1 |
IS 636 (2018) |
Non - Percolating flexible fire fighting delivery hose - Specification (Fourth Revision) |
-
|
31500 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Cl 6.1.1(Inner lining shall be of rubber or rubberized fabric lining which is generally smooth and practically free
from pitting and other imperfections) |
- |
500 |
|
For Type 1 -Rs. 26,500/-
For Type 2 - Rs. 29,000/-
For Type 3 - Rs. 31,500/- |
Cl 6.1.2(Externally applied elastomeric coating or
covering of the reinforcement, if present shall be
generally smooth and practically free from pitting and
other imperfections) |
- |
500 |
|
- |
Cl 6.1.3(The jacket shall be practically free from dirt, knots,
lumps, irregularities of the yarn and other visible defects.) |
- |
500 |
|
- |
Cl.6.2(The internal diameter of the hose shall be measured by
a suitable conical plug gauge and shall conform to the
specified diameter with a tolerance of plus 2 and minus
0.0 mm.) |
- |
500 |
|
- |
Cl.6.3(Unless specified otherwise, the standard length shall
be 30 m. Unless otherwise specified, a tolerance of ± 2
percent shall be permitted on the length prescribed for
the hose by the purchaser but the total of all lengths of
hose supplied shall be not less than the total quantity
specified by the purchaser.) |
- |
750 |
|
- |
Cl.6.4(The average mass of hose per meter of 2 m length,
without couplings attached, shall not be more than that
prescribed in Table 1. For the determination of mass,
sample of the hose shall be conditioned at 27 ± 2°C and
65 ± 5 percent relative humidity for a period of at least
48 h and then shall be weighed under the same conditions.) |
- |
1000 |
|
- |
Cl.6.5(For 30 m length of dry hose without couplings, the coil
diameter shall not exceed 45 cm for Type 1, 50 cm for
Type 2 and 55 cm for Type 3.) |
- |
750 |
|
- |
Cl.6.6(Each hose length shall be subjected to an internal hydraulic pressure of 23 kgf/cm² in accordance with 8.1 of IS 443
(Part 3) increasing the pressure at the rate not exceeding
10 kgf/cm² per min and maintaining it for 1 min. Within
this 1 min, the hose shall neither develop any leakage or
sweating, nor shall any thread in the jacket break.) |
- |
3000 |
|
- |
Cl.6.7(A test length of hose, 1 m clear of fittings when
subjected to an internal hydraulic pressure in
accordance with 8.3 of IS 443 (Part 3) while increasing
the pressure at the rate not exceeding 10 kgf/cm2 per
min shall not burst or show leakage before a pressure
of 38 kgf/cm2 is reached) |
- |
3000 |
|
- |
Cl.6.8(There shall be no sign of leakage or rupture and no thread in the jacket shall break after retaining the internal hydraulic pressure of 23 kgf/cm2 for 30 seconds.) |
- |
3000 |
|
- |
Cl.6.9(The increase in length shall not exceed 6 percent at an internal hydraulic pressure of 10 kgf/cm2 for 2 minutes.) |
- |
1500 |
|
- |
Cl.6.10(The increase in diameter shall not be more than 10% at an internal hydraulic pressure of 10 kgf/cm2 for 2 minutes.) |
- |
1500 |
|
- |
Cl 6.11 (Adhesion (Cl. 6.11.1))(Rate of separation shall not exceed 25 mm/min 1) Cover) |
- |
1000 |
|
- |
Cl.6.11 Acccleraled Ageing Test (Cl. 6.11.2) - 1)(After ageing, there shall be no tackiness on the surface of lining or the surface of the cover. ) |
- |
3000 |
|
- |
Cl.6.12(When determined by the method described in Annex C,
the average number of cycles completed before bursting
of three test pieces, shall not be less than the value
specified in Table 2.) |
- |
2500 |
|
- |
Cl.6.13(When tested in accordance with Annex D, the amount
of moisture absorbed shall not exceed 0.20 kg/m2 for
Type 2 hoses and 0.02 kg/m2 for Type 3 hoses.) |
- |
2500 |
|
- |
Cl.6.14(When tested by the method described in Annex E, none
of the test samples shall burst at less than 8 s of the
application of the hot cube for Type 2 and 20 s for
Type 3 hose.) |
- |
1500 |
|
- |
Cl.6.15 (1)(The length shall be laid horizontally and
the central fully immersed portion of the hose shall be
