6.2.1
Annex B(Chloride Content of Resin) |
- |
2000 |
|
- |
6.3.1
Annex B(Chloride content) |
- |
2000 |
|
- |
6.3.2
Annex C(Verification of the Malfunction Temperature, Tmal:
) |
- |
25000 |
|
- |
6.3.2
IS 13360 (Part 3/See 1)(Density) |
- |
500 |
|
- |
7.1
IS 12235 (Part 1)
Table 2(Dimension of Pipes:
Mean outside Diameter) |
- |
500 |
|
- |
7.1,7.1.1
IS 12235 (Part 1)
Table 2(Outside Diameter at any point) |
- |
500 |
|
- |
7.1.2
IS 12235 (Part 1)
Table 2(Wall Thickness ) |
- |
500 |
|
- |
7.1.3 (Effective length) |
- |
500 |
|
- |
8(Pipe Ends) |
- |
500 |
|
- |
9.1(Visual Appearance) |
- |
500 |
|
- |
9.2
IS 12235 (Part 3)(Opacity) |
- |
2000 |
|
- |
Cl. 9.3,IS 4985 Cl. 10.3(Lead (first extraction)) |
- |
5000 |
|
- |
Cl. 9.3,IS 4985 Cl. 10.3(Lead (third extraction)) |
- |
5000 |
|
- |
Cl. 9.3,IS 4985 Cl. 10.3(Dialkyl tin C4 and higher homologues measured as tin (third extraction)) |
- |
5000 |
|
- |
Cl. 9.3,IS 4985 Cl. 10.3(Cadmium (for all three extracts) ) |
- |
5000 |
|
- |
Cl. 9.3,IS 4985 Cl. 10.3(Mercury (for all three extracts) ) |
- |
5000 |
|
- |
Cl. 9.3,IS 4985 Cl. 10.3(Other toxic substances such as 'di-n-octyl-tin- s-s bis iso-octyl mercapto acetate' and 'butyl stearate' (third extraction) ) |
- |
5000 |
|
- |
Cl. 9.3,IS 4985 Cl. 10.3(Other toxic substances including di-n-octyl-tin- s-s bis iso-octyl mercapto acetate' and 'butyl stearate') |
- |
5000 |
|
- |
9.4
IS 12235(Part 5/Sec 1 and Sec 2)(Reversion Test :
When tested by the method prescribed in IS 12235(Part 5/Sec 1 and Sec 2), a length of pipe 200 + 20 mm long shall not alter in length by more than 5 percent.) |
- |
1500 |
|
- |
9.5
IS 12235(Part 2)(Vicat Softening Temperature:
When tested by the method prescribed in IS 12235(Part 2), the Vicat softening temperature of the specimen
shall not be less than 110°C.) |
- |
1500 |
|
- |
9.6
IS 12235(Part 14)(Density) |
- |
500 |
|
- |
10.1
Table 3
IS 12235
(Part 8/Sec 1)(Hydrostatic Characteristics) |
- |
5000 |
|
- |
10.2
Table 3
IS 12235
(Part 8/Sec 1)(Thermal Stability by Hydrostatic Pressure Testing) |
- |
25000 |
|
- |
10.3
IS 4985
Table 4(Resistance to External Blow at O°C:
When tested by the method prescribed in IS 4985, with classified striker mass and drop height as given in Table 4, the pipe shall have a true impact rate of not more than 10 percent.) |
- |
1500 |
|
- |
10.4
IS 12235(Part 19)(Flattening Test) |
- |
1500 |
|
- |
10.5
IS 12235(Part 13)(Tensile Strength :
When tested by the method prescribed in IS 12235(Part 13), the tensile strength at yield shall not be less than 50 MPaat 27±2°C.
) |
- |
2000 |
|
- |
6.3(K value Test) |
- |
5000 |
|
- |
7.1.2(Wall Thickness (Maximum)) |
- |
500 |
|
- |