Search by IS Number
Reset
15634 Results
S.No. Lab Name Osl Code Indian Standard No. Product Grade / Type / Size / Designation etc. Testing Charges (Excl. Of Taxes) Validity Date Remark
15331 BIS, Northern Regional Laboratory (NRL) None IS 1825 (1983) Specification for aluminium alloy milk cans (Second Revision) - Rs 4800.00 View breakup
-
- -
Test facility is complete,
15332 BIS, Eastern Regional Laboratory (ERL) None IS 15911 (2010) Structural steel (Ordinary Quality) - Specification All grades Rs 6750/- For elements other than Table-1: Rs 1004/- pe View breakup
-
- -
Grade designation to be declared. Type of killed material to be indicated. Requirement for testing of Nitrogen and Copper to be indicated.
15333 BIS, Northern Regional Laboratory (NRL) None IS 4224 (1972) Specification for steel wire for staples, pins and clips (First Revision) - 525 View breakup
-
- -
Test facility is complete
15334 BIS, Western Regional Laboratory (WRL) None IS 7098 : Part 1 (1988) Specification for crosslinked polyethylene insulated pvc sheathed cables: Part 1 for working voltages up to and including 1100 volts (First Revision) Except C1 & C2 category. 26250 View breakup
-
- -
Test facility not available for tests as per Clause 15.1.1 of C1 and C2 category
15335 BIS, Western Regional Laboratory (WRL) None IS 4250 (1980) Specification for domestic electric food - Mixers (Liquidizers And Grinders) (First Revision) - Rs. 32600/- View breakup
-
- -
The following test facilities are not available: 1. Cl.14 Transient Overvoltage test (as per IS 302-1) 2. Cl.19.11 and 19.12 Abnormal Operation test (as perIS 302-1) (for electronic circuit) 3. Cl 24 component test as per IS302-1
15336 BIS, Western Regional Laboratory (WRL) None IS 3975 (1999) Low carbon galvanized steel wires, formed wires and tapes for armouring of cables - Specification (Third Revision) - Rs 2700/- View breakup
-
- -
Test facility not available for the following: 1) Dimension radius R of formed wire.
15337 BIS, Central Laboratory (CL) None IS 12176 (1987) Specification for sweetened ultra high temperature (UHT) treated condensed milk - - View breakup
-
- -
-Animal House; Excluding -MEASUREMENT OF SIZE AND COUNT OF LACTOSE CRYSTALS, Cl. 4.1.10.1;
15338 BIS, Western Regional Laboratory (WRL) None IS 2465 (1984) Specification for cables for motor vehicles (Second Revision) Complete test facility for PVC Insulated General Wiring Single core PVC Insulated Unsheathed: Rs. 11030/- View breakup
-
- -
The following test facilities for ignition cables are not available: Cl 16 Capacitance, Cl 17 Ozone resistance, Cl 18 Effect of heat on flexibility, Cl 19 Effect of Oil test
15339 BIS, Western Regional Laboratory (WRL) None IS 1293 (2019) Plugs and socket - Outlets of rated Voltage up to and including 250 Volts and rated current up to and including 16 amperes - Specification (Third Revision) UP TO 16A, 250V - View breakup
-
- -
Complete Test facility available
15340 BIS, Central Laboratory (CL) None IS 8183 (1993) Bonded mineral wool - Specification (First Revision) - - View breakup
-
- -
-
15341 BIS, Western Regional Laboratory (WRL) None IS 398 : Part 5 (1992) Aluminium conductor for overhead transmission purposes - Specification: Part 5 aluminium conductors - Galvanized steel - Reinforced for extra high voltage (400 KV And Above) (First Revision) Except Test facility for clause 13.10, 13.11 and 13.12 11400 View breakup
-
- -
Test facility not available: 1. Breaking Load Test on Complete Conductor, 2. Surface conditioning test apparatus 3. Corona Test 4. Radio Interference Voltage Test.
15342 BIS, Western Regional Laboratory (WRL) None IS 398 : Part 4 (1994) Aluminium conductors for overhead transmission purposes: Part 4 aluminium alloy stranded conductors (Aluminium - Magnesium - Silicon Type) - Specification (Third Revision) - Please see remarks View breakup
-
- -
Complete Test facility available
15343 BIS, Western Regional Laboratory (WRL) None IS 398 : Part 1 (1996) Aluminium conductors for overhead transmission purposes - Specification: Part 1 aluminium stranded conductors (Third Revision) - Rs.1600/- for 7 strands, Rs.3750/- for 19 strands View breakup
