4(Level of protection (equipment protection level, EPL)) |
- |
0 |
|
No separate test Charges. |
4.1(General) |
- |
0 |
|
No separate test Charges. |
4.4(Requirements for level of protection “dc”) |
- |
0 |
|
No separate test Charges. |
4.4.1(General) |
- |
0 |
|
No separate test Charges. |
4.4.2(Construction of “dc” devices) |
- |
0 |
|
No separate test Charges. |
4.4.2.1(General) |
- |
0 |
|
No separate test Charges. |
4.4.2.2(Free internal volume) |
- |
0 |
|
No separate test Charges. |
4.4.2.3(Seal protection) |
- |
0 |
|
No separate test Charges. |
4.4.2.4(Continuous operating temperature (COT) requirements) |
- |
0 |
|
No separate test Charges. |
4.4.2.5(Ratings) |
- |
0 |
|
No separate test Charges. |
4.4.3(Tests for “dc” devices) |
- |
0 |
|
No separate test Charges. |
5(Flameproof joints) |
- |
12000 |
|
Test charge includes all clauses under Cl. 5 |
5.1(General requirements) |
- |
0 |
|
Test charge included in Cl. 5 |
5.2(Non-threaded joints) |
- |
0 |
|
Test charge included in Cl. 5 |
5.2.1(Width of joints (L)) |
- |
0 |
|
Test charge included in Cl. 5 |
5.2.2(Gap (i)) |
- |
0 |
|
Test charge included in Cl. 5 |
5.2.3(Spigot joints) |
- |
0 |
|
Test charge included in Cl. 5 |
5.2.4(Holes in joint surfaces) |
- |
0 |
|
Test charge included in Cl. 5 |
5.2.5(Conical joints) |
- |
0 |
|
Test charge included in Cl. 5 |
5.2.6(Joints with partial cylindrical surfaces (not permitted for Group IIC)) |
- |
0 |
|
Test charge included in Cl. 5 |
5.2.7(Flanged joints for acetylene atmospheres) |
- |
0 |
|
Test charge included in Cl. 5 |
5.2.8(Serrated joints) |
- |
0 |
|
Test charge included in Cl. 5 |
5.2.9(Multi-step joints) |
- |
0 |
|
Test charge included in Cl. 5 |
5.3(Threaded joints) |
- |
0 |
|
Test charge included in Cl. 5 |
5.4(Gaskets (including O-rings)) |
- |
0 |
|
Test charge included in Cl. 5 |
5.5(Equipment using capillaries) |
- |
0 |
|
Test charge included in Cl. 5 |
6(Sealed joints) |
- |
333600 |
|
Test charge includes all clauses under cl. 6 |
6.1(Cemented joints) |
- |
0 |
|
Test charge included in Cl. 6 |
6.1.1(General) |
- |
0 |
|
Test charge included in Cl. 6 |
6.1.2(Mechanical strength) |
- |
0 |
|
Test charge included in Cl. 6 |
6.1.3(Width of cemented joints) |
- |
0 |
|
Test charge included in Cl. 6 |
6.2(Fused glass joints) |
- |
0 |
|
Test charge included in Cl. 6 |
6.2.2(Width of fused glass joints) |
- |
0 |
|
Test charge included in Cl. 6 |
7(Operating rods) |
- |
0 |
|
No separate test Charges. |
8.1.1(Joints of shafts) |
- |
0 |
|
No separate test Charges. |
8.1.2(Cylindrical joints) |
- |
0 |
|
No separate test Charges. |
8.1.3(Labyrinth joints) |
- |
0 |
|
No separate test Charges. |
8.1.4(Joints with floating glands) |
- |
0 |
|
No separate test Charges. |
8.2.1(Sleeve bearings) |
- |
0 |
|
No separate test Charges. |
8.2.2(Rolling-element bearings) |
- |
0 |
|
No separate test Charges. |
9(Light-transmitting parts) |
- |
0 |
|
No separate test Charges. |
10.2(Openings for breathing or draining) |
- |
0 |
|
Facility not available |
10.3(Composition limits) |
- |
0 |
|
Facility not available |
10.4(Dimensions) |
- |
0 |
|
Facility not available |
10.5(Elements with measurable paths) |
- |
0 |
|
Facility not available |
10.6(Elements with non-measurable paths) |
- |
0 |
|
Facility not available |
10.7.1(Removable devices) |
- |
0 |
|
Facility not available |
10.7.2(Mounting arrangements of the elements) |
- |
0 |
|
Facility not available |
10.8(Mechanical strength) |
- |
0 |
|
Facility not available |
10.9(Breathing devices and draining devices when used as Ex components) |
- |
0 |
|
Facility not available |
10.9.1(General) |
- |
0 |
|
Facility not available |
10.9.2(Mounting arrangements of the elements and components) |
- |
0 |
|
Facility not available |
10.9.3(Thermal tests - Test procedure as per Cl 10.9.3.2.2) |
- |
0 |
|
Facility not available |
10.9.3.3(Test for non-transmission of an internal ignition - Test procedure as per Cl 10.9.3.3.2) |
- |
0 |
|
Facility not available |
10.9.3.4(Test of the ability of the breathing and draining device to withstand pressure -Test procedure as per Cl 10.9.3.4.1) |
- |
0 |
|
Facility not available |
10.9.4(Ex component certificate) |
- |
0 |
|
Facility not available |
11.1(Fasteners and openings) |
- |
0 |
|
No separate test Charges. |
11.2(Fasteners and openings) |
- |
0 |
|
No separate test Charges. |
11.3(Fasteners and openings) |
- |
0 |
|
No separate test Charges. |
11.4(Fasteners and openings) |
- |
0 |
|
No separate test Charges. |
11.5(Fasteners and openings) |
- |
0 |
|
No separate test Charges. |
