| 31 |
IS 4159 (2002) |
Mineral filled sheathed heating elements - Specification (Third Revision) |
- |
15000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl.6 of IS 4159:2002 &
IS 302-1:2008
(Classification) |
- |
100 |
|
15% discount to BIS |
| Cl.7 of IS 4159:2002 & IS 302-1:2008(Marking
) |
- |
500 |
|
15% discount to BIS |
| Cl.8 of IS 4159:2002 & IS 302‐1:2008(Protection Against Electric Shock) |
- |
900 |
|
15% discount to BIS |
| Cl.10 of IS 4159:2002 &
IS 302-1:2008(Input & Current) |
- |
1000 |
|
15% discount to BIS |
| Cl.11 of IS 4159:2002 & IS 302‐1:2008(Temperature Rise) |
- |
1000 |
|
15% discount to BIS |
| Cl.13 of IS 4159:2002 & IS 302-1: 2008(Electrical Insulation and Leakage Current at Operating Temperature) |
- |
750 |
|
15% discount to BIS |
| Cl.13 of IS 4159:2002 & IS 302-1: 2008(Electrical Insulation and Leakage Current at Operating Temperature) |
- |
750 |
|
15% discount to BIS |
| Cl.15 of IS 4159:2002 & IS 302-1: 2008(Moisture Resistance) |
- |
1000 |
|
15% discount to BIS |
| Cl.16 of IS 4159:2002 & IS 302-1: 2008(Insulation Resistance & Electric Strength (after Humidity Treatment)) |
- |
750 |
|
15% discount to BIS |
| Cl.16 of IS 4159:2002 & IS 302-1: 2008(Insulation Resistance & Electric Strength (after Humidity Treatment)) |
- |
750 |
|
15% discount to BIS |
| Cl.18 of IS 4159:2002(Endurance Test
) |
- |
2000 |
|
15% discount to BIS |
| Cl.19 of IS 4159:2002 & IS 302-1: 2008(Abnormal Operation) |
- |
1000 |
|
15% discount to BIS |
| Cl.20 of IS 4159:2002 & IS 302-1: 2008(Stability & Mechanical Hazards
) |
- |
500 |
|
15% discount to BIS |
| Cl.21 of IS 4159:2002 & IS 302-1: 2008(Mechanical Strength) |
- |
500 |
|
15% discount to BIS |
| Cl.22 of IS 4159:2002 &
IS 302-1: 2008(Construction) |
- |
300 |
|
15% discount to BIS |
| Cl.23 of IS 4159:2002 &
IS 302-1: 2008(Internal Wiring
) |
- |
200 |
|
15% discount to BIS |
| Cl.24 of IS 4159:2002 &
IS 302-1: 2008(Component ) |
- |
200 |
|
15% discount to BIS |
| Cl.25 of IS 4159:2002 & IS 302-1: 2008(Supply connection & external flexible cables & cords) |
- |
300 |
|
15% discount to BIS |
| Cl.26 of IS 4159:2002 & IS 302-1: 2008(Terminals for External Conductors) |
- |
200 |
|
15% discount to BIS |
| Cl.27 of IS 4159:2002 & IS 302-1: 2008(Provision for Earthing) |
- |
1000 |
|
15% discount to BIS |
| Cl.28 of IS 4159:2002 & IS 302-1: 2008(Screws & Connection ) |
- |
300 |
|
15% discount to BIS |
| Cl. 29 of IS 4159:2002 &
IS 302-1: 2008(Creepage Distances & Clearances) |
- |
1000 |
|
15% discount to BIS |
| Cl. 30 of IS 4159:2002 &
IS 302-1: 2008(Resistance to Heat, Fire and Tracking) |
- |
500 |
|
15% discount to BIS |
| Cl. 30 of IS 4159:2002 &
IS 302-1: 2008(Resistance to Heat, Fire and Tracking) |
- |
250 |
|
15% discount to BIS |
| Cl. 31 of IS 4159:2002 &
IS 302-1: 2008(Resistance to Rusting) |
- |
750 |
|
15% discount to BIS |
| Cl. 33.1 of IS 4159:2002(Finish Test
) |
- |
750 |
|
15% discount to BIS |
| Cl. 102 of IS 4159:2002(Leakage & Hydrostatic Strength Test
(for Oil heating elements)
) |
- |
750 |
|
15% discount to BIS |
|
31 Dec, 2026 |
- - |
| 32 |
IS 2082 (2018) |
Stationary storage type electric water heaters - Specification (Fifth Revision) |
- |
35000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| (Cl.15 of IS 2082:2018)(Verification of the Rated Capacity) |
- |
2500 |
|
15 % Discount to BIS |
| (Cl.16 of IS 2082:2018)(Standing Loss per 24 Hours) |
- |
2500 |
|
15 % Discount to BIS |
| (Cl.17 of IS 2082:2018)(Hot Water Output) |
- |
2500 |
|
15 % Discount to BIS |
| (Cl.18 of IS 2082:2018)( Reheating Time) |
- |
2500 |
|
15 % Discount to BIS |
| (Cl.19 of IS 2082:2018)(Mixing Factor) |
- |
500 |
|
15 % Discount to BIS |
| (Cl.20 of IS 2082:2018)(Deviation of Dial Calibration) |
- |
500 |
|
15 % Discount to BIS |
| (Cl.21 of IS 2082:2018)(Cyclic Temperature Variation) |
- |
500 |
|
15 % Discount to BIS |
| (Cl.22 of IS 2082:2018)(Finish) |
- |
500 |
|
15 % Discount to BIS |
| 7(Marking) |
- |
500 |
|
15 % Discount to BIS |
| 6(Classification ) |
- |
500 |
|
15 % Discount to BIS |
| (Cl.8 of IS 302-2-21:2011)(Protection Against Access to Live Parts) |
- |
500 |
|
15 % Discount to BIS |
| (Cl.10 of IS 302-2-21: 2011)(Power Input & Current) |
- |
1000 |
|
15 % Discount to BIS |
| (Cl.11 of 302-2-21:2011)(Heating) |
- |
1000 |
|
15 % Discount to BIS |
| (Cl.13 of IS 302-2-21:2011)(Leakage Current ) |
- |
500 |
|
15 % Discount to BIS |
| (Cl.13 of IS 302-2-21:2011)(Electrical Strength at Operating Temperature) |
- |
1000 |
|
15 % Discount to BIS |
| (Cl.14ofIS302-2-21:2011)(Transient Over Voltages) |
- |
500 |
|
15 % Discount to BIS |
| (Cl.15 of IS 302-2-21-2011)(Moisture Resistance) |
- |
1500 |
|
15 % Discount to BIS |
| (Cl.17 of IS 302-2-21:2011)(Overload protection of transformers & associated circuits) |
- |
500 |
|
15 % Discount to BIS |
| (Cl.19 of IS 302-2-21:2011)(Abnormal Operation) |
- |
500 |
|
15 % Discount to BIS |
| (Cl.20 of IS 302-2-21:2011)(Stability & Mechanical Hazards) |
- |
500 |
|
15 % Discount to BIS |
| (Cl.21ofIS302-2-21:2011)(Mechanical strength) |
- |
500 |
|
15 % Discount to BIS |
| (Cl.22 Of
IS 302-2-21:2011)(Construction) |
- |
500 |
|
15 % Discount to BIS |
| (Cl. 23 of IS 302-2-21: 2011)(Internal Wiring
) |
- |
500 |
|
15 % Discount to BIS |
| (Cl.24ofIS302-221:2011)(Component) |
- |
500 |
|
15 % Discount to BIS |
| (Cl.25 of IS 302-2-21:2011)(Supply Connection & External Flexible Cords) |
- |
500 |
|
15 % Discount to BIS |
| (Cl.26 of IS 302-2-21: 2011)(Terminals for External Conductors) |
- |
500 |
|
15 % Discount to BIS |
| (Cl.27 of IS 302-2-21:2011)(Provision for Earthing) |
- |
500 |
|
15 % Discount to BIS |
| (Cl.28 of IS 302-2-21:2011)(Screws & Connections) |
- |
500 |
|
15 % Discount to BIS |
| (Cl.29ofIS302-2-21:2011)(Clearances, Creepage Distances and Solid Insulation) |
- |
500 |
|
15 % Discount to BIS |
| (Cl.30 of IS 302-2-21:2011)(Resistance to Heat & Fire) |
- |
1000 |
|
15 % Discount to BIS |
| (Cl.31 of IS 302-2-21:2011)(Resistance to Rusting) |
- |
500 |
|
15 % Discount to BIS |
| 7.1(Marking : Rated Voltage ) |
- |
0 |
|
Refer to clause 7 |
| 7.1(Marking : Symbol for nature of supply ) |
- |
0 |
|
Refer to clause 7 |
| 7.1(Marking : Rated power input) |
- |
0 |
|
Refer to clause 7 |
| 7.1(Marking: Name, trademark or identification mark of manufacturer ) |
- |
0 |
|
Refer to clause 7 |
| 7.1(Marking: Model or type reference) |
- |
0 |
|
Refer to clause 7 |
| 7.1(Marking: Symbol for Class II) |
- |
0 |
|
Refer to clause 7 |
| 7.1(Marking: IP Number) |
- |
0 |
|
Refer to clause 7 |
| 7.1(Marking : Country of manufacture) |
- |
0 |
|
Refer to clause 7 |
| 7.1(Marking : Rated pressure) |
- |
0 |
|
Refer to clause 7 |
| 7.1(Marking : Rated capacity) |
- |
0 |
|
Refer to clause 7 |
| 7.1(Marking : Statement for a pressure-relief device) |
- |
0 |
|
Refer to clause 7 |
| 7.1(Marking : Statement for pressure reducing valve ( For rated pressure less than 0.6 MPa)) |
- |
0 |
|
Refer to clause 7 |
| 7.1(Marking : Warning for Open- outlet ) |
- |
0 |
|
Refer to clause 7 |
| 7.6(Marking : Symbol used ) |
- |
0 |
|
Refer to clause 7 |
| 7.8(Marking : Terminals ) |
- |
0 |
|
Refer to clause 7 |
| 7.11(Marking : Indication of controls ) |
- |
0 |
|
Refer to clause 7 |
| 7.13(Marking : Official language of Instruction ) |
- |
0 |
|
Refer to clause 7 |
| 7.14(Marking : Legibility and durability) |
- |
0 |
|
Refer to clause 7 |
| 7.101(Marking : Indifiction of water inlet and water outlet ) |
- |
0 |
|
Refer to clause 7 |
| Cl.8 of IS 302-2-21:2018(Protection Against Access to Live Parts) |
- |
0 |
|
Refer to clause 8 |
| Cl.10 of IS 302-2-21: 2018(Power Input & Current) |
- |
0 |
|
Refer to clause 10 |
| Cl.11 of 302-2-21:2018(Heating : Temp of Walls, ceilings and floor of the test corner ) |
- |
0 |
|
Refer to clause 11 |
| Cl.11 of 302-2-21:2018(Heating : Temp of Rubber or PVC insulation of internal and external wiring) |
- |
0 |
|
Refer to clause 11 |
| Cl.11 of 302-2-21:2018(Heating : Room Temp.) |
- |
0 |
|
Refer to clause 11 |
| Cl.13 of IS 302-2-21:2018(Leakage Current ) |
- |
0 |
|
refer to clause 13 |
| Cl.13 of IS 302-2-21:2018(3 Strength at Operating Temperature) |
- |
0 |
|
refer to clause 13 |
| Cl.14 of IS 302-2-21:2018(Transient Over Voltages) |
- |
0 |
|
refer to clause 14 |
| Cl.15 of IS 302-2-21-2018(Moisture Resistance) |
- |
0 |
|
refer to clause 15 |
| Cl.16 of IS 302-2-21-2018(Leakage current and Electric strength (After humidity): Leakage current ) |
- |
0 |
|
refer to clause 16 |
| Cl.16 of IS 302-2-21-2018(Leakage current and Electric strength (After humidity): Electric Strentgh ) |
- |
0 |
|
refer to clause 16 |
| Cl.19 of IS 302-2-21:2018(Abnormal Operation : emission of flame or molten metal or poisonous or ignitable gas ) |
- |
0 |
|
refer to clause 19 |
| Cl.19 of IS 302-2-21:2018(Abnormal Operation : Wall ceiling temp. of test corner ) |
- |
0 |
|
refer to clause 19 |
| Cl.19 of IS 302-2-21:2018(Abnormal Operation : Insulation of the supply cable or cord) |
- |
0 |
|
refer to clause 19 |
| Cl.19 of IS 302-2-21:2018(Abnormal Operation : High Voltage ) |
- |
0 |
|
refer to clause 19 |
| Cl.19 of IS 302-2-21:2018(Abnormal Operation : leakage from container during test) |
- |
0 |
|
refer to clause 19 |
| Cl.20 of IS 302-1:2008(Stability & Mechanical Hazards) |
- |
0 |
|
refer to clause 20 |
| Cl.21.1 of IS 302-1:2008(Mechanical strength : Rough handling in normal use) |
- |
21 |
|
refer to clause 21 |
| Cl.21.2 of IS 302-1:2008(Mechanical strength : prevent penetration by sharp implements. ) |
- |
0 |
|
refer to clause 21 |
