1 |
IS 11652 (2017) |
Textiles – High density polyethylene (HDPE)/ polypropylene (PP) woven sacks for packaging of 50 kg cement – Specification (third revision) |
-
|
29380 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
4.2
(width of tape, 2.5 mm ± 0.1 mm) |
- |
500 |
|
- |
Fig. 1- Table 1- Sr. no. ii
(Ends per dm - Annex B 40 ± 2 ) |
- |
500 |
|
- |
Fig. 1- Table 1-Sr. no. iii
(Picks per dm-Annex B 40 ± 2 ) |
- |
500 |
|
- |
Fig. 1- Table 1- Sr. no. i
(Dimensions, mm (see Note )- Annex B
c) Width of gusset (e) 76 ± 10 mm
) |
- |
500 |
|
- |
Fig. 1- Table 1- Sr. no. i
(Dimensions, mm (see Note ) -Annex B
d) Width of valve (v) 100, + 10/-5 mm
) |
- |
0 |
|
- |
Fig. 1- Table 1-Sr. no. i
(Dimensions, mm (see Note )- Annex B
b) Width of sack (w) 480 ± 10 mm
) |
- |
0 |
|
- |
Fig. 1, Table 1
(i) Dimensions, mm (see Note ) -Annex B
a) Length of sack, inside (l), 710 ± 10 mm
) |
- |
0 |
|
- |
4.5(and the remaining overhang shall not be more than 5 mm after trimming.) |
- |
500 |
|
- |
4.1(Raw Material
) |
- |
500 |
|
- |
4.2
(Fabric) |
- |
500 |
|
- |
4.2
(Linear Density, 900 denier) |
- |
500 |
|
- |
4.2
(The woven fabric shall be
of mesh, 10 × 10 per inch) |
- |
0 |
|
- |
4.2
(The woven fabric shall be
of weight, 79 g/m2 ) |
- |
0 |
|
- |
4.2
(The
denier of HDPE/ PP tape used in the manufacture of
woven fabric shall be subjected to the
tolerances: a) ± 10 percent on individual value, and
) |
- |
0 |
|
- |
4.2
(The
denier of HDPE/ PP tape used in the manufacture of
woven fabric shall be subjected to the
tolerances:
b) ± 5 percent on average.
) |
- |
0 |
|
- |
4.3(Sacks) |
- |
500 |
|
- |
4.4(Seam
) |
- |
500 |
|
- |
4.4(Seam The two rows of stitches shall be separated from each other by minimum 5 mm and ) |
- |
500 |
|
- |
4.4(Seam The outer stitch shall be minimum 8 mm from the outer edge of the sacks. ) |
- |
0 |
|
- |
4.4(Seam The stitching shall be done with double fold over seam to) |
- |
500 |
|
- |
4.4(to a depth of minimum 25 mm, so that so that) |
- |
0 |
|
- |
4.4(that the stitches pass through a minimum of six layers of the fabric.) |
- |
0 |
|
- |
4.4(The number of stitches/dm shall be 14 ± 2.) |
- |
0 |
|
- |
4.4(The material used for stitching shall be HDPE/PP tape having minimum 20 percent higher denier than the tapes used
in the fabric.) |
- |
1050 |
|
- |
4.4(Seam) |
- |
0 |
|
- |
4.5(Lamination ) |
- |
1050 |
|
- |
4.6(Capacity The sack shall have the nominal filling capacity of 50 kg) |
- |
500 |
|
- |
4.7(Valve for Filling of Sacks) |
- |
500 |
|
- |
5/5.1-Table 1-Sr. no. iv(Requirements, Mass of Sack- IS 1964
a) Non-gusseted type 70 + 6%) |
- |
0 |
|
- |
5/5.6 (UV Resistance, ) |
- |
10180 |
|
- |
5/5.3-Table 1-Sr. no.v(Average breaking strength of fabric [Ravelled strip method, 325 mm × 70 mm] Min, N(kgf): -1969 (Part 1) a) Lengthwise , 900 (91.8) ) |
- |
1300 |
|
- |
5/5.3-Table 1-Sr. no.v(Average breaking strength of fabric [Ravelled strip method, 325 mm × 70 mm] Min, N(kgf): - 1969 (Part 1) b) Widthwise , 900 (91.8) ) |
- |
1300 |
|
- |
5/5.3-Table 1-Sr. no.vi(Breaking strength of top seam (Ravelled strip method), Min, - IS 9030 N (kgf) 400 (40.8)) |
- |
1300 |
|
- |
