1 |
IS 2997 (1964) |
Specification for air circulator type electric fans and regulators |
- |
-
|
45000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
4.1(Preffered voltages) |
- |
250 |
|
-- |
5.1(standard frequency) |
- |
250 |
|
-- |
6.1(Number of Phases) |
- |
250 |
|
-- |
7.1(Induction motors) |
- |
250 |
|
-- |
8.1(Stampings ) |
- |
500 |
|
-- |
8.2(Enclosures) |
- |
100 |
|
-- |
8.3(Blades) |
- |
100 |
|
-- |
8.4(Guard) |
- |
100 |
|
-- |
8.5(Heat Resistance) |
- |
100 |
|
-- |
8.6(Moisture Resistance -) |
- |
100 |
|
-- |
8.7(Bearings -) |
- |
100 |
|
-- |
8.8(Commutator segments) |
- |
100 |
|
-- |
8.9(Carbon brushes) |
- |
100 |
|
-- |
8.1(Brush Holder Springs -) |
- |
100 |
|
-- |
8.11(Supply Cord-) |
- |
100 |
|
-- |
8.12(Cord-Grip) |
- |
100 |
|
-- |
8.13(Protective Measures ) |
- |
100 |
|
-- |
8.14(Protection Against Direct Contact -) |
- |
100 |
|
-- |
8.15(Method of Mounting -) |
- |
100 |
|
-- |
8.16(Capacitors -) |
- |
100 |
|
-- |
8.17(Stability -) |
- |
100 |
|
-- |
8.18(Finish -) |
- |
100 |
|
-- |
8.19(Insulating Material -) |
- |
100 |
|
-- |
9(Height of the Fan) |
- |
500 |
|
-- |
10(SPEED REGULATORS ) |
- |
2000 |
|
-- |
11(Starting) |
- |
500 |
|
-- |
12(Interchangeability) |
- |
500 |
|
-- |
13(SILENT OPERATION) |
- |
1000 |
|
-- |
14(COMMUTATION) |
- |
500 |
|
-- |
15(OSCILLATING MECHANISM) |
- |
1000 |
|
-- |
16(STANDARD OF PERFORMANCE) |
- |
500 |
|
-- |
17(TOLERANCES ON RATINGS) |
- |
500 |
|
-- |
18(Marking) |
- |
1000 |
|
-- |
19 a)(Type test) |
- |
250 |
|
-- |
19 b)(Acceptance test) |
- |
250 |
|
-- |
19 c)(Routine test) |
- |
200 |
|
-- |
19.2(Air Delivery Test) |
- |
12000 |
|
-- |
19.3(Temperature-Rise of Fan Motor and Regulator) |
- |
4000 |
|
-- |
19.4(Moisture-Proofness Test) |
- |
3000 |
|
-- |
19.5(Cord-Grip Test) |
- |
1000 |
|
-- |
19.6(Mechanical Endurance Test for Regulator) |
- |
2000 |
|
-- |
19.7(Power Factor Test) |
- |
1000 |
|
-- |
19.8(ac Leakage Test) |
- |
3000 |
|
-- |
19.9(High Voltage Test) |
- |
2000 |
|
-- |
19.1(Insulation Resistance Test) |
- |
1000 |
|
-- |
19.11(Earthing Continuity test) |
- |
1000 |
|
-- |
19.12(Electrical Input Test) |
- |
1000 |
|
-- |
19.13(Measurement of Fan Speed) |
- |
1000 |
|
-- |
19.14(Flash Test -) |
- |
1000 |
|
-- |
|
Complete
|
|
25 Oct, 2027 |
- - |
2 |
IS 2312 (1967) |
Specification for propeller type AC ventilating fans (First Revision) |
- |
-
|
45000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
3.1(Sizes ) |
- |
500 |
|
-- |
4.1(Rated Voltage) |
- |
500 |
|
-- |
5.1(Rated frequency) |
- |
500 |
|
-- |
6.1(Design and General Construction) |
- |
250 |
|
-- |
6.3(Design and General Construction) |
- |
250 |
|
-- |
6.4(Design and General Construction) |
- |
250 |
|
-- |
6.5(Design and General Construction) |
- |
250 |
|
-- |
6.6(Design and General Construction) |
- |
250 |
|
-- |
6.7(Design and General Construction) |
- |
250 |
|
-- |
6.9(Design and General Construction) |
- |
250 |
|
-- |
6.1(Design and General Construction) |
- |
250 |
|
-- |
6.11(Design and General Construction) |
- |
250 |
|
-- |
6.12(Design and General Construction) |
- |
250 |
|
-- |
7.1(Design and General Construction) |
- |
500 |
|
-- |
8.1(Design and General Construction) |
- |
500 |
|
-- |
9(Design and General Construction) |
- |
2000 |
|
-- |
10.1(Starting ) |
- |
1000 |
|
-- |
11.1(Interchangeability) |
- |
500 |
|
-- |
12(Silent Operation) |
- |
1000 |
|
-- |
13.1(Marking) |
- |
200 |
|
-- |
13.1 (a)(Marking) |
- |
200 |
|
-- |
13.1 (b)(Marking) |
- |
200 |
|
-- |
13.1 (c)(Marking) |
- |
200 |
|
-- |
13.1 (d)(Marking) |
- |
200 |
|
-- |
13.1 (e)(Marking) |
- |
200 |
|
-- |
13.1 (f)(Marking) |
- |
200 |
|
-- |
13.1 (g)(Marking) |
- |
200 |
|
-- |
13.1 (h)(Marking) |
- |
200 |
|
-- |
13.1 (j)(Marking) |
- |
200 |
|
-- |
13.2(Marking) |
- |
200 |
|
-- |
13.4(Marking) |
- |
200 |
|
-- |
14.2 & 15.1(Air Delivery) |
- |
12000 |
|
-- |
14.3(Temperature-Rise) |
- |
1000 |
|
-- |
14.3(Temperature-Rise) |
- |
1000 |
|
-- |
14.3(Temperature-Rise) |
- |
1000 |
|
-- |
14.3(Temperature-Rise) |
- |
1000 |
|
-- |
14.3(Temperature-Rise) |
- |
1000 |
|
-- |
14.3(Temperature-Rise) |
- |
1000 |
|
-- |
14.3(Temperature-Rise) |
- |
1000 |
|
-- |
14.4(Moistureproofness (for regulators only)) |
- |
2000 |
|
-- |
14.5(Mechanical Endurance (for regulators only)) |
- |
2500 |
|
-- |
14.1 & 14.6(Power factor) |
- |
500 |
|
-- |
14.7(ac leakage) |
- |
2000 |
|
-- |
14.8(High voltage test) |
- |
2000 |
|
-- |
14.9(Insulation-Resistance) |
- |
1000 |
|
-- |
14.1(Earthing continuity) |
- |
1000 |
|
-- |
14.11 & 15.1(Electrical Input) |
- |
1000 |
|
-- |
14.12 & 16(Fan Speed) |
- |
1000 |
|
-- |
14.13(Flash Test) |
- |
1000 |
|
-- |
Cl-16(Tolerances on ratings) |
- |
100 |
|
-- |
|
Complete
|
|
25 Oct, 2027 |
- - |
3 |
IS 555 (1979) |
Specification for electric table type fans and regulators (Third Revision) |
- |
-
|
45000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
3.0(Size, Speed and Types) |
- |
1000 |
|
-- |
4.0(Rated Voltages) |
- |
500 |
|
-- |
5.0(Rated Frequency) |
- |
500 |
|
-- |
6.0(Design and General Construction) |
- |
1000 |
|
-- |
7.1(Protection Against Electric Shock) |
- |
1000 |
|
-- |
7.2(Electrical Insulation Under Normal Operating Conditions) |
- |
1000 |
|
-- |
7.3(Temperature-rise) |
- |
1000 |
|
-- |
7.5(Creepage Distances and Clearances) |
- |
1000 |
|
-- |
7.6(Finish) |
- |
500 |
|
-- |
7.8(Speed Regulators) |
- |
2000 |
|
-- |
7.9(Interchangeability) |
- |
500 |
|
-- |
7.11(Oscillating Mechanism) |
- |
1000 |
|
-- |
8.1, 8.2(Air delivery and service value) |
- |
500 |
|
-- |
9.0(Marking) |
- |
1500 |
|
-- |
10.3(Air Delivery Test) |
- |
12000 |
|
-- |
10.4(Temperature-Rise Test) |
- |
3000 |
|
-- |
10.5(Leakage Current) |
- |
2000 |
|
-- |
10.6(High Voltage Test) |
- |
2000 |
|
-- |
10.7(Insulation-Resistance Test (Shall follow Moisture Resistance Test Cl.10.12)) |
- |
1000 |
|
-- |
10.8(Construction) |
- |
1000 |
|
-- |
10.9(Fan Speed and Input) |
- |
2000 |
|
-- |
10.1(Earthing Connection) |
- |
1000 |
|
-- |
10.11(Protection against Electric Shock) |
- |
1000 |
|
-- |
10.12(Moisture Resistance Test) |
- |
3000 |
|
-- |
10.13, 7.4(Mechanical Endurance Test (for Regulators Only)) |
- |
2000 |
|
-- |
10.14(Cord Grip Test) |
- |
1000 |
|
-- |
10.16(Creepage Distances and Clearances) |
- |
1000 |
|
-- |
|
Complete
|
|
25 Oct, 2027 |
- - |
4 |
IS 1169 (1967) |
Specification for electric pedestal type fans and regulators (First Revision) |
- |
-
|
45000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
3(Sizes, Speed & Types) |
- |
500 |
|
-- |
4(Rated Voltage) |
- |
500 |
|
-- |
5(Rated Frequency) |
- |
500 |
|
-- |
10(Speed Regulators) |
- |
2000 |
|
-- |
11(Starting) |
- |
1000 |
|
-- |
6(Design and General
Construction) |
- |
2000 |
|
-- |
7(Finish) |
- |
500 |
|
-- |
8(Height of the Fan) |
- |
500 |
|
-- |
12(Interchangeability) |
- |
1000 |
|
-- |
13(Silent Operation) |
- |
1000 |
|
-- |
14(Oscillating Mechanism) |
- |
1000 |
|
-- |
15(Marking) |
- |
1000 |
|
-- |
16.2(Air Delivery Test) |
- |
12000 |
|
-- |
16.3(Temperature-rise) |
- |
5000 |
|
-- |
16.4(Moisture Proofness Test (for
Regulators only)) |
- |
3000 |
|
-- |
16.5(Cord grip test) |
- |
2000 |
|
-- |
16.6(Mechanical Endurance Test (for
Regulators only)) |
- |
2000 |
|
-- |
16.7(Power Factor) |
- |
1000 |
|
-- |
16.8(AC Leakage Test) |
- |
2000 |
|
-- |
16.9(High Voltage) |
- |
2000 |
|
-- |
16.1(Earthing Continuity Test) |
- |
1000 |
|
-- |
16.11(Electrical Input Test) |
- |
1000 |
|
-- |
16.12(Measurement of Fan Speed) |
- |
1000 |
|
-- |
16.14(Insulation-resistance ) |
- |
1000 |
|
-- |
17(Performance Reqirement) |
- |
250 |
|
-- |
18( Tolerances on rating) |
- |
250 |
|
-- |
|
Complete
|
|
25 Oct, 2027 |
- - |
5 |
IS 11188 : Part 1 (2021) |
Vault Strong Room doors Part 1 specification |
- |
-
|
350000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
4(Type) |
- |
5000 |
|
- |
5 Table 1(bolts, Min) |
- |
15000 |
|
- |
5 Table 1(xix) Depth of engagement of shooting) |
- |
5000 |
|
- |
5 Table 1(cross sectional area, Min,sq mm) |
- |
5000 |
|
- |
5 Table 1(xviii) Diameter of shooting bolts, Min) |
- |
5000 |
|
- |
5 Table 1(xvi) Number of shooting bolts at top,Min) |
- |
5000 |
|
- |
5 Table 1(xv) Number of shooting bolts on opposite side,Min) |
- |
5000 |
|
- |
5 Table 1(xiv) Number of shooting bolts on hinge side, Min) |
- |
5000 |
|
- |
5 Table 1(xiii) Number of locks) |
- |
5000 |
|
- |
5 Table 1(xii) Wall thickness (recommendation)) |
- |
5000 |
|
- |
5 Table 1(xi) Thickness of drill and oxyacetylene
torch resisting layer (excluding mild steel plates),Min) |
- |
5000 |
|
- |
5 Table 1(ix) Thickness of doors slab, thickness over rebate) |
- |
5000 |
|
- |
5 Table 1(viii) Pitch of grill gate rods) |
- |
5000 |
|
- |
5 Table 1(vii) Diameter of grill gate rods, Min) |
- |
5000 |
|
- |
5 Table 1(vi) Thickens of grill gate angles or
section made out of M.S. plates, Min) |
- |
5000 |
|
- |
5 Table 1(v) Dimension of the rebate coming under shear) |
- |
5000 |
|
- |
5 Table 1(iv (b) Thickness of door frame, if
fabricated from single plate to form
channel/multi-bend section, Min) |
- |
5000 |
|
- |
5 Table 1(ii (a) Height H, Min b) Width W, Min
iv(a) Thickness of door frame angle,
channel or section made out of M.S.