| Cl.22.1 of
IS 302-1:2008(Construction : IP test ) |
- |
0 |
|
refer to clause 22 |
| Cl.22.2 of
IS 302-1:2008(Construction : Provision to ensure all pole disconnection ) |
- |
0 |
|
refer to clause 22 |
| Cl.22.6 of
IS 302-1:2008(Construction : Effect of water on 3 insulation ) |
- |
0 |
|
refer to clause 22 |
| Cl.22.6 of
IS 302-2-21:2018(Construction : Size of drain hole ) |
- |
0 |
|
refer to clause 22 |
| Cl.22.7 of
IS 302-1:2008(Construction: adequate safeguards against the risk of excessive pressure) |
- |
0 |
|
refer to clause 22 |
| Cl.22.11 of
IS 302-1:2008(Construction : Fixing of non detachable part ) |
- |
0 |
|
refer to clause 22 |
| Cl.22.12 of
IS 302-1:2008(Construction : Fixing of Handle, knob, grips, levers and similar parts) |
- |
0 |
|
refer to clause 22 |
| Cl.22.14 of
IS 302-1:2008(Construction : ragged or sharp edges) |
- |
0 |
|
refer to clause 22 |
| Cl.22.17 of
IS 302-1:2008(Construction : Spacers ) |
- |
0 |
|
refer to clause 22 |
| Cl.22.18 Of
IS 302-1:2008(Construction : Resistance to corrosion ) |
- |
0 |
|
refer to clause 22 |
| Cl 22.26 ,Cl.22.28, Cl 22.29, Cl 22.30 , Cl 22.31, Cl 22.32 of
IS 302-1:2008(Construction : Supplymentry/ double / reinforced insulation for Class II/ Class III appliance ) |
- |
0 |
|
refer to clause 22 |
| Cl.22.33 of
IS 302-1:2008(Construction : Direct contact of liquids ) |
- |
0 |
|
refer to clause 22 |
| Cl.22.34, Cl 22.35 of
IS 302-1:2008(Construction : Shaft of operating Knobs ) |
- |
0 |
|
refer to clause 22 |
| Cl.22.44 of
IS 302-1:2008(Construction : Shape and decoration of enclosure) |
- |
0 |
|
refer to clause 22 |
| Cl.22.47 of
IS 302-2-21:2018 (Construction : Water pressure test ) |
- |
0 |
|
refer to clause 22 |
| Cl.22.101 of
IS 302-2-21:2018(Construction : rated pressure of closed water heater ) |
- |
0 |
|
refer to clause 22 |
| Cl.22.102 of
IS 302-2-21:2018(Construction : repeated drawing of water temp ) |
- |
0 |
|
refer to clause 22 |
| Cl.22.103 of
IS 302-2-21:2018(Construction : Operation of Pressure relieve devices ) |
- |
0 |
|
refer to clause 22 |
| Cl.22.104 of
IS 302-2-21:2018(Construction : Outlet of open outlet heater ) |
- |
0 |
|
refer to clause 22 |
| Cl.22.106 of
IS 302-2-21:2018(Construction : Operation of thermal cut- out ) |
- |
0 |
|
refer to clause 22 |
| Cl.22.107 of
IS 302-2-21:2018(Construction : Position of Heating elements and thermal control sensor) |
- |
0 |
|
refer to clause 22 |
| Cl.22.108 of
IS 302-2-21:2018(Construction : fixing to wall ) |
- |
0 |
|
refer to clause 22 |
| Cl.22.109 of
IS 302-2-21:2018(Construction : Drain for appliance having a capacity of more than 15 liter) |
- |
0 |
|
refer to clause 22 |
| Cl.22.110 of
IS 302-2-21:2018(Construction : Material of Inner conatiner ) |
- |
0 |
|
refer to clause 22 |
| Cl.22.110 of
IS 302-2-21:2018(Construction : meterial of connections ) |
- |
0 |
|
refer to clause 22 |
| Cl.22.111 of
IS 302-2-21:2018(Construction : Resistance to vacuum ) |
- |
0 |
|
refer to clause 22 |
| Cl. 23 of IS 302-1:2008(Internal Wiring
) |
- |
0 |
|
refer to clause 23 |
| Cl. 23 of IS 302-1:2008(Internal Wiring : color identification for earthing conductor
) |
- |
0 |
|
refer to clause 23 |
| Cl.24of IS 302-221:2018(Component : Relevent Indian standards ) |
- |
0 |
|
refer to clause 24 |
| Cl.24.101 of IS302-221:2018(Component : Location of non self reseting thermal cut out ) |
- |
0 |
|
refer to clause 24 |
| Cl.24.102 of IS 302-221:2018(Component : Operation of thermal cut-out ) |
- |
0 |
|
refer to clause 24 |
| Cl.25 of IS 302-2-21:2018(Supply Connection & External Flexible Cords : connection to the supply mains) |
- |
0 |
|
refer to clause 25 |
| Cl.25.5 of IS 302-1:2008(Supply Connection & External Flexible Cords : Type of attachment ) |
- |
0 |
|
refer to clause 25 |
| Cl.25.8 of IS 302-2-21:2018(Supply Connection & External Flexible Cords : Resistance of supply cord ) |
- |
0 |
|
refer to clause 25 |
| Cl.25.10 of IS 302-1:2008(Supply Connection & External Flexible Cords : Colour of Earthing conductor ) |
- |
0 |
|
refer to clause 25 |
| Cl.25.12 of IS 302-1:2008(Supply Connection & External Flexible Cords : Moulding of supply cord ) |
- |
0 |
|
refer to clause 25 |
| Cl.25.15 of IS 302-1:2008(Supply Connection & External Flexible Cords : Cord grip test ) |
- |
0 |
|
refer to clause 25 |
| Cl.25.15 of IS 302-1:2008(Supply Connection & External Flexible Cords : Cord grip test - displacement ) |
- |
0 |
|
refer to clause 25 |
| Cl.25.18 of IS 302-1:2008(Supply Connection & External Flexible Cords) |
- |
0 |
|
refer to clause 25 |
| Cl.26 of IS 302-2-21: 2018(Terminals for External Conductors) |
- |
0 |
|
refer to clause 26 |
| Cl.27 of IS 302-2-21:2018(Provision for Earthing) |
- |
0 |
|
refer to clause 27 |
| Cl.27.5 of IS 302-1:2008(Provision for Earthing : ECR ) |
- |
0 |
|
refer to clause 27 |
| Cl.28 of IS 302-2-21:2018(Screws & Connections) |
- |
0 |
|
refer to clause 28 |
| Cl.29.1 of IS 302-1:2008(Clearances, Creepage Distances and Solid Insulation : Clearance distance ) |
- |
0 |
|
refer to clause 29 |
| Cl.29.2 of IS 302-1:2008(Clearances, Creepage Distances and Solid Insulation : Creepage distance ) |
- |
0 |
|
refer to clause 29 |
| Cl.30.1 of IS 302-1:2008(Resistance to Heat & Fire : Ball pressure test ) |
- |
0 |
|
refer to clause 30 |
| Cl.30.2 of IS 302-1:2008(Resistance to Heat & Fire : Glow wire test ) |
- |
0 |
|
refer to clause 30 |
| Cl.31 of IS 302-2-21:2018(Resistance to Rusting) |
- |
0 |
|
refer to clause 31 |
|
31 Dec, 2026 |
- Revised version included
w.e.f. 28.01.2019. |
| 33 |
IS 1293 (2019) |
Plugs and socket - Outlets of rated Voltage up to and including 250 Volts and rated current up to and including 16 amperes - Specification (Third Revision) |
- |
18000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6(Ratings) |
- |
100 |
|
15% discount to BIS |
| 7.1.1(Accessories Classification) |
- |
100 |
|
15% discount to BIS |
| 7.1.2(Accessories Classification) |
- |
100 |
|
15% discount to BIS |
| 7.1.3(Accessories Classification) |
- |
100 |
|
15% discount to BIS |
| 7.1.4(Accessories Classification) |
- |
100 |
|
15% discount to BIS |
| 7.1.5(Accessories Classification) |
- |
100 |
|
15% discount to BIS |
| 7.2.1(Socket-Outlets Classification) |
- |
100 |
|
15% discount to BIS |
| 7.2.2(Socket-Outlets Classification) |
- |
100 |
|
15% discount to BIS |
| 7.2.3(Socket-Outlets Classification) |
- |
100 |
|
15% discount to BIS |
| 7.2.4(Socket-Outlets Classification) |
- |
100 |
|
15% discount to BIS |
| 7.3(Plug Classification) |
- |
100 |
|
15% discount to BIS |
| 8.1(MARKING) |
- |
100 |
|
15% discount to BIS |
| 8.8(MARKING) |
- |
100 |
|
15% discount to BIS |
| 8.9(MARKING) |
- |
200 |
|
15% discount to BIS |
| 9.1(CHECKING OF DIMENSIONS) |
- |
100 |
|
15% discount to BIS |
| 9.2(CHECKING OF DIMENSIONS) |
- |
200 |
|
15% discount to BIS |
| 10.1(PROTECTION AGAINST ELECTRIC SHOCK) |
- |
100 |
|
15% discount to BIS |
| 10.3(PROTECTION AGAINST ELECTRIC SHOCK) |
- |
200 |
|
15% discount to BIS |
| 10.4(PROTECTION AGAINST ELECTRIC SHOCK) |
- |
200 |
|
15% discount to BIS |
| 10.5(PROTECTION AGAINST ELECTRIC SHOCK) |
- |
200 |
|
15% discount to BIS |
| 10.6(PROTECTION AGAINST ELECTRIC SHOCK) |
- |
200 |
|
15% discount to BIS |
| 10.7(PROTECTION AGAINST ELECTRIC SHOCK) |
- |
200 |
|
15% discount to BIS |
| 11.1(PROVISIONS FOR EARTHING) |
- |
200 |
|
15% discount to BIS |
| 11.2(PROVISIONS FOR EARTHING) |
- |
200 |
|
15% discount to BIS |
| 11.3(PROVISIONS FOR EARTHING) |
- |
200 |
|
15% discount to BIS |
| 11.4(PROVISIONS FOR EARTHING) |
- |
200 |
|
15% discount to BIS |
| 11.5(PROVISIONS FOR EARTHING) |
- |
200 |
|
15% discount to BIS |
| 11.6(PROVISIONS FOR EARTHING) |
- |
100 |
|
15% discount to BIS |
| 12.1.1(TERMINALS) |
- |
100 |
|
15% discount to BIS |
| 12.1.2(TERMINALS) |
- |
100 |
|
15% discount to BIS |
| 12.2.1(TERMINALS) |
- |
100 |
|
15% discount to BIS |
| 12.2.2(TERMINALS) |
- |
100 |
|
15% discount to BIS |
| 12.2.3(TERMINALS) |
- |
100 |
|
15% discount to BIS |
| 12.2.4(TERMINALS) |
- |
100 |
|
15% discount to BIS |
| 12.2.5(TERMINALS) |
- |
100 |
|
15% discount to BIS |
| 12.2.6(TERMINALS) |
- |
100 |
|
15% discount to BIS |
| 12.2.7(TERMINALS) |
- |
100 |
|
15% discount to BIS |
| 12.2.8(TERMINALS) |
- |
100 |
|
15% discount to BIS |
| 12.2.9(TERMINALS) |
- |
100 |
|
15% discount to BIS |
| 12.2.10(TERMINALS) |
- |
100 |
|
15% discount to BIS |
| 12.2.11(TERMINALS) |
- |
100 |
|
15% discount to BIS |
| 12.3.1(TERMINALS) |
- |
100 |
|
15% discount to BIS |
| 12.3.2(TERMINALS) |
- |
100 |
|
15% discount to BIS |
| 12.3.3(TERMINALS) |
- |
100 |
|
15% discount to BIS |
| 12.3.4(TERMINALS) |
- |
100 |
|
15% discount to BIS |
| 12.3.5(TERMINALS) |
- |
100 |
|
15% discount to BIS |
| 12.3.6(TERMINALS) |
- |
100 |
|
15% discount to BIS |
| 12.3.7(TERMINALS) |
- |
100 |
|
15% discount to BIS |
| 12.3.8(TERMINALS) |
- |
100 |
|
15% discount to BIS |
| 12.3.9(TERMINALS) |
- |
100 |
|
15% discount to BIS |
| 12.3.10(TERMINALS) |
- |
100 |
|
15% discount to BIS |
| 12.3.11(TERMINALS) |
- |
100 |
|
15% discount to BIS |
| 12.3.12(TERMINALS) |
- |
100 |
|
15% discount to BIS |
| 13.1(CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
50 |
|
15% discount to BIS |
| 13.2(CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
50 |
|
15% discount to BIS |
| 13.3(CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
50 |
|
15% discount to BIS |
| 13.4(CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
50 |
|
15% discount to BIS |
| 13.5(CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
50 |
|
15% discount to BIS |
