1 |
IS 14246 (2024) |
CONTINUOUSLY PRE-PAINTED GALVANIZED STEEL SHEETS AND STRIPS - SPECIFICATION Second Revision |
ALL |
35000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Cl-4.1(Steel Base) |
- |
5000 |
|
35000/- for Class-1, 40000/- for Class-2, 45000/- for Class-3, 60000/- for class-4 |
Cl-4.2(Metallic Coating) |
- |
2000 |
|
35000/- for Class-1, 40000/- for Class-2, 45000/- for Class-3, 60000/- for class-4 |
Cl-4.3(Organic Coating) |
- |
2000 |
|
35000/- for Class-1, 40000/- for Class-2, 45000/- for Class-3, 60000/- for class-4 |
Cl-4.4(Dry Film Thickness) |
- |
2000 |
|
35000/- for Class-1, 40000/- for Class-2, 45000/- for Class-3, 60000/- for class-4 |
Cl-4.5(Profiles) |
- |
0 |
|
35000/- for Class-1, 40000/- for Class-2, 45000/- for Class-3, 60000/- for class-4 |
Cl-5(Classification of durability of organic coating) |
- |
0 |
|
35000/- for Class-1, 40000/- for Class-2, 45000/- for Class-3, 60000/- for class-4 |
Cl-6.1(Sampling of Test Specimen) |
- |
0 |
|
35000/- for Class-1, 40000/- for Class-2, 45000/- for Class-3, 60000/- for class-4 |
Cl-6.2.3(Bend Test) |
- |
1000 |
|
35000/- for Class-1, 40000/- for Class-2, 45000/- for Class-3, 60000/- for class-4 |
Cl-6.3.1(Pencil Hardness Test) |
- |
1000 |
|
35000/- for Class-1, 40000/- for Class-2, 45000/- for Class-3, 60000/- for class-4 |
Cl-6.4(Impact Resistance Test) |
- |
1000 |
|
35000/- for Class-1, 40000/- for Class-2, 45000/- for Class-3, 60000/- for class-4 |
Cl-6.5(Cross Hatch Test) |
- |
1000 |
|
35000/- for Class-1, 40000/- for Class-2, 45000/- for Class-3, 60000/- for class-4 |
Cl-6.6(Solvent Resistance Test) |
- |
4000 |
|
35000/- for Class-1, 40000/- for Class-2, 45000/- for Class-3, 60000/- for class-4 |
Cl-6.7(Other Tests) |
- |
0 |
|
35000/- for Class-1, 40000/- for Class-2, 45000/- for Class-3, 60000/- for class-4 |
Cl-7.3.1(Gloss) |
- |
2000 |
|
35000/- for Class-1, 40000/- for Class-2, 45000/- for Class-3, 60000/- for class-4 |
Cl-7.3.2(Colour) |
- |
1000 |
|
35000/- for Class-1, 40000/- for Class-2, 45000/- for Class-3, 60000/- for class-4 |
Cl-8.1, Table-4 (i)(Undercut at scribed lines) |
- |
10000 |
|
35000/- for Class-1, 40000/- for Class-2, 45000/- for Class-3, 60000/- for class-4 |
Cl-8.1, Table-4 (ii)(Corrosion of the base metal) |
- |
0 |
|
35000/- for Class-1, 40000/- for Class-2, 45000/- for Class-3, 60000/- for class-4 |
Cl-8.1, Table-4 (iii)(Blistering) |
- |
0 |
|
35000/- for Class-1, 40000/- for Class-2, 45000/- for Class-3, 60000/- for class-4 |
Cl-8.2 Table 5 (i)(Undercut at scribed lines) |
- |
10000 |
|
35000/- for Class-1, 40000/- for Class-2, 45000/- for Class-3, 60000/- for class-4 |
Cl-8.2 Table 5 (ii)(Blistering) |
- |
0 |
|
35000/- for Class-1, 40000/- for Class-2, 45000/- for Class-3, 60000/- for class-4 |
Cl-9.1(The nominal thickness of sheets) |
- |
0 |
|
35000/- for Class-1, 40000/- for Class-2, 45000/- for Class-3, 60000/- for class-4 |
Cl-9.2(The case of strips) |
- |
1000 |
|
35000/- for Class-1, 40000/- for Class-2, 45000/- for Class-3, 60000/- for class-4 |
Cl-9.3(Mass of each pack) |
- |
0 |
|
35000/- for Class-1, 40000/- for Class-2, 45000/- for Class-3, 60000/- for class-4 |
Cl-9.4.1(Tolerances on thickness sheets and strips) |
- |
1000 |
|
35000/- for Class-1, 40000/- for Class-2, 45000/- for Class-3, 60000/- for class-4 |
Cl-9.4.2(Width) |
- |
1000 |
|
35000/- for Class-1, 40000/- for Class-2, 45000/- for Class-3, 60000/- for class-4 |
Cl-9.4.3(Length) |
- |
1000 |
|
35000/- for Class-1, 40000/- for Class-2, 45000/- for Class-3, 60000/- for class-4 |
Cl-9.4.4(Mass) |
- |
1000 |
|
35000/- for Class-1, 40000/- for Class-2, 45000/- for Class-3, 60000/- for class-4 |
Cl-10.1(Camber) |
- |
1000 |
|
35000/- for Class-1, 40000/- for Class-2, 45000/- for Class-3, 60000/- for class-4 |
Cl-10.2(Deviation from Squareness (Out-of Square) |
- |
1000 |
|
35000/- for Class-1, 40000/- for Class-2, 45000/- for Class-3, 60000/- for class-4 |
Cl-10.3(Deviation from Flatness) |
- |
1000 |
|
35000/- for Class-1, 40000/- for Class-2, 45000/- for Class-3, 60000/- for class-4 |
Cl-14(Marking) |
- |
0 |
|
35000/- for Class-1, 40000/- for Class-2, 45000/- for Class-3, 60000/- for class-4 |
As per Cl.4.1(Carbon) |
- |
500 |
|
35000/- for Class-1, 40000/- for Class-2, 45000/- for Class-3, 60000/- for class-4 |
As per Cl.4.1(Sulphur) |
- |
500 |
|
35000/- for Class-1, 40000/- for Class-2, 45000/- for Class-3, 60000/- for class-4 |
As per Cl.4.1(Phosphorus) |
- |
500 |
|
35000/- for Class-1, 40000/- for Class-2, 45000/- for Class-3, 60000/- for class-4 |
As per Cl.4.1(Manganese) |
- |
500 |
|
35000/- for Class-1, 40000/- for Class-2, 45000/- for Class-3, 60000/- for class-4 |
As per Cl.4.1(Nitrogen) |
- |
500 |
|
35000/- for Class-1, 40000/- for Class-2, 45000/- for Class-3, 60000/- for class-4 |
As per Cl.4.1(Silicon) |
- |
500 |
|
35000/- for Class-1, 40000/- for Class-2, 45000/- for Class-3, 60000/- for class-4 |
As per Cl.4.1(Aluminium) |
- |
500 |
|
35000/- for Class-1, 40000/- for Class-2, 45000/- for Class-3, 60000/- for class-4 |
As per Cl.4.1(Vanadium) |
- |
500 |
|
35000/- for Class-1, 40000/- for Class-2, 45000/- for Class-3, 60000/- for class-4 |
As per Cl.4.1(Niobium) |
- |
500 |
|
35000/- for Class-1, 40000/- for Class-2, 45000/- for Class-3, 60000/- for class-4 |
As per Cl.4.1(Copper) |
- |
500 |
|
35000/- for Class-1, 40000/- for Class-2, 45000/- for Class-3, 60000/- for class-4 |
As per Cl.4.1(Titanium) |
- |
500 |
|
35000/- for Class-1, 40000/- for Class-2, 45000/- for Class-3, 60000/- for class-4 |
As per Cl.4.1(Boron) |
- |
500 |
|
35000/- for Class-1, 40000/- for Class-2, 45000/- for Class-3, 60000/- for class-4 |
Cl-4.1(Steel Base) |
- |
- |
|
- |
Cl-4.2(Metallic Coating) |
- |
- |
|
- |
Cl-4.3(Organic Coating) |
- |
- |
|
- |
Cl-4.4(Dry Film Thickness) |
- |
- |
|
- |
Cl-4.5(Profiles) |
- |
- |
|
- |
Cl-5(Classification of durability of organic coating) |
- |
- |
|
- |
Cl-6.1(Sampling of Test Specimen) |
- |
- |
|
- |
Cl-6.2.3(Bend Test) |
- |
- |
|
- |
Cl-6.3.1(Pencil Hardness Test) |
- |
- |
|
- |
Cl-6.4(Impact Resistance Test) |
- |
- |
|
- |
Cl-6.5(Cross Hatch Test) |
- |
- |
|
- |
Cl-6.6(Solvent Resistance Test) |
- |
- |
|
- |
Cl-6.7(Other Tests) |
- |
- |
|
- |
Cl-7.3.1(Gloss) |
- |
- |
|
- |
Cl-7.3.2(Colour) |
- |
- |
|
- |
Cl-8.1, Table-4 (i)(Undercut at scribed lines) |
- |
- |
|
- |
Cl-8.1, Table-4 (ii)(Corrosion of the base metal) |
- |
- |
|
- |
Cl-8.1, Table-4 (iii)(Blistering) |
- |
- |
|
- |
Cl-8.2 Table 5 (i)(Undercut at scribed lines) |
- |
- |
|
- |
Cl-8.2 Table 5 (ii)(Blistering) |
- |
- |
|
- |
Cl-9.1(The nominal thickness of sheets) |
- |
- |
|
- |
Cl-9.2(The case of strips) |
- |
- |
|
- |
Cl-9.3(Mass of each pack) |
- |
- |
|
- |
Cl-9.4.1(Tolerances on thickness sheets and strips) |
- |
- |
|
- |
Cl-9.4.2(Width) |
- |
- |
|
- |
Cl-9.4.3(Length) |
- |
- |
|
- |
Cl-9.4.4(Mass) |
- |
- |
|
- |
Cl-10.1(Camber) |
- |
- |
|
- |
Cl-10.2(Deviation from Squareness (Out-of Square) |
- |
- |
|
- |
Cl-10.3(Deviation from Flatness) |
- |
- |
|
- |
Cl-14(Marking) |
- |
- |
|
- |
As per Cl.4.1(Carbon) |
- |
- |
|
- |
As per Cl.4.1(Sulphur) |
- |
- |
|
- |
As per Cl.4.1(Phosphorus) |
- |
- |
|
- |
As per Cl.4.1(Manganese) |
- |
- |
|
- |
As per Cl.4.1(Nitrogen) |
- |
- |
|
- |
As per Cl.4.1(Silicon) |
- |
- |
|
- |
As per Cl.4.1(Aluminium) |
- |
- |
|
- |
As per Cl.4.1(Vanadium) |
- |
- |
|
- |
As per Cl.4.1(Niobium) |
- |
- |
|
- |
As per Cl.4.1(Copper) |
- |
- |
|
- |
As per Cl.4.1(Titanium) |
- |
- |
|
- |
As per Cl.4.1(Boron) |
- |
- |
|
- |
|
25 Feb, 2027 |
- Included w.e.f 20.06.2025 |
2 |
IS 18800 (2023) |
Stainless steel feeding bottle for infants -- Specification |
- |
29900 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Cl.4.1(Carbon - IS 228 and its parts or any other intrumental/chemical methods) |
- |
0 |
|
- |
Cl.4.1(Silicon - IS 228 and its parts or any other intrumental/chemical methods) |
- |
0 |
|
- |
Cl.4.1(Manganese - IS 228 and its parts or any other intrumental/chemical methods) |
- |
0 |
|
- |
Cl.4.1(Nickel - IS 228 and its parts or any other intrumental/chemical methods) |
- |
0 |
|
- |
Cl.4.1(Chromium - IS 228 and its parts or any other intrumental/chemical methods) |
- |
0 |
|
- |
Cl.4.1(Sulphur - IS 228 and its parts or any other intrumental/chemical methods) |
- |
0 |
|
- |
Cl.4.1(Phosphorous - IS 228 and its parts or any other intrumental/chemical methods) |
- |
0 |
|
- |
Cl.4.1(Nitrogen - IS 228 and its parts or any other intrumental/chemical methods) |
- |
0 |
|
- |
Cl.4.1(Molybdenum - IS 228 and its parts or any other intrumental/chemical methods) |
- |
0 |
|
- |
Cl.4.1(Copper - IS 228 and its parts or any other intrumental/chemical methods) |
- |
0 |
|
- |
Cl.4.1(Other Elements - IS 228 and its parts or any other intrumental/chemical methods) |
- |
0 |
|
- |
5.1.1(Description) |
- |
0 |
|
- |
5.1.2(Manufacture, Workmanship, Finish and Appearance) |
- |
0 |
|
- |
5.1.3(Wall Thickness) |
- |
0 |
|
- |
5.1.4(Capacity) |
- |
0 |
|
- |
5.2(Mechanical Requirements) |
- |
0 |
|
- |
5.3.1(Leakage Test) |
- |
0 |
|
- |
5.3.2(Drop Test) |
- |
0 |
|
- |
5.3.3(Compressive Deformation Resistance) |
- |
0 |
|
- |
5.3.4(Permanency of Pigments of Printed Container) |
- |
0 |
|
- |
5.1.1(Description) |
- |
0 |
|
- |
5.1.2(Manufacture, Workmanship, Finish and Appearance) |
- |
0 |
|
- |
5.1.3(Wall Thickness) |
- |
0 |
|
- |
5.1.4(Capacity) |
- |
0 |
|
- |
5.2(Mechanical Requirements) |
- |
0 |
|
- |
5.3.1(Leakage Test) |
- |
0 |
|
- |
5.3.2(Drop Test) |
- |
0 |
|
- |
5.3.3(Compressive Deformation Resistance) |
- |
0 |
|
- |
5.3.4(Permanency of Pigments of Printed Container) |
- |
0 |
|
- |
Cl.5.3.4(Permanency of Pigments - Annex D of IS 18800) |
- |
0 |
|
- |
|
25 Feb, 2027 |
- Included w.e.f 12.06.2025 |
3 |
IS 5405 (2025) |
Disposable Sanitary Napkin/Panty Liner/Maternity Pad/Period Panty - Specification ( Third Revision ) |
- |
14900 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
3.1(Cover/Top sheet) |
- |
0 |
|
- |
3.2(Absorbent core) |
- |
0 |
|
- |
3.3(Barrier or bottom sheet) |
- |
0 |
|
- |
4.1(Types) |
- |
0 |
|
- |
4.2(shapes) |
- |
0 |
|
- |
5(Sizes) |
- |
0 |
|
- |
Cl. 5 Table-1(Type) |
- |
0 |
|
- |
Cl. 5 Table-1(Size class) |
- |
0 |
|
- |
Cl. 5 Table-1(Length (Absorbent core only)) |
- |
0 |
|
- |
Cl. 5 Table-1(Width (Absorbent core only)) |
- |
0 |
|
- |
6.1(Manufacture, workmanship and finish) |
- |
0 |
|
- |
6.2(Manufacture, workmanship and finish) |
- |
0 |
|
- |
7.1(pH value (IS 1390)) |
- |
0 |
|
- |
7.2(Ability to withstand Pressure after absorption) |
- |
0 |
|
- |
7.2(Ability to withstand Pressure after absorption - Leakage) |
- |
0 |
|
- |
7.3.1(Total Viable count) |
- |
0 |
|
- |
7.3.2(Staphylococcus aureus) |
- |
0 |
|
- |
7.4(Biocompatibility evaluation - Cytotoxicity (IS/ISO 10993 P-5)) |
- |
0 |
|
- |
7.4(Biocompatibility evaluation - Irritation (IS 17932 P-7)) |
- |
0 |
|
- |
7.4(Biocompatibility evaluation - skin Sensitization (Optional) (IS 17932 P-6)) |
- |
0 |
|
- |
7.5(Phthalate test) |
- |
0 |
|
- |
7.6(Compostability (Optional) (IS/ISO 17088)) |
- |
0 |
|
- |
7.7(Anti bacterial activity value (Optional) (IS/ISO 20743)) |
- |
0 |
|
- |
3.1(Cover/Top Sheet (non sterile gauze)) |
- |
0 |
|
- |
3.1(Cover/Top Sheet (sterile gauze)) |
- |
0 |
|
- |
5(Size) |
- |
0 |
|
- |
|
25 Feb, 2027 |
- Included w.e.f 12.06.2025 |
4 |
IS 3735 (1996) |
Canvas Shoes, Rubber Sole |
all |
18000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Cl.4.5 Consolidation Test
IS 3400 (Part 5) : 1986 (From the quarter, cut a strip of 25.0 ± 0.5 mm width along the leagth of the boot
and of sufficient length to permit separation over a length of 75 mm. Carry out the test on two test pieces (one from each odd) at the rate of traverse of 100± 10mm per minute in accordance with IS 3400 (Part 5): 1986 or Static Dead Load
Method as given in Annex C. The individual adhesion value for consolidation test shall not be less than 30N (3.0 kgf) for each of the teat piecea (see Note
under 4.4).') |
- |
18000 |
|
- |
4.1.1 Upper, Sl No. (i) of Table 1(The upper shall consist of over layer of cotton, manmade or blended
conforming' to the requirements given in Sl No. (i) of Table 1 as an overlayer and cotton drill conforming to the
requirements given in Sl No. (ii) of Table 1, as an inner layer or lining. The two fabrics shall be firmly adhered together with rubber compound. ) |
- |
18000 |
|
- |
Cl.4.1.1.1 Colour fastness(The dyed fabrics prescribed in 4.1.1 shall be fast todaylight and mechanical washing. Fastness to daylight
shall be of rating 4 or better, when tested in accordance with IS 686 : 1985 or IS 2454: 1985. However in case of dispute the method prescribed in IS 686 : 1985
shall be considered as referee method.) |
- |
18000 |
|
- |
Cl.4.1.2 Binding Material(IS 1954 : 1990)
(IS1969 : 1985)(Cotton tape NEWAR used as binding material shall conform to the requirements prescribed in col 3 of
Table 2, when tested in accordance with the methods referred to in col 4 of the table.) |
- |
18000 |
|
- |
Cl.4.1.2.1
Anmex B.(Cotton, manmade or blended shall be used as binding material.'
'Coloured cotton tapes shall have fastness to day light of rating as and if agreed
to between the purchaser and the supplier when tested in accordance with IS 686 :
1985. The black tapes shall be free from sulphur dyes when tested in accordance
with Annex B.') |
- |
18000 |
|
- |
Cl.4.1.3.1( Sewing thread cotton, manmade or blended shall be used for stitching of
upper. For cotton variety thread shall conform to variety No. 28 of IS 1720.
Polyester variety thread shall conform to variety No. 9 of IS 9543. Any other suitable thread shall have breaking load not less than above referred
requirement of specification.
Sewing thread cotton, manmade or blended shall be used for binding of upper. For cotton variety thread shall conform to variety No. 32 of IS 1720. Polyester variety thread shall conform to variety No. 5 of IS 9543.
Any other suitable thread shall have breaking load not less than above referred
requirement of specification.') |
- |
18000 |
|
- |
Cl.4.1.3.2 (IS 2454 : 1985)
IS 765 : 1979
IS 971 : 1966( The colour of the threads shall be as agreedto between the purchaser and the supplier. The dyed threads shall conform to the following requirements or IS 686 : 1985'.) |
- |
18000 |
|
- |
Cl.4.1.4(.Brass, steel or aluminium eyelets of 7.5 mm diameter and wall thickness 0.30 to
0.35 mm shall be used.') |
- |
18000 |
|
- |
Cl.4.1.5 Laces(
The shoes shall be provided with fabric braided laces
either matching the shade of the upper or black or The length of the lace shall be 60 ± 3 cm ) |
- |
18000 |
|
- |
Cl.4.1.5 Laces(and shallhave the breaking strength of not less than 250 N when tested between 18 cm grips in accordance with
IS 1969 : 1985, the rate of traverse of power actuated grip being 300 mm/min.) |
- |
18000 |
|
- |
Cl.4.1.5 Laces
Annex B(In case the laces are black,
the same shall pass the test for freedom from sulpher
dyes when tested in accordance with Annex B. The
two ends of the lace shall be provided with suitable
metal or plastic tips.) |
- |
18000 |
|
- |
Cl.4.1.6 Rubber Components(The rubber components shall conform to the requirements given in Table 4, when tested from finished boots.However in case it is not possible to cut the test pieces from the made up boots then 4.1.5.3 of IS
13695 : 1993 shall be followed.') |
- |
18000 |
|
- |
Cl.4.1.6.2 Ageing
col 4 of Table 5.(The shoes shall be also aged at 70 ± 1°C for 168 h, on completion of which the test pieces taken from the shoes shall conform to the physical requirements
prescribed in col 4 of Table 5. ) |
- |
18000 |
|
- |
Cl.4.1.6.2 Ageing
(None of the rubber components of the shoes shall show any sign of tackiness or crack developed after ageing, when examined visually) |
- |
0 |
|
- |
Cl.4.1.6.3 Thickness of components
in Table 6.(Individual components of the shoes shall comply with
the thickness and material requirements prescribed
in Table 6.) |
- |
18000 |
|
- |
CL.4.2 Shape and Design
IS 1638 : 1969(Cl 4.2.1 The shoes shall be made according to design
and pattern as agreed to between the purchaser and
the supplier. Size and fittings of the shoes shall be
in accordance with IS 1638 : 1969 unless otherwise
specified by the purchaser.) |
- |
18000 |
|
- |
Cl.4.2.2( The recommended design of canvas shoes is
shown in Fig. 1.) |
- |
18000 |
|
- |
Cl.4.3 Construction
Cl 4.3.1( The upper shall be stitched on a lock stitch machine and the number of stitches shall be 30 to
40 per dm.) |
- |
18000 |
|
- |
Cl.'4.3.2( Back of the upper shall be reinforced with a strip of upper material when
there is a seam.') |
- |
18000 |
|
- |
Cl.4.3.3( The counter shall be stitched at the back, set from bottom of lining and bound flat on top edge
with white/scoured binding material cut in bias and formed as a tape. T ) |
- |
0 |
|
- |
Cl.4.3.3(he number of stitches shall be
30 to 40 per decimetre. The counter binding shall
meet the binding of the upper at the centre top edge
of the heel.) |
- |
0 |
|
- |
Cl.4.3.3(The edges of quarter shall be bound with
dyed cotton binding material or matching to the colour
of the upper, cut in bias and formed as a tape.) |
- |
0 |
|
- |
Cl.4.3.4 (The vantp shall be strengthened with a rubber
toe-cap (see Fig. 1).) |
- |
18000 |
|
- |
Cl.4.3.5( Five pairs of eyelets shall be fitted in each
shoe. The eyelets shall be properly clenched without
any distortion. It shall properly match the colour of
the upper canvas, or as agreed to between the purchaser
and the supplier.) |
- |
0 |
|
- |
Cl.4.3.6( The shoes shall be free from folds, wrinkles in the upper, blisters, embedded foreign matters and
excessive surface markings. In appearance, general workmanship, finish and all other respects, not defined
in the standard, the shoes shall be similar to the
sample approved by the purchaser, if any) |
- |
0 |
|
- |
CL.4.3.7( The soles shall be of even substance and ofone layer only.) |
- |
0 |
|
- |
Cl.4.3.8( A rubber foxing shall be fixed all round the sole and heel. The colour shall be as agreed to between the purchaser and the supplier. ) |
- |
0 |
|
- |
Cl.4.3.8(The foxing, not less
than 18 mm wide, shall not extend beyond the edges of the sole at the bottom) |
- |
18000 |
|
- |
Cl.4.4 Adhesion Test(From the upper-foxing portion where it is adhered to the canvas, parallel to the waist of sole, cut a strip of length 100 mm and width 8 mm. Separate out
the plies initially by breaking the bond to a length of about 75 mm. Carry out the test on two specimens in accordance with IS 3400 (Part 5) : 1986. There
shall be no further separation within 1 minute at a load of 1 kg for each of the two specimens.) |
- |
18000 |
|
- |
CL.4.6 Mass(The mass of one pair of finished shoes of size 8 shall not exceed 750 g with an increase or decrease of 25 g for each bigger or smaller size respectively) |
- |
0 |
|
- |
Cl.4.5 Consolidation Test
IS 3400 (Part 5) : 1986 (From the quarter, cut a strip of 25.0 ± 0.5 mm width along the leagth of the boot
and of sufficient length to permit separation over a length of 75 mm. Carry out the test on two test pieces (one from each odd) at the rate of traverse of 100± 10mm per minute in accordance with IS 3400 (Part 5): 1986 or Static Dead Load
Method as given in Annex C. The individual adhesion value for consolidation test shall not be less than 30N (3.0 kgf) for each of the teat piecea (see Note
under 4.4).') |
- |
0 |
|
- |
4.1.1 Upper, Sl No. (i) of Table 1(The upper shall consist of over layer of cotton, manmade or blended
conforming' to the requirements given in Sl No. (i) of Table 1 as an overlayer and cotton drill conforming to the
requirements given in Sl No. (ii) of Table 1, as an inner layer or lining. The two fabrics shall be firmly adhered together with rubber compound. ) |
- |
0 |
|
- |
Cl.4.1.1.1 Colour fastness(The dyed fabrics prescribed in 4.1.1 shall be fast todaylight and mechanical washing. Fastness to daylight
shall be of rating 4 or better, when tested in accordance with IS 686 : 1985 or IS 2454: 1985. However in case of dispute the method prescribed in IS 686 : 1985
shall be considered as referee method.) |
- |
0 |
|
- |
Cl.4.1.2 Binding Material(IS 1954 : 1990)
(IS1969 : 1985)(Cotton tape NEWAR used as binding material shall conform to the requirements prescribed in col 3 of
Table 2, when tested in accordance with the methods referred to in col 4 of the table.) |
- |
0 |
|
- |
Cl.4.1.2.1
Anmex B.(Cotton, manmade or blended shall be used as binding material.'
'Coloured cotton tapes shall have fastness to day light of rating as and if agreed
to between the purchaser and the supplier when tested in accordance with IS 686 :
1985. The black tapes shall be free from sulphur dyes when tested in accordance
with Annex B.') |
- |
0 |
|
- |
Cl.4.1.3.1( Sewing thread cotton, manmade or blended shall be used for stitching of
upper. For cotton variety thread shall conform to variety No. 28 of IS 1720.
Polyester variety thread shall conform to variety No. 9 of IS 9543. Any other suitable thread shall have breaking load not less than above referred
requirement of specification.
Sewing thread cotton, manmade or blended shall be used for binding of upper. For cotton variety thread shall conform to variety No. 32 of IS 1720. Polyester variety thread shall conform to variety No. 5 of IS 9543.
