31 |
IS 7887 (1992) |
Mild steel wire rod for general engineering purposes - Specification (First Revision) |
I,2,3,4,4M,5,6,6M,7,7M,8,8M,9,10,10M |
6800 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Cl 9(Nominal Diameter & Out Of Shape) |
- |
800 |
|
.... |
Cl 8(Workmanship) |
- |
500 |
|
.... |
6.1(Carbon %) |
- |
900 |
|
... |
6.1(Manganese %) |
- |
900 |
|
... |
6.1(Phosphorus %) |
- |
900 |
|
..... |
6.1(Sulphur %) |
- |
900 |
|
.... |
6.1(Silicon %) |
- |
900 |
|
.... |
6.1( Aluminium %) |
- |
1000 |
|
.... |
|
07 Sep, 2025 |
- - |
32 |
IS 6603 (2001) |
Stainless steel bars and flats - Specification (First Revision) |
ANNEALED/SOFTENED/HARDENED&TEMPERED/COLD FINISH |
8500 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
9.2, Table 3(Tensile Strength, MPa) |
- |
1000 |
|
... |
9.5, Table 3(Charpy Impact Test, J-IS 1499) |
- |
1500 |
|
...... |
9.3, Table 3(Elongation ,Percent) |
- |
600 |
|
... |
9.1, Table 3(0.2 Percent Proof Stress, MPa) |
- |
600 |
|
... |
6(Freedom from defects:) |
- |
200 |
|
... |
9.4, Table 3(Annealed Hardness, HB-IS 1500: Pt 1) |
- |
500 |
|
... |
12(Dimensions & Tolerances, mm-IS 6603) |
- |
100 |
|
... |
12(Diameter, mm) |
- |
100 |
|
... |
12(Out of Round , mm) |
- |
100 |
|
... |
12(Length , mm) |
- |
100 |
|
... |
12(Variation in Straightness) |
- |
100 |
|
... |
Cl.14.1(Corrosion Resistance- IS 10461(Part1)) |
- |
2000 |
|
.... |
Cl.14.1(Corrosion Resistance- IS 10461(Part2)) |
- |
2000.01 |
|
.... |
Cl. 7.1, 7.2, 7.3 & 13.1 Table 1(Carbon -Established instrumental/ chemical method as agreed to between purchaser and the manufacturer.) |
- |
700 |
|
... |
Cl. 7.1, 7.2, 7.3 & 13.1 Table 1(Silicon- Established instrumental/ chemical method as agreed to between purchaser and the manufacturer.) |
- |
700 |
|
.... |
Cl. 7.1, 7.2, 7.3 & 13.1 Table 1(Manganese- Established instrumental/ chemical method as agreed to between purchaser and the manufacturer.) |
- |
700 |
|
.... |
Cl. 7.1, 7.2, 7.3 & 13.1 Table 1(Nickel -Established instrumental/ chemical method as agreed to between purchaser and the manufacturer.) |
- |
700 |
|
.... |
Cl. 7.1, 7.2, 7.3 & 13.1 Table 1(Chromium- Established instrumental/ chemical method as agreed to between purchaser and the manufacturer.) |
- |
700 |
|
... |
Cl. 7.1, 7.2, 7.3 & 13.1 Table 1(Molybdenum- Established instrumental/ chemical method as agreed to between purchaser and the manufacturer.) |
- |
700 |
|
.... |
Cl. 7.1, 7.2, 7.3 & 13.1 Table 1(Titanium- Established instrumental/ chemical method as agreed to between purchaser and the manufacturer.) |
- |
700 |
|
... |
Cl. 7.1, 7.2, 7.3 & 13.1 Table 1(Niobium- Established instrumental/ chemical method as agreed to between purchaser and the manufacturer.) |
- |
700 |
|
.... |
Cl. 7.1, 7.2, 7.3 & 13.1 Table 1(Sulphur- Established instrumental/ chemical method as agreed to between purchaser and the manufacturer.) |
- |
700 |
|
.... |
Cl. 7.1, 7.2, 7.3 & 13.1 Table 1(Phosphorus- Established instrumental/ chemical method as agreed to between purchaser and the manufacturer.) |
- |
700 |
|
.... |
Cl. 7.1, 7.2, 7.3 & 13.1 Table 1(Others (Nitrogen)- Established instrumental/ chemical method as agreed to between purchaser and the manufacturer.) |
- |
4000 |
|
.... |
Cl. 12
Table 9, 11 & 13 (Square Size) |
- |
100 |
|
.. |
Cl. 12
Table 11,13 & 14(Thickness of Flat) |
- |
50 |
|
... |
Cl. 12
Table 11,13 & 14(Width of Flat) |
- |
50 |
|
.. |
Cl. 12
Table 10 & 13(Hexagonal Size) |
- |
50 |
|
.. |
Cl. 12
Table 9(Out of Square) |
- |
50 |
|
.. |
Cl. 12
Table 10(Maximum Differences in Three Measurements for Hexagons) |
- |
50 |
|
... |
Cl. 9.3 Table 3(Bend Test) |
- |
100 |
|
... |
|
07 Sep, 2025 |
- - |
33 |
IS 6528 (1995) |
Stainless steel wire - Specification (First Revision) |
0.071 MM-12.5 AND ABOVE ACCORDING TO 6528 |
11500 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Cl 10(UTM) |
- |
1000 |
|
-- |
Cl 9.1 & Table 3(Diameter & Out Of Round) |
- |
500 |
|
--- |
Cl 6(Workmanship) |
- |
150 |
|
.. |
Table 7(Workmanship) |
- |
150 |
|
.... |
Table-1,( Clauses 7.1, 7.2, 7.3 and 12.1)(Nitrogen) |
- |
800 |
|
.. |
Table-1,( Clauses 7.1, 7.2, 7.3 and 12.1)(Titanium) |
- |
800 |
|
.. |
Table-1,( Clauses 7.1, 7.2, 7.3 and 12.1)(Copper) |
- |
800 |
|
.. |
Table-1,( Clauses 7.1, 7.2, 7.3 and 12.1)(Molybdenum) |
- |
800 |
|
.. |
Table-1,( Clauses 7.1, 7.2, 7.3 and 12.1)(Nickel) |
- |
800 |
|
.. |
Table-1,( Clauses 7.1, 7.2, 7.3 and 12.1)(Chromium) |
- |
800 |
|
.. |
Table-1,( Clauses 7.1, 7.2, 7.3 and 12.1)(Aluminium) |
- |
800 |
|
... |
Table-1,( Clauses 7.1, 7.2, 7.3 and 12.1)(Silicon) |
- |
800 |
|
.. |
Table-1,( Clauses 7.1, 7.2, 7.3 and 12.1)(Manganese) |
- |
800 |
|
.. |
Table-1,( Clauses 7.1, 7.2, 7.3 and 12.1)(Phosphorous) |
- |
800 |
|
.. |
Table-1,( Clauses 7.1, 7.2, 7.3 and 12.1)(Sulphor) |
- |
800 |
|
.. |
Table-1,( Clauses 7.1, 7.2, 7.3 and 12.1)(Carbon) |
- |
800 |
|
4000/- extra corrosion test |
|
07 Sep, 2025 |
- - |
34 |
IS 7181 (1986) |
Specification for horizontally cast iron double flanged pipes for water, gas and sewage (First Revision) |
UP TO 600 MM |
8500 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
5.1(Tensile Test) |
- |
2000 |
|
-- |
6.1(Hydrostatic Test) |
- |
2000 |
|
.. |
3.1(Manufacture) |
- |
100 |
|
... |
3.2(Manufacture) |
- |
100 |
|
... |
3.3(Manufacture) |
- |
100 |
|
... |
3.4(Manufacture) |
- |
100 |
|
... |
3.5(Manufacture) |
- |
100 |
|
... |
7.1(Sizes and Mass) |
- |
100 |
|
... |
7.2(Sizes and Mass) |
- |
100 |
|
... |
7.3(Sizes and Mass) |
- |
100 |
|
.... |
7.3(Sizes and Mass) |
- |
100 |
|
... |
7.3(Sizes and Mass) |
- |
100 |
|
... |
7.4(Sizes and Mass Dimensions of Flange) |
- |
500 |
|
... |
7.4(Sizes and Mass Dimensions of Flange) |
- |
100 |
|
... |
7.4(Sizes and Mass Dimensions of Flange) |
- |
100 |
|
... |
7.4(Sizes and Mass Dimensions of Flange) |
- |
100 |
|
... |
7.4(Sizes and Mass Dimensions of Flange) |
- |
100 |
|
... |
7.4(Sizes and Mass Dimensions of Flange) |
- |
100 |
|
... |
7.4(Sizes and Mass Dimensions of Flange) |
- |
100 |
|
... |
7.4(Sizes and Mass Dimensions of Flange) |
- |
100 |
|
... |
7.4(Sizes and Mass Dimensions of Flange) |
- |
100 |
|
... |
8.5(Permissible Deviation from a Straight Line) |
- |
100 |
|
... |
9(Coating) |
- |
1000 |
|
.... |
|
07 Sep, 2025 |
- Size upto 300mm |
35 |
IS 2202 : Part 1 (1999) |
Wooden flush door shutters (Solid Core Type) - Specification: Part 1 plywood face panels (Sixth Revision) |
BWP/BN |
30000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
11.11(Varying Humidity Test - IS 4020(Pt-12)) |
- |
6000 |
|
--- |
11.15(Screw Withdrawal Resistance test - IS 4020 (Pt-16)) |
- |
500 |
|
... |
11.15(Screw Withdrawal Strength - IS 4020 (Pt-16)) |
- |
2000 |
|
.... |
11.14(Glue Adhesion Test - IS 4020(Pt-15)) |
- |
1500 |
|
.... |
11.13(Knife Test - IS 4020(Pt-14)) |
- |
1000 |
|
..... |
11.12(End Immersion Test - IS 4020(Pt-13)) |
- |
2000 |
|
..... |
11.11(The recovery of the original size after subjecting the door to high and low humidity- IS 4020(Pt-12)) |
- |
1000 |
|
.... |
11.11(Maximum departure from the general planeness - IS 4020(Pt-12)) |
- |
1000 |
|
.... |
11.1(Misuse Test - IS 4020(Pt-11)) |
- |
1500 |
|
..... |
11.9(Slamming Test - IS 4020(Pt-10)) |
- |
1500 |
|
.... |
11.8(Residual deformation after 15 minutes of unloading - IS 4020(Pt-9)) |
- |
500 |
|
.... |
11.8(Initial deflection - IS 4020(Pt-9)) |
- |
500 |
|
..... |
11.8(Buckling Test - IS 4020(Pt-9)) |
- |
1000 |
|
.... |
11.7(Shock Resistance Test -IS 4020(Pt-8)) |
- |
800 |
|
.... |
11.7(Shock Resistance Test -IS 4020(Pt-8)) |
- |
700 |
|
.... |
11.6(Residual lateral buckling - IS 4020(Pt-7)) |
- |
500 |
|
.... |
11.6(Lateral buckling during loading - IS 4020(Pt-7)) |
- |
500 |
|
.... |
11.6(Residual deflection after removal of load - IS 4020(Pt-7)) |
- |
500 |
|
... |
11.6(Deflection of the edge at maximum load - IS 4020(Pt-7)) |
- |
500 |
|
.... |
11.5(Residual deflection - IS 4020(Pt-6)) |
- |
1000 |
|
.... |
11.5(Deflection at maximum load - IS 4020(Pt-6)) |
- |
500 |
|
... |
11.4(Depth of indentation - IS 4020(Pt-5)) |
- |
500 |
|
.... |
11.4(Impact Indentation Test - IS 4020(Pt-5)) |
- |
500 |
|
... |
11.3(Depth of deviation - IS 4020(Pt-4)) |
- |
500 |
|
..... |
11.2( Twist, cupping & wrapping - IS 4020 (Pt-3)) |
- |
1000 |
|
.... |
11.1( Squareness Test - IS 4020 (Pt-2)) |
- |
200 |
|
.... |
11.1(Variation in thickness - IS 4020 (Pt-2)) |
- |
200 |
|
.... |
11.1(Thickness - IS 4020 (Pt-2)) |
- |
200 |
|
.... |
11.1(Width- IS 4020 (Pt-2)) |
- |
200 |
|
.... |
11.1(Height - IS 4020 (Pt-2)) |
- |
200 |
|
... |
6.2(Plywood) |
- |
500 |
|
... |
9.2(Workmanship & finish - IS 2202(Pt-1)) |
- |
500 |
|
.. |
9.3(Workmanship & finish - IS 2202(Pt-1)) |
- |
500 |
|
... |
|
07 Sep, 2025 |
- - |
36 |
IS 14329 (1995) |
Malleable iron castings - Specification |
WM 350 to PM 700 |
4500 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
8.0(FREEDOM FROM DEFECTS) |
- |
200 |
|
.. |
9.2.1, 10.1, Table 1(Nominal diameter) |
- |
100 |
|
... |
9.2.1, 10.1, Table 1(Tolerances on nominal diameter) |
- |
100 |
|
... |
9.2.1, 10.1, Table 1(Shank Dimensions, Diameter) |
- |
100 |
|
... |
9.2.1, 10.1, Table 1(Shank Dimensions, Length) |
- |
100 |
|
.. |
9.2.1, 10.1, Table 1(Gauge length) |
- |
100 |
|
.. |
9.2.1, 10.1, Table 1(Length) |
- |
100 |
|
.. |
9.2.1, 10.1, Table 1(Radius at shoulder) |
- |
100 |
|
... |
10.1(Tensile Test) |
- |
1500 |
|
.... |
10.2(Hardness Test) |
- |
500 |
|
.... |
10.1, 10.2, Table 2(Grade Designation ) |
- |
100 |
|
... |
10.1, 10.2, Table 2(Sectional thickness represented) |
- |
100 |
|
... |
10.1, 10.2, Table 2(Diameter of Test bar) |
- |
100 |
|
... |