| 13.6(CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
50 |
|
15% discount to BIS |
| 13.7(CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
50 |
|
15% discount to BIS |
| 13.8(CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
50 |
|
15% discount to BIS |
| 13.9(CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
50 |
|
15% discount to BIS |
| 13.1(CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
50 |
|
15% discount to BIS |
| 13.11(CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
50 |
|
15% discount to BIS |
| 13.12(CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
50 |
|
15% discount to BIS |
| 13.13(CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
50 |
|
15% discount to BIS |
| 13.14(CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
50 |
|
15% discount to BIS |
| 13.15(CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
50 |
|
15% discount to BIS |
| 13.16(CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
50 |
|
15% discount to BIS |
| 13.17(CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
50 |
|
15% discount to BIS |
| 13.18(CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
50 |
|
15% discount to BIS |
| 13.19(CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
50 |
|
15% discount to BIS |
| 13.2(CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
50 |
|
15% discount to BIS |
| 13.21(CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
50 |
|
15% discount to BIS |
| 13.22(CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
50 |
|
15% discount to BIS |
| 13.23(CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
50 |
|
15% discount to BIS |
| 14.1(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
50 |
|
15% discount to BIS |
| 14.2(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
50 |
|
15% discount to BIS |
| 14.3(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
50 |
|
15% discount to BIS |
| 14.4(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
50 |
|
15% discount to BIS |
| 14.5(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
50 |
|
15% discount to BIS |
| 14.6(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
50 |
|
15% discount to BIS |
| 14.7(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
50 |
|
15% discount to BIS |
| 14.8(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
50 |
|
15% discount to BIS |
| 14.9(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
50 |
|
15% discount to BIS |
| 14.1(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
50 |
|
15% discount to BIS |
| 14.11(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
50 |
|
15% discount to BIS |
| 14.12(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
50 |
|
15% discount to BIS |
| 14.13(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
50 |
|
15% discount to BIS |
| 14.14(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
50 |
|
15% discount to BIS |
| 14.15(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
50 |
|
15% discount to BIS |
| 14.16(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
50 |
|
15% discount to BIS |
| 14.17(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
50 |
|
15% discount to BIS |
| 14.18(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
50 |
|
15% discount to BIS |
| 14.19(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
50 |
|
15% discount to BIS |
| 14.2(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
50 |
|
15% discount to BIS |
| 14.21(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
50 |
|
15% discount to BIS |
| 14.22(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
50 |
|
15% discount to BIS |
| 14.23(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
50 |
|
15% discount to BIS |
| 14.23.1(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
50 |
|
15% discount to BIS |
| 14.23.2(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
50 |
|
15% discount to BIS |
| 14.24(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
50 |
|
15% discount to BIS |
| 14.25(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
50 |
|
15% discount to BIS |
| 14.26(CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
50 |
|
15% discount to BIS |
| 15(INTERLOCKED SOCKET-OUTLETS) |
- |
500 |
|
15% discount to BIS |
| 16.1(RESISTANCE TO AGEING,) |
- |
1000 |
|
15% discount to BIS |
| 16.2(RESISTANCE TO HARMFUL INGRESS OF WATER AND TO HUMIDITY) |
- |
500 |
|
15% discount to BIS |
| 16.3(Resistance to Humidity) |
- |
500 |
|
15% discount to BIS |
| 17.1(INSULATION RESISTANCE AND ELECTRIC STRENGTH) |
- |
1000 |
|
15% discount to BIS |
| 17.2(INSULATION RESISTANCE AND ELECTRIC STRENGTH) |
- |
500 |
|
15% discount to BIS |
| 17.3(INSULATION RESISTANCE AND ELECTRIC STRENGTH) |
- |
500 |
|
15% discount to BIS |
| 18(OPERATION OF EARTHING CONTACTS) |
- |
500 |
|
15% discount to BIS |
| 19(TEMPERATURE RISE) |
- |
2000 |
|
15% discount to BIS |
| 20(BREAKING CAPACITY) |
- |
1500 |
|
15% discount to BIS |
| 21(NORMAL OPERATION) |
- |
500 |
|
15% discount to BIS |
| 22.1(Verification of the Maximum Withdrawal Force) |
- |
250 |
|
15% discount to BIS |
| 22.2(Verification of Minimum Withdrawal Force) |
- |
250 |
|
15% discount to BIS |
| 23.1(FLEXIBLE CABLES AND THEIR CONNECTION) |
- |
100 |
|
15% discount to BIS |
| 23.3(FLEXIBLE CABLES AND THEIR CONNECTION) |
- |
200 |
|
15% discount to BIS |
| 23.4(FLEXIBLE CABLES AND THEIR CONNECTION) |
- |
200 |
|
15% discount to BIS |
| 24.1(MECHANICAL STRENGTH
For all kinds of fixed socket-outlets
) |
- |
50 |
|
15% discount to BIS |
| 24.2(MECHANICAL STRENGTH
For portable single socket-outlets:
1) with enclosures, covers or bodies other than thermoplastic or elastomeric material) |
- |
50 |
|
15% discount to BIS |
| 24.3(MECHANICAL STRENGTH
for fixed socket-outlets with a main part intended to be mounted directly on a surface) |
- |
50 |
|
15% discount to BIS |
| 24.4(MECHANICAL STRENGTH
For Plug
1) with enclosures, covers and bodies of elastomeric or thermoplastic material) |
- |
50 |
|
15% discount to BIS |
| 24.5(MECHANICAL STRENGTH
For portable single socket-outlets:
1) with enclosures, covers or bodies of thermoplastic or elastomeric material) |
- |
50 |
|
15% discount to BIS |
| 24.6(MECHANICAL STRENGTH
For screwed glands of accessories having an IP code higher than IP20) |
- |
50 |
|
15% discount to BIS |
| 24.7(MECHANICAL STRENGTH
For plug pins provided with insulating sleeves) |
- |
50 |
|
15% discount to BIS |
| 24.8(MECHANICAL STRENGTH
For shuttered socket-outlets) |
- |
50 |
|
15% discount to BIS |
| 24.9(MECHANICAL STRENGTH
For portable multiple and combined socket outlets
(1) with enclosures, covers or bodies other than thermoplastic or elastomeric material) |
- |
50 |
|
15% discount to BIS |
| 24.1(MECHANICAL STRENGTH
For Plug
(1) with enclosures, covers or bodies other than thermoplastic or elastomeric material) |
- |
50 |
|
15% discount to BIS |
| 24.11(MECHANICAL STRENGTH
For portable socket-outlets having means for suspension on a wall) |
- |
50 |
|
15% discount to BIS |
| 24.12(MECHANICAL STRENGTH
For portable socket-outlets having means for suspension on a wall) |
- |
50 |
|
15% discount to BIS |
| 24.13(MECHANICAL STRENGTH
For portable socket-outlets having means for suspension on a wall) |
- |
50 |
|
15% discount to BIS |
| 24.14.1(MECHANICAL STRENGTH
For fixed socket-outlets) |
- |
50 |
|
15% discount to BIS |
| 24.14.2(MECHANICAL STRENGTH
For fixed socket-outlets) |
- |
50 |
|
15% discount to BIS |
| 24.14.3(MECHANICAL STRENGTH
For plugs and portable socket-outlets) |
- |
50 |
|
15% discount to BIS |
| 24.15(MECHANICAL STRENGTH
) |
- |
50 |
|
15% discount to BIS |
| 24.16(MECHANICAL STRENGTH
For shroud of portable socket-outlets) |
- |
50 |
|
15% discount to BIS |
| 25.1(RESISTANCE TO HEAT
Accessories and surface mounting boxes) |
- |
250 |
|
15% discount to BIS |
| 25.2(RESISTANCE TO HEAT
Parts of insulating material necessary to retain
current-carrying parts of the earthing circuit in position,
as well as parts of the front surface zone of thermoplastic material) |
- |
250 |
|
15% discount to BIS |
| 25.3(RESISTANCE TO HEAT
Parts of insulating material not necessary to retain current-carrying parts and parts of the earthing circuit in position, even though they are in contact with them) |
- |
250 |
|
15% discount to BIS |
| 25.4(RESISTANCE TO HEAT
) |
- |
250 |
|
15% discount to BIS |
| 26.1(SCREWS, CURRENT-CARRYING PARTS AND CONNECTIONS) |
- |
100 |
|
15% discount to BIS |
| 26.2(SCREWS, CURRENT-CARRYING PARTS AND CONNECTIONS) |
- |
100 |
|
15% discount to BIS |
| 26.3(SCREWS, CURRENT-CARRYING PARTS AND CONNECTIONS) |
- |
100 |
|
15% discount to BIS |
| 26.4(SCREWS, CURRENT-CARRYING PARTS AND CONNECTIONS) |
- |
100 |
|
15% discount to BIS |
| 26.5(SCREWS, CURRENT-CARRYING PARTS AND CONNECTIONS) |
- |
100 |
|
15% discount to BIS |
| 26.6(SCREWS, CURRENT-CARRYING PARTS AND CONNECTIONS) |
- |
100 |
|
15% discount to BIS |
| 26.7(SCREWS, CURRENT-CARRYING PARTS AND CONNECTIONS) |
- |
100 |
|
15% discount to BIS |
| 27.1(CREEPAGE DISTANCES, CLEARANCES AND DISTANCES THROUGH SEALING COMPOUND) |
- |
150 |
|
15% discount to BIS |
| 27.2(CREEPAGE DISTANCES, CLEARANCES AND DISTANCES THROUGH SEALING COMPOUND) |
- |
150 |
|
15% discount to BIS |
| 27.3(CREEPAGE DISTANCES, CLEARANCES AND DISTANCES THROUGH SEALING COMPOUND) |
- |
200 |
|
15% discount to BIS |
| 28.1.1(Resistance to Abnormal Heat and to Fire
Glow-Wire Test) |
- |
250 |
|
15% discount to BIS |
| 28.1.2(Resistance to Abnormal Heat and to Fire
for plugs with pins provided with insulating sleeves) |
- |
250 |
|