Any other suitable thread shall have breaking load not less than above referred
requirement of specification.') |
- |
0 |
|
- |
Cl.4.1.3.2 (IS 2454 : 1985)
IS 765 : 1979
IS 971 : 1966( The colour of the threads shall be as agreedto between the purchaser and the supplier. The dyed threads shall conform to the following requirements or IS 686 : 1985'.) |
- |
0 |
|
- |
Cl.4.1.4(.Brass, steel or aluminium eyelets of 7.5 mm diameter and wall thickness 0.30 to
0.35 mm shall be used.') |
- |
0 |
|
- |
Cl.4.1.5 Laces(
The shoes shall be provided with fabric braided laces
either matching the shade of the upper or black or The length of the lace shall be 60 ± 3 cm ) |
- |
0 |
|
- |
Cl.4.1.5 Laces(and shallhave the breaking strength of not less than 250 N when tested between 18 cm grips in accordance with
IS 1969 : 1985, the rate of traverse of power actuated grip being 300 mm/min.) |
- |
0 |
|
- |
Cl.4.1.5 Laces
Annex B(In case the laces are black,
the same shall pass the test for freedom from sulpher
dyes when tested in accordance with Annex B. The
two ends of the lace shall be provided with suitable
metal or plastic tips.) |
- |
0 |
|
- |
Cl.4.1.6 Rubber Components(The rubber components shall conform to the requirements given in Table 4, when tested from finished boots.However in case it is not possible to cut the test pieces from the made up boots then 4.1.5.3 of IS
13695 : 1993 shall be followed.') |
- |
0 |
|
- |
Cl.4.1.6.2 Ageing
col 4 of Table 5.(The shoes shall be also aged at 70 ± 1°C for 168 h, on completion of which the test pieces taken from the shoes shall conform to the physical requirements
prescribed in col 4 of Table 5. ) |
- |
0 |
|
- |
Cl.4.1.6.2 Ageing
(None of the rubber components of the shoes shall show any sign of tackiness or crack developed after ageing, when examined visually) |
- |
0 |
|
- |
Cl.4.1.6.3 Thickness of components
in Table 6.(Individual components of the shoes shall comply with
the thickness and material requirements prescribed
in Table 6.) |
- |
0 |
|
- |
CL.4.2 Shape and Design
IS 1638 : 1969(Cl 4.2.1 The shoes shall be made according to design
and pattern as agreed to between the purchaser and
the supplier. Size and fittings of the shoes shall be
in accordance with IS 1638 : 1969 unless otherwise
specified by the purchaser.) |
- |
0 |
|
- |
Cl.4.2.2( The recommended design of canvas shoes is
shown in Fig. 1.) |
- |
0 |
|
- |
Cl.4.3 Construction
Cl 4.3.1( The upper shall be stitched on a lock stitch machine and the number of stitches shall be 30 to
40 per dm.) |
- |
0 |
|
- |
Cl.'4.3.2( Back of the upper shall be reinforced with a strip of upper material when
there is a seam.') |
- |
0 |
|
- |
Cl.4.3.3( The counter shall be stitched at the back, set from bottom of lining and bound flat on top edge
with white/scoured binding material cut in bias and formed as a tape. T ) |
- |
0 |
|
- |
Cl.4.3.3(he number of stitches shall be
30 to 40 per decimetre. The counter binding shall
meet the binding of the upper at the centre top edge
of the heel.) |
- |
0 |
|
- |
Cl.4.3.3(The edges of quarter shall be bound with
dyed cotton binding material or matching to the colour
of the upper, cut in bias and formed as a tape.) |
- |
0 |
|
- |
Cl.4.3.4 (The vantp shall be strengthened with a rubber
toe-cap (see Fig. 1).) |
- |
0 |
|
- |
Cl.4.3.5( Five pairs of eyelets shall be fitted in each
shoe. The eyelets shall be properly clenched without
any distortion. It shall properly match the colour of
the upper canvas, or as agreed to between the purchaser
and the supplier.) |
- |
0 |
|
- |
Cl.4.3.6( The shoes shall be free from folds, wrinkles in the upper, blisters, embedded foreign matters and
excessive surface markings. In appearance, general workmanship, finish and all other respects, not defined
in the standard, the shoes shall be similar to the
sample approved by the purchaser, if any) |
- |
0 |
|
- |
CL.4.3.7( The soles shall be of even substance and ofone layer only.) |
- |
18000 |
|
- |
Cl.4.3.8( A rubber foxing shall be fixed all round the sole and heel. The colour shall be as agreed to between the purchaser and the supplier. ) |
- |
0 |
|
- |
Cl.4.3.8(The foxing, not less
than 18 mm wide, shall not extend beyond the edges of the sole at the bottom) |
- |
0 |
|
- |
Cl.4.4 Adhesion Test(From the upper-foxing portion where it is adhered to the canvas, parallel to the waist of sole, cut a strip of length 100 mm and width 8 mm. Separate out
the plies initially by breaking the bond to a length of about 75 mm. Carry out the test on two specimens in accordance with IS 3400 (Part 5) : 1986. There
shall be no further separation within 1 minute at a load of 1 kg for each of the two specimens.) |
- |
0 |
|
- |
CL.4.6 Mass(The mass of one pair of finished shoes of size 8 shall not exceed 750 g with an increase or decrease of 25 g for each bigger or smaller size respectively) |
- |
0 |
|
- |
Cl.4.5 Consolidation Test
IS 3400 (Part 5) : 1986 (From the quarter, cut a strip of 25.0 ± 0.5 mm width along the leagth of the boot
and of sufficient length to permit separation over a length of 75 mm. Carry out the test on two test pieces (one from each odd) at the rate of traverse of 100± 10mm per minute in accordance with IS 3400 (Part 5): 1986 or Static Dead Load
Method as given in Annex C. The individual adhesion value for consolidation test shall not be less than 30N (3.0 kgf) for each of the teat piecea (see Note
under 4.4).') |
- |
0 |
|
- |
4.1.1 Upper, Sl No. (i) of Table 1(The upper shall consist of over layer of cotton, manmade or blended
conforming' to the requirements given in Sl No. (i) of Table 1 as an overlayer and cotton drill conforming to the
requirements given in Sl No. (ii) of Table 1, as an inner layer or lining. The two fabrics shall be firmly adhered together with rubber compound. ) |
- |
0 |
|
- |
Cl.4.1.1.1 Colour fastness(The dyed fabrics prescribed in 4.1.1 shall be fast todaylight and mechanical washing. Fastness to daylight
shall be of rating 4 or better, when tested in accordance with IS 686 : 1985 or IS 2454: 1985. However in case of dispute the method prescribed in IS 686 : 1985
shall be considered as referee method.) |
- |
0 |
|
- |
Cl.4.1.2 Binding Material(IS 1954 : 1990)
(IS1969 : 1985)(Cotton tape NEWAR used as binding material shall conform to the requirements prescribed in col 3 of
Table 2, when tested in accordance with the methods referred to in col 4 of the table.) |
- |
0 |
|
- |
Cl.4.1.2.1
Anmex B.(Cotton, manmade or blended shall be used as binding material.'
'Coloured cotton tapes shall have fastness to day light of rating as and if agreed
to between the purchaser and the supplier when tested in accordance with IS 686 :
1985. The black tapes shall be free from sulphur dyes when tested in accordance
with Annex B.') |
- |
0 |
|
- |
Cl.4.1.3.1( Sewing thread cotton, manmade or blended shall be used for stitching of
upper. For cotton variety thread shall conform to variety No. 28 of IS 1720.
Polyester variety thread shall conform to variety No. 9 of IS 9543. Any other suitable thread shall have breaking load not less than above referred
requirement of specification.
Sewing thread cotton, manmade or blended shall be used for binding of upper. For cotton variety thread shall conform to variety No. 32 of IS 1720. Polyester variety thread shall conform to variety No. 5 of IS 9543.
Any other suitable thread shall have breaking load not less than above referred
requirement of specification.') |
- |
0 |
|
- |
Cl.4.1.3.2 (IS 2454 : 1985)
IS 765 : 1979
IS 971 : 1966( The colour of the threads shall be as agreedto between the purchaser and the supplier. The dyed threads shall conform to the following requirements or IS 686 : 1985'.) |
- |
0 |
|
- |
Cl.4.1.4(.Brass, steel or aluminium eyelets of 7.5 mm diameter and wall thickness 0.30 to
0.35 mm shall be used.') |
- |
0 |
|
- |
Cl.4.1.5 Laces(
The shoes shall be provided with fabric braided laces
either matching the shade of the upper or black or The length of the lace shall be 60 ± 3 cm ) |
- |
0 |
|
- |
Cl.4.1.5 Laces(and shallhave the breaking strength of not less than 250 N when tested between 18 cm grips in accordance with
IS 1969 : 1985, the rate of traverse of power actuated grip being 300 mm/min.) |
- |
0 |
|
- |
Cl.4.1.5 Laces
Annex B(In case the laces are black,
the same shall pass the test for freedom from sulpher
dyes when tested in accordance with Annex B. The
two ends of the lace shall be provided with suitable
metal or plastic tips.) |
- |
0 |
|
- |
Cl.4.1.6 Rubber Components(The rubber components shall conform to the requirements given in Table 4, when tested from finished boots.However in case it is not possible to cut the test pieces from the made up boots then 4.1.5.3 of IS
13695 : 1993 shall be followed.') |
- |
0 |
|
- |
Cl.4.1.6.2 Ageing
col 4 of Table 5.(The shoes shall be also aged at 70 ± 1°C for 168 h, on completion of which the test pieces taken from the shoes shall conform to the physical requirements
prescribed in col 4 of Table 5. ) |
- |
0 |
|
- |
Cl.4.1.6.2 Ageing
(None of the rubber components of the shoes shall show any sign of tackiness or crack developed after ageing, when examined visually) |
- |
0 |
|
- |
Cl.4.1.6.3 Thickness of components
in Table 6.(Individual components of the shoes shall comply with
the thickness and material requirements prescribed
in Table 6.) |
- |
0 |
|
- |
CL.4.2 Shape and Design
IS 1638 : 1969(Cl 4.2.1 The shoes shall be made according to design
and pattern as agreed to between the purchaser and
the supplier. Size and fittings of the shoes shall be
in accordance with IS 1638 : 1969 unless otherwise
specified by the purchaser.) |
- |
0 |
|
- |
Cl.4.2.2( The recommended design of canvas shoes is
shown in Fig. 1.) |
- |
0 |
|
- |
Cl.4.3 Construction
Cl 4.3.1( The upper shall be stitched on a lock stitch machine and the number of stitches shall be 30 to
40 per dm.) |
- |
0 |
|
- |
Cl.'4.3.2( Back of the upper shall be reinforced with a strip of upper material when
there is a seam.') |
- |
0 |
|
- |
Cl.4.3.3( The counter shall be stitched at the back, set from bottom of lining and bound flat on top edge
with white/scoured binding material cut in bias and formed as a tape. T ) |
- |
18000 |
|
- |
Cl.4.3.3(he number of stitches shall be
30 to 40 per decimetre. The counter binding shall
meet the binding of the upper at the centre top edge
of the heel.) |
- |
0 |
|
- |
Cl.4.3.3(The edges of quarter shall be bound with
dyed cotton binding material or matching to the colour
of the upper, cut in bias and formed as a tape.) |
- |
0 |
|
- |
Cl.4.3.4 (The vantp shall be strengthened with a rubber
toe-cap (see Fig. 1).) |
- |
0 |
|
- |
Cl.4.3.5( Five pairs of eyelets shall be fitted in each
shoe. The eyelets shall be properly clenched without
any distortion. It shall properly match the colour of
the upper canvas, or as agreed to between the purchaser
and the supplier.) |
- |
18000 |
|
- |
Cl.4.3.6( The shoes shall be free from folds, wrinkles in the upper, blisters, embedded foreign matters and
excessive surface markings. In appearance, general workmanship, finish and all other respects, not defined
in the standard, the shoes shall be similar to the
sample approved by the purchaser, if any) |
- |
18000 |
|
- |
CL.4.3.7( The soles shall be of even substance and ofone layer only.) |
- |
0 |
|
- |
Cl.4.3.8( A rubber foxing shall be fixed all round the sole and heel. The colour shall be as agreed to between the purchaser and the supplier. ) |
- |
18000 |
|
- |
Cl.4.3.8(The foxing, not less
than 18 mm wide, shall not extend beyond the edges of the sole at the bottom) |
- |
0 |
|
- |
Cl.4.4 Adhesion Test(From the upper-foxing portion where it is adhered to the canvas, parallel to the waist of sole, cut a strip of length 100 mm and width 8 mm. Separate out
the plies initially by breaking the bond to a length of about 75 mm. Carry out the test on two specimens in accordance with IS 3400 (Part 5) : 1986. There
shall be no further separation within 1 minute at a load of 1 kg for each of the two specimens.) |
- |
0 |
|
- |
CL.4.6 Mass(The mass of one pair of finished shoes of size 8 shall not exceed 750 g with an increase or decrease of 25 g for each bigger or smaller size respectively) |
- |
18000 |
|
- |
4.8(Adhesion ) |
- |
0 |
|
- |
4.7(Consolidation test ) |
- |
0 |
|
- |
4.6(Mass ) |
- |
0 |
|
- |
4.5(Finish ) |
- |
18000 |
|
- |
4.4(Contruction ) |
- |
18000 |
|
- |
4.3(Leg Height ) |
- |
18000 |
|
- |
4.2(Design ) |
- |
18000 |
|
- |
4.1.6.2(Thickness of components ) |
- |
18000 |
|
- |
4.1.6.2(Ageing) |
- |
0 |
|
- |
4.1.6.2(Elongation at break after ageing ) |
- |
18000 |
|
- |
4.1.6.2(Tensile after ageing ) |
- |
18000 |
|
- |
4.1.6(Compression set ) |
- |
18000 |
|
- |
4.1.6(Elongation at break ) |
- |
18000 |
|
- |
4.1.6(Tensile strength) |
- |
18000 |
|
- |
4.1.6(Hardness (after accelerated )) |
- |
18000 |
|
- |
4.1.6(Flexing resistance test) |
- |
0 |
|
- |
4.1.6(Hardness ) |
- |
0 |
|
- |
4.1.6(Relative density) |
- |
18000 |
|
- |
4.1.5(Sulpher dyes content ) |
- |
18000 |
|
- |
4.1.5(Breaking Load ) |
- |
18000 |
|
- |
4.1.5(Length ) |
- |
18000 |
|
- |
4.1.4(Thickness) |
- |
18000 |
|
- |
4.1.4(Size ) |
- |
18000 |
|
- |
4.1.3(Color fastness to perspiration) |
- |
18000 |
|
- |
4.1.3(Colorfastness to washing) |
- |
18000 |
|
- |
4.1.3(Colorfastness to light ) |
- |
18000 |
|
- |
4.1.3(Single thread breaking load) |
- |
18000 |
|
- |
4.1.3(Construction ) |
- |
0 |
|
- |
4.1.2(Colorfastness to light ) |
- |
0 |
|
- |
4.1.2(Colorfastness to washing) |
- |
0 |
|
- |
4.1.2(Breaking Strength ) |
- |
0 |
|
- |
4.1.2(Width ) |
- |
0 |
|
- |
4.1.1.2(Colorfastness to washing) |
- |
0 |
|
- |
4.1.1.1(Colorfastness to light ) |
- |
0 |
|
- |
4.1.1 (Drill) (End & Picks/dm) |
- |
18000 |
|
- |
4.1.1 (Drill) (Colorfastness to light ) |
- |
18000 |
|
- |
4.1.1 (canvas )(End & Picks/dm) |
- |
18000 |
|
- |
4.1.1 (canvas )(Breaking Load ) |
- |
18000 |
|
- |
5, 5.1, Cl. 5.2, Cl. 5.2.1, Cl. 5.2.1.1(Packing and marking) |
- |
18000 |
|
- |
" CL. 5.1, Cl. 5.2, Cl. 5.2.1, Cl. 5.2.1.1(Packing and marking ") |
- |
0 |
|
- |
|
25 Feb, 2027 |
- Amendment No. 5 included w.e.f. 25.03.2025 |
5 |
IS 2266 (2024) |
STEEL WIRE ROPES FOR GENERAL ENGINEERING PURPOSE - SPECIFICATION (Sixth Revision) |
- |
19900 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Cl-5(Minimum breaking force) |
- |
0 |
|
- |
Cl-6(Wire rope) |
- |
0 |
|
- |
Cl-7(Construction) |
- |
0 |
|
- |
Cl-8.1(Fibre Core) |
- |
0 |
|
- |
Cl-8.2(Steel Core) |
- |
0 |
|
- |
Cl-9(Joints) |
- |
0 |
|
- |
Cl-10(Galvanizing) |
- |
0 |
|
- |
Cl-12(Marking) |
- |
0 |
|
- |
Cl-4(Rope size and Tolerance) |
- |
0 |
|
- |
Cl-5(Minimum breaking force) |
- |
0 |
|
- |
Cl-6(Wire rope) |
- |
0 |
|
- |
Cl-7(Construction) |
- |
0 |
|
- |
Cl-8.1(Fibre Core) |
- |
0 |
|
- |
Cl-8.2(Steel Core) |
- |
0 |
|
- |
Cl-9(Joints) |
- |
0 |
|
- |
Cl-10(Galvanizing) |
- |
0 |
|
- |
Cl-12(Marking) |
- |
0 |
|
- |
Cl-4(Rope size and Tolerance) |
- |
0 |
|
- |
Cl-5(Minimum breaking force) |
- |
0 |
|
- |
Cl-6(Wire rope) |
- |
0 |
|
- |
Cl-7(Construction) |
- |
0 |
|
- |
Cl-8.1(Fibre Core) |
- |
0 |
|
- |
Cl-8.2(Steel Core) |
- |
0 |
|
- |
Cl-9(Joints) |
- |
0 |
|
- |
Cl-10(Galvanizing) |
- |
0 |
|
- |
Cl-12(Marking) |
- |
0 |
|
- |
Cl-4(Rope size and Tolerance) |
- |
0 |
|
- |
|
25 Feb, 2027 |
- Included w.e.f 09.04.2025 |
6 |
IS 4521 (2024) |
Wire Ropes Used in Oil Wells and Oil Well Drilling and Other Applications of Petroleum and Natural Gas Industries - Specification (Third Revision) |
- |
19900 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Cl-4(Size, Construction, Core and Grades) |
- |
0 |
|
- |
Cl-5(Minimum breaking force) |
- |
0 |
|
- |
Cl-6.1(Wire for guy strands) |
- |
0 |
|
- |
Cl-6.2(Core) |
- |
0 |
|
- |
Cl-6.3(Joints) |
- |
0 |
|
- |
Cl-6.4(Mass) |
- |
0 |
|
- |
Cl-6.5(Lay of the Rope) |
- |
0 |
|
- |
Cl-6.6(Length of Lay) |
- |
0 |
|
- |
Cl-7(Galvanizing) |
- |
0 |
|
- |
Cl-8(Lubrication) |
- |
0 |
|
- |
Cl-9(Rope grades) |
- |
0 |
|
- |
Cl-10(wire tensile strength grade) |
- |
0 |
|
- |
Cl-11(Tolerance in rope diameter) |
- |
0 |
|
- |
Cl-12(Marking) |
- |
0 |
|
- |
Cl-4(Size, Construction, Core and Grades) |
- |
0 |
|
- |
Cl-5(Minimum breaking force) |
- |
0 |
|
- |
Cl-6.1(Wire for guy strands) |
- |
0 |
|
- |
Cl-6.2(Core) |
- |
0 |
|
- |
Cl-6.3(Joints) |
- |
0 |
|
- |
Cl-6.4(Mass) |
- |
0 |
|
- |
Cl-6.5(Lay of the Rope) |
- |
0 |
|
- |
Cl-6.6(Length of Lay) |
- |
0 |
|
- |
Cl-7(Galvanizing) |
- |
0 |
|
- |
Cl-8(Lubrication) |
- |
0 |
|
- |
Cl-9(Rope grades) |
- |
0 |
|
- |
Cl-10(wire tensile strength grade) |
- |
0 |
|
- |
Cl-11(Tolerance in rope diameter) |
- |
0 |
|
- |
Cl-12(Marking) |
- |
0 |
|
- |
Cl-4(Size, Construction, Core and Grades) |
- |
0 |
|
- |
Cl-5(Minimum breaking force) |
- |
0 |
|
- |
Cl-6.1(Wire for guy strands) |
- |
0 |
|
- |
Cl-6.2(Core) |
- |
0 |
|
- |
Cl-6.3(Joints) |
- |
0 |
|
- |
Cl-6.4(Mass) |
- |
0 |
|
- |
Cl-6.5(Lay of the Rope) |
- |
0 |
|
- |
Cl-6.6(Length of Lay) |
- |
0 |
|
- |
Cl-7(Galvanizing) |
- |
0 |
|
- |
Cl-8(Lubrication) |
- |
0 |
|
- |
Cl-9(Rope grades) |
- |
0 |
|
- |
Cl-10(wire tensile strength grade) |
- |
0 |
|
- |
Cl-11(Tolerance in rope diameter) |
- |
0 |
|
- |
Cl-12(Marking) |
- |
0 |
|
- |
|
25 Feb, 2027 |
- Included w.e.f 09.04.2025 |
7 |
IS 18427 (2024) |
Three piece round open top metal cans for foods and beverages -- Specification |
- |
34900 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Cl-5.1.1(C) |
- |
0 |
|
- |
Cl-5.1.1(Si) |
- |
0 |
|
- |
Cl-5.1.1(Mn) |
- |
0 |
|
- |
Cl-5.1.1(P) |
- |
0 |
|
- |
Cl-5.1.1(S) |
- |
0 |
|
- |
Cl-5.1.2, Table-1("Tinplate Nominal Thickness- Flattened
Body") |
- |
0 |
|
- |
Cl-5.1.2, Table-1(Built-up Can Body- Beaded) |
- |
0 |
|
- |
Cl-5.1.2, Table-1(Built-up Can Body- Un-beaded) |
- |
0 |
|
- |
Cl-5.1.2, Table-1(Tinplate Nominal Thickness- NEO Ends) |
- |
0 |
|
- |
Cl-5.1.2, Table-2(Tinplate Nominal Thickness- Un-beaded Body) |
- |
0 |
|
- |
Cl-5.1.2, Table-2(Tinplate Nominal Thickness- Beaded Body) |
- |
0 |
|
- |
Cl-5.1.2, Table-2(Tinplate Nominal Thickness- NEO End) |
- |
0 |
|
- |
Cl-5.1.2, Table-2(Tinplate Nominal Thickness- Ring) |
- |
0 |
|
- |
Cl-5.1.2, Table-2(Tinplate Nominal Thickness- Lid) |
- |
0 |
|
- |
Cl-5.1.3, Table-3 (i)(Mango pulp – Body and ends) |
- |
0 |
|
- |
Cl-5.1.3, Table-3 (ii)(Pineapple – Body and ends) |
- |
0 |
|
- |
Cl-5.1.3, Table-3 (iii)(All other thermally processed cans – Body and ends) |
- |
0 |
|
- |
Cl-5.1.3, Table-3 (iv)(Non-thermally processed can – Body and ends) |
- |
0 |
|
- |
Cl-5.1.3, Table-3 (v)(Ring and lid) |
- |
0 |
|
- |
Cl-5.1.3, Table-3 (vi)(POE ring) |
- |
0 |
|
- |
Cl-5.1.4(Surface Finish) |
- |
0 |
|
- |
Cl-5.1.5(Tin Grain Size) |
- |
0 |
|
- |
Cl-5.1.6(Iron Solution Value) |
- |
0 |
|
- |
Cl-5.1.7(Surface Oil) |
- |
0 |
|
- |
Cl-5.1.8(Passivation Treatment) |
- |
0 |
|
- |
Cl-5.1.9(Edge Camber and Out-of-Squareness) |
- |
0 |
|
- |
Cl-5.1.10(Mechanical Properties) |
- |
0 |
|
- |
Cl-5.2(Lacquers and Decorative Coatings) |
- |
0 |
|
- |
Cl-5.3(Inks) |
- |
0 |
|
- |
Cl-5.4(Lining Compound/Can End Sealants) |
- |
0 |
|
- |
Cl-5.5(Side Stripe Systems) |
- |
0 |
|
- |
Cl-5.6(Easy Open End) |
- |
0 |
|
- |
Cl-5.7(Aluminium Tagger) |
- |
0 |
|
- |
Cl-5.8(Peel Off Ends (POE)) |
- |
0 |
|
- |
Cl-5.9(Surface Lubrications and Rust Prevention Oils) |
- |
0 |
|
- |
Cl-6.1, Table-5(Internal Diameter) |
- |
0 |
|
- |
Cl-6.1, Table-5(Necked-In Side Trade Size) |
- |
0 |
|
- |
Cl-6.1, Table-5(Necked-In Side Nominal Diameter) |
- |
0 |
|
- |
Cl-6.2(Capacities) |
- |
0 |
|
- |
Cl-7(Manufacture) |
- |
0 |
|
- |
Cl-8.1, Table-9 (i)(Thermally processed food cans) |