10.1, 10.2, Table 2(Tensile Strength ) |
- |
1000 |
|
.... |
10.1, 10.2, Table 2(0.2 % Proof stress) |
- |
300 |
|
... |
10.1, 10.2, Table 2(Elongation) |
- |
300 |
|
.... |
10.1, 10.2, Table 2(Hardness) |
- |
500 |
|
.... |
|
07 Sep, 2025 |
- - |
37 |
IS 318 (1981) |
Specification for leaded tin bronze ingots and castings (Second Revision) |
ALL |
6500 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
7(SIZE AND SHAPE) |
- |
500 |
|
... |
6(FREEDOM FROM DEFECTS) |
- |
500 |
|
... |
4, Table 2.(MECHANICAL PROPERTIES) |
- |
1500 |
|
... |
3, Table 1.(CHEMlCAL COMPOSITION) |
- |
800 |
|
800 PER PARATMETER |
7.2(Dimension) |
- |
100 |
|
... |
7.1(Mass) |
- |
200 |
|
... |
6.2(Freedom from defects-Castings) |
- |
100 |
|
.. |
6.1(Freedom from defects-Ingots) |
- |
100 |
|
... |
4.1, Table 2(Elongation) |
- |
100 |
|
... |
4.1, Table 2(0.2% Proof stress) |
- |
200 |
|
... |
4.1, Table 2(Tensile strength) |
- |
500 |
|
... |
|
07 Sep, 2025 |
- - |
38 |
IS 10748 (2004) |
Hot - Rolled steel strip for welded tubes and pipes - Specification (Second Revision) |
GRADE 1, 2,3,4,5 |
5500 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Cl 8 & Table 3(UTM) |
- |
1000 |
|
... |
Cl 9(Press) |
- |
500 |
|
... |
Cl 11(Workmanship) |
- |
200 |
|
... |
Cl 12 & 13(Length, Width & Thickness) |
- |
200 |
|
... |
7.1(Carbon %) |
- |
800 |
|
... |
7.1(Manganese %) |
- |
800 |
|
... |
7.1(Phosphorus %) |
- |
800 |
|
... |
7.1(Sulphur %) |
- |
800 |
|
... |
7.1(Silicon %) |
- |
800 |
|
... |
7.1( Copper %) |
- |
800 |
|
... |
7.1( Aluminium %) |
- |
800 |
|
... |
7.1( Nb) |
- |
800 |
|
... |
7.1(V) |
- |
800 |
|
... |
7.1( Ti) |
- |
800 |
|
... |
7.1(Cr) |
- |
800 |
|
... |
7.1(Mo) |
- |
800 |
|
... |
7.1(Ni) |
- |
800 |
|
... |
7.1( Nitrogen%) |
- |
4000 |
|
... |
|
07 Sep, 2025 |
- - |
39 |
IS 319 (2007) |
Free cutting brass bars, rods and section - Specification (Fifth Revision) |
GRADE-1 & GRADE 2 ,TYPE -O /HB/HD |
6000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
5.0(Freedom from defects) |
- |
100 |
|
... |
7.0(Dimension and Tolerances) |
- |
100 |
|
... |
8.1 Table 1(Cu) |
- |
500 |
|
... |
8.1 Table 1(Pb) |
- |
500 |
|
... |
8.1 Table 1(Fe) |
- |
500 |
|
... |
8.1 Table 1(Total other impurities excluding iron) |
- |
100 |
|
... |
8.1 Table 1(Zn) |
- |
500 |
|
... |
9.1 Table-2(Tensile Strength) |
- |
1000.01 |
|
... |
9.1 Table-2(Elongation) |
- |
600 |
|
... |
9.2(Vickers Hardness) |
- |
500 |
|
... |
10.1(Mercurous Nitrate Test) |
- |
800 |
|
.... |
|
07 Sep, 2025 |
- - |
40 |
IS 513 : Part 2 (2016) |
Cold reduced carbon steel sheet and strip: Part 2 high tensile and multi - Phase steel (Sixth Revision) |
ALL |
6800 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Cl 7(UTM) |
- |
1000 |
|
... |
Cl 8.5(Workmanship) |
- |
100 |
|
... |
Cl 8.6(Workmanship) |
- |
100 |
|
... |
Cl 9(Workmanship) |
- |
100 |
|
... |
Cl 10(Length, Width & Thickness) |
- |
500 |
|
... |
6.0(ALUMINIUM) |
- |
700 |
|
... |
6.0(MICRO ALLOYS) |
- |
100 |
|
... |
6.0(NITROGEN) |
- |
4000 |
|
... |
6.0(SILICON) |
- |
700 |
|
... |
6.0(MANGANESE) |
- |
700 |
|
... |
6.0(PHOSPHORUS) |
- |
700 |
|
... |
6.0(SULPHUR) |
- |
700 |
|
... |
6.0(CARBON) |
- |
700 |
|
... |
Cl. 10(Out of square) |
- |
100 |
|
... |
Cl. 10(Flatness) |
- |
100 |
|
... |
Cl. 10(Camber) |
- |
100 |
|
... |
Cl. 10(Width) |
- |
100 |
|
... |
Cl. 10(Thickness) |
- |
100 |
|
.... |
Cl. 8.5.3 Table 6(Surface Roughness) |
- |
500 |
|
.... |
Cl. 7.3 Table 4A & 4B(Tensile Strain Hardening) |
- |
1000 |
|
... |
Cl. 7.2 Table 7(Bend Test) |
- |
500 |
|
... |
Cl 10(Length, Width & Thickness) |
- |
200 |
|
.... |
|
07 Sep, 2025 |
- - |
41 |
IS 4990 (2024) |
PLYWOOD FOR CONCRETE SHUTTERING WORKS SPECIFICATION (Fourth Revision) |
Grade-BWP/ Type- CS/ CSC/CSFF /All Size as per IS |
16000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Cl-5.1(Timber) |
- |
8000 |
|
FACE VENEER -2500/-
CORE VENEER-2500/-
FILM FACE & BASE PAPER -3000/- |
Cl-5.2(Adhesives for Bonding of Veneers) |
- |
9000 |
|
- |
Cl-6.1(Manufacture) |
- |
100 |
|
- |
Cl-6.2(Manufacture ( Thickness of veneers)) |
- |
100 |
|
- |
Cl-6.3(Manufacture ( Physical and mechanical properties of veneers)) |
- |
100 |
|
- |
Cl-6.4, 6.7(Manufacture (Plywood for concrete shuttering)) |
- |
100 |
|
- |
Cl-6.5(Manufacture (Scarf joints)) |
- |
100 |
|
- |
Cl-6.6(Manufacture ( Preservative treatment)) |
- |
2000 |
|
- |
Cl-7.1(Dimensions -length) |
- |
250 |
|
- |
Cl-7.2(Thickness) |
- |
250 |
|
- |
Cl-7.3(Squareness) |
- |
250 |
|
- |
Cl-8.1, 8.2(Workmanship and finish) |
- |
250 |
|
- |
Cl-10.3(Moisture Content) |
- |
500 |
|
- |
Cl-10.4.1(Glue Adhesion in Dry State - Glue Shear Strength) |
- |
1000 |
|
- |
Cl-10.4.2(Glue Adhesion in Dry State - Adhesion of Plies) |
- |
500 |
|
- |
Cl-10.5, 10.5.1(Resistance to Water Test) |
- |
1000 |
|
- |
Cl-10.5.1.1(Water Resistance Test-Glue shear strength) |
- |
1000 |
|
- |
Cl-10.5.1.2(Water Resistance Test-Adhesion of plies) |
- |
1000 |
|
- |
Cl-10.6(Water resistance test (Concrete shuttering Plywood)) |
- |
500 |
|
- |
Cl-10.7.1, Table-2(Mycological Test- Glue shear strengt) |
- |
2000 |
|
- |
Cl-10.7.2(Mycological Test- Adhesion of plies) |
- |
500 |
|
- |
Cl-10.8(Tensile Strength) |
- |
2500 |
|
- |
Cl-10.9, Table-3 (i)(Along (parallel to the grain direction of the face veneer)) |
- |
1000 |
|
- |
Cl-10.9, Table-3 (ii)(Across (perpendicular to the grain direction of the face veneer)) |
- |
1000 |
|
- |
Cl-10.10, Table-4 (i) a(Wet Bending Strength -Modulus of Elasticity (MOE),- Average) |
- |
1000 |
|
- |
Cl-10.10, Table-4 (i) b(Wet Bending Strength -
Modulus of Elasticity (MOE),- Minimum individual) |
- |
1000 |
|
- |
Cl-10.11(Retention of Preservative) |
- |
2000 |
|
- |
Cl-10.12(Formaldehyde Content Test) |
- |
2000 |
|
- |
|
07 Sep, 2025 |
- Included w.e.f. 30.10.2024
Exclusion
Cl-10.13 (Steady-State Formaldehyde Emission Test)
Cl-10.5.2 (Water Resistance Test (Alternate method)) |
42 |
IS 710 (2024) |
MARINE PLYWOOD - SPECIFICATION (Third Revision) |
TYPE- BWP/ ALL SIZES AS PER IS |
15500 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Cl-4.1(Timber) |
- |
5000 |
|
CORE VENEER AND FACE VENEER |
Cl-4.2(Adhesive) |
- |
9500 |
|
- |
Cl-5.1(Veneers) |
- |
500 |
|
- |
Cl-5.2.1(Glueing) |
- |
200 |
|
- |
Cl -5.2.2(Thickness of Veneers) |
- |
200 |
|
- |
Cl - 5.2.3.1(Joint in Veneers) |
- |
200 |
|
- |
Cl - 5.2.3.2(Edge joints) |
- |
200 |
|
- |
Cl - 5.2.3.3(End joints) |
- |
200 |
|
- |
Cl - 5.2.3.4(Scarf joints) |
- |
200 |
|
- |
Cl - 5.2.4(Grain Direction) |
- |
200 |
|
- |
Cl-5.3(Treatment) |
- |
2000 |
|
- |
Cl-5.4(Moisture Content) |
- |
500 |
|
- |
Cl-6.1(Dimensions (length)) |
- |
250 |
|
- |
Cl-6.2(Thickness) |
- |
250 |
|
- |
Cl-6.3(Squareness) |
- |
250 |
|
- |
Cl-7.1, 7.2, 7.3, 7.4, 7.5 & 7.6(Workmanship and finish) |
- |
250 |
|
- |
Cl-9.3(Moisture Content) |
- |
500 |
|
- |
Cl-9.4.2(Glue Adhesion in Dry State- Adhesion of Plies) |
- |
500 |
|
- |
Cl-9.4.1(Glue Adhesion in Dry State- Glue Shear Strength -Average) |
- |
1500 |
|
- |
Cl-9.5.1.1(Glue Adhesion in Water Resistance - Glue Shear Strength -Average) |
- |
1500 |
|
- |
Cl-9.5.1.2(Water Resistance Test-Adhesion of plies) |
- |
500 |
|
- |
Cl-9.5.2(Water Resistance Test) |
- |
1000 |
|
- |
Cl-9.6(Tensile Strength-Along the grain) |
- |
1500 |
|
- |
Cl-9.7(Mycological Test -Adhesion) |
- |
2000 |
|
- |
Cl-9.8, Table-2(Static Bending Strength - Modulus of Elasticity - Along the Face Grain - Average) |
- |
1250 |
|
- |
Cl-9.8, Table-2(Static Bending Strength - Modulus of Elasticity - Along the Face Grain - Minimum Individual) |
- |
1250 |
|
- |
Cl-9.9, Table-3 (i) a(Wet Bending Strength- Modulus of Elasticity (MOE)- Average) |
- |
1250 |
|
- |
Cl-9.9, Table-3 (i) b(Wet Bending Strength- Modulus of Elasticity (MOE),-Minimum
individual) |
- |
1250 |
|
- |
Cl-9.10(Retention of Preservative) |
- |
2000 |
|
- |
Cl-9.11(Formaldehyde Content Test) |
- |
2000 |
|
- |
Cl-4.1(Timber) |
- |
500 |
|
- |
Cl-4.2(Adhesive) |
- |
9000 |
|
- |
Cl-5.1(Veneers) |
- |
500 |
|
- |
Cl-5.2.1(Glueing) |
- |
500 |
|
- |
Cl -5.2.2(Thickness of Veneers) |
- |
500 |
|
- |
Cl - 5.2.3.1(Joint in Veneers) |
- |
200 |
|
- |
Cl - 5.2.3.2(Edge joints) |
- |
200 |
|
- |
Cl - 5.2.3.3(End joints) |
- |
200 |
|
- |
Cl - 5.2.3.4(Scarf joints) |
- |
200 |
|
- |
Cl - 5.2.4(Grain Direction) |
- |
200 |
|
- |
Cl-5.3(Treatment) |
- |
200 |
|
- |
Cl-5.4(Moisture Content) |
- |
1000 |
|
- |
Cl-6.1(Dimensions (length)) |
- |
500 |
|
- |
Cl-6.2(Thickness) |
- |
200 |
|
- |
Cl-6.3(Squareness) |
- |
200 |
|
- |
Cl-7.1, 7.2, 7.3, 7.4, 7.5 & 7.6(Workmanship and finish) |
- |
200 |
|
- |
Cl-9.3(Moisture Content) |
- |
1500 |
|
- |
Cl-9.4.2(Glue Adhesion in Dry State- Adhesion of Plies) |
- |
200 |
|
- |
Cl-9.4.1(Glue Adhesion in Dry State- Glue Shear Strength -Average) |
- |
200 |
|
- |
Cl-9.5.1.1(Glue Adhesion in Water Resistance - Glue Shear Strength -Average) |
- |
500 |
|
- |
Cl-9.5.1.2(Water Resistance Test-Adhesion of plies) |
- |
500 |
|
- |
Cl-9.5.2(Water Resistance Test) |
- |
1000 |
|
- |
Cl-9.6(Tensile Strength-Along the grain) |
- |
1500 |
|
- |
Cl-9.7(Mycological Test -Adhesion) |
- |
1500 |
|
- |
Cl-9.8, Table-2(Static Bending Strength - Modulus of Elasticity - Along the Face Grain - Average) |
- |
1500 |
|
- |
Cl-9.8, Table-2(Static Bending Strength - Modulus of Elasticity - Along the Face Grain - Minimum Individual) |
- |
1500 |
|
- |
Cl-9.9, Table-3 (i) a(Wet Bending Strength- Modulus of Elasticity (MOE)- Average) |
- |
1500 |
|
- |
Cl-9.9, Table-3 (i) b(Wet Bending Strength- Modulus of Elasticity (MOE),-Minimum
individual) |
- |
1500 |
|
- |
Cl-9.10(Retention of Preservative) |
- |
500 |
|
- |
Cl-9.11(Formaldehyde Content Test) |
- |
