| 1 |
IS 8783 : Part 4 : Sec 3 (1995) |
Winding wires for submersible motors - Specification: Part 4 specification for individual wires: Sec 3 polyester and polypropylene insulated winding wires (First Revision) |
- |
13800 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 5.1(The winding wire shall either be wound on spools / reels conforming to IS 482-1981. or supplied in a coils packed and labelled.) |
- |
0 |
|
- |
| 6.1(The winding wire shall carry following information marked on the lable on spool / reel / coil;) |
- |
0 |
|
- |
| 6.1(a) Reference to this Indian Standard;) |
- |
0 |
|
- |
| 6.1(b) Manufacturer's name,brand name or trade-mark;) |
- |
0 |
|
- |
| 6.1(c) Size of conductor / maximum overall diameter,) |
- |
0 |
|
- |
| 6.1(d) Length of conductor on spool / reel /coil;) |
- |
0 |
|
- |
| 6.1(e) Number of lengths onspool / reel / coil (if more than one);) |
- |
0 |
|
- |
| 6.1(f) Country of Manufacturer) |
- |
0 |
|
- |
| 6.1(g) Year of Manufacture.) |
- |
0 |
|
- |
| 6.2(BIS Certification Mark) |
- |
0 |
|
- |
| 4(i) Material) |
- |
0 |
|
- |
| 5(ii) Diameter [mm] Seperate wire:) |
- |
0 |
|
- |
| 5(ii) Diameter [mm] Wire taken from cable:) |
- |
0 |
|
- |
| 5(iii) Annealing test [Percentage] on Seperate wire:) |
- |
0 |
|
- |
| 5(iii) Annealing test [Percentage] on Wire taken from cable:) |
- |
0 |
|
- |
| 5(d) Resistance test [Ohm/km corrected to 20°c) |
- |
0 |
|
- |
| 4.1, table 1 & 2(a) Thickness of Polyster (mm)) |
- |
0 |
|
- |
| 4.1, table 1 & 3(b) Thickness of Polypropylene (mm)) |
- |
0 |
|
- |
| 4.1, table 1 & 4(c) Total thickness of Insulation(mm)) |
- |
0 |
|
- |
| 4.2(Application of insulation) |
- |
0 |
|
- |
| 4.3(Colour of Insuation) |
- |
0 |
|
- |
| 4.4(Overall diameter (mm)) |
- |
0 |
|
- |
| 4(Before ageing Tensile strength [N/mm²]) |
- |
0 |
|
- |
| 4(Before ageing Elongation at break [Percentage]) |
- |
0 |
|
- |
| 4(After ageing Tensile strength [N/mm²]) |
- |
0 |
|
- |
| 4(Variation on tensile strangth [Percentage]) |
- |
0 |
|
- |
| 4(After ageing Elongation at break [Percentage]) |
- |
0 |
|
- |
| 4(Variation on elongation at break [Percentage]) |
- |
0 |
|
- |
| 4(Shrinkage test [Percentage]) |
- |
0 |
|
- |
| 4(After Shrinkage Cracks found.) |
- |
0 |
|
- |
| 4.1(Water absorption test [Gravimetric] [mg/cm²]) |
- |
0 |
|
- |
| 4.1(Hot Deformation test [depth of indentation) [Percentage]) |
- |
0 |
|
- |
| 4.1(Heat Shock Test - No cracks found) |
- |
0 |
|
- |
| 4.5(High Voltage test [Water Immersion test] 3 KV for 1 Minute) |
- |
0 |
|
- |
| 4.1(Insulation Resistance test [ohm-cm] At 27 ºC) |
- |
0 |
|
- |
| 4.1([Insulation Resistance test [ohm-cm] At 90 ºC) |
- |
0 |
|
- |
| 5(The winding wire shall either be wound on spools / reels conforming to IS 482-1981. or supplied in a coils packed and labelled.) |
- |
0 |
|
- |
| 6(The winding wire shall carry following information marked on the lable on spool / reel / coil;) |
- |
0 |
|
- |
| 6(a) Reference to this Indian Standard;) |
- |
0 |
|
- |
| 6(b) Manufacturer's name,brand name or trade-mark;) |
- |
0 |
|
- |
| 6(c) Size of conductor / maximum overall diameter,) |
- |
0 |
|
- |
| 6(d) Length of conductor on spool / reel /coil;) |
- |
0 |
|
- |
| 6(e) Number of lengths onspool / reel / coil (if more than one);) |
- |
0 |
|
- |
| 6(f) Country of Manufacturer Marking) |
- |
0 |
|
- |
| 6(g) Year of Manufacture.) |
- |
0 |
|
- |
| 6.2(BIS Certification Mark) |
- |
0 |
|
- |
| 4(i) Material) |
- |
0 |
|
- |
| 4(ii) Diameter [mm] Seperate wire:) |
- |
0 |
|
- |
| 4(ii) Diameter [mm] Wire taken from cable) |
- |
0 |
|
- |
| 4(iii) Annealing test [Percentage] on Seperate wire:) |
- |
0 |
|
- |
| 4([iii) Annealing test [Percentage] on Wire taken from cable:) |
- |
0 |
|
- |
| 4(d) Resistance test [Ohm/km corrected to 20°c]) |
- |
0 |
|
- |
| 4(a) Thickness of Polyster (mm)) |
- |
0 |
|
- |
| 4(b) Thickness of Polypropylene (mm)) |
- |
0 |
|
- |
| 4(c) Total thickness of Insulation(mm)) |
- |
0 |
|
- |
| 4(Application of insulation) |
- |
0 |
|
- |
| 4(Colour of Insuation) |
- |
0 |
|
- |
| 4(Overall diameter (mm)) |
- |
0 |
|
- |
| 4(Before ageing Tensile strength [N/mm²]) |
- |
0 |
|
- |
| 4(Before ageing Elongation at break [Percentage]) |
- |
0 |
|
- |
| 4(After ageing Tensile strength [N/mm²]) |
- |
0 |
|
- |
| 4(Variation on tensile strangth [Percentage]) |
- |
0 |
|
- |
| 4(After ageing Elongation at break [Percentage]) |
- |
0 |
|
- |
| 4(Variation on elongation at break [Percentage]) |
- |
0 |
|
- |
| 4(Shrinkage test [Percentage]) |
- |
0 |
|
- |
| 4(After Shrinkage Cracks found.) |
- |
0 |
|
- |
| 4(Water absorption test [Gravimetric] [mg/cm²]) |
- |
0 |
|
- |
| 4(Hot Deformation test [depth of indentation) [Percentage]) |
- |
0 |
|
- |
| 4(Heat Shock Test - No cracks found Physical) |
- |
0 |
|
- |
| 4(High Voltage test [Water Immersion test] 3 KV for 1 Minute) |
- |
0 |
|
- |
| 4(Insulation Resistance test [ohm-cm] At 27 ºC) |
- |
0 |
|
- |
| 4(Insulation Resistance test [ohm-cm] At 90 ºC) |
- |
0 |
|
- |
| Clause No. 3(Insulation Resistance (Volume Resistivity at test temperature 90 º C )) |
- |
0 |
|
- |
| Clause No. 3(Water absorption) |
- |
0 |
|
- |
| Clause No. 3(Hot Deformation) |
- |
0 |
|
- |
| Clause No. 3(Shrinkage) |
- |
0 |
|
- |
| Clause No. 3(Heat Shock) |
- |
0 |
|
- |
| Clause No. 3(Thickness of Insulation) |
- |
0 |
|
- |
| Clause No. 3(Annealing Test) |
- |
0 |
|
- |
| Clause No. 3(Conductor Diameter) |
- |
0 |
|
- |
| Clause No. 3(Overall Dimensions) |
- |
0 |
|
- |
| Clause No. 3(Insulation Resistance (Volume Resistivity at 27º C )) |
- |
0 |
|
- |
| Clause No. 3(High Voltage Test (Water Immersion test) at room temperature) |
- |
0 |
|
- |
| Clause No. 3(Conductor Resistance) |
- |
0 |
|
- |
| Table 1, Cl. 4.1, VI(Water Absorbtion Test (Gravimetric)) |
- |
0 |
|
- |
| Cl. 4.1 of IS: 8783 (Pt-2)(Insulation Resistance Test) |
- |
0 |
|
- |
| Cl. 4.1 of IS: 8783 (Pt-2)(Insulation Resistance Test) |
- |
0 |
|
- |
| Cl.4.1 of IS: 8783 (Pt-2):1995(Physical Test for Insulation after Ageing (on finished wire)) |
- |
0 |
|
- |
|
28 Oct, 2028 |
- Included w.e.f 18.09.2026 |
| 2 |
IS 6595 : Part 1 (2018) |
Horizontal centrifugal pumps for clear, cold water - Specification: Part 1 agricultural and rural water supply purposes (Fourth Revision) |
- |
7250 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 10.1(Pump Test
Verification of the Guarantee
Cl.9.4 of IS 9137:2019
Cl. 9.4.1 Curves QH and Qη) |
- |
0 |
|
Rs. 6350/- Up to 105mm delivery, Rs.7250/- Above 105 mm and Upto 155mm delivery |
| 10.1(Pump Test
Verification of the Guarantee
Cl.9.4 of IS 9137:2019
9.4.2 Efficiency) |
- |
0 |
|
Rs. 6350/- Up to 105mm delivery, Rs.7250/- Above 105 mm and Upto 155mm delivery |
| 10.1(Pump Test
Verification of the Guarantee
Cl.9.4 of IS 9137:2019
9.4.3 Pump Power Input) |
- |
0 |
|
Rs. 6350/- Up to 105mm delivery, Rs.7250/- Above 105 mm and Upto 155mm delivery |
| 8.1(Design Features
Head Restrictions) |
- |
0 |
|
Rs. 6350/- Up to 105mm delivery, Rs.7250/- Above 105 mm and Upto 155mm delivery |
| 8.1(Design Features
Head Restrictions) |
- |
0 |
|
Rs. 6350/- Up to 105mm delivery, Rs.7250/- Above 105 mm and Upto 155mm delivery |
| 8.2
As per fig 1 & 2(Design Features
Minimum efficiency
) |
- |
0 |
|
Rs. 6350/- Up to 105mm delivery, Rs.7250/- Above 105 mm and Upto 155mm delivery |
| 8.3(Design Features
Shaft ) |
- |
0 |
|
Rs. 6350/- Up to 105mm delivery, Rs.7250/- Above 105 mm and Upto 155mm delivery |
| 9.1(General Requirements
Volute Casing) |
- |
0 |
|
Rs. 6350/- Up to 105mm delivery, Rs.7250/- Above 105 mm and Upto 155mm delivery |
| 9.2(General Requirements
Impeller) |
- |
0 |
|
Rs. 6350/- Up to 105mm delivery, Rs.7250/- Above 105 mm and Upto 155mm delivery |
| 10(Pump Test
Verification of guarante
Cl.8 of IS 11346-2002
Rate of flow and head
Cl.8 of IS 11346-2002) |
- |
0 |
|
Rs. 6350/- Up to 105mm delivery, Rs.7250/- Above 105 mm and Upto 155mm delivery |
| 10(Pump Test
Verification of guarante
Cl.8 of IS 11346-2002
Rate of flow and head
Cl.8 of IS 11346-2002) |
- |
0 |
|
Rs. 6350/- Up to 105mm delivery, Rs.7250/- Above 105 mm and Upto 155mm delivery |
| 10(Pump Test
Verification of guarante
Cl.8 of IS 11346-2002
Efficiency
Cl.8.3 of IS 11346-2002) |
- |
0 |
|
Rs. 6350/- Up to 105mm delivery, Rs.7250/- Above 105 mm and Upto 155mm delivery |
| 12.2.2(Pump Power Input
) |
- |
0 |
|
Rs. 6350/- Up to 105mm delivery, Rs.7250/- Above 105 mm and Upto 155mm delivery |
| 12.2.5(Vibrations ) |
- |
0 |
|
Rs. 6350/- Up to 105mm delivery, Rs.7250/- Above 105 mm and Upto 155mm delivery |
| 12.2.5(Noise level) |
- |
0 |
|
Rs. 6350/- Up to 105mm delivery, Rs.7250/- Above 105 mm and Upto 155mm delivery |
| Cl. 8.3(Design Features) |
- |
0 |
|
Rs. 6350/- Up to 105mm delivery, Rs.7250/- Above 105 mm and Upto 155mm delivery |
| Cl. 8.2(Design Features) |
- |
0 |
|
Rs. 6350/- Up to 105mm delivery, Rs.7250/- Above 105 mm and Upto 155mm delivery |
| Cl. 8.1 (b)(Design Features) |
- |
0 |
|
Rs. 6350/- Up to 105mm delivery, Rs.7250/- Above 105 mm and Upto 155mm delivery |
| Cl. 8.1 (a)(Design Features) |
- |
0 |
|
Rs. 6350/- Up to 105mm delivery, Rs.7250/- Above 105 mm and Upto 155mm delivery |
| Cl. 12.2.6(Noise) |
- |
0 |
|
Rs. 6350/- Up to 105mm delivery, Rs.7250/- Above 105 mm and Upto 155mm delivery |
| Cl. 12.2.5(Vibrations) |
- |
0 |
|
Rs. 6350/- Up to 105mm delivery, Rs.7250/- Above 105 mm and Upto 155mm delivery |
| Cl. 12(Guarantee and tolerances on Pump performance (I/P Power)) |
- |
0 |
|
Rs. 6350/- Up to 105mm delivery, Rs.7250/- Above 105 mm and Upto 155mm delivery |
| Cl. 12(Guarantee and tolerances on Pump performance (Efficiency)) |
- |
0 |
|
Rs. 6350/- Up to 105mm delivery, Rs.7250/- Above 105 mm and Upto 155mm delivery |
| Cl. 12(Guarantee and tolerances on Pump performance (Discharge)) |
- |
0 |
|
Rs. 6350/- Up to 105mm delivery, Rs.7250/- Above 105 mm and Upto 155mm delivery |
| Cl. 12(Guarantee and tolerances on Pump performance (Head)) |
- |
0 |
|
Rs. 6350/- Up to 105mm delivery, Rs.7250/- Above 105 mm and Upto 155mm delivery |
| Cl. 9.2(Impeller) |
- |
0 |
|
Rs. 6350/- Up to 105mm delivery, Rs.7250/- Above 105 mm and Upto 155mm delivery |
| Cl. 9.1(Voult casing) |
- |
0 |
|
Rs. 6350/- Up to 105mm delivery, Rs.7250/- Above 105 mm and Upto 155mm delivery |
| Cl. 7.2(Directin of rotation) |
- |
0 |
|
Rs. 6350/- Up to 105mm delivery, Rs.7250/- Above 105 mm and Upto 155mm delivery |
| Cl. 6.2(Gasket, Seals and Packings) |
- |
0 |
|
Rs. 6350/- Up to 105mm delivery, Rs.7250/- Above 105 mm and Upto 155mm delivery |
| Cl. 6.1(Material of Construction) |
- |
1500 |
|
Rs. 6350/- Up to 105mm delivery, Rs.7250/- Above 105 mm and Upto 155mm delivery |
| Cl. 14 (h)(Arrow to indication direction of rotation) |
- |
0 |
|
Rs. 6350/- Up to 105mm delivery, Rs.7250/- Above 105 mm and Upto 155mm delivery |
| Cl. 14 (g)(Recommanded Prime mover in kW) |
- |
0 |
|
Rs. 6350/- Up to 105mm delivery, Rs.7250/- Above 105 mm and Upto 155mm delivery |
| Cl. 14 (f)(Discharge Range in L/s Corosponding to specified head range) |
- |
0 |
|
Rs. 6350/- Up to 105mm delivery, Rs.7250/- Above 105 mm and Upto 155mm delivery |
| Cl. 14 (e)(Head Range in m for non overloading Requirment) |
- |
0 |
|
Rs. 6350/- Up to 105mm delivery, Rs.7250/- Above 105 mm and Upto 155mm delivery |
| Cl. 14 (d)(Nominal Head in m, Nominal Discharge in L/s and Pump Efficiency in percent of nominal head) |
- |
0 |
|
Rs. 6350/- Up to 105mm delivery, Rs.7250/- Above 105 mm and Upto 155mm delivery |
| Cl. 14 (c)(Rated Speed) |
- |
0 |
|
Rs. 6350/- Up to 105mm delivery, Rs.7250/- Above 105 mm and Upto 155mm delivery |
| Cl. 14 (b)(Model, Size) |
- |
0 |
|
Rs. 6350/- Up to 105mm delivery, Rs.7250/- Above 105 mm and Upto 155mm delivery |
| Cl. 14 (a)(Manufacturer's name or Registerd trade-mark) |
- |
0 |
|
Rs. 6350/- Up to 105mm delivery, Rs.7250/- Above 105 mm and Upto 155mm delivery |
| 7.1(Direction of Rotation) |
- |
0 |
|
Rs. 6350/- Up to 105mm delivery, Rs.7250/- Above 105 mm and Upto 155mm delivery |
| 10(Pump Test) |
- |
0 |
|
Rs. 6350/- Up to 105mm delivery, Rs.7250/- Above 105 mm and Upto 155mm delivery |
| 8.4 (amendment-1)(Pump Efficiency) |
- |
0 |
|
Rs. 6350/- Up to 105mm delivery, Rs.7250/- Above 105 mm and Upto 155mm delivery |
| 8.2 (amendment-1)(minimum pump efficiency) |
- |
0 |
|
Rs. 6350/- Up to 105mm delivery, Rs.7250/- Above 105 mm and Upto 155mm delivery |
| 11.1(Guarantee of Workmanship & material) |
- |
0 |
|
Rs. 6350/- Up to 105mm delivery, Rs.7250/- Above 105 mm and Upto 155mm delivery |
| 15.2(Laboratory Tests
Cl.8 of IS 11346-2002
Rate of flow and head
Cl.8 of IS 11346-2002) |
- |
0 |
|
Rs. 6350/- Up to 105mm delivery, Rs.7250/- Above 105 mm and Upto 155mm delivery |
| 10.1(Pump Test
Verification of the Guarantee
Cl.9.4 of IS 9137:2019
Cl. 9.4.1 Curves QH and Qη) |
- |
0 |
|
- |
| 10.1(Pump Test
Verification of the Guarantee
Cl.9.4 of IS 9137:2019
9.4.2 Efficiency) |
- |
0 |
|
- |
| 10.1(Pump Test
Verification of the Guarantee
Cl.9.4 of IS 9137:2019
9.4.3 Pump Power Input) |
- |
0 |
|
- |
| 8.1(Design Features
Head Restrictions) |
- |
0 |
|
- |
| 8.1(Design Features
Head Restrictions) |
- |
0 |
|
- |
| 8.2
As per fig 1 & 2(Design Features
Minimum efficiency
) |
- |
0 |
|
- |
| 8.3(Design Features
Shaft ) |
- |
0 |
|
- |
| 9.1(General Requirements
Volute Casing) |
- |
0 |
|
- |
| 9.2(General Requirements
Impeller) |
- |
0 |
|
- |
| 10(Pump Test
Verification of guarante
Cl.8 of IS 11346-2002
Rate of flow and head
Cl.8 of IS 11346-2002) |
- |
0 |
|
- |
| 10(Pump Test
Verification of guarante
Cl.8 of IS 11346-2002
Rate of flow and head
Cl.8 of IS 11346-2002) |
- |
0 |
|
- |
| 10(Pump Test
Verification of guarante
Cl.8 of IS 11346-2002
Efficiency
Cl.8.3 of IS 11346-2002) |
- |
0 |
|
- |
| 12.2.2(Pump Power Input
) |
- |
0 |
|
- |
| 12.2.5(Vibrations ) |
- |
0 |
|
- |
| 12.2.5(Noise level) |
- |
0 |
|
- |
| Cl. 8.3(Design Features) |
- |
0 |
|
- |
| Cl. 8.2(Design Features) |
- |
0 |
|
- |
| Cl. 8.1 (b)(Design Features) |
- |
0 |
|
- |
| Cl. 8.1 (a)(Design Features) |
- |
0 |
|
- |
| Cl. 12.2.6(Noise) |
- |
0 |
|
- |
| Cl. 12.2.5(Vibrations) |
- |
0 |
|
- |
| Cl. 12(Guarantee and tolerances on Pump performance (I/P Power)) |
- |
0 |
|
- |
| Cl. 12(Guarantee and tolerances on Pump performance (Efficiency)) |
- |
0 |
|
- |
| Cl. 12(Guarantee and tolerances on Pump performance (Discharge)) |
- |
0 |
|
- |
| Cl. 12(Guarantee and tolerances on Pump performance (Head)) |
- |
0 |
|
- |
| Cl. 9.2(Impeller) |
- |
0 |
|
- |
| Cl. 9.1(Voult casing) |
- |
0 |
|
- |
| Cl. 7.2(Directin of rotation) |
- |
0 |
|
- |
| Cl. 6.2(Gasket, Seals and Packings) |
- |
0 |
|
- |
| Cl. 6.1(Material of Construction) |
- |
0 |
|
- |
| Cl. 14 (h)(Arrow to indication direction of rotation) |
- |
0 |
|
- |
| Cl. 14 (g)(Recommanded Prime mover in kW) |
- |
0 |
|
- |
| Cl. 14 (f)(Discharge Range in L/s Corosponding to specified head range) |
- |
0 |
|
- |
| Cl. 14 (e)(Head Range in m for non overloading Requirment) |
- |
0 |
|
- |
| Cl. 14 (d)(Nominal Head in m, Nominal Discharge in L/s and Pump Efficiency in percent of nominal head) |
- |
0 |
|
- |
| Cl. 14 (c)(Rated Speed) |
- |
0 |
|
- |
| Cl. 14 (b)(Model, Size) |
- |
0 |
|
- |
| Cl. 14 (a)(Manufacturer's name or Registerd trade-mark) |
- |
0 |
|
- |
| 7.1(Direction of Rotation) |
- |
0 |
|
- |
| 10(Pump Test) |
- |
0 |
|
- |
| 8.4 (amendment-1)(Pump Efficiency) |
- |
0 |
|
- |
| 8.2 (amendment-1)(minimum pump efficiency) |
- |
0 |
|
- |
| 11.1(Guarantee of Workmanship & material) |
- |
0 |
|
- |
| 15.2(Laboratory Tests
Cl.8 of IS 11346-2002
Rate of flow and head
Cl.8 of IS 11346-2002) |
- |
0 |
|
- |
|
28 Oct, 2028 |
- Included w.e.f 18.09.2026 |
| 3 |
IS 8418 (1999) |
Pumps - Centrifugal self priming - Specification (First Revision) |
- |
7600 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 1.2(Types) |
- |
0 |
|
- |
| 7.0(DIRECTION OF ROTATION) |
- |
0 |
|
- |
| 12.2(Performance Test
Verification of guarante
Cl.8 of IS 11346-2002
Rate of flow and head
Cl.8 of IS 11346-2002) |
- |
0 |
|
- |
| 12.2(Performance Test
Verification of guarante
Cl.8 of IS 11346-2002
Rate of flow and head
Cl.8 of IS 11346-2002) |
- |
0 |
|
- |
| 12.2(Performance Test
Verification of guarante
Cl.8 of IS 11346-2002
Efficiency
Cl.8.3 of IS 11346-2002) |
- |
0 |
|
- |
| 12.3(Primimg Test) |
- |
0 |
|
- |
| 13.2(General Requirements
Pump casing) |
- |
0 |
|
- |
| 13.3(General Requirements
Impeller) |
- |
0 |
|
- |
| 14.1(GUARANTEE) |
- |
0 |
|
- |
| 14.2(GUARANTEE) |
- |
0 |
|
- |
| 17.1(Marking) |
- |
0 |
|
- |
| 1.2(Types) |
- |
0 |
|
- |
| 7.0(DIRECTION OF ROTATION) |
- |
0 |
|
- |
| 12.2(Performance Test
Verification of guarante
Cl.8 of IS 11346-2002
Rate of flow and head
Cl.8 of IS 11346-2002) |
- |
0 |
|
- |
| 12.2(Performance Test
Verification of guarante
Cl.8 of IS 11346-2002
Rate of flow and head
Cl.8 of IS 11346-2002) |
- |
0 |
|
- |
| 12.2(Performance Test
Verification of guarante
Cl.8 of IS 11346-2002
Efficiency
Cl.8.3 of IS 11346-2002) |
- |
0 |
|
- |
| 12.3(Primimg Test) |
- |
0 |
|
- |
| 13.2(General Requirements
Pump casing) |
- |
0 |
|
- |
| 13.3(General Requirements
Impeller) |
- |
0 |
|
- |
| 14.1(GUARANTEE) |
- |
0 |
|
- |
| 14.2(GUARANTEE) |
- |
0 |
|
- |
| 17.1(Marking) |
- |
0 |
|
- |
| 17(Observation) |
- |
0 |
|
- |
| 12.2(Head, Flow, Current, Efficiency) |
- |
0 |
|
- |
| 13.2(Pressure) |
- |
0 |
|
- |
| 6(Observation) |
- |
0 |
|
- |
| 7(Observation) |
- |
0 |
|
- |
| 11(Observation) |
- |
0 |
|
- |
| 13(Observation) |
- |
0 |
|
- |
| 12.2(Time) |
- |
0 |
|
- |
| 17(Observation) |
- |
0 |
|
- |
| 12.2(Head, Flow, Current, Efficiency) |
- |
0 |
|
- |
| 13.2(Pressure) |
- |
0 |
|
- |
| 7(Observation) |
- |
0 |
|
- |
| 6(Observation) |
- |
0 |
|
- |
| 11(Observation) |
- |
0 |
|
- |
| 13(Observation) |
- |
0 |
|
- |
| 12.2(Time) |
- |
0 |
|
- |
| 17(Observation) |
- |
0 |
|
- |
| 12.2(Head, Flow, Current, Efficiency) |
- |
0 |
|
- |
| 13.2(Pressure) |
- |
0 |
|
- |
| 6(Observation) |
- |
0 |
|
- |
| 7(Observation) |
- |
0 |
|
- |
| 11(Observation) |
- |
0 |
|
- |
| 13(Observation) |
- |
0 |
|
- |
| 12.2(Time) |
- |
0 |
|
- |
| 17(Observation) |
- |
0 |
|
- |
| 12.2(Head, Flow, Current, Efficiency) |
- |
0 |
|
- |
| 13.2(Pressure) |
- |
0 |
|
- |
| 7(Observation) |
- |
0 |
|
- |
| 6(Observation) |
- |
0 |
|
- |
| 11(Observation) |
- |
0 |
|
- |
| 13(Observation) |
- |
0 |
|
- |
| 12.2(Time) |
- |
0 |
|
- |
|
28 Oct, 2028 |
- Included w.e.f. 15.09.2026
Exclusion: 6 (Observation) |
| 4 |
IS 2993 : Part 1 (2024) |
a.c. Motor Capacitors Part 1 General - Performance, Testing and Rating - Safety Requirements - Guidance for Installation and Operation ( Third Revision ) |
- |
90000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 5.1.1(General) |
- |
0 |
|
- |
| 5.5(Tangent of loss angle) |
- |
4000 |
|
- |
| 5.7("Voltage test between terminals
") |
- |
1500 |
|
- |
| 5.8(Voltage test between terminals and case) |
- |
1500 |
|
- |
| 5.9(Capacitance measurement) |
- |
4000 |
|
- |
| 5.9(Capacitance measurement) |
- |
4000 |
|
- |
| 5.1(Check of dimensions) |
- |
700 |
|
- |
| 5.11(Mechanical tests) |
- |
21700 |
|
- |
| 5.12(Sealing test) |
- |
1500 |
|
- |
| 5.13(Endurance test) |
- |
95000 |
|
Endurance Test -
Class D : Rs. 95,000/-,
Class C : Rs. 2,45,000/-,
Class B : Rs. 6.65,000/-,
Class A : Rs. 19,60,000/- |
| 5.14(Damp heat test) |
- |
25000 |
|
- |
| 5.15(Self-healing test) |
- |
3600 |
|
- |
| 5.16(Destruction test) |
- |
18500 |
|
- |
| 5.17(Resistance to heat, fire and tracking) |
- |
35000 |
|
- |
| 5.17.1(Ball-pressure test) |
- |
5000 |
|
- |
| 5.17.2(Glow-wire test) |
- |
15000 |
|
- |
| 5.17.3(Tracking test) |
- |
15000 |
|
- |
| 6.1(Maximum permissible voltage) |
- |
1000 |
|
- |
| 6.2("Maximum permissible current
") |
- |
1000 |
|
- |
| 6.3(Maximum permissible reactive output) |
- |
1000 |
|
- |
| 7(Safety requirements) |
- |
1000 |
|
- |
| 7.1(Requirements for Creepage distances and clearances) |
- |
1000 |
|
- |
| 7.3(Earth connections) |
- |
1000 |
|
- |
| 7.4(Discharge devices) |
- |
1000 |
|
- |
| 8(Marking) |
- |
700 |
|
- |
| 9.2.1(Measurements of working voltage) |
- |
1000 |
|
- |
| 9.2.2(Influence of capacitance) |
- |
1000 |
|
- |
| 9.3(Checking capacitor temperature) |
- |
1000 |
|
- |
| 9.4(Checking transients) |
- |
1000 |
|
- |
| 9.5(Leakage current) |
- |
1000 |
|
- |
| 7.2(Terminals and connecting cables) |
- |
1000 |
|
- |
| 5.1.1(General) |
- |
0 |
|
- |
| 5.5(Tangent of loss angle) |
- |
0 |
|
- |
| 5.7("Voltage test between terminals
") |
- |
0 |
|
- |
| 5.8(Voltage test between terminals and case) |
- |
0 |
|
- |
| 5.9(Capacitance measurement) |
- |
0 |
|
- |
| 5.9(Capacitance measurement) |
- |
0 |
|
- |
| 5.1(Check of dimensions) |
- |
0 |
|
- |
| 5.11(Mechanical tests) |
- |
0 |
|
- |
| 5.12(Sealing test) |
- |
0 |
|
- |
| 5.13(Endurance test) |
- |
0 |
|
- |
| 5.14(Damp heat test) |
- |
0 |
|
- |
| 5.15(Self-healing test) |
- |
0 |
|
- |
| 5.16(Destruction test) |
- |
0 |
|
- |
| 5.17(Resistance to heat, fire and tracking) |
- |
0 |
|
- |
| 5.17.1(Ball-pressure test) |
- |
0 |
|
- |
| 5.17.2(Glow-wire test) |
- |
0 |
|
- |
| 5.17.3(Tracking test) |
- |
0 |
|
- |
| 6.1(Maximum permissible voltage) |
- |
0 |
|
- |
| 6.2("Maximum permissible current
") |
- |
0 |
|
- |
| 6.3(Maximum permissible reactive output) |
- |
0 |
|
- |
| 7(Safety requirements) |
- |
0 |
|
- |
| 7.1(Requirements for Creepage distances and clearances) |
- |
0 |
|
- |
| 7.3(Earth connections) |
- |
0 |
|
- |
| 7.4(Discharge devices) |
- |
0 |
|
- |
| 8(Marking) |
- |
0 |
|
- |
| 9.2.1(Measurements of working voltage) |
- |
0 |
|
- |
| 9.2.2(Influence of capacitance) |
- |
0 |
|
- |
| 9.3(Checking capacitor temperature) |
- |
0 |
|
- |
| 9.4(Checking transients) |
- |
0 |
|
- |
| 9.5(Leakage current) |
- |
0 |
|
- |
| 7.2(Terminals and connecting cables) |
- |
0 |
|
- |
| 5.1.1(General) |
- |
0 |
|
- |
| 5.5(Tangent of loss angle) |
- |
0.02 |
|
- |
| 5.7("Voltage test between terminals
") |
- |
0.02 |
|
- |
| 5.8(Voltage test between terminals and case) |
- |
0 |
|
- |
| 5.9(Capacitance measurement) |
- |
0 |
|
- |
| 5.9(Capacitance measurement) |
- |
0 |
|
- |
| 5.1(Check of dimensions) |
- |
0 |
|
- |
| 5.11(Mechanical tests) |
- |
0 |
|
- |
| 5.12(Sealing test) |
- |
0 |
|
- |
| 5.13(Endurance test) |
- |
0 |
|
- |
| 5.14(Damp heat test) |
- |
0.01 |
|
- |
| 5.15(Self-healing test) |
- |
0 |
|
- |
| 5.16(Destruction test) |
- |
0 |
|
- |
| 5.17(Resistance to heat, fire and tracking) |
- |
0 |
|
- |
| 5.17.1(Ball-pressure test) |
- |
0 |
|
- |
| 5.17.2(Glow-wire test) |
- |
0 |
|
- |
| 5.17.3(Tracking test) |
- |
0 |
|
- |
| 6.1(Maximum permissible voltage) |
- |
0 |
|
- |
| 6.2("Maximum permissible current
") |
- |
0 |
|
- |
| 6.3(Maximum permissible reactive output) |
- |
0 |
|
- |
| 7(Safety requirements) |
- |
0 |
|
- |
| 7.1(Requirements for Creepage distances and clearances) |
- |
0 |
|
- |
| 7.3(Earth connections) |
- |
0 |
|
- |
| 7.4(Discharge devices) |
- |
0 |
|
- |
| 8(Marking) |
- |
0 |
|
- |
| 9.2.1(Measurements of working voltage) |
- |
0 |
|
- |
| 9.2.2(Influence of capacitance) |
- |
0 |
|
- |
| 9.3(Checking capacitor temperature) |
- |
0 |
|
- |
| 9.4(Checking transients) |
- |
0.02 |
|
- |
| 9.5(Leakage current) |
- |
0 |
|
- |
| 7.2(Terminals and connecting cables) |
- |
0 |
|
- |
|
28 Oct, 2028 |
- Included w.e.f-08.07.2026 |
| 5 |
IS 2347 (2023) |
DOMESTIC PRESSURE COOKER � SPECIFICATION |
- |
30500 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4.1(Gross capacity) |
- |
500 |
|
- |
| 4.2(Body Capacity) |
- |
500 |
|
- |
| 5.1(Body, Lid, Containers and Grid) |
- |
650 |
|
- |
| 5.1.2(Body and Lid ) |
- |
650 |
|
- |
| 5.1.3(Stainless steel pressure cooker) |
- |
650 |
|
- |
| 5.1.4(Aluminium cooker ) |
- |
650 |
|
- |
| 5.2(Safety Relief Device) |
- |
750 |
|
- |
| 5.3(Gasket) |
- |
200 |
|
- |
| 5.4(Handles and Knobs) |
- |
500 |
|
- |
| 5.5(Pressure Regulating Device ) |
- |
500 |
|
- |
| 5.6(Vent Seal Pin for Pressure Regulating Device ) |
- |
650 |
|
- |
| 5.7(Vent Pipe ) |
- |
400 |
|
- |
| 5.8(Vent Pipe Nut ) |
- |
400 |
|
- |
| 5.9(Spring ) |
- |
400 |
|
- |
| 5.1(Material of Rim ) |
- |
400 |
|
- |
| 5.11(Visual Pressure Indicator) |
- |
500 |
|
- |
| 5.12(Gasket Release System) |
- |
500 |
|
- |
| 6(Construction) |
- |
500 |
|
- |
| 7(Workmanship and Finish ) |
- |
500 |
|
- |
| 8.1(Air Pressure Test ) |
- |
1000 |
|
- |
| 8.2(Proof Pressure Test ) |
- |
500 |
|
- |
| 8.3(Operating Test for Pressure Regulating Device ) |
- |
500 |
|
- |
| 8.4(Test for Safety Relief Device ) |
- |
750 |
|
- |
| 8.5(Bursting Pressure Test ) |
- |
1000 |
|
- |
| 8.6(Test for Removal of Lid under Pressure ) |
- |
750 |
|
- |
| 8.8(Composite Cooker Base ) |
- |
1000 |
|
- |
| 8.9(Aluminium induction compatible Base ) |
- |
2500 |
|
- |
| 8.1(Handles of cooker ) |
- |
8500 |
|
- |
| 8.11(External Coating) |
- |
500 |
|
- |
| 8.12(Internal Coating ) |
- |
500 |
|
- |
| 8.14(Ply construction cooker Body ) |
- |
1500 |
|
- |
| 8.15.1(Fragmentation Test ) |
- |
250 |
|
- |
| 8.15.2(Ball Drop Test ) |
- |
250 |
|
- |
| 8.15.3(Thermal Shock Test ) |
- |
500 |
|
- |
| 8.15.4(Free Fall Test) |
- |
500 |
|
- |
| 8.17(Test for Effectiveness for Induction Bottom) |
- |
500 |
|
- |
| 11(Marking ) |
- |
100 |
|
- |
| 4(Capacity) |
- |
0 |
|
- |
| 4.2(Body Capacity) |
- |
0 |
|
- |
| 5.1.1(Body, Lid, Containers and Grid) |
- |
0 |
|
- |
| 5.1.2(Body, Lid, Containers and Grid) |
- |
0 |
|
- |
| 5.1.3(Body, Lid, Containers and Grid) |
- |
0 |
|
- |
| 5.1.4(Body, Lid, Containers and Grid) |
- |
0 |
|
- |
| 5.1.5(Body, Lid, Containers and Grid) |
- |
0 |
|
- |
| 5.2.1(Destructive Type Safety Relief Device) |
- |
0 |
|
- |
| 5.2.2(Resettable Type Safety Relief Device) |
- |
0 |
|
- |
| 5.3(Gasket) |
- |
0 |
|
- |
| 5.4(Handles and Knobs) |
- |
0 |
|
- |
| 5.5(Pressure Regulating Device) |
- |
0 |
|
- |
| 5.6(Vent Seal Pin for Pressure Regulating Device) |
- |
0 |
|
- |
| 5.7(Vent Pipe) |
- |
0 |
|
- |
| 5.8(Vent Pipe Nut) |
- |
0 |
|
- |
| 5.9(Spring) |
- |
0 |
|
- |
| 5.10(Spring) |
- |
0 |
|
- |
| 5.11(Visual Pressure Indicator) |
- |
0 |
|
- |
| 5.12(Gasket Release System) |
- |
0 |
|
- |
| 6(CONSTRUCTION) |
- |
0 |
|
- |
| 6.1(Pressure Regulating Device) |
- |
0 |
|
- |
| 6.1.1(Pressure Regulating Device) |
- |
0 |
|
- |
| 6.1.1(Minimum Inside diameter of Vent Pipe.) |
- |
0 |
|
- |
| 6.1.2(Pressure Regulating Device) |
- |
0 |
|
- |
| 6.1.3(Pressure Regulating Device) |
- |
0 |
|
- |
| 6.1.4(Pressure Regulating Device) |
- |
0 |
|
- |
| 6.1.5(Pressure Regulating Device) |
- |
0 |
|
- |
| 6.1.6(Pressure Regulating Device) |
- |
0 |
|
- |
| 6.2(Safety Relief Device) |
- |
0 |
|
- |
| 6.2.1(Safety Relief Device) |
- |
0 |
|
- |
| 6.2.2(Safety Relief Device) |
- |
0 |
|
- |
| 6.2.3(Safety Relief Device) |
- |
0 |
|
- |
| 6.3.1(Temperature Responsive Safety Relief Device) |
- |
0 |
|
- |
| 6.3.2(Temperature Responsive Safety Relief Device) |
- |
0 |
|
- |
| 6.3.3(Temperature Responsive Safety Relief Device) |
- |
0 |
|
- |
| 6.4.1(Handles and Knobs) |
- |
0 |
|
- |
| 6.4.1.1(Handles and Knobs) |
- |
0 |
|
- |
| 6.4.2(Handles and Knobs) |
- |
0 |
|
- |
| 6.4.2.1(Handles and Knobs) |
- |
0 |
|
- |
| 6.6(CONSTRUCTION) |
- |
0 |
|
- |
| 6.7(Internal Level Marking) |
- |
0 |
|
- |
| 6.8(Internal Level Marking) |
- |
0 |
|
- |
| 7.1(WORKMANSHIP AND FINISH) |
- |
0 |
|
- |
| 7.2(WORKMANSHIP AND FINISH) |
- |
0 |
|
- |
| 8.17(Test for Effectiveness for Induction Bottom) |
- |
0 |
|
- |
| 8.16(PRD with chain) |
- |
0 |
|
- |
| 8.15.4.2(Glass lid without rim) |
- |
0 |
|
- |
| 8.15.4.1("Free Fall Test ( Glass lid with rim)
") |
- |
0 |
|
- |
| 8.15.3(Thermal Shock Test on Tempered Glass lid) |
- |
0 |
|
- |
| 8.15.2(Ball Drop Test on Tempered Glass lid) |
- |
0 |
|
- |
| 8.15.1(Fragmentation Test on Tempered Glass lid) |
- |
0 |
|
- |
| 8.14(3 ply construction cooker body) |
- |
0 |
|
- |
| 8.12(Internal Coating) |
- |
0 |
|
- |
| 7.3(WORKMANSHIP AND FINISH) |
- |
0 |
|
- |
| 7.4(WORKMANSHIP AND FINISH) |
- |
0 |
|
- |
| 8.1(Air Pressure Test) |
- |
0 |
|
- |
| 8.2(Proof Pressure Test) |
- |
0 |
|
- |
| 8.3.1(Operating Test for Pressure Regulating Device) |
- |
0 |
|
- |
| 8.4.1(Test for Safety Relief Device) |
- |
0 |
|
- |
| 8.4.2(Test for Safety Relief Device) |
- |
0 |
|
- |
| 8.4.2 NOTE(Test for Safety Relief Device) |
- |
0 |
|
- |
| 8.5(Bursting Pressure Test) |
- |
0 |
|
- |
| 8.6.1(Tests for Removal of Lid under Pressure For Outer Lid Cooker) |
- |
0 |
|
- |
| 8.6.2(Tests for Removal of Lid under Pressure For inner Lid Cooker) |
- |
0 |
|
- |
| 8.6.3(Tests for Removal of Lid under Pressure: For Cooker Fastened by Screw Clamps or Any Other Locking Device) |
- |
0 |
|
- |
| 8.8(Test for stainless steel cookers) |
- |
0 |
|
- |
| 8.9("For stainless steel, aluminium induction
compatible base and 3 ply cooker") |
- |
0 |
|
- |
| 8.10(Testing of Handles of the cooker) |
- |
0 |
|
- |
| 8.10 Note 3(Testing of Handles of the cooker) |
- |
0 |
|
- |
| 8.10 Note 4(Testing of Handles of the cooker) |
- |
0 |
|
- |
| 8.10 Note 5(Testing of Handles of the cooker) |
- |
0 |
|
- |
| 8.10 Note 6(Testing of Handles of the cooker) |
- |
0 |
|
- |
| 8.11.1(External Coating) |
- |
0 |
|
- |
| 8.7(Test for Spring Loaded Mechanism ) |
- |
0 |
|
- |
| 6.5(CONSTRUCTION) |
- |
0 |
|
- |
| 8.13(Integral electrical heating) |
- |
0 |
|
- |
| 12(Packing ) |
- |
0 |
|
- |
| 8.10.1(Testing of Handles of the cooker) |
- |
0 |
|
- |
| 8.13(Pressure cooker with integral electrical heating) |
- |
0 |
|
- |
| Cl 18.15.5 (Amendment No.2)(Nominal thickness of glass lid) |
- |
0 |
|
- |
| 8.7(Test for Spring Loaded Mechanism) |
- |
0 |
|
- |
| 4.1(Gross capacity) |
- |
0 |
|
- |
| 4.2(Body Capacity) |
- |
0 |
|
- |
| 5.1(Body, Lid, Containers and Grid) |