visually examined for any swelling of rubber,
weathering and cracking in the rubber lining) |
- |
2500 |
|
- |
Cl.6.18(When tested in accordance with Annex H, the pressure
loss per 23 m length shall not exceed the values specified
in Table 3 at the specified flow rate and inlet pressure
(Recommendations for pressure testing of hoses in
service are given at Annex G).) |
- |
3500 |
|
- |
|
Complete
|
|
31 Dec, 2023 |
- |
2 |
IS 2097 (2012) |
Foam making branch pipe and foam inductor - Specification (Second Revision) |
-
|
9250 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
6.1 - Table 1(PERFORMANCE REQUIREMENTS-The foam making branches shall conform to the performance requirements given below 1.Pressure ) |
- |
8000 |
|
- |
6.1 - Table 1(2. Discharge Capacity(Water)) |
- |
500 |
|
- |
6.1 - Table 1(4. Throw) |
- |
500 |
|
- |
6.1 - Table 1(5. Expansion) |
- |
250 |
|
- |
|
Complete
|
|
31 Dec, 2023 |
- |
3 |
IS 8442 (2008) |
Stand post type water and foam monitor for fire fighting - Specification (First Revision) |
-
|
23500 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
3.1( Size of water monitor) |
- |
0 |
|
- |
3.2(Discharge Capacity) |
- |
0 |
|
- |
3.3(Shape of monitor) |
- |
0 |
|
- |
3.4(Components) |
- |
0 |
|
- |
5(Construction) |
- |
1500 |
|
- |
6(Workmanship and Finish) |
- |
500 |
|
- |
7(Anti-corrosive treatment) |
- |
2500 |
|
- |
8(Painting) |
- |
500 |
|
- |
9.1(Performance Requirement (water monitor)) |
- |
14000 |
|
- |
9.2(Performance Requirement (foam cum water monitor)) |
- |
14000 |
|
- |
10.1(Leakage Test) |
- |
3500 |
|
- |
10.2(Leakage Test) |
- |
0 |
|
- |
|
Complete
|
|
31 Dec, 2023 |
- |
4 |
IS 952 (2012) |
Fog nozzle for fire brigade use - Specification (Second Revision) |
-
|
- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
No Record Found
|
|
Complete
|
|
31 Dec, 2023 |
- |
5 |
IS 908 (1975) |
Specification for fire hydrant, stand post type (Second Revision) |
-
|
- View breakup
For BIS samples: 1.5 times of BIS testing charges. For others: Rs.12000/-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
No Record Found
|
|
Complete
|
|
31 Dec, 2023 |
- |
6 |
IS 905 (1980) |
Specification for delivery breechings, dividing and collecting, instantaneous pattern, for fire fighting purposes (Second Revision) |
-
|
- View breakup
Provisional testing charges-Rs.5000/-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
No Record Found
|
|
Complete
|
|
31 Dec, 2023 |
- |
7 |
IS 910 (1980) |
Specification for combined key for hydrant, hydrant cover and lower valve (Second Revision) |
-
|
- View breakup
Provisional testing charges-Rs.14000/-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
No Record Found
|
|
Complete
|
|
31 Dec, 2023 |
- |
8 |
IS 5714 (1981) |
Specification for hydrant stand - Pipe for fire fighting (First Revision) |
-
|
- View breakup
Provisional testing charges-Rs.9500/-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
No Record Found
|
|
Complete
|
|
31 Dec, 2023 |
- |
9 |
IS 904 (1983) |
Specification for 2 - Way and 4 - Way suction collecting heads for fire fighting purposes |
-
|
- View breakup
Provisional testing charges-Rs.4750/-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
No Record Found
|
|
Complete
|
|
31 Dec, 2023 |
- |
10 |
IS 907 (1984) |
Specification for suction strainers, cylindrical type for fire fighting purposes (Second Revision) |
-
|
- View breakup
Rs.10,000/-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
No Record Found
|
|
Complete
|
|
31 Dec, 2023 |
- |
11 |
IS 901 (1988) |
Specification for couplings, double male and double female instantaneous pattern for fire fighting (Third Revision) |
-
|
- View breakup
Provisional testing charges-Rs.5000/-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
No Record Found
|
|
Complete
|
|
31 Dec, 2023 |
- |
12 |
IS 906 (1988) |
Specification for revolving branch pipe for fire fighting (Third Revision) |
