No.- 4(Electric strength test) |
- |
0 |
|
N/A |
| 13.1, 13.2(Leakage current test) |
- |
0 |
|
N/A |
| 13.1, 13.2(Leakage current test) |
- |
0 |
|
N/A |
| 11.101(Heating) |
- |
0 |
|
N/A |
| 11.1 to 11.8, Table No.-3(Heating) |
- |
0 |
|
N/A |
| 10.1 & 10.2 -Table No. 1, Table No. 2(Power Input and Current) |
- |
0 |
|
N/A |
| 8.1.5(Protection against access to live parts) |
- |
0 |
|
N/A |
| 8.1.4(Protection against access to live parts) |
- |
0 |
|
N/A |
| 8.1.3(Protection against access to live parts) |
- |
0 |
|
N/A |
| 8.1.2(Protection against access to live parts) |
- |
0 |
|
N/A |
| 8.1, 8.1.1 & 8.2(Protection against access to live parts) |
- |
0 |
|
N/A |
| 7.14(Legibility & Durability of Markings test) |
- |
0 |
|
N/A |
| 7.1 to 7.13, 7.15, 7.16(Marking) |
- |
0 |
|
N/A |
| 32(Radiation, toxicity and similar hazards) |
- |
0 |
|
N/A |
| 31(Resistance to rusting) |
- |
100 |
|
N/A |
| 31(Resistance to rusting) |
- |
100 |
|
N/A |
| 30.2.4(Resistance to heat and fire) |
- |
100 |
|
N/A |
| 30.2(Resistance to heat and fire) |
- |
0 |
|
N/A |
| 30.1(Resistance to heat and fire) |
- |
0 |
|
N/A |
| 29.3(Clearances, creepage distances and solid insulation) |
- |
0 |
|
N/A |
| 29.2(Clearances, creepage distances and solid insulation) |
- |
0 |
|
N/A |
| 29.2(Clearances, creepage distances and solid insulation) |
- |
0 |
|
N/A |
| 29.1, Table No.- 16, Table No.- 17 & Table No.18(Clearances, creepage distances and solid insulation) |
- |
0 |
|
N/A |
| 29.1, Table No.- 16, Table No.- 17 & Table No.18(Clearances, creepage distances and solid insulation) |
- |
0 |
|
N/A |
| 28.2 to 28.4(Screws and connections) |
- |
0 |
|
N/A |
| 28.1, Table No.-14(Screws and connections) |
- |
0 |
|
N/A |
| 27.6(Provision for earthing) |
- |
100 |
|
N/A |
| 27.5(Provision for earthing) |
- |
0 |
|
N/A |
| 27.1 to 27.4(Provision for earthing) |
- |
0 |
|
N/A |
| 26.10 & 26.11(Terminals for external conductors) |
- |
0 |
|
N/A |
| 26.9(Terminals for external conductors) |
- |
0 |
|
N/A |
| 26.1 to 26.8(Terminals for external conductors) |
- |
0 |
|
N/A |
| 25.16 to 25.25(Supply connection and external flexible cords) |
- |
0 |
|
N/A |
| 25.15(Supply connection and external flexible cords) |
- |
0 |
|
N/A |
| 25.14(Supply connection and external flexible cords) |
- |
0 |
|
N/A |
| 25.14(Supply connection and external flexible cords) |
- |
0 |
|
N/A |
| 25.9 to 25.13(Supply connection and external flexible cords) |
- |
0 |
|
N/A |
| 25.8, Table No.-11(Supply connection and external flexible cords) |
- |
0 |
|
N/A |
| 25.5 to 25.7(Supply connection and external flexible cords) |
- |
0 |
|
N/A |
| 25.4(Supply connection and external flexible cords) |
- |
0 |
|
N/A |
| 25.3(Supply connection and external flexible cords) |
- |
100 |
|
N/A |
| 25.2(Supply connection and external flexible cords) |
- |
0 |
|
N/A |
| 25.1(Supply connection and external flexible cords) |
- |
0 |
|
N/A |
| 24.101(Components) |
- |
0 |
|
N/A |
| 24.101(Components) |
- |
0 |
|
N/A |
| 24.2 to 24.6(Components) |
- |
0 |
|
N/A |
| 24.1(Components) |
- |
0 |
|
N/A |
| 23.6 to 23.10(Internal wiring) |
- |
0 |
|
N/A |
| 23.5(Internal wiring) |
- |
100 |
|
N/A |
| 23.4(Internal wiring) |
- |
0 |
|
N/A |
| 23.3(Internal wiring) |
- |
0 |
|
N/A |
| 23.1 & 23.2(Internal wiring) |
- |
0 |
|
N/A |
| 22.111(Constructions) |
- |
0 |
|
N/A |
| 22.111(Constructions) |
- |
0 |
|
N/A |
| 22.11o(Constructions) |
- |
100 |
|
N/A |
| 22.109(Constructions) |
- |
0 |
|
N/A |
| 22.108(Constructions) |
- |
0 |
|
N/A |
| 22.101 to 22.107(Constructions) |
- |
0 |
|
N/A |
| 22.13 to 22.48(Constructions) |
- |
0 |
|
N/A |
| 22.12(Constructions) |
- |
0 |
|
N/A |
| 22.11(Constructions) |
- |
0 |
|
N/A |
| 22.11(Constructions) |
- |
0 |
|
N/A |
| 22.7 to 22.10(Constructions) |
- |
0 |
|
N/A |
| 22.6(Constructions) |
- |
0 |
|
N/A |
| 22.5(Constructions) |
- |
0 |
|
N/A |
| 22.4(Constructions) |
- |
0 |
|
N/A |
| 22.3(Constructions) |
- |
0 |
|
N/A |
| 22.2(Constructions) |
- |
0 |
|
N/A |
| 22.1(Constructions) |
- |
0 |
|
N/A |
| 21.101(MECHANICAL STRENGTH) |
- |
250 |
|
N/A |
| 21.101(MECHANICAL STRENGTH) |
- |
0 |
|
N/A |
| 21.2(MECHANICAL STRENGTH) |
- |
0 |
|
N/A |
| 21.1(MECHANICAL STRENGTH) |
- |
0 |
|
N/A |
| 20.2(Stability and mechanical hazards) |
- |
100 |
|
N/A |
| 20.1(Stability and mechanical hazards) |
- |
0 |
|
N/A |
| 19.104(ABNORMAL OPERATION) |
- |
0 |
|
N/A |
| 19.103(ABNORMAL OPERATION) |
- |
0 |
|
N/A |
| 19.102(ABNORMAL OPERATION) |
- |
0 |
|
N/A |
| 19.101(ABNORMAL OPERATION) |
- |
0 |
|
N/A |
| 19.1 to 19.13, Table No. - 9(ABNORMAL OPERATION) |
- |
0 |
|
N/A |
| 17(Overload protection of transformers and associated circuits) |
- |
0 |
|
N/A |
| 16.3(Insulation resistance test) |
- |
0 |
|
N/A |
| 16.3(Electric strength test) |
- |
0 |
|
N/A |
| 16.1 & 16.2(Leakage current test) |
- |
0 |
|
N/A |
| 15.3(Moisture resistance) |
- |
0 |
|
N/A |
| 15.3(Moisture resistance) |
- |
0 |
|
N/A |
| 15.3(Moisture resistance) |
- |
0 |
|
N/A |
| 15.2(Moisture resistance) |
- |
0 |
|
N/A |
| 15.2(Moisture resistance) |
- |
0 |
|
N/A |
| 15.2(Moisture resistance) |
- |
0 |
|
N/A |
| 15.2(Moisture resistance) |
- |
0 |
|
N/A |
| 15.1(Moisture resistance) |
- |
0 |
|
N/A |
| 14, Table No.- 6 & Table No.-16(Transient over voltages) |
- |
0 |
|
N/A |
| 13.3 and Table No.- 4(Electric strength test) |
- |
0 |
|
N/A |
| 13.1, 13.2(Leakage current test) |
- |
0 |
|
N/A |
| 13.1, 13.2(Leakage current test) |
- |
0 |
|
N/A |
| 11.101(Heating) |
- |
0 |
|
N/A |
| 11.1 to 11.8, Table No.-3(Heating) |
- |
0 |
|
N/A |
| 10.1 & 10.2 -Table No. 1, Table No. 2(Power Input and Current) |
- |
0 |
|
N/A |
| 8.1.5(Protection against access to live parts) |
- |
0 |
|
N/A |
| 8.1.4(Protection against access to live parts) |
- |
0 |
|
N/A |
| 8.1.3(Protection against access to live parts) |
- |
0 |
|
N/A |
| 8.1.2(Protection against access to live parts) |
- |
0 |
|
N/A |
| 8.1, 8.1.1 & 8.2(Protection against access to live parts) |
- |
0 |
|
N/A |
| 7.14(Legibility & Durability of Markings test) |
- |
0 |
|
N/A |
| 7.1 to 7.13, 7.15, 7.16(Marking) |
- |
0 |
|
N/A |
| 32(Radiation ,Toxicity and similar hazards) |
- |
0 |
|
N/A |
| 31(Resistance to Rusting) |
- |
0 |
|
N/A |
| 30(Resistance to Heat & Fire) |
- |
0 |
|
N/A |
| 29(Clearances, Creepage Distances & Solid Insulation) |
- |
0 |
|
N/A |
| 28(Screws & Connections) |
- |
0 |
|
N/A |
| 27(Provision For Earthing) |
- |
0 |
|
N/A |
| 26(Terminals For External Conductors) |
- |
0 |
|
N/A |
| 25(Supply Connection & External Flexible Cords) |
- |
0 |
|
N/A |
| 24(Components) |
- |
0 |
|
N/A |
| 23(Internal wiring) |
- |
0 |
|
N/A |
| 22(Construction) |
- |
0 |
|
N/A |
| 21(Mechanical strength) |
- |
0 |
|
N/A |
| 20(Stability & Mechanical Hazards) |
- |
0 |
|
N/A |
| 19(Abnormal Operation) |
- |
0 |
|
N/A |
| 17(Overload Protection/ Overload Protection of Transformers & Associated Circuits) |
- |
0 |
|
N/A |
| 16(Leakage Current and Electric Strength) |
- |
0 |
|
N/A |
| 15(Moisture Resistance) |
- |
0 |
|
N/A |
| 14(Transient Over Voltage) |
- |
0 |
|
N/A |
| 13(Leakage Current and Electric Strength at Operating Temperature) |
- |
0 |
|
N/A |
| 11(Temperature Rise/ Heating) |
- |
0 |
|
N/A |
| 10(Power Input
& Current) |
- |
0 |
|
N/A |
| 9(Starting Of Motor Operated Appliances) |
- |
0 |
|
N/A |
| 8(Protection against access to live parts) |
- |
0 |
|
N/A |
| 32(Radiation ,Toxicity and similar hazards) |
- |
0 |
|
N/A |
| 31(Resistance to Rusting) |
- |
0 |
|
N/A |
| 30(Resistance to Heat & Fire) |
- |
0 |
|
N/A |
| 29(Clearances, Creepage Distances & Solid Insulation) |
- |
0 |
|
N/A |
| 28(Screws & Connections) |
- |
0 |
|
N/A |
| 27(Provision For Earthing) |
- |
0 |
|
N/A |
| 26(Terminals For External Conductors) |
- |
0 |
|
N/A |
| 25(Supply Connection & External Flexible Cords) |
- |
0 |
|
N/A |
| 24(Components) |
- |
0 |
|
N/A |
| 23(Internal wiring) |
- |
250 |
|
N/A |
| 22(Construction) |
- |
0 |
|
N/A |
| 21(Mechanical strength) |
- |
250 |
|
N/A |
| 20(Stability & Mechanical Hazards) |
- |
0 |
|
N/A |
| 19(Abnormal Operation) |
- |
0 |
|
N/A |
| 17(Overload Protection/ Overload Protection of Transformers & Associated Circuits) |
- |
100 |
|
N/A |
| 16(Leakage Current and Electric Strength) |
- |
0 |
|
N/A |
| 15(Moisture Resistance) |
- |
0 |
|
N/A |
| 14(Transient Over Voltage) |
- |
0 |
|
N/A |
| 13(Leakage Current and Electric Strength at Operating Temperature) |
- |
0 |
|
N/A |
| 11(Temperature Rise/ Heating) |
- |
0 |
|
N/A |
| 10(Power Input
& Current) |
- |
0 |
|
N/A |
| 9(Starting Of Motor Operated Appliances) |
- |
0 |
|
N/A |
| 8(Protection against access to live parts) |
- |
0 |
|
N/A |
| 19.11.4.1(Electrostatic discharges) |
- |
250 |
|
N/A |
| 19.11.4.2(Radiated fields) |
- |
0 |
|
N/A |
| 19.11.4.3(Fast transient bursts) |
- |
0 |
|
N/A |
| 19.11.4.4(Surge immunity test) |
- |
250 |
|
N/A |
| 19.11.4.5(Immunity to conducted discharges) |
- |
0 |
|
N/A |
| 19.11.4.6(Class 3 Voltage dips and interruptions) |
- |
0 |
|
N/A |
| 19.11.4.7(Harmonics) |
- |
0 |
|
N/A |
|
02 Sep, 2028 |
- Included w.e.f 13.11.2025
"Cl. 32 IS 302-2-9 (Radiation, Toxicity and similar hazards)
19.11.4.2 (Radiated fields)
19.11.4.3 (Fast transient bursts)
19.11.4.5 (Immunity to conducted discharges)
19.11.4.6 (Class 3 Voltage dips and interruptions)
19.11.4.7 (Harmonics)" |
| 14 |
IS 302 : Part 2 : Sec 46 (1993) |
Safety of household and similar electrical appliances: Part 2 particular requirements: Sec 46 electric steam cookers |
-- |
24000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4(General) |
- |
250 |
|
N/A |
| 5(Rating) |
- |
500 |
|
N/A |
| 6(Classification) |
- |
250 |
|
N/A |
| 7(Marking) |
- |
1000 |
|
N/A |
| 8("8 PROTECTION AGAINST ELECTRIC
SHOCK ") |
- |
1000 |
|
N/A |
| 9("STARTING OF MOTOR-OPERATING
APPLIANCES ") |
- |
0 |
|
N/A |
| 10(INPUT AND CURRENT) |
- |
1000 |
|
N/A |
| 11(TEMPERATURE RISE) |
- |
1000 |
|
N/A |
| 12("OPERATION UNDER OVERLOAD
CONDITIONS OF APPLIANCES WITH
HEATING ELEMENTS") |
- |
0 |
|
N/A |
| 13(" ELECTRICAL INSULATION AND LEKAGE
CURRENT AT OPERATING TEMPERATURE ") |
- |
1000 |
|
N/A |
| 14("RADIO AND TELEVISION
INTERFERENCE SUPPRESSION") |
- |
1000 |
|
N/A |
| 15(MOISTURE RESISTANCE) |
- |
1000 |
|
N/A |
| 16("INSULATION RESlSTANCE AND
specified in 16.2.