2500 |
|
- |
Cl-9.4.2(Adhesion of Plies) |
- |
500 |
|
- |
5.1.1(Defects in veneers) |
- |
200 |
|
- |
|
07 Sep, 2025 |
- Included w.e.f 24.10.2024
Excluding Cl 9.12 (Steady state formaldehyde emission test) |
43 |
IS 303 (2024) |
Plywood for General Purposes — Specification (Fourth Revision) |
GRADE-MR/BWR/BWP/ TYPE- AA/AB/BB/ SIZE- ALL SIZES |
10000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Cl-5.1(Classification by appearance) |
- |
500 |
|
- |
Cl-5.2, Table- 1 (i)(Blister) |
- |
100 |
|
- |
Cl-5.2, Table- 1 (ii)(Checks) |
- |
100 |
|
- |
Cl-5.2, Table- 1 (iii)(Discolouration) |
- |
100 |
|
- |
Cl-5.2, Table- 1 (iv)(Dote) |
- |
100 |
|
- |
Cl-5.2, Table- 1 (v)(Insect hole) |
- |
100 |
|
- |
Cl-5.2, Table- 1 (vi)(Joints) |
- |
100 |
|
- |
Cl-5.2, Table- 1 (vii)(Knots (dead)) |
- |
100 |
|
- |
Cl-5.2, Table- 1 (viii)(Pin knots (dead)) |
- |
100 |
|
- |
Cl-5.2, Table- 1 (ix)(Pin knots (live)) |
- |
100 |
|
- |
Cl-5.2, Table- 1 (x)(Knots (tight)) |
- |
100 |
|
- |
Cl-5.2, Table- 1 (xi)(Patches) |
- |
100 |
|
- |
Cl-5.2, Table- 1 (xii)(Splits) |
- |
100 |
|
- |
Cl-5.2, Table- 1 (xiii)(Swirl) |
- |
100 |
|
- |
Cl-5.2, Table-2(Maximum Number of Categories of Permissible Defects, per m2) |
- |
100 |
|
- |
Cl-6.1(Timber) |
- |
5000 |
|
for Face Veneer and Core Veneer Only |
Cl-6.2(Adhesive) |
- |
9000 |
|
Grade -MR- 8500, Grade -BWR-9000, Grade -BWP-9500/- |
Cl-7.2.1(Thickness of veneers) |
- |
100 |
|
- |
Cl-7.2.3(Grain Direction) |
- |
100 |
|
- |
Cl-7.2.5.1(Gaps in cores and cross-bands) |
- |
100 |
|
- |
Cl-7.2.5.2(Splits) |
- |
100 |
|
- |
Cl-7.2.5.3(Overlap) |
- |
100 |
|
- |
Cl-8.1(Dimensions -length) |
- |
250 |
|
- |
Cl-8.2(Thickness of the plywood boards) |
- |
250 |
|
- |
Cl-8.3(Squareness) |
- |
250 |
|
- |
Cl-11.3.1, 11.3.1.1(Water Resistance Test) |
- |
2000 |
|
- |
Cl-11.3.2(Mycological Test) |
- |
2000 |
|
- |
Cl-11.4(Moisture Content) |
- |
500 |
|
- |
Cl-11.5, Table 4(Static Bending Strength - Modulus of Elasticity - Along the Face Grain - Average) |
- |
2500 |
|
- |
Cl-11.5, Table 4(Static Bending Strength - Modulus of Elasticity - Along the Face Grain - Minimum Individual) |
- |
2500 |
|
- |
Cl-11.6(Formaldehyde Content Test) |
- |
2000 |
|
- |
Cl-5.1(Classification by appearance) |
- |
200 |
|
- |
Cl-5.2, Table- 1 (i)(Blister) |
- |
200 |
|
- |
Cl-5.2, Table- 1 (ii)(Checks) |
- |
200 |
|
- |
Cl-5.2, Table- 1 (iii)(Discolouration) |
- |
200 |
|
- |
Cl-5.2, Table- 1 (iv)(Dote) |
- |
200 |
|
- |
Cl-5.2, Table- 1 (v)(Insect hole) |
- |
200 |
|
- |
Cl-5.2, Table- 1 (vi)(Joints) |
- |
200 |
|
- |
Cl-5.2, Table- 1 (vii)(Knots (dead)) |
- |
200 |
|
- |
Cl-5.2, Table- 1 (viii)(Pin knots (dead)) |
- |
200 |
|
- |
Cl-5.2, Table- 1 (ix)(Pin knots (live)) |
- |
200 |
|
- |
Cl-5.2, Table- 1 (x)(Knots (tight)) |
- |
200 |
|
- |
Cl-5.2, Table- 1 (xi)(Patches) |
- |
200 |
|
- |
Cl-5.2, Table- 1 (xii)(Splits) |
- |
200 |
|
- |
Cl-5.2, Table- 1 (xiii)(Swirl) |
- |
200 |
|
- |
Cl-5.2, Table-2(Maximum Number of Categories of Permissible Defects, per m2) |
- |
200 |
|
- |
Cl-6.1(Timber) |
- |
200 |
|
- |
Cl-6.2(Adhesive) |
- |
8500 |
|
- |
Cl-7.2.1(Thickness of veneers) |
- |
200 |
|
- |
Cl-7.2.3(Grain Direction) |
- |
200 |
|
- |
Cl-7.2.5.1(Gaps in cores and cross-bands) |
- |
200 |
|
- |
Cl-7.2.5.2(Splits) |
- |
200 |
|
- |
Cl-7.2.5.3(Overlap) |
- |
200 |
|
- |
Cl-8.1(Dimensions -length) |
- |
200 |
|
- |
Cl-8.2(Thickness of the plywood boards) |
- |
200 |
|
- |
Cl-8.3(Squareness) |
- |
2000 |
|
- |
Cl-11.3.1, 11.3.1.1(Water Resistance Test) |
- |
2000 |
|
- |
Cl-11.3.2(Mycological Test) |
- |
2000 |
|
- |
Cl-11.4(Moisture Content) |
- |
1000 |
|
- |
Cl-11.5, Table 4(Static Bending Strength - Modulus of Elasticity - Along the Face Grain - Average) |
- |
500 |
|
- |
Cl-11.5, Table 4(Static Bending Strength - Modulus of Elasticity - Along the Face Grain - Minimum Individual) |
- |
500 |
|
- |
Cl-11.6(Formaldehyde Content Test) |
- |
3000 |
|
- |
Cl-5.1(Classification by appearance) |
- |
500 |
|
- |
Cl-5.2, Table- 1 (i)(Blister) |
- |
500 |
|
- |
Cl-5.2, Table- 1 (ii)(Checks) |
- |
500 |
|
- |
Cl-5.2, Table- 1 (iii)(Discolouration) |
- |
500 |
|
- |
Cl-5.2, Table- 1 (iv)(Dote) |
- |
500 |
|
- |
Cl-5.2, Table- 1 (v)(Insect hole) |
- |
500 |
|
- |
Cl-5.2, Table- 1 (vi)(Joints) |
- |
500 |
|
- |
Cl-5.2, Table- 1 (vii)(Knots (dead)) |
- |
500 |
|
- |
Cl-5.2, Table- 1 (viii)(Pin knots (dead)) |
- |
500 |
|
- |
Cl-5.2, Table- 1 (ix)(Pin knots (live)) |
- |
500 |
|
- |
Cl-5.2, Table- 1 (x)(Knots (tight)) |
- |
500 |
|
- |
Cl-5.2, Table- 1 (xi)(Patches) |
- |
500 |
|
- |
Cl-5.2, Table- 1 (xii)(Splits) |
- |
500 |
|
- |
Cl-5.2, Table- 1 (xiii)(Swirl) |
- |
500 |
|
- |
Cl-5.2, Table-2(Maximum Number of Categories of Permissible Defects, per m2) |
- |
500 |
|
- |
Cl-6.1(Timber) |
- |
500 |
|
- |
Cl-6.2(Adhesive) |
- |
9500 |
|
- |
Cl-7.2.1(Thickness of veneers) |
- |
200 |
|
- |
Cl-7.2.3(Grain Direction) |
- |
200 |
|
- |
Cl-7.2.5.1(Gaps in cores and cross-bands) |
- |
200 |
|
- |
Cl-7.2.5.2(Splits) |
- |
200 |
|
- |
Cl-7.2.5.3(Overlap) |
- |
200 |
|
- |
Cl-8.1(Dimensions -length) |
- |
200 |
|
- |
Cl-8.2(Thickness of the plywood boards) |
- |
200 |
|
- |
Cl-8.3(Squareness) |
- |
2000 |
|
- |
Cl-11.3.1, 11.3.1.1(Water Resistance Test) |
- |
1500 |
|
- |
Cl-11.3.2(Mycological Test) |
- |
1500 |
|
- |
Cl-11.4(Moisture Content) |
- |
1000 |
|
- |
Cl-11.5, Table 4(Static Bending Strength - Modulus of Elasticity - Along the Face Grain - Average) |
- |
1500 |
|
- |
Cl-11.5, Table 4(Static Bending Strength - Modulus of Elasticity - Along the Face Grain - Minimum Individual) |
- |
1500 |
|
- |
Cl-11.6(Formaldehyde Content Test) |
- |
3000 |
|
- |
|
07 Sep, 2025 |
- Included w.e.f. 30.10.2024
Exclusion
Cl-11.7 (Steady-State Formaldehyde Emission Test) |
44 |
IS 1729 (2023) |
SAND CAST IRON SPIGOT AND SOCKET PIPES, FITTINGS AND ACCESSORIES � SPECIFICATION |
50-150 MM ALL SIZE |
9000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Cl-4.2, (i)(Supply of material) |
- |
100 |
|
- |
Cl-5.1(Manufacture of cast iron) |
- |
800 |
|
- |
Cl-5.2(Screws, bolts and fittings) |
- |
200 |
|
- |
Cl-5.3(The pipes, fittings and accessories) |
- |
200 |
|
- |
Cl-5.4(The pipes and fittings) |
- |
200 |
|
- |
Cl-5.5(Brinell hardness test) |
- |
500 |
|
- |
Cl-6(Hammer Test) |
- |
500 |
|
- |
Cl-7.1(Leakage Test) |
- |
1500 |
|
- |
Cl-8(Range of nominal diameters) |
- |
100 |
|
- |
Cl-9, Table- 1 (a), (i)(Pipe- Internal dia (Min), A) |
- |
100 |
|
- |
Cl-9, Table- 1 (a), (ii)(Pipe- External dia (Max), B) |
- |
100 |
|
- |
Cl-9, Table- 1 (a), (iii)(Pipe- Wall thickness, C) |
- |
100 |
|
- |
Cl-9, Table- 1 (a), (iv)(Pipe- Tolerance on, C) |
- |
100 |
|
- |
Cl-9, Table- 1 (a), (v)(Pipe- Dia of spigot bead (Max), E) |
- |
100 |
|
- |
Cl-9, Table- 1 (b), (i)(Socket-Internal dia (Min), F) |
- |
100 |
|
- |
Cl-9, Table- 1 (b), (ii)(Socket-External dia (Max), G) |
- |
100 |
|
- |
Cl-9, Table- 1 (b), (iii)(Socket-Thickness, H) |
- |
100 |
|
- |
Cl-9, Table- 1 (b), (iv)(Socket -Tolerance on, H) |
- |
100 |
|
- |
Cl-9, Table- 1 (b), (v)(Socket- Internal depth, J) |
- |
100 |
|
- |
Cl-9, Table- 1 (b), (vi)(Socket- Outside dia over beads (Min), K) |
- |
100 |
|
- |
Cl-9, Table- 1 (b), (vii)(Socket- Ears length of flange, U) |
- |
100 |
|
- |
Cl-9, Table- 1 (b), (viii)(Socket- Centre to centre hole, V) |
- |
100 |
|
- |
Cl-9.3 (i)(Tolerance on length-Pipes) |
- |
100 |
|
- |
Cl-9.3 (ii)(Tolerance on length-Fittings) |
- |
100 |
|
- |
Cl-9.5(Tolerances for dimensions) |
- |
100 |
|
- |
Cl-9.6(Internal depth of socket) |
- |
100 |
|
- |
Cl-10(Coatings Test) |
- |
500 |
|
- |
Cl-11(Marking) |
- |
100 |
|
- |
Cl-4.2, (i)(Supply of material) |
- |
100 |
|
- |
Cl-5.1(Manufacture of cast iron) |
- |
800 |
|
- |
Cl-5.2(Screws, bolts and fittings) |
- |
100 |
|
- |
Cl-5.3(The pipes, fittings and accessories) |
- |
100 |
|
- |
Cl-5.4(The pipes and fittings) |
- |
100 |
|
- |
Cl-5.5(Brinell hardness test) |
- |
500 |
|
- |
Cl-6(Hammer Test) |
- |
500 |
|
- |
Cl-7.1(Leakage Test) |
- |
1500 |
|
- |
Cl-8(Range of nominal diameters) |
- |
100 |
|
- |
Cl-9, Table- 1 (a), (i)(Pipe- Internal dia (Min), A) |
- |
100 |
|
- |
Cl-9, Table- 1 (a), (ii)(Pipe- External dia (Max), B) |
- |
100 |
|
- |
Cl-9, Table- 1 (a), (iii)(Pipe- Wall thickness, C) |
- |
100 |
|
- |
Cl-9, Table- 1 (a), (iv)(Pipe- Tolerance on, C) |
- |
100 |
|
- |
Cl-9, Table- 1 (a), (v)(Pipe- Dia of spigot bead (Max), E) |
- |
100 |
|
- |
Cl-9, Table- 1 (b), (i)(Socket-Internal dia (Min), F) |
- |
100 |
|
- |
Cl-9, Table- 1 (b), (ii)(Socket-External dia (Max), G) |
- |
100 |
|
- |
Cl-9, Table- 1 (b), (iii)(Socket-Thickness, H) |
- |
100 |
|
- |
Cl-9, Table- 1 (b), (iv)(Socket -Tolerance on, H) |
- |
100 |
|
- |
Cl-9, Table- 1 (b), (v)(Socket- Internal depth, J) |
- |
100 |
|
- |
Cl-9, Table- 1 (b), (vi)(Socket- Outside dia over beads (Min), K) |
- |
100 |
|
- |
Cl-9, Table- 1 (b), (vii)(Socket- Ears length of flange, U) |
- |
100 |
|
- |
Cl-9, Table- 1 (b), (viii)(Socket- Centre to centre hole, V) |
- |
100 |
|
- |
Cl-9.3 (i)(Tolerance on length-Pipes) |
- |
100 |
|
- |
Cl-9.3 (ii)(Tolerance on length-Fittings) |
- |
100 |
|
- |
Cl-9.5(Tolerances for dimensions) |
- |
100 |
|
- |
Cl-9.6(Internal depth of socket) |
- |
100 |
|
- |
Cl-10(Coatings Test) |
- |
500 |
|
- |
Cl-11(Marking) |
- |
100 |
|
- |
Cl-4.2, (i)(Supply of material) |
- |
100 |
|
- |
Cl-5.1(Manufacture of cast iron) |
- |
1500 |
|
- |
Cl-5.2(Screws, bolts and fittings) |
- |
500 |
|
- |
Cl-5.3(The pipes, fittings and accessories) |
- |
200 |
|
- |
Cl-5.4(The pipes and fittings) |
- |
200 |
|
- |
Cl-5.5(Brinell hardness test) |
- |
500 |
|
- |
Cl-6(Hammer Test) |
- |
500 |
|
- |
Cl-7.1(Leakage Test) |
- |
500 |
|
- |