15% discount to BIS |
| 28.2(Resistance to Tracking
For accessories other than IP code higher than IPX0 parts of insulating material retaining live parts in position) |
- |
500 |
|
15% discount to BIS |
| 29(RESISTANCE TO RUSTING) |
- |
500 |
|
15% discount to BIS |
| 30.1(ADDITIONAL TESTS ON PINS PROVIDED WITH INSULATING SLEEVES
Pressure Test at High Temperature) |
- |
150 |
|
15% discount to BIS |
| 30.2(ADDITIONAL TESTS ON PINS PROVIDED WITH INSULATING SLEEVES
Static Damp Heat Test) |
- |
150 |
|
15% discount to BIS |
| 30.3(ADDITIONAL TESTS ON PINS PROVIDED WITH INSULATING SLEEVES
Tests at Low Temperature) |
- |
100 |
|
15% discount to BIS |
| 30.4(ADDITIONAL TESTS ON PINS PROVIDED WITH INSULATING SLEEVES
Impact Test at Low Temperature) |
- |
100 |
|
15% discount to BIS |
| 23.2(FLEXIBLE CABLES AND THEIR CONNECTION) |
- |
100 |
|
15% discount to BIS |
| 8.2(Marking) |
- |
100 |
|
15% discount to BIS |
| 8.3(Marking) |
- |
100 |
|
15% discount to BIS |
| 8.4(Marking) |
- |
100 |
|
15% discount to BIS |
| 8.5(Marking) |
- |
100 |
|
15% discount to BIS |
| 8.6(Marking) |
- |
100 |
|
15% discount to BIS |
| 8.7(Marking) |
- |
100 |
|
15% discount to BIS |
| 10.2(PROTECTION AGAINST ELECTRIC SHOCK) |
- |
100 |
|
15% discount to BIS |
| 24.17(MECHANICAL STRENGTH) |
- |
100 |
|
15% discount to BIS |
| 24.18(MECHANICAL STRENGTH) |
- |
100 |
|
15% discount to BIS |
| 24.19(MECHANICAL STRENGTH) |
- |
100 |
|
15% discount to BIS |
| 21(NORMAL OPERATION) |
- |
500 |
|
15% discount to BIS |
|
31 Dec, 2026 |
- Included w.e.f. 24-07-2020. |
| 34 |
IS 369 (2019) |
Household electric direct - Acting room heaters - Performance requirements (Fourth Revision) |
Not Applicable |
15000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl.6 of IS 302-2-30:2007(Classification) |
- |
100 |
|
15% discount to BIS |
| Cl.7 of IS 302-2-30:2007 &IS:302-1:2008(Marking and Instructions) |
- |
100 |
|
15% discount to BIS |
| Cl.8 of IS 302-2-30:2007 &IS:302-1:2008(Protection Against Access to Live Parts) |
- |
100 |
|
15% discount to BIS |
| Cl.10 of IS 302-2-30:2007 &IS:302-1:2008(Power Input and Current) |
- |
100 |
|
15% discount to BIS |
| Cl.11 of IS 302-2-30:2007 &IS:302-1:2008(Heating) |
- |
100 |
|
15% discount to BIS |
| Cl.13 of IS 302-2-30:2007 &IS:302-1:2008(Leakage Current & Electric Strength at operating temp) |
- |
100 |
|
15% discount to BIS |
| Cl.14 of IS 302-2-30:2007 &IS:302-1:2008(Transient Over Voltages) |
- |
100 |
|
15% discount to BIS |
| Cl.15 of IS 302-2-30:2007 &IS:302-1:2008(Moisture Resistance) |
- |
100 |
|
15% discount to BIS |
|
31 Dec, 2026 |
- - |
| 35 |
IS 368 (2014) |
Electric immersion water heaters - Specification (Fifth Revision) |
Not Applicable |
15000 View breakup
Rs. 15000/-
[15% discount to BIS]
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl.6 of IS 302-‐2-‐201:2008(Classification) |
- |
100 |
|
15% discount to BIS |
| Cl.7 of IS 302-2-201:2008(Marking and Instruction ) |
- |
100 |
|
15% discount to BIS |
| Cl.8 of IS 302‐2-201: 2008(Protection Against Access to Live Parts) |
- |
100 |
|
15% discount to BIS |
| Cl.10 of IS 302‐2‐201:2008(Power Input and Current ) |
- |
500 |
|
15% discount to BIS |
| Cl.11 of IS 302-2201: 2008(Heating) |
- |
1000 |
|
15% discount to BIS |
| Cl. 12 of IS 368:2014(Operation under overload conditions of appliances with heating elements) |
- |
4000 |
|
15% discount to BIS |
| Cl.13 of IS 302-2-201: 2008(Leakage Current & Electric Strength at Operating Temperature) |
- |
500 |
|
15% discount to BIS |
| Cl.14 of IS 302‐2-201:2008(Transient Over Voltages ) |
- |
100 |
|
15% discount to BIS |
| Cl.15 of IS 302-2-201:2008(Moisture Resistance ) |
- |
500 |
|
15% discount to BIS |
| Cl.16 of IS 302-2-201:2008(Leakage Current & Electric Strength) |
- |
500 |
|
15% discount to BIS |
| Cl.17 of IS 302‐2-201: 2008(Overload Protection of Transformers & Associated Circuits) |
- |
500 |
|
15% discount to BIS |
| Cl.18 of IS 368:2014(Endurance) |
- |
6000 |
|
15% discount to BIS |
| Cl.19 of IS 302‐2-201: 2008(Abnormal Operation ) |
- |
3000 |
|
15% discount to BIS |
| Cl.20 of IS 302-2-201: 2008(Stability & Mechanical Hazards) |
- |
100 |
|
15% discount to BIS |
| Cl.21 of IS 302-2-201: 2008(Mechanical Strength ) |
- |
100 |
|
15% discount to BIS |
| Cl.22 of IS 302-2-201: 2008(Construction) |
- |
2000 |
|
15% discount to BIS |
| Cl.23 of 302-2-201:2008(Internal Wiring ) |
- |
100 |
|
15% discount to BIS |
| Cl.24 of IS 302-2-201: 2008(Component) |
- |
100 |
|
15% discount to BIS |
| Cl.25 of IS 302-2-201: 2008(Supply Connection and External Flexible Cords) |
- |
100 |
|
15% discount to BIS |
| Cl.26 of IS 302-2-201: 2008(Terminals for External Conductors) |
- |
100 |
|
15% discount to BIS |
| Cl.27 of IS 302-2-201: 2008(Provision for Earthing ) |
- |
100 |
|
15% discount to BIS |
| Cl.28 of IS 302-2-201: 2008(Screws & Connections ) |
- |
100 |
|
15% discount to BIS |
| Cl.29 of IS 302-2‐201:2008(Clearances, Creepage Distances and Solid Insulation ) |
- |
100 |
|
15% discount to BIS |
| Cl.30 of IS 302-2‐201:2008(Resistance to Heat and Fire ) |
- |
100 |
|
15% discount to BIS |
| Cl.31 of IS 302-2-201:2008(Resistance of Rusting ) |
- |
100 |
|
15% discount to BIS |
| Cl.32 of IS 302-2-201:2008(Radiation, Toxicity and Similar Hazards) |
- |
100 |
|
15% discount to BIS |
|
31 Dec, 2026 |
- - |
| 36 |
IS 302 : Part 2 : Sec 201 (2008) |
Safety of household and similar electrical appliances: Part 2 particular requirements: Sec 201 electric immersion water heaters (First Revision) |
Not Applicable |
15000 View breakup
Rs. 15000/-
[15% discount to BIS]
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl.6 of IS 302-‐2-‐201:2008(Classification) |
- |
100 |
|
15 % Discount to BIS |
| Cl.7 of IS 302-2-201:2008(Marking and Instruction ) |
- |
400 |
|
15 % Discount to BIS |
| Cl.8 of IS 302‐2-201: 2008(Protection Against Access to Live Parts) |
- |
500 |
|
15 % Discount to BIS |
| Cl.10 of IS 302‐2‐201:2008(Power Input and Current ) |
- |
1000 |
|
15 % Discount to BIS |
| Cl.11 of IS 302-2201: 2008(Heating) |
- |
1000 |
|
15 % Discount to BIS |
| Cl.13 of IS 302-2-201: 2008(Leakage Current & Electric Strength at Operating Temperature) |
- |
1500 |
|
15 % Discount to BIS |
| Cl.14 of IS 302‐2-201:2008(Transient Over Voltages ) |
- |
500 |
|
15 % Discount to BIS |
| Cl.15 of IS 302-2-201:2008(Moisture Resistance ) |
- |
1500 |
|
15 % Discount to BIS |
| Cl.16 of IS 302-2-201:2008(Leakage Current & Electric Strength) |
- |
500 |
|
15 % Discount to BIS |
| Cl.17 of IS 302‐2-201: 2008(Overload Protection of Transformers & Associated Circuits) |
- |
500 |
|
15 % Discount to BIS |
| Cl.19 of IS 302‐2-201: 2008(Abnormal Operation ) |
- |
500 |
|
15 % Discount to BIS |
| Cl.20 of IS 302-2-201: 2008(Stability & Mechanical Hazards) |
- |
500 |
|
15 % Discount to BIS |
| Cl.21 of IS 302-2-201: 2008(Mechanical Strength ) |
- |
500 |
|
15 % Discount to BIS |
| Cl.22 of IS 302-2-201: 2008(Construction) |
- |
500 |
|
15 % Discount to BIS |
| Cl.23 of 302-2-201:2008(Internal Wiring ) |
- |
500 |
|
15 % Discount to BIS |
| Cl.24 of IS 302-2-201: 2008(Component) |
- |
500 |
|
15 % Discount to BIS |
| Cl.25 of IS 302-2-201: 2008(Supply Connection and External Flexible Cords) |
- |
500 |
|
15 % Discount to BIS |
| Cl.26 of IS 302-2-201: 2008(Terminals for External Conductors) |
- |
500 |
|
15 % Discount to BIS |
| Cl.27 of IS 302-2-201: 2008(Provision for Earthing ) |
- |
500 |
|
15 % Discount to BIS |
| Cl.28 of IS 302-2-201: 2008(Screws & Connections ) |
- |
500 |
|
15 % Discount to BIS |
| Cl.29 of IS 302-2‐201:2008(Clearances, Creepage Distances and Solid Insulation ) |
- |
500 |
|
15 % Discount to BIS |
| Cl.30 of IS 302-2‐201:2008(Resistance to Heat and Fire ) |
- |
1000 |
|
15 % Discount to BIS |
| Cl.31 of IS 302-2-201:2008(Resistance of Rusting ) |
- |
500 |
|
15 % Discount to BIS |
| Cl.32 of IS 302-2-201:2008(Radiation, Toxicity and Similar Hazards) |
- |
500 |
|
15 % Discount to BIS |
|
31 Dec, 2026 |
- - |
| 37 |
IS 302 : Part 2 : Sec 30 (2007) |
Safety of household and similar electrical appliances: Part 2 particular requirements: Sec 30 room heaters (First Revision) |
Not Applicable |
15000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl.6 (Classification) |
- |
100 |
|
15 % Discount to BIS |
| Cl.7.1 of IS:302-1:2008(Marking and Instructions : Rated Voltage ) |
- |
25 |
|
15 % Discount to BIS |
| Cl.7.1 of IS:302-1:2008(Marking and Instructions : Nature of supply ) |
- |
25 |
|
15 % Discount to BIS |
| Cl.7.1 of IS:302-1:2008(Marking and Instructions : rated power input ) |
- |
25 |
|
15 % Discount to BIS |
| Cl.7.1 of IS:302-1:2008(Marking and Instructions : Name , trade-mark or identification mark of the manufacturer ) |
- |
25 |
|
15 % Discount to BIS |
| Cl.7.1 of IS:302-1:2008(Marking and Instructions : Model or type ) |
- |
25 |
|
15 % Discount to BIS |
| Cl.7.1 of IS:302-1:2008(Marking and Instructions : Symbol for Class-II ) |
- |
25 |
|
15 % Discount to BIS |
| Cl.7.1 of IS:302-1:2008(Marking and Instructions : Country of manufacture ) |
- |
25 |
|
15 % Discount to BIS |
| Cl 7.1 & Cl.7.6 of IS:302-2:30: 2007(Marking and Instructions : Do not cover ) |
- |
25 |
|
15 % Discount to BIS |
| Cl.7.5 of IS:302-1:2008(Marking and Instructions : upper of lower limit of the rated power input ) |
- |
25 |
|
15 % Discount to BIS |
| Cl.7.6 of IS:302-1:2008(Marking and Instructions : Symbols ) |
- |
25 |
|
15 % Discount to BIS |
| Cl.7.8 of IS :302-1:2008(Marking and Instructions : terminals ) |
- |
25 |
|
15 % Discount to BIS |