ELECTRIC SHOCK STRENGTH ( AFTER
HUMIDITY TREATMENT )") |
- |
1000 |
|
N/A |
| 17(OVERLOAD PROTECTION) |
- |
1000 |
|
N/A |
| 19(ABNORMAL OPERATION) |
- |
1000 |
|
N/A |
| 19.11.4.1(Electrostatic discharges) |
- |
1000 |
|
N/A |
| 19.11.4.2(Radiated fields) |
- |
0 |
|
N/A |
| 19.11.4.3(Fast transient bursts) |
- |
0 |
|
N/A |
| 19.11.4.4(Surge immunity test) |
- |
1000 |
|
N/A |
| 19.11.4.5(Immunity to conducted discharges) |
- |
0 |
|
N/A |
| 19.11.4.6(Class 3 Voltage dips and interruptions) |
- |
0 |
|
N/A |
| 19.11.4.7(Harmonics) |
- |
0 |
|
N/A |
| 20("STABILITY AND MECHANICAL
HAZARDS") |
- |
1000 |
|
N/A |
| 21(MECHANICAL STRENGTH) |
- |
500 |
|
N/A |
| 21(MECHANICAL STRENGTH) |
- |
500 |
|
N/A |
| 22(CONSTRUCTION) |
- |
500 |
|
N/A |
| 22(CONSTRUCTION) |
- |
500 |
|
N/A |
| 23(INTERNAL WIRING) |
- |
1000 |
|
N/A |
| 24(COMPONENTS) |
- |
1000 |
|
N/A |
| 25("SUPPLY CONNECTION AND EXTERNAL
FLEXIBLE CABLES AND CORDS ") |
- |
1000 |
|
N/A |
| 26("TERMINALS FOR EXTERNAL
CONDUCTORS") |
- |
1000 |
|
N/A |
| 27(PROVISION FOR EARTHING) |
- |
1000 |
|
N/A |
| 28(SCREWS AND CONNECTIONS) |
- |
1000 |
|
N/A |
| 30("RESISTANCE TO HEAT, FIRE AND
TRACKING ") |
- |
1000 |
|
N/A |
| 31(RESISTANCE TO RUSTING) |
- |
500 |
|
N/A |
| 31(RESISTANCE TO RUSTING) |
- |
500 |
|
- |
| 32(RADIATION HAZARDS) |
- |
0 |
|
N/A |
| 19.11.4.1(Electrostatic discharges) |
- |
0 |
|
N/A |
| 19.11.4.2(Radiated fields) |
- |
0 |
|
N/A |
| 19.11.4.3(Fast transient bursts) |
- |
0 |
|
N/A |
| 19.11.4.2(Radiated fields) |
- |
0 |
|
N/A |
| 19.11.4.4(Surge immunity test) |
- |
0 |
|
N/A |
| 19.11.4.5(Immunity to conducted discharges) |
- |
0 |
|
N/A |
| 19.11.4.6(Class 3 Voltage dips and interruptions) |
- |
0 |
|
N/A |
| 19.11.4.7(Harmonics) |
- |
0 |
|
N/A |
| 20("STABILITY AND MECHANICAL
HAZARDS") |
- |
0 |
|
N/A |
| 21(MECHANICAL STRENGTH) |
- |
0 |
|
N/A |
| 22(CONSTRUCTION) |
- |
0 |
|
N/A |
| 23(INTERNAL WIRING) |
- |
0 |
|
N/A |
| 24(COMPONENTS) |
- |
0 |
|
N/A |
| 25("SUPPLY CONNECTION AND EXTERNAL
FLEXIBLE CABLES AND CORDS ") |
- |
0 |
|
N/A |
| 26("TERMINALS FOR EXTERNAL
CONDUCTORS") |
- |
0 |
|
N/A |
| 27(PROVISION FOR EARTHING) |
- |
0 |
|
N/A |
| 28(SCREWS AND CONNECTIONS) |
- |
0 |
|
N/A |
| 30("RESISTANCE TO HEAT, FIRE AND
TRACKING ") |
- |
0 |
|
N/A |
| 31(RESISTANCE TO RUSTING) |
- |
0 |
|
N/A |
| 32(RADIATION HAZARDS) |
- |
0 |
|
N/A |
| 4(General) |
- |
0 |
|
N/A |
| 5(Rating) |
- |
0 |
|
N/A |
| 6(Classification) |
- |
0 |
|
N/A |
| 7(Marking) |
- |
0 |
|
N/A |
| 8("8 PROTECTION AGAINST ELECTRIC
SHOCK ") |
- |
0 |
|
N/A |
| 9("STARTING OF MOTOR-OPERATING
APPLIANCES ") |
- |
0 |
|
N/A |
| 10(INPUT AND CURRENT) |
- |
0 |
|
N/A |
| 11(TEMPERATURE RISE) |
- |
0 |
|
N/A |
| 12("OPERATION UNDER OVERLOAD
CONDITIONS OF APPLIANCES WITH
HEATING ELEMENTS") |
- |
0 |
|
N/A |
| 13(" ELECTRICAL INSULATION AND LEKAGE
CURRENT AT OPERATING TEMPERATURE ") |
- |
0 |
|
N/A |
| 14("RADIO AND TELEVISION
INTERFERENCE SUPPRESSION") |
- |
0 |
|
N/A |
| 15(MOISTURE RESISTANCE) |
- |
0 |
|
N/A |
| 16("INSULATION RESlSTANCE AND
specified in 16.2.
ELECTRIC SHOCK STRENGTH ( AFTER
HUMIDITY TREATMENT )") |
- |
0 |
|
N/A |
| 17(OVERLOAD PROTECTION) |
- |
0 |
|
N/A |
| 19(ABNORMAL OPERATION) |
- |
0 |
|
N/A |
| 19.11.4.1(Electrostatic discharges) |
- |
0 |
|
N/A |
| 19.11.4.2(Radiated fields) |
- |
0 |
|
N/A |
| 19.11.4.3(Fast transient bursts) |
- |
0 |
|
N/A |
| 19.11.4.4(Surge immunity test) |
- |
0 |
|
N/A |
| 19.11.4.5(Immunity to conducted discharges) |
- |
0 |
|
N/A |
| 19.11.4.6(Class 3 Voltage dips and interruptions) |
- |
0 |
|
N/A |
| 19.11.4.7(Harmonics) |
- |
0 |
|
N/A |
| 20("STABILITY AND MECHANICAL
HAZARDS") |
- |
0 |
|
N/A |
| 21(MECHANICAL STRENGTH) |
- |
0 |
|
N/A |
| 21(MECHANICAL STRENGTH) |
- |
0 |
|
N/A |
| 22(CONSTRUCTION) |
- |
0 |
|
N/A |
| 22(CONSTRUCTION) |
- |
0 |
|
N/A |
| 23(INTERNAL WIRING) |
- |
0 |
|
N/A |
| 24(COMPONENTS) |
- |
0 |
|
N/A |
| 25("SUPPLY CONNECTION AND EXTERNAL
FLEXIBLE CABLES AND CORDS ") |
- |
0 |
|
N/A |
| 26("TERMINALS FOR EXTERNAL
CONDUCTORS") |
- |
0 |
|
N/A |
| 27(PROVISION FOR EARTHING) |
- |
0 |
|
N/A |
| 28(SCREWS AND CONNECTIONS) |
- |
0 |
|
N/A |
| 30("RESISTANCE TO HEAT, FIRE AND
TRACKING ") |
- |
0 |
|
N/A |
| 31(RESISTANCE TO RUSTING) |
- |
0 |
|
N/A |
| 31(RESISTANCE TO RUSTING) |
- |
0 |
|
N/A |
| 32(RADIATION HAZARDS) |
- |
0 |
|
N/A |
| 19.11.4.1(Electrostatic discharges) |
- |
0 |
|
N/A |
| 19.11.4.2(Radiated fields) |
- |
0 |
|
N/A |
| 19.11.4.3(Fast transient bursts) |
- |
0 |
|
N/A |
| 19.11.4.2(Radiated fields) |
- |
0 |
|
N/A |
| 19.11.4.4(Surge immunity test) |
- |
0 |
|
N/A |
| 19.11.4.5(Immunity to conducted discharges) |
- |
0 |
|
N/A |
| 19.11.4.6(Class 3 Voltage dips and interruptions) |
- |
0 |
|
N/A |
| 19.11.4.7(Harmonics) |
- |
0 |
|
N/A |
| 20("STABILITY AND MECHANICAL
HAZARDS") |
- |
0 |
|
N/A |
| 21(MECHANICAL STRENGTH) |
- |
0 |
|
N/A |
| 22(CONSTRUCTION) |
- |
0 |
|
N/A |
| 23(INTERNAL WIRING) |
- |
0 |
|
N/A |
| 24(COMPONENTS) |
- |
0 |
|
N/A |
| 25("SUPPLY CONNECTION AND EXTERNAL
FLEXIBLE CABLES AND CORDS ") |
- |
0 |
|
N/A |
| 26("TERMINALS FOR EXTERNAL
CONDUCTORS") |
- |
0 |
|
N/A |
| 27(PROVISION FOR EARTHING) |
- |
0 |
|
N/A |
| 28(SCREWS AND CONNECTIONS) |
- |
0 |
|
N/A |
| 30("RESISTANCE TO HEAT, FIRE AND
TRACKING ") |
- |
0 |
|
N/A |
| 31(RESISTANCE TO RUSTING) |
- |
0 |
|
N/A |
| 32(RADIATION HAZARDS) |
- |
0 |
|
N/A |
| 4(General) |
- |
- |
|
- |
| 5(Rating) |
- |
- |
|
- |
| 6(Classification) |
- |
- |
|
- |
| 7(Marking) |
- |
- |
|
- |
| 8("8 PROTECTION AGAINST ELECTRIC
SHOCK ") |
- |
- |
|
- |
| 9("STARTING OF MOTOR-OPERATING
APPLIANCES ") |
- |
- |
|
- |
| 10(INPUT AND CURRENT) |
- |
- |
|
- |
| 11(TEMPERATURE RISE) |
- |
- |
|
- |
| 12("OPERATION UNDER OVERLOAD
CONDITIONS OF APPLIANCES WITH
HEATING ELEMENTS") |
- |
- |
|
- |
| 13(" ELECTRICAL INSULATION AND LEKAGE
CURRENT AT OPERATING TEMPERATURE ") |
- |
- |
|
- |
| 14("RADIO AND TELEVISION
INTERFERENCE SUPPRESSION") |
- |
- |
|
- |
| 15(MOISTURE RESISTANCE) |
- |
- |
|
- |
| 16("INSULATION RESlSTANCE AND
specified in 16.2.
ELECTRIC SHOCK STRENGTH ( AFTER
HUMIDITY TREATMENT )") |
- |
- |
|
- |
| 17(OVERLOAD PROTECTION) |
- |
- |
|
- |
| 19(ABNORMAL OPERATION) |
- |
- |
|
- |
| 19.11.4.1(Electrostatic discharges) |
- |
- |
|
- |
| 19.11.4.2(Radiated fields) |
- |
- |
|
- |
| 19.11.4.3(Fast transient bursts) |
- |
- |
|
- |
| 19.11.4.4(Surge immunity test) |
- |
- |
|
- |
| 19.11.4.5(Immunity to conducted discharges) |
- |
- |
|
- |
| 19.11.4.6(Class 3 Voltage dips and interruptions) |
- |
- |
|
- |
| 19.11.4.7(Harmonics) |
- |
- |
|
- |
| 20("STABILITY AND MECHANICAL
HAZARDS") |
- |
- |
|
- |
| 21(MECHANICAL STRENGTH) |
- |
- |
|
- |
| 21(MECHANICAL STRENGTH) |
- |
- |
|
- |
| 22(CONSTRUCTION) |
- |
- |
|
- |
| 22(CONSTRUCTION) |
- |
- |
|
- |
| 23(INTERNAL WIRING) |
- |
- |
|
- |
| 24(COMPONENTS) |
- |
- |
|
- |
| 25("SUPPLY CONNECTION AND EXTERNAL
FLEXIBLE CABLES AND CORDS ") |
- |
- |
|
- |
| 26("TERMINALS FOR EXTERNAL
CONDUCTORS") |
- |
- |
|
- |
| 27(PROVISION FOR EARTHING) |
- |
- |
|
- |
| 28(SCREWS AND CONNECTIONS) |
- |
- |
|
- |
| 30("RESISTANCE TO HEAT, FIRE AND
TRACKING ") |
- |
- |
|
- |
| 31(RESISTANCE TO RUSTING) |
- |
- |
|
- |
| 31(RESISTANCE TO RUSTING) |
- |
- |
|
- |
| 32(RADIATION HAZARDS) |
- |
- |
|
- |
| 19.11.4.1(Electrostatic discharges) |
- |
- |
|
- |
| 19.11.4.2(Radiated fields) |
- |
- |
|
- |
| 19.11.4.3(Fast transient bursts) |
- |
- |
|
- |
| 19.11.4.2(Radiated fields) |
- |
- |
|
- |
| 19.11.4.4(Surge immunity test) |
- |
- |
|
- |
| 19.11.4.5(Immunity to conducted discharges) |
- |
- |
|
- |
| 19.11.4.6(Class 3 Voltage dips and interruptions) |
- |
- |
|
- |
| 19.11.4.7(Harmonics) |
- |
- |
|
- |
| 20("STABILITY AND MECHANICAL
HAZARDS") |
- |
- |
|
- |
| 21(MECHANICAL STRENGTH) |
- |
- |
|
- |
| 22(CONSTRUCTION) |
- |
- |
|
- |
| 23(INTERNAL WIRING) |
- |
- |
|
- |
| 24(COMPONENTS) |
- |
- |
|
- |
| 25("SUPPLY CONNECTION AND EXTERNAL
FLEXIBLE CABLES AND CORDS ") |
- |
- |
|
- |
| 26("TERMINALS FOR EXTERNAL
CONDUCTORS") |
- |
- |
|
- |
| 27(PROVISION FOR EARTHING) |
- |
- |
|
- |
| 28(SCREWS AND CONNECTIONS) |
- |
- |
|
- |
| 30("RESISTANCE TO HEAT, FIRE AND
TRACKING ") |
- |
- |
|
- |
| 31(RESISTANCE TO RUSTING) |
- |
- |
|
- |
| 32(RADIATION HAZARDS) |
- |
- |
|
- |
|
02 Sep, 2028 |
- Included w.e.f 19.12.2025
"32 (RADIATION HAZARDS)
Cl-19.11.4.2 (Radiated Fields)
Cl-19.11.4.3 (Fast transient bursts)
Cl-19.11.4.5 (Immunity to conducted discharge)
Cl-19.11.4.6 (Voltage dips and interruptions)
Cl-19.11.4.7 (Harmonics)
24 (COMPONENTS)" |
| 15 |
IS 302 : Part 2 : Sec 208 (1994) |
Safety of household and similar electrtcal appliances: Part 2 particular requirements: Sec 208 single walled baking ovens |
-- |
30000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 3(GENERAL REQUIREMENT) |
- |
0 |
|
N/A |
| 4(GENERAL NOTES ON TESTS) |
- |
0 |
|
N/A |
| 5(RATING) |
- |
250 |
|
N/A |
| 6(CLASSIFICATION) |
- |
250 |
|
N/A |
| 7(MARKING) |
- |
500 |
|
N/A |
| 8(PROTECTION AGAINST ELECTRIC SHOCK) |
- |
1000 |
|
N/A |
| 10(INPUT AND CURRENT) |
- |
2000 |
|
N/A |
| 11(TEMPERATURE RISE) |
- |
2000 |
|
N/A |
| 12(OPERATLON UNDER OVERLOAD CONDITIONS OF APPLIANCES
WITH HEATING ELEMENTS) |
- |
0 |
|
N/A |
| 13(ELECTRICAL INSULATION AND LEAKAGE CURRENT
AT OPERATING TEMPERATURE) |
- |
1000 |
|
N/A |
| 14(RADIO AND TELEVISION INTERFERENCE SUPPRESSION) |
- |
2000 |
|
N/A |
| 15(MOISTURE RESESTANCE) |
- |
2000 |
|
N/A |
| 16(INSULATION RESISTANCE AND ELECTRIC SHOCK STRENGTH
( AFTER HUMIDITY TREATMENT )) |
- |
1000 |
|
N/A |
| 17(OVERLOAD PROTECTION) |
- |
1000 |
|
N/A |
| 19(ABNORMAL OPERATION) |
- |
2000 |
|
N/A |
| 20(STABILITY AND MECHANICAL HAZARDS) |
- |
1000 |
|
N/A |
| 21(MECHANICAL STRENGTH) |
- |
1000 |
|
N/A |
| 22(CONSTRUCTION) |
- |
2000 |
|
N/A |
| 23(INTERNAL WIRING) |
- |
1000 |
|
N/A |
| 24(COMPONENTS) |
- |
1000 |
|
N/A |
| 25(SUPPLY CONNECTION AND EXTERNAL FLEXIBLE CABLES AND CORDS) |
- |
1000 |
|
N/A |
| 26(TERMINALS FOR EXTERNAL CONDUCTORS) |
- |
1000 |
|
N/A |
| 27(PROVISION FOR EARTHING) |
- |
1000 |
|
N/A |
| 28(SCREWS AND CONNECTIONS) |
- |
1000 |
|
N/A |
| 29(CREEPAGE DISTANCES, CLEARANCES AND DISTANCES THROUGH INSULATION) |
- |
1000 |
|
N/A |
| 30(RESISTANCE TO HEAT, FIRE AND TACKING) |
- |
1000 |
|
N/A |
| 31(RESISTANCE TO RUSTING) |
- |
1000 |
|
N/A |
| 32(RADIATION HAZARDS) |
- |
0 |
|
N/A |
| 101.1(Type Tests) |
- |
0 |
|
N/A |
| 101.2(Acceptance Tests) |
- |
0 |
|
N/A |
| 101.3(Routine Tests) |
- |
0 |
|
N/A |
| Cl-19.11.4.1(Electrostatic discharge) |
- |
1000 |
|
N/A |
| Cl-19.11.4.2(Radiated Fields) |
- |
0 |
|
N/A |
| Cl-19.11.4.3(Fast transient bursts) |
- |
0 |
|
N/A |
| Cl-19.11.4.4(Surge Immunity test) |
- |
1000 |
|
N/A |
