8971 BIS, Eastern Regional Laboratory (ERL) None IS 7904 (2018) High carbon steel wire rods - Specification (Second Revision) - - View breakup
-
- -
Except Cl.5.1 V, Nb, Ti, B, Al
8972 BIS, Eastern Regional Laboratory (ERL) None IS 1239 : Part 1 (2004) Steel Tubes, Tubulars and Other Wrought Steel Fittings : Part 1 Steel Tubes (BI-LINGUAL) For all nominal bore and class Rs. 9200/ View breakup
-
- -
Facility not available for Al,B,Nb,V,Ti,Ca, Hydrostatic test and thread gauges Sample required- 1m x1 No + 1.8 m pc for bend test up to 50 mm NB + 50 g drilling + 4 pcsx10 cm
8973 BIS, Eastern Regional Laboratory (ERL) None IS 8931 (1993) copper alloy fancy single taps, combination tap assembly and stop valves for water services - Rs 3600/ View breakup
-
- -
Except critical dimension and performance requirement
8974 BIS, Eastern Regional Laboratory (ERL) None IS 733 (1983) Specification for wrought aluminium and aluminium alloy bars, rods and sections (For General Engineering Purposes) (Third Revision) For all grades except for the tests mentioned in remarks - View breakup
-
- -
Except Aluminium, Vanadium
8975 Central Power Research Institute (CPRI), Bangalore 6101024 IS 16227 : Part 2 (2016) Instrument transformers: Part 2 additional requirements for current transformers - 250000 View breakup
-
31 Dec, 2026 -
-
8976 BIS, Eastern Regional Laboratory (ERL) None IS 319 (2007) Free cutting brass bars, rods and section - Specification (Fifth Revision) - - View breakup
-
- -
Excluding Cl.4.3.1 S, C(<0.05%), Mo(>1.5%)
8977 Central Power Research Institute (CPRI), Bangalore 6101024 IS/IEC 60898 : PART 1 (2015) Electrical accessories - Circuit - Breakers for overcurrent protection for household and similar installations: Part 1 circuit - Breakers for a.c. operation (First Revision) - 1022650 View breakup
Test charges for all sequences combined Rs. 750620/-, Rs. 886600/-, Rs. 1076710/-, Rs. 1176070/- for 1, 2, 3, 4 poles respectively; Test Sequence (A1+ A2): Test sequence A1 Rs. 14260/-, Rs. 17200/-, Rs. 20140/-, Rs. 23080/- for 1, 2, 3, 4 poles respectively; for A2 Rs. 5980/-; Test Sequence B: Rs. 253820/-, Rs. 273830/-, Rs. 296930/-, Rs. 334730/- for 1, 2, 3, 4 poles respectively; Test Sequence C Test Sequence C1 : Rs. 161130/-, Rs. 172680/-, Rs. 237210/-, Rs. 251850/- for 1, 2, 3, 4 poles respectively; Test Sequence C2 : Rs. 63480/-, Rs. 72300/-, Rs. 124890/-, Rs. 133710/- for 1, 2, 3, 4 poles respectively; Test Sequence D (D0 + D1): Test sequence D0 Rs. 61540/-, Rs. 61540/-, Rs. 61540/-, Rs. 61540/- for 1, 2, 3, 4 poles respectively; Test sequence D1 Rs. 63480/-, Rs. 79200/-, Rs. 84030/-, Rs. 92820/- for 1, 2, 3, 4 poles respectively; Test Sequence E Test Sequence E1: Rs. 63480/-, Rs. 72300/-, Rs. 84030/-, Rs. 92820 for 1, 2, 3, 4 poles respectively; Test Sequence E2: Rs. 63480/-, Rs. 79200/-, Rs. 84030/-, Rs. 92820/- for 1, 2, 3, 4 poles respectively; Test Sequence E3: Rs. 63480/-, Rs. 79200/-, Rs. 84030/-, Rs. 92820/- for 1, 2, 3, 4 poles respectively; Test charges will vary depending on the rating of the sample. The applicable test charges will be intimated through a proforma invoice.