5/5.3-Table 1-Sr. no.vi(Breaking strength of bottom seam (Ravelled strip method), Min, - IS 9030 N (kgf) 400 (40.8)) |
- |
1300 |
|
- |
5/5.3-Table 1-Sr. no.vii(Elongation at break of fabric (Ravelled strip method), percent : - IS 1969 (Part1 ) a) Lengthwise 15 to 25) |
- |
0 |
|
- |
5/5.3-Table 1-Sr. no.vii(Elongation at break of fabric (Ravelled strip method), percent : - IS 1969 (Part1 ) b) Widthwise 15 to 25) |
- |
0 |
|
- |
5/5.4-Table 1-Sr. no.viii(Drop impact strength - Annex C No failure) |
- |
1100 |
|
- |
5/5.5-Table 1-Sr. no.viii(Ash content Max percent- Annex D a) For UV stabilized sacks 2.2
) |
- |
1200 |
|
- |
5/5.5-Table 1-Sr. no.viii(Ash content Max percent- Annex D b) For non-UV stabilized sacks 6
) |
- |
0 |
|
- |
5/5.6 (UV Resistance, The UV stabilized woven fabric shall have at least 50 percent retention of the original breaking strength when tested after the same has been exposed
to a) UV Radiation -Annex F ) |
- |
1300 |
|
- |
5/5.6 (UV Resistance, The UV stabilized woven fabric shall have at least 50 percent retention of the original breaking strength when tested after the same has been exposed
to b) Accelerated Weathering - Annex F ) |
- |
1300 |
|
- |
|
Complete
|
|
06 Jun, 2024 |
- |
2 |
IS 17546 (2021) |
Chlorinated polyvinyl chloride CPVC fittings for potable hot and cold water distribution supplies Specification |
-
|
163225 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
3.1(Nominal Size(DN)) |
- |
500 |
|
- |
3.2(Nominal Outside Diameter) |
- |
2000 |
|
- |
3.3(Mean Inside Diameter of Socket at Entry) |
- |
1400 |
|
- |
3.4(Mean Inside Diameter of Socket at Shoulder (Bottom)) |
- |
2000 |
|
- |
3.4(Mean Inside Diameter of Socket at Shoulder (Bottom)) |
- |
700 |
|
- |
3.5(Out-of-Roundness (Ovality)) |
- |
700 |
|
- |
3.6(Nominal Wall Thickness) |
- |
700 |
|
- |
3.7(Minimum Wall Thickness) |
- |
875 |
|
- |
3.11(Type Tests) |
- |
15800 |
|
- |
3.11(Acceptance Tests) |
- |
1100 |
|
- |
7(Dimensions of fitting) |
- |
850 |
|
- |
8.2(Opacity) |
- |
1100 |
|
- |
8.1(Visual Appearance) |
- |
1275 |
|
- |
8.3(Stress Relief Test) |
- |
2000 |
|
- |
8.4(Vicat softening Temperature) |
- |
1100 |
|
- |
8.5(Density) |
- |
1500 |
|
- |
8.6(Effect on water) |
- |
3000 |
|
- |
9(Mechanical Properties) |
- |
16900 |
|
- |
|
Complete
|
|
06 Jun, 2024 |
- |
3 |
IS 16098 Part 2 (2013) |
Structured-Wall Plastics Piping Systems for Non-Pressure Drainage and Sewerage Part 2 Pipes and Fittings with Non-Smooth External Surface, Type B |
-
|
116820 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
8.1.1 Table-10 (i)(Ring Stiffness) |
- |
1100 |
|
- |
Table -1 Cl. No. 5.1, i)(Base Density) |
- |
500 |
|
- |
Table -1 Cl. No. 5.1, ii)(Melt Flow Rate (MFR) at (190ºC, 5kg load)) |
- |
1100 |
|
- |
Table -1 Cl. No. 5.1, iii)(Thermal Stability (Oxidation Induction Test, OIT) at 200ºC) |
- |
2200 |
|
- |
8.1.1 Table-10 (ii)(Impact Strength at (0±1 ºC)) |
- |
1100 |
|
- |
" 5.1 Table-2 ", i)(Resistance to Internal Pressure 165hrs) |
- |
4800 |
|
- |
" 5.1 Table-2 ", ii)(Resistance to Internal Pressure 1000hrs) |
- |
11000 |
|
- |
8.1.1, 8.1.2 Table-10 (iii)(Ring flexibility 30% of dem) |
- |
1100 |
|
- |
6.3.1 & Table-5(Dim (min.)
