| 61 |
IS 17980 (2022) |
Maximum Power Point Tracking Efficiency of Grid Connected Photovoltaic Inverters (First Revision) |
- |
490000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl-4.1 (a)(Static MPPT efficiency) |
- |
0 |
|
- |
| Cl-4.1 (b)(Dynamic MPPT efficiency) |
- |
0 |
|
- |
| Cl-4.1 (a)(Static MPPT efficiency) |
- |
0 |
|
- |
| Cl-4.1 (b)(Dynamic MPPT efficiency) |
- |
0 |
|
- |
|
05 Apr, 2027 |
- Included w.e.f.18.06.2025 |
| 62 |
IS 4250 (2025) |
Electric Food-Mixers (Liquidizers and Grinders) and Centrifugal Juicers � Specification ( Second Revision ) |
- |
39000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl-4(General Requirements) |
- |
0 |
|
- |
| Cl-5(General Conditions for the tests) |
- |
0 |
|
- |
| Cl-6(Classification) |
- |
0 |
|
- |
| Cl-7(Marking) |
- |
0 |
|
- |
| Cl-8(Safety Requirements) |
- |
0 |
|
- |
| Cl-9(Endurance fpr motor and base assembly) |
- |
0 |
|
- |
| Cl-10.2("Grinding Coffee (for Machines that Have a
Dry Grinding Arrangement)") |
- |
0 |
|
- |
| Cl-10.3(Whisking Egg Whites (for Machines that have Whisking Egg Arrangement)) |
- |
0 |
|
- |
| Cl-10.4(Idli Batter) |
- |
0 |
|
- |
| Cl-10.5(Operational Tests for Juicers) |
- |
0 |
|
- |
| Cl-11(Temperature Withstand Test for Bowl) |
- |
0 |
|
- |
| Cl-12.1(Test for Switches) |
- |
0 |
|
- |
| Cl-13(Strength of Assembly) |
- |
0 |
|
- |
| Cl-14.2, 14.3 Table-2 (i)(Protection against access to live parts) |
- |
0 |
|
- |
| Cl-14.2, Table-2 (ii)(Power input and current) |
- |
0 |
|
- |
| Cl-14.2, 14.3 Table-2 (iii)(Leakage current and electric strength at operating temperature) |
- |
0 |
|
- |
| Cl-14.2, Table-2 (iv)(Moisture resistance) |
- |
0 |
|
- |
| Cl-14.2, Table-2 (v)(Leakage current and electric strength) |
- |
0 |
|
- |
| Cl-14.2, 14.3 Table-2 (vi)(Provision for earthing) |
- |
0 |
|
- |
| Cl-19.11.4.1(Electrostatic discharges) |
- |
0 |
|
- |
| Cl-19.11.4.3(Fast transient bursts) |
- |
0 |
|
- |
| Cl-19.11.4.4(Surge immunity test) |
- |
0 |
|
- |
|
05 Apr, 2027 |
- Included w.e.f 07.05.2025
Exclusion: Cl-19.11.4.2 (Radiated fields), Cl-19.11.4.5 (Immunity to conducted discharges), Cl-19.11.4.6 (Class 3 Voltage dips and interruptions), Cl-19.11.4.7 (Harmonics) |
| 63 |
IS 16169 (2019) |
Utility - Interconnected photovoltaic inverters - Test procedure of islanding prevention measures (First Revision) |
- |
150000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6(Test for single or multi-phase inverter) |
- |
50000 |
|
- |
| Annex A(Islanding as it applies to PV systems) |
- |
20000 |
|
- |
| Annex B(Test for independent islanding device) |
- |
10000 |
|
- |
| 6 to 6.2(Test for single or multi-phase inverter to Pass/fail criteria) |
- |
130000 |
|
- |
| 7(Documentation) |
- |
20000 |
|
- |
| 4(Testing circuit) |
- |
30000 |
|
- |
| 5(Testing equipment) |
- |
20000 |
|
- |
| Annex C(Gate blocking signal) |
- |
10000 |
|
- |
|
05 Apr, 2027 |
- Included w.e.f.30.04.2025 |
| 64 |
IS/IEC 60529 (2001) |
Degrees of protection provided by enclosures (IP Code) |
- |
22000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Cl-5(Degrees of protection against access to hazardous parts and against solid foreign objects indicated by the first characteristic numeral) |
- |
11000 |
|
Rs. 11000 per IP Numeral |
| Cl-5.1(Protection against access to hazardous parts) |
- |
11000 |
|
Rs. 11000 per IP Numeral |
| Cl-5.2(Protection against solid foreign objects) |
- |
11000 |
|
Rs. 11000 per IP Numeral |
| Cl-6(Degrees of protectlon against ingress of water indicated 'by the second characteristic numeral) |
- |
11000 |
|
Rs. 11000 per IP Numeral |
| Cl-7(Degrees of protection against access to hazardous parts indicated by the additional letter) |
- |
11000 |
|
Rs. 11000 per IP Numeral |
| Cl-8(Supplementary letter) |
- |
11000 |
|
Rs. 11000 per IP Numeral |
| Cl-10(Marking) |
- |
11000 |
|
Rs. 11000 per IP Numeral |
|
05 Apr, 2027 |
- Included w.e.f.09.04.2025 |
| 65 |
IS 17625 : Part 2 : Sec 69 (2021) |
Medical Electrical Equipment Part 2 Particular Requirements for Basic Safety and Essential Performance Section 69 Oxygen Concentrator Equipment |
- |
950000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 201.4(Power and Current) |
- |
0 |
|
- |
| 201.5(Temperature, Humidity, Dimensions, Force) |
- |
0 |
|
- |
| 201.7.1.2(Legibility of markings) |
- |
0 |
|
- |
| 201.8(Current, Voltage, Energy, Dimensions, Impedance) |
- |
0 |
|
- |
| 201.9(Mechanical dimensions, strength , torque, force) |
- |
0 |
|
- |
| 201.9.6.2.1.101(Additional requirements for audible acoustic energy) |
- |
0 |
|
- |
| 201.11(Protection against excessive temperatures and other HAZARDS) |
- |
0 |
|
- |
| 201.11.1(Maximum temperature during NORMAL USE) |
- |
0 |
|
- |
| "201.11. 1.2.2"(APPLIED PARTS not intended to supply heat to a PATIENT) |
- |
0 |
|
- |
| 201.11.2.101(Additional requirements for fire prevention) |
- |
0 |
|
- |
| 201.11.6.7(Leakage currents , dielectirc strength) |
- |
0 |
|
- |
| "201.11. 8.101"() |
- |
0 |
|
- |
| 201.11.8.101.1(TECHNICAL ALARM CONDITION for power supply failure) |
- |
0 |
|
- |
| 201.11.8.101.2(INTERNAL ELECTRICAL POWER SOURCE) |
- |
0 |
|
- |
| 201.12(Accuracy of controls and instruments and protection against hazardous outputs) |
- |
0 |
|
- |
| "201.12. 1"(Legibility of markings) |
- |
0 |
|
- |
| 201.12.1.101(Flowrate control) |
- |
0 |
|
- |
| 201.12.1.103(Accuracy of concentration) |
- |
0 |
|
- |
| 201.12.1.104(Outlet pressure) |
- |
0 |
|
- |
| 201.12.4.4.101.2(Indication of start-up period) |
- |
0 |
|
- |
| 201.12.4.102(Low oxygen concentration ALARM CONDITION) |
- |
0 |
|
- |
| 201.13(HAZARDOUS SITUATIONS and fault conditions) |
- |
0 |
|
- |
| 201.13.2.101(Additional specific SINGLE FAULT CONDITIONS) |
- |
0 |
|
- |
| 201.15(Mechanical strength, Temperature, current) |
- |
0 |
|
- |
| 201.16(Leakage currents , dielectirc strength) |
- |
0 |
|
- |
| 201.17(Electromagnetic compatibility) |
- |
0 |
|
- |
| 201.102.3(Fire RISK reduction in ACCESSORIES) |
- |
0 |
|
- |
| 202(Electromagnetic disturbances - Requirements and tests) |
- |
0 |
|
- |
| 211(Temperature, humidity, altitude, IP, Vibration, Mechanical shock) |
- |
0 |
|
- |
| 201.7(ME equipment identification, marking and documents) |
- |
0 |
|
- |
| 201.10(Protection against unwanted and excessive radiaton hazards) |
- |
0 |
|
- |
| 201.12.4.103(Filter for the delivered gas) |
- |
0 |
|
- |
