1 |
IS 16333 : Part 3 (2022) |
Mobile phone handsets: Part 3 Indian language support for mobile phone handsets - Specific requirements(Second Revision) |
-- |
-
|
15000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
5.1(Inputting of text) |
- |
7000 |
|
- |
5.2(Message Readability) |
- |
7000 |
|
- |
6(Marking) |
- |
1000 |
|
- |
|
Complete
|
|
15 May, 2025 |
Revised Version of IS 16333(Part-3):2022. Included w.e.f. 17.05.2023 |
2 |
IS 302 : Part 2 : Sec 15 (2009) |
Safety of household and similar electrical appliances: Part 2 particular requirements: Sec 15 appliances for heating liquids (First Revision) |
-- |
-
|
15000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
6.0(Classification) |
- |
500 |
|
- |
7(Marking and instructions) |
- |
500 |
|
- |
8(Protection against live parts) |
- |
500 |
|
- |
9(STARTING OF MOTOR-OPERATED APPLIANCES) |
- |
0 |
|
- |
10(POWER INPUT AND CURRENT) |
- |
1000 |
|
- |
11(HEATING) |
- |
1000 |
|
- |
13(LEAKAGE CURRENT AND ELECTRIC STRENGTH AT OPERATING TEMPERATURE) |
- |
1000 |
|
- |
14(TRANSIENT OVERVOLTAGES) |
- |
1000 |
|
- |
15(MOISTURE RESISTANCE) |
- |
1000 |
|
- |
16(LEAKAGE CURRENT AND ELECTRIC STRENGTH) |
- |
1000 |
|
- |
17(OVERLOAD PROTECTION OF TRANSFORMERS AND ASSOCIATED CIRCUITS) |
- |
500 |
|
-- |
18(ENDURANCE) |
- |
0 |
|
- |
19(ABNORMAL OPERATION) |
- |
1000 |
|
- |
20(STABILITY AND MECHANICAL HAZARDS) |
- |
500 |
|
-- |
21(MECHANICAL STRENGTH) |
- |
500 |
|
-- |
22(CONSTRUCTION) |
- |
500 |
|
-- |
23(INTERNAL WIRING) |
- |
500 |
|
-- |
24(COMPONENTS) |
- |
500 |
|
-- |
25(SUPPLY CONNECTION AND EXTERNAL FLEXIBLE CORDS) |
- |
500 |
|
-- |
26(TERMINALS FOR EXTERNAL CONDUCTORS) |
- |
500 |
|
-- |
27(PROVISION FOR EARTHING) |
- |
500 |
|
-- |
28(SCREWS AND CONNECTIONS) |
- |
500 |
|
-- |
29(CLEARANCES, CREEPAGE DISTANCES AND SOLID INSULATION) |
- |
500 |
|
-- |
30(RESISTANCE TO HEAT AND FIRE) |
- |
500 |
|
-- |
31(RESISTANCE TO RUSTING) |
- |
500 |
|
-- |
|
Complete
|
|
15 May, 2025 |
Included w.e.f.02-03-2021. Exclusing: EMI/EMC tests (electrostatic Discharges, Radiant Fields, Fast Transient burst, Voltage surges, Injected current, voltage dips & Interruptions, Mains signals) (Cl.19.11.4.1 to Cl.19.11.4.7), Components (Cl.24), Radiation, Toxicity & Similar Hazards (Cl.32). |
3 |
IS 16103 : Part 1 (2012) |
Led modules for general lighting: Part 1 safety requirements |
-- |
-
|
35000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
7(Marking) |
- |
2000 |
|
- |
8(Terminals) |
- |
2000 |
|
- |
9(PROVISION FOR EARTHING) |
- |
4000 |
|
- |
10(Protection against accidental contact with live parts) |
- |
4000 |
|
- |
11(Mositure Resistance and Insulation) |
- |
4000 |
|
- |
12(Electric Strength) |
- |
4000 |
|
- |
13(Fault conditions) |
- |
2000 |
|
- |
15(Construction) |
- |
2000 |
|
- |
16(Creepage distance and clearances) |
- |
2000 |
|
-- |
17(Screws, current carrying parts and connections) |
- |
2000 |
|
-- |
18(Resistance to heat, fire and tracking) |
- |
4000 |
|
- |
19(Resistance to corrosion) |
- |
3000 |
|
- |
|
Complete
|
|
15 May, 2025 |
Included w.e.f.02-03-2021 |
4 |
IS 16333 : Part 3 (2017) |
Mobile phone handsets: Part 3 indian language support for mobile phone handsets - Specific requirements (First Revision) |