plates, if built up to form a channel,Min) |
- |
15000 |
|
- |
5 Table 1(iii) Inside dimension or clear opening when
door shutters are swung open at 180 degree) |
- |
15000 |
|
- |
5 Table 1(ii (b) Width W) |
- |
10000 |
|
- |
5 Table 1(ii (a) Height, H) |
- |
5000 |
|
- |
5 Table 1(ii) Overall dimension of vault door) |
- |
5000 |
|
- |
5 Table 1(i) Door Type) |
- |
5000 |
|
- |
5(Table-1)(Type of Door) |
- |
3000 |
|
- |
6(Materail) |
- |
3000 |
|
- |
7(Classification) |
- |
5000 |
|
- |
8 & 8.1.1(Ventilating Grill Gate (Inside)) |
- |
5000 |
|
- |
8.1.1.1(Locking device (unpickable dual control lock)) |
- |
5000 |
|
- |
8.1.2(Main Door- Outer & inner plate thickness) |
- |
5000 |
|
- |
8.1.2.1(Door(Finish &Gap of frame/edge with any place)) |
- |
5000 |
|
- |
8.2(Door frame (No.of barckets & Size for gripping)) |
- |
5000 |
|
- |
8.2.1(Rebate of the door frame) |
- |
5000 |
|
- |
8.2.2(Compression mechanism) |
- |
5000 |
|
- |
8.2.3(Crane hinge mechanism) |
- |
5000 |
|
- |
8.3(Lock case) |
- |
5000 |
|
- |
8.3.2(Bolt work) |
- |
5000 |
|
- |
8.3.2.2(Construction (of bolt work)) |
- |
5000 |
|
- |
8.3.2.3(Bearing piller) |
- |
5000 |
|
- |
8.4.1(Shooting bolt control (By lock)) |
- |
5000 |
|
- |
8.4.2(Test of key-Lock) |
- |
25000 |
|
- |
8.4.3(Lock fixing bolts) |
- |
5000 |
|
- |
8.4.4(Time lock) |
- |
5000 |
|
- |
8.4.5(Automatic Relocking devise) |
- |
5000 |
|
- |
9 &9.1(Hinges) |
- |
5000 |
|
- |
9.1.1(Adjusting bolt) |
- |
5000 |
|
- |
9.2(Handles) |
- |
5000 |
|
- |
9.3(Foot bringe) |
- |
5000 |
|
- |
9.4(Vault lighting control) |
- |
5000 |
|
- |
10 &10.1(Dents,Burrs & Edges) |
- |
5000 |
|
- |
10.2(Colour coating thickness (Surafce paint)) |
- |
5000 |
|
- |
10.3(Cross Hatch test) |
- |
5000 |
|
- |
10.4(Door (Stainless cladding)) |
- |
5000 |
|
- |
11.1 &11.2(Test criteria for confomity -Burglaty attack) |
- |
170000 |
|
- |
11.1 &11.2(Test criteria for confomity -Fire resistancey) |
- |
220000 |
|
- |
12(Marking of door) |
- |
5000 |
|
- |
12.2(Marking on keys) |
- |
5000 |
|
- |
11.1 (1)(Burglary resistance IS 11188 (Part 2)) |
- |
170000 |
|
- |
11.1 (3)(Fire and stream hose IS 11188 (Part 3)) |
- |
120000 |
|
- |
11.1 (2)(Fire endurance IS 11188 (Part 3)) |
- |
130000 |
|
- |
10.4(Alternate to Cl 10.4) |
- |
5000 |
|
- |
10.3(Cross Hatch Test) |
- |
15000 |
|
- |
10(FINISH) |
- |
5000 |
|
- |
9.4(Vault Lighting Control) |
- |
5000 |
|
- |
9.3(Foot Bridge) |
- |
5000 |
|
- |
9.2(Handles) |
- |
5000 |
|
- |
9.1.1(Adjusting Bolt) |
- |
5000 |
|
- |
9.1(Hinges) |
- |
5000 |
|
- |
9(DOOR FITTINGS) |
- |
5000 |
|
- |
8.4.5(Automatic Relocking Device) |
- |
5000 |
|
- |
8.4.4(Time Lock) |
- |
5000 |
|
- |
8.4(Lock) |
- |
5000 |
|
- |
8.3.2.2(Construction) |
- |
5000 |
|
- |
8.3.2.1(The number of bolts and their minimum dimension) |
- |
5000 |
|
- |
8.3.2(Bolt Work) |
- |
5000 |
|
- |
8.3.1(Lock Case) |
- |
5000 |
|
- |
8.3(Locking Mechanism) |
- |
5000 |
|
- |
8.2.3(Crane Hinge Mechanism) |
- |
5000 |
|
- |
8.2.2(Compression Mechanism) |
- |
5000 |
|
- |
8.2.1(Rebate of the Door Frame) |
- |
5000 |
|
- |
8.2(Doors Frame) |
- |
5000 |
|
- |
8.1.2(Main Door (Outside)) |
- |
5000 |
|
- |
8.1.1(Ventilating Grill Gate (Inside)) |
- |
5000 |
|
- |
8.1 Fig. 1(Doors) |
- |
5000 |
|
- |
8(CONSTRUCTION AND GENERALREQUIREMENTS) |
- |
5000 |
|
- |
5(Table-1)(Overall dimesion of door) |
- |
5000 |
|
- |
5(Table-1)(Inside dimension or clear opening of door) |
- |
5000 |
|
- |
5(Table-1)(Thickness of door frame angle-made of Plate,if bulit up to form a channel) |
- |
5000 |
|
- |
5(Table-1)(Thickness of door frame ,if fabricated or multibend) |
- |
5000 |
|
- |
5(Table-1)(Dimension of the rebate coming under share) |
- |
5000 |
|
- |
5(Table-1)(Thickness of grill gate angle/section) |
- |
5500 |
|
- |
5(Table-1)(Diameter of grill gate rod) |
- |
5000 |
|
- |
5(Table-1)(Pitch of grill gate rod) |
- |
5000 |
|
- |
5(Table-1)(Thickness of door slab,thickness over rebate) |
- |
5000 |
|
- |
5(Table-1)(Thickness of the door over lock) |
- |
5000 |
|
- |
5(Table-1)(Thickness of drill & oxyacetylene torch resis. layer(exclue MS plate) |
- |
5000 |
|
- |
5(Table-1)(Wall thickness) |
- |
5000 |
|
- |
5(Table-1)(Number of locks) |
- |
5000 |
|
- |
5(Table-1)(Number of shooting bolys on hinge side) |
- |
5000 |
|
- |
5(Table-1)(Number of shooting bolts on opposite) |
- |
5000 |
|
- |
5(Table-1)(Number of shooting bolts at top) |
- |
5000 |
|
- |
5(Table-1)(Number of shooting bolts at bottom) |
- |
5000 |
|
- |
5(Table-1)(Cross sectional area as per shooting bolt) |
- |
5000 |
|
- |
5(Table-1)(Depth engagement of shooting) |
- |
5000 |
|
- |
4(Type) |
- |
5000 |
|
- |
5(Table-1)(5(Table-1)) |
- |
5000 |
|
- |
5(Table-1)(Overall dimesion of door) |
- |
5000 |
|
- |
5(Table-1)(Inside dimension or clear opening of door) |
- |
5000 |
|
- |
5(Table-1)(Thickness of door frame angle-made of Plate,if bulit up to form a channel) |
- |
5000 |
|
- |
5(Table-1)(Thickness of door frame ,if fabricated or multibend) |
- |
5000 |
|
- |
5(Table-1)(Dimension of the rebate coming under share) |
- |
5000 |
|
- |
5(Table-1)(Thickness of grill gate angle/section) |
- |
5000 |
|
- |
5(Table-1)(Diameter of grill gate rod) |
- |
5000 |
|
- |
5(Table-1)(Pitch of grill gate rod) |
- |
5000 |
|
- |
5(Table-1)(Thickness of door slab,thickness over rebate) |
- |
5000 |
|
- |
5(Table-1)(Thickness of the door over lock) |
- |
5000 |
|
- |
5(Table-1)(Thickness of drill & oxyacetylene torch resis. layer(exclue MS plate) |
- |
5000 |
|
- |
5(Table-1)(Wall thickness) |
- |
5000 |
|
- |
5(Table-1)(Number of locks) |
- |
5000 |
|
- |
5(Table-1)(Number of shooting bolys on hinge side) |
- |
5000 |
|
- |
5(Table-1)(Number of shooting bolts at top) |
- |
5000 |
|
- |
5(Table-1)(Number of shooting bolts at bottom) |
- |
5000 |
|
- |
5(Table-1)(Cross sectional area as per shooting bolt) |
- |
6000 |
|
- |
5(Table-1)(Depth engagement of shooting) |
- |
5000 |
|
- |
6(Materail) |
- |
5000 |
|
- |
7(Classification) |
- |
5000 |
|
- |
8 & 8.1.1(Ventilating Grill Gate (Inside)) |
- |
5000 |
|
- |
8.1.1.1(Locking device (unpickable dual control lock)) |
- |
5000 |
|
- |
8.1.2(Main Door- Outer & inner plate thickness) |
- |
5000 |
|
- |
8.1.2.1(Door(Finish &Gap of frame/edge with any place)) |
- |
5000 |
|
- |
8.2(Door frame (No.of barckets & Size for gripping)) |
- |
5000 |
|
- |
8.2.1(Rebate of the door frame) |
- |
5000 |
|
- |
8.2.2(Compression mechanism) |
- |
5000 |
|
- |
8.2.3(Crane hinge mechanism) |
- |
5000 |
|
- |
8.3(Lock case) |
- |
5000 |
|
- |
8.3.2(Bolt work) |
- |
5000 |
|
- |
8.3.2.2(Construction (of bolt work)) |
- |
5000 |
|
- |
8.3.2.3(Bearing piller) |
- |
5000 |
|
- |
8.4.1(Shooting bolt control (By lock)) |
- |
5000 |
|
- |
8.4.2(Test of key-Lock) |
- |
25000 |
|
- |
8.4.3(Lock fixing bolts) |
- |
5000 |
|
- |
8.4.4(Time lock) |
- |
5000 |
|
- |
8.4.5(Automatic Relocking devise) |
- |
5000 |
|
- |
9 &9.1(Hinges) |
- |
5000 |
|
- |
9.1.1(Adjusting bolt) |
- |
5000 |
|
- |
9.3(Foot bringe) |
- |
5000 |
|
- |
9.4(Vault lighting control) |
- |
5000 |
|
