61 |
IS 10322 : Part 5 : Sec 5 (2013) |
Luminaires: Part 5 particular requirements: Sec 5 floodlights (First Revision) |
-
|
- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
4 (General Test Requireements) |
- |
|
|
|
5 (Classification of Luminaires') |
- |
|
|
|
6.0 (Marking) |
- |
|
|
|
7.0 (Construction) |
- |
|
|
|
8.0 (Creepage Distance and Clearances) |
- |
|
|
|
9.0 (Provision for earthing) |
- |
|
|
|
10.0 (Terminals) |
- |
|
|
|
11.0 (External & Internal Wiring) |
- |
|
|
|
12.0 (Protection against electric shock) |
- |
|
|
|
13.0 (Endurance Tests and Thermal Tests) |
- |
|
|
|
14.0 (Resistance to Dust & Moisture) |
- |
|
|
|
15.0 (Insulation Resistance and Electric Strength) |
- |
|
|
|
16.0 (Resistance to Heat , fire and tracking) |
- |
|
|
|
|
Partial
|
|
- |
- |
62 |
IS 10322 : PART 5 : SEC 3 (2012) |
Luminaires: Part 5 particular requirements: Sec 3 luminaires for road and street lighting (First Revision) |
-
|
- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
4 (General Test Requireements) |
- |
|
|
|
5 (Classification of Luminaires') |
- |
|
|
|
6.0 (Marking) |
- |
|
|
|
7.0 (Construction) |
- |
|
|
|
8.0 (Creepage Distance and Clearances) |
- |
|
|
|
9.0 (Provision for earthing) |
- |
|
|
|
10.0 (Terminals) |
- |
|
|
|
7.0 (Construction) |
- |
|
|
|
11.0 (External & Internal Wiring) |
- |
|
|
|
12.0 (Protection against electric shock) |
- |
|
|
|
13.0 (Endurance Tests and Thermal Tests) |
- |
|
|
|
14.0 (Resistance to Dust & Moisture) |
- |
|
|
|
15.0 (Insulation Resistance and Electric Strength) |
- |
|
|
|
16.0 (Resistance to Heat , fire and tracking) |
- |
|
|
|
|
Partial
|
|
- |
- |
63 |
IS 10322 : Part 5 : Sec 2 (2012) |
Luminaires: Part 5 particular requirements: Sec 2 recessed luminaires (First Revision) |
-
|
- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
4 (General Test Requireements) |
- |
|
|
|
5 (Classification of Luminaires') |
- |
|
|
|
6 (Marking) |
- |
|
|
|
7 (Construction) |
- |
|
|
|
8 (Creepage Distance and Clearances) |
- |
|
|
|
9 (Provision for earthing) |
- |
|
|
|
10 (Terminals) |
- |
|
|
|
11 (External & Internal Wiring) |
- |
|
|
|
12 (Protection against electric shock) |
- |
|
|
|
13 (Endurance Tests and Thermal Tests) |
- |
|
|
|
14 (Resistance to Dust and Moisture) |
- |
|
|
|
15 (Insulation Resistance and Electric Strength) |
- |
|
|
|
16 (Resistance to Heat , fire and tracking) |
- |
|
|
|
|
Partial
|
|
- |
- |
64 |
IS 10322 : Part 5 : Sec 1 (2012) |
Luminaires: Part 5 particular requirements: Sec 1 fixed general purpose luminaires (First Revision) |
-
|
- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
4 (General Test Requireements) |
- |
|
|
|
5 (Classification of Luminaires') |
- |
|
|
|
6.0 (Marking) |
- |
|
|
|
7.0 (Construction) |
- |
|
|
|
8.0 (Creepage Distance and Clearances) |
- |
|
|
|
9.0 (Provision for earthing) |
- |
|
|
|
10.0 (Terminals) |
- |
|
|
|
11.0 (External & Internal Wiring) |
- |
|
|
|
12.0 (Protection against electric shock) |
- |
|
|
|
13.0 (Endurance Tests and Thermal Tests) |
- |
|
|
|
14.0 (Resistance to Dust & Moisture) |
- |
|
|
|
15.0 (Insulation Resistance and Electric Strength) |
- |
|
|
|
16.0 (Resistance to Heat , fire and tracking) |
- |
|
|
|
|
Partial
|
|
- |
- |
65 |
IS 15885 : Part 2 : Sec 13 (2012) |
Safety of lamp controlgear: Part 2 particular requirements: Sec 13 d.c. or a.c. supplied electronic controlgear for led modules |