- |
0 |
|
- |
Cl-8.1, Table-9 (ii)(Nonthermally processed food cans) |
- |
0 |
|
- |
Cl-8.2(Vacuum Test) |
- |
0 |
|
- |
Cl-8.3(Migration Test) |
- |
0 |
|
- |
Cl-8.4(Specific Migration Limit (SML) |
- |
0 |
|
- |
Cl-10.1(Marking) |
- |
0 |
|
- |
|
25 Feb, 2027 |
- Included w.e.f 16.04.2025 |
8 |
IS 17514 (2021) |
Reusable Sanitary PadSanitary Napkin Period panties Specification |
- |
15900 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
3.1(Material- Cover/Top sheet) |
- |
0 |
|
- |
3.2(Material- Absorbent Core) |
- |
0 |
|
- |
3.3(Material- Bottom Layer) |
- |
0 |
|
- |
4.0(Manufacturing , workmanship and finish) |
- |
0 |
|
- |
5.0(Fastening Mechanism) |
- |
0 |
|
- |
6.0(Sizes:- Pad Length and Pad Width (For Absorbent core only)) |
- |
0 |
|
- |
7.0(Washing , Drying And Handling Instruction) |
- |
0 |
|
- |
8 & 11.2.4, Table 1, (i)(Colour Fastness to Rubbing) |
- |
0 |
|
- |
Cl-9.5(Phthalate Test) |
- |
0 |
|
- |
8 & 11.2.4, Table 1, (ii)(Colour Fastness to Perspiration (Acidic & Alkaline)) |
- |
0 |
|
- |
8 & 11.2.4, Table 1, (iii)(Colour Fastness to Washing) |
- |
0 |
|
- |
8 & 11.2.4, Table 1, (iv)(Dimensional Stability to washing, percentage) |
- |
0 |
|
- |
9.1(pH Value) |
- |
0 |
|
- |
9.2(Ability to Withstand Pressure after Absorption) |
- |
0 |
|
- |
9.3.1(Bacterial and Fungal Bioburden) |
- |
0 |
|
- |
9.3.2(Test for Common Skin Pathogen -Staphylococcus Aureus) |
- |
0 |
|
- |
12.0(Marking & Packing) |
- |
0 |
|
- |
13.0(Marking & Packing) |
- |
0 |
|
- |
Clause No. 6(Pad length and width) |
- |
0 |
|
- |
Clause No. 8, Table No. 1, (i)(Colour fastness to rubbing of fabric) |
- |
0 |
|
- |
Clause No. 8, Table No. 1, (ii)(Colour fastness to perspiration (acidic and alkaline)) |
- |
0 |
|
- |
Clause No. 8, Table No. 1, (iii)(Colour fastness to washing) |
- |
0 |
|
- |
Clause No. 8, Table No. 1, (iv)(Dimensional stability to washing, length and width) |
- |
0 |
|
- |
Clause No. 9.1(pH Value) |
- |
0 |
|
- |
Clause No. 9.2(Ability to Withstand Pressure after Absorption) |
- |
0 |
|
- |
Clause No. 9.3(Hygiene Testing Requirement) |
- |
0 |
|
- |
Clause No. 9.3.1(Bacterial and Fungal Bioburden) |
- |
0 |
|
- |
Clause No. 9.3.2(Test for Common Skin Pathogen — Staphylococcus Aureus) |
- |
0 |
|
- |
Clause No. 9.4(Biocompatibility Evaluation — Cytotoxicity, Irritation and Skin Sensitization) |
- |
0 |
|
- |
Clasue No. 10(Anti-Bacterial Activity Value) |
- |
0 |
|
- |
9.1(pH of Aqueous extract) |
- |
0 |
|
- |
9.5(Phthalate Test: Di-n-butyl phthalate (DBP)) |
- |
0 |
|
- |
9.5(Phthalate Test: Benzyl butyl phthalate (BBP)) |
- |
0 |
|
- |
9.5(Phthalate Test: Bis- (2-ethylhexyl) phthalate (DEHP)) |
- |
0 |
|
- |
9.5(Phthalate Test: di-n-octyl phtahlate (DNOP)) |
- |
0 |
|
- |
9.5(Phthalate Test: Di-iso-nonyl phthalate (DINP)) |
- |
0 |
|
- |
9.5(Phthalate Test: Di-iso-decyl phthalate (DIDP)) |
- |
0 |
|
- |
|
25 Feb, 2027 |
- Included w.e.f 04.06.2025 |
9 |
IS 17509 (2021) |
Disposable Baby Diaper Specification |
- |
21000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Clause no. 3(Material) |
- |
0 |
|
- |
Clause no. 3.1(Top Cover / Top Sheet) |
- |
0 |
|
- |
Clause no. 3.2(Absorbent Core) |
- |
0 |
|
- |
Clause no. 3.3(Outer Protective Barrier or Back Sheet) |
- |
0 |
|
- |
Clause no. 4(Fastening & Securing Mechanism) |
- |
0 |
|
- |
Clause no. 5(ManufactureWorkmanship and Finish) |
- |
0 |
|
- |
Clause no.6(Type and Size: FOR X LARGE) |
- |
0 |
|
- |
Clause no.6(Diaper Length) |
- |
0 |
|
- |
Clause no.6(Diaper Width) |
- |
0 |
|
- |
Clause no.6(Diaper Crotch) |
- |
0 |
|
- |
Clause no.6(Absorbent Core Length) |
- |
0 |
|
- |
Clause no.6(Absorbent Core Width Back) |
- |
0 |
|
- |
1() |
- |
0 |
|
- |
Clause no.6(Absorbent Core Length) |
- |
0 |
|
- |
Clause no.6(Absorbent Core Width Front) |
- |
0 |
|
- |
Clause no.6(Core Cortch) |
- |
0 |
|
- |
Clause no.7(Performance Requirements) |
- |
0 |
|
- |
Clause no.7.1(pH Value) |
- |
0 |
|
- |
Clause no.7.2 Table-2(Minimum absorption Capacity (X Large)) |
- |
0 |
|
- |
Clause no.7.2 Table-2(Rewet under Load (All Sizes)) |
- |
0 |
|
- |
Clause no.7.2 Table-2(Rate of Absorption (All Sizes)) |
- |
0 |
|
- |
Clause no.7.3(Hygiene Testing Requirement, Total Viable Count) |
- |
0 |
|
- |
Clause no.7.3(Hygiene Testing Requirement, Staphylococcus Aureus) |
- |
0 |
|
- |
Clause no.7.4(Biocompatibility Evaluation- Cytotoxicity) |
- |
0 |
|
- |
Clause no. 7.4(Biocompatibility Evaluation- Irritation) |
- |
0 |
|
- |
Clause no.7.4(Biocompatibility Evaluation- Skin Sensitization) |
- |
0 |
|
- |
Clause no.7.5(Phthalate Test) |
- |
0 |
|
- |
Clause no.7.6(Biodegradability and Compostability (optional)) |
- |
0 |
|
- |
Clause no.7.7(Anti-Bacterial Activity Value (optional)) |
- |
0 |
|
- |
9 & 9.1(Marking) |
- |
0 |
|
- |
10(Packing) |
- |
0 |
|
- |
CL 7.3(Total Viable Count) |
- |
0 |
|
- |
CL 7.3(Staphylococcus aureus) |
- |
0 |
|
- |
CL 7.4(Biocompatibility Evaluation - Cytotoxicity, Irritation and Skin Sensitization) |
- |
0 |
|
- |
CL 7.6(Biodegradability and Compostability (Optional)) |
- |
0 |
|
- |
CL 7.7(Anti-Bacterial Activity Value (Optional)) |
- |
0 |
|
- |
6.2(Type and Sizes) |
- |
0 |
|
- |
|
25 Feb, 2027 |
- Included w.e.f 04.06.2025 |
10 |
IS 5405 (2019) |
Sanitary napkins – Specification (second revision) |
- |
15900 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Cl 5(SIZES, Regular ) |
- |
0 |
|
- |
Cl 5(SIZES, Large) |
- |
0 |
|
- |
Cl 5(SIZES, Extra Large) |
- |
0 |
|
- |
Cl 5(SIZES, XXL) |
- |
0 |
|
- |
Cl 5(Absorbent Capacity, Regular ) |
- |
0 |
|
- |
Cl 5(Absorbent Capacity, Large) |
- |
0 |
|
- |
Cl 5(Absorbent Capacity, Extra Large) |
- |
0 |
|
- |
Cl 5(Absorbent Capacity, XXL) |
- |
0 |
|
- |
Cl 7.1(pH Value, IS 1390 (cold method) for all sizes) |
- |
0 |
|
- |
Cl 7.2(Ability to Withstand Pressure after Absorption, for all sizes, Annex B) |
- |
0 |
|
- |
Cl 7.3.1(Bacterial and Fungal Bioburden, 7.3.1.1, ISO 11737 (Part 1)) |
- |
0 |
|
- |
Cl7.3.2(Test for Common Skin Pathogen — Staphylococcus
Aureus, 7.3.2.1, IS 5887 (Part 2)) |
- |
0 |
|
- |
Cl 7.4(Biocompatibility Evaluation — Cytotoxicity,
Irritation and Skin Sensitization, IS/ISO 10993 Part 5
and IS/ISO 10993 Part 10) |
- |
0 |
|
- |
Cl 7.5(Biodegradability and Compostability
(Optional), IS/ISO 17088.) |
- |
0 |
|
- |
Cl 5(SIZES, Regular ) |
- |
0 |
|
- |
Cl 5(SIZES, Large) |
- |
0 |
|
- |
Cl 5(SIZES, Extra Large) |
- |
0 |
|
- |
Cl 5(SIZES, XXL) |
- |
0 |
|
- |
Cl 5(Absorbent Capacity, Regular ) |
- |
0 |
|
- |
Cl 5(Absorbent Capacity, Large) |
- |
0 |
|
- |
Cl 5(Absorbent Capacity, Extra Large) |
- |
0 |
|
- |
Cl 5(Absorbent Capacity, XXL) |
- |
0 |
|
- |
Cl 7.1(pH Value, IS 1390 (cold method) for all sizes) |
- |
0 |
|
- |
Cl 7.2(Ability to Withstand Pressure after Absorption, for all sizes, Annex B) |
- |
0 |
|
- |
Cl 7.3.1(Bacterial and Fungal Bioburden, 7.3.1.1, ISO 11737 (Part 1)) |
- |
0 |
|
- |
Cl7.3.2(Test for Common Skin Pathogen — Staphylococcus
Aureus, 7.3.2.1, IS 5887 (Part 2)) |
- |
0 |
|
- |
Cl 7.4(Biocompatibility Evaluation — Cytotoxicity,
Irritation and Skin Sensitization, IS/ISO 10993 Part 5
and IS/ISO 10993 Part 10) |
- |
0 |
|
- |
Cl 7.5(Biodegradability and Compostability
(Optional), IS/ISO 17088.) |
- |
0 |
|
- |
3.1(Cover/Top sheet) |
- |
0 |
|
- |
3.2(Absorbent Core) |
- |
0 |
|
- |
3.3(Barrier or Bottom Sheet) |
- |
0 |
|
- |
4.1 (1)(Type and shapes of sanitary napkins) |
- |
0 |
|
- |
4.2(Sanitary napkins shape & design) |
- |
0 |
|
- |
6.0(Manufacture, workmanship & finish) |
- |
0 |
|
- |
CL 7.4(Biocompatibility Evaluation - Cytotoxicity, Irritation and Skin Sensitization (Optional)) |
- |
0 |
|
- |
CL 7.5(Compostability or Biodegradability during Composting (Optional)) |
- |
0 |
|
- |
7.6(Pthalate test) |
- |
0 |
|
- |
|
25 Feb, 2027 |
- Included w.e.f 04.06.2025 |
11 |
IS 15844 : Part 3 (2024) |
Sports Footwear Part 3 Professional Sports Footwear |
- |
64900 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Cl-6(Size and Fittings) |
- |
1000 |
|
- |
Cl-5(Design) |
- |
1000 |
|
- |
Cl-6(Size and Fittings) |
- |
1000 |
|
- |
Cl.7.1.1(Upper to Mid Sole/Out Sole, Upper to Composite Sole (Applicable Only When the Sole is Composite) and Out Sole to Mid Sole (Multilayer, if Present), Bond Performance) |
- |
6000 |
|
Upper to midsole/outsole-Rs 2000/-
Upper to composite sole- Rs 2000/-
Outsole to midsole-Rs 2000/- |
Cl.7.1.2(Energy Absorption at Seat Region) |
- |
2000 |
|
- |
Cl.7.1.1(Upper to Mid Sole/Out Sole, Upper to Composite Sole (Applicable Only When the Sole is Composite) and Out Sole to Mid Sole (Multilayer, if Present), Bond Performance) |
- |
0 |
|
- |
Cl.7.1.2(Energy Absorption at Seat Region) |
- |
0 |
|
- |
Cl.7.1.3(Complete Shoe Flexing) |
- |
4000 |
|
- |
Cl.7.1.4(Washability) |
- |
5500 |
|
- |
Cl.7.1.5(Slip Resistance) |
- |
5500 |
|
- |
Cl.7.1.6(Heel Drop) |
- |
1000 |
|
- |
Cl.7.2 Table-2 S.No- (i)("Flexing resistance, Min
a) Dry condition
b) Wet condition") |
- |
2000 |
|
Dry condition- Rs 1000/-
Wet condition- Rs 1000/- |
Cl.7.2 Table-2 S.No- (ii)(Tear strength (average force), N, Min) |
- |
1000 |
|
- |
Cl.7.2 Table-2 S.No- (iii)("Colour fastness rubbing
a-Dry
b-Wet") |
- |
3000 |
|
Dry- Rs 1500/-
Wet- Rs 1500/- |
Cl.7.2 Table-2 S.No- (iv)("a) Water vapour permeability
b) Water vapour coefficient") |
- |
2000 |
|
water vapour permeability- Rs 1000/-
Water vapour coefficient- Rs 1000/- |
Cl.7.2 Table-2 S.No- (v)(Stitch tear strength N/mm, Min) |
- |
1000 |
|
- |
Cl.7.2 Table-2 S.No- (vi)(Colour fastness to light grey scale rate) |
- |
5000 |
|
- |
Cl.7.2 Table-2 S.No- (vii)(Tensile strength) |
- |
1000 |
|
- |
Cl.7.2 Table-2 S.No- (viii)(Elongation at break, percent) |
- |
1000 |
|
- |
Cl.7.2 Table-2 S.No- (ix)("Abrasion test
a) Dry
b) Wet") |
- |
3000 |
|
Dry- Rs 1500/-
Wet- Rs 1500/- |
Cl.7.2 Table-3 S.No- (i)(Breaking strength, N/mm, Min) |
- |
1000 |
|
- |
Cl.7.2 Table-3 S.No- (ii)(Elongation at break, percent, Min) |
- |
1000 |
|
- |
Cl.7.2 Table-3 S.No- (iii)(Tear strength, N, Min) |
- |
1000 |
|
- |
Cl.7.2 Table-3 S.No- (iv)(Strength at needle perforation) |
- |
1000 |
|
- |
Cl.7.2 Table-3 S.No- (v)("Flexing resistance
a-Dry condition, b) Wet condition") |
- |
3000 |
|
Dry- Rs 1500/-
Wet- Rs 1500/- |
Cl.7.2 Table-3 S.No- (vi)("a) Water vapour permeability
b) Water vapour coefficient") |
- |
2000 |
|
water vapour permeability- Rs 1000/-
Water vapour coefficient- Rs 1000/- |
Cl.7.2 Table-3 S.No- (vii)(Hydrolysis resistance) |
- |
1500 |
|
- |
Cl.7.2 Table-3 S.No- (viii)(Colour fastness to light grey scale rate) |
- |
5000 |
|
- |
Cl.7.2 Table-3 S.No- (ix)(Bursting strength) |
- |
1000 |
|
- |
Cl.7.3 Table-4 S.No- (i)(Tear strength, N, Min) |
- |
1000 |
|
- |
Cl.7.3 Table-4 S.No- (ii)("Abrasion resistance,
a) Dry
b) Wet
") |
- |
3000 |
|
Dry- Rs 1500/-
Wet- Rs 1500/- |
Cl.7.3 Table-4 S.No- (iii)(Colour fastness to rubbing, grey scale rate with 10 rubs on dry or wet, Min) |
- |
1000 |
|
- |
Cl.7.3 Table-4 S.No- (iv)(Colour fastness to perspiration (contact method) grey scale rate, Min) |
- |
1000 |
|
- |
Cl.7.3 Table-4 S.No- (v)("a-Water vapour permeability
b-Water vapour coefficient") |
- |
2000 |
|
water vapour permeability- Rs 1000/-
Water vapour coefficient- Rs 1000/- |
Cl.7.4 Table-5 S.No- (i)(Flexing index, Min) |
- |
1000 |
|
- |
Cl.7.4 Table-5 S.No- (ii)(Abrasion resistance) |
- |
1500 |
|
- |
Cl.7.4 Table-5 S.No- (iii)("a) Water absorption
b) Water desorption") |
- |
3000 |
|
Water absorption- Rs 1500/-
Water desorption- Rs 1500/- |
Cl.7.5 Table-6 S.No- (i)("Abrasion resistance
a) Dry condition
b) Wet condition") |
- |
3000 |
|
Dry- Rs 1500/-
Wet- Rs 1500/- |
Cl.7.5 Table-6 S.No- (ii)("a) Water absorption
b) Water desorption") |
- |
3000 |
|
Water absorption- Rs 1500/-
Water desorption- Rs 1500/- |
Cl.7.5 Table-6 S.No- (iii)(Heat resistance shrinkage linear, percent, Max) |
- |
1000 |
|
- |
Cl.7.6 Table-7 S.No- (i)(Abrasion resistance) |
- |
1000 |
|
- |
Cl.7.6 Table-7 S.No- (ii)("Flexing resistance
a) Bennewart Method
b) Ross flexing method") |
- |
1500 |
|
- |
Cl.7.6 Table-7 S.No- (iii)(Hydrolysis resistance) |
- |
1500 |
|
- |
Cl.7.6 Table-7 S.No- (iv)(Tear strength, N/mm, Min) |
- |
1000 |
|
Complete Testing Charges |
Cl.7.6 Table-7 S.No- (v)(Tensile strength) |
- |
1000 |
|
- |
Cl.7.6 Table-7 S.No- (vi)(Elongation at break percent, Min) |
- |
1000 |
|
- |
Cl.7.6 Table-7 S.No- (vii)(Compression set percent, Max) |
- |
1000 |
|
- |
Cl.7.7 Table-8 S.No- (i)("Compression set, percent, Max
a) For EVA
b) For all other material") |
- |
1000 |
|
- |
Cl.7.7 Table-8 S.No- (ii)(Split tear strength) |
- |
1000 |
|
- |
Cl.7.7 Table-8 S.No- (iii)(Heat shrinkage, percent, Ma) |
- |
1000 |
|
- |
Cl.7.7 Table-8 S.No- (iii)(Elongation at break, percent, Min) |
- |
1000 |
|
- |
Cl.7.7 Table-8 S.No- (iv)(Elongation at break, percent, Min) |
- |
1000 |
|
- |
Cl.7.8 Table-9 S.No- (i)(First dry collapsing load, hardness, N, Min) |
- |
0 |
|
Cl 7.8 Table 9, S.no.1 to S.no. 4- Total Rs 2500/- |
Cl.7.8 Table-9 S.No- (ii)(Resilience, percent, Min) |
- |
0 |
|
- |
Cl.7.8 Table-9 S.No- (iii)(Moisture resistance, percent, Min) |
- |
0 |
|
- |
Cl.7.8 Table-9 S.No- (iv)("a) Initial dry area shape retention, percent, Min
b) Area shape retention after 10th
collapse, dry, percent, Min
") |
- |
0 |
|
- |
Cl.7.8 Table-9 S.No- (v)(Peel strength, N/nm, Min) |
- |
1000 |
|
- |
Cl.7.9 Table-10 S.No- (i)("Peel strength, N/mm, Min
a) Initial
b) After 5 000 wear cycles") |
- |
3000 |
|
Peel strength, initial- Rs 1500/-
Peel strength, After 5000 cycle- Rs 1500/- |
Cl.7.9 Table-10 S.No- (ii)("Shear strength, kPa, Min
a) Initial
b) After 5 000 wear cycles") |
- |
3000 |
|
shear strength, initial- Rs 1500/-
shear strength, After 5000 cycle- Rs 1500/- |
Cl.7.10 Table-11 S.No- (i)(Limit of useful extension, percent, Min) |
- |
1000 |
|
- |
Cl.7.10 Table-11 S.No- (ii)(Needle strength, N/mm, Min) |
- |
1000 |
|
- |
Cl.7.11 Table-12 S.No- (i)(Breaking strength of lace) |
- |
1000 |
|
- |
Cl.7.11 Table-12 S.No- (ii)(Lace tag strength) |
- |
1000 |
|
- |
Cl.7.11 Table-12 S.No- (iii)(Lace to lace abrasion) |
- |
1000 |
|
- |
Cl.7.11 Table-12 S.No- (iv)(Colour fastness to water (for lace) (Contact method)) |
- |
1000 |
|
- |
Cl.7.11 Table-12 S.No- (v)(Strength of buckle/ski hook/D-ring,) |
- |
1000 |
|
- |
Cl.7.11 Table-12 S.No- (vi)("Corrosion resistance (applicable for all including decorative metal part)
") |
- |
1000 |
|
- |
Cl.7.11 Table-13 S.No- (i)(Corrosion resistance (applicable for metallic spikes)) |
- |
1000 |
|
- |
Cl-7.12.1, Table no. 1 of IS 17011,(i)(Allergenic and carcinogenic disperse dyes) |
- |
0 |
|
Chemical requirement- Rs 35000/-, Lead content- Rs 2500/- |
Cl-7.12.1, Table no. 1 of IS 17011,(ii)(Aromatic amines released from Azo dyes (each individual amine)) |
- |
0 |
|
- |
Cl-7.12.1, Table no. 1 of IS 17011,(iii)(Aromatic amines released from Azo dyes (each individual amine)) |
- |
0 |
|
- |
Cl-7.12.1, Table no. 1 of IS 17011,(iv)(Chromium (VI)) |
- |
0 |
|
- |
Cl-7.12.1, Table no. 1 of IS 17011,(v)(Dimethyl fumarate (DMFU)) |
- |
0 |
|
- |
Cl-7.12.1, Table no. 1 of IS 17011,(vi)(Formaldehyde (free or released by partial hydrolysis)) |
- |
0 |
|
- |
Cl-7.12.1, Table no. 1 of IS 17011,(vii)(Formaldehyde) |
- |
0 |
|
- |
Cl-7.12.1, Table no. 1 of IS 17011,(viii)(Organotin compounds) |
- |
0 |
|
- |
Cl-7.12.1, Table no. 1 of IS 17011,(ix)(PCP-TeCP-TriCP polychlorophenols) |
- |
0 |
|
- |
Cl-7.12.1, Table no. 1 of IS 17011,(viii)(Organotin compounds) |
- |
0 |
|
- |
Cl-7.12.1, Table no. 1 of IS 17011,(vi)(Formaldehyde (free or released by partial hydrolysis)) |
- |
0 |
|
- |
Cl-7.12.1, Table no. 1 of IS 17011,(v)(Dimethyl fumarate (DMFU)) |
- |
0 |
|
- |
Cl-7.12.1, Table no. 1 of IS 17011,(iv)(Chromium (VI)) |
- |
0 |
|
- |
Cl-7.12.1, Table no. 1 of IS 17011,(x)(pH) |
- |
0 |
|
- |
Cl-7.12.1, Table no. 1 of IS 17011,(xi)(Phthalates (each individual phthalate)) |
- |
0 |
|
- |
C-7.12.1, Table no. 1 of IS 17011,(xii)(Nickel, on skin contact 2-(thiocyanomethylthio) -benzothiazole (TCMTB)) |
- |
0 |
|
- |
Cl-7.12.2(PVC is present in sports shoe) |
- |
0 |
|
- |
Cl- 8.1(Marking) |
- |
500 |
|
- |
|
25 Feb, 2027 |
- - |
12 |
IS 15844 : Part 2 (2023) |
SPORTS FOOTWEAR PART -2 PERFORMANCE SPORTS FOOTWEAR |
all |
64900 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
4(SAMPLING AND CONDITIONING) |
- |
1000 |
|
- |
5(DESIGN) |
- |
1000 |
|
- |
6(SIZE AND FITTINGS) |
- |
1000 |
|
- |
7.1.1(Whole Footwear) |
- |
1000 |
|
- |
7.1.2(Upper to Mid Sole/Out Sole Bond Performance) |
- |
2000 |
|
- |
7.1.3("Upper to Composite Sole Bond Performance
(Applicable Only When the Sole is Composite)") |
- |
2000 |
|
- |
7.1.4(Out Sole to Mid Sole (Multilayer) Bond Performance) |
- |
2000 |
|
- |
7.1.5(Energy Absorption at Seat Region) |
- |
2000 |
|
- |
7.1.6(Complete Shoe Flexing) |
- |
4000 |
|
- |
7.1.7(Washability) |
- |
5500 |
|
- |
7.1.8(Slip Resistance) |
- |
5500 |
|
- |
7.1.9(Heel Drop) |
- |
1000 |
|
- |
7.2 , Table No. 2 , i)(Flexing resistance) |
- |
1500 |
|
- |
7.2 , Table No. 2 , ii)(Tear strength (average force)) |
- |
1000 |
|
- |
7.2 , Table No. 2 , iii)("Colour fastness rubbing (To and fro) Grey scale rate
Dry: (rubbing) Rating: (Marring and staining) ") |
- |
1500 |
|
- |
7.2 , Table No. 2 , iv) ,a)(Water vapour permeability) |
- |
1000 |
|
- |
7.2 , Table No. 2 , iv) ,b)(Water vapour coefficient) |
- |
1000 |
|
- |
7.2 , Table No. 2 , v)(Stitch tear strength (double hole)) |
- |
1000 |
|
- |
7.2 , Table No. 2 , vi)("Colour fastness to light (Optional) Grey scale rate,
Rating: (Marring)") |
- |
5000 |
|
- |
7.2 , Table No. 2 , vii)(Tensile strength) |
- |
1000 |
|
- |
7.2 , Table No. 2 , viii)(Elongation at break,) |
- |
1000 |
|
- |
7.2 , Table No. 2 , ix)("Water penetration and water absorption after 60 Minutes
Water absorption %, Max Water penetration Gms, Max") |
- |
1000 |
|
- |
7.2 , Table No. 2 , x)(Abrasion test (for unlined upper)) |
- |
1500 |
|
- |
7.2 , Table No. 3 , i)(Breaking strength
"As per Method 1 of IS 7016 (Part 2)/
ISO 1421 : 2016 or ISO 17706") |
- |
1000 |
|
- |
7.2 , Table No. 3 , ii)(Elongation at break) |
- |
1000 |
|
- |
7.2 , Table No. 3 , iii)(Tear strength, N, Min For Fabric: For all other materials) |
- |
1000 |
|
- |
7.2 , Table No. 3 , iv)(Strength at needle perforation) |
- |
1000 |
|
- |
7.2 , Table No. 3 , v)("Flexing resistance, no crack/damage to coating/ lamination
/ upper material till prescribed cycles") |
- |
1500 |
|
- |
7.2 , Table No. 3 , vi) , a)(Water vapour permeability,) |
- |
1000 |
|
- |
7.2 , Table No. 3 , vi) , b)("Water vapour coefficient,
") |
- |
1000 |
|
- |
7.2 , Table No. 3 , vii)(Hydrolysis resistance) |
- |
1500 |
|
- |
7.2 , Table No. 3 , viii)(Colour fastness to light grey scale rate) |
- |
5000 |
|
- |
7.2 , Table No. 3 , ix)(Bursting Strength,) |
- |
1000 |
|
- |
7.3 , Table No. 4 , i)(Tear strength,) |
- |
1000 |
|
- |
7.3 , Table No. 4 , ii)(Abrasion resistance, cycles) |
- |
1500 |
|
- |
7.3 , Table No. 4 , iii)("Colour fastness to rubbing (crocking), Grey scale
rate with 10 rubs on dry or wet, ") |
- |
1000 |
|
- |
7.3 , Table No. 4 , iv)("Colour fastness to perspiration (contact method)
Grey scale rate, ") |
- |
1000 |
|
- |
7.3 , Table No. 4 , v) , a)(Water vapour permeability,) |
- |
1000 |
|
- |
7.3 , Table No. 4 , v) , b)("Water vapour coefficient,
"
As per IS 15298 (Part 1)) |
- |
1000 |
|
- |
7.4 , Table No. 5 , i)(Thickness) |
- |
1000 |
|
- |
7.4 , Table No. 5 , ii)(Flexing index) |
- |
1000 |
|
- |
7.4 , Table No. 5 , iii)(Abrasion resistance, at 400 cycles) |
- |
1500 |
|
- |
7.4 , Table No. 5 , iv) , a)(Water Absorption,) |
- |
1500 |
|
- |
7.4 , Table No. 5 , iv) , b)(Water Desorption) |
- |