Cl-8(Range of nominal diameters) |
- |
500 |
|
- |
Cl-9, Table- 1 (a), (i)(Pipe- Internal dia (Min), A) |
- |
200 |
|
- |
Cl-9, Table- 1 (a), (ii)(Pipe- External dia (Max), B) |
- |
200 |
|
- |
Cl-9, Table- 1 (a), (iii)(Pipe- Wall thickness, C) |
- |
200 |
|
- |
Cl-9, Table- 1 (a), (iv)(Pipe- Tolerance on, C) |
- |
200 |
|
- |
Cl-9, Table- 1 (a), (v)(Pipe- Dia of spigot bead (Max), E) |
- |
200 |
|
- |
Cl-9, Table- 1 (b), (i)(Socket-Internal dia (Min), F) |
- |
200 |
|
- |
Cl-9, Table- 1 (b), (ii)(Socket-External dia (Max), G) |
- |
200 |
|
- |
Cl-9, Table- 1 (b), (iii)(Socket-Thickness, H) |
- |
200 |
|
- |
Cl-9, Table- 1 (b), (iv)(Socket -Tolerance on, H) |
- |
100 |
|
- |
Cl-9, Table- 1 (b), (v)(Socket- Internal depth, J) |
- |
100 |
|
- |
Cl-9, Table- 1 (b), (vi)(Socket- Outside dia over beads (Min), K) |
- |
100 |
|
- |
Cl-9, Table- 1 (b), (vii)(Socket- Ears length of flange, U) |
- |
100 |
|
- |
Cl-9, Table- 1 (b), (viii)(Socket- Centre to centre hole, V) |
- |
100 |
|
- |
Cl-9.3 (i)(Tolerance on length-Pipes) |
- |
100 |
|
- |
Cl-9.3 (ii)(Tolerance on length-Fittings) |
- |
100 |
|
- |
Cl-9.5(Tolerances for dimensions) |
- |
100 |
|
- |
Cl-9.6(Internal depth of socket) |
- |
100 |
|
- |
Cl-10(Coatings Test) |
- |
100 |
|
- |
Cl-11(Marking) |
- |
100 |
|
- |
Cl-4.2, (i)(Supply of material) |
- |
100 |
|
- |
Cl-5.1(Manufacture of cast iron) |
- |
100 |
|
- |
Cl-5.2(Screws, bolts and fittings) |
- |
100 |
|
- |
Cl-5.3(The pipes, fittings and accessories) |
- |
100 |
|
- |
Cl-5.4(The pipes and fittings) |
- |
100 |
|
- |
Cl-5.5(Brinell hardness test) |
- |
500 |
|
- |
Cl-6(Hammer Test) |
- |
200 |
|
- |
Cl-7.1(Leakage Test) |
- |
1500 |
|
- |
Cl-8(Range of nominal diameters) |
- |
100 |
|
- |
Cl-9, Table- 1 (a), (i)(Pipe- Internal dia (Min), A) |
- |
100 |
|
- |
Cl-9, Table- 1 (a), (ii)(Pipe- External dia (Max), B) |
- |
100 |
|
- |
Cl-9, Table- 1 (a), (iii)(Pipe- Wall thickness, C) |
- |
100 |
|
- |
Cl-9, Table- 1 (a), (iv)(Pipe- Tolerance on, C) |
- |
100 |
|
- |
Cl-9, Table- 1 (a), (v)(Pipe- Dia of spigot bead (Max), E) |
- |
100 |
|
- |
Cl-9, Table- 1 (b), (i)(Socket-Internal dia (Min), F) |
- |
100 |
|
- |
Cl-9, Table- 1 (b), (ii)(Socket-External dia (Max), G) |
- |
100 |
|
- |
Cl-9, Table- 1 (b), (iii)(Socket-Thickness, H) |
- |
100 |
|
- |
Cl-9, Table- 1 (b), (iv)(Socket -Tolerance on, H) |
- |
100 |
|
- |
Cl-9, Table- 1 (b), (v)(Socket- Internal depth, J) |
- |
100 |
|
- |
Cl-9, Table- 1 (b), (vi)(Socket- Outside dia over beads (Min), K) |
- |
100 |
|
- |
Cl-9, Table- 1 (b), (vii)(Socket- Ears length of flange, U) |
- |
100 |
|
- |
Cl-9, Table- 1 (b), (viii)(Socket- Centre to centre hole, V) |
- |
100 |
|
- |
Cl-9.3 (i)(Tolerance on length-Pipes) |
- |
100 |
|
- |
Cl-9.3 (ii)(Tolerance on length-Fittings) |
- |
100 |
|
- |
Cl-9.5(Tolerances for dimensions) |
- |
100 |
|
- |
Cl-9.6(Internal depth of socket) |
- |
100 |
|
- |
Cl-10(Coatings Test) |
- |
700 |
|
- |
Cl-11(Marking) |
- |
100 |
|
- |
|
07 Sep, 2025 |
- Included w.e.f 24.10.2024 |
45 |
IS 1536 (2023) |
Centrifugally cast (spun) iron pressure pipes for water, gas and sewage � Specification |
ALL CLASS / 80 DN TO 1000 DN |
9000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Cl-9.1(Rubber gasket materials) |
- |
500 |
|
- |
Cl-9.2(Rubber gasket materials) |
- |
500 |
|
- |
Cl-9.3(Rubber gasket materials) |
- |
500 |
|
- |
"Cl- 11.1,11.2, 11.4 Annex A"(Ring Test (for pipes cast in metal moulds)) |
- |
2000 |
|
- |
"Cl- 11.1,11.2, 11.4, Annex A"(Tensile Test) |
- |
1500 |
|
- |
Cl- 11.3,6.2,11.4(Brinell Hardness Test) |
- |
800 |
|
- |
"Cl- 12.1, 12.2 Table-1,2"(Hydrostatic Test) |
- |
2000 |
|
- |
"Cl- 13 to 14, Table 3 to 11"(Sizes, Dimensions & Tolerances) |
- |
500 |
|
- |
Cl- 15.1 & 15.2(Coating) |
- |
500 |
|
- |
Cl-9.1(Rubber gasket materials) |
- |
200 |
|
- |
"Cl- 11.1,11.2, 11.4 Annex A"(Ring Test (for pipes cast in metal moulds)) |
- |
500 |
|
- |
"Cl- 11.1,11.2, 11.4, Annex A"(Tensile Test) |
- |
1500 |
|
- |
Cl- 11.3,6.2,11.4(Brinell Hardness Test) |
- |
800 |
|
- |
"Cl- 12.1, 12.2 Table-1,2"(Hydrostatic Test) |
- |
2000 |
|
- |
"Cl- 13 to 14, Table 3 to 11"(Sizes, Dimensions & Tolerances) |
- |
500 |
|
- |
Cl- 15.1 & 15.2(Coating) |
- |
500 |
|
- |
Cl-9.2(Rubber gasket materials) |
- |
200 |
|
- |
Cl-9.3(Rubber gasket materials) |
- |
500 |
|
- |
Cl-9.1(Rubber gasket materials) |
- |
500 |
|
- |
"Cl- 11.1,11.2, 11.4 Annex A"(Ring Test (for pipes cast in metal moulds)) |
- |
200 |
|
- |
"Cl- 11.1,11.2, 11.4, Annex A"(Tensile Test) |
- |
1500 |
|
- |
Cl- 11.3,6.2,11.4(Brinell Hardness Test) |
- |
500 |
|
- |
"Cl- 12.1, 12.2 Table-1,2"(Hydrostatic Test) |
- |
2000 |
|
- |
"Cl- 13 to 14, Table 3 to 11"(Sizes, Dimensions & Tolerances) |
- |
500 |
|
- |
Cl- 15.1 & 15.2(Coating) |
- |
1000 |
|
- |
Cl-9.2(Rubber gasket materials) |
- |
500 |
|
- |
Cl-9.3(Rubber gasket materials) |
- |
500 |
|
- |
|
07 Sep, 2025 |
- Included w.e.f. 25.09.2024 |
46 |
IS 2191 : Part 1 (2022) |
WOODEN FLUSH DOOR SHUTTERS CELLULAR TUBULAR AND HOLLOW CORE TYPE SPECIFICATION PART 1 PLYWOOD FACE PANELS Fifth Revision |
grade - MR/BWP, Type-CD/CN,HD/HN,TD/TN |
30000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Cl-5(Sizes) |
- |
400 |
|
- |
Cl-6.1.1(Species of timber) |
- |
1500 |
|
- |
Cl-6.3(Cross-Bands) |
- |
1500 |
|
- |
Cl-6.4.1(Commercial face veneers) |
- |
1500 |
|
- |
Cl-6.4.2(Decorative face veneers) |
- |
1500 |
|
- |
Cl-6.7(Particle Board) |
- |
1500 |
|
- |
Cl-6.8(Laminated veneer lumber (LVL), veneer laminated lumber (VLL), Medium Density Fibre (MDF)) |
- |
1500 |
|
- |
Cl-11.1(Dimensions and Squareness Test) |
- |
500 |
|
- |
Cl-11.2(General Flatness Test) |
- |
1000 |
|
- |
Cl-11.3(Local Planeness Test) |
- |
1000 |
|
- |
Cl-11.4(Impact Indentation Test) |
- |
1000 |
|
- |
Cl-11.5(Flexure Test) |
- |
1500 |
|
- |
Cl-11.6(Edge Loading Test) |
- |
1000 |
|
- |
Cl-11.7(Shock Resistance Test) |
- |
1000 |
|
- |
Cl-11.8(Buckling Resistance Test) |
- |
1500 |
|
- |
Cl-11.9(Slamming Test) |
- |
1500 |
|
- |
Cl-11.10(Misuse Test) |
- |
1500 |
|
- |
Cl-11.11(Varying Humidity Test) |
- |
6000 |
|
- |
Cl-11.12(End Immersion Test) |
- |
1500 |
|
- |
Cl-11.13(Knife Test) |
- |
1000 |
|
- |
Cl-11.14(Glue Adhesion Test) |
- |
1500 |
|
- |
Cl-11.15(Screw Withdrawal Resistance Test) |
- |
2000 |
|
- |
Cl-12.2(Sample Size) |
- |
100 |
|
- |
Cl-14(Marking) |
- |
100 |
|
- |
Cl-5(Sizes) |
- |
500 |
|
- |
Cl-6.1.1(Species of timber) |
- |
500 |
|
- |
Cl-6.3(Cross-Bands) |
- |
500 |
|
- |
Cl-6.4.1(Commercial face veneers) |
- |
500 |
|
- |
Cl-6.4.2(Decorative face veneers) |
- |
500 |
|
- |
Cl-6.7(Particle Board) |
- |
1000 |
|
- |
Cl-6.8(Laminated veneer lumber (LVL), veneer laminated lumber (VLL), Medium Density Fibre (MDF)) |
- |
1000 |
|
- |
Cl-11.1(Dimensions and Squareness Test) |
- |
500 |
|
- |
Cl-11.2(General Flatness Test) |
- |
1000 |
|
- |
Cl-11.3(Local Planeness Test) |
- |
500 |
|
- |
Cl-11.4(Impact Indentation Test) |
- |
1000 |
|
- |
Cl-11.5(Flexure Test) |
- |
2000 |
|
- |
Cl-11.6(Edge Loading Test) |
- |
2000 |
|
- |
Cl-11.7(Shock Resistance Test) |
- |
1500 |
|
- |
Cl-11.8(Buckling Resistance Test) |
- |
1500 |
|
- |
Cl-11.9(Slamming Test) |
- |
1000 |
|
- |
Cl-11.10(Misuse Test) |
- |
1000 |
|
- |
Cl-11.11(Varying Humidity Test) |
- |
7000 |
|
- |
Cl-11.12(End Immersion Test) |
- |
2000 |
|
- |
Cl-11.13(Knife Test) |
- |
500 |
|
- |
Cl-11.14(Glue Adhesion Test) |
- |
1000 |
|
- |
Cl-11.15(Screw Withdrawal Resistance Test) |
- |
2000 |
|
- |
Cl-12.2(Sample Size) |
- |
100 |
|
- |
Cl-14(Marking) |
- |
100 |
|
- |
Cl-6.1.2(Moisture content of timber) |
- |
1000 |
|
- |
Cl-9(Workmanship and Finish) |
- |
200 |
|
- |
Cl-6.1.3(Defects) |
- |
200 |
|
- |
Cl-5(Sizes) |
- |
500 |
|
- |
Cl-6.1.1(Species of timber) |
- |
1000 |
|
- |
Cl-6.3(Cross-Bands) |
- |
1000 |
|
- |
Cl-6.4.1(Commercial face veneers) |
- |
1000 |
|
- |
Cl-6.4.2(Decorative face veneers) |
- |
800 |
|
- |
Cl-6.7(Particle Board) |
- |
7000 |
|
- |
Cl-6.8(Laminated veneer lumber (LVL), veneer laminated lumber (VLL), Medium Density Fibre (MDF)) |
- |
500 |
|
- |
Cl-11.1(Dimensions and Squareness Test) |
- |
500 |
|
- |
Cl-11.2(General Flatness Test) |
- |
1000 |
|
- |
Cl-11.3(Local Planeness Test) |
- |
1000 |
|
- |
Cl-11.4(Impact Indentation Test) |
- |
1000 |
|
- |
Cl-11.5(Flexure Test) |
- |
2000 |
|
- |
Cl-11.6(Edge Loading Test) |
- |
1500 |
|
- |
Cl-11.7(Shock Resistance Test) |
- |
2000 |
|
- |
Cl-11.8(Buckling Resistance Test) |
- |
1500 |
|
- |
Cl-11.9(Slamming Test) |
- |
2000 |
|
- |
Cl-11.10(Misuse Test) |
- |
1000 |
|
- |
Cl-11.11(Varying Humidity Test) |
- |
7000 |
|
- |
Cl-11.12(End Immersion Test) |
- |
2000 |
|
- |
Cl-11.13(Knife Test) |
- |
1000 |
|
- |
Cl-11.14(Glue Adhesion Test) |
- |
1000 |
|
- |
Cl-11.15(Screw Withdrawal Resistance Test) |
- |
1500 |
|
- |
Cl-12.2(Sample Size) |
- |
200 |
|
- |
Cl-14(Marking) |
- |
200 |
|
- |
Cl-6.1.2(Moisture content of timber) |
- |
500 |
|
- |
Cl-9(Workmanship and Finish) |
- |
200 |
|
- |
Cl-6.1.3(Defects) |
- |
200 |
|
- |
|
07 Sep, 2025 |
- Included w.e.f 12.09.2024 |
47 |
IS 1239 : Part 1 (2004) |
Steel Tubes, Tubulars and Other Wrought Steel Fittings : Part 1 Steel Tubes (BI-LINGUAL) |
ALL TYPES |
9000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
12 AND AS PER IS 4736(UNIFORMITY OF ZINC COATING) |
- |
500 |
|
- |
12 AND AS PER IS 4736(MASS OF ZINC COATING) |
- |
0 |
|
- |
6.2 AND AS PER IS 513(NITROGEN) |
- |
1000 |
|
- |
6.2 AND AS PER IS 513(MICRO ALLOY) |
- |
100 |
|
- |
6.2 AND AS PER IS 513(ALUMINIUM) |
- |
500 |
|
- |
6.2 AND AS PER IS 513(SILICON) |
- |
500 |
|
- |
6.2 AND AS PER IS 513(MANGANESE) |
- |
500 |
|
- |
6.2 AND AS PER IS 513(PHOSPHORUS) |
- |
500 |
|
- |