-- |
-
|
15000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
5.1(Inputting of text) |
- |
7500 |
|
- |
5.2(Message Readability) |
- |
7500 |
|
- |
|
Complete
|
|
15 May, 2025 |
Included w.e.f.02-03-2021 |
5 |
IS 302 : Part 2 : Sec 6 (2009) |
Safety of household and similar electrical appliances: Part 2 particular requirements: Sec 6 cooking ranges, hobs, ovens and similar appliances (First Revision) |
- |
-
|
15000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
6.0(Classification) |
- |
500 |
|
-- |
7.0(Marking and instructions) |
- |
500 |
|
-- |
8.0(Protection against access to live part test) |
- |
500 |
|
-- |
10.0(Power Input and current test) |
- |
1000 |
|
-- |
11.0(Heating test) |
- |
1000 |
|
-- |
13.0(Leakage current and electric strength test) |
- |
500 |
|
-- |
14.0(Transient voltages) |
- |
1000 |
|
-- |
15.0(Moisture Resistance) |
- |
1000 |
|
-- |
16.0(Leakage current and electric strength test) |
- |
500 |
|
-- |
17.0(Overload protection of transformers test) |
- |
500 |
|
-- |
18.0(Endurance test) |
- |
0 |
|
-- |
19.0(Abnormal Operations) |
- |
1000 |
|
-- |
20.0(Stability and Mechanical Hazards) |
- |
500 |
|
-- |
21.0(Mechanical Strength) |
- |
500 |
|
-- |
22.0(Construction verification related tests) |
- |
500 |
|
-- |
23.0(Internal wiring) |
- |
500 |
|
-- |
24.0(Components) |
- |
500 |
|
-- |
25.0(Supply connections and External Flexible Cords) |
- |
500 |
|
-- |
26.0(Terminal for External Conductors) |
- |
500 |
|
-- |
27.0(Provision for Earthing) |
- |
1000 |
|
-- |
28.0(Screws and connections) |
- |
500 |
|
-- |
29.0(Clearances and Creepage distances and solid insulation) |
- |
500 |
|
-- |
30.0(Resistance to heat and fire) |
- |
500 |
|
-- |
31.0(Resistance to rusting) |
- |
1000 |
|
-- |
|
Complete
|
|
15 May, 2025 |
Exclusing: EMI/EMC tests (electrostatic Discharges, Radiant Fields, Fast Transient burst, Voltage surges, Injected current, voltage dips & Interruptions, Mains signals) (Cl.19.11.4.1 to Cl.19.11.4.7), Components (Cl.24), Radiation, Toxicity & Similar Hazards (Cl.32). |
6 |
IS 13252 : Part 1 (2010) |
Information technology equipment - Safety: Part 1 general requirements (Second Revision) |
-- |
-
|
45000 View breakup
Rs.45,000/- for
Laptop/ notebook/ tablet, Telephone
answering machine, Visual display
unit, video monitors of screen size 32”
& above restricted to 70”, Printer &
Plotters, Scanners, Wireless
Keyboard, Automatic data processing
machine, Set Top Box, Power adaptor
for IT equipments, Mobile phones,
Power bank for use in portable
applications, Cash Registers, Point of
sale terminals, Copying
machine/duplicators, Mail processing
machine/ postage machine/ Franking
machine, Smart card reader, Passport
Reader, Visual Display Units, Video
Monitors of screen size upto 70”,
CCTV Cameras/CCTV Recorders,
USB driven Barcode readers, Barcode
scanners, Iris scanners, Optical
fingerprint scanners, Smart watches.
Additional Products:
Rs.45,000/- for Keyboard, Automatic
Teller Cash Dispensing Machines,
USB Type External Hard Disk Drive,
USB type External Solid State Storage
Devices, Standalone Switch Mode
Power Supplies (SMPS) with output
Voltage 48 V (max.)