- |
10 &10.1(Dents,Burrs & Edges) |
- |
5000 |
|
- |
10.2(Colour coating thickness (Surafce paint)) |
- |
5000 |
|
- |
10.3(Cross Hatch test) |
- |
25000 |
|
- |
10.4(Door (Stainless cladding)) |
- |
5000 |
|
- |
11.1 &11.2(Test criteria for confomity -Burglaty attack) |
- |
170000 |
|
- |
11.1 &11.2(Test criteria for confomity -Fire resistancey) |
- |
220000 |
|
- |
12(Marking of door) |
- |
5000 |
|
- |
12.2(Marking on keys) |
- |
5000 |
|
- |
|
Complete
|
|
25 Oct, 2027 |
- - |
6 |
IS 550 : Part 1 (2022) |
Safes: Part 1 specification Fifth Revision |
- |
-
|
380000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
4(Classification) |
- |
5000 |
|
- |
5.1(Dimensions) |
- |
5000 |
|
- |
5.2(Sizes) |
- |
5000 |
|
- |
6(Material declaration) |
- |
5000 |
|
- |
7(Desigantion-Delaration) |
- |
5000 |
|
- |
8.1(Body (Construction & workmanship)) |
- |
5000 |
|
- |
8.2(Door (Gap)) |
- |
5000 |
|
- |
8.4.1(Hinges) |
- |
5000 |
|
- |
8.4.2(Bolts) |
- |
5000 |
|
- |
8.5(Handle) |
- |
5000 |
|
- |
8.6.1(Lock (key type) Garde) |
- |
5000 |
|
- |
8.8(Cable hole size) |
- |
5000 |
|
- |
9(Internal fixture) |
- |
5000 |
|
- |
10(Painting) |
- |
5000 |
|
- |
10.1(Cross hatch test) |
- |
5000 |
|
- |
11.1(Marking of safe) |
- |
5000 |
|
- |
12(Burglary attack) |
- |
150000 |
|
- |
12(Fire Resistance) |
- |
150000 |
|
- |
|
Complete
|
|
25 Oct, 2027 |
- - |
7 |
IS 16333 : Part 3 (2022) |
Mobile phone handsets: Part 3 Indian language support for mobile phone handsets - Specific requirements(Second Revision) |
Indian language support for cell phones |
-
|
12000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
5.1(Inputting of text) |
- |
5000 |
|
-- |
6(Marking) |
- |
2000 |
|
-- |
5.2(Message Readability) |
- |
5000 |
|
-- |
|
Complete
|
|
25 Oct, 2027 |
- - |
8 |
IS 5244 (2020) |
Safe Deposit Locker Cabinets — Specification ( Fourth Revision ) |
- |
-
|
40000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Cl. 4.1( Types ) |
- |
1000 |
|
- |
Cl. 6 (Fig-5)(Cabinet Size (in mm)) |
- |
1000 |
|
- |
Table 1(Thickness Min. (in mm)) |
- |
1000 |
|
- |
Table 1(Finish) |
- |
1000 |
|
- |
Cl.6(Sizes (Minimum Inside Measurements of locker) Locker Size) |
- |
1000 |
|
- |
Cl. 7.1(Design and Manufacture) |
- |
1000 |
|
- |
Cl. 7.2(Design and Manufacture) |
- |
1000 |
|
- |
Cl. 7.3(Design and Manufacture) |
- |
1000 |
|
- |
Cl. 7.4(Design and Manufacture) |
- |
1000 |
|
- |
Cl. 7.5(Design and Manufacture) |
- |
1000 |
|
- |
Cl. 7.6(Design and Manufacture) |
- |
1000 |
|
- |
Cl. 8(Workmanship) |
- |
1000 |
|
- |
Cl. 8.2(Tolerance) |
- |
1000 |
|
- |
Cl. 9.1(Testing) |
- |
25000 |
|
- |
Cl. 9.2(Testing) |
- |
20000 |
|
- |
Cl. 9.3(Cross Hatch Test) |
- |
20000 |
|
- |
Cl. 10.1(Marking) |
- |
1500 |
|
- |
Cl. 10.2(Marking) |
- |
1500 |
|
- |
Cl. 10.3(Marking) |
- |
1500 |
|
- |
Cl. 10.4(Marking on Keys) |
- |
1500 |
|
- |
Cl. 11(Packing) |
- |
1500 |
|
- |
Cl. 4.1( Types ) |
- |
1000 |
|
- |
Cl. 6 (Fig-5)(Cabinet Size (in mm)) |
- |
1000 |
|
- |
Table 1(Thickness Min. (in mm)) |
- |
1000 |
|
- |
Table 1(Finish) |
- |
1000 |
|
- |
Cl.6(Sizes (Minimum Inside Measurements of locker) Locker Size) |
- |
1000 |
|
- |
Cl. 7.1(Design and Manufacture) |
- |
1000 |
|
- |
Cl. 7.2(Design and Manufacture) |
- |
1000 |
|
- |
Cl. 7.3(Design and Manufacture) |
- |
1000 |
|
- |
Cl. 7.4(Design and Manufacture) |
- |
1000 |
|
- |
Cl. 7.5(Design and Manufacture) |
- |
1000 |
|
- |
Cl. 7.6(Design and Manufacture) |
- |
1000 |
|
- |
Cl. 8(Workmanship) |
- |
1000 |
|
- |
Cl. 8.2(Tolerance) |
- |
1000 |
|
- |
Cl. 9.1(Testing) |
- |
25000 |
|
- |
Cl. 9.2(Testing) |
- |
25000 |
|
- |
Cl. 9.3(Cross Hatch Test) |
- |
20000 |
|
- |
Cl. 10.1(Marking) |
- |
1500 |
|
- |
Cl. 10.2(Marking) |
- |
1500 |
|
- |
Cl. 10.3(Marking) |
- |
1500 |
|
- |
Cl. 10.4(Marking on Keys) |
- |
1500 |
|
- |
Cl. 11(Packing) |
- |
1500 |
|
- |
Cl. 7.3(Design and Manufacture) |
- |
1000 |
|
- |
Cl.6(Sizes (Minimum Inside Measurements of locker) Locker Size) |
- |
1000 |
|
- |
Cl.6(Sizes (Minimum Inside Measurements of locker) Locker Size) |
- |
1000 |
|
- |
Cl. 7.1(Design and Manufacture) |
- |
1000 |
|
- |
Cl. 7.1(Design and Manufacture) |
- |
1000 |
|
- |
Cl. 7.1(Design and Manufacture) |
- |
1000 |
|
- |
Cl. 7.1(Design and Manufacture) |
- |
1000 |
|
- |
Table 1(Thickness Min. (in mm)) |
- |
1000 |
|
- |
Table 1(Thickness Min. (in mm)) |
- |
1000 |
|
- |
Table 1(Thickness Min. (in mm)) |
- |
1000 |
|
- |
Table 1(Thickness Min. (in mm)) |
- |
1000 |
|
- |
Table 1(Thickness Min. (in mm)) |
- |
1000 |
|
- |
Table 1(Thickness Min. (in mm)) |
- |
1000 |
|
- |
Table 1(Thickness Min. (in mm)) |
- |
1000 |
|
- |
Table 1(Finish) |
- |
1000 |
|
- |
Table 1(Thickness Min. (in mm)) |
- |
1000 |
|
- |
Table 1(Thickness Min. (in mm)) |
- |
1000 |
|
- |
Cl. 9.2(Testing) |
- |
20000 |
|
- |
Cl. 10.1(Marking) |
- |
1000 |
|
- |
Cl. 7.3(Design and Manufacture) |
- |
1000 |
|
- |
Cl.6(Sizes (Minimum Inside Measurements of locker) Locker Size) |
- |
1000 |
|
- |
Cl.6(Sizes (Minimum Inside Measurements of locker) Locker Size) |
- |
1000 |
|
- |
Cl. 7.1(Design and Manufacture) |
- |
1000 |
|
- |
Cl. 7.1(Design and Manufacture) |
- |
1000 |
|
- |
Cl. 7.1(Design and Manufacture) |
- |
1000 |
|
- |
Cl. 7.1(Design and Manufacture) |
- |
1000 |
|
- |
Table 1(Thickness Min. (in mm)) |
- |
1000 |
|
- |
Table 1(Thickness Min. (in mm)) |
- |
1000 |
|
- |
Table 1(Thickness Min. (in mm)) |
- |
1000 |
|
- |
Table 1(Thickness Min. (in mm)) |
- |
1000 |
|
- |
Table 1(Thickness Min. (in mm)) |
- |
1000 |
|
- |
Table 1(Thickness Min. (in mm)) |
- |
1000 |
|
- |
Table 1(Thickness Min. (in mm)) |
- |
1000 |
|
- |
Table 1(Finish) |
- |
1000 |
|
- |
Table 1(Thickness Min. (in mm)) |
- |
1000 |
|
- |
Table 1(Thickness Min. (in mm)) |
- |
1000 |
|
- |
|
Complete
|
|
25 Oct, 2027 |
- - |
9 |
IS 14203 (2017) |
Fire resisting record protection cabinets - Specification (Second Revision) |
- |
-
|
340000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
3(Nominal Sizes) |
- |
5000 |
|
- |
4(Types) |
- |
5000 |
|
- |
5(i) Steel components) |
- |
5000 |
|
- |
6(a) Heght) |
- |
5000 |
|
- |
6(b) Width) |
- |
5000 |
|
- |
6(c) Depth) |
- |
5000 |
|
- |
7(Designation) |
- |
5000 |
|
- |
8(General Constructions) |
- |
5000 |
|
- |
8.1(Cabinet construction) |
- |
5000 |
|
- |
8.1(i) Outer body and inner box shall be fabricated from mild steel or galvanised steel sheets of not less than 0.8 mm nominal thickness. The steel parts shall not have any burrs or dents. If required the outer body shall be suitably stiffened to avoid bulging) |
- |
5000 |
|
- |
8.1(The cabinet body of the fire resisting record protection cabinet shall be of double wall type with insulating material filled in-between. The insulating material should not produce toxic gases when the cabinet is exposed to fire situation The components shall be assembled by bolting,
welding, riveting or by any combination of these
methods) |
- |
5000 |
|
- |
8.2(Locking Mechanism: The locking mechanisms shall be of 4 way type. The diameter of shooting bolts shall be 15 mm to 20 mm.