6.2 AND AS PER IS 513(SULPHUR) |
- |
500 |
|
- |
6.2 AND AS PER IS 513(CARBON) |
- |
500 |
|
- |
6.2 AND AS PER IS 10748(COPPER) |
- |
500 |
|
- |
6.2 AND AS PER IS 10748(NITROGEN) |
- |
500 |
|
- |
6.2 AND AS PER IS 10748(MICRO ALLOY) |
- |
500 |
|
- |
6.2 AND AS PER IS 10748(ALUMINIUM) |
- |
500 |
|
- |
6.2 AND AS PER IS 10748(SILICON) |
- |
500 |
|
- |
6.2 AND AS PER IS 10748(CARBON EQUIVALENT) |
- |
500 |
|
- |
6.2 AND AS PER IS 10748(MANGANESE) |
- |
500 |
|
- |
6.2 AND AS PER IS 10748(PHOSPHORUS) |
- |
500 |
|
- |
6.2 AND AS PER IS 10748(SULPHUR) |
- |
500 |
|
- |
6.2 AND AS PER IS 10748(CARBON) |
- |
500 |
|
- |
Clause - 6.1.1, Table-1( ALUMINIUM) |
- |
500 |
|
- |
Clause - 6.1.1, Table-1(SILICON) |
- |
500 |
|
- |
Clause - 6.1.1, Table-1(NITROGEN) |
- |
500 |
|
- |
Clause - 6.1.1, Table-1(MANGANESE) |
- |
500 |
|
- |
Clause - 6.1.1, Table-1(PHOSPHURS) |
- |
500 |
|
- |
Clause - 6.1.1, Table-1(SULPHUR) |
- |
500 |
|
- |
Clause - 6.1.1, Table-1( CARBON) |
- |
500 |
|
- |
12 AND AS PER IS 4736(UNIFORMITY OF ZINC COATING) |
- |
500 |
|
- |
12 AND AS PER IS 4736(MASS OF ZINC COATING) |
- |
500 |
|
- |
6.2 AND AS PER IS 513(NITROGEN) |
- |
500 |
|
- |
6.2 AND AS PER IS 513(MICRO ALLOY) |
- |
500 |
|
- |
6.2 AND AS PER IS 513(ALUMINIUM) |
- |
500 |
|
- |
6.2 AND AS PER IS 513(SILICON) |
- |
500 |
|
- |
6.2 AND AS PER IS 513(MANGANESE) |
- |
500 |
|
- |
6.2 AND AS PER IS 513(PHOSPHORUS) |
- |
500 |
|
- |
6.2 AND AS PER IS 513(SULPHUR) |
- |
500 |
|
- |
6.2 AND AS PER IS 513(CARBON) |
- |
500 |
|
- |
6.2 AND AS PER IS 10748(COPPER) |
- |
500 |
|
- |
6.2 AND AS PER IS 10748(NITROGEN) |
- |
500 |
|
- |
6.2 AND AS PER IS 10748(MICRO ALLOY) |
- |
500 |
|
- |
6.2 AND AS PER IS 10748(ALUMINIUM) |
- |
500 |
|
- |
6.2 AND AS PER IS 10748(SILICON) |
- |
500 |
|
- |
6.2 AND AS PER IS 10748(CARBON EQUIVALENT) |
- |
500 |
|
- |
6.2 AND AS PER IS 10748(MANGANESE) |
- |
500 |
|
- |
6.2 AND AS PER IS 10748(PHOSPHORUS) |
- |
500 |
|
- |
6.2 AND AS PER IS 10748(SULPHUR) |
- |
500 |
|
- |
6.2 AND AS PER IS 10748(CARBON) |
- |
500 |
|
- |
6.1.1(MANGANESE) |
- |
500 |
|
- |
6.1.1(PHOSPHORUS) |
- |
500 |
|
- |
6.1.1(SULPHUR) |
- |
500 |
|
- |
6.1.1(CARBON) |
- |
500 |
|
- |
Cl. 6.1.1, table1 of IS 1239(Part1)(Phosphorus- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
500 |
|
- |
Cl. 6.1.1, table1 of IS 1239(Part1)(Sulphur- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
500 |
|
- |
Cl. 6.1.1, table1 of IS 1239(Part1)(Manganese- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
500 |
|
- |
Cl. 6.1.1, table1 of IS 1239(Part1)(Carbon- IS 228 and relevant parts or any other established Instrumental/Chemical method.) |
- |
500 |
|
- |
Cl. 15(Workmanship) |
- |
100 |
|
- |
Cl. 14.3(Flattening test (Over 50 mm NB)) |
- |
500 |
|
- |
Cl. 14.2(Bend Test (uto and including 50 mm NB)) |
- |
500 |
|
- |
Cl. 14.1.1(Elongation) |
- |
200 |
|
- |
Cl. 14.1(Tensile Strength) |
- |
1000 |
|
- |
Cl. 3.3, 10.2(Plain End) |
- |
100 |
|
- |
Cl. 11(Length) |
- |
100 |
|
- |
Cl. 8, 9 Table 3,4 & 5(Mass of Tube) |
- |
200 |
|
- |
Cl. 6.5(Height of Internal Fin) |
- |
100 |
|
- |
Cl. 8, 9 Table 3,4 & 5(Thickness) |
- |
100 |
|
- |
Cl. 8 Table 3,4 & 5(Outside Diameter) |
- |
100 |
|
- |
Clause 14.1.1(Elongation Percent) |
- |
100 |
|
- |
Clause 11.3(Approximate Length) |
- |
100 |
|
- |
Clause 11.2(Exact Length) |
- |
100 |
|
- |
Clause 11.1(Random Length) |
- |
100 |
|
- |
Clause 8.1 (Table3,4,5)(Nominal Bore ) |
- |
100 |
|
- |
Cl 15(Workmanship) |
- |
100 |
|
- |
Cl 14(Tensile Test, Flattening Test & Bend Test) |
- |
1500 |
|
- |
Cl 12(Workmanship) |
- |
100 |
|
- |
Cl 10.1.1(Manufacturing ) |
- |
100 |
|
- |
Cl 10.1(Manufacturing ) |
- |
100 |
|
- |
Cl 8(Outer Diameter, Thickness & Mass) |
- |
500 |
|
- |
17(Marking) |
- |
100 |
|
- |
cl.17(MARKING) |
- |
100 |
|
- |
6.2(Carbon Equivalent as CE- IS:8811-98(RA12)) |
- |
500 |
|
- |
|
07 Sep, 2025 |
- - |
48 |
IS 2202 : Part 2 (2022) |
WOODEN FLUSH DOOR SHUTTERS SOLID CORE TYPE SPECIFICATION PART 2 PARTICLE BOARD HIGH DENSITY FIBRE BOARD MEDIUM DENSITY FIBRE BOARD AND HARDBOARD FACE PANELS Fourth Revision |
ALL AS PER IS |
30000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Clause No - 6.1(Timber) |
- |
5000 |
|
- |
Clause No -6.2(Alternative Materials (LVL) |
- |
2500 |
|
- |
Clause No -6.2(Alternative Materials veneer laminated lumber (VLL)) |
- |
2500 |
|
- |
Clause No -6.2(Alternative Materials medium density fibre board (MDF)) |
- |
2500 |
|
- |
Clause No -6.2(Alternative Materials -plywood) |
- |
2500 |
|
- |
Clause No -6.2(BWP grade flush door shutter) |
- |
5000 |
|
- |
Clause No -6.3.1("Face Panels:
Particle Board
MDF/ HDF
Fibre Hardboard") |
- |
2500 |
|
- |
Clause No -6.4(Adhesive) |
- |
9000 |
|
- |
Clause No -7.1(Construction) |
- |
500 |
|
- |
Clause No - 7.3(" MDF board or
HDF board ") |
- |
5000 |
|
- |
Clause No -9.2("Workmanship and
finish") |
- |
500 |
|
- |
Clause No -10.1(tests for flush door shutters) |
- |
20000 |
|
- |
Clause No -10.2(End Immersion Test) |
- |
1500 |
|
- |
Clause No -10.3(Glue Adhesion Test) |
- |
1000 |
|
- |
Clause No -11(SAMPLING AND CRITERIA FOR CONFORMITY) |
- |
100 |
|
- |
Clause No -12("ADDITIONAL REQUIREMENTS FOR ECO
MARK") |
- |
100 |
|
- |
Clause No - 6.1(Timber) |
- |
2500 |
|
- |
Clause No -6.2(Alternative Materials (LVL) |
- |
2500 |
|
- |
Clause No -6.2(Alternative Materials medium density fibre board (MDF)) |
- |
500 |
|
- |
Clause No -6.2(Alternative Materials -plywood) |
- |
500 |
|
- |
Clause No -6.2(BWP grade flush door shutter) |
- |
500 |
|
- |
Clause No -6.3.1("Face Panels:
Particle Board
MDF/ HDF
Fibre Hardboard") |
- |
500 |
|
- |
Clause No -6.4(Adhesive) |
- |
9000 |
|
- |
Clause No -7.1(Construction) |
- |
500 |
|
- |
Clause No - 7.3(" MDF board or
HDF board ") |
- |
500 |
|
- |
Clause No -9.2("Workmanship and
finish") |
- |
200 |
|
- |
Clause No -10.1(tests for flush door shutters) |
- |
20000 |
|
- |
Clause No -10.2(End Immersion Test) |
- |
1500 |
|
- |
Clause No -10.3(Glue Adhesion Test) |
- |
500 |
|
- |
Clause No -11(SAMPLING AND CRITERIA FOR CONFORMITY) |
- |
1500 |
|
- |
Clause No -12("ADDITIONAL REQUIREMENTS FOR ECO
MARK") |
- |
1000 |
|
- |
Clause No -6.2(Alternative Materials veneer laminated lumber (VLL)) |
- |
1000 |
|
- |
5(SIZES AND TOLERANCES) |
- |
500 |
|
- |
6.5(The swelling in thickness of the particle board, MDF
and HDF board for core) |
- |
100 |
|
- |
|
07 Sep, 2025 |
- Included w.e.f. 04.03.2024
Garde- MR/BWP,
Type-BDPV/BNP/BNPV/PDPV/PNP/PNPV/MDPV/MNP/MNPV
Range- Length - up to 2450mm
Width-up to 1225mm
Thickness- up to 60mm
Designation- 8DS20 to 12DET21 |
49 |
IS 2202 : Part 1 (2023) |
WOODEN FLUSH DOOR SHUTTERS SOLID CORE TYPE SPECIFICATION PART 1 PLYWOOD FACE PANELS Seventh Revision |
Grade- MR/ BWP, TYPE- BD/ BN/PD/PN/MD/MN, SIZE - ALL |
30000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
11.1(Dimensions - Height) |
- |
200 |
|
- |
11.1(Dimensions - Thickness) |
- |
200 |
|
- |
11.1(Dimensions - Variation in thickness) |
- |
100 |
|
- |
11.1(Dimensions - Squareness) |
- |
100 |
|
- |
Clause 11.12(End Immersion Test) |
- |
2000 |
|
- |
Clause 11.13(Knife Test) |
- |
500 |
|
- |
Clause 11.14(Glue Adhesion Test) |
- |
500 |
|
- |
Clause 4.2(grades specified) |
- |
100 |
|
- |
Clause 5(SIZES) |
- |
100 |
|
- |
Clause 11.2(General Flatness Test) |
- |
200 |
|
- |
Clause 11.3(Local Planeness Test) |
- |
200 |
|
- |
Clause 11.4(Impact Indentation Test) |
- |
500 |
|
- |
Clause 11.5(Flexure Test) |
- |
1000 |
|
- |
Clause 11.6(Edge Loading Test) |
- |
1500 |
|
- |
Clause 11.7(Shock Resistance Test) |
- |
1000 |
|
- |
Clause 11.8(Buckling Resistance Test) |
- |
1000 |
|
- |
Clause 11.9(Slamming Test) |
- |
1000 |
|
- |
Clause 11.10(Misuse Test) |
- |
500 |
|
- |
Clause 11.11(Varying Humidity Test) |
- |
11000 |
|
- |
Clause 11.15(Screw Withdrawal
Resistance Test) |
- |
1500 |
|
- |
Clause 14(Marking) |
- |
100 |
|
- |
Clause 6.1.1(species of timber) |
- |
100 |
|
- |
Clause 6.1.2(list of species) |
- |
100 |
|
- |
Clause 6.1.3(moisture content) |
- |
100 |
|
- |
Clause 6.2.1(Plywood) |
- |
100 |
|
- |
Clause 6.2.2(Decorative plywood) |
- |
100 |
|
- |
Clause 6.3(Cross-Bands) |
- |
100 |
|
- |
Clause 6.6.1(Adhesives) |
- |
100 |
|
- |
Clause 6.7(Particle Board) |
- |
100 |
|
- |
Clause 6.9(Alternative Materials) |
- |
100 |
|
- |
Clause 7.1(Blockboard Core) |
- |
100 |
|
- |
Clause 7.2(Particle Board or
Medium Density Fibre) |
- |
100 |
|
- |
Clause 7.3(Stiles and Rails) |
- |
100 |
|
- |
Clause 7.4(Levelling) |
- |
100 |
|
- |
Clause 7.5(Face Panel) |
- |
100 |
|
- |
Clause 7.6(Lipping) |
- |
100 |
|
- |
Clause 7.7(Rebating) |
- |
100 |
|
- |
Clause 7.8(Opening for Glazing) |
- |
100 |
|
- |
Clause 7.9(Venetian) |
- |
100 |
|
- |
Clause 8.1(Locks) |
- |
100 |
|
- |
Clause 10.1(Classification of Tests) |
- |
100 |
|
- |
9.1(Workmanship & Finish) |
- |
100 |
|
- |
9.2(Workmanship & Finish) |
- |
100 |
|
- |
9.3(Workmanship & Finish) |
- |
100 |
|
- |
4(GRADE) |
- |
100 |
|
- |
4(TYPE) |
- |
100 |
|
- |
5(SIZES) |
- |
100 |
|
- |
7.1.1(CONSTRUCTION-Blockboard Core) |
- |
100 |
|
- |
7.1.1(CONSTRUCTION-Blockboard Core) |
- |
100 |
|
- |
7.1.2(CONSTRUCTION-Blockboard Core) |
- |
100 |
|
- |
7.3.2(CONSTRUCTION-Stiles and Rails) |
- |
100 |
|
- |
7.3.2(a)(CONSTRUCTION-Stiles and Rails-Joints) |
- |
100 |
|
- |
7.3.2(b)(CONSTRUCTION-Stiles and Rails-Joints) |
- |
100 |
|
- |
7.3.2(c)(CONSTRUCTION-Stiles and Rails-Joints) |
- |
100 |
|
- |
7.3.3(CONSTRUCTION-Stiles and Rails) |
- |
100 |
|
- |
9.1(WORKMANSHIP AND FINISH) |
- |
100 |
|
- |
9.2(WORKMANSHIP AND FINISH) |
- |
100 |
|
- |
9.3(WORKMANSHIP AND FINISH) |
- |
100 |
|
- |
11.1(Dimensions and Squareness Test) |
- |
100 |