E4 (min)
E5 (min.)
Socket Length) |
- |
250 |
|
- |
6.3.2(Length of Pipe) |
- |
250 |
|
- |
8.1.1 Table-10 (iv)(Creep ratio) |
- |
1100 |
|
Creep Ratio ( 1008 hrs x 25)= 25200 |
9 Table-12 (i)(Tightness of elastomeric ring seal Joint) |
- |
1000 |
|
- |
6.3.5.2(Wall Thickness(e4 min)) |
- |
25 |
|
- |
7.1(Appearance) |
- |
300 |
|
- |
7.2 Table-6 (i)(Resistance to Heating oven test at (110±2ºC for 30 minute)) |
- |
1100 |
|
- |
|
Complete
|
|
06 Jun, 2024 |
- |
4 |
IS 15532 (2004) |
Plastics crates for fruits and vegetables - Specification |
-
|
9558 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
3.2(Material) |
- |
1050 |
|
- |
3.5(Appearance and Surface Finish) |
- |
300 |
|
- |
3.3(Shape, Dimensions and Design) |
- |
500 |
|
- |
3.4(Mass) |
- |
250 |
|
- |
3.6(Dimensional Stability) |
- |
700 |
|
- |
3.7(Confluence Line Strength) |
- |
1000 |
|
- |
3.8.1(Compressive Strength (Resistance to Applied
Load)) |
- |
1100 |
|
- |
3.8.2(Resistance to Drop) |
- |
1000 |
|
- |
3.9(Resistance to Environmental Stress Cracking) |
- |
1200 |
|
- |
3.10.2(Free-Fall Test) |
- |
1000 |
|
- |
|
Complete
|
|
06 Jun, 2024 |
- |
5 |
IS 16703 (2017) |
Textiles - High density polyethylene (HDPE) polypropylene (PP) woven sacks for packaging of 25 kg polymer materials - Specification |
-
|
17268 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
5.2 Table 1(Dimensions) |
- |
200 |
|
- |
5.2 Table 1(Dimensions) |
- |
200 |
|
- |
5.2 Table 1(Dimensions) |
- |
100 |
|
- |
5.2 Table 1(Dimensions) |
- |
100 |
|
- |
5.2 Table 1(Ends per dm) |
- |
200 |
|
- |
5.2 Table 1(Picks per dm) |
- |
200 |
|
- |
5.2 Table 1(Mass of sack, Gusseted type, g - IS 1964) |
- |
500 |
|
- |
5.2 Table 1(Average breaking strength of fabric [Ravelled strip
method, 325 mm × 70mm1)] Min, N) (kgf): - IS 1969 (Part 1)) |
- |
1500 |
|
- |
5.2 Table 1(Average breaking strength of fabric [Ravelled strip
method, 325 mm × 70mm1)] Min, N2) (kgf): - IS 1969 (Part 1)) |
- |
1500 |
|
- |
5.2 Table 1(Breaking strength of bottom seam (Ravelled strip
method), Min, N) (kgf) - IS 9030) |
- |
1500 |
|
- |
5.2 Table 1(Elongation at break of fabric (Ravelled strip method),
percent : IS 1969 (Part 1)) |
- |
1500 |
|
- |
5.2 Table 1(Elongation at break of fabric (Ravelled strip method),
percent : IS 1969 (Part 1)) |
- |
1500 |
|
- |
(Clauses 4.2, 5.1, 5.2, 5.3 and 5.4) Table 1 (Ash Content ,b) For non- UV stabilized sacks) |
- |
1000 |
|
For UV Stabilized sacks and Non-UV stabilized sacks purpose |
|
Complete
|
|
06 Jun, 2024 |
- |
6 |
IS 10889 (2004) |
High density polyethylene films (First Revision) |
-
|
11525 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
5.1(Materials) |
- |
1250 |
|
- |
5.2(Black Compound) |
- |
975 |
|
- |
6.1.1(Appearance) |
- |
300 |
|
- |
6.1.2(Film Form) |
- |
300 |
|
- |
6.1.3(Odour ) |
- |
300 |
|
- |
6.1.4(Density) |
- |
500 |
|
- |
6.1.5(Melt Flow Rate) |
- |
1100 |
|
- |
6.1.6(Black Film) |
- |
300 |
|
- |
6.2.1, Table 1(Nominal Thickness) |
- |
500 |
|
- |
6.2.2, Table 2(Nominal Width) |
- |
500 |
|
- |
6.2.1, Table 1(Tolerance, Percent Grade 1 and 2) |
- |
500 |
|
- |
6.2.2, Table 2(Tolerance, Percent Grade 1 and 2) |
- |
500 |
|
- |
6.3, Table 3(Yield Tolerance) |
- |
600 |
|
- |
6.4.1(Tensile Strength at Break) |
- |
1100 |
|
- |
6.4.2(Elongation at Break) |
- |
1100 |
|
- |
6.4.3(Impact Resistance (Falling Dart)) |
- |
850 |
|
- |
6.4.3, Table 6(Average Thickness of Film) |
- |
500 |
|
- |
|
Complete
|
|
06 Jun, 2024 |
- |
7 |
IS 16647 (2017) |
Oriented unplasticized polyvinyl chloride (Pvc - O) pipes for water supply - Specification |