| 201.12.4.4.101.1(Flowrate control) |
- |
0 |
|
- |
| 201.12.1.102(Accuracy of triggered flow) |
- |
0 |
|
- |
| 201.11.7(Biocompatibility of ME equipment and ME systems) |
- |
0 |
|
- |
| 12.11.6.6(Cleaning and disinfection of ME equipment or ME system) |
- |
0 |
|
- |
| 201.11.3.101(Additional requirements for fire enclosures of ME equipment) |
- |
0 |
|
- |
| 201.6(Classification of ME equipment and ME systems) |
- |
0 |
|
- |
| 201.6(General requirements) |
- |
0 |
|
- |
| 201.5(General requirements for testing of ME equipment) |
- |
0 |
|
- |
| 201.4(General requirements) |
- |
0 |
|
- |
| 201.7(ME equipment identification, marking and documents) |
- |
0 |
|
- |
| 201.8(Protection against electrical hazards from ME equipment) |
- |
0 |
|
- |
| 201.9(Protection against mechanical hazards of ME equipment and ME systems) |
- |
0 |
|
- |
| 201.1(Protection against unwanted and excessive radiation hazards) |
- |
0 |
|
- |
| 201.11(Protection against excessive temperatures and other hazards) |
- |
0 |
|
- |
| 201.12(Accuracy of controls and instruments and protection against hazardous outputs) |
- |
0 |
|
- |
| 201.13(Hazardous situations and fault conditions for ME equipment) |
- |
0 |
|
- |
| 201.14(Programmable electrical medical systems (PEMS)) |
- |
0 |
|
- |
| 201.14(Programmable electrical medical systems (PEMS)) |
- |
0 |
|
- |
| 201.16(ME systems) |
- |
0 |
|
- |
| 201.17(Electromagnetic compatibility of ME equipment and ME systems) |
- |
0 |
|
- |
| 201.101(Outlet connector) |
- |
0 |
|
- |
| 201.102(Requirements for parts and accessories) |
- |
0 |
|
- |
| 201.103(Functional connection) |
- |
0 |
|
- |
| 201.104(Indication of duration of operation) |
- |
0 |
|
- |
| 201.105(Integrated conserving equipment function) |
- |
0 |
|
- |
| 202(Electromagnetic disturbances – Requirements and tests) |
- |
0 |
|
- |
| 211(Requirements for medical electrical equipment and medical electrical systems used in the home healthcare environment) |
- |
0 |
|
- |
|
05 Apr, 2027 |
- Included w.e.f 25.03.2025
Exclusion: Cl 201.17 (Electromagnetic compatibility)(Radiated emission, Conducted & Radiated susceptibility), Cl 202 (Electromagnetic disturbances - Requirements and tests)(Radiated emission, Conducted & Radiated susceptibility) |
| 66 |
IS 2993 : Part 2 (2024) |
a.c. Motor Capacitors Part 2 Motor Start Capacitors ( Third Revision ) |
- |
375000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 5.1.7(Voltage test between the terminals) |
- |
5000 |
|
- |
| 5.1.8(Voltage test between terminals and case) |
- |
5000 |
|
- |
| 5.1.9(Capacitance measurement) |
- |
5000 |
|
- |
| 5.1.10(Check of dimensions) |
- |
5000 |
|
- |
| 5.1.11.1(Robustness of terminations) |
- |
5000 |
|
- |
| 5.1.11.2(Soldering) |
- |
5000 |
|
- |
| 5.1.11.3(Vibration) |
- |
5000 |
|
- |
| 5.1.12(Sealing test) |
- |
5000 |
|
- |
| 5.1.13(Endurance test) |
- |
120000 |
|
- |
| 5.1.14(Damp heat test) |
- |
120000 |
|
- |
| 5.1.15(Self-healing test) |
- |
20000 |
|
- |
| 5.1.16(Destruction test) |
- |
30000 |
|
- |
| 5.1.17.1(Ball-pressure test) |
- |
20000 |
|
- |
| 5.1.17.2(Glow-wire test) |
- |
5000 |
|
- |
| 5.1.17.3(Tracking test) |
- |
5000 |
|
- |
| 5.2(Overloads) |
- |
5000 |
|
- |
| 5.3.2(Terminals and connecting cables) |
- |
5000 |
|
- |
| 5.3.3(Earth connections) |
- |
5000 |
|
- |
| 5.3.4(Discharge devices) |
- |
5000 |
|
- |
| 5.3.5(Pollution) |
- |
5000 |
|
- |
| 5.4(Marking) |
- |
5000 |
|
- |
| 6.1.6(Voltage test between the terminals) |
- |
5000 |
|
- |
| 6.1.7(Voltage test between terminals and case) |
- |
5000 |
|
- |
| 6.1.8(Capacitance and power factor measurement) |
- |
5000 |
|
- |
| 6.1.9(Check of dimensions) |
- |
5000 |
|
- |
| 6.1.10.1(Robustness of terminations) |
- |
5000 |
|
- |
| 6.1.10.2(Soldering) |
- |
5000 |
|
- |
| 6.1.10.3(Vibration) |
- |
5000 |
|
- |
| 6.1.10.4(Fixing bolt or stud (if fitted)) |
- |
5000 |
|
- |
| 6.1.10.5(Rapid change of temperature) |
- |
5000 |
|
- |
| 6.1.11(Sealing test) |
- |
5000 |
|
- |
| 6.1.12(Endurance test) |
- |
120000 |
|
- |
| 6.1.13(Damp heat test) |
- |
120000 |
|
- |
| 6.1.14(Pressure relief test) |
- |
5000 |
|
- |
| 6.3.1(Creepage distances and clearances) |
- |
5000 |
|
- |
| 6.4(Marking) |
- |
5000 |
|
- |
| 7.2.1(Measurement of working voltage) |
- |
5000 |
|
- |
| 7.2.2(Influence of capacitance) |
- |
5000 |
|
- |
| 7.3(Checking capacitor temperature) |
- |
5000 |
|
- |
| 7.4(Checking transients) |
- |
5000 |
|
- |
| 7.5(Storage of electrolytic capacitors) |
- |
5000 |
|
- |
| Annex A(Test voltage) |
- |
5000 |
|
- |
| 5.1.1.1(General) |
- |
5000 |
|
- |
| 5.3.1(Creepage distances and clearances) |
- |
5000 |
|
- |
| 6.1.15.1(Ball-pressure test) |
- |
20000 |
|
- |
| 6.1.15.2(Glow-wire test) |
- |
25000 |
|
- |
| 6.1.15.3(Tracking test) |
- |
5000 |
|
- |
| 6.2(Overloads) |
- |
5000 |
|
- |
| 6.3.2(Terminals and connecting cables) |
- |
5000 |
|
- |
| 6.3.3(Earth connections) |
- |
5000 |
|
- |
| 6.3.4(Discharge devices) |
- |
5000 |
|
- |
| 6.3.5(Pollution) |
- |
5000 |
|
- |
| 6.1.10.4(Fixing bolt or stud (if fitted)) |
- |
5000 |
|
- |
| 5.1.10(Check of dimensions) |
- |
5000 |
|
- |
| 5.1.7(Voltage test between the terminals) |
- |
5000 |
|
- |
| 5.1.8(Voltage test between terminals and case) |
- |
5000 |
|
- |
| 5.1.9(Capacitance measurement) |
- |
5000 |
|
- |
| 5.1.10(Check of dimensions) |
- |
5000 |
|
- |
| 5.1.11.1(Robustness of terminations) |
- |
5000 |
|
- |
| 5.1.11.2(Soldering) |
- |
5000 |
|
- |
| 5.1.11.3(Vibration) |
- |
5000 |
|
- |
| 5.1.12(Sealing test) |
- |
5000 |
|
- |
| 5.1.13(Endurance test) |
- |
100000 |
|
- |
| 5.1.14(Damp heat test) |
- |
120000 |
|
- |
| 5.1.15(Self-healing test) |
- |
20000 |
|
- |
| 5.1.16(Destruction test) |
- |
30000 |
|
- |
| 5.1.17.1(Ball-pressure test) |
- |
20000 |
|
- |
| 5.1.17.2(Glow-wire test) |
- |
5000 |
|
- |
| 5.1.17.3(Tracking test) |
- |
5000 |
|
- |
| 5.2(Overloads) |
- |
5000 |
|
- |
| 5.3.2(Terminals and connecting cables) |
- |
5000 |
|
- |
| 5.3.3(Earth connections) |
- |
5000 |
|
- |
| 5.3.4(Discharge devices) |
- |
5000 |
|
- |
| 5.3.5(Pollution) |
- |
5000 |
|
- |
| 5.4(Marking) |
- |
5000 |
|
- |
| 6.1.6(Voltage test between the terminals) |
- |
5000 |
|
- |
| 6.1.7(Voltage test between terminals and case) |
- |
5000 |
|
- |
| 6.1.8(Capacitance and power factor measurement) |
- |
5000 |
|
- |
| 6.1.9(Check of dimensions) |
- |
5000 |
|
- |
| 6.1.10.1(Robustness of terminations) |