-
|
- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
7 (Marking) |
- |
|
|
|
8 (Protection against accidental contact with live parts) |
- |
|
|
|
9 (Terminals) |
- |
|
|
|
10 (PROVISION FOR EARTHING) |
- |
|
|
|
11 (MOISTURE RESISTANCE) |
- |
|
|
|
12 (Electric Strength) |
- |
|
|
|
14 (Fault conditions) |
- |
|
|
|
15 (Transformer heating) |
- |
|
|
|
16 (Construction) |
- |
|
|
|
17 (Creepage distance and clearances) |
- |
|
|
|
18 (Screws, current carrying parts and connections) |
- |
|
|
|
19 (Resistance to heat, fire and tracking) |
- |
|
|
|
20 (Resistance to corrosion) |
- |
|
|
|
|
Partial
|
|
- |
- |
66 |
IS 16102 : Part 1 (2012) |
Self - Ballasted led lamps for general lighting services: Part 1 safety requirements |
-
|
- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
5 (Marking) |
- |
|
|
|
6 (Interchangeability) |
- |
|
|
|
7 (Protection against accidental contact with live parts) |
- |
|
|
|
8 (Insulation Resistance and Electric Strength) |
- |
|
|
|
9 (MECHANICAL STRENGTH) |
- |
|
|
|
10 (cap temperature) |
- |
|
|
|
11 (Resistance to Heat) |
- |
|
|
|
12 (Resistance to Flame and Ignition) |
- |
|
|
|
13 (Fault conditions) |
- |
|
|
|
14 (Creepage distance and clearances) |
- |
|
|
|
|
Partial
|
|
- |
- |
67 |
IS 1374 (2007) |
Poultry feeds - Specification |
-
|
- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
No Record Found
|
|
Partial
|
|
- |
- |
68 |
IS 9825 (2003) |
Chlorine tablets - Specification (Second Revision) |
-
|
- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Cl.4.2 (Description) |
- |
|
|
|
Cl.4.3 (Size (Mass of tablet)) |
- |
|
|
|
Cl.4.3 (Available Chlorine (Annex A)) |
- |
|
|
|
Cl.4.4 (Moisture (Annex B)) |
- |
|
|
|
Cl.4.4 (Shelf Life (Annex A)) |
- |
|
|
|
|
Complete
|
|
- |
- |
69 |
IS 8229 (1986) |
Specification for oil - Well cement (First Revision) |
-
|
- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
4.1 - Table - 1 i (Magnesium Oxide (MgO) - Cl 4.8 of IS 4032:1985) |
- |
|
|
|
4.1 - Table - 1 ii (Sulphur Trioxide(SO3) - Cl 4.9 of IS 4032:1985) |
- |
|
|
|
4.1 - Table - 1 iii (Loss on ignition - Cl 4.2 of IS 4032:1985) |
- |
|
|
|
4.1 - Table - 1 iv (Insoluble residue - Cl 4.10 of IS 4032:1985) |
- |
|
|
|
4.1 - Table - 1 v (Tricalcium aluminate (3CaO.Al2O3) - Cl 4 of IS 4032:1985) |
- |
|
|
|
4.1 - Table - 1 x (Tricalcium Silicate (3CaO.SiO2) - Cl 4 of IS 4032:1985) |
- |
|
|
|
4.1 - Table - 1 xii (Total alkali content, expressed as Sodium Oxide (Na2O) equivalent - Cl 4.11 of IS 4032:1985) |
- |
|
|
|
4.1 - Table - 1 xix (Tetracalcium aluminoferrite (4CaO.Al2O3.Fe2O3) plus twice the tricalcium aluminate (3CaO.Al2O3) - Cl 4 of IS 4032:1985) |
- |
|
|
|
|
Partial
|
|
- |
- |
70 |
IS 8043 (1991) |
Specification for hydrophobic Portland cement |
-
|
- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
5.1 (ref. 6 - Table - 1 i of IS 269:2015) (Ratio of percentage of lime to percentages of silica, alumina and iron oxide - Cl 4 of IS 4032:1985) |
- |
|
|
|
5.1 (ref. 6 - Table - 1 ii of IS 269:2015) (Ratio of percentage of alumina to that of iron oxide - Cl 4 of IS 4032:1985) |
- |
|
|
|
5.1 (ref. 6 - Table - 1 iii of IS 269:2015) (Insoluble residue - Cl 4.10 of IS 4032:1985) |
- |
|
|
|
5.1 (ref. 6 - Table - 1 iv of IS 269:2015) (Magnesia - Cl 4.8 of IS 4032:1985) |
- |
|
|
|
