IS 651 (2007) |
Glazed stoneware pipes and fittings - Specification (Sixth Revision) |
- |
-
|
- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Clause 7.4 (Acid Resistance Test) |
- |
|
|
|
Clause 7.5 (Alkali Resistance Test) |
- |
|
|
|
7.2 (Hydraulic Test) |
- |
|
|
|
7.3 (Absorption Test) |
- |
|
|
|
10.1-Table 1 (INTERNAL DIAMETER) |
- |
|
|
|
11.1-Table 1 (
Mean Thickness of Barrel and of Socket) |
- |
|
|
|
14-Table 1 (Internal Depth of Socket) |
- |
|
|
|
14-Table 2 (Excess Shoulder Measurment) |
- |
|
|
|
14-Table 3 (Length of Grooving of Spigot) |
- |
|
|
|
12.2 (STRAIGHTNESS OF BARRELS OR STRAIGHT AND TAPER PIPES-Length of Junction) |
- |
|
|
|
13.1-Table 2 (Dimensions of One-Quarter Bends-Internal Diameter) |
- |
|
|
|
14 (The interior of the sockets shall be conical, having a minimum taper) |
- |
|
|
|
15 (GROOVING Length) |
- |
|
|
|
15 (GROOVING Depth) |
- |
|
|
|
|
Partial
|
|
- |
Test facilities are not available for the following:
1. Crushing Test |
242 |
IS 432 : Part 2 (1982) |
Mild Steel and Medium Tensile Steel Bars and Hard-Drawn Steel Wire for Concrete Reinforcement: Part 2 Hard-Drawn Steel Wire |
- |
-
|
- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Clause 3.1.1 (Sulphur) |
- |
|
|
|
Clause 3.1.1 (Phosphorus) |
- |
|
|
|
Cl 5 & 6 (Diameter) |
- |
|
|
|
Cl 7 (UTM) |
- |
|
|
|
Cl 8.3 (Bending To Both Side At 90°, Then Straight) |
- |
|
|
|
|
Partial
|
|
- |
Test facilities are not available for the following:
1. Nitrogen |
243 |
IS 432 : Part 1 (1982) |
Mild Steel and Medium Tensile Steel Bars and Hard-Drawn Steel Wire for Concrete Reinforcement: Part 1 Mild Steel and Medium Tensile Steel Bars |
- |
-
|
- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Cl 6.2 (Diameter & Ovality) |
- |
|
|
|
Cl 6.2 (Weight) |
- |
|
|
|
Cl 8.2 (Bend test) |
- |
|
|
|
Cl 9.3 (Press) |
- |
|
|
|
Clause -4, 4.1 ( CARBON) |
- |
|
|
|
Clause -4, 4.1 (SULPHUR) |
- |
|
|
|
Clause -4, 4.1 (PHOSPHURS) |
- |
|
|
|
Clause -4, 4.1 (MANGANESE) |
- |
|
|
|
Clause -4, 4.1 (SILICON) |
- |
|
|
|
|
Partial
|
|
- |
Test facilities are not available for the following:
1. Micro-alloying elements, Cu, Al, Nitrogen |
244 |
IS 362 (1991) |
Parliament Hinges -specification |
- |
-
|
- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
5.1-able 2 (Dlmenslons for Aluminium Alloy Parliament Hinges-A) |
- |
|
|
|
5.1-able 2 (Dlmenslons for Aluminium Alloy Parliament Hinges-B) |
- |
|
|
|
5.1-able 2 (Dlmenslons for Aluminium Alloy Parliament Hinges-C) |
- |
|
|
|
5.1-able 2 (Dlmenslons for Aluminium Alloy Parliament Hinges-D) |
- |
|
|
|
5.1-able 2 (Dlmenslons for Aluminium Alloy Parliament Hinges-E) |
- |
|
|
|
5.1-able 3 (Dimensions for Cast Brass Parliament Hinges-A) |
- |
|
|
|
5.1-able 3 (Dimensions for Cast Brass Parliament Hinges-B) |
- |
|
|
|
5.1-able 3 (Dimensions for Cast Brass Parliament Hinges-C) |
- |
|
|
|
5.1-able 3 (Dimensions for Cast Brass Parliament Hinges-D) |
- |
|
|
|
5.1-able 3 (Dimensions for Cast Brass Parliament Hinges-E) |
- |
|
|
|
5.1-able 2 (Dlmenslons for Aluminium Alloy Parliament Hinges-Thickness of Flap) |
- |
|
|
|
5.1-able 3 (Dimensions for Cast Brass Parliament Hinges-Thickness of Flap) |
- |
|
|
|
5.1-Table 4 (Dimensions for Mild Steel Parliament Hinges-A) |
- |
|
|
|
5.1-Table 4 (Dimensions for Mild Steel Parliament Hinges-B) |
- |
|
|
|
5.1-Table 4 (Dimensions for Mild Steel Parliament Hinges-C) |
- |
|
|
|
5.1-Table 4 (Dimensions for Mild Steel Parliament Hinges-D) |
- |
|
|
|
5.1-able 2 (Dlmenslons for Aluminium Alloy Parliament Hinges-d) |
- |
|
|
|
5.1-Table 4 (Dimensions for Mild Steel Parliament Hinges-d) |
- |
|
|
|
5.1-Table 4 (Dimensions for Mild Steel Parliament Hinges-Thickness of Flap) |
- |
|
|
|
6.3 (MANUFACTURE-Pins) |
- |
|
|
|
|
Partial
|
|
- |
Test facilities are not available for the following:
(1) Finish |
245 |
IS 281 (2009) |
Mild steel sliding door bolts for use with padlocks - Specification (Fourth Revision) |
- |
-
|
- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
6-Table 1 (DIMENSIONS AND TOLERANCES-A) |
- |
|
|
|
6-Table 1 (DIMENSIONS AND TOLERANCES-B) |
- |
|
|
|
6-Table 1 (DIMENSIONS AND TOLERANCES-C) |
- |
|
|
|
6-Table 1 (DIMENSIONS AND TOLERANCES-D) |
- |
|
|
|
6-Table 1 (DIMENSIONS AND TOLERANCES-E) |
- |
|
|
|
6-Table 1 (DIMENSIONS AND TOLERANCES-F) |
- |
|
|
|
6-Table 1 (DIMENSIONS AND TOLERANCES-G) |
- |
|
|
|
6-Table 1 (DIMENSIONS AND TOLERANCES-H) |
- |
|
|
|
6-Table 1 (DIMENSIONS AND TOLERANCES-J) |
- |
|
|
|
6-Table 1 (DIMENSIONS AND TOLERANCES-T) |
- |
|
|
|
6-Table 1 (DIMENSIONS AND TOLERANCES-no. of 8m Sqire Holes for carriage bolts for plate and sockets) |
- |
|
|
|
6-Table 1 (DIMENSIONS AND TOLERANCES-no. of 8m Sqire Holes for carriage bolts for Staple) |
- |
|
|
|
|
Partial
|
|
- |
Test facilities are not available for the following:
(1) Finish |
246 |
IS 280 (2006) |
Mild steel wire for general engineering purposes (Fourth Revision) |
- |
-
|
- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Cl 7 & Table 1 (Diameter & Difference Between Two Reading On Any Two Diameters) |
- |
|
|
|
Cl 9 (Tensile Test On UTM) |
- |
|
|
|
6 AND AS PER IS 7887 (PHOSPHORUS) |
- |
|
|
|
6 AND AS PER IS 7887 (SULPHUR) |
- |
|
|
|
6 AND AS PER IS 7887 (MANGANESE) |
- |
|
|
|
6 AND AS PER IS 7887 (SILICON) |
- |
|
|
|
6 AND AS PER IS 7887 (CARBON) |
- |
|
|
|
|
Partial
|
|
- |
Test facilities are not available for the following:
1. Al, Cu |
247 |
IS 278 (2009) |
Galvanized steel barbed wire for fencing - Specification (Fourth Revision) |
- |
-
|
- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
12.1 (Tensile Strength) |
- |
|
|
|
12.1 (Breaking load) |
- |
|
|
|
12.3 (Ductility) |
- |
|
|
|
12.2.1 (Mass of zinc coating (line wire)) |
- |
|
|
|
12.2.2 (Mass of zinc coating (point wire)) |
- |
|
|
|
12.2 (Uniformity of zinc coating) |
- |
|
|
|
9.1 (Freedom from defects) |
- |
|
|
|
9.2 (Freedom from defects) |
- |
|
|
|
7.2 (Manufacture) |
- |
|
|
|
5 Table-1 (Sizes No. of Lays between the two consequtive barbs) |
- |
|
|
|
5 Table-1 (Sizes Distance between two barbs) |
- |
|
|
|
5 Table-1 (Sizes Mass of Completed barbed wire) |
- |
|
|
|
5 Table-1 (Sizes Diamater of Point wire) |
- |
|
|
|
5 Table-1 (Sizes Diameter of Line wire) |
- |
|
|
|
4 (Type A/Type B) |
- |
|
|
|
|
Partial
|
|
- |
1. Al, Cu, |
248 |
IS 210 (2009) |
Grey iron castings - Specification (First Revision) |
- |
-
|
- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
13 (SIZE OF TEST BARS-Diameter) |
- |
|
|
|
13 (SIZE OF TEST BARS-Length) |
- |
|
|
|
15, Table 3 (TENSIL.E TEST- IS 1608 Part1 ) |
- |
|
|
|
16, Table 3 (Hardness Test) |
- |
|
|
|
18 (HYDROSTATIC TEST) |
- |
|
|
|
|
Partial
|
|
- |
Test facilities are not available for the following:
(1)Hydrostatic Test
(2) Brinell Hardness test |
249 |
IS 205 (1992) |
Non - Ferrous metal butt specification (Fourth Revision) |
- |
-
|
- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
6.3.1- Table 2,3,4,5 & Fig-1 & 2 (Screw Holes) |
- |
|
|
|
5.1- Table 2,3,4,5 & Fig-1 & 2 (Dimensions- 1. Holes for Screw Desination 2. No. of screw Holes) |
- |
|
|
|
5.2 ,Table 6 (Tolerances-Tolerances on dimensions of hinges ) |
- |
|
|
|
|
Partial
|
|
- |
Test facilities are not available for the following:
(1) Anodizing thickness |
250 |
IS 204 : Part 2 (1992) |
Tower bolts - Specification: Part 2 non - Ferrous metals (Fifth Revision) |
- |
-
|
- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
6.1- Table 1 (Dimension of Barrel tower bolts-1.Size 2.Length of Bolt or Barrel-(A or B) 4.Width of Barrel-C 5.Dia of Bolt-D 6.Length of Socket-E 7.Thickness of Metal of Barrel (Brass or Zink Alloy/Aluminium alloy/Sheet Brass)-F 8.Dia of bore of barrel or socket- G ) |
- |
|
|
|
6.2- Table 2 (Dimension of Skeleton Tower Bolts 1.Size 2.Length of Bolt -A 3.Length of Bolt Plate -B 4.Width of Bolt Plate or Staple-C 5.Dia of Bolt-D 6.Length of Staple-E 7.Thickness of Plate or Socket (Brass /Aluminium alloy or Zink Alloy)-F 8.Dia of bore of Plate or Staple-G 9.Dia of shank of Knob ) |