- |
0 |
|
- |
| 5.1.2(Body and Lid ) |
- |
0 |
|
- |
| 5.1.3(Stainless steel pressure cooker) |
- |
0 |
|
- |
| 5.1.4(Aluminium cooker ) |
- |
0 |
|
- |
| 5.2(Safety Relief Device) |
- |
0 |
|
- |
| 5.3(Gasket) |
- |
0 |
|
- |
| 5.4(Handles and Knobs) |
- |
0 |
|
- |
| 5.5(Pressure Regulating Device ) |
- |
0 |
|
- |
| 5.6(Vent Seal Pin for Pressure Regulating Device ) |
- |
0 |
|
- |
| 5.7(Vent Pipe ) |
- |
0 |
|
- |
| 5.8(Vent Pipe Nut ) |
- |
0 |
|
- |
| 5.9(Spring ) |
- |
0 |
|
- |
| 5.1(Material of Rim ) |
- |
0 |
|
- |
| 5.11(Visual Pressure Indicator) |
- |
0 |
|
- |
| 5.12(Gasket Release System) |
- |
0 |
|
- |
| 6(Construction) |
- |
0 |
|
- |
| 7(Workmanship and Finish ) |
- |
0 |
|
- |
| 8.1(Air Pressure Test ) |
- |
0 |
|
- |
| 8.2(Proof Pressure Test ) |
- |
0 |
|
- |
| 8.3(Operating Test for Pressure Regulating Device ) |
- |
0 |
|
- |
| 8.4(Test for Safety Relief Device ) |
- |
0 |
|
- |
| 8.5(Bursting Pressure Test ) |
- |
0 |
|
- |
| 8.6(Test for Removal of Lid under Pressure ) |
- |
0 |
|
- |
| 8.8(Composite Cooker Base ) |
- |
0 |
|
- |
| 8.9(Aluminium induction compatible Base ) |
- |
0 |
|
- |
| 8.1(Handles of cooker ) |
- |
0 |
|
- |
| 8.11(External Coating) |
- |
0 |
|
- |
| 8.12(Internal Coating ) |
- |
0 |
|
- |
| 8.14(Ply construction cooker Body ) |
- |
0 |
|
- |
| 8.15.1(Fragmentation Test ) |
- |
0 |
|
- |
| 8.15.2(Ball Drop Test ) |
- |
0 |
|
- |
| 8.15.3(Thermal Shock Test ) |
- |
0 |
|
- |
| 8.15.4(Free Fall Test) |
- |
0 |
|
- |
| 8.17(Test for Effectiveness for Induction Bottom) |
- |
0 |
|
- |
| 11(Marking ) |
- |
0 |
|
- |
| 4(Capacity) |
- |
0 |
|
- |
| 4.2(Body Capacity) |
- |
0 |
|
- |
| 5.1.1(Body, Lid, Containers and Grid) |
- |
0 |
|
- |
| 5.1.2(Body, Lid, Containers and Grid) |
- |
0 |
|
- |
| 5.1.3(Body, Lid, Containers and Grid) |
- |
0 |
|
- |
| 5.1.4(Body, Lid, Containers and Grid) |
- |
0 |
|
- |
| 5.1.5(Body, Lid, Containers and Grid) |
- |
0 |
|
- |
| 5.2.1(Destructive Type Safety Relief Device) |
- |
0 |
|
- |
| 5.2.2(Resettable Type Safety Relief Device) |
- |
0 |
|
- |
| 5.3(Gasket) |
- |
0 |
|
- |
| 5.4(Handles and Knobs) |
- |
0 |
|
- |
| 5.5(Pressure Regulating Device) |
- |
0 |
|
- |
| 5.6(Vent Seal Pin for Pressure Regulating Device) |
- |
0 |
|
- |
| 5.7(Vent Pipe) |
- |
0 |
|
- |
| 5.8(Vent Pipe Nut) |
- |
0 |
|
- |
| 5.9(Spring) |
- |
0 |
|
- |
| 5.10(Spring) |
- |
0 |
|
- |
| 5.11(Visual Pressure Indicator) |
- |
0 |
|
- |
| 5.12(Gasket Release System) |
- |
0 |
|
- |
| 6(CONSTRUCTION) |
- |
0 |
|
- |
| 6.1(Pressure Regulating Device) |
- |
0 |
|
- |
| 6.1.1(Pressure Regulating Device) |
- |
0 |
|
- |
| 6.1.1(Minimum Inside diameter of Vent Pipe.) |
- |
0 |
|
- |
| 6.1.2(Pressure Regulating Device) |
- |
0 |
|
- |
| 6.1.3(Pressure Regulating Device) |
- |
0 |
|
- |
| 6.1.4(Pressure Regulating Device) |
- |
0 |
|
- |
| 6.1.5(Pressure Regulating Device) |
- |
0 |
|
- |
| 6.1.6(Pressure Regulating Device) |
- |
0 |
|
- |
| 6.2(Safety Relief Device) |
- |
0 |
|
- |
| 6.2.1(Safety Relief Device) |
- |
0 |
|
- |
| 6.2.2(Safety Relief Device) |
- |
0 |
|
- |
| 6.2.3(Safety Relief Device) |
- |
0 |
|
- |
| 6.3.1(Temperature Responsive Safety Relief Device) |
- |
0 |
|
- |
| 6.3.2(Temperature Responsive Safety Relief Device) |
- |
0 |
|
- |
| 6.3.3(Temperature Responsive Safety Relief Device) |
- |
0 |
|
- |
| 6.4.1(Handles and Knobs) |
- |
0 |
|
- |
| 6.4.1.1(Handles and Knobs) |
- |
0 |
|
- |
| 6.4.2(Handles and Knobs) |
- |
0 |
|
- |
| 6.4.2.1(Handles and Knobs) |
- |
0 |
|
- |
| 6.6(CONSTRUCTION) |
- |
0 |
|
- |
| 6.7(Internal Level Marking) |
- |
0 |
|
- |
| 6.8(Internal Level Marking) |
- |
0 |
|
- |
| 7.1(WORKMANSHIP AND FINISH) |
- |
0 |
|
- |
| 7.2(WORKMANSHIP AND FINISH) |
- |
0 |
|
- |
| 8.17(Test for Effectiveness for Induction Bottom) |
- |
0 |
|
- |
| 8.16(PRD with chain) |
- |
0 |
|
- |
| 8.15.4.2(Glass lid without rim) |
- |
0 |
|
- |
| 8.15.4.1("Free Fall Test ( Glass lid with rim)
") |
- |
0 |
|
- |
| 8.15.3(Thermal Shock Test on Tempered Glass lid) |
- |
0 |
|
- |
| 8.15.2(Ball Drop Test on Tempered Glass lid) |
- |
0 |
|
- |
| 8.15.1(Fragmentation Test on Tempered Glass lid) |
- |
0 |
|
- |
| 8.14(3 ply construction cooker body) |
- |
0 |
|
- |
| 8.12(Internal Coating) |
- |
0 |
|
- |
| 7.3(WORKMANSHIP AND FINISH) |
- |
0 |
|
- |
| 7.4(WORKMANSHIP AND FINISH) |
- |
0 |
|
- |
| 8.1(Air Pressure Test) |
- |
0 |
|
- |
| 8.2(Proof Pressure Test) |
- |
0 |
|
- |
| 8.3.1(Operating Test for Pressure Regulating Device) |
- |
0 |
|
- |
| 8.4.1(Test for Safety Relief Device) |
- |
0 |
|
- |
| 8.4.2(Test for Safety Relief Device) |
- |
0 |
|
- |
| 8.4.2 NOTE(Test for Safety Relief Device) |
- |
0 |
|
- |
| 8.5(Bursting Pressure Test) |
- |
0 |
|
- |
| 8.6.1(Tests for Removal of Lid under Pressure For Outer Lid Cooker) |
- |
0 |
|
- |
| 8.6.2(Tests for Removal of Lid under Pressure For inner Lid Cooker) |
- |
0 |
|
- |
| 8.6.3(Tests for Removal of Lid under Pressure: For Cooker Fastened by Screw Clamps or Any Other Locking Device) |
- |
0 |
|
- |
| 8.8(Test for stainless steel cookers) |
- |
0 |
|
- |
| 8.9("For stainless steel, aluminium induction
compatible base and 3 ply cooker") |
- |
0 |
|
- |
| 8.10(Testing of Handles of the cooker) |
- |
0 |
|
- |
| 8.10 Note 3(Testing of Handles of the cooker) |
- |
0 |
|
- |
| 8.10 Note 4(Testing of Handles of the cooker) |
- |
0 |
|
- |
| 8.10 Note 5(Testing of Handles of the cooker) |
- |
0 |
|
- |
| 8.10 Note 6(Testing of Handles of the cooker) |
- |
0 |
|
- |
| 8.11.1(External Coating) |
- |
0 |
|
- |
| 8.7(Test for Spring Loaded Mechanism ) |
- |
0 |
|
- |
| 6.5(CONSTRUCTION) |
- |
0 |
|
- |
| 8.13(Integral electrical heating) |
- |
0 |
|
- |
| 12(Packing ) |
- |
0 |
|
- |
| 8.10.1(Testing of Handles of the cooker) |
- |
0 |
|
- |
| 8.13(Pressure cooker with integral electrical heating) |
- |
0 |
|
- |
| Cl 18.15.5 (Amendment No.2)(Nominal thickness of glass lid) |
- |
0 |
|
- |
| 8.7(Test for Spring Loaded Mechanism) |
- |
0 |
|
- |
|
28 Oct, 2028 |
- Included w.e.f. 05.06.2026 |
| 6 |
IS 7538 (1996) |
Three - Phase squirrel cage induction motors for centrifugal pumps for agricultural application - Specification (First Revision) |
- |
4400 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 5(ENCLOSURES) |
- |
0 |
|
Rs.4050/- 3.7kW
Rs.4150/-3.7kW to7.5kW
Rs.5000/-7.5kW to11kW
Rs.6100/-11kW to15kW |
| 6(COOLING) |
- |
0 |
|
Rs.4050/- 3.7kW
Rs.4150/-3.7kW to7.5kW
Rs.5000/-7.5kW to11kW
Rs.6100/-11kW to15kW |
| 7(MATERIALS) |
- |
0 |
|
Rs.4050/- 3.7kW
Rs.4150/-3.7kW to7.5kW
Rs.5000/-7.5kW to11kW
Rs.6100/-11kW to15kW |
| 8.1(Rated Voltage) |
- |
0 |
|
Rs.4050/- 3.7kW
Rs.4150/-3.7kW to7.5kW
Rs.5000/-7.5kW to11kW
Rs.6100/-11kW to15kW |
| 8.2(Rated Frequency) |
- |
0 |
|
Rs.4050/- 3.7kW
Rs.4150/-3.7kW to7.5kW
Rs.5000/-7.5kW to11kW
Rs.6100/-11kW to15kW |
| 8.3(Rated Outputs) |
- |
0 |
|
Rs.4050/- 3.7kW
Rs.4150/-3.7kW to7.5kW
Rs.5000/-7.5kW to11kW
Rs.6100/-11kW to15kW |
| 9(DIMENSIONS- H : Nominal ) |
- |
0 |
|
Rs.4050/- 3.7kW
Rs.4150/-3.7kW to7.5kW
Rs.5000/-7.5kW to11kW
Rs.6100/-11kW to15kW |
| 9(DIMENSIONS- H : Deviation ) |
- |
0 |
|
Rs.4050/- 3.7kW
Rs.4150/-3.7kW to7.5kW
Rs.5000/-7.5kW to11kW
Rs.6100/-11kW to15kW |
| 9(DIMENSIONS- A) |
- |
0 |
|
Rs.4050/- 3.7kW
Rs.4150/-3.7kW to7.5kW
Rs.5000/-7.5kW to11kW
Rs.6100/-11kW to15kW |
| 9(DIMENSIONS- B) |
- |
0 |
|
Rs.4050/- 3.7kW
Rs.4150/-3.7kW to7.5kW
Rs.5000/-7.5kW to11kW
Rs.6100/-11kW to15kW |
| 9(DIMENSIONS- C) |
- |
0 |
|
Rs.4050/- 3.7kW
Rs.4150/-3.7kW to7.5kW
Rs.5000/-7.5kW to11kW
Rs.6100/-11kW to15kW |
| 9(DIMENSIONS- K+ : Nominal ) |
- |
0 |
|
Rs.4050/- 3.7kW
Rs.4150/-3.7kW to7.5kW
Rs.5000/-7.5kW to11kW
Rs.6100/-11kW to15kW |
| 9(DIMENSIONS- K+ : Tolerance ) |
- |
0 |
|
Rs.4050/- 3.7kW
Rs.4150/-3.7kW to7.5kW
Rs.5000/-7.5kW to11kW
Rs.6100/-11kW to15kW |
| 9(DIMENSIONS- Bolt or Screw) |
- |
0 |
|
Rs.4050/- 3.7kW
Rs.4150/-3.7kW to7.5kW
Rs.5000/-7.5kW to11kW
Rs.6100/-11kW to15kW |
| 9(DIMENSIONS- M) |
- |
0 |
|
Rs.4050/- 3.7kW
Rs.4150/-3.7kW to7.5kW
Rs.5000/-7.5kW to11kW
Rs.6100/-11kW to15kW |
| 9(DIMENSIONS- N) |
- |
0 |
|
Rs.4050/- 3.7kW
Rs.4150/-3.7kW to7.5kW
Rs.5000/-7.5kW to11kW
Rs.6100/-11kW to15kW |
| 9(DIMENSIONS- P) |
- |
0 |
|
Rs.4050/- 3.7kW
Rs.4150/-3.7kW to7.5kW
Rs.5000/-7.5kW to11kW
Rs.6100/-11kW to15kW |
| 9(DIMENSIONS- S) |
- |
0 |
|
Rs.4050/- 3.7kW
Rs.4150/-3.7kW to7.5kW
Rs.5000/-7.5kW to11kW
Rs.6100/-11kW to15kW |
| 9(DIMENSIONS- T) |
- |
0 |
|
Rs.4050/- 3.7kW
Rs.4150/-3.7kW to7.5kW
Rs.5000/-7.5kW to11kW
Rs.6100/-11kW to15kW |
| 9(DIMENSIONS- LA) |
- |
0 |
|
Rs.4050/- 3.7kW
Rs.4150/-3.7kW to7.5kW
Rs.5000/-7.5kW to11kW
Rs.6100/-11kW to15kW |
| 9(DIMENSIONS- Depth of tapped Hole) |
- |
0 |
|
Rs.4050/- 3.7kW
Rs.4150/-3.7kW to7.5kW
Rs.5000/-7.5kW to11kW
Rs.6100/-11kW to15kW |
| 10(TYPE OF DUTY AND CLASSES OF
RATING) |
- |
0 |
|
Rs.4050/- 3.7kW
Rs.4150/-3.7kW to7.5kW
Rs.5000/-7.5kW to11kW
Rs.6100/-11kW to15kW |
| 11(PROVISION FOR EARTHING) |
- |
0 |
|
Rs.4050/- 3.7kW
Rs.4150/-3.7kW to7.5kW
Rs.5000/-7.5kW to11kW
Rs.6100/-11kW to15kW |
| 12.1, Table 1 to Table 6(Minimum full load speed) |
- |
0 |
|
Rs.4050/- 3.7kW
Rs.4150/-3.7kW to7.5kW
Rs.5000/-7.5kW to11kW
Rs.6100/-11kW to15kW |
| 12.1, Table 1 to Table 6(maximum full load
current) |
- |
0 |
|
Rs.4050/- 3.7kW
Rs.4150/-3.7kW to7.5kW
Rs.5000/-7.5kW to11kW
Rs.6100/-11kW to15kW |
| 12.1, Table 1 to Table 6(minimum starting torque/ breakaway torque ) |
- |
0 |
|
Rs.4050/- 3.7kW
Rs.4150/-3.7kW to7.5kW
Rs.5000/-7.5kW to11kW
Rs.6100/-11kW to15kW |
| 12.1, Table 1 to Table 6(nominal efficiency) |
- |
0 |
|
Rs.4050/- 3.7kW
Rs.4150/-3.7kW to7.5kW
Rs.5000/-7.5kW to11kW
Rs.6100/-11kW to15kW |
| 12.1, Table 1 to Table 6(nominal efficiency at 75% rated load) |
- |
0 |
|
Rs.4050/- 3.7kW
Rs.4150/-3.7kW to7.5kW
Rs.5000/-7.5kW to11kW
Rs.6100/-11kW to15kW |
| 13.1(OVERLOAD:Momentary Excess Torque) |
- |
0 |
|
Rs.4050/- 3.7kW
Rs.4150/-3.7kW to7.5kW
Rs.5000/-7.5kW to11kW
Rs.6100/-11kW to15kW |
| 13.2(OVERLOAD:Sustained Overloads) |
- |
0 |
|
Rs.4050/- 3.7kW
Rs.4150/-3.7kW to7.5kW
Rs.5000/-7.5kW to11kW
Rs.6100/-11kW to15kW |
| 14(LIMITS OF TEMPERATURES AND
TEMPERATURE-RISE) |
- |
0 |
|
Rs.4050/- 3.7kW
Rs.4150/-3.7kW to7.5kW
Rs.5000/-7.5kW to11kW
Rs.6100/-11kW to15kW |
| 15(LIMITS OF VIBRATION SEVERITY) |
- |
2400 |
|
Rs.4050/- 3.7kW
Rs.4150/-3.7kW to7.5kW
Rs.5000/-7.5kW to11kW
Rs.6100/-11kW to15kW |
| 16(LIMITS OF NOISE LEVELS) |
- |
1100 |
|
Rs.4050/- 3.7kW
Rs.4150/-3.7kW to7.5kW
Rs.5000/-7.5kW to11kW
Rs.6100/-11kW to15kW |
| 17.1(Efficiency) |
- |
0 |
|
Rs.4050/- 3.7kW
Rs.4150/-3.7kW to7.5kW
Rs.5000/-7.5kW to11kW
Rs.6100/-11kW to15kW |
| 17.2(Power Factor) |
- |
0 |
|
Rs.4050/- 3.7kW
Rs.4150/-3.7kW to7.5kW
Rs.5000/-7.5kW to11kW
Rs.6100/-11kW to15kW |
| 18(TOLERANCES) |
- |
0 |
|
Rs.4050/- 3.7kW
Rs.4150/-3.7kW to7.5kW
Rs.5000/-7.5kW to11kW
Rs.6100/-11kW to15kW |
| 19.1(TERMINAL BOX) |
- |
0 |
|
Rs.4050/- 3.7kW
Rs.4150/-3.7kW to7.5kW
Rs.5000/-7.5kW to11kW
Rs.6100/-11kW to15kW |
| 19.1.1(TERMINAL
MARKINGS) |
- |
0 |
|
Rs.4050/- 3.7kW
Rs.4150/-3.7kW to7.5kW
Rs.5000/-7.5kW to11kW
Rs.6100/-11kW to15kW |
| 20.1( MARKING) |
- |
0 |
|
Rs.4050/- 3.7kW
Rs.4150/-3.7kW to7.5kW
Rs.5000/-7.5kW to11kW
Rs.6100/-11kW to15kW |
| 20.2(BIS Certification Marking) |
- |
0 |
|
Rs.4050/- 3.7kW
Rs.4150/-3.7kW to7.5kW
Rs.5000/-7.5kW to11kW
Rs.6100/-11kW to15kW |
| 22.3.1 b)(Measurement of stator resistance) |
- |
0 |
|
Rs.4050/- 3.7kW
Rs.4150/-3.7kW to7.5kW
Rs.5000/-7.5kW to11kW
Rs.6100/-11kW to15kW |
| 23.1(TEMPERATURE-RISE TEST : Test at Rated Voltage) |
- |
0 |
|
Rs.4050/- 3.7kW
Rs.4150/-3.7kW to7.5kW
Rs.5000/-7.5kW to11kW
Rs.6100/-11kW to15kW |
| 23.2(TEMPERATURE-RISE TEST: Test at Reduced Voltage) |
- |
0 |
|
Rs.4050/- 3.7kW
Rs.4150/-3.7kW to7.5kW
Rs.5000/-7.5kW to11kW
Rs.6100/-11kW to15kW |
| 24.1(No-load running of motor and reading of
' voltage) |
- |
0 |
|
Rs.4050/- 3.7kW
Rs.4150/-3.7kW to7.5kW
Rs.5000/-7.5kW to11kW
Rs.6100/-11kW to15kW |
| 24.1(No-load running of motor and reading of
' current ) |
- |
0 |
|
Rs.4050/- 3.7kW
Rs.4150/-3.7kW to7.5kW
Rs.5000/-7.5kW to11kW
Rs.6100/-11kW to15kW |
| 24.1(No-load running of motor and reading of
' power input ) |
- |
0 |
|
Rs.4050/- 3.7kW
Rs.4150/-3.7kW to7.5kW
Rs.5000/-7.5kW to11kW
Rs.6100/-11kW to15kW |
| 24.1(No-load running of motor and reading of
' speed ) |
- |
0 |
|
Rs.4050/- 3.7kW
Rs.4150/-3.7kW to7.5kW
Rs.5000/-7.5kW to11kW
Rs.6100/-11kW to15kW |
| 24.2(Reduced Voltage Running Up Test) |
- |
0 |
|
Rs.4050/- 3.7kW
Rs.4150/-3.7kW to7.5kW
Rs.5000/-7.5kW to11kW
Rs.6100/-11kW to15kW |
| 24.3(Locked Rotor Test:The readings of the input
current) |
- |
0 |
|
Rs.4050/- 3.7kW
Rs.4150/-3.7kW to7.5kW
Rs.5000/-7.5kW to11kW
Rs.6100/-11kW to15kW |
| 24.3(Locked Rotor Test:The readings of the input
power) |
- |
0 |
|
Rs.4050/- 3.7kW
Rs.4150/-3.7kW to7.5kW
Rs.5000/-7.5kW to11kW
Rs.6100/-11kW to15kW |
| 24.3(Locked Rotor Test:The readings of the breakaway rotor torque) |
- |
0 |
|
Rs.4050/- 3.7kW
Rs.4150/-3.7kW to7.5kW
Rs.5000/-7.5kW to11kW
Rs.6100/-11kW to15kW |
| 24.4(Full Load Test : voltage) |
- |
0 |
|
Rs.4050/- 3.7kW
Rs.4150/-3.7kW to7.5kW
Rs.5000/-7.5kW to11kW
Rs.6100/-11kW to15kW |
| 24.4(Full Load Test : Power input ) |
- |
0 |
|
Rs.4050/- 3.7kW
Rs.4150/-3.7kW to7.5kW
Rs.5000/-7.5kW to11kW
Rs.6100/-11kW to15kW |
| 24.4(Full Load Test : current ) |
- |
0 |
|
Rs.4050/- 3.7kW
Rs.4150/-3.7kW to7.5kW
Rs.5000/-7.5kW to11kW
Rs.6100/-11kW to15kW |
| 24.4(Full Load Test : speed) |
- |
0 |
|
Rs.4050/- 3.7kW
Rs.4150/-3.7kW to7.5kW
Rs.5000/-7.5kW to11kW
Rs.6100/-11kW to15kW |
| 24.5(Test for efficiency at reduced load) |
- |
0 |
|
Rs.4050/- 3.7kW
Rs.4150/-3.7kW to7.5kW
Rs.5000/-7.5kW to11kW
Rs.6100/-11kW to15kW |
| 25(HIGH-VOLTAGE TEST) |
- |
0 |
|
Rs.4050/- 3.7kW
Rs.4150/-3.7kW to7.5kW
Rs.5000/-7.5kW to11kW
Rs.6100/-11kW to15kW |
| 26(INSULATION-RESISTANCE TEST) |
- |
0 |
|
Rs.4050/- 3.7kW
Rs.4150/-3.7kW to7.5kW
Rs.5000/-7.5kW to11kW
Rs.6100/-11kW to15kW |
| 27(OVERSPEED TEST) |
- |
0 |
|
Rs.4050/- 3.7kW
Rs.4150/-3.7kW to7.5kW
Rs.5000/-7.5kW to11kW
Rs.6100/-11kW to15kW |
| Site Conditions(Tested as per 4 of IS 325: 1996) |
- |
0 |
|
Rs.4050/- 3.7kW
Rs.4150/-3.7kW to7.5kW
Rs.5000/-7.5kW to11kW
Rs.6100/-11kW to15kW |
| 5(Enclosure) |
- |
10000 |
|
Rs.4050/- 3.7kW
Rs.4150/-3.7kW to7.5kW
Rs.5000/-7.5kW to11kW
Rs.6100/-11kW to15kW |
| 6(Cooling) |
- |
0 |
|
Rs.4050/- 3.7kW
Rs.4150/-3.7kW to7.5kW
Rs.5000/-7.5kW to11kW
Rs.6100/-11kW to15kW |
| 7(Materials) |
- |
0 |
|
Rs.4050/- 3.7kW
Rs.4150/-3.7kW to7.5kW
Rs.5000/-7.5kW to11kW
Rs.6100/-11kW to15kW |
| 8("Rated conditions of voltage, frequenecy and
output of motor ") |
- |
0 |
|
Rs.4050/- 3.7kW
Rs.4150/-3.7kW to7.5kW
Rs.5000/-7.5kW to11kW
Rs.6100/-11kW to15kW |
| 9(Dimensions) |
- |
0 |
|
Rs.4050/- 3.7kW
Rs.4150/-3.7kW to7.5kW
Rs.5000/-7.5kW to11kW
Rs.6100/-11kW to15kW |
| 10(Types of duty and classes of rating) |
- |
0 |
|
Rs.4050/- 3.7kW
Rs.4150/-3.7kW to7.5kW
Rs.5000/-7.5kW to11kW
Rs.6100/-11kW to15kW |
| 11(Provision for earthing) |
- |
0 |
|
Rs.4050/- 3.7kW
Rs.4150/-3.7kW to7.5kW
Rs.5000/-7.5kW to11kW
Rs.6100/-11kW to15kW |
| 12(Performance Value) |
- |
0 |
|
Rs.4050/- 3.7kW
Rs.4150/-3.7kW to7.5kW
Rs.5000/-7.5kW to11kW
Rs.6100/-11kW to15kW |
| 13(Overload) |
- |
0 |
|
Rs.4050/- 3.7kW
Rs.4150/-3.7kW to7.5kW
Rs.5000/-7.5kW to11kW
Rs.6100/-11kW to15kW |
| 14(Limits of temperature and temperature rise) |
- |
0 |
|
Rs.4050/- 3.7kW
Rs.4150/-3.7kW to7.5kW
Rs.5000/-7.5kW to11kW
Rs.6100/-11kW to15kW |
| 15(Limits of vibation severity) |
- |
0 |
|
Rs.4050/- 3.7kW
Rs.4150/-3.7kW to7.5kW
Rs.5000/-7.5kW to11kW
Rs.6100/-11kW to15kW |
| 16(Limits of noise Levels) |
- |
0 |
|
Rs.4050/- 3.7kW
Rs.4150/-3.7kW to7.5kW
Rs.5000/-7.5kW to11kW
Rs.6100/-11kW to15kW |
| 17(Efficiency and power factor) |
- |
0 |
|
Rs.4050/- 3.7kW
Rs.4150/-3.7kW to7.5kW
Rs.5000/-7.5kW to11kW
Rs.6100/-11kW to15kW |
| 18(Tolerance) |
- |
0 |
|
Rs.4050/- 3.7kW
Rs.4150/-3.7kW to7.5kW
Rs.5000/-7.5kW to11kW
Rs.6100/-11kW to15kW |
| 19(Terminal Box and Terminal Markings) |
- |
0 |
|
Rs.4050/- 3.7kW
Rs.4150/-3.7kW to7.5kW
Rs.5000/-7.5kW to11kW
Rs.6100/-11kW to15kW |
| 20(Marking) |
- |
0 |
|
Rs.4050/- 3.7kW
Rs.4150/-3.7kW to7.5kW
Rs.5000/-7.5kW to11kW
Rs.6100/-11kW to15kW |
| 21(Information to be given at the stage of enquary
and placing order for supply) |
- |
0 |
|
Rs.4050/- 3.7kW
Rs.4150/-3.7kW to7.5kW
Rs.5000/-7.5kW to11kW
Rs.6100/-11kW to15kW |
| 22(Test) |
- |
0 |
|
Rs.4050/- 3.7kW
Rs.4150/-3.7kW to7.5kW
Rs.5000/-7.5kW to11kW
Rs.6100/-11kW to15kW |
| 23(Temperature-Rise Test) |
- |
0 |
|
Rs.4050/- 3.7kW
Rs.4150/-3.7kW to7.5kW
Rs.5000/-7.5kW to11kW
Rs.6100/-11kW to15kW |
| 24(Performance Test) |
- |
0 |
|
Rs.4050/- 3.7kW
Rs.4150/-3.7kW to7.5kW
Rs.5000/-7.5kW to11kW
Rs.6100/-11kW to15kW |
| 25(High Voltage Test) |
- |
0 |
|
Rs.4050/- 3.7kW
Rs.4150/-3.7kW to7.5kW
Rs.5000/-7.5kW to11kW
Rs.6100/-11kW to15kW |
| 26(Insulation-Resistance Test) |
- |
0 |
|
Rs.4050/- 3.7kW
Rs.4150/-3.7kW to7.5kW
Rs.5000/-7.5kW to11kW
Rs.6100/-11kW to15kW |
| 27(Overspeed Test) |
- |
0 |
|
Rs.4050/- 3.7kW
Rs.4150/-3.7kW to7.5kW
Rs.5000/-7.5kW to11kW
Rs.6100/-11kW to15kW |
| 5(ENCLOSURES) |
- |
10000 |
|
Rs.4050/- 3.7kW
Rs.4150/-3.7kW to7.5kW
Rs.5000/-7.5kW to11kW
Rs.6100/-11kW to15kW |
| 6(COOLING) |
- |
0 |
|
Rs.4050/- 3.7kW
Rs.4150/-3.7kW to7.5kW
Rs.5000/-7.5kW to11kW
Rs.6100/-11kW to15kW |
| 7(MATERIALS) |
- |
0 |
|
Rs.4050/- 3.7kW
Rs.4150/-3.7kW to7.5kW
Rs.5000/-7.5kW to11kW
Rs.6100/-11kW to15kW |
| 8.1(Rated Voltage) |
- |
0 |
|
Rs.4050/- 3.7kW
Rs.4150/-3.7kW to7.5kW
Rs.5000/-7.5kW to11kW
Rs.6100/-11kW to15kW |
| 8.2(Rated Frequency) |
- |
0 |
|
Rs.4050/- 3.7kW
Rs.4150/-3.7kW to7.5kW
Rs.5000/-7.5kW to11kW
Rs.6100/-11kW to15kW |
| 8.3(Rated Outputs) |
- |
0 |
|
Rs.4050/- 3.7kW
Rs.4150/-3.7kW to7.5kW
Rs.5000/-7.5kW to11kW
Rs.6100/-11kW to15kW |
| 9(DIMENSIONS- H : Nominal ) |
- |
0 |
|
Rs.4050/- 3.7kW
Rs.4150/-3.7kW to7.5kW
Rs.5000/-7.5kW to11kW
Rs.6100/-11kW to15kW |
| 9(DIMENSIONS- H : Deviation ) |
- |
0 |
|
Rs.4050/- 3.7kW
Rs.4150/-3.7kW to7.5kW
Rs.5000/-7.5kW to11kW
Rs.6100/-11kW to15kW |
| 9(DIMENSIONS- A) |
- |
0 |
|
Rs.4050/- 3.7kW
Rs.4150/-3.7kW to7.5kW
Rs.5000/-7.5kW to11kW
Rs.6100/-11kW to15kW |
| 9(DIMENSIONS- B) |
- |
0 |
|
Rs.4050/- 3.7kW
Rs.4150/-3.7kW to7.5kW
Rs.5000/-7.5kW to11kW
Rs.6100/-11kW to15kW |
| 9(DIMENSIONS- C) |
- |
0 |
|
Rs.4050/- 3.7kW
Rs.4150/-3.7kW to7.5kW
Rs.5000/-7.5kW to11kW
Rs.6100/-11kW to15kW |
| 9(DIMENSIONS- K+ : Nominal ) |
- |
0 |
|
Rs.4050/- 3.7kW
Rs.4150/-3.7kW to7.5kW
Rs.5000/-7.5kW to11kW
Rs.6100/-11kW to15kW |
| 9(DIMENSIONS- K+ : Tolerance ) |
- |
0 |
|
Rs.4050/- 3.7kW
Rs.4150/-3.7kW to7.5kW
Rs.5000/-7.5kW to11kW
Rs.6100/-11kW to15kW |
| 9(DIMENSIONS- Bolt or Screw) |
- |
0 |
|
Rs.4050/- 3.7kW
Rs.4150/-3.7kW to7.5kW
Rs.5000/-7.5kW to11kW
Rs.6100/-11kW to15kW |
| 9(DIMENSIONS- M) |
- |
0 |
|
Rs.4050/- 3.7kW
Rs.4150/-3.7kW to7.5kW
Rs.5000/-7.5kW to11kW
Rs.6100/-11kW to15kW |
| 9(DIMENSIONS- N) |
- |
0 |
|
Rs.4050/- 3.7kW
Rs.4150/-3.7kW to7.5kW
Rs.5000/-7.5kW to11kW
Rs.6100/-11kW to15kW |
| 9(DIMENSIONS- P) |
- |
0 |
|
Rs.4050/- 3.7kW
Rs.4150/-3.7kW to7.5kW
Rs.5000/-7.5kW to11kW
Rs.6100/-11kW to15kW |
| 9(DIMENSIONS- S) |
- |
0 |
|
Rs.4050/- 3.7kW
Rs.4150/-3.7kW to7.5kW
Rs.5000/-7.5kW to11kW
Rs.6100/-11kW to15kW |
| 9(DIMENSIONS- T) |
- |
0 |
|
Rs.4050/- 3.7kW
Rs.4150/-3.7kW to7.5kW
Rs.5000/-7.5kW to11kW
Rs.6100/-11kW to15kW |
| 9(DIMENSIONS- LA) |
- |
0 |
|
Rs.4050/- 3.7kW
Rs.4150/-3.7kW to7.5kW
Rs.5000/-7.5kW to11kW
Rs.6100/-11kW to15kW |
| 9(DIMENSIONS- Depth of tapped Hole) |
- |
0 |
|
Rs.4050/- 3.7kW
Rs.4150/-3.7kW to7.5kW
Rs.5000/-7.5kW to11kW
Rs.6100/-11kW to15kW |
| 10(TYPE OF DUTY AND CLASSES OF
RATING) |
- |
0 |
|
Rs.4050/- 3.7kW
Rs.4150/-3.7kW to7.5kW
Rs.5000/-7.5kW to11kW
Rs.6100/-11kW to15kW |
| 11(PROVISION FOR EARTHING) |
- |
0 |
|
Rs.4050/- 3.7kW
Rs.4150/-3.7kW to7.5kW
Rs.5000/-7.5kW to11kW
Rs.6100/-11kW to15kW |
| 12.1, Table 1 to Table 6(Minimum full load speed) |
- |
0 |
|
Rs.4050/- 3.7kW
Rs.4150/-3.7kW to7.5kW
Rs.5000/-7.5kW to11kW
Rs.6100/-11kW to15kW |
| 12.1, Table 1 to Table 6(maximum full load
current) |
- |
0 |
|
Rs.4050/- 3.7kW
Rs.4150/-3.7kW to7.5kW
Rs.5000/-7.5kW to11kW
Rs.6100/-11kW to15kW |
| 12.1, Table 1 to Table 6(minimum starting torque/ breakaway torque ) |
- |
0 |
|
Rs.4050/- 3.7kW
Rs.4150/-3.7kW to7.5kW
Rs.5000/-7.5kW to11kW
Rs.6100/-11kW to15kW |
| 12.1, Table 1 to Table 6(nominal efficiency) |
- |
0 |
|
Rs.4050/- 3.7kW
Rs.4150/-3.7kW to7.5kW
Rs.5000/-7.5kW to11kW
Rs.6100/-11kW to15kW |
| 12.1, Table 1 to Table 6(nominal efficiency at 75% rated load) |
- |
0 |
|
Rs.4050/- 3.7kW
Rs.4150/-3.7kW to7.5kW
Rs.5000/-7.5kW to11kW
Rs.6100/-11kW to15kW |
| 13.1(OVERLOAD:Momentary Excess Torque) |
- |
0 |
|
Rs.4050/- 3.7kW
Rs.4150/-3.7kW to7.5kW
Rs.5000/-7.5kW to11kW
Rs.6100/-11kW to15kW |
| 13.2(OVERLOAD:Sustained Overloads) |
- |
0 |
|
Rs.4050/- 3.7kW
Rs.4150/-3.7kW to7.5kW
Rs.5000/-7.5kW to11kW
Rs.6100/-11kW to15kW |
| 14(LIMITS OF TEMPERATURES AND
TEMPERATURE-RISE) |
- |
0 |
|
Rs.4050/- 3.7kW
Rs.4150/-3.7kW to7.5kW
Rs.5000/-7.5kW to11kW
Rs.6100/-11kW to15kW |
| 15(LIMITS OF VIBRATION SEVERITY) |
- |
0 |
|
Rs.4050/- 3.7kW
Rs.4150/-3.7kW to7.5kW
Rs.5000/-7.5kW to11kW
Rs.6100/-11kW to15kW |
| 16(LIMITS OF NOISE LEVELS) |
- |
0 |
|
Rs.4050/- 3.7kW
Rs.4150/-3.7kW to7.5kW
Rs.5000/-7.5kW to11kW
Rs.6100/-11kW to15kW |
| 17.1(Efficiency) |
- |
0 |
|
Rs.4050/- 3.7kW
Rs.4150/-3.7kW to7.5kW
Rs.5000/-7.5kW to11kW
Rs.6100/-11kW to15kW |
| 17.2(Power Factor) |
- |
0 |
|
Rs.4050/- 3.7kW
Rs.4150/-3.7kW to7.5kW
Rs.5000/-7.5kW to11kW
Rs.6100/-11kW to15kW |
| 18(TOLERANCES) |
- |
0 |
|
Rs.4050/- 3.7kW
Rs.4150/-3.7kW to7.5kW
Rs.5000/-7.5kW to11kW
Rs.6100/-11kW to15kW |
| 19.1(TERMINAL BOX) |
- |
0 |
|
Rs.4050/- 3.7kW
Rs.4150/-3.7kW to7.5kW
Rs.5000/-7.5kW to11kW
Rs.6100/-11kW to15kW |
| 19.1.1(TERMINAL
MARKINGS) |
- |
0 |
|
Rs.4050/- 3.7kW
Rs.4150/-3.7kW to7.5kW
Rs.5000/-7.5kW to11kW
Rs.6100/-11kW to15kW |
| 20.1( MARKING) |
- |
0 |
|
Rs.4050/- 3.7kW
Rs.4150/-3.7kW to7.5kW
Rs.5000/-7.5kW to11kW
Rs.6100/-11kW to15kW |
| 20.2(BIS Certification Marking) |
- |
0 |
|
Rs.4050/- 3.7kW
Rs.4150/-3.7kW to7.5kW
Rs.5000/-7.5kW to11kW
Rs.6100/-11kW to15kW |
| 22.3.1 b)(Measurement of stator resistance) |
- |
0 |
|
Rs.4050/- 3.7kW
Rs.4150/-3.7kW to7.5kW
Rs.5000/-7.5kW to11kW
Rs.6100/-11kW to15kW |
| 23.1(TEMPERATURE-RISE TEST : Test at Rated Voltage) |
- |
0 |
|
Rs.4050/- 3.7kW
Rs.4150/-3.7kW to7.5kW
Rs.5000/-7.5kW to11kW
Rs.6100/-11kW to15kW |
| 23.2(TEMPERATURE-RISE TEST: Test at Reduced Voltage) |
- |
0 |
|
Rs.4050/- 3.7kW
Rs.4150/-3.7kW to7.5kW
Rs.5000/-7.5kW to11kW
Rs.6100/-11kW to15kW |
| 24.1(No-load running of motor and reading of
' voltage) |
- |
0 |
|
Rs.4050/- 3.7kW
Rs.4150/-3.7kW to7.5kW
Rs.5000/-7.5kW to11kW
Rs.6100/-11kW to15kW |
| 24.1(No-load running of motor and reading of
' current ) |
- |
0 |
|
Rs.4050/- 3.7kW
Rs.4150/-3.7kW to7.5kW
Rs.5000/-7.5kW to11kW
Rs.6100/-11kW to15kW |
| 24.1(No-load running of motor and reading of
' power input ) |
- |
0 |
|
Rs.4050/- 3.7kW
Rs.4150/-3.7kW to7.5kW
Rs.5000/-7.5kW to11kW
Rs.6100/-11kW to15kW |
| 24.1(No-load running of motor and reading of
' speed ) |
- |
0 |
|
Rs.4050/- 3.7kW
Rs.4150/-3.7kW to7.5kW
Rs.5000/-7.5kW to11kW
Rs.6100/-11kW to15kW |
| 24.2(Reduced Voltage Running Up Test) |
- |
0 |
|
Rs.4050/- 3.7kW
Rs.4150/-3.7kW to7.5kW
Rs.5000/-7.5kW to11kW
Rs.6100/-11kW to15kW |
| 24.3(Locked Rotor Test:The readings of the input
current) |
- |
0 |
|
Rs.4050/- 3.7kW
Rs.4150/-3.7kW to7.5kW
Rs.5000/-7.5kW to11kW
Rs.6100/-11kW to15kW |
| 24.3(Locked Rotor Test:The readings of the input
power) |
- |
0 |
|
Rs.4050/- 3.7kW
Rs.4150/-3.7kW to7.5kW
Rs.5000/-7.5kW to11kW
Rs.6100/-11kW to15kW |
| 24.3(Locked Rotor Test:The readings of the breakaway rotor torque) |
- |
0 |
|
Rs.4050/- 3.7kW
Rs.4150/-3.7kW to7.5kW
Rs.5000/-7.5kW to11kW
Rs.6100/-11kW to15kW |
| 24.4(Full Load Test : voltage) |
- |
0 |
|
Rs.4050/- 3.7kW
Rs.4150/-3.7kW to7.5kW
Rs.5000/-7.5kW to11kW
Rs.6100/-11kW to15kW |
| 24.4(Full Load Test : Power input ) |
- |
0 |
|
Rs.4050/- 3.7kW
Rs.4150/-3.7kW to7.5kW
Rs.5000/-7.5kW to11kW
Rs.6100/-11kW to15kW |
| 24.4(Full Load Test : current ) |
- |
0 |
|
Rs.4050/- 3.7kW
Rs.4150/-3.7kW to7.5kW
Rs.5000/-7.5kW to11kW
Rs.6100/-11kW to15kW |
| 24.4(Full Load Test : speed) |
- |
0 |
|
Rs.4050/- 3.7kW
Rs.4150/-3.7kW to7.5kW
Rs.5000/-7.5kW to11kW
Rs.6100/-11kW to15kW |
| 24.5(Test for efficiency at reduced load) |
- |
0 |
|
Rs.4050/- 3.7kW
Rs.4150/-3.7kW to7.5kW
Rs.5000/-7.5kW to11kW
Rs.6100/-11kW to15kW |
| 25(HIGH-VOLTAGE TEST) |
- |
0 |
|
Rs.4050/- 3.7kW
Rs.4150/-3.7kW to7.5kW
Rs.5000/-7.5kW to11kW
Rs.6100/-11kW to15kW |
| 26(INSULATION-RESISTANCE TEST) |
- |
0 |
|
Rs.4050/- 3.7kW
Rs.4150/-3.7kW to7.5kW
Rs.5000/-7.5kW to11kW
Rs.6100/-11kW to15kW |
| 27(OVERSPEED TEST) |
- |
0 |
|
Rs.4050/- 3.7kW
Rs.4150/-3.7kW to7.5kW
Rs.5000/-7.5kW to11kW
Rs.6100/-11kW to15kW |
| Site Conditions(Tested as per 4 of IS 325: 1996) |
- |
0 |
|
Rs.4050/- 3.7kW
Rs.4150/-3.7kW to7.5kW
Rs.5000/-7.5kW to11kW
Rs.6100/-11kW to15kW |
| 5(Enclosure) |
- |
0 |
|
Rs.4050/- 3.7kW
Rs.4150/-3.7kW to7.5kW
Rs.5000/-7.5kW to11kW
Rs.6100/-11kW to15kW |
| 6(Cooling) |
- |
0 |
|
Rs.4050/- 3.7kW
Rs.4150/-3.7kW to7.5kW
Rs.5000/-7.5kW to11kW
Rs.6100/-11kW to15kW |
| 7(Materials) |
- |
0 |
|
Rs.4050/- 3.7kW
Rs.4150/-3.7kW to7.5kW
Rs.5000/-7.5kW to11kW
Rs.6100/-11kW to15kW |
| 8("Rated conditions of voltage, frequenecy and
output of motor ") |
- |
0 |
|
Rs.4050/- 3.7kW
Rs.4150/-3.7kW to7.5kW
Rs.5000/-7.5kW to11kW
Rs.6100/-11kW to15kW |
| 9(Dimensions) |
- |
0 |
|
Rs.4050/- 3.7kW
Rs.4150/-3.7kW to7.5kW
Rs.5000/-7.5kW to11kW
Rs.6100/-11kW to15kW |
| 10(Types of duty and classes of rating) |
- |
0 |
|
Rs.4050/- 3.7kW
Rs.4150/-3.7kW to7.5kW
Rs.5000/-7.5kW to11kW
Rs.6100/-11kW to15kW |
| 11(Provision for earthing) |
- |
0 |
|
Rs.4050/- 3.7kW
Rs.4150/-3.7kW to7.5kW
Rs.5000/-7.5kW to11kW
Rs.6100/-11kW to15kW |
| 12(Performance Value) |
- |
0 |
|
Rs.4050/- 3.7kW
Rs.4150/-3.7kW to7.5kW
Rs.5000/-7.5kW to11kW
Rs.6100/-11kW to15kW |
| 13(Overload) |
- |
0 |
|
Rs.4050/- 3.7kW
Rs.4150/-3.7kW to7.5kW
Rs.5000/-7.5kW to11kW
Rs.6100/-11kW to15kW |
| 14(Limits of temperature and temperature rise) |
- |
0 |
|
Rs.4050/- 3.7kW
Rs.4150/-3.7kW to7.5kW
Rs.5000/-7.5kW to11kW
Rs.6100/-11kW to15kW |
| 15(Limits of vibation severity) |
- |
0 |
|
Rs.4050/- 3.7kW
Rs.4150/-3.7kW to7.5kW
Rs.5000/-7.5kW to11kW
Rs.6100/-11kW to15kW |
| 16(Limits of noise Levels) |
- |
0 |
|
Rs.4050/- 3.7kW
Rs.4150/-3.7kW to7.5kW
Rs.5000/-7.5kW to11kW
Rs.6100/-11kW to15kW |
| 17(Efficiency and power factor) |
- |
0 |
|
Rs.4050/- 3.7kW
Rs.4150/-3.7kW to7.5kW
Rs.5000/-7.5kW to11kW
Rs.6100/-11kW to15kW |
| 18(Tolerance) |
- |
0 |
|
Rs.4050/- 3.7kW
Rs.4150/-3.7kW to7.5kW
Rs.5000/-7.5kW to11kW
Rs.6100/-11kW to15kW |
| 19(Terminal Box and Terminal Markings) |
- |
0 |
|
Rs.4050/- 3.7kW
Rs.4150/-3.7kW to7.5kW
Rs.5000/-7.5kW to11kW
Rs.6100/-11kW to15kW |
| 20(Marking) |
- |
0 |
|
Rs.4050/- 3.7kW
Rs.4150/-3.7kW to7.5kW
Rs.5000/-7.5kW to11kW
Rs.6100/-11kW to15kW |
| 21(Information to be given at the stage of enquary
and placing order for supply) |
- |
0 |
|
Rs.4050/- 3.7kW
Rs.4150/-3.7kW to7.5kW
Rs.5000/-7.5kW to11kW
Rs.6100/-11kW to15kW |
| 22(Test) |
- |
0 |
|
Rs.4050/- 3.7kW
Rs.4150/-3.7kW to7.5kW
Rs.5000/-7.5kW to11kW
Rs.6100/-11kW to15kW |
| 23(Temperature-Rise Test) |
- |
0 |
|
Rs.4050/- 3.7kW
Rs.4150/-3.7kW to7.5kW
Rs.5000/-7.5kW to11kW
Rs.6100/-11kW to15kW |
| 24(Performance Test) |
- |
0 |
|
Rs.4050/- 3.7kW
Rs.4150/-3.7kW to7.5kW
Rs.5000/-7.5kW to11kW
Rs.6100/-11kW to15kW |
| 25(High Voltage Test) |
- |
0 |
|
Rs.4050/- 3.7kW
Rs.4150/-3.7kW to7.5kW
Rs.5000/-7.5kW to11kW
Rs.6100/-11kW to15kW |
| 26(Insulation-Resistance Test) |
- |
0 |
|
Rs.4050/- 3.7kW
Rs.4150/-3.7kW to7.5kW
Rs.5000/-7.5kW to11kW
Rs.6100/-11kW to15kW |
| 27(Overspeed Test) |
- |
0 |
|
Rs.4050/- 3.7kW
Rs.4150/-3.7kW to7.5kW
Rs.5000/-7.5kW to11kW
Rs.6100/-11kW to15kW |
|
28 Oct, 2028 |
- included w.e.f 01.04.2026 |
| 7 |
IS 12225 (2025) |
CENTRIFUGAL JET PUMP SPECIFICATION (second revision) |
- |
6200 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl-6.1(Other General Requirements) |
- |
0 |
|
Rs.6200/- for single phase up to 2.2 kW |
| Cl-6.2(Hydrostatic Test) |
- |
0 |
|
Rs.6200/- for single phase up to 2.2 kW |
| Cl-6.3(Cables used) |
- |
0 |
|
Rs.6200/- for single phase up to 2.2 kW |
| Cl-6.4(Voltage and Frequency Variation) |
- |
0 |
|
Rs.6200/- for single phase up to 2.2 kW |
| Cl-8(Centrifugal jet pump) |
- |
0 |
|
Rs.6200/- for single phase up to 2.2 kW |
| Cl-9.1(Factor Affecting Performance) |
- |
0 |
|
Rs.6200/- for single phase up to 2.2 kW |
| Cl-9.2(Performance Curves) |
- |
0 |
|
Rs.6200/- for single phase up to 2.2 kW |
| Cl-10.1(Method of Testing) |
- |
0 |
|
Rs.6200/- for single phase up to 2.2 kW |
| Cl-10.2(Testing Method for Centrifugal Jet Pump for Including Pipe Friction by the Use of Orifice Plate) |
- |
0 |
|
Rs.6200/- for single phase up to 2.2 kW |
| Cl-11(TOLERANCES) |
- |
0 |
|
Rs.6200/- for single phase up to 2.2 kW |
| Cl-13(Marking) |
- |
0 |
|
Rs.6200/- for single phase up to 2.2 kW |
| Cl-6.1(Other General Requirements) |
- |
- |
|
- |
| Cl-6.2(Hydrostatic Test) |
- |
- |
|
- |
| Cl-6.3(Cables used) |
- |
- |
|
- |
| Cl-6.4(Voltage and Frequency Variation) |
- |
- |
|
- |
| Cl-8(Centrifugal jet pump) |
- |
- |
|
- |
| Cl-9.1(Factor Affecting Performance) |
- |
- |
|
- |
| Cl-9.2(Performance Curves) |
- |
- |
|
- |
| Cl-10.1(Method of Testing) |
- |
- |
|
- |
| Cl-10.2(Testing Method for Centrifugal Jet Pump for Including Pipe Friction by the Use of Orifice Plate) |
- |
- |
|
- |
| Cl-11(TOLERANCES) |
- |
- |
|
- |
| Cl-13(Marking) |
- |
- |
|
- |
| Cl-5.1(Centrifugal Pumps) |
- |
- |
|
- |
| Cl-5.2.1(Motor Drive) |
- |
- |
|
- |
| Cl-5.2.3(Coupled and Belt Driven Set) |
- |
- |
|
- |
|
28 Oct, 2028 |
- 1.