11.6(Fasteners and openings) |
- |
0 |
|
No separate test Charges. |
11.7(Fasteners and openings) |
- |
0 |
|
No separate test Charges. |
11.8(Fasteners and openings) |
- |
0 |
|
No separate test Charges. |
11.9(Fasteners and openings) |
- |
0 |
|
No separate test Charges. |
12.1(Materials) |
- |
0 |
|
No separate test Charges. |
12.2(Materials) |
- |
0 |
|
No separate test Charges. |
12.3(Materials) |
- |
0 |
|
No separate test Charges. |
12.4(Materials) |
- |
0 |
|
No separate test Charges. |
12.5(Materials) |
- |
0 |
|
No separate test Charges. |
12.6(Materials) |
- |
0 |
|
No separate test Charges. |
12.7(Materials) |
- |
0 |
|
No separate test Charges. |
12.8(Materials) |
- |
0 |
|
No separate test Charges. |
13.1(Entries for flameproof enclosures) |
- |
0 |
|
No separate test Charges. |
13.2(Threaded holes) |
- |
0 |
|
No separate test Charges. |
13.3(Non-threaded holes (for Group I only)) |
- |
0 |
|
No separate test Charges. |
13.4(Cable glands) |
- |
0 |
|
No separate test Charges. |
13.5.1(Conduit sealing devices) |
- |
0 |
|
No separate test Charges. |
13.5.2(Conduit sealing devices) |
- |
0 |
|
No separate test Charges. |
13.5.3(Conduit sealing devices) |
- |
0 |
|
No separate test Charges. |
13.6.1(Plugs and sockets and cable couplers) |
- |
3000 |
|
Test charge includes all clauses under cl. no. 13.6 |
13.6.2(Plugs and sockets and cable couplers) |
- |
0 |
|
Test Charges included in Cl. 13.6.1 |
13.6.3(Plugs and sockets and cable couplers) |
- |
0 |
|
Test Charges included in Cl. 13.6.1 |
13.6.4(Plugs and sockets and cable couplers) |
- |
0 |
|
Test Charges included in Cl. 13.6.1 |
13.6.5(Plugs and sockets and cable couplers) |
- |
0 |
|
Test Charges included in Cl. 13.6.1 |
13.7(Bushings) |
- |
0 |
|
No separate test Charges. |
13.8(Blanking elements) |
- |
0 |
|
No separate test Charges. |
15.2.1(Tests of ability of the enclosure to withstand pressure) |
- |
0 |
|
No separate test Charges. |
15.2.2(Determination of explosion pressure (reference pressure)) |
- |
45000 |
|
Test charge includes all clauses under cl. 15.2.2 |
15.2.3.2(Overpressure test – First method (static)) |
- |
7500 |
|
Test Charges of Cl. 15.2.3.2 |
15.3.1(Test for non-transmission of an internal ignition) |
- |
0 |
|
No separate test Charges. |
15.3.2(Electrical equipment of Groups I, IIA and IIB) |
- |
30000 |
|
Test charge includes all clauses under cl. 15.3.2 |
15.3.3(Electrical equipment of Group lIC) |
- |
22500 |
|
Test charge includes all clauses under cl. 15.3.3 |
15.5(Tests for “dc” devices - Test procedure as per Cl 15.5.3.2) |
- |
45000 |
|
Test charge includes all clauses under cl. 15.5 |
17(Switchgear for Group I) |
- |
0 |
|
No separate test Charges. |
17.2.1(Means of isolation) |
- |
0 |
|
No separate test Charges. |
17.2.2(Means of isolation) |
- |
0 |
|
No separate test Charges. |
17.2.3(Means of isolation) |
- |
0 |
|
No separate test Charges. |
17.2.4(Means of isolation) |
- |
0 |
|
No separate test Charges. |
17.3(Doors or covers) |
- |
0 |
|
No separate test Charges. |
17.3.1(Quick-acting doors or covers) |
- |
0 |
|
No separate test Charges. |
17.3.2(Doors or covers fixed by screws) |
- |
0 |
|
No separate test Charges. |
17.3.3(Threaded doors or covers) |
- |
0 |
|
No separate test Charges. |
18(Lampholders and Iamp caps) |
- |
0 |
|
No separate test Charges. |
18.2(Device preventing lamps working loose) |
- |
0 |
|
No separate test Charges. |
18.3.1(Holders and caps for lamps with cylindrical caps) |
- |
0 |
|
No separate test Charges. |
18.3.2(Holders and caps for lamps with cylindrical caps) |
- |
0 |
|
No separate test Charges. |
18.4.1(Holders for lamps with threaded caps) |
- |
0 |
|
No separate test Charges. |
18.4.2(Holders for lamps with threaded caps) |
- |
0 |
|
No separate test Charges. |
18.4.3(Holders for lamps with threaded caps) |
- |
0 |
|
No separate test Charges. |
19.1(Non-metallic enclosures and non-metallic parts of enclosures) |
- |
0 |
|
No separate test Charges. |
19.2(Resistance to tracking and creepage distances on internal surfaces of the
enclosure walls) |
- |
0 |
|
No separate test Charges. |
19.4(Test of erosion by flame) |
- |
30000 |
|
Test Charges of Cl. 19.4 |
20(Marking) |
- |
0 |
|
No separate test Charges. |
20.1(General) |
- |
0 |
|
No separate test Charges. |
20.2(Caution and warning markings) |
- |
0 |
|
No separate test Charges. |
20.3(Informative markings) |
- |
0 |
|
No separate test Charges. |
21(Instructions) |
- |
0 |
|
No separate test Charges. |
4.3(Requirements for level of protection “db”) |
- |
0 |
|
No separate test Charges. |