-
|
- View breakup
Provisional testing charges-Rs.9500/-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
No Record Found
|
|
Complete
|
|
31 Dec, 2023 |
- |
13 |
IS 4927 (1992) |
Unlined flax canvas hose for fire fighting - Specification (First Revision) |
-
|
18500 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
4(Internal diameter of hose) |
- |
500 |
|
- |
5(Length) |
- |
750 |
|
- |
6.1(Average mass per meter) |
- |
500 |
|
- |
6.1(Average mass per meter) |
- |
500 |
|
- |
6.1(Average mass per meter) |
- |
500 |
|
- |
6.1(Average mass per meter) |
- |
500 |
|
- |
7.1(Coil Diameter (Flexibility)) |
- |
500 |
|
- |
Cl. 8.1, Annexure B & Table 1(Percolation Test) |
- |
1000 |
|
- |
Cl. 8.1, Annexure B & Table 1(Percolation Test) |
- |
1000 |
|
- |
Cl. 8.1, Annexure B & Table 1(Percolation Test) |
- |
1000 |
|
- |
Cl. 8.1, Annexure B & Table 1(Percolation Test) |
- |
1000 |
|
- |
9.1(Change in size (Increase in Length)) |
- |
1250 |
|
- |
9.2(Change in size (Increase in Outer Diameter)) |
- |
1250 |
|
- |
10(Hydrostatic Proof Pressure Test) |
- |
4000 |
|
- |
11(Hydrostatic Bursting Pressure Test) |
- |
4000 |
|
- |
|
Complete
|
|
31 Dec, 2023 |
- |
14 |
IS 16018 (2012) |
Wheeled fire extinguishers - Performance and construction - Specification |
-
|
268500 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Cl 5.3(Fill Density) |
- |
1000 |
|
- |
Cl 5.4(Filling Tolerance) |
- |
1000 |
|
- |
Cl 5.5.1(Nominal Charge) |
- |
1000 |
|
- |
Cl 6.2.1(Effective Discharge Time) |
- |
500 |
|
- |
Cl 6.2.2(Bulk Range) |
- |
500 |
|
- |
Cl 6.3(Resistance To Temperature Changes) |
- |
4000 |
|
- |
Cl 6.5(Intermittent Discharge Test) |
- |
2000 |
|
- |
Cl 4(Types of Wheeled Fire Extinguishers) |
- |
0 |
|
- |
9.1(Colour) |
- |
1000 |
|
- |
8.18.3(Hose Retaining Unit) |
- |
0 |
|
- |
8.18.2(Mobility) |
- |
0.01 |
|
- |
8.18.1(Carriage Assembly) |
- |
1000 |
|
- |
8.17(Dip tubes and Filters for water based Extinguisher) |
- |
1500 |
|
- |
8.15(Safety Locking Devices) |
- |
1000 |
|
- |
8.14(Method of operation for gas cartridge type extinguishers) |
- |
1000 |
|
- |
8.14(Method of operation for carbon dioxide extinguishers) |
- |
1000 |
|
- |
8.13.3(Load test on discharge horn) |
- |
0 |
|
- |
8.13.2(Requirement to prevent loosening or detachment) |
- |
0 |
|
- |
8.13.1(Horn of carbon dioxide extinguisher) |
- |
2000 |
|
- |
8.12(Control valve test) |
- |
1000 |
|
- |
8.11.3(Requirement of burst pressure of hose assemblies for carbon dioxide fire extinguishers) |
- |
0 |
|
- |
8.11.3(Requirement of burst pressure of hose assemblies for except carbon dioxide fire extinguishers) |
- |
0 |
|
- |
8.11.2(Requirement of hose and coupling system) |
- |
0 |
|
- |
8.11.1(Requirement of the Discharge Assemblies) |
- |
2000 |
|
- |
8.9.2(Leakage Test) |
- |
0 |
|
- |
8.8(Safety and Anti-overfill devices) |
- |
1500 |
|
- |
8.7.6(Requirement of edges and surfaces) |
- |
0 |
|
- |
8.7.5(Requirement of burst test of cap,valve and closure) |
- |
0 |
|
- |
8.7.4(Requirement of collar) |
- |
0 |
|
- |
8.7.3(Requirement of filling opening diameter) |
- |
0 |
|
- |
8.7.2(Requirement of threaded connections on cylinder) |
- |
0 |
|
- |
8.7.1(Caps valves and closure) |
- |
1000 |
|
- |
8.6(Minimum wall thickness of the cylinder) |
- |
1000 |
|
- |
8.3.3(Pressure cycling Test) |
- |
3000 |
|
- |
8.3.2(Deformation Test) |
- |
1000 |
|
- |
8.3.1(Burst Test) |
- |
3000 |
|
- |
8.2(High Pressure Cylinder) |
- |
0 |
|
- |
8.1.7(Drain Plug) |
- |
0 |
|
- |
8.1.6(Thread of Plastic Components) |
- |
0 |
|
- |
8.1.4(Construction Requirement) |
- |
0 |
|
- |
8.1.3(Requirement of Welding) |
- |
0 |
|
- |
8.1.2(Leakage Observation during conditioning Test) |
- |
0 |
|
- |
7.2(Class 'B' Fire Test 233B) |
- |
80000 |
|
- |
7.2(Class 'B' Fire Test 183B) |
- |
73000 |
|
- |
7.2(Class 'B' Fire Test 144B) |
- |
62000 |
|
- |
7.2(Class 'B' Fire Test 113B) |
- |
53000 |
|