- |
5000 |
|
- |
| 6.1.10.2(Soldering) |
- |
5000 |
|
- |
| 6.1.10.3(Vibration) |
- |
5000 |
|
- |
| 6.1.10.4(Fixing bolt or stud (if fitted)) |
- |
5000 |
|
- |
| 6.1.10.5(Rapid change of temperature) |
- |
5000 |
|
- |
| 6.1.11(Sealing test) |
- |
5000 |
|
- |
| 6.1.12(Endurance test) |
- |
100000 |
|
- |
| 6.1.13(Damp heat test) |
- |
120000 |
|
- |
| 6.1.14(Pressure relief test) |
- |
5000 |
|
- |
| 6.3.1(Creepage distances and clearances) |
- |
5000 |
|
- |
| 6.4(Marking) |
- |
5000 |
|
- |
| 7.2.1(Measurement of working voltage) |
- |
5000 |
|
- |
| 7.2.2(Influence of capacitance) |
- |
5000 |
|
- |
| 7.3(Checking capacitor temperature) |
- |
5000 |
|
- |
| 7.4(Checking transients) |
- |
5000 |
|
- |
| 7.5(Storage of electrolytic capacitors) |
- |
5000 |
|
- |
| Annex A(Test voltage) |
- |
5000 |
|
- |
| 5.1.1.1(General) |
- |
5000 |
|
- |
| 5.3.1(Creepage distances and clearances) |
- |
5000 |
|
- |
| 6.1.15.1(Ball-pressure test) |
- |
20000 |
|
- |
| 6.1.15.2(Glow-wire test) |
- |
5000 |
|
- |
| 6.1.15.3(Tracking test) |
- |
5000 |
|
- |
| 6.2(Overloads) |
- |
5000 |
|
- |
| 6.3.2(Terminals and connecting cables) |
- |
5000 |
|
- |
| 6.3.3(Earth connections) |
- |
5000 |
|
- |
| 6.3.4(Discharge devices) |
- |
5000 |
|
- |
| 6.3.5(Pollution) |
- |
5000 |
|
- |
| 6.1.10.4(Fixing bolt or stud (if fitted)) |
- |
5000 |
|
- |
| 5.1.10(Check of dimensions) |
- |
5000 |
|
- |
|
05 Apr, 2027 |
- Included w.e.f 25.03.2025 |
| 67 |
IS 2993 : Part 1 (2024) |
a.c. Motor Capacitors Part 1 General - Performance, Testing and Rating - Safety Requirements - Guidance for Installation and Operation ( Third Revision ) |
- |
425000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 5.1.1(General) |
- |
0 |
|
- |
| 5.5(Tangent of loss angle) |
- |
2000 |
|
- |
| 5.7("Voltage test between terminals
") |
- |
10000 |
|
- |
| 5.8(Voltage test between terminals and case) |
- |
5000 |
|
- |
| 5.9(Capacitance measurement) |
- |
10000 |
|
- |
| 5.1(Check of dimensions) |
- |
5000 |
|
- |
| 5.11(Mechanical tests) |
- |
5000 |
|
- |
| 5.12(Sealing test) |
- |
10000 |
|
- |
| 5.13(Endurance test) |
- |
100000 |
|
- |
| 5.14(Damp heat test) |
- |
110000 |
|
- |
| 5.15(Self-healing test) |
- |
20000 |
|
- |
| 5.16(Destruction test) |
- |
25000 |
|
- |
| 5.17(Resistance to heat, fire and tracking) |
- |
20000 |
|
- |
| 5.17.1(Ball-pressure test) |
- |
2000 |
|
- |
| 5.17.2(Glow-wire test) |
- |
5000 |
|
- |
| 5.17.3(Tracking test) |
- |
2000 |
|
- |
| 6.1(Maximum permissible voltage) |
- |
2000 |
|
- |
| 6.2("Maximum permissible current
") |
- |
2000 |
|
- |
| 6.3(Maximum permissible reactive output) |
- |
2000 |
|
- |
| 7.2(Terminals and connecting cables) |
- |
5000 |
|
- |
| 7.3(Earth connections) |
- |
5000 |
|
- |
| 7.4(Discharge devices) |
- |
5000 |
|
- |
| 9.2.1(Measurements of working voltage) |
- |
5000 |
|
- |
| 9.2.2(Influence of capacitance) |
- |
5000 |
|
- |
| 9.3(Checking capacitor temperature) |
- |
5000 |
|
- |
| 9.4(Checking transients) |
- |
5000 |
|
- |
| 9.5(Leakage current) |
- |
5000 |
|
- |
| 7.1(Requirements for Creepage distances and clearances) |
- |
5000 |
|
- |
| 8(Marking) |
- |
5000 |
|
- |
| 7(Safety requirements) |
- |
5000 |
|
- |
| 5.9(Capacitance measurement) |
- |
5000 |
|
- |
| 5.1.1(General) |
- |
0 |
|
- |
| 5.5(Tangent of loss angle) |
- |
5000 |
|
- |
| 5.7("Voltage test between terminals
") |
- |
5000 |
|
- |
| 5.8(Voltage test between terminals and case) |
- |
2000 |
|
- |
| 5.9(Capacitance measurement) |
- |
2000 |
|
- |
| 5.1(Check of dimensions) |
- |
5000 |
|
- |
| 5.11(Mechanical tests) |
- |
5000 |
|
- |
| 5.12(Sealing test) |
- |
5000 |
|
- |
| 5.13(Endurance test) |
- |
100000 |
|
- |
| 5.14(Damp heat test) |
- |
110000 |
|
- |
| 5.15(Self-healing test) |
- |
20000 |
|
- |
| 5.16(Destruction test) |
- |
40000 |
|
- |
| 5.17(Resistance to heat, fire and tracking) |
- |
25000 |
|
- |
| 5.17.1(Ball-pressure test) |
- |
20000 |
|
- |
| 5.17.2(Glow-wire test) |
- |
5000 |
|
- |
| 5.17.3(Tracking test) |
- |
5000 |
|
- |
| 6.1(Maximum permissible voltage) |
- |
5000 |
|
- |
| 6.2("Maximum permissible current
") |
- |
5000 |
|
- |
| 6.3(Maximum permissible reactive output) |
- |
5000 |
|
- |
| 7.2(Terminals and connecting cables) |
- |
5000 |
|
- |
| 7.3(Earth connections) |
- |
5000 |
|
- |
| 7.4(Discharge devices) |
- |
5000 |
|
- |
| 9.2.1(Measurements of working voltage) |
- |
5000 |
|
- |
| 9.2.2(Influence of capacitance) |
- |
5000 |
|
- |
| 9.3(Checking capacitor temperature) |
- |
5000 |
|
- |
| 9.4(Checking transients) |
- |
5000 |
|
- |
| 9.5(Leakage current) |
- |
5000 |
|
- |
| 7.1(Requirements for Creepage distances and clearances) |
- |
5000 |
|
- |
| 8(Marking) |
- |
5000 |
|
- |
| 7(Safety requirements) |
- |
5000 |
|
- |
| 5.9(Capacitance measurement) |
- |
5000 |
|
- |
| 5.1.1(General) |
- |
0 |
|
- |
| 5.5(Tangent of loss angle) |
- |
5000 |
|
- |
| 5.7("Voltage test between terminals
") |
- |
5000 |
|
- |
| 5.8(Voltage test between terminals and case) |
- |
5000 |
|
- |
| 5.9(Capacitance measurement) |
- |
5000 |
|
- |
| 5.1(Check of dimensions) |
- |
5000 |
|
- |
| 5.11(Mechanical tests) |
- |
5000 |
|
- |
| 5.12(Sealing test) |
- |
5000 |
|
- |
| 5.13(Endurance test) |
- |
100000 |
|
- |
| 5.14(Damp heat test) |
- |
120000 |
|
- |
| 5.15(Self-healing test) |
- |
20000 |
|
- |
| 5.16(Destruction test) |
- |
30000 |
|
- |
| 5.17(Resistance to heat, fire and tracking) |
- |
20000 |
|
- |
| 5.17.1(Ball-pressure test) |
- |
5000 |
|
- |
| 5.17.2(Glow-wire test) |
- |
5000 |
|
- |
| 5.17.3(Tracking test) |
- |
5000 |
|
- |
| 6.1(Maximum permissible voltage) |
- |
5000 |
|
- |
| 6.2("Maximum permissible current
") |
- |
5000 |
|
- |
| 6.3(Maximum permissible reactive output) |
- |
5000 |
|
- |
| 7.2(Terminals and connecting cables) |
- |
5000 |
|
- |
| 7.3(Earth connections) |
- |
5000 |
|
- |
| 7.4(Discharge devices) |
- |
5000 |
|
- |
| 9.2.1(Measurements of working voltage) |
- |
5000 |
|
- |
| 9.2.2(Influence of capacitance) |
- |
5000 |
|
- |
| 9.3(Checking capacitor temperature) |
- |
5000 |
|
- |
| 9.4(Checking transients) |
- |
5000 |
|
- |
| 9.5(Leakage current) |
- |
5000 |
|
- |
| 7.1(Requirements for Creepage distances and clearances) |
- |
5000 |
|
- |
| 8(Marking) |
- |
5000 |
|
- |
| 7(Safety requirements) |
- |
5000 |
|
- |
| 5.9(Capacitance measurement) |
- |
5000 |
|
- |
| 5.1.1(General) |
- |
0 |
|
- |