|
- |
11.1(Dimensions and Squareness Test) |
- |
100 |
|
- |
11.1(Dimensions and Squareness Test) |
- |
100 |
|
- |
11.1(Dimensions and Squareness Test) |
- |
100 |
|
- |
11.1(Dimensions and Squareness Test) |
- |
100 |
|
- |
11.2(General Flatness Test) |
- |
100 |
|
- |
11.2(General Flatness Test) |
- |
100 |
|
- |
11.2(General Flatness Test) |
- |
100 |
|
- |
11.3(Local Planeness Test) |
- |
100 |
|
- |
11.4(Impact Indentation Test) |
- |
100 |
|
- |
11.4(Impact Indentation Test) |
- |
100 |
|
- |
11.5(Flexure Test) |
- |
1500 |
|
- |
11.5(Flexure Test) |
- |
1500 |
|
- |
11.6(Edge Loading Test) |
- |
1500 |
|
- |
11.6(Edge Loading Test) |
- |
1500 |
|
- |
11.6(Edge Loading Test) |
- |
1500 |
|
- |
11.6(Edge Loading Test) |
- |
1500 |
|
- |
11.7.1(Shock Resistance Test) |
- |
1000 |
|
- |
11.7.2(Shock Resistance Test) |
- |
1000 |
|
- |
11.8(Buckling Test) |
- |
1000 |
|
- |
11.8(Buckling Test) |
- |
1000 |
|
- |
11.8(Buckling Test) |
- |
1000 |
|
- |
11.9.2(Slamming Test) |
- |
1000 |
|
- |
11.9.3(Slamming Test) |
- |
1000 |
|
- |
11.10(Misuse Test) |
- |
500 |
|
- |
11.11(Varying Humidity Test) |
- |
6500 |
|
- |
11.11(Varying Humidity Test) |
- |
6500 |
|
- |
11.12(End Immersion Test) |
- |
500 |
|
- |
11.13(Knife Test) |
- |
100 |
|
- |
11.14(Glue Adhesion Test) |
- |
100 |
|
- |
11.15(Screw Withdrawal Resistance Test) |
- |
100 |
|
- |
11.15(Screw Withdrawal Resistance Test) |
- |
100 |
|
- |
4(Grade, Type and Construction) |
- |
100 |
|
- |
5(Sizes and Thickness) |
- |
100 |
|
- |
6.1(Timber) |
- |
100 |
|
- |
6.2(Plywood for flush door shutter) |
- |
100 |
|
- |
6.3(Cross-Bands ) |
- |
100 |
|
- |
6.4.1(Commercial Face Veneers) |
- |
100 |
|
- |
6.4.2(Decorative face veneers) |
- |
100 |
|
- |
6.6(Adhesives) |
- |
100 |
|
- |
6.7(Particle Board) |
- |
100 |
|
- |
6.8(Medium Density Fibre) |
- |
100 |
|
- |
6.9(Alternative Materials) |
- |
100 |
|
- |
7(Construction) |
- |
100 |
|
- |
8.1(Locks) |
- |
100 |
|
- |
8.2(Other Fittings) |
- |
100 |
|
- |
9(Workmanship and Finish) |
- |
100 |
|
- |
10(Tests) |
- |
100 |
|
- |
11.1(Dimensions and Squareness Test) |
- |
100 |
|
- |
11.2(General Flatness Test) |
- |
100 |
|
- |
11.3(Local Planeness Test) |
- |
100 |
|
- |
11.4(Impact Indentation Test) |
- |
100 |
|
- |
11.5(Flexure Test) |
- |
100 |
|
- |
11.6(Edge Loading Test) |
- |
100 |
|
- |
11.7(Shock Resistance Test) |
- |
100 |
|
- |
11.8(Buckling Resistance Test) |
- |
100 |
|
- |
11.9(Slamming Test) |
- |
100 |
|
- |
11.1(Misuse Test) |
- |
100 |
|
- |
11.11(Varying Humidity Test) |
- |
100 |
|
- |
11.12(End Immersion Test) |
- |
100 |
|
- |
11.13(Knife Test) |
- |
100 |
|
- |
11.14(Glue Adhesion Test) |
- |
100 |
|
- |
11.15(Screw Withdrawal Resistance Test) |
- |
100 |
|
- |
Clause 9(WORKMANSHIP AND
FINISH) |
- |
100 |
|
- |
Clause 13(ADDITIONAL REQUIREMENTS
FOR ECO MARK) |
- |
100 |
|
- |
11.1(Dimensions - Width) |
- |
100 |
|
- |
Clause 12(SAMPLING AND CRITERIA
FOR CONFORMITY) |
- |
100 |
|
- |
Clause 6.4.1(Commercial Face
Veneers) |
- |
100 |
|
- |
Clause 6.4.2(Decorative Face
Veneers) |
- |
100 |
|
- |
Clause 6.8(Medium density
fibre board) |
- |
100 |
|
- |
Clause 11.1(Dimensions and
Squareness Test) |
- |
100 |
|
- |
11.12(End immersion test) |
- |
100 |
|
- |
11.13(Knife Test) |
- |
100 |
|
- |
11.14(Glue Adhesion Test) |
- |
100 |
|
- |
14(Marking ) |
- |
100 |
|
- |
11.1(Dimensions - Height) |
- |
200 |
|
- |
11.1(Dimensions - Thickness) |
- |
200 |
|
- |
11.1(Dimensions - Variation in thickness) |
- |
100 |
|
- |
11.1(Dimensions - Squareness) |
- |
100 |
|
- |
Clause 11.12(End Immersion Test) |
- |
100 |
|
- |
Clause 11.13(Knife Test) |
- |
100 |
|
- |
Clause 11.14(Glue Adhesion Test) |
- |
100 |
|
- |
Clause 4.2(grades specified) |
- |
100 |
|
- |
Clause 5(SIZES) |
- |
100 |
|
- |
Clause 11.2(General Flatness Test) |
- |
100 |
|
- |
Clause 11.3(Local Planeness Test) |
- |
100 |
|
- |
Clause 11.4(Impact Indentation Test) |
- |
100 |
|
- |
Clause 11.5(Flexure Test) |
- |
100 |
|
- |
Clause 11.6(Edge Loading Test) |
- |
100 |
|
- |
Clause 11.7(Shock Resistance Test) |
- |
100 |
|
- |
Clause 11.8(Buckling Resistance Test) |
- |
100 |
|
- |
Clause 11.9(Slamming Test) |
- |
100 |
|
- |
Clause 11.10(Misuse Test) |
- |
100 |
|
- |
Clause 11.11(Varying Humidity Test) |
- |
100 |
|
- |
Clause 11.15(Screw Withdrawal
Resistance Test) |
- |
100 |
|
- |
Clause 14(Marking) |
- |
100 |
|
- |
Clause 6.1.1(species of timber) |
- |
100 |
|
- |
Clause 6.1.2(list of species) |
- |
100 |
|
- |
Clause 6.1.3(moisture content) |
- |
500 |
|
- |
Clause 6.2.1(Plywood) |
- |
500 |
|
- |
Clause 6.2.2(Decorative plywood) |
- |
500 |
|
- |
Clause 6.3(Cross-Bands) |
- |
100 |
|
- |
Clause 6.6.1(Adhesives) |
- |
500 |
|
- |
Clause 6.7(Particle Board) |
- |
100 |
|
- |
Clause 6.9(Alternative Materials) |
- |
100 |
|
- |
Clause 7.1(Blockboard Core) |
- |
100 |
|
- |
Clause 7.2(Particle Board or
Medium Density Fibre) |
- |
100 |
|
- |
Clause 7.3(Stiles and Rails) |
- |
100 |
|
- |
Clause 7.4(Levelling) |
- |
100 |
|
- |
Clause 7.5(Face Panel) |
- |
100 |
|
- |
Clause 7.6(Lipping) |
- |
100 |
|
- |
Clause 7.7(Rebating) |
- |
100 |
|
- |
Clause 7.8(Opening for Glazing) |
- |
100 |
|
- |
Clause 7.9(Venetian) |
- |
100 |
|
- |
Clause 8.1(Locks) |
- |
100 |
|
- |
Clause 10.1(Classification of Tests) |
- |
100 |
|
- |
9.1(Workmanship & Finish) |
- |
100 |
|
- |
9.2(Workmanship & Finish) |
- |
100 |
|
- |
9.3(Workmanship & Finish) |
- |
100 |
|
- |
4(GRADE) |
- |
100 |
|
- |
4(TYPE) |
- |
100 |
|
- |
5(SIZES) |
- |
100 |
|
- |
7.1.1(CONSTRUCTION-Blockboard Core) |
- |
100 |
|
- |
7.1.1(CONSTRUCTION-Blockboard Core) |
- |
100 |
|
- |
7.1.2(CONSTRUCTION-Blockboard Core) |
- |
100 |
|
- |
7.3.2(CONSTRUCTION-Stiles and Rails) |
- |
100 |
|
- |
7.3.2(a)(CONSTRUCTION-Stiles and Rails-Joints) |
- |
100 |
|
- |
7.3.2(b)(CONSTRUCTION-Stiles and Rails-Joints) |
- |
100 |
|
- |
7.3.2(c)(CONSTRUCTION-Stiles and Rails-Joints) |
- |
100 |
|
- |
7.3.3(CONSTRUCTION-Stiles and Rails) |
- |
100 |
|
- |
9.1(WORKMANSHIP AND FINISH) |
- |
100 |
|
- |
9.2(WORKMANSHIP AND FINISH) |
- |
100 |
|
- |
9.3(WORKMANSHIP AND FINISH) |
- |
100 |
|
- |
11.1(Dimensions and Squareness Test) |
- |
100 |
|
- |
11.1(Dimensions and Squareness Test) |
- |
100 |
|
- |
11.1(Dimensions and Squareness Test) |
- |
100 |
|
- |
11.1(Dimensions and Squareness Test) |
- |
100 |
|
- |
11.1(Dimensions and Squareness Test) |
- |
100 |
|
- |
11.2(General Flatness Test) |
- |
100 |
|
- |
11.2(General Flatness Test) |
- |
100 |
|
- |
11.2(General Flatness Test) |
- |
100 |
|
- |
11.3(Local Planeness Test) |
- |
100 |
|
- |
11.4(Impact Indentation Test) |
- |
100 |
|
- |
11.4(Impact Indentation Test) |
- |
100 |
|
- |
11.5(Flexure Test) |
- |
100 |
|
- |
11.5(Flexure Test) |
- |
100 |
|
- |
11.6(Edge Loading Test) |
- |
100 |
|
- |
11.6(Edge Loading Test) |
- |
100 |
|
- |
11.6(Edge Loading Test) |
- |
100 |
|
- |
11.6(Edge Loading Test) |
- |
100 |
|
- |
11.7.1(Shock Resistance Test) |
- |
100 |
|
- |
11.7.2(Shock Resistance Test) |
- |
100 |
|
- |
11.8(Buckling Test) |
- |
100 |
|
- |
11.8(Buckling Test) |
- |
100 |
|
- |
11.8(Buckling Test) |
- |
100 |
|
- |
11.9.2(Slamming Test) |
- |
100 |
|
- |
11.9.3(Slamming Test) |
- |
100 |
|
- |
11.10(Misuse Test) |
- |
100 |
|
- |
11.11(Varying Humidity Test) |
- |
100 |
|
- |
11.11(Varying Humidity Test) |
- |
100 |
|
- |
11.12(End Immersion Test) |
- |
100 |
|
- |
11.13(Knife Test) |
- |
100 |
|
- |
11.14(Glue Adhesion Test) |
- |
100 |
|
- |
11.15(Screw Withdrawal Resistance Test) |
- |
100 |
|
- |
11.15(Screw Withdrawal Resistance Test) |
- |
100 |
|
- |
4(Grade, Type and Construction) |
- |
100 |
|
- |
5(Sizes and Thickness) |
- |
100 |
|
- |
6.1(Timber) |
- |
100 |
|
- |
6.2(Plywood for flush door shutter) |
- |
100 |
|
- |
6.3(Cross-Bands ) |
- |
100 |
|
- |
6.4.1(Commercial Face Veneers) |
- |
100 |
|
- |
6.4.2(Decorative face veneers) |
- |
100 |
|
- |
6.6(Adhesives) |
- |
100 |
|
- |
6.7(Particle Board) |
- |
100 |
|
- |
6.8(Medium Density Fibre) |
- |
100 |
|
- |
6.9(Alternative Materials) |
- |
100 |
|
- |
7(Construction) |
- |
100 |
|
- |
8.1(Locks) |
- |
100 |
|
- |
8.2(Other Fittings) |
- |
100 |
|
- |
9(Workmanship and Finish) |
- |
100 |
|
- |
10(Tests) |
- |
100 |
|
- |
11.1(Dimensions and Squareness Test) |
- |
100 |
|
- |
11.2(General Flatness Test) |
- |
100 |
|
- |
11.3(Local Planeness Test) |
- |
100 |
|
- |
11.4(Impact Indentation Test) |
- |
100 |
|
- |
11.5(Flexure Test) |
- |
100 |
|
- |
11.6(Edge Loading Test) |
- |
100 |
|
- |
11.7(Shock Resistance Test) |
- |
100 |
|
- |
11.8(Buckling Resistance Test) |
- |
100 |
|
- |
11.9(Slamming Test) |
- |
100 |
|
- |
11.1(Misuse Test) |
- |
100 |
|
- |
11.11(Varying Humidity Test) |
- |
100 |
|
- |
11.12(End Immersion Test) |
- |
100 |
|
- |
11.13(Knife Test) |
- |
100 |
|
- |
11.14(Glue Adhesion Test) |
- |
100 |
|
- |
11.15(Screw Withdrawal Resistance Test) |
- |
100 |
|
- |
Clause 9(WORKMANSHIP AND
FINISH) |
- |
100 |
|
- |
Clause 13(ADDITIONAL REQUIREMENTS
FOR ECO MARK) |
- |
100 |
|
- |
11.1(Dimensions - Width) |
- |
100 |
|
- |
Clause 12(SAMPLING AND CRITERIA
FOR CONFORMITY) |
- |
100 |
|
- |
Clause 6.4.1(Commercial Face
Veneers) |
- |
100 |
|
- |
Clause 6.4.2(Decorative Face
Veneers) |
- |
100 |
|
- |
Clause 6.8(Medium density
fibre board) |
- |
100 |
|
- |
Clause 11.1(Dimensions and
Squareness Test) |
- |
100 |
|
- |
11.12(End immersion test) |
- |
100 |
|
- |
11.13(Knife Test) |
- |
100 |
|
- |
11.14(Glue Adhesion Test) |
- |
100 |
|
- |
14(Marking ) |
- |
100 |
|
- |
11.1(Dimensions - Height) |
- |
100 |
|
- |
11.1(Dimensions - Thickness) |
- |
100 |
|
- |
11.1(Dimensions - Variation in thickness) |
- |
100 |
|
- |