Cl-6.3 (Cables used) Cable used shall be as per IS 694 Laboratory does not have complete test facility as per IS 694.
2.
Cl-5.2.2 (Engine Drive) Prime movers - Engine drives Laboratory does not have complete test facility as per IS 7347 or IS 10001 or IS 11170.
3.
Cl-7 (Material of Construction) Material of construction Laboratory does not have complete test facility" |
| 8 |
IS 779 (1994) |
Water meters (Domestic Type) - Specification (Sixth Revision) |
- |
27400 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 13(Marking) |
- |
0 |
|
Rs.27400/- |
| 4(Nominal Size) |
- |
0 |
|
Rs.27400/- |
| 5(Classes of Water meter) |
- |
0 |
|
Rs.27400/- |
| 7(Construction) |
- |
0 |
|
Rs.27400/- |
| 7.2(i) Body) |
- |
0 |
|
Rs.27400/- |
| 7.3(Registration Box) |
- |
0 |
|
Rs.27400/- |
| 7.4(Cap) |
- |
0 |
|
Rs.27400/- |
| 7.5(Connections ) |
- |
0 |
|
Rs.27400/- |
| 7.6(Strainers) |
- |
0 |
|
Rs.27400/- |
| 7.7(Impeller and pistons) |
- |
0 |
|
Rs.27400/- |
| 7.8(Impeller, Chamber and Measuring Chamber ) |
- |
0 |
|
Rs.27400/- |
| 7.9(Gears & Pinions ) |
- |
0 |
|
Rs.27400/- |
| 7.1(Bearings) |
- |
0 |
|
Rs.27400/- |
| 7.11(Counter) |
- |
0 |
|
Rs.27400/- |
| 7.12(Dial) |
- |
0 |
|
Rs.27400/- |
| 7.13(Regulator) |
- |
0 |
|
Rs.27400/- |
| 7.14(Sealing) |
- |
0 |
|
Rs.27400/- |
| 7.15(Frost protection device) |
- |
0 |
|
Rs.27400/- |
| 8.1 & 8.2(Indicating device) |
- |
0 |
|
Rs.27400/- |
| 8.3(Value of verification Scale division ) |
- |
0 |
|
Rs.27400/- |
| 8.4(Acceleration Device) |
- |
0 |
|
Rs.27400/- |
| 9.1, table 2(i)Threads ) |
- |
0 |
|
Rs.27400/- |
| 9.1, table 3(ii)Thread Length ‘a’ ) |
- |
0 |
|
Rs.27400/- |
| 9.1, table 4( ‘b’ ) |
- |
0 |
|
Rs.27400/- |
| 9.1, table 5(iii) Overall Length (with nipple)) |
- |
0 |
|
Rs.27400/- |
| 9.1, table 6(iv)Overall Width ) |
- |
0 |
|
Rs.27400/- |
| 9.1, table 7(v)Overall Height H1) |
- |
0 |
|
Rs.27400/- |
| 9.1, table 8( H2 ) |
- |
0 |
|
Rs.27400/- |
| 10.1(Pressure tightness) |
- |
0 |
|
Rs.27400/- |
| 10.2(Loss of pressure) |
- |
0 |
|
Rs.27400/- |
| 11.1(Metering Accuracy) |
- |
0 |
|
Rs.27400/- |
| 11.2(Min. Starting flow) |
- |
0 |
|
Rs.27400/- |
| 10.3(Temp. suitability ) |
- |
0 |
|
Rs.27400/- |
| 10.1(Pressure tightness) |
- |
0 |
|
Rs.27400/- |
| 10.2(Loss of pressure) |
- |
0 |
|
Rs.27400/- |
| 11.1(Metering Accuracy) |
- |
0 |
|
Rs.27400/- |
| 12.4.3(Construction) |
- |
0 |
|
Rs.27400/- |
| 12.4.4(Life test ) |
- |
0 |
|
Rs.27400/- |
| 10.1(Pressure tightness) |
- |
0 |
|
Rs.27400/- |
| 10.2(Loss of pressure) |
- |
0 |
|
Rs.27400/- |
| 11.1(Metering Accuracy) |
- |
0 |
|
Rs.27400/- |
| 11.2(Min. Starting flow) |
- |
0 |
|
Rs.27400/- |
| 10.3(Temp. suitability ) |
- |
0 |
|
Rs.27400/- |
| 10.1(Pressure tightness) |
- |
0 |
|
Rs.27400/- |
| 10.2(Loss of pressure) |
- |
0 |
|
Rs.27400/- |
| 11.1(Metering Accuracy) |
- |
0 |
|
Rs.27400/- |
| 12.4.2(Construction) |
- |
0 |
|
Rs.27400/- |
| 13(Marking) |
- |
0 |
|
Rs.27400/- |
| 4(Nominal Size) |
- |
0 |
|
Rs.27400/- |
| 5(Classes of Water meter) |
- |
0 |
|
Rs.27400/- |
| 7(Construction) |
- |
0 |
|
Rs.27400/- |
| 7.2(i) Body) |
- |
0 |
|
Rs.27400/- |
| 7.3(Registration Box) |
- |
0 |
|
Rs.27400/- |
| 7.4(Cap) |
- |
0 |
|
Rs.27400/- |
| 7.5(Connections ) |
- |
0 |
|
Rs.27400/- |
| 7.6(Strainers) |
- |
0 |
|
Rs.27400/- |
| 7.7(Impeller and pistons) |
- |
0 |
|
Rs.27400/- |
| 7.8(Impeller, Chamber and Measuring Chamber ) |
- |
0 |
|
Rs.27400/- |
| 7.9(Gears & Pinions ) |
- |
0 |
|
Rs.27400/- |
| 7.1(Bearings) |
- |
0 |
|
Rs.27400/- |
| 7.11(Counter) |
- |
0 |
|
Rs.27400/- |
| 7.12(Dial) |
- |
0 |
|
Rs.27400/- |
| 7.13(Regulator) |
- |
0 |
|
Rs.27400/- |
| 7.14(Sealing) |
- |
0 |
|
Rs.27400/- |
| 7.15(Frost protection device) |
- |
0 |
|
Rs.27400/- |
| 8.1 & 8.2(Indicating device) |
- |
0 |
|
Rs.27400/- |
| 8.3(Value of verification Scale division ) |
- |
0 |
|
Rs.27400/- |
| 8.4(Acceleration Device) |
- |
0 |
|
Rs.27400/- |
| 9.1, table 2(i)Threads ) |
- |
0 |
|
Rs.27400/- |
| 9.1, table 3(ii)Thread Length ‘a’ ) |
- |
0 |
|
Rs.27400/- |
| 9.1, table 4( ‘b’ ) |
- |
0 |
|
Rs.27400/- |
| 9.1, table 5(iii) Overall Length (with nipple)) |
- |
0 |
|
Rs.27400/- |
| 9.1, table 6(iv)Overall Width ) |
- |
0 |
|
Rs.27400/- |
| 9.1, table 7(v)Overall Height H1) |
- |
0 |
|
Rs.27400/- |
| 9.1, table 8( H2 ) |
- |
0 |
|
Rs.27400/- |
| 10.1(Pressure tightness) |
- |
0 |
|
Rs.27400/- |
| 10.2(Loss of pressure) |
- |
0 |
|
Rs.27400/- |
| 11.1(Metering Accuracy) |
- |
0 |
|
Rs.27400/- |
| 11.2(Min. Starting flow) |
- |
0 |
|
Rs.27400/- |
| 10.3(Temp. suitability ) |
- |
0 |
|
Rs.27400/- |
| 10.1(Pressure tightness) |
- |
0 |
|
Rs.27400/- |
| 10.2(Loss of pressure) |
- |
0 |
|
Rs.27400/- |
| 11.1(Metering Accuracy) |
- |
0 |
|
Rs.27400/- |
| 12.4.3(Construction) |
- |
0 |
|
Rs.27400/- |
| 12.4.4(Life test ) |
- |
0 |
|
Rs.27400/- |
| 10.1(Pressure tightness) |
- |
0 |
|
Rs.27400/- |
| 10.2(Loss of pressure) |
- |
0 |
|
Rs.27400/- |
| 11.1(Metering Accuracy) |
- |
0 |
|
Rs.27400/- |
| 11.2(Min. Starting flow) |
- |
0 |
|
Rs.27400/- |
| 10.3(Temp. suitability ) |
- |
0 |
|
Rs.27400/- |
| 10.1(Pressure tightness) |
- |
0 |
|
Rs.27400/- |
| 10.2(Loss of pressure) |
- |
0 |
|
Rs.27400/- |
| 11.1(Metering Accuracy) |
- |
0 |
|
Rs.27400/- |
| 12.4.2(Construction) |
- |
0 |
|
Rs.27400/- |
| 13(Marking) |
- |
0 |
|
Rs.27400/- |
| 4(Nominal Size) |
- |
0 |
|
Rs.27400/- |
| 5(Classes of Water meter) |
- |
0 |
|
Rs.27400/- |
| 7(Construction) |
- |
0 |
|
Rs.27400/- |
| 7.2(i) Body) |
- |
0 |
|
Rs.27400/- |
| 7.3(Registration Box) |
- |
0 |
|
Rs.27400/- |
| 7.4(Cap) |
- |
0 |
|
Rs.27400/- |
| 7.5(Connections ) |
- |
0 |
|
Rs.27400/- |
| 7.6(Strainers) |
- |
0 |
|
Rs.27400/- |
| 7.7(Impeller and pistons) |
- |
0 |
|
Rs.27400/- |
| 7.8(Impeller, Chamber and Measuring Chamber ) |
- |
0 |
|
Rs.27400/- |
| 7.9(Gears & Pinions ) |
- |
0 |
|
Rs.27400/- |
| 7.1(Bearings) |
- |
0 |
|
Rs.27400/- |
| 7.11(Counter) |
- |
0 |
|
Rs.27400/- |
| 7.12(Dial) |
- |
0 |
|
Rs.27400/- |
| 7.13(Regulator) |
- |
0 |
|
Rs.27400/- |
| 7.14(Sealing) |
- |
0 |
|
Rs.27400/- |
| 7.15(Frost protection device) |
- |
0 |
|
Rs.27400/- |
| 8.1 & 8.2(Indicating device) |
- |
0 |
|
Rs.27400/- |
| 8.3(Value of verification Scale division ) |
- |
0 |
|
Rs.27400/- |
| 8.4(Acceleration Device) |
- |
0 |
|
Rs.27400/- |
| 9.1, table 2(i)Threads ) |
- |
0 |
|
Rs.27400/- |
| 9.1, table 3(ii)Thread Length ‘a’ ) |
- |
0 |
|
Rs.27400/- |
| 9.1, table 4( ‘b’ ) |
- |
0 |
|
Rs.27400/- |
| 9.1, table 5(iii) Overall Length (with nipple)) |
- |
0 |
|
Rs.27400/- |
| 9.1, table 6(iv)Overall Width ) |
- |
0 |
|
Rs.27400/- |
| 9.1, table 7(v)Overall Height H1) |
- |
0 |
|
Rs.27400/- |
| 9.1, table 8( H2 ) |
- |
0 |
|
Rs.27400/- |
| 10.1(Pressure tightness) |
- |
0 |
|
Rs.27400/- |
| 10.2(Loss of pressure) |
- |
0 |
|
Rs.27400/- |
| 11.1(Metering Accuracy) |
- |
0 |
|
Rs.27400/- |
| 11.2(Min. Starting flow) |
- |
0 |
|
Rs.27400/- |
| 10.3(Temp. suitability ) |
- |
0 |
|
Rs.27400/- |
| 10.1(Pressure tightness) |
- |
0 |
|
Rs.27400/- |
| 10.2(Loss of pressure) |
- |
0 |
|
Rs.27400/- |
| 11.1(Metering Accuracy) |
- |
0 |
|
Rs.27400/- |
| 12.4.3(Construction) |
- |
0 |
|
Rs.27400/- |
| 12.4.4(Life test ) |
- |
0 |
|
Rs.27400/- |
| 10.1(Pressure tightness) |
- |
0 |
|
Rs.27400/- |
| 10.2(Loss of pressure) |
- |
0 |
|
Rs.27400/- |
| 11.1(Metering Accuracy) |
- |
0 |
|
Rs.27400/- |
| 11.2(Min. Starting flow) |
- |
0 |
|
Rs.27400/- |
| 10.3(Temp. suitability ) |
- |
0 |
|
Rs.27400/- |
| 10.1(Pressure tightness) |
- |
0 |
|
Rs.27400/- |
| 10.2(Loss of pressure) |
- |
0 |
|
Rs.27400/- |
| 11.1(Metering Accuracy) |
- |
0 |
|
Rs.27400/- |
| 12.4.2(Construction) |
- |
0 |
|
Rs.27400/- |
| Cl-6.1.1 (b)(Elongation) |
- |
0 |
|
Rs.27400/- |
| Cl-6.1.1 (c)(Water absorption on immersion) |
- |
0 |
|
Rs.27400/- |
| Cl-6.1.1 (d)(withstanding temperature) |
- |
0 |
|
Rs.27400/- |
|
28 Oct, 2028 |
- - |
| 9 |
IS 8472 (2019) |
Centrifugal regenerative pumps for clear, cold water - Specification (Second Revision) |
- |
6200 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 16.1(Marking) |
- |
0 |
|
Rs.6200/- |
| 16.1(Marking) |
- |
0 |
|
Rs.6200/- |
| 16.1(Marking) |
- |
0 |
|
Rs.6200/- |
| 16.1(Marking) |
- |
0 |
|
Rs.6200/- |
| 16.1(Marking) |
- |
0 |
|
Rs.6200/- |
| 16.1(Marking) |
- |
0 |
|
Rs.6200/- |
| 16.1(Marking) |
- |
0 |
|
Rs.6200/- |
| 16.1(Marking) |
- |
0 |
|
Rs.6200/- |
| 16.1(Marking) |
- |
0 |
|
Rs.6200/- |
| 16.1(Marking) |
- |
0 |
|
Rs.6200/- |
| 16.1(Marking) |
- |
0 |
|
Rs.6200/- |
| 16.1(Marking) |
- |
0 |
|
Rs.6200/- |
| 16.1(Marking) |
- |
0 |
|
Rs.6200/- |
| 16.1(Marking) |
- |
0 |
|
Rs.6200/- |
| 16.1(Marking) |
- |
0 |
|
Rs.6200/- |
| 16.1(Marking) |
- |
0 |
|
Rs.6200/- |
| 16.1(Marking) |
- |
0 |
|
Rs.6200/- |
| 16.1(Marking) |
- |
0 |
|
Rs.6200/- |
| 16.1(Marking) |
- |
0 |
|
Rs.6200/- |
| 16.1(Marking) |
- |
0 |
|
Rs.6200/- |
| 16.1(Marking) |
- |
0 |
|
Rs.6200/- |
| 12.1(Pump Tests
Cl.8 of IS 11346-2002
Rate of flow and head
Cl.8 of IS 11346-2002) |
- |
0 |
|
Rs.6200/- |
| 12.1(Pump Tests
Cl.8 of IS 11346-2002
Rate of flow and head
Cl.8 of IS 11346-2002) |
- |
0 |
|
Rs.6200/- |
| 12.1(Pump Tests
Cl.8 of IS 11346-2002
Efficiency
Cl.8.3 of IS 11346-2002) |
- |
0 |
|
Rs.6200/- |
| 12.3(Hydrostatic Pressure Test) |
- |
0 |
|
Rs.6200/- |
| 12.3.1(Hydrostatic Pressure Test) |
- |
0 |
|
Rs.6200/- |
| 12.4(Pump tests) |
- |
0 |
|
Rs.6200/- |
| 12.5(Self-Priming Test for Self-Priming Pumps) |
- |
0 |
|
Rs.6200/- |
| 13.1.2(No Load Test at Rated Voltage) |
- |
0 |
|
Rs.6200/- |
| 13.1.2.1.1(Temperature Rise Test at Rated Voltage) |
- |
0 |
|
Rs.6200/- |
| 13.1.2.1.2(Temperature Rise Test at Reduced Voltage) |
- |
0 |
|
Rs.6200/- |
| 15.1(Guarantee of Workmanship and Material) |
- |
0 |
|
Rs.6200/- |
| 13.1.2(Break away torque Pull up torque) |
- |
0 |
|
Rs.6200/- |
| 13.1.2(High Voltage test) |
- |
0 |
|
Rs.6200/- |
| 13.1.2(Insulation Resistance) |
- |
0 |
|
Rs.6200/- |
| 8(Direction of Rotation) |
- |
0 |
|
Rs.6200/- |
| 7(Material of Constructional) |
- |
0 |
|
Rs.6200/- |
| 11.1(General Requirements) |
- |
0 |
|
Rs.6200/- |
| 13.1.2(Measurement of stator resistance) |
- |
0 |
|
Rs.6200/- |
| 13.1(Single phase monoset pumps) |
- |
0 |
|
Rs.6200/- |
| 13.1.2(Locked rotor test(cl.6.2(d) of IS 14582)) |
- |
0 |
|
Rs.6200/- |
| 13(Tests for Electrical Performance) |
- |
0 |
|
Rs.6200/- |
| 7(Materials of Construction ( Casing/Chamber)) |
- |
0 |
|
Rs.6200/- |
| 7(Materials of Construction ( Impeller)) |
- |
0 |
|
Rs.6200/- |
| 7(Materials of Construction ( Shaft)) |
- |
0 |
|
Rs.6200/- |
| 8.1, 8.2(The direction of rotation of pumps) |
- |
0 |
|
Rs.6200/- |
| 8.3(The direction of inlet and outlet flow passages) |
- |
0 |
|
Rs.6200/- |
| 10.1(Design Features) |
- |
0 |
|
Rs.6200/- |
| 10.1(a)(Design Features(Voltage Rangings)) |
- |
0 |
|
Rs.6200/- |
| 10.1(b)(Design Features(Frequency Rangings)) |
- |
0 |
|
Rs.6200/- |
| 10.1(c)(Design Features(Combination of Voltage and frequency variation)) |
- |
0 |
|
Rs.6200/- |
| 15.2(Guarantee of Performance) |
- |
0 |
|
Rs.6200/- |
| 15(Guarntee on pump performance and tolerances) |
- |
0 |
|
Rs.6200/- |
| 11(General Requirements) |
- |
0 |
|
Rs.6200/- |
| 11.1(The pump shaft should be of adequate size to transmit the required power over the entire head range.) |
- |
0 |
|
Rs.6200/- |
| 11.2(The pump casing should be of robust construction and shall be tested to withstand hydrostatic pressure as specified in 12.3.) |
- |
0 |
|
Rs.6200/- |
| 11.3(The nominal size of suction and delivery pipe of the pump shall be as specified in IS 1239 (Part 1),IS 4984, IS 4985 and IS 12231) |
- |
0 |
|
Rs.6200/- |
| 13.2(Three phase monoset pumps) |
- |
0 |
|
Rs.6200/- |
| 13.2.2(Measurement of stator resistance test (cl.22.3.1(b) of IS 7538)) |
- |
0 |
|
Rs.6200/- |
| 13.2.2(No load test (cl.22.3.1cb) of IS 7538)) |
- |
0 |
|
Rs.6200/- |
| 13.2.2(Reduced voltage running test (cl.22.3.1(d) of IS 7538)) |
- |
0 |
|
Rs.6200/- |
| 13.2.2(Locked Rotor test (cl.22.3.1(e) of IS 7538)) |
- |
0 |
|
Rs.6200/- |
| 13.2.2(Insulation Resistance test (cl.22.3.1(m) of IS 7538)) |
- |
0 |
|
Rs.6200/- |
| 13.2.2(High Voltage test (cl.22.3.1(n) of IS 7538)) |
- |
0 |
|
Rs.6200/- |
| 15.2.1(Monoset pumps) |
- |
0 |
|
Rs.6200/- |
| 15.2.1(a)(Discharge, total head, current and input power at the Guarnteed duty point) |
- |
0 |
|
Rs.6200/- |
| 15.2.1(b)(Non overloading of the prime-mover I the declared operating head range) |
- |
0 |
|
Rs.6200/- |
| 15.2.1(c)(Rated output of motor) |
- |
0 |
|
Rs.6200/- |
| 15.2.1(d)(Full load speed of motor) |
- |
0 |
|
Rs.6200/- |
| 15.2.2(Bare pumps) |
- |
0 |
|
Rs.6200/- |
| 15.2.1(e)(Overall efficiency of pumpset) |
- |
0 |
|
Rs.6200/- |
| 15.2.1(f)(Max.self.priming time) |
- |
0 |
|
Rs.6200/- |
| 15.2.2(a)(Discharge, total head as per Guarnteed duty point at rated voltage and speed) |
- |
0 |
|
Rs.6200/- |
| 15.2.2(b)(Non overloading of the prime-mover I the declared operating head range) |
- |
0 |
|
Rs.6200/- |
| 15.2.2(c)(Non-over-rated prime mover recommended by the manufacturer) |
- |
0 |
|
Rs.6200/- |
| 15.2.2(d)(Max.self.priming time) |
- |
0 |
|
Rs.6200/- |
| 13.2.2.1.1(Temperature rise test at rated voltage) |
- |
0 |
|
Rs.6200/- |
| 13.2.2.1.2(Temperature rise test at reduce voltage) |
- |
0 |
|
Rs.6200/- |
| 13(Type of Enclosures) |
- |
0 |
|
Rs.6200/- |
|
28 Oct, 2028 |
- - |
| 10 |
IS 8034 (2018) |
Submersible pumpsets - Specification (Third Revision) |
- |
8650 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 14(Marking) |
- |
0 |
|
Rs.8650/-3.7kW
Rs.9350/-3.7kWto7.5kW
Rs.10600/-7.5kWto11kW
Rs.13250/-11kW to15kW
Rs.18100/-15 kWto20kW
Rs.20950/-20kWto25kW
Rs.23800/-25kW to 30kW
Rs.26600/- 30kWto35kW
Rs.30150/-35kWto40kW
Rs.31400/-40kWto45kW
Rs.34000/-45kWto50kW |
| 14(Marking) |
- |
0 |
|
Rs.8650/-3.7kW
Rs.9350/-3.7kWto7.5kW
Rs.10600/-7.5kWto11kW
Rs.13250/-11kW to15kW
Rs.18100/-15 kWto20kW
Rs.20950/-20kWto25kW
Rs.23800/-25kW to 30kW
Rs.26600/- 30kWto35kW
Rs.30150/-35kWto40kW
Rs.31400/-40kWto45kW
Rs.34000/-45kWto50kW |
| 14(Marking) |
- |
0 |
|
Rs.8650/-3.7kW
Rs.9350/-3.7kWto7.5kW
Rs.10600/-7.5kWto11kW
Rs.13250/-11kW to15kW
Rs.18100/-15 kWto20kW
Rs.20950/-20kWto25kW
Rs.23800/-25kW to 30kW
Rs.26600/- 30kWto35kW
Rs.30150/-35kWto40kW
Rs.31400/-40kWto45kW
Rs.34000/-45kWto50kW |
| 14(Marking) |
- |
0 |
|
Rs.8650/-3.7kW
Rs.9350/-3.7kWto7.5kW
Rs.10600/-7.5kWto11kW
Rs.13250/-11kW to15kW
Rs.18100/-15 kWto20kW
Rs.20950/-20kWto25kW
Rs.23800/-25kW to 30kW
Rs.26600/- 30kWto35kW
Rs.30150/-35kWto40kW
Rs.31400/-40kWto45kW
Rs.34000/-45kWto50kW |
| 14(Marking) |
- |
0 |
|
Rs.8650/-3.7kW
Rs.9350/-3.7kWto7.5kW
Rs.10600/-7.5kWto11kW
Rs.13250/-11kW to15kW
Rs.18100/-15 kWto20kW
Rs.20950/-20kWto25kW
Rs.23800/-25kW to 30kW
Rs.26600/- 30kWto35kW
Rs.30150/-35kWto40kW
Rs.31400/-40kWto45kW
Rs.34000/-45kWto50kW |
| 14(Marking) |
- |
0 |
|
Rs.8650/-3.7kW
Rs.9350/-3.7kWto7.5kW
Rs.10600/-7.5kWto11kW
Rs.13250/-11kW to15kW
Rs.18100/-15 kWto20kW
Rs.20950/-20kWto25kW
Rs.23800/-25kW to 30kW
Rs.26600/- 30kWto35kW
Rs.30150/-35kWto40kW
Rs.31400/-40kWto45kW
Rs.34000/-45kWto50kW |
| 14(Marking) |
- |
0 |
|
Rs.8650/-3.7kW
Rs.9350/-3.7kWto7.5kW
Rs.10600/-7.5kWto11kW
Rs.13250/-11kW to15kW
Rs.18100/-15 kWto20kW
Rs.20950/-20kWto25kW
Rs.23800/-25kW to 30kW
Rs.26600/- 30kWto35kW
Rs.30150/-35kWto40kW
Rs.31400/-40kWto45kW
Rs.34000/-45kWto50kW |
| 14(Marking) |
- |
0 |
|
Rs.8650/-3.7kW
Rs.9350/-3.7kWto7.5kW
Rs.10600/-7.5kWto11kW
Rs.13250/-11kW to15kW
Rs.18100/-15 kWto20kW
Rs.20950/-20kWto25kW
Rs.23800/-25kW to 30kW
Rs.26600/- 30kWto35kW
Rs.30150/-35kWto40kW
Rs.31400/-40kWto45kW
Rs.34000/-45kWto50kW |
| 14(Marking) |
- |
0 |
|
Rs.8650/-3.7kW
Rs.9350/-3.7kWto7.5kW
Rs.10600/-7.5kWto11kW
Rs.13250/-11kW to15kW
Rs.18100/-15 kWto20kW
Rs.20950/-20kWto25kW
Rs.23800/-25kW to 30kW
Rs.26600/- 30kWto35kW
Rs.30150/-35kWto40kW
Rs.31400/-40kWto45kW
Rs.34000/-45kWto50kW |
| 14(Marking) |
- |
0 |
|
Rs.8650/-3.7kW
Rs.9350/-3.7kWto7.5kW
Rs.10600/-7.5kWto11kW
Rs.13250/-11kW to15kW
Rs.18100/-15 kWto20kW
Rs.20950/-20kWto25kW
Rs.23800/-25kW to 30kW
Rs.26600/- 30kWto35kW
Rs.30150/-35kWto40kW
Rs.31400/-40kWto45kW
Rs.34000/-45kWto50kW |
| 14(Marking) |
- |
0 |
|
Rs.8650/-3.7kW
Rs.9350/-3.7kWto7.5kW
Rs.10600/-7.5kWto11kW
Rs.13250/-11kW to15kW
Rs.18100/-15 kWto20kW
Rs.20950/-20kWto25kW
Rs.23800/-25kW to 30kW
Rs.26600/- 30kWto35kW
Rs.30150/-35kWto40kW
Rs.31400/-40kWto45kW
Rs.34000/-45kWto50kW |
| 14(Marking) |
- |
0 |
|
Rs.8650/-3.7kW
Rs.9350/-3.7kWto7.5kW
Rs.10600/-7.5kWto11kW
Rs.13250/-11kW to15kW
Rs.18100/-15 kWto20kW
Rs.20950/-20kWto25kW
Rs.23800/-25kW to 30kW
Rs.26600/- 30kWto35kW
Rs.30150/-35kWto40kW
Rs.31400/-40kWto45kW
Rs.34000/-45kWto50kW |
| 14(Marking) |
- |
0 |
|
Rs.8650/-3.7kW
Rs.9350/-3.7kWto7.5kW
Rs.10600/-7.5kWto11kW
Rs.13250/-11kW to15kW
Rs.18100/-15 kWto20kW
Rs.20950/-20kWto25kW
Rs.23800/-25kW to 30kW
Rs.26600/- 30kWto35kW
Rs.30150/-35kWto40kW
Rs.31400/-40kWto45kW
Rs.34000/-45kWto50kW |
| 14(Marking) |
- |
0 |
|
Rs.8650/-3.7kW
Rs.9350/-3.7kWto7.5kW
Rs.10600/-7.5kWto11kW
Rs.13250/-11kW to15kW
Rs.18100/-15 kWto20kW
Rs.20950/-20kWto25kW
Rs.23800/-25kW to 30kW
Rs.26600/- 30kWto35kW
Rs.30150/-35kWto40kW
Rs.31400/-40kWto45kW
Rs.34000/-45kWto50kW |
| 14(Marking) |
- |
0 |
|
Rs.8650/-3.7kW
Rs.9350/-3.7kWto7.5kW
Rs.10600/-7.5kWto11kW
Rs.13250/-11kW to15kW
Rs.18100/-15 kWto20kW
Rs.20950/-20kWto25kW
Rs.23800/-25kW to 30kW
Rs.26600/- 30kWto35kW
Rs.30150/-35kWto40kW
Rs.31400/-40kWto45kW
Rs.34000/-45kWto50kW |
| 14(Marking) |
- |
0 |
|
Rs.8650/-3.7kW
Rs.9350/-3.7kWto7.5kW
Rs.10600/-7.5kWto11kW
Rs.13250/-11kW to15kW
Rs.18100/-15 kWto20kW
Rs.20950/-20kWto25kW
Rs.23800/-25kW to 30kW
Rs.26600/- 30kWto35kW
Rs.30150/-35kWto40kW
Rs.31400/-40kWto45kW
Rs.34000/-45kWto50kW |
| 14(Marking) |
- |
0 |
|
Rs.8650/-3.7kW
Rs.9350/-3.7kWto7.5kW
Rs.10600/-7.5kWto11kW
Rs.13250/-11kW to15kW
Rs.18100/-15 kWto20kW
Rs.20950/-20kWto25kW
Rs.23800/-25kW to 30kW
Rs.26600/- 30kWto35kW
Rs.30150/-35kWto40kW
Rs.31400/-40kWto45kW
Rs.34000/-45kWto50kW |
| 14(Marking) |
- |
0 |
|
Rs.8650/-3.7kW
Rs.9350/-3.7kWto7.5kW
Rs.10600/-7.5kWto11kW
Rs.13250/-11kW to15kW
Rs.18100/-15 kWto20kW
Rs.20950/-20kWto25kW
Rs.23800/-25kW to 30kW
Rs.26600/- 30kWto35kW
Rs.30150/-35kWto40kW
Rs.31400/-40kWto45kW
Rs.34000/-45kWto50kW |
| 14(Marking) |
- |
0 |
|
Rs.8650/-3.7kW
Rs.9350/-3.7kWto7.5kW
Rs.10600/-7.5kWto11kW
Rs.13250/-11kW to15kW
Rs.18100/-15 kWto20kW
Rs.20950/-20kWto25kW
Rs.23800/-25kW to 30kW
Rs.26600/- 30kWto35kW
Rs.30150/-35kWto40kW
Rs.31400/-40kWto45kW
Rs.34000/-45kWto50kW |
| 6.1 (a)(Constructional Features) |
- |
0 |
|
Rs.8650/-3.7kW
Rs.9350/-3.7kWto7.5kW
Rs.10600/-7.5kWto11kW
Rs.13250/-11kW to15kW
Rs.18100/-15 kWto20kW
Rs.20950/-20kWto25kW
Rs.23800/-25kW to 30kW
Rs.26600/- 30kWto35kW
Rs.30150/-35kWto40kW
Rs.31400/-40kWto45kW
Rs.34000/-45kWto50kW |
| 6.1 (b)(Constructional Features) |
- |
0 |
|
Rs.8650/-3.7kW
Rs.9350/-3.7kWto7.5kW
Rs.10600/-7.5kWto11kW
Rs.13250/-11kW to15kW
Rs.18100/-15 kWto20kW
Rs.20950/-20kWto25kW
Rs.23800/-25kW to 30kW
Rs.26600/- 30kWto35kW
Rs.30150/-35kWto40kW
Rs.31400/-40kWto45kW
Rs.34000/-45kWto50kW |
| 6.1 (c)(Constructional Features) |
- |
0 |
|
Rs.8650/-3.7kW
Rs.9350/-3.7kWto7.5kW
Rs.10600/-7.5kWto11kW
Rs.13250/-11kW to15kW
Rs.18100/-15 kWto20kW
Rs.20950/-20kWto25kW
Rs.23800/-25kW to 30kW
Rs.26600/- 30kWto35kW
Rs.30150/-35kWto40kW
Rs.31400/-40kWto45kW
Rs.34000/-45kWto50kW |
| 6.1 (d)(Constructional Features) |
- |
0 |
|
Rs.8650/-3.7kW
Rs.9350/-3.7kWto7.5kW
Rs.10600/-7.5kWto11kW
Rs.13250/-11kW to15kW
Rs.18100/-15 kWto20kW
Rs.20950/-20kWto25kW
Rs.23800/-25kW to 30kW
Rs.26600/- 30kWto35kW
Rs.30150/-35kWto40kW
Rs.31400/-40kWto45kW
Rs.34000/-45kWto50kW |
| 6.1 (e)(Constructional Features) |
- |
0 |
|
Rs.8650/-3.7kW
Rs.9350/-3.7kWto7.5kW
Rs.10600/-7.5kWto11kW
Rs.13250/-11kW to15kW
Rs.18100/-15 kWto20kW
Rs.20950/-20kWto25kW