- |
7.2(Class 'B' Fire Test 89B) |
- |
45000 |
|
- |
7.2(Class 'B' Fire Test 70B) |
- |
37000 |
|
- |
7.2(Class 'B' Fire Test 55B) |
- |
30000 |
|
- |
7.2(Class 'B' Fire Test 34B) |
- |
13500 |
|
- |
7.2(Class 'B' Fire Test 21B) |
- |
9000 |
|
- |
7.2(Class 'B' Fire Test 13B) |
- |
6000 |
|
- |
7.2(Class 'B' Fire Test 8B) |
- |
4500 |
|
- |
7.2(Class 'A' Fire Test 20A) |
- |
105000 |
|
- |
7.2(Class 'A' Fire Test 15A) |
- |
80000 |
|
- |
7.2(Class 'A' Fire Test 10A) |
- |
55000 |
|
- |
7.2(Class 'A' Fire Test 6A) |
- |
32000 |
|
- |
7.2(Class 'A' Fire Test 4A) |
- |
27000 |
|
- |
7.2(Class 'A' Fire Test 3A) |
- |
18000 |
|
- |
7.2(Class 'A' Fire Test 2A) |
- |
16000 |
|
- |
7.2(Class 'A' Fire Test 1A) |
- |
14000 |
|
- |
6.7.4(Displaced Test) |
- |
0 |
|
- |
6.7.3(Nozzle Drop Test) |
- |
0 |
|
- |
6.7.1(Observation of Durability Test after Nozzle Drop Test and Displaced Test) |
- |
4000 |
|
- |
6.6.2(Internal Corrosion Test) |
- |
4000 |
|
- |
6.6.1(External Corrosion Test) |
- |
2000 |
|
- |
6.4(Retention of charge) |
- |
1000 |
|
- |
5.5.2(Gross Mass) |
- |
0 |
|
- |
3.16 and 8.1.1(Determination of maximum service pressure) |
- |
750 |
|
- |
3.19 and 8.3(Determination of Service Pressure) |
- |
750 |
|
- |
|
Complete
|
|
31 Dec, 2023 |
- |
15 |
IS 15683 (2018) |
Portable Fire Extinguishers — Performance and Construction — Specification ( First Revision ) |
-
|
291800 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Cl. 5.3.1(Filling Requirements) |
- |
200 |
|
- |
Cl. 5.3.2(Filling Requirements) |
- |
200 |
|
- |
Cl. 5.3.3(Capacities) |
- |
0 |
|
- |
Cl. 7.2 - Table 1(GENERAL OPERATING PERFORMANCE REQUIREMENTS) |
- |
500 |
|
- |
Cl. 7.3(Resistance to Temperature changes) |
- |
2000 |
|
- |
Cl 7.5.1(Impact Resistance Test) |
- |
500 |
|
- |
Cl 7.5.2(Vibration Resistance Test) |
- |
2000 |
|
- |
Cl 7.6(Resistance to Corrosion) |
- |
0 |
|
- |
Cl 7.7(Tapping Test) |
- |
1000 |
|
- |
Cl 7.8(Intermittent Discharge Test) |
- |
1000 |
|
- |
Cl 8.1(Rating Suitability for the Various Classes of Fire) |
- |
0 |
|
- |
Cl 9(CONSTRUCTION REQUIREMENTS) |
- |
0 |
|
- |
Cl 9.2.2(Burst Test) |
- |
2000 |
|
- |
Cl 9.2.3(Crushing Test) |
- |
2000 |
|
- |
Cl 9.2.4(Pressure Cycling Test) |
- |
2000 |
|
- |
Cl 9.3(Carrying Handle) |
- |
500 |
|
- |
Cl 9.4(Mounting) |
- |
500 |
|
- |
Cl 9.5(Caps, Valves and Closures) |
- |
500 |
|
- |
Cl 9.7.1(Requirements for Plastics Components) |
- |
2000 |
|
- |
Cl 9.7.2(Requirements for Plastics Components) |
- |
2000 |
|
- |
Cl 9.7.3(Requirements for Plastics Components) |
- |
2000 |
|
- |
Cl 9.8(Hose Assemblies) |
- |
1000 |
|
- |
Cl 9.9 - Table 10(Method of Operation) |
- |
200 |
|
- |
Cl 9.10(Safety-Locking Devices) |
- |
200 |
|
- |
Cl 9.11.1(Requirements for Pressure Gauges and Indicators for Low-Pressure Extinguishers) |
- |
5000 |
|
- |
Cl 9.12(Dip-Tubes and Filters — Water-Based Extinguishers) |
- |
500 |
|
- |
Cl 9.13(Horn Test for Carbon Dioxide (CO2) Extinguishers) |
- |
1000 |
|
- |
Cl 9.14(Requirements for Extinguishants Filled in the Extinguisher) |
- |
2500 |
|
For ABC = Rs. 1000/-
For BC = Rs. 500/-
For Foam = Rs. 1000/- |
Cl 9.11.3(Burst Strength Test — Gauges and Indicators) |
- |
0 |
|
- |
Cl 9.11.4(Water Resistance Test — Gauges and Indicators) |
- |
0 |
|
- |
Cl 9.11.2(Calibration Test - Gauges and Indicators) |
- |
0 |
|
- |
Cl 10(MARKING AND COLOUR) |
- |
0 |
|
- |
3.5 & 9.2.1.1(Determination of Service Pressure ) |
- |
50 |
|
- |
3.6 & 9.2.1.8(Determination of Maximum Service Pressure ) |
- |
50 |
|
- |
6.1(Determination of Test Pressure) |
- |
50 |
|
- |
6.2(Determination of Minimum Burst Pressure) |
- |
50 |
|
- |
7.4.1.(Retention of charge following partial discharge) |
- |
500 |
|
- |
7.4.2(Leakage Test) |
- |
1000 |
|
- |
7.6.1(External Corrosion Test for all types of extinguishers) |
- |
2000 |
|
- |
7.6.1(Internal Corrosion Test Test is applicable only for water based & clean agent PFEs) |
- |
2000 |