There shall be minimum three shooting bolts (two
shooting bolts for size 1 000) on each side and minimum one vertical shooting bolt each on top and bottom. The shooting bolts shall slide smoothly in recess and engage in body to a minimum depth of 12 mm.) |
- |
5000 |
|
- |
8.3(Locks: The cabinet shall be supplied with a dual control key lock having minimum 6 levers with duplicate keys. The keys shall be made of stainless steel or any other non ferrous metal/alloy having non-corrosive properties.
Minimum two sets of the keys shall be supplied.
Alternatively three wheel combination locks in place of key lock or both may be provided, if required by the purchaser.
purchaser) |
- |
5000 |
|
- |
8.4(Handles: Handle shall be made from ferrous (powder coated/ plated), non-ferrous material or polymer) |
- |
5000 |
|
- |
9(Internal Fixtures:) |
- |
5000 |
|
- |
9.1(The cabinet shall be provided with minimum four shelves for nominal size 1 600, three shelves for nominal size 1 300 and two shelves for cabinets of nominal size 1 000. Shelf height shall be adjustable) |
- |
5000 |
|
- |
9.2(A cabinet may also be provided with drawer unit fitted with any suitable lock) |
- |
5000 |
|
- |
10(Painting) |
- |
5000 |
|
- |
10.1(i)The inside and outside surfaces of cabinet shall
be painted or powder coated. In case of paint an
appropriate primer and under coating shall be used in accordance with normal industrial practices) |
- |
5000 |
|
- |
10.1(ii)The minimum overall thickness of the coatings shall be 50 microns for powder coatings and 70 microns for liquid paints) |
- |
5000 |
|
- |
10.1.1(Cross hatch test shall be conducted to conform
the adhesion of coating in accordance with 10.2) |
- |
5000 |
|
- |
10.2(Cross Hatch Test: ) |
- |
5000 |
|
- |
10.2(a) Make 6 parallel cut marks using sharp metal
pointer and straight edge, through the painted/
coated surface, so as to make the base surface
visible through cut marks.) |
- |
5000 |
|
- |
10.2(b)Cut marks shall be minimum 20 mm long and
at 2 mm distance from each other.) |
- |
5000 |
|
- |
10.2(c)Make 6 similar cut marks in the direction
perpendicular to first set of cut marks, with
same length and spacing ) |
- |
5000 |
|
- |
10.2(d) These 12 cut marks together shall make a
pattern of 25 squares of 2 mm × 2 mm size,
totally separated from each other) |
- |
5000 |
|
- |
10.2(e) A good quality transparent adhesive tape not
less than 20 mm width, shall be stuck on the
pattern, parallel to any one set of cut marks) |
- |
5000 |
|
- |
10.2(f) To ensure continuous contact with paint/coat
film, rub the tape firmly and remove air
bubbles under the tape, if any) |
- |
5000 |
|
- |
10.2(g)Within 60 to 120 s after sticking the tape,
remove it by seizing free end of the tape and
rapidly pulling it off at an angle close to 180°.) |
- |
5000 |
|
- |
10.2(h) Painting/Coating quality is considered as
acceptable, if no part of any 2 mm × 2 mm
square of paint/coat comes off the surface due
to pulling the tape) |
- |
5000 |
|
- |
11.2(Fire endurance test: The fire resisting record protection cabinets shall be considered to be conforming to the requirements of this standard if they successfully complete the fire endurance test (see B-3.1) and fire and impact test (see B 3.2).) |
- |
170000 |
|
- |
11.2.1(The fire resisting record protection cabinets shall
be considered to be conforming to the requirements of this standard, if they pass the fire endurance test (see B-3.1) and fire and impact test (see B-3.2) if the
contents (see B-1.1, B-3.1.1, B-3.2.1) kept in the
cabinets during the test are found usable.) |
- |
10000 |
|
- |
12.1(Marking:A metal plate showing type of cabinet together with the manufacturer’s name and the year of manufacture shall be fixed on the inner face of the door) |
- |
5000 |
|
- |
12.2(Marking on Keys: The keys shall be marked with an identification number
which shall not be the same as the serial number of the
cabinet.) |
- |
5000 |
|
- |
3(Nominal Sizes) |
- |
- |
|
- |
4(Types) |
- |
- |
|
- |
5(i) Steel components) |
- |
- |
|
- |
6(a) Heght) |
- |
- |
|
- |
6(b) Width) |
- |
- |
|
- |
6(c) Depth) |
- |
- |
|
- |
7(Designation) |
- |
- |
|
- |
8(General Constructions) |
- |
- |
|
- |
8.1(Cabinet construction) |
- |
- |
|
- |
8.1(i) Outer body and inner box shall be fabricated from mild steel or galvanised steel sheets of not less than 0.8 mm nominal thickness. The steel parts shall not have any burrs or dents. If required the outer body shall be suitably stiffened to avoid bulging) |
- |
- |
|
- |
8.1(The cabinet body of the fire resisting record protection cabinet shall be of double wall type with insulating material filled in-between. The insulating material should not produce toxic gases when the cabinet is exposed to fire situation The components shall be assembled by bolting,
welding, riveting or by any combination of these
methods) |
- |
- |
|
- |
8.2(Locking Mechanism: The locking mechanisms shall be of 4 way type. The diameter of shooting bolts shall be 15 mm to 20 mm.
There shall be minimum three shooting bolts (two
shooting bolts for size 1 000) on each side and minimum one vertical shooting bolt each on top and bottom. The shooting bolts shall slide smoothly in recess and engage in body to a minimum depth of 12 mm.) |
- |
- |
|
- |
8.3(Locks: The cabinet shall be supplied with a dual control key lock having minimum 6 levers with duplicate keys. The keys shall be made of stainless steel or any other non ferrous metal/alloy having non-corrosive properties.
Minimum two sets of the keys shall be supplied.
Alternatively three wheel combination locks in place of key lock or both may be provided, if required by the purchaser.
purchaser) |
- |
- |
|
- |
8.4(Handles: Handle shall be made from ferrous (powder coated/ plated), non-ferrous material or polymer) |
- |
- |
|
- |
9(Internal Fixtures:) |
- |
- |
|
- |
9.1(The cabinet shall be provided with minimum four shelves for nominal size 1 600, three shelves for nominal size 1 300 and two shelves for cabinets of nominal size 1 000. Shelf height shall be adjustable) |
- |
- |
|
- |
9.2(A cabinet may also be provided with drawer unit fitted with any suitable lock) |
- |
- |
|
- |
10(Painting) |
- |
- |
|
- |
10.1(i)The inside and outside surfaces of cabinet shall
be painted or powder coated. In case of paint an
appropriate primer and under coating shall be used in accordance with normal industrial practices) |
- |
- |
|
- |
10.1(ii)The minimum overall thickness of the coatings shall be 50 microns for powder coatings and 70 microns for liquid paints) |
- |
- |
|
- |
10.1.1(Cross hatch test shall be conducted to conform
the adhesion of coating in accordance with 10.2) |
- |
- |
|
- |
10.2(Cross Hatch Test: ) |
- |
- |
|
- |
10.2(a) Make 6 parallel cut marks using sharp metal
pointer and straight edge, through the painted/
coated surface, so as to make the base surface
visible through cut marks.) |
- |
- |
|
- |
10.2(b)Cut marks shall be minimum 20 mm long and
at 2 mm distance from each other.) |
- |
- |
|
- |
10.2(c)Make 6 similar cut marks in the direction
perpendicular to first set of cut marks, with
same length and spacing ) |
- |
- |
|
- |
10.2(d) These 12 cut marks together shall make a
pattern of 25 squares of 2 mm × 2 mm size,
totally separated from each other) |
- |
- |
|
- |
10.2(e) A good quality transparent adhesive tape not
less than 20 mm width, shall be stuck on the
pattern, parallel to any one set of cut marks) |
- |
- |
|
- |
10.2(f) To ensure continuous contact with paint/coat
film, rub the tape firmly and remove air
bubbles under the tape, if any) |
- |
- |
|
- |
10.2(g)Within 60 to 120 s after sticking the tape,
remove it by seizing free end of the tape and
rapidly pulling it off at an angle close to 180°.) |
- |
- |
|
- |
10.2(h) Painting/Coating quality is considered as
acceptable, if no part of any 2 mm × 2 mm
square of paint/coat comes off the surface due
to pulling the tape) |
- |
- |
|
- |
11.2(Fire endurance test: The fire resisting record protection cabinets shall be considered to be conforming to the requirements of this standard if they successfully complete the fire endurance test (see B-3.1) and fire and impact test (see B 3.2).) |
- |
- |
|
- |
11.2.1(The fire resisting record protection cabinets shall
be considered to be conforming to the requirements of this standard, if they pass the fire endurance test (see B-3.1) and fire and impact test (see B-3.2) if the
contents (see B-1.1, B-3.1.1, B-3.2.1) kept in the
cabinets during the test are found usable.) |
- |
- |
|
- |