| Cl.7.9 of IS :302-1:2008(Marking and Instructions : switches ) |
- |
25 |
|
15 % Discount to BIS |
| Cl.7.11 of IS :302-1:2008(Marking and Instructions : Controls ) |
- |
25 |
|
15 % Discount to BIS |
| Cl.7.13 of IS 302-1:2008(Marking and Instructions : Languge of instruction and texts ) |
- |
25 |
|
15 % Discount to BIS |
| Cl.7.14 of IS302-1:2008(Marking and Instructions : Legibility and durability ) |
- |
25 |
|
15 % Discount to BIS |
| Cl.7.14 of IS:302-2:30: 2007(Marking and Instructions : height of symbol) |
- |
25 |
|
15 % Discount to BIS |
| Cl.7.14 of IS:302-2:30: 2007(Marking and Instructions : Height of “Do not cover”) |
- |
25 |
|
15 % Discount to BIS |
| Cl.7.15 of IS 302-1:2008(Marking and Instructions : discernibility from the out side ) |
- |
25 |
|
15 % Discount to BIS |
| Cl.7.15 of IS 302-1:2008(Marking and Instructions : Visibility of marking concerning covering) |
- |
25 |
|
15 % Discount to BIS |
| Cl.7.101 of IS:302-2:30: 2007(Marking and Instructions : standard mark. ) |
- |
25 |
|
15 % Discount to BIS |
| Cl.8 of IS:302-1:2008(Protection Against Access to Live Parts) |
- |
500 |
|
15 % Discount to BIS |
| Cl.10 of IS:302-1:2008(Power Input and Current) |
- |
900 |
|
15 % Discount to BIS |
| Cl.11 of IS:302-2:30: 2007(Heating : PVC Insulation ) |
- |
250 |
|
15 % Discount to BIS |
| Cl.11 of IS:302-2:30: 2007(Heating : Wooden supports, walls, ceiling and floor of the test corner) |
- |
250 |
|
15 % Discount to BIS |
| Cl.11 of IS:302-2:30: 2007(Heating : Surfaces of handles, knobs, grips and similar parts) |
- |
100 |
|
15 % Discount to BIS |
| Cl.11 of IS:302-2:30: 2007(Heating : Air-outlet grills) |
- |
100 |
|
15 % Discount to BIS |
| Cl.11 of IS:302-2:30: 2007(Heating : Temperature rise in winding) |
- |
100 |
|
15 % Discount to BIS |
| Cl.11.8 of IS:302-2:30: 2007(Heating : For liquid filled radiators the temp. rise of the outer surface of the liquid container) |
- |
100 |
|
15 % Discount to BIS |
| Cl.11 of IS:302-2:30: 2007(Heating : Room temperature) |
- |
100 |
|
15 % Discount to BIS |
| Cl.13 of IS:302-1:2008(Leakage Current of Electric Strength at operating temp. ) |
- |
750 |
|
15 % Discount to BIS |
| Cl.13 of IS:302-1:2008(Leakage Current of Electric Strength at operating temp. ) |
- |
750 |
|
15 % Discount to BIS |
| Cl.14 of IS:302-1:2008(Transient Over Voltages) |
- |
500 |
|
15 % Discount to BIS |
| Cl.15 of IS 302-1:2008(Moisture Resistance
) |
- |
1500 |
|
15 % Discount to BIS |
| Cl.16 of IS:302-1:2008(Leakage current and Electric strength (After humidity): Leakage current ) |
- |
250 |
|
15 % Discount to BIS |
| Cl.16 of IS:302-1:2008(Leakage current and Electric strength (After humidity): Electric Strentgh ) |
- |
250 |
|
15 % Discount to BIS |
| Cl.19 of IS:302-1:2008(Abnormal Operation : Emission of molten or poisonous or ignitable gas) |
- |
50 |
|
15 % Discount to BIS |
| Cl.17 & IS:302-1:2008(Over load Protection of Transformers and Associated Circuits ) |
- |
50 |
|
15 % Discount to BIS |
| Cl.19 of IS:302-2-30:2007(Abnormal Operation : Temp rise of test corner ) |
- |
50 |
|
15 % Discount to BIS |
| Cl.19 of IS:302-2-30:2007(Abnormal Operation : temp rise of supply cord ) |
- |
50 |
|
15 % Discount to BIS |
| Cl.19 of IS:302-2-30:2007(Abnormal Operation : High Voltage ) |
- |
50 |
|
15 % Discount to BIS |
| Cl.19.103 , Cl 19.104 of IS:302-2-30:2007(Abnormal Operation : Operation after Covering by cotton) |
- |
50 |
|
15 % Discount to BIS |
| Cl.19.106 of IS:302-2-30:2007(Abnormal Operation : Locked rotor of fan hetear ) |
- |
50 |
|
15 % Discount to BIS |
| Cl.19.109 of IS:302-2-30:2007(Abnormal Operation : operation against wall for fan heater ) |
- |
50 |
|
15 % Discount to BIS |
| Cl.19.110 of IS:302-2-30:2007(Abnormal Operation : operation against wall for visibly glowing radiant heaters ) |
- |
50 |
|
15 % Discount to BIS |
| Cl.19.111 of IS:302-2-30:2007(Abnormal Operation : Ignition of flannelette for Visibly glowing heaters) |
- |
50 |
|
15 % Discount to BIS |
| Cl.19.112 of IS:302-2-30:2007(Abnormal Operation : Ignition of bleached cotton gauge) |
- |
50 |
|
15 % Discount to BIS |
| Cl.19.114 of IS:302-2-30:2007(Abnormal Operation : the temp. of the surface of the container for oil heaters ) |
- |
50 |
|
15 % Discount to BIS |
| Cl.20 of IS:302-2-30:2007(Stability of Mechanical Hazards) |
- |
500 |
|
15 % Discount to BIS |
| Cl.21.1 of IS:302-1:2008)(Mechanical Strength : Rough handling ) |
- |
200 |
|
15 % Discount to BIS |
| Cl.21.2 of IS 302-1:2008(Mechanical Strength : Pentration by sharp implementation ) |
- |
200 |
|
15 % Discount to BIS |
| Cl.21.101 of IS:302-2-30:2007(Mechanical Strength : fire gaurd deformation test ) |
- |
100 |
|
15 % Discount to BIS |
| Cl.22.7 of IS:302-2-30:2007(Construction : Pressure test of oil heater ) |
- |
50 |
|
15 % Discount to BIS |
| Cl.22.11 of IS 302-1:2008(Construction : Fixing of non detachable parts ) |
- |
50 |
|
15 % Discount to BIS |
| Cl.22.12 of IS 302-1:2008(Construction : Fixing of Handle, knobs,grips,lever and similer parts ) |
- |
40 |
|
15 % Discount to BIS |
| Cl.22.13 of IS 302-1:2008(Construction : Position of handles ) |
- |
40 |
|
15 % Discount to BIS |
| Cl.22.14 of IS 302-1:2008(Construction : ragged and sharp edges) |
- |
40 |
|
15 % Discount to BIS |
| Cl.22.15 of IS 302-1:2008(Construction : Storage hooks for flexible cords) |
- |
40 |
|
15 % Discount to BIS |
| Cl.22.18 of IS 302-1:2008(Construction : Resistance to corrosion ) |
- |
40 |
|
15 % Discount to BIS |
| Cl.22.24 of IS:302-2-30:2007(Construction : test of bare heating element) |
- |
40 |
|
15 % Discount to BIS |
| Cl.22.101 of IS:302-2-30:2007(Construction : Prevention to contact with heating element) |
- |
40 |
|
15 % Discount to BIS |
| Cl.22.102 & Cl 22.103 of IS:302-2-30:2007(Construction : Fireguard ) |
- |
40 |
|
15 % Discount to BIS |
| Cl.22.106 of IS:302-2-30:2007(Construction : Checking of openings on the underside) |
- |
40 |
|
15 % Discount to BIS |
| Cl.22.106 of IS:302-2-30:2007(Construction : Checking of thermostats, timers or similar means for visibl glowing radiant heaters) |
- |
40 |
|
15 % Discount to BIS |
| Cl.23 of IS:302-1:2008(Internal Wiring
) |
- |
250 |
|
15 % Discount to BIS |
| Cl.23.7 of 302-1:2008(Internal Wiring : Colour of earting conductor
) |
- |
250 |
|
15 % Discount to BIS |
| Cl.24 of IS:302-2-30:2007(Component) |
- |
500 |
|
15 % Discount to BIS |
| Cl.25.1 of 302-1:2008(Supply Connection and External Flexible Cords : Means of connection ) |
- |
50 |
|
15 % Discount to BIS |
| Cl. 25.2 of IS 3021:2008(Supply Connection and External Flexible Cords ) |
- |
50 |
|
15 % Discount to BIS |
| Cl.25.5 of 302-1:2008(Supply Connection and External Flexible Cords : Type of attachments ) |
- |
50 |
|
15 % Discount to BIS |
| Cl.25.7 of IS:302-2-30:2007(Supply Connection and External Flexible Cords : Supply cords material ) |
- |
35 |
|
15 % Discount to BIS |
| Cl.25.8 of 302-1:2008(Supply Connection and External Flexible Cords : Resistance of supply wires ) |
- |
35 |
|
15 % Discount to BIS |
| Cl. 25.9 of 302-1:2008(Supply Connection and External Flexible Cords : Contact with sharp edge ) |
- |
35 |
|
15 % Discount to BIS |
| Cl.25.10 of 302-1:2008(Supply Connection and External Flexible Cords : Colour of earthing wire ) |
- |
35 |
|
15 % Discount to BIS |
| Cl. 25.12 of 302-1:2008(Supply Connection and External Flexible Cords : Moulding of cords ) |
- |
35 |
|
15 % Discount to BIS |
| Cl. 25.13 of 302-1:2008(Supply Connection and External Flexible Cords : Inlet opening of supply cords ) |
- |
35 |
|
15 % Discount to BIS |
| Cl.25.15 of IS 302-1:2008(Supply Connection and External Flexible Cords : Cord grip test - strain at terminals ) |
- |
35 |
|
15 % Discount to BIS |
| Cl.25.15 of IS 302-1:2008(Supply Connection and External Flexible Cords : Cord grip test - displacement) |
- |
35 |
|
15 % Discount to BIS |
| Cl.25.18 of 302-1:2008(Supply Connection and External Flexible Cords : Arrangement of cord anchorages ) |
- |
35 |
|
15 % Discount to BIS |
| Cl.25.20 of 302-1:2008(Supply Connection and External Flexible Cords : Additional insulation ) |
- |
35 |
|
15 % Discount to BIS |
| Cl.26 of IS 302-1:2008(Terminal for External Conductors
) |
- |
500 |
|
15 % Discount to BIS |
| Cl.27.1 of 302-1:2008(Provision for Earthing ) |
- |
250 |
|
15 % Discount to BIS |
| Cl.27.5 of 302-1:2008(Provision for Earthing : ECR) |
- |
250 |
|
15 % Discount to BIS |
| Cl.28 of 302-1:2008(Screws and Connections.) |
- |
500 |
|
15 % Discount to BIS |
| Cl.29.1 of IS:302-1:2008(Clearances, Creepage Distances and Solid Insulation : Clearance ) |
- |
250 |
|
15 % Discount to BIS |
| Cl.29.2 of IS:302-1:2008(Clearances, Creepage Distances and Solid Insulation : Creepage Distance) |
- |
250 |
|
15 % Discount to BIS |
| Cl.30.1 of IS:302-1:2008(Resistance to Heat and Fire: Resistance to heat. ) |
- |
500 |
|
15 % Discount to BIS |
| Cl.30.2 of 302-1:2008(Resistance to Heat and Fire : Resistance to fire) |
- |
500 |
|
15 % Discount to BIS |
| Cl.31 of IS:302-1:2008(Resistance to Rusting.) |
- |
500 |
|
15 % Discount to BIS |
| Cl.32 & IS:302-1:2008(Radition,Toxicity and similar Hazards.) |
- |
500 |
|
15 % Discount to BIS |
|
31 Dec, 2026 |
- - |
| 38 |
IS 302 : Part 2 : Sec 26 (2014) |
Safety of household and similar electrical appliances: Part 2 particular requirements: Sec 26 clocks (First Revision) |
Not Applicable |
45000 View breakup
Rs.45,000/-
[15% discount to BIS]
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6.0(Classification) |
- |
100 |
|
15 % Discount to BIS |
| 7(Marking and instructions) |
- |
500 |
|