5.1 (ref. 6 - Table - 1 v of IS 269:2015) (Total Sulphur Content calculated as Sulphuric Anhydride (SO3) - Cl 4.9 of IS 4032:1985) |
- |
|
|
|
5.1 (ref. 6 - Table - 1 vi of IS 269:2015) (Loss on ignition - Cl 4.2 of IS 4032:1985) |
- |
|
|
|
5.1 (ref. 6 - Table - 1 vii of IS 269:2015) (Chloride content - Cl 4.13 of IS 4032:1985) |
- |
|
|
|
5.1 (ref. 6 - Table - 1 viii of IS 269:2015) ( Alkali content as (Na2O + 0.658 K2O) - Cl 4.11 of IS 4032:1985) |
- |
|
|
|
|
Partial
|
|
- |
- |
71 |
IS 8041 (1990) |
Rapid hardening portland cement - Specific4tion (Second Revision) |
-
|
- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
5.1 - Table - 1 i (Ratio of percentage of lime to percentages of silica, alumina and iron oxide - Cl 4 of IS 4032:1985) |
- |
|
|
|
5.1 - Table - 1 ii (Ratio of percentage of alumina to that of iron oxide - Cl 4 of IS 4032:1985) |
- |
|
|
|
5.1 - Table - 1 iii (Insoluble residue - Cl 4.10 of IS 4032:1985) |
- |
|
|
|
5.1 - Table - 1 iv (Magnesia - Cl 4.8 of IS 4032:1985) |
- |
|
|
|
5.1 - Table - 1 v (Total Sulphur Content calculated as Sulphuric Anhydride (SO3) - Cl 4.9 of IS 4032:1985) |
- |
|
|
|
5.1 - Table - 1 vi (Total loss on ignition - Cl 4.2 of IS 4032:1985) |
- |
|
|
|
6.1 (Fineness 4031 Part 2) |
- |
|
|
|
6.2.1 (Expansion by Le Chatelier- 4031 Part 3) |
- |
|
|
|
6.2.1 (Expansion by Autoclave- 4031 Part 3) |
- |
|
|
|
6.4 a) (Compressive Strength At 24 hrs ± 30 minutes - IS 4031 Part 6) |
- |
|
|
|
6.4 b) (Compressive Strength At 72 hrs ± 1 hr - IS 4031 Part 6) |
- |
|
|
|
6.3 a) (Setting Time Initial- 4031 Part 5) |
- |
|
|
|
6.3 b) (Setting Time Final- 4031 Part 5) |
- |
|
|
|
|
Partial
|
|
- |
- |
72 |
IS 6909 (1990) |
Supersulphated cement ? specification |
-
|
- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
5.1 (Insoluble residue - Cl 4.10 of IS 4032:1985) |
- |
|
|
|
5.1 (Magnesium Oxide - Cl 4.8 of IS 4032:1985) |
- |
|
|
|
5.1 (Insoluble residue - Cl 4.10 of IS 4032:1985) |
- |
|
|
|
5.1 (Sulphuric anhydride - Cl 4.9 of IS 4032:1985) |
- |
|
|
|
5.1 (Sulphide sulphur - Cl 6.12 of IS 4032:1985) |
- |
|
|
|
|
Partial
|
|
- |
- |
73 |
IS 6452 (1989) |
High alumina cement for structural use - specification (First Revision) |
-
|
- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
4.1 (Total alumina content (Al2O3) - Cl 4.6 of IS 4032:1985) |
- |
|
|
|
|
Partial
|
|
- |
- |
74 |
IS 5346 (1994) |
Synthetic food colour - Preparations and mixtures - Specification (Second Revision) |
-
|
- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Clause 4.5 (Total dye Content) |
- |
|
|
|
Clause 4.6 Table 1 (Water InsoIuble matter,) |
- |
|
|
|
Clause 4.5 (Total dye Content) |
- |
|
|
|
Clause 4.6 Table 1 (Lead (as pb) ) |
- |
|
|
|
Clause 4.6 Table 1 (Arsenic(as As)) |
- |
|
|
|
Clause 4.6 Table 1 (Heavy metals) |
- |
|
|
|
Clause no4.2 (Description) |
- |
|
|
|
|
Complete
|
|
- |
- |
75 |
IS 2052 (2009) |
Compounded feeds for cattle - Specification (Fourth Revision) |
-
|
- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
4.1 (Description - The feed shall be free from harmful constituents, metallic pieces and adulterants. The feed shall also be free from fungal growth and insect infestation. And from fermented . musty, rancid or any other objectionable odour) |
- |
|
|
|
4.3 - Table 1 - i (Moisture - Cl 4 of IS 7874 (Part 1)) |
- |
|
|
|
