S.No. Indian Standard No. Product Grade / Type / Size / Designation etc. Testing Charges (Excl. Of Taxes) Validity Date Remark
31 IS 12586 (2021) Brazed low carbon steel gas cylinders not exceeding 13 litre water capacity Specification - - View breakup
-
- -
Test facilities are not available for the following: (1) Peel Test
32 IS 14333 (2022) Polyethylene Pipes for Sewerage and Industrial Chemicals and Effluent � Specification (First Revision) - - View breakup
-
- -
The following test facilities are not available: (1)Internal Pressure creep rupture test (2)Tensile Strength for Butt-fusion (3) Elongation at break (4) Slow Crack Growth rate test (5) Density (6) Depth of strip (7) Oxidation Induction Time (8) Overall Migration (9) Carbon Black content (10) For Size above 250 mm
33 IS 2347 (2023) DOMESTIC PRESSURE COOKER � SPECIFICATION - - View breakup
-
- -
The following test facilities are not available: (1) Material as per Clause 5.1, 5.2, 5.5, 5.6, 5.7, 5.8, 5.9, 5.10, 5.11 (2) Test for Hard Anodized Surface. (3) Test for spring-loaded mechanism (4) Test for handle and knob. (5) Electrical Pressure cooker
34 IS 14493 : Part 5 (2018) Multicore and symmetrical pair / quad cables for digital communications: Part 5 symmetrical pair / quad cables with transmission characteristics up to 1000 MHz - Horizontal floor wiring - Secal specification - - View breakup
-
- -
Test facility not available for the tests as per Cl. 6.2.3, Cl. 6.2.5, Cl. 6.2.6,Cl. 6.2.7, Cl. 6.3, Cl. 6.4.8, Cl. 6.4.8, Cl. 6.4.10, Cl. 6.5.10, Cl. 6.5.11, Cl. 6.5.14 to Cl. 6.5.21 and Cl. 7
35 IS 1165 (2022) WHOLE MILK POWDER - SPECIFICATION (Sixth Revision of IS 1165) - - View breakup
-
- -
Test facilities are not available for the following: "1. Lead, Arsenic, Aflatoxin M1, Melamine 2. As per Cl. 5.7 The pesticide residues, heavy metals, toxins (aflatoxins and other naturally occurring toxins) and contaminants, if any, in the product shall not exceed the limits as prescribed in the Food Safety and Standards (Contaminants, Toxins and Residues) Regulations, 2011.’ "
36 IS 3950 (1979) surface boxes for sluice valves - Rs.450/- View breakup
-
- -
-
37 IS 16111 (2013) Elastic bandage - - View breakup
-
- -
-
38 IS 13593 (1992) Upvc Pipe Fittings to be Used with the Upvc Pipes in the Suction and Delivery Lines Of Agricultural Pumps - - View breakup
-
- -
-
39 IS 15450 (2022) Polyethylene-aluminium-polyethylene composite pressure pipes for hot and cold water supplies Specifications first revision of IS 15450 - - View breakup
-
- -
The following test facilities are not available: (1) Density Test (2)Carbon Black Content (3) Oxidation Induction Time (4)ADHESION TEST (5) APPARENT TENSILE STRENGTH TEST (6) Hydrostatic Pressure test (Short & Long) (7)Pigment Dispersion
40 IS 3327 (1982) Specification for pedal - Operated paddy threshers (First Revision) - Rs. 7950/- excluding chemical tests. View breakup
-
- -
-
41 IS 419 (1967) Specification for putty, for use on window frames (First Revision) - 1690 View breakup
For Initial Testing = Rs. (1500+36+150) = Rs. 1686 = Rs. 1690 Only Keeping Properties Testing = Rs. (675+18+50) = Rs. 743 = Rs. 750 Preparation of Test Report = Rs. 300
- -
-
42 IS 15833 (2009) Stainless Steel Tower Bolts -specification - - View breakup
-
- -
-
43 IS 15834 (2020) Stainless Steel Sliding Door Bolts ( Aldrops ) for Use With Padlocks - Specification ( First Revision ) - - View breakup
-
- -
-
44 IS 1166 (2022) SWEETENED CONDENSED MILK, SWEETENED CONDENSED PARTLY SKIMMED MILK, SWEETENED CONDENSED SKIMMED MILK AND SWEETENED CONDENSD HIGH FAT MILK- SPECIFICATION (Third Revision of IS 1166) - - View breakup
-
- -
Test facilities are not available for the following: "1. Lead, Arsenic, Aflatoxin M1, Melamine 2. As per Cl. 5.7 The pesticide residues, heavy metals, toxins (aflatoxins and other naturally occurring toxins) and contaminants, if any, in the product shall not exceed the limits as prescribed in the Food Safety and Standards (Contaminants, Toxins and Residues) Regulations, 2011.’ "
45 IS 14887 (2014) Textiles – High density polyethylene (HDPE)/ polypropylene (PP) woven sacks for packaging of 50 kg food grains – Specification (first revision) - 19750 View breakup
-
- -
Complete facility exist except for 3.1 ( Raw Material ) and 3.2 ( Fabric)
46 IS 302 : Part 2 : Sec 3 (2007) Safety of household and similar electrical appliances: Part 2 particular requirements: Sec 3 electric iron (First Revision) - Rs.8330/- View breakup
-
- -
The following test facilities for clauses are not available: 1. Cl 24.1.2 TF for switch endurance of steam iron 2. Clause 24 Components
47 IS 10500 (2012) Drinking water - Specification (Second Revision) - - View breakup
-
- -
Test facility not available for following: 1. Cyanide 2.RAR
48 IS 14927 : Part 2 (2001) Cable Trunking and Ducting Systems for Electrical Installations : Part 2 Cable Trunking and Ducting Systems Intended for Mounting on Walls or Ceiling - - View breakup
Rs. 2694/- excluding Cable supporting test, Linear deflection test, External load test, Cover retention test and Electrical Characteristics.