-
|
37025 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
9.4, annexure-E( Orientation Factor) |
- |
1000 |
|
- |
5.5( Density, g/cc) |
- |
500 |
|
- |
9 /9.1 / 27 degree centigrate(MECHANICAL CHARACTERISTICS OF PIPES9./ Resistance to Hydrostatic Pressure) |
- |
1000 |
|
- |
7.3( Opacity) |
- |
500 |
|
- |
9.2, table -11( Resistance to External Blows at 0 °C) |
- |
1000 |
|
- |
8.2 table-9( Pipe Ends) |
- |
300 |
|
- |
8.1.1, 8.1.1.2, table-3(Dimension of Pipes / Diameter/8.1.1.2 Diameter at any point) |
- |
500 |
|
- |
8.1.2, table 4 to 7(Wall Thickness) |
- |
500 |
|
- |
8.1.3 (Length, meter) |
- |
500 |
|
- |
8.2 table-9(Dimensions of Integral Socket) |
- |
500 |
|
- |
9.3 table-12( Ring Stiffness) |
- |
1100 |
|
- |
11.2 / 11.2.1( Short-Term Pressure Test for Leak Tightness of Assemblies) |
- |
1000 |
|
- |
12(b)( ELASTOMERIC SEALS) |
- |
375 |
|
- |
|
Complete
|
|
06 Jun, 2024 |
- |
8 |
IS 4985 (2000) |
Unplasticized pvc pipes for potable water supplies - Specification (Third Revision) |
-
|
15856 View breakup
-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
11.2(Resistance to External Blows at 0°C) |
- |
1000 |
|
- |
|
Complete
|
|
06 Jun, 2024 |
- |
9 |
IS 10124 : Part 3 (2009) |
Fabricated PVC-U Fittings for Potable Water Supplies - Specification Part 3 Specific Requirements for Straight Reducers |
-
|
- View breakup
Rs.1444/-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
No Record Found
|
|
Complete
|
|
06 Jun, 2024 |
Testing charges has been fixed for two years w.e.f. 30-05-2019 to 29-05-2021. |
10 |
IS 10124 : Part 5 (2009) |
Fabricated pvc - U fittings for potable water supplies - Specification: Part 5 specific requirements for equal tees (Second Revision) |
-
|
- View breakup
Rs.1444/-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
No Record Found
|
|
Complete
|
|
06 Jun, 2024 |
Testing charges has been fixed for two years w.e.f. 30-05-2019 to 29-05-2021. |
11 |
IS 10124 : Part 7 (2009) |
Fabricated pvc - U fittings for potable water supplies - Specification: Part 7 specific requirements for threaded adaptors (Second Revision) |
-
|
- View breakup
Rs.1744/-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
No Record Found
|
|
Complete
|
|
06 Jun, 2024 |
Testing charges has been fixed for two years w.e.f. 30-05-2019 to 29-05-2021. |
12 |
IS 10124 : Part 8 (2009) |
Fabricated pvc - U fittings for potable water supplies - Specification: Part 8 specific requirements for 90 degree bends (Second Revision) |
-
|
- View breakup
Rs.1444/-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
No Record Found
|
|
Complete
|
|
06 Jun, 2024 |
Testing charges has been fixed for two years w.e.f. 30-05-2019 to 29-05-2021. |
13 |
IS 10124 : Part 9 (2009) |
Fabricated pvc - U fittings for potable water supplies - Specification: Part 9 specific requirements for 60 degree bends (Second Revision) |
-
|
- View breakup
Rs.1444/-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
No Record Found
|
|
Complete
|
|
06 Jun, 2024 |
Testing charges has been fixed for two years w.e.f. 30-05-2019 to 29-05-2021. |
14 |
IS 10124 : Part 10 (2009) |
Fabricated pvc - U fittings for potable water supplies - Specification: Part 10 specific requirements for 45 degree bends (Second Revision) |
-
|
- View breakup
Rs.1444/-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
No Record Found
|
|
Complete
|
|
06 Jun, 2024 |
Testing charges has been fixed for two years w.e.f. 30-05-2019 to 29-05-2021. |
15 |
IS 10124 : Part 11 (2009) |
Fabricated pvc - U fittings for potable water supplies - Specification: Part 11 specific requirements for 40 degree bends (Second Revision) |
