241 |
IS 636 (2018) |
Non - Percolating flexible fire fighting delivery hose - Specification (Fourth Revision) |
-
|
- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Cl.6.2 (The internal diameter of the hose shall be measured by
a suitable conical plug gauge and shall conform to the
specified diameter with a tolerance of plus 2 and minus
0.0 mm.) |
- |
|
|
|
Cl.6.4 (The average mass of hose per meter of 2 m length,
without couplings attached, shall not be more than that
prescribed in Table 1. For the determination of mass,
sample of the hose shall be conditioned at 27 ± 2°C and
65 ± 5 percent relative humidity for a period of at least
48 h and then shall be weighed under the same conditions.) |
- |
|
|
|
Cl.6.5 (For 30 m length of dry hose without couplings, the coil
diameter shall not exceed 45 cm for Type 1, 50 cm for
Type 2 and 55 cm for Type 3.) |
- |
|
|
|
Cl.6.6 (Each hose length shall be subjected to an internal hydraulic pressure of 23 kgf/cm² in accordance with 8.1 of IS 443
(Part 3) increasing the pressure at the rate not exceeding
10 kgf/cm² per min and maintaining it for 1 min. Within
this 1 min, the hose shall neither develop any leakage or
sweating, nor shall any thread in the jacket break.) |
- |
|
|
|
Cl.6.7 (A test length of hose, 1 m clear of fittings when
subjected to an internal hydraulic pressure in
accordance with 8.3 of IS 443 (Part 3) while increasing
the pressure at the rate not exceeding 10 kgf/cm2 per
min shall not burst or show leakage before a pressure
of 38 kgf/cm2 is reached) |
- |
|
|
|
Cl.6.8 (There shall be no sign of leakage or rupture and no thread in the jacket shall break after retaining the internal hydraulic pressure of 23 kgf/cm2 for 30 seconds.) |
- |
|
|
|
Cl.6.10 (The increase in diameter shall not be more than 10% at an internal hydraulic pressure of 10 kgf/cm2 for 2 minutes.) |
- |
|
|
|
Cl 6.11 (Adhesion (Cl. 6.11.1)) (Rate of separation shall not exceed 25 mm/min 1) Cover) |
- |
|
|
|
Cl 6.11 (Adhesion (Cl. 6.11.1)) (Rate of separation shall not exceed 25 mm/min 2) Jet) |
- |
|
|
|
Cl.6.11 Acccleraled Ageing Test (Cl. 6.11.2) - 1) (After ageing, there shall be no tackiness on the surface of lining or the surface of the cover. ) |
- |
|
|
|
Cl.6.11 Acccleraled Ageing Test (Cl. 6.11.2) - 2) (shall meet the requirements. given in Cl.6.7 (A test length of hose, 1 m clear of fittings when
subjected to an internal hydraulic pressure in
accordance with 8.3 of IS 443 (Part 3) while increasing
the pressure at the rate not exceeding 10 kgf/cm2 per
min shall not burst or show leakage before a pressure
of 38 kgf/cm2 is reached)) |
- |
|
|
|
Cl.6.11 Acccleraled Ageing Test (Cl. 6.11.2) - 3) (Rate of separation shall not exceed 25 mm/min 1) Cover) |
- |
|
|
|
Cl.6.11 Acccleraled Ageing Test (Cl. 6.11.2) - 3) (Rate of separation shall not exceed 25 mm/min 2) Jet) |
- |
|
|
|
Cl.6.5 (For 30 m length of dry hose without couplings, the coil
diameter shall not exceed 45 cm for Type 1, 50 cm for
Type 2 and 55 cm for Type 3.) |
- |
|
|
|
Cl.6.6 (Each hose length shall be subjected to an internal hydraulic pressure of 23 kgf/cm² in accordance with 8.1 of IS 443
(Part 3) increasing the pressure at the rate not exceeding
10 kgf/cm² per min and maintaining it for 1 min. Within
this 1 min, the hose shall neither develop any leakage or
sweating, nor shall any thread in the jacket break.) |
- |
|
|
|
Cl.6.7 (A test length of hose, 1 m clear of fittings when
subjected to an internal hydraulic pressure in
accordance with 8.3 of IS 443 (Part 3) while increasing
the pressure at the rate not exceeding 10 kgf/cm2 per
min shall not burst or show leakage before a pressure
of 38 kgf/cm2 is reached) |
- |
|
|
|
Cl.6.8 (There shall be no sign of leakage or rupture and no thread in the jacket shall break after retaining the internal hydraulic pressure of 23 kgf/cm2 for 30 seconds.) |
- |
|
|
|
Cl.6.9 (The increase in length shall not exceed 6 percent at an internal hydraulic pressure of 10 kgf/cm2 for 2 minutes.) |
- |
|
|
|
Cl.6.3 (Unless specified otherwise, the standard length shall
be 30 m. Unless otherwise specified, a tolerance of ± 2
percent shall be permitted on the length prescribed for
the hose by the purchaser but the total of all lengths of
hose supplied shall be not less than the total quantity
specified by the purchaser.) |
- |
|
|
|
Cl.6.11 Acccleraled Ageing Test (Cl. 6.11.2) - 3) (Rate of separation shall not exceed 25 mm/min 2) Jet) |
- |
|
|
|
Cl.6.11 Acccleraled Ageing Test (Cl. 6.11.2) - 2) (shall meet the requirements. given in Cl.6.7 (A test length of hose, 1 m clear of fittings when
subjected to an internal hydraulic pressure in
accordance with 8.3 of IS 443 (Part 3) while increasing
the pressure at the rate not exceeding 10 kgf/cm2 per
min shall not burst or show leakage before a pressure
of 38 kgf/cm2 is reached)) |
- |
|
|
|
Cl.6.13 (When tested in accordance with Annex D, the amount
of moisture absorbed shall not exceed 0.20 kg/m2 for
Type 2 hoses and 0.02 kg/m2 for Type 3 hoses.) |
- |
|
|
|
Cl.6.14 (When tested by the method described in Annex E, none
of the test samples shall burst at less than 8 s of the
application of the hot cube for Type 2 and 20 s for
Type 3 hose.) |
- |
|
|
|
Cl.6.12 (When determined by the method described in Annex C,
the average number of cycles completed before bursting
of three test pieces, shall not be less than the value
specified in Table 2.) |
- |
|
|
|
|
Partial
|
|
- |
- |
242 |
IS 9968 : Part 1 (1988) |
Specification for elastomer insulatedcables: Part 1 for working voltages up to and including 1100 volts (First Revision) |
-
|
- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
3.1 ( Copper Cooduetor) |
- |
|
|
|
3.2 (Aluminium conductor) |
- |
|
|
|
4.1 (INSULATION : lnsulation for General Service) |
- |
|
|
|
4.2 (INSULATION : Heat Resisting insulation) |
- |
|
|
|
4.3 (INSULATION : Silicone Rubber Insulation) |
- |
|
|
|
5.1 (TAPE : Proofed Tape) |
- |
|
|
|
5.2 (TAPE : 2 Polyethyl_ Terephthalate ( PETP ) Tape or
Plastic: Tape or Any Other SlIIitable Tape ) |
- |
|
|
|
5.3 (TAPE : Giass Tape) |
- |
|
|
|
6.1 (FILLERS : ) |
- |
|
|
|
7.1 (BRAID : Textile Braid) |
- |
|
|
|
7.2 (BRAID : Glass Braid ) |
- |
|
|
|
8.1 (SHEATH : General Service Insulated Cables and Flexible
Cords) |
- |
|
|
|
8.2 (SHEATH :Heat Resisting Insulated Cables) |
- |
|
|
|
9.1 (PresenRtive Compound) |
- |
|
|
|
9.2 (Varnish) |
- |
|
|
|
10 ( Conductor ) |
- |
|
|
|
11 (Separator tape) |
- |
|
|
|
12.2 (Insulation : Thickness of Insufatien) |
- |
|
|
|
12.4 (Insulation : Allplication of Insulation) |
- |
|
|
|
13 (CORE IDENTiFICATlON) |
- |
|
|
|
14 (Tape) |
- |
|
|
|
15 (BRAIDING) |
- |
|
|
|
16 (COMPOUNDING AND VARNISHING) |
- |
|
|
|
17 (LAYING UP OF CORES) |
- |
|
|
|
18 ( Binder tape) |
- |
|
|
|
19.2 (Sheath : Thickness of Sheath) |
- |
|
|
|
19.4 ( Sheath :Colour) |
- |
|
|
|
20 ( Overall diameter) |
- |
|
|
|
21. (b) (Annealing Test (for coper)) |
- |
|
|
|
21. (c) ( Tensile Test (for aluminium)) |
- |
|
|
|
21. (d) ( Wrapping Test (for aluminium)) |
- |
|
|
|
21. (e) (Conductor Resistance ) |
- |
|
|
|
21.1 ( Tensile strength ) |
- |
|
|
|
22.1 ( Elongation) |
- |
|
|
|
21.1 (type test : Ageing In air oven) |
- |
|
|
|
21.1 (type test : Hot set elongation) |
- |
|
|
|
21.1 (type test : Tear resistance ) |
- |
|
|
|
22.2 (type test :Insulauon resistance High voltage (water immersron ) test) |
- |
|
|
|
22.2 (type test : Flammability test
( applicable to cables
finished With SE 3 and
SE 4 sheaths only)
) |
- |
|
|
|
23 (identification) |
- |
|
|
|
|
Partial
|
|
- |
- |
243 |
IS 9857 (1990) |
Welding cables - Specification (First Revision) |
-
|
- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
4 (Conductor : Material ) |
- |
|
|
|
5 (SEPARATOR) |
- |
|
|
|
6 (COVERING) |
- |
|
|
|
7 (CONDUCTOR : CONSTRUCTION ) |
- |
|
|
|
8 (S E P A R A T O R) |
- |
|
|
|
9.1 (C O V E R I N G : Application ) |
- |
|
|
|
9.2 (T h i c k n e s s o f C o v e r i n g) |
- |
|
|
|
9.3 (T o l e r a n c e on Thickness o f C o v e r i n g) |
- |
|
|
|
9.4 (A p p l i c a t i o n of C o v e r i n g) |
- |
|
|
|
9.5 (Colour of C o v e r i n g) |
- |
|
|
|
10.1 a) 1) (Annealing test - IS 10810: Part 1) |
- |
|
|
|
10.1 a) 2) (Conductor resistance tes - IS 10810 : Part 5) |
- |
|
|
|
10.1 c) 1) (Physical tests for
covering : Tensile strength ) |
- |
|
|
|
10.1 c) 1) (Physical tests for
covering : Elongation at break ) |
- |
|
|
|
10.1 c) 2) (Physical tests for
covering - Ageing in Air oven : Tensile strength variation) |
- |
|
|
|
10.1 c) 2) (Physical tests for
covering -Ageing in Air oven : Elongation at break ) |
- |
|
|
|
10.1 c) 2) (Physical tests for
covering - Ageing in Air oven : Tensile strength ) |
- |
|
|
|
10.1 c) 2) (Physical tests for
covering -Ageing in Air oven : Elongation variation at break ) |
- |
|
|
|
10.1 c) 5) (Hot set test ) |
- |
|
|
|
10.1 c) 5) (Permanent set ) |
- |
|
|
|
11.1 (High Voltage Test ( Water Immersion
Test )) |
- |
|
|
|
11.2 (Spark Test) |
- |
|
|
|
11.3 (Static Flexibility Test) |
- |
|
|
|
11.4 (Flammability Test) |
- |
|
|
|
12.1 (Manufacturer's Identification) |
- |
|
|
|
12.2 (Cable Identification) |
- |
|
|
|
12.3 (Cable Code) |
- |
|
|
|
13.1 (Packing ) |
- |
|
|
|
13.2 (Marking) |
- |
|
|
|
14 (CABLE RATINGS) |
- |
|
|
|
15 (VOLTAGE DROP) |
- |
|
|
|
|
Partial
|
|
- |
- |
244 |
IS 9537 : Part 3 (1983) |
Specification for conduits for electrical installations: Part 3 rigid plain conduits of insulating meterials |
-
|
- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
6.1 (Marking) |
- |
|
|
|
6.2 (Durability of Marking as per 6.4 of IS: 9537 (Part 1)-1980) |
- |
|
|
|
6.3 (Standard Mark on Conduit) |
- |
|
|
|
7.1.1 (Maximum and minimum outside diameter of socket) |
- |
|
|
|
7.1.1 Table-2 (Length of Socket end) |
- |
|
|
|
7.1.2 (Maximum and minimum outside diameter of conduit) |
- |
|
|
|
7.2 (Minimum inside diameter of conduit) |
- |
|
|
|
7.3 (Length of conduit) |
- |
|
|
|
7.4 (Unifomity of The wall Thickness) |
- |
|
|
|
8.1 (Construction as per clause 8 of IS: 9537 (Part 1)-1980) |
- |
|
|
|
9.2 (Bending Test i) At Room Temp ii) At Low Temp (-5 ±2°C)) |
- |
|
|
|
9.3 (Compression Test as per caluse 9.3 of IS: 9537 (Part 1)-1980) |
- |
|
|
|
9.4 (Impact Test as per clause 9.4 of IS: 9537 (Part 1)-1980) |
- |
|
|
|
9.5 (Collapse Test as per clause 9.5 of IS: 9537 (Part 1)-1980) |
- |
|
|
|