4.3 - Table 1 - ii (Crude protein (N x 6.25) - Cl 5 of IS 7874 (Part 1)) |
- |
|
|
|
4.3 - Table 1 - iii (Crude fat - Cl 7 of IS 7874 (Part 1)) |
- |
|
|
|
4.3 - Table 1 - iv (Crude fibre - Cl 8 of IS 7874 (Part 1)) |
- |
|
|
|
4.3 - Table 1 - v (Acid insoluble ash - Cl 10 of IS 7874 (Part 1)) |
- |
|
|
|
4.3 - Table 2 - i (Salt (as NaCl) - Cl 4 of IS 7874 (Part 2)) |
- |
|
|
|
4.3 - Table 2 - ii (Calcium (as Ca) - IS 13433 (Part 1 / Part 2)) |
- |
|
|
|
4.3 - Table 2 - iii (Total Phosphorus - IS 14828) |
- |
|
|
|
Cl-7.1,Table-1,Sl.No.xv (Cadmium) |
- |
|
|
|
|
Partial
|
|
- |
- |
76 |
IS 6701 (1985) |
Specification for tungsten filament miscellaneous electric lamps (First Revision) |
-
|
- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Cl 5 of IS 6701:1985 (MARKING) |
- |
|
|
|
Cl 3 of IS 6701:1985 (REQUIREMENTS FOR MECHANICAL AND PHYSICAL
CHARACTERISTICS) |
- |
|
|
|
6.2.1 (Wattage) |
- |
|
|
|
6.2.1 (Lumens) |
- |
|
|
|
6.2.2 (Average Life) |
- |
|
|
|
7.2 (Mechanical, physical and
marking requirements
) |
- |
|
|
|
7.3 (Initial Ratings ) |
- |
|
|
|
7.4 (Life Performance) |
- |
|
|
|
|
Complete
|
|
- |
- |
77 |
IS 15111 : Part 2 (2002) |
Self ballasted lamps for general lighting services: Part 2 performance requirements |
-
|
- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
6 (DIMENSIONS) |
- |
|
|
|
8.1 (STARTING AND RUN-UP) |
- |
|
|
|
8.2 (STARTING AND RUN-UP) |
- |
|
|
|
9 (Lamp Wattage) |
- |
|
|
|
10 (Luminous Flux) |
- |
|
|
|
11 (Colour) |
- |
|
|
|
12 (LUMEN MAINTENANCE) |
- |
|
|
|
13.1 (Life) |
- |
|
|
|
13.2 (Life) |
- |
|
|
|
14 (Harmonics) |
- |
|
|
|
15 (Lamp Efficacy) |
- |
|
|
|
16 (Power factor) |
- |
|
|
|
18.1 (Marking) |
- |
|
|
|
|
Partial
|
|
- |
- |
78 |
IS 15111 : PART 1 AND PART 2 (2002) |
Self ballasted lamps for general lighting services: Part 1 safety requirements |
-
|
- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
6.1 (Marking) |
- |
|
|
|
6.2 (Marking) |
- |
|
|
|
6.3 (Marking) |
- |
|
|
|
6.4 (BIS Certification Marking) |
- |
|
|
|
7 (Interchangeability
) |
- |
|
|
|
8 (Protection against electric shock) |
- |
|
|
|
9.1 (INSULATION RESISTANCE AND ELECTRIC
STRENGTH After HUMIDIT’Y TREATMENT) |
- |
|
|
|
9.2 (Insulation Resistance) |
- |
|
|
|
9.3 (Electric Strength) |
- |
|
|
|
10 (Mechanical strength test
) |
- |
|
|
|
11 (Cap Temperature rise test
) |
- |
|
|
|
12 (Resistance to heat) |
- |
|
|
|
13 (Resistance to Flame and Ignition) |
- |
|
|
|
14 (Fault Conditions) |
- |
|
|
|
|
Partial
|
|
- |
- |
79 |
IS 11673 : Part 2 (2019) |
Sodium hypochlorite solution - Specification: Part 2 water treatment use (Second Revision) |
-
|
- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Cl. 4.3, Table-1, Sr.no. 1 (Relative density (at 25o/25oC)) |
- |
|
|
|
Cl. 4.3, Table-1, Sr.no. 2 (Available Chlorine(as Cl2)) |
- |
|
|
|
Cl. 4.3, Table-1, Sr.no. 3 (Total Chlorine(as Cl2)) |
- |
|
|
|
Cl. 4.3, Table-1, Sr.no. 4 (Free alkali( as NaOH),) |
- |
|
|
|
Cl. 4.3, Table-1, Sr.no. 5 (Free Sodium Carbonate (as Na2CO3)) |
- |
|
|
|
Cl. 4.3, Table-1, Sr.no. 6 (Iron (as Fe)) |
- |
|
|
|
Cl. 4.3, Table-1, Sr.no. 7 (Sodium Chlorate ( as NaClO3),) |
- |
|
|
|
Cl. 4.3, Table-1, Sr.no. 8 (Lead (as Pb)) |
- |
|
|
|
Cl. 4.3, Table-1, Sr.no. 9 (Arsenic (as As)) |
- |
|
|
|
Cl. 4.3, Table-1, Sr.no. 11 (Manganese (as Mn)) |
- |
|
|
|
Cl. 4.3, Table-1, Sr.no. 12 (Total chromium (as Cr)) |