|
- |
8.1.1, 8.2.2 a) & 8.3(Class A Fire Test) |
- |
105000 |
|
1A = 10000/-
2A = 12000/-
3A = 14000/-
4A = 18000/-
6A = 30000/-
10A = 55000/-
15A = 80000/-
20A = 105000/- |
8.1.2, 8.2.2 b) & 8.4(Class B Fire Test) |
- |
80000 |
|
8B = 4500/-
13B = 6000/-
21B = 9000/-
34B = 13500/-
55B = 30000/-
70B = 37000/-
89B = 45000/-
113B = 53000/-
144B = 62000/-
183B = 73000/-
233B = 80000/- |
8.1.4 & 8.5(Class D Test fire) |
- |
16000 |
|
- |
8.1.5, 8.2.2(C) , 8.6, 8.7(Class F Splash Test) |
- |
27000 |
|
5F = 8000/-
15F = 12000/-
25F = 18000/-
75F = 27000/- |
8.8(Electrical Conductivity of Extinguishers Discharge ) |
- |
30000 |
|
- |
9.2.1.2(Construction requirement for stand vertically upright position) |
- |
500 |
|
- |
9.2.1.3(Requirement of Welding) |
- |
0 |
|
- |
9.2.1.4(Construction requirement of Neck Ring) |
- |
0 |
|
- |
9.2.1.5(Cast Analysis Certifcate) |
- |
0 |
|
- |
9.2.1.6(Type of threads on parts made of plastic component joining metal parts) |
- |
0 |
|
- |
9.2.1.7(Construction requirement for the bottom of the extinguisher) |
- |
0 |
|
- |
9.2.5.3, (Measure Thickness of the cylinder) |
- |
100 |
|
- |
9.2.6.3 (Measure Thickness of the cylinder (S.S. Body)) |
- |
100 |
|
- |
9.2.7(Measure Thickness of the cylinder (Aluminium body)) |
- |
100 |
|
- |
9.2.8(Composite Cylinder) |
- |
0 |
|
- |
9.6(Safety Device) |
- |
0 |
|
- |
Cl. 5.3.2(Filling Requirements) |
- |
0 |
|
- |
Cl. 5.3.2(Filling Requirements) |
- |
0 |
|
- |
Cl. 5.3.2(Filling Requirements) |
- |
0 |
|
- |
Cl. 5.3.2(Filling Requirements) |
- |
0 |
|
- |
Cl. 5.3.2(Filling Requirements) |
- |
0 |
|
- |
Cl. 5.3.3(Capacities) |
- |
0 |
|
- |
Cl. 5.3.3(Capacities) |
- |
0 |
|
- |
Cl. 5.3.3(Capacities) |
- |
0 |
|
- |
Cl. 5.3.3(Capacities) |
- |
0 |
|
- |
Cl. 5.3.3(Capacities) |
- |
0 |
|
- |
Cl. 7.2 - Table 1(GENERAL OPERATING PERFORMANCE REQUIREMENTS) |
- |
0 |
|
- |
Cl 7.8(Intermittent Discharge Test) |
- |
0 |
|
- |
7.6.2(Internal Corrosion Test for Extinguishers Using Water-Based Medium and Clean Agent) |
- |
4000 |
|
- |
9.14.1(Content of Mono Ammonium Phosphate) |
- |
2000 |
|
- |
9.14.3(Surface Tension of Foam Solution) |
- |
1000 |
|
- |
|
Complete
|
|
31 Dec, 2023 |
- |
16 |
IS 5290 (1993) |
Landing valves - Specification (Third Revision) |
-
|
10000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
5, 5.1 (a) fig-1, type A(Types AND DIMENSIONS) |
- |
200 |
|
- |
5, 5.1 (b) fig-2, type B(Types AND DIMENSIONS) |
- |
200 |
|
- |
5.2(Types AND DIMENSIONS) |
- |
1000 |
|
- |
6, 6.1(Finish) |
- |
300 |
|
- |
7, 7.1(7 PERFORMANCE REQUIREMENTS, Water Tightness Test for the Valve) |
- |
1500 |
|
- |
7, 7.2(hydrostatics pressure tests) |
- |
2000 |
|
- |
7, 7.3(Flow test, pressure 7 kgf/cm2) |
- |
4000 |
|
- |
6, 6.2(Finish) |
- |
500 |
|
- |
|
Complete
|
|
31 Dec, 2023 |
- |
17 |
IS 4989 (2018) |
Foam concentrate for producing mechanical foam for fire fighting - Specification (Fourth Revision) |
-
|
87000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Cl. 4.1, Table 1, Sr. No. 1 (Visual Examination ) |
- |
500 |
|
- |
Cl. 4.1, Table 1, Sr. No. 3(pH (Original Sample)) |
- |
1000 |
|
- |
Cl. 4.1, Table 1, Sr. No. 10(spreading coefficient) |
- |
1000 |
|
- |
Cl. 4.1, Table 1, Sr. No. 8(Surface tension) |
- |
500 |
|
- |
Cl. 4.1, Table 1, Sr. No. 3(pH (ageing Sample)) |
- |
1000 |
|
- |
Clause No. 4.1(General observation regarding colour and odour) |
- |
0 |
|
- |
Clause No. 4.1(General observation regarding colour and odour) |
- |
0 |
|
- |
Clause No. 4.2, Sr. No. I of Table 1, Annex-A-1(Visual Examination) |
- |
500 |
|
- |
Clause No. 4.2, Sr. No. II of Table 1, Annex-A-2(Freezing and thawing) |
- |
500 |
|
- |
Clause No. 4.2, Sr. No. III of Table 1, Annex-B(pH of original sample) |
- |
500 |
|
- |
Clause No. 4.2, Sr. No. III of Table 1, Annex-B(pH of aged sample) |
- |
500 |
|
- |
Clause No. 4.2, Sr. No. III of Table 1, Annex-B(pH of original sample) |
- |
500 |
|
- |