10 (Resistance to Heat -Ball presure test) |
- |
|
|
|
11 (Resistance to burning as per clause 11 of IS: 9537 (Part 1)-1980) |
- |
|
|
|
12 (Electrical Characteristics-Test for electric strength as per clause 12.1.1 of IS: 9537 (Part 1)-1980) |
- |
|
|
|
12 (Electrical Characteristics-Insulation resistance test as per clause 12.1.2 of IS: 9537 (Part 1)-1980) |
- |
|
|
|
9.3 (Compression Test (after removal of force) as per caluse 9.3.3 of IS: 9537 (Part 1)-1980) |
- |
|
|
|
|
Partial
|
|
- |
- |
245 |
IS 8783 : Part 4 : Sec 3 (1995) |
Winding wires for submersible motors - Specification: Part 4 specification for individual wires: Sec 3 polyester and polypropylene insulated winding wires (First Revision) |
-
|
- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
5.1 (The winding wire shall either be wound on spools / reels conforming to IS 482-1981. or supplied in a coils packed and labelled.) |
- |
|
|
|
6.1 (The winding wire shall carry following information marked on the lable on spool / reel / coil;) |
- |
|
|
|
6.1 (a) Reference to this Indian Standard;) |
- |
|
|
|
6.1 (b) Manufacturer's name,brand name or trade-mark;) |
- |
|
|
|
6.1 (c) Size of conductor / maximum overall diameter,) |
- |
|
|
|
6.1 (d) Length of conductor on spool / reel /coil;) |
- |
|
|
|
6.1 (e) Number of lengths onspool / reel / coil (if more than one);) |
- |
|
|
|
6.1 (f) Country of Manufacturer) |
- |
|
|
|
6.1 (g) Year of Manufacture.) |
- |
|
|
|
6.2 (BIS Certification Mark) |
- |
|
|
|
4 (i) Material) |
- |
|
|
|
5 (ii) Diameter [mm] Seperate wire:) |
- |
|
|
|
5 (ii) Diameter [mm] Wire taken from cable:) |
- |
|
|
|
5 (iii) Annealing test [Percentage] on Seperate wire:) |
- |
|
|
|
5 (iii) Annealing test [Percentage] on Wire taken from cable:) |
- |
|
|
|
5 (d) Resistance test [Ohm/km corrected to 20°c) |
- |
|
|
|
4.1, table 1 & 2 (a) Thickness of Polyster (mm)) |
- |
|
|
|
4.1, table 1 & 3 (b) Thickness of Polypropylene (mm)) |
- |
|
|
|
4.1, table 1 & 4 (c) Total thickness of Insulation(mm)) |
- |
|
|
|
4.2 (Application of insulation) |
- |
|
|
|
4.3 (Colour of Insuation) |
- |
|
|
|
4.4 (Overall diameter (mm)) |
- |
|
|
|
4 (Before ageing Tensile strength [N/mm²]) |
- |
|
|
|
4 (Before ageing Elongation at break [Percentage]) |
- |
|
|
|
4 (After ageing Tensile strength [N/mm²]) |
- |
|
|
|
4 (Variation on tensile strangth [Percentage]) |
- |
|
|
|
4 (After ageing Elongation at break [Percentage]) |
- |
|
|
|
4 (Variation on elongation at break [Percentage]) |
- |
|
|
|
4 (Shrinkage test [Percentage]) |
- |
|
|
|
4 (After Shrinkage Cracks found.) |
- |
|
|
|
4.1 (Water absorption test [Gravimetric] [mg/cm²]) |
- |
|
|
|
4.5 (High Voltage test [Water Immersion test] 3 KV for 1 Minute) |
- |
|
|
|
5 (The winding wire shall either be wound on spools / reels conforming to IS 482-1981. or supplied in a coils packed and labelled.) |
- |
|
|
|
6 (The winding wire shall carry following information marked on the lable on spool / reel / coil;) |
- |
|
|
|
6 (a) Reference to this Indian Standard;) |
- |
|
|
|
6 (b) Manufacturer's name,brand name or trade-mark;) |
- |
|
|
|
6 (c) Size of conductor / maximum overall diameter,) |
- |
|
|
|
6 (d) Length of conductor on spool / reel /coil;) |
- |
|
|
|
6 (e) Number of lengths onspool / reel / coil (if more than one);) |
- |
|
|
|
6 (f) Country of Manufacturer Marking) |
- |
|
|
|
6 (g) Year of Manufacture.) |
- |
|
|
|
6.2 (BIS Certification Mark) |
- |
|
|
|
|
Partial
|
|
- |
- |
246 |
IS 8783 : Part 4 : Sec 1 (1995) |
Winding wires for submersible motors - Specification: Part 4 specification for indmdual wires: Sec 1 HR PVC insulated wires (First Revision) |
-
|
- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Cl.3.1 (Conductor) |
- |
|
|
|
Cl.4 (Material) |
- |
|
|
|
Cl.5.1.1 (Dimensions) |
- |
|
|
|
Cl. 6 (Annealing Test) |
- |
|
|
|
Cl 6 (Resistance Test) |
- |
|
|
|
Cl 4.1.2 (Visual examination) |
- |
|
|
|
Cl.3.2 (Dielectric Material ) |
- |
|
|
|
Cl. 4 Table 1of IS: 8783 (part 2) (Volume resistivity) |
- |
|
|
|
Cl. 4 Table 1of IS: 8783 (part 2) (Volume resistivity) |
- |
|
|
|
Cl. 4 Table 1of IS: 8783 (part 2) (Tensile strength ) |
- |
|
|
|
Cl. 4 Table 1of IS: 8783 (part 2) (Elongation) |
- |
|
|
|
Cl. 4 Table 1of IS: 8783 (part 2) (Tensile Strength) |
- |
|
|
|
Cl. 4 Table 1of IS: 8783 (part 2) (Variation) |
- |
|
|
|
Cl. 4 Table 1of IS: 8783 (part 2) (Elongation at Break ) |
- |
|
|
|
Cl. 4 Table 1of IS: 8783 (part 2) (Variation) |
- |
|
|
|
Cl. 4 Table 1of IS: 8783 (part 2) (Shrinkage test ) |
- |
|
|
|
Cl. 4 Table 1of IS: 8783 (part 2) (Shrinkage test ) |
- |
|
|
|
Cl. 4 Table 1of IS: 8783 (part 2) (Water absorption (Gravimetric) ) |
- |
|
|
|
Cl. 4 Table 1of IS: 8783 (part 2) (Hot deformation Test ) |
- |
|
|
|
Cl. 4 Table 1of IS: 8783 (part 2) (Heat shock Test ) |
- |
|
|
|
Cl.4.1 (Insulation ) |
- |
|
|
|
Cl.4.2 (Application) |
- |
|
|
|
Cl.4.3 (Colour) |
- |
|
|
|
Cl.4.4 (Overall Diameter) |
- |
|
|
|
Cl.4.5 (Finish) |
- |
|
|
|
Cl.4.6 (High Voltage Test Water Immersion ) |
- |
|
|
|
|
Partial
|
|
- |
- |
247 |
IS 7098 : Part 1 (1988) |
Specification for crosslinked polyethylene insulated pvc sheathed cables: Part 1 for working voltages up to and including 1100 volts (First Revision) |
-
|
- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
3 (CONDUCTOR: MATERIALS) |
- |
|
|
|
4 (INSULATION : MATERIALS) |
- |
|
|
|
5.1 (FILLER AND INNER SHEATH) |
- |
|
|
|
5.2 (FILLER AND INNER SHEATH) |
- |
|
|
|
6 (ARMOURING) |
- |
|
|
|
7 (OUTER SHEATH) |
- |
|
|
|
8.1 (CONDUCTOR: CONSTRUCTION) |
- |
|
|
|
8.2 (PROTECTIVE BARRIER) |
- |
|
|
|
8.3 (SIZE OF NEUTRAL CONDUCTOR) |
- |
|
|
|
9.1 (Insulation Applied by extrusicn) |
- |
|
|
|
9.2 (Thickness of Insulation - Average) |
- |
|
|
|
9.3 (Thickness of Insulation - Minimum) |
- |
|
|
|
9.4 (Application of Insulation) |
- |
|
|
|
10.1 (Core Identification) |
- |
|
|
|
10.2 (Core Identification- Neutral) |
- |
|
|
|
10.3 (Core Identification by number ) |
- |
|
|
|
10.4 (Core Identification by number - Neutral ) |
- |
|
|
|
11 (LAVING UP OF CORES) |
- |
|
|
|
12.1 & 12.2 (Inner sheath : Application) |
- |
|
|
|
12.3 (Thickness of Inner Sheath) |
- |
|
|
|
13.1 (Armouring: Application) |
- |
|
|
|
13.1.2 (Armouring: Coverage ) |
- |
|
|
|
13.1.3 (Armouring: Direction of Lay ) |
- |
|
|
|
13.2 (Type of armour ) |
- |
|
|
|
13.3 (Armouring : Dimensions -Wire Diameter) |
- |
|
|
|
13.4 (Armour: Joint) |
- |
|
|
|
13.5 (Armouring : Resistance Test) |
- |
|
|
|
13.6 a) (ARMOURING: Tensile Strength) |
- |
|
|
|
13.6 b) (ARMOURING: Elongation ) |
- |
|
|
|
13.6 c) (ARMOURING: Torsion Test (For round wire ) ) |
- |
|
|
|
13.6 d) (ARMOURING: Winding Test(For formed wire)) |
- |
|
|
|
13.6 e) (ARMOURING: Uniformity of zinc coating) |
- |
|
|
|
13.6 f) (ARMOURING: Mass of zinc coating ) |
- |
|
|
|
13.6 g) (ARMOURING: Resistivity) |
- |
|
|
|
14.1 (Outer Sheath : Application) |
- |
|
|
|
14.2 (Colour of outer sheath) |
- |
|
|
|
14.3 (Thickness of outer sheath - AVERAGE) |
- |
|
|
|
14.3 (Thickness of outer sheath - minimum) |
- |
|
|
|
15.1 a) i) (Annealing Test ( For copper wire ) ) |
- |
|
|
|
15.1 a) ii) (Tensile test (for aluminium) - Before stranding ) |
- |
|
|
|
15.1 a) ii) (Tensile test (for aluminium) - After stranding ) |
- |
|
|
|
15.1 a) iii) (Wrapping test (for aluminium)) |
- |
|
|
|
15.1 a) iv) (Resistance test - Main conductor) |
- |
|
|
|
15.1 a) iv) (Resistance test - Neutral conductor) |
- |
|
|
|
15.1 d) i) (Phyaical tests for insulation : Tensile Test) |
- |
|
|
|
15.1 d) i) (Phyaical tests for insulation : Elongation) |
- |
|
|
|
15.1 d) ii) (Phyaical tests for insulation - Ageing in air Oven : Tensile Variation ) |
- |
|
|
|
15.1 d) ii) (Phyaical tests for insulation- Ageing in air oven : Elongation Variation ) |
- |
|
|
|
15.1 d) iii) (Phyaical tests for insulation : Hot set ) |
- |
|
|
|
15.1 d) iii) (Phyaical tests for insulation : Permanent set ) |
- |
|
|
|
15.1 d) iv) (Phyaical tests for insulation : Shrinkage ) |
- |
|
|
|
15.1 d) iv) (Phyaical tests for insulation : Shrinkage - Crack observed ) |
- |
|
|
|
15.1 d) v) (Insulation: Waterabsorption(gravimetric)) |
- |
|
|
|
15.1 e) i) (Physical tests for outer sheath : Tensile stregth) |
- |
|
|
|
15.1 e) i) (Physical tests for outer sheath : Elongation) |
- |
|
|
|
15.1 e) ii) (Physical tests for outer sheath- Ageing in air oven : Tensile stregth ) |
- |
|
|
|
15.1 e) ii) (Physical tests for outer sheath -Ageing in air oven : Elongation ) |
- |
|
|
|
15.1 e) ii) (Physical tests for outer sheath- Ageing in air oven : Tensile stregth Variation ) |
- |
|
|
|
15.1 e) ii) (Physical tests for outer sheath -Ageing in air oven : Elongation ) |
- |
|
|
|
15.1 e) iii) (Sheath: Loss of mass in air oven) |
- |
|
|
|
15.1 e) iv) (Phyaical tests for Sheath : Shrinkage ) |
- |
|
|
|
15.1 e) iv) (Phyaical tests for Sheath : Shrinkage - Crack observed ) |
- |
|
|
|
15.1 e) v) (Sheath : Hot deformation) |
- |
|
|
|
15.1 e) vi) (Sheath : Heat shock test) |
- |
|
|
|
15.1 e) vii) (Sheath : Thermalstability) |
- |
|
|
|
15.1 f) (INSULATION RESISTANCE TEST : Volume resistivity ) |
- |
|
|
|
16.2 (HIGH VOLTAGE TEST ) |
- |
|
|
|
16.3 (FLAMMABILITY TEST : Period of Burning ) |
- |
|
|
|
16.3 (FLAMMABILITY TEST : Unaffected length ) |
- |
|
|
|
17.1 (Manufacturer'. ldeadentificatioa) |
- |
|
|
|
17.2 (cable Indentification ) |
- |
|
|
|
17.3 (cable Code ) |
- |
|
|
|
15.1 e) ii) (Physical tests for outer sheath -Ageing in air oven : Elongation Variation ) |
- |
|
|
|
|
Partial
|
|
- |
- |
248 |
IS 4250 (1980) |
Specification for domestic electric food - Mixers (Liquidizers And Grinders) (First Revision) |
-
|
- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
6 (Classification- IS 302-1 ) |
- |
|
|
|
6 (Classification- IS 302-1) |
- |
|
|
|
7.1 (Marking- IS 302-1) |
- |
|
|
|
7.1 (Marking- IS 302-1) |
- |
|
|
|
7.1 (Marking- IS 302-1) |
- |
|
|
|
7.1 (Marking- IS 302-1) |
- |
|
|
|
7.1 (Marking- IS 302-1) |
- |
|
|
|
7.1 (Marking- IS 302-1) |
- |
|
|
|
7.1 (Marking- IS 302-1) |
- |
|
|
|
7.1 (Marking- IS 302-1) |
- |
|
|
|
7.1 (Marking- IS 302-1) |
- |
|
|
|
7.1 (Marking- IS 302-1) |
- |
|
|
|
7.1 (Marking- IS 302-1) |
- |
|
|
|
7.1 (Marking- IS 302-1) |
- |
|
|
|
7.1 (Marking- IS 302-1) |
- |
|
|
|
7.2 (Marking) |
- |
|
|
|
7.1 (Marking- IS 302-1) |
- |
|
|
|
7.1 (Marking- IS 302-1) |
- |
|
|
|
7.1 (Marking- IS 302-1) |
- |
|
|
|
7.4 (Marking) |
- |
|
|
|
7.5 (Marking) |
- |
|