Rs.23800/-25kW to 30kW
Rs.26600/- 30kWto35kW
Rs.30150/-35kWto40kW
Rs.31400/-40kWto45kW
Rs.34000/-45kWto50kW |
| 6.1 (f)(Constructional Features) |
- |
0 |
|
Rs.8650/-3.7kW
Rs.9350/-3.7kWto7.5kW
Rs.10600/-7.5kWto11kW
Rs.13250/-11kW to15kW
Rs.18100/-15 kWto20kW
Rs.20950/-20kWto25kW
Rs.23800/-25kW to 30kW
Rs.26600/- 30kWto35kW
Rs.30150/-35kWto40kW
Rs.31400/-40kWto45kW
Rs.34000/-45kWto50kW |
| 6.2 (a)(Material of construction Part Sub Assembly
Shaft Sleeve) |
- |
0 |
|
Rs.8650/-3.7kW
Rs.9350/-3.7kWto7.5kW
Rs.10600/-7.5kWto11kW
Rs.13250/-11kW to15kW
Rs.18100/-15 kWto20kW
Rs.20950/-20kWto25kW
Rs.23800/-25kW to 30kW
Rs.26600/- 30kWto35kW
Rs.30150/-35kWto40kW
Rs.31400/-40kWto45kW
Rs.34000/-45kWto50kW |
| 6.2 (b)(Material of construction Part Sub Assembly
Casing wear ring
(if provided)) |
- |
0 |
|
Rs.8650/-3.7kW
Rs.9350/-3.7kWto7.5kW
Rs.10600/-7.5kWto11kW
Rs.13250/-11kW to15kW
Rs.18100/-15 kWto20kW
Rs.20950/-20kWto25kW
Rs.23800/-25kW to 30kW
Rs.26600/- 30kWto35kW
Rs.30150/-35kWto40kW
Rs.31400/-40kWto45kW
Rs.34000/-45kWto50kW |
| 6.2 (c)(Material of construction Part Sub Assembly
Bush) |
- |
0 |
|
Rs.8650/-3.7kW
Rs.9350/-3.7kWto7.5kW
Rs.10600/-7.5kWto11kW
Rs.13250/-11kW to15kW
Rs.18100/-15 kWto20kW
Rs.20950/-20kWto25kW
Rs.23800/-25kW to 30kW
Rs.26600/- 30kWto35kW
Rs.30150/-35kWto40kW
Rs.31400/-40kWto45kW
Rs.34000/-45kWto50kW |
| 6.2 (d)(Material of construction Part Sub Assembly
Discharge casing
(if provided)) |
- |
0 |
|
Rs.8650/-3.7kW
Rs.9350/-3.7kWto7.5kW
Rs.10600/-7.5kWto11kW
Rs.13250/-11kW to15kW
Rs.18100/-15 kWto20kW
Rs.20950/-20kWto25kW
Rs.23800/-25kW to 30kW
Rs.26600/- 30kWto35kW
Rs.30150/-35kWto40kW
Rs.31400/-40kWto45kW
Rs.34000/-45kWto50kW |
| 6.2 (e)(Material of construction Part Sub Assembly
Impeller) |
- |
0 |
|
Rs.8650/-3.7kW
Rs.9350/-3.7kWto7.5kW
Rs.10600/-7.5kWto11kW
Rs.13250/-11kW to15kW
Rs.18100/-15 kWto20kW
Rs.20950/-20kWto25kW
Rs.23800/-25kW to 30kW
Rs.26600/- 30kWto35kW
Rs.30150/-35kWto40kW
Rs.31400/-40kWto45kW
Rs.34000/-45kWto50kW |
| 6.2 (f)(Material of construction Part Sub Assembly
Pump Bowl/Diffuser) |
- |
0 |
|
Rs.8650/-3.7kW
Rs.9350/-3.7kWto7.5kW
Rs.10600/-7.5kWto11kW
Rs.13250/-11kW to15kW
Rs.18100/-15 kWto20kW
Rs.20950/-20kWto25kW
Rs.23800/-25kW to 30kW
Rs.26600/- 30kWto35kW
Rs.30150/-35kWto40kW
Rs.31400/-40kWto45kW
Rs.34000/-45kWto50kW |
| 6.2 (g)(Material of construction Part Sub Assembly
Pump Shaft) |
- |
0 |
|
Rs.8650/-3.7kW
Rs.9350/-3.7kWto7.5kW
Rs.10600/-7.5kWto11kW
Rs.13250/-11kW to15kW
Rs.18100/-15 kWto20kW
Rs.20950/-20kWto25kW
Rs.23800/-25kW to 30kW
Rs.26600/- 30kWto35kW
Rs.30150/-35kWto40kW
Rs.31400/-40kWto45kW
Rs.34000/-45kWto50kW |
| 6.2 (h)(Material of construction Part Sub Assembly
Suction Casing) |
- |
0 |
|
Rs.8650/-3.7kW
Rs.9350/-3.7kWto7.5kW
Rs.10600/-7.5kWto11kW
Rs.13250/-11kW to15kW
Rs.18100/-15 kWto20kW
Rs.20950/-20kWto25kW
Rs.23800/-25kW to 30kW
Rs.26600/- 30kWto35kW
Rs.30150/-35kWto40kW
Rs.31400/-40kWto45kW
Rs.34000/-45kWto50kW |
| 6.2.2.1(Gaskets, Seals and Packings) |
- |
0 |
|
Rs.8650/-3.7kW
Rs.9350/-3.7kWto7.5kW
Rs.10600/-7.5kWto11kW
Rs.13250/-11kW to15kW
Rs.18100/-15 kWto20kW
Rs.20950/-20kWto25kW
Rs.23800/-25kW to 30kW
Rs.26600/- 30kWto35kW
Rs.30150/-35kWto40kW
Rs.31400/-40kWto45kW
Rs.34000/-45kWto50kW |
| 6.2.2.2(Gaskets, Seals and Packings) |
- |
0 |
|
Rs.8650/-3.7kW
Rs.9350/-3.7kWto7.5kW
Rs.10600/-7.5kWto11kW
Rs.13250/-11kW to15kW
Rs.18100/-15 kWto20kW
Rs.20950/-20kWto25kW
Rs.23800/-25kW to 30kW
Rs.26600/- 30kWto35kW
Rs.30150/-35kWto40kW
Rs.31400/-40kWto45kW
Rs.34000/-45kWto50kW |
| 6.2.3(Gaskets, Seals and Packings) |
- |
0 |
|
Rs.8650/-3.7kW
Rs.9350/-3.7kWto7.5kW
Rs.10600/-7.5kWto11kW
Rs.13250/-11kW to15kW
Rs.18100/-15 kWto20kW
Rs.20950/-20kWto25kW
Rs.23800/-25kW to 30kW
Rs.26600/- 30kWto35kW
Rs.30150/-35kWto40kW
Rs.31400/-40kWto45kW
Rs.34000/-45kWto50kW |
| 6.2.4(Gaskets, Seals and Packings) |
- |
0 |
|
Rs.8650/-3.7kW
Rs.9350/-3.7kWto7.5kW
Rs.10600/-7.5kWto11kW
Rs.13250/-11kW to15kW
Rs.18100/-15 kWto20kW
Rs.20950/-20kWto25kW
Rs.23800/-25kW to 30kW
Rs.26600/- 30kWto35kW
Rs.30150/-35kWto40kW
Rs.31400/-40kWto45kW
Rs.34000/-45kWto50kW |
| 6.2.5(Gaskets, Seals and Packings) |
- |
0 |
|
Rs.8650/-3.7kW
Rs.9350/-3.7kWto7.5kW
Rs.10600/-7.5kWto11kW
Rs.13250/-11kW to15kW
Rs.18100/-15 kWto20kW
Rs.20950/-20kWto25kW
Rs.23800/-25kW to 30kW
Rs.26600/- 30kWto35kW
Rs.30150/-35kWto40kW
Rs.31400/-40kWto45kW
Rs.34000/-45kWto50kW |
| 7.1.1(Design features:
Typical design features 0f components of pump) |
- |
0 |
|
Rs.8650/-3.7kW
Rs.9350/-3.7kWto7.5kW
Rs.10600/-7.5kWto11kW
Rs.13250/-11kW to15kW
Rs.18100/-15 kWto20kW
Rs.20950/-20kWto25kW
Rs.23800/-25kW to 30kW
Rs.26600/- 30kWto35kW
Rs.30150/-35kWto40kW
Rs.31400/-40kWto45kW
Rs.34000/-45kWto50kW |
| 7.1.2(Design features:
Typical design features 0f components of pump) |
- |
0 |
|
Rs.8650/-3.7kW
Rs.9350/-3.7kWto7.5kW
Rs.10600/-7.5kWto11kW
Rs.13250/-11kW to15kW
Rs.18100/-15 kWto20kW
Rs.20950/-20kWto25kW
Rs.23800/-25kW to 30kW
Rs.26600/- 30kWto35kW
Rs.30150/-35kWto40kW
Rs.31400/-40kWto45kW
Rs.34000/-45kWto50kW |
| 7.1.3(Design features:
Typical design features 0f components of pump) |
- |
0 |
|
Rs.8650/-3.7kW
Rs.9350/-3.7kWto7.5kW
Rs.10600/-7.5kWto11kW
Rs.13250/-11kW to15kW
Rs.18100/-15 kWto20kW
Rs.20950/-20kWto25kW
Rs.23800/-25kW to 30kW
Rs.26600/- 30kWto35kW
Rs.30150/-35kWto40kW
Rs.31400/-40kWto45kW
Rs.34000/-45kWto50kW |
| 7.1.4(Design features:
Typical design features 0f components of pump) |
- |
0 |
|
Rs.8650/-3.7kW
Rs.9350/-3.7kWto7.5kW
Rs.10600/-7.5kWto11kW
Rs.13250/-11kW to15kW
Rs.18100/-15 kWto20kW
Rs.20950/-20kWto25kW
Rs.23800/-25kW to 30kW
Rs.26600/- 30kWto35kW
Rs.30150/-35kWto40kW
Rs.31400/-40kWto45kW
Rs.34000/-45kWto50kW |
| 7.1.5(Design features:
Typical design features 0f components of pump) |
- |
0 |
|
Rs.8650/-3.7kW
Rs.9350/-3.7kWto7.5kW
Rs.10600/-7.5kWto11kW
Rs.13250/-11kW to15kW
Rs.18100/-15 kWto20kW
Rs.20950/-20kWto25kW
Rs.23800/-25kW to 30kW
Rs.26600/- 30kWto35kW
Rs.30150/-35kWto40kW
Rs.31400/-40kWto45kW
Rs.34000/-45kWto50kW |
| 7.1.6(Design features:
Typical design features 0f components of pump) |
- |
0 |
|
Rs.8650/-3.7kW
Rs.9350/-3.7kWto7.5kW
Rs.10600/-7.5kWto11kW
Rs.13250/-11kW to15kW
Rs.18100/-15 kWto20kW
Rs.20950/-20kWto25kW
Rs.23800/-25kW to 30kW
Rs.26600/- 30kWto35kW
Rs.30150/-35kWto40kW
Rs.31400/-40kWto45kW
Rs.34000/-45kWto50kW |
| 8.1(General Requirements) |
- |
0 |
|
Rs.8650/-3.7kW
Rs.9350/-3.7kWto7.5kW
Rs.10600/-7.5kWto11kW
Rs.13250/-11kW to15kW
Rs.18100/-15 kWto20kW
Rs.20950/-20kWto25kW
Rs.23800/-25kW to 30kW
Rs.26600/- 30kWto35kW
Rs.30150/-35kWto40kW
Rs.31400/-40kWto45kW
Rs.34000/-45kWto50kW |
| 8.2(Casing) |
- |
0 |
|
Rs.8650/-3.7kW
Rs.9350/-3.7kWto7.5kW
Rs.10600/-7.5kWto11kW
Rs.13250/-11kW to15kW
Rs.18100/-15 kWto20kW
Rs.20950/-20kWto25kW
Rs.23800/-25kW to 30kW
Rs.26600/- 30kWto35kW
Rs.30150/-35kWto40kW
Rs.31400/-40kWto45kW
Rs.34000/-45kWto50kW |
| 8.3(Impeller) |
- |
0 |
|
Rs.8650/-3.7kW
Rs.9350/-3.7kWto7.5kW
Rs.10600/-7.5kWto11kW
Rs.13250/-11kW to15kW
Rs.18100/-15 kWto20kW
Rs.20950/-20kWto25kW
Rs.23800/-25kW to 30kW
Rs.26600/- 30kWto35kW
Rs.30150/-35kWto40kW
Rs.31400/-40kWto45kW
Rs.34000/-45kWto50kW |
| 8.4.1(Shaft) |
- |
0 |
|
Rs.8650/-3.7kW
Rs.9350/-3.7kWto7.5kW
Rs.10600/-7.5kWto11kW
Rs.13250/-11kW to15kW
Rs.18100/-15 kWto20kW
Rs.20950/-20kWto25kW
Rs.23800/-25kW to 30kW
Rs.26600/- 30kWto35kW
Rs.30150/-35kWto40kW
Rs.31400/-40kWto45kW
Rs.34000/-45kWto50kW |
| 8.4.2(Shaft) |
- |
0 |
|
Rs.8650/-3.7kW
Rs.9350/-3.7kWto7.5kW
Rs.10600/-7.5kWto11kW
Rs.13250/-11kW to15kW
Rs.18100/-15 kWto20kW
Rs.20950/-20kWto25kW
Rs.23800/-25kW to 30kW
Rs.26600/- 30kWto35kW
Rs.30150/-35kWto40kW
Rs.31400/-40kWto45kW
Rs.34000/-45kWto50kW |
| 8.5.1(Balancing) |
- |
0 |
|
Rs.8650/-3.7kW
Rs.9350/-3.7kWto7.5kW
Rs.10600/-7.5kWto11kW
Rs.13250/-11kW to15kW
Rs.18100/-15 kWto20kW
Rs.20950/-20kWto25kW
Rs.23800/-25kW to 30kW
Rs.26600/- 30kWto35kW
Rs.30150/-35kWto40kW
Rs.31400/-40kWto45kW
Rs.34000/-45kWto50kW |
| 8.5.2(Balancing) |
- |
0 |
|
Rs.8650/-3.7kW
Rs.9350/-3.7kWto7.5kW
Rs.10600/-7.5kWto11kW
Rs.13250/-11kW to15kW
Rs.18100/-15 kWto20kW
Rs.20950/-20kWto25kW
Rs.23800/-25kW to 30kW
Rs.26600/- 30kWto35kW
Rs.30150/-35kWto40kW
Rs.31400/-40kWto45kW
Rs.34000/-45kWto50kW |
| 8.7.1(Direction of Rotation) |
- |
0 |
|
Rs.8650/-3.7kW
Rs.9350/-3.7kWto7.5kW
Rs.10600/-7.5kWto11kW
Rs.13250/-11kW to15kW
Rs.18100/-15 kWto20kW
Rs.20950/-20kWto25kW
Rs.23800/-25kW to 30kW
Rs.26600/- 30kWto35kW
Rs.30150/-35kWto40kW
Rs.31400/-40kWto45kW
Rs.34000/-45kWto50kW |
| 8.7.2(Direction of Rotation) |
- |
0 |
|
Rs.8650/-3.7kW
Rs.9350/-3.7kWto7.5kW
Rs.10600/-7.5kWto11kW
Rs.13250/-11kW to15kW
Rs.18100/-15 kWto20kW
Rs.20950/-20kWto25kW
Rs.23800/-25kW to 30kW
Rs.26600/- 30kWto35kW
Rs.30150/-35kWto40kW
Rs.31400/-40kWto45kW
Rs.34000/-45kWto50kW |
| 8.8(Terminal Marking) |
- |
0 |
|
Rs.8650/-3.7kW
Rs.9350/-3.7kWto7.5kW
Rs.10600/-7.5kWto11kW
Rs.13250/-11kW to15kW
Rs.18100/-15 kWto20kW
Rs.20950/-20kWto25kW
Rs.23800/-25kW to 30kW
Rs.26600/- 30kWto35kW
Rs.30150/-35kWto40kW
Rs.31400/-40kWto45kW
Rs.34000/-45kWto50kW |
| 8.9.1(Typical Installation) |
- |
0 |
|
Rs.8650/-3.7kW
Rs.9350/-3.7kWto7.5kW
Rs.10600/-7.5kWto11kW
Rs.13250/-11kW to15kW
Rs.18100/-15 kWto20kW
Rs.20950/-20kWto25kW
Rs.23800/-25kW to 30kW
Rs.26600/- 30kWto35kW
Rs.30150/-35kWto40kW
Rs.31400/-40kWto45kW
Rs.34000/-45kWto50kW |
| 8.9.3(Typical Installation) |
- |
0 |
|
Rs.8650/-3.7kW
Rs.9350/-3.7kWto7.5kW
Rs.10600/-7.5kWto11kW
Rs.13250/-11kW to15kW
Rs.18100/-15 kWto20kW
Rs.20950/-20kWto25kW
Rs.23800/-25kW to 30kW
Rs.26600/- 30kWto35kW
Rs.30150/-35kWto40kW
Rs.31400/-40kWto45kW
Rs.34000/-45kWto50kW |
| 10.2(Laboratory Tests
Cl.8 of IS 11346-2002
Rate of flow and head
Cl.8 of IS 11346-2002) |
- |
0 |
|
Rs.8650/-3.7kW
Rs.9350/-3.7kWto7.5kW
Rs.10600/-7.5kWto11kW
Rs.13250/-11kW to15kW
Rs.18100/-15 kWto20kW
Rs.20950/-20kWto25kW
Rs.23800/-25kW to 30kW
Rs.26600/- 30kWto35kW
Rs.30150/-35kWto40kW
Rs.31400/-40kWto45kW
Rs.34000/-45kWto50kW |
| 10.2(Laboratory Tests
Cl.8 of IS 11346-2002
Rate of flow and head
Cl.8 of IS 11346-2002) |
- |
0 |
|
Rs.8650/-3.7kW
Rs.9350/-3.7kWto7.5kW
Rs.10600/-7.5kWto11kW
Rs.13250/-11kW to15kW
Rs.18100/-15 kWto20kW
Rs.20950/-20kWto25kW
Rs.23800/-25kW to 30kW
Rs.26600/- 30kWto35kW
Rs.30150/-35kWto40kW
Rs.31400/-40kWto45kW
Rs.34000/-45kWto50kW |
| 10.2(Laboratory Tests
Cl.8 of IS 11346-2002
Efficiency
Cl.8.3 of IS 11346-2002) |
- |
0 |
|
Rs.8650/-3.7kW
Rs.9350/-3.7kWto7.5kW
Rs.10600/-7.5kWto11kW
Rs.13250/-11kW to15kW
Rs.18100/-15 kWto20kW
Rs.20950/-20kWto25kW
Rs.23800/-25kW to 30kW
Rs.26600/- 30kWto35kW
Rs.30150/-35kWto40kW
Rs.31400/-40kWto45kW
Rs.34000/-45kWto50kW |
| 10.3(Hydrostatic Pressure Test) |
- |
0 |
|
Rs.8650/-3.7kW
Rs.9350/-3.7kWto7.5kW
Rs.10600/-7.5kWto11kW
Rs.13250/-11kW to15kW
Rs.18100/-15 kWto20kW
Rs.20950/-20kWto25kW
Rs.23800/-25kW to 30kW
Rs.26600/- 30kWto35kW
Rs.30150/-35kWto40kW
Rs.31400/-40kWto45kW
Rs.34000/-45kWto50kW |
| 11.1.1(Guarantee of Performance) |
- |
0 |
|
Rs.8650/-3.7kW
Rs.9350/-3.7kWto7.5kW
Rs.10600/-7.5kWto11kW
Rs.13250/-11kW to15kW
Rs.18100/-15 kWto20kW
Rs.20950/-20kWto25kW
Rs.23800/-25kW to 30kW
Rs.26600/- 30kWto35kW
Rs.30150/-35kWto40kW
Rs.31400/-40kWto45kW
Rs.34000/-45kWto50kW |
| 11.1.2(Guarantee of Performance) |
- |
0 |
|
Rs.8650/-3.7kW
Rs.9350/-3.7kWto7.5kW
Rs.10600/-7.5kWto11kW
Rs.13250/-11kW to15kW
Rs.18100/-15 kWto20kW
Rs.20950/-20kWto25kW
Rs.23800/-25kW to 30kW
Rs.26600/- 30kWto35kW
Rs.30150/-35kWto40kW
Rs.31400/-40kWto45kW
Rs.34000/-45kWto50kW |
| 11.1.2(Guarantee of Performance) |
- |
0 |
|
Rs.8650/-3.7kW
Rs.9350/-3.7kWto7.5kW
Rs.10600/-7.5kWto11kW
Rs.13250/-11kW to15kW
Rs.18100/-15 kWto20kW
Rs.20950/-20kWto25kW
Rs.23800/-25kW to 30kW
Rs.26600/- 30kWto35kW
Rs.30150/-35kWto40kW
Rs.31400/-40kWto45kW
Rs.34000/-45kWto50kW |
| 11.1.3(Guarantee of Performance) |
- |
0 |
|
Rs.8650/-3.7kW
Rs.9350/-3.7kWto7.5kW
Rs.10600/-7.5kWto11kW
Rs.13250/-11kW to15kW
Rs.18100/-15 kWto20kW
Rs.20950/-20kWto25kW
Rs.23800/-25kW to 30kW
Rs.26600/- 30kWto35kW
Rs.30150/-35kWto40kW
Rs.31400/-40kWto45kW
Rs.34000/-45kWto50kW |
| 11.1.4(Guarantee of Performance) |
- |
0 |
|
Rs.8650/-3.7kW
Rs.9350/-3.7kWto7.5kW
Rs.10600/-7.5kWto11kW
Rs.13250/-11kW to15kW
Rs.18100/-15 kWto20kW
Rs.20950/-20kWto25kW
Rs.23800/-25kW to 30kW
Rs.26600/- 30kWto35kW
Rs.30150/-35kWto40kW
Rs.31400/-40kWto45kW
Rs.34000/-45kWto50kW |
| 11.1.5(Guarantee of Performance) |
- |
0 |
|
Rs.8650/-3.7kW
Rs.9350/-3.7kWto7.5kW
Rs.10600/-7.5kWto11kW
Rs.13250/-11kW to15kW
Rs.18100/-15 kWto20kW
Rs.20950/-20kWto25kW
Rs.23800/-25kW to 30kW
Rs.26600/- 30kWto35kW
Rs.30150/-35kWto40kW
Rs.31400/-40kWto45kW
Rs.34000/-45kWto50kW |
| 12(Guarantee of workmanship and material) |
- |
0 |
|
Rs.8650/-3.7kW
Rs.9350/-3.7kWto7.5kW
Rs.10600/-7.5kWto11kW
Rs.13250/-11kW to15kW
Rs.18100/-15 kWto20kW
Rs.20950/-20kWto25kW
Rs.23800/-25kW to 30kW
Rs.26600/- 30kWto35kW
Rs.30150/-35kWto40kW
Rs.31400/-40kWto45kW
Rs.34000/-45kWto50kW |
| 8.9(Typical installation) |
- |
0 |
|
Rs.8650/-3.7kW
Rs.9350/-3.7kWto7.5kW
Rs.10600/-7.5kWto11kW
Rs.13250/-11kW to15kW
Rs.18100/-15 kWto20kW
Rs.20950/-20kWto25kW
Rs.23800/-25kW to 30kW
Rs.26600/- 30kWto35kW
Rs.30150/-35kWto40kW
Rs.31400/-40kWto45kW
Rs.34000/-45kWto50kW |
| 8.5(Balancing of rotor) |
- |
0 |
|
Rs.8650/-3.7kW
Rs.9350/-3.7kWto7.5kW
Rs.10600/-7.5kWto11kW
Rs.13250/-11kW to15kW
Rs.18100/-15 kWto20kW
Rs.20950/-20kWto25kW
Rs.23800/-25kW to 30kW
Rs.26600/- 30kWto35kW
Rs.30150/-35kWto40kW
Rs.31400/-40kWto45kW
Rs.34000/-45kWto50kW |
| 8.6(Submersible cable) |
- |
0 |
|
Rs.8650/-3.7kW
Rs.9350/-3.7kWto7.5kW
Rs.10600/-7.5kWto11kW
Rs.13250/-11kW to15kW
Rs.18100/-15 kWto20kW
Rs.20950/-20kWto25kW
Rs.23800/-25kW to 30kW
Rs.26600/- 30kWto35kW
Rs.30150/-35kWto40kW
Rs.31400/-40kWto45kW
Rs.34000/-45kWto50kW |
| 8.7(Direction of Rotation) |
- |
0 |
|
Rs.8650/-3.7kW
Rs.9350/-3.7kWto7.5kW
Rs.10600/-7.5kWto11kW
Rs.13250/-11kW to15kW
Rs.18100/-15 kWto20kW
Rs.20950/-20kWto25kW
Rs.23800/-25kW to 30kW
Rs.26600/- 30kWto35kW
Rs.30150/-35kWto40kW
Rs.31400/-40kWto45kW
Rs.34000/-45kWto50kW |
| 7(Design features) |
- |
0 |
|
Rs.8650/-3.7kW
Rs.9350/-3.7kWto7.5kW
Rs.10600/-7.5kWto11kW
Rs.13250/-11kW to15kW
Rs.18100/-15 kWto20kW
Rs.20950/-20kWto25kW
Rs.23800/-25kW to 30kW
Rs.26600/- 30kWto35kW
Rs.30150/-35kWto40kW
Rs.31400/-40kWto45kW
Rs.34000/-45kWto50kW |
| 7.1.10(Voltage & Frequency variation) |
- |
0 |
|
Rs.8650/-3.7kW
Rs.9350/-3.7kWto7.5kW
Rs.10600/-7.5kWto11kW
Rs.13250/-11kW to15kW
Rs.18100/-15 kWto20kW
Rs.20950/-20kWto25kW
Rs.23800/-25kW to 30kW
Rs.26600/- 30kWto35kW
Rs.30150/-35kWto40kW
Rs.31400/-40kWto45kW
Rs.34000/-45kWto50kW |
| 6(Measurement of shaft extension) |
- |
0 |
|
Rs.8650/-3.7kW
Rs.9350/-3.7kWto7.5kW
Rs.10600/-7.5kWto11kW
Rs.13250/-11kW to15kW
Rs.18100/-15 kWto20kW
Rs.20950/-20kWto25kW
Rs.23800/-25kW to 30kW
Rs.26600/- 30kWto35kW
Rs.30150/-35kWto40kW
Rs.31400/-40kWto45kW
Rs.34000/-45kWto50kW |
| 6(Constructional Features) |
- |
0 |
|
Rs.8650/-3.7kW
Rs.9350/-3.7kWto7.5kW
Rs.10600/-7.5kWto11kW
Rs.13250/-11kW to15kW
Rs.18100/-15 kWto20kW
Rs.20950/-20kWto25kW
Rs.23800/-25kW to 30kW
Rs.26600/- 30kWto35kW
Rs.30150/-35kWto40kW
Rs.31400/-40kWto45kW
Rs.34000/-45kWto50kW |
| 11(Guarantee of Performance) |
- |
0 |
|
Rs.8650/-3.7kW
Rs.9350/-3.7kWto7.5kW
Rs.10600/-7.5kWto11kW
Rs.13250/-11kW to15kW
Rs.18100/-15 kWto20kW
Rs.20950/-20kWto25kW
Rs.23800/-25kW to 30kW
Rs.26600/- 30kWto35kW
Rs.30150/-35kWto40kW
Rs.31400/-40kWto45kW
Rs.34000/-45kWto50kW |
| 10(Pump Performance test) |
- |
0 |
|
Rs.8650/-3.7kW
Rs.9350/-3.7kWto7.5kW
Rs.10600/-7.5kWto11kW
Rs.13250/-11kW to15kW
Rs.18100/-15 kWto20kW
Rs.20950/-20kWto25kW
Rs.23800/-25kW to 30kW
Rs.26600/- 30kWto35kW
Rs.30150/-35kWto40kW
Rs.31400/-40kWto45kW
Rs.34000/-45kWto50kW |
| 9.1(General) |
- |
0 |
|
Rs.8650/-3.7kW
Rs.9350/-3.7kWto7.5kW
Rs.10600/-7.5kWto11kW
Rs.13250/-11kW to15kW
Rs.18100/-15 kWto20kW
Rs.20950/-20kWto25kW
Rs.23800/-25kW to 30kW
Rs.26600/- 30kWto35kW
Rs.30150/-35kWto40kW
Rs.31400/-40kWto45kW
Rs.34000/-45kWto50kW |
| 9.10 (a)(Insulation Resistance test) |
- |
0 |
|
Rs.8650/-3.7kW
Rs.9350/-3.7kWto7.5kW
Rs.10600/-7.5kWto11kW
Rs.13250/-11kW to15kW
Rs.18100/-15 kWto20kW
Rs.20950/-20kWto25kW
Rs.23800/-25kW to 30kW
Rs.26600/- 30kWto35kW
Rs.30150/-35kWto40kW
Rs.31400/-40kWto45kW
Rs.34000/-45kWto50kW |
| 9.10 (b)(High Voltage test) |
- |
0 |
|
Rs.8650/-3.7kW
Rs.9350/-3.7kWto7.5kW
Rs.10600/-7.5kWto11kW
Rs.13250/-11kW to15kW
Rs.18100/-15 kWto20kW
Rs.20950/-20kWto25kW
Rs.23800/-25kW to 30kW
Rs.26600/- 30kWto35kW
Rs.30150/-35kWto40kW
Rs.31400/-40kWto45kW
Rs.34000/-45kWto50kW |
| 9.10 (c)(Measurement of Stator Resistance) |
- |
0 |
|
Rs.8650/-3.7kW
Rs.9350/-3.7kWto7.5kW
Rs.10600/-7.5kWto11kW
Rs.13250/-11kW to15kW
Rs.18100/-15 kWto20kW
Rs.20950/-20kWto25kW
Rs.23800/-25kW to 30kW
Rs.26600/- 30kWto35kW
Rs.30150/-35kWto40kW
Rs.31400/-40kWto45kW
Rs.34000/-45kWto50kW |
| 9.10 (d)(No Load Test at Rated Voltage) |
- |
0 |
|
Rs.8650/-3.7kW
Rs.9350/-3.7kWto7.5kW
Rs.10600/-7.5kWto11kW
Rs.13250/-11kW to15kW
Rs.18100/-15 kWto20kW
Rs.20950/-20kWto25kW
Rs.23800/-25kW to 30kW
Rs.26600/- 30kWto35kW
Rs.30150/-35kWto40kW
Rs.31400/-40kWto45kW
Rs.34000/-45kWto50kW |
| 9.10 (e)(Reduced voltage Running up test) |
- |
0 |
|
Rs.8650/-3.7kW
Rs.9350/-3.7kWto7.5kW
Rs.10600/-7.5kWto11kW
Rs.13250/-11kW to15kW
Rs.18100/-15 kWto20kW
Rs.20950/-20kWto25kW
Rs.23800/-25kW to 30kW
Rs.26600/- 30kWto35kW
Rs.30150/-35kWto40kW
Rs.31400/-40kWto45kW
Rs.34000/-45kWto50kW |
| 9.10 (f) & (g)(Locked Rotor Test) |
- |
0 |
|
Rs.8650/-3.7kW
Rs.9350/-3.7kWto7.5kW
Rs.10600/-7.5kWto11kW
Rs.13250/-11kW to15kW
Rs.18100/-15 kWto20kW
Rs.20950/-20kWto25kW
Rs.23800/-25kW to 30kW
Rs.26600/- 30kWto35kW
Rs.30150/-35kWto40kW
Rs.31400/-40kWto45kW
Rs.34000/-45kWto50kW |
| 9.10 (h)(Leakage current test) |
- |
0 |
|
Rs.8650/-3.7kW
Rs.9350/-3.7kWto7.5kW
Rs.10600/-7.5kWto11kW
Rs.13250/-11kW to15kW
Rs.18100/-15 kWto20kW
Rs.20950/-20kWto25kW
Rs.23800/-25kW to 30kW
Rs.26600/- 30kWto35kW
Rs.30150/-35kWto40kW
Rs.31400/-40kWto45kW
Rs.34000/-45kWto50kW |
| 9.10 (j)(Temperature Rise Test at Rated Voltage) |
- |
0 |
|
Rs.8650/-3.7kW
Rs.9350/-3.7kWto7.5kW
Rs.10600/-7.5kWto11kW
Rs.13250/-11kW to15kW
Rs.18100/-15 kWto20kW
Rs.20950/-20kWto25kW
Rs.23800/-25kW to 30kW
Rs.26600/- 30kWto35kW
Rs.30150/-35kWto40kW
Rs.31400/-40kWto45kW
Rs.34000/-45kWto50kW |
| 9.10 (k)(Temperature rise test at reduced voltage) |
- |
0 |
|
Rs.8650/-3.7kW
Rs.9350/-3.7kWto7.5kW
Rs.10600/-7.5kWto11kW
Rs.13250/-11kW to15kW
Rs.18100/-15 kWto20kW
Rs.20950/-20kWto25kW
Rs.23800/-25kW to 30kW
Rs.26600/- 30kWto35kW
Rs.30150/-35kWto40kW
Rs.31400/-40kWto45kW
Rs.34000/-45kWto50kW |
| 8.9.4c(Earthing) |
- |
0 |
|
Rs.8650/-3.7kW
Rs.9350/-3.7kWto7.5kW
Rs.10600/-7.5kWto11kW
Rs.13250/-11kW to15kW
Rs.18100/-15 kWto20kW
Rs.20950/-20kWto25kW
Rs.23800/-25kW to 30kW
Rs.26600/- 30kWto35kW
Rs.30150/-35kWto40kW
Rs.31400/-40kWto45kW
Rs.34000/-45kWto50kW |
| 7.1.7(Pump loading shall be as per 11.1.5) |
- |
0 |
|
Rs.8650/-3.7kW
Rs.9350/-3.7kWto7.5kW
Rs.10600/-7.5kWto11kW
Rs.13250/-11kW to15kW
Rs.18100/-15 kWto20kW
Rs.20950/-20kWto25kW
Rs.23800/-25kW to 30kW
Rs.26600/- 30kWto35kW
Rs.30150/-35kWto40kW
Rs.31400/-40kWto45kW
Rs.34000/-45kWto50kW |
| 7.1.9(prime mover electric motor suitable for the pumps shall be of contineous duty as specified in IS/IEC 60034-4 and as per IS 9283) |
- |
0 |
|
Rs.8650/-3.7kW
Rs.9350/-3.7kWto7.5kW
Rs.10600/-7.5kWto11kW
Rs.13250/-11kW to15kW
Rs.18100/-15 kWto20kW
Rs.20950/-20kWto25kW
Rs.23800/-25kW to 30kW
Rs.26600/- 30kWto35kW
Rs.30150/-35kWto40kW
Rs.31400/-40kWto45kW
Rs.34000/-45kWto50kW |
| 8.6.1(Flat/Round cables as per IS694 shall be used) |
- |
0 |
|
Rs.8650/-3.7kW
Rs.9350/-3.7kWto7.5kW
Rs.10600/-7.5kWto11kW
Rs.13250/-11kW to15kW
Rs.18100/-15 kWto20kW
Rs.20950/-20kWto25kW
Rs.23800/-25kW to 30kW
Rs.26600/- 30kWto35kW
Rs.30150/-35kWto40kW
Rs.31400/-40kWto45kW
Rs.34000/-45kWto50kW |
| 8.6.2(The size of the conductor shall be adequate and suitable for contineous use under water and in air.