Clause No. 4.2, Sr. No. III of Table 1, Annex-B(pH of aged sample) |
- |
500 |
|
- |
Clause No. 4.2, Sr. No. IV of Table 1, Annex-C(Specific Gravity of original sample) |
- |
500 |
|
- |
Clause No. 4.2, Sr. No. IV of Table 1, Annex-C(Specific Gravity of aged sample) |
- |
500 |
|
- |
Clause No. 4.2, Sr. No. IV of Table 1, Annex-C(Specific Gravity of original sample) |
- |
500 |
|
- |
Clause No. 4.2, Sr. No. IV of Table 1, Annex-C(Specific Gravity of aged sample) |
- |
500 |
|
- |
Clause No. 4.2, Sr. No. IV of Table 1, Annex-C(Specific Gravity of original sample) |
- |
500 |
|
- |
Clause No. 4.2, Sr. No. IV of Table 1, Annex-C(Specific Gravity of aged sample) |
- |
500 |
|
- |
Clause No. 4.2, Sr. No. IV of Table 1, Annex-C(Specific Gravity of original sample) |
- |
500 |
|
- |
Clause No. 4.2, Sr. No. IV of Table 1, Annex-C(Specific Gravity of aged sample) |
- |
500 |
|
- |
Clause No. 4.2, Sr. No. VI of Table 1, using viscosity meter see sl No. (iv) of table 2 of IS 1206 (Part 3)(Viscosity (Kinematic)) |
- |
1000 |
|
- |
Clause No. 4.2, Sr. No. VI of Table 1, using viscosity meter see sl No. (iv) of table 2 of IS 1206 (Part 3)(Viscosity (Kinematic)) |
- |
1000 |
|
- |
Clause No. 4.2, Sr. No. VII of Table 1, Annex-E(Pour Point) |
- |
1000 |
|
- |
Clause No. 4.2, Sr. No. V of Table 1, Annex-D(Misciblity with distilled water) |
- |
500 |
|
- |
Clause No. 4.2, Sr. No. V of Table 1, Annex-D(Misciblity with synthetic sea water) |
- |
500 |
|
- |
Clause No. 4.2, Sr. No. VIII of Table 1, Annex-F(Sludge Content for Original Sample) |
- |
1000 |
|
- |
Clause No. 4.2, Sr. No. VIII of Table 1, Annex-F(Sludge Content for Aged Sample) |
- |
1000 |
|
- |
Clause No. 4.2, Sr. No. VIII of Table 1, Annex-F(Sludge Content for Original Sample) |
- |
1000 |
|
- |
Clause No. 4.2, Sr. No. VIII of Table 1, Annex-F(Sludge Content for Aged Sample) |
- |
1000 |
|
- |
Clause No. 4.2, Sr. No. IX of Table 1, Annex-G(Surface Tension) |
- |
500 |
|
- |
Clause No. 4.2, Sr. No. X of Table 1, Annex-G(Spreading Coefficient) |
- |
1000 |
|
- |
Clause No. 4.2, Sr. No. X of Table 1, Annex-G(Spreading Coefficient) |
- |
1000 |
|
- |
Clause No. 4.2, Sr. No. I of Table 2, Annex-J(Expansion) |
- |
1000 |
|
- |
Clause No. 4.2, Sr. No. I of Table 2, Annex-J(Expansion) |
- |
1000 |
|
- |
Clause No. 4.2, Sr. No. II of Table 2, Annex-J(25% Drainage Time) |
- |
500 |
|
- |
Clause No. 4.2, Sr. No. II of Table 2, Annex-J(25% Drainage Time) |
- |
500 |
|
- |
Clause No. 4.2, Sr. No. II of Table 2, Annex-J(25% Drainage Time) |
- |
500 |
|
- |
Clause No. 4.2, Sr. No. II of Table 2, Annex-J(25% Drainage Time) |
- |
500 |
|
- |
Clause No. 4.2, Sr. No. III(a) of Table 2, Annex-K(Fire Control Time for Hydrocarbon Fires (Non Polar) with potable water) |
- |
5000 |
|
- |
Clause No. 4.2, Sr. No. III(a) of Table 2, Annex-K(Fire Control Time for Hydrocarbon Fires (Non Polar) with potable water) |
- |
5000 |
|
- |
Clause No. 4.2, Sr. No. III(b) of Table 2, Annex-K(Fire Extinction Time for Hydrocarbon Fires (Non Polar) with potable water) |
- |
5000 |
|
- |
Clause No. 4.2, Sr. No. III(b) of Table 2, Annex-K(Fire Extinction Time for Hydrocarbon Fires (Non Polar) with potable water) |
- |
5000 |
|
- |
Clause No. 4.2, Sr. No. III(b) of Table 2, Annex-K(Fire Extinction Time for Hydrocarbon Fires (Non Polar) with potable water) |
- |
5000 |
|
- |
Clause No. 4.2, Sr. No. III(c) of Table 2, Annex-K(Sealability/Film forming for Hydrocarbon Fires (Non Polar) with potable water) |
- |
5000 |
|
- |
Clause No. 4.2, Sr. No. III(d) of Table 2, Annex-K(Burn Back for Hydrocarbon Fires (Non Polar) with potable water) |
- |
5000 |
|
- |
Clause No. 4.2, Sr. No. III(d) of Table 2, Annex-K(Burn Back for Hydrocarbon Fires (Non Polar) with potable water) |
- |
5000 |
|
- |
Clause No. 4.2, Sr. No. III(a) of Table 2, Annex-K(Fire Control Time for Hydrocarbon Fires (Non Polar) with synthetic sea water) |
- |
5000 |
|
- |