|
|
7.6 (Marking) |
- |
|
|
|
8 ( Protection Against Electric Shock, IS 302-1) |
- |
|
|
|
9 (Starting, IS 302-1) |
- |
|
|
|
10 (Power Input and Current, IS 302-1) |
- |
|
|
|
11 (Heating, IS 302-1) |
- |
|
|
|
11 (Heating, IS 302-1) |
- |
|
|
|
11 (Heating, IS 302-1) |
- |
|
|
|
11 (Heating, IS 302-1) |
- |
|
|
|
11 (Heating, IS 302-1) |
- |
|
|
|
13 (Electrical Insulation and Leakage Current at Operating Temperature: Leakage current, IS 302-1) |
- |
|
|
|
13 (Electrical Insulation and Leakage Current at Operating Temperature: High Voltage, IS 302-1) |
- |
|
|
|
15.1 (Moisture Resistance, IS 302-1) |
- |
|
|
|
15.2 (Moisture Resistance-Spillage test) |
- |
|
|
|
15 (Moisture Resistance, IS 302-1) |
- |
|
|
|
16 (Electrical Insulation and Leakage Current at Operating Temperature: Leakage current, IS 302-1) |
- |
|
|
|
16 (Electrical Insulation and Leakage Current at Operating Temperature: High Voltage, IS 302-1) |
- |
|
|
|
19 (Abnormal Operation, IS 302-1) |
- |
|
|
|
19 (Abnormal Operation, IS 302-1) |
- |
|
|
|
19 (Abnormal Operation, IS 302-1) |
- |
|
|
|
19 (Abnormal Operation, IS 302-1) |
- |
|
|
|
20 (Stability & Mechanical Hazards, IS 302-1) |
- |
|
|
|
20 (Stability & Mechanical Hazards, IS 302-1) |
- |
|
|
|
21 (Mechanical Strength, IS 302-1) |
- |
|
|
|
21 (Mechanical Strength, IS 302-1) |
- |
|
|
|
22.1 (Construction, IS 302-1) |
- |
|
|
|
22.2 (Construction) |
- |
|
|
|
22.3 (Construction) |
- |
|
|
|
22.4 (Construction) |
- |
|
|
|
22.5 (Construction) |
- |
|
|
|
22.6 (Construction) |
- |
|
|
|
22.8 (Construction) |
- |
|
|
|
22.9 (Construction) |
- |
|
|
|
22.1 (Construction) |
- |
|
|
|
23 (Internal Wiring, IS 302-1) |
- |
|
|
|
23 (Internal Wiring, IS 302-1) |
- |
|
|
|
23 (Internal Wiring, IS 302-1) |
- |
|
|
|
23 (Internal Wiring, IS 302-1) |
- |
|
|
|
23 (Internal Wiring, IS 302-1) |
- |
|
|
|
23 (Internal Wiring, IS 302-1) |
- |
|
|
|
23 (Internal Wiring, IS 302-1) |
- |
|
|
|
23 (Internal Wiring, IS 302-1) |
- |
|
|
|
23 (Internal Wiring, IS 302-1) |
- |
|
|
|
23 (Internal Wiring, IS 302-1) |
- |
|
|
|
24.1 (Components, IS 302-1) |
- |
|
|
|
24.1 (Components, IS 302-1) |
- |
|
|
|
24.1 (Components, IS 302-1) |
- |
|
|
|
24.2 (Components) |
- |
|
|
|
24.4 (Components) |
- |
|
|
|
24.7 (Components) |
- |
|
|
|
24.8 (Components) |
- |
|
|
|
24.9 (Components) |
- |
|
|
|
25 (Supply Connection and External Flexible Cords, IS 302-1) |
- |
|
|
|
25 (Supply Connection and External Flexible Cords, IS 302-1) |
- |
|
|
|
25 (Supply Connection and External Flexible Cords, IS 302-1) |
- |
|
|
|
25 (Supply Connection and External Flexible Cords, IS 302-1) |
- |
|
|
|
25 (Supply Connection and External Flexible Cords, IS 302-1) |
- |
|
|
|
25 (Supply Connection and External Flexible Cords, IS 302-1) |
- |
|
|
|
25 (Supply Connection and External Flexible Cords, IS 302-1) |
- |
|
|
|
25 (Supply Connection and External Flexible Cords, IS 302-1) |
- |
|
|
|
25 (Supply Connection and External Flexible Cords, IS 302-1) |
- |
|
|
|
25 (Supply Connection and External Flexible Cords, IS 302-1) |
- |
|
|
|
25 (Supply Connection and External Flexible Cords, IS 302-1) |
- |
|
|
|
25 (Supply Connection and External Flexible Cords, IS 302-1) |
- |
|
|
|
25 (Supply Connection and External Flexible Cords, IS 302-1) |
- |
|
|
|
25 (Supply Connection and External Flexible Cords, IS 302-1) |
- |
|
|
|
25 (Supply Connection and External Flexible Cords, IS 302-1) |
- |
|
|
|
25 (Supply Connection and External Flexible Cords, IS 302-1) |
- |
|
|
|
25 (Supply Connection and External Flexible Cords, IS 302-1) |
- |
|
|
|
25 (Supply Connection and External Flexible Cords, IS 302-1) |
- |
|
|
|
25 (Supply Connection and External Flexible Cords, IS 302-1) |
- |
|
|
|
25 (Supply Connection and External Flexible Cords, IS 302-1) |
- |
|
|
|
25 (Supply Connection and External Flexible Cords, IS 302-1) |
- |
|
|
|
25 (Supply Connection and External Flexible Cords, IS 302-1) |
- |
|
|
|
26 (Terminals for External Conductors, IS 302-1) |
- |
|
|
|
27 (Provision for Earthing, IS 302-1) |
- |
|
|
|
27 (Provision for Earthing, IS 302-1) |
- |
|
|
|
27 (Provision for Earthing, IS 302-1) |
- |
|
|
|
27 (Provision for Earthing, IS 302-1) |
- |
|
|
|
27 (Provision for Earthing, IS 302-1) |
- |
|
|
|
28 (Screws & Connections, IS 302-1) |
- |
|
|
|
29 (Clearances and Distances through Insulation, IS 302-1) |
- |
|
|
|
29 (Clearances and Distances through Insulation, IS 302-1) |
- |
|
|
|
30 (Resistance to Heat, Fire, Tracking, IS 302-1) |
- |
|
|
|
30 (Resistance to Heat, Fire, Tracking, IS 302-1) |
- |
|
|
|
31 (Resistance of Rusting, IS 302-1) |
- |
|
|
|
34.2 (Operational tests- Grinding coffee (for machines which have a dry grinding arrangement)) |
- |
|
|
|
34.2 (Operational tests- Grinding coffee (for machines which have a dry grinding arrangement)) |
- |
|
|
|
34.2 (Operational tests- Grinding coffee (for machines which have a dry grinding arrangement)) |
- |
|
|
|
34.3 (Whisking egg whites ) |
- |
|
|
|
34.4 (IDLI batter-Grinding of black gram) |
- |
|
|
|
34.4 (IDLI batter-Grinding of rice) |
- |
|
|
|
34.4 (IDLI batter-Grinding of rice) |
- |
|
|
|
34.4 (IDLI batter-Grinding of rice) |
- |
|
|
|
34.5.1 (a) (Operational test for juicers ) |
- |
|
|
|
34.5.1 (b) (Operational test for juicers ) |
- |
|
|
|
34.5.2 (Operational test for juicers ) |
- |
|
|
|
35 (Temperature withstand test for bowl) |
- |
|
|
|
36 (Test for controls ) |
- |
|
|
|
37 (Strength of Assembly ) |
- |
|
|
|
37 (Strength of Assembly ) |
- |
|
|
|
|
Partial
|
|
- |
- |
249 |
IS 3975 (1999) |
Low carbon galvanized steel wires, formed wires and tapes for armouring of cables - Specification (Third Revision) |
-
|
- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Clause 6.1, Table-1 (Sulphur) |
- |
|
|
|
Clause 6.1, Table-1 (Phosphorus) |
- |
|
|
|
9.1 (Galvanizing Requirements ) |
- |
|
|
|
14 (a) (Marking) |
- |
|
|
|
14 (b) (Marking) |
- |
|
|
|
14 (c) (Marking) |
- |
|
|
|
14 (d) (Marking) |
- |
|
|
|
14 (e) (Marking) |
- |
|
|
|
14 (f) (Marking) |
- |
|
|
|
14 (g) (Marking) |
- |
|
|
|
14.2 (Marking) |
- |
|
|
|
7 (Dimensions) |
- |
|
|
|
7 (Dimensions) |
- |
|
|
|
7 (Dimensions) |
- |
|
|
|
7 (Dimensions) |
- |
|
|
|
7 (Dimensions) |
- |
|
|
|
11 (Freedom from defects) |
- |
|
|
|
9.1 (Galvanizing Requirements ) |
- |
|
|
|
9.2 (Galvanizing Requirements ) |
- |
|
|
|
9.3 (Galvanizing Requirements ) |
- |
|
|
|
8.1 (Mechanical Properties (as per table 5 of IS 1608)) |
- |
|
|
|
8.1 (Mechanical Properties (as per table 5 of IS 1608)) |
- |
|
|
|
8.2 (Mechanical Properties (as per IS 1717)) |
- |
|
|
|
8.3 (Mechanical Properties (as per IS 1755)) |
- |
|
|
|
8.4 (Mechanical Properties (as per IS 10810(Part- 42))) |
- |
|
|
|
14 (Marking) |
- |
|
|
|
14 (b) (Marking) |
- |
|
|
|
|
Partial
|
|
- |
- |
250 |
IS 2465 (1984) |
Specification for cables for motor vehicles (Second Revision) |
-
|
- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
7.1 (Insulation) |
- |
|
|
|
7.3 (Insulation) |
- |
|
|
|
8 (Core Identification) |
- |
|
|
|
9 (Laying up of cores) |
- |
|
|
|
10.1.1 (Sheathing ) |
- |
|
|
|
10.2 (Sheathing ) |
- |
|
|
|
3 & 6 (Flexibility class) |
- |
|
|
|
3 & 6 (Construction) |
- |
|
|
|
3 & 6 (Diameter of wire(mm)) |
- |
|
|
|
3 & 6 (Annealing test) |
- |
|
|
|
3 & 6 (Persulphate Test) |
- |
|
|
|
3 & 6 (Conductor resistance Test (ohm/km at 20˚c)) |
- |
|
|
|
7.2, 10.3, 11 (Dimensions & thickness ) |
- |
|
|
|
7.2, 10.3, 11 (Dimensions & thickness ) |
- |
|
|
|
7.2, 10.3, 11 (Overall Dimension (mm)) |
- |
|
|
|
4.2 & 12.1 (Without Ageing For Insulation
Tensile Strength (N/mm²)) |
- |
|
|
|
4.2 & 12.1, (f), 1 (elongation at break (N/mm²)) |
- |
|
|
|
4.2 & 12.1, (f), 1 (Tensile Strength at break (N/mm²)) |
- |
|
|
|
4.2 & 12.1, (e), 1 (elongation test at break) |
- |
|
|
|
4.2 & 12.1, (e), 1 (Tensile strength at break) |
- |
|
|
|
4.2 & 12.1, (f), 2 (Ageing in air oven) |
- |
|
|
|
4.2 & 12.1, (f), 3 (Ageing in oxygen bomb) |
- |
|
|
|
4.2 & 12.1, (e), 2 (After Ageing in air oven) |
- |
|
|
|
4.2 & 12.1, (e), 3 (Loss of mass test (mg/cm²) of Insulation) |
- |
|
|
|
4.2 & 12.1, (e), 3 (Loss of mass test (mg/cm²) of Sheath) |
- |
|
|
|
4.2 & 12.1, (e), 4 (Hot deformation test (%) of Insulation) |
- |
|
|
|
14 (High Voltage Test) |
- |
|
|
|
15 (SPARK TEST FOR SINGLE CORE GENERAL WIRING CABLES) |
- |
|
|
|
18.1 (EFFECT OF HEAT ON FLEXIBILITY FOR IGNITION CABLES) |
- |
|
|
|
19.2 (EFFECT OF OIL ON IGNITION CABLES) |
- |
|
|
|
20.3 (EFFECT OF LUBRICATING OIL) |
- |
|
|
|
20.3 (EFFECT OF LUBRICATING OIL) |
- |
|
|
|
20.3 (EFFECT OF BRAKE FLUID) |
- |
|
|
|
20.3 (EFFECT OF BRAKE FLUID) |
- |
|
|
|
20.3 (EFFECT OF DIESEL) |
- |
|
|
|
20.3 (EFFECT OF DIESEL) |
- |
|
|
|
20.3 (Wrapping test) |
- |
|
|
|
21.1 (EFFECT OF COOLING ON FLEXIBILITY) |
- |
|
|
|
21.2 (EFFECT OF COOLING ON FLEXIBILITY) |
- |
|
|
|
21.2 (EFFECT OF COOLING ON FLEXIBILITY) |
- |
|
|
|
22.1 (FLAMMABILITY TEST) |
- |
|
|
|
22.1 (FLAMMABILITY TEST) |
- |
|
|
|
23.1 (Manufacturer's Identification) |
- |
|
|
|
23.1 (Manufacturer's Identification) |
- |
|
|
|
24.1 (PACKING AND MARKING) |
- |
|
|
|
24.2 (PACKING AND MARKING) |
- |
|
|
|
24.2.1 (PACKING AND MARKING) |
- |
|
|
|
4.2 & 12.1, (e), 4 (Hot deformation test (%) of Sheath) |
- |
|
|
|
4.2 & 12.1, (e), 5 (Heat Shock Test of Insulation) |
- |
|
|
|
4.2 & 12.1, (e), 5 (Heat Shock Test of Sheath) |
- |
|
|
|
4.2 & 12.1, (e), 6 (Shrinkage Test (%) of Insulation) |
- |
|
|
|
4.2 & 12.1, (e), 6 (Shrinkage Test (%) of Sheath) |
- |
|
|
|
|
Partial
|
|
- |
- |
251 |
IS 1293 (2019) |
Plugs and socket - Outlets of rated Voltage up to and including 250 Volts and rated current up to and including 16 amperes - Specification (Third Revision) |
-
|
- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
6 (Ratings) |
- |
|
|
|
7.1.1 (Accessories Classification) |
- |
|
|
|
7.1.2 (Accessories Classification) |
- |
|
|
|
7.1.3 (Accessories Classification) |
- |
|
|
|
7.1.4 (Accessories Classification) |
- |
|
|
|
7.1.5 (Accessories Classification) |
- |
|
|
|
7.2.1 (Socket-Outlets Classification) |
- |
|
|
|
7.2.2 (Socket-Outlets Classification) |
- |
|
|
|
7.2.3 (Socket-Outlets Classification) |
- |
|
|
|
7.2.4 (Socket-Outlets Classification) |
- |
|
|
|
7.3 (Plug Classification) |
- |
|
|
|
8.1 (MARKING) |
- |
|
|
|
8.8 (MARKING) |
- |
|
|
|
8.9 (MARKING) |
- |
|
|
|
9.1 (CHECKING OF DIMENSIONS) |
- |
|
|
|
9.2 (CHECKING OF DIMENSIONS) |