12.1(Marking:A metal plate showing type of cabinet together with the manufacturer’s name and the year of manufacture shall be fixed on the inner face of the door) |
- |
- |
|
- |
12.2(Marking on Keys: The keys shall be marked with an identification number
which shall not be the same as the serial number of the
cabinet.) |
- |
- |
|
- |
|
Complete
|
|
25 Oct, 2027 |
- - |
10 |
IS 302 : Part 2 : Sec 14 (2009) |
Safety of household and similar electrical appliances: Part 2 particular requirements: Sec 14 electric kitchen machines (First Revision) |
- |
-
|
50000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
6(Classification- IS 302-1 ) |
- |
0 |
|
- |
7.1(Marking- IS 302-1) |
- |
85 |
|
- |
7.3(Marking- IS 302-1) |
- |
85 |
|
- |
7.4(Marking- IS 302-1) |
- |
85 |
|
- |
7.6(Marking- IS 302-1) |
- |
85 |
|
- |
7.7(Marking- IS 302-1) |
- |
85 |
|
- |
7.8(Marking- IS 302-1) |
- |
85 |
|
- |
7.11(Marking- IS 302-1) |
- |
85 |
|
- |
7.12(Marking- IS 302-1) |
- |
85 |
|
- |
7.13(Marking- IS 302-1) |
- |
85 |
|
- |
7.14(Marking- IS 302-1) |
- |
85 |
|
- |
7.15(Marking- IS 302-1) |
- |
85 |
|
- |
7.101(Marking) |
- |
85 |
|
- |
8( Protection Against Electric Shock, IS 302-1) |
- |
1000 |
|
- |
10(Power Input and Current, IS 302-1) |
- |
5000 |
|
- |
11(Heating, IS 302-1) |
- |
5000 |
|
- |
13(Electrical Insulation and Leakage Current at Operating Temperature: Leakage current, IS 302-1) |
- |
500 |
|
- |
13(Electrical Insulation and Leakage Current at Operating Temperature: High Voltage, IS 302-1) |
- |
500 |
|
- |
14(Transient Over Voltages, IS 302-1) |
- |
4000 |
|
- |
15(Moisture Resistance, IS 302-1) |
- |
5000 |
|
- |
16(Electrical Insulation and Leakage Current at Operating Temperature: Leakage current, IS 302-1) |
- |
2500 |
|
- |
16(Electrical Insulation and Leakage Current at Operating Temperature: High Voltage, IS 302-1) |
- |
2500 |
|
- |
17(Overload protection of Transformers and Associated Circuits, IS 302-1) |
- |
5000 |
|
- |
19.1(Abnormal Operation, IS 302-1) |
- |
350 |
|
- |
19.9(Abnormal Operation, IS 302-1) |
- |
350 |
|
- |
19.7(Abnormal Operation, IS 302-1) |
- |
350 |
|
- |
19.8(Abnormal Operation, IS 302-1) |
- |
349.98 |
|
- |
19.101(Abnormal Operation) |
- |
350 |
|
- |
19.102(Abnormal Operation) |
- |
350 |
|
- |
20.1(Stability & Mechanical Hazards, IS 302-1) |
- |
60 |
|
- |
20.2(Stability & Mechanical Hazards, IS 302-1) |
- |
60 |
|
- |
20.101(Stability & Mechanical Hazards) |
- |
60 |
|
- |
20.102(Stability & Mechanical Hazards) |
- |
60 |
|
- |
20.103(Stability & Mechanical Hazards) |
- |
60 |
|
- |
20.104(Stability & Mechanical Hazards) |
- |
60 |
|
- |
20.105(Stability & Mechanical Hazards) |
- |
60 |
|
- |
20.106(Stability & Mechanical Hazards) |
- |
60 |
|
- |
20.107(Stability & Mechanical Hazards) |
- |
60 |
|
- |
20.108(Stability & Mechanical Hazards) |
- |
60 |
|
- |
20.109(Stability & Mechanical Hazards) |
- |
60 |
|
- |
20.110(Stability & Mechanical Hazards) |
- |
59.97 |
|
- |
20.111(Stability & Mechanical Hazards) |
- |
60 |
|
- |
20.112(Stability & Mechanical Hazards) |
- |
60 |
|
- |
20.113(Stability & Mechanical Hazards) |
- |
60 |
|
- |
20.114(Stability & Mechanical Hazards) |
- |
60 |
|
- |
20.115(Stability & Mechanical Hazards) |
- |
60 |
|
- |
21.1(Mechanical Strength, IS 302-1) |
- |
1000 |
|
- |
21.2(Mechanical Strength, IS 302-1) |
- |
1000 |
|
- |
22(Construction, IS 302-1) |
- |
350 |
|
- |
22.101(Construction) |
- |
350 |
|
- |
22.102(Construction) |
- |
350 |
|
- |
23.1(Internal Wiring, IS 302-1) |
- |
100 |
|
- |
23.2(Internal Wiring, IS 302-1) |
- |
100 |
|
- |
23.3(Internal Wiring, IS 302-1) |
- |
100 |
|
- |
23.4(Internal Wiring, IS 302-1) |
- |
100 |
|
- |
23.5(Internal Wiring, IS 302-1) |
- |
100 |
|
- |
23.6(Internal Wiring, IS 302-1) |
- |
100 |
|
- |
23.7(Internal Wiring, IS 302-1) |
- |
100 |
|
- |
23.8(Internal Wiring, IS 302-1) |
- |
100.02 |
|
- |
23.9(Internal Wiring, IS 302-1) |
- |
100 |
|
- |
23.10(Internal Wiring, IS 302-1) |
- |
100 |
|
- |
24.1(Components, IS 302-1) |
- |
100 |
|
- |
24.2(Components, IS 302-1) |
- |
100 |
|
- |
24.5(Components, IS 302-1) |
- |
100 |
|
- |
24.6(Components, IS 302-1) |
- |
100 |
|
- |
25.1(Supply Connection and External Flexible Cords, IS 302-1) |
- |
100 |
|
- |
25.5(Supply Connection and External Flexible Cords, IS 302-1) |
- |
100 |
|
- |
25.6(Supply Connection and External Flexible Cords, IS 302-1) |
- |
100 |
|
- |
25.7(Supply Connection and External Flexible Cords, IS 302-1) |
- |
100 |
|
- |
25.8(Supply Connection and External Flexible Cords, IS 302-1) |
- |
100 |
|
- |
25.1(Supply Connection and External Flexible Cords, IS 302-1) |
- |
100 |
|
- |
25.11(Supply Connection and External Flexible Cords, IS 302-1) |
- |
100 |
|
- |
25.12(Supply Connection and External Flexible Cords, IS 302-1) |
- |
100 |
|
- |
25.13(Supply Connection and External Flexible Cords, IS 302-1) |
- |
100 |
|
- |
25.14(Supply Connection and External Flexible Cords, IS 302-1) |
- |
100 |
|
- |
25.15(Supply Connection and External Flexible Cords, IS 302-1) |
- |
100 |
|
- |
25.16(Supply Connection and External Flexible Cords, IS 302-1) |
- |
100 |
|
- |
25.17(Supply Connection and External Flexible Cords, IS 302-1) |
- |
100 |
|
- |
25.18(Supply Connection and External Flexible Cords, IS 302-1) |
- |
100 |
|
- |
25.19(Supply Connection and External Flexible Cords, IS 302-1) |
- |
100 |
|
- |
25.2(Supply Connection and External Flexible Cords, IS 302-1) |
- |
100 |
|
- |
25.21(Supply Connection and External Flexible Cords, IS 302-1) |
- |
100 |
|
- |
25.22(Supply Connection and External Flexible Cords, IS 302-1) |
- |
100 |
|
- |
26(Terminals for External Conductors, IS 302-1) |
- |
100 |
|
- |
27(Provision for Earthing, IS 302-1) |
- |
250 |
|
- |
27.2(Provision for Earthing, IS 302-1) |
- |
250 |
|
- |
27.3(Provision for Earthing, IS 302-1) |
- |
250 |
|
- |
27.4(Provision for Earthing, IS 302-1) |
- |
250 |
|
- |
27.5(Provision for Earthing, IS 302-1) |
- |
250 |
|
- |
28(Screws & Connections, IS 302-1) |
- |
1000 |
|
- |
29.1(Clearances, Creepage distances and Solid Insulation, IS 302-1) |
- |
500 |
|
- |
29.2(Clearances, Creepage distances and Solid Insulation, IS 302-1) |
- |
500 |
|
- |
30.1(Resistance to Heat and Fire, IS 302-1) |
- |
1500 |
|
- |
30.2(Resistance to Heat and Fire, IS 302-1) |
- |
1500 |
|
- |
31(Resistance of Rusting, IS 302-1) |
- |
3000 |
|
- |
32(Radiation, Toxicity and similar Hazard IS 302-1) |
- |
100 |
|
- |
|
Complete
|
|
25 Oct, 2027 |
- - |
11 |
IS 302 : Part 2 : Sec 15 (2009) |
Safety of household and similar electrical appliances: Part 2 particular requirements: Sec 15 appliances for heating liquids (First Revision) |
- |
-
|
50000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
6.0(Classification) |
- |
0 |
|
- |
7(Marking and instructions) |
- |
1000 |
|
- |
8(Protection against live parts) |
- |
1000 |
|
- |
9(STARTING OF MOTOR-OPERATED APPLIANCES) |
- |
0 |
|
- |
10(POWER INPUT AND CURRENT) |
- |
5000 |
|
- |
11(HEATING) |
- |
5000 |
|
- |
13(LEAKAGE CURRENT AND ELECTRIC STRENGTH AT OPERATING TEMPERATURE) |
- |
1000 |
|
- |
14(TRANSIENT OVERVOLTAGES) |
- |
4000 |
|
- |
15(MOISTURE RESISTANCE) |
- |
5000 |
|
- |
16(LEAKAGE CURRENT AND ELECTRIC STRENGTH) |
- |
5000 |
|
- |
17(OVERLOAD PROTECTION OF TRANSFORMERS AND ASSOCIATED CIRCUITS) |
- |
5000 |
|
- |
18(ENDURANCE) |
- |
0 |
|
- |
19(ABNORMAL OPERATION) |
- |
2000 |
|
- |
20(STABILITY AND MECHANICAL HAZARDS) |
- |
1000 |
|
- |
21(MECHANICAL STRENGTH) |
- |
2000 |
|
- |
22(CONSTRUCTION) |
- |
1000 |
|
- |
23(INTERNAL WIRING) |
- |
1000 |
|
- |
24(COMPONENTS) |
- |
0 |
|
- |
25(SUPPLY CONNECTION AND EXTERNAL FLEXIBLE CORDS) |
- |
1000 |
|
- |
26(TERMINALS FOR EXTERNAL CONDUCTORS) |
- |
1000 |
|
- |
27(PROVISION FOR EARTHING) |
- |
1000 |
|
- |
28(SCREWS AND CONNECTIONS) |
- |
1000 |
|
- |
29(CLEARANCES, CREEPAGE DISTANCES AND SOLID INSULATION) |
- |
1000 |
|
- |
30(RESISTANCE TO HEAT AND FIRE) |
- |
3000 |
|
- |
31(RESISTANCE TO RUSTING) |
- |
3000 |
|
- |
32(RADIATION, TOXICITY AND SIMILAR HAZARDS) |
- |
0 |
|
- |
|
Complete
|
|
25 Oct, 2027 |
- - |
12 |
IS 302 : Part 2 : Sec 24 (1994) |
Safety of household and similar electrical appliances: Part 2 particular requirements: Sec 24 refrigerators, food - Freezers and ice - Makers |
- |
-
|
180000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
7.1 , 7.12, 7.14,7.15(Marking) |
- |
1500 |
|
- |
8.1, 8.1.1 & 8.2(Protection against access to live parts) |
- |
1200 |
|
- |
8.1.2(Protection against access to live parts) |
- |
1200 |
|
- |
8.1.3(Protection against access to live parts) |
- |
1200 |
|
- |
8.1.4(Protection against access to live parts) |