- |
|
|
|
6.2- Table 3 (PACKING) |
- |
|
|
|
|
Partial
|
|
- |
Test facilities are not available for the following:
(1) Finish |
251 |
IS 277 (2018) |
Galvanized steel strips and sheets (Plain And Corrugated) - Specification (Seventh Revision) |
- |
-
|
- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Cl 8.1 (UTM) |
- |
|
|
|
Cl 8.2 (Press) |
- |
|
|
|
Cl 13 (Weight) |
- |
|
|
|
Cl 14 (Length, Width & Thickness) |
- |
|
|
|
Cl 10 (Galvanising Test) |
- |
|
|
|
7.1 & 10.2 (Mass of Coating: Single Spot Test) |
- |
|
|
|
7.1 & 10.2 (Mass of Coating: Triple Spot Test) |
- |
|
|
|
5.1 (phosphorus) |
- |
|
|
|
5.1 (silicon ) |
- |
|
|
|
5.1 (manganese) |
- |
|
|
|
5.1 (sulphur) |
- |
|
|
|
5.1 (carbon) |
- |
|
|
|
|
Partial
|
|
- |
Test facilities are not available for the following:
1. Ti, Al, Cu, micro-alloying element, Boron |
252 |
IS 14255 (1995) |
Aertal bunched cables - For working voltages up to and including 1100 Volts - Specification |
- |
-
|
- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
4.1 (Phase/Street Lighting conductor) |
- |
|
|
|
4.2 (Messenger (Neutral Conductor or Otherwise)) |
- |
|
|
|
5.1 (Insulation) |
- |
|
|
|
6.1 (Flexibility class) |
- |
|
|
|
6.2 (Compactness) |
- |
|
|
|
6.2 (No of strands) |
- |
|
|
|
6.2 (Surface) |
- |
|
|
|
6.3 (Protective barrier) |
- |
|
|
|
6.4 (size of street lighting conductor) |
- |
|
|
|
6.5 (Size of messenger conductor ) |
- |
|
|
|
6.6 (Joints in messenger conductor ) |
- |
|
|
|
6.6 (Direction of outer layer) |
- |
|
|
|
7.1 (Insulation) |
- |
|
|
|
7.2 ( Thickness of insulation) |
- |
|
|
|
7.3 (Tolerance on thickness of insulation ) |
- |
|
|
|
7.4 (Aplication of the insulation ) |
- |
|
|
|
7.5 (Colour of the insulation ) |
- |
|
|
|
8.1 (Core identification) |
- |
|
|
|
8.2 (Core identification) |
- |
|
|
|
8.3 (Identification by other means) |
- |
|
|
|
9.1 (Assembly (Laying up)) |
- |
|
|
|
9.2 (Assembly (Laying up)) |
- |
|
|
|
9.3 (Direction of lay) |
- |
|
|
|
10.1 a) i) (Tests on phase/street light conductor: tensile test - Test method IS10810:Part 2) |
- |
|
|
|
10.1 a) ii) (Wrapping test - 10810: Part 3) |
- |
|
|
|
10.1 a) iii) (Resistance test - IS10810: Part 5) |
- |
|
|
|
10.1 b) i) (Test on messenger conductor: Breaking load - IS 10810: Part 2) |
- |
|
|
|
10.1 b) ii) (Test on messenger conductor: Elongation test - Cl 11.3) |
- |
|
|
|
10.1 b) iii) (Test on messenger conductor: Resistance test - IS 10810: Part 5) |
- |
|
|
|
10.1 c) i) (Physical tests for XLPE Insulation:
Tensile strength - IS 10810: Part 7) |
- |
|
|
|
10.1 c) i) (Physical tests for XLPE Insulation:
elongation at break - IS 10810: part 7) |
- |
|
|
|
10.1 c) ii) (Ageing in air oven : Tensile strength variation - IS 10810:Part 11) |
- |
|
|
|
10.1 c) ii) (Ageing in air oven : Elongation variation- IS 10810: Part 11) |
- |
|
|
|
10.1 c) iii) (Hot set test: Elongation under load - IS 10810: Part 30) |
- |
|
|
|
10.1 c) iii) (Hot set test: Permanent elongation (set) after cooling - IS 10810: Part 30) |
- |
|
|
|
10.1 c) iv) (Shrinkage test : Shrinkage - 10810:Part 12) |
- |
|
|
|
10.1 c) iv) (Shrinkage test : Crack Observed - 10810:Part 12) |
- |
|
|
|
10.1 c) v) (Water ahsorption (Gravimetric) - IS 10810: Part 33 ) |
- |
|
|
|
10.1 d) i) (Physical test for PE insulation:
Tensile strength - IS 10810: Part 7 ) |
- |
|
|
|
10.1 d) i) (Physical test for PE insulation: elongation at break - IS 10810: Part 7) |
- |
|
|
|
10.1 f) (Insulation resistance (Volume resistivity) test a) volume resistivity at 27°C - IS 10810: Part 43) |
- |
|
|
|
10.1 f) (Insulation resistance (Volume resistivity) test b) volume resistivity at 70°C - IS 10810: Part 43) |
- |
|
|
|
10.1 g) (High voltage test - IS10810:Part 45) |
- |
|
|
|
|
Complete
|
|
- |
Complete test facility is available |
253 |
IS 636 (2018) |
Non - Percolating flexible fire fighting delivery hose - Specification (Fourth Revision) |
- |
-
|
- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Cl.6.2 (The internal diameter of the hose shall be measured by
a suitable conical plug gauge and shall conform to the
specified diameter with a tolerance of plus 2 and minus
0.0 mm.) |
- |
|
|
|
Cl.6.4 (The average mass of hose per meter of 2 m length,
without couplings attached, shall not be more than that
prescribed in Table 1. For the determination of mass,
sample of the hose shall be conditioned at 27 ± 2°C and
65 ± 5 percent relative humidity for a period of at least
48 h and then shall be weighed under the same conditions.) |
- |
|
|
|
Cl.6.5 (For 30 m length of dry hose without couplings, the coil
diameter shall not exceed 45 cm for Type 1, 50 cm for
Type 2 and 55 cm for Type 3.) |
- |
|
|
|
Cl.6.6 (Each hose length shall be subjected to an internal hydraulic pressure of 23 kgf/cm² in accordance with 8.1 of IS 443
(Part 3) increasing the pressure at the rate not exceeding
10 kgf/cm² per min and maintaining it for 1 min. Within
this 1 min, the hose shall neither develop any leakage or
sweating, nor shall any thread in the jacket break.) |
- |
|
|
|
Cl.6.7 (A test length of hose, 1 m clear of fittings when
subjected to an internal hydraulic pressure in
accordance with 8.3 of IS 443 (Part 3) while increasing
the pressure at the rate not exceeding 10 kgf/cm2 per
min shall not burst or show leakage before a pressure
of 38 kgf/cm2 is reached) |
- |
|
|
|
Cl.6.8 (There shall be no sign of leakage or rupture and no thread in the jacket shall break after retaining the internal hydraulic pressure of 23 kgf/cm2 for 30 seconds.) |
- |
|
|
|
Cl.6.10 (The increase in diameter shall not be more than 10% at an internal hydraulic pressure of 10 kgf/cm2 for 2 minutes.) |
- |
|
|
|
Cl 6.11 (Adhesion (Cl. 6.11.1)) (Rate of separation shall not exceed 25 mm/min 1) Cover) |
- |
|
|
|
Cl 6.11 (Adhesion (Cl. 6.11.1)) (Rate of separation shall not exceed 25 mm/min 2) Jet) |
- |
|
|
|
Cl.6.11 Acccleraled Ageing Test (Cl. 6.11.2) - 1) (After ageing, there shall be no tackiness on the surface of lining or the surface of the cover. ) |
- |
|
|
|
Cl.6.11 Acccleraled Ageing Test (Cl. 6.11.2) - 2) (shall meet the requirements. given in Cl.6.7 (A test length of hose, 1 m clear of fittings when
subjected to an internal hydraulic pressure in
accordance with 8.3 of IS 443 (Part 3) while increasing
the pressure at the rate not exceeding 10 kgf/cm2 per
min shall not burst or show leakage before a pressure
of 38 kgf/cm2 is reached)) |
- |
|
|
|
Cl.6.11 Acccleraled Ageing Test (Cl. 6.11.2) - 3) (Rate of separation shall not exceed 25 mm/min 1) Cover) |
- |
|
|
|
Cl.6.11 Acccleraled Ageing Test (Cl. 6.11.2) - 3) (Rate of separation shall not exceed 25 mm/min 2) Jet) |
- |
|
|
|
Cl.6.5 (For 30 m length of dry hose without couplings, the coil
diameter shall not exceed 45 cm for Type 1, 50 cm for
Type 2 and 55 cm for Type 3.) |
- |
|
|
|
Cl.6.6 (Each hose length shall be subjected to an internal hydraulic pressure of 23 kgf/cm² in accordance with 8.1 of IS 443
(Part 3) increasing the pressure at the rate not exceeding
10 kgf/cm² per min and maintaining it for 1 min. Within
this 1 min, the hose shall neither develop any leakage or
sweating, nor shall any thread in the jacket break.) |
- |
|
|
|
Cl.6.7 (A test length of hose, 1 m clear of fittings when
subjected to an internal hydraulic pressure in
accordance with 8.3 of IS 443 (Part 3) while increasing
the pressure at the rate not exceeding 10 kgf/cm2 per
min shall not burst or show leakage before a pressure
of 38 kgf/cm2 is reached) |
- |
|
|
|
Cl.6.8 (There shall be no sign of leakage or rupture and no thread in the jacket shall break after retaining the internal hydraulic pressure of 23 kgf/cm2 for 30 seconds.) |
- |
|
|
|
Cl.6.9 (The increase in length shall not exceed 6 percent at an internal hydraulic pressure of 10 kgf/cm2 for 2 minutes.) |
- |
|
|