the length of the cable shall be minimum 2 m externallly unless otherwise specified by the customer) |
- |
0 |
|
Rs.8650/-3.7kW
Rs.9350/-3.7kWto7.5kW
Rs.10600/-7.5kWto11kW
Rs.13250/-11kW to15kW
Rs.18100/-15 kWto20kW
Rs.20950/-20kWto25kW
Rs.23800/-25kW to 30kW
Rs.26600/- 30kWto35kW
Rs.30150/-35kWto40kW
Rs.31400/-40kWto45kW
Rs.34000/-45kWto50kW |
| 8.6.3(The size and of the cable should be suitably selected so that the voltage drop between control panel and the mptor terminal does not
exeed three percent of the rated voltage) |
- |
0 |
|
Rs.8650/-3.7kW
Rs.9350/-3.7kWto7.5kW
Rs.10600/-7.5kWto11kW
Rs.13250/-11kW to15kW
Rs.18100/-15 kWto20kW
Rs.20950/-20kWto25kW
Rs.23800/-25kW to 30kW
Rs.26600/- 30kWto35kW
Rs.30150/-35kWto40kW
Rs.31400/-40kWto45kW
Rs.34000/-45kWto50kW |
| 8.6.4(In case a joint is required to be made between the lead cable supplied with the motor and the user’s cable, a detailed procedure to
make water tight joining shall be supplied by the motor manufacturer.) |
- |
0 |
|
Rs.8650/-3.7kW
Rs.9350/-3.7kWto7.5kW
Rs.10600/-7.5kWto11kW
Rs.13250/-11kW to15kW
Rs.18100/-15 kWto20kW
Rs.20950/-20kWto25kW
Rs.23800/-25kW to 30kW
Rs.26600/- 30kWto35kW
Rs.30150/-35kWto40kW
Rs.31400/-40kWto45kW
Rs.34000/-45kWto50kW |
| 8.9(Installation) |
- |
0 |
|
Rs.8650/-3.7kW
Rs.9350/-3.7kWto7.5kW
Rs.10600/-7.5kWto11kW
Rs.13250/-11kW to15kW
Rs.18100/-15 kWto20kW
Rs.20950/-20kWto25kW
Rs.23800/-25kW to 30kW
Rs.26600/- 30kWto35kW
Rs.30150/-35kWto40kW
Rs.31400/-40kWto45kW
Rs.34000/-45kWto50kW |
| 8.9.2(The pumpset shall be installed as per guidelines laid down in IS 14536 or as per the recommendation of the manufacturer) |
- |
0 |
|
Rs.8650/-3.7kW
Rs.9350/-3.7kWto7.5kW
Rs.10600/-7.5kWto11kW
Rs.13250/-11kW to15kW
Rs.18100/-15 kWto20kW
Rs.20950/-20kWto25kW
Rs.23800/-25kW to 30kW
Rs.26600/- 30kWto35kW
Rs.30150/-35kWto40kW
Rs.31400/-40kWto45kW
Rs.34000/-45kWto50kW |
| 8.9.4.1(Earthing of the motor shall be done as per IS 9283 in accordance with the relevant provisions of IS 3043.) |
- |
0 |
|
Rs.8650/-3.7kW
Rs.9350/-3.7kWto7.5kW
Rs.10600/-7.5kWto11kW
Rs.13250/-11kW to15kW
Rs.18100/-15 kWto20kW
Rs.20950/-20kWto25kW
Rs.23800/-25kW to 30kW
Rs.26600/- 30kWto35kW
Rs.30150/-35kWto40kW
Rs.31400/-40kWto45kW
Rs.34000/-45kWto50kW |
| 8.9.4.2(In case of PVC pipes used as discharge pipe, a separate non corrosive, low resistance conductor from motor earth terminal to control
panel earth terminal shall be provided for earthing.) |
- |
0 |
|
Rs.8650/-3.7kW
Rs.9350/-3.7kWto7.5kW
Rs.10600/-7.5kWto11kW
Rs.13250/-11kW to15kW
Rs.18100/-15 kWto20kW
Rs.20950/-20kWto25kW
Rs.23800/-25kW to 30kW
Rs.26600/- 30kWto35kW
Rs.30150/-35kWto40kW
Rs.31400/-40kWto45kW
Rs.34000/-45kWto50kW |
| 8.9.4.3(In case non corrosive GI pipes and clamps are used for the purpose of earthing the motor, earthing connection may be made to
the discharge pipe clamp and to the control panel earth terminal) |
- |
0 |
|
Rs.8650/-3.7kW
Rs.9350/-3.7kWto7.5kW
Rs.10600/-7.5kWto11kW
Rs.13250/-11kW to15kW
Rs.18100/-15 kWto20kW
Rs.20950/-20kWto25kW
Rs.23800/-25kW to 30kW
Rs.26600/- 30kWto35kW
Rs.30150/-35kWto40kW
Rs.31400/-40kWto45kW
Rs.34000/-45kWto50kW |
| 9.10 m(Momentary over-load test) |
- |
0 |
|
Rs.8650/-3.7kW
Rs.9350/-3.7kWto7.5kW
Rs.10600/-7.5kWto11kW
Rs.13250/-11kW to15kW
Rs.18100/-15 kWto20kW
Rs.20950/-20kWto25kW
Rs.23800/-25kW to 30kW
Rs.26600/- 30kWto35kW
Rs.30150/-35kWto40kW
Rs.31400/-40kWto45kW
Rs.34000/-45kWto50kW |
| 9.8(Speed) |
- |
0 |
|
Rs.8650/-3.7kW
Rs.9350/-3.7kWto7.5kW
Rs.10600/-7.5kWto11kW
Rs.13250/-11kW to15kW
Rs.18100/-15 kWto20kW
Rs.20950/-20kWto25kW
Rs.23800/-25kW to 30kW
Rs.26600/- 30kWto35kW
Rs.30150/-35kWto40kW
Rs.31400/-40kWto45kW
Rs.34000/-45kWto50kW |
| 9.7(Breakaway (Starting)Torque Test) |
- |
0 |
|
Rs.8650/-3.7kW
Rs.9350/-3.7kWto7.5kW
Rs.10600/-7.5kWto11kW
Rs.13250/-11kW to15kW
Rs.18100/-15 kWto20kW
Rs.20950/-20kWto25kW
Rs.23800/-25kW to 30kW
Rs.26600/- 30kWto35kW
Rs.30150/-35kWto40kW
Rs.31400/-40kWto45kW
Rs.34000/-45kWto50kW |
| 8.1(GENERAL REQUIREMENTS) |
- |
0 |
|
Rs.8650/-3.7kW
Rs.9350/-3.7kWto7.5kW
Rs.10600/-7.5kWto11kW
Rs.13250/-11kW to15kW
Rs.18100/-15 kWto20kW
Rs.20950/-20kWto25kW
Rs.23800/-25kW to 30kW
Rs.26600/- 30kWto35kW
Rs.30150/-35kWto40kW
Rs.31400/-40kWto45kW
Rs.34000/-45kWto50kW |
| 10.2.1(Measurement of Total Head) |
- |
0 |
|
Rs.8650/-3.7kW
Rs.9350/-3.7kWto7.5kW
Rs.10600/-7.5kWto11kW
Rs.13250/-11kW to15kW
Rs.18100/-15 kWto20kW
Rs.20950/-20kWto25kW
Rs.23800/-25kW to 30kW
Rs.26600/- 30kWto35kW
Rs.30150/-35kWto40kW
Rs.31400/-40kWto45kW
Rs.34000/-45kWto50kW |
| 10.2.2(Flow Measurement) |
- |
0 |
|
Rs.8650/-3.7kW
Rs.9350/-3.7kWto7.5kW
Rs.10600/-7.5kWto11kW
Rs.13250/-11kW to15kW
Rs.18100/-15 kWto20kW
Rs.20950/-20kWto25kW
Rs.23800/-25kW to 30kW
Rs.26600/- 30kWto35kW
Rs.30150/-35kWto40kW
Rs.31400/-40kWto45kW
Rs.34000/-45kWto50kW |
|
28 Oct, 2028 |
- - |
| 11 |
IS 9079 (2018) |
Monoset pumps for clear, cold water for agricultural and water supply purposes - Specification (Third Revision) |
- |
6900 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 10.1(GENERAL REQUIREMENTS
Casing) |
- |
0 |
|
Rs.6250/- for single phase upto 1.5 kW;
For three phase : Rs.6900/- upto 3.7 kW,
Rs.7600/- Above 3.7 kW & upto 7.5 kW,
Rs.9100/- Above 7.5 kW & upto 11.0 kW,
Rs.10150/- Above 11.0 kW & upto 15.0 kW |
| 10.2(GENERAL REQUIREMENTS
Impeller) |
- |
0 |
|
Rs.6250/- for single phase upto 1.5 kW;
For three phase : Rs.6900/- upto 3.7 kW,
Rs.7600/- Above 3.7 kW & upto 7.5 kW,
Rs.9100/- Above 7.5 kW & upto 11.0 kW,
Rs.10150/- Above 11.0 kW & upto 15.0 kW |
| 10.3(GENERAL REQUIREMENTS
Shaft) |
- |
0 |
|
Rs.6250/- for single phase upto 1.5 kW;
For three phase : Rs.6900/- upto 3.7 kW,
Rs.7600/- Above 3.7 kW & upto 7.5 kW,
Rs.9100/- Above 7.5 kW & upto 11.0 kW,
Rs.10150/- Above 11.0 kW & upto 15.0 kW |
| 7.1(DIRECTION OF ROTATION (Cl 7)) |
- |
0 |
|
Rs.6250/- for single phase upto 1.5 kW;
For three phase : Rs.6900/- upto 3.7 kW,
Rs.7600/- Above 3.7 kW & upto 7.5 kW,
Rs.9100/- Above 7.5 kW & upto 11.0 kW,
Rs.10150/- Above 11.0 kW & upto 15.0 kW |
| 7.2(DIRECTION OF ROTATION (Cl 7)) |
- |
0 |
|
Rs.6250/- for single phase upto 1.5 kW;
For three phase : Rs.6900/- upto 3.7 kW,
Rs.7600/- Above 3.7 kW & upto 7.5 kW,
Rs.9100/- Above 7.5 kW & upto 11.0 kW,
Rs.10150/- Above 11.0 kW & upto 15.0 kW |
| 9.1(DESIGN
FEATURES (Cl 9)) |
- |
0 |
|
Rs.6250/- for single phase upto 1.5 kW;
For three phase : Rs.6900/- upto 3.7 kW,
Rs.7600/- Above 3.7 kW & upto 7.5 kW,
Rs.9100/- Above 7.5 kW & upto 11.0 kW,
Rs.10150/- Above 11.0 kW & upto 15.0 kW |
| 9.2(DESIGN
FEATURES (Cl 9)) |
- |
0 |
|
Rs.6250/- for single phase upto 1.5 kW;
For three phase : Rs.6900/- upto 3.7 kW,
Rs.7600/- Above 3.7 kW & upto 7.5 kW,
Rs.9100/- Above 7.5 kW & upto 11.0 kW,
Rs.10150/- Above 11.0 kW & upto 15.0 kW |
| 13.1(Guarantee and tolerances on Pump Performance (Cl 13)) |
- |
0 |
|
Rs.6250/- for single phase upto 1.5 kW;
For three phase : Rs.6900/- upto 3.7 kW,
Rs.7600/- Above 3.7 kW & upto 7.5 kW,
Rs.9100/- Above 7.5 kW & upto 11.0 kW,
Rs.10150/- Above 11.0 kW & upto 15.0 kW |
| 13.2(Guarantee and tolerances on Pump Performance (Cl 13)) |
- |
0 |
|
Rs.6250/- for single phase upto 1.5 kW;
For three phase : Rs.6900/- upto 3.7 kW,
Rs.7600/- Above 3.7 kW & upto 7.5 kW,
Rs.9100/- Above 7.5 kW & upto 11.0 kW,
Rs.10150/- Above 11.0 kW & upto 15.0 kW |
| 8.2 IS 11346 : 2002(Verification of Guarantee
Rate of flow and head
(Cl.8.2 IS 11346 : 2002)) |
- |
0 |
|
Rs.6250/- for single phase upto 1.5 kW;
For three phase : Rs.6900/- upto 3.7 kW,
Rs.7600/- Above 3.7 kW & upto 7.5 kW,
Rs.9100/- Above 7.5 kW & upto 11.0 kW,
Rs.10150/- Above 11.0 kW & upto 15.0 kW |
| 8.2 IS 11346 : 2002(Verification of Guarantee
Rate of flow and head
(Cl.8.2 IS 11346 : 2002)) |
- |
0 |
|
Rs.6250/- for single phase upto 1.5 kW;
For three phase : Rs.6900/- upto 3.7 kW,
Rs.7600/- Above 3.7 kW & upto 7.5 kW,
Rs.9100/- Above 7.5 kW & upto 11.0 kW,
Rs.10150/- Above 11.0 kW & upto 15.0 kW |
| 12.5(Efficiency) |
- |
0 |
|
Rs.6250/- for single phase upto 1.5 kW;
For three phase : Rs.6900/- upto 3.7 kW,
Rs.7600/- Above 3.7 kW & upto 7.5 kW,
Rs.9100/- Above 7.5 kW & upto 11.0 kW,
Rs.10150/- Above 11.0 kW & upto 15.0 kW |
| Cl.8.3 b IS 11346 : 2002(Overall efficiency) |
- |
0 |
|
Rs.6250/- for single phase upto 1.5 kW;
For three phase : Rs.6900/- upto 3.7 kW,
Rs.7600/- Above 3.7 kW & upto 7.5 kW,
Rs.9100/- Above 7.5 kW & upto 11.0 kW,
Rs.10150/- Above 11.0 kW & upto 15.0 kW |
| Cl13.2.3 IS 9079:2002(Current consumption) |
- |
0 |
|
Rs.6250/- for single phase upto 1.5 kW;
For three phase : Rs.6900/- upto 3.7 kW,
Rs.7600/- Above 3.7 kW & upto 7.5 kW,
Rs.9100/- Above 7.5 kW & upto 11.0 kW,
Rs.10150/- Above 11.0 kW & upto 15.0 kW |
| 9.1(DESIGN
FEATURES (Cl 9)) |
- |
0 |
|
Rs.6250/- for single phase upto 1.5 kW;
For three phase : Rs.6900/- upto 3.7 kW,
Rs.7600/- Above 3.7 kW & upto 7.5 kW,
Rs.9100/- Above 7.5 kW & upto 11.0 kW,
Rs.10150/- Above 11.0 kW & upto 15.0 kW |
| 9.2(DESIGN
FEATURES (Cl 9)) |
- |
0 |
|
Rs.6250/- for single phase upto 1.5 kW;
For three phase : Rs.6900/- upto 3.7 kW,
Rs.7600/- Above 3.7 kW & upto 7.5 kW,
Rs.9100/- Above 7.5 kW & upto 11.0 kW,
Rs.10150/- Above 11.0 kW & upto 15.0 kW |
| 13.1(Guarantee and tolerances on Pump Performance (Cl 13)) |
- |
0 |
|
Rs.6250/- for single phase upto 1.5 kW;
For three phase : Rs.6900/- upto 3.7 kW,
Rs.7600/- Above 3.7 kW & upto 7.5 kW,
Rs.9100/- Above 7.5 kW & upto 11.0 kW,
Rs.10150/- Above 11.0 kW & upto 15.0 kW |
| 13.2(Guarantee and tolerances on Pump Performance (Cl 13)) |
- |
0 |
|
Rs.6250/- for single phase upto 1.5 kW;
For three phase : Rs.6900/- upto 3.7 kW,
Rs.7600/- Above 3.7 kW & upto 7.5 kW,
Rs.9100/- Above 7.5 kW & upto 11.0 kW,
Rs.10150/- Above 11.0 kW & upto 15.0 kW |
| 13.1.1 (8.2 of IS 11346 : 2002)(Verification of Guarantee
Rate of flow and head
(Cl.8.2 IS 11346 : 2002)) |
- |
0 |
|
Rs.6250/- for single phase upto 1.5 kW;
For three phase : Rs.6900/- upto 3.7 kW,
Rs.7600/- Above 3.7 kW & upto 7.5 kW,
Rs.9100/- Above 7.5 kW & upto 11.0 kW,
Rs.10150/- Above 11.0 kW & upto 15.0 kW |
| 13.1.1 (8.2 of IS 11346 : 2002)(Verification of Guarantee
Rate of flow and head
(Cl.8.2 IS 11346 : 2002)) |
- |
0 |
|
Rs.6250/- for single phase upto 1.5 kW;
For three phase : Rs.6900/- upto 3.7 kW,
Rs.7600/- Above 3.7 kW & upto 7.5 kW,
Rs.9100/- Above 7.5 kW & upto 11.0 kW,
Rs.10150/- Above 11.0 kW & upto 15.0 kW |
| 12.5(Efficiency) |
- |
0 |
|
Rs.6250/- for single phase upto 1.5 kW;
For three phase : Rs.6900/- upto 3.7 kW,
Rs.7600/- Above 3.7 kW & upto 7.5 kW,
Rs.9100/- Above 7.5 kW & upto 11.0 kW,
Rs.10150/- Above 11.0 kW & upto 15.0 kW |
| Cl.8.3 b IS 11346 : 2002(Overall efficiency) |
- |
0 |
|
Rs.6250/- for single phase upto 1.5 kW;
For three phase : Rs.6900/- upto 3.7 kW,
Rs.7600/- Above 3.7 kW & upto 7.5 kW,
Rs.9100/- Above 7.5 kW & upto 11.0 kW,
Rs.10150/- Above 11.0 kW & upto 15.0 kW |
| Cl13.2.3 IS 9079:2002(Current consumption) |
- |
0 |
|
Rs.6250/- for single phase upto 1.5 kW;
For three phase : Rs.6900/- upto 3.7 kW,
Rs.7600/- Above 3.7 kW & upto 7.5 kW,
Rs.9100/- Above 7.5 kW & upto 11.0 kW,
Rs.10150/- Above 11.0 kW & upto 15.0 kW |
| 7(Contructional Features) |
- |
0 |
|
Rs.6250/- for single phase upto 1.5 kW;
For three phase : Rs.6900/- upto 3.7 kW,
Rs.7600/- Above 3.7 kW & upto 7.5 kW,
Rs.9100/- Above 7.5 kW & upto 11.0 kW,
Rs.10150/- Above 11.0 kW & upto 15.0 kW |
| 7.1(Material of Construction) |
- |
0 |
|
Rs.6250/- for single phase upto 1.5 kW;
For three phase : Rs.6900/- upto 3.7 kW,
Rs.7600/- Above 3.7 kW & upto 7.5 kW,
Rs.9100/- Above 7.5 kW & upto 11.0 kW,
Rs.10150/- Above 11.0 kW & upto 15.0 kW |
| 7.2(Gaskets.Seals and packings) |
- |
0 |
|
Rs.6250/- for single phase upto 1.5 kW;
For three phase : Rs.6900/- upto 3.7 kW,
Rs.7600/- Above 3.7 kW & upto 7.5 kW,
Rs.9100/- Above 7.5 kW & upto 11.0 kW,
Rs.10150/- Above 11.0 kW & upto 15.0 kW |
| 9(Design Features) |
- |
0 |
|
Rs.6250/- for single phase upto 1.5 kW;
For three phase : Rs.6900/- upto 3.7 kW,
Rs.7600/- Above 3.7 kW & upto 7.5 kW,
Rs.9100/- Above 7.5 kW & upto 11.0 kW,
Rs.10150/- Above 11.0 kW & upto 15.0 kW |
| 9.1.1(The pump may be equipped with replaceable bearing and wearing ring, wherever provided.) |
- |
0 |
|
Rs.6250/- for single phase upto 1.5 kW;
For three phase : Rs.6900/- upto 3.7 kW,
Rs.7600/- Above 3.7 kW & upto 7.5 kW,
Rs.9100/- Above 7.5 kW & upto 11.0 kW,
Rs.10150/- Above 11.0 kW & upto 15.0 kW |
| 9.1.2(The pump shall be capable to perform as per guaranteed duty point at the manometric suction lift as specified in Table 1.) |
- |
0 |
|
Rs.6250/- for single phase upto 1.5 kW;
For three phase : Rs.6900/- upto 3.7 kW,
Rs.7600/- Above 3.7 kW & upto 7.5 kW,
Rs.9100/- Above 7.5 kW & upto 11.0 kW,
Rs.10150/- Above 11.0 kW & upto 15.0 kW |
| 9.3(The manufacturer shall have a system of controlling dimensional accuracy within a scheme of fits and tolerance limits.
The system shall help interchangeability and fitment at site for replacement spares during subsequent repair and maintenance.) |
- |
0 |
|
Rs.6250/- for single phase upto 1.5 kW;
For three phase : Rs.6900/- upto 3.7 kW,
Rs.7600/- Above 3.7 kW & upto 7.5 kW,
Rs.9100/- Above 7.5 kW & upto 11.0 kW,
Rs.10150/- Above 11.0 kW & upto 15.0 kW |
| 9.4(The pump efficiency of monoset pumps at duty point as declared by the manufacturer for 2 and 4 poles shall not be less than given in
Fig. 3 to Fig. 6 and beyond this range, the efficiency shall be declared by manufacturer.) |
- |
0 |
|
Rs.6250/- for single phase upto 1.5 kW;
For three phase : Rs.6900/- upto 3.7 kW,
Rs.7600/- Above 3.7 kW & upto 7.5 kW,
Rs.9100/- Above 7.5 kW & upto 11.0 kW,
Rs.10150/- Above 11.0 kW & upto 15.0 kW |
| 10(General Requirements) |
- |
0 |
|
Rs.6250/- for single phase upto 1.5 kW;
For three phase : Rs.6900/- upto 3.7 kW,
Rs.7600/- Above 3.7 kW & upto 7.5 kW,
Rs.9100/- Above 7.5 kW & upto 11.0 kW,
Rs.10150/- Above 11.0 kW & upto 15.0 kW |
| 10.1(General Requirements(Casing)) |
- |
0 |
|
Rs.6250/- for single phase upto 1.5 kW;
For three phase : Rs.6900/- upto 3.7 kW,
Rs.7600/- Above 3.7 kW & upto 7.5 kW,
Rs.9100/- Above 7.5 kW & upto 11.0 kW,
Rs.10150/- Above 11.0 kW & upto 15.0 kW |
| 10.2(General Requirements(Impeller)) |
- |
0 |
|
Rs.6250/- for single phase upto 1.5 kW;
For three phase : Rs.6900/- upto 3.7 kW,
Rs.7600/- Above 3.7 kW & upto 7.5 kW,
Rs.9100/- Above 7.5 kW & upto 11.0 kW,
Rs.10150/- Above 11.0 kW & upto 15.0 kW |
| 10.3(General Requirements(Shaft)) |
- |
0 |
|
Rs.6250/- for single phase upto 1.5 kW;
For three phase : Rs.6900/- upto 3.7 kW,
Rs.7600/- Above 3.7 kW & upto 7.5 kW,
Rs.9100/- Above 7.5 kW & upto 11.0 kW,
Rs.10150/- Above 11.0 kW & upto 15.0 kW |
| 10.4.1, 10.4.2, 10.4.3, 10.4.4(General Requirements(Balancing)) |
- |
0 |
|
Rs.6250/- for single phase upto 1.5 kW;
For three phase : Rs.6900/- upto 3.7 kW,
Rs.7600/- Above 3.7 kW & upto 7.5 kW,
Rs.9100/- Above 7.5 kW & upto 11.0 kW,
Rs.10150/- Above 11.0 kW & upto 15.0 kW |
| 10.5(Provision of Earthing) |
- |
0 |
|
Rs.6250/- for single phase upto 1.5 kW;
For three phase : Rs.6900/- upto 3.7 kW,
Rs.7600/- Above 3.7 kW & upto 7.5 kW,
Rs.9100/- Above 7.5 kW & upto 11.0 kW,
Rs.10150/- Above 11.0 kW & upto 15.0 kW |
| 10.6.1(Terminal Marking) |
- |
0 |
|
Rs.6250/- for single phase upto 1.5 kW;
For three phase : Rs.6900/- upto 3.7 kW,
Rs.7600/- Above 3.7 kW & upto 7.5 kW,
Rs.9100/- Above 7.5 kW & upto 11.0 kW,
Rs.10150/- Above 11.0 kW & upto 15.0 kW |
| 10.6.2, 10.6.3(Direction of Rotation) |
- |
0 |
|
Rs.6250/- for single phase upto 1.5 kW;
For three phase : Rs.6900/- upto 3.7 kW,
Rs.7600/- Above 3.7 kW & upto 7.5 kW,
Rs.9100/- Above 7.5 kW & upto 11.0 kW,
Rs.10150/- Above 11.0 kW & upto 15.0 kW |
| 11.8(Type test) |
- |
0 |
|
Rs.6250/- for single phase upto 1.5 kW;
For three phase : Rs.6900/- upto 3.7 kW,
Rs.7600/- Above 3.7 kW & upto 7.5 kW,
Rs.9100/- Above 7.5 kW & upto 11.0 kW,
Rs.10150/- Above 11.0 kW & upto 15.0 kW |
| 11.8.1(a)(Measurement of stator resistance) |
- |
0 |
|
Rs.6250/- for single phase upto 1.5 kW;
For three phase : Rs.6900/- upto 3.7 kW,
Rs.7600/- Above 3.7 kW & upto 7.5 kW,
Rs.9100/- Above 7.5 kW & upto 11.0 kW,
Rs.10150/- Above 11.0 kW & upto 15.0 kW |
| 11.8.1(b)(High Voltage test) |
- |
0 |
|
Rs.6250/- for single phase upto 1.5 kW;
For three phase : Rs.6900/- upto 3.7 kW,
Rs.7600/- Above 3.7 kW & upto 7.5 kW,
Rs.9100/- Above 7.5 kW & upto 11.0 kW,
Rs.10150/- Above 11.0 kW & upto 15.0 kW |
| 11.8.1(c)(Insulation Resistance test) |
- |
0 |
|
Rs.6250/- for single phase upto 1.5 kW;
For three phase : Rs.6900/- upto 3.7 kW,
Rs.7600/- Above 3.7 kW & upto 7.5 kW,
Rs.9100/- Above 7.5 kW & upto 11.0 kW,
Rs.10150/- Above 11.0 kW & upto 15.0 kW |
| 11.8.1(d)(No load test at rated voltage) |
- |
0 |
|
Rs.6250/- for single phase upto 1.5 kW;
For three phase : Rs.6900/- upto 3.7 kW,
Rs.7600/- Above 3.7 kW & upto 7.5 kW,
Rs.9100/- Above 7.5 kW & upto 11.0 kW,
Rs.10150/- Above 11.0 kW & upto 15.0 kW |
| 11.8.1(e)(Locked rotor) |
- |
0 |
|
Rs.6250/- for single phase upto 1.5 kW;
For three phase : Rs.6900/- upto 3.7 kW,
Rs.7600/- Above 3.7 kW & upto 7.5 kW,
Rs.9100/- Above 7.5 kW & upto 11.0 kW,
Rs.10150/- Above 11.0 kW & upto 15.0 kW |
| 11.8.1(f)(Breakaway (starting) torque) |
- |
0 |
|
Rs.6250/- for single phase upto 1.5 kW;
For three phase : Rs.6900/- upto 3.7 kW,
Rs.7600/- Above 3.7 kW & upto 7.5 kW,
Rs.9100/- Above 7.5 kW & upto 11.0 kW,
Rs.10150/- Above 11.0 kW & upto 15.0 kW |
| 11.8.1(g)(Reduced voltage running up test at no load) |
- |
0 |
|
Rs.6250/- for single phase upto 1.5 kW;
For three phase : Rs.6900/- upto 3.7 kW,
Rs.7600/- Above 3.7 kW & upto 7.5 kW,
Rs.9100/- Above 7.5 kW & upto 11.0 kW,
Rs.10150/- Above 11.0 kW & upto 15.0 kW |
| 11.8.1(h)(Temperature rise test at rated voltage) |
- |
0 |
|
Rs.6250/- for single phase upto 1.5 kW;
For three phase : Rs.6900/- upto 3.7 kW,
Rs.7600/- Above 3.7 kW & upto 7.5 kW,
Rs.9100/- Above 7.5 kW & upto 11.0 kW,
Rs.10150/- Above 11.0 kW & upto 15.0 kW |
| 11.8.1(j)(Temperature rise test at reduced voltage) |
- |
0 |
|
Rs.6250/- for single phase upto 1.5 kW;
For three phase : Rs.6900/- upto 3.7 kW,
Rs.7600/- Above 3.7 kW & upto 7.5 kW,
Rs.9100/- Above 7.5 kW & upto 11.0 kW,
Rs.10150/- Above 11.0 kW & upto 15.0 kW |
| 13.1.1(The pumpset shall be guaranteed for their performance of the nominal volume rate of flow and the nominal head at the guaranteed
duty point. The overall efficiency of the pumpset shall be guaranteed at the declared duty point only.) |
- |
0 |
|
Rs.6250/- for single phase upto 1.5 kW;
For three phase : Rs.6900/- upto 3.7 kW,
Rs.7600/- Above 3.7 kW & upto 7.5 kW,
Rs.9100/- Above 7.5 kW & upto 11.0 kW,
Rs.10150/- Above 11.0 kW & upto 15.0 kW |
| 13.1.2(The guarantee shall be deemed to have been met with, if the measured values of head, volume rate of flow and overall efficiency
are within the limits indicated in clause 8 of IS 11346. However, after applying the tolerance, overall efficiency value shall not be
less than that derived from Fig. 3 to 6.) |
- |
0 |
|
Rs.6250/- for single phase upto 1.5 kW;
For three phase : Rs.6900/- upto 3.7 kW,
Rs.7600/- Above 3.7 kW & upto 7.5 kW,
Rs.9100/- Above 7.5 kW & upto 11.0 kW,
Rs.10150/- Above 11.0 kW & upto 15.0 kW |
| 13.1.3(Monoset motor shall not get overloaded in the specified operating head range at rated voltage and supply frequency.) |
- |
0 |
|
Rs.6250/- for single phase upto 1.5 kW;
For three phase : Rs.6900/- upto 3.7 kW,
Rs.7600/- Above 3.7 kW & upto 7.5 kW,
Rs.9100/- Above 7.5 kW & upto 11.0 kW,
Rs.10150/- Above 11.0 kW & upto 15.0 kW |
| 13.1.4(The tolerance shall apply to guaranteed duty point only.) |
- |
0 |
|
Rs.6250/- for single phase upto 1.5 kW;
For three phase : Rs.6900/- upto 3.7 kW,
Rs.7600/- Above 3.7 kW & upto 7.5 kW,
Rs.9100/- Above 7.5 kW & upto 11.0 kW,
Rs.10150/- Above 11.0 kW & upto 15.0 kW |
| 8.6.5(If four core cable is used, the fourth core is to be used for earthing.) |
- |
0 |
|
Rs.6250/- for single phase upto 1.5 kW;
For three phase : Rs.6900/- upto 3.7 kW,
Rs.7600/- Above 3.7 kW & upto 7.5 kW,
Rs.9100/- Above 7.5 kW & upto 11.0 kW,
Rs.10150/- Above 11.0 kW & upto 15.0 kW |
| 15.1(Marking) |
- |
0 |
|
Rs.6250/- for single phase upto 1.5 kW;
For three phase : Rs.6900/- upto 3.7 kW,
Rs.7600/- Above 3.7 kW & upto 7.5 kW,
Rs.9100/- Above 7.5 kW & upto 11.0 kW,
Rs.10150/- Above 11.0 kW & upto 15.0 kW |
| 15.1(Marking) |
- |
0 |
|
Rs.6250/- for single phase upto 1.5 kW;
For three phase : Rs.6900/- upto 3.7 kW,
Rs.7600/- Above 3.7 kW & upto 7.5 kW,
Rs.9100/- Above 7.5 kW & upto 11.0 kW,
Rs.10150/- Above 11.0 kW & upto 15.0 kW |
| 15.1(Marking) |
- |
0 |
|
Rs.6250/- for single phase upto 1.5 kW;
For three phase : Rs.6900/- upto 3.7 kW,
Rs.7600/- Above 3.7 kW & upto 7.5 kW,
Rs.9100/- Above 7.5 kW & upto 11.0 kW,
Rs.10150/- Above 11.0 kW & upto 15.0 kW |
| 15.1(Marking) |
- |
0 |
|
Rs.6250/- for single phase upto 1.5 kW;
For three phase : Rs.6900/- upto 3.7 kW,
Rs.7600/- Above 3.7 kW & upto 7.5 kW,
Rs.9100/- Above 7.5 kW & upto 11.0 kW,
Rs.10150/- Above 11.0 kW & upto 15.0 kW |
| 15.1(Marking) |
- |
0 |
|
Rs.6250/- for single phase upto 1.5 kW;
For three phase : Rs.6900/- upto 3.7 kW,
Rs.7600/- Above 3.7 kW & upto 7.5 kW,
Rs.9100/- Above 7.5 kW & upto 11.0 kW,
Rs.10150/- Above 11.0 kW & upto 15.0 kW |
| 15.1(Marking) |
- |
0 |
|
Rs.6250/- for single phase upto 1.5 kW;
For three phase : Rs.6900/- upto 3.7 kW,
Rs.7600/- Above 3.7 kW & upto 7.5 kW,
Rs.9100/- Above 7.5 kW & upto 11.0 kW,
Rs.10150/- Above 11.0 kW & upto 15.0 kW |
| 15.1(Marking) |
- |
0 |
|
Rs.6250/- for single phase upto 1.5 kW;
For three phase : Rs.6900/- upto 3.7 kW,
Rs.7600/- Above 3.7 kW & upto 7.5 kW,
Rs.9100/- Above 7.5 kW & upto 11.0 kW,
Rs.10150/- Above 11.0 kW & upto 15.0 kW |
| 15.1(Marking) |
- |
0 |
|
Rs.6250/- for single phase upto 1.5 kW;
For three phase : Rs.6900/- upto 3.7 kW,
Rs.7600/- Above 3.7 kW & upto 7.5 kW,
Rs.9100/- Above 7.5 kW & upto 11.0 kW,
Rs.10150/- Above 11.0 kW & upto 15.0 kW |
| 15.1(Marking) |
- |
0 |
|
Rs.6250/- for single phase upto 1.5 kW;
For three phase : Rs.6900/- upto 3.7 kW,
Rs.7600/- Above 3.7 kW & upto 7.5 kW,
Rs.9100/- Above 7.5 kW & upto 11.0 kW,
Rs.10150/- Above 11.0 kW & upto 15.0 kW |
| 15.1(Marking) |
- |
0 |
|
Rs.6250/- for single phase upto 1.5 kW;
For three phase : Rs.6900/- upto 3.7 kW,
Rs.7600/- Above 3.7 kW & upto 7.5 kW,
Rs.9100/- Above 7.5 kW & upto 11.0 kW,
Rs.10150/- Above 11.0 kW & upto 15.0 kW |
| 15.1(Marking) |
- |
0 |
|
Rs.6250/- for single phase upto 1.5 kW;
For three phase : Rs.6900/- upto 3.7 kW,
Rs.7600/- Above 3.7 kW & upto 7.5 kW,
Rs.9100/- Above 7.5 kW & upto 11.0 kW,
Rs.10150/- Above 11.0 kW & upto 15.0 kW |
| 15.1(Marking) |
- |
0 |
|
Rs.6250/- for single phase upto 1.5 kW;
For three phase : Rs.6900/- upto 3.7 kW,
Rs.7600/- Above 3.7 kW & upto 7.5 kW,
Rs.9100/- Above 7.5 kW & upto 11.0 kW,
Rs.10150/- Above 11.0 kW & upto 15.0 kW |
| 15.1(Marking) |
- |
0 |
|
Rs.6250/- for single phase upto 1.5 kW;
For three phase : Rs.6900/- upto 3.7 kW,
Rs.7600/- Above 3.7 kW & upto 7.5 kW,
Rs.9100/- Above 7.5 kW & upto 11.0 kW,
Rs.10150/- Above 11.0 kW & upto 15.0 kW |
| 15.1(Marking) |
- |
0 |
|
Rs.6250/- for single phase upto 1.5 kW;
For three phase : Rs.6900/- upto 3.7 kW,
Rs.7600/- Above 3.7 kW & upto 7.5 kW,
Rs.9100/- Above 7.5 kW & upto 11.0 kW,
Rs.10150/- Above 11.0 kW & upto 15.0 kW |
| 15.1(Marking) |
- |
0 |
|
Rs.6250/- for single phase upto 1.5 kW;
For three phase : Rs.6900/- upto 3.7 kW,
Rs.7600/- Above 3.7 kW & upto 7.5 kW,
Rs.9100/- Above 7.5 kW & upto 11.0 kW,
Rs.10150/- Above 11.0 kW & upto 15.0 kW |
| 15.1(Marking) |
- |
0 |
|
Rs.6250/- for single phase upto 1.5 kW;
For three phase : Rs.6900/- upto 3.7 kW,
Rs.7600/- Above 3.7 kW & upto 7.5 kW,
Rs.9100/- Above 7.5 kW & upto 11.0 kW,
Rs.10150/- Above 11.0 kW & upto 15.0 kW |
| 15.1(Marking) |
- |
0 |
|
Rs.6250/- for single phase upto 1.5 kW;
For three phase : Rs.6900/- upto 3.7 kW,
Rs.7600/- Above 3.7 kW & upto 7.5 kW,
Rs.9100/- Above 7.5 kW & upto 11.0 kW,
Rs.10150/- Above 11.0 kW & upto 15.0 kW |
| 15.1(Marking) |
- |
0 |
|
Rs.6250/- for single phase upto 1.5 kW;
For three phase : Rs.6900/- upto 3.7 kW,
Rs.7600/- Above 3.7 kW & upto 7.5 kW,
Rs.9100/- Above 7.5 kW & upto 11.0 kW,
Rs.10150/- Above 11.0 kW & upto 15.0 kW |
| 15.1(Hydrostatic Pressure Test) |
- |
0 |
|
Rs.6250/- for single phase upto 1.5 kW;
For three phase : Rs.6900/- upto 3.7 kW,
Rs.7600/- Above 3.7 kW & upto 7.5 kW,
Rs.9100/- Above 7.5 kW & upto 11.0 kW,
Rs.10150/- Above 11.0 kW & upto 15.0 kW |
| 13.5(Minimum Current Requirement) |
- |
0 |
|
Rs.6250/- for single phase upto 1.5 kW;
For three phase : Rs.6900/- upto 3.7 kW,
Rs.7600/- Above 3.7 kW & upto 7.5 kW,
Rs.9100/- Above 7.5 kW & upto 11.0 kW,
Rs.10150/- Above 11.0 kW & upto 15.0 kW |
| 11.1.1(Type of Enclosures) |
- |
4000 |
|
Rs.6250/- for single phase upto 1.5 kW;
For three phase : Rs.6900/- upto 3.7 kW,
Rs.7600/- Above 3.7 kW & upto 7.5 kW,
Rs.9100/- Above 7.5 kW & upto 11.0 kW,
Rs.10150/- Above 11.0 kW & upto 15.0 kW |
| 12.2(Laboratory Test) |
- |
0 |
|
Rs.6250/- for single phase upto 1.5 kW;
For three phase : Rs.6900/- upto 3.7 kW,
Rs.7600/- Above 3.7 kW & upto 7.5 kW,
Rs.9100/- Above 7.5 kW & upto 11.0 kW,
Rs.10150/- Above 11.0 kW & upto 15.0 kW |
| 13(Guarantee and tolerance on pump performance) |
- |
0 |
|
Rs.6250/- for single phase upto 1.5 kW;
For three phase : Rs.6900/- upto 3.7 kW,
Rs.7600/- Above 3.7 kW & upto 7.5 kW,
Rs.9100/- Above 7.5 kW & upto 11.0 kW,
Rs.10150/- Above 11.0 kW & upto 15.0 kW |
| 13.4.1 (Amendment-1)(Pump Efficiency) |
- |
0 |
|
Rs.6250/- for single phase upto 1.5 kW;