-
|
- View breakup
Rs.1444/-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
No Record Found
|
|
Complete
|
|
06 Jun, 2024 |
Testing charges has been fixed for two years w.e.f. 30-05-2019 to 29-05-2021. |
16 |
IS 10124 : Part 13 (2009) |
Fabricated PVC-U Fittings for Potable Water Supplies - Specification Part 13 Specific Requirements for 11¼oBends PART 12 SPECIFIC REQUIREMENTS FOR 22 ½o BENDS |
-
|
- View breakup
Rs.1444/-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
No Record Found
|
|
Complete
|
|
06 Jun, 2024 |
Testing charges has been fixed for two years w.e.f. 30-05-2019 to 29-05-2021. |
17 |
IS 10124 : Part 4 (2009) |
Fabricated pvc - U fittings for potable water supplies - Specification: Part 4 specific requirements for caps (Second Revision) |
-
|
- View breakup
Rs.1744/-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
No Record Found
|
|
Complete
|
|
06 Jun, 2024 |
Testing charges has been fixed for two years w.e.f. 30-05-2019 to 29-05-2021. |
18 |
IS 16098 Part 1 (2013) |
Structured-Wall Plastics Piping Systems for Non-Pressure Drainage and Sewerage Part 1 Pipes and Fittings With Smooth External Surface, Type A |
-
|
- View breakup
Rs.45613/- (with Elastometric sealing ring), Rs.45713/- (With solvent cement)
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
No Record Found
|
|
Complete
|
|
06 Jun, 2024 |
Testing charges has been fixed for two years w.e.f. 30-05-2019 to 29-05-2021. |
19 |
IS 9755 (2016) |
Textiles – High density polyethylene (HDPE)/ polypropylene (PP) woven sacks for packing fertilizers – Specification (fifth revision) |
-
|
- View breakup
Rs.20605/-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
No Record Found
|
|
Complete
|
|
06 Jun, 2024 |
Testing charges has been fixed for two years w.e.f. 30-05-2019 to 29-05-2021. |
20 |
IS 7834 : Part 2 (1987) |
injection moulded PVC socket fittings with solvent cement joints for water supplies: Part 2 Specific requirements for 45 degrees elbows |
-
|
- View breakup
Rs.4219/-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
No Record Found
|
|
Complete
|
|
06 Jun, 2024 |
Testing charges has been fixed for two years w.e.f. 30-05-2019 to 29-05-2021. |
21 |
IS 7834 : Part 4 (1987) |
injection moulded PVC socket fittings with solvent cement joints for water supplies: Part 4 Specific requirements for 90 degree tees |
-
|
- View breakup
Rs.4219/-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
No Record Found
|
|
Complete
|
|
06 Jun, 2024 |
Testing charges has been fixed for two years w.e.f. 30-05-2019 to 29-05-2021. |
22 |
IS 7834 : Part 5 (1987) |
Injection Moulded PVC Socket Fittings With Solvent Cement Joints for Water Supplies - Part 5 : Specific Requirements for 45 degree Tees |
-
|
- View breakup
Rs.4219/-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
No Record Found
|
|
Complete
|
|
06 Jun, 2024 |
Testing charges has been fixed for two years w.e.f. 30-05-2019 to 29-05-2021. |
23 |
IS 7834 : Part 6 (1987) |
injection moulded PVC socket fittings with solvent cement joints for water supplies: Part 6 Specific requirements for sockets |
-
|
- View breakup
Rs.4219/-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
No Record Found
|
|
Complete
|
|
06 Jun, 2024 |
Testing charges has been fixed for two years w.e.f. 30-05-2019 to 29-05-2021. |
24 |
IS 7834 : Part 7 (1987) |
injection moulded PVC socket fittings with solvent cement joints for water supplies: Part 7 Specific requirements for unions |
-
|
- View breakup
Rs.4219/-,