|
Cl.6.3 (Unless specified otherwise, the standard length shall
be 30 m. Unless otherwise specified, a tolerance of ± 2
percent shall be permitted on the length prescribed for
the hose by the purchaser but the total of all lengths of
hose supplied shall be not less than the total quantity
specified by the purchaser.) |
- |
|
|
|
Cl.6.11 Acccleraled Ageing Test (Cl. 6.11.2) - 3) (Rate of separation shall not exceed 25 mm/min 2) Jet) |
- |
|
|
|
Cl.6.11 Acccleraled Ageing Test (Cl. 6.11.2) - 2) (shall meet the requirements. given in Cl.6.7 (A test length of hose, 1 m clear of fittings when
subjected to an internal hydraulic pressure in
accordance with 8.3 of IS 443 (Part 3) while increasing
the pressure at the rate not exceeding 10 kgf/cm2 per
min shall not burst or show leakage before a pressure
of 38 kgf/cm2 is reached)) |
- |
|
|
|
Cl.6.13 (When tested in accordance with Annex D, the amount
of moisture absorbed shall not exceed 0.20 kg/m2 for
Type 2 hoses and 0.02 kg/m2 for Type 3 hoses.) |
- |
|
|
|
Cl.6.14 (When tested by the method described in Annex E, none
of the test samples shall burst at less than 8 s of the
application of the hot cube for Type 2 and 20 s for
Type 3 hose.) |
- |
|
|
|
Cl.6.12 (When determined by the method described in Annex C,
the average number of cycles completed before bursting
of three test pieces, shall not be less than the value
specified in Table 2.) |
- |
|
|
|
|
Partial
|
|
- |
Test facilities are not available for the following:
1) Pressure loss( Cl. 6.18)
2) Ozone Resistance (Cl 6.16)
3) Hot surface Resistance (Cl 6.17)
4) oil resistance ( CL 6.15 ) ,
5) Water pick ( Cl 6.13 ) |
254 |
IS 9968 : Part 1 (1988) |
Specification for elastomer insulatedcables: Part 1 for working voltages up to and including 1100 volts (First Revision) |
- |
-
|
- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
3.1 ( Copper Cooduetor) |
- |
|
|
|
3.2 (Aluminium conductor) |
- |
|
|
|
4.1 (INSULATION : lnsulation for General Service) |
- |
|
|
|
4.2 (INSULATION : Heat Resisting insulation) |
- |
|
|
|
4.3 (INSULATION : Silicone Rubber Insulation) |
- |
|
|
|
5.1 (TAPE : Proofed Tape) |
- |
|
|
|
5.2 (TAPE : 2 Polyethyl_ Terephthalate ( PETP ) Tape or
Plastic: Tape or Any Other SlIIitable Tape ) |
- |
|
|
|
5.3 (TAPE : Giass Tape) |
- |
|
|
|
6.1 (FILLERS : ) |
- |
|
|
|
7.1 (BRAID : Textile Braid) |
- |
|
|
|
7.2 (BRAID : Glass Braid ) |
- |
|
|
|
8.1 (SHEATH : General Service Insulated Cables and Flexible
Cords) |
- |
|
|
|
8.2 (SHEATH :Heat Resisting Insulated Cables) |
- |
|
|
|
9.1 (PresenRtive Compound) |
- |
|
|
|
9.2 (Varnish) |
- |
|
|
|
10 ( Conductor ) |
- |
|
|
|
11 (Separator tape) |
- |
|
|
|
12.2 (Insulation : Thickness of Insufatien) |
- |
|
|
|
12.4 (Insulation : Allplication of Insulation) |
- |
|
|
|
13 (CORE IDENTiFICATlON) |
- |
|
|
|
14 (Tape) |
- |
|
|
|
15 (BRAIDING) |
- |
|
|
|
16 (COMPOUNDING AND VARNISHING) |
- |
|
|
|
17 (LAYING UP OF CORES) |
- |
|
|
|
18 ( Binder tape) |
- |
|
|
|
19.2 (Sheath : Thickness of Sheath) |
- |
|
|
|
19.4 ( Sheath :Colour) |
- |
|
|
|
20 ( Overall diameter) |
- |
|
|
|
21. (b) (Annealing Test (for coper)) |
- |
|
|
|
21. (c) ( Tensile Test (for aluminium)) |
- |
|
|
|
21. (d) ( Wrapping Test (for aluminium)) |
- |
|
|
|
21. (e) (Conductor Resistance ) |
- |
|
|
|
21.1 ( Tensile strength ) |
- |
|
|
|
22.1 ( Elongation) |
- |
|
|
|
21.1 (type test : Ageing In air oven) |
- |
|
|
|
21.1 (type test : Hot set elongation) |
- |
|
|
|
21.1 (type test : Tear resistance ) |
- |
|
|
|
22.2 (type test :Insulauon resistance High voltage (water immersron ) test) |
- |
|
|
|
22.2 (type test : Flammability test
( applicable to cables
finished With SE 3 and
SE 4 sheaths only)
) |
- |
|
|
|
23 (identification) |
- |
|
|
|
|
Partial
|
|
- |
The following test facilities for clauses are not available:
1. Tear resistance test.
2. Water absorption (Electrical) Test for IE2 type elastomeric insulation |
255 |
IS 9857 (1990) |
Welding cables - Specification (First Revision) |
- |
-
|
- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
4 (Conductor : Material ) |
- |
|
|
|
5 (SEPARATOR) |
- |
|
|
|
6 (COVERING) |
- |
|
|
|
7 (CONDUCTOR : CONSTRUCTION ) |
- |
|
|
|
8 (S E P A R A T O R) |
- |
|
|
|
9.1 (C O V E R I N G : Application ) |
- |
|
|
|
9.2 (T h i c k n e s s o f C o v e r i n g) |
- |
|
|
|
9.3 (T o l e r a n c e on Thickness o f C o v e r i n g) |
- |
|
|
|
9.4 (A p p l i c a t i o n of C o v e r i n g) |
- |
|
|
|
9.5 (Colour of C o v e r i n g) |
- |
|
|
|
10.1 a) 1) (Annealing test - IS 10810: Part 1) |
- |
|
|
|
10.1 a) 2) (Conductor resistance tes - IS 10810 : Part 5) |
- |
|
|
|
10.1 c) 1) (Physical tests for
covering : Tensile strength ) |
- |
|
|
|
10.1 c) 1) (Physical tests for
covering : Elongation at break ) |
- |
|
|
|
10.1 c) 2) (Physical tests for
covering - Ageing in Air oven : Tensile strength variation) |
- |
|
|
|
10.1 c) 2) (Physical tests for
covering -Ageing in Air oven : Elongation at break ) |
- |
|
|
|
10.1 c) 2) (Physical tests for
covering - Ageing in Air oven : Tensile strength ) |
- |
|
|
|
10.1 c) 2) (Physical tests for
covering -Ageing in Air oven : Elongation variation at break ) |
- |
|
|
|
10.1 c) 5) (Hot set test ) |
- |
|
|
|
10.1 c) 5) (Permanent set ) |
- |
|
|
|
11.1 (High Voltage Test ( Water Immersion
Test )) |
- |
|
|
|
11.2 (Spark Test) |
- |
|
|
|
11.3 (Static Flexibility Test) |
- |
|
|
|
11.4 (Flammability Test) |
- |
|
|
|
12.1 (Manufacturer's Identification) |
- |
|
|
|
12.2 (Cable Identification) |
- |
|
|
|
12.3 (Cable Code) |
- |
|
|
|
13.1 (Packing ) |
- |
|
|
|
13.2 (Marking) |
- |
|
|
|
14 (CABLE RATINGS) |
- |
|
|
|
15 (VOLTAGE DROP) |
- |
|
|
|
|
Complete
|
|
- |
Complete test facility is available |
256 |
IS 9537 : Part 3 (1983) |
Specification for conduits for electrical installations: Part 3 rigid plain conduits of insulating meterials |
- |
-
|
- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
6.1 (Marking) |
- |
|
|
|
6.2 (Durability of Marking as per 6.4 of IS: 9537 (Part 1)-1980) |
- |
|
|
|
6.3 (Standard Mark on Conduit) |
- |
|
|
|
7.1.1 (Maximum and minimum outside diameter of socket) |
- |
|
|
|
7.1.1 Table-2 (Length of Socket end) |
- |
|
|
|
7.1.2 (Maximum and minimum outside diameter of conduit) |
- |
|
|
|
7.2 (Minimum inside diameter of conduit) |
- |
|
|
|
7.3 (Length of conduit) |
- |
|
|
|
7.4 (Unifomity of The wall Thickness) |
- |
|
|
|
8.1 (Construction as per clause 8 of IS: 9537 (Part 1)-1980) |
- |
|
|
|
9.2 (Bending Test i) At Room Temp ii) At Low Temp (-5 ±2°C)) |
- |
|
|
|
9.3 (Compression Test as per caluse 9.3 of IS: 9537 (Part 1)-1980) |
- |
|
|
|
9.4 (Impact Test as per clause 9.4 of IS: 9537 (Part 1)-1980) |
- |
|
|
|
9.5 (Collapse Test as per clause 9.5 of IS: 9537 (Part 1)-1980) |
- |
|
|
|
10 (Resistance to Heat -Ball presure test) |
- |
|
|
|
11 (Resistance to burning as per clause 11 of IS: 9537 (Part 1)-1980) |
- |
|
|
|
12 (Electrical Characteristics-Test for electric strength as per clause 12.1.1 of IS: 9537 (Part 1)-1980) |
- |
|
|
|
12 (Electrical Characteristics-Insulation resistance test as per clause 12.1.2 of IS: 9537 (Part 1)-1980) |
- |
|
|
|
9.3 (Compression Test (after removal of force) as per caluse 9.3.3 of IS: 9537 (Part 1)-1980) |
- |
|
|
|
|
Complete
|
|
- |
Complete test facility is available |
257 |
IS 8783 : Part 4 : Sec 3 (1995) |
Winding wires for submersible motors - Specification: Part 4 specification for individual wires: Sec 3 polyester and polypropylene insulated winding wires (First Revision) |
- |
-
|
- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
5.1 (The winding wire shall either be wound on spools / reels conforming to IS 482-1981. or supplied in a coils packed and labelled.) |
- |
|
|
|
6.1 (The winding wire shall carry following information marked on the lable on spool / reel / coil;) |
- |
|
|
|
6.1 (a) Reference to this Indian Standard;) |
- |