[10% Discount to BIS]. ADDITIONAL PRODUCTS FOR PHASE V INCLUDED W.E.F. 01-01-2021:
Rs.45,000/- for Digital Camera
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
1.5(Components) |
- |
1000 |
|
-- |
1.6(Power interface .) |
- |
2000 |
|
-- |
1.7(Markings and instructions) |
- |
1000 |
|
-- |
2.1(Protection from electric shock and energy hazards) |
- |
2000 |
|
-- |
2.2(SELV circuits) |
- |
1000 |
|
-- |
2.3(TNV circuits) |
- |
1000 |
|
-- |
2.4(Limited current circuits) |
- |
2000 |
|
-- |
2.5(Limited power sources .) |
- |
2000 |
|
-- |
2.6(Provisions for earthing and bonding) |
- |
2000 |
|
-- |
2.7(Overcurrent and earth fault protection in primary circuits) |
- |
1000 |
|
-- |
2.8(Safety interlocks) |
- |
1000 |
|
-- |
2.9(Electrical insulation) |
- |
1000 |
|
-- |
2.10(Clearances, creepage distances and distances through insulation) |
- |
2000 |
|
-- |
3.1(General) |
- |
1000 |
|
-- |
3.2(Connection to a mains supply) |
- |
1000 |
|
-- |
3.3(Wiring terminals for connection of external conductors) |
- |
1000 |
|
-- |
3.4(Disconnection from the mains supply) |
- |
1000 |
|
-- |
3.5(Interconnection of equipment) |
- |
1000 |
|
-- |
4.1(Stability) |
- |
1000 |
|
-- |
4.2(Mechanical strength) |
- |
2000 |
|
-- |
4.3(Design and construction) |
- |
1000 |
|
-- |
4.4(Protection against hazardous moving parts) |
- |
1000 |
|
-- |
4.5(Thermal requirements) |
- |
1000 |
|
-- |
4.6(Openings in enclosures) |
- |
1000 |
|
-- |
4.7(Resistance to fire) |
- |
2000 |
|
-- |
5.1(Touch current and protective conductor curren) |
- |
2000 |
|
-- |
5.2(Electric strength) |
- |
2000 |
|
-- |
5.3(Abnormal operating and fault conditions) |
- |
1000 |
|
-- |
6.1(Protection of telecommunication network service persons, and users of other equipment connected to the network, from hazards in the equipment) |
- |
1000 |
|
-- |
6.2(Protection of equipment users from overvoltages on networks telecommunication) |
- |
1000 |
|
-- |
6.3(Protection of the telecommunication wiring system from overheating) |
- |
1000 |
|
-- |
7.1(General) |
- |
1000 |
|
-- |
7.2(Protection of cable distribution system service persons, and users of other equipment connected to the system, from hazardous voltages in the equipment) |
- |
1000 |
|
-- |
7.3(Protection of equipment users from overvoltages on the cable distribution system) |
- |
1000 |
|
-- |
7.4(Insulation between primary circuits and cable distribution systems) |
- |
1000 |
|
-- |
|
Complete
|
|
15 May, 2025 |
Additional Products
Included w.e.f. 29-05-
2020.
Included w.e.f. 17-06-
2019.
Excluding: Component (Cl.1.5), Moving parts (Cl.2.8.5), Switches & Relays (Cl.2.8.7), Semiconductor devices (Cl.2.10.5.4), Insulation in wound component (Cl.2.10.5.11), Wire in wound component (Cl.2.10.5.12), Wire with solvent based enamel in wound components (Cl. 2.10.5.13), Additional insulation in wound components (Cl. 2.10.5.14), Construction of printed boards (Cl.2.10.6), AC power supply cords (Cl.3.2.5.1), Batteries (Cl.4.3.8), Ionizing radiation (Cl.4.3.13.2, Annex H), Effect of UV radiation on materials (Cl. 4.3.13.3), Human exposure to UV radiation (Cl.4.3.13.4), Laser including LED (Cl.4.3.13.5), Motors (Cl.5.3.2), Transformers (Cl.5.3.3), Insulated winding wires for use without interleaved insulation (Annex U) |
7 |
IS 616 (2017) |
Audio, video and similar electronic apparatus - Safety requirements (Fifth Revision) |
-- |
-
|
45000 View breakup
Rs.45,000/- for
Electronic Games [Video], Optical
Disc players with built in amplifiers of
input power 200W and above,
Amplifiers with input power 2000W and
above, Plasma/LCD/LED TVs of
screen size 32'' & above restricted to
70”, Electronic music system with
input power 200W and above,
Power adopters for audio, video &
similar electronic apparatus, Plasma
/LCD/LED TVs of screen size up to 32''
Additional Products:
Rs.45,000/- for Wireless Headphone &
Earphone, Electronic Musical System
with input power below 200W,
Television other than plasma / LCD /
LED/ TVs
[10% Discount to BIS]. ADDITIONAL PRODUCTS FOR PHASE V INCLUDED W.E.F. 01-01-2021:
Rs.45,000/- for:
Wireless Microphone
Video Camera
Webcam (With and without display)
Smart Speaker (With and without display)
Bluetooth Speaker
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
5(Marking and instructions) |
- |
2000 |
|
-- |
7(Heating under normal operating conditions) |
- |
8000 |
|
-- |
8(Constructional requirements with regard to the protection against electric shock) |
- |
4000 |
|
-- |
9(Electric shock hazard under normal operating conditions) |
- |
5000 |
|
-- |
10(Insulation requirements) |
- |
3000 |
|
-- |
11(Fault conditions) |
- |
3000 |
|
-- |
12(Mechanical strength) |
- |
4000 |
|
-- |
13(CLEARANCES and CREEPAGE DISTANCES) |
- |
3000 |
|
-- |
14(Components) |
- |
0 |
|
-- |
15(TERMINALS) |
- |
3000 |
|
-- |
16(External flexible cords) |
- |
2000 |
|
-- |
17(Electrical connections and mechanical fixings) |
- |
2000 |
|
-- |
19(Stability and mechanical hazards) |
- |
3000 |
|
-- |
20(Resistance to fire) |
- |
3000 |
|
-- |
|
Complete
|
|
15 May, 2025 |
Additional Products
Included w.e.f. 29-05-
2020.