| 5.5(Tangent of loss angle) |
- |
5000 |
|
- |
| 5.7("Voltage test between terminals
") |
- |
5000 |
|
- |
| 5.8(Voltage test between terminals and case) |
- |
5000 |
|
- |
| 5.9(Capacitance measurement) |
- |
5000 |
|
- |
| 5.1(Check of dimensions) |
- |
5000 |
|
- |
| 5.11(Mechanical tests) |
- |
5000 |
|
- |
| 5.12(Sealing test) |
- |
5000 |
|
- |
| 5.13(Endurance test) |
- |
100000 |
|
- |
| 5.14(Damp heat test) |
- |
120000 |
|
- |
| 5.15(Self-healing test) |
- |
20000 |
|
- |
| 5.16(Destruction test) |
- |
30000 |
|
- |
| 5.17(Resistance to heat, fire and tracking) |
- |
20000 |
|
- |
| 5.17.1(Ball-pressure test) |
- |
5000 |
|
- |
| 5.17.2(Glow-wire test) |
- |
5000 |
|
- |
| 5.17.3(Tracking test) |
- |
5000 |
|
- |
| 6.1(Maximum permissible voltage) |
- |
5000 |
|
- |
| 6.2("Maximum permissible current
") |
- |
5000 |
|
- |
| 6.3(Maximum permissible reactive output) |
- |
5000 |
|
- |
| 7.2(Terminals and connecting cables) |
- |
5000 |
|
- |
| 7.3(Earth connections) |
- |
5000 |
|
- |
| 7.4(Discharge devices) |
- |
5000 |
|
- |
| 9.2.1(Measurements of working voltage) |
- |
5000 |
|
- |
| 9.2.2(Influence of capacitance) |
- |
5000 |
|
- |
| 9.3(Checking capacitor temperature) |
- |
5000 |
|
- |
| 9.4(Checking transients) |
- |
5000 |
|
- |
| 9.5(Leakage current) |
- |
5000 |
|
- |
| 7.1(Requirements for Creepage distances and clearances) |
- |
5000 |
|
- |
| 8(Marking) |
- |
5000 |
|
- |
| 7(Safety requirements) |
- |
5000 |
|
- |
| 5.9(Capacitance measurement) |
- |
5000 |
|
- |
| 8(Marking) |
- |
- |
|
- |
|
05 Apr, 2027 |
- Included w.e.f.04.03.2025 |
| 68 |
IS/IEC 60947 : PART 4 : Sec 3 (2020) |
Low-Voltage Switchgear And Controlgear: Part 4-3 Contactors And Motor-Starters Semiconductor Controllers And Semiconductor Contactors For Non-Motor Loads |
- |
600000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 9.4.2.1(Test sequence V : Electrostatic discharges) |
- |
70000 |
|
- |
| 9.4.2.3(Test sequence V : Fast transients (5/50 ns)) |
- |
90000 |
|
- |
| 9.4.2.4(Test sequence V : Surges (1,2/50 µs-8/20 µs)) |
- |
90000 |
|
- |
| 9.4.2.6(Test sequence V : Voltage dips and short-time interruptions) |
- |
70000 |
|
- |
| 9.4.3.1(Test sequence V :Conducted radio-frequency emission test) |
- |
90000 |
|
- |
| 9.4.3.3(Test sequence V : Low frequency emission test) |
- |
90000 |
|
- |
|
05 Apr, 2027 |
- Included w.e.f 27.02.2025
Only Test sequence V except 9.4.2.2 Radio-frequency electromagnetic field, 9.4.3.2 Radiated radio-frequency emission test |
| 69 |
IS/IEC 60947 : Part 4 : Sec 2 (2020) |
Low-Voltage switchgear and Controlgear: Part 4-2 Contactors and Motorstarters semiconductor motor controllers starters and Soft starters |
- |
600000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 9.4.2.1(Test sequence V : Electrostatic discharges) |
- |
70000 |
|
- |
| 9.4.2.1(Test sequence V : Electrostatic discharges) |
- |
70000 |
|
- |
| 9.4.2.2(Test sequence V : Radio-frequency electromagnetic field) |
- |
90000 |
|
- |
| 9.4.2.3(Test sequence V : Fast transients (5/50 ns)) |
- |
90000 |
|
- |
| 9.4.2.4(Test sequence V : Surges (1,2/50 µs-8/20 µs)) |
- |
90000 |
|
- |
| 9.4.2.5(Test sequence V : Harmonics and commutation notches) |
- |
70000 |
|
- |
| 9.4.2.6(Test sequence V : Voltage dips and short-time interruptions) |
- |
70000 |
|
- |
| 9.4.3.1(Test sequence V : Condition for the emission tests) |
- |
90000 |
|
- |
| 9.4.3.1(Test sequence V : Conducted radio frequency emission test) |
- |
90000 |
|
- |
|
05 Apr, 2027 |
- Included w.e.f 27.02.2025
Only Test sequence V except 9.4.2.2 Radio-frequency electromagnetic field, 9.4.3.3 Radiated radio frequency emission test |
| 70 |
IS 18480 : Part 3 (2023) |
Cross Recessed Tapping Screw Part 3 Raised Countersunk Oval Head |
- |
21000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Clause. 3.0(Dimenssions.) |
- |
3000 |
|
- |
| Clause. 3.0(Thread size.) |
- |
3000 |
|
- |
| Clause. 3.0(Length) |
- |
3000 |
|
- |
| Clause. 4.0(Material) |
- |
3000 |
|
- |
| Clause. 4.0(Thread) |
- |
3000 |
|
- |
| Clause. 4.0(Cross Recess) |
- |
3000 |
|
- |
| Clause. 4.0(Tolerances) |
- |
3000 |
|
- |
| Clause. 4.0(Mechnical and functional properties.) |
- |
3000 |
|
- |
| Clause. 4.0(Finish) |
- |
3000 |
|
- |
| Clause. 4.0(Acceptability) |
- |
3000 |
|
- |
| Clause.5.0(Designation) |
- |
3000 |
|
- |
| Clause.5.0(Marking) |
- |
3000 |
|
- |
|
05 Apr, 2027 |
- Included w.e.f. 03.03.2025 |
| 71 |
IS 7485 : Part 2 (2018) |
Countersunk flat head screws (common head style) with type H or Type Z Cross Recess - Product Grade A part 2 Steel Screws of Property Class 8.8, Stainless Steel Screws and Non - Ferrous Metal Screws ( Third Revision) |
- |
19500 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 3(Dimensions) |
- |
3000 |
|
- |
| 4, table 2(Material) |
- |
3000 |
|
- |
| 4, table 2(Thread) |
- |
3000 |
|
- |
| 4, table 2(Mechanical property) |
- |
3000 |
|
- |
| 4, table 2(Tolerances) |
- |
3000 |
|
- |
| 4, table 2(Cross recess) |
- |
3000 |
|
- |
| 4, table 2(Finish - coating) |
- |
3000 |
|
- |
| 4, table 2(Surface integrity) |
- |
3000 |
|
- |
| 4, table 2(Acceptability) |
- |
3000 |
|
- |
| 5(Designation) |
- |
3000 |
|
- |
|
05 Apr, 2027 |
- Included w.e.f. 03.03.2025 |
| 72 |
IS 7485 : Part 1 (2018) |
Countersunk Flat Head Screws (Common head Style) With Type H or Type Z Cross Recess - Product Grade A Part 1 Steel Screws of Property Class 4.8 ( Third Revision) |
- |
19500 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 3(Dimensions) |
- |
3000 |
|
- |
| 4, table 2(Material) |
- |
3000 |
|
- |
| 4, table 2(General requirements) |
- |
3000 |
|
- |
| 4, table 2(Thread) |
- |
3000 |
|
- |
| 4, table 2(Mechanical property) |
- |
3000 |
|
- |
| 4, table 2(Tolerances) |
- |
3000 |
|
- |
| 4, table 2(Cross recess) |
- |
3000 |
|
- |
| 4, table 2(Finish - coating) |
- |
3000 |
|
- |
| 4, table 2(Surface integrity) |
- |
3000 |
|
- |
| 4, table 2(Acceptability) |
- |
3000 |
|
- |
| 5(Designation) |
- |
3000 |
|
- |
|
05 Apr, 2027 |
- Included w.e.f. 03.03.2025 |
| 73 |
IS 7486 (2018) |
Raised countersunk head screws (Common Head Style) with type H or type Z cross recess - Product grade A (Third Revision) |
- |
19500 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 3(Dimensions) |
- |
3000 |
|
- |
| 4, table 2(Material) |
- |
3000 |
|
- |
| 4, table 2(General requirements) |
- |
3000 |
|
- |
| 4, table 2(Thread) |
- |