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
No Record Found
|
|
Complete
|
|
06 Jun, 2024 |
Testing charges has been fixed for two years w.e.f. 30-05-2019 to 29-05-2021. |
25 |
IS 7834 : Part 8 (1987) |
injection moulded PVC socket fittings with solvent cement joints for water supplies: Part 8 Specific requirements for caps |
-
|
- View breakup
Rs.4219/-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
No Record Found
|
|
Complete
|
|
06 Jun, 2024 |
Testing charges has been fixed for two years w.e.f. 30-05-2019 to 29-05-2021. |
26 |
IS 12100 (1987) |
Specification for high density polyethylene (HDPE) woven sacks for packing flour |
-
|
- View breakup
Rs.9000/-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
No Record Found
|
|
Complete
|
|
06 Jun, 2024 |
Included w.e.f 13.08.2019. Testing charges has been fixed for two years w.e.f. 13.08.2019 to 12.08.2021 |
27 |
IS 15450 (2004) |
Polyethylene/aluminium/polyethylene composite pressure pipes for hot and cold water supplies - Specification |
-
|
16069 View breakup
Product - Rs 16069 /-
Raw Material Rs 3044 /-
Aluminium – Rs 1263 /-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
8, Table-2(Dimension) |
- |
250 |
|
NIL |
10.1(Density ) |
- |
500 |
|
NIL |
10.6(Apparent tensile strength of pipe) |
- |
1600 |
|
INCLUDES SPECIMEN CHARGE |
10.7(minimum burst pressure) |
- |
1000 |
|
NIL |
Clause 10.3 table 3(Carbon black content) |
- |
925 |
|
NIL |
table 3(anti oxidant content) |
- |
0 |
|
NIL |
|
Complete
|
|
06 Jun, 2024 |
Included w.e.f 13.08.2019.
Testing charges has been fixed for two years w.e.f. 13.08.2019 to 12.08.2021 |
28 |
IS 15328 (2003) |
Unplasticized Non-Pressure Polyvinyl Chloride ( PVC -U ) Pipes for use in Underground Drainage and Sewerage Systems - |
-
|
15000 View breakup
Product - Rs 15000 /-
Raw Material Rs 900 /-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
5,5.2(Composition of the material
The material shall contain a minimum of
0.3 percent of rutile grade titanium dioxide.) |
- |
1200 |
|
NIL |
6.1,6.1.1
IS 12235 (Part 1)
Table 1(Dimension of Pipes:
Mean outside Diameter, dem) |
- |
500 |
|
NIL |
6.1,6.1.1
IS 12235 (Part 1)
Table 1(Outside Diameter at any point, de) |
- |
0 |
|
NIL |
6.1.2
IS 4985
Table 2(Wall Thickness, e ) |
- |
0 |
|
NIL |
6.1.3 (Length of Pipe) |
- |
0 |
|
NIL |
6.1.4,
Table 3(Dimensions of integral sockets and spigot ends :-
a) Elastomeric Sealing Ringsockets and
spigot ends
i)Meean inside dia. Of socket, dsm) |
- |
0 |
|
NIL |
6.1.4,
Table 3(ii) Min. depth of engagement, A. ) |
- |
0 |
|
NIL |
6.1.4
Table 3(iii) Depth of sealing Zone C ) |
- |
0 |
|
NIL |
6.1.4,
Table 3(iv) Length of spigot, l1) |
- |
0 |
|
NIL |
6.1.4,
Table 3(v) Chamfer length, H : Approx.) |
- |
0 |
|
NIL |
6.1.4.1
(wall thickness of sockets
e2 min=0.9e
) |
- |
0 |
|
NIL |
6.1.4.1
(e3min=0.75e) |
- |
0 |
|
NIL |
6.1.4,
Table 4(b) Solvent Cement Joint sockets and
spigot ends
i) Mean inside dia. Of socket, dsm) |
- |
0 |
|
NIL |
6.1.4,
Table 4(ii) Length of Solvent Cement socket, l2 ) |
- |
0 |
|
NIL |
6.1.4,
Table 4(iii) Length of spigot, l1, 100 mm Min.) |
- |
0 |
|
NIL |
6.1.4,
Table 4(iv) Chamfer length, H, 7 mm Approx.) |
- |
0 |
|
NIL |
7(Physical characteristics
) |
- |
0 |
|
NIL |
7.1(Appearance:-
) |
- |
300 |
|
NIL |
7.2(Colour ) |
- |
300 |
|
NIL |
7.3
IS 1223S
( Part 2)(Vicat Softening Temperature
When determined according to IS 1223S
( Part 2), shall not be lessthan 79°C.) |
- |
1100 |
|
NIL |
7.4
IS 1223S ( Part 5)(Longitudinal Reversion:
When tested according to the methodprescribed in IS 1223S ( Part 5), shall not exceed ± 5 percent.
