BIS, Western Regional Laboratory (WRL)

BUREAU OF INDIAN STANDARDS (WESTERN REGIONAL LABORATORY), PLOT NO. E9, ROAD NO. 8, M.I.D.C, ANDHERI (EAST), MUMBAI, MAHARASHTRA, INDIA, MUMBAI, Mumbai Suburban, Maharashtra, 400093
- wrol@bis.gov.in
Scope List
Reset
255 Results
S.No. Indian Standard No. Product Grade / Type / Size / Designation etc. Testing Charges (Excl. Of Taxes) Validity Date Remark
241 IS 1293 (2019) Plugs and socket - Outlets of rated Voltage up to and including 250 Volts and rated current up to and including 16 amperes - Specification (Third Revision) UP TO 16A, 250V - View breakup
-
- -
Complete Test facility available
242 IS 398 : Part 5 (1992) Aluminium conductor for overhead transmission purposes - Specification: Part 5 aluminium conductors - Galvanized steel - Reinforced for extra high voltage (400 KV And Above) (First Revision) Except Test facility for clause 13.10, 13.11 and 13.12 11400 View breakup
-
- -
Test facility not available: 1. Breaking Load Test on Complete Conductor, 2. Surface conditioning test apparatus 3. Corona Test 4. Radio Interference Voltage Test.
243 IS 398 : Part 4 (1994) Aluminium conductors for overhead transmission purposes: Part 4 aluminium alloy stranded conductors (Aluminium - Magnesium - Silicon Type) - Specification (Third Revision) - Please see remarks View breakup
-
- -
Complete Test facility available
244 IS 398 : Part 1 (1996) Aluminium conductors for overhead transmission purposes - Specification: Part 1 aluminium stranded conductors (Third Revision) - Rs.1600/- for 7 strands, Rs.3750/- for 19 strands View breakup
-
- -
Complete Test Facility
245 IS 371 (1999) Ceiling roses - Specification (Third Revision) 6A, 250V Rs 5700/- View breakup
-
- -
-
246 IS 204 : Part 1 (1991) Tower bolts - Specification: Part 1 ferrous metals (Fifth Revision) - Rs.2100.00. View breakup
-
- -
Test facilities are not available for the following: (1) Finish
247 IS 12818 (2010) Unplasticized polyvinyl chloride (Pvc - U) screen and casing pipes for bore/tubewells - Specification (Second Revision) - Rs.6450.00 View breakup
-
- -
Remark 1: For measurement of the shore hardness of the sealing ring prepared button piece is required. Remark 2 : The following test facilities are not available: (1) For Outside Diameter above 250 mm, (2) Effect on water (3)Resistance to external blow
248 IS 398 : Part 2 (1996) Aluminium conductors for overhead transmission purposes - Specification: Part 2 aluminium conuuctors, galvanized steel - Reinforced (Third Revision) Up to 100 sq mm Please see remarks. View breakup
-
- -
Test facility not available for Cl. 13.9, 13.10 and 13.11 for size 100 sq.mm and above.
249 IS 3854 (1997) Switches for domestic and similar purposes - Specification (Second Revision) - Please see remarks. View breakup
-
- -
Complete TF is available for varieties upto and including 32 A.
250 IS 694 (2010) Polyvinyl chloride insulated unsheathed and sheathed cables/cords with rigid and flexible conductor for rated voltages up to and including 450/750 v (Fourth Revision) - Please see remarks View breakup
-
- -
Test facility not available for Copper purity test and FR/FRLSH category cables
251 IS 1554 : Part 1 (1988) Specification for pvc insulated (Heavy Duty) electric cables: Part 1 for working voltages up to and including 1100 v (Third Revision) - Rs 26700 View breakup
-
- -
Test facility not available for tests as per Cl. 15.1.1 of C1 and C2 category
252 IS 13334 : Part 1 (2014) Skimmed milk powder - Specification: Part 1 standard grade (Second Revision) - 10430/- View breakup
-
- -
(1) As per Cl. 5.7 The pesticide residues, heavy metals, toxins (aflatoxins and other naturally occurring toxins) and contaminants, if any, in the product shall not exceed the limits as prescribed in the Food Safety and Standards (Contaminants, Toxins and Residues) Regulations, 2011.’
253 IS 2124 (2000) Sodium bicarbonate - Specification (Second Revision) - Rs 4660/- for Pure Grade View breakup
Rs 8210/- for Analytical Reagent Grade Rs 4360/- for Refined Grade
- -
-
254 IS 4984 (2016) Polyethylene pipes for water supply - Specification (Fifth Revision) - - View breakup
-
- -
The following test facilities are not available: (1) Internal Pressure creep rupture test (2)Tensile Strength for Butt-fusion (Clause 8.8) (3) Slow Crack Growth rate test (Clause 8.10) (4) Depth of strip (Clause 6.2.1) (5) Carbon Black content ( Clause 8.3) (6) For Size above 250 mm
255 IS 1786 (2008) High strength deformed steel bars and wires for concretere inforcement - Specification (Fourth Revision) - 25780 View breakup
-
- -
Test facilities are not available for the following: (1) Total elongation at maximum force, (2) Pull out test (Type test) (3) Sizes above 25 mm, (4) Micro-alloy/low alloys, Nb, V, B and Ti, Cr, Cu, Ni, Mo, Nirogen and nitrogen binding elements, like Nb, V, Ti, Al

Designed, Developed and Maintained by:

Arohatech IT Services (P) Ltd.