11.1(Dimensions - Squareness) |
- |
100 |
|
- |
Clause 11.12(End Immersion Test) |
- |
100 |
|
- |
Clause 11.13(Knife Test) |
- |
100 |
|
- |
Clause 11.14(Glue Adhesion Test) |
- |
100 |
|
- |
Clause 4.2(grades specified) |
- |
100 |
|
- |
Clause 5(SIZES) |
- |
100 |
|
- |
Clause 11.2(General Flatness Test) |
- |
100 |
|
- |
Clause 11.3(Local Planeness Test) |
- |
100 |
|
- |
Clause 11.4(Impact Indentation Test) |
- |
100 |
|
- |
Clause 11.5(Flexure Test) |
- |
100 |
|
- |
Clause 11.6(Edge Loading Test) |
- |
100 |
|
- |
Clause 11.7(Shock Resistance Test) |
- |
100 |
|
- |
Clause 11.8(Buckling Resistance Test) |
- |
100 |
|
- |
Clause 11.9(Slamming Test) |
- |
100 |
|
- |
Clause 11.10(Misuse Test) |
- |
100 |
|
- |
Clause 11.11(Varying Humidity Test) |
- |
1500 |
|
- |
Clause 11.15(Screw Withdrawal
Resistance Test) |
- |
1000 |
|
- |
Clause 14(Marking) |
- |
100 |
|
- |
Clause 6.1.1(species of timber) |
- |
100 |
|
- |
Clause 6.1.2(list of species) |
- |
100 |
|
- |
Clause 6.1.3(moisture content) |
- |
100 |
|
- |
Clause 6.2.1(Plywood) |
- |
100 |
|
- |
Clause 6.2.2(Decorative plywood) |
- |
100 |
|
- |
Clause 6.3(Cross-Bands) |
- |
100 |
|
- |
Clause 6.6.1(Adhesives) |
- |
100 |
|
- |
Clause 6.7(Particle Board) |
- |
100 |
|
- |
Clause 6.9(Alternative Materials) |
- |
100 |
|
- |
Clause 7.1(Blockboard Core) |
- |
100 |
|
- |
Clause 7.2(Particle Board or
Medium Density Fibre) |
- |
100 |
|
- |
Clause 7.3(Stiles and Rails) |
- |
100 |
|
- |
Clause 7.4(Levelling) |
- |
100 |
|
- |
Clause 7.5(Face Panel) |
- |
100 |
|
- |
Clause 7.6(Lipping) |
- |
100 |
|
- |
Clause 7.7(Rebating) |
- |
100 |
|
- |
Clause 7.8(Opening for Glazing) |
- |
100 |
|
- |
Clause 7.9(Venetian) |
- |
100 |
|
- |
Clause 8.1(Locks) |
- |
100 |
|
- |
Clause 10.1(Classification of Tests) |
- |
100 |
|
- |
9.1(Workmanship & Finish) |
- |
100 |
|
- |
9.2(Workmanship & Finish) |
- |
100 |
|
- |
9.3(Workmanship & Finish) |
- |
100 |
|
- |
4(GRADE) |
- |
100 |
|
- |
4(TYPE) |
- |
100 |
|
- |
5(SIZES) |
- |
100 |
|
- |
7.1.1(CONSTRUCTION-Blockboard Core) |
- |
100 |
|
- |
7.1.1(CONSTRUCTION-Blockboard Core) |
- |
100 |
|
- |
7.1.2(CONSTRUCTION-Blockboard Core) |
- |
100 |
|
- |
7.3.2(CONSTRUCTION-Stiles and Rails) |
- |
100 |
|
- |
7.3.2(a)(CONSTRUCTION-Stiles and Rails-Joints) |
- |
100 |
|
- |
7.3.2(b)(CONSTRUCTION-Stiles and Rails-Joints) |
- |
100 |
|
- |
7.3.2(c)(CONSTRUCTION-Stiles and Rails-Joints) |
- |
100 |
|
- |
7.3.3(CONSTRUCTION-Stiles and Rails) |
- |
100 |
|
- |
9.1(WORKMANSHIP AND FINISH) |
- |
100 |
|
- |
9.2(WORKMANSHIP AND FINISH) |
- |
100 |
|
- |
9.3(WORKMANSHIP AND FINISH) |
- |
100 |
|
- |
11.1(Dimensions and Squareness Test) |
- |
200 |
|
- |
11.1(Dimensions and Squareness Test) |
- |
200 |
|
- |
11.1(Dimensions and Squareness Test) |
- |
100 |
|
- |
11.1(Dimensions and Squareness Test) |
- |
100 |
|
- |
11.1(Dimensions and Squareness Test) |
- |
100 |
|
- |
11.2(General Flatness Test) |
- |
100 |
|
- |
11.2(General Flatness Test) |
- |
100 |
|
- |
11.2(General Flatness Test) |
- |
100 |
|
- |
11.3(Local Planeness Test) |
- |
500 |
|
- |
11.4(Impact Indentation Test) |
- |
500 |
|
- |
11.4(Impact Indentation Test) |
- |
100 |
|
- |
11.5(Flexure Test) |
- |
100 |
|
- |
11.5(Flexure Test) |
- |
100 |
|
- |
11.6(Edge Loading Test) |
- |
100 |
|
- |
11.6(Edge Loading Test) |
- |
100 |
|
- |
11.6(Edge Loading Test) |
- |
100 |
|
- |
11.6(Edge Loading Test) |
- |
100 |
|
- |
11.7.1(Shock Resistance Test) |
- |
100 |
|
- |
11.7.2(Shock Resistance Test) |
- |
100 |
|
- |
11.8(Buckling Test) |
- |
100 |
|
- |
11.8(Buckling Test) |
- |
100 |
|
- |
11.8(Buckling Test) |
- |
100 |
|
- |
11.9.2(Slamming Test) |
- |
100 |
|
- |
11.9.3(Slamming Test) |
- |
100 |
|
- |
11.10(Misuse Test) |
- |
100 |
|
- |
11.11(Varying Humidity Test) |
- |
100 |
|
- |
11.11(Varying Humidity Test) |
- |
100 |
|
- |
11.12(End Immersion Test) |
- |
100 |
|
- |
11.13(Knife Test) |
- |
100 |
|
- |
11.14(Glue Adhesion Test) |
- |
100 |
|
- |
11.15(Screw Withdrawal Resistance Test) |
- |
100 |
|
- |
11.15(Screw Withdrawal Resistance Test) |
- |
100 |
|
- |
4(Grade, Type and Construction) |
- |
100 |
|
- |
5(Sizes and Thickness) |
- |
100 |
|
- |
6.1(Timber) |
- |
100 |
|
- |
6.2(Plywood for flush door shutter) |
- |
100 |
|
- |
6.3(Cross-Bands ) |
- |
100 |
|
- |
6.4.1(Commercial Face Veneers) |
- |
100 |
|
- |
6.4.2(Decorative face veneers) |
- |
100 |
|
- |
6.6(Adhesives) |
- |
100 |
|
- |
6.7(Particle Board) |
- |
100 |
|
- |
6.8(Medium Density Fibre) |
- |
100 |
|
- |
6.9(Alternative Materials) |
- |
100 |
|
- |
7(Construction) |
- |
100 |
|
- |
8.1(Locks) |
- |
100 |
|
- |
8.2(Other Fittings) |
- |
100 |
|
- |
9(Workmanship and Finish) |
- |
100 |
|
- |
10(Tests) |
- |
100 |
|
- |
11.1(Dimensions and Squareness Test) |
- |
100 |
|
- |
11.2(General Flatness Test) |
- |
100 |
|
- |
11.3(Local Planeness Test) |
- |
100 |
|
- |
11.4(Impact Indentation Test) |
- |
100 |
|
- |
11.5(Flexure Test) |
- |
100 |
|
- |
11.6(Edge Loading Test) |
- |
100 |
|
- |
11.7(Shock Resistance Test) |
- |
100 |
|
- |
11.8(Buckling Resistance Test) |
- |
100 |
|
- |
11.9(Slamming Test) |
- |
100 |
|
- |
11.1(Misuse Test) |
- |
100 |
|
- |
11.11(Varying Humidity Test) |
- |
100 |
|
- |
11.12(End Immersion Test) |
- |
100 |
|
- |
11.13(Knife Test) |
- |
100 |
|
- |
11.14(Glue Adhesion Test) |
- |
100 |
|
- |
11.15(Screw Withdrawal Resistance Test) |
- |
100 |
|
- |
Clause 9(WORKMANSHIP AND
FINISH) |
- |
100 |
|
- |
Clause 13(ADDITIONAL REQUIREMENTS
FOR ECO MARK) |
- |
100 |
|
- |
11.1(Dimensions - Width) |
- |
100 |
|
- |
Clause 12(SAMPLING AND CRITERIA
FOR CONFORMITY) |
- |
100 |
|
- |
Clause 6.4.1(Commercial Face
Veneers) |
- |
100 |
|
- |
Clause 6.4.2(Decorative Face
Veneers) |
- |
100 |
|
- |
Clause 6.8(Medium density
fibre board) |
- |
100 |
|
- |
Clause 11.1(Dimensions and
Squareness Test) |
- |
100 |
|
- |
11.12(End immersion test) |
- |
100 |
|
- |
11.13(Knife Test) |
- |
100 |
|
- |
11.14(Glue Adhesion Test) |
- |
100 |
|
- |
14(Marking ) |
- |
100 |
|
- |
|
07 Sep, 2025 |
- Included w.e.f. 04.03.2024
Garde-MR/BWP,
Type- BD/BN/PD/PN/MD/MN
Range- Length-up to 2450mm
Width- up to 1225mm
Thickness- upto 60mm
Designation- 8DS20 to 12DT21 |
50 |
IS 513 : Part 1 (2016) |
Cold reduced carbon steel sheet and strip: Part 1 cold forming and drawing purpose (Sixth Revision) |
ALL |
8500 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
8(Mechanical and Physical Properties) |
- |
100 |
|
.... |
Cl 8(UTM) |
- |
1000 |
|
.... |
Cl 9(Workmanship) |
- |
200 |
|
.... |
Cl 9.6(Workmanship) |
- |
200 |
|
.... |
Cl 10(Workmanship) |
- |
200 |
|
.... |
Cl 11(Length, Width & Thickness) |
- |
500 |
|
.... |
7.0(ALUMINIUM) |
- |
800 |
|
.... |
7.0(MICRO ALLOYS) |
- |
800 |
|
.... |
7.0(NITROGEN) |
- |
800 |
|
... |
7.0(SILICON) |
- |
800 |
|
... |
7.0(MANGANESE) |
- |
800 |
|
... |
7.0(PHOSPHORUS) |
- |
800 |
|
... |
7.0(SULPHUR) |
- |
800 |
|
... |
7.0(CARBON) |
- |
800 |
|
... |
|
07 Sep, 2025 |
- - |
51 |
IS 2039 : Part 1 to 3 (1991) |
Steel tubes for bicycle and cycle rickshaws - Specification (Second Revision) |
ERW C1 to ERW C3 |
9300 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Cl. 5.1 Table 1(Carbon) |
- |
800 |
|
Testing Charges for Complete IS 2039(pt-1) -9300/- /IS 2039(pt-2) -9300/-/IS 2039(pt-3) -9300/- |
Cl. 5.1 Table 1(Silicon) |
- |
800 |
|
..... |
Cl. 5.1 Table 1(Manganese) |
- |
800 |
|
..... |
Cl. 5.1 Table 1(Phosphorous) |
- |
800 |
|
.... |
Cl. 5.1 Table 1(Sulphur) |
- |
800 |
|
.... |
Cl. 6.1(Workmanship) |
- |
200 |
|
..... |
Cl. 6.2(Fin Height) |
- |
500 |
|
.... |
Cl. 6.3(Straightness) |
- |
500 |
|
.... |
Cl. 8.1(Tensile Strength) |
- |
800 |
|
.... |
Cl. 8.1(Yield Strength) |
- |
600 |
|
.... |
Cl. 8.1(Elongation) |
- |
600 |
|
.... |
Cl. 8.2(Drift Expansion Test- IS 2335) |
- |
500 |
|
.... |
Cl. 8.3(Flattening Test-IS 2338) |
- |
500 |
|
.... |
Cl. 9(Diameter) |
- |
100 |
|
..... |
Cl. 9(Thickness) |
- |
100 |
|
..... |
Cl. 3.2.1, Table 4(Yield Stress) |
- |
600 |
|
.... |
Cl. 3.2.1, Table 4(UTS) |
- |
800 |
|
.... |
Cl. 3.2.1, Table 4(Elongation) |
- |
600 |
|
..... |
Cl. 3.2.2, Table 2(Drift Expansion Test- IS 2335) |
- |
500 |
|
.... |
Cl. 3.2.3, Table 3(Flattening Test-IS 2338) |
- |
500 |
|
.... |
Cl. 4.2.1(Diameter) |
- |
100 |
|
..... |
Cl. 4.2.2(Thickness) |
- |
100 |
|
.... |
Cl. 4.2.3(Length) |
- |
100 |
|
..... |
Cl. 3.1(Carbon) |
- |
800 |
|
.... |
Cl. 3.1(Silicon) |
- |
800 |
|
.... |
Cl. 3.1(Manganese) |
- |
800 |
|
.... |
Cl. 3.1(Phosphorous) |
- |
800 |
|
.... |
Cl. 3.1(Sulphur) |
- |
800 |
|
... |
Cl. 4.2.1, Table 7(Yield Stress) |
- |
600 |
|
.... |
Cl. 4.2.1, Table 7(UTS) |
- |
800 |
|
.... |
Cl. 4.2.1, Table 7(Crushing) |
- |
300 |
|
.... |
Cl. 4.2.2, Table 8(Drift Expansion Test- IS 2335) |
- |
600 |
|
.... |
Cl. 4.2.3, Table 9(Flattening Test-IS 2338) |
- |
500 |
|
... |
Cl. 5.2.1, Table 10(Diameter) |
- |
100 |
|
.... |
Cl. 5.2.2(Mean Thickness) |
- |
100 |
|
.... |
Cl. 5.2.3, Table 6(Length) |
- |
100 |
|
... |
|
07 Sep, 2025 |
- - |
52 |
IS 5509 (2021) |
Fire Retardant Plywood - Specification ( Third Revision ) |
TYPE-1 TO TYPE-5 |
10700 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
4.1(Type based on Flame retardant chemical used) |
- |
200 |
|
... |
8(a) Length) |
- |
200 |
|
... |
8(b) Width) |
- |
200 |
|
... |
8(c) Thickness 1) less than 6mm ±10%
2) 6 mm and above ±5%
) |
- |
200 |
|
... |
8.3 & Annex A (d) Edge Straightness 0.2% Max.) |
- |
500 |
|
... |
8.3 & Annex A (e) Edge Squareness 0.2% Max.) |
- |
500 |
|
... |
9(Workmanship and finish) |
- |
200 |
|
... |
12(Test Requirements ) |
- |
500 |
|
... |
12.2(Moisture content ) |
- |
1000 |
|
.... |
12.3.1(Flammability ) |
- |
1000 |
|
.... |