- |
1200 |
|
- |
8.1.5(Protection against access to live parts) |
- |
1200 |
|
- |
9(Starting of motor operated Appliances) |
- |
1700 |
|
- |
9.1(Startability Test) |
- |
1700 |
|
- |
9.2(Startability Test) |
- |
1700 |
|
- |
10.1,10.2
10.101,10.102( Input and Current) |
- |
10000 |
|
- |
11(TEMPERATURE RISE) |
- |
15000 |
|
- |
12,12.1,12.2 & 12.3(Heating) |
- |
1500 |
|
- |
13(ELECTRICAL INSULATION AND
LEAKAGE CURRENT AT OPERATING
TEMPERATURE) |
- |
10000 |
|
- |
14( RADIO AND TELEVISION
INTERFERENCE SUPPRESSION
) |
- |
15000 |
|
- |
15(Moisture resistance) |
- |
15000 |
|
- |
16 & 16.1(INSULATION RESISTANCE AND
ELECTRIC STRENGTH ( After the Humidity
Treatment )) |
- |
3000 |
|
- |
16.2(INSULATION RESISTANCE AND
ELECTRIC STRENGTH ( After the Humidity
Treatment )) |
- |
3000 |
|
- |
16.3 & table(INSULATION RESISTANCE AND
ELECTRIC STRENGTH ( After the Humidity
Treatment )) |
- |
3000 |
|
- |
16.4(INSULATION RESISTANCE AND
ELECTRIC STRENGTH ( After the Humidity
Treatment )) |
- |
3000 |
|
- |
17(Over load Protection ) |
- |
5000 |
|
- |
19(ABNORMAL OPERATION) |
- |
10000 |
|
- |
20.1(Stability and mechanical hazards) |
- |
10000 |
|
- |
20.2(Stability and mechanical hazards) |
- |
10000 |
|
- |
21.1(MECHANICAL STRENGTH) |
- |
5000 |
|
- |
21.2(MECHANICAL STRENGTH) |
- |
5000 |
|
- |
22.1(Constructions) |
- |
455 |
|
- |
22.2(Constructions) |
- |
455 |
|
- |
22.3(Constructions) |
- |
455 |
|
- |
22.4(Constructions) |
- |
455 |
|
- |
22.5(Constructions) |
- |
455 |
|
- |
22.6(Constructions) |
- |
455 |
|
- |
22.7 to 22.10(Constructions) |
- |
455 |
|
- |
22.11(Constructions) |
- |
455 |
|
- |
22.12(Constructions) |
- |
455 |
|
- |
22.13 to 22.33(Constructions) |
- |
455 |
|
- |
22.101 to 22.103(Constructions) |
- |
455 |
|
- |
23.1 & 23.2(Internal wiring) |
- |
500 |
|
- |
23.3(Internal wiring) |
- |
500 |
|
- |
23.4(Internal wiring) |
- |
500 |
|
- |
23.5 to 23.8(Internal wiring) |
- |
500 |
|
- |
24.1(Components) |
- |
0 |
|
- |
24.2 ,24.3,24.5 & 24.6(Components) |
- |
0 |
|
- |
25.1(Supply connection and external flexible cords) |
- |
1000 |
|
- |
25.2(Supply connection and external flexible cords) |
- |
1000 |
|
- |
25.3(Supply connection and external flexible cords) |
- |
1000 |
|
- |
25.4(Supply connection and external flexible cords) |
- |
1000 |
|
- |
25.6(Supply connection and external flexible cords) |
- |
1000 |
|
- |
25.7 to 25.13(Supply connection and external flexible cords) |
- |
1000 |
|
- |
26.1 to 26.8(Terminals for external conductors) |
- |
1700 |
|
- |
26.9(Terminals for external conductors) |
- |
1700 |
|
- |
26.10 & 26.13(Terminals for external conductors) |
- |
1700 |
|
- |
27.1 to 27.4(Provision for earthing) |
- |
3000 |
|
- |
27.5(Provision for earthing) |
- |
3000 |
|
- |
28.1, Table No.-14(Screws and connections) |
- |
2500 |
|
- |
28.2 to 28.4(Screws and connections) |
- |
2500 |
|
- |
29.1 and table 2(creepage and Clearances distances ) |
- |
1000 |
|
- |
29.2 & 29.3(Clearances, creepage distances ) |
- |
4000 |
|
- |
30.1(Resistance to heat and fire) |
- |
3700 |
|
- |
30.2(Resistance to heat and fire) |
- |
3700 |
|
- |
30.3(Resistance to heat and fire) |
- |
3700 |
|
- |
31(Resistance to rusting) |
- |
10000 |
|
- |
32(Radiation, toxicity and similar hazards) |
- |
0 |
|
- |
|
Complete
|
|
25 Oct, 2027 |
- - |
13 |
IS 302 : Part 2 : Sec 6 (2009) |
Safety of household and similar electrical appliances: Part 2 particular requirements: Sec 6 cooking ranges, hobs, ovens and similar appliances (First Revision) |
- |
-
|
50000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
6.0(Classification) |
- |
0 |
|
- |
7.0(Marking and instructions) |
- |
1000 |
|
- |
8.0(Protection against access to live part test) |
- |
1000 |
|
- |
9.0(Starting of motor-operated appliances test) |
- |
0 |
|
- |
10.0(Power Input and current test) |
- |
5000 |
|
- |
11.0(Heating test) |
- |
5000 |
|
- |
13.0(Leakage current and electric strength test) |
- |
4000 |
|
- |
14.0(Transient voltages) |
- |
5000 |
|
- |
15.0(Moisture Resistance) |
- |
5000 |
|
- |
16.0(Leakage current and electric strength test) |
- |
4000 |
|
- |
17.0(Overload protection of transformers test) |
- |
2000 |
|
- |
18.0(Endurance test) |
- |
0 |
|
- |
19.0(Abnormal Operations) |
- |
1000 |
|
- |
20.0(Stability and Mechanical Hazards) |
- |
2000 |
|
- |
21.0(Mechanical Strength) |
- |
1000 |
|
- |
22.0(Construction verification related tests) |
- |
1000 |
|
- |
23.0(Internal wiring) |
- |
1000 |
|
- |
24.0(Components) |
- |
0 |
|
- |
25.0(Supply connections and External Flexible Cords) |
- |
1000 |
|
- |
26.0(Terminal for External Conductors) |
- |
1000 |
|
- |
27.0(Provision for Earthing) |
- |
1000 |
|
- |
28.0(Screws and connections) |
- |
1000 |
|
- |
29.0(Clearances and Creepage distances and solid insulation) |
- |
1000 |
|
- |
30.0(Resistance to heat and fire) |
- |
3000 |
|
- |
31.0(Resistance to rusting) |
- |
3000 |
|
- |
32.0(Radiation, Toxicity and Similar hazards) |
- |
100 |
|
- |
|
Complete
|
|
25 Oct, 2027 |
- - |
14 |
IS 302 : Part 2 : Sec 21 (2018) |
Safety of household and similar electrical appliances: Part 2 particular requirements: Sec 21 stationary storage type electric water heaters (Second Revision) |
- |
-
|
45000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
7.0(Marking and Instructions) |
- |
1000 |
|
- |
6.0(Classification) |
- |
0 |
|
- |
8.0(Protection against access to live parts) |
- |
1000 |
|
- |
10.0(Input and Current) |
- |
2000 |
|
- |
11.0(Heating) |
- |
2000 |
|
- |
13.0(Leakage Current and electric strength at operating temperature) |
- |
4000 |
|
- |
14.0(Transient Overvoltage) |
- |
3000 |
|
- |
15.0(Moisture resistance) |
- |
5000 |
|
- |
16.0(Leakage current and Electric strength (After Humidity (Environmental) Treatment)) |
- |
4000 |
|
- |
17.0(Overload Protection of transformer and associated circuit) |
- |
2000 |
|
- |
19.0(Abnormal Operation) |
- |
2000 |
|
- |
20.0(Stability and mechanical hazards) |
- |
1500 |
|
- |
21.0(Mechanical Strength) |
- |
2000 |
|
- |
22.0(Construction) |
- |
1000 |
|
- |
23.0(Internal Wiring) |
- |
500 |
|
- |
25.0(Supply Connection and External Flexible Cords) |
- |
1000 |
|
- |
26.0(Terminals for external conductors) |
- |
1000 |
|
- |
27.0(Provision For Earthing) |
- |
2000 |
|
- |
28.0(Screws and Connections) |
- |
1000 |
|
- |
29.0(Creepage Distances and Clearances) |
- |
2000 |
|
- |
30.0(Resistance To Heat and Fire) |
- |
5000 |
|
- |
31.0(Resistance To Rusting) |
- |
2000 |
|
- |
|
Complete
|
|
25 Oct, 2027 |
- - |
15 |
IS 2082 (2018) |
Stationary storage type electric water heaters - Specification (Fifth Revision) |
- |
-
|
60000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
7(Marking) |
- |
2000 |
|
- |
6(Classification ) |
- |
1000 |
|
- |
(Cl.8 of IS 302-2-21:2011)(Protection Against Access to Live Parts) |
- |
1000 |
|
- |
(Cl.10 of IS 302-2-21: 2011)(Power Input & Current) |
- |
2000 |
|
- |
(Cl.11 of 302-2-21:2011)(Heating) |
- |
2000 |
|
- |
(Cl.13 of IS 302-2-21:2011)(Leakage Current ) |
- |
4000 |
|
- |
(Cl.14ofIS302-2-21:2011)(Transient Over Voltages) |
- |
3000 |
|
- |
(Cl.15 of IS 302-2-21-2011)(Moisture Resistance) |
- |
5000 |
|
- |
(Cl.17 of IS 302-2-21:2011)(Overload protection of transformers & associated circuits) |
- |
2000 |
|
- |
(Cl.19 of IS 302-2-21:2011)(Abnormal Operation) |
- |
2000 |
|
- |
(Cl.20 of IS 302-2-21:2011)(Stability & Mechanical Hazards) |
- |
1500 |
|
- |
(Cl.21ofIS302-2-21:2011)(Mechanical strength) |
- |
2000 |
|
- |
(Cl.22 Of
IS 302-2-21:2011)(Construction) |
- |
1000 |
|
- |
(Cl. 23 of IS 302-2-21: 2011)(Internal Wiring
) |
- |
500 |
|
- |
(Cl.24ofIS302-2Â21:2011)(Component) |
- |
0 |
|
- |
(Cl.25 of IS 302-2-21:2011)(Supply Connection & External Flexible Cords) |
- |
1000 |
|
- |
(Cl.26 of IS 302-2-21: 2011)(Terminals for External Conductors) |
- |
1000 |
|
- |
(Cl.27 of IS 302-2-21:2011)(Provision for Earthing) |
- |
2000 |
|
- |
(Cl.28 of IS 302-2-21:2011)(Screws & Connections) |
- |
1000 |
|
- |
(Cl.29ofIS302-2-21:2011)(Clearances, Creepage Distances and Solid Insulation) |
- |
2000 |
|
- |
(Cl.30 of IS 302-2-21:2011)(Resistance to Heat & Fire) |
- |
5000 |
|
- |
Cl.31 of IS 302-2-21:2018(Resistance to Rusting) |
- |
2000 |
|
- |
(Cl.15 of IS 2082:2018)(Verification of the Rated Capacity) |
- |
5000 |
|
- |
(Cl.16 of IS 2082:2018)(Standing Loss per 24 Hours) |
- |
1000 |
|
- |
(Cl.17 of IS 2082:2018)(Hot Water Output) |
- |
3000 |
|
- |
(Cl.18 of IS 2082:2018)( Reheating Time) |
- |
2000 |
|
- |
(Cl.19 of IS 2082:2018)(Mixing Factor) |
- |
1000 |
|
- |
(Cl.20 of IS 2082:2018)(Deviation of Dial Calibration) |