1500 |
|
- |
7.5 , Table No. 6 , i)(Thickness) |
- |
1000 |
|
- |
7.5 , Table No. 6 , ii)(Abrasion resistance, cycles
As per IS 15298 (Part 1)) |
- |
1500 |
|
- |
7.5 , Table No. 6 , iii) , a)(Water Absorption) |
- |
1500 |
|
- |
7.5 , Table No. 6 , iii) , b)(Water Desorption) |
- |
1500 |
|
- |
7.5 , Table No. 6 , iv)(Heat resistance shrinkage linear) |
- |
1000 |
|
- |
7.6 , Table No. 7 , i)(Abrasion resistance (volume loss)) |
- |
1000 |
|
- |
7.6 , Table No. 7 , ii)(Flexing resistance) |
- |
1500 |
|
- |
7.6 , Table No. 7 , iii)(Hydrolysis resistance, cut growth after 1 50 000 flexes) |
- |
1500 |
|
- |
7.6 , Table No. 7 , iv)(Tear strength) |
- |
1000 |
|
- |
7.6 , Table No. 7 , v)(Tensile strength) |
- |
1000 |
|
- |
7.6 , Table No. 7 , vi)(Elongation at break) |
- |
1000 |
|
- |
7.6 , Table No. 7 , vii)(Compression set) |
- |
1000 |
|
- |
7.7 , Table No. 8 , i)(Compression set) |
- |
1000 |
|
- |
7.7 , Table No. 8 , ii)(Split tear strength,) |
- |
1000 |
|
- |
7.7 , Table No. 8 , iii)(Heat shrinkage,) |
- |
1000 |
|
- |
7.7 , Table No. 8 , iv)(Elongation at break,) |
- |
1000 |
|
- |
7.8 , Table No. 9 , i)(First dry collapsing load, hardness) |
- |
0 |
|
Table no. 9 -S.No. 1 to S.No. 4 testing charge- 2500 |
7.8 , Table No. 9 , ii)(Resilience) |
- |
0 |
|
- |
7.8 , Table No. 9 , iii)(Moisture resistance) |
- |
0 |
|
- |
7.8 , Table No. 9 , iv) , a)(Initial dry area shape retention) |
- |
0 |
|
- |
7.8 , Table No. 9 , v)(Peel strength) |
- |
1000 |
|
- |
7.9 , Table No. 10 , i)(Peel strength) |
- |
1500 |
|
- |
7.9 , Table No. 10 , ii)(Shear strength) |
- |
1500 |
|
- |
7.10 , Table No. 11 , i)(Limit of useful extension,) |
- |
1000 |
|
- |
7.10 , Table No. 11 , ii)(Needle strength,) |
- |
1000 |
|
- |
7.11 , Table No. 12 , i)(Breaking strength of lace,) |
- |
1000 |
|
- |
7.11 , Table No. 12 , ii)(Lace tag strength,) |
- |
1000 |
|
- |
7.11 , Table No. 12 , iii)(Lace to lace abrasion,) |
- |
1000 |
|
- |
7.11 , Table No. 12 , iv)("Colour fastness to water
Gray Scale Rate") |
- |
1000 |
|
- |
7.11 , Table No. 12 , v)(Strength of Buckle/Ski hook) |
- |
1000 |
|
- |
7.11 , Table No. 12 , vi)(Corrosion resistance) |
- |
1000 |
|
- |
7.12("Chemical Requirement on Complete Product
for All Types of Sports Shoe") |
- |
35000 |
|
Complete testing charge of chemical requirement- 35000
Lead content- 2500 |
7.12, Table no. 1 of IS 17011,(i)(Allergenic and carcinogenic disperse dyes) |
- |
0 |
|
- |
7.12, Table no. 1 of IS 17011,(ii)(Aromatic amines released from Azo dyes (each individual amine)) |
- |
0 |
|
- |
7.12, Table no. 1 of IS 17011,(iii)(Aromatic amines released from Azo dyes (each individual amine)) |
- |
0 |
|
- |
7.12, Table no. 1 of IS 17011,(iv)(Chromium (VI)) |
- |
0 |
|
- |
7.12, Table no. 1 of IS 17011,(v)(Dimethyl fumarate (DMFU)) |
- |
0 |
|
- |
7.12, Table no. 1 of IS 17011,(vi)(Formaldehyde (free or released by partial hydrolysis)) |
- |
0 |
|
- |
7.12, Table no. 1 of IS 17011,(viii)(Organotin compounds) |
- |
0 |
|
- |
7.12, Table no. 1 of IS 17011,(ix)(PCP-TeCP-TriCP polychlorophenols) |
- |
0 |
|
- |
7.12, Table no. 1 of IS 17011,(x)(pH) |
- |
0 |
|
- |
7.12, Table no. 1 of IS 17011,(xi)(Phthalates (each individual phthalate)) |
- |
0 |
|
- |
7.12, Table no. 1 of IS 17011,(xii)(Nickel, on skin contact 2-(thiocyanomethylthio) -benzothiazole (TCMTB)) |
- |
0 |
|
- |
|
25 Feb, 2027 |
- - |
13 |
IS 17397 : Part 1 (2022) |
PLASTICS THERMOPLASTIC POLYURETHANES FOR MOULDING AND EXTRUSION PART 1 DESIGNATION SYSTEM AND SPECIFICATIONS |
- |
34900 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
4.1(General) |
- |
0 |
|
- |
4.2.1(Data Block 1) |
- |
0 |
|
- |
4.2.2(Data Block 2) |
- |
0 |
|
- |
4.2.3(Data Block 3) |
- |
0 |
|
- |
4.2.4(Data Block 4) |
- |
0 |
|
- |
4.2.5(Data Block 5) |
- |
0 |
|
- |
4.2.5.1(Hardness) |
- |
0 |
|
- |
4.2.5.2(Tensile Modulus of Elasticity) |
- |
0 |
|
- |
4.2.6(Data Block 6) |
- |
0 |
|
- |
6.1(Hardness) |
- |
0 |
|
- |
6.2(Tensile Modulus of Elasticity) |
- |
0 |
|
- |
6.3.1.1(Pigments and Colourants) |
- |
0 |
|
- |
6.3.1.2(Overall Migration) |
- |
0 |
|
- |
7(Packing and Marking) |
- |
0 |
|
- |
|
25 Feb, 2027 |
- Included w.e.f. 24.02.2025 |
14 |
IS 17682 (2021) |
ALUMINIUM COMPOSITE PANEL SPECIFICATION |
- |
42000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Clause 5.1(Polymer Granules) |
- |
5000 |
|
Rs. 42000/- for all test excluding Table 3 & 4
Clause 5.1 Melt flow Index - Rs.2500/-
Ash content - Rs.2500/- |
Clause 5.2(Aluminium Alloy Sheets) |
- |
1000 |
|
Clause 5.2 - Rs.500/-
Clause 5.3 - Rs.500/- |
Clause 5.4(Surface Coating) |
- |
500 |
|
- |
Clause 6(DIMENSIONS AND TOLERANCE) |
- |
3000 |
|
Clause 6.1 - Length - Rs.750/-
Width - Rs.750/-
Clause 6.2 Thickness - Rs.1500/-
Table-1 Edge Straightness - Rs.1500/-
Table-1 Squarenss - Rs.1500/- |
"Clause 7.1 Table 2(i)"(Density of core, g/cm) |
- |
2000 |
|
- |
"Clause 7.1 Table 2(ii)"(Tensile strength,) |
- |
1500 |
|
- |
"Clause 7.1 Table 2(iii)"(Yield strength) |
- |
1500 |
|
- |
"Clause 7.1 Table 2(iv)"(Elongation) |
- |
1500 |
|
- |
"Clause 7.1 Table 2(v)"(Peel strength, N/10 mm width, Min) |
- |
2500 |
|
- |
"Clause 7.1 Table 3(i)"(Coating type) |
- |
2000 |
|
Coating type and Coating Thickness - Rs.2000/- |
"Clause 7.1 Table 3(ii)"(Coating thickness) |
- |
0 |
|
- |
"Clause 7.1 Table 3(iii)"(Adhesion (cross hatch)) |
- |
7000 |
|
Dry - Rs.2000/-
Wet - Rs.2000/-
Boiling water - Rs.3000/- |
"Clause 7.1 Table 3(iv)"(Pencil hardness, Min) |
- |
2000 |
|
- |
"Clause 7.1 Table 3(v)"(Gloss) |
- |
2000 |
|
- |
"Clause 7.1 Table 3(vi)"(Weatherometer test (for 4 000 h)) |
- |
0 |
|
Amendment no.1,Sept.2024
Sl. no. (V)
a).1 Humidity Test - Rs.200,000/-
a).2 Corrosion Test-Rs.200,000/-
b) Weathering test
PVDF/FEVE(2 Coat) - Rs.400,000/-
PVDF/FEVE(3 Coat)- Rs.400,000/-
SDP(2/3 Coat)-Rs.300,000/-
Polyester(1 Coat)-Rs.100,000/- |
"Clause 7.1 Table 3(vii)"(Chemical resistance) |
- |
7500 |
|
Amendment no.1,Sept.2024
a) 1500/-
b) 1500/-
c) 1500/-
d) 1500/-
e) 1500/- |
"Clause 7.1 Table 4(i)"(Limiting oxygen index (LOI), Min) |
- |
15000 |
|
- |
"Clause 7.1 Table 4(ii)"(Smoke density rating, percent, Max) |
- |
15000 |
|
- |
"Clause 7.1 Table 4(iii)"(Ignitability) |
- |
15000 |
|
- |
"Clause 7.1 Table 4(iv)"(Flame spread) |
- |
115000 |
|
- |
"Clause 7.1 Table 4(v)"(Non-combustibility (see Note)) |
- |
35000 |
|
- |
"Clause 7.1 Table 4(vi)"(Oxygen bomb calorimeter) |
- |
15000 |
|
- |
"Clause 7.2 Table 5(i)"(Sound transmission class (STC), dB, Min) |
- |
0 |
|
- |
"Clause 7.2 Table 5(ii)"(Sound absorption coefficient, percent, Min) |
- |
0 |
|
- |
"Clause 7.2 Table 5(iii)"(Coefficient of linear thermal expansion, °C–1 , Max) |
- |
0 |
|
- |
"Clause 7.2 Table 5(iv)"(Thermal Conductivity (W/m2 K), Max) |
- |
0 |
|
- |
Clause 5.1(Polymer Granules) |
- |
0 |
|
- |
Clause 5.2(Aluminium Alloy Sheets) |
- |
0 |
|
- |
Clause 5.4(Surface Coating) |
- |
0 |
|
- |
Clause 6(DIMENSIONS AND TOLERANCE) |
- |
0 |
|
- |
"Clause 7.1 Table 2(i)"(Density of core, g/cm) |
- |
0 |
|
- |
"Clause 7.1 Table 2(ii)"(Tensile strength,) |
- |
0 |
|
- |
"Clause 7.1 Table 2(iii)"(Yield strength) |
- |
0 |
|
- |
"Clause 7.1 Table 2(iv)"(Elongation) |
- |
0 |
|
- |
"Clause 7.1 Table 2(v)"(Peel strength, N/10 mm width, Min) |
- |
0 |
|
- |
"Clause 7.1 Table 3(i)"(Coating type) |
- |
0 |
|
- |
"Clause 7.1 Table 3(ii)"(Coating thickness) |
- |
0 |
|
- |
"Clause 7.1 Table 3(iii)"(Adhesion (cross hatch)) |
- |
0 |
|
- |
"Clause 7.1 Table 3(iv)"(Pencil hardness, Min) |
- |
0 |
|
- |
"Clause 7.1 Table 3(v)"(Gloss) |
- |
0 |
|
- |
"Clause 7.1 Table 3(vi)"(Weatherometer test (for 4 000 h)) |
- |
0 |
|
- |
"Clause 7.1 Table 3(vii)"(Chemical resistance) |
- |
0 |
|
- |
"Clause 7.1 Table 4(i)"(Limiting oxygen index (LOI), Min) |
- |
0 |
|
- |
"Clause 7.1 Table 4(ii)"(Smoke density rating, percent, Max) |
- |
0 |
|
- |
"Clause 7.1 Table 4(iii)"(Ignitability) |
- |
0 |
|
- |
"Clause 7.1 Table 4(iv)"(Flame spread) |
- |
0 |
|
- |
"Clause 7.1 Table 4(v)"(Non-combustibility (see Note)) |
- |
0 |
|
- |
"Clause 7.1 Table 4(vi)"(Oxygen bomb calorimeter) |
- |
0 |
|
- |
"Clause 7.2 Table 5(i)"(Sound transmission class (STC), dB, Min) |
- |
0 |
|
- |
"Clause 7.2 Table 5(ii)"(Sound absorption coefficient, percent, Min) |
- |
0 |
|
- |
"Clause 7.2 Table 5(iii)"(Coefficient of linear thermal expansion, °C–1 , Max) |
- |
0 |
|
- |
"Clause 7.2 Table 5(iv)"(Thermal Conductivity (W/m2 K), Max) |
- |
0 |
|
- |
Clause 5.1(Polymer Granules) |
- |
0 |
|
- |
Clause 5.2(Aluminium Alloy Sheets) |
- |
0 |
|
- |
Clause 5.4(Surface Coating) |
- |
0 |
|
- |
Clause 6.1(Normal dimensions) |
- |
0 |
|
- |
"Clause 7.1 Table 2(i)"(Density of core, g/cm) |
- |
0 |
|
- |
"Clause 7.1 Table 2(ii)"(Tensile strength,) |
- |
0 |
|
- |
"Clause 7.1 Table 2(iii)"(Yield strength) |
- |
0 |
|
- |
"Clause 7.1 Table 2(iv)"(Elongation) |
- |
0 |
|
- |
"Clause 7.1 Table 2(v)"(Peel strength, N/10 mm width, Min) |
- |
0 |
|
- |
"Clause 7.1 Table 3(i)"(Coating type) |
- |
0 |
|
- |
"Clause 7.1 Table 3(ii)"(Coating thickness) |
- |
0 |
|
- |
"Clause 7.1 Table 3(iii)"(Adhesion (cross hatch)) |
- |
0 |
|
- |
"Clause 7.1 Table 3(iv)"(Pencil hardness, Min) |
- |
0 |
|
- |
"Clause 7.1 Table 3(v)"(Gloss) |
- |
0 |
|
- |
"Clause 7.1 Table 3(vi)"(Weatherometer test (for 4 000 h)) |
- |
0 |
|
- |
"Clause 7.1 Table 3(vii)"(Chemical resistance) |
- |
0 |
|
- |
"Clause 7.1 Table 4(i)"(Limiting oxygen index (LOI), Min) |
- |
0 |
|
- |
"Clause 7.1 Table 4(ii)"(Smoke density rating, percent, Max) |
- |
0 |
|
- |
"Clause 7.1 Table 4(iii)"(Ignitability) |
- |
0 |
|
- |
"Clause 7.1 Table 4(iv)"(Flame spread) |
- |
0 |
|
- |
"Clause 7.1 Table 4(v)"(Non-combustibility (see Note)) |
- |
0 |
|
- |
"Clause 7.1 Table 4(vi)"(Oxygen bomb calorimeter) |
- |
0 |
|
- |
"Clause 7.2 Table 5(i)"(Sound transmission class (STC), dB, Min) |
- |
0 |
|
- |
"Clause 7.2 Table 5(ii)"(Sound absorption coefficient, percent, Min) |
- |
0 |
|
- |
"Clause 7.2 Table 5(iii)"(Coefficient of linear thermal expansion, °C–1 , Max) |
- |
0 |
|
- |
"Clause 7.2 Table 5(iv)"(Thermal Conductivity (W/m2 K), Max) |
- |
0 |
|
- |
|
25 Feb, 2027 |
- - |
15 |
IS 17636 (2021) |
Bunk Beds - Specification |
- |
45000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
CLAUSE 4(DESIGN AND WORKMANSHIP) |
- |
45000 |
|
- |
CLAUSE 5(DIMENSIONS) |
- |
45000 |
|
- |
CLAUSE 6(SURFACE PERFORMANCE) |
- |
45000 |
|
- |
CLAUSE 6.2(Fabric and Leather (Synthetic and Natural) Performance) |
- |
45000 |
|
- |
CLAUSE 7.5.1(Attachment, Deflection and Strength of Ladder and Treads) |
- |
45000 |
|
- |
CLAUSE 7.6(Strength of Frame and Fastenings) |
- |
45000 |
|
- |
CLAUSE 7.7(Stability Test) |
- |
45000 |
|
- |
CLAUSE 7.8(Fastening of Upper Bed to Lower Bed) |
- |
45000 |
|
- |
Cl-5(Dimensions) |
- |
45000 |
|
- |
Cl-6.1 (a)(Resistance to mechanical damage) |
- |
45000 |
|
- |
Cl-6.1 (b)(Pencil hardness) |
- |
45000 |
|
- |
Cl-6.1 (c)(Resistance to wet heat) |
- |
45000 |
|
- |
Cl-6.1 (d)(Resistance to dry heat) |
- |
45000 |
|
- |
Cl-6.1 (e)(Resistance to marking by cold liquids) |
- |
45000 |
|
- |
Cl-6.1 (f)(Resistance to marking by cold oils and fats) |
- |
45000 |
|
- |
Cl-6.1 (g)(Adhesive performance) |
- |
45000 |
|
- |
Cl-6.2 (a) 1(Breaking load) |
- |
45000 |
|
- |
Cl-6.2 (a) 2(Elongation at break) |
- |
45000 |
|
- |
Cl-6.2 (a) 3(Tear strength) |
- |
45000 |
|
- |
Cl-6.2 (a) 5(Colour fastness to rubbing) |
- |
45000 |
|
- |
Cl-6.2 (a) 4(Colour fastness to light) |
- |
45000 |
|
- |
Cl-6.2 (a) 6(Colour fastness to perspiration) |
- |
45000 |
|
- |
Cl-6.2 (a) 7(Colour fastness to water) |
- |
45000 |
|
- |
Cl-6.2 (a) 8(Pilling resistance) |
- |
45000 |
|
- |
Cl-6.2 (a) 9(Coating adhesion strength) |
- |
45000 |
|
- |
Cl-6.2 (a) 10(Seam slippage) |
- |
45000 |
|
- |
Cl-6.2 (a) 11(Resistance to damage by flexing) |
- |
45000 |
|
- |
Cl-6.2 (a) 12(Abrasion resistance) |
- |
45000 |
|
- |
Cl-6.2 (a) 13(Bursting strength) |
- |
45000 |
|
- |
Cl-6.2 (a) 14(Resistance to cold) |
- |
45000 |
|
- |
Cl-6.2 (b) 1(Tear strength) |
- |
45000 |
|
- |
Cl-6.2 (b) 2(Flexing endurance) |
- |
45000 |
|
- |
Cl-6.2 (b) 3(Finish adhesion) |
- |
45000 |
|
- |
Cl-6.2 (b) 4(Colour fastness to artificial light) |
- |
45000 |
|
- |
Cl-6.2 (b) 5(Colour fastness to rubbing) |
- |
45000 |
|
- |
Cl-6.2 (b) 6(Colour fastness to water spotting) |
- |
45000 |
|
- |
Cl-6.2 (b) 7(Water vapour permeability) |
- |
45000 |
|
- |
Cl-6.2 (b) 8(Colour fastness to water) |
- |
45000 |
|
- |
Cl-7.1(general test conditions) |
- |
45000 |
|
- |
Cl-7.2.1(Top Bed Safety Barriers) |
- |
45000 |
|
- |
Cl-7.2.2(Top Bed Safety Barriers) |
- |
45000 |
|
- |
Cl-7.2.3(Top Bed Safety Barriers) |
- |
45000 |
|
- |
Cl-7.2.4(Top Bed Safety Barriers) |
- |
45000 |
|
- |
Cl-7.3.1(Gaps) |
- |
45000 |
|
- |
Cl-7.3.2(Gaps) |
- |
45000 |
|
- |
Cl-7.4.1(Bed Base) |
- |
45000 |
|
- |
Cl-7.4.2(Bed Base) |
- |
45000 |
|
- |
Cl-7.5.1(Attachment, Deflection and Strength of Ladder and Treads) |
- |
45000 |
|
- |
Cl-7.5.2(Dimensions of Treads) |
- |
45000 |
|
- |
Cl-7.6(Strength of Frame and Fastenings) |
- |
45000 |
|
- |
Cl-7.7(Stability) |
- |
45000 |
|
- |
Cl-7.8(Fastening of Upper Bed to Lower Bed) |
- |
45000 |
|
- |
Cl-10(Marking) |
- |
45000 |
|
- |
CLAUSE 4(DESIGN AND WORKMANSHIP) |
- |
45000 |
|
- |
CLAUSE 5(DIMENSIONS) |
- |
45000 |
|
- |
CLAUSE 6(SURFACE PERFORMANCE) |
- |
45000 |
|
- |
CLAUSE 6.2(Fabric and Leather (Synthetic and Natural) Performance) |
- |
45000 |
|
- |
CLAUSE 7.5.1(Attachment, Deflection and Strength of Ladder and Treads) |
- |
45000 |
|
- |
CLAUSE 7.6(Strength of Frame and Fastenings) |
- |
45000 |
|
- |
CLAUSE 7.7(Stability Test) |
- |
45000 |
|
- |
CLAUSE 7.8(Fastening of Upper Bed to Lower Bed) |
- |
45000 |
|
- |
Cl-5(Dimensions) |
- |
45000 |
|
- |
Cl-6.1 (a)(Resistance to mechanical damage) |
- |
45000 |
|
- |
Cl-6.1 (b)(Pencil hardness) |
- |
45000 |
|
- |
Cl-6.1 (c)(Resistance to wet heat) |
- |
45000 |
|
- |
Cl-6.1 (d)(Resistance to dry heat) |
- |
45000 |
|
- |
Cl-6.1 (e)(Resistance to marking by cold liquids) |
- |
45000 |
|
- |
Cl-6.1 (f)(Resistance to marking by cold oils and fats) |
- |
45000 |
|
- |
Cl-6.1 (g)(Adhesive performance) |
- |
45000 |
|
- |
Cl-6.2 (a) 1(Breaking load) |
- |
45000 |
|
- |
Cl-6.2 (a) 2(Elongation at break) |
- |
45000 |
|
- |
Cl-6.2 (a) 3(Tear strength) |
- |
45000 |
|
- |
Cl-6.2 (a) 5(Colour fastness to rubbing) |
- |
45000 |
|
- |
Cl-6.2 (a) 4(Colour fastness to light) |
- |
45000 |
|
- |
Cl-6.2 (a) 6(Colour fastness to perspiration) |
- |
45000 |
|
- |
Cl-6.2 (a) 7(Colour fastness to water) |
- |
45000 |
|
- |
Cl-6.2 (a) 8(Pilling resistance) |
- |
45000 |
|
- |
Cl-6.2 (a) 9(Coating adhesion strength) |
- |
45000 |
|
- |
Cl-6.2 (a) 10(Seam slippage) |
- |
45000 |
|
- |
Cl-6.2 (a) 11(Resistance to damage by flexing) |
- |
45000 |
|
- |
Cl-6.2 (a) 12(Abrasion resistance) |
- |
45000 |
|
- |
Cl-6.2 (a) 13(Bursting strength) |
- |
45000 |
|
- |
Cl-6.2 (a) 14(Resistance to cold) |
- |
45000 |
|
- |
Cl-6.2 (b) 1(Tear strength) |
- |
45000 |
|
- |
Cl-6.2 (b) 2(Flexing endurance) |
- |
45000 |
|
- |
Cl-6.2 (b) 3(Finish adhesion) |
- |
45000 |
|
- |
Cl-6.2 (b) 4(Colour fastness to artificial light) |
- |
45000 |
|
- |
Cl-6.2 (b) 5(Colour fastness to rubbing) |
- |
45000 |
|
- |
Cl-6.2 (b) 6(Colour fastness to water spotting) |
- |
45000 |
|
- |
Cl-6.2 (b) 7(Water vapour permeability) |
- |
45000 |
|
- |
Cl-6.2 (b) 8(Colour fastness to water) |
- |
45000 |
|
- |
Cl-7.1(general test conditions) |
- |
45000 |
|
- |
Cl-7.2.1(Top Bed Safety Barriers) |
- |
45000 |
|
- |
Cl-7.2.2(Top Bed Safety Barriers) |
- |
45000 |
|
- |
Cl-7.2.3(Top Bed Safety Barriers) |
- |
45000 |
|
- |
Cl-7.2.4(Top Bed Safety Barriers) |
- |
45000 |
|
- |
Cl-7.3.1(Gaps) |
- |
45000 |
|
- |
Cl-7.3.2(Gaps) |
- |
45000 |
|
- |
Cl-7.4.1(Bed Base) |
- |
45000 |
|
- |
Cl-7.4.2(Bed Base) |
- |
45000 |
|
- |
Cl-7.5.1(Attachment, Deflection and Strength of Ladder and Treads) |
- |
45000 |
|
- |
Cl-7.5.2(Dimensions of Treads) |
- |
45000 |
|
- |
Cl-7.6(Strength of Frame and Fastenings) |
- |
45000 |
|
- |
Cl-7.7(Stability) |
- |
45000 |
|
- |
Cl-7.8(Fastening of Upper Bed to Lower Bed) |
- |
45000 |
|
- |
Cl-10(Marking) |
- |
45000 |
|
- |
|
25 Feb, 2027 |
- Included w.e.f 04.06.2025 |
16 |
IS 15298 : part 4 (2024) |
Personal Protective Equipment Part 4 Occupational Footwear (ISO 20347 : 2021, MOD) (Third Revision) |
- |
53900 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Cl 5.2(Design) |
- |
53900 |
|
- |
Cl 5.2.2(" Height of upper
") |
- |
53900 |
|
- |
Cl 5.2.3(Heel area) |
- |
53900 |
|
- |
Cl 5.3.1.1(Construction of whole footwear) |
- |
53900 |
|
- |
Cl 5.3.1.2(Upper/outsole bond strength) |
- |
53900 |
|
- |
Cl 5.3.2(Leak proofness) |
- |
53900 |
|
- |
Cl 5.3.3(Specific ergonomic features) |
- |
53900 |
|
- |
Cl 5.3.4.2(Slip resistance on ceramic tile floor with sodium lauryl sulphate (NaLS) solution) |
- |
53900 |
|
- |
Cl 5.3.5, Table no 1 of IS 17011,(i)(Allergenic and carcinogenic disperse dyes) |
- |
53900 |
|
- |
Cl 5.3.5, Table no 1 of IS 17011 (ii)(Aromatic amines released from Azo dyes (each individual amine)) |
- |
53900 |
|
- |
Cl 5.3.5, Table no 1 of IS 17011 (iii)(Aromatic amines released from Azo dyes (each individual amine)) |
- |
53900 |
|
- |
Cl 5.3.5, Table no 1 of IS 17011 (iv)(Chromium (VI)) |
- |
53900 |
|
- |
Cl 5.3.5, Table no 1 of IS 17011 (v)(Dimethyl fumarate (DMFU)) |
- |
53900 |
|
- |
Cl 5.3.5, Table no1 of IS 17011 (vi)(Formaldehyde (free or released by partial hydrolysis)) |
- |
53900 |
|
- |
Cl 5.3.5, Table no 1 of IS 17011 (vii)(Formaldehyde) |
- |
53900 |
|
- |
Cl 5.3.5, Table no 1 of IS 17011 (viii)(Organotin compounds) |
- |
53900 |
|
- |
Cl 5.3.5, Table no 1 of IS 17011 (ix)(PCP-TeCP-TriCP polychlorophenols) |
- |
53900 |
|
- |
Cl 5.3.5, Table no 1 of IS 17011 (x)(pH) |
- |
53900 |
|
- |
Cl 5.3.5, Table no 1 of IS 17011 (xi)(Phthalates (each individual phthalate)) |
- |
53900 |
|
- |
Cl 5.3.5, Table no 1 of IS 17011 (xii)(Nickel, on skin contact) |
- |
53900 |
|
- |
Cl 5.3.6(Seam strength) |
- |
53900 |
|
- |
Cl 5.3.7(Lead Content ( National Annex A)) |
- |
53900 |
|
- |
Cl 5.4.1.1(Class I footwear, determination of the area where upper requirements apply of Upper) |
- |
53900 |
|
- |
Cl 5.4.1.2(Hybrid footwear, determination of the area where upper requirements apply of Upper) |
- |
53900 |
|
- |
Cl 5.4.2(Thickness) |
- |
53900 |
|
- |
Cl 5.4.3(Tear strength) |
- |
53900 |
|
- |
Cl 5.4.4, Table 9(Tensile properties- Tensile strength) |
- |
53900 |
|
- |
Cl 5.4.4, Table 9(Tensile properties- Breaking Force) |
- |
53900 |
|
- |
Cl 5.4.4, Table 9(Tensile properties-Modulus at 100 % elongation) |
- |
53900 |
|
- |
Cl 5.4.4, Table 9(Tensile properties- Elongation at break) |
- |
53900 |
|
- |
Cl 5.4.5(Flexing resistance) |
- |
53900 |
|
- |
Cl 5.4.6(Water vapour permeability and coefficient) |
- |
53900 |
|
- |
Cl 5.4.7(Resistance to hydrolysis) |
- |
53900 |
|
- |
Cl 5.5.2(Lining- Tear strength) |
- |
53900 |
|
- |
Cl 5.5.3(Lining- Abrasion resistance) |
- |
53900 |
|
- |
Cl 5.5.4(Lining-Water vapour permeability and coefficient) |
- |
53900 |
|
- |
Cl 5.6.2(Tear strength of tongue) |
- |
53900 |
|
- |
Cl 5.7.1(Thickness of Insole, insock and footbed) |
- |
53900 |
|
- |
Cl 5.7.2(Water permeability of insock) |
- |
53900 |
|
- |
Cl 5.7.3(Water absorption and desorption of Insole, insock and footbed) |
- |
53900 |
|
- |
Cl 5.7.4.1(Abrasion resistance of Insoles) |
- |
53900 |
|
- |
Cl 5.7.4.2(Abrasion resistance of Insocks) |
- |
53900 |
|
- |
Cl 5.8.2.1(Thickness of Outsole) |
- |
53900 |
|
- |
Cl 5.8.2.2(Cleated area) |
- |
53900 |
|
- |
Cl 5.8.2.3(Cleat height) |
- |
53900 |
|
- |
Cl 5.8.3(Outsole- Tear strength) |