3000 |
|
- |
| 4, table 2(Mechanical property) |
- |
3000 |
|
- |
| 4, table 2(Tolerances) |
- |
3000 |
|
- |
| 4, table 2(Cross recess) |
- |
3000 |
|
- |
| 4, table 2(Finish - coating) |
- |
3000 |
|
- |
| 4, table 2(Surface integrity) |
- |
3000 |
|
- |
| 4, table 2(Acceptability) |
- |
3000 |
|
- |
| 5(Designation) |
- |
3000 |
|
- |
|
05 Apr, 2027 |
- Included w.e.f. 03.03.2025 |
| 74 |
IS 7483 (2018) |
Pan Head Screws With Type H or Type Z Cross Recess - Product Grade A (Third Revision) |
- |
19500 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 3(Dimensions) |
- |
3000 |
|
- |
| 4, table 2(Material) |
- |
3000 |
|
- |
| 4, table 2(General requirements) |
- |
3000 |
|
- |
| 4, table 2(Thread) |
- |
3000 |
|
- |
| 4, table 2(Mechanical property) |
- |
3000 |
|
- |
| 4, table 2(Tolerances) |
- |
3000 |
|
- |
| 4, table 2(Cross recess) |
- |
3000 |
|
- |
| 4, table 2(Finish - coating) |
- |
3000 |
|
- |
| 4, table 2(Surface integrity) |
- |
3000 |
|
- |
| 4, table 2(Acceptability) |
- |
3000 |
|
- |
| 5(Designation) |
- |
3000 |
|
- |
|
05 Apr, 2027 |
- Included w.e.f. 03.03.2025 |
| 75 |
IS 18471 : Part 3 (2023) |
Fasteners � Cross Recessed Drilling Screws with Tapping Screw Thread Part 3 Raised Countersunk Head |
- |
20500 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Clause. 3.0(Dimenssions.) |
- |
3000 |
|
- |
| Clause. 3.0(Thread size.) |
- |
3000 |
|
- |
| Clause. 3.0(Length) |
- |
3000 |
|
- |
| Clause. 4.0(Material) |
- |
3000 |
|
- |
| Clause. 4.0(Thread) |
- |
3000 |
|
- |
| Clause. 4.0(Cross recesses) |
- |
3000 |
|
- |
| Clause. 4.0(Tolerances) |
- |
3000 |
|
- |
| Clause. 4.0(Mechnical and functional properties.) |
- |
3000 |
|
- |
| Clause. 4.0(Finish) |
- |
3000 |
|
- |
| Clause. 4.0(Acceptability) |
- |
3000 |
|
- |
| Clause.5.0(Designation) |
- |
3000 |
|
- |
| Clause.5.0(Marking) |
- |
3000 |
|
- |
|
05 Apr, 2027 |
- Included w.e.f. 03.03.2025 |
| 76 |
IS 18471 : Part 2 (2023) |
Fasteners � Cross Recessed Drilling Screws with Tapping Screw Thread Part 2 Countersunk Head |
- |
20500 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Clause. 3.0(Dimenssions.) |
- |
3000 |
|
- |
| Clause. 3.0(Thread size.) |
- |
3000 |
|
- |
| Clause. 3.0(Length) |
- |
3000 |
|
- |
| Clause. 4.0(Material) |
- |
3000 |
|
- |
| Clause. 4.0(Thread) |
- |
3000 |
|
- |
| Clause. 4.0(Cross recesses) |
- |
3000 |
|
- |
| Clause. 4.0(Mechnical and functional properties.) |
- |
5000 |
|
- |
| Clause. 4.0(Finish) |
- |
3000 |
|
- |
| Clause. 4.0(Acceptability) |
- |
3000 |
|
- |
| Clause.5.0(Designation) |
- |
3000 |
|
- |
| Clause.5.0(Marking) |
- |
3000 |
|
- |
|
05 Apr, 2027 |
- Included w.e.f. 03.03.2025 |
| 77 |
IS 18471 : Part 1 (2023) |
Fasteners � Cross Recessed Drilling Screws with Tapping Screw Thread Part 1 Pan Head |
- |
20000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Clause. 3.0(Dimenssions.) |
- |
3000 |
|
- |
| Clause. 3.0(Dimenssions.) |
- |
3000 |
|
- |
| Clause. 3.0(Thread size.) |
- |
3000 |
|
- |
| Clause. 3.0(Length) |
- |
3000 |
|
- |
| Clause. 4.0(Material) |
- |
3000 |
|
- |
| Clause. 4.0(Thread) |
- |
3000 |
|
- |
| Clause. 4.0(Cross recesses) |
- |
3000 |
|
- |
| Clause. 4.0(Mechnical and functional properties.) |
- |
3000 |
|
- |
| Clause. 4.0(Finish) |
- |
3000 |
|
- |
| Clause. 4.0(Acceptability) |
- |
3000 |
|
- |
| Clause.5.0(Designation) |
- |
3000 |
|
- |
| Clause.5.0(Marking) |
- |
3000 |
|
- |
|
05 Apr, 2027 |
- Included w.e.f. 03.03.2025 |
| 78 |
IS 18480 : Part 2 (2023) |
Cross Recessed Tapping Screws Part 2 Countersunk Flat Head |
- |
20000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Clause. 3.0(Dimenssions.) |
- |
3000 |
|
- |
| Clause. 3.0(Thread size.) |
- |
3000 |
|
- |
| Clause. 3.0(Length) |
- |
3000 |
|
- |
| Clause. 4.0(Material) |
- |
3000 |
|
- |
| Clause. 4.0(Thread) |
- |
3000 |
|
- |
| Clause. 4.0(Cross Recess) |
- |
3000 |
|
- |
| Clause. 4.0(Tolerances) |
- |
3000 |
|
- |
| Clause. 4.0(Mechnical and functional properties.) |
- |
5000 |
|
- |
| Clause. 4.0(Finish) |
- |
3000 |
|
- |
| Clause. 4.0(Acceptability) |
- |
3000 |
|
- |
| Clause.5.0(Designation) |
- |
3000 |
|
- |
| Clause.5.0(Marking) |
- |
3000 |
|
- |
|
05 Apr, 2027 |
- Included w.e.f. 03.03.2025 |
| 79 |
IS 18480 : Part 1 (2023) |
Cross Recessed Tapping Screws: Part 1 Pan Head |
- |
20500 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Clause. 3.0(Dimenssions.) |
- |
3000 |
|
- |
| Clause. 3.0(Thread size.) |
- |
3000 |
|
- |
| Clause. 3.0(Length) |
- |
3000 |
|
- |
| Clause. 4.0(Material) |
- |
3000 |
|
- |
| Clause. 4.0(Thread) |
- |
3000 |
|
- |
| Clause. 4.0(Cross Recess) |
- |
3000 |
|
- |
| Clause. 4.0(Tolerances) |
- |
3000 |
|
- |
| Clause. 4.0(Mechnical and functional properties.) |
- |
3000 |
|
- |
| Clause. 4.0(Finish) |
- |
3000 |
|
- |
| Clause. 4.0(Acceptability) |
- |
3000 |
|
- |
| Clause.5.0(Designation) |
- |
3000 |
|
- |
| Clause.5.0(Marking) |
- |
3000 |
|
- |
|
05 Apr, 2027 |
- Included w.e.f. 03.03.2025 |
| 80 |
IS 18476 (2023) |
Fasteners � Hexagon Washer Head Drilling Screws with Tapping Screw Thread |
- |
20000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Clause. 4.0(Dimenssions.) |
- |
3000 |
|
- |
| Clause. 4.0(Thread size.) |
- |
3000 |
|
- |
| Clause. 4.0(Length) |
- |
3000 |
|
- |
| Clause. 5.0(Material) |
- |
3000 |
|
- |
| Clause. 5.0(Thread) |
- |
3000 |
|
- |
| Clause. 5.0(Tolerances) |
- |
3000 |
|
- |
| Clause. 5.0(Mechnical and functional properties.) |
- |
5000 |
|
- |
| Clause. 5.0(Finish) |
- |
3000 |
|
- |
| Clause. 5.0(Acceptability) |
- |
3000 |
|
- |
| Clause.6.0(Designation) |
- |
3000 |
|
- |
| Clause.6.0(Marking) |
- |
3000 |
|
- |
|
05 Apr, 2027 |
- Included w.e.f. 03.03.2025 |
| 81 |
IS 18507 (2024) |
Drywall Screws � Specification |
- |
19800 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Clause. 4.0(Dimenssions.) |
- |
3000 |
|
- |
| Clause. 4.0(Thread size.) |
- |
3000 |
|
- |
| Clause. 4.0(Length) |
- |
3000 |
|
- |
| Clause. 5.0(Cross Recess) |
- |
3000 |
|
- |
| Clause. 5.0(Tolerances) |
- |
3000 |
|
- |
| Clause. 5.0(Surface Condition) |
- |
3000 |
|
- |
| Clause. 5.0(Surface Coating) |
- |
3000 |
|
- |
| Clause. 5.0(Acceptability) |
- |
3000 |
|
- |
| Clause.6.0(Torque Testing) |
- |
5000 |
|
- |
| Clause.7.0(Hardness) |
- |
5000 |
|
- |
| Clause.8.0(Designation) |
- |
3000 |
|
- |
| Clause.9.0(Marking) |
- |
3000 |
|
- |
| Clause. 5.0(Material) |
- |
3000 |
|