Included w.e.f. 17-06-
2019.
Excluding: Ionizing radiation (Cl.6.1), Laser radiation (Cl.6.2), Light emitting diodes (LEDs) (Cl.6.3), Requirements for insulated winding wires for use without additional interleaved insulation (Cl.8.16), Endurance test for wound components with insulated winding wires without additional interleaved insulation (Cl.8.17), Printed boards (Cl.13.5, Cl.20.2.4), Component (Cl.14), Cord Bending Test (Cl.16.3b), Mechanical strength of picture tubes & protection against the effect of implosion (Cl.18), Electrical Components (Cl.20.2.2), Internal wiring (Cl.20.2.3), Components and parts not covered by 20.2.2, 20.2.3 & 20.2.4 (Cl.20.2.5), Fire Enclosure (Cl.20.3), Flammability test methods (Annex G). |
8 |
IS 302 : Part 1 (2008) |
Safety of household and similar electrical appliances: Part 1 general requirements (Sixth Revision) |
-- |
-
|
45000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
7(Marking and instructions) |
- |
500 |
|
--- |
8.1.1(Protection against live parts in all positions) |
- |
500 |
|
-- |
8.1.2(Protection against live parts in openings) |
- |
500 |
|
-- |
8.1.3(Protection against live parts in visible glowing heating elements) |
- |
500 |
|
-- |
8.1.4(Protection against live parts against protective impedance) |
- |
500 |
|
-- |
10.1(Power input) |
- |
1000 |
|
-- |
10.2(Current input) |
- |
1000 |
|
-- |
11.1(General) |
- |
500 |
|
-- |
11.2(General) |
- |
1000 |
|
-- |
11.3(Heating) |
- |
1000 |
|
-- |
13.1(General) |
- |
500 |
|
-- |
13.2(Leakage current at operating temperature) |
- |
1000 |
|
-- |
13.3(Electric Strength at operating temperature) |
- |
500 |
|
-- |
14(Transient Over Voltages) |
- |
1000 |
|
-- |
15.0(General) |
- |
500 |
|
-- |
15.1(Ingress Protection test other than IPX0 (IP test)) |
- |
500 |
|
-- |
15.2(Spillage Test) |
- |
500 |
|
-- |
15.3(Humidity Test) |
- |
500 |
|
--- |
16.0(General) |
- |
500 |
|
--- |
16.1(General) |
- |
500 |
|
-- |
16.2(Leakage Current (after Clause 15)) |
- |
500 |
|
-- |
16.3(Electric Strength (after clause 15 and 16.2)) |
- |
500 |
|
-- |
17(Over Load Protection of Transformers and associated circuits) |
- |
1000 |
|
-- |
18(Endurance Test requirements and tests) |
- |
2000 |
|
-- |
19(Abnormal Operation) |
- |
2000 |
|
-- |
20(Stability test) |
- |
2000 |
|
-- |
21(Mechanical Strength Test) |
- |
2000 |
|
-- |
22(Construction verification related test) |
- |
2000 |
|
--- |
23(General) |
- |
2000 |
|
-- |
24(Components) |
- |
2000 |
|
-- |
25(Supply connection and external flexible cords) |
- |
2000 |
|
-- |
26(Terminals for external conductors) |
- |
2000 |
|
-- |
27(Provision for earthing) |
- |
2000 |
|
-- |
28(Screw test and connections) |
- |
1000 |
|
-- |
29(clearance, creepage distances and solid insulation) |
- |
1000 |
|
-- |
30.1(Ball pressure test) |
- |
500 |
|
-- |
30.2(Glow Wire Test) |
- |
1000 |
|
-- |
30.2(Needle Flame Test) |
- |
500 |
|
-- |
31(Resistance to Rusting) |
- |
1000 |
|
-- |
11.4(Heating appliances) |
- |
1000 |
|
-- |
11.5(Motor-operated appliances) |
- |
1000 |
|
-- |
11.6(Combined appliances) |
- |
1000 |
|
-- |
11.7(Duration corresponding) |
- |
1000 |
|
-- |
11.8(Temperature rise) |
- |
1000 |
|
-- |
|
Complete
|
|
15 May, 2025 |
Excluding: EMI/EMC (Cl.19.11.4.1 to Cl.19.11.4.4), Component (Cl.24) |
9 |
IS 10322 : Part 5 : Sec 7 (2017) |