- |
|
|
|
Cl. 4.3, Table-1, Sr.no. 11 (Manganese (as Mn)) |
- |
|
|
|
Cl. 4.3, Table-1, Sr.no. 12 (Total chromium (as Cr)) |
- |
|
|
|
Cl. 4.3, Table-1, Sr.no. 13 (Cadmium (as Cd)) |
- |
|
|
|
Cl. 4.3, Table-1, Sr.no. 14 (Selenium (as Se)) |
- |
|
|
|
Cl. 4.3, Table-1, Sr.no. 10 (Mercury (as Hg)) |
- |
|
|
|
|
Partial
|
|
- |
- |
80 |
IS 418 (2004) |
Tungsten filament lamps for domestic and similar general lighting purposes (Fourth Revision) |
-
|
- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
6 (Marking, IS 418) |
- |
|
|
|
7.1 (Lamp Dimensions, IS 418:2004) |
- |
|
|
|
7.2 (Lamp Dimensions, IS 418:2004) |
- |
|
|
|
8.1 (Wattage, IS 418) |
- |
|
|
|
8.2.1 (Luminous Flux Initial, IS 418) |
- |
|
|
|
8.2.2 (Luminous Flux Initial, IS 418) |
- |
|
|
|
9 (Lumen Maintenance, IS 418) |
- |
|
|
|
10.1 (Life Test Requirements, IS 418) |
- |
|
|
|
10.2 (Life Test Requirements, IS 418) |
- |
|
|
|
7.2 (Lamp Dimensions, IS 418:2004) |
- |
|
|
|
8.1 (Wattage, IS 418) |
- |
|
|
|
8.2.1 (Luminous Flux Initial, IS 418) |
- |
|
|
|
8.2.2 (Luminous Flux Initial, IS 418) |
- |
|
|
|
9 (Lumen Maintenance, IS 418) |
- |
|
|
|
10.1 (Life Test Requirements, IS 418) |
- |
|
|
|
10.2 (Life Test Requirements, IS 418) |
- |
|
|
|
|
Partial
|
|
- |
- |
81 |
IS 398 : Part 4 (1994) |
Aluminium conductors for overhead transmission purposes: Part 4 aluminium alloy stranded conductors (Aluminium - Magnesium - Silicon Type) - Specification (Third Revision) |
-
|
- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
6.1 (Freedom from Defects) |
- |
|
|
|
7.1 Table-1 (Dimensional measurement of wires) |
- |
|
|
|
7.2.2 Table-2, Table-4 (Calculated resistance of Stranded Conductor) |
- |
|
|
|
8.1 (Joints in wires-Conductors Containing Seven Wires) |
- |
|
|
|
8.2 (Joints in wires-Conductors Containing More Than Seven Wires) |
- |
|
|
|
9.1 (Stranding) |
- |
|
|
|
9.2 Table 3 (Lay Ratio of stranded conductors) |
- |
|
|
|
9.3 (Direction of Lay) |
- |
|
|
|
9.4 (Multiple layers of wires) |
- |
|
|
|
11 (Packing and Marking) |
- |
|
|
|
12.2 Table 1 (Breaking Load Test- Before Stranding) |
- |
|
|
|
12.2 Table 1 (Breaking Load Test- After Stranding) |
- |
|
|
|
12.3 Table 1 (Elongation Test- Before Stranding) |
- |
|
|
|
12.3 Table 1 (Elongation Test- After Stranding) |
- |
|
|
|
12.4 Table 1 (Resistance of Aluminium wire) |
- |
|
|
|
|
Partial
|
|
- |
- |
82 |
IS 11673 : Part 1 (2019) |
Sodium hypochlorite solution - Specification: Part 1 household and industrial use (Second Revision) |
-
|
- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Cl. No. 5.1 (Description Grade 1 & 2) |
- |
|
|
|
Cl. No. 5.2 (Keeping quality- available chlorine( table no. 1, cl 5.3, Annex B), Grade 1 & 2) |
- |
|
|
|
Cl. No. 5.3, table no. 1, Sl no. 1 (Relative density, Grade 1, Annex -A) |
- |
|
|
|
Cl. No. 5.3, table no. 1, Sl no. 2 (Available chlorine (as Clâ‚‚), Grade 1, Annex B) |
- |
|
|
|
Cl. No. 5.3, table no. 1, Sl no. 3 (Total chlorine (as Clâ‚‚), Grade 1, Annex C) |
- |
|
|
|
Cl. No. 5.3, table no. 1, Sl no. 4 (Free alkali (as NaOH), Grade 1, Annex D) |
- |
|
|
|
Cl. No. 5.3, table no. 1, Sl no. 5 (Free sodium carbonate (as Na₂CO₃), Grade 1, Annex E) |
- |
|
|
|
Cl. No. 5.3, table no. 1, Sl no. 6 (Iron (as Fe), Grade 1, Annex F) |
- |
|
|
|
Cl. No. 5.3, table no. 1, Sl no. 6 (Iron (as Fe), Grade 1, Annex F) |
- |
|
|
|