- |
|
05 Apr, 2027 |
- Included w.e.f. 03.03.2025 |
| 82 |
IS 18508 (2024) |
Chipboard Screws � Specification |
- |
20000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Clause. 4.0(Dimenssions.) |
- |
3000 |
|
- |
| Clause. 4.0(Thread size.) |
- |
3000 |
|
- |
| Clause. 4.0(Length) |
- |
3000 |
|
- |
| Clause. 5.0(Material) |
- |
3000 |
|
- |
| Clause. 5.0(Cross Recess) |
- |
3000 |
|
- |
| Clause. 5.0(Tolerances) |
- |
3000 |
|
- |
| Clause. 5.0(Surface Condition) |
- |
3000 |
|
- |
| Clause. 5.0(Surface Coating) |
- |
3000 |
|
- |
| Clause.6.0(Acceptability) |
- |
3000 |
|
- |
| Clause.6.0(Torque Testing) |
- |
5000 |
|
- |
| CClause.7.0(Hardness) |
- |
5000 |
|
- |
| Clause.8.0(Designation) |
- |
3000 |
|
- |
| Clause.9.0(Marking) |
- |
3000 |
|
- |
|
05 Apr, 2027 |
- - |
| 83 |
IS 18509 (2024) |
Cross-recessed Countersunk Head Wood Screws � Specification |
- |
20000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| Clause. 4.0(Dimenssions.) |
- |
3000 |
|
- |
| Clause. 4.0(Thread size.) |
- |
3000 |
|
- |
| Clause. 4.0(Length) |
- |
3000 |
|
- |
| Clause. 5.0(Material) |
- |
3000 |
|
- |
| Clause. 5.0(Thread And Screw ends) |
- |
3000 |
|
- |
| Clause. 5.0(Cross Recess) |
- |
3000 |
|
- |
| Clause. 5.0(Tolerances) |
- |
3000 |
|
- |
| Clause. 5.0(Surface Condition) |
- |
3000 |
|
- |
| Clause. 5.0(Surface Coating) |
- |
3000 |
|
- |
| Clause. 5.0(Acceptability) |
- |
3000 |
|
- |
| Clause.6.0(Torque Testing) |
- |
5000 |
|
- |
| Clause.7.0(Hardness) |
- |
5000 |
|
- |
| Clause.8.0(Designation) |
- |
3000 |
|
- |
| Clause.9.0(Marking) |
- |
3000 |
|
- |
|
05 Apr, 2027 |
- - |
| 84 |
IS/IEC 60947 : PART 3 (2020) |
Low-Voltage Switchgear and Controlgear: Part 3 Switches Disconnectors Switch-Disconnectors and Fuse-Combination Units |
- |
600000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 8.3(Electromagnetic compatibility tests) |
- |
600000 |
|
- |
| 8.3(Electromagnetic compatibility tests) |
- |
0 |
|
- |
|
05 Apr, 2027 |
- Included w.e.f. 06.02.2025,
Only for EMC test |
| 85 |
IS/IEC 61010 : Part 2 : Sec 020 (2016) |
Safety requirements for electrical equipment for measurement, control, and laboratory use: Part 2 - 020 particular requirements for laboratory centrifuges |
- |
250000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4(Tests) |
- |
30000 |
|
- |
| 5(Marking and documentation) |
- |
15000 |
|
- |
| 6(Protection against electric shock) |
- |
40000 |
|
- |
| 7(Protection against mechanical HAZARDS) |
- |
15000 |
|
- |
| 8(Mechanical resistance to shock and impact) |
- |
15000 |
|
- |
| 9(Protection against the spread of fire) |
- |
30000 |
|
- |
| 10(Equipment temperature limits and resistance to heat) |
- |
20000 |
|
- |
| 11(Protection against HAZARDS from fluids) |
- |
30000 |
|
- |
| 12(Protection against radiation, including laser sources, and against sonic and ultrasonic pressure) |
- |
20000 |
|
- |
| 13(Protection against liberated gases and substances, explosion and implosion) |
- |
35000 |
|
- |
| 14(Components) |
- |
10000 |
|
- |
| 15(Protection by interlocks) |
- |
10000 |
|
- |
| 16(Hazards resulting from application) |
- |
10000 |
|
- |
| 17(Risk assessment) |
- |
10000 |
|
- |
| 4(Tests) |
- |
0 |
|
- |
| 5(Marking and documentation) |
- |
0 |
|
- |
| 6(Protection against electric shock) |
- |
0 |
|
- |
| 7(Protection against mechanical HAZARDS) |
- |
0 |
|
- |
| 8(Mechanical resistance to shock and impact) |
- |
0 |
|
- |
| 9(Protection against the spread of fire) |
- |
0 |
|
- |
| 10(Equipment temperature limits and resistance to heat) |
- |
0 |
|
- |
| 11(Protection against HAZARDS from fluids) |
- |
0 |
|
- |
| 12(Protection against radiation, including laser sources, and against sonic and ultrasonic pressure) |
- |
0 |
|
- |
| 13(Protection against liberated gases and substances, explosion and implosion) |
- |
0 |
|
- |
| 14(Components) |
- |
0 |
|
- |
| 15(Protection by interlocks) |
- |
0 |
|
- |
| 16(Hazards resulting from application) |
- |
0 |
|
- |
| 17(Risk assessment) |
- |
0 |
|
- |
| 13.101(Microbiological materials) |
- |
0 |
|
- |
| 4(Tests) |
- |
0 |
|
- |
| 5(Marking and documentation) |
- |
0 |
|
- |
| 6(Protection against electric shock) |
- |
0 |
|
- |
| 7(Protection against mechanical HAZARDS) |
- |
0 |
|
- |
| 8(Mechanical resistance to shock and impact) |
- |
0 |
|
- |
| 9(Protection against the spread of fire) |
- |
0 |
|
- |
| 10(Equipment temperature limits and resistance to heat) |
- |
0 |
|
- |
| 11(Protection against HAZARDS from fluids) |
- |
0 |
|
- |
| 12(Protection against radiation, including laser sources, and against sonic and ultrasonic pressure) |
- |
0 |
|
- |
| 13(Protection against liberated gases and substances, explosion and implosion) |
- |
0 |
|
- |
| 14(Components) |
- |
0 |
|
- |
| 15(Protection by interlocks) |
- |
0 |
|
- |
| 16(Hazards resulting from application) |
- |
0 |
|
- |
| 17(Risk assessment) |
- |
0 |
|
- |
| 13.101(Microbiological materials) |
- |
0 |
|
- |
| 4(Tests) |
- |
0 |
|
- |
| 5(Marking and documentation) |
- |
0 |
|
- |
| 6(Protection against electric shock) |
- |
0 |
|
- |
| 7(Protection against mechanical HAZARDS) |
- |
0 |
|
- |
| 8(Mechanical resistance to shock and impact) |
- |
0 |
|
- |
| 9(Protection against the spread of fire) |
- |
0 |
|
- |
| 10(Equipment temperature limits and resistance to heat) |
- |
0 |
|
- |
| 11(Protection against HAZARDS from fluids) |
- |
0 |
|
- |
| 12(Protection against radiation, including laser sources, and against sonic and ultrasonic pressure) |
- |
0 |
|
- |
| 13(Protection against liberated gases and substances, explosion and implosion) |
- |
0 |
|
- |
| 14(Components) |
- |
0 |
|
- |
| 15(Protection by interlocks) |
- |
0 |
|
- |
| 16(Hazards resulting from application) |
- |
0 |
|
- |
| 17(Risk assessment) |
- |
0 |
|
- |
| 4(Tests) |
- |
0 |
|
- |
| 5(Marking and documentation) |
- |
0 |
|
- |
| 6(Protection against electric shock) |
- |
0 |
|
- |
| 7(Protection against mechanical HAZARDS) |
- |
0 |
|
- |
| 8(Mechanical resistance to shock and impact) |
- |
0 |
|
- |
| 9(Protection against the spread of fire) |
- |
0 |
|
- |
| 10(Equipment temperature limits and resistance to heat) |
- |
0 |
|
- |
| 11(Protection against HAZARDS from fluids) |
- |
0 |
|
- |
| 12(Protection against radiation, including laser sources, and against sonic and ultrasonic pressure) |
- |
0 |
|
- |