|
|
|
6.1 (b) Manufacturer's name,brand name or trade-mark;) |
- |
|
|
|
6.1 (c) Size of conductor / maximum overall diameter,) |
- |
|
|
|
6.1 (d) Length of conductor on spool / reel /coil;) |
- |
|
|
|
6.1 (e) Number of lengths onspool / reel / coil (if more than one);) |
- |
|
|
|
6.1 (f) Country of Manufacturer) |
- |
|
|
|
6.1 (g) Year of Manufacture.) |
- |
|
|
|
6.2 (BIS Certification Mark) |
- |
|
|
|
4 (i) Material) |
- |
|
|
|
5 (ii) Diameter [mm] Seperate wire:) |
- |
|
|
|
5 (ii) Diameter [mm] Wire taken from cable:) |
- |
|
|
|
5 (iii) Annealing test [Percentage] on Seperate wire:) |
- |
|
|
|
5 (iii) Annealing test [Percentage] on Wire taken from cable:) |
- |
|
|
|
5 (d) Resistance test [Ohm/km corrected to 20°c) |
- |
|
|
|
4.1, table 1 & 2 (a) Thickness of Polyster (mm)) |
- |
|
|
|
4.1, table 1 & 3 (b) Thickness of Polypropylene (mm)) |
- |
|
|
|
4.1, table 1 & 4 (c) Total thickness of Insulation(mm)) |
- |
|
|
|
4.2 (Application of insulation) |
- |
|
|
|
4.3 (Colour of Insuation) |
- |
|
|
|
4.4 (Overall diameter (mm)) |
- |
|
|
|
4 (Before ageing Tensile strength [N/mm²]) |
- |
|
|
|
4 (Before ageing Elongation at break [Percentage]) |
- |
|
|
|
4 (After ageing Tensile strength [N/mm²]) |
- |
|
|
|
4 (Variation on tensile strangth [Percentage]) |
- |
|
|
|
4 (After ageing Elongation at break [Percentage]) |
- |
|
|
|
4 (Variation on elongation at break [Percentage]) |
- |
|
|
|
4 (Shrinkage test [Percentage]) |
- |
|
|
|
4 (After Shrinkage Cracks found.) |
- |
|
|
|
4.1 (Water absorption test [Gravimetric] [mg/cm²]) |
- |
|
|
|
4.5 (High Voltage test [Water Immersion test] 3 KV for 1 Minute) |
- |
|
|
|
5 (The winding wire shall either be wound on spools / reels conforming to IS 482-1981. or supplied in a coils packed and labelled.) |
- |
|
|
|
6 (The winding wire shall carry following information marked on the lable on spool / reel / coil;) |
- |
|
|
|
6 (a) Reference to this Indian Standard;) |
- |
|
|
|
6 (b) Manufacturer's name,brand name or trade-mark;) |
- |
|
|
|
6 (c) Size of conductor / maximum overall diameter,) |
- |
|
|
|
6 (d) Length of conductor on spool / reel /coil;) |
- |
|
|
|
6 (e) Number of lengths onspool / reel / coil (if more than one);) |
- |
|
|
|
6 (f) Country of Manufacturer Marking) |
- |
|
|
|
6 (g) Year of Manufacture.) |
- |
|
|
|
6.2 (BIS Certification Mark) |
- |
|
|
|
|
Partial
|
|
- |
The following test facilities for clauses are not available:
Cl 4.1 Thickness of Insulation (Separate measurement of Thickness of Polypropylene and Polyester) |
258 |
IS 8783 : Part 4 : Sec 1 (1995) |
Winding wires for submersible motors - Specification: Part 4 specification for indmdual wires: Sec 1 HR PVC insulated wires (First Revision) |
- |
-
|
- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Cl.3.1 (Conductor) |
- |
|
|
|
Cl.4 (Material) |
- |
|
|
|
Cl.5.1.1 (Dimensions) |
- |
|
|
|
Cl. 6 (Annealing Test) |
- |
|
|
|
Cl 6 (Resistance Test) |
- |
|
|
|
Cl 4.1.2 (Visual examination) |
- |
|
|
|
Cl.3.2 (Dielectric Material ) |
- |
|
|
|
Cl. 4 Table 1of IS: 8783 (part 2) (Volume resistivity) |
- |
|
|
|
Cl. 4 Table 1of IS: 8783 (part 2) (Volume resistivity) |
- |
|
|
|
Cl. 4 Table 1of IS: 8783 (part 2) (Tensile strength ) |
- |
|
|
|
Cl. 4 Table 1of IS: 8783 (part 2) (Elongation) |
- |
|
|
|
Cl. 4 Table 1of IS: 8783 (part 2) (Tensile Strength) |
- |
|
|
|
Cl. 4 Table 1of IS: 8783 (part 2) (Variation) |
- |
|
|
|
Cl. 4 Table 1of IS: 8783 (part 2) (Elongation at Break ) |
- |
|
|
|
Cl. 4 Table 1of IS: 8783 (part 2) (Variation) |
- |
|
|
|
Cl. 4 Table 1of IS: 8783 (part 2) (Shrinkage test ) |
- |
|
|
|
Cl. 4 Table 1of IS: 8783 (part 2) (Shrinkage test ) |
- |
|
|
|
Cl. 4 Table 1of IS: 8783 (part 2) (Water absorption (Gravimetric) ) |
- |
|
|
|
Cl. 4 Table 1of IS: 8783 (part 2) (Hot deformation Test ) |
- |
|
|
|
Cl. 4 Table 1of IS: 8783 (part 2) (Heat shock Test ) |
- |
|
|
|
Cl.4.1 (Insulation ) |
- |
|
|
|
Cl.4.2 (Application) |
- |
|
|
|
Cl.4.3 (Colour) |
- |
|
|
|
Cl.4.4 (Overall Diameter) |
- |
|
|
|
Cl.4.5 (Finish) |
- |
|
|
|
Cl.4.6 (High Voltage Test Water Immersion ) |
- |
|
|
|
|
Complete
|
|
- |
- |
259 |
IS 7098 : Part 1 (1988) |
Specification for crosslinked polyethylene insulated pvc sheathed cables: Part 1 for working voltages up to and including 1100 volts (First Revision) |
Except C1 & C2 category. |
-
|
- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
3 (CONDUCTOR: MATERIALS) |
- |
|
|
|
4 (INSULATION : MATERIALS) |
- |
|
|
|
5.1 (FILLER AND INNER SHEATH) |
- |
|
|
|
5.2 (FILLER AND INNER SHEATH) |
- |
|
|
|
6 (ARMOURING) |
- |
|
|
|
7 (OUTER SHEATH) |
- |
|
|
|
8.1 (CONDUCTOR: CONSTRUCTION) |
- |
|
|
|
8.2 (PROTECTIVE BARRIER) |
- |
|
|
|
8.3 (SIZE OF NEUTRAL CONDUCTOR) |
- |
|
|
|
9.1 (Insulation Applied by extrusicn) |
- |
|
|
|
9.2 (Thickness of Insulation - Average) |
- |
|
|
|
9.3 (Thickness of Insulation - Minimum) |
- |
|
|
|
9.4 (Application of Insulation) |
- |
|
|
|
10.1 (Core Identification) |
- |
|
|
|
10.2 (Core Identification- Neutral) |
- |
|
|
|
10.3 (Core Identification by number ) |
- |
|
|
|
10.4 (Core Identification by number - Neutral ) |
- |
|
|
|
11 (LAVING UP OF CORES) |
- |
|
|
|
12.1 & 12.2 (Inner sheath : Application) |
- |
|
|
|
12.3 (Thickness of Inner Sheath) |
- |
|
|
|
13.1 (Armouring: Application) |
- |
|
|
|
13.1.2 (Armouring: Coverage ) |
- |
|
|
|
13.1.3 (Armouring: Direction of Lay ) |
- |
|
|
|
13.2 (Type of armour ) |
- |
|
|
|
13.3 (Armouring : Dimensions -Wire Diameter) |
- |
|
|
|
13.4 (Armour: Joint) |
- |
|
|
|
13.5 (Armouring : Resistance Test) |
- |
|
|
|
13.6 a) (ARMOURING: Tensile Strength) |
- |
|
|
|
13.6 b) (ARMOURING: Elongation ) |
- |
|
|
|
13.6 c) (ARMOURING: Torsion Test (For round wire ) ) |
- |
|
|
|
13.6 d) (ARMOURING: Winding Test(For formed wire)) |
- |
|
|
|
13.6 e) (ARMOURING: Uniformity of zinc coating) |
- |
|
|
|
13.6 f) (ARMOURING: Mass of zinc coating ) |
- |
|
|
|
13.6 g) (ARMOURING: Resistivity) |
- |
|
|
|
14.1 (Outer Sheath : Application) |
- |
|
|
|
14.2 (Colour of outer sheath) |
- |
|
|
|
14.3 (Thickness of outer sheath - AVERAGE) |
- |
|
|
|
14.3 (Thickness of outer sheath - minimum) |
- |
|
|
|
15.1 a) i) (Annealing Test ( For copper wire ) ) |
- |
|
|
|
15.1 a) ii) (Tensile test (for aluminium) - Before stranding ) |
- |
|
|
|
15.1 a) ii) (Tensile test (for aluminium) - After stranding ) |
- |
|
|
|
15.1 a) iii) (Wrapping test (for aluminium)) |
- |
|
|
|
15.1 a) iv) (Resistance test - Main conductor) |
- |
|
|
|
15.1 a) iv) (Resistance test - Neutral conductor) |
- |
|
|
|
15.1 d) i) (Phyaical tests for insulation : Tensile Test) |
- |
|
|
|
15.1 d) i) (Phyaical tests for insulation : Elongation) |
- |
|
|
|
15.1 d) ii) (Phyaical tests for insulation - Ageing in air Oven : Tensile Variation ) |
- |
|
|
|
15.1 d) ii) (Phyaical tests for insulation- Ageing in air oven : Elongation Variation ) |
- |
|
|
|
15.1 d) iii) (Phyaical tests for insulation : Hot set ) |
- |
|
|
|
15.1 d) iii) (Phyaical tests for insulation : Permanent set ) |
- |
|
|
|
15.1 d) iv) (Phyaical tests for insulation : Shrinkage ) |
- |
|
|
|
15.1 d) iv) (Phyaical tests for insulation : Shrinkage - Crack observed ) |
- |
|
|
|
15.1 d) v) (Insulation: Waterabsorption(gravimetric)) |
- |
|
|
|
15.1 e) i) (Physical tests for outer sheath : Tensile stregth) |
- |
|
|
|
15.1 e) i) (Physical tests for outer sheath : Elongation) |
- |
|
|
|
15.1 e) ii) (Physical tests for outer sheath- Ageing in air oven : Tensile stregth ) |
- |
|
|
|
15.1 e) ii) (Physical tests for outer sheath -Ageing in air oven : Elongation ) |
- |
|
|
|
15.1 e) ii) (Physical tests for outer sheath- Ageing in air oven : Tensile stregth Variation ) |
- |
|
|
|
15.1 e) ii) (Physical tests for outer sheath -Ageing in air oven : Elongation ) |
- |
|
|
|
15.1 e) iii) (Sheath: Loss of mass in air oven) |
- |
|
|
|
15.1 e) iv) (Phyaical tests for Sheath : Shrinkage ) |
- |
|
|
|