For three phase : Rs.6900/- upto 3.7 kW,
Rs.7600/- Above 3.7 kW & upto 7.5 kW,
Rs.9100/- Above 7.5 kW & upto 11.0 kW,
Rs.10150/- Above 11.0 kW & upto 15.0 kW |
|
28 Oct, 2028 |
- - |
| 12 |
IS 14220 (2018) |
Openwell submersible pumpsets - Specification (First Revision) |
- |
8650 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 8.1(Design Features) |
- |
0 |
|
Rs.8650/-3.7kW
Rs.9350/-3.7kWto7.5kW
Rs.10600/-7.5kWto11kW
Rs.13250/-11kW to15kW
Rs.18100/-15 kWto20kW
Rs.20950/-20kWto25kW
Rs.23800/-25kW to 30kW
Rs.26600/- 30kWto35kW
Rs.30150/-35kWto40kW
Rs.31400/-40kWto45kW
Rs.34000/-45kWto50kW |
| 8.1.1(Design Features) |
- |
0 |
|
Rs.8650/-3.7kW
Rs.9350/-3.7kWto7.5kW
Rs.10600/-7.5kWto11kW
Rs.13250/-11kW to15kW
Rs.18100/-15 kWto20kW
Rs.20950/-20kWto25kW
Rs.23800/-25kW to 30kW
Rs.26600/- 30kWto35kW
Rs.30150/-35kWto40kW
Rs.31400/-40kWto45kW
Rs.34000/-45kWto50kW |
| 8.1.4(Design Features) |
- |
0 |
|
Rs.8650/-3.7kW
Rs.9350/-3.7kWto7.5kW
Rs.10600/-7.5kWto11kW
Rs.13250/-11kW to15kW
Rs.18100/-15 kWto20kW
Rs.20950/-20kWto25kW
Rs.23800/-25kW to 30kW
Rs.26600/- 30kWto35kW
Rs.30150/-35kWto40kW
Rs.31400/-40kWto45kW
Rs.34000/-45kWto50kW |
| 8.1.5(Design Features) |
- |
0 |
|
Rs.8650/-3.7kW
Rs.9350/-3.7kWto7.5kW
Rs.10600/-7.5kWto11kW
Rs.13250/-11kW to15kW
Rs.18100/-15 kWto20kW
Rs.20950/-20kWto25kW
Rs.23800/-25kW to 30kW
Rs.26600/- 30kWto35kW
Rs.30150/-35kWto40kW
Rs.31400/-40kWto45kW
Rs.34000/-45kWto50kW |
| 8.1.5(Design Features) |
- |
0 |
|
Rs.8650/-3.7kW
Rs.9350/-3.7kWto7.5kW
Rs.10600/-7.5kWto11kW
Rs.13250/-11kW to15kW
Rs.18100/-15 kWto20kW
Rs.20950/-20kWto25kW
Rs.23800/-25kW to 30kW
Rs.26600/- 30kWto35kW
Rs.30150/-35kWto40kW
Rs.31400/-40kWto45kW
Rs.34000/-45kWto50kW |
| 8.1.7(Design Features) |
- |
0 |
|
Rs.8650/-3.7kW
Rs.9350/-3.7kWto7.5kW
Rs.10600/-7.5kWto11kW
Rs.13250/-11kW to15kW
Rs.18100/-15 kWto20kW
Rs.20950/-20kWto25kW
Rs.23800/-25kW to 30kW
Rs.26600/- 30kWto35kW
Rs.30150/-35kWto40kW
Rs.31400/-40kWto45kW
Rs.34000/-45kWto50kW |
| 9(Efficiency) |
- |
0 |
|
Rs.8650/-3.7kW
Rs.9350/-3.7kWto7.5kW
Rs.10600/-7.5kWto11kW
Rs.13250/-11kW to15kW
Rs.18100/-15 kWto20kW
Rs.20950/-20kWto25kW
Rs.23800/-25kW to 30kW
Rs.26600/- 30kWto35kW
Rs.30150/-35kWto40kW
Rs.31400/-40kWto45kW
Rs.34000/-45kWto50kW |
| 10(Performance
(Cl 17.1 of IS 5120)) |
- |
0 |
|
Rs.8650/-3.7kW
Rs.9350/-3.7kWto7.5kW
Rs.10600/-7.5kWto11kW
Rs.13250/-11kW to15kW
Rs.18100/-15 kWto20kW
Rs.20950/-20kWto25kW
Rs.23800/-25kW to 30kW
Rs.26600/- 30kWto35kW
Rs.30150/-35kWto40kW
Rs.31400/-40kWto45kW
Rs.34000/-45kWto50kW |
| 10(Suction and Delivery Ends
(Cl 17.2 of IS 5120)) |
- |
0 |
|
Rs.8650/-3.7kW
Rs.9350/-3.7kWto7.5kW
Rs.10600/-7.5kWto11kW
Rs.13250/-11kW to15kW
Rs.18100/-15 kWto20kW
Rs.20950/-20kWto25kW
Rs.23800/-25kW to 30kW
Rs.26600/- 30kWto35kW
Rs.30150/-35kWto40kW
Rs.31400/-40kWto45kW
Rs.34000/-45kWto50kW |
| 10(Suction and Delivery Ends
(Cl 17.2.1 of IS 5120)) |
- |
0 |
|
Rs.8650/-3.7kW
Rs.9350/-3.7kWto7.5kW
Rs.10600/-7.5kWto11kW
Rs.13250/-11kW to15kW
Rs.18100/-15 kWto20kW
Rs.20950/-20kWto25kW
Rs.23800/-25kW to 30kW
Rs.26600/- 30kWto35kW
Rs.30150/-35kWto40kW
Rs.31400/-40kWto45kW
Rs.34000/-45kWto50kW |
| 10(Fluid Passages
(Cl 17.3 of IS 5120)) |
- |
0 |
|
Rs.8650/-3.7kW
Rs.9350/-3.7kWto7.5kW
Rs.10600/-7.5kWto11kW
Rs.13250/-11kW to15kW
Rs.18100/-15 kWto20kW
Rs.20950/-20kWto25kW
Rs.23800/-25kW to 30kW
Rs.26600/- 30kWto35kW
Rs.30150/-35kWto40kW
Rs.31400/-40kWto45kW
Rs.34000/-45kWto50kW |
| 10(Draining Plugrs
(Cl 17.4 of IS 5120)) |
- |
0 |
|
Rs.8650/-3.7kW
Rs.9350/-3.7kWto7.5kW
Rs.10600/-7.5kWto11kW
Rs.13250/-11kW to15kW
Rs.18100/-15 kWto20kW
Rs.20950/-20kWto25kW
Rs.23800/-25kW to 30kW
Rs.26600/- 30kWto35kW
Rs.30150/-35kWto40kW
Rs.31400/-40kWto45kW
Rs.34000/-45kWto50kW |
| 10(Lantern Ring
(Cl 17.5 of IS 5120)) |
- |
0 |
|
Rs.8650/-3.7kW
Rs.9350/-3.7kWto7.5kW
Rs.10600/-7.5kWto11kW
Rs.13250/-11kW to15kW
Rs.18100/-15 kWto20kW
Rs.20950/-20kWto25kW
Rs.23800/-25kW to 30kW
Rs.26600/- 30kWto35kW
Rs.30150/-35kWto40kW
Rs.31400/-40kWto45kW
Rs.34000/-45kWto50kW |
| 10(Casing
(Cl 17.6 of IS 5120)) |
- |
0 |
|
Rs.8650/-3.7kW
Rs.9350/-3.7kWto7.5kW
Rs.10600/-7.5kWto11kW
Rs.13250/-11kW to15kW
Rs.18100/-15 kWto20kW
Rs.20950/-20kWto25kW
Rs.23800/-25kW to 30kW
Rs.26600/- 30kWto35kW
Rs.30150/-35kWto40kW
Rs.31400/-40kWto45kW
Rs.34000/-45kWto50kW |
| 10(Impeller
(Cl 17.7 of IS 5120)) |
- |
0 |
|
Rs.8650/-3.7kW
Rs.9350/-3.7kWto7.5kW
Rs.10600/-7.5kWto11kW
Rs.13250/-11kW to15kW
Rs.18100/-15 kWto20kW
Rs.20950/-20kWto25kW
Rs.23800/-25kW to 30kW
Rs.26600/- 30kWto35kW
Rs.30150/-35kWto40kW
Rs.31400/-40kWto45kW
Rs.34000/-45kWto50kW |
| 10(Shaft
(Cl 17.8 of IS 5120)) |
- |
0 |
|
Rs.8650/-3.7kW
Rs.9350/-3.7kWto7.5kW
Rs.10600/-7.5kWto11kW
Rs.13250/-11kW to15kW
Rs.18100/-15 kWto20kW
Rs.20950/-20kWto25kW
Rs.23800/-25kW to 30kW
Rs.26600/- 30kWto35kW
Rs.30150/-35kWto40kW
Rs.31400/-40kWto45kW
Rs.34000/-45kWto50kW |
| 10(Shaft Couplings
(Cl 17.9 of IS 5120)) |
- |
0 |
|
Rs.8650/-3.7kW
Rs.9350/-3.7kWto7.5kW
Rs.10600/-7.5kWto11kW
Rs.13250/-11kW to15kW
Rs.18100/-15 kWto20kW
Rs.20950/-20kWto25kW
Rs.23800/-25kW to 30kW
Rs.26600/- 30kWto35kW
Rs.30150/-35kWto40kW
Rs.31400/-40kWto45kW
Rs.34000/-45kWto50kW |
| 10(Bearings
(Cl 17.10 of IS 5120)) |
- |
0 |
|
Rs.8650/-3.7kW
Rs.9350/-3.7kWto7.5kW
Rs.10600/-7.5kWto11kW
Rs.13250/-11kW to15kW
Rs.18100/-15 kWto20kW
Rs.20950/-20kWto25kW
Rs.23800/-25kW to 30kW
Rs.26600/- 30kWto35kW
Rs.30150/-35kWto40kW
Rs.31400/-40kWto45kW
Rs.34000/-45kWto50kW |
| 10(Bearings
(Cl 17.10.1 of IS 5120)) |
- |
0 |
|
Rs.8650/-3.7kW
Rs.9350/-3.7kWto7.5kW
Rs.10600/-7.5kWto11kW
Rs.13250/-11kW to15kW
Rs.18100/-15 kWto20kW
Rs.20950/-20kWto25kW
Rs.23800/-25kW to 30kW
Rs.26600/- 30kWto35kW
Rs.30150/-35kWto40kW
Rs.31400/-40kWto45kW
Rs.34000/-45kWto50kW |
| 10(Bearings
(Cl 17.10.2 of IS 5120)) |
- |
0 |
|
Rs.8650/-3.7kW
Rs.9350/-3.7kWto7.5kW
Rs.10600/-7.5kWto11kW
Rs.13250/-11kW to15kW
Rs.18100/-15 kWto20kW
Rs.20950/-20kWto25kW
Rs.23800/-25kW to 30kW
Rs.26600/- 30kWto35kW
Rs.30150/-35kWto40kW
Rs.31400/-40kWto45kW
Rs.34000/-45kWto50kW |
| 10( Stuffing Boxes
(Cl 17.11 of IS 5120)) |
- |
0 |
|
Rs.8650/-3.7kW
Rs.9350/-3.7kWto7.5kW
Rs.10600/-7.5kWto11kW
Rs.13250/-11kW to15kW
Rs.18100/-15 kWto20kW
Rs.20950/-20kWto25kW
Rs.23800/-25kW to 30kW
Rs.26600/- 30kWto35kW
Rs.30150/-35kWto40kW
Rs.31400/-40kWto45kW
Rs.34000/-45kWto50kW |
| 10(Base Plates
(Cl 17.12 of IS 5120)) |
- |
0 |
|
Rs.8650/-3.7kW
Rs.9350/-3.7kWto7.5kW
Rs.10600/-7.5kWto11kW
Rs.13250/-11kW to15kW
Rs.18100/-15 kWto20kW
Rs.20950/-20kWto25kW
Rs.23800/-25kW to 30kW
Rs.26600/- 30kWto35kW
Rs.30150/-35kWto40kW
Rs.31400/-40kWto45kW
Rs.34000/-45kWto50kW |
| 10(Prime Mover
(Cl 17.13 of IS 5120)) |
- |
0 |
|
Rs.8650/-3.7kW
Rs.9350/-3.7kWto7.5kW
Rs.10600/-7.5kWto11kW
Rs.13250/-11kW to15kW
Rs.18100/-15 kWto20kW
Rs.20950/-20kWto25kW
Rs.23800/-25kW to 30kW
Rs.26600/- 30kWto35kW
Rs.30150/-35kWto40kW
Rs.31400/-40kWto45kW
Rs.34000/-45kWto50kW |
| 10(Name Plate
(Cl 17.14 of IS 5120)) |
- |
0 |
|
Rs.8650/-3.7kW
Rs.9350/-3.7kWto7.5kW
Rs.10600/-7.5kWto11kW
Rs.13250/-11kW to15kW
Rs.18100/-15 kWto20kW
Rs.20950/-20kWto25kW
Rs.23800/-25kW to 30kW
Rs.26600/- 30kWto35kW
Rs.30150/-35kWto40kW
Rs.31400/-40kWto45kW
Rs.34000/-45kWto50kW |
| 10(Name Plate
(Cl 17.14 of IS 5120)) |
- |
0 |
|
Rs.8650/-3.7kW
Rs.9350/-3.7kWto7.5kW
Rs.10600/-7.5kWto11kW
Rs.13250/-11kW to15kW
Rs.18100/-15 kWto20kW
Rs.20950/-20kWto25kW
Rs.23800/-25kW to 30kW
Rs.26600/- 30kWto35kW
Rs.30150/-35kWto40kW
Rs.31400/-40kWto45kW
Rs.34000/-45kWto50kW |
| 10(Name Plate
(Cl 17.14 of IS 5120)) |
- |
0 |
|
Rs.8650/-3.7kW
Rs.9350/-3.7kWto7.5kW
Rs.10600/-7.5kWto11kW
Rs.13250/-11kW to15kW
Rs.18100/-15 kWto20kW
Rs.20950/-20kWto25kW
Rs.23800/-25kW to 30kW
Rs.26600/- 30kWto35kW
Rs.30150/-35kWto40kW
Rs.31400/-40kWto45kW
Rs.34000/-45kWto50kW |
| 10(Name Plate
(Cl 17.14.1 of IS 5120)) |
- |
0 |
|
Rs.8650/-3.7kW
Rs.9350/-3.7kWto7.5kW
Rs.10600/-7.5kWto11kW
Rs.13250/-11kW to15kW
Rs.18100/-15 kWto20kW
Rs.20950/-20kWto25kW
Rs.23800/-25kW to 30kW
Rs.26600/- 30kWto35kW
Rs.30150/-35kWto40kW
Rs.31400/-40kWto45kW
Rs.34000/-45kWto50kW |
| 10.2(Casing) |
- |
0 |
|
Rs.8650/-3.7kW
Rs.9350/-3.7kWto7.5kW
Rs.10600/-7.5kWto11kW
Rs.13250/-11kW to15kW
Rs.18100/-15 kWto20kW
Rs.20950/-20kWto25kW
Rs.23800/-25kW to 30kW
Rs.26600/- 30kWto35kW
Rs.30150/-35kWto40kW
Rs.31400/-40kWto45kW
Rs.34000/-45kWto50kW |
| 10.3(Impeller) |
- |
0 |
|
Rs.8650/-3.7kW
Rs.9350/-3.7kWto7.5kW
Rs.10600/-7.5kWto11kW
Rs.13250/-11kW to15kW
Rs.18100/-15 kWto20kW
Rs.20950/-20kWto25kW
Rs.23800/-25kW to 30kW
Rs.26600/- 30kWto35kW
Rs.30150/-35kWto40kW
Rs.31400/-40kWto45kW
Rs.34000/-45kWto50kW |
| 10.4.1(Shaft) |
- |
0 |
|
Rs.8650/-3.7kW
Rs.9350/-3.7kWto7.5kW
Rs.10600/-7.5kWto11kW
Rs.13250/-11kW to15kW
Rs.18100/-15 kWto20kW
Rs.20950/-20kWto25kW
Rs.23800/-25kW to 30kW
Rs.26600/- 30kWto35kW
Rs.30150/-35kWto40kW
Rs.31400/-40kWto45kW
Rs.34000/-45kWto50kW |
| 10.4.2(Shaft) |
- |
0 |
|
Rs.8650/-3.7kW
Rs.9350/-3.7kWto7.5kW
Rs.10600/-7.5kWto11kW
Rs.13250/-11kW to15kW
Rs.18100/-15 kWto20kW
Rs.20950/-20kWto25kW
Rs.23800/-25kW to 30kW
Rs.26600/- 30kWto35kW
Rs.30150/-35kWto40kW
Rs.31400/-40kWto45kW
Rs.34000/-45kWto50kW |
| 10.5.1(Balancing) |
- |
0 |
|
Rs.8650/-3.7kW
Rs.9350/-3.7kWto7.5kW
Rs.10600/-7.5kWto11kW
Rs.13250/-11kW to15kW
Rs.18100/-15 kWto20kW
Rs.20950/-20kWto25kW
Rs.23800/-25kW to 30kW
Rs.26600/- 30kWto35kW
Rs.30150/-35kWto40kW
Rs.31400/-40kWto45kW
Rs.34000/-45kWto50kW |
| 10.5.2(Balancing) |
- |
0 |
|
Rs.8650/-3.7kW
Rs.9350/-3.7kWto7.5kW
Rs.10600/-7.5kWto11kW
Rs.13250/-11kW to15kW
Rs.18100/-15 kWto20kW
Rs.20950/-20kWto25kW
Rs.23800/-25kW to 30kW
Rs.26600/- 30kWto35kW
Rs.30150/-35kWto40kW
Rs.31400/-40kWto45kW
Rs.34000/-45kWto50kW |
| 10.5.3(Balancing) |
- |
0 |
|
Rs.8650/-3.7kW
Rs.9350/-3.7kWto7.5kW
Rs.10600/-7.5kWto11kW
Rs.13250/-11kW to15kW
Rs.18100/-15 kWto20kW
Rs.20950/-20kWto25kW
Rs.23800/-25kW to 30kW
Rs.26600/- 30kWto35kW
Rs.30150/-35kWto40kW
Rs.31400/-40kWto45kW
Rs.34000/-45kWto50kW |
| 10.5.4(Balancing) |
- |
0 |
|
Rs.8650/-3.7kW
Rs.9350/-3.7kWto7.5kW
Rs.10600/-7.5kWto11kW
Rs.13250/-11kW to15kW
Rs.18100/-15 kWto20kW
Rs.20950/-20kWto25kW
Rs.23800/-25kW to 30kW
Rs.26600/- 30kWto35kW
Rs.30150/-35kWto40kW
Rs.31400/-40kWto45kW
Rs.34000/-45kWto50kW |
| 10.6.1( Provision for Earthing) |
- |
0 |
|
Rs.8650/-3.7kW
Rs.9350/-3.7kWto7.5kW
Rs.10600/-7.5kWto11kW
Rs.13250/-11kW to15kW
Rs.18100/-15 kWto20kW
Rs.20950/-20kWto25kW
Rs.23800/-25kW to 30kW
Rs.26600/- 30kWto35kW
Rs.30150/-35kWto40kW
Rs.31400/-40kWto45kW
Rs.34000/-45kWto50kW |
| 10.6.2( Provision for Earthing) |
- |
0 |
|
Rs.8650/-3.7kW
Rs.9350/-3.7kWto7.5kW
Rs.10600/-7.5kWto11kW
Rs.13250/-11kW to15kW
Rs.18100/-15 kWto20kW
Rs.20950/-20kWto25kW
Rs.23800/-25kW to 30kW
Rs.26600/- 30kWto35kW
Rs.30150/-35kWto40kW
Rs.31400/-40kWto45kW
Rs.34000/-45kWto50kW |
| 10.6.3( Provision for Earthing) |
- |
0 |
|
Rs.8650/-3.7kW
Rs.9350/-3.7kWto7.5kW
Rs.10600/-7.5kWto11kW
Rs.13250/-11kW to15kW
Rs.18100/-15 kWto20kW
Rs.20950/-20kWto25kW
Rs.23800/-25kW to 30kW
Rs.26600/- 30kWto35kW
Rs.30150/-35kWto40kW
Rs.31400/-40kWto45kW
Rs.34000/-45kWto50kW |
| 10.6.4( Provision for Earthing) |
- |
0 |
|
Rs.8650/-3.7kW
Rs.9350/-3.7kWto7.5kW
Rs.10600/-7.5kWto11kW
Rs.13250/-11kW to15kW
Rs.18100/-15 kWto20kW
Rs.20950/-20kWto25kW
Rs.23800/-25kW to 30kW
Rs.26600/- 30kWto35kW
Rs.30150/-35kWto40kW
Rs.31400/-40kWto45kW
Rs.34000/-45kWto50kW |
| 10.7.1(Terminal Marking and Direction of Rotation) |
- |
0 |
|
Rs.8650/-3.7kW
Rs.9350/-3.7kWto7.5kW
Rs.10600/-7.5kWto11kW
Rs.13250/-11kW to15kW
Rs.18100/-15 kWto20kW
Rs.20950/-20kWto25kW
Rs.23800/-25kW to 30kW
Rs.26600/- 30kWto35kW
Rs.30150/-35kWto40kW
Rs.31400/-40kWto45kW
Rs.34000/-45kWto50kW |
| 10.7.2(Terminal Marking and Direction of Rotation) |
- |
0 |
|
Rs.8650/-3.7kW
Rs.9350/-3.7kWto7.5kW
Rs.10600/-7.5kWto11kW
Rs.13250/-11kW to15kW
Rs.18100/-15 kWto20kW
Rs.20950/-20kWto25kW
Rs.23800/-25kW to 30kW
Rs.26600/- 30kWto35kW
Rs.30150/-35kWto40kW
Rs.31400/-40kWto45kW
Rs.34000/-45kWto50kW |
| 10.7.3(Terminal Marking and Direction of Rotation) |
- |
0 |
|
Rs.8650/-3.7kW
Rs.9350/-3.7kWto7.5kW
Rs.10600/-7.5kWto11kW
Rs.13250/-11kW to15kW
Rs.18100/-15 kWto20kW
Rs.20950/-20kWto25kW
Rs.23800/-25kW to 30kW
Rs.26600/- 30kWto35kW
Rs.30150/-35kWto40kW
Rs.31400/-40kWto45kW
Rs.34000/-45kWto50kW |
| 15.5(Hydrostatic Pressure Test) |
- |
0 |
|
Rs.8650/-3.7kW
Rs.9350/-3.7kWto7.5kW
Rs.10600/-7.5kWto11kW
Rs.13250/-11kW to15kW
Rs.18100/-15 kWto20kW
Rs.20950/-20kWto25kW
Rs.23800/-25kW to 30kW
Rs.26600/- 30kWto35kW
Rs.30150/-35kWto40kW
Rs.31400/-40kWto45kW
Rs.34000/-45kWto50kW |
| 15.2(Laboratory Tests
Cl.8 of IS 11346-2002
Rate of flow and head
Cl.8 of IS 11346-2002) |
- |
0 |
|
Rs.8650/-3.7kW
Rs.9350/-3.7kWto7.5kW
Rs.10600/-7.5kWto11kW
Rs.13250/-11kW to15kW
Rs.18100/-15 kWto20kW
Rs.20950/-20kWto25kW
Rs.23800/-25kW to 30kW
Rs.26600/- 30kWto35kW
Rs.30150/-35kWto40kW
Rs.31400/-40kWto45kW
Rs.34000/-45kWto50kW |
| 15.2(Laboratory Tests
Cl.8 of IS 11346-2002
Efficiency
Cl.8.3 of IS 11346-2002) |
- |
0 |
|
Rs.8650/-3.7kW
Rs.9350/-3.7kWto7.5kW
Rs.10600/-7.5kWto11kW
Rs.13250/-11kW to15kW
Rs.18100/-15 kWto20kW
Rs.20950/-20kWto25kW
Rs.23800/-25kW to 30kW
Rs.26600/- 30kWto35kW
Rs.30150/-35kWto40kW
Rs.31400/-40kWto45kW
Rs.34000/-45kWto50kW |
| 16.1.1( Guarantee of Performance) |
- |
0 |
|
Rs.8650/-3.7kW
Rs.9350/-3.7kWto7.5kW
Rs.10600/-7.5kWto11kW
Rs.13250/-11kW to15kW
Rs.18100/-15 kWto20kW
Rs.20950/-20kWto25kW
Rs.23800/-25kW to 30kW
Rs.26600/- 30kWto35kW
Rs.30150/-35kWto40kW
Rs.31400/-40kWto45kW
Rs.34000/-45kWto50kW |
| 16.1.2( Guarantee of Performance) |
- |
0 |
|
Rs.8650/-3.7kW
Rs.9350/-3.7kWto7.5kW
Rs.10600/-7.5kWto11kW
Rs.13250/-11kW to15kW
Rs.18100/-15 kWto20kW
Rs.20950/-20kWto25kW
Rs.23800/-25kW to 30kW
Rs.26600/- 30kWto35kW
Rs.30150/-35kWto40kW
Rs.31400/-40kWto45kW
Rs.34000/-45kWto50kW |
| 16.1.3( Guarantee of Performance) |
- |
0 |
|
Rs.8650/-3.7kW
Rs.9350/-3.7kWto7.5kW
Rs.10600/-7.5kWto11kW
Rs.13250/-11kW to15kW
Rs.18100/-15 kWto20kW
Rs.20950/-20kWto25kW
Rs.23800/-25kW to 30kW
Rs.26600/- 30kWto35kW
Rs.30150/-35kWto40kW
Rs.31400/-40kWto45kW
Rs.34000/-45kWto50kW |
| 16.1.4( Guarantee of Performance) |
- |
0 |
|
Rs.8650/-3.7kW
Rs.9350/-3.7kWto7.5kW
Rs.10600/-7.5kWto11kW
Rs.13250/-11kW to15kW
Rs.18100/-15 kWto20kW
Rs.20950/-20kWto25kW
Rs.23800/-25kW to 30kW
Rs.26600/- 30kWto35kW
Rs.30150/-35kWto40kW
Rs.31400/-40kWto45kW
Rs.34000/-45kWto50kW |
| 16.1.5( Guarantee of Performance) |
- |
0 |
|
Rs.8650/-3.7kW
Rs.9350/-3.7kWto7.5kW
Rs.10600/-7.5kWto11kW
Rs.13250/-11kW to15kW
Rs.18100/-15 kWto20kW
Rs.20950/-20kWto25kW
Rs.23800/-25kW to 30kW
Rs.26600/- 30kWto35kW
Rs.30150/-35kWto40kW
Rs.31400/-40kWto45kW
Rs.34000/-45kWto50kW |
| 18.1(Marking) |
- |
0 |
|
Rs.8650/-3.7kW
Rs.9350/-3.7kWto7.5kW
Rs.10600/-7.5kWto11kW
Rs.13250/-11kW to15kW
Rs.18100/-15 kWto20kW
Rs.20950/-20kWto25kW
Rs.23800/-25kW to 30kW
Rs.26600/- 30kWto35kW
Rs.30150/-35kWto40kW
Rs.31400/-40kWto45kW
Rs.34000/-45kWto50kW |
| 18.1(Marking) |
- |
0 |
|
Rs.8650/-3.7kW
Rs.9350/-3.7kWto7.5kW
Rs.10600/-7.5kWto11kW
Rs.13250/-11kW to15kW
Rs.18100/-15 kWto20kW
Rs.20950/-20kWto25kW
Rs.23800/-25kW to 30kW
Rs.26600/- 30kWto35kW
Rs.30150/-35kWto40kW
Rs.31400/-40kWto45kW
Rs.34000/-45kWto50kW |
| 18.1(Marking) |
- |
0 |
|
Rs.8650/-3.7kW
Rs.9350/-3.7kWto7.5kW
Rs.10600/-7.5kWto11kW
Rs.13250/-11kW to15kW
Rs.18100/-15 kWto20kW
Rs.20950/-20kWto25kW
Rs.23800/-25kW to 30kW
Rs.26600/- 30kWto35kW
Rs.30150/-35kWto40kW
Rs.31400/-40kWto45kW
Rs.34000/-45kWto50kW |
| 18.1(Marking) |
- |
0 |
|
Rs.8650/-3.7kW
Rs.9350/-3.7kWto7.5kW
Rs.10600/-7.5kWto11kW
Rs.13250/-11kW to15kW
Rs.18100/-15 kWto20kW
Rs.20950/-20kWto25kW
Rs.23800/-25kW to 30kW
Rs.26600/- 30kWto35kW
Rs.30150/-35kWto40kW
Rs.31400/-40kWto45kW
Rs.34000/-45kWto50kW |
| 18.1(Marking) |
- |
0 |
|
Rs.8650/-3.7kW
Rs.9350/-3.7kWto7.5kW
Rs.10600/-7.5kWto11kW
Rs.13250/-11kW to15kW
Rs.18100/-15 kWto20kW
Rs.20950/-20kWto25kW
Rs.23800/-25kW to 30kW
Rs.26600/- 30kWto35kW
Rs.30150/-35kWto40kW
Rs.31400/-40kWto45kW
Rs.34000/-45kWto50kW |
| 18.1(Marking) |
- |
0 |
|
Rs.8650/-3.7kW
Rs.9350/-3.7kWto7.5kW
Rs.10600/-7.5kWto11kW
Rs.13250/-11kW to15kW
Rs.18100/-15 kWto20kW
Rs.20950/-20kWto25kW
Rs.23800/-25kW to 30kW
Rs.26600/- 30kWto35kW
Rs.30150/-35kWto40kW
Rs.31400/-40kWto45kW
Rs.34000/-45kWto50kW |
| 18.1(Marking) |
- |
0 |
|
Rs.8650/-3.7kW
Rs.9350/-3.7kWto7.5kW
Rs.10600/-7.5kWto11kW
Rs.13250/-11kW to15kW
Rs.18100/-15 kWto20kW
Rs.20950/-20kWto25kW
Rs.23800/-25kW to 30kW
Rs.26600/- 30kWto35kW
Rs.30150/-35kWto40kW
Rs.31400/-40kWto45kW
Rs.34000/-45kWto50kW |
| 18.1(Marking) |
- |
0 |
|
Rs.8650/-3.7kW
Rs.9350/-3.7kWto7.5kW
Rs.10600/-7.5kWto11kW
Rs.13250/-11kW to15kW
Rs.18100/-15 kWto20kW
Rs.20950/-20kWto25kW
Rs.23800/-25kW to 30kW
Rs.26600/- 30kWto35kW
Rs.30150/-35kWto40kW
Rs.31400/-40kWto45kW
Rs.34000/-45kWto50kW |
| 18.1(Marking) |
- |
0 |
|
Rs.8650/-3.7kW
Rs.9350/-3.7kWto7.5kW
Rs.10600/-7.5kWto11kW
Rs.13250/-11kW to15kW
Rs.18100/-15 kWto20kW
Rs.20950/-20kWto25kW
Rs.23800/-25kW to 30kW
Rs.26600/- 30kWto35kW
Rs.30150/-35kWto40kW
Rs.31400/-40kWto45kW
Rs.34000/-45kWto50kW |
| 18.1(Marking) |
- |
0 |
|
Rs.8650/-3.7kW
Rs.9350/-3.7kWto7.5kW
Rs.10600/-7.5kWto11kW
Rs.13250/-11kW to15kW
Rs.18100/-15 kWto20kW
Rs.20950/-20kWto25kW
Rs.23800/-25kW to 30kW
Rs.26600/- 30kWto35kW
Rs.30150/-35kWto40kW
Rs.31400/-40kWto45kW
Rs.34000/-45kWto50kW |
| 18.1(Marking) |
- |
0 |
|
Rs.8650/-3.7kW
Rs.9350/-3.7kWto7.5kW
Rs.10600/-7.5kWto11kW
Rs.13250/-11kW to15kW
Rs.18100/-15 kWto20kW
Rs.20950/-20kWto25kW
Rs.23800/-25kW to 30kW
Rs.26600/- 30kWto35kW
Rs.30150/-35kWto40kW
Rs.31400/-40kWto45kW
Rs.34000/-45kWto50kW |
| 18.1(Marking) |
- |
0 |
|
Rs.8650/-3.7kW
Rs.9350/-3.7kWto7.5kW
Rs.10600/-7.5kWto11kW
Rs.13250/-11kW to15kW
Rs.18100/-15 kWto20kW
Rs.20950/-20kWto25kW
Rs.23800/-25kW to 30kW
Rs.26600/- 30kWto35kW
Rs.30150/-35kWto40kW
Rs.31400/-40kWto45kW
Rs.34000/-45kWto50kW |
| 18.1(Marking) |
- |
0 |
|
Rs.8650/-3.7kW
Rs.9350/-3.7kWto7.5kW
Rs.10600/-7.5kWto11kW
Rs.13250/-11kW to15kW
Rs.18100/-15 kWto20kW
Rs.20950/-20kWto25kW
Rs.23800/-25kW to 30kW
Rs.26600/- 30kWto35kW
Rs.30150/-35kWto40kW
Rs.31400/-40kWto45kW
Rs.34000/-45kWto50kW |
| 18.1(Marking) |
- |
0 |
|
Rs.8650/-3.7kW
Rs.9350/-3.7kWto7.5kW
Rs.10600/-7.5kWto11kW
Rs.13250/-11kW to15kW
Rs.18100/-15 kWto20kW
Rs.20950/-20kWto25kW
Rs.23800/-25kW to 30kW
Rs.26600/- 30kWto35kW
Rs.30150/-35kWto40kW
Rs.31400/-40kWto45kW
Rs.34000/-45kWto50kW |
| 18.1(Marking) |
- |
0 |
|
Rs.8650/-3.7kW
Rs.9350/-3.7kWto7.5kW
Rs.10600/-7.5kWto11kW
Rs.13250/-11kW to15kW
Rs.18100/-15 kWto20kW
Rs.20950/-20kWto25kW
Rs.23800/-25kW to 30kW
Rs.26600/- 30kWto35kW
Rs.30150/-35kWto40kW
Rs.31400/-40kWto45kW
Rs.34000/-45kWto50kW |
| 18.1(Marking) |
- |
0 |
|
Rs.8650/-3.7kW
Rs.9350/-3.7kWto7.5kW
Rs.10600/-7.5kWto11kW
Rs.13250/-11kW to15kW
Rs.18100/-15 kWto20kW
Rs.20950/-20kWto25kW
Rs.23800/-25kW to 30kW
Rs.26600/- 30kWto35kW
Rs.30150/-35kWto40kW
Rs.31400/-40kWto45kW
Rs.34000/-45kWto50kW |
| 18.1(Marking) |
- |
0 |
|
Rs.8650/-3.7kW
Rs.9350/-3.7kWto7.5kW
Rs.10600/-7.5kWto11kW
Rs.13250/-11kW to15kW
Rs.18100/-15 kWto20kW
Rs.20950/-20kWto25kW
Rs.23800/-25kW to 30kW
Rs.26600/- 30kWto35kW
Rs.30150/-35kWto40kW
Rs.31400/-40kWto45kW
Rs.34000/-45kWto50kW |
| 18.1(Marking) |
- |
0 |
|
Rs.8650/-3.7kW
Rs.9350/-3.7kWto7.5kW
Rs.10600/-7.5kWto11kW
Rs.13250/-11kW to15kW
Rs.18100/-15 kWto20kW
Rs.20950/-20kWto25kW
Rs.23800/-25kW to 30kW
Rs.26600/- 30kWto35kW
Rs.30150/-35kWto40kW
Rs.31400/-40kWto45kW
Rs.34000/-45kWto50kW |
| 18.1(Marking) |
- |
0 |
|
Rs.8650/-3.7kW
Rs.9350/-3.7kWto7.5kW
Rs.10600/-7.5kWto11kW
Rs.13250/-11kW to15kW
Rs.18100/-15 kWto20kW
Rs.20950/-20kWto25kW
Rs.23800/-25kW to 30kW
Rs.26600/- 30kWto35kW
Rs.30150/-35kWto40kW
Rs.31400/-40kWto45kW
Rs.34000/-45kWto50kW |
| 18.1.3(Marking) |
- |
0 |
|
Rs.8650/-3.7kW
Rs.9350/-3.7kWto7.5kW
Rs.10600/-7.5kWto11kW
Rs.13250/-11kW to15kW
Rs.18100/-15 kWto20kW
Rs.20950/-20kWto25kW
Rs.23800/-25kW to 30kW
Rs.26600/- 30kWto35kW
Rs.30150/-35kWto40kW
Rs.31400/-40kWto45kW
Rs.34000/-45kWto50kW |
| 7(Constructional features) |
- |
0 |
|
Rs.8650/-3.7kW
Rs.9350/-3.7kWto7.5kW
Rs.10600/-7.5kWto11kW
Rs.13250/-11kW to15kW
Rs.18100/-15 kWto20kW
Rs.20950/-20kWto25kW
Rs.23800/-25kW to 30kW
Rs.26600/- 30kWto35kW
Rs.30150/-35kWto40kW
Rs.31400/-40kWto45kW
Rs.34000/-45kWto50kW |
| 7.1(It is recognized that a number of materials of construction are available to meet the needs for pumps handling clear, cold water.) |
- |
0 |
|
Rs.8650/-3.7kW
Rs.9350/-3.7kWto7.5kW
Rs.10600/-7.5kWto11kW
Rs.13250/-11kW to15kW
Rs.18100/-15 kWto20kW
Rs.20950/-20kWto25kW
Rs.23800/-25kW to 30kW
Rs.26600/- 30kWto35kW
Rs.30150/-35kWto40kW
Rs.31400/-40kWto45kW
Rs.34000/-45kWto50kW |
| 7.2(Gaskets, seals and packings used for clear, cold water pumps shall conform to the applicable requirements specified in 5.2 of IS 5120.) |
- |
0 |
|
Rs.8650/-3.7kW
Rs.9350/-3.7kWto7.5kW
Rs.10600/-7.5kWto11kW
Rs.13250/-11kW to15kW
Rs.18100/-15 kWto20kW
Rs.20950/-20kWto25kW
Rs.23800/-25kW to 30kW
Rs.26600/- 30kWto35kW
Rs.30150/-35kWto40kW
Rs.31400/-40kWto45kW
Rs.34000/-45kWto50kW |
| 7.3(The motor shall be provided with a breathing attachment like bellows, diaphragm etc; to compensate the volumetric variation of
water inside the motor due to change in the temperature.) |
- |
0 |
|
Rs.8650/-3.7kW
Rs.9350/-3.7kWto7.5kW
Rs.10600/-7.5kWto11kW
Rs.13250/-11kW to15kW
Rs.18100/-15 kWto20kW
Rs.20950/-20kWto25kW
Rs.23800/-25kW to 30kW
Rs.26600/- 30kWto35kW
Rs.30150/-35kWto40kW
Rs.31400/-40kWto45kW
Rs.34000/-45kWto50kW |
| 7.4(The motor shall be protected from ingress of well water, sand and other foreign matter by means of cable glands, rubber seals etc.) |
- |
0 |
|
Rs.8650/-3.7kW
Rs.9350/-3.7kWto7.5kW
Rs.10600/-7.5kWto11kW
Rs.13250/-11kW to15kW
Rs.18100/-15 kWto20kW
Rs.20950/-20kWto25kW
Rs.23800/-25kW to 30kW
Rs.26600/- 30kWto35kW
Rs.30150/-35kWto40kW
Rs.31400/-40kWto45kW
Rs.34000/-45kWto50kW |
| 7.5(All materials and components for the motor shall be suitable for application in respect of resistance and mechanical performance
to protect it) |
- |
0 |
|
Rs.8650/-3.7kW
Rs.9350/-3.7kWto7.5kW
Rs.10600/-7.5kWto11kW
Rs.13250/-11kW to15kW
Rs.18100/-15 kWto20kW
Rs.20950/-20kWto25kW
Rs.23800/-25kW to 30kW
Rs.26600/- 30kWto35kW
Rs.30150/-35kWto40kW
Rs.31400/-40kWto45kW
Rs.34000/-45kWto50kW |
| 7.6(The rotor of the wet type open well submersible motor and rotor in water filled designed motor shall be provided with suitable coating
from corrosion under water. However if suitable anticorrosion additive is added in the water, no separate protection on
rotors is necessary.) |
- |
0 |
|
Rs.8650/-3.7kW
Rs.9350/-3.7kWto7.5kW
Rs.10600/-7.5kWto11kW
Rs.13250/-11kW to15kW
Rs.18100/-15 kWto20kW
Rs.20950/-20kWto25kW
Rs.23800/-25kW to 30kW
Rs.26600/- 30kWto35kW
Rs.30150/-35kWto40kW
Rs.31400/-40kWto45kW
Rs.34000/-45kWto50kW |
| 8(Design Features) |
- |
0 |
|
Rs.8650/-3.7kW
Rs.9350/-3.7kWto7.5kW
Rs.10600/-7.5kWto11kW
Rs.13250/-11kW to15kW
Rs.18100/-15 kWto20kW
Rs.20950/-20kWto25kW
Rs.23800/-25kW to 30kW
Rs.26600/- 30kWto35kW
Rs.30150/-35kWto40kW
Rs.31400/-40kWto45kW
Rs.34000/-45kWto50kW |
| 8.1.2(The multi-stage pump shaft may be guided through bearings, the bearings may be provided in stage casing, suction housing and
discharge casing, while in case of intermediate bearings, suitable positions may be selected in the overall span.) |
- |
0 |
|
Rs.8650/-3.7kW
Rs.9350/-3.7kWto7.5kW
Rs.10600/-7.5kWto11kW
Rs.13250/-11kW to15kW
Rs.18100/-15 kWto20kW
Rs.20950/-20kWto25kW
Rs.23800/-25kW to 30kW
Rs.26600/- 30kWto35kW
Rs.30150/-35kWto40kW
Rs.31400/-40kWto45kW
Rs.34000/-45kWto50kW |
| 8.1.3(The pump may be equipped with replaceable bearing and wearing ring, wherever provided.) |
- |
0 |
|
Rs.8650/-3.7kW
Rs.9350/-3.7kWto7.5kW
Rs.10600/-7.5kWto11kW
Rs.13250/-11kW to15kW
Rs.18100/-15 kWto20kW
Rs.20950/-20kWto25kW
Rs.23800/-25kW to 30kW
Rs.26600/- 30kWto35kW
Rs.30150/-35kWto40kW
Rs.31400/-40kWto45kW
Rs.34000/-45kWto50kW |
| 8.1.4(The strainer on the suction shall offer the best compromise amongst restraining large solids from entering the pump and containing
the suction losses to the minimum.) |
- |
0 |
|
Rs.8650/-3.7kW
Rs.9350/-3.7kWto7.5kW
Rs.10600/-7.5kWto11kW
Rs.13250/-11kW to15kW
Rs.18100/-15 kWto20kW
Rs.20950/-20kWto25kW
Rs.23800/-25kW to 30kW
Rs.26600/- 30kWto35kW
Rs.30150/-35kWto40kW
Rs.31400/-40kWto45kW
Rs.34000/-45kWto50kW |
| 8.1.5(The pump shall be capable to give discharge without overloading the prime mover within the permissible current at rated voltage
and supply frequency at minimum +5 percent and minimum –15 percent of the guaranteed duty point head up to 30 m.
Above 30 m, the pump shall be capable to give discharge without overloading the prime mover within the permissible current at rated
voltage and supply frequency at minimum +10 percent and minimum –25 percent of the guaranteed duty point head.) |
- |
0 |
|
Rs.8650/-3.7kW
Rs.9350/-3.7kWto7.5kW
Rs.10600/-7.5kWto11kW
Rs.13250/-11kW to15kW
Rs.18100/-15 kWto20kW
Rs.20950/-20kWto25kW
Rs.23800/-25kW to 30kW
Rs.26600/- 30kWto35kW
Rs.30150/-35kWto40kW
Rs.31400/-40kWto45kW
Rs.34000/-45kWto50kW |
| 12(Cable) |
- |
0 |
|
Rs.8650/-3.7kW
Rs.9350/-3.7kWto7.5kW
Rs.10600/-7.5kWto11kW
Rs.13250/-11kW to15kW
Rs.18100/-15 kWto20kW
Rs.20950/-20kWto25kW
Rs.23800/-25kW to 30kW
Rs.26600/- 30kWto35kW
Rs.30150/-35kWto40kW
Rs.31400/-40kWto45kW
Rs.34000/-45kWto50kW |
| 12.1(Flat/Round cables as per IS694 shall be used) |
- |
0 |
|
Rs.8650/-3.7kW
Rs.9350/-3.7kWto7.5kW
Rs.10600/-7.5kWto11kW
Rs.13250/-11kW to15kW
Rs.18100/-15 kWto20kW
Rs.20950/-20kWto25kW
Rs.23800/-25kW to 30kW
Rs.26600/- 30kWto35kW
Rs.30150/-35kWto40kW
Rs.31400/-40kWto45kW
Rs.34000/-45kWto50kW |
| 12.1.2(The size of the conductor shall be adequate and suitable for contineous use under water and in air.