- |
|
|
|
10.1 (PROTECTION AGAINST ELECTRIC SHOCK) |
- |
|
|
|
10.1 (PROTECTION AGAINST ELECTRIC SHOCK) |
- |
|
|
|
10.3 (PROTECTION AGAINST ELECTRIC SHOCK) |
- |
|
|
|
10.4 (PROTECTION AGAINST ELECTRIC SHOCK) |
- |
|
|
|
10.5 (PROTECTION AGAINST ELECTRIC SHOCK) |
- |
|
|
|
10.6 (PROTECTION AGAINST ELECTRIC SHOCK) |
- |
|
|
|
10.7 (PROTECTION AGAINST ELECTRIC SHOCK) |
- |
|
|
|
11.1 (PROVISIONS FOR EARTHING) |
- |
|
|
|
11.2 (PROVISIONS FOR EARTHING) |
- |
|
|
|
11.3 (PROVISIONS FOR EARTHING) |
- |
|
|
|
11.4 (PROVISIONS FOR EARTHING) |
- |
|
|
|
11.5 (PROVISIONS FOR EARTHING) |
- |
|
|
|
11.6 (PROVISIONS FOR EARTHING) |
- |
|
|
|
12.1.1 (TERMINALS) |
- |
|
|
|
12.1.2 (TERMINALS) |
- |
|
|
|
12.2.1 (TERMINALS) |
- |
|
|
|
12.2.2 (TERMINALS) |
- |
|
|
|
12.2.3 (TERMINALS) |
- |
|
|
|
12.2.4 (TERMINALS) |
- |
|
|
|
12.2.5 (TERMINALS) |
- |
|
|
|
12.2.6 (TERMINALS) |
- |
|
|
|
12.2.7 (TERMINALS) |
- |
|
|
|
12.2.8 (TERMINALS) |
- |
|
|
|
12.2.9 (TERMINALS) |
- |
|
|
|
12.2.10 (TERMINALS) |
- |
|
|
|
12.2.11 (TERMINALS) |
- |
|
|
|
12.3.1 (TERMINALS) |
- |
|
|
|
12.3.2 (TERMINALS) |
- |
|
|
|
12.3.3 (TERMINALS) |
- |
|
|
|
12.3.4 (TERMINALS) |
- |
|
|
|
12.3.5 (TERMINALS) |
- |
|
|
|
12.3.6 (TERMINALS) |
- |
|
|
|
12.3.7 (TERMINALS) |
- |
|
|
|
12.3.8 (TERMINALS) |
- |
|
|
|
12.3.9 (TERMINALS) |
- |
|
|
|
12.3.10 (TERMINALS) |
- |
|
|
|
12.3.11 (TERMINALS) |
- |
|
|
|
12.3.12 (TERMINALS) |
- |
|
|
|
13.1 (CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
|
|
|
13.2 (CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
|
|
|
13.3 (CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
|
|
|
13.4 (CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
|
|
|
13.5 (CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
|
|
|
13.6 (CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
|
|
|
13.7 (CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
|
|
|
13.8 (CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
|
|
|
13.9 (CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
|
|
|
13.1 (CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
|
|
|
13.11 (CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
|
|
|
13.12 (CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
|
|
|
13.13 (CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
|
|
|
13.14 (CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
|
|
|
13.15 (CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
|
|
|
13.16 (CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
|
|
|
13.17 (CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
|
|
|
13.18 (CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
|
|
|
13.19 (CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
|
|
|
13.2 (CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
|
|
|
13.21 (CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
|
|
|
13.22 (CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
|
|
|
13.23 (CONSTRUCTIONS OF FIXED SOCKETOUTLETS) |
- |
|
|
|
14.1 (CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
|
|
|
14.2 (CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
|
|
|
14.3 (CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
|
|
|
14.4 (CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
|
|
|
14.5 (CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
|
|
|
14.6 (CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
|
|
|
14.7 (CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
|
|
|
14.8 (CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
|
|
|
14.9 (CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
|
|
|
14.1 (CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
|
|
|
14.11 (CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
|
|
|
14.12 (CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
|
|
|
14.13 (CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
|
|
|
14.14 (CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
|
|
|
14.15 (CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
|
|
|
14.16 (CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
|
|
|
14.17 (CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
|
|
|
14.18 (CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
|
|
|
14.19 (CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
|
|
|
14.2 (CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
|
|
|
14.21 (CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
|
|
|
14.6 (CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
|
|
|
14.23 (CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
|
|
|
14.23.1 (CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
|
|
|
14.23.2 (CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
|
|
|
14.24 (CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
|
|
|
14.25 (CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
|
|
|
14.26 (CONSTRUCTION OF PLUGS AND PORTABLE SOCKET-OUTLET) |
- |
|
|
|
15 (INTERLOCKED SOCKET-OUTLETS) |
- |
|
|
|
16.1 (RESISTANCE TO AGEING,) |
- |
|
|
|
16.2 (RESISTANCE TO HARMFUL INGRESS OF WATER AND TO HUMIDITY) |
- |
|
|
|
16.3 (Resistance to Humidity) |
- |
|
|
|
17.1 (INSULATION RESISTANCE AND ELECTRIC STRENGTH) |
- |
|
|
|
17.2 (INSULATION RESISTANCE AND ELECTRIC STRENGTH) |
- |
|
|
|
17.3 (INSULATION RESISTANCE AND ELECTRIC STRENGTH) |
- |
|
|
|
18 (OPERATION OF EARTHING CONTACTS) |
- |
|
|
|
19 (TEMPERATURE RISE) |
- |
|
|
|
20 (BREAKING CAPACITY) |
- |
|
|
|
21 (NORMAL OPERATION) |
- |
|
|
|
21 (NORMAL OPERATION) |
- |
|
|
|
21 (NORMAL OPERATION) |
- |
|
|
|
21 (NORMAL OPERATION) |
- |
|
|
|
22.1 (Verification of the Maximum Withdrawal Force) |
- |
|
|
|
22.2 (Verification of Minimum Withdrawal Force) |
- |
|
|
|
23.1 (FLEXIBLE CABLES AND THEIR CONNECTION) |
- |
|
|
|
23.1 (FLEXIBLE CABLES AND THEIR CONNECTION) |
- |
|
|
|
23.3 (FLEXIBLE CABLES AND THEIR CONNECTION) |
- |
|
|
|
23.4 (FLEXIBLE CABLES AND THEIR CONNECTION) |
- |
|
|
|
24.1 (MECHANICAL STRENGTH
For all kinds of fixed socket-outlets
) |
- |
|
|
|
24.1 (MECHANICAL STRENGTH
For portable multiple and combined socket outlets
with enclosures, covers or bodies other than thermoplastic or elastomeric material) |
- |
|
|
|
24.1 (MECHANICAL STRENGTH
For surface mounting boxes) |
- |
|
|
|
24.2 (MECHANICAL STRENGTH
For portable single socket-outlets:
1) with enclosures, covers or bodies other than thermoplastic or elastomeric material) |
- |
|
|
|
24.2 (MECHANICAL STRENGTH
For portable multiple and combined socket outlets:
1) with enclosures, covers and bodies of elastomeric or thermoplastic material) |
- |
|
|
|
24.2 (MECHANICAL STRENGTH
For plug
1) with enclosures, covers and bodies other than elastomeric or thermoplastic material) |
- |
|
|
|
24.2 (MECHANICAL STRENGTH
For plug
1) with enclosures, covers and bodies of elastomeric or thermoplastic material) |
- |
|
|
|
24.3 (MECHANICAL STRENGTH
for fixed socket-outlets with a main part intended to be mounted directly on a surface) |
- |
|
|
|
24.4 (MECHANICAL STRENGTH
For portable single socket-outlets:
1) with enclosures, covers or bodies of thermoplastic or elastomeric material) |
- |
|
|
|
24.4 (MECHANICAL STRENGTH
For portable multiple and combined socket outlets:
1) with enclosures, covers and bodies of elastomeric or thermoplastic material) |
- |
|
|
|
24.4 (MECHANICAL STRENGTH
For Plug
1) with enclosures, covers and bodies of elastomeric or thermoplastic material) |
- |
|
|
|
24.5 (MECHANICAL STRENGTH
For portable single socket-outlets:
1) with enclosures, covers or bodies of thermoplastic or elastomeric material) |
- |
|
|
|
24.5 (MECHANICAL STRENGTH
For portable multiple and combined socket outlets:
1) with enclosures, covers and bodies of elastomeric or thermoplastic material) |
- |
|
|
|
24.5 (MECHANICAL STRENGTH
For Plug
1) with enclosures, covers and bodies of elastomeric or thermoplastic material) |
- |
|
|
|
24.6 (MECHANICAL STRENGTH
For screwed glands of accessories having an IP code higher than IP20) |
- |
|
|
|
24.3 (MECHANICAL STRENGTH
for fixed socket-outlets with a main part intended to be mounted directly on a surface) |
- |
|
|
|
24.4 (MECHANICAL STRENGTH
For portable single socket-outlets:
1) with enclosures, covers or bodies of thermoplastic or elastomeric material) |
- |
|
|
|
24.4 (MECHANICAL STRENGTH
For portable multiple and combined socket outlets:
1) with enclosures, covers and bodies of elastomeric or thermoplastic material) |
- |
|
|
|
24.4 (MECHANICAL STRENGTH
For Plug
1) with enclosures, covers and bodies of elastomeric or thermoplastic material) |
- |
|
|
|
24.5 (MECHANICAL STRENGTH
For portable single socket-outlets:
1) with enclosures, covers or bodies of thermoplastic or elastomeric material) |
- |
|
|
|
24.5 (MECHANICAL STRENGTH
For portable multiple and combined socket outlets:
1) with enclosures, covers and bodies of elastomeric or thermoplastic material) |
- |
|
|
|
24.5 (MECHANICAL STRENGTH
For Plug
1) with enclosures, covers and bodies of elastomeric or thermoplastic material) |
- |
|
|
|
24.6 (MECHANICAL STRENGTH
For screwed glands of accessories having an IP code higher than IP20) |
- |
|
|
|
24.7 (MECHANICAL STRENGTH
For plug pins provided with insulating sleeves) |
- |
|
|
|
24.8 (MECHANICAL STRENGTH
For shuttered socket-outlets) |
- |
|
|
|
24.9 (MECHANICAL STRENGTH
For portable multiple and combined socket outlets
(1) with enclosures, covers or bodies other than thermoplastic or elastomeric material) |
- |
|
|
|
24.9 (MECHANICAL STRENGTH
For portable multiple and combined socket outlets
(1) with enclosures, covers or bodies other than thermoplastic or elastomeric material) |
- |
|
|
|
24.1 (MECHANICAL STRENGTH
For Plug
(1) with enclosures, covers or bodies other than thermoplastic or elastomeric material) |
- |
|
|
|
24.1 (MECHANICAL STRENGTH
For Plug
(1) with enclosures, covers or bodies of thermoplastic or elastomeric material) |
- |
|
|
|
24.11 (MECHANICAL STRENGTH
For portable socket-outlets having means for suspension on a wall) |
- |
|
|
|
24.12 (MECHANICAL STRENGTH
For portable socket-outlets having means for suspension on a wall) |
- |
|
|
|
24.13 (MECHANICAL STRENGTH
For portable socket-outlets having means for suspension on a wall) |
- |
|
|
|
24.14.1 (MECHANICAL STRENGTH
For fixed socket-outlets) |
- |
|
|
|
24.14.2 (MECHANICAL STRENGTH
For fixed socket-outlets) |
- |
|
|
|
24.14.3 (MECHANICAL STRENGTH
For plugs and portable socket-outlets) |
- |
|
|
|
24.15 (MECHANICAL STRENGTH
) |
- |
|
|
|
24.16 (MECHANICAL STRENGTH
) |