12.3.2(Flame Penetration ) |
- |
1000 |
|
.... |
12.2.3(Rate of burning ) |
- |
1500 |
|
.... |
12.4(Glue adhesion (water resistance )) |
- |
1000 |
|
... |
12.4(Static Bending Strength as per BWR grade of IS 303 :) |
- |
1000 |
|
... |
12.4(Modulus of Rupture, (Along the grain direction of the face veneer)) |
- |
1000 |
|
.... |
12.4(Modulus of Rupture, (Along the grain direction of the face veneer)) |
- |
1000 |
|
.... |
8.3 (Table 1)(b) 6 mm and above) |
- |
10700 |
|
10700/- FULL REPORT AS PER IS 5509:2021 |
|
07 Sep, 2025 |
- - |
53 |
IS 3601 (2006) |
Steel tubes for mechanical and general engineering purposes - Specification (Second Revision) |
- |
8000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
4(Material) |
- |
100 |
|
.... |
13(Mechanical Testing) |
- |
2000 |
|
Tensile , Yield, Elongation. |
6.0(Workmanship) |
- |
100 |
|
... |
4.1(Sulphur-Percentage by mass) |
- |
700 |
|
Each Parameter - Rs-700/- |
4.1(Phosphorus-Percentage by mass) |
- |
700 |
|
Each Parameter - Rs-700/- |
8.0(Straightness) |
- |
100 |
|
.. |
19.1.1, 24.1.1, 28.1.1, 33.1.1(Dimensions- Outside Dia) |
- |
150 |
|
... |
19.1.2, 24.1.2, 28.1.2, 33.1.2(Dimensions- Thickness) |
- |
150 |
|
... |
11.1(Surface Protection) |
- |
100 |
|
... |
11.2(Surface Protection) |
- |
100 |
|
... |
13.1.3(Tensile Strength) |
- |
800 |
|
.... |
13.1.1(Yield Stress) |
- |
600 |
|
.... |
13.1.2(Elongation) |
- |
600 |
|
.... |
13.2(Flattening Test) |
- |
500 |
|
.... |
13.3(Bend Test (Strip)) |
- |
500 |
|
.... |
13.4(Bend Test (Whole Tube)) |
- |
500 |
|
.... |
13.5(Drift Expansion Test) |
- |
500 |
|
.... |
13.6(Crush Test) |
- |
500 |
|
.... |
19.1.3(Height of Internal Fin) |
- |
200 |
|
.... |
4.1(Sulphur-Percentage by mass) |
- |
100 |
|
- |
|
07 Sep, 2025 |
- - |
54 |
IS 5531 (2014) |
Cast iron specials for asbestos cement pressure pipes for water and sewage - Specification (Third Revision) |
- |
7300 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Cl. 5(WALL THICKNESS AND CLASSIFICATION) |
- |
200 |
|
... |
Cl. 6.2(Tensile Test) |
- |
2000 |
|
.... |
Cl. 6.3(Brinell Hardness Test) |
- |
500 |
|
.... |
Cl. 6.4(Retest) |
- |
300 |
|
... |
Cl. 7(HYDROSTATIC TEST) |
- |
2000 |
|
... |
Cl. 7.1.1 (Table 1)(Hydrostatic Test Pressure at Works) |
- |
500 |
|
... |
Cl. 8(SIZES) |
- |
200 |
|
... |
Cl. 9(DIMENSIONS) |
- |
500 |
|
.. |
Cl. 10.1(Thickness) |
- |
100 |
|
... |
Cl. 10.2(Tolerance) |
- |
200 |
|
... |
Cl. 12(COATING) |
- |
800 |
|
... |
Cl. 5(WALL THICKNESS AND CLASSIFICATION) |
- |
200 |
|
.... |
Cl. 6.2(Tensile Test) |
- |
2000 |
|
... |
Cl. 6.3(Brinell Hardness Test) |
- |
1000 |
|
.... |
Cl. 6.4(Retest) |
- |
200 |
|
.... |
Cl. 7(HYDROSTATIC TEST) |
- |
1500 |
|
... |
Cl. 7.1.1 (Table 1)(Hydrostatic Test Pressure at Works) |
- |
500 |
|
.... |
Cl. 8(SIZES) |
- |
200 |
|
.... |
Cl. 9(DIMENSIONS) |
- |
500 |
|
... |
Cl. 10.1(Thickness) |
- |
200 |
|
.... |
Cl. 12(COATING) |
- |
1000 |
|
.... |
|
07 Sep, 2025 |
- - |
55 |
IS 2191 : Part 1 (1983) |
Specification for wooden flush door shuiters (Cellular And Hollow Core Type): Part 1 plywood face panels (Fourth Revision) |
- |
15000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Cl. 4 (Table-2)(Size- Height) |
- |
500 |
|
... |
Cl. 4 (Table-2)(Size- Width) |
- |
500 |
|
... |
Cl. 4.2 (Nominal thickness of shutters) |
- |
500 |
|
.... |
Cl. 5.1(Timber) |
- |
500 |
|
... |
Cl. 5.2(Plywood) |
- |
500 |
|
.... |
Cl. 5.3(Cross-Bands) |
- |
500 |
|
.... |
Cl. 5.4(Face Veneers) |
- |
500 |
|
.... |
Cl. 5.6(Adhesive) |
- |
500 |
|
... |
Cl. 5.7(Particle Board) |
- |
499.99 |
|
.... |
Cl. 6(CONSTRUCTION) |
- |
500 |
|
.... |
Cl. 6.1(Cellular Core) |
- |
500 |
|
.... |
Cl. 6.2(Hollow Core) |
- |
500 |
|
.... |
Cl. 6.3(Stiles and Rails) |
- |
500 |
|
.... |
Cl. 6.4(Levelling) |
- |
500 |
|
... |
Cl. 6.5(Face Panel) |
- |
500 |
|
... |
Cl. 6.6(Lipping) |
- |
500 |
|
... |
Cl. 6.7(Rebating) |
- |
500 |
|
... |
Cl. 6.8(Opening for Glazing) |
- |
500 |
|
... |
Cl. 6.9(Venetian) |
- |
500 |
|
... |
Cl. 7(FITTINGS) |
- |
1000 |
|
.. |
Cl. 7.1(Locks) |
- |
500 |
|
... |
Cl. 8(WORKMANSHIP AND FINISH) |
- |
200 |
|
... |
Cl. 9.1(End immersion Test) |
- |
1500 |
|
... |
Cl. 9.2(Knife Test) |
- |
500 |
|
.... |
Cl. 9.3(Adhesion Test) |
- |
500 |
|
... |
|
07 Sep, 2025 |
- - |
56 |
IS 21 (1992) |
Wrought aluminium and aluminium alloys for manufacture of utensils specification (Fourth Revision) |
ALL GRADE |
6000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
4.2,
Table 2 of IS:21 (Designation & Condition 31000, 'H1')(Bend Test (Radius of Bend)) |
- |
500 |
|
- |
4.2,
Table 2 of IS:21 (Designation & Condition 31000, 'H1')(Elongation on 50 mm gauge length (For thickness over 2.6 to 6.3 mm)) |
- |
300 |
|
- |
4.2,
Table 2 of IS:21 (Designation & Condition 31000, 'H1')(Tensile Strength) |
- |
1000 |
|
- |
4.2,
Table 1of IS:21 (Designation 31000)(Aluminium) |
- |
600 |
|
- |
4.2,
Table 1of IS:21 (Designation 31000)(Lead) |
- |
600 |
|
- |
4.2,
Table 1of IS:21 (Designation 31000)(Chromium) |
- |
600 |
|
- |
4.2,
Table 1of IS:21 (Designation 31000)(Titanium and or other grain refining elements) |
- |
600 |
|
- |
4.2,
Table 1of IS:21 (Designation 31000)(Zinc) |
- |
600 |
|
- |
4.2,
Table 1of IS:21 (Designation 31000)(Manganese) |
- |
600 |
|
- |
4.2,
Table 1of IS:21 (Designation 31000)(Iron) |
- |
600 |
|
- |
4.2,
Table 1of IS:21 (Designation 31000)(Silicon) |
- |
600 |
|
- |
4.2,
Table 1of IS:21 (Designation 31000)(Magnesium) |
- |
600 |
|
- |
4.2,
Table 1of IS:21 (Designation 31000)(Copper) |
- |
600 |
|
- |
4.2,
Table 2 of IS:21 (Designation & Condition 19000, 'H1')(Bend Test (Radius of Bend)) |
- |
600 |
|
- |
4.2,
Table 2 of IS:21 (Designation & Condition 19000, 'H1')(Elongation on 50 mm gauge length (For thickness over 2.6 to 6.3 mm)) |
- |
600 |
|
- |
4.2,
Table 2 of IS:21 (Designation & Condition 19000, 'H1')(Tensile Strength) |
- |
600 |
|
- |
4.2,
Table 1of IS:21 (Designation 19000)(Lead) |
- |
600 |
|
- |
4.2,
Table 1of IS:21 (Designation 19000)(Cu+Mg+Si+Fe+Mn+Zn) |
- |
600 |
|
- |
4.2,
Table 1of IS:21 (Designation 19000)(Aluminium) |
- |
600 |
|
- |
4.2,
Table 1of IS:21 (Designation 19000)(Zinc) |
- |
600 |
|
- |
4.2,
Table 1of IS:21 (Designation 19000)(Manganese) |
- |
600 |
|
- |
4.2,
Table 1of IS:21 (Designation 19000)(Iron) |
- |
600 |
|
- |
4.2,
Table 1of IS:21 (Designation 19000)(Silicon) |
- |
600 |
|
- |
4.2,
Table 1of IS:21 (Designation 19000)(Magnesium) |
- |
600 |
|
- |
4.2,
Table 1of IS:21 (Designation 19000)(Copper) |
- |
600 |
|
- |
|
07 Sep, 2025 |
- - |
57 |
IS 1264 (1997) |
Brass gravity die castings - Specification (Fourth Revision) |
DCB-1,DCB-2 |
2100 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
5.0(Freedom from defects) |
- |
50 |
|
.... |
6.0(Shape) |
- |
50 |
|
.... |
6.0(Size) |
- |
50 |
|
... |
6.0(Mass) |
- |
0 |
|
... |
7.0(Cu) |
- |
500 |
|
.. |
7.0(Sn) |
- |
500 |
|
.. |
7.0(Pb) |
- |
500 |
|
... |
7.0(Ni) |
- |
500 |
|
.. |
7.0(Fe) |
- |
500 |
|
.. |
7.0(Al) |
- |
500 |
|
... |
7.0(Mn) |
- |
500 |
|
.. |
7.0(Si) |
- |
500 |
|
... |
7.0(Total impurities excluding Ni Pb Al Zn) |
- |
100 |
|
.... |
9.0(Pressure test) |
- |
0 |
|
... |
|
07 Sep, 2025 |
- - |
58 |
IS 15647 (2006) |
Hot rolled steel narrow width strip for welded tubes and pipes |
GRADE 1,2,3 |
8200 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Cl 8(UTM) |
- |
2500 |
|
Rs-800/ for chemical test (each parameter) |
Cl 9(Press) |
- |
800 |
|
... |
Cl 11(Workmanship) |
- |
500 |
|
.... |
Cl 12(Length, Width & Thickness) |
- |
500 |
|
... |
Cl 13(Workmanship) |
- |
300 |
|
... |
|
07 Sep, 2025 |
- - |
59 |
IS 15380 (2003) |
Moulded Raised High Density Fibre (HDF) Panel Doors - |
BWP |
31000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
5, Table-1(dimension ) |
- |
500 |
|
--.. |
11.11(varying humidity test) |
- |
7500 |
|
--.. |
11.14(screw withdrawal resistance test) |
- |
3000 |
|
--.. |
11.7(shock resistance test) |
- |
2000 |
|
..... |
7.1(Heavy duty (Construction)) |
- |
500 |
|
... |
7.2(Light duty) |
- |
500 |
|
... |
7.3(Empanelment) |
- |
500 |
|
... |
7.4(Lipping ) |
- |
500 |
|
... |
7.5(rebating ) |
- |
500 |
|
... |
9(workmanship and finish) |
- |
500 |
|
... |
11.1(Dimension and squareness test) |
- |
1000 |
|
... |
11.2(General flatness test) |
- |
1000 |
|
... |
11.3(low Planeness Teat) |
- |
1000 |
|
... |
11.4(Impact Indentation Test) |
- |
1000 |
|
... |
11.5(Flexure Test) |
- |
1500 |
|
... |
11.6(edge loading test) |
- |
2000 |
|
... |
11.8(Buckling Test) |
- |
2000 |
|
... |
11.9(slamming Test) |
- |
1000 |
|
.... |
11.1(misuse test) |
- |
1000 |
|
... |
11.12(end immersion test) |
- |
2500 |
|
.... |
11.13(glue adhesion test) |
- |
1000 |
|
.... |
|
07 Sep, 2025 |
- - |
60 |
IS 14587 (1998) |
Prelaminated Medium Density Fibre Board -specification |
GRADE-1,2 |
18700 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
8(Dimensions and tolerances) |
- |
500 |
|
... |
10.6(test for modulis of rupture) |
- |
2500 |
|
.... |
10.8(Test for tensile strength perpendicular to Surface after ageing ) |
- |
2500 |
|
... |
10.2, Table-1(Test for Density) |
- |
1000 |
|
.... |
10.4, Table-1(Test for Water Absorption) |
- |
1500 |
|
.... |
10.5(test for swelling in water) |
- |
1500 |
|
.... |
10.7(Test for tensile strength perpendicular to Surface) |
- |
2000 |
|
.... |
10.9(test screw withdrawal strength) |
- |
1500 |
|
.... |
10.1(test for surface abrasion resistance) |
- |
1500 |
|
... |
10.11(test for resistance to steam) |
- |
1500 |
|
.... |
10.12(test for resistance to crack) |
- |
1000 |
|
.... |
10.13(test for resistance to cigarette burn) |
- |
1000 |
|
.... |
10.14(test for resistance to stain) |
- |
1000 |
|
.... |
|
07 Sep, 2025 |
- - |