Luminaires: Part 5 particular requirements: Sec 7 lighting chains (First Revision) |
-- |
-
|
45000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
20.4(General Test Requireements) |
- |
0 |
|
----- |
20.5(Classification of Luminaires') |
- |
1000 |
|
-- |
20.6(Marking) |
- |
1000 |
|
-- |
20.7(Construction) |
- |
5000 |
|
-- |
20.8(Creepage Distance and Clearances) |
- |
3000 |
|
-- |
20.9(Provision for earthing) |
- |
0 |
|
-- |
20.10(Terminals) |
- |
5000 |
|
-- |
20.11(External & Internal Wiring) |
- |
5000 |
|
-- |
20.12(Protection against electric shock) |
- |
5000 |
|
-- |
20.13(Endurance Tests and Thermal Tests) |
- |
5000 |
|
-- |
20.14(Resistance to Dust & Moisture) |
- |
5000 |
|
-- |
20.15(Insulation Resistance and Electric Strength) |
- |
5000 |
|
-- |
20.16(Resistance to Heat , fire and tracking) |
- |
5000 |
|
-- |
|
Complete
|
|
15 May, 2025 |
- |
10 |
IS 10322 : Part 5 : Sec 6 (2013) |
Luminaires: Part 5 particular requirements: Sec 6 handlamps |
-- |
-
|
45000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
8.2(Packing -Each Package shall bear the following Particulars) |
- |
0 |
|
-- |
4(General Test Requireements) |
- |
0 |
|
-- |
5(Classification of Luminaires') |
- |
500 |
|
-- |
6.0(Marking) |
- |
500 |
|
-- |
7.0(Construction) |
- |
5000 |
|
-- |
8.0(Creepage Distance and Clearances) |
- |
1000 |
|
-- |
9.0(Provision for earthing) |
- |
3000 |
|
-- |
10.0(Terminals) |
- |
5000 |
|
-- |
11.0(External & Internal Wiring) |
- |
5000 |
|
-- |
12.0(Protection against electric shock) |
- |
5000 |
|
-- |
13.0(Endurance Tests and Thermal Tests) |
- |
5000 |
|
-- |
14.0(Resistance to Dust & Moisture) |
- |
5000 |
|
-- |
15.0(Insulation Resistance and Electric Strength) |
- |
5000 |
|
-- |
16.0(Resistance to Heat , fire and tracking) |
- |
5000 |
|
-- |
|
Complete
|
|
15 May, 2025 |
- |
11 |
IS 10322 : Part 5 : Sec 1 (2012) |
Luminaires: Part 5 particular requirements: Sec 1 fixed general purpose luminaires (First Revision) |
-- |
-
|
45000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
4(General Test Requireements) |
- |
0 |
|
-- |
5(Classification of Luminaires') |
- |
0 |
|
-- |
6.0(Marking) |
- |
500 |
|
-- |
7.0(Construction) |
- |
5000 |
|
-- |
8.0(Creepage Distance and Clearances) |
- |
1500 |
|
-- |
9.0(Provision for earthing) |
- |
3000 |
|
-- |
10.0(Terminals) |
- |
5000 |
|
-- |
11.0(External & Internal Wiring) |
- |
5000 |
|
-- |
12.0(Protection against electric shock) |
- |
5000 |
|
-- |
13.0(Endurance Tests and Thermal Tests) |
- |
5000 |
|
-- |
14.0(Resistance to Dust & Moisture) |
- |
5000 |
|
-- |
15.0(Insulation Resistance and Electric Strength) |
- |
5000 |
|
-- |
16.0(Resistance to Heat , fire and tracking) |
- |
5000 |
|
-- |
|
Complete
|
|
15 May, 2025 |
Rating upto 400 V only. Excluding: UV Radiation for metal halide lamps (Cl.4.24), Photometric Test (Cl.17) |
12 |
IS 15885 : Part 2 : Sec 13 (2012) |
Safety of lamp controlgear: Part 2 particular requirements: Sec 13 d.c. or a.c. supplied electronic controlgear for led modules |
-- |
-
|
45000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
7(Marking) |
- |
3000 |
|
-- |
8(Protection against accidental contact with live parts) |
- |
3500 |
|
-- |
9(Terminals) |
- |
3500 |
|
-- |
10(PROVISION FOR EARTHING) |
- |
4000 |
|
-- |
11(MOISTURE RESISTANCE) |
- |
4000 |
|
-- |