- |
|
|
|
24.16 (MECHANICAL STRENGTH
For shroud of portable socket-outlets) |
- |
|
|
|
25.1 (RESISTANCE TO HEAT
Accessories and surface mounting boxes) |
- |
|
|
|
25.1 (RESISTANCE TO HEAT
Accessories and surface mounting boxes) |
- |
|
|
|
25.2 (RESISTANCE TO HEAT
Parts of insulating material necessary to retain
current-carrying parts of the earthing circuit in position,
as well as parts of the front surface zone of thermoplastic material) |
- |
|
|
|
25.3 (RESISTANCE TO HEAT
Parts of insulating material not necessary to retain current-carrying parts and parts of the earthing circuit in position, even though they are in contact with them) |
- |
|
|
|
25.4 (RESISTANCE TO HEAT
) |
- |
|
|
|
26.1 (SCREWS, CURRENT-CARRYING PARTS AND CONNECTIONS) |
- |
|
|
|
26.2 (SCREWS, CURRENT-CARRYING PARTS AND CONNECTIONS) |
- |
|
|
|
26.4 (SCREWS, CURRENT-CARRYING PARTS AND CONNECTIONS) |
- |
|
|
|
26.7 (SCREWS, CURRENT-CARRYING PARTS AND CONNECTIONS) |
- |
|
|
|
27.1 (CREEPAGE DISTANCES, CLEARANCES AND DISTANCES THROUGH SEALING COMPOUND) |
- |
|
|
|
27.2 (CREEPAGE DISTANCES, CLEARANCES AND DISTANCES THROUGH SEALING COMPOUND) |
- |
|
|
|
27.3 (CREEPAGE DISTANCES, CLEARANCES AND DISTANCES THROUGH SEALING COMPOUND) |
- |
|
|
|
28.1.1 (Resistance to Abnormal Heat and to Fire
Glow-Wire Test) |
- |
|
|
|
28.1.2 (Resistance to Abnormal Heat and to Fire
for plugs with pins provided with insulating sleeves) |
- |
|
|
|
29 (RESISTANCE TO RUSTING) |
- |
|
|
|
25.1 (RESISTANCE TO HEAT
Accessories and surface mounting boxes) |
- |
|
|
|
25.2 (RESISTANCE TO HEAT
Parts of insulating material necessary to retain
current-carrying parts of the earthing circuit in position,
as well as parts of the front surface zone of thermoplastic material) |
- |
|
|
|
25.3 (RESISTANCE TO HEAT
Parts of insulating material not necessary to retain current-carrying parts and parts of the earthing circuit in position, even though they are in contact with them) |
- |
|
|
|
25.4 (RESISTANCE TO HEAT
) |
- |
|
|
|
26.1 (SCREWS, CURRENT-CARRYING PARTS AND CONNECTIONS) |
- |
|
|
|
26.2 (SCREWS, CURRENT-CARRYING PARTS AND CONNECTIONS) |
- |
|
|
|
26.4 (SCREWS, CURRENT-CARRYING PARTS AND CONNECTIONS) |
- |
|
|
|
26.7 (SCREWS, CURRENT-CARRYING PARTS AND CONNECTIONS) |
- |
|
|
|
27.1 (CREEPAGE DISTANCES, CLEARANCES AND DISTANCES THROUGH SEALING COMPOUND) |
- |
|
|
|
27.2 (CREEPAGE DISTANCES, CLEARANCES AND DISTANCES THROUGH SEALING COMPOUND) |
- |
|
|
|
27.3 (CREEPAGE DISTANCES, CLEARANCES AND DISTANCES THROUGH SEALING COMPOUND) |
- |
|
|
|
28.1.1 (Resistance to Abnormal Heat and to Fire
Glow-Wire Test) |
- |
|
|
|
28.1.2 (Resistance to Abnormal Heat and to Fire
for plugs with pins provided with insulating sleeves) |
- |
|
|
|
29 (RESISTANCE TO RUSTING) |
- |
|
|
|
30.1 (ADDITIONAL TESTS ON PINS PROVIDED WITH INSULATING SLEEVES
Pressure Test at High Temperature) |
- |
|
|
|
30.2 (ADDITIONAL TESTS ON PINS PROVIDED WITH INSULATING SLEEVES
Static Damp Heat Test) |
- |
|
|
|
30.3 (ADDITIONAL TESTS ON PINS PROVIDED WITH INSULATING SLEEVES
Tests at Low Temperature) |
- |
|
|
|
30.4 (ADDITIONAL TESTS ON PINS PROVIDED WITH INSULATING SLEEVES
Impact Test at Low Temperature) |
- |
|
|
|
23.2 (FLEXIBLE CABLES AND THEIR CONNECTION) |
- |
|
|
|
9.3 (CHECKING OF DIMENSIONS) |
- |
|
|
|
9.1 (a) (Dimension of plug (6/10A)) |
- |
|
|
|
9.1 (b) (Dimension of plug (6/10A)) |
- |
|
|
|
9.1 (c) (Dimension of plug (6/10A)) |
- |
|
|
|
9.1 (d) (Dimension of plug (6/10A)) |
- |
|
|
|
9.1 (e) (Dimension of plug (6/10A)) |
- |
|
|
|
9.1 (f) (Dimension of plug (6/10A)) |
- |
|
|
|
9.1 (g) (Dimension of plug (6/10A)) |
- |
|
|
|
9.1 (h) (Dimension of plug (16 A)) |
- |
|
|
|
9.1 (i) (Dimension of plug (16 A)) |
- |
|
|
|
9.1 (j) (Dimension of plug (16 A)) |
- |
|
|
|
9.1 (k) (Dimension of plug (16 A)) |
- |
|
|
|
9.1 (l) (Dimension of plug (16 A)) |
- |
|
|
|
9.1 (m) (Dimension of plug (16 A)) |
- |
|
|
|
9.1 (n) () |
- |
|
|
|
10.2 (PROTECTION AGAINST ELECTRIC SHOCK) |
- |
|
|
|
|
Partial
|
|
- |
- |
252 |
IS 398 : Part 5 (1992) |
Aluminium conductor for overhead transmission purposes - Specification: Part 5 aluminium conductors - Galvanized steel - Reinforced for extra high voltage (400 KV And Above) (First Revision) |
-
|
- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
7 (elec) (Freedom from
defects) |
- |
|
|
|
13.2 (mech) (Visual Examination) |
- |
|
|
|
13.3 Table-1 (mech) (Diameter-Aluminium wires) |
- |
|
|
|
13.3 Table-2 (mech) (Diameter-Galvanized Steel wires) |
- |
|
|
|
13.5.1 Table 3 (elec) (Breaking Load on Complete conductor) |
- |
|
|
|
13.5.2 Table 1 (mech) (Breaking Load of Aluminium Wires Before Stranding) |
- |
|
|
|
13.5.2 Table 2 (mech) (Breaking Load of Steel Wires Before Stranding) |
- |
|
|
|
13.5.2 Table 2 (mech) (Breaking Load of Steel Wires After Stranding) |
- |
|
|
|
13.6.1 (mech) (Ductility by Torsion Test before stranding) |
- |
|
|
|
13.6.1 (mech) (Ductility by Torsion Test after stranding) |
- |
|
|
|
13.6.2 (mech) (Ductility by Elongation Test before stranding) |
- |
|
|
|
13.6.2 (mech) (Ductility by Elongation Test after stranding) |
- |
|
|
|
13.7.1 (mech) (Wrapping Test Aluminium Wires Before Stranding) |
- |
|
|
|
13.7.1 (mech) (Wrapping Test Aluminium Wires After Stranding) |
- |
|
|
|
13.7.2 (mech) (Wrapping Test Galvanized Steel Wires Before Stranding) |
- |
|
|
|
13.7.2 (mech) (Wrapping Test Galvanized Steel Wires After Stranding) |
- |
|
|
|
13.8 (elec) (Resistance test-Aluminium wire before Stranding) |
- |
|
|
|
14.8 (elec) (Resistance test-Aluminium wire after stranding) |
- |
|
|
|
13.9.2 (chem) (Mass of Zinc coating) |
- |
|
|
|
13.9.2 (chem) (Uniformity of Zinc coating) |
- |
|
|
|
13.4 Table-4 (mech) (Lay Ratio- Aluminium Wire Outermost Layer) |
- |
|
|
|
13.4 Table-4 (mech) (Lay Ratio- Aluminium Wire Layer Immediately Beneath Outermost Layer) |
- |
|
|
|
13.4 Table-4 (mech) (Lay Ratio- Aluminium Wire Innermost Layer of Conductors eith 3 Aluminium Wire Layers) |
- |
|
|
|
13.4 Table-4 (mech) (Lay Ratio- Steel Core (6 Wire Layer)) |
- |
|
|
|
10.4 (mech) (Direction of lay) |
- |
|
|
|
13.5.2 Table 1 (mech) (Breaking Load of Aluminium Wires After Stranding) |
- |
|
|
|
|
Partial
|
|
- |
- |
253 |
IS 6003 (2010) |
Indented Wire For--Prestressed Concrete ” |
-
|
- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
4.1.1 (Phosphorus %) |
- |
|
|
|
4.1.1 (Sulphur %) |
- |
|
|
|
Cl 7.1 (Tensile Test On UTM) |
- |
|
|
|
Cl 7.2 (Tensile Test On UTM) |
- |
|
|
|
Cl 7.3 (Reverse Bend Test) |
- |
|
|
|
Cl 7.4 (Tensile Test On UTM) |
- |
|
|
|
Cl 5.1 (Diameter) |
- |
|
|
|
Cl 6.1.2 (Weight) |
- |
|
|
|
|
Partial
|
|
- |
- |
254 |
IS 398 : Part 4 (1994) |
Aluminium conductors for overhead transmission purposes: Part 4 aluminium alloy stranded conductors (Aluminium - Magnesium - Silicon Type) - Specification (Third Revision) |
-
|
- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
6.1 (Freedom from Defects) |
- |
|
|
|
7.1 Table-1 (Dimensional measurement of wires) |
- |
|
|
|
7.2.2 Table-2, Table-4 (Calculated resistance of Stranded Conductor) |
- |
|
|
|
8.1 (Joints in wires-Conductors Containing Seven Wires) |
- |
|
|
|
8.2 (Joints in wires-Conductors Containing More Than Seven Wires) |
- |
|
|
|
9.2 Table 3 (Lay Ratio of stranded conductors) |
- |
|
|
|
9.3 (Direction of Lay) |
- |
|
|
|
9.4 (Multiple layers of wires) |
- |
|
|
|
11 (Packing and Marking) |
- |
|
|
|
12.2 Table 1 (Breaking Load Test- Before Stranding) |
- |
|
|
|
12.2 Table 1 (Breaking Load Test- After Stranding) |
- |
|
|
|
12.3 Table 1 (Elongation Test- Before Stranding) |
- |
|
|
|
12.3 Table 1 (Elongation Test- After Stranding) |
- |
|
|
|
12.4 Table 1 (Resistance of Aluminium wire) |
- |
|
|
|
|
Partial
|
|
- |
- |
255 |
IS 398 : Part 1 (1996) |
Aluminium conductors for overhead transmission purposes - Specification: Part 1 aluminium stranded conductors (Third Revision) |
-
|
- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
6 (Freedom from defects) |
- |
|
|
|
9.3 (Stranding) |
- |
|
|
|
12.6, Table 3 (Measurement of lay ratio) |
- |
|
|
|
12.5, Table 1 (Resistance test) |
- |
|
|
|
12.4 (Wrapping test) |
- |
|
|
|
12.3, Table-1 (Breaking load after stranding) |
- |
|
|
|
12.3, Table-1 (Breaking load before stranding) |
- |
|
|
|
12.2, Table-1 (Measurement of diameter of individual aluminium wire) |
- |
|
|
|
|
Partial
|
|
- |
- |
256 |
IS 371 (1999) |
Ceiling roses - Specification (Third Revision) |
-
|
- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
9 (Marking) |
- |
|
|
|
10.1 (Dimentions) |
- |
|
|
|
10.2 (Dimentions) |
- |
|
|
|
11.1 (Accessibility of live parts ) |
- |
|
|
|
11.2 (Accessibility of live parts ) |
- |
|
|
|
11.3 (Accessibility of live parts ) |
- |
|
|
|
11.4 (Accessibility of live parts ) |
- |
|
|
|
11.4.1 (Accessibility of live parts ) |
- |
|
|
|
12.1 (Provision for Earthing) |
- |
|
|
|
12.2 (Provision for Earthing) |
- |
|
|
|
13.1 (Terminals) |
- |
|
|
|
13.2 (Terminals) |
- |
|
|
|
13.3 (Terminals) |
- |
|
|
|
13.4 (Terminals) |
- |
|
|
|
13.5 (Terminals) |
- |
|
|
|
13.6 (Terminals) |
- |
|
|
|
13.7 (Terminals) |
- |
|
|
|
13.8.1 (Terminals) |
- |
|
|
|
13.8.2 (Terminals) |
- |
|
|
|
13.8.3 (Terminals) |
- |
|
|
|
14.1 (Construction) |
- |
|
|
|
14.2 (Construction) |
- |
|
|
|
14.3 (Construction) |
- |
|
|
|
14.4 (Construction) |
- |
|
|
|
15.1 (RESISTANCE TO MOISTURE AND HUMIDITY, INSULATION RESISTANCE AND ELECTRIC STRENGTH) |
- |
|
|
|
15.2 (RESISTANCE TO MOISTURE AND HUMIDITY, INSULATION RESISTANCE AND ELECTRIC STRENGTH) |
- |
|
|
|
15.3 (RESISTANCE TO MOISTURE AND HUMIDITY, INSULATION RESISTANCE AND ELECTRIC STRENGTH) |
- |
|
|
|
15.4 (RESISTANCE TO MOISTURE AND HUMIDITY, INSULATION RESISTANCE AND ELECTRIC STRENGTH) |
- |
|
|
|
15.5 (RESISTANCE TO MOISTURE AND HUMIDITY, INSULATION RESISTANCE AND ELECTRIC STRENGTH) |
- |
|
|
|
15.7 (RESISTANCE TO MOISTURE AND HUMIDITY, INSULATION RESISTANCE AND ELECTRIC STRENGTH) |
- |
|
|
|
16 (Temperature Rise Test) |
- |
|
|
|
17 (Temperature Rise Test) |
- |
|
|
|
18 (Resistance to heat) |
- |
|
|
|
19 (Resistance to abnormal heat fire and tracking) |
- |
|
|
|
19.2 (Resistance to abnormal heat fire and tracking) |
- |
|
|
|
20.1 (SCREWS, CURRENT-CARRYING PARTS AND CONNECTIONS) |
- |
|
|
|
20.2 (SCREWS, CURRENT-CARRYING PARTS AND CONNECTIONS) |
- |
|
|
|
20.3 (SCREWS, CURRENT-CARRYING PARTS AND CONNECTIONS) |
- |
|
|
|
21.1 (CREEPAGE DISTANCE AND CLEARANCES) |
- |
|
|
|