- |
1000 |
|
- |
(Cl.21 of IS 2082:2018)(Cyclic Temperature Variation) |
- |
1000 |
|
- |
Cl.22 of IS 2082:2018(Finish) |
- |
0 |
|
- |
|
Complete
|
|
25 Oct, 2027 |
- - |
16 |
IS 1475 : Part 1 (2001) |
Self - Contained drinking water coolers - Specification: Part 1 energy consumption and performance (Third Revision) |
- |
-
|
40000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
6.1(COMPONENTS AND THEIR MATERIALS) |
- |
59 |
|
- |
6.2(COMPONENTS AND THEIR MATERIALS) |
- |
59 |
|
- |
6.3(COMPONENTS AND THEIR MATERIALS) |
- |
59 |
|
- |
6.4(COMPONENTS AND THEIR MATERIALS) |
- |
59 |
|
- |
6.5(COMPONENTS AND THEIR MATERIALS) |
- |
59 |
|
- |
6.6(COMPONENTS AND THEIR MATERIALS) |
- |
59 |
|
- |
6.7(COMPONENTS AND THEIR MATERIALS) |
- |
59 |
|
- |
6.8(COMPONENTS AND THEIR MATERIALS) |
- |
59 |
|
- |
6.9(COMPONENTS AND THEIR MATERIALS) |
- |
59 |
|
- |
6.11(COMPONENTS AND THEIR MATERIALS) |
- |
59 |
|
- |
6.12(COMPONENTS AND THEIR MATERIALS) |
- |
59 |
|
- |
6.13(COMPONENTS AND THEIR MATERIALS) |
- |
59 |
|
- |
6.14(COMPONENTS AND THEIR MATERIALS) |
- |
59 |
|
- |
6.15(COMPONENTS AND THEIR MATERIALS) |
- |
59 |
|
- |
6.16(COMPONENTS AND THEIR MATERIALS) |
- |
59 |
|
- |
6.17(COMPONENTS AND THEIR MATERIALS) |
- |
59 |
|
- |
7.7.1(Insulation Resistance) |
- |
5000 |
|
- |
7.7.2(High Voltage Test) |
- |
5000 |
|
- |
7.7.3(Cooling capacity rating test) |
- |
10000 |
|
- |
7.7.4(Maximum operating conditions) |
- |
10000 |
|
- |
7.8.2(Performance test) |
- |
4500 |
|
- |
|
Complete
|
|
25 Oct, 2027 |
- - |
17 |
IS 10322 : Part 5 : Sec 7 (2017) |
Luminaires: Part 5 particular requirements: Sec 7 lighting chains (First Revision) |
- |
-
|
45000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
20.4(General Test Requireements) |
- |
0 |
|
-- |
20.5(Classification of Luminaires') |
- |
0 |
|
-- |
20.6(Marking) |
- |
1000 |
|
-- |
20.7(Construction) |
- |
2000 |
|
-- |
20.8(Creepage Distance and Clearances) |
- |
2000 |
|
-- |
20.9(Provision for earthing) |
- |
5000 |
|
-- |
20.10(Terminals) |
- |
5000 |
|
-- |
20.11(External & Internal Wiring) |
- |
1000 |
|
-- |
20.12(Protection against electric shock) |
- |
1000 |
|
-- |
20.13(Endurance Tests and Thermal Tests) |
- |
3000 |
|
-- |
20.14(Resistance to Dust & Moisture) |
- |
10000 |
|
-- |
20.15(Insulation Resistance and Electric Strength) |
- |
10000 |
|
-- |
20.16(Resistance to Heat , fire and tracking) |
- |
5000 |
|
-- |
|
Complete
|
|
25 Oct, 2027 |
- - |
18 |
IS 10322 : Part 5 : Sec 5 (2013) |
Luminaires: Part 5 particular requirements: Sec 5 floodlights (First Revision) |
- |
-
|
45000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
4(General Test Requireements) |
- |
0 |
|
-- |
5(Classification of Luminaires') |
- |
0 |
|
-- |
6.0(Marking) |
- |
1000 |
|
-- |
7.0(Construction) |
- |
2000 |
|
-- |
8.0(Creepage Distance and Clearances) |
- |
2000 |
|
-- |
9.0(Provision for earthing) |
- |
5000 |
|
-- |
10.0(Terminals) |
- |
5000 |
|
-- |
11.0(External & Internal Wiring) |
- |
1000 |
|
-- |
12.0(Protection against electric shock) |
- |
1000 |
|
-- |
13.0(Endurance Tests and Thermal Tests) |
- |
3000 |
|
-- |
14.0(Resistance to Dust & Moisture) |
- |
10000 |
|
-- |
15.0(Insulation Resistance and Electric Strength) |
- |
10000 |
|
-- |
16.0(Resistance to Heat , fire and tracking) |
- |
5000 |
|
-- |
17.0(Photometric Test) |
- |
0 |
|
-- |
|
Complete
|
|
25 Oct, 2027 |
- - |
19 |
IS 10322 : PART 5 : SEC 3 (2012) |
Luminaires: Part 5 particular requirements: Sec 3 luminaires for road and street lighting (First Revision) |
- |
-
|
45000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
4(General Test Requireements) |
- |
0 |
|
-- |
5(Classification of Luminaires') |
- |
0 |
|
-- |
6.0(Marking) |
- |
1000 |
|
-- |
7.0(Construction) |
- |
2000 |
|
-- |
8.0(Creepage Distance and Clearances) |
- |
2000 |
|
-- |
9.0(Provision for earthing) |
- |
5000 |
|
-- |
10.0(Terminals) |
- |
5000 |
|
-- |
11.0(External & Internal Wiring) |
- |
1000 |
|
-- |
12.0(Protection against electric shock) |
- |
1000 |
|
-- |
13.0(Endurance Tests and Thermal Tests) |
- |
3000 |
|
-- |
14.0(Resistance to Dust & Moisture) |
- |
10000 |
|
-- |
15.0(Insulation Resistance and Electric Strength) |
- |
10000 |
|
-- |
16.0(Resistance to Heat , fire and tracking) |
- |
5000 |
|
-- |
17.0(Photometric Test) |
- |
0 |
|
-- |
|
Complete
|
|
25 Oct, 2027 |
- - |
20 |
IS 10322 : Part 5 : Sec 1 (2012) |
Luminaires: Part 5 particular requirements: Sec 1 fixed general purpose luminaires (First Revision) |
- |
-
|
45000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
4(General Test Requireements) |
- |
0 |
|
-- |
5(Classification of Luminaires') |
- |
0 |
|
-- |
6.0(Marking) |
- |
1000 |
|
-- |
7.0(Construction) |
- |
2000 |
|
-- |
8.0(Creepage Distance and Clearances) |
- |
2000 |
|
-- |
9.0(Provision for earthing) |
- |
5000 |
|
-- |
10.0(Terminals) |
- |
5000 |
|
-- |
11.0(External & Internal Wiring) |
- |
1000 |
|
-- |
12.0(Protection against electric shock) |
- |
1000 |
|
-- |
13.0(Endurance Tests and Thermal Tests) |
- |
3000 |
|
-- |
14.0(Resistance to Dust & Moisture) |
- |
10000 |
|
-- |
15.0(Insulation Resistance and Electric Strength) |
- |
10000 |
|
-- |
16.0(Resistance to Heat , fire and tracking) |
- |
5000 |
|
-- |
|
Complete
|
|
25 Oct, 2027 |
- - |
21 |
IS 616 (2017) |
Audio, video and similar electronic apparatus - Safety requirements (Fifth Revision) |
- |
-
|
65000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
5(Marking and instructions) |
- |
1000 |
|
-- |
6(Hazardous radiations) |
- |
0 |
|
-- |
7(Heating under normal operating conditions) |
- |
1000 |
|
-- |
8(Constructional requirements with regard to the protection against electric shock) |
- |
8500 |
|
-- |
9(Electric shock hazard under normal operating conditions) |
- |
5000 |
|
-- |
10(Insulation requirements) |
- |
10000 |
|
-- |
11(Fault conditions) |
- |
6000 |
|
-- |
12(Mechanical strength) |
- |
5000 |
|
-- |
13(CLEARANCES and CREEPAGE DISTANCES) |
- |
3000 |
|
-- |
14(Components) |
- |
0 |
|
-- |
15(TERMINALS) |
- |
7500 |
|
-- |
16(External flexible cords) |
- |
1500 |
|
-- |
17(Electrical connections and mechanical fixings) |
- |
1500 |
|
-- |
18(Mechanical strength of picture tubes and protection against the effects of implosion) |
- |
0 |
|
-- |
19(Stability and mechanical hazards) |
- |
5000 |
|
-- |
20(Resistance to fire) |
- |
10000 |
|
-- |
|
Complete
|
|
25 Oct, 2027 |
- - |
22 |
IS 16333 : Part 3 (2017) |
Mobile phone handsets: Part 3 indian language support for mobile phone handsets - Specific requirements (First Revision) |
- |
-
|
10000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
5.1(Inputting of text) |
- |
5000 |
|
-- |
5.2(Message Readability) |
- |
5000 |
|
-- |
|
Complete
|
|
25 Oct, 2027 |
- - |
23 |
IS 16242 : Part 1 (2014) |
Uninterruptible power systems (UPS): Part 1 general and safety requirements for UPS |
- |
-
|
70000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
4.5(Components) |
- |
99.98 |
|
-- |
4.6(Power interface) |
- |
7000 |
|
-- |
4.7(Marking & instructions) |
- |
2500 |
|
-- |
5.1(Protection against shock and energy hazards) |
- |
3000 |
|
-- |
5.2(Requirement of auxiliary circuits) |
- |
2000 |
|
-- |
5.3(Protective earthing and bonding) |
- |
7000 |
|
-- |
5.4(AC and DC power isolation) |
- |
250 |
|
-- |
5.5(Over current and earth fault condition) |
- |
1500 |
|
-- |
5.6(Safety interlocks) |
- |
200 |
|
-- |
5.7(CLEARANCES, CREEPAGE DISTANCES AND SOLID INSULATION) |
- |
2500 |
|
-- |
6.1(Wiring, connections and supply) |
- |
2500 |
|
-- |
6.2(Connection to power) |
- |
3500 |
|
-- |
6.3(Wiring terminals for external power conductors) |
- |
2500 |
|
-- |
7.1(Enclosure) |
- |
500 |
|
-- |
7.2(STABILITY) |
- |
5500 |
|
-- |
7.3(MECHANICAL STRENGTH) |
- |
3500 |
|
-- |
7.4(Construction details) |
- |
750 |
|
-- |
7.5(Resistance to fire) |
- |
2500 |
|
-- |
7.6(Battery location) |
- |
3000 |
|
-- |
7.7(Temperature rise) |
- |
5700 |
|
-- |
8.1(General procision for earth leakage) |
- |
3500 |
|
-- |
8.2(Electric Strength) |
- |
3500 |
|
-- |
8.3(Abnormal operating and fault conditions) |
- |
4000 |
|
-- |
9.0(Connection to telecommunication networks) |
- |
3000 |
|
-- |
|
Complete
|
|
25 Oct, 2027 |
- - |
24 |
IS 16102 : Part 1 (2012) |
Self - Ballasted led lamps for general lighting services: Part 1 safety requirements |
- |
-
|
25000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
5(Marking) |
- |
500 |
|
-- |
6(Interchangeability) |
- |
200 |
|
-- |
7(Protection against accidental contact with live parts) |
- |
1200 |
|
-- |