Cl. No. 5.3, table no. 1, Sl no. 7 (Sodium chlorate (as NaClO₃), Grade 1, Annex G) |
- |
|
|
|
|
Complete
|
|
- |
- |
83 |
IS 398 : Part 2 (1996) |
Aluminium conductors for overhead transmission purposes - Specification: Part 2 aluminium conuuctors, galvanized steel - Reinforced (Third Revision) |
-
|
- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
8.1.1 & 13.2 Table-1 (mech) (Diameter of Aluminium Wires Before Stranding) |
- |
|
|
|
8.1.1 & 13.2 Table 2 (mech) (Diameter of Steel Wires Before Stranding) |
- |
|
|
|
8.1.1 & 13.2 Table-1 (mech) (Diameter of Aluminium Wires After Stranding) |
- |
|
|
|
8.1.1 & 13.2 Table 2 (mech) (Diameter of Steel Wires After Stranding) |
- |
|
|
|
10 (elec) (Stranding) |
- |
|
|
|
10 (elec) (Stranding) |
- |
|
|
|
10 (elec) (Stranding) |
- |
|
|
|
10 (mech) (Stranding) |
- |
|
|
|
13.3 Table 1 (mech) (Breaking Load of Aluminium Wires Before Stranding) |
- |
|
|
|
13.3 Table 2 (mech) (Breaking Load of Steel Wires Before Stranding) |
- |
|
|
|
13.3 Table 1 (mech) (Breaking Load of Aluminium Wires After Stranding) |
- |
|
|
|
13.3 Table 2 (mech) (Breaking Load of Steel Wires After Stranding) |
- |
|
|
|
13.4.1 (mech) (Ductility by Torsion Test before stranding) |
- |
|
|
|
13.4.1 (mech) (Ductility by Torsion Test before stranding) |
- |
|
|
|
13.4.1 (mech) (Ductility by Torsion Test after stranding) |
- |
|
|
|
13.4.1 (mech) (Ductility by Torsion Test after stranding) |
- |
|
|
|
13.4.2 (elec) (Ductility by Elongation Test before stranding) |
- |
|
|
|
13.4.2 (elec) (Ductility by Elongation Test after stranding) |
- |
|
|
|
13.5.1 (mech) (Wrapping Test Aluminium Wires Before Stranding) |
- |
|
|
|
13.5.1 (mech) (Wrapping Test Aluminium Wires After Stranding) |
- |
|
|
|
13.5.2 (mech) (Wrapping Test Galvanized Steel Wires Before Stranding) |
- |
|
|
|
13.5.2 (mech) (Wrapping Test Galvanized Steel Wires After Stranding) |
- |
|
|
|
13.6 (elec) (Resistance test-Aluminium wire before Stranding) |
- |
|
|
|
13.6 (elec) (Resistance test-Aluminium wire after stranding) |
- |
|
|
|
13.7.2 (chem) (Mass of Zinc coating) |
- |
|
|
|
13.7.2 (chem) (Uniformity of Zinc coating) |
- |
|
|
|
13.8 Table-4 (mech) (Lay Ratio- Aluminium Wire Outermost Layer) |
- |
|
|
|
13.8 Table-4 (mech) (Lay Ratio- Aluminium Wire Layer Immediately Beneath Outermost Layer) |
- |
|
|
|
13.8 Table-4 (mech) (Lay Ratio- Aluminium Wire Innermost Layer of Conductors with 3 Aluminium Wire Layers) |
- |
|
|
|
13.8 Table-4 (mech) (Lay Ratio- Steel Core (6 Wire Layer)) |
- |
|
|
|
13.9 (elec) (Surface condition test) |
- |
|
|
|
|
Partial
|
|
- |
- |
84 |
IS 13334 : Part 2 (2014) |
Skimmed milk powder - Specification: Part 2 extra grade (First Revision) |
-
|
- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Table 1 (ix) (Bacterial count (IS 5402)) |
- |
|
|
|
Table 1 (x) (Coliform count (IS 5401 - Part 1)) |
- |
|
|
|
Table 1 (xi) (Escherichia coli (IS 5887 - Part 1)) |
- |
|
|
|
Table 1 (xii) (Coagulase positive Staphylococcus aureus (IS 5887 - Part 2)) |
- |
|
|
|
Table 1 (xiii) (Salmonella (IS 5887 - Part 3)) |
- |
|
|
|
Table 1 (xiv)(a) (Spore Count: a)Aerobic (Bacillus cereus) Type m (IS 5887 - Part 6)) |
- |
|
|
|
Table 1 (xiv)(b) (Spore Count: b) Anaerobic (Sulfite reducing Clostridia) Type m (ISO 15213 : 2003)) |
- |
|
|
|
Table 1 (xv) (Listeria monocytogenes (IS 14988 - Part 2 : 2001)) |
- |
|
|
|