15.1 e) iv) (Phyaical tests for Sheath : Shrinkage - Crack observed ) |
- |
|
|
|
15.1 e) v) (Sheath : Hot deformation) |
- |
|
|
|
15.1 e) vi) (Sheath : Heat shock test) |
- |
|
|
|
15.1 e) vii) (Sheath : Thermalstability) |
- |
|
|
|
15.1 f) (INSULATION RESISTANCE TEST : Volume resistivity ) |
- |
|
|
|
16.2 (HIGH VOLTAGE TEST ) |
- |
|
|
|
16.3 (FLAMMABILITY TEST : Period of Burning ) |
- |
|
|
|
16.3 (FLAMMABILITY TEST : Unaffected length ) |
- |
|
|
|
17.1 (Manufacturer'. identification) |
- |
|
|
|
17.2 (cable Indentification ) |
- |
|
|
|
17.3 (cable Code ) |
- |
|
|
|
15.1 e) ii) (Physical tests for outer sheath -Ageing in air oven : Elongation Variation ) |
- |
|
|
|
|
Partial
|
|
- |
Test facility not available for tests as per Clause 15.1.1 of C1 and C2 category |
260 |
IS 4250 (1980) |
Specification for domestic electric food - Mixers (Liquidizers And Grinders) (First Revision) |
- |
-
|
- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
6 (Classification- IS 302-1 ) |
- |
|
|
|
6 (Classification- IS 302-1) |
- |
|
|
|
7.1 (Marking- IS 302-1) |
- |
|
|
|
7.1 (Marking- IS 302-1) |
- |
|
|
|
7.1 (Marking- IS 302-1) |
- |
|
|
|
7.1 (Marking- IS 302-1) |
- |
|
|
|
7.1 (Marking- IS 302-1) |
- |
|
|
|
7.1 (Marking- IS 302-1) |
- |
|
|
|
7.1 (Marking- IS 302-1) |
- |
|
|
|
7.1 (Marking- IS 302-1) |
- |
|
|
|
7.1 (Marking- IS 302-1) |
- |
|
|
|
7.1 (Marking- IS 302-1) |
- |
|
|
|
7.1 (Marking- IS 302-1) |
- |
|
|
|
7.1 (Marking- IS 302-1) |
- |
|
|
|
7.1 (Marking- IS 302-1) |
- |
|
|
|
7.2 (Marking) |
- |
|
|
|
7.1 (Marking- IS 302-1) |
- |
|
|
|
7.1 (Marking- IS 302-1) |
- |
|
|
|
7.1 (Marking- IS 302-1) |
- |
|
|
|
7.4 (Marking) |
- |
|
|
|
7.5 (Marking) |
- |
|
|
|
7.6 (Marking) |
- |
|
|
|
8 ( Protection Against Electric Shock, IS 302-1) |
- |
|
|
|
9 (Starting, IS 302-1) |
- |
|
|
|
10 (Power Input and Current, IS 302-1) |
- |
|
|
|
11 (Heating, IS 302-1) |
- |
|
|
|
11 (Heating, IS 302-1) |
- |
|
|
|
11 (Heating, IS 302-1) |
- |
|
|
|
11 (Heating, IS 302-1) |
- |
|
|
|
11 (Heating, IS 302-1) |
- |
|
|
|
13 (Electrical Insulation and Leakage Current at Operating Temperature: Leakage current, IS 302-1) |
- |
|
|
|
13 (Electrical Insulation and Leakage Current at Operating Temperature: High Voltage, IS 302-1) |
- |
|
|
|
15.1 (Moisture Resistance, IS 302-1) |
- |
|
|
|
15.2 (Moisture Resistance-Spillage test) |
- |
|
|
|
15 (Moisture Resistance, IS 302-1) |
- |
|
|
|
16 (Electrical Insulation and Leakage Current at Operating Temperature: Leakage current, IS 302-1) |
- |
|
|
|
16 (Electrical Insulation and Leakage Current at Operating Temperature: High Voltage, IS 302-1) |
- |
|
|
|
19 (Abnormal Operation, IS 302-1) |
- |
|
|
|
19 (Abnormal Operation, IS 302-1) |
- |
|
|
|
19 (Abnormal Operation, IS 302-1) |
- |
|
|
|
19 (Abnormal Operation, IS 302-1) |
- |
|
|
|
20 (Stability & Mechanical Hazards, IS 302-1) |
- |
|
|
|
20 (Stability & Mechanical Hazards, IS 302-1) |
- |
|
|
|
21 (Mechanical Strength, IS 302-1) |
- |
|
|
|
21 (Mechanical Strength, IS 302-1) |
- |
|
|
|
22.1 (Construction, IS 302-1) |
- |
|
|
|
22.2 (Construction) |
- |
|
|
|
22.3 (Construction) |
- |
|
|
|
22.4 (Construction) |
- |
|
|
|
22.5 (Construction) |
- |
|
|
|
22.6 (Construction) |
- |
|
|
|
22.8 (Construction) |
- |
|
|
|
22.9 (Construction) |
- |
|
|
|
22.1 (Construction) |
- |
|
|
|
23 (Internal Wiring, IS 302-1) |
- |
|
|
|
23 (Internal Wiring, IS 302-1) |
- |
|
|
|
23 (Internal Wiring, IS 302-1) |
- |
|
|
|
23 (Internal Wiring, IS 302-1) |
- |
|
|
|
23 (Internal Wiring, IS 302-1) |
- |
|
|
|
23 (Internal Wiring, IS 302-1) |
- |
|
|
|
23 (Internal Wiring, IS 302-1) |
- |
|
|
|
23 (Internal Wiring, IS 302-1) |
- |
|
|
|
23 (Internal Wiring, IS 302-1) |
- |
|
|
|
23 (Internal Wiring, IS 302-1) |
- |
|
|
|
24.1 (Components, IS 302-1) |
- |
|
|
|
24.1 (Components, IS 302-1) |
- |
|
|
|
24.1 (Components, IS 302-1) |
- |
|
|
|
24.2 (Components) |
- |
|
|
|
24.4 (Components) |
- |
|
|
|
24.7 (Components) |
- |
|
|
|
24.8 (Components) |
- |
|
|
|
24.9 (Components) |
- |
|
|
|
25 (Supply Connection and External Flexible Cords, IS 302-1) |
- |
|
|
|
25 (Supply Connection and External Flexible Cords, IS 302-1) |
- |
|
|
|
25 (Supply Connection and External Flexible Cords, IS 302-1) |
- |
|
|
|
25 (Supply Connection and External Flexible Cords, IS 302-1) |
- |
|
|
|
25 (Supply Connection and External Flexible Cords, IS 302-1) |
- |
|
|
|
25 (Supply Connection and External Flexible Cords, IS 302-1) |
- |
|
|
|
25 (Supply Connection and External Flexible Cords, IS 302-1) |
- |
|
|
|
25 (Supply Connection and External Flexible Cords, IS 302-1) |
- |
|
|
|
25 (Supply Connection and External Flexible Cords, IS 302-1) |
- |
|
|
|
25 (Supply Connection and External Flexible Cords, IS 302-1) |
- |
|
|
|
25 (Supply Connection and External Flexible Cords, IS 302-1) |
- |
|
|
|
25 (Supply Connection and External Flexible Cords, IS 302-1) |
- |
|
|
|
25 (Supply Connection and External Flexible Cords, IS 302-1) |
- |
|
|
|
25 (Supply Connection and External Flexible Cords, IS 302-1) |
- |
|
|
|
25 (Supply Connection and External Flexible Cords, IS 302-1) |
- |
|
|
|
25 (Supply Connection and External Flexible Cords, IS 302-1) |
- |
|
|
|
25 (Supply Connection and External Flexible Cords, IS 302-1) |
- |
|
|
|
25 (Supply Connection and External Flexible Cords, IS 302-1) |
- |
|
|
|
25 (Supply Connection and External Flexible Cords, IS 302-1) |
- |
|
|
|
25 (Supply Connection and External Flexible Cords, IS 302-1) |
- |
|
|
|
25 (Supply Connection and External Flexible Cords, IS 302-1) |
- |
|
|
|
25 (Supply Connection and External Flexible Cords, IS 302-1) |
- |
|
|
|
26 (Terminals for External Conductors, IS 302-1) |
- |
|
|
|
27 (Provision for Earthing, IS 302-1) |
- |
|
|
|
27 (Provision for Earthing, IS 302-1) |
- |
|
|
|
27 (Provision for Earthing, IS 302-1) |
- |
|
|
|
27 (Provision for Earthing, IS 302-1) |
- |
|
|
|
27 (Provision for Earthing, IS 302-1) |
- |
|
|
|
28 (Screws & Connections, IS 302-1) |
- |
|
|
|
29 (Clearances and Distances through Insulation, IS 302-1) |
- |
|
|
|
29 (Clearances and Distances through Insulation, IS 302-1) |
- |
|
|
|
30 (Resistance to Heat, Fire, Tracking, IS 302-1) |
- |
|
|
|
30 (Resistance to Heat, Fire, Tracking, IS 302-1) |
- |
|
|
|
31 (Resistance of Rusting, IS 302-1) |
- |
|
|
|
34.2 (Operational tests- Grinding coffee (for machines which have a dry grinding arrangement)) |
- |
|
|
|
34.2 (Operational tests- Grinding coffee (for machines which have a dry grinding arrangement)) |
- |
|
|
|
34.2 (Operational tests- Grinding coffee (for machines which have a dry grinding arrangement)) |
- |
|
|
|
34.3 (Whisking egg whites ) |
- |
|
|
|
34.4 (IDLI batter-Grinding of black gram) |
- |
|
|
|
34.4 (IDLI batter-Grinding of rice) |
- |
|
|
|
34.4 (IDLI batter-Grinding of rice) |
- |
|
|
|
34.4 (IDLI batter-Grinding of rice) |
- |
|
|
|
34.5.1 (a) (Operational test for juicers ) |
- |
|
|
|
34.5.1 (b) (Operational test for juicers ) |
- |
|
|
|
34.5.2 (Operational test for juicers ) |
- |
|
|
|
35 (Temperature withstand test for bowl) |
- |
|
|
|
36 (Test for controls ) |
- |
|
|
|
37 (Strength of Assembly ) |
- |
|
|
|
37 (Strength of Assembly ) |
- |
|
|
|
|
Partial
|
|
- |
The following test facilities are not available:
1. Cl.14 Transient Overvoltage test (as per IS 302-1)
2. Cl.19.11 and 19.12 Abnormal Operation test (as perIS 302-1) (for electronic circuit)
3. Cl 24 component test as per IS302-1 |
261 |
IS 3975 (1999) |
Low carbon galvanized steel wires, formed wires and tapes for armouring of cables - Specification (Third Revision) |
- |
-
|
- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Clause 6.1, Table-1 (Sulphur) |
- |
|
|
|
Clause 6.1, Table-1 (Phosphorus) |
- |
|
|
|
9.1 (Galvanizing Requirements ) |
- |
|
|
|
14 (a) (Marking) |
- |
|
|
|
14 (b) (Marking) |
- |
|
|
|
14 (c) (Marking) |
- |
|
|
|
14 (d) (Marking) |
- |
|
|
|