8(Insulation Resistance and Electric Strength) |
- |
10000 |
|
-- |
9(MECHANICAL STRENGTH) |
- |
2000 |
|
-- |
10(cap temperature) |
- |
5000 |
|
-- |
11(Resistance to Heat) |
- |
1200 |
|
-- |
12(Resistance to Flame and Ignition) |
- |
2000 |
|
-- |
13(Fault conditions) |
- |
2000 |
|
-- |
14(Creepage distance and clearances) |
- |
600 |
|
-- |
|
Complete
|
|
25 Oct, 2027 |
- - |
25 |
IS 15885 : Part 2 : Sec 13 (2012) |
Safety of lamp controlgear: Part 2 particular requirements: Sec 13 d.c. or a.c. supplied electronic controlgear for led modules |
- |
-
|
45000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
7(Marking) |
- |
1200 |
|
-- |
8(Protection against accidental contact with live parts) |
- |
2000 |
|
-- |
9(Terminals) |
- |
1000 |
|
-- |
10(PROVISION FOR EARTHING) |
- |
8000 |
|
-- |
11(MOISTURE RESISTANCE) |
- |
8000 |
|
-- |
12(Electric Strength) |
- |
6000 |
|
-- |
13(Thermal endurance test for winding of ballasts) |
- |
0 |
|
-- |
14(Fault conditions) |
- |
8000 |
|
-- |
15(Transformer heating) |
- |
5000 |
|
-- |
16(Construction) |
- |
1000 |
|
-- |
17(Creepage distance and clearances) |
- |
1200 |
|
-- |
18(Screws, current carrying parts and connections) |
- |
1000 |
|
-- |
19(Resistance to heat, fire and tracking) |
- |
1800 |
|
-- |
20(Resistance to corrosion) |
- |
800 |
|
-- |
|
Complete
|
|
25 Oct, 2027 |
- - |
26 |
IS 16103 : Part 1 (2012) |
Led modules for general lighting: Part 1 safety requirements |
- |
-
|
50000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
7(Marking) |
- |
2000 |
|
-- |
8(Terminals) |
- |
3000 |
|
-- |
9(PROVISION FOR EARTHING) |
- |
8000 |
|
-- |
10(Protection against accidental contact with live parts) |
- |
7000 |
|
-- |
11(Mositure Resistance and Insulation) |
- |
12000 |
|
-- |
12(Electric Strength) |
- |
8000 |
|
-- |
13(Fault conditions) |
- |
3000 |
|
-- |
15(Construction) |
- |
500 |
|
-- |
16(Creepage distance and clearances) |
- |
1200 |
|
-- |
17(Screws, current carrying parts and connections) |
- |
1000 |
|
-- |
18(Resistance to heat, fire and tracking) |
- |
2800 |
|
-- |
19(Resistance to corrosion) |
- |
1500 |
|
-- |
|
Complete
|
|
25 Oct, 2027 |
- - |
27 |
IS/IEC 60529 (2001) |
Degrees of protection provided by enclosures (IP Code) |
- |
-
|
26000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Cl-5(Degrees of protection against access to hazardous parts and against solid foreign objects indicated by the first characteristic numeral) |
- |
12000 |
|
NIL |
Cl-6(Degrees of protectlon against ingress of water indicated 'by the second characteristic numeral) |
- |
8000 |
|
NIL |
Cl-10(Marking) |
- |
6000 |
|
NIL |
|
Complete
|
|
25 Oct, 2027 |
- - |
28 |
IS 302 : Part 1 (2008) |
Safety of household and similar electrical appliances: Part 1 general requirements (Sixth Revision) |
- |
-
|
55000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
7(Marking and instructions) |
- |
12000 |
|
- |
8.1.1(Protection against live parts in all positions) |
- |
500 |
|
- |
8.1.2(Protection against live parts in openings) |
- |
500 |
|
- |
8.1.4(Protection against live parts against protective impedance) |
- |
1200 |
|
- |
9(Starting of motor operation test requirements and tests) |
- |
0 |
|
- |
10.1(Power input) |
- |
2000 |
|
- |
10.2(Current input) |
- |
2000 |
|
- |
11.1(General) |
- |
200 |
|
- |
11.2(General) |
- |
1800 |
|
- |
11.3(Heating) |
- |
3000 |
|
- |
13.1(General) |
- |
100 |
|
- |
13.2(Leakage current at operating temperature) |
- |
1200 |
|
- |
13.3(Electric Strength at operating temperature) |
- |
2500 |
|
- |
14(Transient Over Voltages) |
- |
2000 |
|
- |
15.0(General) |
- |
200 |
|
- |
15.1(Ingress Protection test other than IPX0 (IP test)) |
- |
3000 |
|
- |
15.2(Spillage Test) |
- |
800 |
|
- |
15.3(Humidity Test) |
- |
6000 |
|
- |
16.0(General) |
- |
100 |
|
- |
16.1(General) |
- |
200 |
|
- |
16.2(Leakage Current (after Clause 15)) |
- |
800 |
|
- |
16.3(Electric Strength (after clause 15 and 16.2)) |
- |
2000 |
|
- |
17(Over Load Protection of Transformers and associated circuits) |
- |
500 |
|
- |
18(Endurance Test requirements and tests) |
- |
0 |
|
- |
19(Abnormal Operation) |
- |
3000 |
|
- |
20(Stability test) |
- |
3500 |
|
- |
21(Mechanical Strength Test) |
- |
2000 |
|
- |
22(Construction verification related test) |
- |
500 |
|
- |
23(General) |
- |
100 |
|
- |
24(Components) |
- |
500 |
|
- |
25(Supply connection and external flexible cords) |
- |
1200 |
|
- |
26(Terminals for external conductors) |
- |
500 |
|
- |
27(Provision for earthing) |
- |
3000 |
|
- |
28(Screw test and connections) |
- |
2500 |
|
- |
29(clearance, creepage distances and solid insulation) |
- |
1500 |
|
- |
30.1(Ball pressure test) |
- |
2000 |
|
- |
30.2(Glow Wire Test) |
- |
1200 |
|
- |
30.2(Needle Flame Test) |
- |
1200 |
|
- |
31(Resistance to Rusting) |
- |
500 |
|
- |
32(Radiation Toxicity and Similar Hazards) |
- |
0 |
|
- |
15.4 (b)(Cold impact) |
- |
0 |
|
- |
|
Complete
|
|
25 Oct, 2027 |
- - |
29 |
IS 13252 : Part 1 (2010) |
Information technology equipment - Safety: Part 1 general requirements (Second Revision) |
- |
-
|
66000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
1.5(Components) |
- |
0 |
|
-- |
1.6(Power interface .) |
- |
6500 |
|
-- |
1.7(Markings and instructions) |
- |
2000 |
|
-- |
2.1(Protection from electric shock and energy hazards) |
- |
1500 |
|
-- |
2.2(SELV circuits) |
- |
500 |
|
-- |
2.3(TNV circuits) |
- |
500 |
|
-- |
2.4(Limited current circuits) |
- |
2500 |
|
-- |
2.5(Limited power sources .) |
- |
2000 |
|
-- |
2.6(Provisions for earthing and bonding) |
- |
4000 |
|
-- |
2.7(Overcurrent and earth fault protection in primary circuits) |
- |
100 |
|
-- |
2.8(Safety interlocks) |
- |
100 |
|
-- |
2.9(Electrical insulation) |
- |
8000 |
|
--- |
2.10(Clearances, creepage distances and distances through insulation) |
- |
500 |
|
-- |
3.1(General) |
- |
500 |
|
-- |
3.2(Connection to a mains supply) |
- |
100 |
|
-- |
3.3(Wiring terminals for connection of external conductors) |
- |
350 |
|
-- |
3.4(Disconnection from the mains supply) |
- |
500 |
|
-- |
3.5(Interconnection of equipment) |
- |
750 |
|
-- |
4.1(Stability) |
- |
350 |
|
-- |
4.2(Mechanical strength) |
- |
2000 |
|
-- |
4.3(Design and construction) |
- |
1500 |
|
-- |
4.4(Protection against hazardous moving parts) |
- |
200 |
|
-- |
4.5(Thermal requirements) |
- |
5000 |
|
-- |
4.6(Openings in enclosures) |
- |
500 |
|
-- |
4.7(Resistance to fire) |
- |
1200 |
|
-- |
5.1(Touch current and protective conductor curren) |
- |
2500 |
|
-- |
5.2(Electric strength) |
- |
3500 |
|
-- |
5.3(Abnormal operating and fault conditions) |
- |
4500 |
|
-- |
6.1(Protection of telecommunication network service persons, and users of other equipment connected to the network, from hazards in the equipment) |
- |
100 |
|
-- |
6.2(Protection of equipment users from overvoltages on networks telecommunication) |
- |
1500 |
|
-- |
6.3(Protection of the telecommunication wiring system from overheating) |
- |
2000 |
|
-- |
7.1(General) |
- |
1000 |
|
-- |
7.2(Protection of cable distribution system service persons, and users of other equipment connected to the system, from hazardous voltages in the equipment) |
- |
3500 |
|
-- |
7.3(Protection of equipment users from overvoltages on the cable distribution system) |
- |
3000 |
|
-- |
7.4(Insulation between primary circuits and cable distribution systems) |
- |
3000 |
|
-- |
|
Complete
|
|
25 Oct, 2027 |
- - |
30 |
IS 550 : Part 1 (2014) |
Safes: Part 1 specification (Fifth Revision) |
- |
-
|
380000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Cl. 4 Table 1(CLASSIFICATIONS) |
- |
5000 |
|
- |
Cl. 5 Table 2(DIMENSIONS AND SIZES) |
- |
5000 |
|
- |
Cl. 5 Table 10(DIMENSIONS AND SIZES) |
- |
5000 |
|
- |
Cl. 7 (DESIGNATIONS) |
- |
5000 |
|
- |
Cl. 8.1(Body) |
- |
5000 |
|
- |
Cl. 8.3(Door) |
- |
5000 |
|
- |
Cl. 8.4.1(Hinges) |
- |
5000 |
|
- |
Cl. 8.4.2(Bolts) |
- |
5000 |
|
- |
Cl. 8.5 Table 3(Handles) |
- |
5000 |
|
- |
Cl. 8.6.1(Locks (Type)) |
- |
5000 |
|
- |
Cl. 8.6.2(Locks (Levers)) |
- |
25000 |
|
- |
Cl. 8.6.3(Tests for locks) |
- |
25000 |
|
- |
Cl. 8.6.4(Keys) |
- |
5000 |
|
- |
Cl. 8.6.5(Unpickability) |
- |
5000 |
|
- |
Cl. 8.6.6(Non-interchangeability) |
- |
5000 |
|
- |
Cl. 8.7(Automatic Relocking Device) |
- |
10000 |
|
- |
Cl. 9(INTERNAL FIXTURES) |
- |
5000 |
|
- |
Cl. 10(Painting) |
- |
5000 |
|
- |
Cl. 10(Painting) |
- |
5000 |
|
- |
Cl. 11.1(Marking of Safes) |
- |
5000 |
|
- |
Cl. 11.2( Marking on Keys) |
- |
5000 |
|
- |
Cl. 11.3(BIS Certification Marking) |
- |
5000 |
|
- |
|
Complete
|
|
25 Oct, 2027 |
- - |