The pipe shall not exhibit any blisters, bubbles or crackson completion of the test.) |
- |
1000 |
|
INCLUDES SPECIMEN CHARGE |
8(MECHANICAL CHARACTERISTICS) |
- |
0 |
|
NIL |
8.1
Annex B(Resistance to External Blows at 0ºC:
When tested according to the method prescribed in Annex B, the pipes hall have a true impact rate of not more than I0 percent.) |
- |
1400 |
|
INCLUDES SPECIMEN CHARGE |
8.2
Annex C
Table 5(Ring Stiffness:
When tested according to the method described in Annex C,the ring stiffness of the pipe shall be as stated in Table 5) |
- |
1400 |
|
INCLUDES SPECIMEN CHARGE |
8.3
IS 12235 ( Part 8/ Sec 1 )
Table 6(Resistance to internal Hydrostatic Pressure(Type Test)
a) Acceptance Test:(1h at 27 0 C)
) |
- |
850 |
|
NIL |
8.3
IS 12235 ( Part 8/ Sec 1 )
Table 6(b) Type Test:(1000h at 60 0 C)
) |
- |
11000 |
|
NIL |
9
9.1, IS 5382(JOINTS:-
a) Elastomeric Sealing Rings) |
- |
0 |
|
NIL |
9.2
IS 14182(b) Solvent cement) |
- |
0 |
|
NIL |
10(Performance requirements) |
- |
0 |
|
NIL |
10.1.1
Annex D(Internal hydrostatic pressure test for elastomeric sealing ring joints) |
- |
850 |
|
NIL |
10.1.2
Annex E(Internal negative hydrostatic pressure test (internal vacuum) for elastomeric sealing ring joints) |
- |
1000 |
|
NIL |
10.2.1(Internal hydrostatic pressure test for solvent cemented Joints) |
- |
850 |
|
NIL |
10.2.2(Internal negative hydrostatic pressure test (internal vacuum)for solvent cemented joints) |
- |
1000 |
|
NIL |
|
Complete
|
|
06 Jun, 2024 |
Included w.e.f 13.08.2019.
