Search by IS Number
Reset
15600 Results
S.No. Lab Name Osl Code Indian Standard No. Product Grade / Type / Size / Designation etc. Testing Charges (Excl. Of Taxes) Validity Date Remark
15571 BIS, Eastern Regional Laboratory (ERL) None IS 1554 : Part 1 (1988) Specification for pvc insulated (Heavy Duty) electric cables: Part 1 for working voltages up to and including 1100 v (Third Revision) Complete for Cat 01(up to 400sq.mm)Except optional test Rs 26700 View breakup
-
- -
For Category-01 and upto 400 sq mm: all tests are available except additional tests. For cat. C1 and C2 : Except oxygen Index,Temperature index, Flame Retardance, Smoke Density,
15572 BIS, Guwahati Branch Laboratory (GBL) None IS 269 (2015) Ordinary portland cement - Specification (Sixth Revision) - - View breakup
-
- -
Qty. required (8+1) kg Except Transverse strength test (optional). Retain as partial.
15573 BIS, Western Regional Laboratory (WRL) None IS 694 (2010) Polyvinyl chloride insulated unsheathed and sheathed cables/cords with rigid and flexible conductor for rated voltages up to and including 450/750 v (Fourth Revision) - Please see remarks View breakup
-
- -
Test facility not available for Copper purity test and FR/FRLSH category cables
15574 BIS, Southern Regional Laboratory (SRL) None IS 694 (2010) Polyvinyl chloride insulated unsheathed and sheathed cables/cords with rigid and flexible conductor for rated voltages up to and including 450/750 v (Fourth Revision) PVC Cables except FR & FRLSH Category Please see remarks View breakup
-
- -
" 30 m Excluding Except FR & FRLSH test, Cu Purity test
15575 BIS, Guwahati Branch Laboratory (GBL) None IS 455 (2015) Portland slag cement - Specification - - View breakup
-
- -
Qty. required (8+1) kg Except Transverse Strength Test (Optional). Retain as partial
15576 BIS, Western Regional Laboratory (WRL) None IS 1554 : Part 1 (1988) Specification for pvc insulated (Heavy Duty) electric cables: Part 1 for working voltages up to and including 1100 v (Third Revision) - Rs 26700 View breakup
-
- -
Test facility not available for tests as per Cl. 15.1.1 of C1 and C2 category
15577 BIS, Guwahati Branch Laboratory (GBL) None IS 1489 (Part 1) (2015) Portland pozzolana cement - Specification: Part 1 fly Ash Based - Rs 8420/ View breakup
-
- -
Qty. required (8+1) kg Except Transverse Strength Test (Optional), Retain as partial
15578 BIS, Western Regional Laboratory (WRL) None IS 13334 : Part 1 (2014) Skimmed milk powder - Specification: Part 1 standard grade (Second Revision) - 10430/- View breakup
-
- -
(1) As per Cl. 5.7 The pesticide residues, heavy metals, toxins (aflatoxins and other naturally occurring toxins) and contaminants, if any, in the product shall not exceed the limits as prescribed in the Food Safety and Standards (Contaminants, Toxins and Residues) Regulations, 2011.’
15579 BIS, Bengaluru Branch Laboratory (BNBL) None IS 455 (2015) Portland slag cement - Specification - - View breakup
-
- -
Expect(Cl 7(v) Transverse Strength)
15580 BIS, Western Regional Laboratory (WRL) None IS 2124 (2000) Sodium bicarbonate - Specification (Second Revision) - Rs 4660/- for Pure Grade View breakup
Rs 8210/- for Analytical Reagent Grade Rs 4360/- for Refined Grade
- -
-
15581 BIS, Western Regional Laboratory (WRL) None IS 4984 (2016) Polyethylene pipes for water supply - Specification (Fifth Revision) - - View breakup
-
- -
The following test facilities are not available: (1) Internal Pressure creep rupture test (2)Tensile Strength for Butt-fusion (Clause 8.8) (3) Slow Crack Growth rate test (Clause 8.10) (4) Depth of strip (Clause 6.2.1) (5) Carbon Black content ( Clause 8.3) (6) For Size above 250 mm
15582 BIS, Guwahati Branch Laboratory (GBL) None IS 2062 (2011) Hot rolled medium and high tensile structural steel - Specification (Seventh Revision) - 3200 View breakup
-
- -
Qty. required Mech - Three pieces of One metre each Chem - 50 gm or 5 pcs of 50 mm i) Except Impact Test, Y-Groove crackability tests (for Gr 250C). ii) Tensile test & Bend test upto Nominal Diameter 20 mm. iii) To be completed
15583 BIS, Guwahati Branch Laboratory (GBL) None IS 1659 (2004) Block boards - Specification (Fourth Revision) MR/BWP - View breakup
-
- -
Qty. required 1 No. Test facility available for thickness upto 30 mm, Retain as partial
15584 BIS, Patna Branch Laboratory (PBL) None IS 2062 (2011) Hot rolled medium and high tensile structural steel - Specification (Seventh Revision) - 3200 View breakup
-
- -
All test facilities are available as per the IS except- i) Bend Test for thickness above 25 mm (Clause 11) ii. Tests for microalloying elements and Cr, Mo, Ni, Cu Al and B (Clause 8.2) ii) ii. Impact Test (Clause 12) FACILTY IS OUT OF ORDER
15585 BIS, Patna Branch Laboratory (PBL) None IS 1786 (2008) High strength deformed steel bars and wires for concretere inforcement - Specification (Fourth Revision) - 25780 View breakup
-
- -
"Except Pull Out Test (Mechanical Test)
15586 BIS, Patna Branch Laboratory (PBL) None IS 1489 (Part 1) (2015) Portland pozzolana cement - Specification: Part 1 fly Ash Based - - View breakup
-
- -
Except Transverse Strength (Mechanical Test) (It is an optional test as mentioned in the IS and not required for GoL.)