| Cl-19.11.4.5(Immunity to conducted discharge) |
- |
0 |
|
N/A |
| Cl-19.11.4.6(Voltage dips and interruptions) |
- |
0 |
|
N/A |
| Cl-19.11.4.7(Harmonics) |
- |
0 |
|
N/A |
| 3(GENERAL REQUIREMENT) |
- |
- |
|
- |
| 4(GENERAL NOTES ON TESTS) |
- |
- |
|
- |
| 5(RATING) |
- |
- |
|
- |
| 6(CLASSIFICATION) |
- |
- |
|
- |
| 7(MARKING) |
- |
- |
|
- |
| 8(PROTECTION AGAINST ELECTRIC SHOCK) |
- |
- |
|
- |
| 10(INPUT AND CURRENT) |
- |
- |
|
- |
| 11(TEMPERATURE RISE) |
- |
- |
|
- |
| 12(OPERATLON UNDER OVERLOAD CONDITIONS OF APPLIANCES
WITH HEATING ELEMENTS) |
- |
- |
|
- |
| 13(ELECTRICAL INSULATION AND LEAKAGE CURRENT
AT OPERATING TEMPERATURE) |
- |
- |
|
- |
| 14(RADIO AND TELEVISION INTERFERENCE SUPPRESSION) |
- |
- |
|
- |
| 15(MOISTURE RESESTANCE) |
- |
- |
|
- |
| 16(INSULATION RESISTANCE AND ELECTRIC SHOCK STRENGTH
( AFTER HUMIDITY TREATMENT )) |
- |
- |
|
- |
| 17(OVERLOAD PROTECTION) |
- |
- |
|
- |
| 19(ABNORMAL OPERATION) |
- |
- |
|
- |
| 20(STABILITY AND MECHANICAL HAZARDS) |
- |
- |
|
- |
| 21(MECHANICAL STRENGTH) |
- |
- |
|
- |
| 22(CONSTRUCTION) |
- |
- |
|
- |
| 23(INTERNAL WIRING) |
- |
- |
|
- |
| 24(COMPONENTS) |
- |
- |
|
- |
| 25(SUPPLY CONNECTION AND EXTERNAL FLEXIBLE CABLES AND CORDS) |
- |
- |
|
- |
| 26(TERMINALS FOR EXTERNAL CONDUCTORS) |
- |
- |
|
- |
| 27(PROVISION FOR EARTHING) |
- |
- |
|
- |
| 28(SCREWS AND CONNECTIONS) |
- |
- |
|
- |
| 29(CREEPAGE DISTANCES, CLEARANCES AND DISTANCES THROUGH INSULATION) |
- |
- |
|
- |
| 30(RESISTANCE TO HEAT, FIRE AND TACKING) |
- |
- |
|
- |
| 31(RESISTANCE TO RUSTING) |
- |
- |
|
- |
| 32(RADIATION HAZARDS) |
- |
- |
|
- |
| 101.1(Type Tests) |
- |
- |
|
- |
| 101.2(Acceptance Tests) |
- |
- |
|
- |
| 101.3(Routine Tests) |
- |
- |
|
- |
| Cl-19.11.4.1(Electrostatic discharge) |
- |
- |
|
- |
| Cl-19.11.4.2(Radiated Fields) |
- |
- |
|
- |
| Cl-19.11.4.3(Fast transient bursts) |
- |
- |
|
- |
| Cl-19.11.4.4(Surge Immunity test) |
- |
- |
|
- |
| Cl-19.11.4.5(Immunity to conducted discharge) |
- |
- |
|
- |
| Cl-19.11.4.6(Voltage dips and interruptions) |
- |
- |
|
- |
| Cl-19.11.4.7(Harmonics) |
- |
- |
|
- |
|
02 Sep, 2028 |
- Included w.e.f 19.12.2025
"32 (RADIATION HAZARDS)
Cl-19.11.4.2 (Radiated Fields)
Cl-19.11.4.3 (Fast transient bursts)
Cl-19.11.4.5 (Immunity to conducted discharge)
Cl-19.11.4.6 (Voltage dips and interruptions)
Cl-19.11.4.7 (Harmonics)
24 (COMPONENTS)" |
| 16 |
IS 302 : Part 2 : Sec 204 (1994) |
Safety of household and similar electrical appliances: Part 2 particular requirements: Sec 204 electric water boilers |
-- |
40000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 3(GENERAL REQUIREMENT) |
- |
0 |
|
N/A |
| 4(GENERAL NOTES ON TESTS) |
- |
0 |
|
N/A |
| 5(RATING) |
- |
500 |
|
N/A |
| 6(CLASSIFICATION) |
- |
500 |
|
N/A |
| 7(MARKING) |
- |
1000 |
|
N/A |
| 8(PROTECTION AGAINST ELECTRIC SHOCK) |
- |
1000 |
|
N/A |
| 9(STARTING OF MOTOR-OPERATED APPLIANCES) |
- |
0 |
|
N/A |
| 10(INPUT AND CURRENT) |
- |
2000 |
|
N/A |
| 11(TEMPRATURE RISE) |
- |
2000 |
|
N/A |
| 12(OPERATION TJNDER OVERLOAD CONDITIONS
OF APPLIANCES WITH HEATING ELEMENTS) |
- |
0 |
|
N/A |
| 13(ELECTRICAL INSULATION AND LEAKAGE CURRENT AT
OPERATING TEMPERATURE) |
- |
2000 |
|
N/A |
| 14(RADIO AND TELEVISION INTERFERENCE SUPPRESSION) |
- |
2000 |
|
N/A |
| 15(MOISTURE RESISTANCE) |
- |
3000 |
|
N/A |
| 16(INSULATION RESISTANCE AND ELECTRIC STRENGTH) |
- |
2000 |
|
N/A |
| 17(OVERLOAD PROTECTION) |
- |
2000 |
|
N/A |
| 18(ENDURANCE ) |
- |
0 |
|
N/A |
| 19(ABNORMAL OPERATION) |
- |
3000 |
|
N/A |
| 20(STABILITY AND MECHANICAL HAZARDS) |
- |
2000 |
|
N/A |
| 21(MECHANICAL STRENGTH) |
- |
2000 |
|
N/A |
| 22(CONSTRUCTION) |
- |
3000 |
|
N/A |
| 23(INTERNAL WIRING) |
- |
1000 |
|
N/A |
| 24(COMPONENTS) |
- |
1000 |
|
N/A |
| 25(SUPPLY CONNECTION AND EXTERNAL FLEXIBLE CABLES AND CORDS) |
- |
2000 |
|
N/A |
| 26(TERMINALS FOR EXTERNAL CONDUCTORS) |
- |
1000 |
|
N/A |
| 27(PROVISION FOR EARTHING) |
- |
1000 |
|
N/A |
| 28(SCREWS AND CONNECTIONS) |
- |
1000 |
|
N/A |
| 29(CREEPAGE DISTANCES, CLEARANCES AND DISTANCES THROUGH INSULATION) |
- |
1000 |
|
N/A |
| 30(RESISTANCE TO HEAT, FIRE AND TACKING) |
- |
1000 |
|
N/A |
| 31(RESISTANCE TO RUSTING) |
- |
1000 |
|
N/A |
| 32(RADIATION HAZARDS) |
- |
0 |
|
N/A |
| 101.1(Type Tests) |
- |
0 |
|
N/A |
| 101.2(Acceptance Tests) |
- |
0 |
|
N/A |
| 101.3(Routine Tests) |
- |
0 |
|
N/A |
| Cl-19.11.4.1(Electrostatic discharge) |
- |
1000 |
|
N/A |
| Cl-19.11.4.2(Radiated Fields) |
- |
0 |
|
N/A |
| Cl-19.11.4.3(Fast transient bursts) |
- |
0 |
|
N/A |
| Cl-19.11.4.4(Surge Immunity test) |
- |
1000 |
|
N/A |
| Cl-19.11.4.5(Immunity to conducted discharge) |
- |
0 |
|
N/A |
| Cl-19.11.4.6(Voltage dips and interruptions) |
- |
0 |
|
N/A |
| Cl-19.11.4.7(Harmonics) |
- |
0 |
|
N/A |
| 3(GENERAL REQUIREMENT) |
- |
0 |
|
- |
| 4(GENERAL NOTES ON TESTS) |
- |
0 |
|
- |
| 5(RATING) |
- |
0 |
|
- |
| 6(CLASSIFICATION) |
- |
0 |
|
- |
| 7(MARKING) |
- |
0 |
|
- |
| 8(PROTECTION AGAINST ELECTRIC SHOCK) |
- |
0 |
|
- |
| 9(STARTING OF MOTOR-OPERATED APPLIANCES) |
- |
0 |
|
- |
| 10(INPUT AND CURRENT) |
- |
0 |
|
- |
| 11(TEMPRATURE RISE) |
- |
0 |
|
- |
| 12(OPERATION TJNDER OVERLOAD CONDITIONS
OF APPLIANCES WITH HEATING ELEMENTS) |
- |
0 |
|
- |
| 13(ELECTRICAL INSULATION AND LEAKAGE CURRENT AT
OPERATING TEMPERATURE) |
- |
0 |
|
- |
| 14(RADIO AND TELEVISION INTERFERENCE SUPPRESSION) |
- |
0 |
|
- |
| 15(MOISTURE RESISTANCE) |
- |
0 |
|
- |
| 16(INSULATION RESISTANCE AND ELECTRIC STRENGTH) |
- |
0 |
|
- |
| 17(OVERLOAD PROTECTION) |
- |
0 |
|
- |
| 18(ENDURANCE ) |
- |
0 |
|
- |
| 19(ABNORMAL OPERATION) |
- |
0 |
|
- |
| 20(STABILITY AND MECHANICAL HAZARDS) |
- |
0 |
|
- |
| 21(MECHANICAL STRENGTH) |
- |
0 |
|
- |
| 22(CONSTRUCTION) |
- |
0 |
|
- |
| 23(INTERNAL WIRING) |
- |
0 |
|
- |
| 24(COMPONENTS) |
- |
0 |
|
- |
| 25(SUPPLY CONNECTION AND EXTERNAL FLEXIBLE CABLES AND CORDS) |
- |
0 |
|
- |
| 26(TERMINALS FOR EXTERNAL CONDUCTORS) |
- |
0 |
|
- |
| 27(PROVISION FOR EARTHING) |
- |
0 |
|
- |
| 28(SCREWS AND CONNECTIONS) |
- |
0 |
|
- |
| 29(CREEPAGE DISTANCES, CLEARANCES AND DISTANCES THROUGH INSULATION) |
- |
0 |
|
- |
| 30(RESISTANCE TO HEAT, FIRE AND TACKING) |
- |
0 |
|
- |
| 31(RESISTANCE TO RUSTING) |
- |
0 |
|
- |
| 32(RADIATION HAZARDS) |
- |
0 |
|
- |
| 101.1(Type Tests) |
- |
0 |
|
- |
| 101.2(Acceptance Tests) |
- |
0 |
|
- |
| 101.3(Routine Tests) |
- |
0 |
|
- |
| Cl-19.11.4.1(Electrostatic discharge) |
- |
0 |
|
- |
| Cl-19.11.4.2(Radiated Fields) |
- |
0 |
|
- |
| Cl-19.11.4.3(Fast transient bursts) |
- |
0 |
|
- |
| Cl-19.11.4.4(Surge Immunity test) |
- |
0 |
|
- |
| Cl-19.11.4.5(Immunity to conducted discharge) |
- |
0 |
|
- |
| Cl-19.11.4.6(Voltage dips and interruptions) |
- |
0 |
|
- |
| Cl-19.11.4.7(Harmonics) |
- |
0 |
|
- |
|
02 Sep, 2028 |
- Included w.e.f 13.11.2025
" 32 (RADIATION HAZARDS)
Cl-19.11.4.2 (Radiated Fields)
Cl-19.11.4.3 (Fast transient bursts)
Cl-19.11.4.5 (Immunity to conducted discharge)
Cl-19.11.4.6 (Voltage dips and interruptions)
Cl-19.11.4.7 (Harmonics)" |
| 17 |
IS 302 : Part 2 : Sec 25 (2014) |
Safety of household and similar electrical appliances: Part 2 Particular requirements: Section 25 Microwave ovens |
-- |
35000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6.0(Classification) |
- |
1000 |
|
N/A |
| 7(Marking and instructions) |
- |
1000 |
|
N/A |
| 8(Protection against live parts) |
- |
1000 |
|
N/A |
| 9(STARTING OF MOTOR-OPERATED APPLIANCES) |
- |
0 |
|
N/A |
| 10(POWER INPUT AND CURRENT) |
- |
1000 |
|
N/A |
| 11(HEATING) |
- |
2000 |
|
N/A |
| 13(LEAKAGE CURRENT AND ELECTRIC STRENGTH AT OPERATING TEMPERATURE) |
- |
1000 |
|
N/A |
| 14(IMPULSE VOLTAGE TEST) |
- |
2000 |
|
N/A |
| 15(HUMIDITY TREATMENT TEST) |
- |
2000 |
|
N/A |
| 16(LEAKAGE CURRENT AND ELECTRIC STRENGTH) |
- |
1000 |
|
N/A |
| 17(OVERLOAD PROTECTION OF TRANSFORMERS AND ASSOCIATED CIRCUITS) |
- |
1000 |
|
N/A |
| 18(ENDURANCE) |
- |
1000 |
|
N/A |
| 19(ABNORMAL OPERATION) |
- |
1000 |
|
N/A |
| 20(STABILITY AND MECHANICAL HAZARDS) |
- |
1000 |
|
N/A |
| 21(MECHANICAL STRENGTH) |
- |
1000 |
|
N/A |
| 22(CONSTRUCTION) |
- |
2000 |
|
N/A |
| 23(INTERNAL WIRING) |
- |
1000 |
|
N/A |
| 24(COMPONENTS) |
- |
1000 |
|
N/A |
| 25(SUPPLY CONNECTION AND EXTERNAL FLEXIBLE CORDS) |
- |
1000 |
|
N/A |
| 26(TERMINALS FOR EXTERNAL CONDUCTORS) |
- |
1000 |
|
N/A |
| 27(PROVISION FOR EARTHING) |
- |
1000 |
|
N/A |
| 28(SCREWS AND CONNECTIONS) |
- |
1000 |
|
N/A |
| 29(CLEARANCES, CREEPAGE DISTANCES AND SOLID INSULATION) |
- |
1000 |
|
N/A |
| 30(RESISTANCE TO HEAT AND FIRE) |
- |
2000 |
|
N/A |
| 31(RESISTANCE TO RUSTING) |
- |
1000 |
|
N/A |
| 32(RADIATION, TOXICITY AND SIMILAR HAZARDS) |
- |
2000 |
|
N/A |
| 22.32(Oxygen bomb for rubber material) |
- |
0 |
|
N/A |
| 22.46(Software) |
- |
0 |
|
N/A |
| Cl-19.11.4.1(Electrostatic discharge) |
- |
2000 |
|
N/A |
| Cl-19.11.4.2(Radiated Fields) |
- |
0 |
|
N/A |
| Cl-19.11.4.3(Fast transient bursts) |
- |
0 |
|
N/A |
| Cl-19.11.4.4(Surge Immunity test) |
- |
2000 |
|
N/A |
| Cl-19.11.4.5(Immunity to conducted discharge) |
- |
0 |
|
N/A |
| Cl-19.11.4.6(Voltage dips and interruptions) |
- |
0 |
|
N/A |
| Cl-19.11.4.7(Harmonics) |
- |
0 |
|
N/A |
|
02 Sep, 2028 |
- Included w.e.f 13.11.2025
" 22.32 (Oxygen bomb for rubber material)
22.46 (Software)
Cl-19.11.4.2 (Radiated Fields)
Cl-19.11.4.3 (Fast transient bursts)
Cl-19.11.4.5 (Immunity to conducted discharge)
Cl-19.11.4.6 (Voltage dips and interruptions)
Cl-19.11.4.7 (Harmonics)" |
| 18 |
IS 302 : Part 2 : Sec 13 (2024) |
Household and Similar Electrical Appliances âSafety Part 2 Particular Requirements Section 13 Deep Fat Fryers, Frying Pans and Similar Appliances (First Revision) |
-- |
20000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 7(Marking and instructions) |
- |
500 |
|
N/A |
| 8(Protection against access to live parts) |
- |
500 |
|
N/A |
| 10(Power input and current) |
- |
1000 |
|
N/A |
| 11(Heating) |
- |
1000 |
|
N/A |
| 13.1 &13.2(Leakage current test) |
- |
500 |
|
N/A |
| 13.1 &13.3(Electric strength test) |
- |
500 |
|
N/A |
| 14(Transient overvoltages) |
- |
1000 |
|
N/A |
| 15(Moisture resistance) |
- |
500 |
|
N/A |
| 15.3(Moisture resistance) |
- |
500 |
|
N/A |
| 15.101(Moisture resistance) |
- |
500 |
|
N/A |
| 16.1 &16.2(Leakage current test) |
- |
500 |
|
N/A |
| 16.1 & 16.3(Electric strength test) |
- |
500 |
|
N/A |
| 17(Overload protection of transformers and associated circuits) |
- |
1000 |
|
N/A |
| 19.1 to 19.13, Table No. - 9(Abnormal operation) |
- |
500 |
|
N/A |
| 19.101 to to 19.102(Abnormal operation) |
- |
500 |
|
N/A |
| 20(Stability and mechanical hazards) |
- |
500 |
|
N/A |
| 21(Mechanical strength) |
- |
500 |
|
N/A |
| 22(Construction) |
- |
1000 |
|
N/A |
| 22.101(Construction) |