Testing charges has been fixed for two years w.e.f. 13.08.2019 to 12.08.2021 |
29 |
IS 14885 (2001) |
Polyethylene pipes for the supply of gaseous fuels - Specification |
-
|
45125 View breakup
Rs 45125 /-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
4.4(Colour) |
- |
300 |
|
NIL |
Table-2, 5.1(Conventional Density, IS 7328:1992) |
- |
500 |
|
NIL |
Table-2, 5.1(Melt Flow Rate, IS 2530:1963) |
- |
1100 |
|
NIL |
Table-2, 5.1(Thermal Staibility, Annex-D) |
- |
2200 |
|
NIL |
Table-2, 5.1(Resistance to gas constituents, Cl 5.5) |
- |
6250 |
|
INCLUDES CONDITIONING |
Table-2, 5.1(Pigment dispersion, Annex-E) |
- |
600 |
|
NIL |
5.2(Anti Oxidant: Cl. 17 of IS 2530) |
- |
0 |
|
NIL |
5.3(U.V.Stabilizer) |
- |
0 |
|
NIL |
6.1, Table-3(Ovality Pipe, Cl 6.3.2) |
- |
500 |
|
NIL |
6.1, Table-3(Nominal Outside Diameter of Pipes , Cl 6.3.1) |
- |
0 |
|
INCLUDED IN 6.1 |
6.2.1, Table-4(Minimum Wall Thickness, Cl.6.3, Cl.6.2.1.1, Table-5) |
- |
0 |
|
INCLUDED IN 6.1 |
6.4(Length of pipe) |
- |
0 |
|
INCLUDED IN 6.1 |
7, Table-6(Maximmn Out of Square of Each Pipe End) |
- |
0 |
|
INCLUDED IN 6.1 |
8.1(Hydraulic Charactristics, Annex-A) |
- |
20300 |
|
INCLUDES SPECIMEN CHARGE |
8.2(Reversion Test. Annex-C) |
- |
700 |
|
NIL |
8.3(Density, Annex A of IS 7328) |
- |
500 |
|
NIL |
8.4(Melt Flow Rate (MFR), IS 2530) |
- |
1100 |
|
NIL |
8.5(Thermal Stability to Oxidation, Annex-D) |
- |
2200 |
|
NIL |
8.7(Tensile yield strength, Annex-J) |
- |
1350 |
|
NIL |
8.7(Elongation at break, Annex-J) |
- |
1350 |
|
NIL |
8.8(Resistance to Weathering, Annex-F) |
- |
12550 |
|
NIL |
8.9(Squeeze off, Annex-G) |
- |
6100 |
|
NIL |
8.6 & Table-2(Volatile Content: Annex-H of IS 14885) |
- |
700 |
|
NIL |
8.5 & Table-2(Thermal Stability to Oxidation, Annex-D of IS 14885) |
- |
2200 |
|
NIL |
|
Complete
|
|
06 Jun, 2024 |
Included w.e.f 13.08.2019.
Testing charges has been fixed for two years w.e.f. 13.08.2019 to 12.08.2021 |
30 |
IS 14735 (1999) |
Unplasticized Polyvinyl Chloride (UPVC) Injection Moulded Fittings for Soil and Waste Discharge System for Inside and Outside Buildings Including Ventilation and Rain Water System - |
-
|
7438 View breakup
Product - Rs 7438 /-
Material Rs 1725 /-
Rubber Ring – Rs 1069 /-
Clause No. |
Exclusion |
Testing Charges (Excl. Of Taxes) |
Effective Date |
Remark |
19(Marking) |
- |
0 |
|
NIL |
3(Type of Fitting) |
- |
0 |
|
NIL |
4(Size Designation) |
- |
0 |
|
NIL |
5(Colour of fittings) |
- |
300 |
|
NIL |
7.1,Table 1(Wall thickness) |
- |
500 |
|
NIL |
7.2 ,Table 2&3(Socket Dimensions) |
- |
0 |
|
INCLUDED IN 7.1 |
7.3(Dimensions of waste trap(Nahani Trap) |
- |
0 |
|
NIL |
8(Sealing Rings) |
- |
1425 |
|
NIL |
10(Workmanship) |
- |
300 |
|
NIL |
11(Design requirements) |
- |
0 |
|
NIL |
11.1(Solvent cement type or Rubber ring type) |
- |
0 |
|
NIL |
11.2(Socket and spigot configeration) |
- |
0 |
|
NIL |
11.4,Table 5(Vent cowl) |
- |
0 |
|
NIL |
11.5,Table 6(Pipe Clips) |
- |
0 |
|
NIL |
12(Physical test requirements) |
- |
0 |
|
NIL |
12.1(Visual appearance) |
- |
300 |
|
NIL |
12.2(Stress relief test) |
- |
700 |
|
NIL |
12.3(Vicat softening tempewrature) |
- |
1100 |
|
NIL |
Cl.13, IS 12235 (P-7)-2004, (Resistance to Sulphuric Acid) |
- |
2500 |
|
INCLUDES CONDITIONING CHARGE |
Cl.14, Annex A(Titanium Di-Oxide Content) |
- |
1200 |
|
NIL |
Cl.15, Annex B(Sulphated Ash Content) |
- |
850 |
|
NIL |
16(Mechanical Properties) |
- |
0 |
|
NIL |
16.1(Impact test) |
- |
1000 |
|
NIL |
17(Watet tightness of joint) |
- |
1000 |
|
NIL |
|
Complete
|
|
06 Jun, 2024 |
Included w.e.f 13.08.2019.
Testing charges has been fixed for two years w.e.f. 13.08.2019 to 12.08.2021 |