- -
Test facility not available for the following: "12 pieces of 2m length "1. Cl. 12.2.1 Resistance of the Sample per Unit Length 2. Cl. 9.3.2 Torque Test , 3. Test facility for Membranes as per Cl. 9.6 and and Glands as per Cl. 9.7" "
49 IS 302 : Part 2 : Sec 14 (2009) Safety of household and similar electrical appliances: Part 2 particular requirements: Sec 14 electric kitchen machines (First Revision) - Rs.9800/- View breakup
-
- -
"Test facility available only for the following machines: Hand blender, centrifugal juicers, food mixers, citrus-fruit squeezers 1. 24.1.3 Endurance test for switches 2. 24 Components"
50 IS 366 (1991) Electric iron - Specification (Fourth Revision) - Rs.12300/- View breakup
"Hence complete testing charges for the product are Rs.16500+Rs.2025.00 =Rs.18525.00"
- -
The following test facilities for clauses are not available: 1. Cl 24.1.2 for switch endurance of steam iron 2. Cl 15 Measurement of Temperature and Average Input Power Under Load 3. Cl 17 Finish 4. Clause 24 Components as per IS 302 Part 2 Section 3
51 IS 7593 : Part 1 (1986) Specification for power - Operated pneumatic sprayer - Cum - Duster: Part 1 knapsack type (First Revision) - Please see remarks View breakup
Rs.12750/- Excluding test for prime mover (Engine) and testing charges for rubber hose as per IS:446
- -
Test facility not available for the following: One piece out of 4 pieces should be short circuited
52 IS 2548 : Part 2 (1996) Plastic seats and covers for water - Closets - Specification: Part 2 thermoplastic seats and covers (Fifth Revision) - Rs. 5700/- and testing charges as per referred Iss View breakup
-
- -
-
53 IS 3099 : Part 1 AND 2 (1992) Microscopes - Slips and slidesspecification: Part 1 microscope slips: Part 2 microscope slides (First Revision) - Rs1800.00/, Rs.1200.00/ View breakup
-
- -
Test facilities are not available for the following: (a) Optical properties
54 IS 624 (2003) Bicycles - Rims - Specification (Fourth Revision) - 2850 View breakup
Rs. 2850/- (for manufacture and finish, finish only for Ni/Cr coating thickness) + Material testing charges as per referred ISS.
- -
Test facilities are not available for the following: a) Bead Edge rim/Side straight rim-Specified Diameter and bead circumference-Cl. 3.2.1/Annex A4.1- b) Hooked/Critchet rim-Circumference of flange-Cl. 3.2.1/Annex A 4.2- d) Straight Side Rims-Bead seat angle . e) Straight Side Rims-Well Width above rim tape- Beaded Edge Rim, Side straight Rim, Hooked Rim and Crotchet Rim- f) As per Fig 22. g) Radius. h) coating thickness as per “Cl. 9.1.3
55 IS 1065 : Part 1 (2019) Stable bleaching powder - Specification: Part 1 household and industrial use (Third Revision) - - View breakup
-
- -
-
56 IS 1065 : Part 2 (2019) Stable bleaching powder - Specification: Part 2 treatment of water intended for drinking - Rs. 7,024/- View breakup
-
- -
Test facility not available for the following: 1. Pb, As, Cr , Mn ,Se,Hg,Cd
57 IS 758 (1988) Specification for cotton gauze, absorbent, non-sterilized (fourth revision) - Rs 2400/- View breakup
-
- -
-
58 IS 4985 (2021) UNPLASTICIZED PVC PIPES FOR POTABLE WATER SUPPLIES SPECIFICATION Fourth Revision - - View breakup
-
- -
The following test facilities are not available: (1) For sizes above 250 mm (2) Long Term Hydrostatic (Type Test)
59 IS 1285 (2002) Wrought aluminium and aluminium alloys - Extruded round tube and hollow sections for general engineering purposes - Specification (Third Revision) - - View breakup
-
- -
Test facilities are not available for the following: 1. Tensile Test
60 IS 367 (1993) Electric kettles and jugs for household and similar use - Specification (Fourth Revision) - 3525 .5 KW View breakup
-
- -
Test facilities are not available for the following: "1. Cl 19.102 (IS 302-2-15) Abnormal Operation 2. Cl 19.2 (IS 367) Endurance 3. Cl 20 Finish (Coating req as per IS 4827 : 1983 "