Table 1 (xiv)(a) (Spore Count: a)Aerobic (Bacillus cereus) Type m (IS 5887 - Part 6)) |
- |
|
|
|
Table 1 (xiv)(b) (Spore Count: b) Anaerobic (Sulfite reducing Clostridia) Type m (ISO 15213 : 2003)) |
- |
|
|
|
Table 1 (i) (Moisture (IS 116231or 16072)) |
- |
|
|
|
Table 1 (ii) (Milk protein in milk solids not fat (IS 72192)) |
- |
|
|
|
Table 1 (iii) (Milk fat (IS 117213) or Annex B) |
- |
|
|
|
Table 1 (iv) (Insolubility index (IS 12759)) |
- |
|
|
|
Table 1 (v) (Total ash (on dry basis), Annex B of IS 14433) |
- |
|
|
|
Table 1 (vi) (Titratable acidity (IS 11766)) |
- |
|
|
|
Table 1 (viii) (Scorched particles (equivalent to Disc B) (IS 13500)) |
- |
|
|
|
|
Partial
|
|
- |
- |
85 |
IS 3466 (1988) |
Specification For Masonry Cement |
-
|
- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
4 ( water soluble alkali content - Cl 9 of IS 4032:1985) |
- |
|
|
|
4.1 (STAINING
IS 4032:1985) |
- |
|
|
|
4.1 (STAINING
IS 4032:1985) |
- |
|
|
|
|
Partial
|
|
- |
- |
86 |
IS 13428 (2005) |
Packaged natural mineral water specification (Second Revision) |
-
|
- View breakup
All except Radio Active Residues (RAR)- Rs 19200.00, All except Pesticide Residues (PRs) & RARs- Rs. 13900.00, All except Micro, PRs & RARs- Rs. 8750.00, Only Micro- Rs. 5900.00
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
6.2 Table-1 i (Colour) |
- |
|
|
|
6.2 Table-1 ii (Odour) |
- |
|
|
|
6.2 Table-1 iii (Taste) |
- |
|
|
|
6.2 Table-1 iv (Turbidity) |
- |
|
|
|
6.2 Table-1 v (Total dissolved solids) |
- |
|
|
|
6.2 Table-1 vi (pH) |
- |
|
|
|
6.2 Table-2 i (Nitrate (as NO3)) |
- |
|
|
|
6.2 Table-2 ii (Nitrite (as NO2)) |
- |
|
|
|
6.2 Table-2 iii (Sulphide (as H2S)) |
- |
|
|
|
6.2 Table-2 iv (Manganese (as Mn)) |
- |
|
|
|
6.2 Table-2 v (Copper (as Cu)) |
- |
|
|
|
6.2 Table-2 vi (Zinc (as Zn)) |
- |
|
|
|
6.2 Table-2 vii (Flouride (as F)) |
- |
|
|
|
6.2 Table-2 viii (Barium (as Ba)) |
- |
|
|
|
6.2 Table-2 ix (Antimony (as Sb)) |
- |
|
|
|
6.2 Table-2 x (Borates (as B)) |
- |
|
|
|
6.2 Table-2 xi (Silver (as Ag)) |
- |
|
|
|
6.2 Table-2 xii (Chloride (as Cl)) |
- |
|
|
|
6.2 Table-2 xiii (Sulphate (as SO4),) |
- |
|
|
|
6.2 Table-2 xiv (Magnesium (as Mg)) |
- |
|
|
|
6.2 Table-2 xv (Calcium (as Ca)) |
- |
|
|
|
6.2 Table-2 xvi (Sodium (as Na)) |
- |
|
|
|
6.2 Table-2 xvii (Alkalinity (as HCO3)) |
- |
|
|
|
6.2 Table-2 xviii (Selenium (as Se)) |
- |
|
|
|
6.2 Table-2 xix (Mineral Oil) |
- |
|
|
|
6.2 Table-3 i (Arsenic (as As)) |
- |
|
|
|
6.2 Table-3 ii (Cadmium (as Cd)) |
- |
|
|
|
6.2 Table-3 iv (Chromium (as Cr)) |
- |
|
|
|
6.2 Table-3 vi (Lead (as Pb) |
- |
|
|
|
6.2 Table-3 vii (Nickel (as Ni)) |
- |
|
|
|
6.2 Table-1 v (Total dissolved solids) |
- |
|
|
|
6.1.1 (Escherichia coli(or thermotolerant bacteria)) |
- |
|
|
|
6.1.2 (Coliform , bacteria) |
- |
|
|
|
6.1.3 (Faecal Streptococci ) |
- |
|
|
|
6.1.3 (Staphylococcus Aureus) |
- |
|
|
|
6.1.4 (Sulphite Reducing Anaerobes ) |
- |
|
|
|
6.1.5 (Pseudomonas Aeruginosa ) |
- |
|
|
|
6.1.6 (Yeast and Mould ) |
- |
|
|
|
6.1.7 (Salmonella ) |
- |
|
|
|
6.1.7 (Shigella) |
- |
|
|
|
6.1.8 (Vibrio cholera ) |
- |
|
|
|
6.1.8 (Vibrio parahemolyticus) |
- |
|
|
|
|
Partial
|
|
- |
- |
87 |
IS 13422 (1992) |
Disposable surgical rubber gloves specification |
-
|
- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
5.4 (Sterility) |
- |
|
|
|
5.2.1 (General Characteristics and Dimensions) |