- |
53900 |
|
- |
Cl 5.8.4(Outsole- Abrasion resistance) |
- |
53900 |
|
- |
Cl 5.8.5(Outsole-Flexing resistance) |
- |
53900 |
|
- |
Cl 5.8.6(Outsole-Resistance to hydrolysis) |
- |
53900 |
|
- |
Cl 5.8.7(Interlayer bond strength) |
- |
53900 |
|
- |
Cl 6.2.1.1.2(Metallic perforation-resistant inserts (Type P)) |
- |
53900 |
|
- |
Cl 6.2.1.1.3(Non-metallic perforation-resistant inserts and insoles (Type PL)) |
- |
53900 |
|
- |
Cl 6.2.1.1.4(Non-metallic perforation-resistant inserts and insoles (Type PS)) |
- |
53900 |
|
- |
Cl 6.2.1.2(Construction of perforation resistant insert) |
- |
53900 |
|
- |
Cl 6.2.1.3(Dimensions of perforation resistant insert) |
- |
53900 |
|
- |
Cl 6.2.1.4.1(Flex resistance of perforation-resistant inserts) |
- |
53900 |
|
- |
Cl 6.2.1.4.2.1(ISO 20344:2021, 5.11.2) |
- |
53900 |
|
- |
Cl 6.2.1.4.2.2(ISO 20344:2021, 5.6.2.1) |
- |
53900 |
|
- |
Cl 6.2.1.4.3(Stability against ageing and environmental influence of non-metallic perforationresistant inserts) |
- |
53900 |
|
- |
Cl 6.2.2.1(Electrical properties of Partially conductive footwear) |
- |
53900 |
|
- |
Cl 6.2.2.2(Electrical properties of Antistatic footwear) |
- |
53900 |
|
- |
Cl 6.2.3.1(Heat insulation of outsole complex) |
- |
53900 |
|
- |
Cl 6.2.3.2(Cold insulation of outsole complex) |
- |
53900 |
|
- |
Cl 6.2.4(Energy absorption of seat region) |
- |
53900 |
|
- |
Cl 6.2.5(Water resistance) |
- |
53900 |
|
- |
Cl 6.2.6(Ankle protection) |
- |
53900 |
|
- |
Cl 6.2.7.1(Cut resistance footwear- design) |
- |
53900 |
|
- |
Cl 6.2.7.2(Dimensions and construction of protective area of Cut resistance footwear) |
- |
53900 |
|
- |
Cl 6.2.7.3(Resistance to cutting) |
- |
53900 |
|
- |
Cl 6.2.8(Scuff cap) |
- |
53900 |
|
- |
Cl 6.2.9("Slip resistance on ceramic tile floor with glycerine
") |
- |
53900 |
|
- |
Cl 6.3(Upper — Water penetration and absorption) |
- |
53900 |
|
- |
Cl 6.4.1(Resistance to hot contact - Outsole) |
- |
53900 |
|
- |
Cl 6.4.2(Resistance to fuel oil - Outsole) |
- |
53900 |
|
- |
Cl 6.4.3.1(Mechanical properties of Ladder grip) |
- |
53900 |
|
- |
Cl 6.4.3.2(Design of Ladder grip) |
- |
53900 |
|
- |
Cl 6.4.3.3(Cleat height in the waist area of Ladder grip) |
- |
53900 |
|
- |
Cl 6.4.3.4(Heel breast of Ladder grip) |
- |
53900 |
|
- |
Cl 7("Marking
") |
- |
53900 |
|
- |
Cl 5.2(Design) |
- |
53900 |
|
- |
Cl 5.2.2(" Height of upper
") |
- |
53900 |
|
- |
Cl 5.2.3(Heel area) |
- |
53900 |
|
- |
Cl 5.3.1.1(Construction of whole footwear) |
- |
53900 |
|
- |
Cl 5.3.1.2(Upper/outsole bond strength) |
- |
53900 |
|
- |
Cl 5.3.2(Leak proofness) |
- |
53900 |
|
- |
Cl 5.3.3(Specific ergonomic features) |
- |
53900 |
|
- |
Cl 5.3.4.2(Slip resistance on ceramic tile floor with sodium lauryl sulphate (NaLS) solution) |
- |
53900 |
|
- |
Cl 5.3.5, Table no 1 of IS 17011,(i)(Allergenic and carcinogenic disperse dyes) |
- |
53900 |
|
- |
Cl 5.3.5, Table no 1 of IS 17011 (ii)(Aromatic amines released from Azo dyes (each individual amine)) |
- |
53900 |
|
- |
Cl 5.3.5, Table no 1 of IS 17011 (iii)(Aromatic amines released from Azo dyes (each individual amine)) |
- |
53900 |
|
- |
Cl 5.3.5, Table no 1 of IS 17011 (iv)(Chromium (VI)) |
- |
53900 |
|
- |
Cl 5.3.5, Table no 1 of IS 17011 (v)(Dimethyl fumarate (DMFU)) |
- |
53900 |
|
- |
Cl 5.3.5, Table no1 of IS 17011 (vi)(Formaldehyde (free or released by partial hydrolysis)) |
- |
53900 |
|
- |
Cl 5.3.5, Table no 1 of IS 17011 (vii)(Formaldehyde) |
- |
53900 |
|
- |
Cl 5.3.5, Table no 1 of IS 17011 (viii)(Organotin compounds) |
- |
53900 |
|
- |
Cl 5.3.5, Table no 1 of IS 17011 (ix)(PCP-TeCP-TriCP polychlorophenols) |
- |
53900 |
|
- |
Cl 5.3.5, Table no 1 of IS 17011 (x)(pH) |
- |
53900 |
|
- |
Cl 5.3.5, Table no 1 of IS 17011 (xi)(Phthalates (each individual phthalate)) |
- |
53900 |
|
- |
Cl 5.3.5, Table no 1 of IS 17011 (xii)(Nickel, on skin contact) |
- |
53900 |
|
- |
Cl 5.3.6(Seam strength) |
- |
53900 |
|
- |
Cl 5.3.7(Lead Content ( National Annex A)) |
- |
53900 |
|
- |
Cl 5.4.1.1(Class I footwear, determination of the area where upper requirements apply of Upper) |
- |
53900 |
|
- |
Cl 5.4.1.2(Hybrid footwear, determination of the area where upper requirements apply of Upper) |
- |
53900 |
|
- |
Cl 5.4.2(Thickness) |
- |
53900 |
|
- |
Cl 5.4.3(Tear strength) |
- |
53900 |
|
- |
Cl 5.4.4, Table 9(Tensile properties- Tensile strength) |
- |
53900 |
|
- |
Cl 5.4.4, Table 9(Tensile properties- Breaking Force) |
- |
53900 |
|
- |
Cl 5.4.4, Table 9(Tensile properties-Modulus at 100 % elongation) |
- |
53900 |
|
- |
Cl 5.4.4, Table 9(Tensile properties- Elongation at break) |
- |
53900 |
|
- |
Cl 5.4.5(Flexing resistance) |
- |
53900 |
|
- |
Cl 5.4.6(Water vapour permeability and coefficient) |
- |
53900 |
|
- |
Cl 5.4.7(Resistance to hydrolysis) |
- |
53900 |
|
- |
Cl 5.5.2(Lining- Tear strength) |
- |
53900 |
|
- |
Cl 5.5.3(Lining- Abrasion resistance) |
- |
53900 |
|
- |
Cl 5.5.4(Lining-Water vapour permeability and coefficient) |
- |
53900 |
|
- |
Cl 5.6.2(Tear strength of tongue) |
- |
53900 |
|
- |
Cl 5.7.1(Thickness of Insole, insock and footbed) |
- |
53900 |
|
- |
Cl 5.7.2(Water permeability of insock) |
- |
53900 |
|
- |
Cl 5.7.3(Water absorption and desorption of Insole, insock and footbed) |
- |
53900 |
|
- |
Cl 5.7.4.1(Abrasion resistance of Insoles) |
- |
53900 |
|
- |
Cl 5.7.4.2(Abrasion resistance of Insocks) |
- |
53900 |
|
- |
Cl 5.8.2.1(Thickness of Outsole) |
- |
53900 |
|
- |
Cl 5.8.2.2(Cleated area) |
- |
53900 |
|
- |
Cl 5.8.2.3(Cleat height) |
- |
53900 |
|
- |
Cl 5.8.3(Outsole- Tear strength) |
- |
53900 |
|
- |
Cl 5.8.4(Outsole- Abrasion resistance) |
- |
53900 |
|
- |
Cl 5.8.5(Outsole-Flexing resistance) |
- |
53900 |
|
- |
Cl 5.8.6(Outsole-Resistance to hydrolysis) |
- |
53900 |
|
- |
Cl 5.8.7(Interlayer bond strength) |
- |
53900 |
|
- |
Cl 6.2.1.1.2(Metallic perforation-resistant inserts (Type P)) |
- |
53900 |
|
- |
Cl 6.2.1.1.3(Non-metallic perforation-resistant inserts and insoles (Type PL)) |
- |
53900 |
|
- |
Cl 6.2.1.1.4(Non-metallic perforation-resistant inserts and insoles (Type PS)) |
- |
53900 |
|
- |
Cl 6.2.1.2(Construction of perforation resistant insert) |
- |
53900 |
|
- |
Cl 6.2.1.3(Dimensions of perforation resistant insert) |
- |
53900 |
|
- |
Cl 6.2.1.4.1(Flex resistance of perforation-resistant inserts) |
- |
53900 |
|
- |
Cl 6.2.1.4.2.1(ISO 20344:2021, 5.11.2) |
- |
53900 |
|
- |
Cl 6.2.1.4.2.2(ISO 20344:2021, 5.6.2.1) |
- |
53900 |
|
- |
Cl 6.2.1.4.3(Stability against ageing and environmental influence of non-metallic perforationresistant inserts) |
- |
53900 |
|
- |
Cl 6.2.2.1(Electrical properties of Partially conductive footwear) |
- |
53900 |
|
- |
Cl 6.2.2.2(Electrical properties of Antistatic footwear) |
- |
53900 |
|
- |
Cl 6.2.3.1(Heat insulation of outsole complex) |
- |
53900 |
|
- |
Cl 6.2.3.2(Cold insulation of outsole complex) |
- |
53900 |
|
- |
Cl 6.2.4(Energy absorption of seat region) |
- |
53900 |
|
- |
Cl 6.2.5(Water resistance) |
- |
53900 |
|
- |
Cl 6.2.6(Ankle protection) |
- |
53900 |
|
- |
Cl 6.2.7.1(Cut resistance footwear- design) |
- |
53900 |
|
- |
Cl 6.2.7.2(Dimensions and construction of protective area of Cut resistance footwear) |
- |
53900 |
|
- |
Cl 6.2.7.3(Resistance to cutting) |
- |
53900 |
|
- |
Cl 6.2.8(Scuff cap) |
- |
53900 |
|
- |
Cl 6.2.9("Slip resistance on ceramic tile floor with glycerine
") |
- |
53900 |
|
- |
Cl 6.3(Upper — Water penetration and absorption) |
- |
53900 |
|
- |
Cl 6.4.1(Resistance to hot contact - Outsole) |
- |
53900 |
|
- |
Cl 6.4.2(Resistance to fuel oil - Outsole) |
- |
53900 |
|
- |
Cl 6.4.3.1(Mechanical properties of Ladder grip) |
- |
53900 |
|
- |
Cl 6.4.3.2(Design of Ladder grip) |
- |
53900 |
|
- |
Cl 6.4.3.3(Cleat height in the waist area of Ladder grip) |
- |
53900 |
|
- |
Cl 6.4.3.4(Heel breast of Ladder grip) |
- |
53900 |
|
- |
Cl 7("Marking
") |
- |
53900 |
|
- |
|
25 Feb, 2027 |
- Included w.e.f 13.03.2025 |
17 |
IS 17635 (2022) |
Beds - Specification |
- |
60000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
CLAUSE 4(Design and workmanship) |
- |
60000 |
|
- |
CLAUSE 5(Dimensions) |
- |
60000 |
|
- |
CLAUSE 6(SURFACE PERFORMANCE) |
- |
60000 |
|
- |
CLAUSE 6.2(Fabric and Leather (Synthetic and Natural) Performance) |
- |
60000 |
|
- |
CLAUSE 7(SAFETY TESTS) |
- |
60000 |
|
- |
CLAUSE 7.3(Stability Test) |
- |
60000 |
|
- |
CLAUSE 7.4(Vertical Static Load Tests) |
- |
60000 |
|
- |
CLAUSE 7.5(Horizontal Static Load Tests) |
- |
60000 |
|
- |
CLAUSE 7.5.2(Horizontal Static Load Test of Beds Without Headboard) |
- |
60000 |
|
- |
CLAUSE 7.6.1(Vertical Durability Test of Bed Base) |
- |
60000 |
|
- |
CLAUSE 7.6.2(Horizontal Durability Test of Bed Frame) |
- |
60000 |
|
- |
CLAUSE 7.6.3(Horizontal Durability Test of Headboards) |
- |
60000 |
|
- |
CLAUSE 7.7(Vertical Impact Test) |
- |
60000 |
|
- |
CLAUSE 8.1(Mechanisms for Lifting Bed Bases) |
- |
60000 |
|
- |
CLAUSE 8.2(Extendable Storage Elements) |
- |
60000 |
|
- |
Cl-5(Dimensions) |
- |
60000 |
|
- |
Cl-6.1 (a)(Resistance to mechanical damage) |
- |
60000 |
|
- |
Cl-6.1 (b)(Pencil hardness) |
- |
60000 |
|
- |
Cl-6.1 (c)(Resistance to wet heat) |
- |
60000 |
|
- |
Cl-6.1 (d)(Resistance to dry heat) |
- |
60000 |
|
- |
Cl-6.1 (e)(Resistance to marking by cold liquids) |
- |
60000 |
|
- |
Cl-6.1 (f)(Resistance to marking by cold oils and fats) |
- |
60000 |
|
- |
Cl-6.1 (g)(Adhesive performance) |
- |
60000 |
|
- |
Cl-6.2 (a) 1(Breaking load) |
- |
60000 |
|
- |
Cl-6.2 (a) 2(Elongation at break) |
- |
60000 |
|
- |
Cl-6.2 (a) 3(Tear strength) |
- |
60000 |
|
- |
Cl-6.2 (a) 4(Colour fastness to light) |
- |
60000 |
|
- |
Cl-6.2 (a) 5(Colour fastness to rubbing) |
- |
60000 |
|
- |
Cl-6.2 (a) 6(Colour fastness to perspiration) |
- |
60000 |
|
- |
Cl-6.2 (a) 7(Colour fastness to water) |
- |
60000 |
|
- |
Cl-6.2 (a) 8(Pilling resistance) |
- |
60000 |
|
- |
Cl-6.2 (a) 9(Coating adhesion strength) |
- |
60000 |
|
- |
Cl-6.2 (a) 10(Seam slippage) |
- |
60000 |
|
- |
Cl-6.2 (a) 11(Resistance to damage by flexing) |
- |
60000 |
|
- |
Cl-6.2 (a) 12(Abrasion resistance) |
- |
60000 |
|
- |
Cl-6.2 (a) 13(Bursting strength) |
- |
60000 |
|
- |
Cl-6.2 (a) 14(Resistance to cold) |
- |
60000 |
|
- |
Cl-6.2 (b) 1(Tear strength) |
- |
60000 |
|
- |
Cl-6.2 (b) 2(Flexing endurance) |
- |
60000 |
|
- |
Cl-6.2 (b) 3(Finish adhesion) |
- |
60000 |
|
- |
Cl-6.2 (b) 4(Colour fastness to artificial light) |
- |
60000 |
|
- |
Cl-6.2 (b) 5(Colour fastness to rubbing) |
- |
60000 |
|
- |
Cl-6.2 (b) 6(Colour fastness to water spotting) |
- |
60000 |
|
- |
Cl-6.2 (b) 7(Water vapour permeability) |
- |
60000 |
|
- |
Cl-6.2 (b) 8(Colour fastness to water) |
- |
60000 |
|
- |
Cl-7.1(Safety Tests) |
- |
60000 |
|
- |
Cl-7.2(Safety Tests) |
- |
60000 |
|
- |
Cl-7.3(Stability Test) |
- |
60000 |
|
- |
Cl-7.4.1(Vertical Static Load on Bed Base) |
- |
60000 |
|
- |
Cl-7.4.2(Vertical Static Load on Side Rail) |
- |
60000 |
|
- |
Cl-7.5.1(Horizontal Static Load on Headboard) |
- |
60000 |
|
- |
Cl-7.5.2(Horizontal Static Load Test of Beds Without Headboard) |
- |
60000 |
|
- |
Cl-7.6.1(Vertical Durability Test of Bed Base) |
- |
60000 |
|
- |
Cl-7.6.2(Horizontal Durability Test of Bed Frame) |
- |
60000 |
|
- |
Cl-7.6.3(Horizontal Durability Test of Headboards) |
- |
60000 |
|
- |
Cl-7.7(Vertical Impact Test) |
- |
60000 |
|
- |
Cl-8.1.2(Durability of Mechanisms for Lifting Bed Bases) |
- |
60000 |
|
- |
Cl-8.2.2(Durability of Extendable Storage Elements) |
- |
60000 |
|
- |
Cl-10(Marking) |
- |
60000 |
|
- |
|
25 Feb, 2027 |
- Included w.e.f 04.06.2025 |
18 |
IS 15298 : Part 3 (2024) |
Personal Protective Equipment Part 3 Protective Footwear (ISO 20346 : 2021, MOD) (Third Revision) |
- |
53900 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Cl 5.2(Design) |
- |
53900 |
|
- |
Cl 5.2.2(" Height of upper
") |
- |
53900 |
|
- |
Cl 5.2.3(Heel area) |
- |
53900 |
|
- |
Cl 5.3.1.1(Construction of whole footwear) |
- |
53900 |
|
- |
Cl 5.3.1.2(Upper/outsole bond strength) |
- |
53900 |
|
- |
Cl 5.3.2.1(Toe protection - general) |
- |
53900 |
|
- |
Cl 5.3.2.2(Internal length) |
- |
53900 |
|
- |
Cl 5.3.2.3(Width of toecap flange) |
- |
53900 |
|
- |
Cl 5.3.2.4.1(Corrosion resistance of Class I footwear and hybrid mounted footwear) |
- |
53900 |
|
- |
Cl 5.3.2.4.2(Corrosion resistance of Class II and hybrid moulded footwear) |
- |
53900 |
|
- |
Cl 5.3.2.5(Behaviour of toecaps (thermal and chemical) of Corrosion resistance) |
- |
53900 |
|
- |
Cl 5.3.2.6(Impact resistance) |
- |
53900 |
|
- |
Cl 5.3.2.7(Compression resistance) |
- |
53900 |
|
- |
Cl 5.3.3(Leak proofness) |
- |
53900 |
|
- |
Cl 5.3.4("Specific ergonomic features
") |
- |
53900 |
|
- |
Cl 5.3.5.2(Slip resistance on ceramic tile floor with sodium lauryl sulphate (NaLS) solution) |
- |
53900 |
|
- |
Cl 5.3.6, Table no 1 of IS 17011 (i)(Allergenic and carcinogenic disperse dyes) |
- |
53900 |
|
- |
Cl 5.3.6, Table no 1 of IS 17011 (ii)(Aromatic amines released from Azo dyes (each individual amine)) |
- |
53900 |
|
- |
Cl 5.3.6, Table no 1 of IS 17011 (iii)(Aromatic amines released from Azo dyes (each individual amine)) |
- |
53900 |
|
- |
Cl 5.3.6, Table no 1 of IS 17011 (iv)(Chromium (VI)) |
- |
53900 |
|
- |
Cl 5.3.6, Table no 1 of IS 17011 (v)(Dimethyl fumarate (DMFU)) |
- |
53900 |
|
- |
Cl 5.3.6, Table no1 of IS 17011 (vi)(Formaldehyde (free or released by partial hydrolysis)) |
- |
53900 |
|
- |
Cl 5.3.6, Table no 1 of IS 17011 (vii)(Formaldehyde) |
- |
53900 |
|
- |
Cl 5.3.6, Table no 1 of IS 17011 (viii)(Organotin compounds) |
- |
53900 |
|
- |
Cl 5.3.6, Table no 1 of IS 17011 (ix)(PCP-TeCP-TriCP polychlorophenols) |
- |
53900 |
|
- |
Cl 5.3.6, Table no 1 of IS 17011 (x)(pH) |
- |
53900 |
|
- |
Cl 5.3.6, Table no 1 of IS 17011 (xi)(Phthalates (each individual phthalate)) |
- |
53900 |
|
- |
Cl 5.3.6, Table no 1 of IS 17011 (xii)(Nickel, on skin contact) |
- |
53900 |
|
- |
Cl 5.3.7(Seam strength) |
- |
53900 |
|
- |
Cl 5.3.8(Lead Content ( National Annex A)) |
- |
53900 |
|
- |
Cl 5.4.1.1(Class I footwear, determination of the area where upper requirements apply of Upper) |
- |
53900 |
|
- |
Cl 5.4.1.2(Hybrid footwear, determination of the area where upper requirements apply of Upper) |
- |
53900 |
|
- |
Cl 5.4.2(Thickness) |
- |
53900 |
|
- |
Cl 5.4.3(Tear strength) |
- |
53900 |
|
- |
Cl 5.4.4, Table 11(Tensile properties- Tensile strength) |
- |
53900 |
|
- |
Cl 5.4.4, Table 11(Tensile properties- Breaking Force) |
- |
53900 |
|
- |
Cl 5.4.4, Table 11(Tensile properties-Modulus at 100 % elongation) |
- |
53900 |
|
- |
Cl 5.4.4, Table 11(Tensile properties- Elongation at break) |
- |
53900 |
|
- |
Cl 5.4.4, Table 11(Tensile properties- Elongation at break) |
- |
53900 |
|
- |
Cl 5.4.6(Water vapour permeability and coefficient) |
- |
53900 |
|
- |
Cl 5.4.7(Resistance to hydrolysis) |
- |
53900 |
|
- |
Cl 5.5.2(Lining- Tear strength) |
- |
53900 |
|
- |
Cl 5.5.3(Lining- Abrasion resistance) |
- |
53900 |
|
- |
Cl 5.5.4(Lining-Water vapour permeability and coefficient) |
- |
53900 |
|
- |
Cl 5.6.2(Tear strength of tongue) |
- |
53900 |
|
- |
Cl 5.7.1(Thickness of Insole, insock and footbed) |
- |
53900 |
|
- |
Cl 5.7.2(Water permeability of insock) |
- |
53900 |
|
- |
Cl 5.7.3(Water absorption and desorption of Insole, insock and footbed) |
- |
53900 |
|
- |
Cl 5.7.4.1(Abrasion resistance of Insoles) |
- |
53900 |
|
- |
Cl 5.7.4.2(Abrasion resistance of Insocks) |
- |
53900 |
|
- |
Cl 5.8.2.1(Thickness of Outsole) |
- |
53900 |
|
- |
Cl 5.8.2.2(Cleated area) |
- |
53900 |
|
- |
Cl 5.8.2.3(Cleat height) |
- |
53900 |
|
- |
Cl 5.8.3(Outsole- Tear strength) |
- |
53900 |
|
- |
Cl 5.8.4(Outsole- Abrasion resistance) |
- |
53900 |
|
- |
Cl 5.8.5(Outsole-Flexing resistance) |
- |
53900 |
|
- |
Cl 5.8.6(Outsole-Resistance to hydrolysis) |
- |
53900 |
|
- |
Cl 5.8.7(Interlayer bond strength) |
- |
53900 |
|
- |
Cl 6.2.1.1.2(Metallic perforation-resistant inserts (Type P)) |
- |
53900 |
|
- |
Cl 6.2.1.1.3(Non-metallic perforation-resistant inserts and insoles (Type PL)) |
- |
53900 |
|
- |
Cl 6.2.1.1.4(Non-metallic perforation-resistant inserts and insoles (Type PS)) |
- |
53900 |
|
- |
Cl 6.2.1.2(Construction of perforation resistant insert) |
- |
53900 |
|
- |
Cl 6.2.1.3(Dimensions of perforation resistant insert) |
- |
53900 |
|
- |
Cl 6.2.1.4.1(Flex resistance of perforation-resistant inserts) |
- |
53900 |
|
- |
Cl 6.2.1.4.2.1(Corrosion resistance of perforation resistant metallic insert for Class I footwear and hybrid mounted footwear) |
- |
53900 |
|
- |
Cl 6.2.1.4.2.2(Corrosion resistance of perforation resistant metallic insert for Class II footwear and hybrid moulded footwear) |
- |
53900 |
|
- |
Cl 6.2.1.4.3(Stability against ageing and environmental influence of non-metallic perforationresistant inserts) |
- |
53900 |
|
- |
Cl 6.2.2.1(Electrical properties of Partially conductive footwear) |
- |
53900 |
|
- |
Cl 6.2.2.2(Electrical properties of Antistatic footwear) |
- |
53900 |
|
- |
Cl 6.2.3.1(Heat insulation of outsole complex) |
- |
53900 |
|
- |
Cl 6.2.3.2(Cold insulation of outsole complex) |
- |
53900 |
|
- |
Cl 6.2.4(Energy absorption of seat region) |
- |
53900 |
|
- |
Cl 6.2.5(Water resistance) |
- |
53900 |
|
- |
Cl 6.2.6.1(Metatarsal protection - Construction) |
- |
53900 |
|
- |
Cl 6.2.6.2("Metatarsal protection-Impact resistance of metatarsal protective device
") |
- |
53900 |
|
- |
Cl 6.2.7(Ankle protection) |
- |
53900 |
|
- |
Cl 6.2.8.2(Cut resistance footwear- design) |
- |
53900 |
|
- |
Cl 6.2.8.2(Dimensions and construction of protective area of Cut resistance footwear) |
- |
53900 |
|
- |
Cl 6.2.8.3(Resistance to cutting) |
- |
53900 |
|
- |
Cl 6.2.9(Scuff cap) |
- |
53900 |
|
- |
Cl 6.2.10("Slip resistance on ceramic tile floor with glycerine
") |
- |
53900 |
|
- |
Cl 6.3(Upper — Water penetration and absorption) |
- |
53900 |
|
- |
Cl 6.4.1(Resistance to hot contact - Outsole) |
- |
53900 |
|
- |
Cl 6.4.2(Resistance to fuel oil - Outsole) |
- |
53900 |
|
- |
Cl 6.4.3.1(Mechanical properties of Ladder grip) |
- |
53900 |
|
- |
Cl 6.4.3.2(Design of Ladder grip) |
- |
53900 |
|
- |
Cl 6.4.3.3(Cleat height in the waist area of Ladder grip) |
- |
53900 |
|
- |
Cl 6.4.3.4(Heel breast of Ladder grip) |
- |
53900 |
|
- |
Cl 7("Marking
") |
- |
53900 |
|
- |
Cl 7("Marking
") |
- |
53900 |
|
- |
Cl 5.2(Design) |
- |
53900 |
|
- |
Cl 5.2.2(" Height of upper
") |
- |
53900 |
|
- |
Cl 5.2.3(Heel area) |
- |
53900 |
|
- |
Cl 5.3.1.1(Construction of whole footwear) |
- |
53900 |
|
- |
Cl 5.3.1.2(Upper/outsole bond strength) |
- |
53900 |
|
- |
Cl 5.3.2.1(Toe protection - general) |
- |
53900 |
|
- |
Cl 5.3.2.2(Internal length) |
- |
53900 |
|
- |
Cl 5.3.2.3(Width of toecap flange) |
- |
53900 |
|
- |
Cl 5.3.2.4.1(Corrosion resistance of Class I footwear and hybrid mounted footwear) |
- |
53900 |
|
- |
Cl 5.3.2.4.2(Corrosion resistance of Class II and hybrid moulded footwear) |
- |
53900 |
|
- |
Cl 5.3.2.5(Behaviour of toecaps (thermal and chemical) of Corrosion resistance) |
- |
53900 |
|
- |
Cl 5.3.2.6(Impact resistance) |
- |
53900 |
|
- |
Cl 5.3.2.7(Compression resistance) |
- |
53900 |
|
- |
Cl 5.3.3(Leak proofness) |
- |
53900 |
|
- |
Cl 5.3.4("Specific ergonomic features
") |
- |
53900 |
|
- |
Cl 5.3.5.2(Slip resistance on ceramic tile floor with sodium lauryl sulphate (NaLS) solution) |
- |
53900 |
|
- |
Cl 5.3.6, Table no 1 of IS 17011 (i)(Allergenic and carcinogenic disperse dyes) |
- |
53900 |
|
- |
Cl 5.3.6, Table no 1 of IS 17011 (ii)(Aromatic amines released from Azo dyes (each individual amine)) |
- |
53900 |
|
- |