15 % Discount to BIS |
| 8(Protection against live parts) |
- |
1500 |
|
15 % Discount to BIS |
| 9(STARTING OF MOTOR-OPERATED APPLIANCES) |
- |
0 |
|
15 % Discount to BIS |
| 10(POWER INPUT AND CURRENT) |
- |
2000 |
|
15 % Discount to BIS |
| 11(HEATING) |
- |
2000 |
|
15 % Discount to BIS |
| 13(LEAKAGE CURRENT AND ELECTRIC STRENGTH AT OPERATING TEMPERATURE) |
- |
2000 |
|
15 % Discount to BIS |
| 14(TRANSIENT OVERVOLTAGES) |
- |
3000 |
|
15 % Discount to BIS |
| 15(MOISTURE RESISTANCE) |
- |
5000 |
|
15 % Discount to BIS |
| 16(LEAKAGE CURRENT AND ELECTRIC STRENGTH) |
- |
2000 |
|
15 % Discount to BIS |
| 17(OVERLOAD PROTECTION OF TRANSFORMERS AND ASSOCIATED CIRCUITS) |
- |
2000 |
|
15 % Discount to BIS |
| 18(ENDURANCE) |
- |
0 |
|
15 % Discount to BIS |
| 19(ABNORMAL OPERATION) |
- |
2000 |
|
15 % Discount to BIS |
| 20(STABILITY AND MECHANICAL HAZARDS) |
- |
1500 |
|
15 % Discount to BIS |
| 21(MECHANICAL STRENGTH) |
- |
2000 |
|
15 % Discount to BIS |
| 22(CONSTRUCTION) |
- |
2000 |
|
15 % Discount to BIS |
| 23(INTERNAL WIRING) |
- |
2000 |
|
15 % Discount to BIS |
| 24(COMPONENTS) |
- |
2000 |
|
15 % Discount to BIS |
| 25(SUPPLY CONNECTION AND EXTERNAL FLEXIBLE CORDS) |
- |
2000 |
|
15 % Discount to BIS |
| 26(TERMINALS FOR EXTERNAL CONDUCTORS) |
- |
2000 |
|
15 % Discount to BIS |
| 27(PROVISION FOR EARTHING) |
- |
1000 |
|
15 % Discount to BIS |
| 28(SCREWS AND CONNECTIONS) |
- |
1000 |
|
15 % Discount to BIS |
| 29(CLEARANCES, CREEPAGE DISTANCES AND SOLID INSULATION) |
- |
2500 |
|
15 % Discount to BIS |
| 30(RESISTANCE TO HEAT AND FIRE) |
- |
3000 |
|
15 % Discount to BIS |
| 31(RESISTANCE TO RUSTING) |
- |
1000 |
|
15 % Discount to BIS |
| 32(RADIATION, TOXICITY AND SIMILAR HAZARDS) |
- |
1000 |
|
15 % Discount to BIS |
|
31 Dec, 2026 |
- Excluding: EMI / EMC ESD Simulator, Immunity simulator, CRF tester, Rs tester(Cl.19.11.4.1 to Cl.19.11.4.4). Component, Capacitor and RC units, RF Suppression X-Y capacitor, PCB Material, SMPS Transformer, Bridging resistor (Cl.24). |
| 39 |
IS 302 : Part 1 (2008) |
Safety of household and similar electrical appliances: Part 1 general requirements (Sixth Revision) |
Not Applicable |
50000 View breakup
Rs. 50,000/- For Adapters
[15% discount to BIS]
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 7(Marking and instructions) |
- |
500 |
|
15 % Discount to BIS |
| 8.1.1(Protection against live parts in all positions) |
- |
500 |
|
15 % Discount to BIS |
| 8.1.2(Protection against live parts in openings) |
- |
500 |
|
- |
| 8.1.3(Protection against live parts in visible glowing heating elements) |
- |
500 |
|
15 % Discount to BIS |
| 8.1.4(Protection against live parts against protective impedance) |
- |
500 |
|
15 % Discount to BIS |
| 9(Starting of motor operation test requirements and tests) |
- |
500 |
|
15 % Discount to BIS |
| 10.1(Power input) |
- |
1000 |
|
15 % Discount to BIS |
| 10.2(Current input) |
- |
1000 |
|
15 % Discount to BIS |
| 11.1(General) |
- |
667 |
|
15 % Discount to BIS |
| 11.2(General) |
- |
667 |
|
15 % Discount to BIS |
| 11.3(Heating) |
- |
667 |
|
15 % Discount to BIS |
| 13.1(General) |
- |
667 |
|
15 % Discount to BIS |
| 13.2(Leakage current at operating temperature) |
- |
667 |
|
15 % Discount to BIS |
| 13.3(Electric Strength at operating temperature) |
- |
667 |
|
15 % Discount to BIS |
| 14(Transient Over Voltages) |
- |
4000 |
|
15 % Discount to BIS |
| 15.0(General) |
- |
2000 |
|
15 % Discount to BIS |
| 15.1(Ingress Protection test other than IPX0 (IP test)) |
- |
2000 |
|
15 % Discount to BIS |
| 15.2(Spillage Test) |
- |
2000 |
|
15 % Discount to BIS |
| 15.3(Humidity Test) |
- |
2000 |
|
15 % Discount to BIS |
| 16.0(General) |
- |
400 |
|
15 % Discount to BIS |
| 16.1(General) |
- |
400 |
|
15 % Discount to BIS |
| 16.2(Leakage Current (after Clause 15)) |
- |
400 |
|
15 % Discount to BIS |
| 16.3(Electric Strength (after clause 15 and 16.2)) |
- |
400 |
|
15 % Discount to BIS |
| 17(Over Load Protection of Transformers and associated circuits) |
- |
2000 |
|
15 % Discount to BIS |
| 18(Endurance Test requirements and tests) |
- |
500 |
|
15 % Discount to BIS |
| 19(Abnormal Operation) |
- |
2000 |
|
15 % Discount to BIS |
| 20(Stability test) |
- |
2000 |
|
15 % Discount to BIS |
| 21(Mechanical Strength Test) |
- |
2000 |
|
15 % Discount to BIS |
| 22(Construction verification related test) |
- |
2000 |
|
15 % Discount to BIS |
| 23(General) |
- |
500 |
|
15 % Discount to BIS |
| 24(Components) |
- |
2000 |
|
15 % Discount to BIS |
| 25(Supply connection and external flexible cords) |
- |
2000 |
|
15 % Discount to BIS |
| 26(Terminals for external conductors) |
- |
2000 |
|
15 % Discount to BIS |
| 27(Provision for earthing) |
- |
1000 |
|
15 % Discount to BIS |
| 28(Screw test and connections) |
- |
1000 |
|
15 % Discount to BIS |
| 29(clearance, creepage distances and solid insulation) |
- |
2500 |
|
15 % Discount to BIS |
| 30.1(Ball pressure test) |
- |
1000 |
|
15 % Discount to BIS |
| 30.2(Glow Wire Test) |
- |
1000 |
|
15 % Discount to BIS |
| 30.2(Needle Flame Test) |
- |
1000 |
|
15 % Discount to BIS |
| 31(Resistance to Rusting) |
- |
1000 |
|
15 % Discount to BIS |
| 32(Radiation Toxicity and Similar Hazards) |
- |
1000 |
|
15 % Discount to BIS |
| 4(General requirement) |
- |
500 |
|
15 % Discount to BIS |
| 16(Leakage current and electric strength) |
- |
400 |
|
15 % Discount to BIS |
| 18(Endurance) |
- |
500 |
|
15 % Discount to BIS |
|
31 Dec, 2026 |
- For rating up to 300V,
1Φ, AC .
Excluding Components:
EMI/EMC (Cl.19.11.4.2),
Component (Cl.24)
"(1)Cooking ranges, hobs, ovens and similar appliances, (2)Commercial Dispensing Appliances and Vending Machines, (3) spin extractors
(For testing charges please refer relevant Part 2 standard in LIMS)" |
| 40 |
IS 302 : Part 2 : Sec 6 (2009) |
Safety of household and similar electrical appliances: Part 2 particular requirements: Sec 6 cooking ranges, hobs, ovens and similar appliances (First Revision) |
Not Applicable |
15000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6.0(Classification) |
- |
100 |
|
15 % Discount to BIS |
| 7.0(Marking and instructions) |
- |
900 |
|
15 % Discount to BIS |
| 8.0(Protection against access to live part test) |
- |
1000 |
|
15 % Discount to BIS |
| 9.0(Starting of motor-operated appliances test) |
- |
1000 |
|
15 % Discount to BIS |
| 10.0(Power Input and current test) |
- |
1000 |
|
15 % Discount to BIS |
| 11.0(Heating test) |
- |
2000 |
|
15 % Discount to BIS |
| 13.0(Leakage current and electric strength test) |
- |
1000 |
|
15 % Discount to BIS |
| 14.0(Transient voltages) |
- |
2000 |
|
15 % Discount to BIS |
| 15.0(Moisture Resistance) |
- |
5000 |
|
15 % Discount to BIS |
| 16.0(Leakage current and electric strength test) |
- |
1000 |
|
15 % Discount to BIS |
| 17.0(Overload protection of transformers test) |
- |
700 |
|
15 % Discount to BIS |
| 18.0(Endurance test) |
- |
300 |
|
15 % Discount to BIS |
| 19.0(Abnormal Operations) |
- |
1000 |
|
15 % Discount to BIS |
| 20.0(Stability and Mechanical Hazards) |
- |
1000 |
|
15 % Discount to BIS |
| 21.0(Mechanical Strength) |
- |
1000 |
|
15 % Discount to BIS |
| 22.0(Construction verification related tests) |
- |
1000 |
|
15 % Discount to BIS |
| 23.0(Internal wiring) |
- |
1000 |
|
15 % Discount to BIS |
| 24.0(Components) |
- |
1000 |
|
15 % Discount to BIS |
| 25.0(Supply connections and External Flexible Cords) |
- |
1000 |
|
15 % Discount to BIS |
| 26.0(Terminal for External Conductors) |
- |
1000 |
|
15 % Discount to BIS |
| 27.0(Provision for Earthing) |
- |
1000 |
|
15 % Discount to BIS |
| 28.0(Screws and connections) |
- |
1000 |
|
15 % Discount to BIS |
| 29.0(Clearances and Creepage distances and solid insulation) |
- |
1000 |
|
15 % Discount to BIS |
| 30.0(Resistance to heat and fire) |
- |
2000 |
|
15 % Discount to BIS |
| 31.0(Resistance to rusting) |
- |
1000 |
|
15 % Discount to BIS |
| 32.0(Radiation, Toxicity and Similar hazards) |
- |
700 |
|
15 % Discount to BIS |
| 15.4 (b)(Cold impact) |
- |
300 |
|
15 % Discount to BIS |
|
31 Dec, 2026 |
- Included w.e.f. 24-07-2020. |
| 41 |
IS 302 : Part 2 : Sec 25 (2014) |
Safety of household and similar electrical appliances: Part 2 Particular requirements: Section 25 Microwave ovens |
Not Applicable |
60000 View breakup
Rs.60,000/-
[15% discount to BIS]
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6.0(Classification) |
- |
100 |
|
15 % Discount to BIS |
| 7(Marking and instructions) |
- |
500 |
|
15 % Discount to BIS |
| 8(Protection against live parts) |
- |
2000 |
|
15 % Discount to BIS |
| 9(STARTING OF MOTOR-OPERATED APPLIANCES) |
- |
100 |
|
15 % Discount to BIS |
| 10(POWER INPUT AND CURRENT) |
- |
2000 |
|
15 % Discount to BIS |
| 11(HEATING) |
- |
2000 |
|
15 % Discount to BIS |
| 13(LEAKAGE CURRENT AND ELECTRIC STRENGTH AT OPERATING TEMPERATURE) |
- |
2000 |
|
15 % Discount to BIS |
| 14(IMPULSE VOLTAGE TEST) |
- |
4000 |
|
15 % Discount to BIS |
| 15(HUMIDITY TREATMENT TEST) |
- |
8000 |
|
15 % Discount to BIS |
| 16(LEAKAGE CURRENT AND ELECTRIC STRENGTH) |
- |
2000 |
|
15 % Discount to BIS |
| 17(OVERLOAD PROTECTION OF TRANSFORMERS AND ASSOCIATED CIRCUITS) |
- |
2000 |
|
15 % Discount to BIS |
| 18(ENDURANCE) |
- |
1000 |
|
15 % Discount to BIS |
| 19(ABNORMAL OPERATION) |
- |
4000 |
|
15 % Discount to BIS |
| 20(STABILITY AND MECHANICAL HAZARDS) |
- |
4000 |
|
15 % Discount to BIS |
| 21(MECHANICAL STRENGTH) |
- |
2000 |
|
15 % Discount to BIS |
| 22(CONSTRUCTION) |
- |
4000 |
|
15 % Discount to BIS |
| 23(INTERNAL WIRING) |
- |
2000 |
|