12(Electric Strength) |
- |
4000 |
|
-- |
13(Thermal endurance test for winding of ballasts) |
- |
0 |
|
-- |
14(Fault conditions) |
- |
4000 |
|
-- |
15(Transformer heating) |
- |
4000 |
|
-- |
16(Construction) |
- |
4000 |
|
-- |
17(Creepage distance and clearances) |
- |
4000 |
|
-- |
18(Screws, current carrying parts and connections) |
- |
4000 |
|
-- |
19(Resistance to heat, fire and tracking) |
- |
4000 |
|
-- |
20(Resistance to corrosion) |
- |
4000 |
|
-- |
|
Complete
|
|
15 May, 2025 |
Excluding: Components: Enclosure, Bridging resistor in primary circuit, Capacitor and RC units, RF suppression (X-Y capacitors), Inductor, MOV/VDR, SMPS/Mains Transformer, PCB material, Metal base PCB for LED, Transparent cover, Bobbin, Insulated tape, Heat shrinkage sleeve, Connector, Fuse, Internal wire, LED, Optocoupler, EMI/EMC filter, Winding wire, Thin sheet materials |
13 |
IS 16102 : Part 1 (2012) |
Self - Ballasted led lamps for general lighting services: Part 1 safety requirements |
-- |
-
|
45000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
5(Marking) |
- |
1000 |
|
-- |
6(Interchangeability) |
- |
2000 |
|
-- |
7(Protection against accidental contact with live parts) |
- |
5000 |
|
-- |
8(Insulation Resistance and Electric Strength) |
- |
5000 |
|
-- |
9(MECHANICAL STRENGTH) |
- |
5000 |
|
-- |
10(cap temperature) |
- |
5000 |
|
-- |
11(Resistance to Heat) |
- |
5000 |
|
-- |
12(Resistance to Flame and Ignition) |
- |
5000 |
|
-- |
13(Fault conditions) |
- |
5000 |
|
-- |
14(Creepage distance and clearances) |
- |
5000 |
|
-- |
5(Marking) |
- |
- |
|
- |
6(Interchangeability) |
- |
- |
|
- |
7(Protection against accidental contact with live parts) |
- |
- |
|
- |
8(Insulation Resistance and Electric Strength) |
- |
- |
|
- |
9(MECHANICAL STRENGTH) |
- |
- |
|
- |
10(cap temperature) |
- |
- |
|
- |
11(Resistance to Heat) |
- |
- |
|
- |
12(Resistance to Flame and Ignition) |
- |
- |
|
- |
13(Fault conditions) |
- |
- |
|
- |
14(Creepage distance and clearances) |
- |
- |
|
- |
|
Complete
|
|
15 May, 2025 |
- |
14 |
IS 10322 : Part 5 : Sec 9 (2017) |
Luminaires: Part 5 particular requirements: Sec 9 rope lights |
-- |
-
|
45000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
21.4(General Test Requireements) |
- |
500 |
|
- |
21.5(Classification of Luminaires') |
- |
500 |
|
- |
21.6(Marking) |
- |
4000 |
|
- |
21.7(Construction) |
- |
4000 |
|
- |
21.8(Creepage Distance and Clearances) |
- |
4000 |
|
- |
21.9(Provision for earthing) |
- |
4000 |
|
- |
21.10(Terminals) |
- |
4000 |
|
- |
21.11(External & Internal Wiring) |
- |
4000 |
|
- |
21.12(Protection against electric shock) |
- |
4000 |
|
- |
21.13(Endurance Tests and Thermal Tests) |
- |
4000 |
|
- |
21.14(Resistance to Dust & Moisture) |
- |
4000 |
|
- |
21.15(Insulation Resistance and Electric Strength) |
- |
4000 |
|
- |
21.16(Resistance to Heat , fire and tracking) |
- |
4000 |
|
- |
|
Complete
|
|
15 May, 2025 |
Included w.e.f. 17.05.2023 |
15 |
IS 16046 : Part 2 (2018) |
Secondary Cells and Batteries Containing Alkaline or Other Non-Acid Electrolytes ” Safety Requirements for Portable Sealed Secondary Cells and for Batteries Made from Them for Use in Portable Applications Part 2 Lithium Systems ( Second Revision ) |
-- |
-
|
45000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