Cl 5.3.6, Table no 1 of IS 17011 (iii)(Aromatic amines released from Azo dyes (each individual amine)) |
- |
53900 |
|
- |
Cl 5.3.6, Table no 1 of IS 17011 (iv)(Chromium (VI)) |
- |
53900 |
|
- |
Cl 5.3.6, Table no 1 of IS 17011 (v)(Dimethyl fumarate (DMFU)) |
- |
53900 |
|
- |
Cl 5.3.6, Table no1 of IS 17011 (vi)(Formaldehyde (free or released by partial hydrolysis)) |
- |
53900 |
|
- |
Cl 5.3.6, Table no 1 of IS 17011 (vii)(Formaldehyde) |
- |
53900 |
|
- |
Cl 5.3.6, Table no 1 of IS 17011 (viii)(Organotin compounds) |
- |
53900 |
|
- |
Cl 5.3.6, Table no 1 of IS 17011 (ix)(PCP-TeCP-TriCP polychlorophenols) |
- |
53900 |
|
- |
Cl 5.3.6, Table no 1 of IS 17011 (x)(pH) |
- |
53900 |
|
- |
Cl 5.3.6, Table no 1 of IS 17011 (xi)(Phthalates (each individual phthalate)) |
- |
53900 |
|
- |
Cl 5.3.6, Table no 1 of IS 17011 (xii)(Nickel, on skin contact) |
- |
53900 |
|
- |
Cl 5.3.7(Seam strength) |
- |
53900 |
|
- |
Cl 5.3.8(Lead Content ( National Annex A)) |
- |
53900 |
|
- |
Cl 5.4.1.1(Class I footwear, determination of the area where upper requirements apply of Upper) |
- |
53900 |
|
- |
Cl 5.4.1.2(Hybrid footwear, determination of the area where upper requirements apply of Upper) |
- |
53900 |
|
- |
Cl 5.4.2(Thickness) |
- |
53900 |
|
- |
Cl 5.4.3(Tear strength) |
- |
53900 |
|
- |
Cl 5.4.4, Table 11(Tensile properties- Tensile strength) |
- |
53900 |
|
- |
Cl 5.4.4, Table 11(Tensile properties- Breaking Force) |
- |
53900 |
|
- |
Cl 5.4.4, Table 11(Tensile properties-Modulus at 100 % elongation) |
- |
53900 |
|
- |
Cl 5.4.4, Table 11(Tensile properties- Elongation at break) |
- |
53900 |
|
- |
Cl 5.4.4, Table 11(Tensile properties- Elongation at break) |
- |
53900 |
|
- |
Cl 5.4.6(Water vapour permeability and coefficient) |
- |
53900 |
|
- |
Cl 5.4.7(Resistance to hydrolysis) |
- |
53900 |
|
- |
Cl 5.5.2(Lining- Tear strength) |
- |
53900 |
|
- |
Cl 5.5.3(Lining- Abrasion resistance) |
- |
53900 |
|
- |
Cl 5.5.4(Lining-Water vapour permeability and coefficient) |
- |
53900 |
|
- |
Cl 5.6.2(Tear strength of tongue) |
- |
53900 |
|
- |
Cl 5.7.1(Thickness of Insole, insock and footbed) |
- |
53900 |
|
- |
Cl 5.7.2(Water permeability of insock) |
- |
53900 |
|
- |
Cl 5.7.3(Water absorption and desorption of Insole, insock and footbed) |
- |
53900 |
|
- |
Cl 5.7.4.1(Abrasion resistance of Insoles) |
- |
53900 |
|
- |
Cl 5.7.4.2(Abrasion resistance of Insocks) |
- |
53900 |
|
- |
Cl 5.8.2.1(Thickness of Outsole) |
- |
53900 |
|
- |
Cl 5.8.2.2(Cleated area) |
- |
53900 |
|
- |
Cl 5.8.2.3(Cleat height) |
- |
53900 |
|
- |
Cl 5.8.3(Outsole- Tear strength) |
- |
53900 |
|
- |
Cl 5.8.4(Outsole- Abrasion resistance) |
- |
53900 |
|
- |
Cl 5.8.5(Outsole-Flexing resistance) |
- |
53900 |
|
- |
Cl 5.8.6(Outsole-Resistance to hydrolysis) |
- |
53900 |
|
- |
Cl 5.8.7(Interlayer bond strength) |
- |
53900 |
|
- |
Cl 6.2.1.1.2(Metallic perforation-resistant inserts (Type P)) |
- |
53900 |
|
- |
Cl 6.2.1.1.3(Non-metallic perforation-resistant inserts and insoles (Type PL)) |
- |
53900 |
|
- |
Cl 6.2.1.1.4(Non-metallic perforation-resistant inserts and insoles (Type PS)) |
- |
53900 |
|
- |
Cl 6.2.1.2(Construction of perforation resistant insert) |
- |
53900 |
|
- |
Cl 6.2.1.3(Dimensions of perforation resistant insert) |
- |
53900 |
|
- |
Cl 6.2.1.4.1(Flex resistance of perforation-resistant inserts) |
- |
53900 |
|
- |
Cl 6.2.1.4.2.1(Corrosion resistance of perforation resistant metallic insert for Class I footwear and hybrid mounted footwear) |
- |
53900 |
|
- |
Cl 6.2.1.4.2.2(Corrosion resistance of perforation resistant metallic insert for Class II footwear and hybrid moulded footwear) |
- |
53900 |
|
- |
Cl 6.2.1.4.3(Stability against ageing and environmental influence of non-metallic perforationresistant inserts) |
- |
53900 |
|
- |
Cl 6.2.2.1(Electrical properties of Partially conductive footwear) |
- |
53900 |
|
- |
Cl 6.2.2.2(Electrical properties of Antistatic footwear) |
- |
53900 |
|
- |
Cl 6.2.3.1(Heat insulation of outsole complex) |
- |
53900 |
|
- |
Cl 6.2.3.2(Cold insulation of outsole complex) |
- |
53900 |
|
- |
Cl 6.2.4(Energy absorption of seat region) |
- |
53900 |
|
- |
Cl 6.2.5(Water resistance) |
- |
53900 |
|
- |
Cl 6.2.6.1(Metatarsal protection - Construction) |
- |
53900 |
|
- |
Cl 6.2.6.2("Metatarsal protection-Impact resistance of metatarsal protective device
") |
- |
53900 |
|
- |
Cl 6.2.7(Ankle protection) |
- |
53900 |
|
- |
Cl 6.2.8.2(Cut resistance footwear- design) |
- |
53900 |
|
- |
Cl 6.2.8.2(Dimensions and construction of protective area of Cut resistance footwear) |
- |
53900 |
|
- |
Cl 6.2.8.3(Resistance to cutting) |
- |
53900 |
|
- |
Cl 6.2.9(Scuff cap) |
- |
53900 |
|
- |
Cl 6.2.10("Slip resistance on ceramic tile floor with glycerine
") |
- |
53900 |
|
- |
Cl 6.3(Upper — Water penetration and absorption) |
- |
53900 |
|
- |
Cl 6.4.1(Resistance to hot contact - Outsole) |
- |
53900 |
|
- |
Cl 6.4.2(Resistance to fuel oil - Outsole) |
- |
53900 |
|
- |
Cl 6.4.3.1(Mechanical properties of Ladder grip) |
- |
53900 |
|
- |
Cl 6.4.3.2(Design of Ladder grip) |
- |
53900 |
|
- |
Cl 6.4.3.3(Cleat height in the waist area of Ladder grip) |
- |
53900 |
|
- |
Cl 6.4.3.4(Heel breast of Ladder grip) |
- |
53900 |
|
- |
Cl 7("Marking
") |
- |
53900 |
|
- |
Cl 7("Marking
") |
- |
53900 |
|
- |
|
25 Feb, 2027 |
- Included w.e.f 13.03.2025 |
19 |
IS 15298 : Part 2 (2024) |
Personal Protective Equipment Part 2 Safety Footwear (ISO 20345 : 2021, MOD) (Third Revision) |
- |
53900 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Cl 5.2(Design) |
- |
53900 |
|
- |
Cl 5.2.2, Table 4(" Height of upper
") |
- |
53900 |
|
- |
Cl 5.2.3(Heel area) |
- |
53900 |
|
- |
Cl 5.3.1.1(Construction of whole footwear) |
- |
53900 |
|
- |
Cl 5.3.1.2(Upper/outsole bond strength) |
- |
53900 |
|
- |
Cl 5.3.2.1(Toe protection - general) |
- |
53900 |
|
- |
Cl 5.3.2.2(Internal length) |
- |
53900 |
|
- |
Cl 5.3.2.3(Width of toecap flange) |
- |
53900 |
|
- |
Cl 5.3.2.4.1(Corrosion resistance of Class I footwear and hybrid mounted footwear) |
- |
53900 |
|
- |
Cl 5.3.2.4.2(Corrosion resistance of Class II and hybrid moulded footwear) |
- |
53900 |
|
- |
Cl 5.3.2.5(Behaviour of toecaps (thermal and chemical) of Corrosion resistance) |
- |
53900 |
|
- |
Cl 5.3.2.6(Impact resistance) |
- |
53900 |
|
- |
Cl 5.3.2.7(Compression resistance) |
- |
53900 |
|
- |
Cl 5.3.3(Leak proofness) |
- |
53900 |
|
- |
Cl 5.3.4("Specific ergonomic features
") |
- |
53900 |
|
- |
Cl 5.3.5.2, Table 7(Slip resistance on ceramic tile floor with sodium lauryl sulphate (NaLS) solution) |
- |
53900 |
|
- |
Cl 5.3.6, Table no 1 of IS 17011,(i)(Allergenic and carcinogenic disperse dyes) |
- |
53900 |
|
- |
Cl 5.3.6, Table no 1 of IS 17011 (ii)(Aromatic amines released from Azo dyes (each individual amine)) |
- |
53900 |
|
- |
Cl 5.3.6, Table no 1 of IS 17011 (iii)(Aromatic amines released from Azo dyes (each individual amine)) |
- |
53900 |
|
- |
Cl 5.3.6, Table no 1 of IS 17011 (iv)(Chromium (VI)) |
- |
53900 |
|
- |
Cl 5.3.6, Table no 1 of IS 17011 (v)(Dimethyl fumarate (DMFU)) |
- |
53900 |
|
- |
Cl 5.3.6, Table no1 of IS 17011 (vi)(Formaldehyde (free or released by partial hydrolysis)) |
- |
53900 |
|
- |
Cl 5.3.6, Table no 1 of IS 17011 (vii)(Formaldehyde) |
- |
53900 |
|
- |
Cl 5.3.6, Table no 1 of IS 17011 (viii)(Organotin compounds) |
- |
53900 |
|
- |
Cl 5.3.6, Table no 1 of IS 17011 (ix)(PCP-TeCP-TriCP polychlorophenols) |
- |
53900 |
|
- |
Cl 5.3.6, Table no 1 of IS 17011 (x)(pH) |
- |
53900 |
|
- |
Cl 5.3.6, Table no 1 of IS 17011 (xi)(Phthalates (each individual phthalate)) |
- |
53900 |
|
- |
Cl 5.3.6, Table no 1 of IS 17011 (xii)(Nickel, on skin contact) |
- |
53900 |
|
- |
Cl 5.3.7(Seam strength) |
- |
53900 |
|
- |
Cl 5.3.8(Lead Content ( National Annex A)) |
- |
53900 |
|
- |
Cl 5.4.1.1(Class I footwear, determination of the area where upper requirements apply of Upper) |
- |
53900 |
|
- |
Cl 5.4.1.2(Hybrid footwear, determination of the area where upper requirements apply of Upper) |
- |
53900 |
|
- |
Cl 5.4.2(Thickness) |
- |
53900 |
|
- |
Cl 5.4.3(Tear strength) |
- |
53900 |
|
- |
Cl 5.4.4, Table 11(Tensile properties- Tensile strength) |
- |
53900 |
|
- |
Cl 5.4.4, Table 11(Tensile properties- Breaking Force) |
- |
53900 |
|
- |
Cl 5.4.4, Table 11(Tensile properties-Modulus at 100 % elongation) |
- |
53900 |
|
- |
Cl 5.4.4, Table 11(Tensile properties- Elongation at break) |
- |
53900 |
|
- |
Cl 5.4.5(Flexing resistance) |
- |
53900 |
|
- |
Cl 5.4.6(Water vapour permeability and coefficient) |
- |
53900 |
|
- |
Cl 5.4.7(Resistance to hydrolysis) |
- |
53900 |
|
- |
Cl 5.5.2(Lining- Tear strength) |
- |
53900 |
|
- |
Cl 5.5.3(Lining- Abrasion resistance) |
- |
53900 |
|
- |
Cl 5.5.4(Lining-Water vapour permeability and coefficient) |
- |
53900 |
|
- |
Cl 5.6.2, Table 14(Tear strength of tongue) |
- |
53900 |
|
- |
Cl 5.7.1(Thickness of Insole, insock and footbed) |
- |
53900 |
|
- |
Cl 5.7.2(Water permeability of insock) |
- |
53900 |
|
- |
Cl 5.7.3(Water absorption and desorption of Insole, insock and footbed) |
- |
53900 |
|
- |
Cl 5.7.4.1(Abrasion resistance of Insoles) |
- |
53900 |
|
- |
Cl 5.7.4.2(Abrasion resistance of Insocks) |
- |
53900 |
|
- |
Cl 5.8.2.1, Table 15(Thickness of Outsole) |
- |
53900 |
|
- |
Cl 5.8.2.2(Cleated area) |
- |
53900 |
|
- |
Cl 5.8.2.3(Cleat height) |
- |
53900 |
|
- |
Cl 5.8.3(Outsole- Tear strength) |
- |
53900 |
|
- |
Cl 5.8.4(Outsole- Abrasion resistance) |
- |
53900 |
|
- |
Cl 5.8.5(Outsole-Flexing resistance) |
- |
53900 |
|
- |
Cl 5.8.6(Outsole-Resistance to hydrolysis) |
- |
53900 |
|
- |
Cl 5.8.7(Interlayer bond strength) |
- |
53900 |
|
- |
Cl 6.2.1.1.2(Metallic perforation-resistant inserts (Type P)) |
- |
53900 |
|
- |
Cl 6.2.1.1.3(Non-metallic perforation-resistant inserts and insoles (Type PL)) |
- |
53900 |
|
- |
Personal protective equipment: Part 2 safety footwear(Non-metallic perforation-resistant inserts and insoles (Type PS)) |
- |
53900 |
|
- |
Cl 6.2.1.2(Construction of perforation resistant insert) |
- |
53900 |
|
- |
Cl 6.2.1.3(Dimensions of perforation resistant insert) |
- |
53900 |
|
- |
Cl 6.2.1.4.1(Flex resistance of perforation-resistant inserts) |
- |
53900 |
|
- |
Cl 6.2.1.4.2.1(Corrosion resistance of perforation resistant metallic insert for Class I footwear and hybrid mounted footwear) |
- |
53900 |
|
- |
Cl 6.2.1.4.2.2(Corrosion resistance of perforation resistant metallic insert for Class II footwear and hybrid moulded footwear) |
- |
53900 |
|
- |
Cl 6.2.1.4.3(Stability against ageing and environmental influence of non-metallic perforationresistant inserts) |
- |
53900 |
|
- |
Cl 6.2.2.1(Electrical properties of Partially conductive footwear) |
- |
53900 |
|
- |
Cl 6.2.2.2(Electrical properties of Antistatic footwear) |
- |
53900 |
|
- |
Cl 6.2.3.1(Heat insulation of outsole complex) |
- |
53900 |
|
- |
Cl 6.2.3.2(Cold insulation of outsole complex) |
- |
53900 |
|
- |
Cl 6.2.4(Energy absorption of seat region) |
- |
53900 |
|
- |
Cl 6.2.5(Water resistance) |
- |
53900 |
|
- |
Cl 6.2.6.1(Metatarsal protection - Construction) |
- |
53900 |
|
- |
Cl 6.2.6.2("Metatarsal protection-Impact resistance of metatarsal protective device
") |
- |
53900 |
|
- |
Cl 6.2.7(Ankle protection) |
- |
53900 |
|
- |
Cl 6.2.8.2(Cut resistance footwear- design) |
- |
53900 |
|
- |
Cl 6.2.8.2(Dimensions and construction of protective area of Cut resistance footwear) |
- |
53900 |
|
- |
Cl 6.2.8.3(Resistance to cutting) |
- |
53900 |
|
- |
Cl 6.2.9(Scuff cap) |
- |
53900 |
|
- |
Cl 6.2.10 , Table 19("Slip resistance on ceramic tile floor with glycerine
") |
- |
53900 |
|
- |
Cl 6.3(Upper — Water penetration and absorption) |
- |
53900 |
|
- |
Cl 6.4.1(Resistance to hot contact - Outsole) |
- |
53900 |
|
- |
Cl 6.4.2(Resistance to fuel oil - Outsole) |
- |
53900 |
|
- |
Cl 6.4.3.1(Mechanical properties of Ladder grip) |
- |
53900 |
|
- |
Cl 6.4.3.2(Design of Ladder grip) |
- |
53900 |
|
- |
Cl 6.4.3.3(Cleat height in the waist area of Ladder grip) |
- |
53900 |
|
- |
Cl 6.4.3.4(Heel breast of Ladder grip) |
- |
53900 |
|
- |
Cl 7, Table 20("Marking
") |
- |
53900 |
|
- |
Cl 5.2(Design) |
- |
53900 |
|
- |
Cl 5.2.2, Table 4(" Height of upper
") |
- |
53900 |
|
- |
Cl 5.2.3(Heel area) |
- |
53900 |
|
- |
Cl 5.3.1.1(Construction of whole footwear) |
- |
53900 |
|
- |
Cl 5.3.1.2(Upper/outsole bond strength) |
- |
53900 |
|
- |
Cl 5.3.2.1(Toe protection - general) |
- |
53900 |
|
- |
Cl 5.3.2.2(Internal length) |
- |
53900 |
|
- |
Cl 5.3.2.3(Width of toecap flange) |
- |
53900 |
|
- |
Cl 5.3.2.4.1(Corrosion resistance of Class I footwear and hybrid mounted footwear) |
- |
53900 |
|
- |
Cl 5.3.2.4.2(Corrosion resistance of Class II and hybrid moulded footwear) |
- |
53900 |
|
- |
Cl 5.3.2.5(Behaviour of toecaps (thermal and chemical) of Corrosion resistance) |
- |
53900 |
|
- |
Cl 5.3.2.6(Impact resistance) |
- |
53900 |
|
- |
Cl 5.3.2.7(Compression resistance) |
- |
53900 |
|
- |
Cl 5.3.3(Leak proofness) |
- |
53900 |
|
- |
Cl 5.3.4("Specific ergonomic features
") |
- |
53900 |
|
- |
Cl 5.3.5.2, Table 7(Slip resistance on ceramic tile floor with sodium lauryl sulphate (NaLS) solution) |
- |
53900 |
|
- |
Cl 5.3.6, Table no 1 of IS 17011,(i)(Allergenic and carcinogenic disperse dyes) |
- |
53900 |
|
- |
Cl 5.3.6, Table no 1 of IS 17011 (ii)(Aromatic amines released from Azo dyes (each individual amine)) |
- |
53900 |
|
- |
Cl 5.3.6, Table no 1 of IS 17011 (iii)(Aromatic amines released from Azo dyes (each individual amine)) |
- |
53900 |
|
- |
Cl 5.3.6, Table no 1 of IS 17011 (iv)(Chromium (VI)) |
- |
53900 |
|
- |
Cl 5.3.6, Table no 1 of IS 17011 (v)(Dimethyl fumarate (DMFU)) |
- |
53900 |
|
- |
Cl 5.3.6, Table no1 of IS 17011 (vi)(Formaldehyde (free or released by partial hydrolysis)) |
- |
53900 |
|
- |
Cl 5.3.6, Table no 1 of IS 17011 (vii)(Formaldehyde) |
- |
53900 |
|
- |
Cl 5.3.6, Table no 1 of IS 17011 (viii)(Organotin compounds) |
- |
53900 |
|
- |
Cl 5.3.6, Table no 1 of IS 17011 (ix)(PCP-TeCP-TriCP polychlorophenols) |
- |
53900 |
|
- |
Cl 5.3.6, Table no 1 of IS 17011 (x)(pH) |
- |
53900 |
|
- |
Cl 5.3.6, Table no 1 of IS 17011 (xi)(Phthalates (each individual phthalate)) |
- |
53900 |
|
- |
Cl 5.3.6, Table no 1 of IS 17011 (xii)(Nickel, on skin contact) |
- |
53900 |
|
- |
Cl 5.3.7(Seam strength) |
- |
53900 |
|
- |
Cl 5.3.8(Lead Content ( National Annex A)) |
- |
53900 |
|
- |
Cl 5.4.1.1(Class I footwear, determination of the area where upper requirements apply of Upper) |
- |
53900 |
|
- |
Cl 5.4.1.2(Hybrid footwear, determination of the area where upper requirements apply of Upper) |
- |
53900 |
|
- |
Cl 5.4.2(Thickness) |
- |
53900 |
|
- |
Cl 5.4.3(Tear strength) |
- |
53900 |
|
- |
Cl 5.4.4, Table 11(Tensile properties- Tensile strength) |
- |
53900 |
|
- |
Cl 5.4.4, Table 11(Tensile properties- Breaking Force) |
- |
53900 |
|
- |
Cl 5.4.4, Table 11(Tensile properties-Modulus at 100 % elongation) |
- |
53900 |
|
- |
Cl 5.4.4, Table 11(Tensile properties- Elongation at break) |
- |
53900 |
|
- |
Cl 5.4.5(Flexing resistance) |
- |
53900 |
|
- |
Cl 5.4.6(Water vapour permeability and coefficient) |
- |
53900 |
|
- |
Cl 5.4.7(Resistance to hydrolysis) |
- |
53900 |
|
- |
Cl 5.5.2(Lining- Tear strength) |
- |
53900 |
|
- |
Cl 5.5.3(Lining- Abrasion resistance) |
- |
53900 |
|
- |
Cl 5.5.4(Lining-Water vapour permeability and coefficient) |
- |
53900 |
|
- |
Cl 5.6.2, Table 14(Tear strength of tongue) |
- |
53900 |
|
- |
Cl 5.7.1(Thickness of Insole, insock and footbed) |
- |
53900 |
|
- |
Cl 5.7.2(Water permeability of insock) |
- |
53900 |
|
- |
Cl 5.7.3(Water absorption and desorption of Insole, insock and footbed) |
- |
53900 |
|
- |
Cl 5.7.4.1(Abrasion resistance of Insoles) |
- |
53900 |
|
- |
Cl 5.7.4.2(Abrasion resistance of Insocks) |
- |
53900 |
|
- |
Cl 5.8.2.1, Table 15(Thickness of Outsole) |
- |
53900 |
|
- |
Cl 5.8.2.2(Cleated area) |
- |
53900 |
|
- |
Cl 5.8.2.3(Cleat height) |
- |
53900 |
|
- |
Cl 5.8.3(Outsole- Tear strength) |
- |
53900 |
|
- |
Cl 5.8.4(Outsole- Abrasion resistance) |
- |
53900 |
|
- |
Cl 5.8.5(Outsole-Flexing resistance) |
- |
53900 |
|
- |
Cl 5.8.6(Outsole-Resistance to hydrolysis) |
- |
53900 |
|
- |
Cl 5.8.7(Interlayer bond strength) |
- |
53900 |
|
- |
Cl 6.2.1.1.2(Metallic perforation-resistant inserts (Type P)) |
- |
53900 |
|
- |
Cl 6.2.1.1.3(Non-metallic perforation-resistant inserts and insoles (Type PL)) |
- |
53900 |
|
- |
Personal protective equipment: Part 2 safety footwear(Non-metallic perforation-resistant inserts and insoles (Type PS)) |
- |
53900 |
|
- |
Cl 6.2.1.2(Construction of perforation resistant insert) |
- |
53900 |
|
- |
Cl 6.2.1.3(Dimensions of perforation resistant insert) |
- |
53900 |
|
- |
Cl 6.2.1.4.1(Flex resistance of perforation-resistant inserts) |
- |
53900 |
|
- |
Cl 6.2.1.4.2.1(Corrosion resistance of perforation resistant metallic insert for Class I footwear and hybrid mounted footwear) |
- |
53900 |
|
- |
Cl 6.2.1.4.2.2(Corrosion resistance of perforation resistant metallic insert for Class II footwear and hybrid moulded footwear) |
- |
53900 |
|
- |
Cl 6.2.1.4.3(Stability against ageing and environmental influence of non-metallic perforationresistant inserts) |
- |
53900 |
|
- |
Cl 6.2.2.1(Electrical properties of Partially conductive footwear) |
- |
53900 |
|
- |
Cl 6.2.2.2(Electrical properties of Antistatic footwear) |
- |
53900 |
|
- |
Cl 6.2.3.1(Heat insulation of outsole complex) |
- |
53900 |
|
- |
Cl 6.2.3.2(Cold insulation of outsole complex) |
- |
53900 |
|
- |
Cl 6.2.4(Energy absorption of seat region) |
- |
53900 |
|
- |
Cl 6.2.5(Water resistance) |
- |
53900 |
|
- |
Cl 6.2.6.1(Metatarsal protection - Construction) |
- |
53900 |
|
- |
Cl 6.2.6.2("Metatarsal protection-Impact resistance of metatarsal protective device
") |
- |
53900 |
|
- |
Cl 6.2.7(Ankle protection) |
- |
53900 |
|
- |
Cl 6.2.8.2(Cut resistance footwear- design) |
- |
53900 |
|
- |
Cl 6.2.8.2(Dimensions and construction of protective area of Cut resistance footwear) |
- |
53900 |
|
- |
Cl 6.2.8.3(Resistance to cutting) |
- |
53900 |
|
- |
Cl 6.2.9(Scuff cap) |
- |
53900 |
|
- |
Cl 6.2.10 , Table 19("Slip resistance on ceramic tile floor with glycerine
") |
- |
53900 |
|
- |
Cl 6.3(Upper — Water penetration and absorption) |
- |
53900 |
|
- |
Cl 6.4.1(Resistance to hot contact - Outsole) |
- |
53900 |
|
- |
Cl 6.4.2(Resistance to fuel oil - Outsole) |
- |
53900 |
|
- |
Cl 6.4.3.1(Mechanical properties of Ladder grip) |
- |
53900 |
|
- |
Cl 6.4.3.2(Design of Ladder grip) |
- |
53900 |
|
- |
Cl 6.4.3.3(Cleat height in the waist area of Ladder grip) |
- |
53900 |
|
- |
Cl 6.4.3.4(Heel breast of Ladder grip) |
- |
53900 |
|
- |
Cl 7, Table 20("Marking
") |
- |
53900 |
|
- |
Cl 5.2(Design) |
- |
0 |
|
- |
Cl 5.2.2, Table 4(" Height of upper
") |
- |
0 |
|
- |
Cl 5.2.3(Heel area) |
- |
0 |
|
- |
Cl 5.3.1.1(Construction of whole footwear) |
- |
0 |
|
- |
Cl 5.3.1.2(Upper/outsole bond strength) |
- |
0 |
|
- |
Cl 5.3.2.1(Toe protection - general) |
- |
0 |
|
- |
Cl 5.3.2.2(Internal length) |
- |
0 |
|
- |
Cl 5.3.2.3(Width of toecap flange) |
- |
0 |
|
- |
Cl 5.3.2.4.1(Corrosion resistance of Class I footwear and hybrid mounted footwear) |
- |
0 |
|
- |
Cl 5.3.2.4.2(Corrosion resistance of Class II and hybrid moulded footwear) |
- |
0 |
|
- |
Cl 5.3.2.5(Behaviour of toecaps (thermal and chemical) of Corrosion resistance) |
- |
0 |
|
- |
Cl 5.3.2.6(Impact resistance) |
- |
0 |
|
- |
Cl 5.3.2.7(Compression resistance) |
- |
0 |
|
- |
Cl 5.3.3(Leak proofness) |
- |
0 |
|
- |
Cl 5.3.4("Specific ergonomic features
") |
- |
0 |
|
- |
Cl 5.3.5.2, Table 7(Slip resistance on ceramic tile floor with sodium lauryl sulphate (NaLS) solution) |