- |
500 |
|
N/A |
| 23(Internal wiring) |
- |
500 |
|
N/A |
| 24(Components) |
- |
500 |
|
N/A |
| 25("Supply connection and
external flexible cords") |
- |
500 |
|
N/A |
| 26("Terminals for external
conductors") |
- |
1000 |
|
N/A |
| 27(Provision for earthing) |
- |
1000 |
|
N/A |
| 28(Screws and connections) |
- |
500 |
|
N/A |
| 29("Clearances, creepage
distances and solid insulation") |
- |
500 |
|
N/A |
| 30(Resistance to heat and fire) |
- |
1000 |
|
N/A |
| 31(Resistance to rusting) |
- |
500 |
|
N/A |
| 32("Radiation, toxicity and similar
hazards") |
- |
0 |
|
N/A |
| Cl.19.11.4.1(Electrostatic discharges) |
- |
1000 |
|
N/A |
| Cl.19.11.4.2(Radiated fields) |
- |
0 |
|
N/A |
| Cl.19.11.4.3(Fast transient bursts) |
- |
0 |
|
N/A |
| Cl.19.11.4.4(Voltage surges) |
- |
1000 |
|
N/A |
| Cl.19.11.4.5(Injected currents) |
- |
0 |
|
N/A |
| Cl.19.11.4.6(Class 3 voltage dips and interruptions) |
- |
0 |
|
N/A |
| Cl.19.11.4.7(mains signals) |
- |
0 |
|
N/A |
| 7(Marking and instructions) |
- |
- |
|
- |
| 8(Protection against access to live parts) |
- |
- |
|
- |
| 10(Power input and current) |
- |
- |
|
- |
| 11(Heating) |
- |
- |
|
- |
| 13.1 &13.2(Leakage current test) |
- |
- |
|
- |
| 13.1 &13.3(Electric strength test) |
- |
- |
|
- |
| 14(Transient overvoltages) |
- |
- |
|
- |
| 15(Moisture resistance) |
- |
- |
|
- |
| 15.3(Moisture resistance) |
- |
- |
|
- |
| 15.101(Moisture resistance) |
- |
- |
|
- |
| 16.1 &16.2(Leakage current test) |
- |
- |
|
- |
| 16.1 & 16.3(Electric strength test) |
- |
- |
|
- |
| 17(Overload protection of transformers and associated circuits) |
- |
- |
|
- |
| 19.1 to 19.13, Table No. - 9(Abnormal operation) |
- |
- |
|
- |
| 19.101 to to 19.102(Abnormal operation) |
- |
- |
|
- |
| 20(Stability and mechanical hazards) |
- |
- |
|
- |
| 21(Mechanical strength) |
- |
- |
|
- |
| 22(Construction) |
- |
- |
|
- |
| 22.101(Construction) |
- |
- |
|
- |
| 23(Internal wiring) |
- |
- |
|
- |
| 24(Components) |
- |
- |
|
- |
| 25("Supply connection and
external flexible cords") |
- |
- |
|
- |
| 26("Terminals for external
conductors") |
- |
- |
|
- |
| 27(Provision for earthing) |
- |
- |
|
- |
| 28(Screws and connections) |
- |
- |
|
- |
| 29("Clearances, creepage
distances and solid insulation") |
- |
- |
|
- |
| 30(Resistance to heat and fire) |
- |
- |
|
- |
| 31(Resistance to rusting) |
- |
- |
|
- |
| 32("Radiation, toxicity and similar
hazards") |
- |
- |
|
- |
| Cl.19.11.4.1(Electrostatic discharges) |
- |
- |
|
- |
| Cl.19.11.4.2(Radiated fields) |
- |
- |
|
- |
| Cl.19.11.4.3(Fast transient bursts) |
- |
- |
|
- |
| Cl.19.11.4.4(Voltage surges) |
- |
- |
|
- |
| Cl.19.11.4.5(Injected currents) |
- |
- |
|
- |
| Cl.19.11.4.6(Class 3 voltage dips and interruptions) |
- |
- |
|
- |
| Cl.19.11.4.7(mains signals) |
- |
- |
|
- |
|
02 Sep, 2028 |
- Included w.e.f. 15.10.2025
Exclusion: "24 (Components)
32 (""Radiation, toxicity and similar hazards"")
Cl.19.11.4.2 (Radiated fields)
Cl.19.11.4.3 (Fast transient bursts)
Cl.19.11.4.5 (Injected currents)
Cl.19.11.4.6 (Class 3 voltage dips and interruptions)
Cl.19.11.4.7 (mains signals)
" |
| 19 |
IS 302 : Part 2 : Sec 6 (2009) |
Safety of household and similar electrical appliances: Part 2 particular requirements: Sec 6 cooking ranges, hobs, ovens and similar appliances (First Revision) |
-- |
14000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6.0(Classification) |
- |
250 |
|
N/A |
| 7.0(Marking and instructions) |
- |
500 |
|
N/A |
| 8.0(Protection against access to live part test) |
- |
500 |
|
N/A |
| 9.0(Starting of motor-operated appliances test) |
- |
0 |
|
N/A |
| 10.0(Power Input and current test) |
- |
500 |
|
N/A |
| 11.0(Heating test) |
- |
500 |
|
N/A |
| 13.0(Leakage current and electric strength test) |
- |
500 |
|
N/A |
| 14.0(Transient voltages) |
- |
500 |
|
N/A |
| 15.0(Moisture Resistance) |
- |
1000 |
|
N/A |
| 16.0(Leakage current and electric strength test) |
- |
500 |
|
N/A |
| 17.0(Overload protection of transformers test) |
- |
500 |
|
N/A |
| 18.0(Endurance test) |
- |
0 |
|
N/A |
| 19.0(Abnormal Operations) |
- |
500 |
|
N/A |
| 20.0(Stability and Mechanical Hazards) |
- |
500 |
|
N/A |
| 21.0(Mechanical Strength) |
- |
500 |
|
N/A |
| 22.0(Construction verification related tests) |
- |
1000 |
|
N/A |
| 23.0(Internal wiring) |
- |
500 |
|
N/A |
| 24.0(Components) |
- |
500 |
|
N/A |
| 25.0(Supply connections and External Flexible Cords) |
- |
500 |
|
N/A |
| 26.0(Terminal for External Conductors) |
- |
500 |
|
N/A |
| 27.0(Provision for Earthing) |
- |
500 |
|
N/A |
| 28.0(Screws and connections) |
- |
500 |
|
N/A |
| 29.0(Clearances and Creepage distances and solid insulation) |
- |
250 |
|
N/A |
| 30.0(Resistance to heat and fire) |
- |
250 |
|
N/A |
| 31.0(Resistance to rusting) |
- |
250 |
|
N/A |
| 32.0(Radiation, Toxicity and Similar hazards) |
- |
0 |
|
N/A |
| 19.11.4.1(Electrostatic discharges) |
- |
1000 |
|
N/A |
| 19.11.4.2(Radiated fields) |
- |
0 |
|
N/A |
| 19.11.4.3(Fast transient bursts) |
- |
0 |
|
N/A |
| 19.11.4.4(Surge immunity test) |
- |
1000 |
|
N/A |
| 19.11.4.5(Immunity to conducted discharges) |
- |
0 |
|
N/A |
| 19.11.4.6(Class 3 Voltage dips and interruptions) |
- |
0 |
|
N/A |
| 19.11.4.7(Harmonics) |
- |
0 |
|
N/A |
| 4(General Requirements) |
- |
0 |
|
N/A |
| 5(General condition for the tests) |
- |
0 |
|
N/A |
| 22.111(Pyrolytic self-cleaning) |
- |
500 |
|
N/A |
| 6.0(Classification) |
- |
0 |
|
N/A |
| 7.0(Marking and instructions) |
- |
0 |
|
N/A |
| 8.0(Protection against access to live part test) |
- |
0 |
|
N/A |
| 9.0(Starting of motor-operated appliances test) |
- |
0 |
|
N/A |
| 10.0(Power Input and current test) |
- |
0 |
|
N/A |
| 11.0(Heating test) |
- |
0 |
|
N/A |
| 13.0(Leakage current and electric strength test) |
- |
0 |
|
N/A |
| 14.0(Transient voltages) |
- |
0 |
|
N/A |
| 15.0(Moisture Resistance) |
- |
0 |
|
N/A |
| 16.0(Leakage current and electric strength test) |
- |
0 |
|
N/A |
| 17.0(Overload protection of transformers test) |
- |
0 |
|
N/A |
| 18.0(Endurance test) |
- |
0 |
|
N/A |
| 19.0(Abnormal Operations) |
- |
0 |
|
N/A |
| 20.0(Stability and Mechanical Hazards) |
- |
0 |
|
N/A |
| 21.0(Mechanical Strength) |
- |
0 |
|
N/A |
| 22.0(Construction verification related tests) |
- |
0 |
|
N/A |
| 23.0(Internal wiring) |
- |
0 |
|
N/A |
| 24.0(Components) |
- |
0 |
|
N/A |
| 25.0(Supply connections and External Flexible Cords) |
- |
0 |
|
N/A |
| 26.0(Terminal for External Conductors) |
- |
0 |
|
N/A |
| 27.0(Provision for Earthing) |
- |
0 |
|
N/A |
| 28.0(Screws and connections) |
- |
0 |
|
N/A |
| 29.0(Clearances and Creepage distances and solid insulation) |
- |
0 |
|
N/A |
| 30.0(Resistance to heat and fire) |
- |
0 |
|
N/A |
| 31.0(Resistance to rusting) |
- |
0 |
|
N/A |
| 32.0(Radiation, Toxicity and Similar hazards) |
- |
0 |
|
N/A |
| 19.11.4.1(Electrostatic discharges) |
- |
0 |
|
N/A |
| 19.11.4.2(Radiated fields) |
- |
0 |
|
N/A |
| 19.11.4.3(Fast transient bursts) |
- |
0 |
|
N/A |
| 19.11.4.4(Surge immunity test) |
- |
0 |
|
N/A |
| 19.11.4.5(Immunity to conducted discharges) |
- |
0 |
|
N/A |
| 19.11.4.6(Class 3 Voltage dips and interruptions) |
- |
0 |
|
N/A |
| 19.11.4.7(Harmonics) |
- |
0 |
|
N/A |
| 4(General Requirements) |
- |
0 |
|
N/A |
| 5(General condition for the tests) |
- |
0 |
|
N/A |
| 22.111(Pyrolytic self-cleaning) |
- |
0 |
|
N/A |
| 6.0(Classification) |
- |
- |
|
- |
| 7.0(Marking and instructions) |
- |
- |
|
- |
| 8.0(Protection against access to live part test) |
- |
- |
|
- |
| 9.0(Starting of motor-operated appliances test) |
- |
- |
|
- |
| 10.0(Power Input and current test) |
- |
- |
|
- |
| 11.0(Heating test) |
- |
- |
|
- |
| 13.0(Leakage current and electric strength test) |
- |
- |
|
- |
| 14.0(Transient voltages) |
- |
- |
|
- |
| 15.0(Moisture Resistance) |
- |
- |
|
- |
| 16.0(Leakage current and electric strength test) |
- |
- |
|
- |
| 17.0(Overload protection of transformers test) |
- |
- |
|
- |
| 18.0(Endurance test) |
- |
- |
|
- |
| 19.0(Abnormal Operations) |
- |
- |
|
- |
| 20.0(Stability and Mechanical Hazards) |
- |
- |
|
- |
| 21.0(Mechanical Strength) |
- |
- |
|
- |
| 22.0(Construction verification related tests) |
- |
- |
|
- |
| 23.0(Internal wiring) |
- |
- |
|
- |
| 24.0(Components) |
- |
- |
|
- |
| 25.0(Supply connections and External Flexible Cords) |
- |
- |
|
- |
| 26.0(Terminal for External Conductors) |
- |
- |
|
- |
| 27.0(Provision for Earthing) |
- |
- |
|
- |
| 28.0(Screws and connections) |
- |
- |
|
- |
| 29.0(Clearances and Creepage distances and solid insulation) |
- |
- |
|
- |
| 30.0(Resistance to heat and fire) |
- |
- |
|
- |
| 31.0(Resistance to rusting) |
- |
- |
|
- |
| 32.0(Radiation, Toxicity and Similar hazards) |
- |
- |
|
- |
| 19.11.4.1(Electrostatic discharges) |
- |
- |
|
- |
| 19.11.4.2(Radiated fields) |
- |
- |
|
- |
| 19.11.4.3(Fast transient bursts) |
- |
- |
|
- |
| 19.11.4.4(Surge immunity test) |
- |
- |
|
- |
| 19.11.4.5(Immunity to conducted discharges) |
- |
- |
|
- |
| 19.11.4.6(Class 3 Voltage dips and interruptions) |
- |
- |
|
- |
| 19.11.4.7(Harmonics) |
- |
- |
|
- |
| 4(General Requirements) |
- |
- |
|
- |
| 5(General condition for the tests) |
- |
- |
|
- |
| 22.111(Pyrolytic self-cleaning) |
- |
- |
|
- |
|
02 Sep, 2028 |
- Included w.e.f. 15.10.2025
Exclusion: "19.11.4.2 (Radiated fields)
19.11.4.3 (Fast transient bursts)
19.11.4.5 (Immunity to conducted discharges)
19.11.4.6 (Class 3 Voltage dips and interruptions)
19.11.4.7 (Harmonics)
24.0 (Components)
32.0 (Radiation, Toxicity and Similar hazards)
" |
| 20 |
IS 302 : Part 2 : Sec 42 (2024) |
Household and Similar Electrical Appliances�Safety Part 2 Particular Requirements Section 42 Commercial electric forced convection ovens, steam cookers and steam-convection ovens |
-- |
30000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 7(Marking and instructions) |
- |
500 |
|
N/A |
| 8(Protection against access to live parts) |
- |
500 |
|
N/A |
| 10(Power input and current) |
- |
1000 |
|
N/A |
| 11(Heating) |
- |
1000 |
|
N/A |
| 13.1 &13.2(Leakage current test) |
- |
1000 |
|
N/A |
| 13.1 &13.3(Electric strength test) |
- |
1000 |
|
N/A |
| 14(Transient overvoltages) |
- |
1000 |
|
N/A |
| 15(Moisture resistance) |
- |
1000 |
|
N/A |
| 15.3(Moisture resistance) |
- |
500 |
|
N/A |
| 15.101(Moisture resistance) |
- |
500 |
|
N/A |
| 16.1 &16.2(Leakage current test) |
- |
1000 |
|
N/A |
| 16.1 & 16.3(Electric strength test) |
- |
1000 |
|
N/A |
| 17(Overload protection of transformers and associated circuits) |
- |
1000 |
|
N/A |
| 19.1 to 19.13, Table No. - 9(Abnormal operation) |
- |
500 |
|
N/A |
| 19.101(Abnormal operation) |
- |
500 |
|
N/A |