31 Dec, 2026 -
-
8978 BIS, Southern Regional Laboratory (SRL) None IS 318 (1981) Specification for leaded tin bronze ingots and castings (Second Revision) - - View breakup
Rs 1650/- For Castings: Gr LTB1, LTB2, LTB3, LTB5
- -
3 bars Excluding except chemical tests , tensile test
8979 BIS, Southern Regional Laboratory (SRL) None IS 617 (1994) Cast aluminium and its alloys - Ingots and castings for general engineering purposes - Specification (Third Revision) - - View breakup
-
- -
" 300 mm long x 2 Nos. Facility for preparation of test specimen not available" Excluding Chemical facility not available
8980 BIS, Eastern Regional Laboratory (ERL) None IS 4432 (1988) Specification for case hardening steels (First Revision) For all grades except test mentioned in remarks - View breakup
Rs 11660/- excluding Grain size, Cleanliness of steel and additional tests For elements other than Table-1: Rs 1004/- per element
- -
Chem- Except Vanadium
8981 BIS, Western Regional Laboratory (WRL) None IS 15644 (2006) Safety of electric toys - - View breakup
-
- -
The following test facilities for clauses are not available: 1. Component (Clause 16) 2. Clause 14.15 3. Clause 20
8982 BIS, Western Regional Laboratory (WRL) None IS 5950 (1984) Specification for shot firing cables (For Use Other Than In Shafts) (First Revision) - Rs 11030/- View breakup
-
- -
-
8983 BIS, Western Regional Laboratory (WRL) None IS 11217 (1984) Specification for ultramarine blue for use in textile industry - Rs. 600 View breakup
-
- -
-
8984 BIS, Western Regional Laboratory (WRL) None IS 10124 : Part 13 (2009) Fabricated PVC-U Fittings for Potable Water Supplies - Specification Part 13 Specific Requirements for 11¼oBends PART 12 SPECIFIC REQUIREMENTS FOR 22 ½o BENDS - - View breakup
-
- -
The following test facilities are not available: (1)Effect on water (2) Testing facility above 250 mm for Short Term Hydrostatic test
8985 BIS, Western Regional Laboratory (WRL) None IS 10124 : Part 12 (2009) Fabricated pvc - U fittings for potable water supplies - Specification: Part 12 specific requirements for 22&frac12; degree bends (Second Revision) - - View breakup
-
- -
The following test facilities are not available: (1)Effect on water (2) Testing facility above 250 mm for Short Term Hydrostatic test
8986 BIS, Western Regional Laboratory (WRL) None IS 10124 : Part 11 (2009) Fabricated pvc - U fittings for potable water supplies - Specification: Part 11 specific requirements for 40 degree bends (Second Revision) - - View breakup
-
- -
The following test facilities are not available: (1)Effect on water (2) Testing facility above 250 mm for Short Term Hydrostatic test
8987 BIS, Western Regional Laboratory (WRL) None IS 10124 : Part 10 (2009) Fabricated pvc - U fittings for potable water supplies - Specification: Part 10 specific requirements for 45 degree bends (Second Revision) - - View breakup
-
- -
The following test facilities are not available: (1)Effect on water (2) Testing facility above 250 mm for Short Term Hydrostatic test
8988 BIS, Western Regional Laboratory (WRL) None IS 10124 : Part 9 (2009) Fabricated pvc - U fittings for potable water supplies - Specification: Part 9 specific requirements for 60 degree bends (Second Revision) - - View breakup
-
- -
The following test facilities are not available: (1)Effect on water (2) Testing facility above 250 mm for Short Term Hydrostatic test
8989 BIS, Western Regional Laboratory (WRL) None IS 10124 : Part 8 (2009) Fabricated pvc - U fittings for potable water supplies - Specification: Part 8 specific requirements for 90 degree bends (Second Revision) - - View breakup
-
- -
The following test facilities are not available: (1)Effect on water (2) Testing facility above 250 mm for Short Term Hydrostatic test
8990 BIS, Western Regional Laboratory (WRL) None IS 10124 : Part 7 (2009) Fabricated pvc - U fittings for potable water supplies - Specification: Part 7 specific requirements for threaded adaptors (Second Revision) - - View breakup
-
- -
The following test facilities are not available: (1)Effect on water (2) Testing facility above 250 mm for Short Term Hydrostatic test
8991 BIS, Western Regional Laboratory (WRL) None IS 10124 : Part 6 (2009) Fabricated pvc - U fittings for potable water supplies - Specification: Part 6 specific requirements for flanged tail pieces with metallic flanges (Second Revision) - - View breakup
-
- -
The following test facilities are not available: (1)Effect on water (2) Testing facility above 250 mm for Short Term Hydrostatic test
8992 BIS, Western Regional Laboratory (WRL) None IS 10124 : Part 5 (2009) Fabricated pvc - U fittings for potable water supplies - Specification: Part 5 specific requirements for equal tees (Second Revision) - - View breakup
-
- -
The following test facilities are not available: (1)Effect on water (2) Testing facility above 250 mm for Short Term Hydrostatic test
8993 BIS, Western Regional Laboratory (WRL) None IS 10124 : Part 4 (2009) Fabricated pvc - U fittings for potable water supplies - Specification: Part 4 specific requirements for caps (Second Revision) - - View breakup
-
- -
The following test facilities are not available: (1)Effect on water (2) Testing facility above 250 mm for Short Term Hydrostatic test
8994 BIS, Western Regional Laboratory (WRL) None IS 10124 : Part 3 (2009) Fabricated PVC-U Fittings for Potable Water Supplies - Specification Part 3 Specific Requirements for Straight Reducers - - View breakup
-
- -
Test facilities are not available for the following: (1)Effect on water (2) Testing facility above 250 mm for Short Term Hydrostatic test
8995 BIS, Western Regional Laboratory (WRL) None IS 5158 (1987) Specification for phthalic anhydride,technical - (Second Revision) - - View breakup
-
- -
-
8996 BIS, Western Regional Laboratory (WRL) None IS 4199 (2001) Toilet soap, liquid - Specification (Third Revision) - Rs 2980/- View breakup
-
- -
Test facility not available for following; 1.SKIN SENSITIZATION TEST ON GUINEA PIGS
8997 BIS, Western Regional Laboratory (WRL) None IS 252 (2013) Caustic soda - Specification (Fourth Revision) - Rs 5100/- (for Lye & Solid) View breakup
-
- -
Test facility not available for the following: 1. Mercury
8998 BIS, Western Regional Laboratory (WRL) None IS 21 (1992) Wrought aluminium and aluminium alloys for manufacture of utensils specification (Fourth Revision) - Rs.6600/- View breakup
-
- -
Test facilities are not available for the following: 1. Chemical composition as per Cl. 4.2 2.Tensile Test (Proof Stress ) 3.Bend Test
8999 BIS, Northern Regional Laboratory (NRL) None IS 2791 (1992) Soluble coffee powder - Specification (Third Revision) - - View breakup
Rs. 4126/- excluding copper content and pesticide residues
- -
Caffeine content, Cu
9000 BIS, Bengaluru Branch Laboratory (BNBL) None IS 6613 (2002) Neutral spirit for alcoholic drinks - Specification (First Revision) - - View breakup
-
- -
Exclusion Ethanol content ,Methyl alcohol, Higher alcohols,Lead,Acidity as Acetic acid,Ester,Furfural