- |
0 |
|
- |
Cl 5.3.6, Table no 1 of IS 17011,(i)(Allergenic and carcinogenic disperse dyes) |
- |
0 |
|
- |
Cl 5.3.6, Table no 1 of IS 17011 (ii)(Aromatic amines released from Azo dyes (each individual amine)) |
- |
0 |
|
- |
Cl 5.3.6, Table no 1 of IS 17011 (iii)(Aromatic amines released from Azo dyes (each individual amine)) |
- |
0 |
|
- |
Cl 5.3.6, Table no 1 of IS 17011 (iv)(Chromium (VI)) |
- |
0 |
|
- |
Cl 5.3.6, Table no 1 of IS 17011 (v)(Dimethyl fumarate (DMFU)) |
- |
0 |
|
- |
Cl 5.3.6, Table no1 of IS 17011 (vi)(Formaldehyde (free or released by partial hydrolysis)) |
- |
0 |
|
- |
Cl 5.3.6, Table no 1 of IS 17011 (vii)(Formaldehyde) |
- |
0 |
|
- |
Cl 5.3.6, Table no 1 of IS 17011 (viii)(Organotin compounds) |
- |
0 |
|
- |
Cl 5.3.6, Table no 1 of IS 17011 (ix)(PCP-TeCP-TriCP polychlorophenols) |
- |
0 |
|
- |
Cl 5.3.6, Table no 1 of IS 17011 (x)(pH) |
- |
0 |
|
- |
Cl 5.3.6, Table no 1 of IS 17011 (xi)(Phthalates (each individual phthalate)) |
- |
0 |
|
- |
Cl 5.3.6, Table no 1 of IS 17011 (xii)(Nickel, on skin contact) |
- |
0 |
|
- |
Cl 5.3.7(Seam strength) |
- |
0 |
|
- |
Cl 5.3.8(Lead Content ( National Annex A)) |
- |
0 |
|
- |
Cl 5.4.1.1(Class I footwear, determination of the area where upper requirements apply of Upper) |
- |
0 |
|
- |
Cl 5.4.1.2(Hybrid footwear, determination of the area where upper requirements apply of Upper) |
- |
0 |
|
- |
Cl 5.4.2(Thickness) |
- |
0 |
|
- |
Cl 5.4.3(Tear strength) |
- |
0 |
|
- |
Cl 5.4.4, Table 11(Tensile properties- Tensile strength) |
- |
0 |
|
- |
Cl 5.4.4, Table 11(Tensile properties- Breaking Force) |
- |
0 |
|
- |
Cl 5.4.4, Table 11(Tensile properties-Modulus at 100 % elongation) |
- |
0 |
|
- |
Cl 5.4.4, Table 11(Tensile properties- Elongation at break) |
- |
0 |
|
- |
Cl 5.4.5(Flexing resistance) |
- |
0 |
|
- |
Cl 5.4.6(Water vapour permeability and coefficient) |
- |
0 |
|
- |
Cl 5.4.7(Resistance to hydrolysis) |
- |
0 |
|
- |
Cl 5.5.2(Lining- Tear strength) |
- |
0 |
|
- |
Cl 5.5.3(Lining- Abrasion resistance) |
- |
0 |
|
- |
Cl 5.5.4(Lining-Water vapour permeability and coefficient) |
- |
0 |
|
- |
Cl 5.6.2, Table 14(Tear strength of tongue) |
- |
0 |
|
- |
Cl 5.7.1(Thickness of Insole, insock and footbed) |
- |
0 |
|
- |
Cl 5.7.2(Water permeability of insock) |
- |
0 |
|
- |
Cl 5.7.3(Water absorption and desorption of Insole, insock and footbed) |
- |
0 |
|
- |
Cl 5.7.4.1(Abrasion resistance of Insoles) |
- |
0 |
|
- |
Cl 5.7.4.2(Abrasion resistance of Insocks) |
- |
0 |
|
- |
Cl 5.8.2.1, Table 15(Thickness of Outsole) |
- |
0 |
|
- |
Cl 5.8.2.2(Cleated area) |
- |
0 |
|
- |
Cl 5.8.2.3(Cleat height) |
- |
0 |
|
- |
Cl 5.8.3(Outsole- Tear strength) |
- |
0 |
|
- |
Cl 5.8.4(Outsole- Abrasion resistance) |
- |
0 |
|
- |
Cl 5.8.5(Outsole-Flexing resistance) |
- |
0 |
|
- |
Cl 5.8.6(Outsole-Resistance to hydrolysis) |
- |
0 |
|
- |
Cl 5.8.7(Interlayer bond strength) |
- |
0 |
|
- |
Cl 6.2.1.1.2(Metallic perforation-resistant inserts (Type P)) |
- |
0 |
|
- |
Cl 6.2.1.1.3(Non-metallic perforation-resistant inserts and insoles (Type PL)) |
- |
0 |
|
- |
Personal protective equipment: Part 2 safety footwear(Non-metallic perforation-resistant inserts and insoles (Type PS)) |
- |
0 |
|
- |
Cl 6.2.1.2(Construction of perforation resistant insert) |
- |
0 |
|
- |
Cl 6.2.1.3(Dimensions of perforation resistant insert) |
- |
0 |
|
- |
Cl 6.2.1.4.1(Flex resistance of perforation-resistant inserts) |
- |
0 |
|
- |
Cl 6.2.1.4.2.1(Corrosion resistance of perforation resistant metallic insert for Class I footwear and hybrid mounted footwear) |
- |
0 |
|
- |
Cl 6.2.1.4.2.2(Corrosion resistance of perforation resistant metallic insert for Class II footwear and hybrid moulded footwear) |
- |
0 |
|
- |
Cl 6.2.1.4.3(Stability against ageing and environmental influence of non-metallic perforationresistant inserts) |
- |
0 |
|
- |
Cl 6.2.2.1(Electrical properties of Partially conductive footwear) |
- |
0 |
|
- |
Cl 6.2.2.2(Electrical properties of Antistatic footwear) |
- |
0 |
|
- |
Cl 6.2.3.1(Heat insulation of outsole complex) |
- |
0 |
|
- |
Cl 6.2.3.2(Cold insulation of outsole complex) |
- |
0 |
|
- |
Cl 6.2.4(Energy absorption of seat region) |
- |
0 |
|
- |
Cl 6.2.5(Water resistance) |
- |
0 |
|
- |
Cl 6.2.6.1(Metatarsal protection - Construction) |
- |
0 |
|
- |
Cl 6.2.6.2("Metatarsal protection-Impact resistance of metatarsal protective device
") |
- |
0 |
|
- |
Cl 6.2.7(Ankle protection) |
- |
0 |
|
- |
Cl 6.2.8.2(Cut resistance footwear- design) |
- |
0 |
|
- |
Cl 6.2.8.2(Dimensions and construction of protective area of Cut resistance footwear) |
- |
0 |
|
- |
Cl 6.2.8.3(Resistance to cutting) |
- |
0 |
|
- |
Cl 6.2.9(Scuff cap) |
- |
0 |
|
- |
Cl 6.2.10 , Table 19("Slip resistance on ceramic tile floor with glycerine
") |
- |
0 |
|
- |
Cl 6.3(Upper — Water penetration and absorption) |
- |
0 |
|
- |
Cl 6.4.1(Resistance to hot contact - Outsole) |
- |
0 |
|
- |
Cl 6.4.2(Resistance to fuel oil - Outsole) |
- |
0 |
|
- |
Cl 6.4.3.1(Mechanical properties of Ladder grip) |
- |
0 |
|
- |
Cl 6.4.3.2(Design of Ladder grip) |
- |
0 |
|
- |
Cl 6.4.3.3(Cleat height in the waist area of Ladder grip) |
- |
0 |
|
- |
Cl 6.4.3.4(Heel breast of Ladder grip) |
- |
0 |
|
- |
Cl 7, Table 20("Marking
") |
- |
0 |
|
- |
Cl 5.2(Design) |
- |
- |
|
- |
Cl 5.2.2, Table 4(" Height of upper
") |
- |
- |
|
- |
Cl 5.2.3(Heel area) |
- |
- |
|
- |
Cl 5.3.1.1(Construction of whole footwear) |
- |
- |
|
- |
Cl 5.3.1.2(Upper/outsole bond strength) |
- |
- |
|
- |
Cl 5.3.2.1(Toe protection - general) |
- |
- |
|
- |
Cl 5.3.2.2(Internal length) |
- |
- |
|
- |
Cl 5.3.2.3(Width of toecap flange) |
- |
- |
|
- |
Cl 5.3.2.4.1(Corrosion resistance of Class I footwear and hybrid mounted footwear) |
- |
- |
|
- |
Cl 5.3.2.4.2(Corrosion resistance of Class II and hybrid moulded footwear) |
- |
- |
|
- |
Cl 5.3.2.5(Behaviour of toecaps (thermal and chemical) of Corrosion resistance) |
- |
- |
|
- |
Cl 5.3.2.6(Impact resistance) |
- |
- |
|
- |
Cl 5.3.2.7(Compression resistance) |
- |
- |
|
- |
Cl 5.3.3(Leak proofness) |
- |
- |
|
- |
Cl 5.3.4("Specific ergonomic features
") |
- |
- |
|
- |
Cl 5.3.5.2, Table 7(Slip resistance on ceramic tile floor with sodium lauryl sulphate (NaLS) solution) |
- |
- |
|
- |
Cl 5.3.6, Table no 1 of IS 17011,(i)(Allergenic and carcinogenic disperse dyes) |
- |
- |
|
- |
Cl 5.3.6, Table no 1 of IS 17011 (ii)(Aromatic amines released from Azo dyes (each individual amine)) |
- |
- |
|
- |
Cl 5.3.6, Table no 1 of IS 17011 (iii)(Aromatic amines released from Azo dyes (each individual amine)) |
- |
- |
|
- |
Cl 5.3.6, Table no 1 of IS 17011 (iv)(Chromium (VI)) |
- |
- |
|
- |
Cl 5.3.6, Table no 1 of IS 17011 (v)(Dimethyl fumarate (DMFU)) |
- |
- |
|
- |
Cl 5.3.6, Table no1 of IS 17011 (vi)(Formaldehyde (free or released by partial hydrolysis)) |
- |
- |
|
- |
Cl 5.3.6, Table no 1 of IS 17011 (vii)(Formaldehyde) |
- |
- |
|
- |
Cl 5.3.6, Table no 1 of IS 17011 (viii)(Organotin compounds) |
- |
- |
|
- |
Cl 5.3.6, Table no 1 of IS 17011 (ix)(PCP-TeCP-TriCP polychlorophenols) |
- |
- |
|
- |
Cl 5.3.6, Table no 1 of IS 17011 (x)(pH) |
- |
- |
|
- |
Cl 5.3.6, Table no 1 of IS 17011 (xi)(Phthalates (each individual phthalate)) |
- |
- |
|
- |
Cl 5.3.6, Table no 1 of IS 17011 (xii)(Nickel, on skin contact) |
- |
- |
|
- |
Cl 5.3.7(Seam strength) |
- |
- |
|
- |
Cl 5.3.8(Lead Content ( National Annex A)) |
- |
- |
|
- |
Cl 5.4.1.1(Class I footwear, determination of the area where upper requirements apply of Upper) |
- |
- |
|
- |
Cl 5.4.1.2(Hybrid footwear, determination of the area where upper requirements apply of Upper) |
- |
- |
|
- |
Cl 5.4.2(Thickness) |
- |
- |
|
- |
Cl 5.4.3(Tear strength) |
- |
- |
|
- |
Cl 5.4.4, Table 11(Tensile properties- Tensile strength) |
- |
- |
|
- |
Cl 5.4.4, Table 11(Tensile properties- Breaking Force) |
- |
- |
|
- |
Cl 5.4.4, Table 11(Tensile properties-Modulus at 100 % elongation) |
- |
- |
|
- |
Cl 5.4.4, Table 11(Tensile properties- Elongation at break) |
- |
- |
|
- |
Cl 5.4.5(Flexing resistance) |
- |
- |
|
- |
Cl 5.4.6(Water vapour permeability and coefficient) |
- |
- |
|
- |
Cl 5.4.7(Resistance to hydrolysis) |
- |
- |
|
- |
Cl 5.5.2(Lining- Tear strength) |
- |
- |
|
- |
Cl 5.5.3(Lining- Abrasion resistance) |
- |
- |
|
- |
Cl 5.5.4(Lining-Water vapour permeability and coefficient) |
- |
- |
|
- |
Cl 5.6.2, Table 14(Tear strength of tongue) |
- |
- |
|
- |
Cl 5.7.1(Thickness of Insole, insock and footbed) |
- |
- |
|
- |
Cl 5.7.2(Water permeability of insock) |
- |
- |
|
- |
Cl 5.7.3(Water absorption and desorption of Insole, insock and footbed) |
- |
- |
|
- |
Cl 5.7.4.1(Abrasion resistance of Insoles) |
- |
- |
|
- |
Cl 5.7.4.2(Abrasion resistance of Insocks) |
- |
- |
|
- |
Cl 5.8.2.1, Table 15(Thickness of Outsole) |
- |
- |
|
- |
Cl 5.8.2.2(Cleated area) |
- |
- |
|
- |
Cl 5.8.2.3(Cleat height) |
- |
- |
|
- |
Cl 5.8.3(Outsole- Tear strength) |
- |
- |
|
- |
Cl 5.8.4(Outsole- Abrasion resistance) |
- |
- |
|
- |
Cl 5.8.5(Outsole-Flexing resistance) |
- |
- |
|
- |
Cl 5.8.6(Outsole-Resistance to hydrolysis) |
- |
- |
|
- |
Cl 5.8.7(Interlayer bond strength) |
- |
- |
|
- |
Cl 6.2.1.1.2(Metallic perforation-resistant inserts (Type P)) |
- |
- |
|
- |
Cl 6.2.1.1.3(Non-metallic perforation-resistant inserts and insoles (Type PL)) |
- |
- |
|
- |
Personal protective equipment: Part 2 safety footwear(Non-metallic perforation-resistant inserts and insoles (Type PS)) |
- |
- |
|
- |
Cl 6.2.1.2(Construction of perforation resistant insert) |
- |
- |
|
- |
Cl 6.2.1.3(Dimensions of perforation resistant insert) |
- |
- |
|
- |
Cl 6.2.1.4.1(Flex resistance of perforation-resistant inserts) |
- |
- |
|
- |
Cl 6.2.1.4.2.1(Corrosion resistance of perforation resistant metallic insert for Class I footwear and hybrid mounted footwear) |
- |
- |
|
- |
Cl 6.2.1.4.2.2(Corrosion resistance of perforation resistant metallic insert for Class II footwear and hybrid moulded footwear) |
- |
- |
|
- |
Cl 6.2.1.4.3(Stability against ageing and environmental influence of non-metallic perforationresistant inserts) |
- |
- |
|
- |
Cl 6.2.2.1(Electrical properties of Partially conductive footwear) |
- |
- |
|
- |
Cl 6.2.2.2(Electrical properties of Antistatic footwear) |
- |
- |
|
- |
Cl 6.2.3.1(Heat insulation of outsole complex) |
- |
- |
|
- |
Cl 6.2.3.2(Cold insulation of outsole complex) |
- |
- |
|
- |
Cl 6.2.4(Energy absorption of seat region) |
- |
- |
|
- |
Cl 6.2.5(Water resistance) |
- |
- |
|
- |
Cl 6.2.6.1(Metatarsal protection - Construction) |
- |
- |
|
- |
Cl 6.2.6.2("Metatarsal protection-Impact resistance of metatarsal protective device
") |
- |
- |
|
- |
Cl 6.2.7(Ankle protection) |
- |
- |
|
- |
Cl 6.2.8.2(Cut resistance footwear- design) |
- |
- |
|
- |
Cl 6.2.8.2(Dimensions and construction of protective area of Cut resistance footwear) |
- |
- |
|
- |
Cl 6.2.8.3(Resistance to cutting) |
- |
- |
|
- |
Cl 6.2.9(Scuff cap) |
- |
- |
|
- |
Cl 6.2.10 , Table 19("Slip resistance on ceramic tile floor with glycerine
") |
- |
- |
|
- |
Cl 6.3(Upper — Water penetration and absorption) |
- |
- |
|
- |
Cl 6.4.1(Resistance to hot contact - Outsole) |
- |
- |
|
- |
Cl 6.4.2(Resistance to fuel oil - Outsole) |
- |
- |
|
- |
Cl 6.4.3.1(Mechanical properties of Ladder grip) |
- |
- |
|
- |
Cl 6.4.3.2(Design of Ladder grip) |
- |
- |
|
- |
Cl 6.4.3.3(Cleat height in the waist area of Ladder grip) |
- |
- |
|
- |
Cl 6.4.3.4(Heel breast of Ladder grip) |
- |
- |
|
- |
Cl 7, Table 20("Marking
") |
- |
- |
|
- |
|
25 Feb, 2027 |
- Included w.e.f 13.03.2025 |
20 |
IS 17634 (2022) |
Storage Units - Specification |
- |
94500 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
CLAUSE 5(DIMENSIONS) |
- |
0 |
|
- |
CLAUSE 6.2(Fabric and Leather (Synthetic and Natural) Performance) |
- |
0 |
|
- |
CLAUSE 6(SURFACE PERFORMANCE) |
- |
0 |
|
- |
CLAUSE 7.1(SAFETY TESTS (General)) |
- |
0 |
|
- |
CLAUSE 7.2(Test for Non-Movable Parts) |
- |
0 |
|
- |
CLAUSE 7.2.1(Shelves) |
- |
0 |
|
- |
CLAUSE 7.2.1.2(Deflection of shelves) |
- |
0 |
|
- |
CLAUSE 7.2.2.1(Sustained load test for tops and bottoms) |
- |
0 |
|
- |
CLAUSE 7.2.2.2(Static load test for tops and bottoms) |
- |
0 |
|
- |
CLAUSE 7.2.3.1(Strength of clothes-rail supports) |
- |
0 |
|
- |
CLAUSE 7.2.3.2(Dislodgement of clothes rail) |
- |
0 |
|
- |
CLAUSE 7.2.4.2(Drop test) |
- |
0 |
|
- |
CLAUSE 7.2.4.3(Tests for units with castors or wheels) |
- |
0 |
|
- |
CLAUSE 7.3.1(Pivoted Doors) |
- |
0 |
|
- |
CLAUSE 7.3.1.2.1(Vertical load on pivoted door) |
- |
0 |
|
- |
CLAUSE 7.3.1.2.2(Horizontal load on pivoted door) |
- |
0 |
|
- |
CLAUSE 7.3.1.3(Slam-shut test of pivoted doors) |
- |
0 |
|
- |
CLAUSE 7.3.1.4(Durability of pivoted doors) |
- |
0 |
|
- |
Cl-6.1 (a)(Resistance to mechanical damage) |
- |
0 |
|
- |
Cl-6.1 (b)(Pencil hardness) |
- |
0 |
|
- |
Cl-6.1 (c)(Resistance to wet heat) |
- |
0 |
|
- |
Cl-6.1 (d)Cl-6.1 (d)(Resistance to dry heat) |
- |
0 |
|
- |
Cl-6.1 (e)(Resistance to marking by cold liquids) |
- |
0 |
|
- |
Cl-6.1 (f)(Resistance to marking by cold oils and fats
Resistance to marking by cold oils and fats) |
- |
0 |
|
- |
Cl-6.1 (g)(Adhesive performance) |
- |
0 |
|
- |
Cl-6.2 (a) 1(Breaking load) |
- |
0 |
|
- |
Cl-6.2 (a) 2(Elongation at break) |
- |
0 |
|
- |
Cl-6.2 (a) 3(Tear strength) |
- |
0 |
|
- |
Cl-6.2 (a) 4(Colour fastness to light) |
- |
0 |
|
- |
Cl-6.2 (a) 5(Colour fastness to rubbing) |
- |
0 |
|
- |
Cl-6.2 (a) 6(Colour fastness to perspiration) |
- |
0 |
|
- |
Cl-6.2 (a) 7(Colour fastness to water) |
- |
0 |
|
- |
Cl-6.2 (a) 8(Pilling resistance) |
- |
0 |
|
- |
Cl-6.2 (a) 9(Coating adhesion strength) |
- |
0 |
|
- |
Cl-6.2 (a) 10(Seam slippage) |
- |
0 |
|
- |
Cl-6.2 (a) 11(Resistance to damage by flexing) |
- |
0 |
|
- |
Cl-6.2 (a) 12(Abrasion resistance) |
- |
0 |
|
- |
Cl-6.2 (a) 13(Bursting strength) |
- |
0 |
|
- |
Cl-6.2 (a) 14(Resistance to cold) |
- |
0 |
|
- |
Cl-6.2 (b) 1(Tear strength) |
- |
0 |
|
- |
Cl-6.2 (b) 2(Flexing endurance) |
- |
0 |
|
- |
Cl-6.2 (b) 3(Finish adhesion) |
- |
0 |
|
- |
Cl-6.2 (b) 4(Colour fastness to artificial light) |
- |
0 |
|
- |
Cl-6.2 (b) 5(Colour fastness to rubbing) |
- |
0 |
|
- |
Cl-6.2 (b) 6(Colour fastness to water spotting) |
- |
0 |
|
- |
Cl-6.2 (b) 7(Water vapour permeability) |
- |
0 |
|
- |
Cl-6.2 (b) 8(Colour fastness to water) |
- |
0 |
|
- |
Cl-7.1(General) |
- |
0 |
|
- |
Cl-7.2.1(Shelves) |
- |
0 |
|
- |
Cl-7.2.2(Tops and Bottoms) |
- |
0 |
|
- |
Cl-7.2.3(Strength of Clothes Rails and their Supports) |
- |
0 |
|
- |
Cl-7.2.4(Strength of the Structure) |
- |
0 |
|
- |
Cl-7.3.1(Pivoted Doors) |
- |
0 |
|
- |
Cl-7.3.2(Sliding Doors and Horizontal Roll-fronts) |
- |
0 |
|
- |
Cl-7.3.3(Flaps) |
- |
0 |
|
- |
Cl-7.3.4(Vertical Roll-Fronts) |
- |
0 |
|
- |
Cl-7.3.5(Extension Elements) |
- |
0 |
|
- |
Cl-7.3.6(Locking and Latching Mechanism Test) |
- |
0 |
|
- |
Cl-7.3.7(Pull Force Test) |
- |
0 |
|
- |
Cl-7.3.8(Top Load Ease Cycle Test) |
- |
0 |
|
- |
Cl-7.3.9(Durability Test for Units with Seating Surfaces – Cyclic Impact) |
- |
0 |
|
- |
Cl-7.3.10(Drop Test – Dynamic – for Units with Seat Surfaces) |
- |
0 |
|
- |
Cl-7.4.1(Units Not Supported by the Floor) |
- |
0 |
|
- |
Cl-7.4.2(Units Supported by the Floor) |
- |
0 |
|
- |
Cl-7.5.1(General) |
- |
0 |
|
- |
Cl-7.5.2(Doors, Extension Elements and Flaps Closed, All Storage Units Unloaded) |
- |
0 |
|
- |
Cl-7.5.3(Opening Doors, Extension Elements and Flaps, All Storage Units Unloaded) |
- |
0 |
|
- |
Cl-7.5.4(Doors, Extension Elements and Flaps Opened and Unlocked) |
- |
0 |
|
- |
Cl-7.5.5(Doors, Extension Elements and Flaps Closed and Locked, All Storage Units Loaded) |
- |
0 |
|
- |
Cl-7.5.6(Vertical Force Stability Test for Storage Units) |
- |
0 |
|
- |
Cl-7.5.7(Stability Test for Pedestals/Storage Units with Seat Surfaces) |
- |
0 |
|
- |
Cl-7.5.8(Dynamic Stability Test for Units with Castors) |
- |
0 |
|
- |
Cl-7.5.9(Strength Test for Wall Attachments) |
- |
0 |
|
- |
Cl-9(Marking) |
- |
0 |
|
- |
CLAUSE 7.3.2(Sliding Doors and Horizontal Roll-fronts) |
- |
0 |
|
- |
CLAUSE 7.3.2.2(Slam shut/open test of sliding doors and horizontal roll-fronts) |
- |
0 |
|
- |
CLAUSE 7.3.2.3(Durability of sliding doors and horizontal roll-fronts) |
- |
0 |
|
- |
CLAUSE 7.3.3(Flaps) |
- |
0 |
|
- |
CLAUSE 7.3.3.1(Strength of bottom-hinged flaps) |
- |
0 |
|
- |
CLAUSE 7.3.3.2(Durability of flaps) |
- |
0 |
|
- |
CLAUSE 7.3.3.3(Drop test for top-hinged flaps) |
- |
0 |
|
- |
CLAUSE 7.3.4(Vertical Roll-Fronts) |
- |
0 |
|
- |
CLAUSE 7.3.4.1(Slam shut/open test of vertical roll-fronts) |
- |
0 |
|
- |
CLAUSE 7.3.4.2(Durability of vertical roll-fronts) |
- |
0 |
|
- |
CLAUSE 7.3.5(Extension Element) |
- |
0 |
|
- |
CLAUSE 7.3.5.2(Strength of extension elements) |
- |
0 |
|
- |
CLAUSE 7.3.5.3(Durability of extension elements) |
- |
0 |
|
- |
CLAUSE 7.3.5.4(Slam shut/open test of extension element) |
- |
0 |
|
- |
CLAUSE 7.3.5.5(Displacement of extension element bottoms) |
- |
0 |
|
- |
CLAUSE 7.3.5.6(Interlock test) |
- |
0 |
|
- |
CLAUSE 7.3.6(Locking and Latching Mechanism Tests) |
- |
0 |
|
- |
CLAUSE 7.3.6.2(Strength test for locking and latching mechanisms for extension elements) |
- |
0 |
|
- |
CLAUSE 7.3.6.3(Locking and latching mechanisms for doors, flaps and roll-fronts) |
- |
0 |
|
- |
CLAUSE 7.3.6.4(Durability test of locking and latching mechanisms) |
- |
0 |
|
- |
CLAUSE 7.3.7(Pull Force Test) |
- |
0 |
|
- |
CLAUSE 7.3.7(Pull Force Test) |
- |
0 |
|
- |
CLAUSE 7.3.8(Top Load Ease Cycle Test) |
- |
0 |
|
- |
CLAUSE 7.3.9(Durability Test for Units with Seating Surfaces – Cyclic Impact) |
- |
0 |
|
- |
CLAUSE 7.3.10("Drop Test – Dynamic – for Units with
Seat Surfaces") |
- |
0 |
|
- |
CLAUSE 7.4.1.3(Sustained load test (overload)) |
- |
0 |
|
- |
CLAUSE 7.4.1.4(Dislodgement test) |
- |
0 |
|
- |
CLAUSE 7.5(Stability Tests) |
- |
0 |
|
- |
CLAUSE 7.5.2.1("Units that can be adjusted to a Height of
1 000 mm or less") |
- |
0 |
|
- |
CLAUSE 7.5.2.2("Units that can be adjusted to a height of
more than 1 000 mm") |
- |
0 |
|
- |
CLAUSE 7.5.3(Opening Doors, Extension Elements and Flaps, All Storage Units Unloaded) |
- |
0 |
|
- |
CLAUSE 7.5.6(Vertical Force Stability Test for Storage Units) |
- |
0 |
|
- |
CLAUSE 7.5.7(Stability Test for Pedestals/Storage Units with Seat Surfaces) |
- |
0 |
|
- |
CLAUSE 7.5.8("Dynamic Stability Test for Units with
Castors") |
- |
0 |
|
- |
CLAUSE 7.5.9(Strength Test for Wall Attachments) |
- |
0 |
|
- |
|
25 Feb, 2027 |
- Included w.e.f 04.06.2025 |
21 |
IS 17633 (2022) |
Tables and Desks - Specification |
- |
30000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
CLAUSE 4(Design and workmanship) |
- |
0 |
|
- |
ClAUSE 5(Dimensions) |
- |
0 |
|
- |
CLAUSE 6(SURFACE PERFORMANCE REQUIRMENTS) |
- |
0 |
|
- |
CLAUSE 7.2.1(Stability Under Vertical Load) |
- |
0 |
|
- |
CLAUSE 7.2.1.1(Test for tables that can be set to a height of 950 mm or less) |
- |
0 |
|
- |
CLAUSE 7.2.1.2(" Test for Tables that can be set to a height greater
than 950 mm") |
- |
0 |
|
- |
CLAUSE 7.2.3(Stability Under Horizontal Load) |
- |
0 |
|
- |
CLAUSE 7.2.3.1(Test for tables that can be set to a height of 950 mm or less) |
- |
0 |
|
- |
CLAUSE 7.2.3.2(" Test for Tables that can be set to a height greater
than 950 mm") |
- |
0 |
|
- |
CLAUSE 7.3.1(Strength under Vertical Static Force) |
- |
0 |
|
- |
CLAUSE 7.3.1.1(Stated load) |
- |
0 |
|
- |
CLAUSE 7.3.1.2(For occasional heavy loads) |
- |
0 |
|
- |
CLAUSE 7.3.2(Strength under horizontal static force) |
- |
0 |
|
- |
CLAUSE 7.4.1(Durability under Vertical Force) |
- |
0 |
|
- |
CLAUSE 7.4.2(Durability of the Height Adjustment Mechanism) |