14 (e) (Marking) |
- |
|
|
|
14 (f) (Marking) |
- |
|
|
|
14 (g) (Marking) |
- |
|
|
|
14.2 (Marking) |
- |
|
|
|
7 (Dimensions) |
- |
|
|
|
7 (Dimensions) |
- |
|
|
|
7 (Dimensions) |
- |
|
|
|
7 (Dimensions) |
- |
|
|
|
7 (Dimensions) |
- |
|
|
|
11 (Freedom from defects) |
- |
|
|
|
9.1 (Galvanizing Requirements ) |
- |
|
|
|
9.2 (Galvanizing Requirements ) |
- |
|
|
|
9.3 (Galvanizing Requirements ) |
- |
|
|
|
8.1 (Mechanical Properties (as per table 5 of IS 1608)) |
- |
|
|
|
8.1 (Mechanical Properties (as per table 5 of IS 1608)) |
- |
|
|
|
8.2 (Mechanical Properties (as per IS 1717)) |
- |
|
|
|
8.3 (Mechanical Properties (as per IS 1755)) |
- |
|
|
|
8.4 (Mechanical Properties (as per IS 10810(Part- 42))) |
- |
|
|
|
14 (Marking) |
- |
|
|
|
14 (b) (Marking) |
- |
|
|
|
|
Partial
|
|
- |
Test facility not available for the following:
1) Dimension radius R of formed wire. |
262 |
IS 2465 (1984) |
Specification for cables for motor vehicles (Second Revision) |
Complete test facility for PVC Insulated General Wiring |
-
|
- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
7.1 (Insulation) |
- |
|
|
|
7.3 (Insulation) |
- |
|
|
|
8 (Core Identification) |
- |
|
|
|
9 (Laying up of cores) |
- |
|
|
|
10.1.1 (Sheathing ) |
- |
|
|
|
10.2 (Sheathing ) |
- |
|
|
|
3 & 6 (Flexibility class) |
- |
|
|
|
3 & 6 (Construction) |
- |
|
|
|
3 & 6 (Diameter of wire(mm)) |
- |
|
|
|
3 & 6 (Annealing test) |
- |
|
|
|
3 & 6 (Persulphate Test) |
- |
|
|
|
3 & 6 (Conductor resistance Test (ohm/km at 20˚c)) |
- |
|
|
|
7.2, 10.3, 11 (Dimensions & thickness ) |
- |
|
|
|
7.2, 10.3, 11 (Dimensions & thickness ) |
- |
|
|
|
7.2, 10.3, 11 (Overall Dimension (mm)) |
- |
|
|
|
4.2 & 12.1 (Without Ageing For Insulation
Tensile Strength (N/mm²)) |
- |
|
|
|
4.2 & 12.1, (f), 1 (elongation at break (N/mm²)) |
- |
|
|
|
4.2 & 12.1, (f), 1 (Tensile Strength at break (N/mm²)) |
- |
|
|
|
4.2 & 12.1, (e), 1 (elongation test at break) |
- |
|
|
|
4.2 & 12.1, (e), 1 (Tensile strength at break) |
- |
|
|
|
4.2 & 12.1, (f), 2 (Ageing in air oven) |
- |
|
|
|
4.2 & 12.1, (f), 3 (Ageing in oxygen bomb) |
- |
|
|
|
4.2 & 12.1, (e), 2 (After Ageing in air oven) |
- |
|
|
|
4.2 & 12.1, (e), 3 (Loss of mass test (mg/cm²) of Insulation) |
- |
|
|
|
4.2 & 12.1, (e), 3 (Loss of mass test (mg/cm²) of Sheath) |
- |
|
|
|
4.2 & 12.1, (e), 4 (Hot deformation test (%) of Insulation) |
- |
|
|
|
14 (High Voltage Test) |
- |
|
|
|
15 (SPARK TEST FOR SINGLE CORE GENERAL WIRING CABLES) |
- |
|
|
|
18.1 (EFFECT OF HEAT ON FLEXIBILITY FOR IGNITION CABLES) |
- |
|
|
|
19.2 (EFFECT OF OIL ON IGNITION CABLES) |
- |
|
|
|
20.3 (EFFECT OF LUBRICATING OIL) |
- |
|
|
|
20.3 (EFFECT OF LUBRICATING OIL) |
- |
|
|
|
20.3 (EFFECT OF BRAKE FLUID) |
- |
|
|
|
20.3 (EFFECT OF BRAKE FLUID) |
- |
|
|
|
20.3 (EFFECT OF DIESEL) |
- |
|
|
|
20.3 (EFFECT OF DIESEL) |
- |
|
|
|
20.3 (Wrapping test) |
- |
|
|
|
21.1 (EFFECT OF COOLING ON FLEXIBILITY) |
- |
|
|
|
21.2 (EFFECT OF COOLING ON FLEXIBILITY) |
- |
|
|
|
21.2 (EFFECT OF COOLING ON FLEXIBILITY) |
- |
|
|
|
22.1 (FLAMMABILITY TEST) |
- |
|
|
|
22.1 (FLAMMABILITY TEST) |
- |
|
|
|
23.1 (Manufacturer's Identification) |
- |
|
|
|
23.1 (Manufacturer's Identification) |
- |
|
|
|
24.1 (PACKING AND MARKING) |
- |
|
|
|
24.2 (PACKING AND MARKING) |
- |
|
|
|
24.2.1 (PACKING AND MARKING) |
- |
|
|
|
4.2 & 12.1, (e), 4 (Hot deformation test (%) of Sheath) |
- |
|
|
|
4.2 & 12.1, (e), 5 (Heat Shock Test of Insulation) |
- |
|
|
|
4.2 & 12.1, (e), 5 (Heat Shock Test of Sheath) |
- |
|
|
|
4.2 & 12.1, (e), 6 (Shrinkage Test (%) of Insulation) |
- |
|
|
|
4.2 & 12.1, (e), 6 (Shrinkage Test (%) of Sheath) |
- |
|
|
|
|
Partial
|
|
- |
The following test facilities for ignition cables are not available:
Cl 16 Capacitance,
Cl 17 Ozone resistance,
Cl 18 Effect of heat on flexibility,
Cl 19 Effect of Oil test |
263 |
IS 1293 (2019) |
Plugs and socket - Outlets of rated Voltage up to and including 250 Volts and rated current up to and including 16 amperes - Specification (Third Revision) |
UP TO 16A, 250V |
-
|
- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
6 (RATINGS) |
- |
|
|
|
7.1.1 (Accessories Classification) |
- |
|
|
|
7.1.2 (Accessories Classification) |
- |
|
|
|
7.1.3 (Accessories Classification) |
- |
|
|
|
7.1.4 (Accessories Classification) |
- |
|
|
|
7.1.5 (Accessories Classification) |
- |
|
|
|
7.2.1 (Socket-Outlets Classification) |
- |
|
|
|
7.2.2 (Socket-Outlets Classification) |
- |
|
|
|
7.2.3 (Socket-Outlets Classification) |
- |
|
|
|
7.2.4 (Socket-Outlets Classification) |
- |
|
|
|
7.3 (Plug Classification) |
- |
|
|
|
8 (Marking) |
- |
|
|
|
9 (CHECKING OF DIMENSIONS) |
- |
|
|
|
10 (PROTECTION AGAINST ELECTRIC SHOCK) |
- |
|
|
|
11 (Provision for earthing) |
- |
|
|
|
12 (terminals) |
- |
|
|
|
13.1 (Construction of fixed Socket Outlets) |
- |
|
|
|
13.2 (Construction of fixed Socket Outlets) |
- |
|
|
|
13.3 (Construction of fixed Socket Outlets) |
- |
|
|
|
13.4 (Construction of fixed Socket Outlets) |
- |
|
|
|
13.5 (Construction of fixed Socket Outlets) |
- |
|
|
|
13.6 (Construction of fixed Socket Outlets) |
- |
|
|
|
13.7 (Construction of fixed Socket Outlets) |
- |
|
|
|
13.8 (Construction of fixed Socket Outlets) |
- |
|
|
|
13.9 (Construction of fixed Socket Outlets) |
- |
|
|
|
13.10 (Construction of fixed Socket Outlets) |
- |
|
|
|
13.11 (Construction of fixed Socket Outlets) |
- |
|
|
|
13.12 (Construction of fixed Socket Outlets) |
- |
|
|
|
13.13 (Construction of fixed Socket Outlets) |
- |
|
|
|
13.14 (Construction of fixed Socket Outlets) |
- |
|
|
|
13.15 (Construction of fixed Socket Outlets) |
- |
|
|
|
13.16 (Construction of fixed Socket Outlets) |
- |
|
|
|
13.17 (Construction of fixed Socket Outlets) |
- |
|
|
|
13.18 (Construction of fixed Socket Outlets) |
- |
|
|
|
13.19 (Construction of fixed Socket Outlets) |
- |
|
|
|
13.2 (Construction of fixed Socket Outlets) |
- |
|
|
|
13.21 (Construction of fixed Socket Outlets) |
- |
|
|
|
13.22 (Construction of fixed Socket Outlets) |
- |
|
|
|
13.23 (Construction of fixed Socket Outlets) |
- |
|
|
|
14.1 (CONSTRUCTION OF PLUGS AND PORTABLE SOCKETOUTLET) |
- |
|
|
|
14.2 (CONSTRUCTION OF PLUGS AND PORTABLE SOCKETOUTLET) |
- |
|
|
|
14.3 (CONSTRUCTION OF PLUGS AND PORTABLE SOCKETOUTLET) |
- |
|
|
|
14.4 (CONSTRUCTION OF PLUGS AND PORTABLE SOCKETOUTLET) |
- |
|
|
|
14.5 (CONSTRUCTION OF PLUGS AND PORTABLE SOCKETOUTLET) |
- |
|
|
|
14.6 (CONSTRUCTION OF PLUGS AND PORTABLE SOCKETOUTLET) |
- |
|
|
|
14.7 (CONSTRUCTION OF PLUGS AND PORTABLE SOCKETOUTLET) |
- |
|
|
|
14.8 (CONSTRUCTION OF PLUGS AND PORTABLE SOCKETOUTLET) |
- |
|
|
|
14.9 (CONSTRUCTION OF PLUGS AND PORTABLE SOCKETOUTLET) |
- |
|
|
|
14.10 (CONSTRUCTION OF PLUGS AND PORTABLE SOCKETOUTLET) |
- |
|
|
|
14.11 (CONSTRUCTION OF PLUGS AND PORTABLE SOCKETOUTLET) |
- |
|
|
|
14.12 (CONSTRUCTION OF PLUGS AND PORTABLE SOCKETOUTLET) |
- |
|
|
|
14.13 (CONSTRUCTION OF PLUGS AND PORTABLE SOCKETOUTLET) |
- |
|
|
|
14.14 (CONSTRUCTION OF PLUGS AND PORTABLE SOCKETOUTLET) |
- |
|
|
|
14.15 (CONSTRUCTION OF PLUGS AND PORTABLE SOCKETOUTLET) |
- |
|
|
|
14.16 (CONSTRUCTION OF PLUGS AND PORTABLE SOCKETOUTLET) |
- |
|
|
|
14.17 (CONSTRUCTION OF PLUGS AND PORTABLE SOCKETOUTLET) |
- |
|
|
|
14.18 (CONSTRUCTION OF PLUGS AND PORTABLE SOCKETOUTLET) |
- |
|
|
|
14.19 (CONSTRUCTION OF PLUGS AND PORTABLE SOCKETOUTLET) |
- |
|
|
|
14.20 (CONSTRUCTION OF PLUGS AND PORTABLE SOCKETOUTLET) |
- |
|
|
|
14.21 (CONSTRUCTION OF PLUGS AND PORTABLE SOCKETOUTLET) |
- |
|
|
|
14.22 (CONSTRUCTION OF PLUGS AND PORTABLE SOCKETOUTLET) |
- |
|
|
|
14.23 (CONSTRUCTION OF PLUGS AND PORTABLE SOCKETOUTLET) |
- |
|
|
|
14.24 (CONSTRUCTION OF PLUGS AND PORTABLE SOCKETOUTLET) |
- |
|
|
|
14.25 (CONSTRUCTION OF PLUGS AND PORTABLE SOCKETOUTLET) |
- |
|
|
|
14.26 (CONSTRUCTION OF PLUGS AND PORTABLE SOCKETOUTLET) |
- |
|
|
|
15 (INTERLOCKED SOCKET-OUTLETS) |
- |
|
|
|