4(Parameter Measurement Tolerances) |
- |
500 |
|
- |
5(General Safety Considerations) |
- |
500 |
|
- |
5.1(General) |
- |
500 |
|
- |
5.2(Insulation and Wiring) |
- |
1500 |
|
- |
5.3(Venting) |
- |
500 |
|
- |
5.4(Temperature, Voltage and Current Management) |
- |
500 |
|
- |
5.5(Terminal Contacts) |
- |
2500 |
|
- |
5.6(Assembly of Cells into batteries) |
- |
2500 |
|
- |
5.7(Quality Plan) |
- |
500 |
|
- |
5.8(Battery Safety Components) |
- |
2500 |
|
- |
6(Type Test and Sample Size) |
- |
2500 |
|
- |
7(Specific requirements and tests) |
- |
500 |
|
- |
7.1(Charging procedure for test purposes) |
- |
2500 |
|
- |
7.2(Intended Use) |
- |
2500 |
|
- |
7.3(Reasonably foreseeable misuse) |
- |
2500 |
|
- |
8(Information for safety) |
- |
2500 |
|
- |
8.1(General) |
- |
2500 |
|
- |
8.2(Small Cell and battery safety information) |
- |
2500 |
|
- |
9(Marking) |
- |
2500 |
|
- |
9.1(Cell Marking) |
- |
2500 |
|
- |
9.2(Battery Marking) |
- |
2500 |
|
- |
9.3(Caution for ingestion of small cells and batteries) |
- |
2500 |
|
- |
9.4(Other information) |
- |
2500 |
|
- |
10(Packaging) |
- |
2500 |
|
- |
4(Parameter Measurement Tolerances) |
- |
500 |
|
- |
5(General Safety Considerations) |
- |
500 |
|
- |
5.1(General) |
- |
500 |
|
- |
5.2(Insulation and Wiring) |
- |
1500 |
|
- |
5.3(Venting) |
- |
500 |
|
- |
5.4(Temperature, Voltage and Current Management) |
- |
500 |
|
- |
5.5(Terminal Contacts) |
- |
2500 |
|
- |
5.6(Assembly of Cells into batteries) |
- |
2500 |
|
- |
5.7(Quality Plan) |
- |
500 |
|
- |
5.8(Battery Safety Components) |
- |
2500 |
|
- |
6(Type Test and Sample Size) |
- |
2500 |
|
- |
7(Specific requirements and tests) |
- |
500 |
|
- |
7.1(Charging procedure for test purposes) |
- |
2500 |
|
- |
7.2(Intended Use) |
- |
2500 |
|
- |
7.3(Reasonably foreseeable misuse) |
- |
2500 |
|
- |
8(Information for safety) |
- |
2500 |
|
- |
8.1(General) |
- |
2500 |
|
- |
8.2(Small Cell and battery safety information) |
- |
2500 |
|
- |
9(Marking) |
- |
2500 |
|
- |
9.1(Cell Marking) |
- |
2500 |
|
- |
9.2(Battery Marking) |
- |
2500 |
|
- |
9.3(Caution for ingestion of small cells and batteries) |
- |
2500 |
|
- |
9.4(Other information) |
- |
2500 |
|
- |
10(Packaging) |
- |
2500 |
|
- |
4(Parameter Measurement Tolerances) |
- |
500 |
|
- |
5(General Safety Considerations) |
- |
500 |
|
- |
5.1(General) |
- |
500 |
|
- |
5.2(Insulation and Wiring) |
- |
1500 |
|
- |
5.3(Venting) |
- |
500 |
|
- |
5.4(Temperature, Voltage and Current Management) |
- |
500 |
|
- |
5.5(Terminal Contacts) |
- |
2500 |
|
- |
5.6(Assembly of Cells into batteries) |
- |
2500 |
|
- |
5.7(Quality Plan) |
- |
500 |
|
- |
5.8(Battery Safety Components) |
- |
2500 |
|
- |
6(Type Test and Sample Size) |
- |
2500 |
|
- |
7(Specific requirements and tests) |
- |
500 |
|
- |
7.1(Charging procedure for test purposes) |
- |
2500 |
|
- |
7.2(Intended Use) |
- |
2500 |
|
- |
7.3(Reasonably foreseeable misuse) |
- |
2500 |
|
- |
8(Information for safety) |
- |
2500 |
|
- |
8.1(General) |
- |
2500 |
|
- |
8.2(Small Cell and battery safety information) |
- |
2500 |
|
- |
9(Marking) |
- |
2500 |
|
- |
9.1(Cell Marking) |
- |
2500 |
|
- |
9.2(Battery Marking) |
- |
2500 |
|
- |
9.3(Caution for ingestion of small cells and batteries) |
- |
2500 |
|
- |
9.4(Other information) |
- |
2500 |
|
- |
10(Packaging) |
- |
2500 |
