BIS, Western Regional Laboratory (WRL)

BUREAU OF INDIAN STANDARDS (WESTERN REGIONAL LABORATORY), PLOT NO. E9, ROAD NO. 8, M.I.D.C, ANDHERI (EAST), MUMBAI, MAHARASHTRA, INDIA, MUMBAI, Mumbai Suburban, Maharashtra, 400093
- wrol@bis.gov.in
Scope List
Reset
282 Results
S.No. Indian Standard No. Product Grade / Type / Size / Designation etc. Exclusion Testing Charges (Excl. Of Taxes) Facility Type Effective Date Validity Date Remark
271 IS 12818 (2010) Unplasticized polyvinyl chloride (Pvc - U) screen and casing pipes for bore/tubewells - Specification (Second Revision) - - - View breakup
-
Partial - Remark 1: For measurement of the shore hardness of the sealing ring prepared button piece is required. Remark 2 : The following test facilities are not available: (1) For Outside Diameter above 250 mm, (2) Effect on water (3)Resistance to external blow
272 IS 398 : Part 2 (1996) Aluminium conductors for overhead transmission purposes - Specification: Part 2 aluminium conuuctors, galvanized steel - Reinforced (Third Revision) Up to 100 sq mm - - View breakup
-
Partial - Test facility not available for Cl. 13.9, 13.10 and 13.11 for size 100 sq.mm and above.
273 IS 3854 (1997) Switches for domestic and similar purposes - Specification (Second Revision) - - - View breakup
-
Partial - Complete TF is available for variety upto and including 20A. For above 20A rating (32A, 63A), the following facilities are not available: 1. Cl 17 Temperature rise 2. Cl 18, Making and breaking Capacity 3. Cl 19 Normal Operation"
274 IS 694 (2010) Polyvinyl chloride insulated unsheathed and sheathed cables/cords with rigid and flexible conductor for rated voltages up to and including 450/750 v (Fourth Revision) - - - View breakup
-
Partial - Test facility not available for Copper purity test and FR/FRLSH category cables
275 IS 1554 : Part 1 (1988) Specification for pvc insulated (Heavy Duty) electric cables: Part 1 for working voltages up to and including 1100 v (Third Revision) - - - View breakup
-
Partial - Test facility not available for tests as per Cl. 15.1.1 of C1 and C2 category
276 IS 13334 : Part 1 (2014) Skimmed milk powder - Specification: Part 1 standard grade (Second Revision) - - - View breakup
-
Partial - (1) As per Cl. 5.7 The pesticide residues, heavy metals, toxins (aflatoxins and other naturally occurring toxins) and contaminants, if any, in the product shall not exceed the limits as prescribed in the Food Safety and Standards (Contaminants, Toxins and Residues) Regulations, 2011.’
277 IS 2347 (2017) Domestic pressure cooker - Specification (Sixth Revision) - - - View breakup
-
Partial - The following test facilities are not available: (1) Material as per Clause 5.1, 5.2, 5.5, 5.6, 5.7, 5.8, 5.9, 5.10, 5.11 (2) Test for Hard Anodized Surface. (3) Test for spring-loaded mechanism (4) Test for handle and knob. (5) Electrical Pressure cooker
278 IS 2124 (2000) Sodium bicarbonate - Specification (Second Revision) - - - View breakup
-
Complete - -
279 IS 14151 : Part 2 (2008) Irrigation equipment - Sprinkler pipes - Specification: Part 2 quick coupled polyethylene pipes and fittings (Second Revision) - - - View breakup
-
Partial - The following test facilities are not available: (1) Weldability Test
280 IS 4984 (2016) Polyethylene pipes for water supply - Specification (Fifth Revision) - - - View breakup
-
Partial - The following test facilities are not available: (1)Internal Pressure creep rupture test (2)Tensile Strength for Butt-fusion (Clause 8.8) (3) Elongation at break (Clause 8.9) (4) Slow Crack Growth rate test (Clause 8.10) (5) Density (Clause 8.7) (6) Depth of strip (Clause 6.2.1) (7) Oxidation Induction Time (Clause 8.5) (8) Overall Migration (Clause 8.6) (9) Carbon Black content ( Clause 8.3) (10) For Size above 250 mm
281 IS 14543 (2016) Packaged drinking water (Other Than Packaged Natural Mineral Water) - Specification (Second Revision) - - - View breakup
-
Partial - Excluding Cyanide, Radio Active Elements. For testing of Pesticide Residues please indicate accordingly
282 IS 1786 (2008) High strength deformed steel bars and wires for concretere inforcement - Specification (Fourth Revision) - - - View breakup
-
Partial - Test facilities are not available for the following: (1) Total elongation at maximum force, (2) Pull out test (Type test) (3) Sizes above 25 mm, (4) Micro-alloy/low alloys, Nb, V, B and Ti, Cr, Cu, Ni, Mo, Nirogen and nitrogen binding elements, like Nb, V, Ti, Al

Designed, Developed and Maintained by:

Arohatech IT Services (P) Ltd.

Contact for any query/support: supportlims@bis.gov.in