-
- -
Complete Test Facility
15344 BIS, Northern Regional Laboratory (NRL) None IS 651 (2007) Glazed stoneware pipes and fittings - Specification (Sixth Revision) - Rs. 6850/- View breakup
-
- -
Chemical- complete; Mechanical- complete except HST and compression test for sizes above 300 mm
15345 BIS, Northern Regional Laboratory (NRL) None IS 458 (2003) Precast concrete pipes(With And Without Reinforcement) - Specification (Fourth Revision) - 4200/- View breakup
-
- -
Standard has been revised as IS 458 : 2021 Except three edge load and HST, Split tesnsile and compressive strength upto 1000KN load-
15346 BIS, Central Laboratory (CL) None IS 2404 (1993) Malt extract - Specification (Second Revision) - Rs 6600/- View breakup
-
- -
-
15347 BIS, Western Regional Laboratory (WRL) None IS 371 (1999) Ceiling roses - Specification (Third Revision) 6A, 250V Rs 5700/- View breakup
-
- -
-
15348 BIS, Central Laboratory (CL) None IS 5405 (2019) Sanitary napkins – Specification (second revision) - - View breakup
-
- -
-
15349 BIS, Northern Regional Laboratory (NRL) None IS 624 (2003) Bicycles - Rims - Specification (Fourth Revision) - 2850 View breakup
-
- -
Except dimensions clause 3.2 & 3.2.1 Circumference, finish test facility only for Ni/Cr coating thickness
15350 BIS, Western Regional Laboratory (WRL) None IS 204 : Part 1 (1991) Tower bolts - Specification: Part 1 ferrous metals (Fifth Revision) - Rs.2100.00. View breakup
-
- -
Test facilities are not available for the following: (1) Finish
15351 BIS, Northern Regional Laboratory (NRL) None IS 1785 : Part 2 (1983) Specification for plain hard drawn steel wire for prestressed concrete: Part 2 as - Drawn wire (First Revision) - Rs 3000/- View breakup
-
- -
Test facility is complete for Chemical Except Proof Stress
15352 BIS, Central Laboratory (CL) None IS 1251 (1988) Specification for zinc phosphide, technical Technical Rs.2300.00 View breakup
-
- -
-
15353 BIS, Central Laboratory (CL) None IS 261 (1982) Specification for copper sulphate (Second Revision) - - View breakup
-
- -
Facility is complete for this IS; Excluding NA
15354 BIS, Northern Regional Laboratory (NRL) None IS 1729 (2002) Cast iron/ductile iron drainage pipes and pipe fittings for over ground non-pressure pipeline socket and spigot series (Second Revision) - Rs. 2850/- and testing charges as per referred Iss View breakup
-
- -
Test facility is complete and Standard has been revised as IS 1729 : 2023 Facility for chemical testing is not available
15355 BIS, Northern Regional Laboratory (NRL) None IS 1489 : Part 2 (2015) Portland - Pozzolana cement - Specification: Part 2 calcined clay based - Rs.8420/- View breakup
-
- -
Test facility is complete for Chemical Except Transverse Strength Test
15356 BIS, Northern Regional Laboratory (NRL) None IS 2255 (1977) Specification for mild steel wire rod for the manufacture of machine screws (By Cold Heading Process) (Second Revision) - Rs. 600/- View breakup
-
- -
Test facility is complete for Chemical,Tensile test,Microaalloying Element
15357 BIS, Northern Regional Laboratory (NRL) None IS 2266 (2024) STEEL WIRE ROPES FOR GENERAL ENGINEERING PURPOSE - SPECIFICATION (Sixth Revision) - - View breakup
-
- -
Special Tensile Testing machine of more than 1000kN capacity is required Except "Tensile test". Test Facility is not available for clause 8.1 and test facility available only for chemical composition (except Microalloying Elements) and galvanizing for clause 8.2 as per IS 6594.
15358 BIS, Central Laboratory (CL) None IS 1806 (2018) Malted milk foods - Specification (Second Revision) - - View breakup
-
- -
-
15359 BIS, Northern Regional Laboratory (NRL) None IS 2141 (2000) Hot dip galvanized stay strand - Specification (Fourth Revision) - Rs7935/- View breakup
-
- -
Chemical - complete Mechanical Complete except except Tensile test
15360 BIS, Central Laboratory (CL) None IS 10758 (1983) Specification for de - Odourizing - Cum - Disinfectant fluids - Rs.6000/- View breakup
-
- -
-

Designed, Developed and Maintained by:

Arohatech IT Services (P) Ltd.

Contact for any query/support: supportlims@bis.gov.in