| 13(Protection against liberated gases and substances, explosion and implosion) |
- |
0 |
|
- |
| 14(Components) |
- |
0 |
|
- |
| 15(Protection by interlocks) |
- |
0 |
|
- |
| 16(Hazards resulting from application) |
- |
0 |
|
- |
| 17(Risk assessment) |
- |
0 |
|
- |
| 4(Tests) |
- |
0 |
|
- |
| 5(Marking and documentation) |
- |
0 |
|
- |
| 6(Protection against electric shock) |
- |
0 |
|
- |
| 7(Protection against mechanical HAZARDS) |
- |
0 |
|
- |
| 8(Mechanical resistance to shock and impact) |
- |
0 |
|
- |
| 9(Protection against the spread of fire) |
- |
0 |
|
- |
| 10(Equipment temperature limits and resistance to heat) |
- |
0 |
|
- |
| 11(Protection against HAZARDS from fluids) |
- |
0 |
|
- |
| 12(Protection against radiation, including laser sources, and against sonic and ultrasonic pressure) |
- |
0 |
|
- |
| 13(Protection against liberated gases and substances, explosion and implosion) |
- |
0 |
|
- |
| 14(Components) |
- |
0 |
|
- |
| 15(Protection by interlocks) |
- |
0 |
|
- |
| 16(Hazards resulting from application) |
- |
0 |
|
- |
| 17(Risk assessment) |
- |
0 |
|
- |
|
05 Apr, 2027 |
- Included w.e.f 25.03.2025
Exclusion:Cl 13.2.3 (Implosion of cathode ray tubes), Cl 13.101 (Microbiological materials) |
| 86 |
IS 367 (1993) |
Electric kettles and jugs for household and similar use - Specification (Fourth Revision) |
- |
15000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 6(Rating) |
- |
3000 |
|
- |
| 7(Classification) |
- |
3000 |
|
- |
| 8(Marking and Instruction) |
- |
3000 |
|
- |
| 9(Safety Requirements) |
- |
50000 |
|
Pretested report as per IS 302-2-15 is required |
| 11(Overall Dimensions) |
- |
3000 |
|
- |
| 12(Mass) |
- |
3000 |
|
- |
| 13(Water Capacity) |
- |
3000 |
|
- |
| 14(Time to boil one litre of water) |
- |
3000 |
|
- |
| 15(Time to boil water capacity) |
- |
3000 |
|
- |
| 16(Minimum quantity of water that can be boiled) |
- |
3000 |
|
- |
| 17(Temperature of supporting surface) |
- |
3000 |
|
- |
| 18(Thermal Efficiency) |
- |
10000 |
|
- |
| 19(Endurance) |
- |
10000 |
|
- |
| 20(Finish) |
- |
5000 |
|
- |
| Cl-9 (Cl-8 of IS 302-2-15)(PROTECTION AGAINST ACCESS TO LIVE PARTS) |
- |
10000 |
|
Pretested report as per IS 302-2-15 is required |
| Cl-9 (Cl-10 of IS 302-2-15)(POWER INPUT AND CURRENT) |
- |
10000 |
|
Pretested report as per IS 302-2-15 is required |
| Cl-9 (Cl-11 of IS 302-2-15)(HEATING) |
- |
10000 |
|
Pretested report as per IS 302-2-15 is required |
| Cl-9 (Cl-13 of IS 302-2-15)(LEAKAGE CURRENT AND ELECTRIC STRENGTH AT OPERATING TEMPERATURE) |
- |
10000 |
|
Pretested report as per IS 302-2-15 is required |
| Cl-9 (Cl-14 of IS 302-2-15)(TRANSIENT OVER VOLTAGES) |
- |
10000 |
|
Pretested report as per IS 302-2-15 is required |
| Cl-9 (Cl-15 of IS 302-2-15)(MOISTURE RESISTANCE) |
- |
20000 |
|
Pretested report as per IS 302-2-15 is required |
| Cl-9 (Cl-16 of IS 302-2-15)(LEAKAGE CURRENT AND ELECTRIC STRENGTH) |
- |
10000 |
|
Pretested report as per IS 302-2-15 is required |
| Cl-9 (Cl-17 of IS 302-2-15)(OVERLOAD PROTECTION OF TRANSFORMERS AND ASSOCIATED CIRCUITS) |
- |
10000 |
|
Pretested report as per IS 302-2-15 is required |
| Cl-9 (Cl-19 of IS 302-2-15)(ABNORMAL OPERATION) |
- |
10000 |
|
Pretested report as per IS 302-2-15 is required |
| Cl-9 (Cl-20 of IS 302-2-15)(STABILITY AND MECHANICAL HAZARDS) |
- |
10000 |
|
Pretested report as per IS 302-2-15 is required |
| Cl-9 (Cl-21 of IS 302-2-15)(MECHANICAL STRENGTH) |
- |
10000 |
|
Pretested report as per IS 302-2-15 is required |
| Cl-9 (Cl-22 of IS 302-2-15)(CONSTRUCTION) |
- |
10000 |
|
Pretested report as per IS 302-2-15 is required |
| Cl-9 (Cl-23 of IS 302-2-15)(INTERNAL WIRING) |
- |
10000 |
|
Pretested report as per IS 302-2-15 is required |
| Cl-9 (Cl-24 of IS 302-2-15)(COMPONENTS) |
- |
10000 |
|
Pretested report as per IS 302-2-15 is required |
| Cl-9 (Cl-25 of IS 302-2-15)(SUPPLY CONNECTION AND EXTERNAL FLEXIBLE CORDS) |
- |
10000 |
|
Pretested report as per IS 302-2-15 is required |
| Cl-9 (Cl-26 of IS 302-2-15)(TERMINALS FOR EXTERNAL CONDUCTORS) |
- |
10000 |
|
Pretested report as per IS 302-2-15 is required |
| Cl-9 (Cl-27 of IS 302-2-15)(PROVISION FOR EARTHING) |
- |
10000 |
|
Pretested report as per IS 302-2-15 is required |
| Cl-9 (Cl-28 of IS 302-2-15)(SCREWS AND CONNECTIONS) |
- |
10000 |
|
Pretested report as per IS 302-2-15 is required |
| Cl-9 (Cl-29 of IS 302-2-15)(CLEARANCES, CREEPAGE DISTANCES AND SOLID INSULATION) |
- |
10000 |
|
Pretested report as per IS 302-2-15 is required |
| Cl-9 (Cl-30 of IS 302-2-15)(RESISTANCE TO HEAT AND FIRE) |
- |
10000 |
|
Pretested report as per IS 302-2-15 is required |
| Cl-9 (Cl-31 of IS 302-2-15)(RESISTANCE TO RUSTING) |
- |
10000 |
|
Pretested report as per IS 302-2-15 is required |
| Cl-9 (Cl-32 of IS 302-2-15)(RADIATION, TOXICITY AND SIMILAR HAZARDS) |
- |
10000 |
|
Pretested report as per IS 302-2-15 is required |
|
05 Apr, 2027 |
- Included.w.e.f.08.01.2025
Exclusion
Cl-9 (Cl-19 of IS 302-2-15) (ABNORMAL OPERATION)
Cl-9 (Cl-24 of IS 302-2-15) (COMPONENTS) |
| 87 |
IS/IEC 80601 : Part 2 : Sec 30 (2018) |
Medical electrical equipment: Part 2 - 30 particular requirements for basic safety and essential performance of automated non - Invasive sphygmomanometers |
- |
950000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 201.4(General) |
- |
25000 |
|
- |
| 201.5(General requirements for testing ME EQUIPMENT) |
- |
30000 |
|
- |
| 201.6(Classification of ME EQUIPMENT and ME SYSTEMS) |
- |
10000 |
|
- |
| 201.7(ME EQUIPMENT identification, marking and documents) |
- |
10000 |
|
- |
| 201.8(Protection against electrical HAZARDS from ME EQUIPMENT) |
- |
40000 |
|
- |
| 201.9(Protection against mechanical HAZARDS of ME EQUIPMENT and ME SYSTEMS) |
- |
25000 |
|
- |
| 201.1(Protection against unwanted and excessive radiation HAZARDS) |
- |
25000 |
|
- |
| 201.11(Protection against excessive temperatures and other HAZARDS) |
- |
35000 |
|
- |
| 201.12(Accuracy of controls and instruments and protection against hazardous outputs) |
- |
35000 |
|
- |
| 201.13(HAZARDOUS SITUATIONS and fault conditions for ME EQUIPMENT) |
- |
30000 |
|
- |
| 201.14(PROGRAMMABLE ELECTRICAL MEDICAL SYSTEMS (PEMS)) |
- |
25000 |
|
- |
| 201.15(Construction of ME EQUIPMENT) |
- |
30000 |
|
- |
| 201.16(ME SYSTEMS) |
- |
20000 |
|
- |
| 201.17(Electromagnetic compatibility of ME EQUIPMENT and ME SYSTEMS) |
- |
350000 |
|
- |
| 201.101(Requirements for CUFFS) |