| 20.1(Stability and mechanical hazards) |
- |
500 |
|
N/A |
| 20.2(Stability and mechanical hazards) |
- |
500 |
|
N/A |
| 20.101(Stability and mechanical hazards) |
- |
500 |
|
N/A |
| 20.102(Stability and mechanical hazards) |
- |
500 |
|
N/A |
| 21(Mechanical strength) |
- |
500 |
|
N/A |
| 21.101(Mechanical strength) |
- |
500 |
|
N/A |
| 22(Construction) |
- |
500 |
|
N/A |
| 22.101(Construction) |
- |
250 |
|
N/A |
| 22.102(Construction) |
- |
250 |
|
N/A |
| 22.103(Construction) |
- |
250 |
|
N/A |
| 22.104(Construction) |
- |
250 |
|
N/A |
| 22.105(Construction) |
- |
250 |
|
N/A |
| 22.106(Construction) |
- |
250 |
|
N/A |
| 22.107(Construction) |
- |
250 |
|
N/A |
| 22.108(Construction) |
- |
250 |
|
N/A |
| 22.109(Construction) |
- |
250 |
|
N/A |
| 22.109(Construction) |
- |
250 |
|
N/A |
| 22.110(Construction) |
- |
250 |
|
N/A |
| 22.111(Construction) |
- |
250 |
|
N/A |
| 22.112(Construction) |
- |
250 |
|
N/A |
| 22.113(Construction) |
- |
250 |
|
N/A |
| 22.114(Construction) |
- |
250 |
|
N/A |
| 22.115(Construction) |
- |
250 |
|
N/A |
| 22.116(Construction) |
- |
250 |
|
N/A |
| 22.117(Construction) |
- |
250 |
|
N/A |
| 22.118(Construction) |
- |
250 |
|
N/A |
| 22.119(Construction) |
- |
250 |
|
N/A |
| 23(Internal wiring) |
- |
1000 |
|
N/A |
| 24(Components) |
- |
500 |
|
N/A |
| 25("Supply connection and
external flexible cords") |
- |
1000 |
|
N/A |
| 26("Terminals for external
conductors") |
- |
1000 |
|
N/A |
| 27(Provision for earthing) |
- |
1000 |
|
N/A |
| 28(Screws and connections) |
- |
1000 |
|
N/A |
| 29("Clearances, creepage
distances and solid insulation") |
- |
1000 |
|
N/A |
| 30(Resistance to heat and fire) |
- |
1000 |
|
N/A |
| 30.101(Resistance to heat and fire) |
- |
1000 |
|
N/A |
| 31(Resistance to rusting) |
- |
1000 |
|
N/A |
| 32("Radiation, toxicity and similar
hazards") |
- |
0 |
|
N/A |
| 7(Marking and instructions) |
- |
- |
|
- |
| 8(Protection against access to live parts) |
- |
- |
|
- |
| 10(Power input and current) |
- |
- |
|
- |
| 11(Heating) |
- |
- |
|
- |
| 13.1 &13.2(Leakage current test) |
- |
- |
|
- |
| 13.1 &13.3(Electric strength test) |
- |
- |
|
- |
| 14(Transient overvoltages) |
- |
- |
|
- |
| 15(Moisture resistance) |
- |
- |
|
- |
| 15.3(Moisture resistance) |
- |
- |
|
- |
| 15.101(Moisture resistance) |
- |
- |
|
- |
| 16.1 &16.2(Leakage current test) |
- |
- |
|
- |
| 16.1 & 16.3(Electric strength test) |
- |
- |
|
- |
| 17(Overload protection of transformers and associated circuits) |
- |
- |
|
- |
| 19.1 to 19.13, Table No. - 9(Abnormal operation) |
- |
- |
|
- |
| 19.101(Abnormal operation) |
- |
- |
|
- |
| 20.1(Stability and mechanical hazards) |
- |
- |
|
- |
| 20.2(Stability and mechanical hazards) |
- |
- |
|
- |
| 20.101(Stability and mechanical hazards) |
- |
- |
|
- |
| 20.102(Stability and mechanical hazards) |
- |
- |
|
- |
| 21(Mechanical strength) |
- |
- |
|
- |
| 21.101(Mechanical strength) |
- |
- |
|
- |
| 22(Construction) |
- |
- |
|
- |
| 22.101(Construction) |
- |
- |
|
- |
| 22.102(Construction) |
- |
- |
|
- |
| 22.103(Construction) |
- |
- |
|
- |
| 22.104(Construction) |
- |
- |
|
- |
| 22.105(Construction) |
- |
- |
|
- |
| 22.106(Construction) |
- |
- |
|
- |
| 22.107(Construction) |
- |
- |
|
- |
| 22.108(Construction) |
- |
- |
|
- |
| 22.109(Construction) |
- |
- |
|
- |
| 22.109(Construction) |
- |
- |
|
- |
| 22.110(Construction) |
- |
- |
|
- |
| 22.111(Construction) |
- |
- |
|
- |
| 22.112(Construction) |
- |
- |
|
- |
| 22.113(Construction) |
- |
- |
|
- |
| 22.114(Construction) |
- |
- |
|
- |
| 22.115(Construction) |
- |
- |
|
- |
| 22.116(Construction) |
- |
- |
|
- |
| 22.117(Construction) |
- |
- |
|
- |
| 22.118(Construction) |
- |
- |
|
- |
| 22.119(Construction) |
- |
- |
|
- |
| 23(Internal wiring) |
- |
- |
|
- |
| 24(Components) |
- |
- |
|
- |
| 25("Supply connection and
external flexible cords") |
- |
- |
|
- |
| 26("Terminals for external
conductors") |
- |
- |
|
- |
| 27(Provision for earthing) |
- |
- |
|
- |
| 28(Screws and connections) |
- |
- |
|
- |
| 29("Clearances, creepage
distances and solid insulation") |
- |
- |
|
- |
| 30(Resistance to heat and fire) |
- |
- |
|
- |
| 30.101(Resistance to heat and fire) |
- |
- |
|
- |
| 31(Resistance to rusting) |
- |
- |
|
- |
| 32("Radiation, toxicity and similar
hazards") |
- |
- |
|
- |
|
02 Sep, 2028 |
- Included w.e.f 19.12.2025
"32 (RADIATION HAZARDS)
Cl-19.11.4.2 (Radiated Fields)
Cl-19.11.4.3 (Fast transient bursts)
Cl-19.11.4.5 (Immunity to conducted discharge)
Cl-19.11.4.6 (Voltage dips and interruptions)
Cl-19.11.4.7 (Harmonics)
24 (COMPONENTS)" |
| 21 |
IS 302 : Part 2 : Sec 12 (1993) |
Safety of household and similar electrical appliances - Specification: Part 2 particular requirements: Sec 12 warming plates and similar appliances |
-- |
45000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 5(Rating) |
- |
500 |
|
N/A |
| 6(Classification) |
- |
500 |
|
N/A |
| 7(Marking) |
- |
1000 |
|
N/A |
| 8(Protection against Access to Live Parts) |
- |
2000 |
|
N/A |
| 9(Starting Of Motor Operated Appliances) |
- |
0 |
|
N/A |
| 10("Power Input
& Current") |
- |
2000 |
|
N/A |
| 11(Temperature Rise/ Heating) |
- |
2000 |
|
N/A |
| 12(Operation Under Overload Conditions of Appliances with heating Element) |
- |
0 |
|
N/A |
| 13(Leakage Current and Electric Strength at Operating Temperature) |
- |
2000 |
|
N/A |
| 14("Radio and Television Interference Suppression / Transient Over Voltage
") |
- |
2000 |
|
N/A |
| 15(Moisture Resistance) |
- |
3000 |
|
N/A |
| 16(Insulation Resistance and Electric Strength/ Leakage Current and Electric Strength) |
- |
2000 |
|
N/A |
| 17(Overload Protection/ Overload Protection of Transformers & Associated Circuits) |
- |
2000 |
|
N/A |
| 18(Endurance) |
- |
0 |
|
N/A |
| 19(Abnormal Operation) |
- |
2000 |
|
N/A |
| 20(Stability & Mechanical Hazards) |
- |
2000 |
|
N/A |
| 21(Mechanical strength) |
- |
1500 |
|
N/A |
| 22(Construction) |
- |
2500 |
|
N/A |
| 23(Internal Wiring) |
- |
1000 |
|
N/A |
| 24(Components) |
- |
1000 |
|
N/A |
| 25(Supply Connection & External Flexible Cords) |
- |
2000 |
|
N/A |
| 26(Terminals For External Conductors) |
- |
2000 |
|
N/A |
| 27(Provision For Earthing) |
- |
2000 |
|
N/A |
| 28(Screws & Connections) |
- |
2000 |
|
N/A |
| 29(Clearances, Creepage Distances & Solid Insulation) |
- |
1000 |
|
N/A |
| 30(Resistance to Heat & Fire) |
- |
2000 |
|
N/A |
| 31(Resistance to Rusting) |
- |
1000 |
|
N/A |
| 32(Radiation hazards) |
- |
0 |
|
N/A |
| 19.11.4.1(Electrostatic discharges) |
- |
2000 |
|
N/A |
| 19.11.4.2(Radiated fields) |
- |
0 |
|
N/A |
| 19.11.4.3(Fast transient bursts) |
- |
0 |
|
N/A |
| 19.11.4.4(Surge immunity test) |
- |
2000 |
|
N/A |
| 19.11.4.5(Immunity to conducted discharges) |
- |
0 |
|
N/A |
| 19.11.4.6(Class 3 Voltage dips and interruptions) |
- |
0 |
|
N/A |
| 19.11.4.7(Harmonics) |
- |
0 |
|
N/A |
| 5(Rating) |
- |
- |
|
- |
| 6(Classification) |
- |
- |
|
- |
| 7(Marking) |
- |
- |
|
- |
| 8(Protection against Access to Live Parts) |
- |
- |
|
- |
| 9(Starting Of Motor Operated Appliances) |
- |
- |
|
- |
| 10("Power Input
& Current") |
- |
- |
|
- |
| 11(Temperature Rise/ Heating) |
- |
- |
|
- |
| 12(Operation Under Overload Conditions of Appliances with heating Element) |
- |
- |
|
- |
| 13(Leakage Current and Electric Strength at Operating Temperature) |
- |
- |
|
- |
| 14("Radio and Television Interference Suppression / Transient Over Voltage
") |
- |
- |
|
- |
| 15(Moisture Resistance) |
- |
- |
|
- |
| 16(Insulation Resistance and Electric Strength/ Leakage Current and Electric Strength) |
- |
- |
|
- |
| 17(Overload Protection/ Overload Protection of Transformers & Associated Circuits) |
- |
- |
|
- |
| 18(Endurance) |
- |
- |
|
- |
| 19(Abnormal Operation) |
- |
- |
|
- |
| 20(Stability & Mechanical Hazards) |
- |
- |
|
- |
| 21(Mechanical strength) |
- |
- |
|
- |
| 22(Construction) |
- |
- |
|
- |
| 23(Internal Wiring) |
- |
- |
|
- |
| 24(Components) |
- |
- |
|
- |
| 25(Supply Connection & External Flexible Cords) |
- |
- |
|
- |
| 26(Terminals For External Conductors) |
- |
- |
|
- |
| 27(Provision For Earthing) |
- |
- |
|
- |
| 28(Screws & Connections) |
- |
- |
|
- |
| 29(Clearances, Creepage Distances & Solid Insulation) |
- |
- |
|
- |
| 30(Resistance to Heat & Fire) |
- |
- |
|
- |
| 31(Resistance to Rusting) |
- |
- |
|
- |
| 32(Radiation hazards) |
- |
- |
|
- |
| 19.11.4.1(Electrostatic discharges) |
- |
- |
|
- |
| 19.11.4.2(Radiated fields) |
- |
- |
|
- |
| 19.11.4.3(Fast transient bursts) |
- |
- |
|
- |
| 19.11.4.4(Surge immunity test) |
- |
- |
|
- |
| 19.11.4.5(Immunity to conducted discharges) |
- |
- |
|
- |
| 19.11.4.6(Class 3 Voltage dips and interruptions) |
- |
- |
|
- |
| 19.11.4.7(Harmonics) |
- |
- |
|
- |
|
02 Sep, 2028 |
- Included w.e.f 29.10.2025
Exclusion: 19.11.4.2 (Radiated fields), 19.11.4.3 (Fast transient bursts) , 19.11.4.5 (Immunity to conducted discharges) , 19.11.4.6 (Class 3 Voltage dips and interruptions) , 19.11.4.7 (Harmonics) , 24 (Component) |
| 22 |
IS 302 : Part 2 : Sec 23 (2009) |
Safety of household and similar electrical appliances: Part 2 particular requirements: Sec 23 appliances for skin or hair care (First Revision) |
-- |
20000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 32(Radiation ,Toxicity and similar hazards) |
- |
0 |
|
N/A |
| 31(Resistance to Rusting) |
- |
1000 |
|
N/A |
| 30(Resistance to Heat & Fire) |
- |
1000 |
|
N/A |
| 29(Clearances, Creepage Distances & Solid Insulation) |
- |
1000 |
|
N/A |
| 28(Screws & Connection) |
- |
1000 |
|
N/A |
| 27(Provision For Earthing) |
- |
500 |
|
N/A |
| 26(Terminals For External Conductors) |
- |
500 |
|
N/A |
| 25(Supply Connection & External Flexible Cables and Cords) |
- |
1000 |
|
N/A |
| 24(Component) |
- |
500 |
|
N/A |
| 23(Internal wiring) |
- |
500 |
|
N/A |
| 22(Construction) |
- |
1000 |
|
N/A |
| 21(Mechanical strength) |
- |
500 |
|
N/A |
| 20(Stability & Mechanical Hazards) |
- |
500 |
|
N/A |
| 19(Abnormal Operation) |
- |
1000 |
|
N/A |
| 18(Endurance) |
- |
0 |
|
N/A |
| 17(Overload Protection/ Overload Protection of Transformers & Associated Circuits) |
- |
1000 |
|
N/A |
| 16(Leakage Current and Electric Strength) |
- |
1000 |
|
N/A |
| 15(Moisture Resistance) |
- |
1000 |
|
N/A |
| 14(Transient Over Voltage) |
- |
1000 |
|
N/A |
| 13(Leakage Current and Electric Strength at Operating Temperature) |
- |
500 |
|
N/A |
| 11(Temperature Rise/Heating) |
- |
500 |
|
N/A |
| 10(Power Input
& Current) |
- |
500 |
|
N/A |
| 9(Starting Of Motor Operated Appliances) |
- |
0 |
|
N/A |
| 8(Protection against Electric Shock/ Protection against Access to Live Parts) |
- |
500 |
|
N/A |