15587 BIS, Patna Branch Laboratory (PBL) None IS 1659 (2004) Block boards - Specification (Fourth Revision) - - View breakup
-
- -
All test facilities are available as per the IS
15588 BIS, Patna Branch Laboratory (PBL) None IS 269 (2015) Ordinary portland cement - Specification (Sixth Revision) - - View breakup
-
- -
Except Transverse Strength (Mechanical Test) (It is an optional test as mentioned in the IS and not required for GoL.)
15589 BIS, Patna Branch Laboratory (PBL) None IS 455 (2015) Portland slag cement - Specification - - View breakup
-
- -
Except Transverse Strength (Mechanical Test) (It is an optional test as mentioned in the IS and not required for GoL.)
15590 BIS, Patna Branch Laboratory (PBL) None IS 12818 (2010) Unplasticized polyvinyl chloride (Pvc - U) screen and casing pipes for bore/tubewells - Specification (Second Revision) - Rs.6450.00 View breakup
-
- -
Complete except effect on Water.
15591 BIS, Eastern Regional Laboratory (ERL) None IS 455 (2015) Portland slag cement - Specification - - View breakup
-
- -
Mech-Facility not available for transverse strength test( optional); Chem-Declaration for chloride regarding end use of cement required as per Table 1, Confirmation for testing Alkali Content required.
15592 BIS, Eastern Regional Laboratory (ERL) None IS 4984 (2016) Polyethylene pipes for water supply - Specification (Fifth Revision) All varieties - View breakup
-
- -
Mech- Except Hydraulic test, Slow Crack Growth Rate and Internal Pressure Creep Rupture test. Fused pipes required to be provided for T/S of butt fusion joints. Prepared test pieces required for density. Chem- Complete
15593 BIS, Eastern Regional Laboratory (ERL) None IS 1489 (Part 1) (2015) Portland pozzolana cement - Specification: Part 1 fly Ash Based - - View breakup
-
- -
Mech- Facility not available for transverse strength test( optional); Chem-Declaration for chloride regarding end use of cement (as per Table 1) and declaration of fly ash content & Confirmation for testing Alkali Content required.
15594 BIS, Eastern Regional Laboratory (ERL) None IS 694 (2010) Polyvinyl chloride insulated unsheathed and sheathed cables/cords with rigid and flexible conductor for rated voltages up to and including 450/750 v (Fourth Revision) Complete for Category 01- up to & including 400 sq mm Please see remarks View breakup
-
- -
Chem- Facility available for Cu purity only,Gr to be declared. Elect- Cat -01, 02 (Facility not available for- Loss of mass above 1.2 mm, Tensile & Elongation above 2.0 mm thickness.) Cat- FR, FR-LSH-( Facility not available for- oxygen index, temp. index test, Smoke Density Tests). Chem- Facility available for Cu purity only,Grade/class to be declared
15595 BIS, Central Laboratory (CL) None IS 13334 : Part 1 (2014) Skimmed milk powder - Specification: Part 1 standard grade (Second Revision) - 10430/- View breakup
-
- -
500 gm x 3
15596 BIS, Western Regional Laboratory (WRL) None IS 1786 (2008) High strength deformed steel bars and wires for concretere inforcement - Specification (Fourth Revision) - 25780 View breakup
-
- -
Test facilities are not available for the following: (1) Total elongation at maximum force, (2) Pull out test (Type test) (3) Sizes above 25 mm, (4) Micro-alloy/low alloys, Nb, V, B and Ti, Cr, Cu, Ni, Mo, Nirogen and nitrogen binding elements, like Nb, V, Ti, Al
15597 BIS, Bengaluru Branch Laboratory (BNBL) None IS 1489 (Part 1) (2015) Portland pozzolana cement - Specification: Part 1 fly Ash Based - - View breakup
-
- -
Expect (Cl 7(v) Transverse Strength)
15598 BIS, Bengaluru Branch Laboratory (BNBL) None IS 269 (2015) Ordinary portland cement - Specification (Sixth Revision) 33 GR 43GR 53 GR - View breakup
-
- -
Expect (Cl 7(v) Transverse Strength)
15599 BIS, Central Laboratory (CL) None IS 303 (2024) Plywood for General Purposes — Specification (Fourth Revision) - - View breakup
-
- -
Excluding- Steady State Formaldehyde Emission Test (Cl. 11.7)
15600 BIS, Guwahati Branch Laboratory (GBL) None IS 1786 (2008) High strength deformed steel bars and wires for concretere inforcement - Specification (Fourth Revision) Up to nominal dia of 25 mm 25780 View breakup
-
- -
Qty. required Mech -3 Pcs of 1 meter, Chem- 5 pcs* 50 mm i) Tensile Strength, Yield Stress, Elongation percentage, Bend/Rebend- Test facility available upto Nominal Diameter 20 mm. ii) Except Pull-out test. iii) Retain as partial

Designed, Developed and Maintained by:

Arohatech IT Services (P) Ltd.