22.1 (Resistance to Excessive residual Stress and to Rusting ) |
- |
|
|
|
22.1 (Resistance to Excessive residual Stress and to Rusting ) |
- |
|
|
|
22.1 (Resistance to Excessive residual Stress and to Rusting ) |
- |
|
|
|
|
Partial
|
|
- |
- |
257 |
IS 204 : Part 1 (1991) |
Tower bolts - Specification: Part 1 ferrous metals (Fifth Revision) |
-
|
- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
4 -Table 5- i (Ref. Cl 7, Table 3, HR1 grade of IS 1079 : 2017) (Chemical composition - Carbon - IS 228) |
- |
|
|
|
4 -Table 5- i (Ref. Cl 7, Table 3, HR1 grade of IS 1079 : 2017) (Chemical composition - Manganese - IS 228) |
- |
|
|
|
4 -Table 5- i (Ref. Cl 7, Table 3, HR1 grade of IS 1079 : 2017) (Chemical composition - Phosphorus - IS 228) |
- |
|
|
|
4 -Table 5- i (Ref. Cl 7, Table 3, HR1 grade of IS 1079 : 2017) (Chemical composition - Sulphur - IS 228) |
- |
|
|
|
4 -Table 5- ii (Ref. Cl 5, Table 1, E300-C grade of IS 2062 : 2011) (Chemical composition - Silicon - IS 228) |
- |
|
|
|
6.1- Table 1 (Dimension of Barrel tower bolts-1.Size 2.Length of Bolt-A 3.Length of Barrel-B 4.Width of Barrel-C 5.Dia of Bolt-D 6.Length of Socket-E 7.Thickness of mild steel sheet for barrel-F 8.Dia of bore of barrel or socket- G ) |
- |
|
|
|
6.2- Table 2 (Dimension of Sami Barrel Tower Bolts 1.Size 2.Length of Bolt-A 3.Length of Bolt Plate-B 4.Width of Bolt Plate-C 5.Dia of Bolt-D 6.Length of Socket-E 7.Thickness of Bolt Plate or Socket-F 8.Dia of bore of Bolt Plate or socket G ) |
- |
|
|
|
6.2- Table 2 (Dimension of Sami Barrel Tower Bolts-Minimum No. of equally Spaced Screw holes in Bolt Plate and Socket for wood screw no 6) |
- |
|
|
|
|
Partial
|
|
- |
- |
258 |
IS 814 (2004) |
Covered electrodes for manual metal arc welding of carbon and carbon manganese steel - Specification (Sixth Revision) |
-
|
- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
7.1.1 (Diameter of Core Wire) |
- |
|
|
|
7.2.1 (Contact End) |
- |
|
|
|
6 & 8.2 (Carbon- Relevant Parts of IS 228 or any other established instrumental/chemical method) |
- |
|
|
|
6 & 8.2 (Manganese- Relevant Parts of IS 228 or any other established instrumental/chemical method) |
- |
|
|
|
6 & 8.2 (Phosphorous- Relevant Parts of IS 228 or any other established instrumental/chemical method) |
- |
|
|
|
6 & 8.2 (Sulphur- Relevant Parts of IS 228 or any other established instrumental/chemical method) |
- |
|
|
|
7.1.2 (Length of Electrodes) |
- |
|
|
|
7.3 (Concentricity of Flux covering with core wire) |
- |
|
|
|
7.2.2 (Arc striking End) |
- |
|
|
|
|
Partial
|
|
- |
- |
259 |
IS 12818 (2010) |
Unplasticized polyvinyl chloride (Pvc - U) screen and casing pipes for bore/tubewells - Specification (Second Revision) |
-
|
- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
7.2 and Table 5, 6 & 7
Fig 1B (Mean Outer Diameter of Pipe, Min) |
- |
|
|
|
7.2 and Table 5, 6 & 7
Fig 1B (Mean Outer Diameter of Pipe , Max) |
- |
|
|
|
7.2 and Table 5, 6 & 7
Fig 1B (Outer Diameter at any point , Min) |
- |
|
|
|
7.2 and Table 5, 6 & 7
Fig 1B (Outer Diameter at any point, Max) |
- |
|
|
|
7.2 and Table 5, 6 & 7
Fig 1B (Mean Outer Diameter over Connection) |
- |
|
|
|
7.2 and Table 5, 6 & 7
Fig 1B (Wall thickness, Min) |
- |
|
|
|
7.2 and Table 5, 6 & 7
Fig 1B (Wall thickness, Max) |
- |
|
|
|
7.4 Table 8 & 9
Fig 1 (Segmental length, l3) |
- |
|
|
|
9.3 (Density
IS 12235 (Part 14)) |
- |
|
|
|
9.5 (Tensile Strength
IS 12235(Part 13)) |
- |
|
|
|
9.6 (Vicat Softening Temperature
IS 12235 (Part 2).) |
- |
|
|
|
7.4 Table 8 & 9
Fig 1 (Effective length, l2) |
- |
|
|
|
7.4 Table 8 & 9
Fig 1 (Segmental length, l4) |
- |
|
|
|
7.4 Table 8 & 9
Fig 1 (Segmental length, l5) |
- |
|
|
|
9.5 (Tensile Strength
IS 12235(Part 13)) |
- |
|
|
|
|
Partial
|
|
- |
- |
260 |
IS 398 : Part 2 (1996) |
Aluminium conductors for overhead transmission purposes - Specification: Part 2 aluminium conuuctors, galvanized steel - Reinforced (Third Revision) |
-
|
- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
10 (elec) (Stranding) |
- |
|
|
|
10 (elec) (Stranding) |
- |
|
|
|
10 (elec) (Stranding) |
- |
|
|
|
13.4.2 (elec) (Ductility by Elongation Test before stranding) |
- |
|
|
|
13.4.2 (elec) (Ductility by Elongation Test after stranding) |
- |
|
|
|
13.6 (elec) (Resistance test-Aluminium wire before Stranding) |
- |
|
|
|
13.6 (elec) (Resistance test-Aluminium wire after stranding) |
- |
|
|
|
13.9 (elec) (Surface condition test) |
- |
|
|
|
13.10 (elec) (Ultimate breaking load) |
- |
|
|
|
13.11 (elec) (Stress-strain test) |
- |
|
|
|
13.8 Table-4 (elec) (Lay Ratio- Steel Core (6 Wire Layer)) |
- |
|
|
|
13.8 Table-4 (elec) (Lay Ratio- Steel Core (6 Wire Layer)) |
- |
|
|
|
13.8 Table-4 (elec) (Lay Ratio- Aluminium Wire Innermost Layer of Conductors with 3 Aluminium Wire Layers) |
- |
|
|
|
13.8 Table-4 (elec) (Lay Ratio- Aluminium Wire Layer Immediately Beneath Outermost Layer) |
- |
|
|
|
13.8 Table-4 (elec) (Lay Ratio- Aluminium Wire Outermost Layer) |
- |
|
|
|
13.7.2 (elec) (Uniformity of Zinc coating) |
- |
|
|
|
13.7.2 (elec) (Mass of Zinc coating) |
- |
|
|
|
13.5.2 (elec) (Wrapping Test Galvanized Steel Wires After Stranding) |
- |
|
|
|
13.5.2 (elec) (Wrapping Test Galvanized Steel Wires Before Stranding) |
- |
|
|
|
13.5.1 (elec) (Wrapping Test Aluminium Wires After Stranding) |
- |
|
|
|
13.5.1 (elec) (Wrapping Test Aluminium Wires Before Stranding) |
- |
|
|
|
13.4.1 (elec) (Ductility by Torsion Test after stranding) |
- |
|
|
|
13.4.1 (elec) (Ductility by Torsion Test before stranding) |
- |
|
|
|
13.3 Table 2 (elec) (Breaking Load of Steel Wires After Stranding) |
- |
|
|
|
13.3 Table 2 (elec) (Breaking Load of Steel Wires Before Stranding) |
- |
|
|
|
13.3 Table 1 (elec) (Breaking Load of Aluminium Wires After Stranding) |
- |
|
|
|
13.3 Table 1 (elec) (Breaking Load of Aluminium Wires Before Stranding) |
- |
|
|
|
8.1.1 & 13.2 Table 2 (elec) (Diameter of Steel Wires After Stranding) |
- |
|
|
|
8.1.1 & 13.2 Table-1 (elec) (Diameter of Aluminium Wires After Stranding) |
- |
|
|
|
8.1.1 & 13.2 Table 2 (elec) (Diameter of Steel Wires Before Stranding) |
- |
|
|
|
8.1.1 & 13.2 Table-1 (elec) (Diameter of Aluminium Wires Before Stranding) |
- |
|
|
|
|
Partial
|
|
- |
- |
261 |
IS 3854 (1997) |
Switches for domestic and similar purposes - Specification (Second Revision) |
-
|
- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
10 (Protection against Electric Shock) |
- |
|
|
|
11.1 (Provision for earthing) |
- |
|
|
|
12.2.3 (Mechanical strength of terminals) |
- |
|
|
|
12.2.4 (Resistance to corrosion) |
- |
|
|
|
12.2.5 (Undue damage to conductor) |
- |
|
|
|
12.2.7 (Insertion of conductor) |
- |
|
|
|
12.2.11 (Distance between screw and conductor) |
- |
|
|
|
12.3.2 (Screwless terminals) |
- |
|
|
|
12.3.4 (Material of terminals) |
- |
|
|
|
12.3.11 (vi) Electrical & Thermal Stresses [Cl 12.3.11]) |
- |
|
|
|
12.3.12 (vii) Deflection Stresses [Cl. 12.3.12]) |
- |
|
|
|
13.15 (q) Requirements for membrane in inlet opening [ Cl. 13.15]) |
- |
|
|
|
15.1 (Resistance to Ageing, to Harmful Ingress of water and to Humidity [Cl. 15]: Resistance to Ageing, [Cl. 15.1]) |
- |
|
|
|
15.2 (b)Resistance to Harmful ingress of water [Cl. 15.2]) |
- |
|
|
|
15.3 (c) Resistance to Humidity [Cl. 15.3]) |
- |
|
|
|
16.1 (Insulation resistance [Cl. 16.1]) |
- |
|
|
|
16.2 ( Electric Strength [Cl. 16.2]) |
- |
|
|
|
17 (Temperature- rise [Cl. 17]) |
- |
|
|
|
19 (Normal Operation [Cl. 19] a) General & Operation) |
- |
|
|
|
19 (b) Electric Strength) |
- |
|
|
|
19 (c)Temperature-rise ) |
- |
|
|
|
19.2 (Normal Operation (For AX type Switches) [Cl. 19.2]) |
- |
|
|
|
20 (Mechanical Strength Test [Cl. 20]) |
- |
|
|
|
21 (Resistance to Heat [Cl.21]) |
- |
|
|
|
22 (Screw, Current Carrying Part And Connection [Cl.22]) |
- |
|
|
|
23.2 (Creepage distances, clearances and distance through sealing compound [Cl.23]) |
- |
|
|
|
24.1.1 (Resistance to Abnormal Heat & Fire [Cl.24.1] [Glow Wire Test] [Cl.24.1.1]) |
- |
|
|
|
8 (Marking) |
- |
|
|
|
8 (Marking) |
- |
|
|
|
8 (Marking) |
- |
|
|
|
8 (Marking) |
- |
|
|
|
8 (Marking) |
- |
|
|
|
8 (Marking) |
- |
|
|
|
8 (Marking) |
- |
|
|
|
8.9 (Marking) |
- |
|
|
|
8 (Marking) |
- |
|
|
|
7 (Classification) |
- |
|
|
|
7 (Classification) |
- |
|
|
|
7 (Classification) |
- |
|
|
|
7 (Classification) |
- |
|
|
|
7 (Classification) |
- |
|
|
|
7 (Classification) |
- |
|
|
|
7 (Classification) |
- |
|
|
|
12 (Terminals) |
- |
|
|
|
12.2.1 (Terminals) |
- |
|
|
|
12 (Terminals) |
- |
|
|
|
12.2.2 (Connection of conductor) |
- |
|
|
|
12.2.7 (Insertion of conductor) |
- |
|
|
|
12.2.9 (Locking against accidental loosening) |
- |
|
|
|
12.3.2 (Screwless terminals) |
- |
|
|
|
12.3.3 (Connectin of conductor) |
- |
|
|
|
12.3.4 (Material of terminals) |
- |
|
|
|
12.3.5 (Clamping) |
- |
|
|
|
12.3.7 (v) Interconnection of conductors [Cl. 12.3.7]) |
- |
|
|
|
13.1 (a) Insulating lining, barriers and the like [Cl 13.1]) |
- |
|
|
|
13.2 (b) Construction of switch [Cl 13.2]) |
- |
|
|
|
13.2 (i) Installation Test) |
- |
|
|
|
13.3 (c) Covers,cover plates and actuating members [Cl 13.3]) |
- |
|
|
|
13.4 (d) Ordinary switches [Cl 13.4]) |
- |
|
|
|
13.5 (e) Rotary switches [Cl 13.5]) |
- |
|
|
|
13.6 (f) Screws and other means [Cl 13.6]) |
- |
|
|
|
12.3.7 (v) Interconnection of conductors [Cl. 12.3.7]) |
- |
|
|
|
13.8 (h) Assessories combined with switches [Cl. 13.8]) |
- |
|
|
|
13.9 (j) Switches other than ordinary switches [Cl. 13.9]) |
- |
|
|
|
13.9 (j) Switches other than ordinary switches [Cl. 13.9]) |
- |
|
|
|
13.1 (k) Switches to be installed in a box [Cl. 13.10]) |
- |
|
|
|
13.12, 13.13, 13.14 (m) Inlet opening [Cl. 13.12.13.13 & 13.14]) |
- |
|
|
|
13.15 (q) Requirements for membrane in inlet opening [ Cl. 13.15]) |
- |
|
|
|
13.15 (q) Requirements for membrane in inlet opening [ Cl. 13.15]) |
- |
|
|
|
14 (Mechanism [Cl. 14]) |
- |
|
|
|
14.4 (Mechanism) |
- |
|
|
|
8 (Marking) |
- |
|
|
|
8 (Marking) |
- |
|
|
|
14.4 (Mechanism) |
- |
|
|
|
14.3 (d)Test for arcing and sparking [Cl 14.3]) |
- |
|
|
|
21 (Resistance to Heat [Cl.21]) |
- |
|
|
|
21 (Resistance to Heat [Cl.21]) |
- |
|
|
|
23 (Creepage distances, clearances and distance through sealing compound [Cl.23]) |
- |
|
|
|
24.2 (Resistance to tracking [For Switch other than ordinary] [Cl.24.2]) |
- |
|
|
|
19.2 (Normal Operation (For AX type Switches) [Cl. 19.2]) |
- |
|
|
|
22.1 (i) Screw & Nuts [Cl.22.1]) |