- |
100000 |
|
- |
| 201.102(Connection tubing and CUFF connectors) |
- |
100000 |
|
- |
| 201.103(Maximum inflating time) |
- |
100000 |
|
- |
| 201.105(Automatic cycling modes) |
- |
100000 |
|
- |
| 201.106(Clinical accuracy) |
- |
100000 |
|
- |
| 202(Electromagnetic disturbances – Requirements and tests) |
- |
350000 |
|
- |
| 202.8(Electromagnetic IMMUNITY requirements for ME EQUIPMENT and ME SYSTEMS) |
- |
50000 |
|
- |
| 206(Usability) |
- |
100000 |
|
- |
| 210(Requirements for the development of physiologic closed-loop controllers) |
- |
100000 |
|
- |
| 211(Requirements for medical electrical equipment and medical electrical systems used in the home healthcare environment) |
- |
100000 |
|
- |
| 212(Requirements for medical electrical equipment and medical electrical systems intended for use in the emergency medical services environment) |
- |
100000 |
|
- |
|
05 Apr, 2027 |
- included w.e.f. 21.10.2024
Exclusion
CL 201.17 (Electromagnetic compatibility of ME EQUIPMENT and ME SYSTEMS)
CL 202 (Electromagnetic disturbances – Requirements and tests) |
| 88 |
IS/ISO 80601 : Part 2 : Sec 56 (2017) |
Medical electrical equipment: Part 2 particular requirements for basic safety and essential performance: Sec 56 clinical thermometers for body temperature measurement |
- |
580000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 201.4(General requirements) |
- |
25000 |
|
- |
| 201.5(General requirements for testing of ME EQUIPMENT) |
- |
30000 |
|
- |
| 201.6(Classification of ME EQUIPMENT and ME SYSTEMS) |
- |
10000 |
|
- |
| 201.7(ME EQUIPMENT identification, marking and documents) |
- |
10000 |
|
- |
| 201.8(Protection against electrical HAZARDS from ME EQUIPMENT) |
- |
40000 |
|
- |
| 201.9(Protection against mechanical HAZARDS of ME EQUIPMENT and ME SYSTEMS) |
- |
25000 |
|
- |
| 201.10(Protection against unwanted and excessive radiation HAZARDS) |
- |
25000 |
|
- |
| 201.11(Protection against excessive temperatures and other HAZARDS) |
- |
35000 |
|
- |
| 201.10(Protection against unwanted and excessive radiation HAZARDS) |
- |
35000 |
|
- |
| 201.12(Accuracy of controls and instruments and protection against hazardous outputs) |
- |
35000 |
|
- |
| 201.13(HAZARDOUS SITUATIONS and fault conditions) |
- |
30000 |
|
- |
| 201.14(PROGRAMMABLE ELECTRICAL MEDICAL SYSTEMS (PEMS)) |
- |
35000 |
|
- |
| 201.15(Construction of ME EQUIPMENT) |
- |
30000 |
|
- |
| 201.16(ME SYSTEMS) |
- |
30000 |
|
- |
| 201.17(Electromagnetic compatibility of ME EQUIPMENT and ME SYSTEMS) |
- |
350000 |
|
- |
| 201.101(Laboratory performance requirements) |
- |
100000 |
|
- |
| 201.102(CLINICAL ACCURACY VALIDATION) |
- |
100000 |
|
- |
| 201.103("PROBES, PROBE CABLE EXTENDERS and PROBE COVERS
") |
- |
100000 |
|
- |
| 202(Electromagnetic disturbances — Requirements and tests) |
- |
150000 |
|
- |
| 208("General requirements, tests and guidance for alarm systems in medical electrical equipment
and medical electrical systems ") |
- |
100000 |
|
- |
| 212("Requirements for medical electrical equipment and medical electrical systems intended for
use in the emergency medical services environment ") |
- |
100000 |
|
- |
|
05 Apr, 2027 |
- included w.e.f.01.11.2024.
Exclusion
cl 201.17 (Electromagnetic compatibility of ME EQUIPMENT and ME SYSTEMS)
cl 202 (Electromagnetic disturbances — Requirements and tests) |
| 89 |
IS 15113 (2002) |
Clinical electrical thermometers with maximum device - Specification |
- |
250000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4.1(Metrological Requirements) |
- |
120000 |
|
- |
| 4.2(Technical Requirements) |
- |
130000 |
|
- |
| 5(Marking and Packing) |
- |
20000 |
|
- |
| 6.1.1(Probe) |
- |
120000 |
|
- |
| 6.1.2(Indicating Unit) |
- |
120000 |
|
- |
| 6.1.3(Complete Thermometer) |
- |
120000 |
|
- |
| 6.2(Verification) |
- |
120000 |
|
- |
| 4.1(Metrological Requirements) |
- |
120000 |
|
- |
| 4.2(Technical Requirements) |
- |
130000 |
|
- |
| 5(Marking and Packing) |
- |
120000 |
|
- |
| 6.1.1(Probe) |
- |
120000 |
|
- |
| 6.1.2(Indicating Unit) |
- |
120000 |
|
- |
| 6.1.3(Complete Thermometer) |
- |
120000 |
|
- |
| 6.2(Verification) |
- |
120000 |
|
- |
|
05 Apr, 2027 |
- w.e.f: 17.12.2024 Exclusion: 4.2 (Technical Requirements), 4.1 (Metrological Requirements) |
| 90 |
IS 302 : Part 2 : Sec 7 (2024) |
Safety of Household And Similar Electrical Appliances Part 2 Particular Requirements Section 7: Domestic Electric Clothes Washing Machines |
- |
90000 View breakup
-
| Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
| 4(GENERAL REQUIREMENT) |
- |
3000 |
|
- |
| 6(CLASSIFICATION) |
- |
2000 |
|
- |
| 7(MARKING AND INSTRUCTIONS) |
- |
3000 |
|
- |
| 8(PROTECTION AGAINST ACCESS TO LIVE PARTS) |
- |
4000 |
|
- |
| 10(POWER INPUT AND CURRENT) |
- |
7000 |
|
- |
| 11(HEATING) |
- |
12000 |
|
- |
| 13(LEAKAGE CURRENT AND ELECTRIC STRENGTH AT OPERATING TEMPERATURE) |
- |
8000 |
|
- |
| 14(TRANSIENT OVERVOLTAGES) |
- |
6000 |
|
- |
| 15(MOISTURE RESISTANCE) |
- |
15000 |
|
- |
| 16(LEAKAGE CURRENT AND ELECTRIC STRENGTH) |
- |
8000 |
|
- |
| 17("OVERLOAD PROTECTION OF
TRANSFORMERS AND ASSOCIATED CIRCUITS ") |
- |
5000 |
|
- |
| 17("OVERLOAD PROTECTION OF
TRANSFORMERS AND ASSOCIATED CIRCUITS ") |
- |
6000 |
|
- |
| 18(ENDURANCE) |
- |
25000 |
|
- |
| 19(ABNORMAL OPERATION) |
- |
10000 |
|
- |
| 19.11.4.1(Electrostatic discharges) |
- |
10000 |
|
- |
| 19.11.4.3(Fast transient bursts) |
- |
10000 |
|
- |
| 19.11.4.4(Surge immunity test) |
- |
10000 |
|
- |
| 19.11.4.6(Class 3 Voltage dips and interruptions) |
- |
10000 |
|
- |
| 20(STABILITY AND MECHANICAL HAZARDS) |
- |
5000 |
|
- |
| 21(MECHANICAL STRENGTH) |
- |
7000 |
|
- |
| 22(CONSTRUCTION) |
- |
8000 |
|
- |
| 23(INTERNAL WIRING) |
- |
6000 |
|
- |
| 24(COMPONENTS) |
- |
5000 |
|
- |
| 25(SUPPLY CONNECTION AND EXTERNAL FLEXIBLE CORDS) |
- |
6000 |
|
- |
| 26(TERMINALS FOR EXTERNAL CONDUCTORS) |
- |
6000 |
|
- |
| 27(PROVISION FOR EARTHING) |
- |
6000 |
|
- |
| 28(SCREWS AND CONNECTIONS) |
- |
5000 |
|
- |
| 29(CLEARANCES, CREEPAGE DISTANCES AND SOLID INSULATION) |
- |
7000 |
|
- |
| 30(RESISTANCE TO HEAT AND FIRE) |
- |
7000 |
|
- |
| 31(RESISTANCE TO RUSTING) |
- |
5000 |
|
- |
| 19.13(ABNORMAL OPERATION) |
- |
5000 |
|
- |
| 19.101(Abnormal Operation) |
- |
5000 |
|
- |
| 19.102(Abnormal Operation) |
- |
5000 |
|
- |
|
05 Apr, 2027 |
- Exclusion
Cl 19.11.4.2 to Cl 19.11.4.7
24 (COMPONENTS) |