15 % Discount to BIS |
| 24(COMPONENTS) |
- |
5000 |
|
15 % Discount to BIS |
| 25(SUPPLY CONNECTION AND EXTERNAL FLEXIBLE CORDS) |
- |
2000 |
|
15 % Discount to BIS |
| 26(TERMINALS FOR EXTERNAL CONDUCTORS) |
- |
2000 |
|
15 % Discount to BIS |
| 27(PROVISION FOR EARTHING) |
- |
1000 |
|
15 % Discount to BIS |
| 28(SCREWS AND CONNECTIONS) |
- |
1000 |
|
15 % Discount to BIS |
| 29(CLEARANCES, CREEPAGE DISTANCES AND SOLID INSULATION) |
- |
2500 |
|
15 % Discount to BIS |
| 30(RESISTANCE TO HEAT AND FIRE) |
- |
4000 |
|
15 % Discount to BIS |
| 31(RESISTANCE TO RUSTING) |
- |
1000 |
|
15 % Discount to BIS |
| 32(RADIATION, TOXICITY AND SIMILAR HAZARDS) |
- |
1000 |
|
15 % Discount to BIS |
|
31 Dec, 2026 |
- Excluding: EMI / EMC ESD Simulator, Immunity simulator, CRF tester, Rs tester(Cl.19.11.4.1 to Cl.19.11.4.4), Component Magnetron, HV Transformer Capacitor Diode, Capacitor and RC units, RF Suppression X-Y capacitor, PCB Material, SMPS Transformer, Bridging resistor. Annex CC: Salt Spray Test; Salt Spray Chamber, NaCL, pH meter(Cl.24). |
| 42 |
IS 302 : Part 2 : Sec 15 (2009) |
Safety of household and similar electrical appliances: Part 2 particular requirements: Sec 15 appliances for heating liquids (First Revision) |
Not Applicable |
25000 View breakup
Rs.25,700/-
[10% Discount to BIS]
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6.0(Classification) |
- |
100 |
|
15 % Discount to BIS |
| 7(Marking and instructions) |
- |
900 |
|
15 % Discount to BIS |
| 8(Protection against live parts) |
- |
500 |
|
15 % Discount to BIS |
| 9(STARTING OF MOTOR-OPERATED APPLIANCES) |
- |
500 |
|
15 % Discount to BIS |
| 10(POWER INPUT AND CURRENT) |
- |
1000 |
|
15 % Discount to BIS |
| 11(HEATING) |
- |
2000 |
|
15 % Discount to BIS |
| 13(LEAKAGE CURRENT AND ELECTRIC STRENGTH AT OPERATING TEMPERATURE) |
- |
1000 |
|
15 % Discount to BIS |
| 14(TRANSIENT OVERVOLTAGES) |
- |
2000 |
|
15 % Discount to BIS |
| 15(MOISTURE RESISTANCE) |
- |
5000 |
|
15 % Discount to BIS |
| 16(LEAKAGE CURRENT AND ELECTRIC STRENGTH) |
- |
1000 |
|
15 % Discount to BIS |
| 17(OVERLOAD PROTECTION OF TRANSFORMERS AND ASSOCIATED CIRCUITS) |
- |
1000 |
|
15 % Discount to BIS |
| 18(ENDURANCE) |
- |
500 |
|
15 % Discount to BIS |
| 19(ABNORMAL OPERATION) |
- |
500 |
|
15 % Discount to BIS |
| 20(STABILITY AND MECHANICAL HAZARDS) |
- |
1000 |
|
15 % Discount to BIS |
| 21(MECHANICAL STRENGTH) |
- |
1000 |
|
15 % Discount to BIS |
| 22(CONSTRUCTION) |
- |
1000 |
|
15 % Discount to BIS |
| 23(INTERNAL WIRING) |
- |
1000 |
|
15 % Discount to BIS |
| 24(COMPONENTS) |
- |
1000 |
|
15 % Discount to BIS |
| 25(SUPPLY CONNECTION AND EXTERNAL FLEXIBLE CORDS) |
- |
1000 |
|
15 % Discount to BIS |
| 26(TERMINALS FOR EXTERNAL CONDUCTORS) |
- |
1000 |
|
15 % Discount to BIS |
| 27(PROVISION FOR EARTHING) |
- |
1000 |
|
15 % Discount to BIS |
| 28(SCREWS AND CONNECTIONS) |
- |
1000 |
|
15 % Discount to BIS |
| 29(CLEARANCES, CREEPAGE DISTANCES AND SOLID INSULATION) |
- |
1000 |
|
15 % Discount to BIS |
| 30(RESISTANCE TO HEAT AND FIRE) |
- |
2000 |
|
15 % Discount to BIS |
| 31(RESISTANCE TO RUSTING) |
- |
1000 |
|
15 % Discount to BIS |
| 32(RADIATION, TOXICITY AND SIMILAR HAZARDS) |
- |
300 |
|
15 % Discount to BIS |
| 15.4 (b)(Cold impact) |
- |
200 |
|
15 % Discount to BIS |
|
31 Dec, 2026 |
- Included w.e.f. 24-07-2020. |
| 43 |
IS 302 : Part 2 : Sec 14 (2009) |
Safety of household and similar electrical appliances: Part 2 particular requirements: Sec 14 electric kitchen machines (First Revision) |
Not Applicable |
30000 View breakup
Rs.14700/-[15% Discount to BIS]
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6(Classification- IS 302-1 ) |
- |
100 |
|
15 % Discount to BIS |
| 7.1(Marking- IS 302-1) |
- |
80 |
|
15 % Discount to BIS |
| 7.3(Marking- IS 302-1) |
- |
80 |
|
15 % Discount to BIS |
| 7.4(Marking- IS 302-1) |
- |
80 |
|
15 % Discount to BIS |
| 7.6(Marking- IS 302-1) |
- |
80 |
|
15 % Discount to BIS |
| 7.7(Marking- IS 302-1) |
- |
80 |
|
15 % Discount to BIS |
| 7.8(Marking- IS 302-1) |
- |
80 |
|
15 % Discount to BIS |
| 7.11(Marking- IS 302-1) |
- |
80 |
|
15 % Discount to BIS |
| 7.12(Marking- IS 302-1) |
- |
80 |
|
15 % Discount to BIS |
| 7.13(Marking- IS 302-1) |
- |
80 |
|
15 % Discount to BIS |
| 7.14(Marking- IS 302-1) |
- |
80 |
|
15 % Discount to BIS |
| 7.15(Marking- IS 302-1) |
- |
80 |
|
15 % Discount to BIS |
| 7.101(Marking) |
- |
40 |
|
15 % Discount to BIS |
| 8( Protection Against Electric Shock, IS 302-1) |
- |
900 |
|
15 % Discount to BIS |
| 10(Power Input and Current, IS 302-1) |
- |
1000 |
|
15 % Discount to BIS |
| 11(Heating, IS 302-1) |
- |
2000 |
|
15 % Discount to BIS |
| 13(Electrical Insulation and Leakage Current at Operating Temperature: Leakage current, IS 302-1) |
- |
500 |
|
15 % Discount to BIS |
| 14(Transient Over Voltages, IS 302-1) |
- |
2000 |
|
15 % Discount to BIS |
| 15(Moisture Resistance, IS 302-1) |
- |
3000 |
|
15 % Discount to BIS |
| 16(Electrical Insulation and Leakage Current at Operating Temperature: Leakage current, IS 302-1) |
- |
500 |
|
15 % Discount to BIS |
| 16(Electrical Insulation and Leakage Current at Operating Temperature: High Voltage, IS 302-1) |
- |
500 |
|
15 % Discount to BIS |
| 19.8(Abnormal Operation, IS 302-1) |
- |
200 |
|
15 % Discount to BIS |
| 19.7(Abnormal Operation, IS 302-1) |
- |
160 |
|
15 % Discount to BIS |
| 19.9(Abnormal Operation, IS 302-1) |
- |
160 |
|
15 % Discount to BIS |
| 19.1(Abnormal Operation, IS 302-1) |
- |
160 |
|
15 % Discount to BIS |
| 19.101(Abnormal Operation) |
- |
160 |
|
15 % Discount to BIS |
| 19.102(Abnormal Operation) |
- |
160 |
|
15 % Discount to BIS |
| 20.1(Stability & Mechanical Hazards, IS 302-1) |
- |
60 |
|
15 % Discount to BIS |
| 20.2(Stability & Mechanical Hazards, IS 302-1) |
- |
60 |
|
15 % Discount to BIS |
| 20.101(Stability & Mechanical Hazards) |
- |
55 |
|
15 % Discount to BIS |
| 20.102(Stability & Mechanical Hazards) |
- |
55 |
|
15 % Discount to BIS |
| 20.103(Stability & Mechanical Hazards) |
- |
55 |
|
15 % Discount to BIS |
| 20.104(Stability & Mechanical Hazards) |
- |
55 |
|
15 % Discount to BIS |
| 20.105(Stability & Mechanical Hazards) |
- |
55 |
|
15 % Discount to BIS |
| 20.106(Stability & Mechanical Hazards) |
- |
55 |
|
15 % Discount to BIS |
| 20.107(Stability & Mechanical Hazards) |
- |
55 |
|
15 % Discount to BIS |
| 20.108(Stability & Mechanical Hazards) |
- |
55 |
|
15 % Discount to BIS |
| 20.109(Stability & Mechanical Hazards) |
- |
55 |
|
15 % Discount to BIS |
| 20.110(Stability & Mechanical Hazards) |
- |
55 |
|
15 % Discount to BIS |
| 20.111(Stability & Mechanical Hazards) |
- |
55 |
|
15 % Discount to BIS |
| 20.112(Stability & Mechanical Hazards) |
- |
55 |
|
15 % Discount to BIS |
| 20.113(Stability & Mechanical Hazards) |
- |
55 |
|
15 % Discount to BIS |
| 20.114(Stability & Mechanical Hazards) |
- |
55 |
|
15 % Discount to BIS |
| 20.115(Stability & Mechanical Hazards) |
- |
55 |
|
15 % Discount to BIS |
| 20.116(Stability & Mechanical Hazards) |
- |
55 |
|
15 % Discount to BIS |
| 21.1(Mechanical Strength, IS 302-1) |
- |
500 |
|
15 % Discount to BIS |
| 21.2(Mechanical Strength, IS 302-1) |
- |
500 |
|
15 % Discount to BIS |
| 22(Construction, IS 302-1) |
- |
400 |
|
15 % Discount to BIS |
| 22.101(Construction) |
- |
300 |
|
15 % Discount to BIS |
| 22.102(Construction) |
- |
300 |
|
15 % Discount to BIS |
| 23.1(Internal Wiring, IS 302-1) |
- |
100 |
|
15 % Discount to BIS |
| 23.2(Internal Wiring, IS 302-1) |
- |
100 |
|
15 % Discount to BIS |
| 23.3(Internal Wiring, IS 302-1) |
- |
100 |
|
15 % Discount to BIS |
| 23.4(Internal Wiring, IS 302-1) |
- |
100 |
|
15 % Discount to BIS |
| 23.5(Internal Wiring, IS 302-1) |
- |
100 |
|
15 % Discount to BIS |
| 23.6(Internal Wiring, IS 302-1) |
- |
100 |
|
15 % Discount to BIS |
| 23.7(Internal Wiring, IS 302-1) |
- |
100 |
|
15 % Discount to BIS |
| 23.8(Internal Wiring, IS 302-1) |
- |
100 |
|
15 % Discount to BIS |
| 23.9(Internal Wiring, IS 302-1) |
- |
100 |
|
15 % Discount to BIS |
| 23.10(Internal Wiring, IS 302-1) |
- |
100 |
|
15 % Discount to BIS |
| 24.1(Components, IS 302-1) |
- |
250 |
|
15 % Discount to BIS |
| 24.2(Components, IS 302-1) |
- |
250 |
|
15 % Discount to BIS |
| 24.5(Components, IS 302-1) |
- |
250 |
|
15 % Discount to BIS |
| 24.6(Components, IS 302-1) |
- |
250 |
|
15 % Discount to BIS |
| 25.1(Supply Connection and External Flexible Cords, IS 302-1) |
- |
60 |
|
15 % Discount to BIS |
| 25.5(Supply Connection and External Flexible Cords, IS 302-1) |
- |
60 |
|
15 % Discount to BIS |
| 25.6(Supply Connection and External Flexible Cords, IS 302-1) |
- |
55 |
|
15 % Discount to BIS |
| 25.7(Supply Connection and External Flexible Cords, IS 302-1) |
- |
55 |
|
15 % Discount to BIS |
| 25.8(Supply Connection and External Flexible Cords, IS 302-1) |
- |
55 |
|
15 % Discount to BIS |
| 25.11(Supply Connection and External Flexible Cords, IS 302-1) |
- |
55 |
|
15 % Discount to BIS |
| 25.12(Supply Connection and External Flexible Cords, IS 302-1) |
- |
55 |
|
15 % Discount to BIS |
| 25.13(Supply Connection and External Flexible Cords, IS 302-1) |
- |
55 |
|
15 % Discount to BIS |
| 25.14(Supply Connection and External Flexible Cords, IS 302-1) |
- |
55 |
|
15 % Discount to BIS |
| 25.15(Supply Connection and External Flexible Cords, IS 302-1) |
- |
55 |
|
15 % Discount to BIS |
| 25.16(Supply Connection and External Flexible Cords, IS 302-1) |
- |
55 |
|
15 % Discount to BIS |
| 25.17(Supply Connection and External Flexible Cords, IS 302-1) |
- |
55 |
|
15 % Discount to BIS |