- |
|
|
|
22.3 (iii) Electrical Connections [Cl.22.3]) |
- |
|
|
|
22.4 (ii) Screw & rivets [Cl . 22.4]) |
- |
|
|
|
22.5 (iv) Current carrying part [Cl.22.5]) |
- |
|
|
|
18 (Marking and breaking Capacity[Cl. 18]) |
- |
|
|
|
7 (Classification) |
- |
|
|
|
7 (Classification) |
- |
|
|
|
6.1 (Ratings) |
- |
|
|
|
6.2 (Ratings) |
- |
|
|
|
25 (Resistance to Rusting) |
- |
|
|
|
|
Partial
|
|
- |
- |
262 |
IS 694 (2010) |
Polyvinyl chloride insulated unsheathed and sheathed cables/cords with rigid and flexible conductor for rated voltages up to and including 450/750 v (Fourth Revision) |
-
|
- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
table 1 e) 3) (IR constant- Room temp ) |
- |
|
|
|
table 1 e) 3) (IR constant- max. Temp) |
- |
|
|
|
10.2 (HV (room temperature)) |
- |
|
|
|
10.1 (HV (water immersion)) |
- |
|
|
|
Table 1 iii) d) 9) (Cold impact for sheath) |
- |
|
|
|
Table 1 iii) d) 8) (Cold bend for sheath) |
- |
|
|
|
Table 1 iii) c) 9) (Cold impact for insulation) |
- |
|
|
|
Table 1 iii) c) 8) (Cold bend for insulation) |
- |
|
|
|
Table 1 iii) d) 7) (Thermal stability- Sheath ) |
- |
|
|
|
Table 1 iii) c) 7) (Thermal stability- Insulation ) |
- |
|
|
|
Table 1 iii) d) 6) (Hot deformation -Indentation depth - Sheath ) |
- |
|
|
|
Table 1 iii) d) 5) (Heat shock-Sheath ) |
- |
|
|
|
Table 1 iii) c) 5) (Heat shock-Insulation ) |
- |
|
|
|
Table 1 iii) d) 4) (Shrinkage- Sheath ) |
- |
|
|
|
Table 1 iii) c) 4) (Shrinkage-Insulation) |
- |
|
|
|
Table 1 iii) d) 2) (Loss of mass- Sheath ) |
- |
|
|
|
Table 1 iii) c) 2) (Loss of mass- Insulation ) |
- |
|
|
|
Table 1 iii) d) 3) (Sheath- Elongation variation) |
- |
|
|
|
Table 1 iii) d) 3) (Sheath- TS variation) |
- |
|
|
|
Table 1 iii) d) 3) (Sheath- Elongation (After ageing)) |
- |
|
|
|
Table 1 iii) d) 3) (Sheath- Tensile strength (After ageing)) |
- |
|
|
|
Table 1 iii) d) 1) (Sheath- Elongation (Without ageing)) |
- |
|
|
|
Table 1 iii) c) 3) (Elongation variation) |
- |
|
|
|
Table 1 iii) c) 3) (TS variation) |
- |
|
|
|
Table 1 iii) c) 3) (Elongation (After ageing)) |
- |
|
|
|
Table 1 iii) c) 3) (Tensile strength (After ageing)) |
- |
|
|
|
Table 1 iii) c) 1) (Elongation (Without ageing)) |
- |
|
|
|
Table 1 iii) c) 1) (Tensile strength (Without ageing)) |
- |
|
|
|
4.2 (Conductor resistance test) |
- |
|
|
|
4.1 (Wrapping test (for Al)) |
- |
|
|
|
4.1 (Tensile test (for Al)- After Stranding) |
- |
|
|
|
4.1 (Tensile test (for Al)-Before Stranding) |
- |
|
|
|
4.1 (Annealing test (for copper)) |
- |
|
|
|
(Cl.16.1)
(Cl.19.1) (Conductor- Diameter ) |
- |
|
|
|
10.9 (Additional ageing test (OU cables only) -HV test (at 60±3oC)) |
- |
|
|
|
11.2 (Legibility) |
- |
|
|
|
11.1 (Durability) |
- |
|
|
|
11 (Identification) |
- |
|
|
|
10.9 (Additional ageing test (OU cables only) -HV test (at 60±3oC)) |
- |
|
|
|
10.4 (Flammability test- Unaffected portion) |
- |
|
|
|
10.4 (Flammability test-Burning after flame removal) |
- |
|
|
|
Table 1 iii) d) 4) (Cracks Observed) |
- |
|
|
|
Table 1 iii) c) 4) (Cracks Observed) |
- |
|
|
|
(Cl. 18.1.4)
(Cl. 19.1.5)
(Cl. 20.1.4)
(Cl. 22.1.4) (Colour of Sheath) |
- |
|
|
|
5.2 (Application ) |
- |
|
|
|
9.1 (Ovality) |
- |
|
|
|
(Cl.6.1.3 of IS 8130:2013) (Flexible Conductors (Classes 5)) |
- |
|
|
|
(Cl.6.1.3 of IS 8130:2013) ( Flexible Conductors (Classes 5)) |
- |
|
|
|
(Cl.6.1.3 of IS 8130:2013) (Stranded circular non compacted conductors(Class-2)) |
- |
|
|
|
(Cl.6.1.3 of IS 8130:2013) (Stranded compacted circular conductors and shaped conductors (Class 2)) |
- |
|
|
|
(Cl.6.1.3 of IS 8130:2013) (Stranded circular non compacted conductors (Class-2)) |
- |
|
|
|
(Cl.6.1.3 of IS 8130:2013) (Solid Conductor (Class 1)) |
- |
|
|
|
(Cl.6.1 of IS 8130:2013) (Solid Conductor (Class 1)) |
- |
|
|
|
(Cl.6.1 of IS 8130:2013) (Solid Conductor (Class 1)) |
- |
|
|
|
(Cl.16.1)
(Cl.19.1) (Conductor) |
- |
|
|
|
(Cl.16.1)
(Cl.19.1) (Conductor) |
- |
|
|
|
(Cl.16.1)
(Cl.19.1) (Conductor) |
- |
|
|
|
(Cl. 18.1.3)
(Cl. 19.1.4)
(Cl. 20.1.3)
(Cl. 21.1.3)
(Cl. 22.1.3) (Assembly of cores ) |
- |
|
|
|
12 (CONSTRUCTION Core Identification) |
- |
|
|
|
8.1 (Sheath Material ) |
- |
|
|
|
7 (Binder Tape) |
- |
|
|
|
6.1 (Filler) |
- |
|
|
|
6.2 (Filler) |
- |
|
|
|
5.1 (Insulation) |
- |
|
|
|
4.4 (Joints in Conductor) |
- |
|
|
|
4.4 (Joints in Conductor) |
- |
|
|
|
4.1 (Conductor - Material) |
- |
|
|
|
4.1 (Conductor - Material) |
- |
|
|
|
11 (Identification) |
- |
|
|
|
8.3 (Thickness of Sheath) |
- |
|
|
|
4.1 (Annealing test (for copper)) |
- |
|
|
|
9 (Overall dimensions) |
- |
|
|
|
Table 1 iii) c) 6) (Hot deformation - Indentation depth- Insulation) |
- |
|
|
|
Table 1 iii) d) 1) (Sheath -Tensile strength (Without ageing)) |
- |
|
|
|
8.3 (Minimum thickness of Sheath) |
- |
|
|
|
8.3 (Avarage thickness of Sheath) |
- |
|
|
|
5.3 (Minimum thickness of insulation) |
- |
|
|
|
5.3 (Avarage thickness of insulation) |
- |
|
|
|
Table 1 iii) c) 1) (Elongation (Without ageing)) |
- |
|
|
|
|
Partial
|
|
- |
- |
263 |
IS 1554 : Part 1 (1988) |
Specification for pvc insulated (Heavy Duty) electric cables: Part 1 for working voltages up to and including 1100 v (Third Revision) |
-
|
- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
9.2 (INSULATION : Thickness of Insulation) |
- |
|
|
|
12.3 (INNER SHEATH :Thickness of Inner Sheath) |
- |
|
|
|
13.3 (Armouring : Dimensions -Wire Diameter) |
- |
|
|
|
13.3 (Armouring : Dimensions -Formed wire ) |
- |
|
|
|
13.6 f) (ARMOURING: Mass of zinc coating ) |
- |
|
|
|
13.6 a) (ARMOURING: Tensile Strength) |
- |
|
|
|
13.6 c) (ARMOURING: Torsion Test (For round wire ) ) |
- |
|
|
|
13.6 d) (ARMOURING: Winding Test(For formed wire)) |
- |
|
|
|
13.6 f) (ARMOURING: Mass of zinc coating ) |
- |
|
|
|
13.6 g) (ARMOURING: Resistivity) |
- |
|
|
|
14.4.1 (Thickness of Outer Sheath : Unarmowed Cables) |
- |
|
|
|
15.1 a) 1) (Tests on conductor : Annealing test ( for copper )) |
- |
|
|
|
15.1 a) 4) (Tests on conductor : Conductor resistance test) |
- |
|
|
|
15.1 a) 4) (Resistance test - Neutral conductor ) |
- |
|
|
|
15.1 d)1) (Phyaical tests for insulation : Tensile Test) |
- |
|
|
|
15.1 d)1) (Phyaical tests for insulation : Elongation ) |
- |
|
|
|
15.1 d)2) (Phyaical tests for insulation - Ageing in air Oven : Tensile Variation ) |
- |
|
|
|
15.1 d)2) (Phyaical tests for insulation- Ageing in air oven : Elongation Variation ) |
- |
|
|
|
15.1 d)2) (Physical tests for outer sheath- Ageing in air oven : Tensile stregth ) |
- |
|
|
|
15.1 d)2) (Physical tests for outer sheath -Ageing in air oven : Elongation ) |
- |
|
|
|
15.1 d)2) (Physical tests for outer sheath- Ageing in air oven : Tensile stregth Variation ) |
- |
|
|
|
15.1 d)2) (Physical tests for outer sheath -Ageing in air oven : Elongation Variation ) |
- |
|
|
|
15.1 d)3) (Phyaical tests for insulation : Shrinkage ) |
- |
|
|
|
15.1 d)3) (Phyaical tests for Sheath : Shrinkage ) |
- |
|
|
|
15.1 d)4) (Hot deformation : Insulation ) |
- |
|
|
|
15.1 d)4) (Hot deformation : Sheath ) |
- |
|
|
|
15.1 d)5) ( Loss of mass in air oven- Insulation ) |
- |
|
|
|
15.1 d)5) ( Loss of mass in air oven- sheath ) |
- |
|
|
|
15.1 d)6) (Heat shock test- Insulation ) |
- |
|
|
|
15.1 d)6) (Heat shock test- sheath ) |
- |
|
|
|
15.1 d)7) (Thermal stability- insulation ) |
- |
|
|
|
15.1 d)7) (Thermal stability- Sheath ) |
- |
|
|
|
15.1.e (Insulation resistance Test- Insulation resistance constant At Room temperature) |
- |
|
|
|
15.1.e (Insulation resistance Test- Insulation resistance At Maximum rated temperature temperature) |
- |
|
|
|
15.4 a) (Cold bend test- Insulation ( Optional test)) |
- |
|
|
|
15.4 a) (Cold bend test- Sheath ( Optional test)) |
- |
|
|
|
15.4 b) (Cold impact test- Insulation ( Optional test)) |
- |
|
|
|
15.4 b) (Cold impact test- Sheath ( Optional test)) |
- |
|
|
|
15.4 c) (Armour resistance test ( for other than mining cables ).- Optional test ) |
- |
|
|
|
16.2 (DETAILS OF TESTS : High Voltage Test at Room Temperature) |
- |
|
|
|
16.3.1 (High Voltage Test ( Water Immersion Test ) : a.c. Test) |
- |
|
|
|
16.3.2 (High Voltage Test ( Water Immersion Test ) : d.c. Test) |
- |
|
|
|
16.4 (Flammability Test) |
- |
|
|
|
3.1 (MATERIALS : CONDUCTOR) |
- |
|
|
|
4.1.1 (INSULATION : General Purjose Insulaiion) |
- |
|
|
|
4.1.2 (INSULATION : Heat Resisting Insulation) |
- |
|
|
|
5.1 (MATERIALS : FILLER AND INNER SHEATH) |
- |
|
|
|
5.2 (MATERIALS : FILLER AND INNER SHEATH) |
- |
|
|
|
6.1 (MATERIALS : ARMGURING) |
- |
|
|
|
7.1.1 (OUTER SHEATH : For Cables with General Purpose InsuIafion) |
- |
|
|
|
7.1.2 (OUTER SHEATH : For Cables with Heat Resisting InsuIalion) |
- |
|
|
|
8.1 (CONSTRUCTION : CONDUCTOR) |
- |
|
|
|
8.2 (CONSTRUCTION : CONDUCTOR) |
- |
|
|
|
9.1 (INSULATION ) |
- |
|
|
|
9.3 (INSULATION :Tolerance on Thickness of Insulation) |
- |
|
|
|
9.4 (INSULATION : Application of Insulation) |
- |
|
|
|
10.1 (CORE IDENTIFICATION) |
- |
|
|
|
10.2 (CORE IDENTIFICATION) |
- |
|
|
|
10.3 (CORE IDENTIFICATION) |
- |
|
|
|
10.3.1 (Arrangement of Marking) |
- |
|
|
|
11.1 (LAYING UP OF CORES) |
- |
|
|
|
11.2 (LAYING UP OF CORES) |
- |
|
|
|
12.1 (INNER SHEATH) |
- |
|
|
|
12.2 (INNER SHEATH) |
- |
|
|
|
13.1.1 (ARMOURING : Application) |
- |
|
|
|
13.1.2 (Armouring: Coverage ) |
- |
|
|
|
13.1.3 (ARMOURING : Direction of lay ) |
- |
|
|
|
13.1.4 (ARMOURING : Application) |
- |
|
|
|
13.2 (ARMOURING : Type of Armour) |
- |
|
|
|
13.2.1 (ARMOURING : Type of Armour) |
- |
|
|
|
13.4 (ARMOURING : Joints) |
- |
|
|
|
13.5.2 (ARMOURING : Resistance) |
- |
|
|
|
13.6 b) (ARMOURING: Elongation ) |
- |
|
|
|
13.6 e) (ARMOURING: Uniformity of zinc coating) |
- |
|
|
|
14.1 (OUTER SHEATH) |
- |
|
|
|
14.2 (OUTER SHEATH) |
- |
|
|
|
14.3 (OUTER SHEATH : Colour ) |
- |
|
|
|
14.4.2 (Thickness of Outer Sheath : Armoured Cables) |
- |
|
|
|
15.1 a) 2) (Tensile test (for aluminium) - Before stranding ) |
- |
|
|
|
15.1 a) 2) (Tensile test (for aluminium) - After stranding ) |
- |
|
|
|
15.1 a) 3) (Tests on conductor : Wrapping test ( for aluminium )) |
- |
|
|
|
17.1 (IDENTIFICATION : Manufacturer’s Identification) |
- |
|
|
|
17.2 (IDENTIFICATION : Cable Identification) |
- |
|
|
|
17.2.1 (IDENTIFICATION : Cable Identification) |
- |
|
|
|
17.3 (IDENTIFICATION : Cable Code) |
- |
|
|
|
9.3 (Minimum Thickness of Reduce core insulation) |
- |
|
|
|
9.2 (Thickness of Reduce core insulation) |
- |
|
|
|