| 7(Marking/ Marking & Instructions) |
- |
500 |
|
N/A |
| 6(Classification) |
- |
500 |
|
N/A |
| 22.32(CONSTRUCTION) |
- |
1000 |
|
N/A |
| 19.11.4.1(Electrostatic discharges) |
- |
1000 |
|
N/A |
| 19.11.4.2(Radiated fields) |
- |
0 |
|
N/A |
| 19.11.4.3(Fast transient bursts) |
- |
0 |
|
N/A |
| 19.11.4.4(Surge immunity test) |
- |
1000 |
|
N/A |
| 19.11.4.5(Immunity to conducted discharges) |
- |
0 |
|
N/A |
| 19.11.4.6(Class 3 Voltage dips and interruptions) |
- |
0 |
|
N/A |
| 19.11.4.7(Harmonics) |
- |
0 |
|
N/A |
| 32(Radiation ,Toxicity and similar hazards) |
- |
- |
|
- |
| 31(Resistance to Rusting) |
- |
- |
|
- |
| 30(Resistance to Heat & Fire) |
- |
- |
|
- |
| 29(Clearances, Creepage Distances & Solid Insulation) |
- |
- |
|
- |
| 28(Screws & Connection) |
- |
- |
|
- |
| 27(Provision For Earthing) |
- |
- |
|
- |
| 26(Terminals For External Conductors) |
- |
- |
|
- |
| 25(Supply Connection & External Flexible Cables and Cords) |
- |
- |
|
- |
| 24(Component) |
- |
- |
|
- |
| 23(Internal wiring) |
- |
- |
|
- |
| 22(Construction) |
- |
- |
|
- |
| 21(Mechanical strength) |
- |
- |
|
- |
| 20(Stability & Mechanical Hazards) |
- |
- |
|
- |
| 19(Abnormal Operation) |
- |
- |
|
- |
| 18(Endurance) |
- |
- |
|
- |
| 17(Overload Protection/ Overload Protection of Transformers & Associated Circuits) |
- |
- |
|
- |
| 16(Leakage Current and Electric Strength) |
- |
- |
|
- |
| 15(Moisture Resistance) |
- |
- |
|
- |
| 14(Transient Over Voltage) |
- |
- |
|
- |
| 13(Leakage Current and Electric Strength at Operating Temperature) |
- |
- |
|
- |
| 11(Temperature Rise/Heating) |
- |
- |
|
- |
| 10(Power Input
& Current) |
- |
- |
|
- |
| 9(Starting Of Motor Operated Appliances) |
- |
- |
|
- |
| 8(Protection against Electric Shock/ Protection against Access to Live Parts) |
- |
- |
|
- |
| 7(Marking/ Marking & Instructions) |
- |
- |
|
- |
| 6(Classification) |
- |
- |
|
- |
| 22.32(CONSTRUCTION) |
- |
- |
|
- |
| 19.11.4.1(Electrostatic discharges) |
- |
- |
|
- |
| 19.11.4.2(Radiated fields) |
- |
- |
|
- |
| 19.11.4.3(Fast transient bursts) |
- |
- |
|
- |
| 19.11.4.4(Surge immunity test) |
- |
- |
|
- |
| 19.11.4.5(Immunity to conducted discharges) |
- |
- |
|
- |
| 19.11.4.6(Class 3 Voltage dips and interruptions) |
- |
- |
|
- |
| 19.11.4.7(Harmonics) |
- |
- |
|
- |
|
02 Sep, 2028 |
- Included w.e.f 29.10.2025
Exclusion: 19.11.4.2 (Radiated fields), 19.11.4.3 (Fast transient bursts) , 19.11.4.5 (Immunity to conducted discharges) , 19.11.4.6 (Class 3 Voltage dips and interruptions) , 19.11.4.7 (Harmonics) , 24 (Component) |
| 23 |
IS 302 : Part 2 : Sec 45 (1994) |
Safety of household and similar electrical appliances: Part 2 particular requirements: Sec 45 electric heating tools |
-- |
34000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 5(Rating) |
- |
500 |
|
N/A |
| 6(Classification) |
- |
500 |
|
N/A |
| 7(Marking) |
- |
1000 |
|
N/A |
| 8(Protection against Access to Live Parts) |
- |
1000 |
|
N/A |
| 9(Starting Of Motor Operated Appliances) |
- |
0 |
|
N/A |
| 10("Power Input
& Current") |
- |
1000 |
|
N/A |
| 11(Temperature Rise/ Heating) |
- |
2000 |
|
N/A |
| 12(Operation Under Overload Condition) |
- |
2000 |
|
N/A |
| 13(Electric Insulation at Operating Temperature) |
- |
1000 |
|
N/A |
| 14("Radio and Television Interference Suppression / Transient Over Voltage
") |
- |
1000 |
|
N/A |
| 15(Moisture Resistance) |
- |
2000 |
|
N/A |
| 16(Insulation Resistance and Electric Strength/ Leakage Current and Electric Strength (After Humidity Treatment)) |
- |
1000 |
|
N/A |
| 17(Overload Protection/ Overload Protection of Transformers & Associated Circuits) |
- |
1000 |
|
N/A |
| 18(Endurance) |
- |
0 |
|
N/A |
| 19(Abnormal Operation) |
- |
1000 |
|
N/A |
| 20(Stability & Mechanical Hazards) |
- |
1000 |
|
N/A |
| 21(Mechanical strength) |
- |
1000 |
|
N/A |
| 22(Construction) |
- |
2000 |
|
N/A |
| 23(Internal Wiring) |
- |
1000 |
|
N/A |
| 24(Components) |
- |
1000 |
|
N/A |
| 25(Supply Connection & External Flexible Cords) |
- |
1000 |
|
N/A |
| 26(Terminals For External Conductors) |
- |
1000 |
|
N/A |
| 27(Provision For Earthing) |
- |
2000 |
|
N/A |
| 28(Screws & Connections) |
- |
1000 |
|
N/A |
| 29(Creepage Distances & Clearances) |
- |
1000 |
|
N/A |
| 30(Resistance to Heat, Fire and Tracking) |
- |
2000 |
|
N/A |
| 31(Radiation hazards) |
- |
0 |
|
N/A |
| XXV of Table 101(Resistance to Rusting) |
- |
1000 |
|
N/A |
| 4(General Requirement) |
- |
0 |
|
N/A |
| 19.11.4.7(Harmonics) |
- |
0 |
|
N/A |
| 19.11.4.6(Class 3 Voltage dips and interruptions) |
- |
0 |
|
N/A |
| 19.11.4.5(Immunity to conducted discharges) |
- |
0 |
|
N/A |
| 19.11.4.4(Surge immunity test) |
- |
2000 |
|
N/A |
| 19.11.4.3(Fast transient bursts) |
- |
0 |
|
N/A |
| 19.11.4.2(Radiated fields) |
- |
0 |
|
N/A |
| 19.11.4.1(Electrostatic discharges) |
- |
2000 |
|
N/A |
| 5(Rating) |
- |
- |
|
- |
| 6(Classification) |
- |
- |
|
- |
| 7(Marking) |
- |
- |
|
- |
| 8(Protection against Access to Live Parts) |
- |
- |
|
- |
| 9(Starting Of Motor Operated Appliances) |
- |
- |
|
- |
| 10("Power Input
& Current") |
- |
- |
|
- |
| 11(Temperature Rise/ Heating) |
- |
- |
|
- |
| 12(Operation Under Overload Condition) |
- |
- |
|
- |
| 13(Electric Insulation at Operating Temperature) |
- |
- |
|
- |
| 14("Radio and Television Interference Suppression / Transient Over Voltage
") |
- |
- |
|
- |
| 15(Moisture Resistance) |
- |
- |
|
- |
| 16(Insulation Resistance and Electric Strength/ Leakage Current and Electric Strength (After Humidity Treatment)) |
- |
- |
|
- |
| 17(Overload Protection/ Overload Protection of Transformers & Associated Circuits) |
- |
- |
|
- |
| 18(Endurance) |
- |
- |
|
- |
| 19(Abnormal Operation) |
- |
- |
|
- |
| 20(Stability & Mechanical Hazards) |
- |
- |
|
- |
| 21(Mechanical strength) |
- |
- |
|
- |
| 22(Construction) |
- |
- |
|
- |
| 23(Internal Wiring) |
- |
- |
|
- |
| 24(Components) |
- |
- |
|
- |
| 25(Supply Connection & External Flexible Cords) |
- |
- |
|
- |
| 26(Terminals For External Conductors) |
- |
- |
|
- |
| 27(Provision For Earthing) |
- |
- |
|
- |
| 28(Screws & Connections) |
- |
- |
|
- |
| 29(Creepage Distances & Clearances) |
- |
- |
|
- |
| 30(Resistance to Heat, Fire and Tracking) |
- |
- |
|
- |
| 31(Radiation hazards) |
- |
- |
|
- |
| XXV of Table 101(Resistance to Rusting) |
- |
- |
|
- |
| 4(General Requirement) |
- |
- |
|
- |
| 19.11.4.7(Harmonics) |
- |
- |
|
- |
| 19.11.4.6(Class 3 Voltage dips and interruptions) |
- |
- |
|
- |
| 19.11.4.5(Immunity to conducted discharges) |
- |
- |
|
- |
| 19.11.4.4(Surge immunity test) |
- |
- |
|
- |
| 19.11.4.3(Fast transient bursts) |
- |
- |
|
- |
| 19.11.4.2(Radiated fields) |
- |
- |
|
- |
| 19.11.4.1(Electrostatic discharges) |
- |
- |
|
- |
|
02 Sep, 2028 |
- Included w.e.f 07.11.2025
Exclusion : 19.11.4.2 (Radiated fields), 19.11.4.3 (Fast transient bursts), 19.11.4.5 (Immunity to conducted discharges), 19.11.4.6 (Class 3 Voltage dips and interruptions), 19.11.4.7 (Harmonics), 24 (Components), 32 (Radiation hazards) |
| 24 |
IS 302 : Part 2 : Sec 203 (1994) |
Safety of household and similar electrical appliances: Part 2 particular requirements: Sec 203 electric call bells and buzzers for indoor use |
-- |
21000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 5(Rating) |
- |
0 |
|
N/A |
| 6(Classification) |
- |
500 |
|
N/A |
| 7(Marking) |
- |
500 |
|
N/A |
| 8(Protection against Access to Live Parts) |
- |
500 |
|
N/A |
| 9(Starting Of Motor Operated Appliances) |
- |
0 |
|
N/A |
| 10("Power Input
& Current") |
- |
500 |
|
N/A |
| 11(Temperature Rise/ Heating) |
- |
1000 |
|
N/A |
| 12(Operation Under Overload Conditions of Appliances with heating Element) |
- |
1000 |
|
N/A |
| 13(Leakage Current and Electric Strength at Operating Temperature) |
- |
500 |
|
N/A |
| 14("Radio and Television Interference Suppression / Transient Over Voltage
") |
- |
500 |
|
N/A |
| 15(Moisture Resistance) |
- |
1000 |
|
N/A |
| 16(Leakage Current and Electric Strength/ Insulation Resistance and Electric Strength (After Humidity treatment)) |
- |
1000 |
|
N/A |
| 17(Overload Protection/ Overload Protection of Transformers & Associated Circuits) |
- |
1000 |
|
N/A |
| 18(Endurance) |
- |
0 |
|
N/A |
| 19(Abnormal Operation) |
- |
1000 |
|
N/A |
| 20(Stability & Mechanical Hazards) |
- |
1000 |
|
N/A |
| 21(Mechanical strength) |
- |
1000 |
|
N/A |
| 22(Construction) |
- |
1000 |
|
N/A |
| 23(Internal Wiring) |
- |
1000 |
|
N/A |
| 24(Components) |
- |
1000 |
|
N/A |
| 25(Supply Connection & External Flexible Cords) |
- |
1000 |
|
N/A |
| 26(Terminals For External Conductors) |
- |
1000 |
|
N/A |
| 27(Provision For Earthing) |
- |
1000 |
|
N/A |
| 28(Screws & Connections) |
- |
500 |
|
N/A |
| 29(Clearances, Creepage Distances & Solid Insulation) |
- |
500 |
|
N/A |
| 30(Resistance to Heat & Fire) |
- |
500 |
|
N/A |
| 31(Resistance to Rusting) |
- |
500 |
|
N/A |
| 32(Radiation hazards) |
- |
0 |
|
N/A |
| Cl 19.11.4.1(Electrostatic discharges) |
- |
1000 |
|
N/A |
| Cl 19.11.4.2(Radiated fields) |
- |
0 |
|
N/A |
| Cl 19.11.4.3(Fast transient bursts) |
- |
0 |
|
N/A |
| Cl 19.11.4.4(Surge immunity test) |
- |
1000 |
|
N/A |
| Cl 19.11.4.5(Immunity to conducted discharges) |
- |
0 |
|
N/A |
| Cl 19.11.4.6(Class 3 Voltage dips and interruptions) |
- |
0 |
|
N/A |
| Cl 19.11.4.7(Harmonics) |
- |
0 |
|
N/A |
| 5(Rating) |
- |
- |
|
- |
| 6(Classification) |
- |
- |
|
- |
| 7(Marking) |
- |
- |
|
- |
| 8(Protection against Access to Live Parts) |
- |
- |
|
- |
| 9(Starting Of Motor Operated Appliances) |
- |
- |
|
- |
| 10("Power Input
& Current") |
- |
- |
|
- |
| 11(Temperature Rise/ Heating) |
- |
- |
|
- |
| 12(Operation Under Overload Conditions of Appliances with heating Element) |
- |
- |
|
- |
| 13(Leakage Current and Electric Strength at Operating Temperature) |
- |
- |
|
- |
| 14("Radio and Television Interference Suppression / Transient Over Voltage
") |
- |
- |
|
- |
| 15(Moisture Resistance) |
- |
- |
|
- |
| 16(Leakage Current and Electric Strength/ Insulation Resistance and Electric Strength (After Humidity treatment)) |
- |
- |
|
- |
| 17(Overload Protection/ Overload Protection of Transformers & Associated Circuits) |
- |
- |
|
- |
| 18(Endurance) |
- |
- |
|
- |
| 19(Abnormal Operation) |
- |
- |
|
- |
| 20(Stability & Mechanical Hazards) |
- |
- |
|
- |
| 21(Mechanical strength) |
- |
- |
|
- |
| 22(Construction) |
- |
- |
|
- |
| 23(Internal Wiring) |
- |
- |
|
- |
| 24(Components) |
- |
- |
|
- |
| 25(Supply Connection & External Flexible Cords) |
- |
- |
|
- |
| 26(Terminals For External Conductors) |
- |
- |
|
- |
| 27(Provision For Earthing) |
- |
- |
|
- |
| 28(Screws & Connections) |
- |
- |
|
- |