- |
|
|
|
5.2.2 and Table 1
Fig. 1 (Dimensions - Length) |
- |
|
|
|
5.2.2 and Table 1
Fig. 1 (Dimensions - Width) |
- |
|
|
|
5.2.2 and Table 1
Fig. 1 (Dimensions - Thickness of Finger) |
- |
|
|
|
5.2.2 and Table 1
Fig. 1 (Dimensions - Thickness of Palm) |
- |
|
|
|
5.2.2 and Table 1
Fig. 1 (Dimensions - Thickness of Cuff) |
- |
|
|
|
5.3 and Table 2 ( Tensile Strength Before Ageing) |
- |
|
|
|
5.3 and Table 2 ( Elongation at Break Before Ageing) |
- |
|
|
|
5.3 and Table 2 (Stress at 500% Elongation at Break Before Ageing) |
- |
|
|
|
5.3 and Table 2 ( Tensile StrengthAfter Accelerated Ageing) |
- |
|
|
|
5.3 and Table 2 ( Elongation at Break After Accelerated Ageing) |
- |
|
|
|
5.5 (Airtight Test) |
- |
|
|
|
|
Complete
|
|
- |
- |
88 |
IS 7181 (1986) |
Specification for horizontally cast iron double flanged pipes for water, gas and sewage (First Revision) |
-
|
- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
3.2 (Manufacture) |
- |
|
|
|
3.3 (Manufacture) |
- |
|
|
|
6.1 (Hydrostatic Test) |
- |
|
|
|
7.1 (Sizes and Mass) |
- |
|
|
|
7.2 (Sizes and Mass) |
- |
|
|
|
7.3 (Sizes and Mass) |
- |
|
|
|
7.3 (Sizes and Mass) |
- |
|
|
|
7.3 (Sizes and Mass) |
- |
|
|
|
7.4 (Sizes and Mass Dimensions of Flange) |
- |
|
|
|
7.4 (Sizes and Mass Dimensions of Flange) |
- |
|
|
|
7.4 (Sizes and Mass Dimensions of Flange) |
- |
|
|
|
7.4 (Sizes and Mass Dimensions of Flange) |
- |
|
|
|
7.4 (Sizes and Mass Dimensions of Flange) |
- |
|
|
|
7.4 (Sizes and Mass Dimensions of Flange) |
- |
|
|
|
8.5 (Permissible Deviation from a Straight Line) |
- |
|
|
|
9 (Coating) |
- |
|
|
|
|
Partial
|
|
- |
- |
89 |
IS 5514 (1996) |
Specification Apparatus Used in `Le-chatelier' Test |
-
|
- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
2 (CONSTRUCTION-Thickness) |
- |
|
|
|
2 (CONSTRUCTION-Internal Dia.) |
- |
|
|
|
2 (CONSTRUCTION-Height) |
- |
|
|
|
2 (CONSTRUCTION) |
- |
|
|
|
2 (CONSTRUCTION-Distance between ended) |
- |
|
|
|
2 (CONSTRUCTION-cover plate Weight) |
- |
|
|
|
3-Table 1 (DIMENSIONS-Outer side of the mould to the end of the indicator) |
- |
|
|
|
3-Table 1 (DIMENSIONS-Internal diameter of the mould) |
- |
|
|
|
3-Table 1 (DIMENSIONS-wall thickness of the mould) |
- |
|
|
|
3-Table 1 (DIMENSIONS-wall thickness of the mould) |
- |
|
|
|
3-Table 1 (DIMENSIONS-Split) |
- |
|
|
|
|
Complete
|
|
- |
- |
90 |
IS 5312 : Part 1 (2004) |
Swing Check Type Reflux (Non-Return] Valves for Water Works Purposes - Part 1 : Single-Door Pattern |
-
|
- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
4.1.1 (Actual bore) |
- |
|
|
|
6.2 (Manufacture Dimensions Table 2 ) |
- |
|
|
|
6.2 (Manufacture Dimensions Table 2 ) |
- |
|
|
|
6.4 (Manufacture ) |
- |
|
|
|
6.5 (Manufacture ) |
- |
|
|
|
6.6 (Manufacture ) |
- |
|
|
|
6.7 (Manufacture ) |
- |
|
|
|
6.8 (Manufacture ) |
- |
|
|
|
6.8.1 (Manufacture ) |
- |
|
|
|
6.9 (Manufacture ) |
- |
|
|
|
6.9 (Manufacture ) |
- |
|
|
|
6.9 (Manufacture ) |
- |
|
|
|
6.9 (Manufacture ) |
- |
|
|
|
6.10 (Manufacture ) |
- |
|
|
|
6.10.1 (Manufacture ) |
- |
|
|
|
6.12 (Door Faces) |
- |
|
|
|
6.13 (By-pass arrangements) |
- |
|
|
|
6.13.1 (By-pass arrangements) |
- |
|
|
|
6.13.1 (By-pass arrangements) |
- |
|
|
|
7.1 (Coating) |
- |
|
|
|
8.2 (Hydrostatic Body Test ) |
- |
|
|
|
8.3 (Hydrostatic Seat Test) |
- |
|
|
|
|
Partial
|
|
- |
- |