the length of the cable shall be minimum 2 m externallly unless otherwise specified by the customer) |
- |
0 |
|
Rs.8650/-3.7kW
Rs.9350/-3.7kWto7.5kW
Rs.10600/-7.5kWto11kW
Rs.13250/-11kW to15kW
Rs.18100/-15 kWto20kW
Rs.20950/-20kWto25kW
Rs.23800/-25kW to 30kW
Rs.26600/- 30kWto35kW
Rs.30150/-35kWto40kW
Rs.31400/-40kWto45kW
Rs.34000/-45kWto50kW |
| 12.1.3(The size and of the cable should be suitably selected so that the voltage drop between control panel and the mptor terminal does
not exeed three percent of the rated voltage) |
- |
0 |
|
Rs.8650/-3.7kW
Rs.9350/-3.7kWto7.5kW
Rs.10600/-7.5kWto11kW
Rs.13250/-11kW to15kW
Rs.18100/-15 kWto20kW
Rs.20950/-20kWto25kW
Rs.23800/-25kW to 30kW
Rs.26600/- 30kWto35kW
Rs.30150/-35kWto40kW
Rs.31400/-40kWto45kW
Rs.34000/-45kWto50kW |
| 12.1.4(In case a joint is required to be made between the lead cable supplied with the motor and the user’s cable, a detailed procedure to
make water tight joining shall be supplied by the motor manufacturer.) |
- |
0 |
|
Rs.8650/-3.7kW
Rs.9350/-3.7kWto7.5kW
Rs.10600/-7.5kWto11kW
Rs.13250/-11kW to15kW
Rs.18100/-15 kWto20kW
Rs.20950/-20kWto25kW
Rs.23800/-25kW to 30kW
Rs.26600/- 30kWto35kW
Rs.30150/-35kWto40kW
Rs.31400/-40kWto45kW
Rs.34000/-45kWto50kW |
| 12.1.5(If four core cable is used, the fourth core is to be used for earthing.) |
- |
0 |
|
Rs.8650/-3.7kW
Rs.9350/-3.7kWto7.5kW
Rs.10600/-7.5kWto11kW
Rs.13250/-11kW to15kW
Rs.18100/-15 kWto20kW
Rs.20950/-20kWto25kW
Rs.23800/-25kW to 30kW
Rs.26600/- 30kWto35kW
Rs.30150/-35kWto40kW
Rs.31400/-40kWto45kW
Rs.34000/-45kWto50kW |
| 14.10.1(Type test) |
- |
0 |
|
Rs.8650/-3.7kW
Rs.9350/-3.7kWto7.5kW
Rs.10600/-7.5kWto11kW
Rs.13250/-11kW to15kW
Rs.18100/-15 kWto20kW
Rs.20950/-20kWto25kW
Rs.23800/-25kW to 30kW
Rs.26600/- 30kWto35kW
Rs.30150/-35kWto40kW
Rs.31400/-40kWto45kW
Rs.34000/-45kWto50kW |
| 14.10.1(a)(Insulation Resistance test) |
- |
0 |
|
Rs.8650/-3.7kW
Rs.9350/-3.7kWto7.5kW
Rs.10600/-7.5kWto11kW
Rs.13250/-11kW to15kW
Rs.18100/-15 kWto20kW
Rs.20950/-20kWto25kW
Rs.23800/-25kW to 30kW
Rs.26600/- 30kWto35kW
Rs.30150/-35kWto40kW
Rs.31400/-40kWto45kW
Rs.34000/-45kWto50kW |
| 14.10.1(b)(High Voltage test) |
- |
0 |
|
Rs.8650/-3.7kW
Rs.9350/-3.7kWto7.5kW
Rs.10600/-7.5kWto11kW
Rs.13250/-11kW to15kW
Rs.18100/-15 kWto20kW
Rs.20950/-20kWto25kW
Rs.23800/-25kW to 30kW
Rs.26600/- 30kWto35kW
Rs.30150/-35kWto40kW
Rs.31400/-40kWto45kW
Rs.34000/-45kWto50kW |
| 14.10.1(c)(Measurement of stator resistance) |
- |
0 |
|
Rs.8650/-3.7kW
Rs.9350/-3.7kWto7.5kW
Rs.10600/-7.5kWto11kW
Rs.13250/-11kW to15kW
Rs.18100/-15 kWto20kW
Rs.20950/-20kWto25kW
Rs.23800/-25kW to 30kW
Rs.26600/- 30kWto35kW
Rs.30150/-35kWto40kW
Rs.31400/-40kWto45kW
Rs.34000/-45kWto50kW |
| 14.10.1(d)(No load test at rated voltage) |
- |
0 |
|
Rs.8650/-3.7kW
Rs.9350/-3.7kWto7.5kW
Rs.10600/-7.5kWto11kW
Rs.13250/-11kW to15kW
Rs.18100/-15 kWto20kW
Rs.20950/-20kWto25kW
Rs.23800/-25kW to 30kW
Rs.26600/- 30kWto35kW
Rs.30150/-35kWto40kW
Rs.31400/-40kWto45kW
Rs.34000/-45kWto50kW |
| 14.10.1(e)(Reduced voltage running up test at no load) |
- |
0 |
|
Rs.8650/-3.7kW
Rs.9350/-3.7kWto7.5kW
Rs.10600/-7.5kWto11kW
Rs.13250/-11kW to15kW
Rs.18100/-15 kWto20kW
Rs.20950/-20kWto25kW
Rs.23800/-25kW to 30kW
Rs.26600/- 30kWto35kW
Rs.30150/-35kWto40kW
Rs.31400/-40kWto45kW
Rs.34000/-45kWto50kW |
| 14.10.1(f)(Locked rotor) |
- |
0 |
|
Rs.8650/-3.7kW
Rs.9350/-3.7kWto7.5kW
Rs.10600/-7.5kWto11kW
Rs.13250/-11kW to15kW
Rs.18100/-15 kWto20kW
Rs.20950/-20kWto25kW
Rs.23800/-25kW to 30kW
Rs.26600/- 30kWto35kW
Rs.30150/-35kWto40kW
Rs.31400/-40kWto45kW
Rs.34000/-45kWto50kW |
| 14.10.1(g)(Breakaway (starting) torque) |
- |
0 |
|
Rs.8650/-3.7kW
Rs.9350/-3.7kWto7.5kW
Rs.10600/-7.5kWto11kW
Rs.13250/-11kW to15kW
Rs.18100/-15 kWto20kW
Rs.20950/-20kWto25kW
Rs.23800/-25kW to 30kW
Rs.26600/- 30kWto35kW
Rs.30150/-35kWto40kW
Rs.31400/-40kWto45kW
Rs.34000/-45kWto50kW |
| 14.10.1(h)(Leakage current test;) |
- |
0 |
|
Rs.8650/-3.7kW
Rs.9350/-3.7kWto7.5kW
Rs.10600/-7.5kWto11kW
Rs.13250/-11kW to15kW
Rs.18100/-15 kWto20kW
Rs.20950/-20kWto25kW
Rs.23800/-25kW to 30kW
Rs.26600/- 30kWto35kW
Rs.30150/-35kWto40kW
Rs.31400/-40kWto45kW
Rs.34000/-45kWto50kW |
| 14.10.1(j)(Temperature rise test at rated voltage) |
- |
0 |
|
Rs.8650/-3.7kW
Rs.9350/-3.7kWto7.5kW
Rs.10600/-7.5kWto11kW
Rs.13250/-11kW to15kW
Rs.18100/-15 kWto20kW
Rs.20950/-20kWto25kW
Rs.23800/-25kW to 30kW
Rs.26600/- 30kWto35kW
Rs.30150/-35kWto40kW
Rs.31400/-40kWto45kW
Rs.34000/-45kWto50kW |
| 14.10.1(k)(Temperature rise test at reduced voltage) |
- |
0 |
|
Rs.8650/-3.7kW
Rs.9350/-3.7kWto7.5kW
Rs.10600/-7.5kWto11kW
Rs.13250/-11kW to15kW
Rs.18100/-15 kWto20kW
Rs.20950/-20kWto25kW
Rs.23800/-25kW to 30kW
Rs.26600/- 30kWto35kW
Rs.30150/-35kWto40kW
Rs.31400/-40kWto45kW
Rs.34000/-45kWto50kW |
| 16.1(Guarntee of Performance) |
- |
0 |
|
Rs.8650/-3.7kW
Rs.9350/-3.7kWto7.5kW
Rs.10600/-7.5kWto11kW
Rs.13250/-11kW to15kW
Rs.18100/-15 kWto20kW
Rs.20950/-20kWto25kW
Rs.23800/-25kW to 30kW
Rs.26600/- 30kWto35kW
Rs.30150/-35kWto40kW
Rs.31400/-40kWto45kW
Rs.34000/-45kWto50kW |
| 16.1.1(The pumpset shall be guaranteed for their performance of the nominal volume rate of flow and the nominal head at the guaranteed
duty point. The overall efficiency of the pumpset shall be guaranteed at the declared duty point only.) |
- |
0 |
|
Rs.8650/-3.7kW
Rs.9350/-3.7kWto7.5kW
Rs.10600/-7.5kWto11kW
Rs.13250/-11kW to15kW
Rs.18100/-15 kWto20kW
Rs.20950/-20kWto25kW
Rs.23800/-25kW to 30kW
Rs.26600/- 30kWto35kW
Rs.30150/-35kWto40kW
Rs.31400/-40kWto45kW
Rs.34000/-45kWto50kW |
| 16.1.2(The guarantee shall be deemed to have been met with, if the measured values of head, volume rate of flow and overall efficiency
are within the indicated in IS 11346 limits) |
- |
0 |
|
Rs.8650/-3.7kW
Rs.9350/-3.7kWto7.5kW
Rs.10600/-7.5kWto11kW
Rs.13250/-11kW to15kW
Rs.18100/-15 kWto20kW
Rs.20950/-20kWto25kW
Rs.23800/-25kW to 30kW
Rs.26600/- 30kWto35kW
Rs.30150/-35kWto40kW
Rs.31400/-40kWto45kW
Rs.34000/-45kWto50kW |
| 16.1.3(Open well submersible motor shall not get overloaded in the specified operating head range at rated voltage and supply frequency.) |
- |
0 |
|
Rs.8650/-3.7kW
Rs.9350/-3.7kWto7.5kW
Rs.10600/-7.5kWto11kW
Rs.13250/-11kW to15kW
Rs.18100/-15 kWto20kW
Rs.20950/-20kWto25kW
Rs.23800/-25kW to 30kW
Rs.26600/- 30kWto35kW
Rs.30150/-35kWto40kW
Rs.31400/-40kWto45kW
Rs.34000/-45kWto50kW |
| 16.1.4(The pump shall be tested for the operating head range as per 8.1.5.) |
- |
0 |
|
Rs.8650/-3.7kW
Rs.9350/-3.7kWto7.5kW
Rs.10600/-7.5kWto11kW
Rs.13250/-11kW to15kW
Rs.18100/-15 kWto20kW
Rs.20950/-20kWto25kW
Rs.23800/-25kW to 30kW
Rs.26600/- 30kWto35kW
Rs.30150/-35kWto40kW
Rs.31400/-40kWto45kW
Rs.34000/-45kWto50kW |
| 16.1.5(The overloading of motor is that condition when maximum current drawn by the motor exceeds the limit of 1.07 times of the rated
motor current) |
- |
0 |
|
Rs.8650/-3.7kW
Rs.9350/-3.7kWto7.5kW
Rs.10600/-7.5kWto11kW
Rs.13250/-11kW to15kW
Rs.18100/-15 kWto20kW
Rs.20950/-20kWto25kW
Rs.23800/-25kW to 30kW
Rs.26600/- 30kWto35kW
Rs.30150/-35kWto40kW
Rs.31400/-40kWto45kW
Rs.34000/-45kWto50kW |
| 16.1.6(The tolerance shall apply to guaranteed duty point only.) |
- |
0 |
|
Rs.8650/-3.7kW
Rs.9350/-3.7kWto7.5kW
Rs.10600/-7.5kWto11kW
Rs.13250/-11kW to15kW
Rs.18100/-15 kWto20kW
Rs.20950/-20kWto25kW
Rs.23800/-25kW to 30kW
Rs.26600/- 30kWto35kW
Rs.30150/-35kWto40kW
Rs.31400/-40kWto45kW
Rs.34000/-45kWto50kW |
| 16.1.7(Performance at rated voltage and supply frequency is actual performance of the set. This is better than performance at rated speed,
since in the entire operating head range speed of motor is higher than rated speed, as motor is running in under loaded condition.) |
- |
0 |
|
Rs.8650/-3.7kW
Rs.9350/-3.7kWto7.5kW
Rs.10600/-7.5kWto11kW
Rs.13250/-11kW to15kW
Rs.18100/-15 kWto20kW
Rs.20950/-20kWto25kW
Rs.23800/-25kW to 30kW
Rs.26600/- 30kWto35kW
Rs.30150/-35kWto40kW
Rs.31400/-40kWto45kW
Rs.34000/-45kWto50kW |
| 16.1.8(The manufacturer shall specify the minimum submergence of pump unit at duty point.) |
- |
0 |
|
Rs.8650/-3.7kW
Rs.9350/-3.7kWto7.5kW
Rs.10600/-7.5kWto11kW
Rs.13250/-11kW to15kW
Rs.18100/-15 kWto20kW
Rs.20950/-20kWto25kW
Rs.23800/-25kW to 30kW
Rs.26600/- 30kWto35kW
Rs.30150/-35kWto40kW
Rs.31400/-40kWto45kW
Rs.34000/-45kWto50kW |
| 18.1(Marking) |
- |
0 |
|
Rs.8650/-3.7kW
Rs.9350/-3.7kWto7.5kW
Rs.10600/-7.5kWto11kW
Rs.13250/-11kW to15kW
Rs.18100/-15 kWto20kW
Rs.20950/-20kWto25kW
Rs.23800/-25kW to 30kW
Rs.26600/- 30kWto35kW
Rs.30150/-35kWto40kW
Rs.31400/-40kWto45kW
Rs.34000/-45kWto50kW |
| 18.1(Marking) |
- |
0 |
|
Rs.8650/-3.7kW
Rs.9350/-3.7kWto7.5kW
Rs.10600/-7.5kWto11kW
Rs.13250/-11kW to15kW
Rs.18100/-15 kWto20kW
Rs.20950/-20kWto25kW
Rs.23800/-25kW to 30kW
Rs.26600/- 30kWto35kW
Rs.30150/-35kWto40kW
Rs.31400/-40kWto45kW
Rs.34000/-45kWto50kW |
| 18.1(Marking) |
- |
0 |
|
Rs.8650/-3.7kW
Rs.9350/-3.7kWto7.5kW
Rs.10600/-7.5kWto11kW
Rs.13250/-11kW to15kW
Rs.18100/-15 kWto20kW
Rs.20950/-20kWto25kW
Rs.23800/-25kW to 30kW
Rs.26600/- 30kWto35kW
Rs.30150/-35kWto40kW
Rs.31400/-40kWto45kW
Rs.34000/-45kWto50kW |
| 18.1(Marking) |
- |
0 |
|
Rs.8650/-3.7kW
Rs.9350/-3.7kWto7.5kW
Rs.10600/-7.5kWto11kW
Rs.13250/-11kW to15kW
Rs.18100/-15 kWto20kW
Rs.20950/-20kWto25kW
Rs.23800/-25kW to 30kW
Rs.26600/- 30kWto35kW
Rs.30150/-35kWto40kW
Rs.31400/-40kWto45kW
Rs.34000/-45kWto50kW |
| 18.1(Marking) |
- |
0 |
|
Rs.8650/-3.7kW
Rs.9350/-3.7kWto7.5kW
Rs.10600/-7.5kWto11kW
Rs.13250/-11kW to15kW
Rs.18100/-15 kWto20kW
Rs.20950/-20kWto25kW
Rs.23800/-25kW to 30kW
Rs.26600/- 30kWto35kW
Rs.30150/-35kWto40kW
Rs.31400/-40kWto45kW
Rs.34000/-45kWto50kW |
| 16.4.1 (Amendment-1)(Pump efficiency) |
- |
0 |
|
Rs.8650/-3.7kW
Rs.9350/-3.7kWto7.5kW
Rs.10600/-7.5kWto11kW
Rs.13250/-11kW to15kW
Rs.18100/-15 kWto20kW
Rs.20950/-20kWto25kW
Rs.23800/-25kW to 30kW
Rs.26600/- 30kWto35kW
Rs.30150/-35kWto40kW
Rs.31400/-40kWto45kW
Rs.34000/-45kWto50kW |
| 9 (Amendment-1)(EFFICIENCY) |
- |
0 |
|
Rs.8650/-3.7kW
Rs.9350/-3.7kWto7.5kW
Rs.10600/-7.5kWto11kW
Rs.13250/-11kW to15kW
Rs.18100/-15 kWto20kW
Rs.20950/-20kWto25kW
Rs.23800/-25kW to 30kW
Rs.26600/- 30kWto35kW
Rs.30150/-35kWto40kW
Rs.31400/-40kWto45kW
Rs.34000/-45kWto50kW |
|
28 Oct, 2028 |
- - |
| 13 |
IS 9283 (2024) |
LINE OPERATED A.C. MOTORS FOR SUBMERSIBLE PUMPSETS - SPECIFICATION (THIRD REVISION) |
0 |
4400 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| As Per Clause 5.1.2 Table 1(Material) |
- |
0 |
|
Rs.4400/-3.7kW
Rs.4750/-3.7kWto7.5kW
Rs.5400/-7.5kWto11kW
Rs.6700/-11kW to15kW
Rs.9200/-15 kWto20kW
Rs.10600/-20kWto25kW
Rs.12000/-25kW to 30kW
Rs.13350/- 30kWto35kW
Rs.15450/-35kWto40kW
Rs.16450/-40kWto45kW
Rs.17500/-45kWto50kW |
| As Per Clause 5.1.3(Construction-General) |
- |
0 |
|
Rs.4400/-3.7kW
Rs.4750/-3.7kWto7.5kW
Rs.5400/-7.5kWto11kW
Rs.6700/-11kW to15kW
Rs.9200/-15 kWto20kW
Rs.10600/-20kWto25kW
Rs.12000/-25kW to 30kW
Rs.13350/- 30kWto35kW
Rs.15450/-35kWto40kW
Rs.16450/-40kWto45kW
Rs.17500/-45kWto50kW |
| As per Clause 5.1.4(Construction-General) |
- |
0 |
|
Rs.4400/-3.7kW
Rs.4750/-3.7kWto7.5kW
Rs.5400/-7.5kWto11kW
Rs.6700/-11kW to15kW
Rs.9200/-15 kWto20kW
Rs.10600/-20kWto25kW
Rs.12000/-25kW to 30kW
Rs.13350/- 30kWto35kW
Rs.15450/-35kWto40kW
Rs.16450/-40kWto45kW
Rs.17500/-45kWto50kW |
| As per Clause 5.2.1(Earthing) |
- |
0 |
|
Rs.4400/-3.7kW
Rs.4750/-3.7kWto7.5kW
Rs.5400/-7.5kWto11kW
Rs.6700/-11kW to15kW
Rs.9200/-15 kWto20kW
Rs.10600/-20kWto25kW
Rs.12000/-25kW to 30kW
Rs.13350/- 30kWto35kW
Rs.15450/-35kWto40kW
Rs.16450/-40kWto45kW
Rs.17500/-45kWto50kW |
| As per Clause 5.4.1(Construction-Type of cable & Size of conductor of cable) |
- |
0 |
|
Rs.4400/-3.7kW
Rs.4750/-3.7kWto7.5kW
Rs.5400/-7.5kWto11kW
Rs.6700/-11kW to15kW
Rs.9200/-15 kWto20kW
Rs.10600/-20kWto25kW
Rs.12000/-25kW to 30kW
Rs.13350/- 30kWto35kW
Rs.15450/-35kWto40kW
Rs.16450/-40kWto45kW
Rs.17500/-45kWto50kW |
| As per Clause 5.4.2(Construction-Length of cable) |
- |
0 |
|
Rs.4400/-3.7kW
Rs.4750/-3.7kWto7.5kW
Rs.5400/-7.5kWto11kW
Rs.6700/-11kW to15kW
Rs.9200/-15 kWto20kW
Rs.10600/-20kWto25kW
Rs.12000/-25kW to 30kW
Rs.13350/- 30kWto35kW
Rs.15450/-35kWto40kW
Rs.16450/-40kWto45kW
Rs.17500/-45kWto50kW |
| As per Clause 5.4.3(Construction-Joint in Cable) |
- |
0 |
|
Rs.4400/-3.7kW
Rs.4750/-3.7kWto7.5kW
Rs.5400/-7.5kWto11kW
Rs.6700/-11kW to15kW
Rs.9200/-15 kWto20kW
Rs.10600/-20kWto25kW
Rs.12000/-25kW to 30kW
Rs.13350/- 30kWto35kW
Rs.15450/-35kWto40kW
Rs.16450/-40kWto45kW
Rs.17500/-45kWto50kW |
| As per Clause 5.5(Finish of Bearings) |
- |
0 |
|
Rs.4400/-3.7kW
Rs.4750/-3.7kWto7.5kW
Rs.5400/-7.5kWto11kW
Rs.6700/-11kW to15kW
Rs.9200/-15 kWto20kW
Rs.10600/-20kWto25kW
Rs.12000/-25kW to 30kW
Rs.13350/- 30kWto35kW
Rs.15450/-35kWto40kW
Rs.16450/-40kWto45kW
Rs.17500/-45kWto50kW |
| As per Clause 5.6(Balancing of Rotor) |
- |
0 |
|
Rs.4400/-3.7kW
Rs.4750/-3.7kWto7.5kW
Rs.5400/-7.5kWto11kW
Rs.6700/-11kW to15kW
Rs.9200/-15 kWto20kW
Rs.10600/-20kWto25kW
Rs.12000/-25kW to 30kW
Rs.13350/- 30kWto35kW
Rs.15450/-35kWto40kW
Rs.16450/-40kWto45kW
Rs.17500/-45kWto50kW |
| As per Clause 7.1(Dimensions of Motors) |
- |
0 |
|
Rs.4400/-3.7kW
Rs.4750/-3.7kWto7.5kW
Rs.5400/-7.5kWto11kW
Rs.6700/-11kW to15kW
Rs.9200/-15 kWto20kW
Rs.10600/-20kWto25kW
Rs.12000/-25kW to 30kW
Rs.13350/- 30kWto35kW
Rs.15450/-35kWto40kW
Rs.16450/-40kWto45kW
Rs.17500/-45kWto50kW |
| As per Clause 7.2(Tolerances) |
- |
0 |
|
Rs.4400/-3.7kW
Rs.4750/-3.7kWto7.5kW
Rs.5400/-7.5kWto11kW
Rs.6700/-11kW to15kW
Rs.9200/-15 kWto20kW
Rs.10600/-20kWto25kW
Rs.12000/-25kW to 30kW
Rs.13350/- 30kWto35kW
Rs.15450/-35kWto40kW
Rs.16450/-40kWto45kW
Rs.17500/-45kWto50kW |
| As per Clause 12.1(Efficiency) |
- |
0 |
|
Rs.4400/-3.7kW
Rs.4750/-3.7kWto7.5kW
Rs.5400/-7.5kWto11kW
Rs.6700/-11kW to15kW
Rs.9200/-15 kWto20kW
Rs.10600/-20kWto25kW
Rs.12000/-25kW to 30kW
Rs.13350/- 30kWto35kW
Rs.15450/-35kWto40kW
Rs.16450/-40kWto45kW
Rs.17500/-45kWto50kW |
| As per Clause 12.1(Efficiency) |
- |
0 |
|
Rs.4400/-3.7kW
Rs.4750/-3.7kWto7.5kW
Rs.5400/-7.5kWto11kW
Rs.6700/-11kW to15kW
Rs.9200/-15 kWto20kW
Rs.10600/-20kWto25kW
Rs.12000/-25kW to 30kW
Rs.13350/- 30kWto35kW
Rs.15450/-35kWto40kW
Rs.16450/-40kWto45kW
Rs.17500/-45kWto50kW |
| As per Clause 13(Terminal Marking) |
- |
0 |
|
Rs.4400/-3.7kW
Rs.4750/-3.7kWto7.5kW
Rs.5400/-7.5kWto11kW
Rs.6700/-11kW to15kW
Rs.9200/-15 kWto20kW
Rs.10600/-20kWto25kW
Rs.12000/-25kW to 30kW
Rs.13350/- 30kWto35kW
Rs.15450/-35kWto40kW
Rs.16450/-40kWto45kW
Rs.17500/-45kWto50kW |
| As per Clause 15.1(Rating Plate) |
- |
0 |
|
Rs.4400/-3.7kW
Rs.4750/-3.7kWto7.5kW
Rs.5400/-7.5kWto11kW
Rs.6700/-11kW to15kW
Rs.9200/-15 kWto20kW
Rs.10600/-20kWto25kW
Rs.12000/-25kW to 30kW
Rs.13350/- 30kWto35kW
Rs.15450/-35kWto40kW
Rs.16450/-40kWto45kW
Rs.17500/-45kWto50kW |
| As per Clause 15.1(Rating Plate) |
- |
0 |
|
Rs.4400/-3.7kW
Rs.4750/-3.7kWto7.5kW
Rs.5400/-7.5kWto11kW
Rs.6700/-11kW to15kW
Rs.9200/-15 kWto20kW
Rs.10600/-20kWto25kW
Rs.12000/-25kW to 30kW
Rs.13350/- 30kWto35kW
Rs.15450/-35kWto40kW
Rs.16450/-40kWto45kW
Rs.17500/-45kWto50kW |
| As per Clause 15.1(Rating Plate) |
- |
0 |
|
Rs.4400/-3.7kW
Rs.4750/-3.7kWto7.5kW
Rs.5400/-7.5kWto11kW
Rs.6700/-11kW to15kW
Rs.9200/-15 kWto20kW
Rs.10600/-20kWto25kW
Rs.12000/-25kW to 30kW
Rs.13350/- 30kWto35kW
Rs.15450/-35kWto40kW
Rs.16450/-40kWto45kW
Rs.17500/-45kWto50kW |
| As per Clause 15.1(Rating Plate) |
- |
0 |
|
Rs.4400/-3.7kW
Rs.4750/-3.7kWto7.5kW
Rs.5400/-7.5kWto11kW
Rs.6700/-11kW to15kW
Rs.9200/-15 kWto20kW
Rs.10600/-20kWto25kW
Rs.12000/-25kW to 30kW
Rs.13350/- 30kWto35kW
Rs.15450/-35kWto40kW
Rs.16450/-40kWto45kW
Rs.17500/-45kWto50kW |
| As per Clause 15.1(Rating Plate) |
- |
0 |
|
Rs.4400/-3.7kW
Rs.4750/-3.7kWto7.5kW
Rs.5400/-7.5kWto11kW
Rs.6700/-11kW to15kW
Rs.9200/-15 kWto20kW
Rs.10600/-20kWto25kW
Rs.12000/-25kW to 30kW
Rs.13350/- 30kWto35kW
Rs.15450/-35kWto40kW
Rs.16450/-40kWto45kW
Rs.17500/-45kWto50kW |
| As per Clause 15.1(Rating Plate) |
- |
0 |
|
Rs.4400/-3.7kW
Rs.4750/-3.7kWto7.5kW
Rs.5400/-7.5kWto11kW
Rs.6700/-11kW to15kW
Rs.9200/-15 kWto20kW
Rs.10600/-20kWto25kW
Rs.12000/-25kW to 30kW
Rs.13350/- 30kWto35kW
Rs.15450/-35kWto40kW
Rs.16450/-40kWto45kW
Rs.17500/-45kWto50kW |
| As per Clause 15.1(Rating Plate) |
- |
0 |
|
Rs.4400/-3.7kW
Rs.4750/-3.7kWto7.5kW
Rs.5400/-7.5kWto11kW
Rs.6700/-11kW to15kW
Rs.9200/-15 kWto20kW
Rs.10600/-20kWto25kW
Rs.12000/-25kW to 30kW
Rs.13350/- 30kWto35kW
Rs.15450/-35kWto40kW
Rs.16450/-40kWto45kW
Rs.17500/-45kWto50kW |
| As per Clause 15.1(Rating Plate) |
- |
0 |
|
Rs.4400/-3.7kW
Rs.4750/-3.7kWto7.5kW
Rs.5400/-7.5kWto11kW
Rs.6700/-11kW to15kW
Rs.9200/-15 kWto20kW
Rs.10600/-20kWto25kW
Rs.12000/-25kW to 30kW
Rs.13350/- 30kWto35kW
Rs.15450/-35kWto40kW
Rs.16450/-40kWto45kW
Rs.17500/-45kWto50kW |
| As per Clause 15.1(Rating Plate) |
- |
0 |
|
Rs.4400/-3.7kW
Rs.4750/-3.7kWto7.5kW
Rs.5400/-7.5kWto11kW
Rs.6700/-11kW to15kW
Rs.9200/-15 kWto20kW
Rs.10600/-20kWto25kW
Rs.12000/-25kW to 30kW
Rs.13350/- 30kWto35kW
Rs.15450/-35kWto40kW
Rs.16450/-40kWto45kW
Rs.17500/-45kWto50kW |
| As per Clause 15.1(Rating Plate) |
- |
0 |
|
Rs.4400/-3.7kW
Rs.4750/-3.7kWto7.5kW
Rs.5400/-7.5kWto11kW
Rs.6700/-11kW to15kW
Rs.9200/-15 kWto20kW
Rs.10600/-20kWto25kW
Rs.12000/-25kW to 30kW
Rs.13350/- 30kWto35kW
Rs.15450/-35kWto40kW
Rs.16450/-40kWto45kW
Rs.17500/-45kWto50kW |
| As per Clause 15.1(Rating Plate) |
- |
0 |
|
Rs.4400/-3.7kW
Rs.4750/-3.7kWto7.5kW
Rs.5400/-7.5kWto11kW
Rs.6700/-11kW to15kW
Rs.9200/-15 kWto20kW
Rs.10600/-20kWto25kW
Rs.12000/-25kW to 30kW
Rs.13350/- 30kWto35kW
Rs.15450/-35kWto40kW
Rs.16450/-40kWto45kW
Rs.17500/-45kWto50kW |
| As per Clause 15.1(Rating Plate) |
- |
0 |
|
Rs.4400/-3.7kW
Rs.4750/-3.7kWto7.5kW
Rs.5400/-7.5kWto11kW
Rs.6700/-11kW to15kW
Rs.9200/-15 kWto20kW
Rs.10600/-20kWto25kW
Rs.12000/-25kW to 30kW
Rs.13350/- 30kWto35kW
Rs.15450/-35kWto40kW
Rs.16450/-40kWto45kW
Rs.17500/-45kWto50kW |
| As per Clause 15.1(Rating Plate) |
- |
0 |
|
Rs.4400/-3.7kW
Rs.4750/-3.7kWto7.5kW
Rs.5400/-7.5kWto11kW
Rs.6700/-11kW to15kW
Rs.9200/-15 kWto20kW
Rs.10600/-20kWto25kW
Rs.12000/-25kW to 30kW
Rs.13350/- 30kWto35kW
Rs.15450/-35kWto40kW
Rs.16450/-40kWto45kW
Rs.17500/-45kWto50kW |
| As per Clause 15.1(Rating Plate) |
- |
0 |
|
Rs.4400/-3.7kW
Rs.4750/-3.7kWto7.5kW
Rs.5400/-7.5kWto11kW
Rs.6700/-11kW to15kW
Rs.9200/-15 kWto20kW
Rs.10600/-20kWto25kW
Rs.12000/-25kW to 30kW
Rs.13350/- 30kWto35kW
Rs.15450/-35kWto40kW
Rs.16450/-40kWto45kW
Rs.17500/-45kWto50kW |
| As per Clause 15.1(Rating Plate) |
- |
0 |
|
Rs.4400/-3.7kW
Rs.4750/-3.7kWto7.5kW
Rs.5400/-7.5kWto11kW
Rs.6700/-11kW to15kW
Rs.9200/-15 kWto20kW
Rs.10600/-20kWto25kW
Rs.12000/-25kW to 30kW
Rs.13350/- 30kWto35kW
Rs.15450/-35kWto40kW
Rs.16450/-40kWto45kW
Rs.17500/-45kWto50kW |
| As per Clause 15.2(Rating Plate) |
- |
0 |
|
Rs.4400/-3.7kW
Rs.4750/-3.7kWto7.5kW
Rs.5400/-7.5kWto11kW
Rs.6700/-11kW to15kW
Rs.9200/-15 kWto20kW
Rs.10600/-20kWto25kW
Rs.12000/-25kW to 30kW
Rs.13350/- 30kWto35kW
Rs.15450/-35kWto40kW
Rs.16450/-40kWto45kW
Rs.17500/-45kWto50kW |
| As per Clause 16.1(a),21(Insulationresistance test(Before HV Test)) |
- |
0 |
|
Rs.4400/-3.7kW
Rs.4750/-3.7kWto7.5kW
Rs.5400/-7.5kWto11kW
Rs.6700/-11kW to15kW
Rs.9200/-15 kWto20kW
Rs.10600/-20kWto25kW
Rs.12000/-25kW to 30kW
Rs.13350/- 30kWto35kW
Rs.15450/-35kWto40kW
Rs.16450/-40kWto45kW
Rs.17500/-45kWto50kW |
| As per Clause 16.1(a),21(Insulationresistance test(After HV Test)) |
- |
0 |
|
Rs.4400/-3.7kW
Rs.4750/-3.7kWto7.5kW
Rs.5400/-7.5kWto11kW
Rs.6700/-11kW to15kW
Rs.9200/-15 kWto20kW
Rs.10600/-20kWto25kW
Rs.12000/-25kW to 30kW
Rs.13350/- 30kWto35kW
Rs.15450/-35kWto40kW
Rs.16450/-40kWto45kW
Rs.17500/-45kWto50kW |
| As per Clause 16.1(b),20(High voltage test) |
- |
0 |
|
Rs.4400/-3.7kW
Rs.4750/-3.7kWto7.5kW
Rs.5400/-7.5kWto11kW
Rs.6700/-11kW to15kW
Rs.9200/-15 kWto20kW
Rs.10600/-20kWto25kW
Rs.12000/-25kW to 30kW
Rs.13350/- 30kWto35kW
Rs.15450/-35kWto40kW
Rs.16450/-40kWto45kW
Rs.17500/-45kWto50kW |
| As per Clause 16.[c](Measurement of stator resistance) |
- |
0 |
|
Rs.4400/-3.7kW
Rs.4750/-3.7kWto7.5kW
Rs.5400/-7.5kWto11kW
Rs.6700/-11kW to15kW
Rs.9200/-15 kWto20kW
Rs.10600/-20kWto25kW
Rs.12000/-25kW to 30kW
Rs.13350/- 30kWto35kW
Rs.15450/-35kWto40kW
Rs.16450/-40kWto45kW
Rs.17500/-45kWto50kW |
| As per Clause 16.(d)(No Load Test) |
- |
0 |
|
Rs.4400/-3.7kW
Rs.4750/-3.7kWto7.5kW
Rs.5400/-7.5kWto11kW
Rs.6700/-11kW to15kW
Rs.9200/-15 kWto20kW
Rs.10600/-20kWto25kW
Rs.12000/-25kW to 30kW
Rs.13350/- 30kWto35kW
Rs.15450/-35kWto40kW
Rs.16450/-40kWto45kW
Rs.17500/-45kWto50kW |
| As per Clause 16.(e)(Reduced voltage running up test at no load) |
- |
0 |
|
Rs.4400/-3.7kW
Rs.4750/-3.7kWto7.5kW
Rs.5400/-7.5kWto11kW
Rs.6700/-11kW to15kW
Rs.9200/-15 kWto20kW
Rs.10600/-20kWto25kW
Rs.12000/-25kW to 30kW
Rs.13350/- 30kWto35kW
Rs.15450/-35kWto40kW
Rs.16450/-40kWto45kW
Rs.17500/-45kWto50kW |
| As per Clause 16.(f)(Locked rotor readings of voltage, current, power input and torque of motors) |
- |
0 |
|
Rs.4400/-3.7kW
Rs.4750/-3.7kWto7.5kW
Rs.5400/-7.5kWto11kW
Rs.6700/-11kW to15kW
Rs.9200/-15 kWto20kW
Rs.10600/-20kWto25kW
Rs.12000/-25kW to 30kW
Rs.13350/- 30kWto35kW
Rs.15450/-35kWto40kW
Rs.16450/-40kWto45kW
Rs.17500/-45kWto50kW |
| As per Clause 16.(g)(Full load reading of voltage, current, power input, speed and frequency) |
- |
0 |
|
Rs.4400/-3.7kW
Rs.4750/-3.7kWto7.5kW
Rs.5400/-7.5kWto11kW
Rs.6700/-11kW to15kW
Rs.9200/-15 kWto20kW
Rs.10600/-20kWto25kW
Rs.12000/-25kW to 30kW
Rs.13350/- 30kWto35kW
Rs.15450/-35kWto40kW
Rs.16450/-40kWto45kW
Rs.17500/-45kWto50kW |
| As per Clause 16.(h),11(Performance characteristics) |
- |
0 |
|
Rs.4400/-3.7kW
Rs.4750/-3.7kWto7.5kW
Rs.5400/-7.5kWto11kW
Rs.6700/-11kW to15kW
Rs.9200/-15 kWto20kW
Rs.10600/-20kWto25kW
Rs.12000/-25kW to 30kW
Rs.13350/- 30kWto35kW
Rs.15450/-35kWto40kW
Rs.16450/-40kWto45kW
Rs.17500/-45kWto50kW |
| As per Clause 16.(j),19(Temperature rise test at rated voltage) |
- |
0 |
|
Rs.4400/-3.7kW
Rs.4750/-3.7kWto7.5kW
Rs.5400/-7.5kWto11kW
Rs.6700/-11kW to15kW
Rs.9200/-15 kWto20kW
Rs.10600/-20kWto25kW
Rs.12000/-25kW to 30kW
Rs.13350/- 30kWto35kW
Rs.15450/-35kWto40kW
Rs.16450/-40kWto45kW
Rs.17500/-45kWto50kW |
| As per Clause 16.(k),19(Temperature rise test at reduced voltage) |
- |
0 |
|
Rs.4400/-3.7kW
Rs.4750/-3.7kWto7.5kW
Rs.5400/-7.5kWto11kW
Rs.6700/-11kW to15kW
Rs.9200/-15 kWto20kW
Rs.10600/-20kWto25kW
Rs.12000/-25kW to 30kW
Rs.13350/- 30kWto35kW
Rs.15450/-35kWto40kW
Rs.16450/-40kWto45kW
Rs.17500/-45kWto50kW |
| As per Clause 16.(m),18(Momentary Overload Test) |
- |
0 |
|
Rs.4400/-3.7kW
Rs.4750/-3.7kWto7.5kW
Rs.5400/-7.5kWto11kW
Rs.6700/-11kW to15kW
Rs.9200/-15 kWto20kW
Rs.10600/-20kWto25kW
Rs.12000/-25kW to 30kW
Rs.13350/- 30kWto35kW
Rs.15450/-35kWto40kW
Rs.16450/-40kWto45kW
Rs.17500/-45kWto50kW |
| As per Clause 16.(n),22(Leakage Current Test at rated voltage at no load) |
- |
0 |
|
Rs.4400/-3.7kW
Rs.4750/-3.7kWto7.5kW
Rs.5400/-7.5kWto11kW
Rs.6700/-11kW to15kW
Rs.9200/-15 kWto20kW
Rs.10600/-20kWto25kW
Rs.12000/-25kW to 30kW
Rs.13350/- 30kWto35kW
Rs.15450/-35kWto40kW
Rs.16450/-40kWto45kW
Rs.17500/-45kWto50kW |
|
28 Oct, 2028 |
- - |
| 14 |
IS 617 (2024) |
Aluminium and Aluminium Alloys Ingots for Remelting and Castings for General Engineering Purposes â Specification (Fourth Revision) |
- |
7450 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl-6.1, Table-1(Si) |
- |
650 |
|
- |
| Cl-6.1, Table-1(Fe) |
- |
650 |
|
- |
| Cl-6.1, Table-1(Cu) |
- |
650 |
|
- |
| Cl-6.1, Table-1(Mn) |
- |
650 |
|
- |
| Cl-6.1, Table-1(Mg) |
- |
650 |
|
- |
| Cl-6.1, Table-1(Cr) |
- |
650 |
|
- |
| Cl-6.1, Table-1(Ni) |
- |
650 |
|
- |
| Cl-6.1, Table-1(Zn) |
- |
650 |
|
- |
| Cl-6.1, Table-1(Pb) |
- |
650 |
|
- |
| Cl-6.1, Table-1(Sn) |
- |
650 |
|
- |
| Cl-6.1, Table-1(Ti) |
- |
650 |
|
- |
| Cl-6.1, Table-1(Others elements Each) |
- |
650 |
|
- |
| Cl-6.1, Table-1(Others elements Total) |
- |
650 |
|
- |
| Cl-6.1, Table-1(Aluminium) |
- |
650 |
|
- |
| Cl-6.2(The chemical analysis) |
- |
650 |
|
- |
| Cl. 6(Silicon) |
- |
650 |
|
- |
| Cl. 6(Iron) |
- |
650 |
|
- |
| Cl. 6(Copper) |
- |
650 |
|
- |
| Cl. 6(Manganese) |
- |
650 |
|
- |
| Cl. 6(Magnesium) |
- |
650 |
|
- |
| Cl. 6(Chromium) |
- |
650 |
|
- |
| Cl. 6(Nickel) |
- |
650 |
|
- |
| Cl. 6(Zinc) |
- |
650 |
|
- |
| Cl. 6(Lead) |
- |
650 |
|
- |
| Cl. 6(Tin) |
- |
650 |
|
- |
| Cl. 6(Titanium) |
- |
650 |
|
- |
| Cl. 6(Others Element Each) |
- |
650 |
|
- |
| Cl. 6(Others Element Total) |
- |
650 |
|
- |
| Cl. 6(Aluminium) |
- |
650 |
|
- |
| Cl. 6(Silver) |
- |
650 |
|
- |
| Cl. 6(Zirconium) |
- |
650 |
|
- |
| Cl. 6(Titanium+Zirconium) |
- |
650 |
|
- |
| Cl. 6(Antimony) |
- |
650 |
|
- |
| Cl. 6(Cobalt) |
- |
650 |
|
- |
| Cl. 6(Antimony+Cobalt) |
- |
650 |
|
- |
| Cl. 6(Beryllium) |
- |
650 |
|
- |
| Cl-7.1, Table-2(Sand-Cast Alloys- Tensile Strength) |
- |
400 |
|
- |
| Cl-7.1, Table-2(Sand-Cast Alloys- Proof Stress) |
- |
2500 |
|
- |
| Cl-7.1, Table-2(Sand-Cast Alloys- Brinell Hardness HBW) |
- |
400 |
|
- |
| Cl-7.1, Table-2(Sand-Cast Alloys- Elongation) |
- |
400 |
|
- |
| Cl-7.1, Table-3(Chill Cast Alloys- Tensile Strength) |
- |
400 |
|
- |
| Cl-7.1, Table-3(Chill Cast Alloys- Proof Stress) |
- |
2500 |
|
- |
| Cl-7.1, Table-3(Chill Cast Alloys- Elongation) |
- |
400 |
|
- |
| Cl-7.1, Table-3(Chill Cast Alloys- Brinell Hardness HBW) |
- |
400 |
|
- |
| Cl-7.1, Table-4(Investment-Cast Alloys- Tensile Strength) |
- |
400 |
|
- |
| Cl-7.1, Table-4(Investment-Cast Alloys- Proof Stress) |
- |
2500 |
|
- |
| Cl-7.1, Table-4(Investment-Cast Alloys- Elongation) |
- |
400 |
|
- |
| Cl-7.1, Table-4(Investment-Cast Alloys-Brinell Hardness) |
- |
400 |
|
- |
| Cl-7.2(Tensile Tests) |
- |
400 |
|
- |
| Cl-7.3(Test Pieces) |
- |
1500 |
|
- |
| Cl-7.4(Hardness) |
- |
400 |
|
- |
| Cl-8(Freedom from Defects) |
- |
2500 |
|
- |
| Cl-13(Marking) |
- |
500 |
|
- |
| 10(Pressure Test) |
- |
1000 |
|
- |
| Cl-11(RETEST) |
- |
7450 |
|
- |
|
28 Oct, 2028 |
- Complete For:
AlSi12(b), AlSi12(Fe), AlSi7Mg, AlSi7Mg0.3, AlSi7Mg0.3Ti, AlSi5Cu3Mn(a), AlSi5Cu3Mn(b), AlSi5Cu3Mn(c), AlSi5Cu4, AlSi5Cu1Mg, AlSi8Cu3, AlSi9Cu3(Fe), AlSi9Cu3(Fe)(Zn), AlSi11Cu2(Fe), AlSi11Cu3(Fe), AlSi10Cu, AlSi12Cu(b), AlSi12Cu(Fe) |
| 15 |
IS 210 (2009) |
Grey iron castings - Specification (First Revision) |
- |
3700 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 7.1(WORKMANSHIP AND FINISH) |
- |
500 |
|
- |
| 10.1(FREEDOM FROM DEFECTS) |
- |
500 |
|
- |
| 13(SIZE OF TEST BARS-Diameter) |
- |
500 |
|
- |
| 13(SIZE OF TEST BARS-Length) |
- |
500 |
|
- |
| 15, Table 3(TENSIL.E TEST- IS 1608 Part1 ) |
- |
400 |
|
- |
| 16, Table 3(Hardness Test) |
- |
400 |
|
- |
| 17,Annex B(TRANSVERSE TEST) |
- |
1000 |
|
- |
| 18(HYDROSTATIC TEST) |
- |
1000 |
|
- |
| 10.2(FREEDOM FROM DEFECTS) |
- |
500 |
|
- |
| 7.1(WORKMANSHIP AND FINISH) |
- |
500 |
|
- |
| 10.1(FREEDOM FROM DEFECTS) |
- |
500 |
|
- |
| 10.2(FREEDOM FROM DEFECTS) |
- |
500 |
|
- |
| 13(SIZE OF TEST BARS-Diameter) |
- |
500 |
|
- |
| 13(SIZE OF TEST BARS-Length) |
- |
500 |
|
- |
| 15, Table 3(TENSIL.E TEST- IS 1608 Part1 ) |
- |
400 |
|
- |
| 16, Table 3(Hardness Test) |
- |
400 |
|
- |
| 17,Annex B(TRANSVERSE TEST) |
- |
1000 |
|
- |
| 18(HYDROSTATIC TEST) |
- |
1000 |
|
- |
| 9(IS 7754) |
- |
0 |
|
- |
| 9(IS 7754) |
- |
0 |
|
- |
| 9(Microstructure) |
- |
1500 |
|
- |
| 21(Marking) |
- |
500 |
|
- |
| 9(Microstructure) |
- |
1500 |
|
- |
| 7.2(Casting dimensions) |
- |
500 |
|
- |
| 6(Chemical Composition(chemical
composition shall be as agreed to between the
purchaser and the manufacturer.)) |