16.1 (Resistance to Ageing) |
- |
|
|
|
16.2 (RESISTANCE TO HARMFUL INGRESS OF WATER AND TO HUMIDITY) |
- |
|
|
|
16.3 (Resistance to Humidity) |
- |
|
|
|
17.1 (RESISTANCE AND ELECTRIC STRENGTH) |
- |
|
|
|
17.2 (INSULATION RESISTANCE AND ELECTRIC STRENGTH) |
- |
|
|
|
17.3 (INSULATION RESISTANCE AND ELECTRIC STRENGTH) |
- |
|
|
|
18 (OPERATION OF EARTHING CONTACTS) |
- |
|
|
|
19 (TEMPERATURE RISE) |
- |
|
|
|
20 (Making & Breaking Capacity) |
- |
|
|
|
21 (Normal Operation) |
- |
|
|
|
22.1 (Verification of the Maximum Withdrawal Force) |
- |
|
|
|
22.2 (Verification of Minimum Withdrawal Force) |
- |
|
|
|
23.1 (FLEXIBLE CABLES AND THEIR CONNECTION) |
- |
|
|
|
23.2 (FLEXIBLE CABLES AND THEIR CONNECTION) |
- |
|
|
|
23.3 (FLEXIBLE CABLES AND THEIR CONNECTION) |
- |
|
|
|
23.4 (FLEXIBLE CABLES AND THEIR CONNECTION) |
- |
|
|
|
24.1 (MECHANICAL STRENGTH For all kinds of fixed socketoutlets) |
- |
|
|
|
24.1 (MECHANICAL STRENGTH For portable multiple and combined socket outlets with enclosures, covers or bodies other than thermoplastic or elastomeric material) |
- |
|
|
|
24.1 (MECHANICAL STRENGTH For surface mounting boxes) |
- |
|
|
|
24.2 (MECHANICAL STRENGTH For portable single socket-outlets: 1) with enclosures, covers or bodies other than thermoplastic or elastomeric material) |
- |
|
|
|
24.2 (MECHANICAL STRENGTH For portable multiple and combined socket outlets: 1) with enclosures, covers and bodies of elastomeric or thermoplastic material) |
- |
|
|
|
24.2 (MECHANICAL STRENGTH For plug 1) with enclosures, covers and bodies of elastomeric or thermoplastic material) |
- |
|
|
|
24.2 (MECHANICAL STRENGTH For plug 1) with enclosures, covers and bodies of elastomeric or thermoplastic material) |
- |
|
|
|
24.3 (MECHANICAL STRENGTH for fixed socket-outlets with a main part intended to be mounted directly on a surface) |
- |
|
|
|
24.4 (MECHANICAL STRENGTH For portable single socket-outlets: 1) with enclosures, covers or bodies of thermoplastic or elastomeric material) |
- |
|
|
|
24.4 (MECHANICAL STRENGTH For portable multiple and combined socket outlets: 1) with enclosures, covers and bodies of elastomeric or thermoplastic material) |
- |
|
|
|
24.5 (MECHANICAL STRENGTH For portable single socket-outlets: 1) with enclosures, covers or bodies of thermoplastic or elastomeric material) |
- |
|
|
|
24.5 (MECHANICAL STRENGTH For portable multiple and combined socket outlets: 1) with enclosures, covers and bodies of elastomeric or thermoplastic material) |
- |
|
|
|
24.5 (MECHANICAL STRENGTH For Plug 1) with enclosures, covers and bodies of elastomeric or thermoplastic material) |
- |
|
|
|
24.6 (MECHANICAL STRENGTH For screwed glands of accessories having an IP code higher than IP20) |
- |
|
|
|
24.7 (MECHANICAL STRENGTH For plug pins provided with insulating sleeves) |
- |
|
|
|
24.8 (MECHANICAL STRENGTH For shuttered socketoutlets) |
- |
|
|
|
24.9 (MECHANICAL STRENGTH For portable multiple and combined socket outlets (1) with enclosures, covers or bodies other than thermoplastic or elastomeric material) |
- |
|
|
|
24.9 (MECHANICAL STRENGTH For portable multiple and combined socket outlets (1) with enclosures, covers or bodies other than thermoplastic or elastomeric material) |
- |
|
|
|
24.10 (MECHANICAL STRENGTH For Plug (1) with enclosures, covers or bodies other than thermoplastic or elastomeric material) |
- |
|
|
|
24.10 (MECHANICAL STRENGTH For Plug (1) with enclosures, covers or bodies of thermoplastic or elastomeric material) |
- |
|
|
|
24.11 (MECHANICAL STRENGTH For portable socketoutlets having means for suspension on a wall) |
- |
|
|
|
24.12 (MECHANICAL STRENGTH For portable socketoutlets having means for suspension on a wall) |
- |
|
|
|
24.13 (MECHANICAL STRENGTH For portable socketoutlets having means for suspension on a wall) |
- |
|
|
|
24.14.1 (MECHANICAL STRENGTH For fixed socket-outlets) |
- |
|
|
|
24.14.2 (MECHANICAL STRENGTH For fixed socket-outlets) |
- |
|
|
|
24.14.3 (MECHANICAL STRENGTH For plugs and portable socketoutlets) |
- |
|
|
|
24.15 (MECHANICAL STRENGTH) |
- |
|
|
|
24.16 (MECHANICAL STRENGTH) |
- |
|
|
|
24.16 (MECHANICAL STRENGTH For shroud of portable socket-outlets) |
- |
|
|
|
25.1 (Resistance to heat) |
- |
|
|
|
25.2 (Resistance to heat) |
- |
|
|
|
25.3 (Resistance to heat) |
- |
|
|
|
25.4 (Resistance to heat) |
- |
|
|
|
26.1 (SCREWS, CURRENTCARRYING PARTS AND CONNECTIONS) |
- |
|
|
|
26.2 (SCREWS, CURRENTCARRYING PARTS AND CONNECTIONS) |
- |
|
|
|
26.3 (SCREWS, CURRENTCARRYING PARTS AND CONNECTIONS) |
- |
|
|
|
26.4 (SCREWS, CURRENTCARRYING PARTS AND CONNECTIONS) |
- |
|
|
|
26.5 (SCREWS, CURRENTCARRYING PARTS AND CONNECTIONS) |
- |
|
|
|
26.6 (SCREWS, CURRENTCARRYING PARTS AND CONNECTIONS) |
- |
|
|
|
26.7 (SCREWS, CURRENTCARRYING PARTS AND CONNECTIONS) |
- |
|
|
|
27.1 (CREEPAGE DISTANCES, CLEARANCES AND DISTANCES THROUGH SEALING COMPOUND) |
- |
|
|
|
27.2 (CREEPAGE DISTANCES, CLEARANCES AND DISTANCES THROUGH SEALING COMPOUND) |
- |
|
|
|
27.3 (CREEPAGE DISTANCES, CLEARANCES AND DISTANCES THROUGH SEALING COMPOUND) |
- |
|
|
|
28.1.1 (Glow-Wire Test) |
- |
|
|
|
28.2 (Resistance to Tracking) |
- |
|
|
|
29 (Resistance to Rusting) |
- |
|
|
|
30.1 (ADDITIONAL TESTS ON PINS PROVIDED WITH INSULATING SLEEVES Pressure Test at High Temperature) |
- |
|
|
|
30.2 (ADDITIONAL TESTS ON PINS PROVIDED WITH INSULATING SLEEVES Static Damp Heat Test) |
- |
|
|
|
30.3 (ADDITIONAL TESTS ON PINS PROVIDED WITH INSULATING SLEEVES Tests at Low Temperature) |
- |
|
|
|
30.4 (ADDITIONAL TESTS ON PINS PROVIDED WITH INSULATING SLEEVES Impact Test at Low Temperature) |
- |
|
|
|
8 (Marking) |
- |
|
|
|
|
Complete
|
|
- |
Complete Test facility available |
264 |
IS 398 : Part 5 (1992) |
Aluminium conductor for overhead transmission purposes - Specification: Part 5 aluminium conductors - Galvanized steel - Reinforced for extra high voltage (400 KV And Above) (First Revision) |
Except Test facility for clause 13.10, 13.11 and 13.12 |
-
|
- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
7 (elec) (Freedom from
defects) |
- |
|
|
|
13.2 (mech) (Visual Examination) |
- |
|
|
|
13.3 Table-1 (mech) (Diameter-Aluminium wires) |
- |
|
|
|
13.3 Table-2 (mech) (Diameter-Galvanized Steel wires) |
- |
|
|
|
13.5.1 Table 3 (elec) (Breaking Load on Complete conductor) |
- |
|
|
|
13.5.2 Table 1 (mech) (Breaking Load of Aluminium Wires Before Stranding) |
- |
|
|
|
13.5.2 Table 2 (mech) (Breaking Load of Steel Wires Before Stranding) |
- |
|
|
|
13.5.2 Table 2 (mech) (Breaking Load of Steel Wires After Stranding) |
- |
|
|
|
13.6.1 (mech) (Ductility by Torsion Test before stranding) |
- |
|
|
|
13.6.1 (mech) (Ductility by Torsion Test after stranding) |
- |
|
|
|
13.6.2 (mech) (Ductility by Elongation Test before stranding) |
- |
|
|
|
13.6.2 (mech) (Ductility by Elongation Test after stranding) |
- |
|
|
|
13.7.1 (mech) (Wrapping Test Aluminium Wires Before Stranding) |
- |
|
|
|
13.7.1 (mech) (Wrapping Test Aluminium Wires After Stranding) |
- |
|
|
|
13.7.2 (mech) (Wrapping Test Galvanized Steel Wires Before Stranding) |
- |
|
|
|
13.7.2 (mech) (Wrapping Test Galvanized Steel Wires After Stranding) |
- |
|
|
|
13.8 (elec) (Resistance test-Aluminium wire before Stranding) |
- |
|
|
|
14.8 (elec) (Resistance test-Aluminium wire after stranding) |
- |
|
|
|
13.9.2 (chem) (Mass of Zinc coating) |
- |
|
|
|
13.9.2 (chem) (Uniformity of Zinc coating) |
- |
|
|
|
13.4 Table-4 (mech) (Lay Ratio- Aluminium Wire Outermost Layer) |
- |
|
|
|
13.4 Table-4 (mech) (Lay Ratio- Aluminium Wire Layer Immediately Beneath Outermost Layer) |
- |
|
|
|
13.4 Table-4 (mech) (Lay Ratio- Aluminium Wire Innermost Layer of Conductors eith 3 Aluminium Wire Layers) |
- |
|
|
|
13.4 Table-4 (mech) (Lay Ratio- Steel Core (6 Wire Layer)) |
- |
|
|
|
10.4 (mech) (Direction of lay) |
- |
|
|
|
13.5.2 Table 1 (mech) (Breaking Load of Aluminium Wires After Stranding) |
- |