|
- |
|
Complete
|
|
15 May, 2025 |
Included w.e.f. 17.05.2023 |
16 |
IS 16046 : Part 1 (2018) |
Secondary Cells and Batteries Containing Alkaline or Other Non-Acid Electrolytes ” Safety Requirements for Portable Sealed Secondary Cells and for Batteries Made from Them for Use in Portable Applications Part 1 Nickel Systems ( Second Revision ) |
-- |
-
|
45000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
4(Parameter Measurement Tolerances) |
- |
500 |
|
- |
4(Parameter Measurement Tolerances) |
- |
500 |
|
- |
5(General Safety Considerations) |
- |
500 |
|
- |
5.1(General) |
- |
500 |
|
- |
5.2(Insulation and Wiring) |
- |
1500 |
|
- |
5.3(Venting) |
- |
500 |
|
- |
5.4(Temperature, Voltage and Current Management) |
- |
500 |
|
- |
5.5(Terminal Contacts) |
- |
2000 |
|
- |
5.6(Assembly of Cells into batteries) |
- |
2000 |
|
- |
5.7(Quality Plan) |
- |
500 |
|
- |
6(Tyoe Test amd Sample Size) |
- |
2000 |
|
- |
7(Specific requirements and tests) |
- |
500 |
|
- |
7.1(Charging procedure for test purposes) |
- |
2000 |
|
- |
7.2(Intended Use) |
- |
3000 |
|
- |
7.3(Reasonably foreseeable misuse) |
- |
4000 |
|
- |
8(Information for safety) |
- |
2000 |
|
- |
4(Parameter Measurement Tolerances) |
- |
500 |
|
- |
5(General Safety Considerations) |
- |
500 |
|
- |
5.1(General) |
- |
500 |
|
- |
5.2(Insulation and Wiring) |
- |
1500 |
|
- |
5.3(Venting) |
- |
500 |
|
- |
5.4(Temperature, Voltage and Current Management) |
- |
500 |
|
- |
5.5(Terminal Contacts) |
- |
2000 |
|
- |
5.6(Assembly of Cells into batteries) |
- |
2000 |
|
- |
5.7(Quality Plan) |
- |
500 |
|
- |
6(Tyoe Test amd Sample Size) |
- |
2000 |
|
- |
7(Specific requirements and tests) |
- |
500 |
|
- |
7.1(Charging procedure for test purposes) |
- |
2000 |
|
- |
7.2(Intended Use) |
- |
3000 |
|
- |
7.3(Reasonably foreseeable misuse) |
- |
4000 |
|
- |
8(Information for safety) |
- |
2000 |
|
- |
8.1(General) |
- |
2000 |
|
- |
8.2(Small Cell and battery safety information) |
- |
3000 |
|
- |
9(Marking) |
- |
3000 |
|
- |
9.1(Cell Marking) |
- |
3000 |
|
- |
9.3(Caution for ingestion of small cells and batteries) |
- |
3000 |
|
- |
9.4(Other information) |
- |
3000 |
|
- |
10(Packaging) |
- |
3000 |
|
- |
4(Parameter Measurement Tolerances) |
- |
500 |
|
- |
5(General Safety Considerations) |
- |
500 |
|
- |
5.1(General) |
- |
500 |
|
- |
5.2(Insulation and Wiring) |
- |
1500 |
|
- |
5.3(Venting) |
- |
500 |
|
- |
5.4(Temperature, Voltage and Current Management) |
- |
500 |
|
- |
5.5(Terminal Contacts) |
- |
2000 |
|
- |
5.6(Assembly of Cells into batteries) |
- |
2000 |
|
- |
5.7(Quality Plan) |
- |
500 |
|
- |
6(Tyoe Test amd Sample Size) |
- |
2000 |
|
- |
7(Specific requirements and tests) |
- |
500 |
|
- |
7.1(Charging procedure for test purposes) |
- |
2000 |
|
- |
7.2(Intended Use) |
- |
3000 |
|
- |
7.3(Reasonably foreseeable misuse) |
- |
4000 |
|
- |
8(Information for safety) |
- |
2000 |
|
- |
8.1(General) |
- |
2000 |
|
- |
8.2(Small Cell and battery safety information) |
- |
3000 |
|
- |
9(Marking) |
- |
3000 |
|
- |
9.1(Cell Marking) |
- |
3000 |
|
- |
9.3(Caution for ingestion of small cells and batteries) |
- |
3000 |
|
- |
9.4(Other information) |
- |
3000 |
|
- |
10(Packaging) |
- |
3000 |
|
- |
9.2(Battery Marking) |
- |
3000 |
|
- |
|
Complete
|
|
15 May, 2025 |
Included w.e.f. 17.05.2023 |