| 29(Clearances, Creepage Distances & Solid Insulation) |
- |
- |
|
- |
| 30(Resistance to Heat & Fire) |
- |
- |
|
- |
| 31(Resistance to Rusting) |
- |
- |
|
- |
| 32(Radiation hazards) |
- |
- |
|
- |
| Cl 19.11.4.1(Electrostatic discharges) |
- |
- |
|
- |
| Cl 19.11.4.2(Radiated fields) |
- |
- |
|
- |
| Cl 19.11.4.3(Fast transient bursts) |
- |
- |
|
- |
| Cl 19.11.4.4(Surge immunity test) |
- |
- |
|
- |
| Cl 19.11.4.5(Immunity to conducted discharges) |
- |
- |
|
- |
| Cl 19.11.4.6(Class 3 Voltage dips and interruptions) |
- |
- |
|
- |
| Cl 19.11.4.7(Harmonics) |
- |
- |
|
- |
|
02 Sep, 2028 |
- Included w.e.f 03.11.2025
Exclusion: Cl 19.11.4.2 (Radiated fields), Cl 19.11.4.3 (Fast transient bursts) , Cl 19.11.4.5 (Immunity to conducted discharges), Cl 19.11.4.6 (Class 3 Voltage dips and interruptions), Cl 19.11.4.7 (Harmonics), 24 (Components), 32 (Radiation hazards) |
| 25 |
IS 302 : Part 2 : Sec 32 (1994) |
Safety of household and similar electrical appliances: Part 2 particular requirements: Sec 32 massage appliances |
-- |
38000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl. 32 302-2-32 : 1994(Radiation Hazards) |
- |
0 |
|
N/A |
| Cl. 31 302-2-32 : 1994(Resistance to Rusting) |
- |
1000 |
|
N/A |
| Cl. 30 302-2-32 : 1994(Resistance to Heat Fire & Tracking ) |
- |
1000 |
|
N/A |
| Cl. 29 302-2-32 : 1994(Clearances, Creepage Distances & Solid insulation ) |
- |
1000 |
|
N/A |
| Cl. 28 302-2-32 : 1994(Screws & Connections) |
- |
1000 |
|
N/A |
| Cl. 27 302-2-32 : 1994(Provision for Earthing ) |
- |
2000 |
|
N/A |
| Cl. 26 302-2-32 : 1994(Terminals for External conductors ) |
- |
1000 |
|
N/A |
| Cl. 25 302-2-32 : 1994(Supply Connection & External Flexible Cords) |
- |
2000 |
|
N/A |
| Cl. 24 302-2-32 : 1994(Components) |
- |
1000 |
|
N/A |
| Cl. 23 302-2-32 : 1994(Internal Wiring) |
- |
2000 |
|
N/A |
| Cl. 22 302-2-32 : 1994(Construction ) |
- |
3000 |
|
N/A |
| Cl. 21 302-2-32 : 1994(Mechanical strength) |
- |
2000 |
|
N/A |
| Cl. 20 302-2-32 : 1994(Stability & Mechanical Hazards) |
- |
2000 |
|
N/A |
| Cl. 19 302-2-32 : 1994(Abnormal Operation ) |
- |
3000 |
|
N/A |
| Cl. 18 302-2-32 : 1994(Endurance) |
- |
0 |
|
N/A |
| Cl. 17 302-2-32 : 1994(Overload Protection of Transformers and Associated Circuit) |
- |
2000 |
|
N/A |
| Cl. 16 302-2-32 : 1994(Leakage Current & Electric Strength at Operating Temperature (After Humidity Treatment)) |
- |
2000 |
|
N/A |
| Cl. 15 302-2-32: 1994(Moisture Resistance Test ) |
- |
2000 |
|
N/A |
| Cl. 14 302-2-32 : 1994(Radio and television interference suppression / Transient over voltages) |
- |
1000 |
|
N/A |
| Cl. 13 302-2-32 : 1994(Leakage Current & Electric Strength at Operating Temperature) |
- |
1000 |
|
N/A |
| Cl. 11 302-2-32 : 1994(Temperature Rise) |
- |
2000 |
|
N/A |
| Cl. 10 302-2-32 : 1994(Power Input and Current ) |
- |
1000 |
|
N/A |
| Cl. 9 302-2-32 : 1994(Protection Against Electric Shock) |
- |
1000 |
|
N/A |
| Cl. 8 302-2-32 : 1994(Starting of motor operated appliances) |
- |
0 |
|
N/A |
| Cl. 7 302-2-32 : 1994(Marking) |
- |
500 |
|
N/A |
| (CI. 6 IS 302-2-32 : 1994(Classification ) |
- |
500 |
|
N/A |
| 19.11.4.1(Electrostatic discharges) |
- |
2000 |
|
N/A |
| 19.11.4.2(Radiated fields) |
- |
0 |
|
N/A |
| 19.11.4.3(Fast transient bursts) |
- |
0 |
|
N/A |
| 19.11.4.4(Surge immunity test) |
- |
1000 |
|
N/A |
| 19.11.4.5(Immunity to conducted discharges) |
- |
0 |
|
N/A |
| 19.11.4.6(Class 3 Voltage dips and interruptions) |
- |
0 |
|
N/A |
| 19.11.4.7(Harmonics) |
- |
0 |
|
N/A |
| Cl. 32 302-2-32 : 1994(Radiation Hazards) |
- |
- |
|
- |
| Cl. 31 302-2-32 : 1994(Resistance to Rusting) |
- |
- |
|
- |
| Cl. 30 302-2-32 : 1994(Resistance to Heat Fire & Tracking ) |
- |
- |
|
- |
| Cl. 29 302-2-32 : 1994(Clearances, Creepage Distances & Solid insulation ) |
- |
- |
|
- |
| Cl. 28 302-2-32 : 1994(Screws & Connections) |
- |
- |
|
- |
| Cl. 27 302-2-32 : 1994(Provision for Earthing ) |
- |
- |
|
- |
| Cl. 26 302-2-32 : 1994(Terminals for External conductors ) |
- |
- |
|
- |
| Cl. 25 302-2-32 : 1994(Supply Connection & External Flexible Cords) |
- |
- |
|
- |
| Cl. 24 302-2-32 : 1994(Components) |
- |
- |
|
- |
| Cl. 23 302-2-32 : 1994(Internal Wiring) |
- |
- |
|
- |
| Cl. 22 302-2-32 : 1994(Construction ) |
- |
- |
|
- |
| Cl. 21 302-2-32 : 1994(Mechanical strength) |
- |
- |
|
- |
| Cl. 20 302-2-32 : 1994(Stability & Mechanical Hazards) |
- |
- |
|
- |
| Cl. 19 302-2-32 : 1994(Abnormal Operation ) |
- |
- |
|
- |
| Cl. 18 302-2-32 : 1994(Endurance) |
- |
- |
|
- |
| Cl. 17 302-2-32 : 1994(Overload Protection of Transformers and Associated Circuit) |
- |
- |
|
- |
| Cl. 16 302-2-32 : 1994(Leakage Current & Electric Strength at Operating Temperature (After Humidity Treatment)) |
- |
- |
|
- |
| Cl. 15 302-2-32: 1994(Moisture Resistance Test ) |
- |
- |
|
- |
| Cl. 14 302-2-32 : 1994(Radio and television interference suppression / Transient over voltages) |
- |
- |
|
- |
| Cl. 13 302-2-32 : 1994(Leakage Current & Electric Strength at Operating Temperature) |
- |
- |
|
- |
| Cl. 11 302-2-32 : 1994(Temperature Rise) |
- |
- |
|
- |
| Cl. 10 302-2-32 : 1994(Power Input and Current ) |
- |
- |
|
- |
| Cl. 9 302-2-32 : 1994(Protection Against Electric Shock) |
- |
- |
|
- |
| Cl. 8 302-2-32 : 1994(Starting of motor operated appliances) |
- |
- |
|
- |
| Cl. 7 302-2-32 : 1994(Marking) |
- |
- |
|
- |
| (CI. 6 IS 302-2-32 : 1994(Classification ) |
- |
- |
|
- |
| 19.11.4.1(Electrostatic discharges) |
- |
- |
|
- |
| 19.11.4.2(Radiated fields) |
- |
- |
|
- |
| 19.11.4.3(Fast transient bursts) |
- |
- |
|
- |
| 19.11.4.4(Surge immunity test) |
- |
- |
|
- |
| 19.11.4.5(Immunity to conducted discharges) |
- |
- |
|
- |
| 19.11.4.6(Class 3 Voltage dips and interruptions) |
- |
- |
|
- |
| 19.11.4.7(Harmonics) |
- |
- |
|
- |
|
02 Sep, 2028 |
- Included w.e.f 14.10.2025
Exclusion: Cl 19.11.4.2 (Radiated fields), 19.11.4.3 (Fast transient bursts), 19.11.4.5 (Immunity to conducted discharges), 19.11.4.6 (Class 3 Voltage dips and interruptions), 19.11.4.7 (Harmonics), Cl. 32 302-2-32 : 1994 (Radiation Hazards) |
| 26 |
IS 302 : Part 2 : Sec 4 (1993) |
Safety of household and similar electrical appliances: Part 2 particular requirements: Sec 4 spin extractors |
-- |
38000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 3(GENERAL REQUIREMENTS) |
- |
0 |
|
N/A |
| 4(GENERAL NOTES ON TESTS) |
- |
0 |
|
N/A |
| 5(RATING) |
- |
500 |
|
N/A |
| 6(CLASSIFICATION) |
- |
500 |
|
N/A |
| 7(MARKING) |
- |
1000 |
|
N/A |
| 8(PROTECTION AGAINST ELECTRIC SHOCK) |
- |
1000 |
|
N/A |
| 9(STARTING OF MOTOR-OPERATED APPLIANCES) |
- |
0 |
|
N/A |
| 10(INPUT AND CURRENT) |
- |
1000 |
|
N/A |
| 11(HEATING) |
- |
2000 |
|
N/A |
| 13(ELECTRICAL INSULATION AND LEAKAGE CURRENT AT OPERATING TEMPERATURE) |
- |
2000 |
|
N/A |
| 14(RADIO AND TELEVISION INTERFERENCE SUPPRESSION) |
- |
2000 |
|
N/A |
| 15(MOISTURE RESISTANCE) |
- |
2000 |
|
N/A |
| 16(INSULATION RESISTANCE AND ELECTRIC STRENGTH (AFTER HUMIDITY TREATMENT)) |
- |
2000 |
|
N/A |
| 17(OVERLOAD PROTECTION) |
- |
2000 |
|
N/A |
| 19(ABNORMAL OPERATION) |
- |
1000 |
|
N/A |
| 20(STABILITY AND MECHANICAL HAZARDS) |
- |
2000 |
|
N/A |
| 21(MECHANICAL STRENGTH) |
- |
1000 |
|
N/A |
| 22(CONSTRUCTION) |
- |
2000 |
|
N/A |
| 23(INTERNAL WIRING) |
- |
1000 |
|
N/A |
| 24(COMPONENTS) |
- |
1000 |
|
N/A |
| 25(SUPPLY CONNECTION AND EXTERNAL FLEXIBLE CABLES AND CORDS) |
- |
2000 |
|
N/A |
| 26(TERMINALS FOR EXTERNAL CONDUCTORS) |
- |
1000 |
|
N/A |
| 27(PROVISION FOR EARTHING) |
- |
2000 |
|
N/A |
| 28(SCREWS AND CONNECTIONS) |
- |
1000 |
|
N/A |
| 29(CREEPAGE DISTANCES, CLEARANCES AND DISTANCES THROUGH INSULATION) |
- |
1000 |
|
N/A |
| 30(RESISTANCE TO HEAT, FIRE AND TRACKING) |
- |
2000 |
|
N/A |
| 31(RESISTANCE TO RUSTING) |
- |
1000 |
|
N/A |
| 19.11.4.1(Electrostatic discharges) |
- |
2000 |
|
N/A |
| 19.11.4.2(Radiated fields) |
- |
0 |
|
N/A |
| 19.11.4.3(Fast transient bursts) |
- |
0 |
|
N/A |
| 19.11.4.4(Surge immunity test) |
- |
2000 |
|
N/A |
| 19.11.4.5(Immunity to conducted discharges) |
- |
0 |
|
N/A |
| 19.11.4.6(Class 3 Voltage dips and interruptions) |
- |
0 |
|
N/A |
| 19.11.4.7(Harmonics) |
- |
0 |
|
N/A |
|
02 Sep, 2028 |
- Included w.e.f 29.10.2025
Exclusion: 19.11.4.2 (Radiated fields), 19.11.4.3 (Fast transient bursts) , 19.11.4.5 (Immunity to conducted discharges) , 19.11.4.6 (Class 3 Voltage dips and interruptions) , 19.11.4.7 (Harmonics) |
| 27 |
IS 302 : Part 2 : Sec 206 (1994) |
Safety of household and similar electrical appliances: Part 2 particular requirements: Sec 206 electric coffee makers |
-- |
25000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 32(Radiation hazards) |
- |
0 |
|
N/A |
| 31(Resistance to Rusting) |
- |
1000 |
|
N/A |
| 30(Resistance to Heat, Fire and Tracking) |
- |
1000 |
|
N/A |
| 29(Clearances, Creepage Distances & Solid Insulation) |
- |
1000 |
|
N/A |
| 28(Screws & Connection) |
- |
1000 |
|
N/A |
| 27(Provision For Earthing) |
- |
1000 |
|
N/A |
| 26(Terminals For External Conductors) |
- |
1000 |
|
N/A |
| 25(Supply Connection & External Flexible Cables and Cords) |
- |
1000 |
|
N/A |
| 24(Component) |
- |
1000 |
|
N/A |
| 23(Internal wiring) |
- |
1000 |
|
N/A |
| 22(Construction) |
- |
1000 |
|
N/A |
| 21(Mechanical strength) |
- |
1000 |
|
N/A |
| 20(Stability & Mechanical Hazards) |
- |
1000 |
|
N/A |
| 19(Abnormal Operation) |
- |
1000 |
|
N/A |
| 18(Endurance) |
- |
0 |
|
N/A |
| 17(Overload Protection) |
- |
1000 |
|
N/A |
| 16(Insulation resistance and Electric Strength (After humidity treatment)) |
- |
1000 |
|
N/A |
| 15(Moisture Resistance) |
- |
1000 |
|
N/A |
| 14(Radio and television interference suppression/ Transient Overvoltages) |
- |
1000 |
|
N/A |
| 13(Electrical insulation and Leakage Current at Operating Temperature) |
- |
1000 |
|
N/A |
| 12(Operation under overload conditions of appliances with heating elements) |
- |
1000 |
|
N/A |
| 11(Temperature Rise/Heating) |
- |
1000 |
|
N/A |
| 10(Input) |
- |
1000 |
|
N/A |
| 9(Starting Of Motor Operated Appliances) |
- |
0 |
|
N/A |
| 8(Protection against Electric Shock/ Protection against Access to Live Parts) |
- |
500 |
|
N/A |
| 7(Marking/ Marking & Instructions) |
- |
500 |
|
N/A |
| 6(Classification) |
- |
500 |
|
N/A |
| 5(Rating) |
- |
500 |
|
N/A |
| 19.11.4.1(Electrostatic discharges) |
- |
1000 |
|
N/A |
| 19.11.4.2(Radiated fields) |
- |
0 |
|
N/A |
| 19.11.4.3(Fast transient bursts) |
- |
0 |
|
N/A |
| 19.11.4.4(Surge immunity test) |
- |
1000 |
|
N/A |
| 19.11.4.5(Immunity to conducted discharges) |
- |
0 |
|
N/A |
| 19.11.4.6(Class 3 Voltage dips and interruptions) |
- |
0 |
|
N/A |
| 19.11.4.6(Class 3 Voltage dips and interruptions) |
- |
0 |
|
N/A |
| 19.11.4.7(Harmonics) |