- |
275 |
|
- |
| 6(Chemical Composition(chemical
composition shall be as agreed to between the
purchaser and the manufacturer.)) |
- |
1650 |
|
- |
| Cl-6(Phosprorus (P) - IS 12308 ( P-5)) |
- |
250 |
|
- |
|
28 Oct, 2028 |
- - |
| 16 |
IS 996 (2025) |
SINGLE PHASE ac INDUCTION MOTORS FOR GENERAL PURPOSE (Fouth Revision) |
- |
4600 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl-7(Dimensions) |
- |
0 |
|
Rs.4600/- |
| Cl-9.1(Mounting) |
- |
0 |
|
Rs.4600/- |
| Cl-9.2(Terminal Box) |
- |
0 |
|
Rs.4600/- |
| Cl-9.3(Mounting Constructions) |
- |
0 |
|
Rs.4600/- |
| Cl-9.3(Mounting Constructions) |
- |
0 |
|
Rs.4600/- |
| Cl-9.4(Constructional Features) |
- |
0 |
|
Rs.4600/- |
| Cl-9.5(Earthing) |
- |
0 |
|
Rs.4600/- |
| Cl-10.1(Enclosures) |
- |
0 |
|
Rs.4600/- |
| Cl-12.1(Torques) |
- |
0 |
|
Rs.4600/- |
| Cl-12.1.2(Momentary overload test) |
- |
0 |
|
Rs.4600/- |
| Cl-12.2(Temperature Rise) |
- |
0 |
|
Rs.4600/- |
| Cl-12.3(Short Time Rating) |
- |
0 |
|
Rs.4600/- |
| Cl-12.4(Method of Testing) |
- |
0 |
|
Rs.4600/- |
| Cl-12.5(Performance Values) |
- |
0 |
|
Rs.4600/- |
| Cl-12.6(Limits of Vibration Severity) |
- |
0 |
|
Rs.4600/- |
| Cl-12.7(Insulation Resistance) |
- |
0 |
|
Rs.4600/- |
| Cl-13.1(High Voltage Values) |
- |
0 |
|
Rs.4600/- |
| Cl-13.2(Moisture Proofness) |
- |
0 |
|
Rs.4600/- |
| Cl-13.3(Leakage Current) |
- |
0 |
|
Rs.4600/- |
| Cl-14(Winding Resistance Measurement) |
- |
0 |
|
Rs.4600/- |
| Cl-15(REDUCED VOLTAGE RUNNING UP TEST AT NO LOAD) |
- |
0 |
|
Rs.4600/- |
| Cl-16(NOISE LEVEL) |
- |
0 |
|
Rs.4600/- |
| Cl-17(OVER SPEED TEST) |
- |
0 |
|
Rs.4600/- |
| Cl-18(TERMINAL MARKING) |
- |
0 |
|
Rs.4600/- |
| Cl-12.1.1(Test for torues at rated voltage and frequency) |
- |
0 |
|
Rs.4600/- |
| Cl-12.1.1(Pull up Torque at rated voltage and frequency) |
- |
0 |
|
Rs.4600/- |
| Cl-12.1.1(Test for breakaway starting current at rated voltage and frequency) |
- |
0 |
|
Rs.4600/- |
| Cl-12.1.2(Breakaway (starting) torque at rated voltage and frequency) |
- |
0 |
|
Rs.4600/- |
| Cl-12.5.1(Test for full-load performance at rated voltage and frequency) |
- |
0 |
|
Rs.4600/- |
| Cl-21.5(Acceptance Tests) |
- |
0 |
|
Rs.4600/- |
|
28 Oct, 2028 |
- - |
| 17 |
IS 12615 (2018) |
Line operated three phase AC motors (IE Code) "Efficiency classes and performance specification" (Third Revision) |
- |
4400 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 15.2(Rating) |
- |
0 |
|
Rs.4400/- 3.7 kW,
Rs.4950/- 3.7 kW to 7.5 kW,
Rs.6100/- 7.5 kW to 11.0 kW,
Rs.6500/- 11.0 kW to 15.0 kW,
Rs.8900/- 15.0 kW to 20.0 kW,
Rs.10000/- 20.0 kW to 25.0 kW,
Rs.13600/- 25.0 kW to 30.0 kW
Rs.15100/- 30.0 kW to 37.0 kW. |
| 18.3(BIS Certification Marking
) |
- |
0 |
|
Rs.4400/- 3.7 kW,
Rs.4950/- 3.7 kW to 7.5 kW,
Rs.6100/- 7.5 kW to 11.0 kW,
Rs.6500/- 11.0 kW to 15.0 kW,
Rs.8900/- 15.0 kW to 20.0 kW,
Rs.10000/- 20.0 kW to 25.0 kW,
Rs.13600/- 25.0 kW to 30.0 kW
Rs.15100/- 30.0 kW to 37.0 kW. |
| 15.3.2(Marking) |
- |
0 |
|
Rs.4400/- 3.7 kW,
Rs.4950/- 3.7 kW to 7.5 kW,
Rs.6100/- 7.5 kW to 11.0 kW,
Rs.6500/- 11.0 kW to 15.0 kW,
Rs.8900/- 15.0 kW to 20.0 kW,
Rs.10000/- 20.0 kW to 25.0 kW,
Rs.13600/- 25.0 kW to 30.0 kW
Rs.15100/- 30.0 kW to 37.0 kW. |
| 8.0(Earthing) |
- |
0 |
|
Rs.4400/- 3.7 kW,
Rs.4950/- 3.7 kW to 7.5 kW,
Rs.6100/- 7.5 kW to 11.0 kW,
Rs.6500/- 11.0 kW to 15.0 kW,
Rs.8900/- 15.0 kW to 20.0 kW,
Rs.10000/- 20.0 kW to 25.0 kW,
Rs.13600/- 25.0 kW to 30.0 kW
Rs.15100/- 30.0 kW to 37.0 kW. |
| 9.0(Terminal Marking) |
- |
0 |
|
Rs.4400/- 3.7 kW,
Rs.4950/- 3.7 kW to 7.5 kW,
Rs.6100/- 7.5 kW to 11.0 kW,
Rs.6500/- 11.0 kW to 15.0 kW,
Rs.8900/- 15.0 kW to 20.0 kW,
Rs.10000/- 20.0 kW to 25.0 kW,
Rs.13600/- 25.0 kW to 30.0 kW
Rs.15100/- 30.0 kW to 37.0 kW. |
| 11.0(DUTY AND RATING) |
- |
0 |
|
Rs.4400/- 3.7 kW,
Rs.4950/- 3.7 kW to 7.5 kW,
Rs.6100/- 7.5 kW to 11.0 kW,
Rs.6500/- 11.0 kW to 15.0 kW,
Rs.8900/- 15.0 kW to 20.0 kW,
Rs.10000/- 20.0 kW to 25.0 kW,
Rs.13600/- 25.0 kW to 30.0 kW
Rs.15100/- 30.0 kW to 37.0 kW. |
| 18.3(Marking) |
- |
0 |
|
Rs.4400/- 3.7 kW,
Rs.4950/- 3.7 kW to 7.5 kW,
Rs.6100/- 7.5 kW to 11.0 kW,
Rs.6500/- 11.0 kW to 15.0 kW,
Rs.8900/- 15.0 kW to 20.0 kW,
Rs.10000/- 20.0 kW to 25.0 kW,
Rs.13600/- 25.0 kW to 30.0 kW
Rs.15100/- 30.0 kW to 37.0 kW. |
| 16.2.1(Dimensions) |
- |
0 |
|
Rs.4400/- 3.7 kW,
Rs.4950/- 3.7 kW to 7.5 kW,
Rs.6100/- 7.5 kW to 11.0 kW,
Rs.6500/- 11.0 kW to 15.0 kW,
Rs.8900/- 15.0 kW to 20.0 kW,
Rs.10000/- 20.0 kW to 25.0 kW,
Rs.13600/- 25.0 kW to 30.0 kW
Rs.15100/- 30.0 kW to 37.0 kW. |
| 16.1.1(Insulation Resistance Test) |
- |
0 |
|
Rs.4400/- 3.7 kW,
Rs.4950/- 3.7 kW to 7.5 kW,
Rs.6100/- 7.5 kW to 11.0 kW,
Rs.6500/- 11.0 kW to 15.0 kW,
Rs.8900/- 15.0 kW to 20.0 kW,
Rs.10000/- 20.0 kW to 25.0 kW,
Rs.13600/- 25.0 kW to 30.0 kW
Rs.15100/- 30.0 kW to 37.0 kW. |
| 16.1.2(Measurement of Resistance of Windings of Stator) |
- |
0 |
|
Rs.4400/- 3.7 kW,
Rs.4950/- 3.7 kW to 7.5 kW,
Rs.6100/- 7.5 kW to 11.0 kW,
Rs.6500/- 11.0 kW to 15.0 kW,
Rs.8900/- 15.0 kW to 20.0 kW,
Rs.10000/- 20.0 kW to 25.0 kW,
Rs.13600/- 25.0 kW to 30.0 kW
Rs.15100/- 30.0 kW to 37.0 kW. |
| 16.1.3(No Load Test) |
- |
0 |
|
Rs.4400/- 3.7 kW,
Rs.4950/- 3.7 kW to 7.5 kW,
Rs.6100/- 7.5 kW to 11.0 kW,
Rs.6500/- 11.0 kW to 15.0 kW,
Rs.8900/- 15.0 kW to 20.0 kW,
Rs.10000/- 20.0 kW to 25.0 kW,
Rs.13600/- 25.0 kW to 30.0 kW
Rs.15100/- 30.0 kW to 37.0 kW. |
| 16.1.4(Locked Rotor Readings of Voltage, Current and Power Input at a Suitable Reduced Voltage) |
- |
0 |
|
Rs.4400/- 3.7 kW,
Rs.4950/- 3.7 kW to 7.5 kW,
Rs.6100/- 7.5 kW to 11.0 kW,
Rs.6500/- 11.0 kW to 15.0 kW,
Rs.8900/- 15.0 kW to 20.0 kW,
Rs.10000/- 20.0 kW to 25.0 kW,
Rs.13600/- 25.0 kW to 30.0 kW
Rs.15100/- 30.0 kW to 37.0 kW. |
| 16.1.5(5 Reduced Voltage Running up Test at no-load (for squirrel cage motor up to 37 kW only)) |
- |
0 |
|
Rs.4400/- 3.7 kW,
Rs.4950/- 3.7 kW to 7.5 kW,
Rs.6100/- 7.5 kW to 11.0 kW,
Rs.6500/- 11.0 kW to 15.0 kW,
Rs.8900/- 15.0 kW to 20.0 kW,
Rs.10000/- 20.0 kW to 25.0 kW,
Rs.13600/- 25.0 kW to 30.0 kW
Rs.15100/- 30.0 kW to 37.0 kW. |
| 16.1.6(High Voltage Test) |
- |
0 |
|
Rs.4400/- 3.7 kW,
Rs.4950/- 3.7 kW to 7.5 kW,
Rs.6100/- 7.5 kW to 11.0 kW,
Rs.6500/- 11.0 kW to 15.0 kW,
Rs.8900/- 15.0 kW to 20.0 kW,
Rs.10000/- 20.0 kW to 25.0 kW,
Rs.13600/- 25.0 kW to 30.0 kW
Rs.15100/- 30.0 kW to 37.0 kW. |
| 16.2.2(Locked Rotor Test) |
- |
0 |
|
Rs.4400/- 3.7 kW,
Rs.4950/- 3.7 kW to 7.5 kW,
Rs.6100/- 7.5 kW to 11.0 kW,
Rs.6500/- 11.0 kW to 15.0 kW,
Rs.8900/- 15.0 kW to 20.0 kW,
Rs.10000/- 20.0 kW to 25.0 kW,
Rs.13600/- 25.0 kW to 30.0 kW
Rs.15100/- 30.0 kW to 37.0 kW. |
| 16.2.2.1(Locked Rotor Test) |
- |
0 |
|
Rs.4400/- 3.7 kW,
Rs.4950/- 3.7 kW to 7.5 kW,
Rs.6100/- 7.5 kW to 11.0 kW,
Rs.6500/- 11.0 kW to 15.0 kW,
Rs.8900/- 15.0 kW to 20.0 kW,
Rs.10000/- 20.0 kW to 25.0 kW,
Rs.13600/- 25.0 kW to 30.0 kW
Rs.15100/- 30.0 kW to 37.0 kW. |
| 16.2.2.2(Locked Rotor Test) |
- |
0 |
|
Rs.4400/- 3.7 kW,
Rs.4950/- 3.7 kW to 7.5 kW,
Rs.6100/- 7.5 kW to 11.0 kW,
Rs.6500/- 11.0 kW to 15.0 kW,
Rs.8900/- 15.0 kW to 20.0 kW,
Rs.10000/- 20.0 kW to 25.0 kW,
Rs.13600/- 25.0 kW to 30.0 kW
Rs.15100/- 30.0 kW to 37.0 kW. |
| 16.2.2.2.1(Locked Rotor Test) |
- |
0 |
|
Rs.4400/- 3.7 kW,
Rs.4950/- 3.7 kW to 7.5 kW,
Rs.6100/- 7.5 kW to 11.0 kW,
Rs.6500/- 11.0 kW to 15.0 kW,
Rs.8900/- 15.0 kW to 20.0 kW,
Rs.10000/- 20.0 kW to 25.0 kW,
Rs.13600/- 25.0 kW to 30.0 kW
Rs.15100/- 30.0 kW to 37.0 kW. |
| 16.2.2.3(Determination of starting characteristics
-locked rotor current) |
- |
0 |
|
Rs.4400/- 3.7 kW,
Rs.4950/- 3.7 kW to 7.5 kW,
Rs.6100/- 7.5 kW to 11.0 kW,
Rs.6500/- 11.0 kW to 15.0 kW,
Rs.8900/- 15.0 kW to 20.0 kW,
Rs.10000/- 20.0 kW to 25.0 kW,
Rs.13600/- 25.0 kW to 30.0 kW
Rs.15100/- 30.0 kW to 37.0 kW. |
| 16.2.2.3.1(Direct proportion method) |
- |
0 |
|
Rs.4400/- 3.7 kW,
Rs.4950/- 3.7 kW to 7.5 kW,
Rs.6100/- 7.5 kW to 11.0 kW,
Rs.6500/- 11.0 kW to 15.0 kW,
Rs.8900/- 15.0 kW to 20.0 kW,
Rs.10000/- 20.0 kW to 25.0 kW,
Rs.13600/- 25.0 kW to 30.0 kW
Rs.15100/- 30.0 kW to 37.0 kW. |
| 16.2.3(Full Load Test to Determine Efficiency, Power Factor and Slip) |
- |
0 |
|
Rs.4400/- 3.7 kW,
Rs.4950/- 3.7 kW to 7.5 kW,
Rs.6100/- 7.5 kW to 11.0 kW,
Rs.6500/- 11.0 kW to 15.0 kW,
Rs.8900/- 15.0 kW to 20.0 kW,
Rs.10000/- 20.0 kW to 25.0 kW,
Rs.13600/- 25.0 kW to 30.0 kW
Rs.15100/- 30.0 kW to 37.0 kW. |
| 16.2.4(Temperature Rise Test) |
- |
0 |
|
Rs.4400/- 3.7 kW,
Rs.4950/- 3.7 kW to 7.5 kW,
Rs.6100/- 7.5 kW to 11.0 kW,
Rs.6500/- 11.0 kW to 15.0 kW,
Rs.8900/- 15.0 kW to 20.0 kW,
Rs.10000/- 20.0 kW to 25.0 kW,
Rs.13600/- 25.0 kW to 30.0 kW
Rs.15100/- 30.0 kW to 37.0 kW. |
| 16.2.5(Momentary Overload Test) |
- |
0 |
|
Rs.4400/- 3.7 kW,
Rs.4950/- 3.7 kW to 7.5 kW,
Rs.6100/- 7.5 kW to 11.0 kW,
Rs.6500/- 11.0 kW to 15.0 kW,
Rs.8900/- 15.0 kW to 20.0 kW,
Rs.10000/- 20.0 kW to 25.0 kW,
Rs.13600/- 25.0 kW to 30.0 kW
Rs.15100/- 30.0 kW to 37.0 kW. |
| 16.3.1( Test for Vibration Severity of Motor) |
- |
2400 |
|
Rs.4400/- 3.7 kW,
Rs.4950/- 3.7 kW to 7.5 kW,
Rs.6100/- 7.5 kW to 11.0 kW,
Rs.6500/- 11.0 kW to 15.0 kW,
Rs.8900/- 15.0 kW to 20.0 kW,
Rs.10000/- 20.0 kW to 25.0 kW,
Rs.13600/- 25.0 kW to 30.0 kW
Rs.15100/- 30.0 kW to 37.0 kW. |
| 16.3.2( Test for Noise Levels of Motor) |
- |
1100 |
|
Rs.4400/- 3.7 kW,
Rs.4950/- 3.7 kW to 7.5 kW,
Rs.6100/- 7.5 kW to 11.0 kW,
Rs.6500/- 11.0 kW to 15.0 kW,
Rs.8900/- 15.0 kW to 20.0 kW,
Rs.10000/- 20.0 kW to 25.0 kW,
Rs.13600/- 25.0 kW to 30.0 kW
Rs.15100/- 30.0 kW to 37.0 kW. |
| 16.3.3( Test for Degree of Protection by Enclosure) |
- |
10000 |
|
Rs.4400/- 3.7 kW,
Rs.4950/- 3.7 kW to 7.5 kW,
Rs.6100/- 7.5 kW to 11.0 kW,
Rs.6500/- 11.0 kW to 15.0 kW,
Rs.8900/- 15.0 kW to 20.0 kW,
Rs.10000/- 20.0 kW to 25.0 kW,
Rs.13600/- 25.0 kW to 30.0 kW
Rs.15100/- 30.0 kW to 37.0 kW. |
| 16.3.4(Over Speed Test) |
- |
2400 |
|
Rs.4400/- 3.7 kW,
Rs.4950/- 3.7 kW to 7.5 kW,
Rs.6100/- 7.5 kW to 11.0 kW,
Rs.6500/- 11.0 kW to 15.0 kW,
Rs.8900/- 15.0 kW to 20.0 kW,
Rs.10000/- 20.0 kW to 25.0 kW,
Rs.13600/- 25.0 kW to 30.0 kW
Rs.15100/- 30.0 kW to 37.0 kW. |
| 16.3.5( Temperature Rise Test at Limiting Values of
Voltage and Frequency Variation) |
- |
2400 |
|
Rs.4400/- 3.7 kW,
Rs.4950/- 3.7 kW to 7.5 kW,
Rs.6100/- 7.5 kW to 11.0 kW,
Rs.6500/- 11.0 kW to 15.0 kW,
Rs.8900/- 15.0 kW to 20.0 kW,
Rs.10000/- 20.0 kW to 25.0 kW,
Rs.13600/- 25.0 kW to 30.0 kW
Rs.15100/- 30.0 kW to 37.0 kW. |
| 15.2(Rating) |
- |
0 |
|
Rs.4400/- 3.7 kW,
Rs.4950/- 3.7 kW to 7.5 kW,
Rs.6100/- 7.5 kW to 11.0 kW,
Rs.6500/- 11.0 kW to 15.0 kW,
Rs.8900/- 15.0 kW to 20.0 kW,
Rs.10000/- 20.0 kW to 25.0 kW,
Rs.13600/- 25.0 kW to 30.0 kW
Rs.15100/- 30.0 kW to 37.0 kW. |
| 18.3(BIS Certification Marking
) |
- |
0 |
|
Rs.4400/- 3.7 kW,
Rs.4950/- 3.7 kW to 7.5 kW,
Rs.6100/- 7.5 kW to 11.0 kW,
Rs.6500/- 11.0 kW to 15.0 kW,
Rs.8900/- 15.0 kW to 20.0 kW,
Rs.10000/- 20.0 kW to 25.0 kW,
Rs.13600/- 25.0 kW to 30.0 kW
Rs.15100/- 30.0 kW to 37.0 kW. |
| 15.3.2(Marking) |
- |
0 |
|
Rs.4400/- 3.7 kW,
Rs.4950/- 3.7 kW to 7.5 kW,
Rs.6100/- 7.5 kW to 11.0 kW,
Rs.6500/- 11.0 kW to 15.0 kW,
Rs.8900/- 15.0 kW to 20.0 kW,
Rs.10000/- 20.0 kW to 25.0 kW,
Rs.13600/- 25.0 kW to 30.0 kW
Rs.15100/- 30.0 kW to 37.0 kW. |
| 8.0(Earthing) |
- |
0 |
|
Rs.4400/- 3.7 kW,
Rs.4950/- 3.7 kW to 7.5 kW,
Rs.6100/- 7.5 kW to 11.0 kW,
Rs.6500/- 11.0 kW to 15.0 kW,
Rs.8900/- 15.0 kW to 20.0 kW,
Rs.10000/- 20.0 kW to 25.0 kW,
Rs.13600/- 25.0 kW to 30.0 kW
Rs.15100/- 30.0 kW to 37.0 kW. |
| 9.0(Terminal Marking) |
- |
0 |
|
Rs.4400/- 3.7 kW,
Rs.4950/- 3.7 kW to 7.5 kW,
Rs.6100/- 7.5 kW to 11.0 kW,
Rs.6500/- 11.0 kW to 15.0 kW,
Rs.8900/- 15.0 kW to 20.0 kW,
Rs.10000/- 20.0 kW to 25.0 kW,
Rs.13600/- 25.0 kW to 30.0 kW
Rs.15100/- 30.0 kW to 37.0 kW. |
| 11.0(DUTY AND RATING) |
- |
0 |
|
Rs.4400/- 3.7 kW,
Rs.4950/- 3.7 kW to 7.5 kW,
Rs.6100/- 7.5 kW to 11.0 kW,
Rs.6500/- 11.0 kW to 15.0 kW,
Rs.8900/- 15.0 kW to 20.0 kW,
Rs.10000/- 20.0 kW to 25.0 kW,
Rs.13600/- 25.0 kW to 30.0 kW
Rs.15100/- 30.0 kW to 37.0 kW. |
| 18.3(Marking) |
- |
0 |
|
Rs.4400/- 3.7 kW,
Rs.4950/- 3.7 kW to 7.5 kW,
Rs.6100/- 7.5 kW to 11.0 kW,
Rs.6500/- 11.0 kW to 15.0 kW,
Rs.8900/- 15.0 kW to 20.0 kW,
Rs.10000/- 20.0 kW to 25.0 kW,
Rs.13600/- 25.0 kW to 30.0 kW
Rs.15100/- 30.0 kW to 37.0 kW. |
| 16.2.1(Dimensions) |
- |
0 |
|
Rs.4400/- 3.7 kW,
Rs.4950/- 3.7 kW to 7.5 kW,
Rs.6100/- 7.5 kW to 11.0 kW,
Rs.6500/- 11.0 kW to 15.0 kW,
Rs.8900/- 15.0 kW to 20.0 kW,
Rs.10000/- 20.0 kW to 25.0 kW,
Rs.13600/- 25.0 kW to 30.0 kW
Rs.15100/- 30.0 kW to 37.0 kW. |
| 16.1.1(Insulation Resistance Test) |
- |
0 |
|
Rs.4400/- 3.7 kW,
Rs.4950/- 3.7 kW to 7.5 kW,
Rs.6100/- 7.5 kW to 11.0 kW,
Rs.6500/- 11.0 kW to 15.0 kW,
Rs.8900/- 15.0 kW to 20.0 kW,
Rs.10000/- 20.0 kW to 25.0 kW,
Rs.13600/- 25.0 kW to 30.0 kW
Rs.15100/- 30.0 kW to 37.0 kW. |
| 16.1.2(Measurement of Resistance of Windings of Stator) |
- |
0 |
|
Rs.4400/- 3.7 kW,
Rs.4950/- 3.7 kW to 7.5 kW,
Rs.6100/- 7.5 kW to 11.0 kW,
Rs.6500/- 11.0 kW to 15.0 kW,
Rs.8900/- 15.0 kW to 20.0 kW,
Rs.10000/- 20.0 kW to 25.0 kW,
Rs.13600/- 25.0 kW to 30.0 kW
Rs.15100/- 30.0 kW to 37.0 kW. |
| 16.1.3(No Load Test) |
- |
0 |
|
Rs.4400/- 3.7 kW,
Rs.4950/- 3.7 kW to 7.5 kW,
Rs.6100/- 7.5 kW to 11.0 kW,
Rs.6500/- 11.0 kW to 15.0 kW,
Rs.8900/- 15.0 kW to 20.0 kW,
Rs.10000/- 20.0 kW to 25.0 kW,
Rs.13600/- 25.0 kW to 30.0 kW
Rs.15100/- 30.0 kW to 37.0 kW. |
| 16.1.4(Locked Rotor Readings of Voltage, Current and Power Input at a Suitable Reduced Voltage) |
- |
0 |
|
Rs.4400/- 3.7 kW,
Rs.4950/- 3.7 kW to 7.5 kW,
Rs.6100/- 7.5 kW to 11.0 kW,
Rs.6500/- 11.0 kW to 15.0 kW,
Rs.8900/- 15.0 kW to 20.0 kW,
Rs.10000/- 20.0 kW to 25.0 kW,
Rs.13600/- 25.0 kW to 30.0 kW
Rs.15100/- 30.0 kW to 37.0 kW. |
| 16.1.5(5 Reduced Voltage Running up Test at no-load (for squirrel cage motor up to 37 kW only)) |
- |
0 |
|
Rs.4400/- 3.7 kW,
Rs.4950/- 3.7 kW to 7.5 kW,
Rs.6100/- 7.5 kW to 11.0 kW,
Rs.6500/- 11.0 kW to 15.0 kW,
Rs.8900/- 15.0 kW to 20.0 kW,
Rs.10000/- 20.0 kW to 25.0 kW,
Rs.13600/- 25.0 kW to 30.0 kW
Rs.15100/- 30.0 kW to 37.0 kW. |
| 16.1.6(High Voltage Test) |
- |
0 |
|
Rs.4400/- 3.7 kW,
Rs.4950/- 3.7 kW to 7.5 kW,
Rs.6100/- 7.5 kW to 11.0 kW,
Rs.6500/- 11.0 kW to 15.0 kW,
Rs.8900/- 15.0 kW to 20.0 kW,
Rs.10000/- 20.0 kW to 25.0 kW,
Rs.13600/- 25.0 kW to 30.0 kW
Rs.15100/- 30.0 kW to 37.0 kW. |
| 16.2.2(Locked Rotor Test) |
- |
0 |
|
Rs.4400/- 3.7 kW,
Rs.4950/- 3.7 kW to 7.5 kW,
Rs.6100/- 7.5 kW to 11.0 kW,
Rs.6500/- 11.0 kW to 15.0 kW,
Rs.8900/- 15.0 kW to 20.0 kW,
Rs.10000/- 20.0 kW to 25.0 kW,
Rs.13600/- 25.0 kW to 30.0 kW
Rs.15100/- 30.0 kW to 37.0 kW. |
| 16.2.2.1(Locked Rotor Test) |
- |
0 |
|
Rs.4400/- 3.7 kW,
Rs.4950/- 3.7 kW to 7.5 kW,
Rs.6100/- 7.5 kW to 11.0 kW,
Rs.6500/- 11.0 kW to 15.0 kW,
Rs.8900/- 15.0 kW to 20.0 kW,
Rs.10000/- 20.0 kW to 25.0 kW,
Rs.13600/- 25.0 kW to 30.0 kW
Rs.15100/- 30.0 kW to 37.0 kW. |
| 16.2.2.2(Locked Rotor Test) |
- |
0 |
|
Rs.4400/- 3.7 kW,
Rs.4950/- 3.7 kW to 7.5 kW,
Rs.6100/- 7.5 kW to 11.0 kW,
Rs.6500/- 11.0 kW to 15.0 kW,
Rs.8900/- 15.0 kW to 20.0 kW,
Rs.10000/- 20.0 kW to 25.0 kW,
Rs.13600/- 25.0 kW to 30.0 kW
Rs.15100/- 30.0 kW to 37.0 kW. |
| 16.2.2.2.1(Locked Rotor Test) |
- |
0 |
|
Rs.4400/- 3.7 kW,
Rs.4950/- 3.7 kW to 7.5 kW,
Rs.6100/- 7.5 kW to 11.0 kW,
Rs.6500/- 11.0 kW to 15.0 kW,
Rs.8900/- 15.0 kW to 20.0 kW,
Rs.10000/- 20.0 kW to 25.0 kW,
Rs.13600/- 25.0 kW to 30.0 kW
Rs.15100/- 30.0 kW to 37.0 kW. |
| 16.2.2.3(Determination of starting characteristics
-locked rotor current) |
- |
0 |
|
Rs.4400/- 3.7 kW,
Rs.4950/- 3.7 kW to 7.5 kW,
Rs.6100/- 7.5 kW to 11.0 kW,
Rs.6500/- 11.0 kW to 15.0 kW,
Rs.8900/- 15.0 kW to 20.0 kW,
Rs.10000/- 20.0 kW to 25.0 kW,
Rs.13600/- 25.0 kW to 30.0 kW
Rs.15100/- 30.0 kW to 37.0 kW. |
| 16.2.2.3.1(Direct proportion method) |
- |
0 |
|
Rs.4400/- 3.7 kW,
Rs.4950/- 3.7 kW to 7.5 kW,
Rs.6100/- 7.5 kW to 11.0 kW,
Rs.6500/- 11.0 kW to 15.0 kW,
Rs.8900/- 15.0 kW to 20.0 kW,
Rs.10000/- 20.0 kW to 25.0 kW,
Rs.13600/- 25.0 kW to 30.0 kW
Rs.15100/- 30.0 kW to 37.0 kW. |
| 16.2.3(Full Load Test to Determine Efficiency, Power Factor and Slip) |
- |
0 |
|
Rs.4400/- 3.7 kW,
Rs.4950/- 3.7 kW to 7.5 kW,
Rs.6100/- 7.5 kW to 11.0 kW,
Rs.6500/- 11.0 kW to 15.0 kW,
Rs.8900/- 15.0 kW to 20.0 kW,
Rs.10000/- 20.0 kW to 25.0 kW,
Rs.13600/- 25.0 kW to 30.0 kW
Rs.15100/- 30.0 kW to 37.0 kW. |
| 16.2.4(Temperature Rise Test) |
- |
0 |
|
Rs.4400/- 3.7 kW,
Rs.4950/- 3.7 kW to 7.5 kW,
Rs.6100/- 7.5 kW to 11.0 kW,
Rs.6500/- 11.0 kW to 15.0 kW,
Rs.8900/- 15.0 kW to 20.0 kW,
Rs.10000/- 20.0 kW to 25.0 kW,
Rs.13600/- 25.0 kW to 30.0 kW
Rs.15100/- 30.0 kW to 37.0 kW. |
| 16.2.5(Momentary Overload Test) |
- |
0 |
|
Rs.4400/- 3.7 kW,
Rs.4950/- 3.7 kW to 7.5 kW,
Rs.6100/- 7.5 kW to 11.0 kW,
Rs.6500/- 11.0 kW to 15.0 kW,
Rs.8900/- 15.0 kW to 20.0 kW,
Rs.10000/- 20.0 kW to 25.0 kW,
Rs.13600/- 25.0 kW to 30.0 kW
Rs.15100/- 30.0 kW to 37.0 kW. |
| 16.3.1( Test for Vibration Severity of Motor) |
- |
2400 |
|
Rs.4400/- 3.7 kW,
Rs.4950/- 3.7 kW to 7.5 kW,
Rs.6100/- 7.5 kW to 11.0 kW,
Rs.6500/- 11.0 kW to 15.0 kW,
Rs.8900/- 15.0 kW to 20.0 kW,
Rs.10000/- 20.0 kW to 25.0 kW,
Rs.13600/- 25.0 kW to 30.0 kW
Rs.15100/- 30.0 kW to 37.0 kW. |
| 16.3.2( Test for Noise Levels of Motor) |
- |
1100 |
|
Rs.4400/- 3.7 kW,
Rs.4950/- 3.7 kW to 7.5 kW,
Rs.6100/- 7.5 kW to 11.0 kW,
Rs.6500/- 11.0 kW to 15.0 kW,
Rs.8900/- 15.0 kW to 20.0 kW,
Rs.10000/- 20.0 kW to 25.0 kW,
Rs.13600/- 25.0 kW to 30.0 kW
Rs.15100/- 30.0 kW to 37.0 kW. |
| 16.3.3( Test for Degree of Protection by Enclosure) |
- |
10000 |
|
Rs.4400/- 3.7 kW,
Rs.4950/- 3.7 kW to 7.5 kW,
Rs.6100/- 7.5 kW to 11.0 kW,
Rs.6500/- 11.0 kW to 15.0 kW,
Rs.8900/- 15.0 kW to 20.0 kW,
Rs.10000/- 20.0 kW to 25.0 kW,
Rs.13600/- 25.0 kW to 30.0 kW
Rs.15100/- 30.0 kW to 37.0 kW. |
| 16.3.4(Over Speed Test) |
- |
2400 |
|
Rs.4400/- 3.7 kW,
Rs.4950/- 3.7 kW to 7.5 kW,
Rs.6100/- 7.5 kW to 11.0 kW,
Rs.6500/- 11.0 kW to 15.0 kW,
Rs.8900/- 15.0 kW to 20.0 kW,
Rs.10000/- 20.0 kW to 25.0 kW,
Rs.13600/- 25.0 kW to 30.0 kW
Rs.15100/- 30.0 kW to 37.0 kW. |
| 16.3.5( Temperature Rise Test at Limiting Values of
Voltage and Frequency Variation) |
- |
2400 |
|
Rs.4400/- 3.7 kW,
Rs.4950/- 3.7 kW to 7.5 kW,
Rs.6100/- 7.5 kW to 11.0 kW,
Rs.6500/- 11.0 kW to 15.0 kW,
Rs.8900/- 15.0 kW to 20.0 kW,
Rs.10000/- 20.0 kW to 25.0 kW,
Rs.13600/- 25.0 kW to 30.0 kW
Rs.15100/- 30.0 kW to 37.0 kW. |
| 12.2(Pull up torque) |
- |
0 |
|
Rs.4400/- 3.7 kW,
Rs.4950/- 3.7 kW to 7.5 kW,
Rs.6100/- 7.5 kW to 11.0 kW,
Rs.6500/- 11.0 kW to 15.0 kW,
Rs.8900/- 15.0 kW to 20.0 kW,
Rs.10000/- 20.0 kW to 25.0 kW,
Rs.13600/- 25.0 kW to 30.0 kW
Rs.15100/- 30.0 kW to 37.0 kW. |
| 6(Method of cooling) |
- |
0 |
|
Rs.4400/- 3.7 kW,
Rs.4950/- 3.7 kW to 7.5 kW,
Rs.6100/- 7.5 kW to 11.0 kW,
Rs.6500/- 11.0 kW to 15.0 kW,
Rs.8900/- 15.0 kW to 20.0 kW,
Rs.10000/- 20.0 kW to 25.0 kW,
Rs.13600/- 25.0 kW to 30.0 kW
Rs.15100/- 30.0 kW to 37.0 kW. |
| Cl. 16.3.5(Temperature rise test at limiting values of voltage and frequnancy variation) |
- |
2400 |
|
Rs.4400/- 3.7 kW,
Rs.4950/- 3.7 kW to 7.5 kW,
Rs.6100/- 7.5 kW to 11.0 kW,
Rs.6500/- 11.0 kW to 15.0 kW,
Rs.8900/- 15.0 kW to 20.0 kW,
Rs.10000/- 20.0 kW to 25.0 kW,
Rs.13600/- 25.0 kW to 30.0 kW
Rs.15100/- 30.0 kW to 37.0 kW. |
| Cl. 16.3.4(Over Speed test) |
- |
2400 |
|
Rs.4400/- 3.7 kW,
Rs.4950/- 3.7 kW to 7.5 kW,
Rs.6100/- 7.5 kW to 11.0 kW,
Rs.6500/- 11.0 kW to 15.0 kW,
Rs.8900/- 15.0 kW to 20.0 kW,
Rs.10000/- 20.0 kW to 25.0 kW,
Rs.13600/- 25.0 kW to 30.0 kW
Rs.15100/- 30.0 kW to 37.0 kW. |
| Cl. 16.3.3(Test for degree of protection by enclosure) |
- |
10000 |
|
Rs.4400/- 3.7 kW,
Rs.4950/- 3.7 kW to 7.5 kW,
Rs.6100/- 7.5 kW to 11.0 kW,
Rs.6500/- 11.0 kW to 15.0 kW,
Rs.8900/- 15.0 kW to 20.0 kW,
Rs.10000/- 20.0 kW to 25.0 kW,
Rs.13600/- 25.0 kW to 30.0 kW
Rs.15100/- 30.0 kW to 37.0 kW. |
| Cl. 16.3.2(Noise) |
- |
1100 |
|
Rs.4400/- 3.7 kW,
Rs.4950/- 3.7 kW to 7.5 kW,
Rs.6100/- 7.5 kW to 11.0 kW,
Rs.6500/- 11.0 kW to 15.0 kW,
Rs.8900/- 15.0 kW to 20.0 kW,
Rs.10000/- 20.0 kW to 25.0 kW,
Rs.13600/- 25.0 kW to 30.0 kW
Rs.15100/- 30.0 kW to 37.0 kW. |
| Cl. 16.3.1(Vibration test) |
- |
2400 |
|
Rs.4400/- 3.7 kW,
Rs.4950/- 3.7 kW to 7.5 kW,
Rs.6100/- 7.5 kW to 11.0 kW,
Rs.6500/- 11.0 kW to 15.0 kW,
Rs.8900/- 15.0 kW to 20.0 kW,
Rs.10000/- 20.0 kW to 25.0 kW,
Rs.13600/- 25.0 kW to 30.0 kW
Rs.15100/- 30.0 kW to 37.0 kW. |
| Cl. 11(Duty and Rating) |
- |
0 |
|
Rs.4400/- 3.7 kW,
Rs.4950/- 3.7 kW to 7.5 kW,
Rs.6100/- 7.5 kW to 11.0 kW,
Rs.6500/- 11.0 kW to 15.0 kW,
Rs.8900/- 15.0 kW to 20.0 kW,
Rs.10000/- 20.0 kW to 25.0 kW,
Rs.13600/- 25.0 kW to 30.0 kW
Rs.15100/- 30.0 kW to 37.0 kW. |
| Cl. 16.2.1(Dimensions) |
- |
0 |
|
Rs.4400/- 3.7 kW,
Rs.4950/- 3.7 kW to 7.5 kW,
Rs.6100/- 7.5 kW to 11.0 kW,
Rs.6500/- 11.0 kW to 15.0 kW,
Rs.8900/- 15.0 kW to 20.0 kW,
Rs.10000/- 20.0 kW to 25.0 kW,
Rs.13600/- 25.0 kW to 30.0 kW
Rs.15100/- 30.0 kW to 37.0 kW. |
| Cl. 16.1.6(High Voltage Test) |
- |
0 |
|
Rs.4400/- 3.7 kW,
Rs.4950/- 3.7 kW to 7.5 kW,
Rs.6100/- 7.5 kW to 11.0 kW,
Rs.6500/- 11.0 kW to 15.0 kW,
Rs.8900/- 15.0 kW to 20.0 kW,
Rs.10000/- 20.0 kW to 25.0 kW,
Rs.13600/- 25.0 kW to 30.0 kW
Rs.15100/- 30.0 kW to 37.0 kW. |
| Cl. 16.1.1(Insulation Resistance test) |
- |
0 |
|
Rs.4400/- 3.7 kW,
Rs.4950/- 3.7 kW to 7.5 kW,
Rs.6100/- 7.5 kW to 11.0 kW,
Rs.6500/- 11.0 kW to 15.0 kW,
Rs.8900/- 15.0 kW to 20.0 kW,
Rs.10000/- 20.0 kW to 25.0 kW,
Rs.13600/- 25.0 kW to 30.0 kW
Rs.15100/- 30.0 kW to 37.0 kW. |
| Cl. 16.2.5(Momentary overload test) |
- |
0 |
|
Rs.4400/- 3.7 kW,
Rs.4950/- 3.7 kW to 7.5 kW,
Rs.6100/- 7.5 kW to 11.0 kW,
Rs.6500/- 11.0 kW to 15.0 kW,
Rs.8900/- 15.0 kW to 20.0 kW,
Rs.10000/- 20.0 kW to 25.0 kW,
Rs.13600/- 25.0 kW to 30.0 kW
Rs.15100/- 30.0 kW to 37.0 kW. |
| Cl. 8(Earthing) |
- |
0 |
|
Rs.4400/- 3.7 kW,
Rs.4950/- 3.7 kW to 7.5 kW,
Rs.6100/- 7.5 kW to 11.0 kW,
Rs.6500/- 11.0 kW to 15.0 kW,
Rs.8900/- 15.0 kW to 20.0 kW,
Rs.10000/- 20.0 kW to 25.0 kW,
Rs.13600/- 25.0 kW to 30.0 kW
Rs.15100/- 30.0 kW to 37.0 kW. |
| Cl. 6(Method of cooling) |
- |
0 |
|
Rs.4400/- 3.7 kW,
Rs.4950/- 3.7 kW to 7.5 kW,
Rs.6100/- 7.5 kW to 11.0 kW,
Rs.6500/- 11.0 kW to 15.0 kW,
Rs.8900/- 15.0 kW to 20.0 kW,
Rs.10000/- 20.0 kW to 25.0 kW,
Rs.13600/- 25.0 kW to 30.0 kW
Rs.15100/- 30.0 kW to 37.0 kW. |
| Cl. 9(Terminal marking) |
- |
0 |
|
Rs.4400/- 3.7 kW,
Rs.4950/- 3.7 kW to 7.5 kW,
Rs.6100/- 7.5 kW to 11.0 kW,
Rs.6500/- 11.0 kW to 15.0 kW,
Rs.8900/- 15.0 kW to 20.0 kW,
Rs.10000/- 20.0 kW to 25.0 kW,
Rs.13600/- 25.0 kW to 30.0 kW
Rs.15100/- 30.0 kW to 37.0 kW. |
| Cl. 16.2.4(Temperature rise test ) |
- |
0 |
|
Rs.4400/- 3.7 kW,
Rs.4950/- 3.7 kW to 7.5 kW,
Rs.6100/- 7.5 kW to 11.0 kW,
Rs.6500/- 11.0 kW to 15.0 kW,
Rs.8900/- 15.0 kW to 20.0 kW,
Rs.10000/- 20.0 kW to 25.0 kW,
Rs.13600/- 25.0 kW to 30.0 kW
Rs.15100/- 30.0 kW to 37.0 kW. |
| Cl. 16.2.3(Full load test) |
- |
0 |
|
Rs.4400/- 3.7 kW,
Rs.4950/- 3.7 kW to 7.5 kW,
Rs.6100/- 7.5 kW to 11.0 kW,
Rs.6500/- 11.0 kW to 15.0 kW,
Rs.8900/- 15.0 kW to 20.0 kW,
Rs.10000/- 20.0 kW to 25.0 kW,
Rs.13600/- 25.0 kW to 30.0 kW
Rs.15100/- 30.0 kW to 37.0 kW. |
| Cl. 12.2(Pull up test) |
- |
0 |
|
Rs.4400/- 3.7 kW,
Rs.4950/- 3.7 kW to 7.5 kW,
Rs.6100/- 7.5 kW to 11.0 kW,
Rs.6500/- 11.0 kW to 15.0 kW,
Rs.8900/- 15.0 kW to 20.0 kW,
Rs.10000/- 20.0 kW to 25.0 kW,
Rs.13600/- 25.0 kW to 30.0 kW
Rs.15100/- 30.0 kW to 37.0 kW. |
| Cl. 16.1.4 & 16.2.2(Locked rotor readings) |
- |
0 |
|
Rs.4400/- 3.7 kW,
Rs.4950/- 3.7 kW to 7.5 kW,
Rs.6100/- 7.5 kW to 11.0 kW,
Rs.6500/- 11.0 kW to 15.0 kW,
Rs.8900/- 15.0 kW to 20.0 kW,
Rs.10000/- 20.0 kW to 25.0 kW,
Rs.13600/- 25.0 kW to 30.0 kW
Rs.15100/- 30.0 kW to 37.0 kW. |
| Cl. 16.1.5(Reduced voltage running test) |
- |
0 |
|
Rs.4400/- 3.7 kW,
Rs.4950/- 3.7 kW to 7.5 kW,
Rs.6100/- 7.5 kW to 11.0 kW,
Rs.6500/- 11.0 kW to 15.0 kW,
Rs.8900/- 15.0 kW to 20.0 kW,
Rs.10000/- 20.0 kW to 25.0 kW,
Rs.13600/- 25.0 kW to 30.0 kW
Rs.15100/- 30.0 kW to 37.0 kW. |
| Cl. 16.1.3(No load at rated voltage) |
- |
0 |
|
Rs.4400/- 3.7 kW,
Rs.4950/- 3.7 kW to 7.5 kW,
Rs.6100/- 7.5 kW to 11.0 kW,
Rs.6500/- 11.0 kW to 15.0 kW,
Rs.8900/- 15.0 kW to 20.0 kW,
Rs.10000/- 20.0 kW to 25.0 kW,
Rs.13600/- 25.0 kW to 30.0 kW
Rs.15100/- 30.0 kW to 37.0 kW. |
| Cl. 16.1.2(Measurment of stator resistance) |
- |
0 |
|
Rs.4400/- 3.7 kW,
Rs.4950/- 3.7 kW to 7.5 kW,
Rs.6100/- 7.5 kW to 11.0 kW,
Rs.6500/- 11.0 kW to 15.0 kW,
Rs.8900/- 15.0 kW to 20.0 kW,
Rs.10000/- 20.0 kW to 25.0 kW,
Rs.13600/- 25.0 kW to 30.0 kW
Rs.15100/- 30.0 kW to 37.0 kW. |
| Cl. 18.3(BIS Certification Marking) |
- |
0 |
|
Rs.4400/- 3.7 kW,
Rs.4950/- 3.7 kW to 7.5 kW,
Rs.6100/- 7.5 kW to 11.0 kW,
Rs.6500/- 11.0 kW to 15.0 kW,
Rs.8900/- 15.0 kW to 20.0 kW,
Rs.10000/- 20.0 kW to 25.0 kW,
Rs.13600/- 25.0 kW to 30.0 kW
Rs.15100/- 30.0 kW to 37.0 kW. |
| Cl. 15.2(rating) |
- |
0 |
|
Rs.4400/- 3.7 kW,
Rs.4950/- 3.7 kW to 7.5 kW,
Rs.6100/- 7.5 kW to 11.0 kW,
Rs.6500/- 11.0 kW to 15.0 kW,
Rs.8900/- 15.0 kW to 20.0 kW,
Rs.10000/- 20.0 kW to 25.0 kW,
Rs.13600/- 25.0 kW to 30.0 kW
Rs.15100/- 30.0 kW to 37.0 kW. |
| Cl. 18.1(Marking and labelling) |
- |
0 |
|
Rs.4400/- 3.7 kW,
Rs.4950/- 3.7 kW to 7.5 kW,
Rs.6100/- 7.5 kW to 11.0 kW,
Rs.6500/- 11.0 kW to 15.0 kW,
Rs.8900/- 15.0 kW to 20.0 kW,
Rs.10000/- 20.0 kW to 25.0 kW,
Rs.13600/- 25.0 kW to 30.0 kW
Rs.15100/- 30.0 kW to 37.0 kW. |
| Cl-12.1(Momentary Excess Torque) |
- |
0 |
|
Rs.4400/- 3.7 kW,
Rs.4950/- 3.7 kW to 7.5 kW,
Rs.6100/- 7.5 kW to 11.0 kW,
Rs.6500/- 11.0 kW to 15.0 kW,
Rs.8900/- 15.0 kW to 20.0 kW,
Rs.10000/- 20.0 kW to 25.0 kW,
Rs.13600/- 25.0 kW to 30.0 kW
Rs.15100/- 30.0 kW to 37.0 kW. |
| Cl-12.2(Pull-up-Torque) |
- |
0 |
|
Rs.4400/- 3.7 kW,
Rs.4950/- 3.7 kW to 7.5 kW,
Rs.6100/- 7.5 kW to 11.0 kW,
Rs.6500/- 11.0 kW to 15.0 kW,
Rs.8900/- 15.0 kW to 20.0 kW,
Rs.10000/- 20.0 kW to 25.0 kW,
Rs.13600/- 25.0 kW to 30.0 kW
Rs.15100/- 30.0 kW to 37.0 kW. |
| Cl-12.3(Sustained Overloads) |
- |
0 |
|
Rs.4400/- 3.7 kW,
Rs.4950/- 3.7 kW to 7.5 kW,
Rs.6100/- 7.5 kW to 11.0 kW,
Rs.6500/- 11.0 kW to 15.0 kW,
Rs.8900/- 15.0 kW to 20.0 kW,
Rs.10000/- 20.0 kW to 25.0 kW,
Rs.13600/- 25.0 kW to 30.0 kW
Rs.15100/- 30.0 kW to 37.0 kW. |
| Cl-13(Temperature Rise) |
- |
0 |
|
Rs.4400/- 3.7 kW,
Rs.4950/- 3.7 kW to 7.5 kW,
Rs.6100/- 7.5 kW to 11.0 kW,
Rs.6500/- 11.0 kW to 15.0 kW,
Rs.8900/- 15.0 kW to 20.0 kW,
Rs.10000/- 20.0 kW to 25.0 kW,
Rs.13600/- 25.0 kW to 30.0 kW
Rs.15100/- 30.0 kW to 37.0 kW. |
| Cl-14(Performance Values) |
- |
0 |
|
Rs.4400/- 3.7 kW,
Rs.4950/- 3.7 kW to 7.5 kW,
Rs.6100/- 7.5 kW to 11.0 kW,
Rs.6500/- 11.0 kW to 15.0 kW,
Rs.8900/- 15.0 kW to 20.0 kW,
Rs.10000/- 20.0 kW to 25.0 kW,
Rs.13600/- 25.0 kW to 30.0 kW
Rs.15100/- 30.0 kW to 37.0 kW. |
| Cl-15(Efficiency) |
- |
0 |
|
Rs.4400/- 3.7 kW,
Rs.4950/- 3.7 kW to 7.5 kW,
Rs.6100/- 7.5 kW to 11.0 kW,
Rs.6500/- 11.0 kW to 15.0 kW,
Rs.8900/- 15.0 kW to 20.0 kW,
Rs.10000/- 20.0 kW to 25.0 kW,
Rs.13600/- 25.0 kW to 30.0 kW
Rs.15100/- 30.0 kW to 37.0 kW. |
| Cl. 18.2(Marking and labelling) |
- |
0 |
|
Rs.4400/- 3.7 kW,
Rs.4950/- 3.7 kW to 7.5 kW,
Rs.6100/- 7.5 kW to 11.0 kW,
Rs.6500/- 11.0 kW to 15.0 kW,
Rs.8900/- 15.0 kW to 20.0 kW,
Rs.10000/- 20.0 kW to 25.0 kW,
Rs.13600/- 25.0 kW to 30.0 kW
Rs.15100/- 30.0 kW to 37.0 kW. |
|
28 Oct, 2028 |
- Complete For:
2 Pole motors up to 140 KW
4 Pole motors up to 60 KW
6 Pole motors up to 40 KW
8 Pole motors up to 22 KW |