Clause No. 4.2, Sr. No. III(a) of Table 2, Annex-K(Fire Control Time for Hydrocarbon Fires (Non Polar) with synthetic sea water) |
- |
5000 |
|
- |
Clause No. 4.2, Sr. No. III(b) of Table 2, Annex-K(Fire Extinction Time for Hydrocarbon Fires (Non Polar) with synthetic sea water) |
- |
5000 |
|
- |
Clause No. 4.2, Sr. No. III(b) of Table 2, Annex-K(Fire Extinction Time for Hydrocarbon Fires (Non Polar) with synthetic sea water) |
- |
5000 |
|
- |
Clause No. 4.2, Sr. No. III(b) of Table 2, Annex-K(Fire Extinction Time for Hydrocarbon Fires (Non Polar) with synthetic sea water) |
- |
5000 |
|
- |
Clause No. 4.2, Sr. No. III(c) of Table 2, Annex-K(Sealability/Film forming for Hydrocarbon Fires (Non Polar) with synthetic sea water) |
- |
5000 |
|
- |
Clause No. 4.2, Sr. No. III(d) of Table 2, Annex-K(Burn Back for Hydrocarbon Fires (Non Polar) with synthetic sea water) |
- |
5000 |
|
- |
Clause No. 4.2, Sr. No. III(d) of Table 2, Annex-K(Burn Back for Hydrocarbon Fires (Non Polar) with synthetic sea water) |
- |
5000 |
|
- |
Clause No. 4.2, Sr. No. IV(a) of Table 2, Annex-M(Fire Control Time for Polar Solvent Fire) |
- |
5000 |
|
- |
Clause No. 4.2, Sr. No. IV(a) of Table 2, Annex-M(Fire Control Time for Polar Solvent Fire) |
- |
5000 |
|
- |
Clause No. 4.2, Sr. No. IV(b) of Table 2, Annex-M(Fire Extinction Time Polar Solvent Fire) |
- |
5000 |
|
- |
Clause No. 4.2, Sr. No. IV(b) of Table 2, Annex-M(Fire Extinction Time Polar Solvent Fire) |
- |
5000 |
|
- |
Clause No. 4.2, Sr. No. IV(c) of Table 2, Annex-M(Sealability/Film forming for Polar Solvent Fires) |
- |
5000 |
|
- |
Clause No. 4.2, Sr. No. IV(d) of Table 2, Annex-M(Burn Back for Polar Solvent Fires) |
- |
5000 |
|
- |
Clause No. 4.2, Sr. No. IV(d) of Table 2, Annex-M(Burn Back for Polar Solvent Fires) |
- |
5000 |
|
- |
Clause No. 4.2, Sr. No. IV(a) of Table 2, Annex-M(Fire Control Time for Polar Solvent Fire with synthetic sea water) |
- |
5000 |
|
- |
Clause No. 4.2, Sr. No. IV(a) of Table 2, Annex-M(Fire Control Time for Polar Solvent Fire with synthetic sea water) |
- |
5000 |
|
- |
Clause No. 4.2, Sr. No. IV(b) of Table 2, Annex-M(Fire Extinction Time Polar Solvent Fire with synthetic sea water) |
- |
5000 |
|
- |
Clause No. 4.2, Sr. No. IV(b) of Table 2, Annex-M(Fire Extinction Time Polar Solvent Fire with synthetic sea water) |
- |
5000 |
|
- |
Clause No. 4.2, Sr. No. IV(c) of Table 2, Annex-M(Sealability/Film forming for Polar Solvent Fires with synthetic sea water) |
- |
5000 |
|
- |
Clause No. 4.2, Sr. No. IV(d) of Table 2, Annex-M(Burn Back for Polar Solvent Fires with synthetic sea water) |
- |
5000 |
|
- |
Clause No. 4.2, Sr. No. IV(d) of Table 2, Annex-M(Burn Back for Polar Solvent Fires with synthetic sea water) |
- |
5000 |
|
- |
|
Complete
|
|
31 Dec, 2023 |
- |
18 |
IS 4308 (2019) |
Dry Chemical Powders for Fire Fighting — BC, ABC and D Types — Specification ( Third Revision ) |
-
|
49000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Clause 5 Table 1(iii)(Apparent density (Declared value by
the manufacturer)) |
- |
500 |
|
- |
Clause 5 Table 1(i)(Main Chemical constituent-Sodium/Potassium
bicarbonate
) |
- |
1500 |
|
- |
Clause 5 Table 1(iv)(Particle size / sieve analysis (Declared value by
the manufacturer)) |
- |
500 |
|
- |
Clause 5 Table 1(vi)(Water repellency) |
- |
500 |
|
- |
Clause 5 Table 1(vi)(Water repellency) |
- |
500 |
|
- |
Clause 5 Table 1(vii)(Moisture content) |
- |
500 |
|
- |
Clause 5 Table 1(viii)(Rate of flow) |
- |
500 |
|
- |
Clause 5 Table 1(ix)(Foam compatibility (required if declared by the manufacturer)) |
- |
2000 |
|
- |
Clause 5 Table 1(x)(Fire test) |
- |
30000 |
|
For A class - 12000/-
For B Class - Rs. 30000/-
For D Class - Rs. 7000/- |
Clause 5 Table 1(xi)(Temperature resistance test) |
- |
1000 |
|
- |
Clause 5 Table 1(xii)(colour) |
- |
0 |
|
- |
Clause No. 5, Sr. No. I of Table 1, Annex-A(Main Chemical Constituent of ABC Powder) |
- |
1000 |
|
- |