- |
0 |
|
- |
CLAUSE 7.5.1(Durability and Stiffness Under Horizontal Force) |
- |
0 |
|
- |
CLAUSE 7.5.2(Durability under Horizontal Force) |
- |
0 |
|
- |
CLAUSE 7.5.3(Stiffness of the Structure Under Horizontal Force) |
- |
0 |
|
- |
CLAUSE 7.6.1(Vertical Impact Test) |
- |
0 |
|
- |
CLAUSE 7.6.2(Vertical Impact Test for Glass Table Tops) |
- |
0 |
|
- |
CLAUSE 7.6.3(Vertical Impact Test for All Other Table Tops) |
- |
0 |
|
- |
CLAUSE 7.7(Deflection of Table Tops) |
- |
0 |
|
- |
CLAUSE 7.8(Durability of Tables with Castors) |
- |
0 |
|
- |
CLAUSE 7.9(Drop Test) |
- |
0 |
|
- |
Cl - 5(Dimensions) |
- |
0 |
|
- |
Cl-6 (a)(Resistance to mechanical damage) |
- |
0 |
|
- |
Cl-6 (b)(Pencil hardness) |
- |
0 |
|
- |
Cl-6 (c)(Resistance to wet heat) |
- |
0 |
|
- |
Cl-6 (d)(Resistance to dry heat) |
- |
0 |
|
- |
Cl-6 (e)(Resistance to marking by cold liquids) |
- |
0 |
|
- |
Cl-6 (f)(Resistance to marking by cold oils and fats) |
- |
0 |
|
- |
Cl-6 (g)(Adhesive performance) |
- |
0 |
|
- |
Cl-7.2.1(Stability Under Vertical Load) |
- |
0 |
|
- |
Cl-7.2.2(Stability with Extension Elements Open) |
- |
0 |
|
- |
Cl-7.2.3(Stability Under Horizontal Load) |
- |
0 |
|
- |
Cl-7.3.1(Strength under Vertical Static Force) |
- |
0 |
|
- |
Cl-7.3.2(Strength under horizontal static force) |
- |
0 |
|
- |
Cl-7.4.1(Durability under Vertical Force) |
- |
0 |
|
- |
Cl-7.4.2(Durability of the Height Adjustment Mechanism) |
- |
0 |
|
- |
Cl-7.5.1(General) |
- |
0 |
|
- |
Cl-7.5.2(Durability under Horizontal Force) |
- |
0 |
|
- |
Cl-7.5.3(Stiffness of the Structure Under Horizontal Force) |
- |
0 |
|
- |
Cl-7.6.1(General) |
- |
0 |
|
- |
Cl-7.6.2(Vertical Impact Test for Glass Table Tops) |
- |
0 |
|
- |
Cl-7.6.3(Vertical Impact Test for All Other Table Tops) |
- |
0 |
|
- |
Cl-7.7(Deflection of Table Tops) |
- |
0 |
|
- |
Cl-7.8(Durability of Tables with Castors) |
- |
0 |
|
- |
Cl-7.9(Drop Test) |
- |
0 |
|
- |
Cl-9(Marking) |
- |
0 |
|
- |
7.1(General test conditions) |
- |
0 |
|
- |
CLAUSE 7.2.2(Stability with Extension Elements Open Place the table on the floor surface) |
- |
0 |
|
- |
CLAUSE 4(Design and workmanship) |
- |
0 |
|
- |
ClAUSE 5(Dimensions) |
- |
0 |
|
- |
CLAUSE 6(SURFACE PERFORMANCE REQUIRMENTS) |
- |
0 |
|
- |
CLAUSE 7.2.1(Stability Under Vertical Load) |
- |
0 |
|
- |
CLAUSE 7.2.1.1(Test for tables that can be set to a height of 950 mm or less) |
- |
0 |
|
- |
CLAUSE 7.2.1.2(" Test for Tables that can be set to a height greater
than 950 mm") |
- |
0 |
|
- |
CLAUSE 7.2.3(Stability Under Horizontal Load) |
- |
0 |
|
- |
CLAUSE 7.2.3.1(Test for tables that can be set to a height of 950 mm or less) |
- |
0 |
|
- |
CLAUSE 7.2.3.2(" Test for Tables that can be set to a height greater
than 950 mm") |
- |
0 |
|
- |
CLAUSE 7.3.1(Strength under Vertical Static Force) |
- |
0 |
|
- |
CLAUSE 7.3.1.1(Stated load) |
- |
0 |
|
- |
CLAUSE 7.3.1.2(For occasional heavy loads) |
- |
0 |
|
- |
CLAUSE 7.3.2(Strength under horizontal static force) |
- |
0 |
|
- |
CLAUSE 7.4.1(Durability under Vertical Force) |
- |
0 |
|
- |
CLAUSE 7.4.2(Durability of the Height Adjustment Mechanism) |
- |
0 |
|
- |
CLAUSE 7.5.1(Durability and Stiffness Under Horizontal Force) |
- |
0 |
|
- |
CLAUSE 7.5.2(Durability under Horizontal Force) |
- |
0 |
|
- |
CLAUSE 7.5.3(Stiffness of the Structure Under Horizontal Force) |
- |
0 |
|
- |
CLAUSE 7.6.1(Vertical Impact Test) |
- |
0 |
|
- |
CLAUSE 7.6.2(Vertical Impact Test for Glass Table Tops) |
- |
0 |
|
- |
CLAUSE 7.6.3(Vertical Impact Test for All Other Table Tops) |
- |
0 |
|
- |
CLAUSE 7.7(Deflection of Table Tops) |
- |
0 |
|
- |
CLAUSE 7.8(Durability of Tables with Castors) |
- |
0 |
|
- |
CLAUSE 7.9(Drop Test) |
- |
0 |
|
- |
Cl - 5(Dimensions) |
- |
0 |
|
- |
Cl-6 (a)(Resistance to mechanical damage) |
- |
0 |
|
- |
Cl-6 (b)(Pencil hardness) |
- |
0 |
|
- |
Cl-6 (c)(Resistance to wet heat) |
- |
0 |
|
- |
Cl-6 (d)(Resistance to dry heat) |
- |
0 |
|
- |
Cl-6 (e)(Resistance to marking by cold liquids) |
- |
0 |
|
- |
Cl-6 (f)(Resistance to marking by cold oils and fats) |
- |
0 |
|
- |
Cl-6 (g)(Adhesive performance) |
- |
0 |
|
- |
Cl-7.2.1(Stability Under Vertical Load) |
- |
0 |
|
- |
Cl-7.2.2(Stability with Extension Elements Open) |
- |
0 |
|
- |
Cl-7.2.3(Stability Under Horizontal Load) |
- |
0 |
|
- |
Cl-7.3.1(Strength under Vertical Static Force) |
- |
0 |
|
- |
Cl-7.3.2(Strength under horizontal static force) |
- |
0 |
|
- |
Cl-7.4.1(Durability under Vertical Force) |
- |
0 |
|
- |
Cl-7.4.2(Durability of the Height Adjustment Mechanism) |
- |
0 |
|
- |
Cl-7.5.1(General) |
- |
0 |
|
- |
Cl-7.5.2(Durability under Horizontal Force) |
- |
0 |
|
- |
Cl-7.5.3(Stiffness of the Structure Under Horizontal Force) |
- |
0 |
|
- |
Cl-7.6.1(General) |
- |
0 |
|
- |
Cl-7.6.2(Vertical Impact Test for Glass Table Tops) |
- |
0 |
|
- |
Cl-7.6.3(Vertical Impact Test for All Other Table Tops) |
- |
0 |
|
- |
Cl-7.7(Deflection of Table Tops) |
- |
0 |
|
- |
Cl-7.8(Durability of Tables with Castors) |
- |
0 |
|
- |
Cl-7.9(Drop Test) |
- |
0 |
|
- |
Cl-9(Marking) |
- |
0 |
|
- |
7.1(General test conditions) |
- |
0 |
|
- |
CLAUSE 7.2.2(Stability with Extension Elements Open Place the table on the floor surface) |
- |
0 |
|
- |
|
25 Feb, 2027 |
- Included w.e.f 04.06.2025 |
22 |
IS 17632 (2022) |
General Purpose Chairs and Stools - Specification |
- |
77500 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
CLAUSE 5(DIMENSIONS) |
- |
0 |
|
- |
CLAUSE 6(SURFACE PERFORMANCE) |
- |
0 |
|
- |
CLAUSE 6.2(Fabric and Leather (Synthetic and Natural) Performance) |
- |
0 |
|
- |
CLAUSE 7.2.1(Forwards Overbalancing and Sideways Overbalancing for Chairs without Arms) |
- |
0 |
|
- |
CLAUSE 7.2.2(Rearwards Overbalancing) |
- |
0 |
|
- |
CLAUSE 7.2.3(Sideways Overbalancing for Chairs with Arms) |
- |
0 |
|
- |
CLAUSE 7.2.4(Sideways Overbalancing for Chairs with Arms) |
- |
0 |
|
- |
CLAUSE 7.3.1.1(Seat static load test) |
- |
0 |
|
- |
CLAUSE 7.3.1.2(Back static load test) |
- |
0 |
|
- |
CLAUSE 7.3.1.3(Armrests/Wings sideways static load test) |
- |
0 |
|
- |
CLAUSE 7.3.1.4(Arm downwards static load test) |
- |
0 |
|
- |
CLAUSE 7.3.1.5(Leg forward static load test) |
- |
0 |
|
- |
CLAUSE 7.3.1.6(Leg sideways static load test) |
- |
0 |
|
- |
CLAUSE 7.3.1.7(Diagonal base load test) |
- |
0 |
|
- |
CLAUSE 7.3.1.8(Foot rest static-load test) |
- |
0 |
|
- |
CLAUSE 7.3.2.1(Seat impact test) |
- |
0 |
|
- |
CLAUSE 7.3.2.2(Back impact test) |
- |
0 |
|
- |
CLAUSE 7.3.2.3(Arm impact test) |
- |
0 |
|
- |
CLAUSE 7.3.2.4(Drop test) |
- |
0 |
|
- |
CLAUSE 7.4.1(Seat Fatigue Test) |
- |
0 |
|
- |
CLAUSE 7.4.2(Back Fatigue Test) |
- |
0 |
|
- |
CLAUSE 7.4.3(Arm Rest Durability Test) |
- |
0 |
|
- |
Cl - 5(DIMENSIONS) |
- |
0 |
|
- |
Cl-6.1 (a)(Resistance to mechanical damage) |
- |
0 |
|
- |
Cl-6.1 (b)(Pencil hardness) |
- |
0 |
|
- |
Cl-6.1 (c)(Resistance to wet heat) |
- |
0 |
|
- |
Cl-6.1 (d)(Resistance to dry heat) |
- |
0 |
|
- |
Cl-6.1 (e)(Resistance to marking by cold liquids) |
- |
0 |
|
- |
Cl-6.1 (f)(Resistance to marking by cold oils and fats) |
- |
0 |
|
- |
Cl-6.1 (g)(Adhesive performance) |
- |
0 |
|
- |
Cl-6.2 (a) 1(Breaking load) |
- |
0 |
|
- |
Cl-6.2 (a) 2(Elongation at break) |
- |
0 |
|
- |
Cl-6.2 (a) 3(Tear strength) |
- |
0 |
|
- |
Cl-6.2 (a) 4(Colour fastness to light) |
- |
0 |
|
- |
Cl-6.2 (a) 5(Colour fastness to rubbing) |
- |
0 |
|
- |
Cl-6.2 (a) 6(Colour fastness to perspiration) |
- |
0 |
|
- |
Cl-6.2 (a) 7(Colour fastness to water) |
- |
0 |
|
- |
Cl-6.2 (a) 8(Pilling resistance) |
- |
0 |
|
- |
Cl-6.2 (a) 9(Coating adhesion strength) |
- |
0 |
|
- |
Cl-6.2 (a) 10(Seam slippage) |
- |
0 |
|
- |
Cl-6.2 (a) 11(Resistance to damage by flexing) |
- |
0 |
|
- |
Cl-6.2 (a) 12(Abrasion resistance) |
- |
0 |
|
- |
Cl-6.2 (a) 13(Bursting strength) |
- |
0 |
|
- |
Cl-6.2 (a) 14(Resistance to cold) |
- |
0 |
|
- |
Cl-6.2 (b) 1(Tear strength) |
- |
0 |
|
- |
Cl-6.2 (b) 2(Flexing endurance) |
- |
0 |
|
- |
Cl-6.2 (b) 3(Finish adhesion) |
- |
0 |
|
- |
Cl-6.2 (b) 4(Colour fastness to artificial light) |
- |
0 |
|
- |
Cl-6.2 (b) 5(Colour fastness to rubbing) |
- |
0 |
|
- |
Cl-6.2 (b) 6(Colour fastness to water spotting) |
- |
0 |
|
- |
Cl-6.2 (b) 7(Water vapour permeability) |
- |
0 |
|
- |
Cl-6.2 (b) 8(Colour fastness to water) |
- |
0 |
|
- |
Cl-7.2.1(Forwards Overbalancing and Sideways Overbalancing for Chairs without Arms) |
- |
0 |
|
- |
Cl-7.2.2(Rearwards Overbalancing) |
- |
0 |
|
- |
Cl-7.2.3(Sideways Overbalancing for Chairs with Arms) |
- |
0 |
|
- |
Cl-7.2.4(Stools/ Poufs (All Directions)) |
- |
0 |
|
- |
Cl-7.3.1(Static Load Test) |
- |
0 |
|
- |
Cl-7.3.2(Impact Test) |
- |
0 |
|
- |
Cl-7.4.1(Seat Fatigue Test) |
- |
0 |
|
- |
Cl-7.4.2(Back Fatigue Test) |
- |
0 |
|
- |
Cl-7.4.3(Arm Rest Durability) |
- |
0 |
|
- |
Cl-9(Marking) |
- |
0 |
|
- |
7.1(General test conditions) |
- |
0 |
|
- |
|
25 Feb, 2027 |
- Included w.e.f 04.06.2025 |
23 |
IS 17631 (2022) |
Work Chairs - Specification |
All |
139500 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
clause 4(DESIGN AND WORKMANSHIP) |
- |
0 |
|
- |
clause 5(DIMENSIONS) |
- |
0 |
|
- |
Cl-6.1 (a)(Resistance to mechanical damage) |
- |
0 |
|
- |
Cl-6.2 (a) (1)(For Fabric and Synthetic Leather:- Breaking load) |
- |
0 |
|
- |
Cl-7.3.1(Front Edge Overturning) |
- |
0 |
|
- |
Cl-7.3.2(Forwards Overturning) |
- |
0 |
|
- |
Cl-7.3.3(Forwards Overturning for Chairs with Foot Rest) |
- |
0 |
|
- |
Cl-7.3.4(Sideways Overturning for Chairs Without Arm Rests) |
- |
0 |
|
- |
Cl-6.1 (b)(Pencil hardness) |
- |
0 |
|
- |
Cl-6.1 (c)(Resistance to wet heat;) |
- |
0 |
|
- |
Cl-6.1 (d)(Resistance to dry heat;) |
- |
0 |
|
- |
Cl-6.1 (e)(Resistance to marking by cold liquids) |
- |
0 |
|
- |
Cl-6.1 (f)(Resistance to marking by cold oils and fats;) |
- |
0 |
|
- |
Cl-6.1 (g)(Adhesive performance) |
- |
0 |
|
- |
Cl-6.2 (a) (2)(For Fabric and Synthetic Leather:- Elongation at break) |
- |
0 |
|
- |
Cl-6.2 (a) (3)(For Fabric and Synthetic Leather:- Tear strength) |
- |
0 |
|
- |
Cl-6.2 (a) (4)(For Fabric and Synthetic Leather:- Colour fastness to light) |
- |
0 |
|
- |
Cl-6.2 (a) (5)(For Fabric and Synthetic Leather:- Colour fastness to rubbing) |
- |
0 |
|
- |
Cl-6.2 (a) (6)(For Fabric and Synthetic Leather:- Colour fastness to perspiration) |
- |
0 |
|
- |
Cl-6.2 (a) (7)(For Fabric and Synthetic Leather:- Colour fastness to water) |
- |
0 |
|
- |
Cl-6.2 (a) (8)(For Fabric and Synthetic Leather:- Pilling resistance) |
- |
0 |
|
- |
Cl-6.2 (a) (9)(For Fabric and Synthetic Leather:- Coating adhesion strength) |
- |
0 |
|
- |
Cl-6.2 (a) (10)(For Fabric and Synthetic Leather:- Seam slippage) |
- |
0 |
|
- |
Cl-6.2 (a) (11)(For Fabric and Synthetic Leather:- Resistance to damage by flexing) |
- |
0 |
|
- |
Cl-6.2 (a) (12)(For Fabric and Synthetic Leather:- Abrasion resistance) |
- |
0 |
|
- |
Cl-6.2 (a) (13)(For Fabric and Synthetic Leather:- Bursting strength) |
- |
0 |
|
- |
Cl-6.2 (a) (14)(For Fabric and Synthetic Leather:- Resistance to cold) |
- |
0 |
|
- |
Cl-6.2 (b) (2)(For Natural Leather:- Flexing endurance) |
- |
0 |
|
- |
Cl-6.2 (b) (1)(For Natural Leather:- Tear strength) |
- |
0 |
|
- |
Cl-6.2 (b) (3)(For Natural Leather: Finish adhesion) |
- |
0 |
|
- |
Cl-6.2 (b) (4)(For Natural Leather: Colour fastness to artificial light) |
- |
0 |
|
- |
Cl-6.2 (b) (5)(For Natural Leather: Colour fastness to rubbing) |
- |
0 |
|
- |
Cl-6.2 (b) (6)(For Natural Leather: Colour fastness to water spotting) |
- |
0 |
|
- |
Cl-6.2 (b) (7)(For Natural Leather: Water vapour permeability) |
- |
0 |
|
- |
Cl-6.2 (b) (8)(For Natural Leather: Colour fastness to water) |
- |
0 |
|
- |
Cl-7.3.5(Sideways Overturning for Chairs With Arm Rests) |
- |
0 |
|
- |
Cl-7.3.6(Rearwards Overturning for Chairs Without Back Rest Inclination) |
- |
0 |
|
- |
Cl-7.3.7(Rearwards Overturning for Chairs with Backrest Inclination) |
- |
0 |
|
- |
Cl-7.4.1(Seat Front Edge Static Load Test) |
- |
0 |
|
- |
Cl-7.4.2(Combined Seat and Back Static Load Test) |
- |
0 |
|
- |
Cl-7.4.3(Arm Rest Downward Static Load Test — Central) |
- |
0 |
|
- |
Cl-7.4.4(Arm Rest Downward Static Load Test — Front) |
- |
0 |
|
- |
Cl-7.4.5(Arm Rest Sideways Static Load Test) |
- |
0 |
|
- |
Cl-7.4.6(Foot Rest Static Load Test) |
- |
0 |
|
- |
Cl-7.5.1(Seat and Back Durability) |
- |
0 |
|
- |
Cl-7.5.2(Arm Rest Durability) |
- |
0 |
|
- |
Cl-7.5.3(Swivel Test) |
- |
0 |
|
- |
Cl-7.5.4(Foot-rest Durability) |
- |
0 |
|
- |
Cl-7.5.5(Castor and Chair-Base Durability) |
- |
0 |
|
- |
|
25 Feb, 2027 |
- Included w.e.f 04.06.2025 |
24 |
IS 9550 (2024) |
Bright Steel Bars — Specification |
ALL |
14900 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Cl-4(Supply of material and product designation) |
- |
14900 |
|
- |
Cl-6(Chemical Composition) |
- |
14900 |
|
- |
Cl-7(mechanical properties) |
- |
14900 |
|
- |
Cl-8.1(Dimensions) |
- |
14900 |
|
- |
Cl-8.2.1, Table-1(Cold drawn or heattreated and cold drawn) |
- |
14900 |
|
- |
Cl-8.2.1, Table-1(Cold drawn, heat treated) |
- |
14900 |
|
- |
Cl-8.2.1, Table-1(Peeled/turned) |
- |
14900 |
|
- |
Cl-8.2.1, Table-1(Polished) |
- |
14900 |
|
- |
Cl-8.2.1.1(Tolerances on dimensions) |
- |
14900 |
|
- |
Cl-8.2.2, Table-2 (i)(Manufacturing lengtha) |
- |
14900 |
|
- |
Cl-8.2.2, Table-2 (ii)(Stock lengtha) |
- |
14900 |
|
- |
Cl-8.2.2, Table-2 (iii)(Cut to length) |
- |
14900 |
|
- |
Cl-9(Surface condiotn) |
- |
14900 |
|
- |
Cl-14(Marking) |
- |
14900 |
|
- |
Clause. 6.0(chemical composition) |
- |
14900 |
|
- |
Clause. 6.0(Sillicon) |
- |
14900 |
|
- |
Clause. 6.0(Carbon) |
- |
14900 |
|
- |
Clause. 6.0(Copper) |
- |
14900 |
|
- |
Clause. 6.0(Manganese) |
- |
14900 |
|
- |
Clause. 6.0(Molybdenum) |
- |
14900 |
|
- |
Clause. 6.0(Chromium) |
- |
14900 |
|
- |
Clause. 6.0(Nickel) |
- |
14900 |
|
- |
Clause. 6.0(Sulphur) |
- |
14900 |
|
- |
Clause. 6.0(Phosphorus) |
- |
14900 |
|
- |
Clause. 6.0(Vanadium) |
- |
14900 |
|
- |
Clause. 6.0(Titanium) |
- |
14900 |
|
- |
Clause. 6.0(Boron) |
- |
14900 |
|
- |
Clause. 6.0(Aluminium) |
- |
14900 |
|
- |
Clause. 7.0(Brinell Hardness) |
- |
14900 |
|
- |
Clause. 7.0(Tensile test) |
- |
14900 |
|
- |
Clause. 7.0(Yeild stress) |
- |
14900 |
|
- |
Clause. 7.0(Elongation) |
- |
14900 |
|
- |
Clause. 8.0(Dimension) |
- |
14900 |
|
- |
Clause. 8.0(Tolerence) |
- |
14900 |
|
- |
clause. 9.0(Surface condition) |
- |
14900 |
|
- |
clause. 9.0(Decarburization) |
- |
14900 |
|
- |
clause.-10.0(Sampling) |
- |
14900 |
|
- |
clause.- 11.0(other tests) |
- |
14900 |
|
- |
Clause. -12.0(Retest) |
- |
14900 |
|
- |
Clasue.- 13.0(Surface Protection) |
- |
14900 |
|
- |
Clasue.- 14.0(Marking) |
- |
14900 |
|
- |
|
25 Feb, 2027 |
- - |
25 |
IS 1469 (1993) |
Ferromolybdenum - Specification (Fourth Revision) |
- |
19900 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Clause-6(Supply of Materials) |
- |
0 |
|
- |
Clause-7.1(Constitution of Consignment) |
- |
0 |
|
- |
Clause-8.1(Mo) |
- |
0 |
|
- |
Clause-8.1(C, Max) |
- |
0 |
|
- |
Clause-8.1(Si, Max) |
- |
0 |
|
- |
Clause-8.1(S, Max) |
- |
0 |
|
- |
Clause-8.1(P Max) |
- |
0 |
|
- |
Clause-8.1(Du Max) |
- |
0 |
|
- |
Clause-8.1(Al Max) |
- |
0 |
|
- |
Clause-8.1(Pb Max) |
- |
0 |
|
- |
Clause-8.1(Sn Max) |
- |
0 |
|
- |
Clause-8.4(Established instrumental/chemical method) |
- |
0 |
|
- |
Clause-9(Size Range) |
- |
0 |
|
- |
Clause-12(Marking) |
- |
0 |
|
- |
Clause-6(Supply of Materials) |
- |
0 |
|
- |
Clause-7.1(Constitution of Consignment) |
- |
0 |
|
- |
Clause-8.1(Mo) |
- |
0 |
|
- |
Clause-8.1(C, Max) |
- |
0 |
|
- |
Clause-8.1(Si, Max) |
- |
0 |
|
- |
Clause-8.1(S, Max) |
- |
0 |
|
- |
Clause-8.1(P Max) |
- |
0 |
|
- |
Clause-8.1(Du Max) |
- |
0 |
|
- |
Clause-8.1(Al Max) |
- |
0 |
|
- |
Clause-8.1(Pb Max) |
- |
0 |
|
- |
Clause-8.1(Sn Max) |
- |
0 |
|
- |
Clause-8.4(Established instrumental/chemical method) |
- |
0 |
|
- |
Clause-9(Size Range) |
- |
0 |
|
- |
Clause-12(Marking) |
- |
0 |
|
- |
|
25 Feb, 2027 |
- Included w.e.f. 20.03.2025 |
26 |
IS 1466 (1985) |
Specification for ferrovanadium (Third Revision) |
- |
19900 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Clause-2.1(Ferro Vanadium) |
- |
0 |
|
- |
Clause-3(Grades) |
- |
0 |
|
- |
Clause-5(Chemical Composition) |
- |
0 |
|
- |
Clause-6(Norminal size Ranges) |
- |
0 |
|
- |
Clause-9(Marking) |
- |
0 |
|
- |
3 & 5(V) |
- |
0 |
|
- |
3 & 5(Si) |
- |
0 |
|
- |
3 & 5(C) |
- |
0 |
|
- |
3 & 5(S) |
- |
0 |
|
- |
3 & 5(P) |
- |
0 |
|
- |
3 & 5(Al) |
- |
0 |
|
- |
3 & 5(Mn) |
- |
0 |
|
- |
3 & 5(Cr) |
- |
0 |
|
- |
3 & 5(Cu) |
- |
0 |
|
- |
3 & 5(Ni) |
- |
0 |
|
- |
3 & 5(Pb) |
- |
0 |
|
- |
3 & 5(Sn) |
- |
0 |
|
- |
3 & 5(Zn) |
- |
0 |
|
- |
3 & 5(Mo) |
- |
0 |
|
- |
3 & 5(Ti) |
- |
0 |
|
- |
Clause-4(Supply of Material) |
- |
0 |
|
- |
|
25 Feb, 2027 |
- Included w.e.f. 20.03.2025 |
27 |
IS 18476 (2023) |
Fasteners � Hexagon Washer Head Drilling Screws with Tapping Screw Thread |
- |
19900 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Clause. 4.0(Dimenssions.) |
- |
0 |
|
- |
Clause. 4.0(Thread size.) |
- |
0 |
|
- |
Clause. 4.0(Length) |
- |
0 |
|
- |
Clause. 5.0(Material) |
- |
0 |
|
- |
Clause. 5.0(Thread) |
- |
0 |
|
- |
Clause. 5.0(Tolerances) |
- |
0 |
|
- |
Clause. 5.0(Mechnical and functional properties.) |
- |
0 |
|
- |
Clause. 5.0(Finish) |
- |
0 |
|
- |
Clause. 5.0(Acceptability) |
- |
0 |
|
- |
Clause.6.0(Designation) |
- |
0 |
|
- |
Clause.6.0(Marking) |
- |
0 |
|
- |
|
25 Feb, 2027 |
- Included w.e.f 16.04.2025 |
28 |
IS 18471 : Part 3 (2023) |
Fasteners � Cross Recessed Drilling Screws with Tapping Screw Thread Part 3 Raised Countersunk Head |
- |
19900 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Clause. 3.0(Dimenssions.) |
- |
0 |
|
- |
Clause. 3.0(Thread size.) |
- |
0 |
|
- |
Clause. 3.0(Length) |
- |
0 |
|
- |
Clause. 4.0(Material) |
- |
0 |
|
- |
Clause. 4.0(Thread) |
- |
0 |
|
- |
Clause. 4.0(Cross recesses) |
- |
0 |
|
- |
Clause. 4.0(Tolerances) |
- |
0 |
|
- |
Clause. 4.0(Mechnical and functional properties.) |
- |
0 |
|
- |
Clause. 4.0(Finish) |
- |
0 |
|
- |
Clause. 4.0(Acceptability) |
- |
0 |
|
- |
Clause.5.0(Designation) |
- |
0 |
|
- |
Clause.5.0(Marking) |
- |
0 |
|
- |
|
25 Feb, 2027 |
- Included w.e.f 28.03.2025 |
29 |
IS 18471 : Part 2 (2023) |
Fasteners � Cross Recessed Drilling Screws with Tapping Screw Thread Part 2 Countersunk Head |
- |
19900 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Clause. 3.0(Dimenssions.) |
- |
0 |
|
- |
Clause. 3.0(Thread size.) |
- |
0 |
|
- |
Clause. 3.0(Length) |
- |
0 |
|
- |
Clause. 4.0(Material) |
- |
0 |
|
- |
Clause. 4.0(Thread) |
- |
0 |
|
- |
Clause. 4.0(Cross recesses) |
- |
0 |
|
- |
Clause. 4.0(Mechnical and functional properties.) |
- |
0 |
|
- |
Clause. 4.0(Finish) |
- |
0 |
|
- |
Clause. 4.0(Acceptability) |
- |
0 |
|
- |
Clause.5.0(Designation) |
- |
0 |
|
- |
Clause.5.0(Marking) |
- |
0 |
|
- |
|
25 Feb, 2027 |
- Included w.e.f 28.03.2025 |
30 |
IS 18471 : Part 1 (2023) |
Fasteners � Cross Recessed Drilling Screws with Tapping Screw Thread Part 1 Pan Head |
- |
19900 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Clause. 3.0(Dimenssions.) |
- |
0 |
|
- |
Clause. 3.0(Dimenssions.) |
- |
0 |
|
- |
Clause. 3.0(Thread size.) |
- |
0 |
|
- |
Clause. 3.0(Length) |
- |
0 |
|
- |
Clause. 4.0(Material) |
- |
0 |
|
- |
Clause. 4.0(Thread) |
- |
0 |
|
- |
Clause. 4.0(Cross recesses) |
- |
0 |
|
- |
Clause. 4.0(Mechnical and functional properties.) |
- |
0 |
|
- |
Clause. 4.0(Finish) |
- |
0 |
|
- |
Clause. 4.0(Acceptability) |
- |
0 |
|
- |
Clause.5.0(Designation) |
- |
0 |
|
- |
Clause.5.0(Marking) |
- |
0 |
|
- |
|
25 Feb, 2027 |
- Included w.e.f 28.03.2025 |