|
|
|
|
Partial
|
|
- |
Test facility not available:
1. Breaking Load Test on Complete Conductor,
2. Surface conditioning test apparatus
3. Corona Test
4. Radio Interference Voltage Test. |
265 |
IS 6003 (2010) |
Indented Wire For--Prestressed Concrete ” |
- |
-
|
- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
4.1.1 (Phosphorus %) |
- |
|
|
|
4.1.1 (Sulphur %) |
- |
|
|
|
Cl 7.1 (Tensile Test On UTM) |
- |
|
|
|
Cl 7.2 (Tensile Test On UTM) |
- |
|
|
|
Cl 7.3 (Reverse Bend Test) |
- |
|
|
|
Cl 7.4 (Tensile Test On UTM) |
- |
|
|
|
Cl 5.1 (Diameter) |
- |
|
|
|
Cl 6.1.2 (Weight) |
- |
|
|
|
|
Partial
|
|
- |
Test facilities are not available for the following:
1. Ni, Cr, Mo, Nb, Ti, Cu
2.Relaxation Test |
266 |
IS 398 : Part 4 (1994) |
Aluminium conductors for overhead transmission purposes: Part 4 aluminium alloy stranded conductors (Aluminium - Magnesium - Silicon Type) - Specification (Third Revision) |
- |
-
|
- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
6.1 (Freedom from Defects) |
- |
|
|
|
7.1 Table-1 (Dimensional measurement of wires) |
- |
|
|
|
7.2.2 Table-2, Table-4 (Calculated resistance of Stranded Conductor) |
- |
|
|
|
8.1 (Joints in wires-Conductors Containing Seven Wires) |
- |
|
|
|
8.2 (Joints in wires-Conductors Containing More Than Seven Wires) |
- |
|
|
|
9.2 Table 3 (Lay Ratio of stranded conductors) |
- |
|
|
|
9.3 (Direction of Lay) |
- |
|
|
|
9.4 (Multiple layers of wires) |
- |
|
|
|
11 (Packing and Marking) |
- |
|
|
|
12.2 Table 1 (Breaking Load Test- Before Stranding) |
- |
|
|
|
12.2 Table 1 (Breaking Load Test- After Stranding) |
- |
|
|
|
12.3 Table 1 (Elongation Test- Before Stranding) |
- |
|
|
|
12.3 Table 1 (Elongation Test- After Stranding) |
- |
|
|
|
12.4 Table 1 (Resistance of Aluminium wire) |
- |
|
|
|
7.2.1 (Sizes) |
- |
|
|
|
Cl. 7.2 (7.2.1, 7.2.2), Table 2 (Approx Mass) |
- |
|
|
|
|
Complete
|
|
- |
Complete Test facility available |
267 |
IS 398 : Part 1 (1996) |
Aluminium conductors for overhead transmission purposes - Specification: Part 1 aluminium stranded conductors (Third Revision) |
- |
-
|
- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
6 (Freedom from defects) |
- |
|
|
|
9.3 (Stranding) |
- |
|
|
|
12.6, Table 3 (Measurement of lay ratio) |
- |
|
|
|
12.5, Table 1 (Resistance test) |
- |
|
|
|
12.4 (Wrapping test) |
- |
|
|
|
12.3, Table-1 (Breaking load after stranding) |
- |
|
|
|
12.3, Table-1 (Breaking load before stranding) |
- |
|
|
|
12.2, Table-1 (Measurement of diameter of individual aluminium wire) |
- |
|
|
|
7.1.1 (Nominal Sizes) |
- |
|
|
|
7.2.1 (Sizes) |
- |
|
|
|
7.2.2 (Resistance) |
- |
|
|
|
8, 8.1, 8.2 (Joint in wires, except during stranding) |
- |
|
|
|
9.2 (Lay ratio) |
- |
|
|
|
9.4 (Multiple layer of wires) |
- |
|
|
|
|
Complete
|
|
- |
Complete Test Facility |
268 |
IS 371 (1999) |
Ceiling roses - Specification (Third Revision) |
6A, 250V |
-
|
- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
9 (Marking) |
- |
|
|
|
10.1 (Dimentions) |
- |
|
|
|
10.2 (Dimentions) |
- |
|
|
|
11.1 (Accessibility of live parts ) |
- |
|
|
|
11.2 (Accessibility of live parts ) |
- |
|
|
|
11.3 (Accessibility of live parts ) |
- |
|
|
|
11.4 (Accessibility of live parts ) |
- |
|
|
|
11.4.1 (Accessibility of live parts ) |
- |
|
|
|
12.1 (Provision for Earthing) |
- |
|
|
|
12.2 (Provision for Earthing) |
- |
|
|
|
13.1 (Terminals) |
- |
|
|
|
13.2 (Terminals) |
- |
|
|
|
13.3 (Terminals) |
- |
|
|
|
13.4 (Terminals) |
- |
|
|
|
13.5 (Terminals) |
- |
|
|
|
13.6 (Terminals) |
- |
|
|
|
13.7 (Terminals) |
- |
|
|
|
13.8.1 (Terminals) |
- |
|
|
|
13.8.2 (Terminals) |
- |
|
|
|
13.8.3 (Terminals) |
- |
|
|
|
14.1 (Construction) |
- |
|
|
|
14.2 (Construction) |
- |
|
|
|
14.3 (Construction) |
- |
|
|
|
14.4 (Construction) |
- |
|
|
|
15.1 (RESISTANCE TO MOISTURE AND HUMIDITY, INSULATION RESISTANCE AND ELECTRIC STRENGTH) |
- |
|
|
|
15.2 (RESISTANCE TO MOISTURE AND HUMIDITY, INSULATION RESISTANCE AND ELECTRIC STRENGTH) |
- |
|
|
|
15.3 (RESISTANCE TO MOISTURE AND HUMIDITY, INSULATION RESISTANCE AND ELECTRIC STRENGTH) |
- |
|
|
|
15.4 (RESISTANCE TO MOISTURE AND HUMIDITY, INSULATION RESISTANCE AND ELECTRIC STRENGTH) |
- |
|
|
|
15.5 (RESISTANCE TO MOISTURE AND HUMIDITY, INSULATION RESISTANCE AND ELECTRIC STRENGTH) |
- |
|
|
|
15.7 (RESISTANCE TO MOISTURE AND HUMIDITY, INSULATION RESISTANCE AND ELECTRIC STRENGTH) |
- |
|
|
|
16 (Temperature Rise Test) |
- |
|
|
|
17 (Temperature Rise Test) |
- |
|
|
|
18 (Resistance to heat) |
- |
|
|
|
19 (Resistance to abnormal heat fire and tracking) |
- |
|
|
|
19.2 (Resistance to abnormal heat fire and tracking) |
- |
|
|
|
20.1 (SCREWS, CURRENT-CARRYING PARTS AND CONNECTIONS) |
- |
|
|
|
20.2 (SCREWS, CURRENT-CARRYING PARTS AND CONNECTIONS) |
- |
|
|
|
20.3 (SCREWS, CURRENT-CARRYING PARTS AND CONNECTIONS) |
- |
|
|
|
21.1 (CREEPAGE DISTANCE AND CLEARANCES) |
- |
|
|
|
22.1 (Resistance to Excessive residual Stress and to Rusting ) |
- |
|
|
|
22.1 (Resistance to Excessive residual Stress and to Rusting ) |
- |
|
|
|
22.1 (Resistance to Excessive residual Stress and to Rusting ) |
- |
|
|
|
|
Complete
|
|
- |
- |
269 |
IS 204 : Part 1 (1991) |
Tower bolts - Specification: Part 1 ferrous metals (Fifth Revision) |
- |
-
|
- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
4 -Table 5- i (Ref. Cl 7, Table 3, HR1 grade of IS 1079 : 2017) (Chemical composition - Carbon - IS 228) |
- |
|
|
|
4 -Table 5- i (Ref. Cl 7, Table 3, HR1 grade of IS 1079 : 2017) (Chemical composition - Manganese - IS 228) |
- |
|
|
|
4 -Table 5- i (Ref. Cl 7, Table 3, HR1 grade of IS 1079 : 2017) (Chemical composition - Phosphorus - IS 228) |
- |
|
|
|
4 -Table 5- i (Ref. Cl 7, Table 3, HR1 grade of IS 1079 : 2017) (Chemical composition - Sulphur - IS 228) |
- |
|
|
|
4 -Table 5- ii (Ref. Cl 5, Table 1, E300-C grade of IS 2062 : 2011) (Chemical composition - Silicon - IS 228) |
- |
|
|
|
6.1- Table 1 (Dimension of Barrel tower bolts-1.Size 2.Length of Bolt-A 3.Length of Barrel-B 4.Width of Barrel-C 5.Dia of Bolt-D 6.Length of Socket-E 7.Thickness of mild steel sheet for barrel-F 8.Dia of bore of barrel or socket- G ) |
- |
|
|
|
6.2- Table 2 (Dimension of Sami Barrel Tower Bolts 1.Size 2.Length of Bolt-A 3.Length of Bolt Plate-B 4.Width of Bolt Plate-C 5.Dia of Bolt-D 6.Length of Socket-E 7.Thickness of Bolt Plate or Socket-F 8.Dia of bore of Bolt Plate or socket G ) |
- |
|
|
|
6.2- Table 2 (Dimension of Sami Barrel Tower Bolts-Minimum No. of equally Spaced Screw holes in Bolt Plate and Socket for wood screw no 6) |
- |
|
|
|
|
Partial
|
|
- |
Test facilities are not available for the following:
(1) Finish |
270 |
IS 814 (2004) |
Covered electrodes for manual metal arc welding of carbon and carbon manganese steel - Specification (Sixth Revision) |
- |
-
|
- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
7.1.1 (Diameter of Core Wire) |
- |
|
|
|
7.2.1 (Contact End) |
- |
|
|
|
6 & 8.2 (Carbon- Relevant Parts of IS 228 or any other established instrumental/chemical method) |
- |
|
|
|
6 & 8.2 (Manganese- Relevant Parts of IS 228 or any other established instrumental/chemical method) |
- |
|
|
|
6 & 8.2 (Phosphorous- Relevant Parts of IS 228 or any other established instrumental/chemical method) |
- |
|
|
|
6 & 8.2 (Sulphur- Relevant Parts of IS 228 or any other established instrumental/chemical method) |
- |
|
|
|
7.1.2 (Length of Electrodes) |
- |
|
|
|
7.3 (Concentricity of Flux covering with core wire) |
- |
|
|
|
7.2.2 (Arc striking End) |
- |
|
|
|
|
Partial
|
|
- |
Test facilities are not available for the following:
(1) All weld metal for tensile and impact test (cl 9.1),
(2) running performance test (cl 9.3),
(3) butt weld bend test,
(4) Radiographic test (cl 9.6)
(5) Cu, V, Ti, Al, Cr, Ni, Mo for core wire as per IS 2879 and Mn, Ni, Cr, Mo, V for weld metal
(6) Diffusible Hydrogen Evaluation Test (7) Increased metal recovery test (cl 9.4) |