Clause No. 5, Sr. No. I of Table 1, Annex-A(Main Chemical Constituent for BC Powder) |
- |
500 |
|
- |
Clause No. 5, Sr. No. I of Table 1, Annex-A(Main Chemical Constituent for D Powder) |
- |
1500 |
|
- |
Clause No. 5, Sr. No. II of Table 1, Annex-A(Minimum Main Chemical Constituent for ABC Powder) |
- |
1000 |
|
- |
Clause No. 5, Sr. No. II of Table 1, Annex-A(Minimum Main Chemical Constituent for BC Powder) |
- |
500 |
|
- |
Clause No. 5, Sr. No. II of Table 1, Annex-A(Minimum Main Chemical Constituent for D Powder) |
- |
1500 |
|
- |
Clause No. 5, Sr. No. III of Table 1, Annex-B(Aparent Denisty) |
- |
500 |
|
- |
Clause No. 5, Sr. No. IV of Table 1, Annex-C(Particle Size/ Sieve Analysis) |
- |
500 |
|
- |
Clause No. 5, Sr. No. V of Table 1, Annex-D(Hygroscopicity) |
- |
500 |
|
- |
Clause No. 5, Sr. No. VI of Table 1, Annex-E(Water Repellency) |
- |
500 |
|
- |
Clause No. 5, Sr. No. VII of Table 1, Annex-F(Moisture Content) |
- |
500 |
|
- |
Clause No. 5, Sr. No. VIII of Table 1, Annex-G(Rate of flow/ Free flowing Characteristic) |
- |
500 |
|
- |
Clause No. 5, Sr. No. VIII of Table 1, Annex-G(Rate of flow/ Free flowing Characteristic for Class D Powder) |
- |
500 |
|
- |
Clause No. 5, Sr. No. IX of Table 1, Annex-H(Foam Compatibility) |
- |
2000 |
|
- |
Clause No. 5, Sr. No. X of Table 1, Annex-J(Fire test for Class 'A') |
- |
12000 |
|
- |
Clause No. 5, Sr. No. X of Table 1, Annex-J(Fire test for Class 'B') |
- |
30000 |
|
- |
Clause No. 5, Sr. No. X of Table 1, Annex-J(Fire test for Class 'D') |
- |
7000 |
|
- |
Clause No. 5, Sr. No. XI of Table 1, Annex-K(Temperature Resistance Test) |
- |
1000 |
|
- |
Clause No. 5, Sr. No. XII of Table 1(Colour of 'ABC' Powder) |
- |
0 |
|
- |
Clause No. 5, Sr. No. XII of Table 1(Colour of 'BC' Powder) |
- |
0 |
|
- |
Clause No. 5, Sr. No. XII of Table 1(Colour of 'D' Powder) |
- |
0 |
|
- |
|
Complete
|
|
31 Dec, 2023 |
- |
19 |
IS 903 (1993) |
Specification for Fire Hose Delivery Couplings, Branch Pipe, Nozzles And Nozzle Spanner - Specificaion |
-
|
10000 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
3(Finish and workmanship) |
- |
250 |
|
- |
6.3(Hydraulic test requirement) |
- |
2000 |
|
- |
6(Branch pipe) |
- |
750 |
|
- |
7(Nozzle) |
- |
500 |
|
- |
7.3(Hydraulic test requirement) |
- |
2000 |
|
- |
5.3(Size and Dimension ) |
- |
750 |
|
- |
5.4(Hydraulic test requirement) |
- |
2000 |
|
- |
5(Delivery hose coupling) |
- |
500 |
|
- |
3(Finish and workmanship) |
- |
250 |
|
- |
6(Branch pipe) |
- |
750 |
|
- |
6.3(Hydraulic test requirement) |
- |
2000 |
|
- |
7.3(Hydraulic test requirement) |
- |
2000 |
|
- |
5(Delivery hose coupling) |
- |
500 |
|
- |
5.3(Size and Dimension ) |
- |
750 |
|
- |
5.4(Hydraulic test requirement) |
- |
2000 |
|
- |
8.2(Shape & Dimensions of Spanner) |
- |
500 |
|
- |
8.4(Deflection test of Spanner) |
- |
500 |
|
- |
8.3(Coating of Nozzle Spanner) |
- |
0 |
|
- |
3(Finish and workmanship) |
- |
250 |
|
- |
7(Nozzle) |
- |
500 |
|
- |
5.3(Size and Dimension ) |
- |
750 |
|
- |
5(Delivery hose coupling) |
- |
500 |
|
- |
5.4(Hydraulic test requirement) |
- |
2000 |
|
- |
|
Complete
|
|
31 Dec, 2023 |
- |
20 |
IS 884 (1985) |
Apecification for first - Aid hose - Reel for fire fighting (First Revision) |
-
|
12750 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Cl 5.1(Dimensions) |
- |
150 |
|
- |
Cl 5.2(Resistance to Leakage) |
- |
1000 |
|
- |
Cl 5.3(Strength) |
- |
3000 |
|
- |
Cl 5.3(Strength) |
- |
3000 |
|
- |
Cl 5.4(Range & Water Flow Rate) |
- |
2500 |
|
- |
Cl 5.5(Swinging) |
- |
500 |
|
- |
Cl 5.6(Reel Action) |
- |
500 |
|
- |
Cl 6(Workmanship) |
- |
500 |
|
- |
Cl 7(Painting) |
- |
500 |
|
- |
Cl 5.1(Dimensions) |
- |
250 |
|
- |
Cl 5.1(Dimensions) |
- |
150 |
|
- |
Cl 5.1(Dimensions) |
- |
150 |
|
- |
Cl 5.1(Dimensions) |
- |
150 |
|
- |
Cl 5.1(Dimensions) |
- |
150 |
|
- |
Cl 5.1(Dimensions) |
- |
150 |
|
- |
Cl 5.1(Dimensions) |
- |
150 |
|
- |
|
Complete
|
|
31 Dec, 2023 |
- |