- |
0 |
|
N/A |
|
02 Sep, 2028 |
- Included w.e.f 14.10.2025
Exclusion: Cl 19.11.4.2 (Radiated fields), 19.11.4.3 (Fast transient bursts), 19.11.4.5 (Immunity to conducted discharges), 19.11.4.6 (Class 3 Voltage dips and interruptions), 19.11.4.7 (Harmonics), 32 (Radiation hazards) |
| 28 |
IS 302 : Part 2 : Sec 209 (1994) |
Safety of household and similar electrical appliances: Part 2 particular requirements: Sec 209 low speed food grinding machines |
-- |
35000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl. 32 302-2-209 : 1994(Radiation Hazards) |
- |
0 |
|
N/A |
| Cl. 31 302-2-209 : 1994(Resistance to Rusting) |
- |
1000 |
|
N/A |
| Cl. 30 302-2-209 : 1994(Resistance to Heat Fire & Tracking ) |
- |
1000 |
|
N/A |
| Cl. 29 302-2-209 : 1994(Clearances, Creepage Distances & Solid insulation ) |
- |
1000 |
|
N/A |
| Cl. 28 302-2-209 : 1994(Screws & Connections) |
- |
2000 |
|
N/A |
| Cl. 27 302-2-209 : 1994(Provision for Earthing ) |
- |
2000 |
|
N/A |
| Cl. 26 302-2-209 : 1994(Terminals for External conductors ) |
- |
1000 |
|
N/A |
| Cl. 25 302-2-209 : 1994(Supply Connection & External Flexible Cords) |
- |
1000 |
|
N/A |
| Cl. 24 302-2-209 : 1994(Components) |
- |
1000 |
|
N/A |
| Cl. 23 302-2-209 : 1994(Internal Wiring) |
- |
1000 |
|
N/A |
| Cl. 22 302-2-209 : 1994(Construction ) |
- |
1000 |
|
N/A |
| Cl. 21 302-2-209 : 1994(Mechanical strength) |
- |
1000 |
|
N/A |
| Cl. 20 302-2-209 : 1994(Stability & Mechanical Hazards) |
- |
1000 |
|
N/A |
| Cl. 19 302-2-209 : 1994(Abnormal Operation ) |
- |
2000 |
|
N/A |
| Cl. 18 302-2-209 : 1994(Endurance) |
- |
0 |
|
N/A |
| Cl. 17 302-2-209 : 1994(Overload Protection of Transformers and Associated Circuit) |
- |
2000 |
|
N/A |
| Cl. 16 302-2-209 : 1994(Leakage Current & Electric Strength at Operating Temperature (After Humidity Treatment)) |
- |
2000 |
|
N/A |
| Cl. 15 302-2-209 : 1994(Moisture Resistance Test ) |
- |
2000 |
|
N/A |
| Cl. 14 302-2-209 : 1994(Radio and television interference suppression / Transient over voltages) |
- |
1000 |
|
N/A |
| Cl. 13 302-2-209 : 1994(Leakage Current & Electric Strength at Operating Temperature) |
- |
1000 |
|
N/A |
| Cl. 11 302-2-209 : 1994(Temperature Rise) |
- |
1000 |
|
N/A |
| Cl. 10 302-2-209 : 1994(Power Input and Current ) |
- |
1000 |
|
N/A |
| Cl. 9 302-2-209 : 1994(Starting of motor operated appliances) |
- |
1000 |
|
N/A |
| Cl. 8 302-2-209 : 1994(Protection Against Electric Shock ) |
- |
1000 |
|
N/A |
| Cl. 7 302-2-209 : 1994(Marking) |
- |
1000 |
|
N/A |
| (CI. 6 IS 302-2-209 : 1994(Classification ) |
- |
1000 |
|
N/A |
| Cl. 5 IS 302-2-209 :1994(Rating) |
- |
1000 |
|
N/A |
| Cl-19.11.4.1(Electrostatic discharge) |
- |
2000 |
|
N/A |
| Cl-19.11.4.2(Radiated Fields) |
- |
0 |
|
N/A |
| Cl-19.11.4.3(Fast transient bursts) |
- |
0 |
|
N/A |
| Cl-19.11.4.4(Surge Immunity test) |
- |
2000 |
|
N/A |
| Cl-19.11.4.5(Immunity to conducted discharge) |
- |
0 |
|
N/A |
| Cl-19.11.4.6(Voltage dips and interruptions) |
- |
0 |
|
N/A |
| Cl-19.11.4.7(Harmonics) |
- |
0 |
|
N/A |
| Cl. 32 302-2-209 : 1994(Radiation Hazards) |
- |
- |
|
- |
| Cl. 31 302-2-209 : 1994(Resistance to Rusting) |
- |
- |
|
- |
| Cl. 30 302-2-209 : 1994(Resistance to Heat Fire & Tracking ) |
- |
- |
|
- |
| Cl. 29 302-2-209 : 1994(Clearances, Creepage Distances & Solid insulation ) |
- |
- |
|
- |
| Cl. 28 302-2-209 : 1994(Screws & Connections) |
- |
- |
|
- |
| Cl. 27 302-2-209 : 1994(Provision for Earthing ) |
- |
- |
|
- |
| Cl. 26 302-2-209 : 1994(Terminals for External conductors ) |
- |
- |
|
- |
| Cl. 25 302-2-209 : 1994(Supply Connection & External Flexible Cords) |
- |
- |
|
- |
| Cl. 24 302-2-209 : 1994(Components) |
- |
- |
|
- |
| Cl. 23 302-2-209 : 1994(Internal Wiring) |
- |
- |
|
- |
| Cl. 22 302-2-209 : 1994(Construction ) |
- |
- |
|
- |
| Cl. 21 302-2-209 : 1994(Mechanical strength) |
- |
- |
|
- |
| Cl. 20 302-2-209 : 1994(Stability & Mechanical Hazards) |
- |
- |
|
- |
| Cl. 19 302-2-209 : 1994(Abnormal Operation ) |
- |
- |
|
- |
| Cl. 18 302-2-209 : 1994(Endurance) |
- |
- |
|
- |
| Cl. 17 302-2-209 : 1994(Overload Protection of Transformers and Associated Circuit) |
- |
- |
|
- |
| Cl. 16 302-2-209 : 1994(Leakage Current & Electric Strength at Operating Temperature (After Humidity Treatment)) |
- |
- |
|
- |
| Cl. 15 302-2-209 : 1994(Moisture Resistance Test ) |
- |
- |
|
- |
| Cl. 14 302-2-209 : 1994(Radio and television interference suppression / Transient over voltages) |
- |
- |
|
- |
| Cl. 13 302-2-209 : 1994(Leakage Current & Electric Strength at Operating Temperature) |
- |
- |
|
- |
| Cl. 11 302-2-209 : 1994(Temperature Rise) |
- |
- |
|
- |
| Cl. 10 302-2-209 : 1994(Power Input and Current ) |
- |
- |
|
- |
| Cl. 9 302-2-209 : 1994(Starting of motor operated appliances) |
- |
- |
|
- |
| Cl. 8 302-2-209 : 1994(Protection Against Electric Shock ) |
- |
- |
|
- |
| Cl. 7 302-2-209 : 1994(Marking) |
- |
- |
|
- |
| (CI. 6 IS 302-2-209 : 1994(Classification ) |
- |
- |
|
- |
| Cl. 5 IS 302-2-209 :1994(Rating) |
- |
- |
|
- |
| Cl-19.11.4.1(Electrostatic discharge) |
- |
- |
|
- |
| Cl-19.11.4.2(Radiated Fields) |
- |
- |
|
- |
| Cl-19.11.4.3(Fast transient bursts) |
- |
- |
|
- |
| Cl-19.11.4.4(Surge Immunity test) |
- |
- |
|
- |
| Cl-19.11.4.5(Immunity to conducted discharge) |
- |
- |
|
- |
| Cl-19.11.4.6(Voltage dips and interruptions) |
- |
- |
|
- |
| Cl-19.11.4.7(Harmonics) |
- |
- |
|
- |
|
02 Sep, 2028 |
- Included w.e.f 14.10.2025
Exclusion: Cl 19.11.4.2 (Radiated fields), 19.11.4.3 (Fast transient bursts), 19.11.4.5 (Immunity to conducted discharges), 19.11.4.6 (Class 3 Voltage dips and interruptions), 19.11.4.7 (Harmonics), Cl. 32 302-2-209 : 1994 (Radiation Hazards) |
| 29 |
IS 302 : Part 2 : Sec 8 (2024) |
Household and Similar Electrical Appliances âSafety Part 2 Particular Requirements Section 8 Shavers, Hair Clippers and Similar Appliances (First Revision) |
-- |
35000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 7(Marking and instructions) |
- |
1000 |
|
N/A |
| 8(Protection against access to live parts) |
- |
1000 |
|
N/A |
| 10(Power input and current) |
- |
1000 |
|
N/A |
| 11(Heating) |
- |
2000 |
|
N/A |
| 12(Charging of metal-ion batteries) |
- |
1000 |
|
N/A |
| 13.1 &13.2(Leakage current test) |
- |
1000 |
|
N/A |
| 13.1 &13.3(Electric strength test) |
- |
2000 |
|
N/A |
| 14(Transient overvoltages) |
- |
2000 |
|
N/A |
| 15(Moisture resistance) |
- |
2000 |
|
N/A |
| 15.3(Moisture resistance) |
- |
1000 |
|
N/A |
| 16.1 &16.2(Leakage current test) |
- |
1000 |
|
N/A |
| 16.1 & 16.3(Electric strength test) |
- |
1000 |
|
N/A |
| 17(Overload protection of transformers and associated circuits) |
- |
1000 |
|
N/A |
| 19.1 to 19.13, Table No. - 9(Abnormal operation) |
- |
1000 |
|
N/A |
| 19.101(Abnormal operation) |
- |
1000 |
|
N/A |
| 20.1(Stability and mechanical hazards) |
- |
1000 |
|
N/A |
| 20.2(Stability and mechanical hazards) |
- |
0 |
|
N/A |
| 21(Mechanical strength) |
- |
1000 |
|
N/A |
| 21.101(Mechanical strength) |
- |
0 |
|
N/A |
| 21.102(Mechanical strength) |
- |
0 |
|
N/A |
| 21.103(Mechanical strength) |
- |
0 |
|
N/A |
| 22(Construction) |
- |
1000 |
|
N/A |
| 22.101(Construction) |
- |
0 |
|
N/A |
| 22.102(Construction) |
- |
1000 |
|
N/A |
| 22.103(Construction) |
- |
1000 |
|
N/A |
| 23(Internal wiring) |
- |
2000 |
|
N/A |
| 24(Components) |
- |
0 |
|
N/A |
| 25("Supply connection and
external flexible cords") |
- |
1000 |
|
N/A |
| 26("Terminals for external
conductors") |
- |
1000 |
|
N/A |
| 27(Provision for earthing) |
- |
1000 |
|
N/A |
| 28(Screws and connections) |
- |
1000 |
|
N/A |
| 29("Clearances, creepage
distances and solid insulation") |
- |
1000 |
|
N/A |
| 30(Resistance to heat and fire) |
- |
2000 |
|
N/A |
| 31(Resistance to rusting) |
- |
2000 |
|
N/A |
| 32("Radiation, toxicity and similar
hazards") |
- |
0 |
|
N/A |
| 19.11.4.1(Electrostatic discharges) |
- |
0 |
|
N/A |
| 19.11.4.2(Radiated fields) |
- |
0 |
|
N/A |
| 19.11.4.3(Fast transient bursts) |
- |
0 |
|
N/A |
| 19.11.4.4(Surge immunity test) |
- |
0 |
|
N/A |
| 19.11.4.5(Immunity to conducted discharges) |
- |
0 |
|
N/A |
| 19.11.4.6(Class 3 Voltage dips and interruptions) |
- |
0 |
|
N/A |
| 19.11.4.7(Harmonics) |
- |
0 |
|
N/A |
|
02 Sep, 2028 |
- Exclusion: 19.11.4.1 to 19.11.4.7 (EMI/EMC), 32 (Radiation, Toxicity and similar Hazard ), 24 (COMPONENTS) |
| 30 |
IS 302 : Part 2 : Sec 59 (2024) |
Household and Similar Electrical Appliances â Safety Part 2 Particular Requirements Section 59 Insect Killers (First Revision) |
-- |
35000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4(General) |
- |
500 |
|
N/A |
| 5(General conditions for the tests) |
- |
500 |
|
N/A |
| 6(Classification) |
- |
1000 |
|
N/A |
| 7(Marking and instructions) |
- |
1000 |
|
N/A |
| 8("8 PROTECTION AGAINST ELECTRIC
SHOCK ") |
- |
2000 |
|
N/A |
| 10(Power input and current) |
- |
2000 |
|
N/A |
| 11(Heating) |
- |
1000 |
|
N/A |
| 11.3(Heating) |
- |
1000 |
|
N/A |
| 11.7(Heating) |
- |
500 |
|
N/A |
| 11.8(Heating) |
- |
500 |
|
N/A |
| 12(Charging of metal-ion batteries) |
- |
1000 |
|
N/A |
| 13(Leakage current and electric strength at operating temperature) |
- |
2000 |
|
N/A |
| 14(Transient overvoltages) |
- |
2000 |
|
N/A |
| 15(MOISTURE RESISTANCE) |
- |
2000 |
|
N/A |
| 16(Leakage current and electric strength) |
- |
1000 |
|
N/A |
| 17(Overload protection of transformers and associated circuits) |
- |
1000 |
|
N/A |
| 19(ABNORMAL OPERATION) |
- |
2000 |
|
N/A |
| 19.11.4.1(Electrostatic discharges) |
- |
0 |
|
N/A |
| 19.11.4.2(Radiated fields) |
- |
0 |
|
N/A |
| 19.11.4.3(Fast transient bursts) |
- |
0 |
|
N/A |
| 19.11.4.4(Voltage surges) |
- |
0 |
|
N/A |
| 19.11.4.5(Injected currents) |
- |
0 |
|
N/A |
| 19.11.4.6(Class 3 Voltage dips and interruptions) |
- |
0 |
|
N/A |
| 19.11.4.7(Mains signals) |
- |
0 |
|
N/A |
| 20("STABILITY AND MECHANICAL
HAZARDS") |
- |
1000 |
|
N/A |
| 21(MECHANICAL STRENGTH) |
- |
1000 |
|
N/A |
| 22(CONSTRUCTION) |
- |
1000 |
|
N/A |
| 23(INTERNAL WIRING) |
- |
2000 |
|
N/A |
| 24(COMPONENTS) |
- |
0 |
|
N/A |
| 25("SUPPLY CONNECTION AND EXTERNAL
FLEXIBLE CABLES AND CORDS ") |
- |
1000 |
|
N/A |
| 26("TERMINALS FOR EXTERNAL
CONDUCTORS") |
- |
1000 |
|
N/A |
| 27(PROVISION FOR EARTHING) |
- |
1000 |
|
N/A |
| 28(SCREWS AND CONNECTIONS) |
- |
1000 |
|
N/A |
| 30("RESISTANCE TO HEAT, FIRE AND
TRACKING ") |
- |
2000 |
|
N/A |
| 31(RESISTANCE TO RUSTING) |
- |
1000 |
|
N/A |
| 32(Radiation, toxicity and similar hazards) |
- |
0 |
|
N/A |
| 29(Clearances, creepage distances and solid insulation) |
- |
2000 |
|
N/A |
|
02 Sep, 2028 |
- Exclusion: 19.11.4.1 to 19.11.4.7 (EMI/EMC), 32 (Radiation, Toxicity and similar Hazard ), 24 (COMPONENTS) |