| 25.18(Supply Connection and External Flexible Cords, IS 302-1) |
- |
55 |
|
15 % Discount to BIS |
| 25.19(Supply Connection and External Flexible Cords, IS 302-1) |
- |
55 |
|
15 % Discount to BIS |
| 25.2(Supply Connection and External Flexible Cords, IS 302-1) |
- |
55 |
|
15 % Discount to BIS |
| 25.21(Supply Connection and External Flexible Cords, IS 302-1) |
- |
55 |
|
15 % Discount to BIS |
| 25.22(Supply Connection and External Flexible Cords, IS 302-1) |
- |
55 |
|
15 % Discount to BIS |
| 26(Terminals for External Conductors, IS 302-1) |
- |
1000 |
|
15 % Discount to BIS |
| 26.9(Supply Connection and External Flexible Cords, IS 302-1) |
- |
55 |
|
15 % Discount to BIS |
| 27(Provision for Earthing, IS 302-1) |
- |
200 |
|
15 % Discount to BIS |
| 27.2(Provision for Earthing, IS 302-1) |
- |
200 |
|
15 % Discount to BIS |
| 27.3(Provision for Earthing, IS 302-1) |
- |
200 |
|
15 % Discount to BIS |
| 27.4(Provision for Earthing, IS 302-1) |
- |
200 |
|
15 % Discount to BIS |
| 27.5(Provision for Earthing, IS 302-1) |
- |
200 |
|
15 % Discount to BIS |
| 28(Screws & Connections, IS 302-1) |
- |
1000 |
|
15 % Discount to BIS |
| 29.1(Clearances, Creepage distances and Solid Insulation, IS 302-1) |
- |
500 |
|
15 % Discount to BIS |
| 29.2(Clearances, Creepage distances and Solid Insulation, IS 302-1) |
- |
500 |
|
15 % Discount to BIS |
| 30.1(Resistance to Heat and Fire, IS 302-1) |
- |
1000 |
|
15 % Discount to BIS |
| 30.2(Resistance to Heat and Fire, IS 302-1) |
- |
1000 |
|
15 % Discount to BIS |
| 31(Resistance of Rusting, IS 302-1) |
- |
1000 |
|
15 % Discount to BIS |
| 32(Radiation, Toxicity and similar Hazard IS 302-1) |
- |
1000 |
|
15 % Discount to BIS |
| 13(Electrical Insulation and Leakage Current at Operating Temperature: High Voltage, IS 302-1) |
- |
500 |
|
15 % Discount to BIS |
| 15.1(Moisture Resistance, IS 302-1) |
- |
1000 |
|
15 % Discount to BIS |
| 15.2(Moisture Resistance, IS 302-1) |
- |
1000 |
|
15 % Discount to BIS |
| 17(Overload protection of Transformers and Associated Circuits, IS 302-1) |
- |
1000 |
|
15 % Discount to BIS |
|
31 Dec, 2026 |
- Excluding: Cl. 24 Components and Cl. 19.11.4 EMI/EMC Test. Included w.e.f. 24-07-2020. |
| 44 |
IS 302 : Part 2 : Sec 3 (2007) |
Safety of household and similar electrical appliances: Part 2 particular requirements: Sec 3 electric iron (First Revision) |
Not Applicable |
15000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6(Classification- IS 302-1 ) |
- |
100 |
|
15 % Discount to BIS |
| 7.1(Marking- IS 302-1) |
- |
60 |
|
15 % Discount to BIS |
| 7.3(Marking- IS 302-1) |
- |
40 |
|
15 % Discount to BIS |
| 7.4(Marking- IS 302-1) |
- |
40 |
|
15 % Discount to BIS |
| 7.6(Marking- IS 302-1) |
- |
40 |
|
15 % Discount to BIS |
| 7.7(Marking- IS 302-1) |
- |
40 |
|
15 % Discount to BIS |
| 7.8(Marking- IS 302-1) |
- |
40 |
|
15 % Discount to BIS |
| 7.11(Marking- IS 302-1) |
- |
40 |
|
15 % Discount to BIS |
| 7.12(Marking- IS 302-1) |
- |
40 |
|
15 % Discount to BIS |
| 7.13(Marking- IS 302-1) |
- |
40 |
|
15 % Discount to BIS |
| 7.14(Marking- IS 302-1) |
- |
40 |
|
15 % Discount to BIS |
| 7.15(Marking- IS 302-1) |
- |
40 |
|
15 % Discount to BIS |
| 7.101(Marking) |
- |
40 |
|
15 % Discount to BIS |
| 8( Protection Against Electric Shock, IS 302-1) |
- |
500 |
|
15 % Discount to BIS |
| 10(Power Input and Current, IS 302-1) |
- |
900 |
|
15 % Discount to BIS |
| 11(Heating, IS 302-1) |
- |
1000 |
|
15 % Discount to BIS |
| 13(Electrical Insulation and Leakage Current at Operating Temperature: Leakage current, IS 302-1) |
- |
750 |
|
15 % Discount to BIS |
| 13(Electrical Insulation and Leakage Current at Operating Temperature: High Voltage, IS 302-1) |
- |
750 |
|
15 % Discount to BIS |
| 14(Transient Over Voltages, IS 302-1) |
- |
500 |
|
15 % Discount to BIS |
| 15.1(Moisture Resistance, IS 302-1) |
- |
500 |
|
15 % Discount to BIS |
| 15.2(Moisture Resistance, IS 302-1) |
- |
500 |
|
15 % Discount to BIS |
| 15.3(Moisture Resistance, IS 302-1) |
- |
500 |
|
15 % Discount to BIS |
| 16(Electrical Insulation and Leakage Current at Operating Temperature: Leakage current, IS 302-1) |
- |
250 |
|
15 % Discount to BIS |
| 16(Electrical Insulation and Leakage Current at Operating Temperature: High Voltage, IS 302-1) |
- |
250 |
|
15 % Discount to BIS |
| 19.4(Abnormal Operation, IS 302-1) |
- |
100 |
|
15 % Discount to BIS |
| 19.5(Abnormal Operation, IS 302-1) |
- |
80 |
|
15 % Discount to BIS80 |
| 19.7(Abnormal Operation) |
- |
80 |
|
15 % Discount to BIS |
| 19.9(Abnormal Operation) |
- |
80 |
|
15 % Discount to BIS |
| 19.1(Abnormal Operation) |
- |
80 |
|
15 % Discount to BIS |
| 19.101(Abnormal Operation) |
- |
80 |
|
15 % Discount to BIS |
| 20.1(Stability & Mechanical Hazards, IS 302-1) |
- |
250 |
|
15 % Discount to BIS |
| 20.2(Stability & Mechanical Hazards, IS 302-1) |
- |
250 |
|
15 % Discount to BIS |
| 21.1(Mechanical Strength, IS 302-1) |
- |
200 |
|
15 % Discount to BIS |
| 21.2(Mechanical Strength, IS 302-1) |
- |
200 |
|
15 % Discount to BIS |
| 21.101(Mechanical Strength, IS 302-2-3) |
- |
100 |
|
15 % Discount to BIS |
| 22(Construction, IS 302-1) |
- |
80 |
|
15 % Discount to BIS |
| 22.101(Construction) |
- |
60 |
|
15 % Discount to BIS |
| 22.102(Construction) |
- |
60 |
|
15 % Discount to BIS |
| 22.103(Construction) |
- |
60 |
|
15 % Discount to BIS |
| 22.104(Construction) |
- |
60 |
|
15 % Discount to BIS |
| 22.105(Construction) |
- |
60 |
|
15 % Discount to BIS |
| 22.106(Construction) |
- |
60 |
|
15 % Discount to BIS |
| 22.107(Construction) |
- |
60 |
|
15 % Discount to BIS |
| 23.1(Internal Wiring, IS 302-1) |
- |
50 |
|
15 % Discount to BIS |
| 23.2(Internal Wiring, IS 302-1) |
- |
50 |
|
15 % Discount to BIS |
| 23.3(Internal Wiring, IS 302-1) |
- |
50 |
|
15 % Discount to BIS |
| 23.4(Internal Wiring, IS 302-1) |
- |
50 |
|
15 % Discount to BIS |
| 23.5(Internal Wiring, IS 302-1) |
- |
50 |
|
15 % Discount to BIS |
| 23.6(Internal Wiring, IS 302-1) |
- |
50 |
|
15 % Discount to BIS |
| 23.7(Internal Wiring, IS 302-1) |
- |
50 |
|
15 % Discount to BIS |
| 23.8(Internal Wiring, IS 302-1) |
- |
50 |
|
15 % Discount to BIS |
| 23.9(Internal Wiring, IS 302-1) |
- |
50 |
|
15 % Discount to BIS |
| 23.10(Internal Wiring, IS 302-1) |
- |
50 |
|
15 % Discount to BIS |
| 24.1(Components, IS 302-1) |
- |
100 |
|
15 % Discount to BIS |
| 24.2(Components, IS 302-1) |
- |
100 |
|
15 % Discount to BIS |
| 24.4(Components, IS 302-1) |
- |
100 |
|
15 % Discount to BIS |
| 24.5(Components, IS 302-1) |
- |
100 |
|
15 % Discount to BIS |
| 24.6(Components, IS 302-1) |
- |
100 |
|
15 % Discount to BIS |
| 25.1(Supply Connection and External Flexible Cords, IS 302-1) |
- |
50 |
|
15 % Discount to BIS |
| 25.5(Supply Connection and External Flexible Cords, IS 302-1) |
- |
50 |
|
15 % Discount to BIS |
| 25.6(Supply Connection and External Flexible Cords, IS 302-1) |
- |
25 |
|
15 % Discount to BIS |
| 25.7(Supply Connection and External Flexible Cords, IS 302-1) |
- |
25 |
|
15 % Discount to BIS |
| 25.8(Supply Connection and External Flexible Cords, IS 302-1) |
- |
25 |
|
15 % Discount to BIS |
| 26.9(Supply Connection and External Flexible Cords, IS 302-1) |
- |
25 |
|
15 % Discount to BIS |
| 25.11(Supply Connection and External Flexible Cords, IS 302-1) |
- |
25 |
|
15 % Discount to BIS |
| 25.12(Supply Connection and External Flexible Cords, IS 302-1) |
- |
25 |
|
15 % Discount to BIS |
| 25.13(Supply Connection and External Flexible Cords, IS 302-1) |
- |
25 |
|
15 % Discount to BIS |
| 25.14(Supply Connection and External Flexible Cords, IS 302-1) |
- |
25 |
|
15 % Discount to BIS |
| 25.15(Supply Connection and External Flexible Cords, IS 302-1) |
- |
25 |
|
15 % Discount to BIS |
| 25.16(Supply Connection and External Flexible Cords, IS 302-1) |
- |
25 |
|
15 % Discount to BIS |
| 25.17(Supply Connection and External Flexible Cords, IS 302-1) |
- |
25 |
|
15 % Discount to BIS |
| 25.18(Supply Connection and External Flexible Cords, IS 302-1) |
- |
25 |
|
15 % Discount to BIS |
| 25.19(Supply Connection and External Flexible Cords, IS 302-1) |
- |
25 |
|
15 % Discount to BIS |
| 25.2(Supply Connection and External Flexible Cords, IS 302-1) |
- |
25 |
|
15 % Discount to BIS |
| 25.21(Supply Connection and External Flexible Cords, IS 302-1) |
- |
25 |
|
15 % Discount to BIS |
| 25.22(Supply Connection and External Flexible Cords, IS 302-1) |
- |
25 |
|
15 % Discount to BIS |
| 26(Terminals for External Conductors, IS 302-1) |
- |
500 |
|
15 % Discount to BIS |
| 27.1(Provision for Earthing, IS 302-1) |
- |
100 |
|
15 % Discount to BIS |
| 27.2(Provision for Earthing, IS 302-1) |
- |
100 |
|
15 % Discount to BIS |
| 27.3(Provision for Earthing, IS 302-1) |
- |
100 |
|
15 % Discount to BIS |
| 27.4(Provision for Earthing, IS 302-1) |
- |
100 |
|
15 % Discount to BIS |
| 27.5(Provision for Earthing, IS 302-1) |
- |
100 |
|
15 % Discount to BIS |
| 28(Screws & Connections, IS 302-1) |
- |
500 |
|
15 % Discount to BIS |
| 29.1(Clearances, Creepage distances and Solid Insulation, IS 302-1) |
- |
250 |
|
15 % Discount to BIS |
| 29.2(Clearances, Creepage distances and Solid Insulation, IS 302-1) |
- |
250 |
|
15 % Discount to BIS |
| 30.1(Resistance to Heat, Fire & Tracking, IS 302-1) |
- |
500 |
|
15 % Discount to BIS |
| 30.2(Resistance to Heat, Fire & Tracking, IS 302-1) |
- |
500 |
|
15 % Discount to BIS |
| 31(Resistance of Rusting, IS 302-1) |
- |
500 |
|
15 % Discount to BIS |
| 32(Radiation, Toxicity and similar Hazard IS 302-1) |
- |
500 |
|
15 % Discount to BIS |
|
31 Dec, 2026 |
- - |