15.1 d)2) (Phyaical tests for insulation- Ageing in air Oven : Tensile Test) |
- |
|
|
|
15.1 d)2) (Phyaical tests for insulation - Ageing in air oven : Elongation ) |
- |
|
|
|
15.1 d)1) (Physical tests for sheath : Tensile stregth ) |
- |
|
|
|
15.1 d)1) (Physical tests for sheath : Elongation ) |
- |
|
|
|
|
Partial
|
|
- |
- |
264 |
IS 13334 : Part 1 (2014) |
Skimmed milk powder - Specification: Part 1 standard grade (Second Revision) |
-
|
- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
5.6 (Listeria monocytogenes) |
- |
|
|
|
5.6 (Spore count, Anaerobic (Sulfite reducing Clostridia)) |
- |
|
|
|
5.6 (Spore count, Aerobic (Bacillus cereus)) |
- |
|
|
|
5.6 (Salmonella) |
- |
|
|
|
5.6 (Coagulase positive Staphylococcus aureus) |
- |
|
|
|
5.6 (Escherichia coli) |
- |
|
|
|
5.6 (Coliform count ) |
- |
|
|
|
5.6 (Bacterial count) |
- |
|
|
|
5.6 (Scorched particles) |
- |
|
|
|
5.6 (Milk fat) |
- |
|
|
|
5.6 (Titratable acidity (lactic acid)) |
- |
|
|
|
5.6 (Total ash (on dry basis)) |
- |
|
|
|
5.6 (Milk protein in milk solids not fat) |
- |
|
|
|
5.6 (Moisture) |
- |
|
|
|
5.2 (Absence of extraneous matter, added colour and added flavour) |
- |
|
|
|
4 (Description) |
- |
|
|
|
Cl 5.4 (The flavour of the product or of the reconstituted
milk shall be pleasant and clean (see IS 10030).) |
- |
|
|
|
5.6 (Insolubility index) |
- |
|
|
|
|
Partial
|
|
- |
- |
265 |
IS 2347 (2017) |
Domestic pressure cooker - Specification (Sixth Revision) |
-
|
- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
4.1 (Capacity ) |
- |
|
|
|
6.1.1 (Pressure Regulating Device) |
- |
|
|
|
6.1.5 (Pressure Regulating Device) |
- |
|
|
|
8.1 (Air Pressure Test) |
- |
|
|
|
8.2 (Proof Pressure Test) |
- |
|
|
|
8.3 (Operating Test for Pressure Regulating Device) |
- |
|
|
|
8.4 (Test for Safety Pressure Relief Device) |
- |
|
|
|
8.5 (Bursting Pressure Test) |
- |
|
|
|
8.6.1 (Tests for Removal of Lid under Pressure For Outer Lid Cooker) |
- |
|
|
|
8.6.2 (Tests for Removal of Lid under Pressure For inner Lid Cooker) |
- |
|
|
|
6.1.2 (Pressure Regulating Device) |
- |
|
|
|
6.1.3 (Pressure Regulating Device) |
- |
|
|
|
6.1.4 (Pressure Regulating Device) |
- |
|
|
|
6.2 (Safety Relief Device) |
- |
|
|
|
6.2.1 (Safety Relief Device) |
- |
|
|
|
6.3.1 (Temperature Responsive Pressure Relief Device) |
- |
|
|
|
6.4.1 (Handles and Knobs) |
- |
|
|
|
7.1 (WORKMANSHIP AND FINISH) |
- |
|
|
|
7.2 (WORKMANSHIP AND FINISH) |
- |
|
|
|
7.3 (WORKMANSHIP AND FINISH) |
- |
|
|
|
7.4 (WORKMANSHIP AND FINISH) |
- |
|
|
|
8.14 (3 Ply Construction Cooker Body) |
- |
|
|
|
6 (CONSTRUCTION) |
- |
|
|
|
6.1 (Pressure Regulating Device) |
- |
|
|
|
6.2 NOTE (Construction-Safety Relief Device) |
- |
|
|
|
11 (Marking) |
- |
|
|
|
|
Partial
|
|
- |
- |
266 |
IS 2124 (2000) |
Sodium bicarbonate - Specification (Second Revision) |
-
|
- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
3.1 (Grade) |
- |
|
|
|
4.1 (Description) |
- |
|
|
|
4.2 (Table 1 S.no.(i)) (Total Alkalinity (as NaHCO3)) |
- |
|
|
|
4.2 (Table 1 S.no.(i)) (pH ) |
- |
|
|
|
4.2 (Table 1 S.no.(ii)) (Chlorides (as Cl)) |
- |
|
|
|
4.2 (Table 1 S.no.(iii)) (Insoluble matter) |
- |
|
|
|
4.2 (Table 1 S.no.(iv)) (Sulphates (as SO4)) |
- |
|
|
|
4.2 (Table 1 S.no.(v)) (Iron (as Fe)) |
- |
|
|
|
4.2 (Table 1 S.no.(vii)) (Arsenic (as As)) |
- |
|
|
|
4.2 (Table 1 S.no.(viii)) (Ammonium compounds (as NH4)) |
- |
|
|
|
4.2 (Table 1 S.no.(ix)) (Phosphates (as PO4)) |
- |
|
|
|
4.2 (Table 1 S.no.(x)) (Calcium and magnesium (as Ca)) |
- |
|
|
|
4.2 (Table 1 S.no.(xi)) (Copper (as Cu)) |
- |
|
|
|
4.2 (Table 1 S.no.(xii)) (Nitrates (as NO3)) |
- |
|
|
|
4.2 (Table 1 S.no.(xiii)) (Silicates (as SiOz)) |
- |
|
|
|
4.2 (Table 1 S.no.(xiv)) (Potassium (as K)) |
- |
|
|
|
4.2 (Table 1 S.no.(xv)) (Substances reducing iodine) |
- |
|
|
|
|
Partial
|
|
- |
- |
267 |
IS 14151 : Part 2 (2008) |
Irrigation equipment - Sprinkler pipes - Specification: Part 2 quick coupled polyethylene pipes and fittings (Second Revision) |
-
|
- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
6.1.2.2 ( Hydraulic Proof Test) |
- |
|
|
|
6.1.2, 6.1.2.1 ( Hydraulic Proof Test) |
- |
|
|
|
6.1.1, 6.1.1.1 (Leakage Test) |
- |
|
|
|
6.1 (Quick Coupled Pipes and Fittings) |
- |
|
|
|
4.1 .3 (Workmanship and Appearance) |
- |
|
|
|
4.1.5 (Rubber Ring) |
- |
|
|
|
Cl. 4.1.1.2.1, IS 14151 (P-1)-1999, Cl. 4, IS 2530-1963, Cl. 16 (Carbon Black Dispersion) |
- |
|
|
|
Cl.4.1 (Quick Coupled Male and Female Couplers) |
- |
|
|
|
C. 4.1.1.1.2, IS 513 (P-1)-2016, Cl. 7.3, Table-3 , Grade O (CR1) Si-Killed (Silicon Content) |
- |
|
|
|
C. 4.1.1.1.2, IS 513 (P-1)-2016, Cl. 7.3, Table-3 , Grade O (CR1) (Phosphorous Content) |
- |
|
|
|
C. 4.1.1.1.2, IS 513 (P-1)-2016, Cl. 7.3, Table-3 , Grade O (CR1) (Sulphur Content) |
- |
|
|
|
C. 4.1.1.1.2, IS 513 (P-1)-2016, Cl. 7.3, Table-3 , Grade O (CR1) (Manganese Content) |
- |
|
|
|
C. 4.1.1.1.2, IS 513 (P-1)-2016, Cl. 7.3, Table-3 , Grade O (CR1) (Carbon Content) |
- |
|
|
|
4.1.4(a) (Holding Attachments for Coupler Parts) |
- |
|
|
|
Cl 4.1.5 (Rubber rings- C)Rubber ring shall be of black colour:) |
- |
|
|
|
Cl 4.1.5 (Rubber rings- B) Change in hardness) |
- |
|
|
|
Cl 4.1.5 (Rubber rings- A)Shore hardness (Shore-A)) |
- |
|
|
|
7.2.1 (Visual and Workmanship Requirement) |
- |
|
|
|
3 (QUICK COUPLED PIPES) |
- |
|
|
|
|
Partial
|
|
- |
- |
268 |
IS 4984 (2016) |
Polyethylene pipes for water supply - Specification (Fifth Revision) |
-
|
- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
6.2.1 (6.1.1 Identification Stripes) |
- |
|
|
|
7.4 table -3 & 4 (6.1 Dimensions) |
- |
|
|
|
8.2 (Longitudinal Reversion Test) |
- |
|
|
|
8.4 ( Melt Flow Rate) |
- |
|
|
|
8.3 (Carbon black) |
- |
|
|
|
6.2 (Colour) |
- |
|
|
|
6, 6.1 (PIPE DESCRIPTION) |
- |
|
|
|
7 () |
- |
|
|
|
Clause 8.3 (Carbon Black Dispersion) |
- |
|
|
|
|
Partial
|
|
- |
- |
269 |
IS 14543 (2016) |
Packaged drinking water (Other Than Packaged Natural Mineral Water) - Specification (Second Revision) |
-
|
- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
5.3 Table-1vi (pH) |
- |
|
|
|
5.3 Table-1 v (Total dissolved solids) |
- |
|
|
|
5.3 Table-1 iv (Turbidity) |
- |
|
|
|
5.3 Table-1 iii (Taste) |
- |
|
|
|
5.3 Table-1 ii (Odour) |
- |
|
|
|
5.3 Table-1 i (Colour) |
- |
|
|
|
5.3 (Description) |
- |
|
|
|
5.2.9 (Vibrio parahaemolyticus) |
- |
|
|
|
5.2.9 (Vibrio cholera) |
- |
|
|
|
5.2.8 (Shigella) |
- |
|
|
|
5.2.8 (Salmonella) |
- |
|
|
|
5.2.7 (Yeast and Mould) |
- |
|
|
|
5.2.6 (Aerobic Microbial Count at 37°C) |
- |
|
|
|
5.2.6 (Aerobic Microbial Count at 20-22°C) |
- |
|
|
|
5.2.5 (Pseudomonas Aeruginosa) |
- |
|
|
|
5.2.4 (Sulphite Reducing Anaerobes) |
- |
|
|
|
5.2.3 (Staphylococcus Aureus) |
- |
|
|
|
5.2.3 (Faecal Streptococci) |
- |
|
|
|
5.2.2 (Coliform) |
- |
|
|
|
5.2.1 (Escherichia coli (or thermotolerant bacteria)) |
- |
|
|
|
5.3 Table-2 xi (Chloride (as Cl)) |
- |
|
|
|
5.3 Table-2 xiv (Alkaliniity (as HCO3)) |
- |
|
|
|
5.3 Table-2 i (Barium (as Ba)) |
- |
|
|
|
5.3 Table-2 ii (Copper (as Cu)) |
- |
|
|
|
5.3 Table-2 iii (Iron (as Fe),) |
- |
|
|
|
5.3 Table-2 iv (Manganese (as Mn)) |
- |
|
|
|
5.3 Table-2 viii (Zinc (as Zn)) |
- |
|
|
|
5.3 Table-2 ix (Silver (as Ag)) |
- |
|
|
|
5.3 Table-2 x (Aluminium (as Al)) |
- |
|
|
|
5.3 Table-2 xii (Selenium (as Se),) |
- |
|
|
|
5.3 Table-2 xxiii (Antimony (as Sb)) |
- |
|
|
|
5.3 Table-2 xxiv (Borates (as B)) |
- |
|
|
|
5.3 Table-3 i (Mercury (as Hg)) |
- |
|
|
|
5.3 Table-3 ii (Cadmium (as Cd)) |
- |
|
|
|
5.3 Table-3 iii (Arsenic (as As)) |
- |
|
|
|
5.3 Table-3 v (Lead (as Pb)) |
- |
|
|
|
5.3 Table-3 vi (Chromium (as Cr)) |
- |
|
|
|
5.3 Table-3 vii (Nickel (as Ni)) |
- |
|
|
|
5.3 Table-2 vi (Nitrite (as NO2)) |
- |
|
|
|
5.3 Table-2 v (Nitrate (as NO3)) |
- |
|
|
|
5.3 Table-2 xiii (Sulphate (as SO4),) |
- |
|
|
|
5.3 Table-2 xviii (Residual free chlorine) |
- |
|
|
|
5.3 Table-2 xxv (Bromates (as BrO3),) |
- |
|
|
|
5.3 Table-2vii (Fluoride (as F)) |
- |
|
|
|
5.3 Table-2 xvii (Sodium (as Na)) |
- |
|
|
|
5.3 Table-2 xvi (Magnesium (as Mg)) |
- |
|
|
|
5.3 Table-2 xv (Calcium (as Ca),) |
- |
|
|
|
Table 3, x) (Uranium) |
- |
|
|
|
5.4 ii) (Total pesticied residue) |
- |
|
|
|
5.4 i) (Dieldrin) |
- |
|
|
|
5.4 i) (Aldrin) |
- |
|
|
|
5.4 i) (Malathion) |
- |
|
|
|
5.4 i) (Methyl Paraoxon) |
- |
|
|
|
5.4 i) (Methyl Parathion) |
- |
|
|
|
5.4 i) (Atrazine) |
- |
|
|
|
5.4 i) (Alachlor) |
- |
|
|
|
5.4 i) (Isoproturon) |
- |
|
|
|
5.4 i) (Butachlor) |
- |
|
|
|
5.4 i) (2,4-D) |
- |
|
|
|
5.4 i) (phorate sulphone) |
- |
|
|
|
5.4 i) (Phorate sulphoxide) |
- |
|
|
|
5.4 i) (Phorate) |
- |
|
|
|
5.4 i) (Chlorpyrifos) |
- |
|
|
|
5.4 i) (Monocrotophos) |
- |
|
|
|
5.4 i) (Endosulfan Sulphate) |
- |
|
|
|
5.4 i) (beta-Endosulfan) |
- |
|
|
|
5.4 i) (alpha-Endosulfan) |
- |
|
|
|
5.4 i) (Delta-HCH) |
- |
|
|
|
5.4 i) (beta-HCH) |
- |
|
|
|
5.4 i) (alpha-HCH) |
- |
|
|
|
5.4 i) (Gamma-HCH (Lindane)) |
- |
|
|
|
5.4 i) (p,p DDD) |
- |
|
|
|
5.4 i) (o,p DDD) |
- |
|
|
|
5.4 i) (p,p DDE) |
- |
|
|
|
5.4 i) (o,p DDE) |
- |
|
|
|
5.4 i) (p,p DDT) |
- |
|
|
|
5.4 i) (o,p DDT) |
- |
|
|
|
5.3 Table-3 ix
(Polynuclear aromatic hydrocarbons) |
- |
|
|
|
5.3 Table-3 viii
(Polychlorinated biphenyle (PCB)) |
- |
|
|
|
5.3 Table-2 xxii (Sulphide (as H2S)) |
- |
|
|
|
5.3 Table-2 xx (Mineral oil) |
- |
|
|
|
5.3 Table-2 xxi
(Anionic surface active agents (as MBAS)) |
- |
|
|
|
5.3 Table-2 xix
(Phenolic compounds (as C6H5OH)) |
- |
|
|
|
5.4 i) (Ethion) |
- |
|
|
|
|
Partial
|
|
- |
- |
270 |
IS 1786 (2008) |
High strength deformed steel bars and wires for concretere inforcement - Specification (Fourth Revision) |
-
|
- View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
Cl. 6.1 (Nominal Size) |
- |
|
|
|
Cl 7.2 (Weight) |
- |
|
|
|
Cl. 8.1 Table 3 (Elongation, percentage) |
- |
|
|
|
Cl. 8.1 Table 3 (TS/YS ratio) |
- |
|
|
|
Cl. 8.1 Table 3 (Tensile Strength (TS)) |
- |
|
|
|
Cl. 5 (Cl.5 Mean area of ribs/unit length (Ar), ) |
- |
|
|
|
Cl. 5 (Cl. 5 - Mean projected area of transverse ribs (1/3 of Ar)) |
- |
|
|
|
Cl. 9.3, Table 4 (Bend Test ) |
- |
|
|
|
Cl.9.4 & Cl. 9.4.1 (Rebend test) |
- |
|
|
|
4.1 (Silicon %) |
- |
|
|
|
4.1 (Sulphur %) |
- |
|
|
|
4.1 (Phosphorus %) |
- |
|
|
|
4.1 (Manganese %) |
- |
|
|
|
4.1 (Carbon %) |
- |
|
|
|
Cl. 8.1 Table 3 (Yield Stress (YS)) |
- |
|
|
|
4.1 (Sulphur and phosphorous) |
- |
|
|
|
|
Partial
|
|
- |
- |